Loading...
Bennett, Lonnie - PVREV #1 LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE , YELM, WA 98597 All corresponding changes are notated on the plans by revision clouds. The changes outlined in Revision Details have been applied to the plans corresponding to the following customer: Revision Details: POI changed line side tap to breaker tie in MSP. Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or concerns. Construction Engineering Freedom Forever Planset Revision Letter Attn. City of Yelm (WA): 4/1/2024 Freedom Forever engineering@freedomforever.com THIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 2020 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY CITY OF YELM CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: ROOF MOUNT PHOTOVOLTAIC SYSTEM PV-1 SITE LOCATION PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B ARRAY AND STRUCTURAL TABLES PV-3 MOUNTING DETAILS PV-5 CONDUCTOR CALCULATIONS PV-5A ELECTRICAL CALCULATIONS PV-5A LOAD CALCULATION PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. PV-1 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - GREG ALBRIGHT SITE LOCATION THIS SYSTEM DESIGNED WITH: WIND SPEED: 97 WIND EXPOSURE: B SNOW LOAD: 15 JB AC INV MBE UM SITE PLAN SCALE: 2/25" = 1'-0"1 ROOF LINE PROPERTY LINE D R I V E W A Y (N) MAIN BREAKER ENCLOSURE (N) 15 FREEDOM FOREVER: FF-MP-BBB-400 (E) UTILITY METER (N) JUNCTION BOX TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 2710.6 SQ FT SINGLE MODULE AREA: 21.01937947 SQ FT TOTAL NUMBER OF MODULES: 15 TOTAL AREA OF MODULES: 315.29 SQ FT ROOF COVERAGE: 11.63% FIRE SPRINKLERS : NO PV SYSTEM 6.000 kW-DC 5.000 kW-AC (N) SOLAREDGE SE5000H-USRGM [SI1] INVERTER WITH RAPID SHUTDOWN (N) VISIBLE LOCKABLE LABELED DISCONNECT EATON DG222URB (OR EQUIVALENT) PV-2 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - THIS SYSTEM DESIGNED WITH: WIND SPEED: 97 WIND EXPOSURE: B SNOW LOAD: 15 ROOF AREA: 2710.6 SQ FT SITE PLAN LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT UTILITY METER JUNCTION BOX MAIN BREAKER ENCLOSURE AC UM JB MBE UTILITY METERUM PRA I R I E V I S T A L O O P S E GREG ALBRIGHT 8 8 ' - 1 1 " 5 4 ' - 0 " 81'-4" 92 ' - 9 " 71'-11" 60 ' - 8 " 17 ' - 1 " 6'-3" 21 ' - 2 " 5'-5" 7'-7" 3'-1 " JB AC INV MBE UM PV-2A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - ROOF PLAN SCALE: 1/8" = 1'-0"1 FIRE ACCESS PATHWAYS (N) MAIN BREAKER ENCLOSURE (N) 15 FREEDOM FOREVER: FF-MP-BBB-400 (N) SOLAREDGE SE5000H-USRGM [SI1] INVERTER (N) VISIBLE LOCKABLE LABELED DISCONNECT EATON DG222URB (OR EQUIVALENT) (N) JUNCTION BOX (E) UTILITY METER PV SYSTEM 6.000 kW-DC 5.000 kW-AC NOTES: 1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3.JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 2710.6 SQ FT ROOF PLAN WITH MODULES LAYOUT LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT UTILITY METER JUNCTION BOX MAIN BREAKER ENCLOSURE AC UM JB MBE UTILITY METERUM TOTAL ROOF AREA: 2710.6 SQ FT TOTAL ARRAY AREA: 315.29 SQ FT ARRAY COVERAGE: 11.63% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT SMART SLIDE POINT-LOAD: 28.1 LBS GREG ALBRIGHT 3'- 0 " 3'-0" 3'-0" 3 ' - 0 " 3 ' - 0 " 3'-0" 3'-0" FIRE ACCESS PATHWAYS PV-2B FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - ARRAY DETAILS ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA ROOF 1 15 25 25 168 1122.82 SQ FT 315.29 SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT ROOF DETAILS: TOTAL ROOF AREA: 2710.6 SQ FT TOTAL ARRAY AREA: 315.29 SQFT ARRAY COVERAGE: 11.63% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT SMART SLIDE POINT-LOAD: 28.1 LBS GREG ALBRIGHT ROCKIT MOUNT ROOF SURFACE SKIRT ROCKIT MOUNT ROOF MEMBRANE PV MODULE ROCKIT MOUNT ROOF MEMBRANE 2" MIN. EMBED. 2" MIN. EMBED. 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2" MIN. E M B E D . ROCKIT RAIL-LESS PV MODULE 3 " M I N . (E)2X4 TRUSS @ 24" O.C. TABLE 1 - ARRAY INSTALLATION ROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE MAX UNBRACED LENGTH(FT.) STRUCTURAL ANALYSIS RESULT PENETRATION PATTERN MAX ATTACHMENT SPACING (IN.) MAX RAIL OVERHANG(I N.) ROOF 1 25 COMP SHINGLE ECOFASTEN ROCKIT SMART SLIDE 2x4 TRUSS@ 24" O.C.8 PASS STAGGERED 72 24 1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY. 2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. 3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PV-3 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - MOUNTING DETAILS STAGGERED DETAIL For Illustration purposes only STACKED DETAIL For Illustration purposes only GREG ALBRIGHT SOLAREDGE P505 POWER OPTIMIZERS JUNCTION BOX 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #10 AWG MUST BE IN EMT CONDUIT STRING-1 15 FREEDOM FOREVER: FF-MP-BBB-400 2 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT UM(N) 200A / 2P MAIN BREAKER (TOP FED) (N) 200A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) UTILITY METER (N) 30A / 2P PV BREAKER TO SUBPANEL TO UTILITY UNDERGROUND FEED 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) 60A RATED VISIBLE LOCKABLE LABELED DISCONNECT EATON DG222URB (OR EQUIVALENT) KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) SOLAREDGE SE5000H-USRGM [SI1] INVERTER AC DC RAPID SHUTDOWN SWITCH NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 21.00A @ 240V 21.00 X 1.25 =26.25AMPS 30A BREAKER - OK SEE 705.12 OF 2020 NEC 200 X 1.20 =240 240 -200 =40A ALLOWABLE BACKFEED PV SYSTEM 6.000 kW-DC 5.000 kW-AC PV-4 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - THREE LINE DIAGRAM GREG ALBRIGHT 1 PV-5 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO OPTIMIZER 2 10 40 17.24 1 1 40.00 21.55 2 DC OPTIMIZER TO JUNCTION BOX 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER 2 10 40 15.00 1 1 40.00 18.75 4 AC INVERTER TO AC DISCONNECT 3 10 40 21.00 1 1 40.00 26.25 5 AC AC DISCONNECT TO POI 3 10 40 21.00 1 1 40.00 26.25 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. PV-5A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - ELECTRICAL CALCULATIONS GREG ALBRIGHT MATERIAL LIST: PV-6 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - QTY.PART PART #DESCRIPTION 15 MODULES PV-110-400 FREEDOM FOREVER: FF-MP-BBB-400 15 OPTIMIZERS OPT-130-505 SOLAREDGE P505 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX RAC-260-049 600VDC NEMA 3R UL LISTED JUNCTION BOX 1 MOUNTING BRACKET RAC-211-201 UNIRAC E-BOSS J-BOX MOUNTING BRACKET 2 ELECTRICAL ACCESSORIES EA-350-326 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE) 2 EQUIPMENT ACCESSORIES EA-350-327 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE) 1 INVERTERS INV-120-508 SE5000H-US [SI1] RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 MONITORING EQUIPMENT ME-180-502 SOLAREDGE CELL MODEM 1 DISCONNECTS EE-321-060 60A RATED 240VAC NEMA 3R UL LISTED 3 ELECTRICAL ACCESSORIES EA-350-113 IDEAL B-TAP 4/0-10 AWG 26 FITTINGS/ANCHORS RAC-265-034 ROCKIT SMART SLIDE 28 FOOTINGS RAC-265-004 "MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021" 26 FOOTINGS RAC-265-001 "MFG: ECO FASTEN, GF-1 FLASHING GLV BLK 8X10"", MFG SKU: 3012020" FOOTINGS RAC-265-028 "MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012" FITTINGS/ANCHORS RAC-265-031 "MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035" 15 RAILS RAC-265-018 "MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012" 52 SCREW RAC-265-035 ROCKIT SCREW #12X3 OCPD SIZES: 30A FUSES 200A BREAKER SERVICE LIST: MAIN PANEL UPGRADE EQUIPMENT & SERVICE LIST GREG ALBRIGHT NOTES: M690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY IFC 605.11.3.1(1) & 690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC NEC 690.13(B) INVERTER DC SOLAR PV DC CIRCUIT EVERY 10' ON CONDUIT AND ENCLOSURES SOLAR ELECTRIC PV PANELS 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL !WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS NEC 710.15(C) & 692.9 (C) NEC 690.15 (B) & NEC 690.33(D)(2) DO NOT DISCONNECT UNDER LOAD NEC 705.12(D) & NEC 690.59 !CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.12(D) & NEC 690.59 NEC 705.12(C) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. !WARNING ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED 24 INCH 3 480 VAC 42 INCH 12 INCH 1 INCH FLASH HAZARD BOUNDARY CAL/CM^2 FLASH HAZARD AT 18 INCHES SHOCK HAZARD WHEN COVER IS REMOVED LIMITED APPROACH RESTRICTED APPROACH - 500 V CLASS 00 GLOVES PROHIBITED APPROACH - 500 V CLASS 00 GLOVES LOCATION:14849 PRAIRIE VISTA LOOP SE,YELM, WA 98597 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 21.00A 240V!WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 690.54 NEC 705.12(B)(3)(3) NEC 706.15(C) AND NEC 110.16 !WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(E) PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT AND ENCLOSURES NEC 690.31 NEC 690.31(D)(2) NEC 690.13(B) PHOTOVOLTAIC DC DISCONNECT 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 MAXIMUM DC VOLTAGE OF PV SYSTEM ARRAY J/B NEC 690.31(G)(3) & (4) 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3)MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX DC-DC CONVERTER OUTPUT CURRENT V A A 13.5 480 15 PV-7 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - LABELS GREG ALBRIGHT 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS 15 PV MODULES VISIBLE LOCKABLE LABELED DISCONNECT CAUTION: PV-7A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL N PRAI R I E V I S T A L O O P S E POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN UTILITY METER MAIN BREAKER ENCLOSURE INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX JB PV-8 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - SOLAREDGE OPTIMIZER CHART OPTIMIZER CHART GREG ALBRIGHT 1 1-10 11-20 21-30 31-40 41-50 51-60 2 3 4 5 6 7 8 9 10 JB AC INV MBE UM PV-9 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - SAFETY PLAN GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET INCIDENT REPORTING: INJURIES - CALL INJURY HOTLINE (855) 400-7233 *If injury is life threatening, call 911 first THEN the Injury Hotline NON-INJURIES - USE MOBILE INCIDENT REPORTING (Auto, Property Damage, Near Miss) NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: NAME: _______________________________________________ ADDRESS: ___________________________________________ NEAREST HOSPITAL: NAME:_______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION: NAME: _______________________________________________ PHONE NUMBER: _____________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O BREAK AND WATER LOG THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS POLICIES INSTRUCTIONS: 1.SCAN QR LINK BELOW TO ACCESS ALL FREEDOM FOREVER SAFETY POLICIES AND PROGRAMS. JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access ·Ladders must be inspected before each use. ·Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. ·Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. ·A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). ·Additional notes: Mobile Equipment ·Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. ·Type(s) of mobile equipment (Type/Make/Model): ·Qualified operator(s): Material Handling and Storage ·Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection ·A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. ·First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. ·FPCP (name and title): ·FPU and LPD (name and title): Electrical Safety ·The Electrical Qualified Person (EQP) is required onsite to perform electrical work. ·All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. ·Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. ·EQP (name and tile): Public Protection ·The safety of the Client and Public must be maintained at all times. ·The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. ·Company, Client and Public property shall be protected from falling objects. ·Pets (including dogs) shall be secured by their owners prior to work start. ·The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. ·Crew leader responsible for communication with the client: ·Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing ·All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. ·Crew leader (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): Airborne Contaminants: ·Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) ·Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. ·If yes, list specific tasks and protection in place: Weather and Environment ·The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) ·The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. ·Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. ·Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention ·Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. ·Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. ·New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. ·Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. ·Cool Vests are encouraged for all employees at all times during periods of high heat. ·Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? ·If offsite replenish is necessary, where will you go to replenish water (location/address): ·Who will replenish the drinking water (name): Restroom facilities ·Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. ·Restroom facilities will be (circle one): Onsite - Offsite ·If Offsite, add location name and address: Incident Reporting Procedure ·Contact your Site Supervisor Name: Phone: ·Contact your Manager Name: Phone: ·Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407466 DESIGNED BY: P.P. CLIENT: LONNIE BENNETT 14849 PRAIRIE VISTA LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165449164 APN: 8186-00-02100 PHONE: (360) 789-1373 EMAIL: PRNCESS14324@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 15 X 400 = 6.000 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 15 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 15 X SOLAREDGE P505 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 4/1/2024 P.P.4/1/2024 -- -- 1 - - SAFETY PLAN GREG ALBRIGHT SCAN QR CODE TO  ACCESS REFERENCE LINK PV INSTALLATION REFERENCESFREEDOM REFERENCES BATTERY INSTALLATION REFERENCES ENPHASE SOLAREDGE TESLAINSTALL HOTLINE TESLA Storage Systems NON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage Systems Misc. Quick Guide FOR INSTALLATION REFERENCE ONLY V1.4 Pe r f o r m a n c e F i g u r e s i n % MECHANICAL LOADING MODULE SPECIFICATIONS 17 2 2 ± 2 17 2 2 . 0 M M 13 1 6 . 0 M M 22 7 . 2 M M TEMPERATURE RATINGS PACKAGING INFORMATION MECHANICAL CHARACTERISTICS OPERATIONS CHARACTERISTICS 35 [ 1 . 3 8 ] UL 61730 | UL 61215 | ISO 9001 | ISO 14001 ELECTRICAL CHARACTERISTICS for L. Matthew Snyder, Certification Manager Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety solaredge.com PO W E R O P T I M I Z E R Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370 (for higher- power 60 and 72- cell modules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell modules) P405 (for high- voltage modules) P485 (for high- voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power (1)320 350 370 400 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 125(2)83(2)Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc)11 11.02 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER ) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF ) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 / 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm /in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52 0.16 or 0.9 /0.52 or 2.95 (5)0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range (6)-40 to +85 / -40 to +185 Ü&/Ü) Protection Rating IP68 /7\SH 3 Relative Humidity 0-100 %  Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed  NEC 2017 requires max input voltage be not more than 80V  For other connector types please contact SolarEdge  For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals  Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx  For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using aSolarEdge Inverter (7)(8) Single Phase HD-Wave Single phase Three Phase for208V grid Three Phase for277/480V grid Minimum String Length (Power Optimizers) P320, P340, P370, P400, P401 8 10 18 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50(9) Maximum Power per String 5700 (6000 with SE7600-US - SE11400- US) 5250 6000(10)12750(11)W Parallel Strings of 'L੔HUHQW Lengths or Orientations Yes  )RUGHWDLOHGVWULQJVL]LQJLQIRUPDWLRQUHIHUWRKWWSZZZVRODUHGJHFRPVLWHVGHIDXOWILOHVVWULQJBVL]LQJBQDSGI  ,WLVQRWDOORZHGWRPL[333ZLWK33333LQRQHVWULQJ  $VWULQJZLWKPRUHWKDQRSWLPL]HUVGRHVQRWPHHW1(&UDSLGVKXWGRZQUHTXLUHPHQWVVDIHW\YROWDJHZLOOEHDERYHWKH9UHTXLUHPHQW  )RU9JULGLWLVDOORZHGWRLQVWDOOXSWR:SHUVWULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKVWULQJLV:  )RU9JULGLWLVDOORZHGWRLQVWDOOXSWR:SHUVWULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKVWULQJLV: © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date:/2021 DS-000044-1.-NA. Subject to change without notice. 40 solaredge.com SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014-2023 per articles 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Small, lightweight, and easy to install both outdoors or indoors Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) 12-25 YEAR WARRANTY SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT Rated AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA ACOutput Voltage Min.-Nom.-Max. (211 - 240 - 264) Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) ---Vac ACFrequency (Nominal)59.3 - 60 - 60.5 (1)Hz Maximum Continuous Output Current @240V 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V 16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 Vdc Maximum Input Current @240V(2)10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1)For other regional settings please contact SolarEdge support. (2)A higher current source may be used; the inverter will limit its input current to the values stated. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: June 19, 2023 DS-000153-NAM. Subject to change without notice. SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), wireless SolarEdge Home Network (optional)(3), Wi-Fi (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(4) Consumption Metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown -NEC 2014-2023 per articles 690.11 and 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14 (HI), CSA C22.3 No. 9 Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14 6 AWG 1'' Maximum / 14 4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1 2 strings / 14 6 AWG 1'' Maximum / 1 3 strings / 14 6 AWG Dimensions with Safety Switch (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(5) in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 44.9 / 20.4(5)lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(6) Protection Rating NEMA 4X (Inverter with Safety Switch) (3)For more information, refer to the SolarEdge Home Network datasheet (4)Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BEI4. For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box. (5) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4 will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (6)-rating information refer to the Temperature De-rating Technical Note for North America. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills. Product specifications Eaton DG222URB Catalog Number: DG222URB Eaton General duty non-fusible safety switch, single-throw, 60 A, NEMA 3R, Rainproof, Painted galvanized steel, Two-pole, Two-wire, 240 V General specifications Eaton general duty non-fusible safety switch DG222URB 782113144238 7.38 in 14.38 in 8.69 in 9 lb Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. UL Listed WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Product Name Catalog Number UPC Product Length/Depth Product Height Product Width Product Weight Warranty Certifications Catalog Notes Eaton Corporation plc Eaton House 30 Pembroke Road Dublin 4, Ireland Eaton.com © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are property of their respective owners.Eaton.com/socialmedia Product specifications General duty safety switch Painted galvanized steel Non-fusible, single-throw Non-fusible 2 NEMA 3R 240V 60A Two-pole Resources Eaton's Volume 2—Commercial Distribution Double Up on Safety Switching Devices Flex Center Eaton Specification Sheet - DG222URB Selling Policy 25-000 - Distribution and Control Products and Services Product Category Enclosure material Type Fuse configuration Number of wires Enclosure Voltage rating Amperage Rating Number Of Poles Catalogs Multimedia Specifications and datasheets Warranty guides INSULATION -PIERCING TAP CONNECTORS CONECTORES DE DERIVACION QUE PERFORAN EL AISLAMIENTO Installation Instructions: Improperly installed electrical wiring can be dangerous Aand cause electrical fires. The connector chosen must be sized to the wires being used. Consult local building code before doing any electrical work. For assistance, refer to an instructional book or consult a qualified electrician. Contact with electricity can cause serious injury or death. Use on insulated cable only. [RHH, RHW(-2), THHN, THHW, THW, THWN, USE, XHHW(-2). Consult factory for other insulation types]. If the installation is to be made on an energized run, the tap conductor must be under no load and must not be grounded. Use electrically insulated gloves. De -energize the run cable if there are any questions of these conditions being met. 1. Determine the direction for the tap conductor to exit and discard one end cap. See figure 1. 2. Position the main (or feeder) side of the connector around the run cable and tighten the bolt finger tight. See figure 2. If required, loosen the bolt slightly to allow the connector to open completely. DISASSEMBLY NOT RECOMMENDED. The plastic 'Turbo" spacer holds the connector open which eases installation and ensures proper connections. 3. Cut the end of the tap cable squarely. DO NOT STRIP CABLE INSULATION. 4. Insert the tap cable into the tap side of the connector until it is seated in the remaining end cap. See figure 3. 5. Continue tightening the torque regulating bolt with a standard box or socket wrench until the torque regulating piece breaks away. If the connector has two (2) assembly bolts, alternately tighten until the hexagonal torque devices break away. See figures 4a & 4b. Note that the plastic "turbo" spacer on the side will also break. To make the installation even easier and to relieve torque from the cables, a second wrench can be used on the hexagonal piece on the bottom of the connector. DO NOT use gripping type pliers, pipe, open ended or adjustable wrenches as these may damage the hexagonal torque regulating device. A torque wrench is not required. MAKE SURE ONLY THE TOP HEXAGONAL TORQUE DEVICE OF THE BOLT HEAD IS USED FOR ASSEMBLY. THE SECOND HEX PIECE [CLOSER TO THE BODY OF THE CONNECTOR] IS USED FOR DISASSEMBLY. Note: The torque regulating bolt ensures the correct torque is applied to the conductors without using a torque wrench. Important information such as run and tap ranges, voltage ratings and material/temperature ratings is marked on the connector. figure 1 @ 0 Before After correct Torque Torque Reached, Applied One Hex Piece Breaks -Away figure 4a figure 4b UListed L 486B Pressure Cable Connectors File No. E-5238 Suitable for use on the line side of the service equipment. Instalacion Instrucciones: Los cables electricos mal instalados pueden ser peligrosos y provocar incendios. El conector escogido debe ser de un tamano adecuado para los cables que se utilicen. Consulte los c6digos de construccion locales antes de efectuar trabajos electricos. Si necesita ayuda, consulte un libro de instrucciones o consulte con un electricista capacitado. Use solo en cable aislado. [RHH, RHW(-2), THHN, THHW, THW, THWN, USE, XHHW(-2). Consulte con la fabrica para obtener informacion sobre otros tipos de aislamiento]. Si se va a hacer la instalacion sobre un cable con corriente el conductor derivado debe estar libre de carga y no debe estar aterado. Use guantes con aislamiento electrico. Quite le la corriente al cable del cual se hace la derivacion si no se pueden cumplir estas condiciones. El contacto con electricidad puede producir lesiones graves o mortales. 1. Determine la direccion en la que el conductor derivado saldra y deseche la tapa terminal sobrante. Vea la ilustracidn 1. 2. Coloque el lado principal (o de alimentacion) del conector alrededor del cual se hace la derivacion y apriete firmemente el dedo del perno. Vea la ilustraci6n 2. Si hace falta, afloje el perno ligeramente para permitir que el conector se abra completamente. NO ES RECOMENDABLE DESARMAR EL CONECTOR. El espaciador 'Turbo" de plastico mantiene al conector abierto, Io cual facilita la instalacion y asegura que las conexiones se hagan correctamente. 3. Corte el extremo del cable de derivacion perpendicularmente a su eje. NO PELE EL AISLAMIENTO DEL CABLE. 4. Inserte el cable de derivacion en el lado de derivacion del conector hasta que tope contra la tapa terminal que queda. Vea la ilustraci6n 3. 5. Continue apretando este perno que regula la torsion con una Ilave estandar o de cubo hasta que la pieza que regula la torsion se parta y se separe. Si el conector tiene dos (2) pernos de ensamblaje, apriotelos alternativamente hasta que el dispositivo de regulacion de torcib se parta. Vea la ilustraci6n 4a y 4b. Observe que el espaciador "turbo" de plastico en el costado tambien se fracturara. Para hacer esta instalacion a6n mas facil y para aliviar la torsion de los cables, se puede usar una. segunda Ilave sobre la pieza hexagonal al fondo del conector. NO USE alicates de presi6n, (laves de turbo, (laves comunes o ajustables ya que estas pueden danar el dispositivo hexagonal que regula la torsion. No se requiere una Ilave de torsion. ASEGORESE DUE SE USE, PARA EL ENSAMBLADO, SOLO EL DISPOSITIVO SUPERIOR DE REGULAC16N DE TORSION DE LA CABEZA DEL PERNO. LA SEGUNDA PIEZA HEXAGONAL (LA MAS CERCANA AL CUERPO DEL CONECTOR) SE USA SOLO PARA DESARMAR EL CONECTOR. Nota: El perno regulador de torsion garantiza la aplicacion de la torsion correcta a los conductores sin usar una Ilave de torsion. La informacion importante de longitud de cable pelado y de toma, las clasificaciones de materiales y temperatura esta marcada en el conector. B-TAP° INSULATION PIERCING TAP CONNECTORS TORQUE AND CURRENT RATINGS (Solid and/or Stranded) NOMINAL TAP CURRENT RATIING CATALOG# MAIN TAP TORQUE (IN AMPS)* BTC2/0-14 2/0-4 10-14+ 80 IN. LBS. 40 BTC1/0-10 1/0-8 2-10- 80 IN. LBS. 130 BTC4/0-10 4/0-3 2-10- 125 IN. LBS. 130 BTC4/0-6 4/0-2 1/0-6 160 IN. LBS. 170 BTC4/0-2 4/0-2 4/0-2 160 IN. LBS. 260 BTC250-6 250-4 4/0-6 160 IN. LBS. 260 BTC250-4 250-1 3/0-4 160 IN. LBS. 225 BTC250-2 250-1/0 4/0-2 160 IN. LBS. 260 BTC350-1/0 350-1/0 350-1/0 330 IN. LBS. 350 BTC500-4 500-2/0 4/0-4 330 IN. LBS. 260 BTC500-1/0 500-4/0 350-1/0 330 IN. LBS. 350 BTC500-14 750-3/0 10-14... 80 IN. LBS. 40 BTC750-250 750-250 500-250 3301N.LBS. 430 +10-14 Cu SOLID/STRANDED; 10-12 Al SOLID/STRANDED ++2-10 Cu SOLID/STRANDED; 2-10 Al STRANDED +++2-10 Cu SOLID/STRANDED; 2-8 Al STRANDED ++++10-14 Cu SOLID/STRANDED;10-12 Al STRANDED Full line is 600V dual-rated,194°F(90°C) " Based on NEC Table 310-161996 (Not more than 3 insulated conductors in a raceway at ambient temperature of 30° C) for the largest tap wire size. WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. AADVERTENCIA: Cancer y Dana Reproductivo - www.P65Warninas.ca.aov. One year limited warranty. See idealind.com for more information. Garantra limitada de un ano. Visite www.idealind.com para obtener detalles de la garantfa. 1800 S. Prairie Drive Sycamore, IL, U.S.A. 800-435-0705 • www.idealind.com ND 9053-2 1839420 IDEAL INDUSTRIES, INC. 1375 Park Avenue s 6017 .com ALL IDEAL Customers 2/9/23 Subject: The Buchanan B-TAP® splice/tap connectors meet the 2020 NEC article 230.46 requirement for line side applications The Buchanan B-TAP® brand of insulation piercing connectors which correspond to part numbers beginning with BTC meet the requirements of article 230.46 of the 2020 NEC. These products have already been tested to the newer requirements. The installation instructions are in the process of being updated to show the required notation: suitable for use on the line side of the service equipment . This change will take a few weeks to get into our production. In addition, the marking SR will be added to the product. That addition is in process and will take a few months to complete. This notice will provide confirmation to the inspectors that B-TAP® products meet the requirements of the 2020 and 2023 NEC article 230.46 Spliced and Tapped Conductors . Sushil Keswani Director of Engineering IDEAL Industries, Inc., UL Product W OUL Solutions ZMVV.E5238 - Wire Connectors and Soldering Lugs Note: We are enhancing our systems and you may notice duplicate entries/missing/outdated data. During this interim period, please contact our Customer Service at https://www.ul.com/about/locations. Wire Connectors and Soldering Lugs IDEAL INDUSTRIES INC E5238 1375 Park Ave SYCAMORE, IL 60178 United States View model for additional information Insulated butt splice crimp type connectors, Model(s): BVS1, BVS2, BVSS Insulated flange spade type crimp cconnectors, Model(s): SV5-3.7, SVL5-4, SVL5-6 Insulated flange spade type crimp connectors, Model(s): FSNYD1-3.7, FSNYD1-4, FSNYD1-5, FSNYD2-3.7, FSNYD2-4, FSNYD2-5, FSNYD5-3.7, FSNYD5-4, FSNYD5-5 Insulated hook type crimp connectors, Model(s): HNYD1-3.7, HNYD1-4, HNYD1-5, HNYD2-3.7, HNYD2-4, HNYD2-5, HNYD5-3.7, HNYD5-4, HNYD5-5, HVY1-3.7, HVY1-4, HVY1-5, HVY2-4, HVY2-5, HVY5-3.7, HVY5-4, HVY5-5 Insulated locking spade crimp connectors, Model(s): LSNYD1-3.7, LSNYD2-3.7, LSNYD5-3.7, LSNYD5-4, LSNYD5-5, LSNYDL1-4, LSNYDL1-5, LSNYDL2-4, LSNYDL2-5 Insulated multiple stud ring type crimp connectors, Model(s): MSRNYD1-3753, MSRNYD2-3753, MSRNYD5-3753 Insulated parallel connectors, Model(s): PVT1, PVT14, PVT2, PVT22, PVTS, PVT8 Insulated pin type connectors, Model(s): PTNYD1-121 PTNYD2-12, PTNYD5-13 Insulated ring type crimp connectors, Model(s): RNYB14-11, RNYB22-11, RNYD1-10, RNYD1-3.2, RNYD1-5, RNYD1-6, RNYD1-8, RNYD2-10, RNYD2-2, RNYD2-3.2, RNYD2-6, RNYD2-8, RNYD5-10, RNYDS-12, RNYD5-3.2, RNYD5-3.7, RNYD5-5, RNYD5-6, RNYD5-8, RNYDL1-3.7, RNYDL1-4, RNYDL2-3.7, RNYDL2-4, RNYDL5-3.7, RNYDL5-4, RNYDM2-3.7, RNYDS1-3.7, RNYDS1-41 RNYDS2-4, RNYDS2- 5, RNYDSS-4, RV1-3.2, RV1-5, RV1-6, RV2-3.2, RV5-10, RV5-3.7, RV5-5, RV5-6, RV5-8, RVL1-4, RVL2-4, RVLS-4, RVM1-3.7, RVM2-3.7, RVY1-3.2 Insulated spade type crimp connectors, Model(s): SNYD1-3.2, SNYD5-3.7, SNYD5-5, SNYDL1-3.7, SNYDL1-4, SNYDL2-3.7, SNYDL2- 4, SNYDL2-5, SNYDL5-4, SNYDLL1-3.7, SNYDLL2-3.7, SNYDM1-4, SNYDM2-4, SNYDS1-5, SNYDS2-5, SVL1-3.7, SVL1-5, SVL2-3.7, SVL2 5, SVM 1-4, SVM2-4, SVY1-3.2, SVY2-3.2, SVY5-3.7, SVY5-5, SVYL1-3.7, SVYL1-4, SVYL2-3.7, SVYL2-4, SVYL2-5, SVYL5-4, SVYLL1-3.7, SVYLL2-3.7, SVYM1-4, SVYM2-4, SVYS1-5, SVYS2-5, SVYS5-4 Y U Insulated splice connectors, Model(s): PB1-, P132-, P135- v U_ LL Insulating caps or covers, for use on manufacturers splice caps, for 2006-5, 2008-5 connectors, Model(s): 2007 Listed pressure cable connectors, Model(s): BHT1, BHT2, BHTS, BN1, BN2, BNS, BNT1-16, BNT14, BNT2-16, BNT22, BNT5-20, BNTB, BNYDF1, BNYDF2, BNYDFS, BNYT1, BNYT2, BNYTS, BV1, BV2 BV5, BVT14, BVT22, BVT8 Listed pressure ring terminal connectors, Model(s): RNYB14-8, RNYB8-11, RNYBL22-5, RNYBL22-6 Listed splicing wire connectors, Model(s): L12, L13, L15 Non -insulated flange spade crimp connectors, Model(s): FSN1-3.7, FSN1-4, FSN1-5, FSN2-3.7, FSN2-41 FSN2-5, FSN5-3.7, FSN5-4, FSN5-5, FSN131-3.7, FSNB1-4, FSN131-5, FSNB2-3.7, FSNB2-4, FSN132-5, FSNB5-3.7, FSN135-4, FSNB5-5, FSNL1-3.7, FSNL2-5 Non -insulated hook crimp connectors, Model(s): HN1-4, HN1-5, HN2-3.7, HN2-4, HN2-5, HN5-3.7, HN5-4, HN5-5 Non -insulated locking type crimp connectors, Model(s): LSN1-3.7, LSN2-3.7, LSN5-3.7, LSN5-4, LSN5-5, LSN5-6, LSNL1-4, LSNL1-5, LSNL2-5 Non -insulated multiple stud ring type crimp connectors, Model(s): MSRNB1-3753 Non -insulated parallel crimp connectors, Model(s): PNT 1, PNT 14, PNT 2, PNT 22, PNT 5, PNT 8, PNT1, PNT2, PNTS Non -insulated pin type crimp connectors, Model(s): PTN1-12, PTN2-12, PTN5-13 Non -insulated ring type crimp connector, Model(s): RNB1-10, RN131-3.2, RNB14-11, RNB14-12, RN1314-16, RNB1-6, RN131-8, RNB2- 10, RNB2-2, RN132-6, RN135-12, RNB8-12, RNBL1-4 Non -insulated ring type crimp connectors, Model(s): RNB1-3.2, RNB14-10, RNB14-5, RNB14-8, RN131-5, RN132-10, RNB22-10, RNB22-12, RNB22-8, RNB2-3.2, RNB2-8, RNB5-10, RNB5-3.2, RNB5-3.7, RNB5-3.7, RNB5-51 RNB5-6, RNB5-8, RNB8-101 RNB8-11, RNB8-16, RNB8-8, RNBL1-3.7, RNBL22-5, RNBL22-6, RNBL2-3.7, RNBL2-5, RNBL38-10, RNBL5-3.7, RNBL5-4, RNBM1-3.7, RNBM1-3.7, RNBM2-3.7, RNBM2-3.7, RNBM8-51 RNBS1-4, RNBS14-5, RNBS2-4, RNBS2-5, RNBS5-4, RNBS8-6 Non -insulated spade type crimp connectors, Model(s): SN1-3.2, SN2-3.2, SN5-3.7, SN5-5, SN131-3.2, SN135-3.7, SN135-5, SNBL1-3.7, SNBL1-4, SNBL2-4, SNBL2-5, SNBL5-4, SNBL5-6, SNBLL1-3.7, SNBLL2-3.7, SNBM1-4, SNBS1-5, SNBS5-4, SNL1-3.7, SNL1-4, SNL2-3.7, SNL2-4, SNL2-5, SNLL1-3.7, SNLL2-3.7, SNM1-4, SNM2-4, SNS1-5, SNS2-5, SNS5-4 Pressure cable connectors, Model(s): KB - 1000, KB - 2/0, KB - 350, KB - 4/0, KB - 500, KB - 800, KS - 1000, KS - 2/0, KS - 350, KS - 4/0, KS - 500, KS - 800 Pressure terminal connectors, Model(s): FSVY1-3.7, FSVY1-4, FSVY1-5, FSVY2-3.7, FSVY2-4, FSVY2-5, FSVY5-3.7, FSVY5-4, FSVY5-5, K-56551 K-5656, LSV1-3.7, LSV2-3.7, LSV5-4, LSV5-5, LSV5-6, LSVL2-4, LSVS1-4, LSVS1-5, LSVS2-5, LSVY1-3.7, LSVY2-3.7, LSVY5-3.7, LSVY5-4, LSVY5-5, LSVY5-6, LSVYL1-4, LSVYL1-5, LSVYL2-4, LSVYL2-5, MSRNB2-3753, MSRVYl-3753, MSRVY2-3753, MSRVY5-3753, PTVY1-12, PTVY2-12, PTVY5-131 RVY1-101 RVY1-5, RVY1-6, RVY1-8, RVY2-10, RVY2-2, RVY2-3.2, RVY2-6, RVY2-8, RVY5-10, RVY5-12, RVY5-3.2, RVY5-3.7, RVY5-5, RVY5-6, RVY5-8, RVYL1-3.7, RVYL1-4, RVYL2-3.7, RVYL2-4, RVYL2-5, RVYL5-3.7, RVYL5-4, RVYM2-3.7, RVYS1-3.7, RVYS1-4, RVYS2-3.7, RVYS2-4, RVYS2-5, RVYS5-4, SNBM2-4, SNYD2-3.2, TLK16-6, TLK25-10 Pressure Terminal Connectors, Model(s): RNYB14-10, RNYB14-12, RNYB14-5, RNY1322-12, RNYB22-8, RNY138-10, RNY138-12, RNY138- 8, RNYBM8-5, RNYBS14-6 Slicing wire connectors, Model(s): OK-2 (Pkg. cat No. 84), OK-3 (Pkg. cat No. 85), OK-4 (Pkg. cat No. 86) OK-5 (Pkg. cat No. 87), OK- 6W (Pkck . cat No. 88), OK-8 (Pkck . cat No. 90), OK-8W (NA). Splicing wire connectors, Model(s): 12, 13, 14 14-6, 15, 199, 1995, 200, 2002, 2006-5, 2008-5, 2011-5, 22-10, 22-12, 29, 299, 2995, 30 300, 32, 33, 34, 340, 36, 37, 38, 39, 399, 400 400AL, 42, 50 615069, 66, 70 800, AS-1/0, AS-2, AS-2/0, AS-350, AS-4, AS-4/0, AS-500, AS-6, B1 B2, B4, BT-2, BTC 1/0-10, BTC 1/0-14, BTC 2/0-14, BTC 250-4, BTC 350-1/0, BTC 4/0-10, BTC 4/0-2, BTC 4/0-6, BTC 500-1/0, BT 500-14, BTC 500-4, BTC1/0-10, BTC2/0-14, BTC250-4, BTC350-1/0, BTC4/0-10, BTC4/0-2, BTC4/0-6, BTC500-1/0, BTC500-14, BTC500-4, BV1, BV1, BV2, BV2 BV5, BVS, C=3 C=4, C=5 Kam, K1000, K2 Kam, K250, K3 Kam, K350, K4 K500, K6 K750, K8, KS10, R1, S1/0, 52, LZ S2/0, 5250, S3, S3L 5350, S4, 5500, S6, TR 1, TR 2, W1, W2, W4, WT1, WT2, WT3, WT4, WT6 WTW51, WTW52, WTW53, WTW54 Insulating caps or covers, for use on manufacturers splice caps, for 2011-5 connector, Model(s): 2014 Splicing Wire Connectors, Model(s): BNT11 BNT2 Splicing Wire Connectors% Model(s): 46-404, 46-405 Splicinig wire connectors, Model(s): H-1566, H-1567, H-1570, H-1571, H-1572, H-1591, H-1592, H-1594 Terminal connectors, Model(s): 10, 11 22, 250, 300, 341, 342, 410 with insulating cap No. 415, 411 with insulating cap No. 417.412 with insulating cap No. 417, 451 452, 454 48, 49 49 Black, 53-B, 59B, 600, 71 B#, 72B#, 73B#, 73B+, 74B, 76B 76B+, 78B+, 82 K-5504 LSNL2-4, MM=3, PV3-750, PV3-750, PV3-750, PV4-750, PV4-750, PV4-750, RNBL2-4. RNBS14-6, RNBS38-6, RNBS38-8, RNYB22-10, RNYBS8-6, RV2-6, RVL2-5, SV5-5, WT1, WT2 WT3 WT4 WT41, WT51, WT52. WT53. WT54, WT6 Terminal Connectors, Model(s): RNB22-11 Wire Connectors, Model(s): 69 653 Wire Connectors and Soldering Lugs, Model(s): L22 L23 L25 PS10, PS12, PS2, PS3, P54 PS4S, P55 PS6 PS8 # - The equipment (71 B, 72B and 73B) were also evaluated to the requirements of UL 2043 and are suitable for use in air handling spaces. * - May be followed by suffix B, J, T or X. NOTE - All models may be provided with or without prefix " V" or suffix "MP" or "V" and prefix "BP". All models may be followed by suffixes BT, UB or OF with or without a two or four digit number, with or without suffixes B, LP, NP, PF, PH, SP and/or T. Die Series terminals may be followed by Suffixes UI, UT, UF, US, or UB, with or without a two to four digit number, with or without Suffix T or B, followed by Suffixes SP, LP, NP, PF, or and/or NM, by PH or BE, with or without Suffixes NT, BS, and /or G. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service. Always look for the Mark on the product. UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " ©2023 UL LLC." RaCKIT INTRODUCING ROCKIT SMART SLIDE! Introducing EcoFasten's patent pending Rocklt Smart Slide, our simple solution for quickly installing the popular Rocklt rail -less racking system to composition shingle roofs. Features & Benefits • Eliminates the need to pry up shingle courses and install a metal flashing • Multiple opportunities to find the rafter • No need for additional material when architectural shingles are not level • Longer 6.75" slide avoids overlaps in shingle courses • Integrated flashing utilizes UltraGrip TechnologyTM to create a watertight seal Required Components: 2011024 RI SMART SLIDE BLK 6.75" 2011025 RI SMART SCRW #12X3" W/BW D���444 D.IVIS/p4, APp�O.,,* V V C FL#39871 G ? D ND d �'s STATE OF DDvvvaa ROCKIT SMART SLIDE Integrated UltraGrip TechnologyTM Pre -installed sealing pads are compatible with all composition shingle roofs. The compression achieved when fastened to the roof creates a super strong watertight seal. In most cases, the slide can be mounted to the deck without the need for sealant. A layer of flexible foam provides cushioning, which allows the waterproofing sealant to embed deep into the granules of the shingle as well as to flexibly conform over the steps found on architectural -style shingles. Testing & Documentation LIDE • UL441 Rain Report • TAS 100 (A)-95 Wind and Wind Driven Rain Resistance • Mechanical Load Test/Structural Capacity Certification • Florida Product Approval • Rocklt Installation Manual • Rocklt CutSheets VI EcoFQstena 4141 W. VAN BUREN ST, SUITE 2, PHOENIX Az 85009 An Esdec Solar Group Company 1- 8 7 7- 8 5 9- 3 9 4 7 1 INFO @ E C O F A S T E N S O L A R. C OM          ;          5,60$576/,'(%/.  52&.,7)/$6+/(666/,'($66(0%/< $'+(6,9(5(/($6(/,1(5 ,7(012'(6&5,37,21 52&.,760$576/,'($66(0%/< 3$57180%(5 '(6&5,37,21 5,60$576/,'(%/. 0$7(5,$/$/80,180(3'0$'+(6,9(75($7('3$3(5 ),1,6+%/$&.5HY&6 1 .31 7.8 2.87 72.8 3.00 76.2 .55 14.0 .42 10.5 RI SMART SCREW #12X3" W/BW PART NUMBER DESCRIPTION 2011025 RI SMART SCREW #12X3" W/BW ITEM NO.DESCRIPTION 1 SELF TAPPING SCREW #12 WITH SEALING WASHER ASSEMBLY MATERIAL STAINLESS STEEL, EPDM RUBBER FINISH MILL, BLACK Rev: CS-2