Loading...
Flock pole - Falcon Top SolarDATEREV DESCRIPTION I HEARBY CERTIFY THIS DOCUMENT WAS PREPARED BY MYSELF OR UNDER MY DIRECT SUPERVISION THAT I AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF XXXXXX. [THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP] BY XX/XX/20230 PRELIMDAW SHEET:REV: 0 ---- ---- ---- ---- COVER SHEET & LOCATION MAPS THIS DOCUMENT HAS BEEN DRAWN BASED OFF THE MOST RECENT AVAILABLE DATA & AERIAL IMAGERY. THIS INCLUDES RIGHT OF WAY, EXISTING UTILITIES, & PRIVATE PROPERTY LINES. IT REMAINS THE RESPONSIBILITY OF OTHERS TO VERIFY ALL DATA PRIOR AND EXISTING SURRONDING FACILITIES TO VERIFY & CONFLICTS ABOVE & BELOW GRADE. ALL CONSTRUCTION TO FOLLOW XXXXXX GENERAL GUIDELINES. DO NOT SCALE DRAWINGS. CALL 811 PRIOR TO DIGGING. 1170 HOWELL MILL ROAD SUITE 210 ATLANTA, GA 30318 XXXXXX XXXXX POLICE DEPARTMENT LICENSE PLATE READER CAMERA INSTALLATION CASE NUMBER: XXXXXX PERMITTING JURISDICTION: XXXXXX [THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP] SPEC.01SPEC.01 11 SCALE: N/A POLE ELEVATION DETAIL DESIGN NOTES 1. POLE AND FOUNDATIONS ARE DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES: 1.1.2009/2012/2015/2018/2021 INTERNATIONAL BUILDING CODE 1.2.AASHTO LRFD SPECIFICATIONSFOR STRUCTURAL SUPPORT FOR HIGHWAY SIGNS, LUMIN, TRAFFIC SIGNALS, 2015 EDITION. 2. POLE ANALYSIS AND FOUNDATION DESIGN ARE BASED ON THE FOLLOWINGCRITERIA 2.1.DESIGN WIND SPEED (Vult)):(SEE SECTION 2.6) 2.2.RISK CATEGORY:II 2.3.EXPOSURE CATEGORY:C 2.4.TOPOGRAPHIC CATEGORY:1 2.5.SEISMIC DESIGN CRITERIA: 2.5.1.SOIL SITE CLASS: D (ASSUMED) 2.5.2.SPECTRAL RESPONSE, Ss:1.000g (MAXIMUM) 2.5.3.SPECTRAL RESPONSE, S1:0.400G (MAXIMUM) 2.5.4.SEISMIC DESIGN CATEGORY:B 2.6.STRUCTURE BASE REACTIONS ARE CALCULATED AS FOLLOWS: 2.7.SHOULD ANY OF THE SITE-SPECIFIC PARAMETERS BE HIGHER THAN WHAT IS NOTED ABOVE, THE EOR SHALL BE CONTACTED TO PROVIDE A REVISED DESIGN. 3. FOUNDATIONS ARE DESIGNED BY OTHERS, FLOCK SAFETY SHALL PROVIDE THE CONTRACTOR WITH INSTALLATION SPECIFICATIONS AND GUIDELINES. CONTRACTOR IS RESPONSIBLE FOR VERIFYING SOIL CONDITIONS PRIOR TO INSTALLATION. GENERAL & CONSTRUCTION NOTES 1. CONTRACTOR SHALL CONTACT DESIGNATED AGENCY TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 2. CONTRACTOR SHALL APPLY AND OBTAIN AN APPROVED TRAFFIC CONTROL PLAN IN ACCORDANCE WITH MUTCD AND LOCAL JURISDICTION STANDARDS. 3. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO ORIGINAL SITE CONDITION TO THE SATISFACTION OF STATE DEPARTMENT OF TRANSPORTATION AND LOCAL JURISDICTION. 4. ALL WORK SHALL CONFORM TO APPLICABLE ELECTRICAL CODES EXCEPT WHEN STATE DEPARTMENT OF TRANSPORTATION OR LOCAL JURISDICTION STANDARDS SUPERSEDE. 5. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH SPECIFICATIONS DEFINED BY THE STATE DEPARTMENT OF TRANSPORTATION OR LOCAL JURISDICTION, UNLESS SPECIFICALLY STATED OR SHOWN OTHERWISE HEREIN. ADA COMPLIANCE NOTES 1. ALL SIDEWALK CONSTRUCTION SHALL BE IN ACCORDANCE WITH ADA TITLE II, STATE DEPARTMENT OF TRANSPORTATION, AND LOCAL JURISDICTION STANDARDS, 2. STATE DEPARTMENT OF TRANSPORTATION CURRENT EDITION STANDARDS SHALL BE USED FOR PEDESTRIAN CONTROL PLANS WHEN CLOSURE OF SIDEWALK IS REQUIRED FOR CONSTRUCTION. 3. MINIMUM CLEAR PEDESTRIAN ACCESS ROUTE (PAR) SHALL BE 48" WIDE. 4. NO OBSTRUCTION IS PERMITTED ALONG THE WIDTH OF THE SIDEWALK. UP TO AN ELEVATION OD 7'-0" ABOVE GRADE. DESIGN WIND SPEED (MPH)MOMENT (K-FT)SHEAR (KIP)AXIAL (KIP) 115 2.70 0.280 0.160 125 3.20 0.330 0.160 135 (MAX)3.70 0.380 0.160 ITEM NO.PART NUMBER DESCRIPTION TOTAL WEIGHT (LB) 1 701-0059 FLOCK SAFETY CAMERA 3.6 2 3 201-00087 MOUNTING CLAMP 2.0 QTY. 1 1 4 2.5STD ALUMINUM POLE 2 7 8 "Ø FOUNDATION (BY OTHERS, SEE DESIGN NOTES ITEM 3) GRADE 1' - 6 " ( M I N ) 3 1 2 4 205-00010 PO L E H E I G H T 12 ' - 0 " ( M A X ) BATTERY PACK INSTALLED BEHIND SOLAR PANEL (MAX 2) 701-00111 6.0 2 (MAX)EXTERNAL BATTERY PACK 60W SOLAR KIT 17.0 1 3' ( M I N ) DATEREV DESCRIPTION I HEARBY CERTIFY THIS DOCUMENT WAS PREPARED BY MYSELF OR UNDER MY DIRECT SUPERVISION THAT I AM A DULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OF XXXXXX. [THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP] BY XX/XX/20230 PRELIMDAW SHEET:REV: 0 ---- ---- ---- ---- COVER SHEET & LOCATION MAPS THIS DOCUMENT HAS BEEN DRAWN BASED OFF THE MOST RECENT AVAILABLE DATA & AERIAL IMAGERY. THIS INCLUDES RIGHT OF WAY, EXISTING UTILITIES, & PRIVATE PROPERTY LINES. IT REMAINS THE RESPONSIBILITY OF OTHERS TO VERIFY ALL DATA PRIOR AND EXISTING SURRONDING FACILITIES TO VERIFY & CONFLICTS ABOVE & BELOW GRADE. ALL CONSTRUCTION TO FOLLOW XXXXXX GENERAL GUIDELINES. DO NOT SCALE DRAWINGS. CALL 811 PRIOR TO DIGGING. 1170 HOWELL MILL ROAD SUITE 210 ATLANTA, GA 30318 XXXXXX XXXXX POLICE DEPARTMENT LICENSE PLATE READER CAMERA INSTALLATION CASE NUMBER: XXXXXX PERMITTING JURISDICTION: XXXXXX [THIS SPACE LEFT INTENTIONALLY BLANK FOR STAMP] SPEC.02 1 2.5STD ALUMINUM PIPE PIPE DETAIL LENGTH VARIES PER FOUNDATION DEPTH 2 3 4 7 6 5 FLOCK SAFETY "FALCON" CAMERA MOUNTING HARDWARE TO BE PROVIDED BY FLOCK SAFETY FRONT SIDE ISOMETRIC 10 15 16 " 5 7 16"4 1116" 10 15 16 " MOUNTING HARDWARE TO BE PROVIDED BY FLOCK SAFETY60 WATT SOLAR PANEL DETAIL (TOP MOUNTED) FRONT SIDE ISOMETRIC 1'-914" 2'-4 3 16 " 1 3 1 6 " 1' - 7 5 16 " PIPE SLEEVE MOUNT 1 1/2" TO 3 1/2" (38 MM TO 89 MM)9/16" 3/8" HEX 0. 0 2 2 " MCMASTER-CARR QUICK-RELEASE CLAMP FOR FIRM HOSE AND TUBE, 201 STAINLESS STEEL WITH 410 STAINLESS STEEL SCREW PART NUMBER: 5322K58 MOUNTING CLAMP MOUNTING HARDWARE TO BE PROVIDED BY FLOCK SAFETY FLOCK FOUNDATION DETAIL FOUNDATION ENCASED IN CONCRETE GRADE 3' ( M I N ) 1' NOT USED MOUNTING HARDWARE TO BE PROVIDED BY FLOCK SAFETY 7 9 10" 21 12" 5 3 5" 20 " 22 " 5 15" FRONT SIDEBACKSIDE MODEL 701-00111 SUPPLIED BY FLOCK SAFETY EXTERNAL BATTERY PACK