Loading...
Building Plans - Lot 20; < ; EL o UPPER FLOOR PLAN MAIN FLOOR: UPPER r-LOOR: TOTAL: 6ARA6r= : 1562 50. PT. 1642 50. FT. 5004 50. PT. 640 50. PT. PORCH: 8"? 50. PT. PORCH: 140 50. PT COPYRIGHT 2012 Landmark Design Inc. ALL RIGHTS FrESERVE0 MAIN FLOOR PLAN GENERAL NOTES: 1. ALL WORK TO BE IN CONFORMANCE WITH 2O18 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE DRAIN. 6. SHOWERHEADS t KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.P.M FLOW. 1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET TO BE SAFETY GLASS. B. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS 9. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. =SMOKE ALARI`1-CAR50N MONOXIDE COMBO. C.M. 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR E OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2018 IRC E WA. STATE AMENDMENTS SEC R315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC R403B3. 12. ALL DUCTS t EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303B2. 14. GAS PIPING IS TO BE PROTECTED PER G24151. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC E CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE E WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 1-1. DRYER DUCT SPECIFIED LENGTH PER SEC M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 16. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2018 WSEC TABLE R402.4.1.1. IS. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. Rro023(TWO-STORY/ BALLOON FRAME WALLS) UTILITY ROOM NOTES/MAKE UP AIR: PER IRC G243S 1. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS :IT' DOOR 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A ER THAN PERMANENT LABEL OR TAG. THE LABEL OR I TOP OF TAG SHALL BE LOCATED WITHIN 6 FT OF THE M3.1) EXHAUST DUCT CONNECTION PER G2439.1.5. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243S.5. E - = 100 SQ INCH TRANSFER GRILL INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. XTERIOR STAIRWAY ILLUMINATION PER SEC R303B I EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. z °0 M °y z ♦♦♦ E yN E � SON A gym yn Ao ♦ N.N.. 0 �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: L2-3006-3L Date: 2-20-24 0j, 4" GONG. SLAB TO GONG. CONTACT W1 4PPROVED MEMBRANE STUB 04 BARS INTO GONG. SLAB G 18" O.G. A FOUND AT I ON AT FAT 10 NTS FOUNDATION PLAN I/'4u- 1 1_Ou STHD EDGE DISTANCE 1-1/2' MIN BUILDER TO DETERMINE IF STHD OR STHD/RJ IS APPROPRIATE. COPYRIGHT 2009 Landmark Design Inc. ALL RIGHTS RESERVED 4' 0 SCHED. 40 STL. I 4-3/8'X3' ANCHOR Bc (SIMPSON TITAN HD C 4' CONCRETE SLAB 1 18'x18'x6' SIDE VIEW CONCRETE FOOTING SIMPSON TITANOHE) OR EQ) 8' 0 3/16 cA it1/2'XS'XS' 0 I. TOP VIEW USE 3' x 3' x 1/4' GALVANIZED STEEL SQUARE PLATE WASHERS FOR ALL ANCHOR BOLTS VEHICLE IMPACT BARRIER DETAIL FOUNDATION NOTES: I. ALL FOOTINGS TO BEAR ON FIRM UNDISTURBED SOIL. 2. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 3. ALL BEAMS TO BE 4x10 DFL 02 ON 4x4 POSTS (4x6 AT SPLICES) ON 24' DIA. x 6' CONC. PADS UNLESS NOTED OTHERWISE. 4. ALL POSTS TO BE ANCHORED AGAINST LATERAL MOVEMENT. 5. SOLID BLOCK AT ALL POINT LOADS FROM ABOVE. 6. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AT EACH END AND AT EACH SUPPORT, BY SOLID BLOCKING OR BY ANOTHER APPROVED METHOD. -I. PROVIDE MINIMUM 18'-24' CRAWL ACCESS. *CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 8. PROVIDE CRAWL SPACE VENTILATION PER IRC SECTION R408. *FOUNDATION VENTS SHALL BE PLACED SO THAT THE TOP OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. S. INTERIOR GRADE OF CRAWL SPACE SHALL BE SLOPED TO DRAIN AND INSURE THE REMOVAL OF WATER 10.PREVENT WOOD TO GONG. CONTACT W/CONT. FLASHING OR APPROVE MEMBRANE. 11. INDICATES 'SIMPSON' HOLDDOWN. 12. aSEE SHEARWALL SCHEDULE FOR ANCHOR BOLT SIZE 4 SPACING (SHT 51.0). VENTILATION CRAWL SPACE VENTILATION TOTAL NET FREE AREA REQ'D 1362/300 a 4B4 SQ. FT. PROVIDE SCREENED VENTS FOR VENTILATION z T� M °y z ♦♦♦ E yN E � SON A gym oo yn CO z00 ♦ N.N.. 0 �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2-3006-3L Date: 2-20-24 -1 VENTS IREa D J LSTA36 - HOR 4 SILL TO MATCH ROOF SHEATHING FRAMING NOTES: SECOND FLOOR FRA�4 I 6 FLAIL' I. ALL MULTIPLE JOISTS OR BEAMS MUST BE BOTH GLUED AND NAILED W/8d NAILS m 24' O.C. NAILED TOP < BOTTOM STAGGERED EACH SIDE. 2. ALL HEADERS TO BE 4x8 OF 02, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS t WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 3. SOLID BLOCK BENEATH ALL POINT LOADS FROM ABOVE. 4. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AND SUPPORTED BY SOLID BLOCKING OR BY ANOTHER APPROVED METHOD. 5. MSTC 40 STRAPS PER STRUCTURAL, UNLESS NOTED OTHERWISE 6. ,_ A I REFER TO SHEAR WALL SCHEDULE. 1. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE (OBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023 (TWO STORY/BALLOOON FRAME WALLS) 1/411= 1 I_Ou :ONT. DBL. TOP PLATE Z-10 KI&ID INSULATION 5HADED AREA) 4X HEAVER KIN& STUD EXTERIOR PLYWOOD TRIMMER HEAZ�ER/I NSULAT I ON nETA I L NTS 6X6 PT POST W/ CAP PBZ BASE 1EAM 1EAM ROOF FRAMING NOTES: I. ALL HEADERS TO BE 4x8 OF "2, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS 4 WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 2. ALL OTHER TRUSSES: • SHALL CARRY MANUFACTURERS STAMP. • SHALL HAVE DESIGN DETAILS AND SPECIFICATIONS ON SITE FOR FRAME INSPECTION. SHALL BE INSTALLED AND BRACED PER MANUFACTURERS SPECIFICATIONS PER IRC SEC. 502.112 AND 802.103 AS WELL AS THE TRUSS INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. 3. NO TRUSS SHALL BE FIELD -MODIFIED WITHOUT PRIOR CONSENT OF THE TRUSS ENGINEER AND THE BUILDING DEPARTMENT. 4. PROVIDE ATTIC ACCESS AT A MINIMUM OF 22'x3O' PER IRC SEC. *ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 5. PROVIDE ATTIC VENTILATION PER IRC SEC. R806. ALL FRAMING TO COMPLY WITH IRC SEC R802. 6, aA REFER TO SHEAR WALL SCHEDULE. -1. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE (OBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023 (TWO STORY/BALLOOON FRAME WALLS) MANUFACTURED TRUSSES 'OP PLATE MANUFACTURER'S INSTALLATION INSTRUCTIONS BLOCKING SHALL BE AVAILABLE ON SITE AT TIME OF INSPECTION, FOR THE INSPECTORS USE AND REFERENCE VENTILATION GAL CUL AT I ONS 4 REQUIREMENT& 409*4 NOT MORE THAN 50% OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF ED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE OF REQUIRED VENTILATION PROVIDED BY EAVE VENTING. ION REQUIRED PER SEC. R806.1 - ENCLOSED ATTICS AND ENCLOSED RAFTER :ORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING 5 PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS EVE A LEAST DIMENSIONS OF 1/16' INCH MINIMUM AND 1/4' INCH MAXIMUM. VENTILATION 5 HAVING A LEAST DIMENSION LARGER THAN 1/4' SHALL BE PROVIDED WITH ON -RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL NINGS HAVING A LEAST DIMENSION OF 1/16' MINIMUM AND 1/4' MAXIMUM. OPENINGS IN aMING MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION R8021. VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR SENT AREA PER SEC. R8062 - THE MINIMUM NET FREE VENTILATION AREA SHALL BE 'HE AREA OF THE VENTED SPACE. > INSULATION CLEARANCE PER SEC. R8063 - WHERE EAVE OR CORNICE VENTS ARE INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR NOT LESS THAN A 1-INCH 4ALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE 4 OF THE VENT. EET N2 FOR ROOF VENTILATION CALCULATIONS ,AND LOCATIONS R302.12.1 MATERIALS. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2' GYPSUM BOARD, 3/6' WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBER UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SF, SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN GWB s CEILING TRUSS EDGE VIEW TRUSS LENGTH VIEW TRUSS EDGE VIEW GARAGE WALL TRUSS TOP VIEW 9 GARAGE WALL SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN GWB im CEILING SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN LATERAL BLOCKING PANELS w/ DRAFTSTOPPING GWB is CEILING FLOOR TRUSS PER PLAN GARAGE WALL BELOW LATERAL BLOCKING PANELS w/ DRAFTSTOPPING SCALE: 1/2' ■ V-0' � 1;)RAF757010P I NG Dr=iA I L � TYP TO 3x BLOCKING. 8 (TYP. 2 PLACES) 2 0 ROOF FRAMING PLAN 1/4 11 /411 = 1 I—O II NOTE - FASTENERS FOR TREATED WOOD TO BE HOT -DIPPED GALVANIZED, STAINLESS STEEL, SILICONE, BRONZE OR COPPER A24-BM TO 3X OCKING ROOF OVERFRAME NOTES: IRC SEC R8023 1. RAFTERS SHALL BE FRAMED TO 2x RIDGE BOARD PER PLAN. RIDGE BOARD SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER AT ALL VALLEYS AND HIPS THERE SHALL BE A 2x VALLEY OR HIP RAFTER AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER (FULL COVERAGE AT RIDGE, HIPS AND VALLEYS). STUD NOTCHING AND BORING - BEARING OR EXTERIOR WALL NOTCH 25%, BORING 40%. - 60% BORING IF DOUBLED d LESS OR EQUAL SUCCESSIVE STUDS. - NON -BEARING MAXIMUM NOTCH 40%, BORING 60%. - HOLES NO CLOSER THAN 5/8 INCH TO FACE OF STUD. 00 V 1 �00 � as, Z a W E Go 2-n A gym z =003 A4 M h N� 0 �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2-3006-3L Date: 2-20-24 �I v 2x6 02 OF STUDS 16' O.C. ATTACH STUDS TO TOP 4 BOTTOM PLATE WITH (3) 16d FRAMING NAILS. CONSTRUCT TOP PLATE OF (2) STUDS INSTALLED HORIZ. AT THE TOP OF THE GYPSUM WALL ASSEMBLY AND THE BOTTOM PLA' A SINGLE STUD. INSTALL 2x6 WOOD STUC HORIZ. AS CROSS -BRACING POSITIONED MID -HEIGHT OF THE WALL. Na' TYPE 'X' GWB APPLIED VERTICALLY W/ HORIZONTAL JOINTS BLOCKED AND FASTENED W/6d CEMENT COATED llka' CUP -HEAD DRYWALL NAILS W/.0515' SHANK DIA. 4 1/4' HEAD DIA. SPACED 8' O.C. ALONG STUDS 4 PLATES. EXPOSED FASTENER HEADS AND WALLBOARD JOINTS MUST BE TREATED W/(2) COATS OF GYPSUM COMPOUND. A MIN. 2' PAPER, PLASTIC OR FIBERGLASS TAPE MUST BE SOLID TIGHT FITTING TRUSS BLOCKING (SEE DETAIL THIS SHEET FOR SAVE VENTING) 2x8 FASCIA BOARD N6' L"FLAMEBLOCK®FIRE-RATED OSB SHEATHING W/IBmm PYROTITE LAMINATE APPLIED TO ONLY ONE FACE OF WOOD PANEL. SHEATHING MUST BE INSTALLED VERTICALLY W/HORIZONTAL JOINTS BLOCKED 4 W/PYROTITE LAMINATE FACING THE OUTSIDE 4 MUST BE ATTACHED TO THE STUDS W/1"I8' 6d COMMON NAILS SPACED 6' O.G. AROUNL PERIMETER 4 12' O.0 IN THE FIELD. 511/2' THICK NOMINAL 3 PCF DENSITY UNFACED MINERAL FIBER BATT INSULATION FRICTION FIT BETWEEN THE WOOD STUDS, CROSS -BRACING 4 TOP/BOTTOM PLATES. WEATHER BARRIER FASTENED OVER THE SHEATHING USING SUFFICIENT FASTENERS TO PREVENT AIR POCKETS IN THE WRAP EMBEDDED IN FIRST LAYER OF EXTERIOR WALL COVERING: COUMPOUND OVER WALLBOARD JOINTS. 1. FIBER CEMENT BOARD 2. TI-11 SIDING 3. WOOD FIBER PANEL 4. CEMENT PLASTER (STUCCO) 5. STEEL SIDING DESIGN (ICC-ES REPORT - ESR-1365) WALL TYPE3 4 4 - 1 HR EXTERIOR WALL ASSEMBLY i -x& ARB 6C OARD NP TRUSS LD MM TRUSS IN V PROM 10ACZ Or WALL) (allTYPE X 6100 /16" LP PLAMNBLOGK XTMItIOR WALL GOVCRIN6: I. PIBCR GCMENT BOARD 2. TI-11 SIDING 3. WOOD PIBM PAWL 4. GI:MCNT PLASTGR (STUCCO) 5. STML SIDING 2X6 WALL STUD THICKNE55:2-1/6" (PIRW APPROX. Y CISHT: '7 PSP (PIRW PIRATEST: UL ROM, 9-12-46 C5 UL D16N UBBB 6ABLE END P I REWALL METAL L LE55 THAN V TO THE PROPERTY LINE &A FILE NO. AF 3640 (GENERIC I HOUR) ONE LAYER No' TYPE X GWB APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF MIN 2X3 STUDS, TURNED FLATWISE, 24' O.G. WITH rod CEMENT-COATED NAILS, 1-1ke" LONG, 0.OS15 SHANK, 1/4' HEADS, -1' O.C. HORIZONTAL JOINTS STAGGERED NOT LESS THAN 12' ON OPPOSITE SIDED. NO SCALE EAVES E WALL WITHIN 5'-O' OF PROPERTY LINE PER IRC 302 E TABLE R302.1 H I HOUR F21RE-RE515TIVE DETAILS STUD NOTCHING AND BORING - BEARING OR EXTERIOR WALL NOTCH 25%, BORING 40%. - 609e BORING IF DOUBLED 4 LESS OR EQUAL SUCCESSIVE STUDS. - NON -BEARING MAXIMUM NOTCH 40%, BORING 60%. - HOLES NO CLOSER THAN 5/8 INCH TO FACE OF STUD. TYPICAL EXTERIOR WALL: (2)2x6 TOP PLATES 2x6 STUDS m 16' O.G. 2x6 BOTTOM PLATE 1/2' SHT'G (APA RATED 24/0) AIR BARRIER EXTERIOR SIDING PER ELEV. R-21 INSULATION W/ CONT. VAPOR BARRIER (WARM SIDE) 1/2' GYP. BD T IGHTL INE FOUNDATION DRAIN: 4' DIA. PERF. PIPE PEA GRAVEL FILL WRAP W/ FILTER FABRIC ATTIC VENTILATION AT LEAST 4096 4 NOT MORE THAN 50% OF REQUIRED - VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY EAVE VENTING. COMPOSITION ROOF W/ 300 INTERWOVEN FELT ON 1/2' 24/0 PLYWOOD SHEATHING ALL ROOF FLASHING TO BE MIN. 26 GA GALV. STEEL. ROOF DRIP EDGES PER SEC. RS052.8B PROVIDE DRIP EDGE AT EAVES 4 GABLES W/ A MIN. 2' OVERLAP. 2x SCREENED EAVE VENT BLOCKS W/(4) 21i8' HOLES EACH - PROVIDE APPROVED INSULATION BAFFLE TO ENSURE 1' MIN. AIR SPACE. COVERED PORCH �2 600 R-36 INSULATION HIGH DENSITY 12 W1 IN 3(" MIN. 6x6 PT POST TYPE 'X' GWB SIDING OR TRIM PER PLAN POST DETAIL FOR STRUCTURES LESS THAN 5' FROM PROPERTY LINE AF50 ROOF VENTS (50 50. IN. NET FREE AREA) SOLID TIGHT FITTING TRUSS BLOCKING 2x8 FASCIA BOARD 2x STUDS PER PLAN N6' SHEATHING EXTERIOR WALL COVERING PER PLAN EAVES WITHIN 5'-0' OF PROPERTY LINE PER IRC 302 4 TABLE R302.1 ATTIC /!C A iPE MANUF TRUSSES 241O.C. SEE ROOF FRAMING PLAN FLOOR CONSTRUCTION: 1/8' T4G PLYWOOD SUB-FLR GLUED 4 NAILED TO (SEE FRAMING PLAN FOR SIZE AND SPACING) STAIR NOTES' HANDRAILS WILL BE RETURNED PER IRC R311.1 OR SHALL TERMINATE IN NEWEL POST OR SAFETY TERMINALS PER IRC R311.1$Z • STRINGERS TO BE FIRE BLOCKED AT BOTH TOP AND BOTT HANDRAIL TO BE PRESENT ON • ALL USABLE SPACE UNDER STAIRS TO BE I HOUR 4' SPHERE SHALL ONE SIDE Or- STAIR HANDGRIPSPORTION OF HANDRAILS CONSTRUCTION. NOT PASS THROUGW SHALL HAVE CIRCULAR CROSS SECTION • MAXIMUM RISE TO BE 1-3/4'. OF 11/4' MIN. 4 2' MAX EDGES SHALL HAVE A MIN. RADIUS OF t16'. • MINIMUM RUN TO BE 101. .4 G. ALL REQUIRED GUARDRAILS TO BE 36' • MINIMUM HEAD HEIGHT TO BE V-8'. MIN. IN HEIGHT. • MINIMUM STAIR WIDTH TO BE 36'. OPENINGS FOR REQUIRED GUARDS ON • PROVIDE CONTINUOUS HAND RAIL 34' TO 38' OFF THE SIDES OF STAIR TREADS SHALL NOT TREAD NOSING AND MUST EXTEND BEYOND BOTTOM ALLOW A SPHERE 4 WHO (W2mm) TO PASS Tk%OUC*L TREAD. PER R312.13 • PROVIDE GUARD RAILS AT LANDINGS, OPEN SIDED NOSINKC, 11/4' MAX WALKING SURFACE, STAIRS, RAMPS, PORCHES, OR BALCONIES • MIN. 36' HIGH W/ CLEAR SPACE PER R312JJ AND R312.12 � F HANDGRIP PORTION OF HANDRAIL SHALL BE pp co NOT LESS 1 1/4' NOR MORE THAN 2' IN CROSS SECTIONAL DIM. • WINDING TREADS 2! I / 10 HANGER PER IRC R311.1BZ "� (SLOPED SEAT) • SPIRAL STAIRS 10, MIN. ;p TREAD 6' SPHERE UNABLE TO PASS THROUGH OPENING PROVIDE MIN 1 1/2' RUN A A POINT 12' FROM WHERE TREAD IS NARROWEST BELOW STAIR INSTALL 't12' GWB • CEILING, AND WALLS PER IRC R311.1.10.1 3-2XI2 STRINGERS / (MAX SPAN UP TO T-09 / (SPANS UP TO 9'-01) ADD 1-2X6 TO BOTTOM OF STRINGERS CONT. HANDRAIL 34'-38' / W/ 16d • 12' O.C. ABOVE TREAD NOSING. / 2X4 THRUST BLOCK (SPANS UP TO 10'-01) PICKETS PER IRC ADD I-2X6 TO BOTTOM OF EACH SIDE ON OPEN SIDE INTERIOR OF Tie STRINGERS / W/ 16d 0 12, O.C. / DECK 1' PT RISERS JOISTS PER PLAN FIRE BLOCKING *0 MID -SPAN AND / IN STUD WALLS ALONG AND IN LINE �( r��;4 WITH STRINGERS IF AREA UNDER / pBL JgT STAIRS IS UNFMISI-ED P.T. 2XI2 TREADS TO STRIP 'MIN. R-441 INSULATION / -Z EXTERIOR HL 35 ANGLE SUPPORT HU21z MTL. HANGERS AT EA STRINGER 3-2XI2 PT STRINGERS (MAX SPAN UP TO T-0') (SPANS UP TO 9'-09 ADD 2X6 TO BOTTOM OF STRINGERS W/16d*12'0r- (SPANS UP TO 10'-01) ADD 2X6 TO BOTTOM OF EACH SIDE OF THE STRINGERS W/ 16d 0 12' O.C. J TYPICAL STAIR DETAIL AND NOTES FIRE BLOCKING AND DRAFTSTOPPING: PER SECTION R302.11 • R302.12 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: A. VERTICALLY AT THE CEILING 4 FLOOR LEVELS B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10'-0' 2. AT ALL INTERCONNCECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES AT STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SEC. R302.1. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. IU =O MASTER -Ito 10P 1L BATH 4i of �n COVERED PATIO ~ ENTRY w 6RE T TYPICAL EXTERIOR WALL -Ito ClO (2) 2x6 TOP E TYP. INT. WALL ROOM -� 2x6 STUDS � 16 O.G. Q N 1L (2)2x4 TOP M 1/2' SHT'G (APA RATED 24/0) _ _ z J 2x4 STUD m WATER PROOF BARRIER = d 16, O.G. EXTERIOR SIDING - 1/2' GWB EA. FLOOR CONSTRUCTION: PER ELEVATION p SIDE 3/4' T4G PLYWOOD SUB-FLR R-21 INSULATION W/ CONT. dJ 2x4 BOT. fE GLUED 4 NAILED TO VAPOR BARRIER (SEE FRAMING PLAN FOR (WARM SIDE) SIZE AND SPACING) i GRADE CRAW SPACE / L .� 6 MIL VISQUEEN VAPOR BARRIER THROUGHOUT LAP SPLICES 12' MIN. ° U I Ll:) I N6 SECT I ON 3/811 I'-oil z C H­4 CODg 00 w .4 •:• 3 A c� -E �,b w ♦♦♦ 00 ® M UN 444 H Z o yn "0 M ♦ N N 0 �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: L2-3006-3L Date: 2-20-24 MAIN FLOOR F.LEGTRIGAL INTERIOR STAIRWAY ILLUMINATION PER SEC R3031 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303b IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. UPPER FLOOR ELECTRICAL 1/4" =1'-O" ELECTRICAL KEY OVERHEAD CAN OUTLET DUPLEX OUTLET 220V OUTLET COMBO. EXT. FAN (VTOS) t LIGHT COMBO SMOKE ALARM - CARBON MONO. DET. e 110 V W/ BATTERY BACKUP CABLE T.V. JACK PHONE UNDER COUNTER LIGHTS MC Y GAS OUTLET t HOSE BIBS 4 EXT. FAN VTOS HEAT DETECTOR INTERCONNECTED e H PER 31423 (GARAGE) CHARGER V (ELECTRICVEHICLE) ONE PER DWELLING PER SEC R335 IRC SMOKE DETECTOR 110V 0° 110 VOLT PER 3143 S.D. W .:. a ♦♦♦ y � oN0 � QCAz00 1-4 ♦ N N O �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2-3006-3L Date: 2-20-24 I� L,J UPPER FLOOR FLAN GENERAL NOTES: I_0. I. ALL WORK TO BE IN CONFORMANCE WITH 2O18 ERG. 14'-0' 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES 6'-8''-1�• 6'-9*' -'_2k TO OUTSIDES, 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND 8/ 5/0 XOX _ _ _ _ _ _ _ _ MECHANICAL PENETRATIONS. - - - - - - - - - - - - - - - - 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE D5WN_ U "l` 6. SHOWERHEADS 4 KITCHEN FAUCET TO BE LIMITED TO PNTRI MAXIMUM 1.15 G.P.M. FLOW. ALL OTHER LAVATORY 9' CLGL I I FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.P11 FLOW. `n I I -I. ALL GLAZING WITHIN 604 ABOVE DRAIN INLET TO BE Q I I Q SAFETY GLASS. DININ6 ROOM d5 I I S. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN IS' OF 9' CLG. GD RED @ FLOOR TO BE SAFETY GLASS }� T10 I } 9. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN I H_ � C I I THE FOLLOWING LOCATIONS: IN EACH SLEEPING* ROOMS, It OUTSIDE EACH SEPARATE SLEEPINGs AREA IN THE +N I I ® U I I IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH It '-10' HICsHI I I I ADDITIONAL STORY OF THE DWELLING, INCLUDING - OPENINGS r- O - - - - - - - - - - - - - - 8l�x5/ XOX BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO - - T - - �'"�' H - - BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR IG L( t SHOWER ALARMS t0 BE INTERCONNECTED IN SUCH A z � "� ;q MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. ' dl c14 �4 =SMOKE ALARM -CARBON MONOXIDE COMBO. X U -pW 6 T ROOM 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 s 3} \ I \� 9' CLG. AN APPROVED CARBON MONOXIDE ALARM SHALL BE � 1~-1 tu S , INSTALLED ON EACH FLOOR 4 OUTSIDE OF EACH 01K1 w 1 KITCHEN T 0 SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE - it k 9' CLG_ I r\ - BEDROOMS. PER 2018 IRC 4 WA. STATE AMENDMENTS m 4 R40 j _ 11. (INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC W/ MICRO 3'-!f' -6. R40353. 12. ALL DUCTS 4 EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-S PER 0 MANUF. NAT. GAS WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN METAL FIREPLACE V P THE GROUND SHALL BE INSULATED TO R-10 WITH i•, INSTALL R MFR INSULATION DESIGNED TO BE USED BELOW GRADE. b a.� i - 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO r-- = SP H1C�-4 N WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE NI U 0 - OUTSIDE THE BUILDING. PER R303.52. -_ 14. rAA6 PIPING16 T 1 t,j 1 Q WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING 19 SD' 3'-9'® `['-10' H OPNG. ``� LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING UP X = MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE 6UEST SUITE VP V I 144 11 I 0 4R, PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH 1 1 1�' `4 OF THE PIPE AND THE FRAMING MEMBER AND THAT rA It EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE $ATH I I in ER S 1 FRAMING MEMBER. WHERE THE FRAMING MEMBER THAT 5' GLG I 1 PROTEG THE PIPIWx PASSES TI-IFWUC- I4 IS A BOTTOM PLATE, � CFM UP I 1 - BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD -1 50 EF. I I PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM HEAT � a I 1 r FRAMING* MEMBER AND NOT LESS THAN 4 INCHES BELOW WAITER HTR HWH THE TOP FRAMING MEMBER HWH NOTES I Z - 15. ATTIC 4 CRAWL ACCESS HATCHES OR DOORS SHALL BE VEHICLE I U WEATHERSTRIPPED AND INSULATED TO A LEVEL - PROVIDE EXPANSIONTA BARRIE I O EQUIVALENT TO THE INSULATION ON THE SURROUNDMG ® - PROVIDE SEISMIC ST PPINCs 1' MIN. LID CORE SELF GLOSNG DOOR IL - TPRV TO TERMINATE D I IL� SURFACES D,STEEL 16. WHOLE HOUSE VENTILATION 24 HR TIMER READILY OUTSIDE OR 20 IN. RATED I s ACCESSIBLE 4 WITH LABEL AFFIXED TO CONTROL THAT M - PILOT 4 CONTROLS TO BE IS' 61MIN. OFF O� J X READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING - PER ASNFRAE LOOR 9090-A- O 1 UP -4 �`' INSTRUCTIONS) - NAT GAS WATER HTR. W/ MIN.., I R al 1-1. DRYER DUCT SPECIFIED L NGTH PER SEC 1-11502A5.1. OF 0.62 1 THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE - ELECTRIC WATER H W/ MR. 6'11 3`-6" 5'-0' I i6'' ' 35 FEET(10b68mm) FROM THE CONNECTION TO THE 0,93 I TRANSITION DUCT FROM THE DRYER TO THE OUTLET 6ARAISE TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM USE 1/2' GWB ON ALL WARM AND i ►mot) ENTRY LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN STRUCTURAL WALLS. (1) LAYER 5/6' TYPE OPEN TO ACCORDANCE WITH THE TABLE M1502.4B.1. THE MAXIMUM 'X' ON CEILINGS_ WRAP ALL EXPOSED POSTS I ABOVE =" LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE AND BEAMS IN 1/2' GW5 TRANSITION DUCT. n F DUCT OPENINGS I 18. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME 4, IN GARAGE. I WALLS SHALL BE INSULATED BY COMPLETELY FILLING DUCTS THR C-A-1 CLG OR I ifSA THE CAVITY WITH A MATERIAL HAVING A THERMAL .6 WALL COMMON t0 HOUSE, I RESISTANCE OF R-3 PER INCH MINIMUM PER 2016 WSEC MIN. 26 GAGE STEEL. TABLE R402AA.1. IS, STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE _� • Os IS'_ 2/ 610 2/0x6 0 FX TO A SUPPORT AT THE TOP PLATE(DBL_ TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) HEAT DETECTOR GO RED V P INTERCONNECTED 1 PER 31423 P RCiH ll .0 8/0 x 8/0 OH. D 8'-3' R.O. 16/0 x 8/0 O.H. DOOR 16'-3' R.O. BLUE 16 AWG TRACER wFZE MEETALL WAITER SERVE LANDING AT 'EXIT' DOOR PIPING PER UPC 604.9 NOT TO BE LOWER THAN US INCHES FROM TOP OF 2'-9' 2'-9' 2-11 ' THRESHOLD. (R3113.1) 29'-3' 10'-43' FLOOR: UPPER FLOOR: TOTAL: GARACGE : 1562 50. FT. 1642 50. FT. 5004 90. FT. 640 50. PT. PORCH: Srt 50. FT. PORCH: 140 50. FT. COPYRIGHT 2012 Landmark Design Inc. ALL Rr-A-98 RESERVED MAIN FLOOR PLAN 1/4"=1'-O" INTERIOR STAIRWAY ILLUMINATION PER SFr SW-Z j IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOUf;rE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN I FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDMGv. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIG�­ITING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC RW3s IRG EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LAND]Ws OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POILER FROM THE BUILDIWx WIRINGS. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE 80TTOM LANDING OF THE STAIRWAY. �1TILITY ROOM NOTESA-lAKE UP AIR PER IRC G2439 L WHERE THE EXHAUST DUCT 15 CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G2439.1.5. 2. INSTALLATIONS EXHAUSTING: MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR. MEANS PER G243%5. E = 100 SQ INCH TRANSFER GRILL zT� W a •;� �w '` z x F•1 E 00 A 1. tR `c Fi �19 N N x 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: L2-3006-3L Date: 2-20-24 PJA GENEAL &TfRUGTUfRAL NOTES V STEM WALL ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, WITH WASHINGTON STATE AMENDMENTS. DESIGN LOADS: ROOF LIVE LOAD 25 PSF (SNOW) DEAD LOAD 15 PSF FLOOR LIVE LOAD 40 PSF (RESIDENTIAL) 60 PSF (DECKS) DEAD LOAD 10 PSF WIND BASIC WIND SPEED 110 MPH (3 SECOND GUST, ULTIMATE LOAD) RISK CATAGORY II, EXPOSURE B, Kn = 1.0 SEISMIC EQUIVALENT LATERAL FORCE PROCEDURE BEARING WALL SYSTEM (LIGHT -FRAMED WALLS) SITE CLASS: D SEISMIC DESIGN CATAGORY: D Ss = 1.5 - IBC FIGURE 161330) Sc* 1.0, 1e - 1.0, R=6.5 Cs = 0.154 INSPECTIONS: NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURF -ACES SHALL BE INSPECTED BY A SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. FOUNDATIONS: PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WITH 1,500 PSF BEARING CAPACITY (ASSUMED). BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM 1'-6" BELOW OUTSIDE FINISHED GRADE. BACKFILL WALLS WITH A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS. CONCRETE: THE SELECTION OF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, 2018 EDITION. MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENSE, WORKABLE MIX HAVING A MAXIMUM SLUMP OF 4 INCHES WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER USE MINIMUM Pc = 3,000 PSI WITH 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 52 GALLONS OF WATER PER 94 LB SACK OF CEMENT. ALL CONCRETE SHALL CONTAIN AN AIR ENTRAINING AGENT. THE AMOUNT OF ENTRAINED AIR SHALL BE 41/2% ilB% BY VOLUME. MAXIMUM SIZE OF AGGREGATE IS 11/2 ". ALL CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS UNLESS SHOWN OTHERWISE. CONCRETE PURVEYORS/SUPPLIERS DELIVERY OR BATCH TICKET TO BE ON JOB SITE FOR BUILDING INSPECTOR VERIFICATION. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE MINIMUM GRADE 60 (Fy = 60,000 PSI) DEFORMED BARS IN ACCORDANCE WITH ASTM SPECIFICATION A-615. LAP ALL SPLICES 32 BAR DIAMETERS OR 1140" MINIMUM UNLESS OTHERWISE SHOWN. PROVIDE ELBOW BARS (32 DIA.) TO LAP HORIZONTAL STEEL AT COMERS AND INTERSECTIONS IN FOOTINGS AND WALLS. REINFORCEMENT SHALL BE ACCURATELY PLACED AND ADEQUATELY SUPPORTED BY APPROVED CHAIRS, SPACERS, OR TIES AND SECURED IN PLACE DURING GROUT OR CONCRETE PLACEMENT. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: USE SLAB AND WALL BARS: INTERIOR FACES EXPOSED TO WEATHER OR EARTH FOOTING BARS PROTECTION 11/2 u 11/2 ("5 AND SMALLER) 2" (% AND LARGER) 3" TIMBER: ALL LUMBER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: BEAMS DF*2 OR BETTER POSTS DF*2 OR BETTER 2x FRAMING PM OR BETTER ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WWPA GRADING RULES FOR WESTERN LUMBER", LATEST EDITION. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA UI. RE -TREAT ALL CUT ENDS, NOTCHES, AND DRILLED HOLES IN ACCORDANCE WITH AWPA M4. MAINTAIN MINIMUM 6" CLEAR BETWEEN WOOD AND EXPOSED EARTH. MAINTAIN 8" CLEAR BETWEEN EXPOSED EARTH AND NON -TREATED WOOD AT EXTERIOR FOUNDATION WALLS. ALL NAILS SHALL BE GALVANIZED BOX OR COMMON NAILS. FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL IN ACCORDANCE WITH SECTION IBC 2304.10.5. ALL MINIMUM NAILING SHALL BE PER IBC TABLE 2304.10.1 U.N.O. MACHINE BOLTS TO BE A-301. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICC APPROVED EQUAL. ALL HANGERS TO BE FASTENED TO WOOD WITH PROPER NAILS AND ALL HOLES SHALL BE NAILED. GLUED LAMINATED UJOOD MEMBERS: GLUED LAMINATED WOOD BEAMS (GL5) TO BE IN ACCORDANCE WITH ANSI/AITC STANDARD A190.1, AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER USE STRESS GRADE COMBINATION 24F-V4 (Fb = 2,400 PSI) FOR SIMPLE SPANS AND 24F-V8 FOR CANTILEVER AND CONTINUOUS SPANS. SIMPLE SPANS SHALL BE CAMBERED ON A 3500' RADIUS U.N.O. GLUE SHALL BE CASEIN WITH MOLD INHIBITOR UNLESS OTHERWISE SPECIFIED, SEALER SHALL BE APPLIED TO ENDS OF ALL MEMBERS. BOTTOM LAMINATION TO BE FREE OF UNSOUND KNOTS LARGER THAN 1/2" DIAMETER AITC STAMP AND CERTIFICATION REQUIRED. PREFABRICATED JOISTS: JOISTS SHALL BE AS NOTED ON THE PLANS AND AS MANUFACTURED BY TRUSS JOIST WEYERHAEUSER OR APPROVED EQUIVALENT. JOISTS TO BE ERECTED IN ACCORDANCE WITH THE PLANS AND THE MANUFACTURER'S DRAWINGS AND INSTALLATION INSTRUCTIONS. CONSTRUCTION LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE ERECTION BRACING UNTIL SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKING AT CONCENTRATED LOADS FROM ABOVE AND WEB STIFFENERS PER MANUFACTURER'S DIRECTIONS. JOIST HANGERS TO BE SIZED AND PROVIDED BY THE MANUFACTURER OR SUPPLIER LAMINATED VENEER LUMBER (LVL): LAMINATED VENEER LUMBER (LVL) TO BE BY TRUSS JOIST WEYERHAEUSER (MICROLAM - Fb = 2000 PSI, E = 1,900,000 PSI). MATERIAL SHALL BE DESIGNED 4 MANUFACTURED TO THE STANDARDS SET FORTH IN NER-481 OR CCMC REPORT NO.08615-R. BEARING LENGTH SHALL NOT BE LESS THAN 11/2 ". DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER HEEL CUTS SHALL NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER BEARING WALL FRAMING: ALL DOOR AND WINDOW HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE 48 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5'-0" OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 5'-0" WIDE. STUDS SHALL BE CONTINUOUS FROM SILL PLATE AT FOUNDATON TO TOP PLATE AT ROOF OR CEILING. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE TWO (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d is 12" O.C. STAGGERED. STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAIL WITH 16d 61 8" O.C. SHEAR WALLS; ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND NOTED IN THE SHEAR WALL SCHEDULE. USE APA RATED SHEATHING (24/1(o) WITH A MINIMUM PANEL EDGE NAILING OF Sd a 6" O.C. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL BE COMMON WIRE OR GALVANIZED BOX NAILS. FASTENERS IN PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. BLOCK ALL UNSUPPORTED PANEL EDGES. DESIGNATED 3x FRAMING MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d 6 12" O.C. STAGGERED. ALL HEADERS SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END WHEN THE HEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' LSTA24 CONNECTOR U.N.O. FLOOR AND ROOF FRAMING: DIMENSIONAL FRAMING MEMBERS SHALL BE FREE OF SPLITS, CHECKS, AND SHAKES. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE LENGTH AND ALL AROUND ALL OPENINGS IN FLOORS AND ROOFS U.N.O. PROVIDE SOLID BLOCKING AT RIM JOISTS BELOW CONCENTRATED LOADS FROM ABOVE. APPLY 3/4" RATED SHEATHING (40/20) GLUED AND NAILED TO FLOOR FRAMING MEMBERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT ALL SUPPORTED EDGES AND Sd COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. APPLY 1/2" RATED SHEATHING (24/1(o) ON ROOF NAILED TO STIFFENERS OR RAFTERS WITH Sd COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT SUPPORTED EDGES AND Sd COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES. FLOOR AND ROOF TRUSSES: TRUSSES TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH ANSI/TPI 1-2014. THE TRUSS CALCULATION PACKAGE SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT PLAN AND TRUSS DESIGN DRAWINGS. EACH TRUSS SHALL BE PLANT FABRICATED AND SHALL BEAR THE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE ICC APPROVED. LOADS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED DESIGN LOADS AND IBC CHAPTER 16. MANUFACTURER SHALL PROVIDE ALL TRUSS -TO -TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AND MAINTAIN DRAWINGS ON SITE FOR INSPECTION. CONTRACTOR TO VERIFY ALL TRUSS LENGTHS PRIOR TO FABRICATION AND INSTALLATION. TRUSSES SHALL BE BRACED TO PREVENT ROTATION AND PROVIDE LATERAL STABILITY IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND INDIVIDUAL TRUSS DRAWINGS. NO TRUSS SHALL BE ALTERED WITHOUT PRIOR WRITTEN CONSENT OF THE TRUSS DESIGNER AND ENGINEER OF RECORD. GENERAL CONSTRUCTION NOTES: ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, AND SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT THE JOB SITE INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT OR ENGINEER SHEAR WALL SCNEDULE MARK MINIMUM SHEATHING (1) SHEATHING NAILING (1) ANCHOR BOLTS (3) REMARKS (4, 5) I/2" CDX 8d 6 6" O.C. 5/8" a 60" O.C. Qa II = 230 PLF OR OSB 1/2" CDX 8d im 4" O.C. 5/8" 6 32" O.G. Qall = 350 PLF OR OSB I/2" COX ad a 3" O.C. 5/8" a 1(0" O.C. QaII = 450 PLF C OR OSB USE 3x STUDS AT ABUTTING PANEL EDGES 4 STAGGER NAILS R SEE DETAIL 12 / 52.0 FOR CONSTRUCTION NOTES 1) ALL WALLS DESIGNATED" D11 ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH RATED SHEATHING (24/0) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER SCHEDULE. NAILING AT Tl-II PANELS SHALL BE THROUGH EACH EDGE OF EACH PANEL. NAILING AT INTERMEDIATE FRAMING TO BE AT 12" O.C. NAILING NOT CALLED OUT SHALL BE PER IBC TABLE 2304.10.1. NAILING IN PRESERVATIVE TREATED LUMBER SHALL BE STAINLESS STEEL OR OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL PER ASTM A153. 2) HOLDOWNS AND OTHER FRAMING HARDWARE BY SIMPSON STRONG TIE OR ICC APPROVED EQUAL TO BE USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINIMUM. 3) USE MINIMUM OF TWO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINIMUM OF 1" INTO CONCRETE. WASHERS TO BE 3" x 3" x 1/4" PER IBC SECTION 230832 AND OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL IN ACCORDANCE WITH ASTM A153. 4) ALLOWABLE LOADS ARE PERMITTED TO BE INCREASED 40% FOR WIND DESIGN IN ACCORDANCE WITH AF4PA SDPWS TABLE 43A. 5) DESIGNATED 3x STUDS MAY BE (2) 2x MEMBERS FACE -NAILED WITH 1(od 6 12" O.C. STAGGERED. F_ I I I I I I I I I I I I I I I I I I I L L; (TYP. 2 PLACES) LSTA36 - MR 4 SILL TO 3x BLOCKWs, MID. 2 PLACES) LSTA30 - BEAM t0 TOP PLATE r21/2 G x 105 CsLB 51/z x 15 GLB — — — m 51/2 A5 GL5 _ LSTA24 - BEAM TO TOP PLATE NTS20 - BEAM TO TOP PLATE B LSTA30 - BEAM TO TOP PLATE. (TYP OF 2) MAIN FLOOR A = 1,362 SQ FT �I A - 640 SQ FT m _ ".t GL5 _ 31/2 x 16B GLIB � ry1IF t R iL —13/ x 18 4x12 �� �r4x12 MID. OF LSTA30 - TOP PLATE TO 3x BLOCKIws a a 97__ a ° 2'-0" a ADD �4 -/ BAR FOR Lz� STEPS EXCEEDING 2'. 4 S" MAX 1 MAX CONTINUOUS FTG. MINIMUM REINFORCEMENT STEPPED FOOTING DETAIL s10 SCALE: 3j4" • I'-0" MSTC40 HOLDOWN. ALIGN WITH EMBEDDED STND TYPE 14OLDOUN BELOW. SHEATHING 4 NAILING PER PLAN. SPLICE TO OCCUR ON COMMMON MEMBER OR BLOCKING SHEATHING 4 NAILING PER PLAN. MATCH WALL ABOVE UNA. FINISH GRADE Ibd 6 16" O.C. SOLE PLATE NAILING. 3/4" SU5FLOOR /,/-(3) ad JOIST -TO -TOP PLATE U.N.O. MAINTAIN 4fMIR 11/2" END DISTANCE. 2 x 6 STUD ® 16" O.C. USE -D5L STUD ® ENDS OF SHEAR WALLS 4 HOLDOWNS. 2x PT SILL w/ 5/&" OANCHOR MAX - BOLT 4 3" x 3" x Ii4" WASHER AT 5'-0" O.C. UNA. (ALT. MASA 5 48" OL) STND TYPE HOLDOWN PER PLAN. -"4 BAR * 10" O.C. - HORIZ (36° #4LBAR a 16" Oz. - VERt. FINISH GRADE 04 BAR CONTINUOUS p (TYP OF 2) D p � p D � K_2_'� CRIPPLE WALL WITIH BACKFILL FOUNDATION 2LO/ : 34" • 11-01 GOPYRIeHT 2024, SEeA ENe1NEER5 H z l� N O N ly O La -1wLu V -4 N cn Ll N W 0� �o A I m 0 co � o co U 0 a b a cQ 0 cq w cq cq ON JOB 14-011 '/2" RATED SHEATHING Sd Q 6" O.C. SHEATHING 4 NAILING PER NOTE: NOTE: (4" O.C. a SIM.) SEE ARCH FOR FLASHING '/2" RATED SHEATHING w/ — PLAN OR SCHEDULE. REQUIREMENTS. TRUSS t0 DEVELOP = � Sd 4" O.C. TO FRAMING CAPACITY OF CONNECTOR Q w STAGGERED SHEATHING 8d a 4" O.C. N PER PLAN. EXTEND OVER HI FRAMING ANCHOR TRUSS PER PLAN �' N 2x VENTED BLOCKING. EACH TRUSS. USE H10A-2 ROOF SHEATHING c� Q ad Is 6" O.C. AT DBL TRUSS. GABLE END TRUSS. � 1 PER PLAN 2x BLOCKING D5L 2x TOP PLATE. LL w w (BEAM AT SIM.) q n U � A35 a 48" O.C.— tRUSS PER PLAN DBL 2x TOP PLATE. LAP (USE 24" O.C. At SIM.) 2x STUD CONNECTOR SCRAP 2x VENTED BLOCKING. SPLICE 4'-0" MIN. 4 NAIL w/ 2x BRACE PER TRUSS SUPPLIER END NAIL TO TRUSS DBL 2x TOP PLATE. LAP SPLICE 16d 6 6" O.C. STAGGERED. OR 6 48" O.C. SECURE w/ PER PLAN. EACH END w/ (2) 8d. \_4'-O" MIN. 4 NAIL w/ 16d 6 4" O.C. A34 EACH END. TRUSS OR RAFTER NOTE: STAGGERED. ADD L5TA24 TO PER PLAN INSTALL CONNECTOR PRIOR WALL SHEATHING AND NAILING SPLICE PER PLAN SHEATHING 4 NAILING .. �1 PER PLAN OR SCHEDULE. PER PLAN OR SHEAR \r7 I 2x FRAMING PER PLAN. 2x STUD (NOT SIM) t0 PLACING COMMON TRUSSES m SPLICE TO OCCUR ON COMMON 2x FRAMING PER PLAN. WALL SCHEDULE. (HEADER 6 SIM.) 2x NAILER OR TRUSS � o MEMBER OR BLOCKING w/ 16d Is 8" O.G. w a an 1 TYPICAL ROOF FRAMING CONNECTION 2 ROOF FRAMING GA5LE END 3 ROOF FRAMING 5HEAR LUALL 4 DRAG 5TRUT CONNECTION .a S2 0 SCALE: V = I'-0" S2 0 SCALE: V = I'-0" 52.0 SCALE: 1" = I'-0" S2 0 SCALE: P = V-0" 4� b U q 16d 16" O.C. SOLE DBL 2x TOP PLATE o PLATE NAILING. FLOOR TRUSS PER PLAN (3)16d TO TRUSS WEB (TYP.) SUBFLOOR PER PLAN ��2" RATED SHEATHING 16d 4" O.C. SOLE � A SUBFLOOR PER PLAN i NAILING PER PLAN. PLATE NAILING. HDR PER PLAN. -_ _-_ _ _ _ _ _ _ __Y___,___________________________ _T 0 0 i2 SHEATHING w/ Sd Sd a 4 O.C. - - --- - --- - --- bt 2x CONTINUOUS RIBBON (3) 8d JOIST -TO -TOP 6" O.G. EDGE NAILING. 2x FRAMING w/ (3) 2x CONTINUOUS ! ! PLATE U.N.O. MAINTAIN (NOT 's MANF PANEL) 16d TO TRUSS WEB RIBBON SUBFLOOR PER PLAN -----------i MIN. 1 12 END DISTANCE. r', MSTC HOEDOWN 3x BLOCKING. EXTEND STRAP PER PLAN b (2) BAYS (24" MINIMUM) j OR TO CORNERcQ SHEATHING 4 NAILING PER PLAN. �' ,� 1 (TYP) SPLICE TO OCCUR ON COMMON --- ------ ------- ------- ------- ------ -_ ! TRIMMER STUDS) MEMBER OR BLOCKING W CQ MSTC HOEDOWN � � ��2" SHEATHING INFILL BLOCKING w/ 2x FRAMING PER PLAN. PER PLAN j 1 FLOOR TRUSS Sd 's 6" O.C. EDGE NAILING OR (BEAM AT SIM) 1 MANUFACTURED BLOCKING PANEL. KING 5TUD—\ PER PLAN FLOOR TRUSS PER PLAN 2x FRAMING PER PLAN. 16d 6 4" O.C. (BEAM SIM.) 2x DBL TOP PLATE. LAP SPLICE 4'-0" MIN. 4 NAIL w/ 16d 4" SHEATHING 4 NAILING PER j O.C. STAGGERED. PLAN OR SCHEDULE. BEAM PER PLAN. ! j 112" RATED SHEATHING 4 j NAILING PER SCHEDULE. LSTA STRAP PER 5 TIFICAL FLOOR FRAMING CONNECTION FLOOR FRAMING Q INTERIOR 5HEAR WALL 5HEAR WALL FRAMING AT SEAM PLAN (TYP). S2 0 SCALE: V _ 1'-0" S2 0 SCALE: V _ 1'-0" S2 m SCALE: P 2 1'-0" 1 2x SILL PLATE 1 j SHEATHING 4 NAILING PER PLAN. — SPLICE TO OCCUR ON COMMMON ! I MEMBER OR BLOCKING 16d 4" O.C. SOLE SHEATHING 4 NAILING PER PLAN. 16d 8" O.C. SOLE SPLICE TO OCCUR ON COMMON PLATE NAILING Sd 9 4" O.C. PLATE NAILING. 3x BLOCKING 16d 6 16" O.C. SOLE MEMBER OR BLOCKING i/(TYP) PLATE NAILING. SUBFLOOR PER PLAN 2" SHEATHING 2x BLOCKING AS REQ'D ado 6" O.C. UNO 8d is 4"L O.C. NOTE: SUBFLOOR PER PLAN SSA 5HEAR WALL FORCE TRAN5FER PETAL 2x BLOCKING w/ 16d 6 41 ISEE ARCH FOR O.C. ALE FLASHING REQ'TS SUBFLOOR PER PLAN TRUSS PER PLAN SHEATHING 4 NAILING ��2" SHEATHING 2x BLOCKING w/ 16d 8" O.C. PER PLAN OR MSTC HOEDOWN LSTA24 STRAP , SCHEDULE PER PLAN (FAR SIDE) I6„ NOTE: FLOOR TRUSS 2x TOP PLATE MINIMUM NAIL SHEATHING TO HDR C� FLOOR TRUSS SEE ARCH FOR FLASHING PER PLAN PER PLAN REQUIREMENTS. HDR PER PLAN. EXTEND w/ Sd 3" O.C. EACH WAY. MSTC HOEDOWN HANGER BY TRUSS SUPPLIER TRUSS OR RAFTER OVER PANES TO KING StUO. + + } ' + . + wry' STRAP PER PLAN FLOOR TRUSS PER PLAN l6)16d KING STUD TO emu, " " ' HEADER BEAM /END TRUSS BEAM PER PLAN LUS HANGER BY HANGER BY TRUSS SUPPLIER PER PLAN LU524 HANGER BY TRUSS SUPPLIER -_Ij�I TRUSS SUPPLIER TT '== T II BEAM PER PLAN 1 'i 2x KING STUD w/ 2x 1+' III g 5HEAR WALL FRAMING AT FLOP SEAM 10 FLOOR FRAMING CONNECTION � FLU5H SEAM 11 FLOOR FRAMING CONNECTION 6 5EAM FASTEN TOP PLATE TO �� CRIPPLE STUD HEADER w/ (2) ROWS �+ S2 0 SCALE: P - 1'-0" S2 0 SCALE: P 2 1'-0" 52.0 SCALE: P = V-0" 1� '1 1' 16d At 3 O.C. + : 4x BLOCKING 6 MIDDLE 'I+j 24" IF REQUIRED./ 10'-0" MAX. ,.---- -----� 16d 6 16" O.C. SOLE (8'-0" a SIM) — — - 2x BLOCKING w/ (3) Sd 2x STUD PER PLAN. USE MINIMUMOlePLATE NAILING. 'I Sd 6 O.C. TOE -NAIL TO 4x BEAM 4 (2) 2x STUD Q ENDS OF SHEAR 2x STUD PER PLAN. USE DBL ''J '/2" RATED SHEATHING (2�4/0 EXP 1). (2) Sd t0 JOISTS. WALLS 4 HOLDOWNS. SEE SHEAR 3/4SHEATHING STUD At END OF SHEAR WALLS + .I NAIL w/ (2) ROWS Sd s 3 O.C. At SUBFLOOR PER PLAN WALL SCHEDULE FOR 3x STUDS. ANCHOR BOLT w/ 3"x3"x�ia" 4 HOLDOWNS. SEE SHEAR WALL (2) 2x CRIPPLE +1+I + PANEL EDGES. � JOIST PER PLAN WASHER SEE SCHEDULE FOR SCHEDULE FOR 3x STUDS. STUDS. + +I+j SHEATHING 4 NAILING PER SHEATHING 4 NAILING PER 2x4 w/ (8) 16d AT PLAN. SPLICE TO OCCUR SIZE 4 SPACING.USE a AT PLAN OR SCHEDULE �� (2) 2x PLATE. (NAIL BEAM PLICE. ON COMMON MEMBER 60 O.C. U.N.O. '. SHT'G TO EA PLATE) 2x4 GUSSET EA 2x Pt SILL 4" SLAB ON GRADE OVER +.. SIDE wl l8) lbd (NOT A METAL CAP) OR BLOCKING. MIN. 6 MIL VAPOR BARRIER TOP OF STEM WAEE ++=—'a '+ _ (ALT. METAL CAP) *4 AR - HORIZ. 1�:6" MIN. (NOT 0 5D.G.) `! FINISH GRADE OR a � � ELEV. VARIES J + i 64 � � �'��' SLAB ON GRADE 4x4 Pt POST FINISH GRADE 12 MAX. i ' STHp HOEDOWN PER PLAN. 2x Pt SILL �- 14x6 AT SPLICE) (S.O.G. SIM.) i STN HO OWN - ' 2x Pt SILL w/ ANCHOR BOLL StHp14 HOEDOWN UNO. l2) �i "� ANCHOR BOLT w/ MIN. :4 � BAR � 24" O.C. - VERT. D LD a 4 3" x 3" x 1/4 WASHER PER s MAB ANCHOR 18„ DER PLAN a PLAN OR SCHEDULE. USE 7" EMBEDMENT 4 3" x 3" x '44" (ALT. A34 ANCHOR MIN. I'-6" MIN 1-6 a 5i8"� � 60" O.C. MIN. GALVANIZED fE WASHER � TWO SIDES) 12" 4'-0" MAX "4 BAR CONTINUOUS MIN. # " - FOUNDATION PER PLAN. MIN. > g�� _ 4 MBAR 24 O.C. VERTICAL MIN. 8 THICK STEM WALL w/ FTG PER PLAN D o 0 O O #4 BAR HORIZ. TOP 4 BOTTOM. #4 A t . o BAR CON 12 PORT�4L FRAME PANEL FINISH GRADE D � 8" (TYP.) S2 0 SCALE: NONE 5 I'-4" _ o 13 FLOOR FRAMING AT CRALUL 5PACE 14 FOUNDATION AT CRAWL 5PAGE 15 FOUNDATION AT 5LA5 ON GRADE s o SCALE: P = V-0° s2 0 SCALE: P = V-0° S2 0 SCALE: P = V-0" GOP'f'RIGHT 2024, 5EG,4 ENGINEER5 JOB 14-011