MMC01 Civil Improvement PlansFI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M CO V E R NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C1 1 7 VICINITY MAP NTS 1.IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLETE ALL WORK AND TO DISPOSE OF ALL DEMOLITION DEBRIS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS. PRIOR TO ANY WORK CONTRACTOR SHALL COMPLETE ALL TESTING FOR HAZARDOUS MATERIALS AND SHALL ABATE ALL HAZARDOUS MATERIALS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS. 2. CONTRACTOR SHALL OBTAIN AND FULFILL THE REQUIREMENTS OF ANY PERMITS REQUIRED FOR ANY PROPOSED DEMOLITION ACTIVITY. 3. CONTRACTOR SHALL COORDINATE WITH AND RECEIVE APPROVAL FROM ANY PUBLIC OR PRIVATE UTILITIES AS REQUIRED FOR ABANDONMENT OF UTILITY SERVICES. CONTRACTOR SHALL APPLY FOR AND COORDINATE ANY WORK THAT MUST BE COMPLETED BY THE UTILITY PURVEYOR. CONTRACTOR SHALL ENSURE THAT ALL UTILITIES TO BE MODIFIED OR REMOVED ARE SHUT OFF PRIOR TO DEMOLITION OR CONSTRUCTION ACTIVITY. 4. PRIOR TO ANY DEMOLITION OR REMOVAL/MODIFICATION OF EXISTING UNDERGROUND UTILITY SERVICES, CONTRACTOR SHALL PERFORM BOTH A PRIVATE AND PUBLIC UTILITY LOCATE TO IDENTIFY THE HORIZONTAL AND VERTICAL LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES. 5. CONTRACTOR IS RESPONSIBLE FOR PROTECTION AND PRESERVATION OF ANY EXISTING FEATURES TO REMAIN. 6. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND DISPOSAL OF ALL EXISTING FEATURES THAT CONFLICT WITH PROPOSED FEATURES. 7. APPROVAL OF THIS SWPPP DOES NOT CONSTITUTE AN APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (E.G., SIZE AND LOCATION OF ROADS, PIPES, RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES, ETC.) 8. THE IMPLEMENTATION OF THIS SWPPP AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND APPROVED AND VEGETATION/LANDSCAPING IS ESTABLISHED. 9. DURING THE CONSTRUCTION PERIOD, NO UNAUTHORIZED DISTURBANCE BEYOND THE PROPERTY BOUNDARY SHALL BE PERMITTED. 10.THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING AND GRADING ACTIVITIES, AND IN SUCH A MANNER AS TO INSURE THAT SEDIMENT AND SEDIMENT LADEN WATER DO NOT ENTER THE DRAINAGE SYSTEM, ROADWAYS, OR VIOLATE APPLICABLE WATER STANDARDS. 11.THE ESC FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND TO ENSURE THAT SEDIMENT AND SEDIMENT-LADEN WATER DO NOT LEAVE THE SITE. 12.THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/CONTRACTOR AND MAINTAINED AS NECESSARY TO ENSURE THEIR CONTINUED FUNCTIONING. 13.THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN THE 48 HOURS FOLLOWING A MAJOR STORM EVENT. 14.AT NO TIME SHALL MORE THAN 1 FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A TRAPPED CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT LADEN WATER INTO THE DOWNSTREAM SYSTEM. 15.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT. 1. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR BEING FAMILIAR WITH THE PROVISIONS AND REQUIREMENTS CONTAINED IN JURISDICTIONAL STANDARD SPECIFICATIONS. THE CONTRACTOR SHALL HAVE A COPY AVAILABLE AT THE JOB SITE AT ALL TIMES. 2. THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS DEPARTMENT AT LEAST 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 3. THE CONTRACTOR SHALL NOTIFY ALL PUBLIC OR PRIVATE UTILITY COMPANIES 48 HOURS PRIOR TO COMMENCEMENT OF WORK ADJACENT TO EXISTING UTILITY LINES UNLESS AN ENCROACHMENT PERMIT SPECIFIES OTHERWISE. 4. THE CONTRACTOR SHALL PROVIDE EMERGENCY TELEPHONE NUMBERS TO THE POLICE, FIRE, AND PUBLIC WORKS DEPARTMENTS AND KEEP THEM INFORMED DAILY REGARDING STREETS UNDER CONSTRUCTION AND DETOURS. DETOURS SHALL NOT BE PERMITTED UNLESS APPROVED IN WRITING BY THE PUBLIC WORKS DIRECTOR. 5. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN SUFFICIENT BARRICADES TO PROVIDE FOR THE SAFETY OF THE GENERAL PUBLIC TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 6. ALL MATERIALS SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED. 7. THE CONTRACTOR SHALL CONFORM TO EXISTING STREETS, SURROUNDING LANDSCAPE AND OTHER IMPROVEMENTS WITH A SMOOTH TRANSITION IN PAVING, CURBS, GUTTERS, SIDEWALKS, GRADING, ETC., AND AVOID ANY ABRUPT OR APPARENT CHANGES IN GRADES OR CROSS SLOPES, LOW SPOTS OR HAZARDOUS CONDITIONS. 8. THE CONTRACTOR SHALL COORDINATE ALL NECESSARY UTILITY RELOCATIONS, IF REQUIRED, WITH THE APPROPRIATE UTILITY COMPANIES. 9. THE CONTRACTOR SHALL CONDUCT ALL GRADING OPERATIONS IN SUCH A MANNER AS TO PRECLUDE WIND BLOWN DIRT AND DUST AND RELATED DAMAGE TO NEIGHBORING PROPERTIES. SUFFICIENT WATERING TO CONTROL DUST IS REQUIRED AT ALL TIMES. THE CONTRACTOR SHALL ASSUME ALL LIABILITY FOR CLAIMS RELATED TO WIND BLOWN MATERIAL. IF THE DUST CONTROL IS INADEQUATE AS DETERMINED BY THE PUBLIC WORKS DIRECTOR OR HIS DESIGNATED REPRESENTATIVE, THE CONSTRUCTION WORK SHALL BE TERMINATED UNTIL SUCH CORRECTIVE MEASURES ARE TAKEN. 10.THE CONTRACTOR SHALL NOTIFY THE APPROPRIATE AGENCIES AND DEPARTMENTS FOR ALL REQUIRED INSPECTIONS PRIOR TO PLACING ANY UTILITIES INTO SERVICE. 11.THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. 12.CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE, THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 13.ALL DETAILS PROVIDED IN THESE PLANS SHALL BE APPLIED TO ALL APPLICABLE PROPOSED CONSTRUCTION, REGARDLESS OF WHETHER OR NOT SPECIFIC REFERENCES TO APPLICABLE DETAILS ARE MADE. 14.POST CONSTRUCTION SOIL QUALITY AND DEPTH BMP DETAIL 1/C6 SHALL BE APPLIED TO ALL DISTURBED PERVIOUS AREAS. 15.DO NOT COMPACT THE BOTTOM OF THE INFILTRATION GALLERY DURING EXCAVATION EROSION CONTROL NOTES THE WORK ON THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF YELM STANDARDS, AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, 2022 WASHINGTON STATE DEPARTMENT OF TRANSPORTATION (WSDOT) (HEREAFTER "STANDARD SPECIFICATIONS") ALSO INCORPORATED INTO THESE CONTRACT DOCUMENTS BY REFERENCE ARE: A. CITY OF YELM DEVELOPMENT GUIDELINES, CURRENT EDITION B. WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON, 2019 EDITION ("DRAINAGE MANUAL") C. THE INTERNATIONAL BUILDING CODE (IBC) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC), CURRENT EDITIONS, WITH CITY AMENDMENTS D. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS (MUTCD), CURRENT EDITION, WITH WSDOT MODIFICATIONS E. THE INTERNATIONAL FIRE CODE, CURRENT EDITION F. UNIFORM PLUMBING CODE (UPC) WITH CITY AMENDMENTS. G. NATIONAL ELECTRICAL CODE (NEC), CURRENT EDITION. CURRENT EDITlONS OF THESE STANDARDS SHALL BE USED WHICH EXIST ON THE DATE OF CONTRACT ACCEPTANCE. CONTRACTOR SHALL OBTAIN COPIES OF THESE PUBLICATIONS. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION, SUPPLIES, AND INCIDENTALS REQUIRED TO COMPLETE ALL WORK SHOWN ON THESE DRAWINGS AND TO OBTAIN ACCEPTANCE BY THE CITY AND THE PROJECT OWNER. THE INTENT OF THESE DRAWINGS IS TO PRESCRIBE A COMPLETE WORK. OMISSIONS FROM THE DRAWINGS OF DETAILS OF WORK WHICH ARE NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING THE OMITTED WORK. ANY PROPOSED ALTERATIONS BY THE CONTRACTOR AFFECTING THE REQUIREMENTS AND INFORMATION IN THESE DRAWINGS SHALL BE IN WRITING AND WILL REQUIRE APPROVAL OF THE ENGINEER AND INSPECTOR. PROJECT SPECIFICATIONS CONTRACTOR SHALL OBTAIN A RIGHT OF WAY PERMIT PRIOR TO COMMENCING ANY WORK LOCATED IN THE CITY'S RIGHT OF WAY. ALL WORK PERFORMED IN THE CITY'S RIGHT OF WAY SHALL ADHERE TO DRAWINGS, STANDARD SPECIFICATIONS, AND REQUIREMENTS OUTLINED IN THE RIGHT OF WAY PERMIT. WORK IN CITY RIGHT OF WAY THE IRIS GROUP IS REQUIRED BY THE CITY TO PROVIDE RECORD DRAWING CERTIFICATION PRIOR TO FINAL CITY ACCEPTANCE. THE IRIS GROUP WILL NOT CERTIFY RECORD DRAWINGS WITHOUT INSPECTION OF BELOW GRADE UTILITIES AND STRUCTURES. PRIOR TO BACKFILLING, CONTRACTOR SHALL NOTIFY THE IRIS GROUP OF NECESSARY INSPECTIONS. THE CONTRACTOR SHALL MAINTAIN ONE SET OF APPROVED PLANS ONSITE AND SHALL MARK, IN RED, ANY CHANGES TO THE PLANS THAT OCCUR DURING CONSTRUCTION. RECORD DRAWINGS IF UNSUITABLE MATERIALS AS DEFINED BY THE STANDARD SPECIFICATIONS ARE ENCOUNTERED, THIS MATERIAL SHALL BE REMOVED TO THE DEPTH REQUIRED BY THE ENGINEER OR INSPECTOR AND REPLACED WITH SUITABLE MATERIALS. UNSUITABLE MATERIAL SHALL BE REMOVED FROM THE SITE AND HAULED TO A WASTE SITE OBTAINED BY THE CONTRACTOR. PRIOR TO REMOVAL, CONTRACTOR SHALL NOTIFY PROJECT OWNER. REMOVAL OF UNSUITABLE MATERIALS SEE SOILS REPORT PREPARED BY QUALITY GEO NORTHWEST, DATED 4/27/2022. GEOTECHNICAL INFORMATION NAD 1983(2011) SOUTH ZONE; PER RTK GPS TIES AND THE WASHINGTON STATE REFERENCE NETWORK (WSRN). UNITS OF MEASUREMENT ARE U.S. SURVEY FEET. HORIZONTAL DATUM TOPOGRAPHIC INFORMATION DEPICTED IN THESE DRAWINGS WAS PROVIDED IN A SURVEY BY INFORMED LAND SURVEY, DATED 10/25/22. ALL EXISTING FEATURES AND TOPOGRAPHY SHOWN SHALL BE VERIFIED PRIOR TO BEGINNING CONSTRUCTION. ANY AND ALL DISCREPANCIES FOUND BETWEEN ACTUAL EXISTING CONDITIONS AND THE EXISTING CONDITIONS SHOWN HERE SHALL BE IDENTIFIED TO THE PROJECT ENGINEER PRIOR TO CONTINUANCE OF ANY WORK. TOPOGRAPHIC DATA CONSTRUCTION NOTES 1 - C1 COVER 2 - C2 DEMOLITION AND TESC 3 - C3 SITE AND HORIZONTAL CONTROL 4 - C4 GRADING AND DRAINAGE 5 - C5 UTILITIES 6 - C6 DETAILS 1 7 - C7 DETAILS 2 SHEET INDEX MM RHOTON RD CIVIL IMPROVEMENT PLANS YELM, WA 1. THE CONTRACTOR SHALL OBTAIN ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM (CITY) PRIOR TO THE START OF CONSTRUCTION. A GRADING PERMIT FOR STORM POND CONSTRUCTION MAY BE REQUIRED. 2. STORM DRAIN PIPE SHALL BE ON THE WSDOT QUALIFIED PRODUCTS LIST FOR THE SPECIFICATION LISTED BELOW: A. PLAIN CONCRETE STORM SEWER PIPE OR REINFORCED CONCRETE STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.7. B. SOLID WALL PVC STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9- 05.12(1). C. DUCTILE IRON SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.13. D. HANCOR BLUE SEAL â„¢ AND ADVANCED DRAINAGE SYSTEMS (ADS/HANCOR) N-12 HDPE AND (ADS/HANCOR) SANITITE UP TO 36" IN DIAMETER PER WSDOT STANDARD SPECIFICATIONS 9-05.20 AND 9-05.24. E. CONTECH DUROMAXX STEEL RIB REINFORCED POLYETHYLENE PIPE, IN DIAMETERS FROM 24 INCH TO 60 INCH PER WSDOT STANDARD SPECIFICATION 9-05.22. 3. ALL STORM DRAINAGE SYSTEMS SHALL BE AIR TESTED AT 4 PSI EXCEPT CONCRETE PIPE, WHICH SHALL BE TESTED PER WSDOT/APWA STANDARD FOR CONCRETE STORM PIPE. ALL FLEXIBLE PIPE SHALL BE MANDREL TESTED PER WSDOT/APWA STANDARDS. TESTING SHALL BE DONE BY THE CONTRACTOR. 4. TESTING OF THE STORM SEWER SHALL INCLUDE VIDEOTAPING OF THE MAIN BY THE CONTRACTOR. IMMEDIATELY PRIOR TO VIDEOTAPING, ENOUGH WATER SHALL BE RUN DOWN THE LINE SO IT COMES OUT THE LOWER CATCH BASIN. A COPY OF THE VIDEO TAPE SHALL BE SUBMITTED TO THE CITY. ACCEPTANCE OF THE LINE WILL NOT BE MADE UNTIL AFTER THE TAPE HAS BEEN REVIEWED AND APPROVED BY THE CITY. TESTING SHALL TAKE PLACE AFTER ALL UNDERGROUND UTILITIES ARE INSTALLED AND COMPACTION OF THE ROADWAY SUBGRADE IS COMPLETE. 5. SPECIAL STRUCTURES, OIL/WATER SEPARATORS AND OUTLET CONTROLS SHALL BE INSTALLED PER PLANS AND MANUFACTURERS' RECOMMENDATIONS. WHERE OIL/WATER SEPARATORS ARE CONNECTED TO A SEWER SYSTEM, THEY SHALL BE INSTALLED WITH A P-TRAP OR CHECK VALVE TO PREVENT ODORS. 6. ALL DISTURBED AREAS SHALL BE STABILIZED IN ACCORDANCE WITH MINIMUM REQUIREMENT 2 OF THE LATEST EDITION OF THE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON (SWMMWW). FOR SITES WHERE VEGETATION HAS BEEN PLANTED THROUGH HYDRO SEEDING, THE FINANCIAL GUARANTEE WILL NOT BE RELEASED UNTIL THE VEGETATION HAS BEEN THOROUGHLY ESTABLISHED. 7. WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", THE CONTRACTOR SHALL EXPOSE SUCH CONNECTION POINTS AND FITTINGS 48 HOURS PRIOR TO DISTRIBUTING SHUTDOWN NOTICES. 8. ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER AND THE CITY'S CIVIL REVIEW ENGINEER. 9. ALL STORM PIPE SHALL BE A MINIMUM OF 12-INCH DIAMETER FOR MAINS AND CROSSINGS. WHEN PRIVATE STORMWATER (I.E. ROOF, LOT OR FOOTING DRAINS) CANNOT BE INFILTRATED ON INDIVIDUAL LOTS, THE MINIMUM STANDARD PIPING CONNECTION TO THE PUBLIC SYSTEM SHALL BE 8-INCH PVC. THE 8-INCH MAIN USED FOR CONNECTION SHALL BEGIN AT THE RIGHT-OF-WAY, AND THE CONNECTION TO THE CATCH BASIN OR MANHOLE SHALL BE CORED AND GROUTED. 10. ALL STORM MAINS AND RETENTION/DETENTION AREAS SHALL BE STAKED FOR GRADE AND ALIGNMENT BY AN ENGINEERING OR SURVEY FIRM LICENSED TO PERFORM SUCH WORK. 11. THE MINIMUM STAKING OF STORM SEWER SYSTEMS SHALL BE IN ACCORDANCE WITH SECTION 3.00.050 OF THESE STANDARDS, AND AS FOLLOWS: A. STAKE LOCATION OF ALL CATCH BASINS, MANHOLES AND OTHER FIXTURES FOR GRADE AND ALIGNMENT. B. STAKE LOCATION, SIZE, AND DEPTH OF RETENTION/DETENTION FACILITY. C. STAKE FINISHED GRADE OF ALL STORMWATER FEATURES, INCLUDING BUT NOT LIMITED TO CATCH BASIN/MANHOLE RIM ELEVATIONS, OVERFLOW STRUCTURES, WEIRS, AND INVERT ELEVATIONS OF ALL PIPES IN CATCH BASINS, MANHOLES, AND PIPES THAT DAYLIGHT. 12. PIPE MATERIALS USED FOR STORMWATER CONVEYANCE SHALL BE AS APPROVED BY THE CITY. PIPE SIZE, SLOPE, COVER, ETC., SHALL BE AS SPECIFIED IN THE CITY OF YELM DEVELOPMENT GUIDELINES AND ENGINEERING STANDARDS. 13. ALL DRIVEWAY CULVERTS SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. CULVERTS SHALL HAVE BEVELED END SECTIONS TO MATCH THE SIDE SLOPE. 14. IF DRAINAGE OUTLETS (STUB-OUTS) ARE TO BE PROVIDED FOR EACH INDIVIDUAL LOT, THE STUB OUTS SHALL CONFORM TO THE FOLLOWING: A. EACH OUTLET SHALL BE LOCATED AT THE LOWEST ELEVATION ON THE LOT, TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE. EACH OUTLET SHALL HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORM WATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A 5-FOOT HIGH, 2"X 4" STAKE MARKED "STORM" OR "DRAIN." THE STUB-OUT SHALL VISIBLY EXTEND ABOVE SURFACE LEVEL AND BE SECURED TO THE STAKE. C. PIPE MATERIAL SHALL BE AS APPROVED BY THE CITY. D. DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. E. THE DEVELOPER AND/OR CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB-OUT CONVEYANCE LINES WITH RESPECT TO THE UTILITIES (E.G., POWER, GAS, TELEPHONE, TELEVISION). F. ALL INDIVIDUAL STUB-OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOMEOWNER. 15. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO APPROVED PLANS ON FILE WITH THE CITY. ANY MATERIAL DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY. 16. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR SIMILARLY STABILIZED TO THE SATISFACTION OF THE CITY. FOR SITES WHERE GRASS HAS BEEN PLANTED THROUGH HYDRO SEEDING, THE PERFORMANCE BOND WILL NOT BE RELEASED UNTIL THE GRASS HAS BEEN THOROUGHLY ESTABLISHED, UNLESS OTHERWISE APPROVED BY THE CITY. 17. ALL BUILDING DOWNSPOUTS ON COMMERCIAL SITES SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS OTHERWISE APPROVED BY THE CITY. 18. ALL EROSION CONTROL AND STORMWATER FACILITIES SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE CONTRACTOR DURING THE CONSTRUCTION PHASE OF THE DEVELOPMENT PROJECT. 19. NO FINAL CUT OR FILL SLOPE SHALL EXCEED TWO (2) HORIZONTAL TO ONE (1) VERTICAL WITHOUT STABILIZATION BY ROCKERY OR BY A STRUCTURAL RETAINING WALL. 20. THE PROJECT ENGINEER SHALL VERIFY THE LOCATIONS, WIDTHS, THICKNESSES, AND ELEVATIONS OF ALL EXISTING PAVEMENTS AND STRUCTURES, INCLUDING UTILITIES AND OTHER FRONTAGE IMPROVEMENTS, THAT ARE TO INTERFACE WITH NEW WORK, AND PROVIDE ALL TRIMMING, CUTTING, SAW CUTTING, GRADING, LEVELING, SLOPING, COATING, AND OTHER WORK, INCLUDING MATERIALS NECESSARY TO CAUSE THE INTERFACE WITH EXISTING WORKS TO BE PROPER, WITHOUT CONFLICT, ACCEPTABLE TO THE PROJECT ENGINEER AND THE CITY'S CIVIL REVIEW ENGINEER, COMPLETE IN PLACE, AND READY TO USE. 21. COMPACTION OF ALL FILL AREAS SHALL BE PER CURRENT APWA SPECIFICATIONS. FILL SHALL BE PROVIDED IN 6" MAXIMUM LIFTS AND SHALL BE COMPACTED TO 95 PERCENT OF ITS MAXIMUM RELATIVE DENSITY. STORMWATER GENERAL NOTES (CITY) NAVD 88 PER RTK GPS TIES AND THE WASHINGTON STATE REFERENCE NETWORK (WSRN). UNITS OF MEASUREMENT ARE U.S. SURVEY FEET. VERTICAL DATUM LOT 3 OF SHORT SUBDIVISION NO. SS-00-8255-YL, AS RECORDED ON DECEMBER 18, 2000, UNDER AUDITOR'S FILE NOS. 3327633 AND 3327634. IN THURSTON COUNTY, WASHINGTON. LEGAL DESCRIPTION 1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS, AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL IN ACCORDANCE WITH MUTCD. PRIOR TO DISRUPTION OF ANY TRAFFIC, TRAFFIC CONTROL PLANS SHALL BE PREPARED AND SUBMITTED TO THE CITY FOR APPROVAL. NO WORK SHALL COMMENCE UNTIL ALL APPROVED TRAFFIC CONTROL IS IN PLACE. 3.ALL CURB AND GUTTER, STREET GRADES, SIDEWALK GRADES, AND ANY OTHER VERTICAL AND/OR HORIZONTAL ALIGNMENT SHALL BE STAKED BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK. 4.WHERE NEW ASPHALT JOINS EXISTING, THE EXISTING ASPHALT SHALL BE CUT TO A NEAT VERTICAL EDGE AND TACKED WITH ASPHALT EMULSION TYPE CSS1 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. THE NEW ASPHALT SHALL BE FEATHERED BACK OVER EXISTING TO PROVIDE FOR A SEAL AT THE SAW CUT LOCATION AND THE JOINT SEALED WITH GRADE AR-4000W PAVING ASPHALT. 5.COMPACTION OF SUBGRADE, ROCK, AND ASPHALT SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. 6.SUBGRADE INSPECTION SHALL BE PERFORMED BY AN APPROVED TESTING FIRM AND FORMS SHALL BE INSPECTED FOR LINE AND GRADE BY AN ENGINEER BEFORE POURING CONCRETE. 7.CERTIFICATION AS TO CONFORMANCE SHALL BE PROVIDED TO THE CITY PRIOR TO ACCEPTANCE OF WORK. 8.THE CONTRACTOR/DEVELOPER SHALL FURNISH AND INSTALL ALL PERMANENT SIGNING. STREET CONSTRUCTION NOTES UTILITY LOCATE NOTE THE LOCATION OF EXISTING UTILITIES SHOWN HEREON ARE APPROXIMATE AND ARE BASED ON INFORMATION PROVIDED BY THE SURVEYOR AND FROM COUNTY RECORDS. OLYMPIC ENGINEERING ASSUMES NO RESPONSIBILITY FOR THE EXACT LOCATION OF EXISTING UTILITIES SHOWN OR NOT SHOWN HEREON CONTRACTOR SHALL VERIFY THE EXACT SIZE, DEPTH, AND LOCATION OF EXISTING UTILITIES AND CALL FOR UNDERGROUND LOCATE AT 811 A MINIMUM OF 48-HOURS PRIOR TO CONSTRUCTION START. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES RESULTING FROM FAILURE TO LOCATE EXISTING UTILITIES. ACC ASPHALTIC CEMENT CONCRETE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APPROX APPROXIMATE(LY) CB CATCH BASIN CL CLASS CMP CORRUGATED METAL PIPE CO CLEANOUT CONC CONCRETE CPEP CORRUGATED POLYETHYLENE PIPE E EASTING FFE FINISH FLOOR ELEVATION FG FINISHED GRADE FL FLANGED (PIPING) FL FLOWLINE (GRADING) HDPE HIGH DENSITY POLYETHYLENE HMA HOT MIX ASPHALT ID INSIDE DIAMETER IE INVERT ELEVATION MH MANHOLE MIN MINIMUM N NORTH(ING) OC ON CENTER OFF OFFSET PCC PORTLAND CEMENT CONCRETE PSI POUNDS PER SQUARE INCH STA STATION SS SANITARY SEWER SD STORM DRAIN STD STANDARD TESC TEMPORARY EROSION AND SEDIMENT CONTROL TEMP TEMPORARY TPN TAX PARCEL NUMBER TYP TYPICAL ABBREVIATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 X XXX SD SD FD FD RD RD SD SD W W SS SS FM FM OT OT UGP UGP OHP OHP G G UT UT W W SS SS G G UT UT UGP UGP OHP OHP OT OT FM FM RD RD FD FD * SEE PROJECT SURVEY FOR EXISTING FEATURES. HATCH AND LINETYPE SCALES MAY NOT MATCH PLAN. SITE ·EXISTING HARD SURFACE: 0 SF ·EXISTING HARD SURFACE TO REMAIN: 0 SF ·REPLACED HARD SURFACE:0 SF ·CONVERTED IMPERVIOUS TO PERVIOUS: 0 SF ·NEW HARD SURFACE:126,671 SF ·TOTAL NEW PLUS REPLACED HARD SURFACE:126,671 SF ·TOTAL HARD SURFACE AFTER PROJECT:126,671 SF ·NEW POLLUTION GENERATING HARD SURFACE:116,816 SF ·PROPOSED EFFECTIVE HARD SURFACE:0 SF ·DISTURBED AREA:158,558 SF SITE COVERAGE DATA SITE DATA PARCEL #:64300800303 SITE ADDRESS: 906 RHOTON RD SE YELM, WA 98597 GROSS ACREAGE: 3.64 AC (PER SURVEY DATA) SURVEY:BY O'BUNCO ENGINEERING DATED 4/5/22 EXISTING USE: VACANT PRESIDING JURISDICTION:CITY OF YELM, WA G G G G G G G G G G G G G W W W W W W W W W W W W W OH P OH P OH P OH P OH P OH P OH P OH P OH P OH P O H P O H P SD SD W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS 3 2 7 327 32 7 32 7 3 2 7 32 8 329 331 332 33 3 33 4 33 6 33 7 33 8 3 3 9 3 2 8 328 32 8 32 9 33 1 33 2 33 3 33 4 33 6 3 3 7 3 3 8 3 3 9 3 3 9 3 2 8 3 2 9 3 3 1 33 2 3 3 3 3 3 4 3 3 6 3 3 7 3 3 8 341 342 34 1 34 2 32 8 FI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M DE M O A N D T E S C NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C2 2 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 SCALE IN FEETSCALE IN FEET 30150 KEY NOTES 1.PROPOSED STABILIZED CONSTRUCTION ENTRANCE PER DETAIL 2/C6 2.PROPOSED SILT FENCE PER DETAIL 3/C6 3.PROPOSED STOCKPILE AREA 4.PROPOSED LIMITS OF DISTURBANCE SHOWN 1' OUTSIDE THE ACTUAL LIMITS OF DISTURBANCE FOR CLARITY. THERE SHALL BE NO OFFSITE DISTURBANCE EXCEPT TO CONSTRUCT THE OFFSITE IMPROVEMENTS SHOWN HEREIN. 5.LOCATE AND PROTECT EXISTING WATER MAIN TO REMAIN. 6.LOCATE AND PROTECT EXISTING GAS LINE TO REMAIN. 7.LOCATE AND PROTECT EXISTING SANITARY SEWER FORCE MAIN TO REMAIN. 8.PROTECT EXISTING UTILITY POLE, GUY WIRE, AND ANCHOR. 9.PROPOSED SAWCUT. DEMOLISH AND REMOVE ALL ASPHALT PAVING BETWEEN THE SAWCUT LINE AND EASTERN EDGE OF PAVEMENT. 10.COORDINATE WITH ADJACENT PROPERTY OWNER TO RELOCATE MAILBOX # 1 2 3 4 5 6 7 8 9 10 T N:597010.02 E:1115872.04 N:596986.02 E:1115889.15 N:596973.52 E:1115906.07 N:596909.36 E:1115869.58 N:596943.52 E:1115905.50 N:596969.31 E:1116063.77 N:596940.61 E:1116014.98 N:596912.83 E:1116062.26 N:596892.63 E:1116069.72 N:596870.82 E:1116081.15 N:596807.84 E:1116079.47 N:596809.65 E:1116011.49 N:596872.50 E:1116018.17 N:596874.44 E:1115945.19 N:596930.60 E:1115941.69 N:596937.03 E:1115887.84 N:596749.27 E:1115949.86 N:596747.67 E:1116009.84 N:596722.32 E:1115949.14 N:596708.10 E:1116482.37 N:596960.43 E:1116396.75 N:596972.31 E:1116403.29 N:596689.65 E:1116499.19 N:596706.12 E:1115881.68 N:596869.23 E:1115953.06 N:596867.63 E:1116013.04 R 5 ' R5' R 5 ' R5' R2 6 ' R 2 6 ' R10 ' R 5 ' N:596917.43 E:1115946.34 N:596937.18 E:1115955.87 N:596935.50 E:1116018.85 S88° 28' 21"E 514.32' S 1 8 ° 4 4 ' 3 3 " E 2 9 8 . 4 9 ' S88° 28' 21"E 617.73' S0 1 ° 3 1 ' 3 9 " W 2 8 0 . 0 0 ' FI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M SI T E A N D H O R I Z O N T A L CO N T R O L NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C3 3 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 SCALE IN FEETSCALE IN FEET 30150 KEY NOTES 1.PROPOSED 60'X120' METAL BUILDING PER ARCHITECTURAL PLANS BY OTHERS 2.PROPOSED PARKING LOT LANDSCAPING 3.PROPOSED CONCRETE SIDEWALK PER DETAIL 4/C6 4.PROPOSED BIORETENTION FACILITY. SEE SHEET C4 FOR DETAILS. 5.PROPOSED TRANSFORMER. DESIGN BY OTHERS. 6.PROPOSED PRELOS 1500 STEP TANK. SEE SHEET C5 FOR DETAILS. 7.PROPOSED ACCESSIBLE PARKING STALL WITH ADA SYMBOL PER DETAIL 5/C6 8.PROPOSED 8' X 20' ENCLOSED TRASH AND RECYCLING PAD 9.PROPOSED 6" STEEL PIPE BOLLARD (TYP) 10.PROPOSED FIRE TRUCK HAMMERHEAD TURNAROUND PER INTERNATIONAL FIRE CODE 11.PROPOSED HEAVY DUTY HMA SECTION PER BIDDER DESIGN (TYP) 12.PROPOSED STANDARD DUTY HMA SECTION PER BIDDER DESIGN (TYP) 13.PROPOSED GRAVEL SECTION PER BIDDER DESIGN (TYP) 14.PROPOSED CONCRETE WHEEL STOP PER DETAIL 6/C6 (TYP) 15.PROPOSED ADA SIGN PER DETAIL 7/C6 # 1 2 3 3 3 3 4 5 5 6 13 7 8 10 30 ' 23' 23 ' 20 ' 9' 5' 5' 60' 12 0 ' R35 ' R 3 5 ' R25 ' 45 ' 67' 11 5 ' 70'20 ' 20' 60 ' 23' 7' 5' 5' 27 ' R5 'R5' 20 ' 9' 11 12 2.5' 14 15 9 SD SD SD T RD RD RD RD RD RD RD RD RD FG 328.84 FG 328.84 FG 328.84 FG 328.84 FG 327.64 FG 328.84 FG 328.84 FG 328.76 FG 328.76 FG 327.62 FG 327.50 FG 327.62 FG 327.75 FG 327.69 FG 327.42 FG 327.49 FG 327.34 FG 328.09 FG 328.76 FG 328.74 FG 327.95 FG 328.29 FG 328.51 FG 328.73 FG 328.73 FG 327.75 FG 327.20 FG 327.40 FG 327.50 FG 328.83FG 327.84 FG 327.26 FG 327.34 FG 327.37 FG 328.77 FG 328.42 FG 328.42 FG 328.76 FG 328.77 FG 328.42 -1 . 8 % -1 . 7 % 0.0% -0.0% FG 328.25 FG 328.26 FG 328.13 FG 328.36FG 328.48FG 328.63 FG 328.65 FG 328.75 FG 328.54 FG 328.62 FG 327.43 FG 327.14 FG 327.09 FG 327.00 FG 327.10 FG 327.19 FG 328.35 FG 328.25 FG 328.76 FG 327.62FG 327.64 FG 333.20FG 330.80 FG 336.40 FG 339.00 FG 341.20 FG 340.20 FG 341.98 FG 341.75 FG 335.40FG 332.60 FG 338.58 FG 327.08 FG 327.29 FG 327.20 FG 327.15 FG 324.49 FG 327.00 ME 327.04 FG 325.34 ME 327.82 FG 326.14 ME 327.91 FG 329.32 ME 330.23 FG 331.70 ME 335.02 FG 334.88ME 337.60 FG 337.50 ME 339.73 ME 339.17 ME 339.30 ME 339.17 ME 338.79ME 338.44ME 334.30ME 328.46 ME 328.03ME 327.80ME 327.29ME 327.35ME 327.67 ME 326.95 ME 327.99 ME 327.51 ME 327.70 ME 327.87 3 2 7 327 32 7 32 7 3 2 7 32 8 329 331 332 33 3 33 4 33 6 33 7 33 8 3 3 9 3 2 8 328 32 8 32 9 33 1 33 2 33 3 33 4 33 6 3 3 7 3 3 8 3 3 9 3 3 9 3 2 8 3 2 9 3 3 1 33 2 3 3 3 3 3 4 3 3 6 3 3 7 3 3 8 341 342 34 1 34 2 32 8 32 5 32 4 32 6 32 7 3 3 0 3 3 5 3 4 0 32 8 328 3 2 8 3 2 9 3 3 1 3 3 2 3 3 3 3 3 4 3 3 6 3 3 7 3 3 8 3 3 9 3 4 1 328 328 325 326 327 3 2 5 3 2 6 3 2 7 33 0 327 328 329 33 1 335 332 333 334 336 337 338 339 3 4 0 N:596732.84 E:1115892.40 N:596912.78 E:1115897.20 N:596701.06 E:1116484.03 19 0 ' FI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M GR A D I N G A N D D R A I N A G E NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C4 4 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 SCALE IN FEETSCALE IN FEET 30150 KEY NOTES 1.PROPOSED ROOF DRAIN CLEANOUT RIM: 328.81 IE: 327.31 2.PROPOSED 40 LF 6" ROOF DRAIN PIPE AT 0.02 FT/FT GRADE 3.PROPOSED ROOF DRAIN CLEANOUT RIM: 328.75 IE: 326.51 4.PROPOSED 84 LF 6" ROOF DRAIN PIPE AT 0.024 FT/FT GRADE 5.PROPOSED ROOF DRAIN CLEANOUT RIM: 328.81 IE: 327.31 6.PROPOSED 58 LF 6" ROOF DRAIN PIPE AT 0.02 FT/FT GRADE 7.PROPOSED ROOF DRAIN CLEANOUT RIM: 328.81 IE: 326.15 8.PROPOSED 84 LF 6" ROOF DRAIN PIPE AT 0.02 FT/FT GRADE 9.PROPOSED QUARRY SPALL ENERGY DISSIPATION PAD 10.PROPOSED 12" CORRUGATE METAL CULVERT # 1 C4 1 2 34 5 6 78 1.ROOF DRAIN PIPE AND CLEANOUTS SHALL BE PER DETAIL 8/C6 2.BIORETENTION POND SHALL BE CONSTRUCTED PER DETAIL 1/C7. DURING CONSTRUCTION DO NOT DRIVE OR TRACK VEHICLES OR EQUIPMENT OVER THE PROPOSED BIORETENTION POND AREA. 3.AFTER FINAL EXCAVATION OF THE BIORETENTION POND, COMPLETE INFILTRATION TESTING IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON AND SUBMIT TESTING RESULTS TO PROJECT ENGINEER. IF THE DESIGN INFILTRATION RATE DETERMINED THROUGH TESTING IS LESS THAN 8 IN/HR, THE POND WILL NEED TO BE REDESIGNED PRIOR TO BRINGING THE POND ONLINE. 4.BIORETENTION POND SURFACE MATERIAL SHALL BE PER DETAIL 1/C7. 5.BIORETENTION POND SHALL BE PLANTED IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON. NOTES 9 9 IE: 324.47 IE: 324.47 323.70 327.00 327.00 323.70 DESIGN WATER SURFACE ELEVATION: 325.20 FREEBOARD SURFACE ELEVATION: 327.00 BIORETENTION SOIL MIX PER ECOLOGY STANDARDS 18' 3:1 3:1 BIORETENTION POND SECTION NOT TO SCALE 1 R1 7 ' R17 ' IE: 324.79 IE: 324.69 10 SD SD SD FM FM FM W W W W W W U G P UGP UGP U G P UG P UG P UG P T RD RD RD RD RD RD RD RD RD UGP UGP G G G G G G G G G G G G W W W W W W W W W W W W OH P OH P OH P OH P OH P OH P OH P OH P OH P OH P O H P SD SD W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS FI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M UT I L I T I E S NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C5 5 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 SCALE IN FEETSCALE IN FEET 30150 KEY NOTES 1.PROPOSED PRIMARY POWER PER PLANS BY OTHERS 2.PROPOSED TRANSFORMER PER PLANS BY OTHERS 3.PROPOSED SECONDARY POWER PER PLANS BY OTHERS 4.EXISTING 8" WATER MAIN. MATERIAL IS UNKNOWN. 5.PROPOSED CONNECTION TO EXISTING WATER MAIN PER DETAIL 2/C7. RESTORE IN RIGHT OF WAY PER DETAIL 4/C7. 6.PROPOSED 1.5" WATER METER AND SERVICE PER DETAIL 2/C7 7.PROPOSED 1.5" CL200 PVC WATER LINE 8.PROPOSED BUILDING DRAIN CONNECTION SIZED PER BUILDING PLANS 9.PROPOSED PRELOS 1500 STEP TANK PER DETAIL 3/C7 10.PROPOSED 1.25" SCH80 PVC PRESSURIZED SEPTIC TRANSPORT LINE AT MINIMUM BURY DEPTH OF 3' 11.PROPOSED SERVICE BOX WITH VALVES PER DETAIL 5/C7. SERVICE SIZE SHALL BE 2". 12.PROPOSED CONDUCTORS IN CONDUIT FOR PUMP POWER AND CONTROL. DESIGN SHALL BE BY ELECTRICAL ENGINEER OR QUALIFIED ELECTRICIAN. CONDUIT ROUTE IS DIAGRAMMATICALLY SHOWN. 13.PROPOSED WATER TIGHT CONTROL BOX WITH ALARM PER DETAIL 6/C7. DESIGN BY OTHERS. 14.PROPOSED SANITARY SEWER CLEANOUT. MATCH UPSTREAM CONNECTING PIPE SIZE FROM BUILDING. 15.PROPOSED 1.25" SCH80 PVC PRESSURIZED SEPTIC TRANSPORT LINE AT MINIMUM BURY DEPTH OF 3' 16.EXISTING 4" STEP MAIN. MATERIAL IS UNKNOWN. CONNECT TO EXISTING STEP MAIN PER DETAIL 5/C7. SERVICE SIZE SHALL BE 2". # 1 2 3 5 4 6 7 8 9 10 11 14 15 16 17 12 13 FI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M DE T A I L S 1 NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C6 6 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 DETAIL NOT TO SCALE DETAIL NOT TO SCALE DETAIL NOT TO SCALE CONCRETE WHEEL STOP DETAIL NOT TO SCALE ACCESSIBLE PARKING SYMBOL DETAIL NOT TO SCALE ACCESSIBLE PARKING SIGN DETAIL NOT TO SCALE 7 5 6 4 3 2 POST CONSTRUCTION SOIL QUALITY AND DEPTH DETAIL NOT TO SCALE 1 ROOF DRAIN DETAIL NOT TO SCALE 6" CLEANOUT W/ HREADED CAP FINISHED GRADE DOWNSPOUT ADAPTER INSERTED IN RISER PIPE BUILDING FACE 6" 45° WYE 6" 45° BEND 4" x 6" BACKWARDS REDUCER TO 6" WYE 6" SDR35 PVC STORM DRAIN 6" SDR35 PVC STORM DRAIN 4" 90° BEND 4" SDR35 PVC ROOF DRAIN (TYP) 1.4" ROOF DRAIN PIPE SHALL BE SDR 35 PVC AND SHALL BE AT A MINIMUM 2% GRADE TO DRAIN TO DISCHARGE LOCATION. 2.6" ROOF DRAIN PIPE SHALL BE SDR 35 PVC AND SHALL BE AT A MINIMUM 1% GRADE TO DRAIN TO DISCHARGE LOCATION. 3.ALL DRAIN PIPE TRENCHING AND BACKFILL SHALL BE PER PIPE MANUFACTURER SPECIFICATIONS. 4.ALL PIPE SHALL AT A MINIMUM BE CLEANED VIA FLUSHING PRIOR TO CONNECTION TO DISCHARGE LOCATION. ALL ADDITIONAL TESTING REQUIRED BY THE JURISDICTION SHALL BE COMPLETED BY THE CONTRACTOR. 5.DRAIN FITTINGS SHALL BE SDR 35 PVC FITTINGS. 6.ROOF AND STORM DRAIN PIPE SHALL BE LAID STRAIGHT WITH NO VERTICAL SAGS OR BENDS IN PIPE. HORIZONTAL BENDS SHALL BE CONSTRUCTED WITH WATERTIGHT FITTINGS. 7.45° WYE CLEANOUTS SHALL BE INSTALLED UPSTREAM OF ALL BENDS TOTALING GREATER THAN 45° DEFLECTION. 8.CONNECT ALL DOWNSPOUTS TO ROOF DRAINS WITH SDR 35 PVC FITTINGS. 9.DO NOT CONNECT ROOF DRAIN PIPE TO FOOTING DRAIN PIPE. 10.CLEANOUTS SHALL BE INSTALLED EVERY 50' OF PIPE RUN. 8 FI L E N A M E : Z: \ P \ M M C 0 1 \ C A D \ S h e e t s \ M M C 0 1 C i v i l I m p r o v e m e n t P l a n s V 1 . d w g D A T E / T I M E : 4/ 2 / 2 0 2 4 1 : 0 4 : 0 6 P M DE T A I L S 2 NW 1 / 4 N E 1 / 4 S E C 1 9 T W N 1 7 R N G 2 E W M TH U R S T O N C O U N T Y T P N 6 4 3 0 0 8 0 0 3 0 3 90 6 R H O T O N R D YE L M , W A 9 8 5 9 7 MM R H O T O N R D CI V I L I M P R O V E M E N T P L A N S NDT RCB 04-02-2024 MMC01 NDT C7 7 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICH O L A S D A VID A Y L O RSTATEOFWASHIN G T O N REGIS T E R E D P R O F ESSIONA L E N G INEER T 46113 0 4 -02-2024 DETAIL NOT TO SCALE DETAIL DETAIL NOT TO SCALE DETAIL NOT TO SCALE NOT TO SCALE DETAIL NOT TO SCALE 6 5 4 3 2 PRELOS 1500 DETAIL 3 DETAIL NOT TO SCALE 1