Fire Underground Drawings-Tahoma Terra Storage ProjectFIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
6" FLANGE TO 1'-0" AFF
F.D.C. LINE
6" FLANGE TO 1'-0" AFF
BLDG 'B'
BLDG 'A'
BLDG 'C'BLDG 'D'BLDG 'H'BLDG 'J'
BLDG 'L'BLDG 'K'
BLDG 'G'
BLDG 'F'
BLDG 'E'
BL
D
G
'
M
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
RISER ROOM
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
F
A
C
I
L
I
T
Y
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
OVERALL SITE PLAN
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 50'-0"
PROJECT
NORTH
OVERALL SITE PLAN
0 100'50'25'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.0
BW
/
J
G
F
PROJECT INFORMATION:
COMMERCIAL SELF-STORAGE FACILITY WITH 12 BUILDINGS.
BUILDINGS A, B, C, D, H, J, K, L ARE FULLY SPRINKLERED
BUILDINGS E, F, G, M ARE NON-SPRINKLERED.
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
FLOW TEST INFORMATION
04/30/2024
1'-6"
2'
1'
1.
5
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGES TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
11
+
0
0
10+00
11+00
13+00 12+00
1
4
+
0
0
P
I
1
0
+
4
5
.
0
1
P
I
1
1
+
1
4
.
4
1
PI
1
3
+
2
9
.
5
7
C/L INT
10+00.00 (E) =
11+03.20 (W)
C/L INT
10+00.00 (W)=
TAHOMA BLVD =
N 593867.32
E 1109087.59
BLDG 'A'
A
B
C
VERTICAL DATUM MERIDIAN HORIZONTAL DATUM
NGVD 29 PER T.C.H.P.N. #1252BM
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
YELM HIGHWAY AND KILLION ROAD
ELEVATION = 246.39 (NGVD)
DATUM DATUM
PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER
AUDITOR'S FILE NO. 4620459
0
SCALE: 1" = 30'
30 15 30 60
HAT
T
O
N
GOD
A
T
PAN
T
I
E
R
MAT
C
H
L
I
N
E
14+
0
0
.
0
0
COFFEE
SHOP
RETAIL
STORAGE
OFFICE
MAINTAIN 42" MINIMUM COVER OVER WATERMAIN FROM FINISH GRADE
T
A
H
O
M
A
B
L
V
D
S
E
LONG
M
I
R
E
S
T
S
E
SEE
S
H
E
E
T
2
6
30
'
I
N
G
R
E
S
S
,
E
G
R
E
S
S
A
N
D
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
1
0
'
M
I
N
.
10'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
EXISTING FIRE
HYDRANT (TYP)
SE
E
S
H
E
E
T
2
7
36 LF 8" PVC
WATER
11+74.72, 2.50' RT (W)
INSTALL
1 - 8"x4" TEE (MJxFL)
1 - 4" GV (FLxMJ)
31 LF 4" D.I. PIPE
BLOCKING
11+05.64, 6.22' RT (W)=
10+06.49, 1.59' RT (E)
INSTALL
1 - 8" TEE (FL)
1 - 8" ADAPTER (FLxMJ)
1 - 8" GV (FLxMJ)
1 - 8" GV (FL)
1 - 8" 22-1/2° BEND (FL)
1 - 8" 11-1/4° BEND (FLxMJ)
BLOCKING18 LF 8" PVC
WATER
52 LF 8" PVC
WATER
TA
H
O
M
A
B
L
V
D
.
EA
S
T
WE
S
T
NORTH
NE
KEY MAP
N.T.S.
LO
N
G
M
I
R
E
7 LF 8" PVC
WATER
11+74.72, 31.39' LT (W)
INSTALL
1 - 4" GV
w/ POST INDICATOR
BLOCKING
FIRE SPRINKLER LINE DCDA
INSIDE BUILDING
(SEE MECHANICAL PLANS, TYP)
11+92.97, 16.83' LT (W)
INSTALL
1 - FDC
(CONTRACTOR TO CLEARLY
LABEL BLDG ADDRESS)
12+52.23, 18.00' LT (W)
INSTALL
1 - 5/8" WATER METER
(RETAIL BLDG)
1 - RPBA
12+27.55, 39.00' RT (W)
INSTALL
1 - 1-1/2" WATER METER
(COFFEE SHOP)
1 - RPBA
11+31.91, 41.46' LT (W)
INSTALL
1 - 5/8" WATER METER
(STORAGE OFFICE)
1 - RPBA
170 LF 8" PVC
WATER
APPROXIMATE LOCATION OF
EXISTING 10" WATERMAIN
EXISTING 10" WATER STUB
12+53.22, 26.00' LT (W)
INSTALL
1 - 5/8" WATER IRRIGATION
w/ DCVA/BACKFLOW PREVENTER
TO BE INSTALLED BY LANDSCAPE
CONTRACTOR
(SEE LANDSCAPE PLAN)
10+73.97, 17.00' LT (W)
INSTALL
1 - 5/8" WATER IRRIGATION
w/ DCVA/BACKFLOW PREVENTER
TO BE INSTALLED BY LANDSCAPE
CONTRACTOR
(SEE LANDSCAPE PLAN)
4" SCH 40 CONDUIT W/ TRACER WIRE
FOR IRRIGATION CROSSING (TYP)
117 LF 8" PVC
WATER
13+34.58, 79.00' LT (W)
INSTALL
1 - HYDT ASSEMBLY
(STD DRAWING 4-7)
BLOCKING
EX
I
T
1.
2
7
'
2'
1.5'
8.17'
16
.
6
'
104 LF 4" DI FDC LINE
FROM BLDG A RISER
ROOM TO FDC
N 594055.33 E 1108785.12
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY
LABEL "BLDG B")
13+09.33, 2.50' RT (W)
INSTALL 1 - 8"x4" TEE
(MJ) 17 LF 4" D.I.
FIRELINE TO BLDG A
BLOCKING
N 594066.15 E 1108773.31
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO
CLEARLY LABEL "BLDG A")
BLDG 'B'
DCDA LOCATED
INSIDE BUILDING
SEE FIRE
PROTECTION PLANS
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
13+34.58, 51.81' LT (W)
INSTALL 1 - 8"x4" TEE (MJ)
1- 4" 45 DEG ELL (MJ)
37 LF 4" D.I. FIRELINE TO
BLDG B BLOCKING
8" WATER MAIN 8" WATER MAIN
8
"
W
A
T
E
R
M
A
I
N
8" W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
11+78.95, 2.50' RT (W)
INSTALL
1- 8"x6" TEE (MJxFL)
1- 6" GV (FLxRMJ)
(STD DWG 4-11)
1-HYDT ASSEMBLY
(STD DWG 4-7)
(11+78.95, 18.50'RT)
BLOCKING
10+69.51, 5.50' RT
(W) REMOVE EXISTING CAP &
BLOWOFF INSTALL
1 - 10"x8" REDUCER
CONTRACTOR TO FIELD VERIFY
BLOCKING LOCATION, DEPTH, SIZE &
FITTINGS REQUIRED PRIOR TO
CONSTRUCTION.
11+24.96, 2.50' RT (W)
INSTALL
1 - 8" 11-1/4° BEND (MJ)
BLOCKING
(STD DWG 4-13)
13+28.57, 2.50' RT (W) INSTALL
1 - 8" 45° BEND (MJxFL)
1 - 8" TEE (FL) 1 - 8" ADAPTER
(FLxMJ) BLOCKING
55 LF 8" PVC
WATER
26 LF 8" PVC
WATER
1'-6"
2'
1
'
1.
5
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGES TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'A'
A COFFEE
SHOP
8" WATER MAIN
8
"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
A
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "A"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "A" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "A" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
VICINITY MAP
N.T.S.
FLOW TEST INFORMATION
04/30/2024
1'-6"
2'
1'
1.
5
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGES TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
11
+
0
0
10+00
11+00
13+00 12+00
1
4
+
0
0
P
I
1
0
+
4
5
.
0
1
P
I
1
1
+
1
4
.
4
1
PI
1
3
+
2
9
.
5
7
C/L INT
10+00.00 (E) =
11+03.20 (W)
C/L INT
10+00.00 (W)=
TAHOMA BLVD =
N 593867.32
E 1109087.59
BLDG 'A'
A
B
C
VERTICAL DATUM MERIDIAN HORIZONTAL DATUM
NGVD 29 PER T.C.H.P.N. #1252BM
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
YELM HIGHWAY AND KILLION ROAD
ELEVATION = 246.39 (NGVD)
DATUM DATUM
PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER
AUDITOR'S FILE NO. 4620459
0
SCALE: 1" = 30'
30 15 30 60
HAT
T
O
N
GOD
A
T
PAN
T
I
E
R
MAT
C
H
L
I
N
E
14+
0
0
.
0
0
COFFEE
SHOP
RETAIL
STORAGE
OFFICE
MAINTAIN 42" MINIMUM COVER OVER WATERMAIN FROM FINISH GRADE
T
A
H
O
M
A
B
L
V
D
S
E
LONG
M
I
R
E
S
T
S
E
SEE
S
H
E
E
T
2
6
30
'
I
N
G
R
E
S
S
,
E
G
R
E
S
S
A
N
D
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
1
0
'
M
I
N
.
10'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
EXISTING FIRE
HYDRANT (TYP)
SE
E
S
H
E
E
T
2
7
36 LF 8" PVC
WATER
11+74.72, 2.50' RT (W)
INSTALL
1 - 8"x4" TEE (MJxFL)
1 - 4" GV (FLxMJ)
31 LF 4" D.I. PIPE
BLOCKING
11+05.64, 6.22' RT (W)=
10+06.49, 1.59' RT (E)
INSTALL
1 - 8" TEE (FL)
1 - 8" ADAPTER (FLxMJ)
1 - 8" GV (FLxMJ)
1 - 8" GV (FL)
1 - 8" 22-1/2° BEND (FL)
1 - 8" 11-1/4° BEND (FLxMJ)
BLOCKING18 LF 8" PVC
WATER
52 LF 8" PVC
WATER
TA
H
O
M
A
B
L
V
D
.
EA
S
T
WE
S
T
NORTH
NE
KEY MAP
N.T.S.
LO
N
G
M
I
R
E
7 LF 8" PVC
WATER
11+74.72, 31.39' LT (W)
INSTALL
1 - 4" GV
w/ POST INDICATOR
BLOCKING
FIRE SPRINKLER LINE DCDA
INSIDE BUILDING
(SEE MECHANICAL PLANS, TYP)
11+92.97, 16.83' LT (W)
INSTALL
1 - FDC
(CONTRACTOR TO CLEARLY
LABEL BLDG ADDRESS)
12+52.23, 18.00' LT (W)
INSTALL
1 - 5/8" WATER METER
(RETAIL BLDG)
1 - RPBA
12+27.55, 39.00' RT (W)
INSTALL
1 - 1-1/2" WATER METER
(COFFEE SHOP)
1 - RPBA
11+31.91, 41.46' LT (W)
INSTALL
1 - 5/8" WATER METER
(STORAGE OFFICE)
1 - RPBA
170 LF 8" PVC
WATER
APPROXIMATE LOCATION OF
EXISTING 10" WATERMAIN
EXISTING 10" WATER STUB
12+53.22, 26.00' LT (W)
INSTALL
1 - 5/8" WATER IRRIGATION
w/ DCVA/BACKFLOW PREVENTER
TO BE INSTALLED BY LANDSCAPE
CONTRACTOR
(SEE LANDSCAPE PLAN)
10+73.97, 17.00' LT (W)
INSTALL
1 - 5/8" WATER IRRIGATION
w/ DCVA/BACKFLOW PREVENTER
TO BE INSTALLED BY LANDSCAPE
CONTRACTOR
(SEE LANDSCAPE PLAN)
4" SCH 40 CONDUIT W/ TRACER WIRE
FOR IRRIGATION CROSSING (TYP)
117 LF 8" PVC
WATER
13+34.58, 79.00' LT (W)
INSTALL
1 - HYDT ASSEMBLY
(STD DRAWING 4-7)
BLOCKING
EX
I
T
1.
2
7
'
2'
1.5'
8.17'
16
.
6
'
104 LF 4" DI FDC LINE
FROM BLDG A RISER
ROOM TO FDC
N 594055.33 E 1108785.12
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY
LABEL "BLDG B")
13+09.33, 2.50' RT (W)
INSTALL 1 - 8"x4" TEE
(MJ) 17 LF 4" D.I.
FIRELINE TO BLDG A
BLOCKING
N 594066.15 E 1108773.31
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO
CLEARLY LABEL "BLDG A")
BLDG 'B'
DCDA LOCATED
INSIDE BUILDING
SEE FIRE
PROTECTION PLANS
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
13+34.58, 51.81' LT (W)
INSTALL 1 - 8"x4" TEE (MJ)
1- 4" 45 DEG ELL (MJ)
37 LF 4" D.I. FIRELINE TO
BLDG B BLOCKING
8" WATER MAIN 8" WATER MAIN
8
"
W
A
T
E
R
M
A
I
N
8" W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
11+78.95, 2.50' RT (W)
INSTALL
1- 8"x6" TEE (MJxFL)
1- 6" GV (FLxRMJ)
(STD DWG 4-11)
1-HYDT ASSEMBLY
(STD DWG 4-7)
(11+78.95, 18.50'RT)
BLOCKING
10+69.51, 5.50' RT
(W) REMOVE EXISTING CAP &
BLOWOFF INSTALL
1 - 10"x8" REDUCER
CONTRACTOR TO FIELD VERIFY
BLOCKING LOCATION, DEPTH, SIZE &
FITTINGS REQUIRED PRIOR TO
CONSTRUCTION.
11+24.96, 2.50' RT (W)
INSTALL
1 - 8" 11-1/4° BEND (MJ)
BLOCKING
(STD DWG 4-13)
13+28.57, 2.50' RT (W) INSTALL
1 - 8" 45° BEND (MJxFL)
1 - 8" TEE (FL) 1 - 8" ADAPTER
(FLxMJ) BLOCKING
55 LF 8" PVC
WATER
26 LF 8" PVC
WATER
B
EX
I
T
1.
2
7
'
2'
1.5'
8.17'
16
.
6
'
BLDG 'B'
DCDA LOCATED
INSIDE BUILDING
SEE FIRE
PROTECTION PLANS
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
B
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "B"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "B" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "B" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
F.D.C. BUILDING 'B'
F.D.C. BUILDING 'A'
FIRE HYDRANT
VICINITY MAP
N.T.S.
04/30/2024
14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00
D
E
K
H
G
J
L
C
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
TOPOGRAPHIC NOTE:
THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS
HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION
FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO
BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT
RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR
ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED
INTO THESE DRAWINGS AS A RESULT.
MA
T
C
H
L
I
N
E
14
+
0
0
.
0
0
SE
E
S
H
E
E
T
2
5
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
170 LF 8" PVC
WATER
198 LF 8" PVC
WATER
239 LF 8" PVC
WATER
TA
H
O
M
A
B
L
V
D
.
EA
S
T
WE
S
T
NORTH
NE
KEY MAP
N.T.S.
LO
N
G
M
I
R
E
84 LF 8" PVC
WATER
61 LF 8" PVC WATER
19+79.22, 132.65' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(19+79.22, 142.65' LT)
BLOCKING
17+39.24, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(17+39.24, 109.00' LT)
BLOCKING
15+41.22, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(15+41.22, 109.00' LT)
BLOCKING
50 LF 8" PVC WATER
18 LF 8" PVC
WATER
15+41.22, 59.58' LT (W)
INSTALL 1 - 8"x4" TEE(MJ)
23 LF 4" D.I.
FIRELINE TO BLDG D
BLOCKING
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
19 LF 8" PVC
WATER MAIN
65 LF 4" DI FDC LINE FROM
BLDG C RISER ROOM TO
FDC
15+29.23, 109.00' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY
LABEL "BLDG C")
15+53.22, 109.00' LT INSTALL
1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO
CLEARLY LABEL "BLDG D)
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
15+41.22, 42.00' LT (W)
NSTALL 1 - 8"x4" TEE (MJ)
27 LF 4" D.I. FIRELINE TO
BLDG C BLOCKING
117 LF 8" PVC
WATER
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
24 LF 4" DI FIRELINE FROM BLDG K
RISER ROOM TO FDC
18+47.90, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG K")
18+64.93, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG L")
24 LF 4" DI FIRELINE FROM BLDG L
RISER ROOM TO FDC
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
34 LF 8" PVC
WATER
123 LF 8" PVC
WATER
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
68 LF 4" DI FIRELINE FROM
BLDG H RISER ROOM TO FDC
70 LF 4" DI FIRELINE FROM
BLDG J RISER ROOM TO FDC
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
17+39.33, 2.50' RT (W)
INSTALL
1-8" TEE (FL)
2- 8" GV (FLxMJ)
1 -8" ADAPTER
18+56.43, 36.00' RT (W) INSTALL
1 - 8"x4" CROSS (FLxMJ)
24LF 4" D.I. FIRELINE TO BLDG K
24LF 4" D.I. FIRELINE TO BLDG L
1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ)
1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY
(STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING
19+79.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
15+41.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
19+79.22, 82.00' LT (W) INSTALL
1 - 8"x4" CROSS (MJ)
25LF 4" D.I. FIRELINE TO BLDG H
25LF 4" D.I. FIRELINE TO BLDG J
BLOCKING
15+00.52, 2.50' RT (W)
INSTALL 1 - 8"x6" TEE (FL)
1 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
1 - 6" GV (FLxRMJ)
41LF 6" D.I. PIPE
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(15+00.52, 43.97'RT)
BLOCKING
18+56.43, 2.50' RT (W)
INSTALL 1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
BLDG 'C'BLDG 'D'
BLDG 'H'BLDG 'J'
BLDG 'K'BLDG 'L'
EX
I
T
2'
1.
4
8
'
1.5'
8.17'
16
.
7
9
'
10
'
EX
I
T
2'
1.
5
'
1.5'
8.17'
34
.
3
1
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
48 LF 4" DI FIRELINE FROM
BLDG D RISER ROOM TO
FDC
41 LF 8" PVC
WATER
19+72.22, 141.48' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG H")
19+86.22, 143.82' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG J")
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'F'BLDG 'G'
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
C
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
BLDG 'C'
EX
I
T
2'
1.
4
8
'
1.5'
8.17'
16
.
7
9
'
10
'
EX
I
T
2'
1.
5
'
1.5'
8.17'
34
.
3
1
'
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
C
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "C"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "C" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "C" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
VICINITY MAP
N.T.S.
04/30/2024
14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00
D
E
K
H
G
J
L
C
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
TOPOGRAPHIC NOTE:
THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS
HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION
FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO
BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT
RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR
ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED
INTO THESE DRAWINGS AS A RESULT.
MA
T
C
H
L
I
N
E
14
+
0
0
.
0
0
SE
E
S
H
E
E
T
2
5
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
170 LF 8" PVC
WATER
198 LF 8" PVC
WATER
239 LF 8" PVC
WATER
TA
H
O
M
A
B
L
V
D
.
EA
S
T
WE
S
T
NORTH
NE
KEY MAP
N.T.S.
LO
N
G
M
I
R
E
84 LF 8" PVC
WATER
61 LF 8" PVC WATER
19+79.22, 132.65' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(19+79.22, 142.65' LT)
BLOCKING
17+39.24, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(17+39.24, 109.00' LT)
BLOCKING
15+41.22, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(15+41.22, 109.00' LT)
BLOCKING
50 LF 8" PVC WATER
18 LF 8" PVC
WATER
15+41.22, 59.58' LT (W)
INSTALL 1 - 8"x4" TEE(MJ)
23 LF 4" D.I.
FIRELINE TO BLDG D
BLOCKING
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
19 LF 8" PVC
WATER MAIN
65 LF 4" DI FDC LINE FROM
BLDG C RISER ROOM TO
FDC
15+29.23, 109.00' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY
LABEL "BLDG C")
15+53.22, 109.00' LT INSTALL
1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO
CLEARLY LABEL "BLDG D)
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
15+41.22, 42.00' LT (W)
NSTALL 1 - 8"x4" TEE (MJ)
27 LF 4" D.I. FIRELINE TO
BLDG C BLOCKING
117 LF 8" PVC
WATER
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
24 LF 4" DI FIRELINE FROM BLDG K
RISER ROOM TO FDC
18+47.90, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG K")
18+64.93, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG L")
24 LF 4" DI FIRELINE FROM BLDG L
RISER ROOM TO FDC
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
34 LF 8" PVC
WATER
123 LF 8" PVC
WATER
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
68 LF 4" DI FIRELINE FROM
BLDG H RISER ROOM TO FDC
70 LF 4" DI FIRELINE FROM
BLDG J RISER ROOM TO FDC
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
17+39.33, 2.50' RT (W)
INSTALL
1-8" TEE (FL)
2- 8" GV (FLxMJ)
1 -8" ADAPTER
18+56.43, 36.00' RT (W) INSTALL
1 - 8"x4" CROSS (FLxMJ)
24LF 4" D.I. FIRELINE TO BLDG K
24LF 4" D.I. FIRELINE TO BLDG L
1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ)
1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY
(STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING
19+79.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
15+41.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
19+79.22, 82.00' LT (W) INSTALL
1 - 8"x4" CROSS (MJ)
25LF 4" D.I. FIRELINE TO BLDG H
25LF 4" D.I. FIRELINE TO BLDG J
BLOCKING
15+00.52, 2.50' RT (W)
INSTALL 1 - 8"x6" TEE (FL)
1 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
1 - 6" GV (FLxRMJ)
41LF 6" D.I. PIPE
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(15+00.52, 43.97'RT)
BLOCKING
18+56.43, 2.50' RT (W)
INSTALL 1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
BLDG 'C'BLDG 'D'
BLDG 'H'BLDG 'J'
BLDG 'K'BLDG 'L'
EX
I
T
2'
1.
4
8
'
1.5'
8.17'
16
.
7
9
'
10
'
EX
I
T
2'
1.
5
'
1.5'
8.17'
34
.
3
1
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
48 LF 4" DI FIRELINE FROM
BLDG D RISER ROOM TO
FDC
41 LF 8" PVC
WATER
19+72.22, 141.48' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG H")
19+86.22, 143.82' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG J")
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'F'BLDG 'G'
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
D
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
BLDG 'D'EX
I
T
1.
4
8
'
1.5'
8.17'
16
.
7
9
'
10
'
EX
I
T
2'
1.
5
'
1.5'
8.17'
34
.
3
1
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
D
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "D"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "D" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "D" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
VICINITY MAP
N.T.S.
04/30/2024
11+
0
0
12
+
0
0
PI 10+42.00
P
I
1
1
+
1
4
.
6
7
PI 12+42.53
PI 12+65
.
5
4
16+00 17+00 18+00 19+00 20+00 21+00 22+00 22+92
C/L INT
12+00.00 (N) =
22+18.48 (W)
D
E
K
H
G
J M
L
VERTICAL DATUM MERIDIAN HORIZONTAL DATUM
NGVD 29 PER T.C.H.P.N. #1252BM
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
YELM HIGHWAY AND KILLION ROAD
ELEVATION = 246.39 (NGVD)
DATUM DATUM
PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER
AUDITOR'S FILE NO. 4620459
0
SCALE: 1" = 30'
30 15 30 60
SEE SHEET 29
SEE SHEET 29
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
198 LF 8" PVC
WATER
239 LF 8" PVC
WATER 22+18.48, 2.50' RT (W) =
12+02.17, 0.00' RT (N)
INSTALL
1 - 8" TEE (FL)
1 - 8" ADAPTER (FLxMJ)
2 - 8" GV (FLxMJ)
BLOCKING
TA
H
O
M
A
B
L
V
D
.
EA
S
T
WE
S
T
NORTH
NE
KEY MAP
N.T.S.
LO
N
G
M
I
R
E
HA
T
T
O
N
GO
D
A
T
PA
N
T
I
E
R
84 LF 8" PVC
WATER
61 LF 8" PVC WATER
19+79.22, 132.65' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(19+79.22, 142.65' LT)
BLOCKING
17+39.24, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(17+39.24, 109.00' LT)
BLOCKING
15+41.22, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(15+41.22, 109.00' LT)
BLOCKING
50 LF 8" PVC WATER
15+41.22, 59.58' LT (W)
INSTALL 1 - 8"x4" TEE(MJ)
23 LF 4" D.I.
FIRELINE TO BLDG D
BLOCKING
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
19 LF 8" PVC
WATER MAIN
15+53.22, 109.00' LT INSTALL
1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO
CLEARLY LABEL "BLDG D)
117 LF 8" PVC
WATER
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
24 LF 4" DI FIRELINE FROM BLDG K
RISER ROOM TO FDC
18+47.90, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG K")
18+64.93, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG L")
24 LF 4" DI FIRELINE FROM BLDG L
RISER ROOM TO FDC
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
34 LF 8" PVC
WATER
123 LF 8" PVC
WATER
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
68 LF 4" DI FIRELINE FROM
BLDG H RISER ROOM TO FDC
70 LF 4" DI FIRELINE FROM
BLDG J RISER ROOM TO FDC
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
17+39.33, 2.50' RT (W)
INSTALL
1-8" TEE (FL)
2- 8" GV (FLxMJ)
1 -8" ADAPTER
18+56.43, 36.00' RT (W) INSTALL
1 - 8"x4" CROSS (FLxMJ)
24LF 4" D.I. FIRELINE TO BLDG K
24LF 4" D.I. FIRELINE TO BLDG L
1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ)
1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY
(STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING
19+79.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
15+41.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
19+79.22, 82.00' LT (W) INSTALL
1 - 8"x4" CROSS (MJ)
25LF 4" D.I. FIRELINE TO BLDG H
25LF 4" D.I. FIRELINE TO BLDG J
BLOCKING
18+56.43, 2.50' RT (W)
INSTALL 1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
BLDG 'D'
BLDG 'H'BLDG 'J'
BLDG 'K'BLDG 'L'
EX
I
T
2'
1.
5
'
1.5'
8.17'
34
.
3
1
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
48 LF 4" DI FIRELINE FROM
BLDG D RISER ROOM TO
FDC
19+72.22, 141.48' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG H")
19+86.22, 143.82' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG J")
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'F'BLDG 'G'
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
BLDG 'H'BLDG 'J'
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'F'BLDG 'G'
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
H
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "H
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "H" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "H" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
VICINITY MAP
N.T.S.
04/30/2024
11+
0
0
12
+
0
0
PI 10+42.00
P
I
1
1
+
1
4
.
6
7
PI 12+42.53
PI 12+65
.
5
4
16+00 17+00 18+00 19+00 20+00 21+00 22+00 22+92
C/L INT
12+00.00 (N) =
22+18.48 (W)
D
E
K
H
G
J M
L
VERTICAL DATUM MERIDIAN HORIZONTAL DATUM
NGVD 29 PER T.C.H.P.N. #1252BM
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
YELM HIGHWAY AND KILLION ROAD
ELEVATION = 246.39 (NGVD)
DATUM DATUM
PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER
AUDITOR'S FILE NO. 4620459
0
SCALE: 1" = 30'
30 15 30 60
SEE SHEET 29
SEE SHEET 29
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
198 LF 8" PVC
WATER
239 LF 8" PVC
WATER 22+18.48, 2.50' RT (W) =
12+02.17, 0.00' RT (N)
INSTALL
1 - 8" TEE (FL)
1 - 8" ADAPTER (FLxMJ)
2 - 8" GV (FLxMJ)
BLOCKING
TA
H
O
M
A
B
L
V
D
.
EA
S
T
WE
S
T
NORTH
NE
KEY MAP
N.T.S.
LO
N
G
M
I
R
E
HA
T
T
O
N
GO
D
A
T
PA
N
T
I
E
R
84 LF 8" PVC
WATER
61 LF 8" PVC WATER
19+79.22, 132.65' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(19+79.22, 142.65' LT)
BLOCKING
17+39.24, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(17+39.24, 109.00' LT)
BLOCKING
15+41.22, 99.00' LT
INSTALL
1 - 8"x6" REDUCER (MJxFL)
1 - 6" GV (FLxRMJ)
1 - HYDT ASSEMBLY
(STD DWG 4-7)
(15+41.22, 109.00' LT)
BLOCKING
50 LF 8" PVC WATER
15+41.22, 59.58' LT (W)
INSTALL 1 - 8"x4" TEE(MJ)
23 LF 4" D.I.
FIRELINE TO BLDG D
BLOCKING
DCDA LOCATED INSIDE
BUILDING SEE FIRE
PROTECTION PLANS
19 LF 8" PVC
WATER MAIN
15+53.22, 109.00' LT INSTALL
1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO
CLEARLY LABEL "BLDG D)
117 LF 8" PVC
WATER
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
24 LF 4" DI FIRELINE FROM BLDG K
RISER ROOM TO FDC
18+47.90, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG K")
18+64.93, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG L")
24 LF 4" DI FIRELINE FROM BLDG L
RISER ROOM TO FDC
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
34 LF 8" PVC
WATER
123 LF 8" PVC
WATER
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
68 LF 4" DI FIRELINE FROM
BLDG H RISER ROOM TO FDC
70 LF 4" DI FIRELINE FROM
BLDG J RISER ROOM TO FDC
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
17+39.33, 2.50' RT (W)
INSTALL
1-8" TEE (FL)
2- 8" GV (FLxMJ)
1 -8" ADAPTER
18+56.43, 36.00' RT (W) INSTALL
1 - 8"x4" CROSS (FLxMJ)
24LF 4" D.I. FIRELINE TO BLDG K
24LF 4" D.I. FIRELINE TO BLDG L
1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ)
1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY
(STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING
19+79.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
15+41.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
19+79.22, 82.00' LT (W) INSTALL
1 - 8"x4" CROSS (MJ)
25LF 4" D.I. FIRELINE TO BLDG H
25LF 4" D.I. FIRELINE TO BLDG J
BLOCKING
18+56.43, 2.50' RT (W)
INSTALL 1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
BLDG 'D'
BLDG 'H'BLDG 'J'
BLDG 'K'BLDG 'L'
EX
I
T
2'
1.
5
'
1.5'
8.17'
34
.
3
1
'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
48 LF 4" DI FIRELINE FROM
BLDG D RISER ROOM TO
FDC
19+72.22, 141.48' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG H")
19+86.22, 143.82' LT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG J")
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'F'BLDG 'G'
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
J
DCDA LOCATED INSIDE
BUILDING SEE
MECHANICAL PLANS
BLDG 'H'BLDG 'J'
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
5
'
1.5'
8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
BLDG 'F'BLDG 'G'
4" FLANGE TO 1'-0" AFF
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
J
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "J"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "J" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "J" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
VICINITY MAP
N.T.S.
04/30/2024
16+00 17+00 18+00 19+00 20+00
D
K
H
L
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
10' UTILITY EASEMENT
10' UTILITY EASEMENT
10' UTILITY EASEMENT
198 LF 8" PVC
WATER
84 LF 8" PVC
WATER
19 LF 8" PVC
WATER MAIN
117 LF 8" PVC
WATER
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
24 LF 4" DI FIRELINE FROM BLDG K
RISER ROOM TO FDC
18+47.90, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG K")
18+64.93, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG L")
24 LF 4" DI FIRELINE FROM BLDG L
RISER ROOM TO FDC
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
34 LF 8" PVC
WATER
123 LF 8" PVC
WATER17+39.33, 2.50' RT (W)
INSTALL
1-8" TEE (FL)
2- 8" GV (FLxMJ)
1 -8" ADAPTER
18+56.43, 36.00' RT (W) INSTALL
1 - 8"x4" CROSS (FLxMJ)
24LF 4" D.I. FIRELINE TO BLDG K
24LF 4" D.I. FIRELINE TO BLDG L
1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ)
1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY
(STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING
19+79.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
15+41.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
18+56.43, 2.50' RT (W)
INSTALL 1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
BLDG 'D'
BLDG 'K'BLDG 'L'
16
.
7
9
'
10
'
EX
I
T
1.
5
'
34
.
3
1
'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
WET SYSTEM
4" FLANGE TO 1'-0" AFF
WET SYSTEM
4" FLANGE TO 1'-0" AFF
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
8" WATER MAIN 8" WATER MAIN 8" WATER MAIN
8"
W
A
T
E
R
M
A
I
N
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
BLDG 'K'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
8.17'
8.
0
9
'
8" WATER MAIN
FIRE SPRINKLER
RISER ROOM
8"
W
A
T
E
R
M
A
I
N
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
K
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "K"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "K" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "K" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
F.D.C. BUILDING 'K'FIRE HYDRANT
VICINITY MAP
N.T.S.
04/30/2024
18+00 19+00 20+00 21+00 22+00
C/L INT
12+00.00 (N) =
22+18.48 (W)
H J
L
SEE SHEET 29
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
10' UTILITY EASEMENT
10' UTILITY EASEMENT
239 LF 8" PVC
WATER 22+18.48, 2.50' RT (W) =
12+02.17, 0.00' RT (N)
INSTALL
1 - 8" TEE (FL)
1 - 8" ADAPTER (FLxMJ)
2 - 8" GV (FLxMJ)
BLOCKING
84 LF 8" PVC
WATER
117 LF 8" PVC
WATER
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
24 LF 4" DI FIRELINE FROM BLDG K
RISER ROOM TO FDC
18+47.90, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG K")
18+64.93, 47.50' RT
INSTALL 1 - 4"x 2½"x2½" FDC
(CONTRACTOR TO CLEARLY LABEL "BLDG L")
24 LF 4" DI FIRELINE FROM BLDG L
RISER ROOM TO FDC
DCDA LOCATED INSIDE BUILDING
SEE MECHANICAL PLANS
34 LF 8" PVC
WATER
123 LF 8" PVC
WATER
18+56.43, 36.00' RT (W) INSTALL
1 - 8"x4" CROSS (FLxMJ)
24LF 4" D.I. FIRELINE TO BLDG K
24LF 4" D.I. FIRELINE TO BLDG L
1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ)
1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY
(STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING
19+79.22, 2.50' RT (W)
INSTALL
1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
18+56.43, 2.50' RT (W)
INSTALL 1 - 8" TEE (FL)
2 - 8" GV (FLxMJ)
1 - 8" ADAPTER (FLxMJ)
BLOCKING
BLDG 'K'BLDG 'L'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
RISER ROOM
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
8" WATER MAIN 8" WATER MAIN
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
8"
W
A
T
E
R
M
A
I
N
BLDG 'L'
8.17'
FIRE SPRINKLER
RISER ROOM
8.
1
9
'
2'
1.
1
9
'
1.5'8.17'
FIRE SPRINKLER
WET SYSTEM
4" FLANGE TO 1'-0" AFF
1.
4
8
'
8.
0
9
'
FIRE SPRINKLER
RISER ROOM
F.D.C. LINE
4" FLANGE TO 1'-0" AFF
8"
W
A
T
E
R
M
A
I
N
Da
t
e
:
Co
r
p
o
r
a
t
i
o
n
Sp
r
i
n
k
l
e
r
A
F
i
r
e
Dr
a
w
n
:
Fa
x
2
5
3
.
8
5
3
.
5
8
9
0
Ph
o
n
e
2
5
3
.
8
5
3
.
7
7
8
0
27
0
9
J
A
H
N
A
V
E
,
N
W
,
S
U
I
T
E
H
2
Gi
g
H
a
r
b
o
r
,
W
A
.
9
8
3
3
5
-
1
7
3
5
Co
n
t
.
L
i
c
.
#
S
P
R
I
N
F
P
0
1
1
L
S
FI
R
E
S
P
R
I
N
K
L
E
R
D
R
A
W
I
N
G
SCALE: 1" = 40'-0"
WA. STATE LEVEL 3 STAMP
F L
File:Tahoma Terra Storage Site FP.dwg
TA
H
O
M
A
T
E
R
R
A
S
T
O
R
A
G
E
B
U
I
L
D
I
N
G
"
L
"
TA
H
O
M
A
B
O
U
L
E
V
A
R
D
YE
L
M
,
W
A
9
8
5
9
7
04
/
3
0
/
2
0
2
4
PA
C
I
F
I
C
S
T
O
R
A
G
E
P
A
R
T
N
E
R
S
,
L
L
C
P.
O
.
B
O
X
7
3
7
9
0
PU
Y
A
L
L
U
P
,
W
A
9
8
3
7
3
PA
P
CI
T
Y
O
F
Y
E
L
M
B
L
D
G
/
F
I
R
E
O
F
F
I
C
I
A
L
(3
6
0
)
3
3
9
-
2
0
9
5
BLDG "L"
Sheet Number:
Sheet Title:
Project No.24-012CM
SCALE: 1" = 30'-0"
PROJECT
NORTH
BUILDING "L" FIRE PROTECTION SITE PLAN
0 60'30'15'
(2
5
3
)
2
2
3
-
7
4
3
2
CH
R
I
S
V
A
C
C
A
R
O
FP-1.1
BW
/
J
G
F
SCALE: 1" = 10'-0"
PROJECT
NORTH
BLDG "L" ENLARGED FIRE PROTECTION SITE PLAN
0 20'10'5'
13
C7
FIRE DEPARTMENT CONNECTION (FDC)
36"-42"
UNDERGROUND STUB UP W/ ROD
D.
I
.
P
.
R
I
S
E
R
L C
CONC. FOOTING
FOW
ATR & TIE BOLTS
OR- MEGA-LUG
RETAINERS TO RESTRAIN
VERTICAL PIPING
36
"
M
I
N
I
M
U
M
CORE OR SLEEVE
THRU FOOTING
IF REQUIRED
THRUST BLOCK (PER
NFPA 24)
PIPE SLEEVE THRU SLAB
MAINTAIN 2" GAP AROUND
FIRE LINE
FLANGE 1'-0" AFF
SLAB LEVEL EXT. WALL
1'-8"
MINIMUM
U.G. PIPING
UNDERGROUND NOTES:
1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install
Underground Piping Per WAC 212-80.
2) Pipe type and class to meet Local Jurisdiction Approval.
3) All underground piping shall have a Minimum 3'-0" Bury.
4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection.
5) All underground piping shall be rodded and/or blocked in accordance with the specifications and
NFPA 24.
6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in
accordance with NFPA 24.
7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until
water is clear as indicated by no collection of foreign material in burlap bags at outlets.
4" - 390 GPM 10" - 2,400 GPM
6" - 880 GPM 12" - 3,520 GPM
8" - 1,560 GPM
8) All underground installation and testing to be witnessed by the local authority having jurisdiction.
9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized
4 in. larger than the supply pipe size on pipes sized 4" or larger.
HEAD BOX
N.T.S.
RISER DETAIL
RISERD
UNDERGROUND STUB UP
2½" ANGLE HOSE
VALVE FOR
FORWARD FLOW
TESTING OF DCVA.
4" GROOVED
CHECK VALVE
DR
A
I
N
TO
4" FLANGE x
GROOVED
ADAPTER
4" DERINGER 30 DOUBLE CHECK
DETECTOR ASSEMBLY INDOOR
VERTICAL INSTALLATION w/(2)
BUTTERFLY TAMPER SWITCHES
4" RISER MANIFOLD W/:
(1)DRAIN AND TEST
(2)FLOW SWITCH
(3)WATER GAUGE
(4)SIGNS ON BODY
(5)PRV- KIT
4" GRVD
90º ELBOW
*Pressure Relief
Valve installed on
System Riser -or-
at Inspectors Test
Valve. See Detail
EXTERIOR 6" 24V
AC ALARM BELL
FIRE LINE BY OTHERS
MJ ELBOW
w/Restrained
Flange Adapters
MJ ELBOW
w/Restrained
Flange Adapters
Hoffman Construction, Inc.
159 16th Street East, Suite 101
Pacific, WA 98047-5005
PHONE: 360-825-9797
Randy Hoffman
Certification #3966-0899-D
Certification Level: U
Contractor # HOFFMCI931D9
WA STATE LEVEL U
INSTALLATION COMPANY INFO:
F.D.C. BUILDING 'L'FIRE HYDRANT
VICINITY MAP
N.T.S.
04/30/2024