Fire Underground Drawings-Tahoma Terra Storage ProjectFIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 6" FLANGE TO 1'-0" AFF F.D.C. LINE 6" FLANGE TO 1'-0" AFF BLDG 'B' BLDG 'A' BLDG 'C'BLDG 'D'BLDG 'H'BLDG 'J' BLDG 'L'BLDG 'K' BLDG 'G' BLDG 'F' BLDG 'E' BL D G ' M ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E F A C I L I T Y TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 OVERALL SITE PLAN Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 50'-0" PROJECT NORTH OVERALL SITE PLAN 0 100'50'25' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.0 BW / J G F PROJECT INFORMATION: COMMERCIAL SELF-STORAGE FACILITY WITH 12 BUILDINGS. BUILDINGS A, B, C, D, H, J, K, L ARE FULLY SPRINKLERED BUILDINGS E, F, G, M ARE NON-SPRINKLERED. Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: FLOW TEST INFORMATION 04/30/2024 1'-6" 2' 1' 1. 5 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGES TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 11 + 0 0 10+00 11+00 13+00 12+00 1 4 + 0 0 P I 1 0 + 4 5 . 0 1 P I 1 1 + 1 4 . 4 1 PI 1 3 + 2 9 . 5 7 C/L INT 10+00.00 (E) = 11+03.20 (W) C/L INT 10+00.00 (W)= TAHOMA BLVD = N 593867.32 E 1109087.59 BLDG 'A' A B C VERTICAL DATUM MERIDIAN HORIZONTAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 0 SCALE: 1" = 30' 30 15 30 60 HAT T O N GOD A T PAN T I E R MAT C H L I N E 14+ 0 0 . 0 0 COFFEE SHOP RETAIL STORAGE OFFICE MAINTAIN 42" MINIMUM COVER OVER WATERMAIN FROM FINISH GRADE T A H O M A B L V D S E LONG M I R E S T S E SEE S H E E T 2 6 30 ' I N G R E S S , E G R E S S A N D U T I L I T Y E A S E M E N T 1 0 ' M I N . 10' U T I L I T Y E A S E M E N T EXISTING FIRE HYDRANT (TYP) SE E S H E E T 2 7 36 LF 8" PVC WATER 11+74.72, 2.50' RT (W) INSTALL 1 - 8"x4" TEE (MJxFL) 1 - 4" GV (FLxMJ) 31 LF 4" D.I. PIPE BLOCKING 11+05.64, 6.22' RT (W)= 10+06.49, 1.59' RT (E) INSTALL 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) 1 - 8" GV (FLxMJ) 1 - 8" GV (FL) 1 - 8" 22-1/2° BEND (FL) 1 - 8" 11-1/4° BEND (FLxMJ) BLOCKING18 LF 8" PVC WATER 52 LF 8" PVC WATER TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E 7 LF 8" PVC WATER 11+74.72, 31.39' LT (W) INSTALL 1 - 4" GV w/ POST INDICATOR BLOCKING FIRE SPRINKLER LINE DCDA INSIDE BUILDING (SEE MECHANICAL PLANS, TYP) 11+92.97, 16.83' LT (W) INSTALL 1 - FDC (CONTRACTOR TO CLEARLY LABEL BLDG ADDRESS) 12+52.23, 18.00' LT (W) INSTALL 1 - 5/8" WATER METER (RETAIL BLDG) 1 - RPBA 12+27.55, 39.00' RT (W) INSTALL 1 - 1-1/2" WATER METER (COFFEE SHOP) 1 - RPBA 11+31.91, 41.46' LT (W) INSTALL 1 - 5/8" WATER METER (STORAGE OFFICE) 1 - RPBA 170 LF 8" PVC WATER APPROXIMATE LOCATION OF EXISTING 10" WATERMAIN EXISTING 10" WATER STUB 12+53.22, 26.00' LT (W) INSTALL 1 - 5/8" WATER IRRIGATION w/ DCVA/BACKFLOW PREVENTER TO BE INSTALLED BY LANDSCAPE CONTRACTOR (SEE LANDSCAPE PLAN) 10+73.97, 17.00' LT (W) INSTALL 1 - 5/8" WATER IRRIGATION w/ DCVA/BACKFLOW PREVENTER TO BE INSTALLED BY LANDSCAPE CONTRACTOR (SEE LANDSCAPE PLAN) 4" SCH 40 CONDUIT W/ TRACER WIRE FOR IRRIGATION CROSSING (TYP) 117 LF 8" PVC WATER 13+34.58, 79.00' LT (W) INSTALL 1 - HYDT ASSEMBLY (STD DRAWING 4-7) BLOCKING EX I T 1. 2 7 ' 2' 1.5' 8.17' 16 . 6 ' 104 LF 4" DI FDC LINE FROM BLDG A RISER ROOM TO FDC N 594055.33 E 1108785.12 INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG B") 13+09.33, 2.50' RT (W) INSTALL 1 - 8"x4" TEE (MJ) 17 LF 4" D.I. FIRELINE TO BLDG A BLOCKING N 594066.15 E 1108773.31 INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG A") BLDG 'B' DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 13+34.58, 51.81' LT (W) INSTALL 1 - 8"x4" TEE (MJ) 1- 4" 45 DEG ELL (MJ) 37 LF 4" D.I. FIRELINE TO BLDG B BLOCKING 8" WATER MAIN 8" WATER MAIN 8 " W A T E R M A I N 8" W A T E R M A I N 8" W A T E R M A I N 11+78.95, 2.50' RT (W) INSTALL 1- 8"x6" TEE (MJxFL) 1- 6" GV (FLxRMJ) (STD DWG 4-11) 1-HYDT ASSEMBLY (STD DWG 4-7) (11+78.95, 18.50'RT) BLOCKING 10+69.51, 5.50' RT (W) REMOVE EXISTING CAP & BLOWOFF INSTALL 1 - 10"x8" REDUCER CONTRACTOR TO FIELD VERIFY BLOCKING LOCATION, DEPTH, SIZE & FITTINGS REQUIRED PRIOR TO CONSTRUCTION. 11+24.96, 2.50' RT (W) INSTALL 1 - 8" 11-1/4° BEND (MJ) BLOCKING (STD DWG 4-13) 13+28.57, 2.50' RT (W) INSTALL 1 - 8" 45° BEND (MJxFL) 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) BLOCKING 55 LF 8" PVC WATER 26 LF 8" PVC WATER 1'-6" 2' 1 ' 1. 5 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGES TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'A' A COFFEE SHOP 8" WATER MAIN 8 " W A T E R M A I N 8" W A T E R M A I N Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " A " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "A" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "A" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "A" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: VICINITY MAP N.T.S. FLOW TEST INFORMATION 04/30/2024 1'-6" 2' 1' 1. 5 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGES TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 11 + 0 0 10+00 11+00 13+00 12+00 1 4 + 0 0 P I 1 0 + 4 5 . 0 1 P I 1 1 + 1 4 . 4 1 PI 1 3 + 2 9 . 5 7 C/L INT 10+00.00 (E) = 11+03.20 (W) C/L INT 10+00.00 (W)= TAHOMA BLVD = N 593867.32 E 1109087.59 BLDG 'A' A B C VERTICAL DATUM MERIDIAN HORIZONTAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 0 SCALE: 1" = 30' 30 15 30 60 HAT T O N GOD A T PAN T I E R MAT C H L I N E 14+ 0 0 . 0 0 COFFEE SHOP RETAIL STORAGE OFFICE MAINTAIN 42" MINIMUM COVER OVER WATERMAIN FROM FINISH GRADE T A H O M A B L V D S E LONG M I R E S T S E SEE S H E E T 2 6 30 ' I N G R E S S , E G R E S S A N D U T I L I T Y E A S E M E N T 1 0 ' M I N . 10' U T I L I T Y E A S E M E N T EXISTING FIRE HYDRANT (TYP) SE E S H E E T 2 7 36 LF 8" PVC WATER 11+74.72, 2.50' RT (W) INSTALL 1 - 8"x4" TEE (MJxFL) 1 - 4" GV (FLxMJ) 31 LF 4" D.I. PIPE BLOCKING 11+05.64, 6.22' RT (W)= 10+06.49, 1.59' RT (E) INSTALL 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) 1 - 8" GV (FLxMJ) 1 - 8" GV (FL) 1 - 8" 22-1/2° BEND (FL) 1 - 8" 11-1/4° BEND (FLxMJ) BLOCKING18 LF 8" PVC WATER 52 LF 8" PVC WATER TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E 7 LF 8" PVC WATER 11+74.72, 31.39' LT (W) INSTALL 1 - 4" GV w/ POST INDICATOR BLOCKING FIRE SPRINKLER LINE DCDA INSIDE BUILDING (SEE MECHANICAL PLANS, TYP) 11+92.97, 16.83' LT (W) INSTALL 1 - FDC (CONTRACTOR TO CLEARLY LABEL BLDG ADDRESS) 12+52.23, 18.00' LT (W) INSTALL 1 - 5/8" WATER METER (RETAIL BLDG) 1 - RPBA 12+27.55, 39.00' RT (W) INSTALL 1 - 1-1/2" WATER METER (COFFEE SHOP) 1 - RPBA 11+31.91, 41.46' LT (W) INSTALL 1 - 5/8" WATER METER (STORAGE OFFICE) 1 - RPBA 170 LF 8" PVC WATER APPROXIMATE LOCATION OF EXISTING 10" WATERMAIN EXISTING 10" WATER STUB 12+53.22, 26.00' LT (W) INSTALL 1 - 5/8" WATER IRRIGATION w/ DCVA/BACKFLOW PREVENTER TO BE INSTALLED BY LANDSCAPE CONTRACTOR (SEE LANDSCAPE PLAN) 10+73.97, 17.00' LT (W) INSTALL 1 - 5/8" WATER IRRIGATION w/ DCVA/BACKFLOW PREVENTER TO BE INSTALLED BY LANDSCAPE CONTRACTOR (SEE LANDSCAPE PLAN) 4" SCH 40 CONDUIT W/ TRACER WIRE FOR IRRIGATION CROSSING (TYP) 117 LF 8" PVC WATER 13+34.58, 79.00' LT (W) INSTALL 1 - HYDT ASSEMBLY (STD DRAWING 4-7) BLOCKING EX I T 1. 2 7 ' 2' 1.5' 8.17' 16 . 6 ' 104 LF 4" DI FDC LINE FROM BLDG A RISER ROOM TO FDC N 594055.33 E 1108785.12 INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG B") 13+09.33, 2.50' RT (W) INSTALL 1 - 8"x4" TEE (MJ) 17 LF 4" D.I. FIRELINE TO BLDG A BLOCKING N 594066.15 E 1108773.31 INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG A") BLDG 'B' DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 13+34.58, 51.81' LT (W) INSTALL 1 - 8"x4" TEE (MJ) 1- 4" 45 DEG ELL (MJ) 37 LF 4" D.I. FIRELINE TO BLDG B BLOCKING 8" WATER MAIN 8" WATER MAIN 8 " W A T E R M A I N 8" W A T E R M A I N 8" W A T E R M A I N 11+78.95, 2.50' RT (W) INSTALL 1- 8"x6" TEE (MJxFL) 1- 6" GV (FLxRMJ) (STD DWG 4-11) 1-HYDT ASSEMBLY (STD DWG 4-7) (11+78.95, 18.50'RT) BLOCKING 10+69.51, 5.50' RT (W) REMOVE EXISTING CAP & BLOWOFF INSTALL 1 - 10"x8" REDUCER CONTRACTOR TO FIELD VERIFY BLOCKING LOCATION, DEPTH, SIZE & FITTINGS REQUIRED PRIOR TO CONSTRUCTION. 11+24.96, 2.50' RT (W) INSTALL 1 - 8" 11-1/4° BEND (MJ) BLOCKING (STD DWG 4-13) 13+28.57, 2.50' RT (W) INSTALL 1 - 8" 45° BEND (MJxFL) 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) BLOCKING 55 LF 8" PVC WATER 26 LF 8" PVC WATER B EX I T 1. 2 7 ' 2' 1.5' 8.17' 16 . 6 ' BLDG 'B' DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" WATER MAIN 8" W A T E R M A I N Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " B " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "B" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "B" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "B" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: F.D.C. BUILDING 'B' F.D.C. BUILDING 'A' FIRE HYDRANT VICINITY MAP N.T.S. 04/30/2024 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 D E K H G J L C BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF TOPOGRAPHIC NOTE: THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. MA T C H L I N E 14 + 0 0 . 0 0 SE E S H E E T 2 5 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 170 LF 8" PVC WATER 198 LF 8" PVC WATER 239 LF 8" PVC WATER TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E 84 LF 8" PVC WATER 61 LF 8" PVC WATER 19+79.22, 132.65' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (19+79.22, 142.65' LT) BLOCKING 17+39.24, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (17+39.24, 109.00' LT) BLOCKING 15+41.22, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+41.22, 109.00' LT) BLOCKING 50 LF 8" PVC WATER 18 LF 8" PVC WATER 15+41.22, 59.58' LT (W) INSTALL 1 - 8"x4" TEE(MJ) 23 LF 4" D.I. FIRELINE TO BLDG D BLOCKING DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 19 LF 8" PVC WATER MAIN 65 LF 4" DI FDC LINE FROM BLDG C RISER ROOM TO FDC 15+29.23, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG C") 15+53.22, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG D) DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 15+41.22, 42.00' LT (W) NSTALL 1 - 8"x4" TEE (MJ) 27 LF 4" D.I. FIRELINE TO BLDG C BLOCKING 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 24 LF 4" DI FIRELINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 24 LF 4" DI FIRELINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 68 LF 4" DI FIRELINE FROM BLDG H RISER ROOM TO FDC 70 LF 4" DI FIRELINE FROM BLDG J RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 17+39.33, 2.50' RT (W) INSTALL 1-8" TEE (FL) 2- 8" GV (FLxMJ) 1 -8" ADAPTER 18+56.43, 36.00' RT (W) INSTALL 1 - 8"x4" CROSS (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 15+41.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 19+79.22, 82.00' LT (W) INSTALL 1 - 8"x4" CROSS (MJ) 25LF 4" D.I. FIRELINE TO BLDG H 25LF 4" D.I. FIRELINE TO BLDG J BLOCKING 15+00.52, 2.50' RT (W) INSTALL 1 - 8"x6" TEE (FL) 1 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 1 - 6" GV (FLxRMJ) 41LF 6" D.I. PIPE 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+00.52, 43.97'RT) BLOCKING 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'C'BLDG 'D' BLDG 'H'BLDG 'J' BLDG 'K'BLDG 'L' EX I T 2' 1. 4 8 ' 1.5' 8.17' 16 . 7 9 ' 10 ' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N 48 LF 4" DI FIRELINE FROM BLDG D RISER ROOM TO FDC 41 LF 8" PVC WATER 19+72.22, 141.48' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG H") 19+86.22, 143.82' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG J") FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N C DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS BLDG 'C' EX I T 2' 1. 4 8 ' 1.5' 8.17' 16 . 7 9 ' 10 ' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " C " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "C" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "C" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "C" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: VICINITY MAP N.T.S. 04/30/2024 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 D E K H G J L C BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF TOPOGRAPHIC NOTE: THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. MA T C H L I N E 14 + 0 0 . 0 0 SE E S H E E T 2 5 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 170 LF 8" PVC WATER 198 LF 8" PVC WATER 239 LF 8" PVC WATER TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E 84 LF 8" PVC WATER 61 LF 8" PVC WATER 19+79.22, 132.65' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (19+79.22, 142.65' LT) BLOCKING 17+39.24, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (17+39.24, 109.00' LT) BLOCKING 15+41.22, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+41.22, 109.00' LT) BLOCKING 50 LF 8" PVC WATER 18 LF 8" PVC WATER 15+41.22, 59.58' LT (W) INSTALL 1 - 8"x4" TEE(MJ) 23 LF 4" D.I. FIRELINE TO BLDG D BLOCKING DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 19 LF 8" PVC WATER MAIN 65 LF 4" DI FDC LINE FROM BLDG C RISER ROOM TO FDC 15+29.23, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG C") 15+53.22, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG D) DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 15+41.22, 42.00' LT (W) NSTALL 1 - 8"x4" TEE (MJ) 27 LF 4" D.I. FIRELINE TO BLDG C BLOCKING 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 24 LF 4" DI FIRELINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 24 LF 4" DI FIRELINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 68 LF 4" DI FIRELINE FROM BLDG H RISER ROOM TO FDC 70 LF 4" DI FIRELINE FROM BLDG J RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 17+39.33, 2.50' RT (W) INSTALL 1-8" TEE (FL) 2- 8" GV (FLxMJ) 1 -8" ADAPTER 18+56.43, 36.00' RT (W) INSTALL 1 - 8"x4" CROSS (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 15+41.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 19+79.22, 82.00' LT (W) INSTALL 1 - 8"x4" CROSS (MJ) 25LF 4" D.I. FIRELINE TO BLDG H 25LF 4" D.I. FIRELINE TO BLDG J BLOCKING 15+00.52, 2.50' RT (W) INSTALL 1 - 8"x6" TEE (FL) 1 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 1 - 6" GV (FLxRMJ) 41LF 6" D.I. PIPE 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+00.52, 43.97'RT) BLOCKING 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'C'BLDG 'D' BLDG 'H'BLDG 'J' BLDG 'K'BLDG 'L' EX I T 2' 1. 4 8 ' 1.5' 8.17' 16 . 7 9 ' 10 ' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N 48 LF 4" DI FIRELINE FROM BLDG D RISER ROOM TO FDC 41 LF 8" PVC WATER 19+72.22, 141.48' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG H") 19+86.22, 143.82' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG J") FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N D DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS BLDG 'D'EX I T 1. 4 8 ' 1.5' 8.17' 16 . 7 9 ' 10 ' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " D " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "D" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "D" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "D" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: VICINITY MAP N.T.S. 04/30/2024 11+ 0 0 12 + 0 0 PI 10+42.00 P I 1 1 + 1 4 . 6 7 PI 12+42.53 PI 12+65 . 5 4 16+00 17+00 18+00 19+00 20+00 21+00 22+00 22+92 C/L INT 12+00.00 (N) = 22+18.48 (W) D E K H G J M L VERTICAL DATUM MERIDIAN HORIZONTAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 0 SCALE: 1" = 30' 30 15 30 60 SEE SHEET 29 SEE SHEET 29 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 198 LF 8" PVC WATER 239 LF 8" PVC WATER 22+18.48, 2.50' RT (W) = 12+02.17, 0.00' RT (N) INSTALL 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) 2 - 8" GV (FLxMJ) BLOCKING TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E HA T T O N GO D A T PA N T I E R 84 LF 8" PVC WATER 61 LF 8" PVC WATER 19+79.22, 132.65' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (19+79.22, 142.65' LT) BLOCKING 17+39.24, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (17+39.24, 109.00' LT) BLOCKING 15+41.22, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+41.22, 109.00' LT) BLOCKING 50 LF 8" PVC WATER 15+41.22, 59.58' LT (W) INSTALL 1 - 8"x4" TEE(MJ) 23 LF 4" D.I. FIRELINE TO BLDG D BLOCKING DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 19 LF 8" PVC WATER MAIN 15+53.22, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG D) 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 24 LF 4" DI FIRELINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 24 LF 4" DI FIRELINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 68 LF 4" DI FIRELINE FROM BLDG H RISER ROOM TO FDC 70 LF 4" DI FIRELINE FROM BLDG J RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 17+39.33, 2.50' RT (W) INSTALL 1-8" TEE (FL) 2- 8" GV (FLxMJ) 1 -8" ADAPTER 18+56.43, 36.00' RT (W) INSTALL 1 - 8"x4" CROSS (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 15+41.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 19+79.22, 82.00' LT (W) INSTALL 1 - 8"x4" CROSS (MJ) 25LF 4" D.I. FIRELINE TO BLDG H 25LF 4" D.I. FIRELINE TO BLDG J BLOCKING 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'D' BLDG 'H'BLDG 'J' BLDG 'K'BLDG 'L' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N 48 LF 4" DI FIRELINE FROM BLDG D RISER ROOM TO FDC 19+72.22, 141.48' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG H") 19+86.22, 143.82' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG J") FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS BLDG 'H'BLDG 'J' 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' F.D.C. LINE 4" FLANGE TO 1'-0" AFF Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " H " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "H Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "H" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "H" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: VICINITY MAP N.T.S. 04/30/2024 11+ 0 0 12 + 0 0 PI 10+42.00 P I 1 1 + 1 4 . 6 7 PI 12+42.53 PI 12+65 . 5 4 16+00 17+00 18+00 19+00 20+00 21+00 22+00 22+92 C/L INT 12+00.00 (N) = 22+18.48 (W) D E K H G J M L VERTICAL DATUM MERIDIAN HORIZONTAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 0 SCALE: 1" = 30' 30 15 30 60 SEE SHEET 29 SEE SHEET 29 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 198 LF 8" PVC WATER 239 LF 8" PVC WATER 22+18.48, 2.50' RT (W) = 12+02.17, 0.00' RT (N) INSTALL 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) 2 - 8" GV (FLxMJ) BLOCKING TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E HA T T O N GO D A T PA N T I E R 84 LF 8" PVC WATER 61 LF 8" PVC WATER 19+79.22, 132.65' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (19+79.22, 142.65' LT) BLOCKING 17+39.24, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (17+39.24, 109.00' LT) BLOCKING 15+41.22, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+41.22, 109.00' LT) BLOCKING 50 LF 8" PVC WATER 15+41.22, 59.58' LT (W) INSTALL 1 - 8"x4" TEE(MJ) 23 LF 4" D.I. FIRELINE TO BLDG D BLOCKING DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 19 LF 8" PVC WATER MAIN 15+53.22, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG D) 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 24 LF 4" DI FIRELINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 24 LF 4" DI FIRELINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 68 LF 4" DI FIRELINE FROM BLDG H RISER ROOM TO FDC 70 LF 4" DI FIRELINE FROM BLDG J RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 17+39.33, 2.50' RT (W) INSTALL 1-8" TEE (FL) 2- 8" GV (FLxMJ) 1 -8" ADAPTER 18+56.43, 36.00' RT (W) INSTALL 1 - 8"x4" CROSS (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 15+41.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 19+79.22, 82.00' LT (W) INSTALL 1 - 8"x4" CROSS (MJ) 25LF 4" D.I. FIRELINE TO BLDG H 25LF 4" D.I. FIRELINE TO BLDG J BLOCKING 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'D' BLDG 'H'BLDG 'J' BLDG 'K'BLDG 'L' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N 48 LF 4" DI FIRELINE FROM BLDG D RISER ROOM TO FDC 19+72.22, 141.48' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG H") 19+86.22, 143.82' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG J") FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N J DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS BLDG 'H'BLDG 'J' 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' 4" FLANGE TO 1'-0" AFF Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " J " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "J" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "J" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "J" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: VICINITY MAP N.T.S. 04/30/2024 16+00 17+00 18+00 19+00 20+00 D K H L 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 198 LF 8" PVC WATER 84 LF 8" PVC WATER 19 LF 8" PVC WATER MAIN 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 24 LF 4" DI FIRELINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 24 LF 4" DI FIRELINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER17+39.33, 2.50' RT (W) INSTALL 1-8" TEE (FL) 2- 8" GV (FLxMJ) 1 -8" ADAPTER 18+56.43, 36.00' RT (W) INSTALL 1 - 8"x4" CROSS (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 15+41.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'D' BLDG 'K'BLDG 'L' 16 . 7 9 ' 10 ' EX I T 1. 5 ' 34 . 3 1 ' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF WET SYSTEM 4" FLANGE TO 1'-0" AFF WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N BLDG 'K' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 8.17' 8. 0 9 ' 8" WATER MAIN FIRE SPRINKLER RISER ROOM 8" W A T E R M A I N Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " K " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "K" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "K" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "K" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: F.D.C. BUILDING 'K'FIRE HYDRANT VICINITY MAP N.T.S. 04/30/2024 18+00 19+00 20+00 21+00 22+00 C/L INT 12+00.00 (N) = 22+18.48 (W) H J L SEE SHEET 29 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 239 LF 8" PVC WATER 22+18.48, 2.50' RT (W) = 12+02.17, 0.00' RT (N) INSTALL 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) 2 - 8" GV (FLxMJ) BLOCKING 84 LF 8" PVC WATER 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 24 LF 4" DI FIRELINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 24 LF 4" DI FIRELINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER 18+56.43, 36.00' RT (W) INSTALL 1 - 8"x4" CROSS (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'K'BLDG 'L' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N BLDG 'L' 8.17' FIRE SPRINKLER RISER ROOM 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " L " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 04 / 3 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "L" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "L" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "L" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: F.D.C. BUILDING 'L'FIRE HYDRANT VICINITY MAP N.T.S. 04/30/2024