Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Clarke, Jamie - PV
THIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 2020 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY CITY OF YELM CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: ROOF MOUNT PHOTOVOLTAIC SYSTEM PV-1 PROJECT DETAILS PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B ARRAY DETAILS PV-3 MOUNTING DETAILS PV-3A MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. PV-1 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - GREG ALBRIGHT SITE LOCATION PROJECT DETAILS IN V JB U M AC M S P S U B 31'-1" 3'-3" 6'-11" 56'-2"(E) MAIN SERVICE PANEL (N)INVERTER (N)AC DISCONNECT (E) UTILITY METER (N) SUB PANEL (N)21 CANADIAN SOLAR: CS6R-395MS-HL 123'-8" 60'-3" SITE PLAN SCALE: 1/16" = 1'-0"1 PV-2 FREE D O M F O R E V E R I N D Y 8 . 0 0 T E M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - ROOF AREA: 1852 SQ FT SITE PLAN LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECTAC UTILITY METER JUNCTION BOX INVERTER SUBPANEL MAIN SERVICE PANEL UM JB INV SUB MSP GREG ALBRIGHT TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 1852 SQ FT SINGLE MODULE AREA: 21.14144323 SQ FT TOTAL NUMBER OF MODULES: 21 TOTAL AREA OF MODULES: 443.97 SQ FT ROOF COVERAGE: 23.97% FIRE SPRINKLERS : NO VANCIL LOOP SE IN V JB U M AC M S P S U B 3' 3' (N)21 CANADIAN SOLAR: CS6R-395MS-HL FIRE ACCESS PATHWAYS PV-2A FREE D O M F O R E V E R I N D Y 8 . 0 0 T E M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - ROOF PLAN SCALE: 2/25" = 1'-0"1 NOTES: 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 1852 SQ FT ROOF PLAN WITH MODULES LAYOUT LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECTAC UTILITY METER JUNCTION BOX INVERTER SUBPANEL MAIN SERVICE PANEL UM JB INV SUB MSP TOTAL ROOF AREA: 1852 SQ FT TOTAL ARRAY AREA: 443.97 SQ FT ARRAY COVERAGE: 23.97% SYSTEM DISTRIBUTED WEIGHT: 2.34 LBS UNIRAC: FLASHKIT PRO POINT-LOAD: 28.04 LBS GREG ALBRIGHT PV-2B FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - ARRAY DETAILS ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA ROOF 1 10 20 20 301.23 444.13 SQ FT 211.41 SQ FT ROOF 2 11 20 20 121.23 444.13 SQ FT 232.56 SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT ROOF DETAILS: TOTAL ROOF AREA: 1852 SQ FT TOTAL ARRAY AREA: 443.97 SQFT ARRAY COVERAGE: 23.97% SYSTEM DISTRIBUTED WEIGHT: 2.34 LBS UNIRAC: FLASHKIT PRO POINT-LOAD: 28.04 LBS GREG ALBRIGHT PV MODULE UNIRAC NXT RAIL UNIRAC L-FOOT ATTACHMENTS UNIRAC FLASHKIT PRO UNIRAC NXT UMOUNT RAIL (E) SINGLE LAYER OF COMP SHINGLE (E)RAFTER/TOP-CHORD 5/16"x3.5" SS LAG BOLT WITH MIN 212" THREAD EMBEDMENT, SEALED PENETRATION 5/16"-18 x 2" SERRATED FLANGE HEX SCREW PV MODULE UNIRAC L-FOOT ATTACHMENTS UNIRAC FLASHKIT PRO 3 " M I N . 6 " M A X . 5/16"x3.5" SS LAG BOLT WITH MIN 212" THREAD EMBEDMENT, SEALED PENETRATION DETAIL VIEW (E)RAFTER/TOP-CHORD UNIRAC NXT UMOUNT COMBO CLAMP UNIRAC NXT UMOUNT RAIL CLAMP ASSY 2. 5 " M I N . TABLE 1 - ARRAY INSTALLATION ROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE MAX UNBRACED LENGTH(FT.) STRUCTURAL ANALYSIS RESULT PENETRATION PATTERN MAX ATTACHMENT SPACING (IN.) MAX RAIL OVERHANG(I N.) ROOF 1 20 Comp Shingle Unirac Flashkit Pro 2x4 @ 24" O.C.6 PASS STAGGERED 72 24 ROOF 2 20 Comp Shingle Unirac Flashkit Pro 2x4 @ 24" O.C.6 PASS STAGGERED 72 24 1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY. 2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. 3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PV-3 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - MOUNTING DETAILS STAGGERED DETAIL For Illustration purposes only STACKED DETAIL For Illustration purposes only GREG ALBRIGHT 4 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #10 AWG MUST BE IN EMT CONDUIT STRING-2STRING-1 JUNCTION BOX SOLAREDGE S440 POWER OPTIMIZERS SOLAREDGE S440 POWER OPTIMIZERS 10 CANADIAN SOLAR: CS6R-395MS-HL 11 CANADIAN SOLAR: CS6R-395MS-HL 4 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT TO OTHER LOADS UM(E) 200A / 2P MAIN BREAKER (TOP FED) (N) 60A / 2P SUBPANEL BREAKER (E) 200A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ TO UTILITY UNDERGROUND FEED (N) 125A MINIMUM RATED SUB PANEL 1PH, 120/240V 60HZ (N) 35A / 2P PV BREAKER EXISTING WIRE RUN THROUGH CONDUIT (E) UTILITY METER 3 - #8 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) 60A RATED VISIBLE LOCKABLE LABELED DISCONNECT EATON DG222URB (OR EQUIVALENT) KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED 3 - #8 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) SOLAREDGE SE6000H-USRGM [SI1] INVERTER AC DC RAPID SHUTDOWN SWITCH NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 25.00A @ 240V 25.00 X 1.25 =31.25AMPS 35A BREAKER - OK SEE 705.12 OF 2020 NEC 200 X 1.20 =240 240 -200 =40A ALLOWABLE BACKFEED PV-4 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - THREE LINE DIAGRAM GREG ALBRIGHT PV-5 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO OPTIMIZER 2 10 40 17.21 1 1 40.00 21.52 2 DC OPTIMIZER TO JUNCTION BOX 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER 4 10 40 15.00 1 0.8 32.00 18.75 4 AC INVERTER TO AC DISCONNECT 3 8 55 25.00 1 1 55.00 31.25 5 AC AC DISCONNECT TO POI 3 8 55 25.00 1 1 55.00 31.25 6 AC SUBPANEL TO MSP 3 6 75 60.00 1 1 75.00 60.00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST: PV-6 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - QTY.PART PART #DESCRIPTION 21 110 - MODULES PV-116-395-2 "MFG: CANADIAN, 395W MONO BOB, MFG SKU: CS6R-395MS-HL" 1 120 - INVERTERS INV-120-608 "MFG: SOLAREDGE, 6.0 KW RGM SCREENLESS W/CONSUMPTION MONITORING, MFG SKU: SE6000H-US000BEI4" 1 180 - MONITORING EQUIPMENT ME-180-502 "MFG: SOLAREDGE, CELL MODEM W/5 YRS, MFG SKU: SE-CELL-B-R05-US-S-S2" 21 130 - OPTIMIZERS OPT-130-440-2 "MFG: SOLAREDGE, 440W 60V OPTIMIZER, MFG SKU: S440" 2 260 - FITTINGS/ANCHORS RAC-261-527 "MFG: UNIRAC, JUNCTION BOX, COMP SHINGLE AND RAIL MOUNT APPLICATIONS, MFG SKU: SOLOBOX-D" 2 210 - RAILS RAC-211-201 "MFG: UNIRAC, E-BOSS J-BOX MOUNTING BRACKET, MFG SKU: 00802JB" 1 320 - DISCONNECTS EE-321-060 "MFG: EATON, DISCONNECT, GENERAL DUTY, 2P, 240V, 60A, NON FUSIBLE, NEMA 3R, MFG SKU: DG222URB" 1 150 - LOAD CENTERS / MAIN PANELS EE-151-131 "MFG: EATON, LOAD CENTER, 8 SPACE, 16 CIRCUIT, MAIN LUG, 125A, NEMA 3R, 10KAIC, CURRENT DESIGN, COVER INCLUDED, MFG SKU: BR816L125RP" 6 350 - ELECTRICAL ACCESSORIES EA-350-326 "MFG: STAUBLI MULTI-CONTACT, MC4 CONNECTORS (FEMALE), MFG SKU: PV-KBT4/6I-UR" 6 350 - ELECTRICAL ACCESSORIES EA-350-327 "MFG: STAUBLI MULTI-CONTACT, MC4 CONNECTORS (MALE), MFG SKU: PV-KST4/6I-UR" 210 260 - FITTINGS/ANCHORS RAC-260-550 "MFG: BURNDY, PV WILEY CABLE CLIP THICKNESS RANGE: 1.3 TO 3MM MFG SKU: ACC-FPV180" 37 240 - FOOTINGS RAC-241-250 "MFG: UNIRAC, FLASHKIT PRO - MILL, MFG SKU: 004055M" 18 210 - RAILS RAC-211-100 "MFG: UNIRAC, LIGHT RAIL 168"" MILL, MFG SKU: 315168M" 37 260 - FITTINGS/ANCHORS RAC-261-517 "MFG: UNIRAC, T-BOLT NUT 3/8 X 3/4 SS, MFG SKU: 009020S" 23 220 - MIDS AND ENDS RAC-221-101 "MFG: UNIRAC, UNIVERSAL MID CLAMP - DARK, MFG SKU: 302030D" 23 220 - MIDS AND ENDS RAC-221-209 "MFG: UNIRAC, UNIVERSAL AF SERIES END CLAMP DRK, MFG SKU: 302050D" 8 260 - FITTINGS/ANCHORS RAC-261-600 "MFG: UNIRAC, BONDING SPLICE BAR SERRATED - MILL, MFG SKU: 303019M" 23 260 - FITTINGS/ANCHORS RAC-261-510 "MFG: UNIRAC, MICRO MNT BND T-BOLT 1/4 X 3/4 SS, MFG SKU: 008013S" 6 210 - RAILS RAC-211-209 "MFG: UNIRAC, E-BOSS CONDUIT MOUNT COMP KIT, MFG SKU: 00822CM" 12 210 - RAILS RAC-211-200 "MFG: UNIRAC, E-BOSS RAIL TRAY, MFG SKU: 00802RT" 4 210 - RAILS RAC-211-206 "MFG: UNIRAC, E-BOSS BRIDGE TRAY, MFG SKU: 00802BT" 7 210 - RAILS RAC-211-207 "MFG: UNIRAC, E-BOSS BRIDGE CLIP, MFG SKU: 00802BC" 1 220 - MIDS AND ENDS RAC-223-301 "MFG: SNAP N RACK, TDS, SPEEDSEAL CONDUIT MOUNT KIT, MFG SKU: 242-05164" OCPD SIZES: 35A BREAKER SERVICE LIST: SUB PANEL INSERT EQUIPMENT & SERVICE LIST GREG ALBRIGHT NOTES: M690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY IFC 605.11.3.1(1) & 690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC NEC 690.13(B) INVERTER DC SOLAR PV DC CIRCUIT EVERY 10' ON CONDUIT AND ENCLOSURES SOLAR ELECTRIC PV PANELS 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL !WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS NEC 710.15(C) & 692.9 (C) NEC 690.15 (B) & NEC 690.33(D)(2) DO NOT DISCONNECT UNDER LOAD NEC 705.12(D) & NEC 690.59 !CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.12(D) & NEC 690.59 NEC 705.12(C) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. !WARNING ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED 24 INCH 3 480 VAC 42 INCH 12 INCH 1 INCH FLASH HAZARD BOUNDARY CAL/CM^2 FLASH HAZARD AT 18 INCHES SHOCK HAZARD WHEN COVER IS REMOVED LIMITED APPROACH RESTRICTED APPROACH - 500 V CLASS 00 GLOVES PROHIBITED APPROACH - 500 V CLASS 00 GLOVES LOCATION:16143 VANCIL LOOP SE,YELM, WA 98597 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 25.00A 240V!WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 690.54 NEC 705.12(B)(3)(3) NEC 706.15(C) AND NEC 110.16 PM NEC 705.12(D) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(E) PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT AND ENCLOSURES NEC 690.31 NEC 690.31(D)(2) NEC 690.13(B) PHOTOVOLTAIC DC DISCONNECT 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 MAXIMUM DC VOLTAGE OF PV SYSTEM ARRAY J/B NEC 690.31(G)(3) & (4) 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3)MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX DC-DC CONVERTER OUTPUT CURRENT V A A 16.5 480 15 PV-7 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - LABELS GREG ALBRIGHT 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS (E) MAIN SERVICE PANEL (N) INVERTER (N) AC DISCONNECT (E) UTILITY METER (N) SUB PANEL (N) 21 CANADIAN SOLAR: CS6R-395MS-HL CAUTION: PV-7A FREE D O M F O R E V E R I N D Y 8 . 0 0 T E M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN VANCIL LOOP SE JB PV-8 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - SOLAREDGE OPTIMIZER CHART OPTIMIZER CHART GREG ALBRIGHT 1 1-10 11-20 21-30 31-40 41-50 51-60 2 3 4 5 6 7 8 9 10 IN V JB U M AC M S P SU B 31'-1" 3'-3" 6'-11" 56'-2" 123'-8" 60'-3" PV-9 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET INCIDENT REPORTING: INJURIES - CALL INJURY HOTLINE (855) 400-7233 *If injury is life threatening, call 911 first THEN the Injury Hotline NON-INJURIES - USE MOBILE INCIDENT REPORTING (Auto, Property Damage, Near Miss) NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: NAME: _______________________________________________ ADDRESS: ___________________________________________ NEAREST HOSPITAL: NAME:_______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION: NAME: _______________________________________________ PHONE NUMBER: _____________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O BREAK AND WATER LOG THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS POLICIES INSTRUCTIONS: 1.SCAN QR LINK BELOW TO ACCESS ALL FREEDOM FOREVER SAFETY POLICIES AND PROGRAMS. VANCIL LOOP SE JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access ·Ladders must be inspected before each use. ·Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. ·Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. ·A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). ·Additional notes: Mobile Equipment ·Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. ·Type(s) of mobile equipment (Type/Make/Model): ·Qualified operator(s): Material Handling and Storage ·Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection ·A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. ·First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. ·FPCP (name and title): ·FPU and LPD (name and title): Electrical Safety ·The Electrical Qualified Person (EQP) is required onsite to perform electrical work. ·All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. ·Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. ·EQP (name and tile): Public Protection ·The safety of the Client and Public must be maintained at all times. ·The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. ·Company, Client and Public property shall be protected from falling objects. ·Pets (including dogs) shall be secured by their owners prior to work start. ·The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. ·Crew leader responsible for communication with the client: ·Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing ·All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. ·Crew leader (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): Airborne Contaminants: ·Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) ·Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. ·If yes, list specific tasks and protection in place: Weather and Environment ·The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) ·The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. ·Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. ·Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention ·Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. ·Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. ·New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. ·Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. ·Cool Vests are encouraged for all employees at all times during periods of high heat. ·Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? ·If offsite replenish is necessary, where will you go to replenish water (location/address): ·Who will replenish the drinking water (name): Restroom facilities ·Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. ·Restroom facilities will be (circle one): Onsite - Offsite ·If Offsite, add location name and address: Incident Reporting Procedure ·Contact your Site Supervisor Name: Phone: ·Contact your Manager Name: Phone: ·Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 431636 DESIGNED BY: E.T. CLIENT: JAMIE CLARKE 16143 VANCIL LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165251134 APN: 6927-00-00700 PHONE: (206) 669-3167 EMAIL: JAMIECLARKE618@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 21 X 395 = 8.295 kW SYSTEM SIZE (AC): 6.000 kW @ 240V MODULES: 21 X CANADIAN SOLAR: CS6R-395MS-HL OPTIMIZERS: 21 X SOLAREDGE S440 INVERTER: SOLAREDGE SE6000H-USRGM [SI1] DATE: 4/24/2024 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINK PV INSTALLATION REFERENCESFREEDOM REFERENCES BATTERY INSTALLATION REFERENCES ENPHASE SOLAREDGE TESLAINSTALL HOTLINE TESLA Storage Systems NON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage Systems Misc. Quick Guide FOR INSTALLATION REFERENCE ONLY V1.4 HiKu6 (All -Black) ALL BLACK MONO PERC 380 W - 405 W CS6R-380 1 385 1 390 1 395 1 400 1 405MS-HL MORE POWER Module power up to 405 W 405 W Module efficiency up to 20.7 % (�) Lower LCOE & system cost j' Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Better shading tolerance MORE RELIABLE Minimizes micro -crack impacts *** Heavy snow load up to 8100 Pa, 0 wind load up to 5000 Pa* * For detailed information, please refer to the Installation Manual. �� CanadianSolar 25 Industry Leading Product Warranty on Materials Years and Workmanship* 25j Linear Power Performance Warranty* =, Years 111 year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and conditions contained in the applicable Canadian Solar Limited Warranty Statement. Also this 25-year limited product warranty is available only for prod- ucts installed and operating on residential rooftops in certain regions. ................................................................................. MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system ISO 45001: 2018 / International standards for occupational health & safety PRODUCT CERTIFICATES* IEC 61215 / IEC 61730 / CE CEC listed (US California) / FSEC (US Florida) UL 61730 / IEC 61701 / IEC 62716 Take-e-way 4 01-U, ( E GO a R * The specific certificates applicable to different module types and markets will vary, and therefore not all of the certifications listed herein will simultaneously apply to the products you order or use. Please contact your local Canadian Solar sales representative to confirm the specific certificates available for your Product and applicable in the regions in which the products will be used. .................................................................................. CSI SOLAR (USA) CO., LTD. is committed to providing high quality solar photovoltaic modules, solar energy and battery storage solutions to customers. The company was recognized as the No.1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey. Over the past 20 years, it has successfully delivered over 70 GW of premium -quality solar modules across the world. ENGINEERING DRAWING (mm) Rear View Frame Cross Section A -A A -A 35 Mounting Hole CS6R-400MS-HL / I-V CURVES 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 A A v 5 10 15 20 25 30 35 40 45 50 5560 5 10 15 20 25 30 35 40 45 50 5560 ■ 1000 W/m' 5-C ■ ■ 800 W/m' 25°C ■ ■ 600 W/m' 45-C ■ ■ 400 W/m' 650C ■ ■ 200 W/m' ELECTRICAL DATA I STC* MECHANICAL DATA CS6R-380/385/390/395/400/405MS-HL Specification Data Nominal Max. Power (Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono -crystalline Opt. Operating Voltage (Vmp)30.0 V 30.2 V 30.4 V 30.6 V 30.8 V 31.0 V Cell Arrangement 108 [2 X (9 X 6) ] Opt. Operating Current (Imp) 12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A 1722 X 1134 X 35 mm Dimensions Open Circuit Voltage (Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V (67.8 X 44.6 X 1.38 in) Short Circuit Current (Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg (49.4 Ibs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti -ref - lective coating Operating Temperature -40°C - +85°C Frame Anodized aluminium alloy, Max. System Voltage 1000V (IEC/UQ J-Box IP68, 3 bypass diodes Module Fire Performance TYPE 2 (UL 61730 1000V) or CLASS C (IEC 61730) Cable 4 mm2 (IEC), 12 AWG (UL) Max. Series Fuse Rating 25 A Connector T6, MC4, MC4-EVO2 or MC4-EV02A Application Classification Class Cable Length 1550mm(61.0in) (+)/1100mm(43.3in) (-)* Power Tolerance 0 - + 10 W (Including Connector) * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell tempe- Per Pallet 30 pieces ratureof25°C. Per Container (40' HQ) 780 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. ELECTRICAL DATA I NMOT* TEMPERATURE CHARACTERISTICS CS6R-380/385/390/395/400/405MS-H L Nominal Max. Power (Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data Opt. Operating Voltage (Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficient (Pmax) -0.34 % / °C Opt. Operating Current (Imp) 10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient (Voc) -0.26 % / °C Open Circuit Voltage (Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient (Isc) 0.05 % / °C Short Circuit Current (Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Nominal Module Operating Temperature 42 ± 3°C * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m'•spectrum AM 1.5, ambient temperature 20oC, wind speed 1 m/s. PARTNER SECTION :.......................................................................... * The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on -going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. CSI SOLAR (USA) CO., LTD. 1350 Treat Blvd. Suite 500, Walnut Creek, CA 94598, USA I www.csisolar.com/na I service.ca@csisolar.com CSI SOLAR (USA) CO., LTD. Aug 2022 1 All rights reserved I PV Module Product Datasheet v1.1 C25_F23J1_NA solaredge.com SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014-2023 per articles 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Small, lightweight, and easy to install both outdoors or indoors Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) 12-25 YEAR WARRANTY SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT Rated AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA ACOutput Voltage Min.-Nom.-Max. (211 - 240 - 264) Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) ---Vac ACFrequency (Nominal)59.3 - 60 - 60.5 (1)Hz Maximum Continuous Output Current @240V 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V 16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 Vdc Maximum Input Current @240V(2)10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1)For other regional settings please contact SolarEdge support. (2)A higher current source may be used; the inverter will limit its input current to the values stated. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: June 19, 2023 DS-000153-NAM. Subject to change without notice. SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), wireless SolarEdge Home Network (optional)(3), Wi-Fi (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(4) Consumption Metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown -NEC 2014-2023 per articles 690.11 and 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14 (HI), CSA C22.3 No. 9 Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14 6 AWG 1'' Maximum / 14 4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1 2 strings / 14 6 AWG 1'' Maximum / 1 3 strings / 14 6 AWG Dimensions with Safety Switch (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(5) in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 44.9 / 20.4(5)lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(6) Protection Rating NEMA 4X (Inverter with Safety Switch) (3)For more information, refer to the SolarEdge Home Network datasheet (4)Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BEI4. For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box. (5) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4 will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (6)-rating information refer to the Temperature De-rating Technical Note for North America. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills. Power Optimizer For North America S440, S500 25 YEAR WARRANTY PV power optimization at the module level / Specifically designed to work with SolarEdge residential inverters / Detects abnormal PV connector behavior, preventing potential safety issues* / Module -level voltage shutdown for installer and firefighter safety / Superior efficiency (99.5%) / Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 v N m / Faster installations with simplified cable management and easy assembly using a single bolt / Flexible system design for maximum space utilization / Compatible with bifacial PV modules / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) solaredge.com solar=se / Power Optimizer For North America S440, S500 INPUT Rated Input DC Powers) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8-60 Vdc Maximum Short Circuit Current (Ise) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant ROHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm / in Weight (including cables) 655 / 1.5 gr / lb Input Connector MC412l Wire Length 0.1 / 0.32 m / ft -Input Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.S4, (-) 0.32 m / ft Operating Temperature Range") -40 to +85 C Protection Rating IP68 / Type66 Relative Humidity 0 -100 % (1) Rated power ofthe module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details S440,S500 1 8 1 14 1 18 Maximum String Length (Power Optimizers) l 25 50A Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Nhowea t.onnecieo rower per xrmg One String 7200W (Permitted only when the difference in connected power between Refer to Footnote 5 15,000W strings is 1,000W or less) Two strings or more 780OW Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safetyvoltage will be above the 30V requirement (5) If the inverters rated AC power s maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https.//www.solaredge.com/ sites/default/£ les/se-power-optimizer-single-string-design-application-note.pdf (6) It is not allowed to mix S-series and P-series Power Optimizers in new installations �. _ az - _ 135 © SolarEdge Technologies, Inc. All rights reserved. SODIREDGE, the SolarEdge logo, OPTIMIZED BY SODIREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February8, 2022 DS-000018-NA. Subject to change without notice. AM. RoHS Intertek Product specifications Eaton DG222URB Catalog Number: DG222URB Eaton General duty non-fusible safety switch, single-throw, 60 A, NEMA 3R, Rainproof, Painted galvanized steel, Two-pole, Two-wire, 240 V General specifications Eaton general duty non-fusible safety switch DG222URB 782113144238 7.38 in 14.38 in 8.69 in 9 lb Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. UL Listed WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Product Name Catalog Number UPC Product Length/Depth Product Height Product Width Product Weight Warranty Certifications Catalog Notes Eaton Corporation plc Eaton House 30 Pembroke Road Dublin 4, Ireland Eaton.com © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are property of their respective owners.Eaton.com/socialmedia Product specifications General duty safety switch Painted galvanized steel Non-fusible, single-throw Non-fusible 2 NEMA 3R 240V 60A Two-pole Resources Eaton's Volume 2—Commercial Distribution Double Up on Safety Switching Devices Flex Center Eaton Specification Sheet - DG222URB Selling Policy 25-000 - Distribution and Control Products and Services Product Category Enclosure material Type Fuse configuration Number of wires Enclosure Voltage rating Amperage Rating Number Of Poles Catalogs Multimedia Specifications and datasheets Warranty guides THE COMPLETE ROOF ATTACHMENT SOLUTION FEATURING TECHNOLOGY FLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac’s patented SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks. .LWWHGLQSDFNVIRUPD[LPXPFRQYHQLHQFHƜDVKLQJVDQGKDUGZDUHDUHDYDLODEOHLQ0LOORU'DUNƛQLVKHV With FLASHKIT pro, you have everything you need for a quick, professional installation. YOUR COMPLETE SOLUTION Flashings, lags, continuous slot L-Feet and hardware CONVENIENT 10 PACKS Packaged for speed and ease of handling FLASHKIT PRO 25 YEAR FULL-SYSTEM WARRANTY TRUSTED WATER SEAL FLASHINGS )25 48(67,216 25 &86720(5 6(59,&( 9,6,7 81,5$&&20 25 &$// FASTER INSTALLATION. 25-YEAR WARRANTY. FLASH.,7352,67+(&203/(7()/$6+,1*$1'$77$&+0(1762/87,21)25&20326,7,21522)6 )25 48(67,216 25 &86720(5 6(59,&( 9,6,7 81,5$&&20 25 &$// PRE-INSTALL • Locate roof rafters and snap chalk lines to mark the installation point for each roof attachment. • 'ULOODƌSLORWKROHDWHDFKURRIDWWDFKPHQW)LOOHDFKSLORWKROH with sealant. STEP 1 ,167$// FLASH.,7352)/$6+,1* • $GGD8VKDSHGEHDGRIURRIVHDODQWWRWKHXQGHUVLGHRIWKHƜDVKLQJ with the open side of the U pointing down the roof slope. Slide WKHDOXPLQXPƜDVKLQJXQGHUQHDWKWKHURZRIVKLQJOHVGLUHFWO\XS VORSHIURPWKHSLORWKROHDVVKRZQ$OLJQWKHLQGLFDWRUPDUNVRQWKH ORZHUHQGRIWKHƜDVKLQJZLWKWKHFKDONOLQHVRQWKHURRIWRFHQWHU WKHUDLVHGKROHLQWKHƜDVKLQJRYHUWKHSLORWKROHLQWKHURRI:KHQ LQVWDOOHGFRUUHFWO\WKHƜDVKLQJZLOOH[WHQGXQGHUWKHWZRFRXUVHVRI VKLQJOHVDERYHWKHSLORWKROH STEP 2 ,167$///)227 • )DVWHQ/IRRWDQG)ODVKLQJLQWRSODFHE\SDVVLQJWKHLQFOXGHGODJ EROWDQGSUHLQVWDOOHGVWDLQOHVVVWHHOEDFNHG(3'0ZDVKHUWKURXJK WKH/IRRW(3'0JURPPHWDQGWKHUDLVHGKROHLQWKHƜDVKLQJLQWR the pilot hole in the roof rafter. • 'ULYHWKHODJEROWGRZQXQWLOWKH/IRRWLVKHOGƛUPO\LQSODFH,WLV QRUPDOIRUWKH(3'0RQWKHXQGHUVLGHRIWKHVWDLQOHVVVWHHOEDFNHG (3'0ZDVKHUWRFRPSUHVVDQGH[SDQGEH\RQGWKHRXWVLGHHGJHRI the steel washer when the proper torque is applied. TIP: • 8VHFDXWLRQWRDYRLGRYHUWRUTXHLQJWKHODJEROWLIXVLQJDQLPSDFWGULYHU • 5HSHDW6WHSVDQGDWHDFKURRIDWWDFKPHQWSRLQW STEP 3 $77$&+/)227725$,/ • ,QVHUWWKHLQFOXGHG7EROWVLQWRWKHORZHUVORWRQWKH5DLO VROGVHSDUDWHO\VSDFLQJWKHEROWVWRPDWFKWKHVSDFLQJEHWZHHQ the roof attachments. • Position the Rail against the L-Foot and insert the threaded end of WKH7%ROWWKURXJKWKHFRQWLQXRXVVORWLQWKH/)RRW$SSO\DQWLVHL]H WREROWWKUHDGVWRSUHYHQWJDOOLQJRIWKH7EROWDQGLQFOXGHGƌ VHUUDWHGƜDQJHQXW3ODFHWKHƌƜDQJHQXWRQWKH7EROWDQG ƛQJHUWLJKWHQ5HSHDW67(3XQWLODOO/)HHWDUHVHFXUHGWRWKH5DLO ZLWKD7EROW$GMXVWWKHOHYHODQGKHLJKWRIWKH5DLODQGWRUTXHHDFK EROWWRIWOEV ,167$//FLASH.,7352)/$6+,1* STEP 1 STEP 2 STEP 3 ,167$///)227 $77$&+/)227725$,/ FLASHKIT PRO INSTALLATION GUIDE SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICEWith Superior Aesthetics CONCEALED UNIVERSAL CLAMPS W WITH UNIVERSAL MIDCLAMPIWITHTHUUNINEVESRSRSALALALMMIDICLCLAMP 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the ƛQDQFLDOVWUHQJWKWREDFNRXUSURGXFWVDQGUHGXFH\RXUULVN Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year OLPLWHGSURGXFWZDUUDQW\DQGD\HDUOLPLWHGƛQLVKZDUUDQW\ TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly VLPSOLƛHV\RXUSHUPLWWLQJDQGSURMHFWSODQQLQJSURFHVV CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO FHUWLƛFDWLRQVIRUDQG2+6$6 18001:2007, which means we deliver the highest standards IRUƛWIRUPDQGIXQFWLRQ7KHVHFHUWLƛFDWLRQVGHPRQVWUDWH RXUH[FHOOHQFHDQGFRPPLWPHQWWRƛUVWFODVVEXVLQHVVSUDFWLFHV UL2703 BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONLI S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 Project: 80082031 Date Issued: 2021-06-02 Issued To: Unirac 1411 Broadway NE Albuquerque, New Mexico, 87102 United States Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems - Certified to US Standards Models: SM - SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA - Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. Solarmount Certificate: 70131735 Project: 80082031 Master Contract: 266909 Date Issued: 2021-06-02 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, 10, 19, 22 or 25 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. UL 2703 Mechanical Load ratings: Downward Design Load (lb/ft²) 113.5 Upward Design Load (lb/ft²) 50.7 Down-Slope Load (lb/ft²) 16.13 Test Loads: Downward Load (lb/ft²) 170.20 Upward Load (lb/ft²) 76.07 Down-Slope Load (lb/ft²) 24.2 Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. AP P E N D I X H Te c h n i c a l D a t a S h e e t s Units in plf in ² SE C T I O N M O D U L U S ( X - A X I S ) in ³ SE C T I O N M O D U L U S ( Y - A X I S ) in ³ MO M E N T O F I N E R T I A ( X - A X I S ) in 4 MO M E N T O F I N E R T I A ( Y - A X I S ) in 4 RA D I U S O F G Y R A T I O N ( X - A X I S ) in RA D I U S O F G Y R A T I O N ( Y - A X I S ) in 0. 5 6 4 0 . 8 6 5 1 . 1 7 0. 1 5 0 . 3 6 3 0 . 8 9 8 0. 0 6 7 0 . 1 1 3 0 . 2 2 1 1. 2 7 1 CR O S S S E C T I O N A R E A 0. 4 0 9 0 . 6 2 5 1 . 0 5 9 BE A M H E I G H T 1. 7 0 2 . 5 7 3 . 0 0 AP P R O X W E I G H T 0. 4 9 1 0 . 7 2 8 0. 2 5 4 0 . 2 6 9 0 . 5 0 2 0. 1 3 0 . 4 6 7 1 . 4 5 0. 0 2 6 0 . 0 4 5 0 . 2 6 7 Properties SOLARMOUNT Light SOLARMOUNT Rail Profile 2 SOLARMOUNT HD PA G E H 3 TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458 E417M7! Engineering Alliance, Inc 11-December-2023 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87101 Tel: 505 242 6411 Attn.: Engineering Department https.11www. eng-alliance. com Subject: Engineering Certification for the Unirac SOLARMOUNT Flush Rail System to Support Photovoltaic Panels. The Unirac SOLARMOUNT Flush -to -Roof is an extruded aluminum rail system that is engineered to hold most framed solar modules to a roof structure and installed parallel to the roof. We have reviewed the SOLARMOUNT system, a proprietary mounting system constructed from modular parts which are intended for rooftop installation of solar photovoltaic (PV) panels; and have reviewed the U-Builder 2.0 Online tool. This U- Builder 2.0 software includes analysis for the SOLARMOUNT rails (SM LIGHT rail, SM STANDARD rail, and SM HEAVY DUTY rail) with Standard, Universal AF, and Pro Series hardware. All information, data, and analysis are in compliance with the following codes, city ordinances, and typical specifications: Codes: 1. 2015-2021 Washington State Building Code 2. ASCE/SEI 7-10 & 7-16 Minimum Design Loads for Buildings and Other Structures. 3. International Building Code, 2015 - 2021 Edition w/ Provisions from SEAOC PV-2 2017. 4. International Residential Code, 2015 - 2021 Edition w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. Aluminum Design Manual, 2015 & 2020 Edition. Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment: Shingle Roof: L-Foot, Flashkit Pro, Flashloc Comp, Flashloc Duo, Flashkit Pro SB Metal Roof: Standing Seam attachments, PM-9000S, PM Adjust Slotted Tile Roofs: Solar Hooks, Tile Replacement Attachment Spacing: Per U-Builder 2.0 Engineering report. Cantilever: The maximum cantilever length is L/3, where "L" is the span noted in the U-Builder 2.0 online tool. Clearance: 2" to 10" clear from top of roof to top of PV panel Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757, Email: sahmad@eng-alliance.com W=7 Engineering Alliance, Inc Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. https.11www. eng-alliance. com Landscape - PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the short side. Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE/SEI 7-10 & 7-16 Component and Cladding design. Notes: 1. U-Builder 2.0 Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems and do not include roof capacity check. 2. Risk Category II per ASCE 7-16. 3. Topographic factor, kzt is 1.0. 4. Array Edge Factor YE = 1.5 5. Average parapet height is 0.0 ft. 6. Wind speeds are LRFD values. 7. Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder 2.0 design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-Builder 2.0 software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder 2.0 Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder 2.0 software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder 2.0 engineering report and the manufacturer specifications are in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. Please feel free to call or email for any questions or clarifications. p� w. �y,.•' �Of •W �!u %; Prepared By: F - 01 Engineering Alliance, Inc Sugar Land, TX �0,`•,9�51947'0, ................ �E�� 11-DEC-2023 EXP.:15-DEC-2025 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757, Email: sahmad@eng-alliance.com