SB 84311_Yelm & Killion_ COMCheck Report - SignedCOMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Construction Site:
1406 E. Yelm AVE.
Yelm, Washington 98597
Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Starbucks Yelm, WA (Yelm and Killion)
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
1-INTERIOR (Retail)2280 0.84 1915
1915Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
INTERIOR (Retail, 2280 sq.ft.)
LED: 19049: Exit/ EM. LIGHTING: Other:1 2 5 Exempt
Exemption:Exit signs
LED: 20831: PENDANT: Other:1 3 6 18
LED: 21772: CAN LIGHT: Other:1 76 12 912
LED: 20750: SCONCE: Other:2 2 16 33
LED: X2851: SCONCE: Other:2 2 20 40
LED: 22216: STRIP: Other:1 49 4 196
LED: 22440: STRIP: Other:1 7 9 62
LED: 15057: TROFFER: Other:1 9 36 324
1585Total Proposed Watts =
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
Starbucks Yelm, WA (Yelm and Killion)05/02/24Report date:
61 ofPage
5/01/24Greg Sutyak, VP
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project Title:
2021 IECC
Project Type:Alteration
Construction Site:
1406 E. Yelm AVE.
Yelm, Washington 98597
Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Starbucks Yelm, WA (Yelm and Killion)
2 (Neighborhood business district (LZ2))Exterior Lighting Zone
Allowed Exterior Lighting Power
A
Area/Surface Category
B
Quantity
C
Allowed
Watts /
D
Tradable
Wattage
E
Allowed Watts
(B X C)
Exterior Wall (Illuminated area of facade wall or surface)361 ft2 0.07 No 27
Total Tradable Watts (a) =
Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
0
27
400
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
Exterior Wall (Illuminated area of facade wall or surface, 361 ft2): Non-tradable Wattage
LED: A: Uplighting: Other:1 9 23 206
0Total Tradable Proposed Watts =
Exterior Lighting Compliance
Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting
systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Exterior Lighting PASSES
Project Title:
Data filename:
Starbucks Yelm, WA (Yelm and Killion)05/02/24Report date:
62 ofPage
5/01/24Greg Sutyak, VP
Inspection Checklist
Requirements: 100.0% were addressed directly in the COMcheck software
COMcheck Software Version COMcheckWeb
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2021 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C103.2
[PR8]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the exterior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: E-102 AND E-601
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Starbucks Yelm, WA (Yelm and Killion)05/02/24Report date:
63 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.3.
1
[EL22]1
Spaces required to have light-
reduction controls have a manual
control that allows the occupant to
reduce the connected lighting load in
a reasonably uniform illumination
pattern >= 50 percent.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-102
C405.2.1,
C405.2.1.
1
[EL18]1
Occupancy sensors installed in
classrooms/lecture/training rooms,
conference/meeting/multipurpose
rooms, copy/print rooms,
lounges/breakrooms, enclosed offices,
open plan office areas, restrooms,
storage rooms, locker rooms,
corridors, warehouse storage areas,
and other spaces <= 300 sqft that are
enclosed by floor-to-ceiling height
partitions. Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-102
C405.2.1.
2
[EL19]1
Occupancy sensors control function in
warehouses: In warehouses, the
lighting in aisleways and open areas is
controlled with occupant sensors that
automatically reduce lighting power
by 50% or more within 20 minutes of
when the areas are unoccupied. The
occupant sensors control lighting in
each aisleway independently and do
not control lighting beyond the
aisleway being controlled by the
sensor. Lights not turned off by
occupant sensors is done so by time-
switch.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.1.
3
[EL20]1
Occupant sensor control function in
open plan office areas: Occupant
sensor controls in open office spaces
>= 300 sq.ft. have controls 1)
configured so that general lighting can
be controlled separately in control
zones with floor areas <= 600 sq.ft.
within the space, 2) general lighting in
each zone permitted to turn on upon
occupancy in control zone, 3)
automatically turn off general lighting
in all control zones within 20 minutes
after all occupants have left the
space, 4) are configured so that
general lighting power in each control
zone is reduced by >= 80% of the full
zone general lighting power within 20
minutes of all occupants leaving that
control zone.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.2,
C405.2.2.
1
[EL21]2
Each area not served by occupancy
sensors (per C405.2.1.1) have time-
switch controls and functions detailed
in sections C405.2.2.1.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-102
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Starbucks Yelm, WA (Yelm and Killion)05/02/24Report date:
64 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.4,
C405.2.4.
1,
C405.2.4.
2
[EL23]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting. See code section C405.2.3
Daylight-responsive controls for
applicable spaces, C405.2.3.1 Daylight
responsive control function and
section C405.2.3.2 Sidelit zone.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-102
C405.2.5
[EL27]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-102
C405.2.7
[EL28]1
Automatic lighting controls for exterior
lighting installed. Controls will be
daylight controlled, set based on
business operation time-of-day, or
reduce connected lighting > 30%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: E-102 AND E-601
C405.7
[EL26]2
Low-voltage dry-type distribution
electric transformers meet the
minimum efficiency requirements of
Table C405.6.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.8
[EL27]2
Electric motors meet the minimum
efficiency requirements of Tables
C405.7(1) through C405.7(4).
Efficiency verified through certification
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist).
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.9.1,
C405.9.2
[EL28]2
Escalators and moving walks comply
with ASME A17.1/CSA B44 and have
automatic controls configured to
reduce speed to the minimum
permitted speed in accordance with
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.10
[EL29]2
Total voltage drop across the
combination of feeders and branch
circuits <= 5%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-601
C405.1.1
[EL30]2
At least 90% of dwelling unit
permanently installed lighting shall
have lamp efficacy >= 65 lm/W or
luminaires with efficacy >= 45 lm/W
or comply with C405.2.4 or C405.3.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.11,
C405.11.1
[EL31]2
50% of 15/20 amp receptacles
installed in enclosed offices,
conference rooms, copy rooms, break
rooms, classrooms and workstations
and > 25% of branch circuit feeders
for modular furniture will have
automatic receptacle control in
accordance with C405.11.1.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
Location on plans/spec: E-102
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Starbucks Yelm, WA (Yelm and Killion)05/02/24Report date:
65 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3,
C408.2.5.
2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.5.1
[FI19]1
Exterior lighting power is consistent
with what is shown on the approved
lighting plans, demonstrating
proposed watts are less than or equal
to allowed watts.
Complies
Does Not
Not Observable
Not Applicable
See the Exterior Lighting fixture schedule for values.
C408.1.1
[FI57]1
Building operations and maintenance
documents will be provided to the
owner. Documents will cover
manufacturers' information,
specifications, programming
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.5
[FI16]3
Furnished as-built drawings for
electric power systems within 90 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.3
[FI33]1
Lighting systems have been tested to
ensure proper calibration, adjustment,
programming, and operation.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: SHEET E-102
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Starbucks Yelm, WA (Yelm and Killion)05/02/24Report date:
66 ofPage