L.Brown Final - 105104891 HABITAT YELM - Peer SignedN
Vicinity Map
46.9483, -122.6103
Owner / Developer Contact Info
officeATTN:
SOUTH PUGET SOUND HABITAT FOR HUMANITY
910 5TH AVE SE
OLYMPIA, WA 98501
BEN FRANSUA 360-807-5890
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
GAS
PHONE
CABLE TV
514747586 105104891
N/A 101173178
N/A 108155306
N/A 105105514
N/A 593258097
N/A 583076795
N/A N/A
N/A N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Relocation
Removal
St. Light
Wire Transfer
UG XFMR
Distribution
Service Stubs
HP Svc/MSA
10.
9.
8.
7.
6.
5.
4.
3.
2.
1. THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH
PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES
SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE
STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR
VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4"
BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF
REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR
DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL
TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE.
ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH
INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED
TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY
CABLES PER THE CIRCUIT ONE-LINE DIAGRAM.
UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD
CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON
WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER
PUGET SOUND ENERGY STANDARDS.
AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN
CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE &
CONDUIT TABLE.
AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN
CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE &
CONDUIT TABLE.
AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER.
ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE.
AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3)
MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE.
(EXCAVATION: 3' SQ.)
AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS
INDICATED ON VAULT TABLE.
AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT.
AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF
STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO
EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE
STREET LIGHT STANDARDS. )
INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES
AND DATES.
POWER GENERAL NOTES - PLAT PROJECT
10
5
1
0
4
8
9
1
N
/
A
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
J.CALLAHAN 206.503.1520 02.21.24
A. DUNN 206.437.9150 02.21.24
N/A .N/A
C.DIAZ . 02.21.24
REDT # ( RW-133705 )YELM
HABITAT YELM DEVELOPMENT
1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS
P#22719230700, 407 LONGMIRE ST NW, YELM, WA 98597
PUGET SOUND ENERGY
N/A N/A
N/A 105104891
N/A 1 OF 3
THURSTON N/A N/A QSTHLE
19NW-T17N-R02E N/A N/A
1702E074 1702E116 1702E074 YEL-25
COMCAST
TED AXTELL
253.878.2794
LUMEN
DEWAYNE RICHERT
253.221.0133
RIGHT OF WAY
LINDA OLSON
425.462.3787
.
.
.
11.
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:JESSICA CALLAHAN
206.503.1520
JESSICA.CALLAHAN@PSE.COM
x
x
Standoff Bracket
15" Min Length
Conduit Clamp
Conduit Field Face
Quadrant
Climbing
SpaceRoad Face
Quadrant
Climbing
Space
5" Min
CL
LC
Direction of Vehicular Traffic
CONDUIT RISER PLACEMENT DETAIL
TOP VIEW
NOT TO SCALE
...
...
...
x x
BEN@SPSHABITAT.ORG
VAULT DETAIL @ V02
NOT TO SCALE
TOP VIEW
SIDE
VIEW
EXCAVATION:
4-2/3 CUBIC YARDS
Rock
Crushed
6"
3'-6"
2"
6'
6'
48"42"
36"
38"
42"
Struts
FRONT
FRON
T
TYPICAL NOTCH-OUT FOR TRANSFORMER,
NOT TO SCALE
& SECONDARY PEDESTAL/HANDHOLE
BACK OF EASEMENT
STANDARD
EASEMENT
LINE
ROW
10'
PL
1'
4' - 5'
Min.
1'
7'7'
TRANSFORMER
(WHEN PRESENT)
42"
45°42"
1'
45°
Pr
o
p
e
r
t
y
L
i
n
e
Road Side
Top View of Mainline Trench for
Single Stubout Location
4'
Pr
o
p
e
r
t
y
L
i
n
e
Road Side
Top View of Mainline Trench for Pedestal
or Double Stubout Location
42"45°
4'
45°
STUBOUT EXCAVATION DIMENSIONS
NOT TO SCALE
JOINT TRENCH DETAIL
NOT TO SCALE
MINIMUM CLEARANCES FOR PSE EQUIPMENT
NOT TO SCALE
OIL-FILLED EQUIPMENT
TRANSFORMER
APPROVED
AREA
CO
M
B
U
S
T
I
B
L
E
B
U
I
L
D
I
N
G
W
A
L
L
S
&
R
O
O
F
10'
10'
10'
COOLING
5' MIN
5' MIN
10' MIN
5'
MIN
FINS
ACCESS
CONCRETE PAD
MINIMUM CLEARANCES FOR PSE EQUIPMENT
NOT TO SCALE
CURB OR EDGE OF PAVEMENT
CURB OR EDGE OF PAVEMENT
5' MIN
ROAD OR
PARKING AREA
TYP. PAD
& TRANS-
FORMER
3'
MIN
3' MIN
DOOR
ACCESS
DOOR
REQUIRED
WORK SPACE
AREA
3' MIN
@ H1A, H1B & H2A
SHALL BE STAGGERED
CONNECTOR BARS
IN THE FRONT
NEUTRALS SHALL BE 18"
16"
13"
12"10"
2"
10"
Pedestal will accept up to six 3" conduits
SEALED WITH FOAM
CONDUIT SHALL BE
120 PVC CONDUIT ELBOWS
TYPICAL 24" RADIUS DB
SIDE VIEW WITH CONDUIT
10"
18"
16"
13"
10"
2"
36"
FRONT VIEW WITH CONDUIT
SECONDARY PEDESTAL DETAIL
NOT TO SCALE
JOINT TRENCH DETAIL
NOTES:
1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. *
If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. *
2. Rocks greater than 10 inches diameter are not permitted in the final backfill.
3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the
side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line.
4. Utilities shall not be stacked over the gas line in the trench.
5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements.
6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies.
* Alternatives to full-width trench shading require PSE approval.
Primary & Secondary-Mainline Gas & Communications (NTS)
ROAD SIDE
MINIPAD
MINIPAD
FIELD SIDE
VAULT
6" of crushed rock
(base for vault)
P/L
Power
Secondary
Power
Primary
Communications
42" Min
21"1'
Feeder
38"
2"
4" Sand Bedding
12" Sand
Cover
36"
Cover
4" Sand Bedding
42"
6" Additional depth when
Feeder is required
PSE 10' FRONTAGE EASEMENT
1'
TRANSFORMER
Final
Backfill
Initial
Backfill
Trench Depth
42" - 48"
ROAD SIDE
NATIVE
SECONDARY POWER
PEDESTAL
MATERIAL
P/L
Power
Secondary
Power
Primary
Conduit
Tel. & TV
Sand
6" or 12"
4" Sand Bedding
1'
36"
Cover
42"
12"
18"
Lower 2"
10"
Pedestal
PSE 10' FRONTAGE
EASEMENT
1'
Cover
Primary
Dirt Pile
Final Grade
24" Min
36"
Min Cover
Over Power
48"
Max
Depth
Final Backfill
4" Sand Bedding
Property Line
intercept (depth varies).
SidewalkCurb
Location of roof drain
48" Typical
Width may vary per
Number of Utilities
and Conduits
R/W or
Excavated
12" Typical
Power
Secondary
Power
TV & TEL
12" Min
4,5
1,2
3
6
6" or 12" Min Sand Shading
Over Power after Compaction1
VAULT DETAIL @ V01
NOT TO SCALE
EXCAVATION: _____ CUBIC YARDS
3'-6"
SIDE VIEW
2"
6"
CRUSHED
ROCK
TOP VIEW
7'
7'
6 1/3
SITE
4.29.24
R
O
A
D
A
17
8
7
6
22
20
3
18
9
LO
N
G
M
I
R
E
S
T
.
N
W
C
O
A
T
E
S
A
V
E
.
N
W
CU
L
L
E
N
S
S
T
.
N
W
T
R
U
M
P
A
V
E
.
N
W
16
15
5
21
4
11
19
10
2
1
14
13
12
T
R
U
M
P
P
L
.
N
W
FE
E
D
YEL
25
'404'
'108'
OPEN SPACE
TRACT 'C'
STORM
TRACT 'B'
RELOCATE
#2
A
C
S
R
B
Ø
'312'
'310'
'308'
'307'
#2
A
C
S
R
46'
R55'
FUSE @ 65T
SW#X91900
REPLACE
1" = 50'
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
J.CALLAHAN 206.503.1520 02.21.24
A. DUNN 206.437.9150 02.21.24
N/A .N/A
C.DIAZ . 02.21.24
REDT # ( RW-133705 )YELM
HABITAT YELM DEVELOPMENT
1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS
P#22719230700, 407 LONGMIRE ST NW, YELM, WA 98597
PUGET SOUND ENERGY
N/A N/A
N/A 105104891
1" = 50' 2 OF 3
THURSTON N/A N/A QSTHLE
19NW-T17N-R02E N/A N/A
1702E074 1702E116 1702E074 YEL-25
COMCAST
TED AXTELL
253.878.2794
LUMEN
DEWAYNE RICHERT
253.221.0133
RIGHT OF WAY
LINDA OLSON
425.462.3787
.
.
.
SITE PLAN
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
YEL-25
11.06.23
394 363 312
N/A 18 N/A
394 381 312
...
...
...
SCHED.SQ. FT.
MAX LRC =
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
Oil-Filled Equipment Clearances per PSE Std 0700.1500
If the oil-filled equipment is adjacent to… Clearance
Requirement
Combustible walls or roof (including stucco).10 FT
Noncombustible walls, soffits, and roofs (including brick, concrete,
steel and stone) providing the side of the transformer facing the wall
does not have doors. Materials that pass UBC Std. 2-1 or ASTM
E136-79 are considered to be noncombustible.
3 FT
Fire sprinkler valves, standpipes, and fire hydrants.6 FT
Doors, windows, vents, fire escapes, or other building openings.10 FT
The water's edge of a swimming pool or any body of water.15 FT
Individual domestic and irrigation wells. Clearance not required on
pole mounted transformers (pole placement still applies as stated in
6450.3000), TUT's installed in sealed vaults, 7200V single-phase
padmount transformers 50kva or less, and ones with reduced
flammability oil.
100 FT
Facilities used to dispense or store LP, hazardous liquids, or fuel.20 FT
Gas service meter relief vent.3 FT
Generators, customer-owned transformers, etc.6 FT
Developer Note:
The following Fault Current information MUST BE conveyed
to the builder of the units:
All units may require upgraded house electrical equipment as the
fault current at the meter base may exceed 10,000 amps.
FAULT CURRENT TABLE
1Ø PM TRANSFORMERS (240/120V)
120V WINDINGS 240V WINDINGS
LOCATION SIZE R/X
MIN.
%Z
FAULT
CURRENT
MIN.
%Z
FAULT
CURRENT
V01 75kVA 0.5 2.30
36,200 AMPS 1.80 23,100 AMPS
V02 50kVA 0.5 2.34
26,700 AMPS 1.80 17,400 AMPS
DEVELOPER TO PROVIDE TYPICAL 10' PSE
FRONTAGE EASEMENT FOR OPERATION
AND MAINTENANCE OF PSE EQUIPMENT.
EASEMENT TO BE CLEAR OF ALL BUILDING
OVERHANGS AND FOUNDATION FOOTINGS
10' CLEARANCE REQUIRED TO
TRANSFORMERS OR NON-FLAMMABLE
BUILDING MATERIALS REQUIRED
CIRCUIT FEET ADDED: 370'
17 2,543
115 AMPS
CROSSING CONDUIT TABLE
X-ING
#
LOCATION POWER
XING
LENGTH
ASBUILT
LOCATION
TYPE OF CROSSING
(Feeder, Primary, Secondary, etc.)FROM TO
SIZE
(IN)TYPE QTY
X1A LOT 1 LOT 22 2 DB120 1 75 ( )'WCL ST. LIGHT
X01 LOT 1 LOT 22 3 DB120 1 65 ( )'WCL SECONDARY
X02 LOT 3 LOT 21 3 DB120 2 65 ( )'WCL SECONDARY
X03 LOT 5 LOT 19 3 DB120 2 65 ( )'WCL SECONDARY
X04 LOT 7 LOT 17 3 DB120 1 65 ( )'WCL SECONDARY
X05 LOT 8 LOT 16 3 DB120 1 65 ( )'WCL SECONDARY
X06 LOT 10 LOT 15 3 DB120 1 65 ( )'WCL SECONDARY
2" DB120 GREY PVC = 75 FT 2" PVC PLUG /CAPS = 2
3" DB120 GREY PVC = 520 FT 3" PVC PLUG /CAPS = 16
PRIMARY CABLE & CONDUIT TABLE
LOCATION CONDUIT CABLE ASBUILT INFORMATION - FOREMAN COMPLETE
FROM TO
SIZE
(IN)QTY.
DESIGN
LENGTH
(FT)
BENDS PULL
(LBS)
PULL
REV
(LBS)
CABLE
SIZE
DESIGN
LENGTH
(FT)
PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED LUBRICANT (Gal.)
90° 45°22° 11°A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE EST. ACTUAL
P1A V01 2 1 75 1 1 - -39 94 1/0 AL JKT 110 -EJD779 --
V01 V02 2 1 300 - - 1 -107 86 1/0 AL JKT 315 -EJD880 --
2" PVC (FT) & BENDS =375 1 1 1 0 1/0 AL JKT TOTAL (FT) =425
VAULT & EQUIPMENT TABLE
SITE # GRID #
VAULT SIZE &
COVER
TYPE & SIZE
EQUIPMENT IN
VAULT
PRIMARY
BUSHINGS TRANSFORMER ID NUMBERS
(COMPANY ID)
AS-BUILT INFORMATION
LB DC FOREMAN: INCLUDE PHASE TAPPED
V01 559593
147325
54"x54"x38"
Unistrut HH
Matid: 7663002
75KVA MP TRF
120/240
Matid: 6247150
2 -
MINU1LL 6045.1010 BØ
V02 559613
147302
42"x48"x38"
Unistrut HH
Matid: 7663001
50KVA MP TRF
120/240
Matid: 6247100
1 1
MINU1SR 6045.1010 BØ
SECONDARY CABLE & CONDUIT TABLE
LOCATION
CABLE CONDUIT VOLTAGE ASBUILT INFORMATION
SIZE LENGTH ASSUMED SIZE LENGTH BENDS DROP FLICKER
Foreman - Complete
FROM TO
(1/O,4/O,350)Design (ft)Lot Corner to
Meter (ft)(in) Design (ft)90° 45°22° 11°
(Percent) (Percent)Actual Amount Installed Cable Conduit
V01 H1A 350 65 -3 65 1 - - -
2.6 1.2
V01 H1B 350 115 -3 115 1 - - -
3.1 1.5
V01 LOT 1 1/O 40 50 3 40 1 - - -
3.0 2.4
V01 LOT 2 1/O 15 50 3 15 1 - - -
2.7 2.0
V01 LOT 22 1/O 70 50 3 5 1 - - -
3.3 2.8
H1A LOT 3 1/O -50 3 -- - - -
3.2 2.1
H1A LOT 4 1/O -50 3 -- - - -
3.2 2.1
H1A LOT 19 4/O 105 50 3 40 2 - - -
3.9 3.1
H1A LOT 20 1/O 80 50 3 15 2 - - -
4.2 3.5
H1A LOT 21 1/O 75 50 3 10 2 - - -
4.2 3.5
H1B LOT 5 1/O -50 3 -- - - -
3.7 2.4
H1B LOT 6 1/O -50 3 -- - - -
3.7 2.4
H1B LOT 7 1/O 50 50 3 50 1 - - -
4.5 3.5
H1B LOT 17 4/O 100 50 3 35 2 - - -
4.4 3.5
H1B LOT 18 1/O 75 50 3 10 2 - - -
4.7 3.8
V02 H2A 350 110 -3 110 1 - - -
3.4 2.0
V02 LOT 11 1/O 60 50 3 60 1 -1 -3.7 3.2
V02 LOT 12 1/O 55 50 3 55 1 -1 -3.6 3.1
V02 LOT 13 1/O 10 50 3 10 1 - - -
3.0 2.3
V02 LOT 14 1/O 10 50 3 10 1 - - -
3.0 2.3
H2A LOT 8 4/O 55 50 3 55 1 - - -
4.4 3.4
H2A LOT 9 1/O -50 3 -- - - -
4.1 2.9
H2A LOT 10 1/O -50 3 -- - - -
4.1 2.9
H2A LOT 15 4/O 70 50 3 5 2 - - -
4.5 3.5
H2A LOT 16 4/O 90 50 3 25 2 - - -
4.7 3.7
1/O UG Triplex (ft) =540 3" PVC & BENDS (ft)=730 26 0 2 0 2.7
4/O UG Triplex (ft) =420
350 UG Triplex (ft) =290 TOTAL QTS OF GLUE 2.7
SITE SPECIFIC NOTES
At P01 (559585-147325) 1976 CLASS 3 - 40'
-TO BE RELOCATED OUT OF PROPOSED ROAD
-REMOVE 25kVA XFMR
APPROXIMATELY 7' WEST AND 10' NORTH TO PROPOSED PLANTER
At P1A
-INSTALL NEW 50' CL 3 POLE (PD503) 6010.1000
-INSTALL 1Ø PRI NEUT DE #2ACSR (DE2115A) 6031.3011
-APPROXIMATELY 7' WEST AND 10' NORTH TO PROPOSED PLANTER
-INSTALL 1Ø TERM UG TO OH FEED W/ LOAD INTERRUPTER C/O (UTSU1L1) 6043.1001
- FUSE AT 65T (3412600)
- ALUM "H" CONNECTOR (2167000)
-INSTALL SW#X91900
-NEUTRAL TO BE ROLLED TO PRIMARY POSITION FOR ST. LIGHT CLEARANCE
-INSTALL 10" SINGLE HELIX 1" ROD (ANDH1) 6012.1000 (L = 15'E)
-INSTALL 7/16" PRI DG (GYD7SA) TO NEW ANCHOR 6013.0100 (E)
-INSTALL GRID# 559593-147325
-REMOVE POLE AND ALL PSE EQUIPMENT
PER PROJECT CONTACT BEN FRANSUA
NO EV CHARGING TO BE INSTALLED ON
HABITAT YELM DEVELOPMENT
At P02 (559571-147314) 1978 CLASS 3 - 40'
-EXISTING POLE TO BE RELACED TO MEET ST. LIGHT CLEARANCE
-INSTALL 3" SECONDARY RISER (RIS3CSS) ON NEW STANDOFF BRACKETS 6042.1000
-APPROXIMATELY 4' SOUTH AND 2' WEST OF EX. POLE LOCATION
-TRANSFER 50kVA TRANSFORMER TO NEW POLE
-INSTALL NEW 45' CL 3 POLE (PD453) 6010.1000
-INSTALL 2" PRIMARY RISER (RIS2CSS) ON NEW STANDOFF BRACKETS 6042.1000
RETIREMENT POLE TABLE
SITE
#
POLE DATA POLE TRANSFERS REMARKS
GRID #HEIGHT CLASS YEAR
XFMR CO.
ID#TOPPED RMVD TEL TV FIBER ST. LIGHT
(ADDITIONAL INFORMATION)
P01 559585-147325 40' 3 1976 COMCAST
P02 559571-147314 40' 3 1978 YCOM / FAIRPOINT COMMUNICATIONS / COMCAST
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P1A 559585-147325 50 3 2024
PSE Equip #
P02 559571-147314 45 3 2024
PSE Equip #
DEDICATED FACILITIES
SITE SPAN ADDITIONAL REMARKS LABOR UNITS
# FROM TO FOOTAGE
-V01 LOT 1 30 DED. CONDUIT & WIRE 2-36, 2-54A
- H1B LOT 7 50 DED. CONDUIT & WIRE 2-36, 2-54A
- H2A LOT 8 50 DED. CONDUIT & WIRE 2-36, 2-54A
V02 LOT 12 45 DED. CONDUIT & WIRE 2-36, 2-54A
TOTAL FT= 175
-TRANSFER EXISTING SERVICES TO NEW POLE
-EXISTING GRID# TO REMAIN
-INSTALL NEW 37.5kVA OH XFMR (TRFPXF) 6025.1000
New pole at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER TRANSFER
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P02
559571-147315
50kVA
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
P1A
559593-147325
37.5kVA
TRFPXF
NEW @ 404:
%V DROP: 3.2
% FLICKER: 7.3
EXISTING @ 404:
% V. DROP: 3.7
% FLICKER: 7.5
NEW @ 108:
%V DROP: 1.5
% FLICKER: 3.2
EXISTING @ 108:
% V. DROP: 2.0
% FLICKER: 3.5
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P01
559585-147325
25kVA
-TRANSFER EXISTING OH SERVICES TO P1A
4.29.24
R
O
A
D
A
17
8
7
6
22
20
3
18
9
16
15 5
21
4
11
19
10
2
1
14
13
12
OPEN SPACE
TRACT 'C'
FE
E
D
YEL
25
B
Ø
#2
A
C
S
R
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
J.CALLAHAN 206.503.1520 02.21.24
A. DUNN 206.437.9150 02.21.24
N/A .N/A
C.DIAZ . 02.21.24
REDT # ( RW-133705 )YELM
HABITAT YELM DEVELOPMENT
1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS
P#22719230700, 407 LONGMIRE ST NW, YELM, WA 98597
PUGET SOUND ENERGY
N/A N/A
N/A 105104891
AS SHOWN 3 OF 3
THURSTON N/A N/A QSTHLE
19NW-T17N-R02E N/A N/A
1702E074 1702E116 1702E074 YEL-25
COMCAST
TED AXTELL
253.878.2794
LUMEN
DEWAYNE RICHERT
253.221.0133
RIGHT OF WAY
LINDA OLSON
425.462.3787
.
.
.
...
...
...
EX OVERHEAD CIRCUIT MAP 1702E116
SCALE: 6" = 1 MILE
NEW PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAM
NOT TO SCALE
EX UNDERGROUND CIRCUIT MAP 1702E074
SCALE: 1" = 100'
SITE
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
SITE
NOT TO SCALE
NEW CONDUIT DIAGRAM
NEW 1/O AL
EJD880-BØ
NEW 1/O AL
EJD779-BØ
SL #6 CIC
PRIMARY 2"
SECONDARY 3"
CONDUIT LEGEND
SCALE: NONE
STREET LIGHT TUBE DETAIL
Plan View Detail
of Street Light Tube
Wire Entrance
Slot
Street Light
Tube
Field
Side
Road
Side
Wire
Entrance Slot
45°
45°
Position 3" x 6" wire entrance slot 45 degrees
left or right from a line perpendicular to road-
way through center of tube.
Field Side
3" x 6" Wire
Entrance Slot
45°
45°
Street light tube
set 2" below grade.
Road Side
18" - 24" Minimum
Depending on
Pole Type
5'-0"
20"
26"
1. ALL STREET LIGHTING POLES ARE TO BE INSTALLED PER
STANDARD 6375.4800 (page #2) IN THE "LINE WORK PRACTICES
MANUAL".
2. ALL POLES (WOOD, CONCRETE OR FIBERGLASS) ARE TO BE SET
PLUMB AND EMBEDDED TO THE GROUND LINE MARKED ON THE
POLE.
3. BACKFILL AROUND POLE WITH 5/8" MINUS GRAVEL AND COMPACT
IN 6" LIFTS. (PEA GRAVEL AND NATIVE SOILS ARE NOT
ACCEPTABLE.) APPROXIMATELY 1 CU. YD. OF 5/8" MINUS
CRUSHED ROCK WILL BE REQUIRED.
4. IN ALL SHOEBOX AND COBRAHEAD INSTALLATIONS, THE
LUMINAIRE MUST BE LEVELED.
STREET LIGHT NOTES
POTELCO:
1. THE DEVELOPER IS REQUIRED TO SUPPLY AND INSTALL PLASTIC
(NON PAPER) STREET LIGHT TUBES (MINIMUM 18" DIAMETER) TO
AID IN THE INSTALLATION OF THE STREET LIGHTING POLES.
2. DEVELOPER MUST SUPPLY DURABLE LID/COVER AT EACH STREET
LIGHT TUBE.
3. DEVELOPER TO PROVIDE ALL TRENCHING AND CONDUIT WITH
PULL-STRINGS FOR STREET LIGHTING CIRCUITRY.
4. CONDUIT SHALL BE SCH 40 PVC, CONDUIT CROSSING ROADWAYS
OR DRIVEWAYS SHALL BE SCH 80 PVC.
DEVELOPER/CUSTOMER:
STREET LIGHT CIRCUITRY TABLE - 105105514
SITE
# FROM
CABLE INFO AS-BUILT
REMARKSTYPE LF TYPE LENGTH
SL1 V01 #6 CIC 115 - BY INTOLIGHT
SL2 V02 #6 CIC 105 - BY INTOLIGHT
TOTAL FT =220 TOTAL FT =
SECONDARY HH/PEDESTAL TABLE
Site
Pedestal
or
Handhole
Number of
Positions
Required
Remarks
H1A PEDESTAL 6 - SEPL6 6050.1000
H1B PEDESTAL 6 - SEPL6 6050.1000
H2A PEDESTAL 6 - SEPL6 6050.1000
STREET LIGHT TABLE
SITE
#
POLE LUMINAIRE TUBE POLE BASE TYPE
(Direct Buried or
Basemount)
WO #BILLING
SCH.
SMART STREET
LIGHT NODE
TOTAL
CONN LOADGRID # TAG #TYPE MTG HT. ARM WATTS STYLE
TUBE
LENGTH
TUBE
DIAMETER
SL1 559609
147295 GRN CONCRETE 30' 8'71W LED CHFL 3K T3 5'18"DIRECT BURIED 105105515 51 120/240
SL2 559585
147325 GRN CONCRETE 30' 8'71W LED CHFL 3K T3 5'18"DIRECT BURIED 105105515 51 120/240
4.29.24