Street light - Falcon side solarDATEREV DESCRIPTION
I HEARBY CERTIFY THIS DOCUMENT WAS PREPARED BY MYSELF OR UNDER
MY DIRECT SUPERVISION THAT I AM A DULY REGISTERED ENGINEER
UNDER THE LAWS OF THE STATE OF XXXXXX.
[THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP]
BY
XX/XX/20230 PRELIMDAW
SHEET:REV:
0
----
----
----
----
COVER SHEET & LOCATION MAPS
THIS DOCUMENT HAS BEEN DRAWN BASED OFF THE MOST RECENT AVAILABLE DATA & AERIAL IMAGERY. THIS INCLUDES RIGHT OF WAY, EXISTING UTILITIES, & PRIVATE PROPERTY LINES. IT REMAINS THE RESPONSIBILITY OF OTHERS TO VERIFY ALL DATA PRIOR AND EXISTING SURRONDING FACILITIES TO VERIFY & CONFLICTS ABOVE & BELOW GRADE. ALL CONSTRUCTION TO FOLLOW XXXXXX GENERAL GUIDELINES. DO NOT SCALE DRAWINGS. CALL 811 PRIOR TO DIGGING.
1170 HOWELL MILL ROAD SUITE 210
ATLANTA, GA 30318
XXXXXX
XXXXX POLICE DEPARTMENT
LICENSE PLATE READER CAMERA
INSTALLATION
CASE NUMBER: XXXXXX
PERMITTING JURISDICTION:
XXXXXX
[THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP]
SPEC.01SPEC.01
11
SCALE: N/A
POLE ELEVATION DETAIL
NOTE:
DRAWINGS BASED ON TYPICAL STREET LIGHT
10
'
-
0
"
(
M
I
N
)
3
ITEM NO.PART NUMBER DESCRIPTION TOTAL WEIGHT (LB)
1
2
3
201-00087 MOUNTING CLAMP 2.0
QTY.
1
1
701-0059 FLOCK SAFETY CAMERA 3.6
1'
-
6
"
(
M
I
N
)
2
1
GRADE
EXISTING FOUNDATION
205-00010
EXISTING STREET LIGHT POLE
GENERAL & CONSTRUCTION NOTES
1. CONTRACTOR SHALL APPLY AND OBTAIN AN APPROVED TRAFFIC CONTROL PLAN IN ACCORDANCE WITH MUTCD AND LOCAL
JURISDICTION STANDARDS.
2. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO ORIGINAL SITE CONDITION TO THE SATISFACTION OF STATE
DEPARTMENT OF TRANSPORTATION AND LOCAL JURISDICTION.
3. ALL WORK SHALL CONFORM TO APPLICABLE ELECTRICAL CODES EXCEPT WHEN STATE DEPARTMENT OF TRANSPORTATION
OR LOCAL JURISDICTION STANDARDS SUPERSEDE.
4. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH SPECIFICATIONS DEFINED BY THE STATE DEPARTMENT OF
TRANSPORTATION OR LOCAL JURISDICTION, UNLESS SPECIFICALLY STATED OR SHOWN OTHERWISE HEREIN.
ADA COMPLIANCE NOTES
1. ALL SIDEWALK CONSTRUCTION SHALL BE IN ACCORDANCE WITH ADA TITLE II, STATE DEPARTMENT OF TRANSPORTATION,
AND LOCAL JURISDICTION STANDARDS,
2. STATE DEPARTMENT OF TRANSPORTATION CURRENT EDITION STANDARDS SHALL BE USED FOR PEDESTRIAN CONTROL
PLANS WHEN CLOSURE OF SIDEWALK IS REQUIRED FOR CONSTRUCTION.
3. MINIMUM CLEAR PEDESTRIAN ACCESS ROUTE (PAR) SHALL BE 48" WIDE.
4. NO OBSTRUCTION IS PERMITTED ALONG THE WIDTH OF THE SIDEWALK. UP TO AN ELEVATION OD 7'-0" ABOVE GRADE.
60W SOLAR KIT 17.0 1
DATEREV DESCRIPTION
I HEARBY CERTIFY THIS DOCUMENT WAS PREPARED BY MYSELF OR UNDER
MY DIRECT SUPERVISION THAT I AM A DULY REGISTERED ENGINEER
UNDER THE LAWS OF THE STATE OF XXXXXX.
[THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP]
BY
XX/XX/20230 PRELIMDAW
SHEET:REV:
0
----
----
----
----
COVER SHEET & LOCATION MAPS
THIS DOCUMENT HAS BEEN DRAWN BASED OFF THE MOST RECENT AVAILABLE DATA & AERIAL IMAGERY. THIS INCLUDES RIGHT OF WAY, EXISTING UTILITIES, & PRIVATE PROPERTY LINES. IT REMAINS THE RESPONSIBILITY OF OTHERS TO VERIFY ALL DATA PRIOR AND EXISTING SURRONDING FACILITIES TO VERIFY & CONFLICTS ABOVE & BELOW GRADE. ALL CONSTRUCTION TO FOLLOW XXXXXX GENERAL GUIDELINES. DO NOT SCALE DRAWINGS. CALL 811 PRIOR TO DIGGING.
1170 HOWELL MILL ROAD SUITE 210
ATLANTA, GA 30318
XXXXXX
XXXXX POLICE DEPARTMENT
LICENSE PLATE READER CAMERA
INSTALLATION
CASE NUMBER: XXXXXX
PERMITTING JURISDICTION:
XXXXXX
[THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP]
SPEC.02
1
2
3
4
7
6
5
1 1/2" TO 3 1/2"
(38 MM TO 89 MM)9/16"
3/8" HEX
0.
0
2
2
"
MCMASTER-CARR QUICK-RELEASE CLAMP FOR FIRM HOSE AND TUBE,
201 STAINLESS STEEL WITH 410 STAINLESS STEEL SCREW
PART NUMBER: 5322K58
MOUNTING CLAMP
MOUNTING HARDWARE TO BE
PROVIDED BY FLOCK SAFETY
NOT USED
FLOCK SAFETY "FALCON" CAMERA
MOUNTING HARDWARE TO BE
PROVIDED BY FLOCK SAFETY
FRONT SIDE ISOMETRIC
10
15
16
"
5 7 16"4 1116"
10
15
16
"
8 NOT USED
MOUNTING HARDWARE TO BE
PROVIDED BY FLOCK SAFETY
TOP FRONT SIDE
1-9
1
4
"
1-
1
0
1
16
"
4
116"
1'
-
4
3 4"
2'-3 15
16"2'-3 15
16"
60 WATT SOLAR PANEL DETAIL (SIDE MOUNTED)
NOT USED
NOT USED
NOT USED