Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Envelope Compliance Summary
Administered by: ©2024 NEEA, All rights reserved Date: Mar 15, 2024 ENVELOPE COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title El Rey Burro - 2018 WSEC For Building Department Use: Project Address 604 W. Yelm Ave Yelm, WA 98597 Applicant Name James Guerrero Applicant Phone 253-581-6000 Applicant Email james@jgarch.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type(s)Dining, Fast Food Building Cond. Floor Area 1,445 Project Scope New Building Space Conditioning Categories Fully Conditioned Project Cond. Floor Area 1,445 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Envelope Project Description Construction of a fast food restaurant. Envelope Compliance Scope and Method Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification New Building Fully Conditioned Prescriptive 14.77% / 0%None selected No alternates selected COMPLIES Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments Project Title El Rey Burro - 2018 WSEC Date Mar 15, 2024 Scope & Space Conditioning NEW BUILDING - FULLY CONDITIONED Compliance Verification COMPLIES Window-to-wall Ratio 14.77%Skylight-to-roof-ratio 0%Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Insulation entirely above deck A1.2 Roof Plan Exterior R-38 (< 0.04%)U-0.027 1,337 U-Factor Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Wood-framed and other - Commercial A1.1 Floor Plan Exterior R-21 R-0 (< 0.04%)U-0.054 1,928 Which insulation code target does wall comply with?: R-21 Cavity + Intermediate Framing U-Factor Source: U-Factor Source Description:Wall Framing Type (Standard, Inter., Advanced): Intermediate Framing Depth: 2x6 Framing Spacing: 16 Is this assembly exterior or interior?: Exterior Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab A3.2 Floor Plan At grade level R-10 F-0.54 160 Slab Insulation Method: 2 ft horizontal (no slab edge insulation)F-Factor Source: F-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Firefox https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PXN... 1 of 2 3/15/2024, 10:50 AM Vertical Fenestration Location in Documents Assembly ID Assembly Location Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) All other fenestration types A1.1 C Exterior PF < 0.2 SHGC-0.38 U-0.30 140 U-Factor & SHGC Source:U-Factor Source Description: Is this assembly exterior or interior?: Exterior All other fenestration types A1.1 D Exterior PF < 0.2 SHGC-0.51 U-0.30 16 U-Factor & SHGC Source:U-Factor Source Description: Is this assembly exterior or interior?: Exterior All other fenestration types A1.1 A Exterior PF ≥ 0.5 SHGC-0.38 U-0.30 84 U-Factor & SHGC Source: NFRC Rating U-Factor Source Description: Is this assembly exterior or interior?: Exterior All other fenestration types A1.1 B Exterior PF ≥ 0.5 SHGC-0.61 U-0.30 47 U-Factor & SHGC Source:U-Factor Source Description: Is this assembly exterior or interior?: Exterior All other fenestration types A1.1 B NO SHADING Exterior PF < 0.2 SHGC-0.38 U-0.30 47 U-Factor & SHGC Source:U-Factor Source Description: Is this assembly exterior or interior?: Exterior Firefox https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PXN... 2 of 2 3/15/2024, 10:50 AM