E_230112_Long Shot IR_Permit Set
0 O w N 00 O z I LIGHTING FIXTURE SCHEDULE ELECTRICAL SYMBOLS LEGEND TYPE MANUFACTURER LAMPS WATTS MOUNTING A DETAIL/SECTION IDENTIFICATION: A = DETAIL/SECTION LETTER, B = SHEET NUMBER B WHERE DETAIL/SECTION IS DRAWN. Al AXIS LIGHTING LED 30 PENDANT TB3DLED-1000-80-35-50-3'-AP- A EQUIPMENT CONNECTION CALLOUT. A,B EQUAL EQUIPMENT IDENTIFICATION ON UNV-DP-1-XX OR EQUAL B MECHANICAL EQUIPMENT CONNECTION SCHEDULES. VERIFY EXACT EQUIPMENT REQUIREMENTS ON SHOP DRAWING EQUIPMENT SUBMITTALS PRIOR TO ROUGH -IN. A1X SAME AS TYPE Al WITH DO NO ROUGH -IN FOR EQUIPMENT PRIOR TO REVIEW OF SUBMITTALS. REPORT ANY EMERGENCY BATTERY PACK DIFFERENCES IN REQUIREMENTS TO ENGINEER IN WRITING. A2 AXIS LIGHTING LED 28 RECESSED CONDUIT CONCEALED. HASH MARKS INDICATE NUMBER OF #12 CONDUCTORS IN BMRLED-750-80-35-FL-4'-W- CODE SIZE CONDUIT. NO HASH MARKS INDICATES 2412 CONDUCTORS PLUS GROUND UNV-DP-1-DF OR EQUAL IN 3/4" CONDUIT, LONG HASH MARKS INDICATES NEUTRAL CONDUCTOR. */ INDICATES GROUND CONDUCTOR. A2X SAME AS TYPE A2 WITH EMERGENCY BATTERY PACK /Zj` FLEXIBLE RACEWAY, PROVIDE GROUND CONDUCTORS PER NEC. A3 AXIS LIGHTING LED 39 RECESSED A-1,3 ADJACENT TO ARROW INDICATES HOMERUN OF CONDUCTORS IN CONDUIT FOR BMRLED-1000-80-35-FL-4'-W- CIRCUITS 1 AND 3 TO PANEL "A". UNV-DP-1-DF OR EQUAL ® EXIT LIGHT WITH BATTERY, UNIVERSAL MOUNTING. A3X SAME AS TYPE A3 WITH EMERGENCY BATTERY PACK EMERGENCY FLOODLIGHT WITH BATTERY. A4 AXIS LIGHTING LED 21 RECESSED BMRLED-750-80-35-FL-3'-W- 0 LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED ON CEILING. UNV-DP-1-DF OR EQUAL LIGHT FIXTURE, WITH EMERGENCY BATTERY PACK. A5 METALUX LED 41 PENDANT/ 4SNLED-LD5-47SL-LW-UNIV- CHAIN HUNG LIGHT FIXTURE, WALL MOUNTED. L835-CD-1 OR EQUAL 0 DOWNLIGHT FIXTURE. A6 METALUX LED 31 SURFACE/ 4SNLED-LD5-37SL-LW-UNIV- CHAIN HUNG ❑-i WALL MOUNT LIGHT FIXTURE. L835-CD-1 OR EQUAL O JUNCTION BOX. A7 BIRCHWOOD LIGHTING LED 12 WALL NOL-LED-225-HLO-35-2-MW-FW- Al LIGHT FIXTURE TYPE. Al = SPECIFIC LIGHTING FIXTURE REFERENCED ON LIGHTING 120-Dl-SM OR EQUAL FIXTURE SCHEDULE. A8 AXIS LIGHTING LED 38 WALL POWER PANEL TB3WDLED-1000-80-35-NW- 4-AP-UNV-DP-1 OR EQUAL DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED AT 18 INCHES AFF. G = GROUND FAULT INTERRUPTING, T = TAMPERPROOF, C = CONTROLLED, 1/2 OF RECEPTACLE A8X SAME AS TYPE A8 WITH CONTROLLED. EMERGENCY BATTERY PACK r� DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED HORIZONTALLY 2" ABOVE B1 HALO LED 15 RECESSED COUNTERTOP BACKSPLASH TO THE BOTTOM OF THE RECEPTACLE COVERPLATE. HC6-15-D010-H M6-0525-835- 61-MD-C OR EQUAL FOURPLEX RECEPTACLE 20A, 125 VOLT, WALL MOUNTED AT 18 INCHES AFF. B1X SAME AS TYPE B1 WITH SPECIAL RECEPTACLE. AMPERAGE AND VOLTAGE AS SHOWN. EMERGENCY BATTERY PACK B2 HALO LED 10 RECESSED ® EQUIPMENT CONNECTION. PROVIDE PER NEC AND MANUFACTURERS REQUIREMENTS HC4-10-D010-HM4-0525-835- AND/OR RECOMMENDATIONS. 41-MD-C OR EQUAL FB I FLOOR BOX. PROVIDE WITH 125V, 20A, FOURPLEX RECEPTACLE AND SPACE FOR E1 AXIS LIGHTING LED 22 RECESSED 4-PORT DATA OUTLET. W B R L E D-500-80-40-S-4'-B L K- UNV-DP-1-DF OR EQUAL SECURITY CAMERA E1X SAME AS TYPE E1 WITH WAP WIRELESS ACCESS POINT EMERGENCY BATTERY PACK E2 PERFORMANCE IN LIGHTING LED 27 WALL S H2-27-BK-4K-120-0-10V- OCC-2 OR EQUAL E2X SAME AS TYPE E2 WITH EMERGENCY BATTERY PACK E3 FC OUTDOOR LIGHTING LED 48 WALL FCC600-14-WM-UNV-940-40L- BKE-40-LD OR EQUAL X1 SURE-LITES INCLUDED 3 UNIVERSAL CX71 OR EQUAL X2 SAME AS X1 INCLUDED 3 UNIVERSAL WITH DUAL FACE Sim WIRELESS LIGHT SWITCH, SINGLE POLE, SUBSCRIPTS; 3 = THREE WAY, 4 = FOUR WAY, D = DIMMER CONTROL, a, b, c, ETC = NUMBER OF SWITCHES AT THE LOCATION AND SPECIFIC FIXTURES CONTROLLED. MOUNT AT 42 INCHES AFF. ST DIGITAL 0-12 HOUR TIMER SWITCH. WATTSTOPPER TS-400 OR EQUAL Sy AUTOMATIC/MANUAL OCCUPANCY SENSOR AND SINGLE POLE TOGGLE SWITCH. WATT STOPPER DW-100 OR EQUAL. SWITCH SHALL BE PROGRAMMED FOR MANUAL ON, AUTOMATIC OFF. OS WIRELESS AUTOMATIC OCCUPANCY SENSOR DEVICE. PS WIRELESS DAYLIGHT PHOTOSENSOR I/O WIRELESS INPUT/OUTPUT MODULE. EIJ DISCONNECT SWITCH EP FUSED DISCONNECT SWITCH WITH FUSES. SM MOTOR RATED TOGGLE SWITCH WITH OVERLOAD HEATER(S), SIZE PER NEC AND MANUFACTURERS REQUIREMENTS. 0 FLUSH MOUNTED DUAL TELEPHONE/DATA OUTLET, MOUNT AT 18" AFF. PROVIDE 4" SQUARE BOX WITH 1" CONDUIT AND PULL STRING TO ACCESSIBLE CEILING SPACE. GROUND PER NEC. 4 MANUAL FIRE ALARM PULL STATION. WALL MOUNT AT 42 INCHES AFF. Dxx EFIRE ALARM HORN/ADA STROBE. WALL MOUNT AT 80 INCHES AFF. 'T' SUBSCRIPT INDICATES CANDELA LEVEL. ED FIRE ALARM MINI ADA STROBE, WALL MOUNT AT 80 INCHES AFF. SUBSCRIPT INDICATES CANDELA LEVEL. OS SMOKE DETECTOR OH HEAT DETECTOR FS WATER SPRINKLER SYSTEM FLOW SWITCH. TS WATER SPRINKLER SYSTEM TAMPER SWITCH. xxx AVAILABLE FAULT CURRENT T TRANSIENT VOLTAGE SURGE SUPPRESSION. TPS3-X-1 1-1 5-D2, SIEMENS OR v S EQUAL. "X" = VOLTAGE/ PHASE (VARIES), SEE POWER RISER DIAGRAM S AND/OR PANEL SCHEDULES FOR VOLTAGE AND PHASE REQUIREMENTS. (E) EXISTING WP WEATHERPROOF ELECTRICAL NOTE FLAG T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com M2/23 w Z Q 0 0 z j 0 OLU (D zCD O 0 3� CD - 1 J Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 ELECTRICAL LEGEND/ LIGHT FIXTURE SCHEDULE E-00 I A CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. 0 v 0 O w N 00 O N N O� N 00 O aD I FIRST CHOICE SELF STORAGE - ----------------------- = PUGET SOUND ENERGY VAULT - PAD MOUNTEP_TRANSFORMER ON TOPD VAULT PER PSE STANDARDS. TO BE LOCATED IN LANDSCAPE AREA. ()'! 9 6 F 19 '11-' A-35,3� 2P 1 A-36,3 3i 2 P 1 A-40 ULLLLLL llll WA 507 (E YELM AVE) N ELECTRICAL SITE PLAN SCALE: 1 "=50'-0" I ' I I I I I I I I ' I I ' I I I , I I I I I' I I I I I I I I I I I , I � I � I I I I I I I I , I I I I I ' I I I I GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. ALL CONDUIT IS INTENDED TO BE CONCEALED. CONTRACTOR SHALL PROVIDE TO ARCHITECT/OWNER SHOP DRAWINGS INDICATING ROUTING OF ANY INTENDED EXPOSED CONDUIT PRIOR TO ROUGH -IN FOR ARCHITECT/OWNERS APPROVAL. CONTRACTOR SHALL NOT START ROUGH -IN FOR CONDUIT UNTIL WRITTEN APPROVAL IS RECEIVED. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 4. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-(800)-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. THE CONTRACTOR WILL ALSO BE RESPONSIBLE FOR MAINTAINING ALL LOCATE MARKS ONCE THE UTILITIES HAVE BEEN LOCATED. 5. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. 6. CONTRACTOR SHALL PROVIDE TRENCHED 1"C-FIRE ALARM CONDUCTORS AND CONNECT THE POST INDICATOR VALVE TO THE FIRE ALARM SYSTEM FOR MONITORING. SEE CIVIL AND MECHANICAL DRAWINGS FOR LOCATIONS. ELECTRICAL NOTES: PROVIDE DUAL HEAD, LEVEL 2,40 AMP PER HEAD, EV CHARGER, POST MOUNTED. LEVITON OR EQUAL. PROVIDE DUAL HEAD, LEVEL 2,40 AMP, EV CHARGER, POST MOUNTED. LEVITON OR EQUAL. PROVIDE HANDHOLE WITHIN LANDSCAPE AREA FOR ROUTING OF FUTURE EV CHARGING INFRASTRUCTURE. PROVIDE (2)1" CONDUIT ONLY WITH PULLSTRING FROM HANDHOLE TO PANEL 2P1A. CROSS ENGINEERS, INC 19 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com 1/12/23 w Z Q 0 0 z j F— z 0 � O = c� Q v ' J W V ZL0 w cD O Z O 0 Q O o Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 ELECTRICAL SITE PLAN E-1 00 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. (D O n z O 0 Ln 0 O N W N co O N N O� N 00 O z a� LL_ E N O N N 0 QD O GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. CONTRACTOR SHALL INCLUDE IN HIS BID LIGHTING CONTROL COMMISSIONING COSTS. CONTRACTOR SHALL PROVIDE THE OWNER A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS INDICATING ALL LIGHTING CONTROLS HAVE BEEN TESTED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS AND THE WASHINGTON STATE NONRESIDENTIAL ENERGY CODE, SECTION C408. CONTRACTOR SHALL PROVIDE A SPREAD SHEET INDICATING ROOM NUMBER, TYPE OF CONTROL (OCCUPANCY SENSOR, LOW VOLTAGE, ETC.), VERIFICATION OF PROPER WORKING ORDER, AND ADJUSTMENTS MADE. 3. CONTRACTOR SHALL CONCEAL CONDUIT WHEREVER POSSIBLE. CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND APPROVAL, ALL ROUTINGS OF ANY EXPOSED CONDUIT PRIOR TO ROUGH -IN. NO EXPOSED CONDUIT SHALL BE INSTALLED UNTIL APPROVAL IS PROVIDED IN WRITING FROM THE ARCHITECT. ALL EXPOSED CONDUIT SHALL BE ROUTED IN A NEAT AND WORKMANSHIP LIKE MANNER. 4. CONTRACTOR SHALL PROVIDE A HOT-WIRE OF THE SAME CIRCUIT FOR ALL LIGHT FIXTURES WITH BATTERY PACKS, SO THAT THE BATTERY PACK IS BEING CHARGED AT ALL TIMES. 5. CONTRACTOR SHALL SEE ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 6. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. 1 2 3 4 5 6 I I I I I n l 4 7 , nnI nn n rn Tvnln n l Tvnr rn Al 4 -7 1 T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com me 1 / 12/23 w Z Q j F- z 0 Q O c� v ' J W ZL0 W O Z 3 OCD 0 Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 OVERALL FLOOR 1 LIGHTING PLAN 1 2 3 4 5 6 E-200 OERALLFLOOR 1 LIGHTING PLAN CROSS ENGINEERS, INC All material herein constitutes the original and unpublished work of the architect and SCALE: 1 /16°-1 '-0° N 923 MILK Jr. Way Phone: (253) 759-0118 may not be used, duplicated, or disclosed Tacoma, WA 98405 Job Number: 22-082 without the written consent of the info@crossengineers.com architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. t1 z O cf� N N O� N 00 O z a� LL_ E N O N N O QD O 1 2 3 4 1 1 P9 T!1 1 1 /' 1 1 T e% I PARTIAL FLOOR 1 LIGHTING PLAN SCALE: 1 /811=V-0" N GENERAL NOTES: ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. CONTRACTOR SHALL INCLUDE IN HIS BID LIGHTING CONTROL COMMISSIONING COSTS. CONTRACTOR SHALL PROVIDE THE OWNER A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS INDICATING ALL LIGHTING CONTROLS HAVE BEEN TESTED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS AND THE WASHINGTON STATE NONRESIDENTIAL ENERGY CODE, SECTION C408. CONTRACTOR SHALL PROVIDE A SPREAD SHEET INDICATING ROOM NUMBER, TYPE OF CONTROL (OCCUPANCY SENSOR, LOW VOLTAGE, ETC.), VERIFICATION OF PROPER WORKING ORDER, AND ADJUSTMENTS MADE. 3. CONTRACTOR SHALL CONCEAL CONDUIT WHEREVER POSSIBLE. CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND APPROVAL, ALL ROUTINGS OF ANY EXPOSED CONDUIT PRIOR TO ROUGH -IN. NO EXPOSED CONDUIT SHALL BE INSTALLED UNTIL APPROVAL IS PROVIDED IN WRITING FROM THE ARCHITECT. ALL EXPOSED CONDUIT SHALL BE ROUTED IN A NEAT AND WORKMANSHIP LIKE MANNER. T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com me 1 / 12/23 4. CONTRACTOR SHALL PROVIDE A HOT-WIRE OF THE SAME CIRCUIT FOR ALL LIGHT FIXTURES WITH BATTERY PACKS, SO THAT THE BATTERY PACK IS BEING w CHARGED AT ALL TIMES. 5. CONTRACTOR SHALL SEE ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 6. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. ELECTRICAL NOTES: 0 100 METER RANGE LIGHTING CONTROL SWITCH. E�> 25 METER RANGE LIGHTING CONTROL SWITCH. 0 j F— z 0 Q O c� v ' J W V ZL0 W cD O Z 3 OCD 0 Project No: 2212 100% CONSTRUCTION JANUARY 12, 2023 0 PARTIAL N FLOOR 1 w W LIGHTING PLAN CO W z_ J 2 H QE-201 CROSS ENGINEERS, INC 923 MLK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. t1 z O O Ln N O N W N 00 O N N O� N 00 O z a� LL_ E N O N N 0 QD O (�) ----------------- E3 FLOOR 2 LIGHTING PLAN SCALE: 1 /8"=1'-0" 3 i +20'-0" AFG, TYPICAL TYPE E3 N TO LIGHTS, DOWN TO LIGHTS, SHEET E-201 GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. CONTRACTOR SHALL INCLUDE IN HIS BID LIGHTING CONTROL COMMISSIONING COSTS. CONTRACTOR SHALL PROVIDE THE OWNER A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS INDICATING ALL LIGHTING CONTROLS HAVE BEEN TESTED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS AND THE WASHINGTON STATE NONRESIDENTIAL ENERGY CODE, SECTION C408. CONTRACTOR SHALL PROVIDE A SPREAD SHEET INDICATING ROOM NUMBER, TYPE OF CONTROL (OCCUPANCY SENSOR, LOW VOLTAGE, ETC.), VERIFICATION OF PROPER WORKING ORDER, AND ADJUSTMENTS MADE. 3. CONTRACTOR SHALL CONCEAL CONDUIT WHEREVER POSSIBLE. CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND APPROVAL, ALL ROUTINGS OF ANY EXPOSED CONDUIT PRIOR TO ROUGH -IN. NO EXPOSED CONDUIT SHALL BE INSTALLED UNTIL APPROVAL IS PROVIDED IN WRITING FROM THE ARCHITECT. ALL EXPOSED CONDUIT SHALL BE ROUTED IN A NEAT AND WORKMANSHIP LIKE MANNER. 4. CONTRACTOR SHALL PROVIDE A HOT-WIRE OF THE SAME CIRCUIT FOR ALL LIGHT FIXTURES WITH BATTERY PACKS, SO THAT THE BATTERY PACK IS BEING CHARGED AT ALL TIMES. 5. CONTRACTOR SHALL SEE ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 6. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com me 1 / 12/23 w Z Q O O 0 z j F— Z 0 Q O c� v ' J W V ZL0 W cD O Z 3 OCD 0 Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 FLOOR 2 LIGHTING PLAN E-202 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. t1 z 0 0 cn 0 O w N co O N N N 00 O z a� E N O N N 0 Q� O GENERAL NOTES: ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. ALL CONDUIT IS INTENDED TO BE CONCEALED. CONTRACTOR SHALL PROVIDE TO ARCHITECT/OWNER SHOP DRAWINGS INDICATING ROUTING OF ANY INTENDED EXPOSED CONDUIT PRIOR TO ROUGH -IN FOR ARCHITECT/OWNERS APPROVAL. CONTRACTOR SHALL NOT START ROUGH -IN FOR CONDUIT UNTIL WRITTEN APPROVAL IS RECEIVED. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 4. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com me 1 / 12/23 w Z Q - O O 0 z j F— z 0 O c� I J W V Zr_1 W cD 0 Z 3 OCD 0 Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 OVERALL FLOOR 1 POWER PLAN 1 2 3 4 5 6 E-300 OVRALLFLOOR 1 POWER PLAN CROSS ENGINEERS, INC All material herein constitutes the original and unpublished work of the architect and SCALE: 1 /16"=1 '-O" N 923 MILK Jr. Way Phone: (253) 759-0118 may not be used, duplicated, or disclosed Tacoma, WA 98405 Job Number: 22-082 without the written consent of the info@crossengineers.com architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. a1 z O O CD w N 00 O N N O� N 00 O z a� LL_ E N O N N O Q� O (DA-7- 1-1 - - 07 EI 07 s. r. 07 a 2 ❑ I ❑ ❑ ❑ ❑� 1000AMP, NEMA 3R, UTILITY METERING —\ PARTIAL FLOOR 1 POWER PLAN SCALE: 1 /8"=V-0" GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. ALL CONDUIT IS INTENDED TO BE CONCEALED. CONTRACTOR SHALL PROVIDE TO ARCHITECT/OWNER SHOP DRAWINGS INDICATING ROUTING OF ANY INTENDED EXPOSED CONDUIT PRIOR TO ROUGH -IN FOR ARCHITECT/OWNERS APPROVAL. CONTRACTOR SHALL NOT START ROUGH -IN FOR CONDUIT UNTIL WRITTEN APPROVAL IS RECEIVED. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 4. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. 5. ALL EXTERIOR WALLS ARE TILT -UP CONCRETE. ROUTING OF POWER TO RECEPTACLES WILL BE FROM BELOW FLOOR SLAB. ELECTRICAL NOTES: F�:__> DRINKING FOUNTAIN CONNECTION. MONITOR CONNECTION. MOUNT RECEPTACLE AT +72" ABOVE FINISHED FLOOR. RECEPTACLES ALONG FIRING LINE SHALL BE MOUNTED OVERHEAD AT STRUCTURE. 30A, 208V, 1 PH, RECEPTACLE. COORDINATE NEMA CONFIGURATION WITH OWNER PRIOR TO ORDERING/ROUGH-IN. CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com me 1 / 12/23 w Z Q O O 0 z j F— z 0 O c� v ' J W V Z� W cD O Z 3 OCD 0 Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 PARTIAL FLOOR 1 POWER PLAN E-301 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. a1 V O O N O W N 00 O N N O� N 00 O z a� LL_ E GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. ALL CONDUIT IS INTENDED TO BE CONCEALED. CONTRACTOR SHALL PROVIDE TO ARCHITECT/OWNER SHOP DRAWINGS INDICATING ROUTING OF ANY INTENDED EXPOSED CONDUIT PRIOR TO ROUGH -IN FOR ARCHITECT/OWNERS APPROVAL. CONTRACTOR SHALL NOT START ROUGH -IN FOR CONDUIT UNTIL WRITTEN APPROVAL IS RECEIVED. 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 4. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. ELECTRICAL NOTES: MONITOR CONNECTION. MOUNT RECEPTACLE AT +72" ABOVE FINISHED FLOOR. STACKED DRY -TYPE TRANSFORMERS "T1" AND 172" T1/T2 I PANEL 2P2 PANEL 4M1 PANEL 4L1 u1,3 ELEC. RM 206 3 3 OA DISCONNECT FOR PANELS 2P1, 2P1A DRY-TYF TT3 TRANSF PANEL 2M1 2P2-1,3 FIRE ALARM 1 PANELS 1,3 COMMUNICATIONS J SECURITY) U 2-7 BACKBOARD PANEL A PARTIAL POWER FLOOR PLAN E302J SCALE:1/4"=V-0" 2P2-5 T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com 1/12/23 w Z Q O O 0 z Project No: 2212 100% CONSTRUCTION JANUARY 12, 2023 FLOOR 2 POWER PLAN E-302 FLOOR 2 POWER PLA SCALE: 1 /8"=V-0" a1 CROSS ENGINEERS, INC 19 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. z 0 0 cn 0 O w N 00 O N N N 00 O z a� E N O N N 0 QD O GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. CONDUIT (OR PLENUM RATED CABLE WHERE ALLOWED) AND WIRING IS NOT SHOWN ON THE ELECTRICAL DRAWINGS FOR THE SIGNAL/SYSTEM DEVICES (FIRE ALARM, SECURITY, AND CAMERA) CONTRACTOR SHALL PROVIDE MANUFACTURER'S REQUIRED WIRING IN MINIMUM 3/4"C TO ALL SIGNAL/SYSTEM DEVICES OR PLENUM RATED CABLE WHERE ALLOWED BY CODE. 3. CONNECT FIRE/SMOKE DAMPERS SUPPLIED BY MECHANICAL CONTRACTOR AND POWERED BY 120 VAC FROM SPARE 20A/1-POLE CIRCUIT BREAKER IN NEAREST PANEL THRU A CONTROL RELAY SUCH THAT DAMPERS ARE POWERED OPEN WHEN CONTROL RELAY IS ENERGIZED AND DAMPERS ARE CLOSED WHEN PANEL IS IN ALARM. PROVIDE SMOKE DETECTOR OR DUCT SMOKE DETECTOR WITHIN 5' OF EACH FIRE/SMOKE DAMPER. SEE MECHANICAL PLANS, SCHEDULES AND SPECIFICATIONS FOR FIRE/SMOKE DAMPER LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. 4. CONNECT ALL DOOR HOLDERS AND DOOR CLOSERS SUPPLIED WITH DOOR HARDWARE. THESE ITEMS SHALL BE POWERED BY THE FIRE ALARM CONTROL PANEL WITH 24V THRU A CONTROL RELAY SUCH THAT ALL DOORS RELEASE TO CLOSE WHEN PANEL IS IN ALARM. PROVIDE A SMOKE DETECTOR WITH AUXILIARY RELAY ON EACH SIDE OF DOOR. SEE ARCHITECTURAL PLANS, SCHEDULES AND SPECIFICATIONS FOR FIRE DOOR LOCATIONS. 1 2 3 4 5 5. PROVIDE FIRE ALARM CONDUIT AND WIRE CONNECTION FOR SHUTDOWN OF AIR HANDLING UNIT(S) AND EXHAUST FANS FOR SHUTDOWN ON ALARM AS REQUIRED PER THE UNIFORM MECHANICAL CODE. PROVIDE MONITOR/CONTROL MODULES FOR EXHAUST FANS LOCATED WITHIN 3 FEET OF FAN CONTROLLER, THRU ENERGIZED CONTROL RELAY SUCH THAT THE EXHAUST FANS SHUTDOWN UPON ALARM. SEE MECHANICAL PLANS, SCHEDULES AND SPECIFICATIONS FOR LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. 6. FURNISH DUAL CONTACT DUCT SMOKE DETECTOR, INCLUDING SAMPLING TUBE, TO MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL LOCATE AND MOUNT THE DUCT SMOKE DETECTOR ENCLOSURE/SAMPLING TUBE FOR FIRE ALARM SYSTEM SHUTDOWN. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR SAMPLING TUBE LENGTH AND SIZE REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY CONDUIT (OR PLENUM RATED CABLE WHERE ALLOWED), WIRING, REMOTE INDICATORS AND ACCESSORIES TO SHUTDOWN EACH UNIT UPON ACTIVATION OF THAT UNIT'S SMOKE DETECTOR(S) REQUIRED PER THE MECHANICAL CODE. CONNECTIONS SHALL BE HARDWIRED, INDEPENDENT OF ANY CONTROL SYSTEM LOGIC, SO FAILURE OF THE CONTROL SYSTEM OR LOSS OF CONTROL SYSTEM POWER WILL NOT PREVENT THE FIRE ALARM SYSTEM, SHUTDOWN OF THE UNIT. IN ADDITION TO SHUTTING DOWN THE UNIT WITH THE ALARMED SMOKE DETECTOR, ALL EQUIPMENT INTERLOCKED OR SERVED BY THAT UNIT SHALL BE OFF. OTHER UNITS SHALL ALSO SHUT OFF TO AVOID BUILDING PRESSURE DIFFERENTIALS AND SIMILAR UNDESIRABLE EFFECTS. UPON RESET OF ALARMED DEVICE, SYSTEM SHALL AUTOMATICALLY RETURN TO NORMAL. MECHANICAL CONTRACTOR TO PROVIDE TIME DELAY START OF EQUIPMENT TO PREVENT EXCESS LOAD STARTING AT THE SAME TIME. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE AND CONNECT TO FIRE ALARM CONTROL PANEL. SEE MECHANICAL DRAWINGS, SCHEDULES AND SPECIFICATIONS FOR LOCATIONS. 7. CONTRACTOR SHALL PROVIDE CONDUIT, WIRE, AND CONNECT THE EXTERIOR FIRE ALARM BELL FURNISHED BY THE SPRINKLER CONTRACTOR. THE SPRINKLER SYSTEM IS A DESIGN BUILD SYSTEM. COORDINATE FINAL LOCATION WITH THE SPRINKLER CONTRACTOR. FOR 24V SPRINKLER BELLS, CONNECT THE BELL TO THE FIRE ALARM PANEL. FOR 120V SPRINKLER BELLS, CONNECT TO A DEDICATED SPARE 120V CIRCUIT. 8. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR FIRE WALL SEPARATIONS AND RATINGS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 9. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com 1/12/23 w Z Q O O 0 z j F— z 0 O c� I J W V ZL0 W cD 0 Z Q 3 O CD Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 OVERALL FLOOR 1 SYSTEMS PLAN 1 2 3 4 5 6 E-400 OVRALLFLOOR 1 SYSTEMS PLAN CROSS ENGINEERS, INC All material herein constitutes the original and unpublished work of the architect and SCALE: 1 /16"=1'-0" N 923 MILK Jr. Way Phone: (253) 759-0118 may not be used, duplicated, or disclosed Tacoma, WA 98405 Job Number: 22-082 without the written consent of the info@crossengineers.com architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. a1 V O O V) 0 w N 00 O N N 0 N 00 O z a� LL_ E r� N O N N O QD O WP 71 FI RE ALA A14NUNC a 2 3 4 ❑ ° ° "1 PARTIAL FLOOR 1 SYSTEMS PLAN <2� SCALE: 1/8"=V-0" iy GENERAL NOTES: - 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. CONDUIT (OR PLENUM RATED CABLE WHERE ALLOWED) AND WIRING IS NOT SHOWN ON THE ELECTRICAL DRAWINGS FOR THE SIGNAL/SYSTEM DEVICES (FIRE ALARM, SECURITY, AND CAMERA) CONTRACTOR SHALL PROVIDE MANUFACTURER'S REQUIRED WIRING IN MINIMUM 3/4"C TO ALL SIGNAL/SYSTEM DEVICES OR PLENUM RATED CABLE WHERE ALLOWED BY CODE. 3. CONNECT FIRE/SMOKE DAMPERS SUPPLIED BY MECHANICAL CONTRACTOR AND POWERED BY 120 VAC FROM SPARE 20A/1-POLE CIRCUIT BREAKER IN NEAREST PANEL THRU A CONTROL RELAY SUCH THAT DAMPERS ARE POWERED OPEN WHEN CONTROL RELAY IS ENERGIZED AND DAMPERS ARE CLOSED WHEN PANEL IS IN ALARM. PROVIDE SMOKE DETECTOR OR DUCT SMOKE DETECTOR WITHIN 5' OF EACH FIRE/SMOKE DAMPER. SEE MECHANICAL PLANS, SCHEDULES AND SPECIFICATIONS FOR FIRE/SMOKE DAMPER LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com me 1 / 12/23 4. CONNECT ALL DOOR HOLDERS AND DOOR CLOSERS SUPPLIED WITH DOOR HARDWARE. THESE ITEMS SHALL BE POWERED BY THE FIRE ALARM CONTROL PANEL WITH 24V THRU A CONTROL RELAY SUCH THAT ALL DOORS RELEASE TO CLOSE WHEN PANEL IS IN ALARM. PROVIDE A SMOKE DETECTOR WITH AUXILIARY RELAY ON EACH SIDE OF DOOR. SEE ARCHITECTURAL PLANS, SCHEDULES AND SPECIFICATIONS FOR FIRE DOOR LOCATIONS. 5. PROVIDE FIRE ALARM CONDUIT AND WIRE CONNECTION FOR SHUTDOWN OF AIR HANDLING UNIT(S) AND EXHAUST FANS FOR SHUTDOWN ON ALARM AS REQUIRED PER THE UNIFORM MECHANICAL CODE. PROVIDE MONITOR/CONTROL MODULES FOR EXHAUST FANS LOCATED WITHIN 3 FEET OF FAN CONTROLLER, THRU ENERGIZED CONTROL RELAY SUCH THAT THE EXHAUST FANS SHUTDOWN UPON ALARM. SEE MECHANICAL PLANS, SCHEDULES AND SPECIFICATIONS FOR LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. 6. FURNISH DUAL CONTACT DUCT SMOKE DETECTOR, INCLUDING SAMPLING TUBE, TO MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL LOCATE AND 0 MOUNT THE DUCT SMOKE DETECTOR ENCLOSURE/SAMPLING TUBE FOR FIRE ALARM SYSTEM SHUTDOWN. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR SAMPLING TUBE LENGTH AND SIZE 0 REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY CONDUIT (OR PLENUM RATED CABLE WHERE ALLOWED), WIRING, REMOTE INDICATORS Q AND ACCESSORIES TO SHUTDOWN EACH UNIT UPON ACTIVATION OF THAT UNIT'S SMOKE DETECTOR(S) REQUIRED PER THE MECHANICAL CODE. CONNECTIONS :z SHALL BE HARDWIRED, INDEPENDENT OF ANY CONTROL SYSTEM LOGIC, SO _ FAILURE OF THE CONTROL SYSTEM OR LOSS OF CONTROL SYSTEM POWER WILL NOT PREVENT THE FIRE ALARM SYSTEM, SHUTDOWN OF THE UNIT. IN ADDITION TO SHUTTING DOWN THE UNIT WITH THE ALARMED SMOKE DETECTOR, ALL U EQUIPMENT INTERLOCKED OR SERVED BY THAT UNIT SHALL BE OFF. OTHER 7 L 0 UNITS SHALL ALSO SHUT OFF TO AVOID BUILDING PRESSURE DIFFERENTIALS AND SIMILAR UNDESIRABLE EFFECTS. UPON RESET OF ALARMED DEVICE, SYSTEM SHALL AUTOMATICALLY RETURN TO NORMAL. MECHANICAL Q 3 CONTRACTOR TO PROVIDE TIME DELAY START OF EQUIPMENT TO PREVENT O EXCESS LOAD STARTING AT THE SAME TIME. CONTRACTOR SHALL PROVIDE w CONDUIT AND WIRE AND CONNECT TO FIRE ALARM CONTROL PANEL. SEE MECHANICAL DRAWINGS, SCHEDULES AND SPECIFICATIONS FOR LOCATIONS. 7. CONTRACTOR SHALL PROVIDE CONDUIT, WIRE, AND CONNECT THE EXTERIOR L, D CD o FIRE ALARM BELL FURNISHED BY THE SPRINKLER CONTRACTOR. THE 7 Q Z SPRINKLER SYSTEM IS A DESIGN BUILD SYSTEM. COORDINATE FINAL LOCATION 3 WITH THE SPRINKLER CONTRACTOR. FOR 24V SPRINKLER BELLS, CONNECT THE OCD BELL TO THE FIRE ALARM PANEL. FOR 120V SPRINKLER BELLS, CONNECT TO A o r DEDICATED SPARE 120V CIRCUIT. 8. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR FIRE WALL Project No: 2212 SEPARATIONS AND RATINGS. CONTRACTOR SHALL PROVIDE CAULKING, 100% CONSTRUCTION SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. JANUARY 12, 2023 9. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. ELECTRICAL NOTES: MONITOR CONNECTION. MOUNT DATA PARTIAL OUTLET AT +72" ABOVE FINISHED FLOOR. FLOOR CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com SYSTEMS PLAN E-401 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. a1 V O O Ln N O w N 00 O N N O� 0 N 00 O z a� LL_ E r� r� N O N N O QD O FLOOR 2 SYSTEMS PLAN SCALE: 1 /8"=V-0" N GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, LANDSCAPE, CIVIL AND MECHANICAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, LANDSCAPE AND MECHANICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS WORK IN THE BID. 2. CONDUIT (OR PLENUM RATED CABLE WHERE ALLOWED) AND WIRING IS NOT SHOWN ON THE ELECTRICAL DRAWINGS FOR THE SIGNAL/SYSTEM DEVICES (FIRE ALARM, SECURITY, AND CAMERA) CONTRACTOR SHALL PROVIDE MANUFACTURER'S REQUIRED WIRING IN MINIMUM 3/4"C TO ALL SIGNAL/SYSTEM DEVICES OR PLENUM RATED CABLE WHERE ALLOWED BY CODE. 3. CONNECT FIRE/SMOKE DAMPERS SUPPLIED BY MECHANICAL CONTRACTOR AND POWERED BY 120 VAC FROM SPARE 20A/1-POLE CIRCUIT BREAKER IN NEAREST PANEL THRU A CONTROL RELAY SUCH THAT DAMPERS ARE POWERED OPEN WHEN CONTROL RELAY IS ENERGIZED AND DAMPERS ARE CLOSED WHEN PANEL IS IN ALARM. PROVIDE SMOKE DETECTOR OR DUCT SMOKE DETECTOR WITHIN 5' OF EACH FIRE/SMOKE DAMPER. SEE MECHANICAL PLANS, SCHEDULES AND SPECIFICATIONS FOR FIRE/SMOKE DAMPER LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com 1/12/23 4. CONNECT ALL DOOR HOLDERS AND DOOR CLOSERS SUPPLIED WITH DOOR HARDWARE. THESE ITEMS SHALL BE POWERED BY THE FIRE ALARM CONTROL PANEL WITH 24V THRU A CONTROL RELAY SUCH THAT ALL DOORS RELEASE TO - CLOSE WHEN PANEL IS IN ALARM. PROVIDE A SMOKE DETECTOR WITH AUXILIARY RELAY ON EACH SIDE OF DOOR. SEE ARCHITECTURAL PLANS, SCHEDULES AND SPECIFICATIONS FOR FIRE DOOR LOCATIONS. 5. PROVIDE FIRE ALARM CONDUIT AND WIRE CONNECTION FOR SHUTDOWN OF AIR HANDLING UNIT(S) AND EXHAUST FANS FOR SHUTDOWN ON ALARM AS REQUIRED PER THE UNIFORM MECHANICAL CODE. PROVIDE MONITOR/CONTROL MODULES FOR EXHAUST FANS LOCATED WITHIN 3 FEET OF FAN CONTROLLER, THRU ENERGIZED CONTROL RELAY SUCH THAT THE EXHAUST FANS SHUTDOWN UPON ALARM. SEE MECHANICAL PLANS, SCHEDULES AND SPECIFICATIONS FOR LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. 6. FURNISH DUAL CONTACT DUCT SMOKE DETECTOR, INCLUDING SAMPLING TUBE, TO MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL LOCATE AND 0 MOUNT THE DUCT SMOKE DETECTOR ENCLOSURE/SAMPLING TUBE FOR FIRE ALARM SYSTEM SHUTDOWN. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR SAMPLING TUBE LENGTH AND SIZE 0 REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY CONDUIT (OR PLENUM RATED CABLE WHERE ALLOWED), WIRING, REMOTE INDICATORS Q AND ACCESSORIES TO SHUTDOWN EACH UNIT UPON ACTIVATION OF THAT UNIT'S SMOKE DETECTOR(S) REQUIRED PER THE MECHANICAL CODE. CONNECTIONS ]z SHALL BE HARDWIRED, INDEPENDENT OF ANY CONTROL SYSTEM LOGIC, SO _ FAILURE OF THE CONTROL SYSTEM OR LOSS OF CONTROL SYSTEM POWER WILL NOT PREVENT THE FIRE ALARM SYSTEM, SHUTDOWN OF THE UNIT. IN ADDITION TO SHUTTING DOWN THE UNIT WITH THE ALARMED SMOKE DETECTOR, ALL U EQUIPMENT INTERLOCKED OR SERVED BY THAT UNIT SHALL BE OFF. OTHER 70 L UNITS SHALL ALSO SHUT OFF TO AVOID BUILDING PRESSURE DIFFERENTIALS AND SIMILAR UNDESIRABLE EFFECTS. UPON RESET OF ALARMED DEVICE, _ SYSTEM SHALL AUTOMATICALLY RETURN TO NORMAL. MECHANICAL Q 3 CONTRACTOR TO PROVIDE TIME DELAY START OF EQUIPMENT TO PREVENT O EXCESS LOAD STARTING AT THE SAME TIME. CONTRACTOR SHALL PROVIDE w CONDUIT AND WIRE AND CONNECT TO FIRE ALARM CONTROL PANEL. SEE MECHANICAL DRAWINGS, SCHEDULES AND SPECIFICATIONS FOR LOCATIONS. 7. CONTRACTOR SHALL PROVIDE CONDUIT, WIRE, AND CONNECT THE EXTERIOR L,, V CD o FIRE ALARM BELL FURNISHED BY THE SPRINKLER CONTRACTOR. THE 7 Q Z SPRINKLER SYSTEM IS A DESIGN BUILD SYSTEM. COORDINATE FINAL LOCATION 3 WITH THE SPRINKLER CONTRACTOR. FOR 24V SPRINKLER BELLS, CONNECT THE OCD BELL TO THE FIRE ALARM PANEL. FOR 120V SPRINKLER BELLS, CONNECT TO A o r DEDICATED SPARE 120V CIRCUIT. 8. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR FIRE WALL Project No: 2212 SEPARATIONS AND RATINGS. CONTRACTOR SHALL PROVIDE CAULKING, 100% CONSTRUCTION SEAL -OFFS, RATED PENETRATION BLOCK -OUTS, ETC. REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. JANUARY 12, 2023 9. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. ELECTRICAL NOTES: MONITOR CONNECTION. MOUNT DATA FLOOR 2 OUTLET AT +72" ABOVE FINISHED FLOOR. SYSTEMS PLAN CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com E-402 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. a1 GROUND ROD PROTECTOR BASE PW PIPE #12R12A WITH COVER OR EQUAL FINISHED GRADE -\ 10'-0" x 3/4" COPPER CLAD STEEL GROUND RODS SPACED NO LESS THAN 10 FEET APART MINIMUM OF TWO (2) 0 U 0 O Ln w N 00 O z I MAIN DISTRIBUTION PANELBOARD FOR BUILDING ELECTRICAL BUILDING SERVICE GROUND STEEL NEUTRALBUS I I GROUNDBUS #3/0 BARE CU #6 BARE CU BONDING JUMPER #4 BARE CU COLD WATER LINE/GAS LINE/ FIRE SUPPRESSION WATERLINE, TYPICAL WATER METER/GAS METER FIRE SUPPRESSION VALVES #3/0 BARE CU #2 BARE CU TO UFER GROUND. CONNECT TO BUILDING FOUNDATION REBAR MINIMUM CONTINUOUS FOR 20' OR CONTINUOUS BARE COPPER CONDUCTOR IN BUILDING FOUNDATION BUILDING SERVICE GROUNDING TYPICAL NO SCALE NOTES: 1. CONTRACTOR MAY SIZE WIRES PER NEC 250.66 AND 250.104 IF SMALLER SIZES ARE ALLOWED PER THE NEC. 2. CONTRACTOR SHALL PROVIDE GROUNDING SHOP DRAWING FOR REVIEW. SHOP DRAWING SHALL INCLUDE SCALED SITE PLAN AND/OR FLOOR PLAN LOCATIONS OF GROUND RODS, GROUND WELLS, STEEL GROUNDING POINT(S), WATER PIPE GROUNDING, GROUND BARS, UFER GROUND AND BONDING. CONNECT TO CONDUIT GROUND BUSHING ON ELECTRICAL SERVICE ENTRANCE CONDUITS. 0 CONNECT TO CONDUIT GROUND BUSHING ON TELECOMMUNICATION SERVICE CONDUITS. 0 45KVA, 480:120/208V, 3PH, 4W, DRY -TYPE TRANSFORMER. 112.5KVA, 480:120/208V, 3PH, 4W, DRY -TYPE TRANSFORMER. O sr PANEL PANEL PANEL PANEL 2 M 1 �o,� 4 M 1 4 L 1 s2�6 T 2 P2 V 300A T3 400A 100A T2 S 100A GRD- -GRD 7 3 4 5 4 % 400AS T1 300AF 6 _ GRD '?,s 1000AMP, NEMA 3R, UTILITY METERING s CABINET PER PSE STANDARDS AND 6 7 8 PUGET SOUND REQUIREMENTS ENERGY (PSE), O PANEL 11,245 PANEL PANEL VAULT MOUNTED, MDP 2P1 2P1A TRANSFORMER T T V AIC = 26,100 S S 1000A S S 300A 300A TRANS. 3� - GRID 112.5KVA, 480:120/208V, 3PH, TO PSE CONNECTION 4W, DRY -TYPE TRANSFORMER. POINT 1 2 2 POWER RISER DIAGRAM NO SCALE SURFACE MOUNTING PANEL SCHEDULE 28,000 AIC NO. MDP LOCATION: ELECTRICAL CLOSET SERVING: BUILDING 480/277 VOLTS 3PHASE 4WIRE 1000 AMPS WITH 1000 MAIN BREAKER CKT NO. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 PANEL 4M1 242.00 400 3 100 3 150 3 150 3 I 150 ' 3 60 3 30 3 150 3 68.50 PANEL 2P1/2P1A VIA 2 3 112.5KVA XFMR 4 5 6 7 PANEL 4L1 17.70 20.60 PANEL 2P2 VIA 8 9 45KVA XFMR 10 11 12 13 PANEL 2M1 VIA 98.20 TVSS 14 15 112.5KVA XFMR 16 17 18 19 CU-1 99.60 99.60 CU-2 20 21 22 23 24 26 25 SPACE SPACE 27 SPACE SPACE 28 29 ISPACE SPACE 1 30 REMARKS: CONNECTED LOAD: 646.1 KVA 778 AMPS DEMAND LOAD: 676.7 KVA 815 AMPS PANEL MDP LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING 17.67 X 1.25 220.19(A)(1) = 22.09 RECEPTS TO 10KW 10.00 X 1.00 220.44 = 10.00 RECEPTS OVER 10KW 10.70 X 0.50 220.44 = 5.35 MOTORS (LARGEST) 99.60 X 1.25 430.24 = 124.50 MOTORS 399.42 X 1.00 430.24 = 399.42 KITCHEN EQUIP. - X 1.00 220.56 = EV CHARGERS 26.60 X 1.25 = 33.25 AIR CONDITIONING - X 1.00 220.50 = ELECTRIC HEAT 34.00 X 1.00 220.51 = 34.00 MISCELLANEOUS 48.12 X 1.00 = 48.12 TOTAL CONNECTED 646.1 KVA (778 AMPS) CONDUIT AND CONDUCTOR SCHEDULE A(1)4"C- CONDUCTORS BY PSE A(3)4"C-(4)#600 KCM AL EACH A (2)2-1/2"C-(4)#250 KCM AL & (1)#1 AL GRID EACH 1-1/2"C-(4)#1 AL & (1)#6 AL GRID A 1 "C-(3)#6 CU & (1)#10 CU GRID A 2"C-(3)#3/0 AL & (1)#4 AL GRID A 4"C-(4)#500 KCM AL & (1)#1/0 AL GRID A4"C-(4)#500 KCM AL & (1)#2 AL GRID TOTAL DEMAND 676.7 KVA (815 AMPS) CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com M2/23 w Z Q 0 0 z j F- z 0 � O = c� Q v ' J W V ZL0 w CD 0 Z O 0 Q 0 o� Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 POWER RISER DIAGRAM E-500 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. (D O A O O Cn CY) 0 Ln w N 00 O N N 0 00 O :: SURFACE MOUNTING PANEL SCHEDULE 28,000 AIC NO. 4M1 LOCATION: ELECTRICAL 206 SERVING: MECHANICAL 480/277 VOLTS 3PHASE 4WIRE 400 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP E7TRIP AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 FFU-1 28.22 60 3 60 3 60 3 ;!3 20 3 60 3 60 3 60 3 60 3 It3 28.22 FFU-2 2 3 4 5 6 7 FFU-1 28.22 28.22 FFU-2 8 9 10 11 12 13 FFU-1 28.22 28.22 FFU-2 14 15 16 17 18 19 FFU-1 28.22 28.22 FFU-2 20 21 22 23 24 25 ERV-101,102 8.13 8.13 ERV-201,202 26 27 28 29 30 31 SPACE SPACE 32 33 34 35 36 37 38 39 ► 40 41 SPACE SPACE 42 REMARKS: CONNECTED LOAD: 242.0 KVA 292 AMPS DEMAND LOAD: 249.1 KVA 300 AMPS PANEL 4M1 LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING - X 1.25 220.19(A)(1) _ RECEPTS TO 10KW - X 1.00 220.44 = RECEPTS OVER 10KW - X 0.50 220.44 = MOTORS (LARGEST) 28.22 X 1.25 430.24 = 35.28 MOTORS 213.80 X 1.00 430.24 = 213.80 KITCHEN EQUIP. - X 1.00 220.56 = WELDERS X 1.00 630.11(B) _ AIR CONDITIONING X 1.00 220.50 = ELECTRIC HEAT X 1.00 220.51 = MISCELLANEOUS X 1.00 = TOTAL CONNECTED 242.0 KVA (292 AMPS) TOTAL DEMAND 249.1 KVA (300 AMPS) SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC NO. 2P1A LOCATION: ELECTRICAL CLOSET SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 1 300 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 FIRING LINE RECEPTACLE 1.00 20 20 40 7 2 40 2 20 20 40 2 40 2 1.00 FIRING LINE RECEPTACLE 2 3 1.00 1.00 4 5 1.00 1.00 6 7 1.00 1.00 8 9 FIRING LINE RECEPTACLE 1.00 1.00 10 11 RECEPTACLES - EXTERIOR .54 1.00 FIRING LINE RECEPTACLE 12 13 SPARE SPARE 14 15 16 17 18 19 20 21 22 23 SPARE SPARE 24 25 SPACE SPACE 26 27 28 29 30 31 32 33 SPACE SPACE 34 35 EV CHARGER 6.65 6.65 EV CHARGER 36 37 38 39 EV CHARGER 6.65 6.65 EV CHARGER 40 41 42 REMARKS:. CONNECTED LOAD: 38.1 KVA 106 AMPS DEMAND LOAD: 44.8 KVA 124 AMPS * SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC NO. 4L1 LOCATION: ELECTRICAL 206 SERVING: LIGHTING 480/277 VOLTS 3PHASE 4WIRE 100 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 LIGHTS -1ST FLOOR 3.40 20 11 20 20 20 2.10 LIGHTS - EXTERIOR 2 3 LIGHTS - 25M RANGE 2.78 3.27 LIGHTS - 2ND FLOOR 4 5 LIGHTS -100M RANGE 3.04 SPARE 6 7 LIGHTS -100M RANGE 3.08 SPARE 8 9 SPARE SPARE 10 11 SPARE SPACE 12 13 SPACE 14 15 16 17 18 19 SPACE I SPACE 20 REMARKS: CONNECTED LOAD: 17.7 KVA 21 AMPS DEMAND LOAD: 22.1 KVA 27 AMPS PANEL 41-1 LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING 17.67 X 1.25 220.19(A)(1) = 22.09 RECEPTS TO 10KW - X 1.00 220.44 = RECEPTS OVER 10KW X 0.50 220.44 = MOTORS (LARGEST) X 1.25 430.24 = MOTORS X 1.00 430.24 = KITCHEN EQUIP. X 1.00 220.56 = WELDERS X 1.00 630.11(B) _ AIR CONDITIONING X 1.00 220.50 = ELECTRIC HEAT X 1.00 220.51 = MISCELLANEOUS X 1.00 = TOTAL CONNECTED 17.7 KVA (21 AMPS) TOTAL DEMAND 22.1 KVA (27 AMPS) SURFACE MOUNTING PANEL SCHEDULE 10,000 AIC NO. 2P2 LOCATION: ELECTRICAL 206 SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 1 100 AMPS WITH 100 MAIN BREAKER CKT NO. LOAD DESCRIPTION KVA TRIP TRIP AMPS KVA LOAD DESCRIPTION CKT NO. 1 3 RECEPTACLES - 206 .54 20 20 ;�20 2 20 2 20 11 20 30 3 1.00 MONITOR(S) - 201 2 RECEPTACLES-206 .36 1.00 4 5 FIRE ALARM 1.00 1.00 6 7 SECURITY 1.00 1.00 8 9 RECEPTACLES - 201,205 .72 1.00 11 10 11 RECEPTACLES - 201,205 .72 1.00 MONITOR S - 201 12 13 RECEPTACLES - 201,204 .54 .72 RECEPTACLES - 201 14 15 RECEPTACLES - 201,204 .54 .72 16 17 RECEPTACLES - 201,204 .54 .72 18 19 RECEPTS. - 201,202 203 208 .72 .54 11 20 21 RECEPTS. - 201,202,203,208 .54 .54 RECEPTACLES - 201 22 23 ROOF RECEPTACLES .72 SPARE 24 25 SPARE SPARE 26 27 SPARE 28 29 SPACE 30 31 1111, 1 32 33 SPARE 11, 34 35 BC-100 CC-204 1.04 SPACE 36 37 TVSS 38 39 FC-201 A,201 B,201 C 2.29 40 41 42 REMARKS:. CONNECTED LOAD: 20.6 KVA 57 AMPS DEMAND LOAD: 21.1 KVA 59 AMPS * PROVIDE CIRCUIT BREAKER HANDLE LOCK. SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC NO. 2P1 LOCATION: ELECTRICAL CLOSET SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 400 AMPS WITH 300 MAIN BREAKER CKT NO. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 RECEPTACLES-101,103 .72 20 20 Aq 20 2 30 2 30 Z 2 20 20 30 3 3.50 RECEPTACLES -111 2 3 RECEPTACLES-101,103 .54 4 6 5 RECEPTACLES -102 .90 3.50 RECEPTACLES -111 7 RECEPTACLES -102 .90 8 9 RECEPTACLES-100,101 .72 .72 RECEPTACLES -110 10 11 RECEPTACLES-100,101 .72 .72 RECEPTACLES -110 12 13 MONITOR -101 .50 .90 RECEPTACLES-107,112,113 14 15 RECEPTACLES -101 .36 .90 RECEPTACLES-107,112,113 16 17 VENDING -101 1.50 .72 RECEPTACLES-108,114,115 18 19 VENDING -101 1.50 .72 RECEPTACLES-108,114,115 20 21 RECEPTACLES-101,104 .90 .54 RECEPTACLES-108,114,115 22 23 DRINKING FOUNTAIN -101 .90 SPARE 24 25 RECEPTACLES -111 1.00 SPARE 26 27 RECEPTACLES -111 1.00 SPACE 28 29 RECEPTACLES -111 1.00 30 31 SPARE 32 33 SPARE 34 35 CC-102,108A,108B, 2.70 SPACE 36 37 110,111,112 - TVSS 38 39 CC-113, FC-101 A,101 B,101 C 2.70 40 41 1 1 42 REMARKS: PROVIDE FEED THRU LUGS TO PANEL 2P1A. CONNECTED LOAD: 68.5 KVA 190 AMPS DEMAND LOAD: 75.1 KVA 209 AMPS * PROVIDE GFI CIRCUIT BREAKER. SERVICE LIGHTING RECEPTS TO 10KW RECEPTS OVER10KW MOTORS (LARGEST) MOTORS KITCHEN EQUIP. EV CHARGERS AIR CONDITIONING ELECTRIC HEAT MISCELLANEOUS PANEL 2P1 LOAD CALCULATIONS KVA LOAD FACTOR NEC REF. DEMAND LOAD - X 1.25 220.19(A)(1) _ 10.00 X 1.00 220.44 = 10.00 1.52 X 0.50 220.44 = .76 2.70 X 1.25 430.24 = 3.38 2.70 X 1.00 430.24 = 2.70 - X 1.00 220.56 = 26.60 X 1.25 = 33.25 - X 1.00 220.50 = - X 1.00 220.51 = 25.00 X 1.00 = 25.00 TOTAL CONNECTED 68.5 KVA (190 AMPS) TOTAL DEMAND 75.1 KVA (209 AMPS) SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC NO. 2M1 LOCATION: ELECTRICAL 206 SERVING: EQUIPMENT 120/208 VOLTS 3PHASE 4WIRE 1 400 AMPS WITH 300 MAIN BREAKER CKT NO. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 HP-1 17.64 �3- 30 3 20 2 )027�1 30 2 30 2jj� 0;' 1;3 30 3 60 3 20 30 2 30 2 30 2 30 2 17.64 HP-1 2 3 4 5 6 7 MAU-1 6.76 6.76 MAU-2 8 9 10 11 12 13 EWH-1 2.00 15.12 WH-1 14 15 16 17 RH-1 4.00Aa--- 18 19 .27 CP-1 20 21 RH-2 4.00 4.00 RH-5 22 23 24 25 RH-3 4.00 4.00 RH-6 26 27 28 29 RH-4 4.00 4.00 RH-7 30 31 32 33 SPACE 4.00 RH-8 34 35 36 37 SPACE 38 39 SPACE 40 41 SPACE I SPACE 42 REMARKS: . CONNECTED LOAD: 98.2 KVA 273 AMPS DEMAND LOAD: 102.6 KVA 285 AMPS PANEL 2P1A LOAD CALCULATIONS PANEL 2M1 LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD PANEL 2P2 LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING - X 1.25 220.19(A)(1) _ - LIGHTING X 1.25 220.19(A)(1) _ - RECEPTS TO 10KW .54 X 1.00 220.44 = .54 LIGHTING - X 1.25 220.19(A)(1) - RECEPTS TO 10KW X 1.00 220.44 = RECEPTS OVER 10KW - X 0.50 220.44 = - RECEPTS TO 10KW 9.18 X 1.00 220.44 = 9.18 RECEPTS OVER 10KW X 0.50 220.44 = MOTORS (LARGEST) X 1.25 430.24 = RECEPTS OVER 10KW - X 0.50 220.44 = - MOTORS (LARGEST) 17.64 X 1.25 430.24 = 22.05 MOTORS X 1.00 430.24 = MOTORS (LARGEST) 2.29 X 1.25 430.24 = 2.86 MOTORS 31.43 X 1.00 430.24 = 31.43 KITCHEN EQUIP. X 1.00 220.56 = - MOTORS 1.04 X 1.00 430.24 = 1.04 KITCHEN EQUIP. - X 1.00 220.56 = EV CHARGERS 26.60 X 1.25 = 33.25 KITCHEN EQUIP. - X 1.00 220.56 = - WELDERS X 1.00 630.11(B) _ AIR CONDITIONING - X 1.00 220.50 = - WELDERS X 1.00 630.11(B) = AIR CONDITIONING X 1.00 220.50 = ELECTRIC HEAT - X 1.00 220.51 = - AIR CONDITIONING X 1.00 220.50 = ELECTRIC HEAT 34.00 X 1.00 220.51 = 34.00 MISCELLANEOUS 11.00 X 1.00 = 11.00 ELECTRIC HEAT X 1.00 220.51 = - MISCELLANEOUS 15.12 X 1.00 = 15.12 MISCELLANEOUS 8.00 X 1.00 = 8.00 TOTAL CONNECTED 38.1 KVA TOTAL DEMAND 44.8 KVA TOTAL CONNECTED 98.2 KVA TOTAL DEMAND 102.6 KVA (106 AMPS) (124 AMPS) TOTAL CONNECTED 20.6 KVA TOTAL DEMAND 21.1 KVA (273 AMPS) (285 AMPS) (57 AMPS) (59 AMPS) T H O M A S architecture studios 525 COLUMBIA ST. I OLYMPIA, WA 98501 360.915.8775 1 tasolympia.com me 1/12/23 w Z Q 0 0 z U Z 10 O c/0) v ' J w V ZL0 w CD 0 Z O Q 3 0- Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 PANEL SCHEDULES E-501 QD O n Ad CROSS ENGINEERS, INC 923 MLK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 19 info@crossengineers.com All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. N O Ln w N 00 O N N 0 00 O z Q� E l� l� N O N N 0 Q� O MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE ITEM DESCRIPTION LOCATION VOLTS PHASE HP KW MIN. CIRCUIT AMPS DISC. SWITCH FUSES MAGNETIC STARTER FEEDER CIRCUIT NUMBER NOTES BC 10o BRANCH CONTROLLER UTILITY 208 208 1 - - 2 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-27,29 CC 102 VRF INDOOR CEILING UNIT TRAINING 102 208 1 - - 3 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-35,37 CC 1oa VRF INDOOR CEILING UNIT HALL 108 208 1 - - 2 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-35,37 CC 108B CC 110 VRF INDOOR CEILING UNIT VRF INDOOR CEILING UNIT HALL 108 RSO 110 208 1 - - 2 - - 3/4"C-2#12 CU & 1#12 CU GIRD 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-35,37 208 1 - - 2 - - 2P1-35,37 CC 111 VRF INDOOR CEILING UNIT MAINTENANCE 111 208 1 - - 2 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-35,37 CC 112 VRF INDOOR CEILING UNIT RSO 112 208 1 - - 2 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-35,37 CC 113 VRF INDOOR CEILING UNIT STORAGE 113 208 1 - - 2 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-39,41 CC 204 VRF INDOOR CEILING UNIT MANAGER 204 208 1 - - 3 � - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P2-35,37 CP 1 CIRCULATION PUMP MECHANICAL CLOSET 120 1 - .27 2.3 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2M1-20 CU 1 CONDENSING UNIT CONDENSING UNIT ROOF ROOF 480 3 - - 120 3P200 NEMA 3R 150 - 2-1/2"C-3#250 KCM AL & 1#4 AL GIRD MDP-19, 21,23 MDP-20, 22,24 CU 2 480 3 - - 120 3P200 NEMA 3R 150 - 2-1/2"C-3#250 KCM AL & 1#4 AL GIRD R 101 ENERGY RECOV. VENTILATOR STORAGE 103 480 3 - - 2.8 3P30 15 - 3/4"C-3#12 CU & 1#12 CU GIRD 4M1-25, 27,29 ER 102 ENERGY RECOV. VENTILATOR LOCKERS 104 480 3 - - 2.8 3P30 15 - 3/4"C-3#12 CU & 1#12 CU GIRD 4M1-25, 27,29 ER 201 ENERGY RECOV. VENTILATOR STORAGE 205 480 3 - - 2.8 3P30 15 - 3/4"C-3#12 CU & 1#12 CU GIRD 4M1-26, 28,30 ER 202 ENERGY RECOV. VENTILATOR UTILITY 208 480 3 - - 2.8 3P30 15 - 3/4"C-3#12 CU & 1#12 CU GIRD 4M1-26, 28,30 W 1 ELECTRIC WALL HEATER VESTIBULE 100 O 3/4"C-2#12 CU & 1#12 CU GIRD 208 1 - 2.00 9.6 - - 2M1-13,15 FC 101 VRF INDOOR FAN COIL LOCKERS 104 208 1 - - 3 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-39,41 FC 101B FC 101C VRF INDOOR FAN COIL VRF INDOOR FAN COIL STORAGE 103 STORAGE 103 208 1 - - 4 O - - 3/4"C-2#12 CU & 1#12 CU GIRD 3/4"C-2#12 CU & 1#12 CU GIRD 2P1-39,41 208 1 - - 4 - - 2P1-39,41 FC 01 VRF INDOOR FAN COIL STORAGE 205 208 1 - - 3 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P2-39141 FC o1B VRF INDOOR FAN COIL STORAGE 205 208 1 - - 4 - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P2-39,41 FC o1C VRF INDOOR FAN COIL UTILITY 208 208 1 - - 4 � - - 3/4"C-2#12 CU & 1#12 CU GIRD 2P2-39,41 FFU 1 FAN FILTER UNIT ROOF 480 3 (4)25 - (4)34 (4)3P60 NEMA 3R (4)60 - (4)1"C-3#6 CU & 1#10 CU GIRD O O FFU 2 FAN FILTER UNIT ROOF 480 3 (4)25 - (4)34 (4)3P60 NEMA 3R (4)60 - (4)1"C-3#6 CU & 1#10 CU GIRD O O MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE HP MIN. ITEM DESCRIPTION LOCATION VOLTS PHASE CIRCUIT DISC. FUSES MAGNETIC FEEDER CIRCUIT NOTES KW AMPS SWITCH STARTER NUMBER HP HEAT ROOF 208 3 - 49 3P100 80 - 1-1/2"C-3#2 CU 2M1-1,3,5 0 1 PUMP - & 1#8 CU GIRD 2M1-2,4,6 A MAKE-UP ROOF 208 3 - 18.8 3P30 30 - 3/4"C-3#10 CU 2M1-7, O 1 AIR UNIT - NEMA 3R 3P30 & 1#10 CU GIRD 9,11 A MAKE-UP ROOF 208 3 - 18.8 30 - 3/4"C-3#10 CU 2M1-8, 0 2 AIR UNIT - NEMA 3R & 1#10 CU GIRD 10,12 RH RADIANT 100 METER O - 3/4"C-2#10 CU 208 1 - 19.2 - 2M1-17,19 1 HEATER RANGE 114 4.00 & 1#10 CU GIRD RH RADIANT 100 METER 208 1 A4.00 19.2 - - 3/4"C-2#10 CU 2M1-21,23 HEATER RANGE114 & 1#10 CU GIRD RH RADIANT 100 METER 208 1 Z4.00 19.2 O - - 3/4"C-2#10 CU 2M1-25,27 HEATER RANGE114 & 1#10 CU GIRD RH RADIANT 100 METER 208 1 -Z4O 19.2 0 - - 3/4"C-2#10 CU 2M1-29,31 4 HEATER RANGE 114 0 & 1#10 CU GIRD RH RADIANT 25 METER 208 1 - 19.2 O - - 3/4"C-2#10 CU 2M1-22,24 5 HEATER RANGE 115 4.00 & 1#10 CU GIRD RH RADIANT 25 METER 208 1 - 19.2 O - - 3/4"C-2#10 CU 2M1-26,28 s HEATER RANGE 115 4.00 & 1#10 CU GIRD RH RADIANT 25 METER 208 1 - Z4OO 19.2 0 - - 3/4"C-2#10 CU 2M1-30,32 7 HEATER RANGE 115 & 1#10 CU GIRD RH RADIANT 25 METER (2)& 3/4"C-2#10 CU 2M1-34,36 208 1 - 19.2 - - s HEATER RANGE 115 4.00 1#10 CU GIRD WH WATER MECHANICAL 3P30 60 1"C-3#6 CU 2M1-14, 208 3 - 42 - 1 HEATER CLOSET - & 1#10 CU GIRD 16,18 T H O M A S architecture studios 525 COLUMBIA ST. I OLYMPIA, WA 98501 360.915.8775 1 tasolympia.com me 1 / 12/23 w Z Q O O 0 z MECHANICAL EQUIPMENT CONNECTION SCHEDULES NOTES: U O PROVIDE 20A MOTOR RATED TOGGLE SWITCH Z 0 O QUANTITY OF FOUR(4) CONNECTIONS. Q3 O 3 O PROVIDE DUCT SMOKE DETECTOR. ELECTRICAL CONTRACTOR SHALL FURNISH DUCT SMOKE DETECTOR TO MECHANICAL CONTRACTOR FOR LOCATE AND INSTALLATION. ALL CONNECTIONS TO FIRE ALARM BY = w� ELECTRICAL CONTRACTOR. (/) O CONNECT FAN FILTER UNITS TO THE FOLLOWING CIRCUITS: V Z� V) CD PANEL 4M1, CIRCUITS #1,3,5 PANEL 4M1, CIRCUITS #7,9,11 Z Q PANEL 4M1, CIRCUITS #13,15,17 O 0 CDPANEL 4M1, CIRCUITS #19,21,23 � CONNECT FAN FILTER UNITS TO THE FOLLOWING CIRCUITS: PANEL 4M1, CIRCUITS #2,4,6 PANEL 4M1, CIRCUITS #8,10,12 Project No: 2212 PANEL 4M1, CIRCUITS #14,16,18 1007o CONSTRUCTION PANEL 4M1, CIRCUITS #20,22,24 JANUARY 12, 2023 O QUANTITY OF TWO(2) CONNECTIONS. U PROVIDE 30A MOTOR RATED TOGGLE SWITCH. CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com ELECTRICAL SCHEDULES E-502 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. t1 w O U 0) 0 Ln w N 00 O z a� LL_ E Q 00 N O N N LIGHTING CONTROL SCHEDULE - 1ST FLOOR ROOM NUMBER/NAME 1/0 CONTROLLER ID TYPE OF CONTROL REMARKS OCCUPANCY SENSOR PHOTO SENSOR DIMMING SWITCHING VESTIBULE 100 a N N Y D 00 PRO SHOP 101 a N N Y D 00 b N N Y D OQ TRAINING 102 a Y Y Y Y D OOQ b Y Y D 000 Y STORAGE 103 a N N 0 00 LOCKERS 104 a Y N N 0 O LANE ENTRY 107 a N N N 0 OQ HALL 108 a N N N 0 OO STAIR 109 a N N N 0 OO RS0110 a Y N Y D 00 MAINTENANCE 111 a Y N N 0 W RS0112 a Y N Y D 00 100 METER RANGE 114 a N N Y D 00 b N N Y D 00 C N N Y D 00 d N N Y D 012 e N N Y D 1012 f N N Y D O ,s N N Y D 00 25 METER RANGE 115 a N N Y D 00 b N N Y D 00 C N N Y D 100 EXTERIOR a N N N N/A 17 b N N N N/A 17 C N N N N/A 17 TRAINING 201 a N N Y D O b N Y Y D OOQ C N Y Y D OW OFFICE 204 a Y Y Y D OOQ b Y Y Y D @@@ STORAGE 205 a Y N N 0 O UTILITY 208 a Y N N 0 O GENERAL NOTES: 1. LIGHTING CONTROLS SHALL BE WIRELESS ENCELIUM EDGE, WIRELESS LUTRON VIVE, OR WIRELESS EATON WAVELINX. 2. FOR ALL DIMMING SWITCHES WHEN ROOM LIGHTS ARE TURNED OFF LIGHTS SHALL REVERT BACK TO FULL -ON WHEN TURNED BACK ON. NOTES: O LIGHTS SHALL BE SET TO BE ON FROM 7AM TO 11 PM. IF LIGHTS ACTIVATE DURING OFF HOURS BY A LIGHT SWITCH THEY SHALL TURN OFF AFTER 2 HOURS. (D LIGHTS SHALL TURN OFF AFTER 30 MINUTES OF OCCUPANCY SENSOR NOT DETECTING AN OCCUPANT. LIGHTS SHALL BE MANUAL ON VIA LIGHT SWITCH. O PHOTOSENSOR SHALL SET THE MAXIMUM LIGHT OUTPUT BASED ON NATURAL LIGHT LEVELS. DESIGN LEVEL IS BASED ON 30 FOOTCANDLES. O 1/0 MODULE SHALL BE BASED ON PRIMARY DAY LIGHTING ZONE O 1/0 MODULE SHALL BE BASED ON THE SECONDARY DAY LIGHTING ZONE O 3-WAY SWITCHING O 4-WAY SWITCHING O CONTROLLED BY SWITCH "a" IN PRO SHOP 101. O CONTROLLED BY SWITCH "b" IN PRO SHOP 101. 3 CONTROLLED BY SWITCH "a" IN RSO 110. D CONTROLLED BY SWITCH "b" IN RSO 110. 12 CONTROLLED BY SWITCH "c" IN RSO 110. 13 CONTROLLED BY SWITCH "d" IN RSO 110. 94 CONTROLLED BY SWITCH "a" IN RSO 112. 15 CONTROLLED BY SWITCH "b" IN RSO 112. 16 CONTROLLED BY SWITCH "c" IN RSO 112. CONTROLLED BY ASTRONOMICAL TIMECLOCK. ON 1-HOUR PRIOR TO SUNSET, OFF 1-HOUR AFTER SUNRISE. LEGEND: Y=YES N=NO 0 = ON/OFF D = DIMMING N/A = NOT APPLICABLE CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 info@crossengineers.com T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com 1/12/23 w Z Q O O 0 z 0 U Z 0 � = Q O c� v J J W V Z� W N 0 Lr) Z Q O0 1 �2 Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 ELECTRICAL SCHEDULES E-503 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright @ 2022 by Thomas Architecture Studio. All rights reserved. CD w N 00 0 N N 0) N 00 0 aD I NOTE: FOR LOCATIONS WHERE THERE ARE MORE THAN TWO (2) BOXES, CONTRACTOR SHALL ADJUST CENTER LINE SPACING UNIFORMLY THROUGHOUT PROJECT TO ACCOMMODATE COVER PLATE. NOTE: 1. PROVIDE MINIMUM 3/4"C(OR PLENUM R CABLE) -FIRE ALARM CONDUCTORS TO AL ALARM DEVICES. 2. PROVIDE CONTACT CLOSURE RELAYS A SIGNAL TO THE SECURITY SYSTEM TO i RELEASING OF DOORS, ETC. 3. FIRE ALARM SYSTEM SHALL BE SILENT APPROVED EQUAL. LOW AIR PRESSURE SWITCH FLOW SWITCH TAMPER SWITCH POST INDICATOR VALVE SEE — CIVIL SITE PLAN FOR LOCATION FA EXPA STEEL BUILDING STUDS, TYPICAL 3/4"C MINIMUM (POWER) POWER 5. W U 10 18" ABOVE FINISHED FLOOR, TYPICAL RECEPTACLE, TYPICAL DATA/PHONE, TYPICAL VIC MINIMUM (COMM) TO ACCESSIBLE CEILING SPACE 4" SQUARE STEEL BACKBOX, TYPICAL O ";P, 0 SCREW GUN BOX BRACKET, TYPICAL TYPICAL RECEPTACLE/DATA MOUNTING NOT TO SCALE 0 SEAL WITH TACK COAT PRIOR TO PATCHING, TYPICAL PROVIDE SLURRY JOINT SEALER. SPRINKLE WITH SAND. FIRE ALARM CONTACT CLOSURE RELAY FOR SECURITY DOOR(S) POWER DEACTIVATION. SEE ARCHITECTURAL DOOR HARDWARE SCHEDULE FOR LOCATIONS. DUCT MOUNTED SMOKE DETECTOR. PROVIDE FOR ALL HVAC EQUIPMENT RATED FOR 2000 CFM OR GREATER. SEE MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULES FOR LOCATIONS. LED CEILING MOUNTED LIGHT FOR DUCT MOUNTED SMOKE DETECTOR SMOKE DAMPERS. SEE MECHANICAL FOR LOCATIONS SMOKE DETECTOR FIRE ALARM SPEAKER/STROBE FIRE ALARM HORN/STROBE MANUAL FIRE ALARM PULL STATION FIRE DOORS. SEE ARCHITECTURAL DOOR HARDWARE SCHEDULE FOR LOCATIONS. DOOR HOLD OPENS (24VDC) AND DOOR CLOSERS (24VDC). SEE ARCHITECTURAL DOOR HARDWARE SCHEDULE FOR LOCATIONS. .,., , - , ., ., — —.1.TOR C FIRE ALARM RISER DIAGRAM -601 NO SCALE I I 3" 3" FINAL FINISHED GRADE FOR GRASS OR UNFINISHED AREAS RAKE SMOOTH 3" COMPACTED ASPHALTIC CONCRETE _ PAVEMENT. SEE CIVIL FOR 611 ADDITIONAL REQUIREMENTS o mv_ RED "TERRA TAPE" WARNING TAPE (ELEC. BURIED BELOW) (COMMUNICATIONS BURIED BELOW) NATIVE BACKFILL, CLEANED OF ORGANIC MATERIAL AND COBBLES LARGER THAN 3" IS ACCEPTABLE. COMPACT TO 95% CONDUIT(S). QUANTITY VARIES. J--- - SAND BEDDING: CLEAN, FREE FLOWING, COURSE GRADE SAND, AS DEFINED BY ASTM D 2487. COMPACT TO 95% �BCONDUIT TRENCHING E-601 NOT TO SCALE CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 Tacoma, WA 98405 Job Number: 22-082 Im info@crossengineers.com T H O M A S architecture studios 525 COLUMBIA ST. OLYMPIA, WA 98501 360.915.8775 tasolympia.com M2/23 w Z Q 0 0 z j 0 OLU LU (D ZCD O 0 CD - � J Project No: 2212 1007o CONSTRUCTION JANUARY 12, 2023 ELECTRICAL DETAILS E-601 All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. QD O n