SB84311_Yelm & Killion_Permit Set_Building1.THE DRAWINGS AND PROJECT MANUAL TOGETHER CONSTITUTE THE CONTRACT DOCUMENTS FOR CONSTRUCTION. ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS UNLESS OTHERWISE NOTED. 2.GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO CONSTRUCTION. 3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION. 4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. 5.GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES. 6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. 7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS. 9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON-SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AT PROJECT CLOSE-OUT AS DESCRIBED IN THE GENERAL REQUIREMENTS OF THE PROJECT MANUAL. 10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. SEE THE PROJECT MANUAL FOR ADDITIONAL INFORMATION. 11.RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "RESPONSIBILITY". 12. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED. 13.ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS CONSTRUCTION MANAGER. GENERAL NOTESPROJECT CONTACTS MAILING ADDRESS: DESIGN MANAGER: ALINA PINCHUK GRAPHITE DESIGN GROUP 1809 7TH AVE STE 700 SEATTLE, WA 98101 (206) 519-5138 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH MS STOP: S-SD10 SEATTLE, WASHINGTON 98134 (206) 318-1575 CONSTRUCTION MANAGER: CHERYL PARROTT 2401 UTAH AVE S MS STOP: S-SD10 SEATTLE, WA 98124 (206) 618-8361 LANDLORD:JOHN WALKER URBAN OLYMPIC PO BOX 7534 OLYMPIA, WA 98507 ARCHITECT OF RECORD: GRAPHITE DESIGN GROUP 1809 7TH AVE STE 700 SEATTLE, WA 98101 (206) 224-3335 MEP CONSULTANT OF RECORD: WHS ENGINEERING, INC 2012 WEST 25TH ST, #200 CLEVELAND, OH 44113 INDEX OF SHEETS LEGEND:X - SHEET ISSUED R - SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY SEE TITLEBLOCK FOR REVISION ISSUE DATE(S) SCOPE OF WORK TENANT IMPROVEMENT OF A FIRST-TIME BUILD-OUT OF AN INTERIOR SPACE IN A NEW MULTI-TENANT SINGLE-LEVEL BUILDING WITH DRIVE- THRU FOR A COFFEE SHOP. WORK INCLUDES: NON-STRUCTURAL PARTITIONS, INTERIOR DOORS, SUSPENDED CEILINGS, LIGHTING, FINISHES, FURNIUTURE/CASEWORK/FOOD SERVICE EQUIPMENT INSTALLATION, ASSOCIATED MECHANICAL/PLUMBING/ELECTRICAL/GAS/TELECOMMUNICATION SYSTEMS. ALL EXTERIOR SIGNAGE TO BE UNDER SEPERATE PERMIT. CODE AUTHORITIES: BUILDING CODE:2021 INTERNATIONAL BUILDING CODE W/ WAC AMENDMENTS PLUMBING CODE:2021 UNIFORM PLUMBING CODE W/ WAC AMENDMENTS MECHANICAL CODE:2021 INTERNATIONAL MECHANICAL CODE W/ WAC AMENDMENTS ELECTRICAL CODE:2023 NATIONAL ELECTRICAL CODE (NEC) ENERGY CODE:2021 WASHINGTON STATE ENERGY CODE FIRE CODE:2021 INTERNATIONAL FIRE CODE W/ WAC AMENDMENTS HEALTH CODE:WASHINGTON STATE RETAIL FOOD CODE CHAPTER 246-215 (WAC) ACCESSIBILITY CODE:2017 ICC/ANSI A117.1 W/ WAC AMENDMENTS ZONING: PARCEL NUMBER:45170000400, 451700000010 LEASABLE AREA:2,300 SQ FT ZONING TYPE:C-1 PROPOSED USE:RETAIL ESTABLISHMENTS DEFERRED SUBMITTALS:SIGNAGE SITE INFORMATION VICINITY PLAN AERIAL MAP A/C AIR CONDITIONING ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AMP AMPERE ARCH ARCHITECT BOH BACK OF HOUSE CAB CABINET CL CENTER LINE CLG CEILING CM STARBUCKS CONSTRUCTION MANAGER CTR CENTER CX COMMISSIONING CXA COMMISSIONING AGENT DEG DEGREE DET DETAIL DIA DIAMETER DIM DIMENSION DM STARBUCKS DESIGN MANAGER DN DOWN EA EACH EL ELEVATION EQ EQUAL EXIST EXISTING EXT EXTERIOR FF&E FURNITURE, FIXTURE, AND EQUIPMENT FLR FLOOR FOH FRONT OF HOUSE FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER INSTALLED BY OWNER FT FOOT/FEET G GROUND GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD HC HOLLOW CORE HDW HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING I.D.INSIDE DIAMETER LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MEP "MECHANICAL, ELECTRICAL AND PLUMBING" MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT NL NIGHT LIGHT NTS NOT TO SCALE OC ON CENTER O.D.OUTSIDE DIAMETER PIR PASSIVE INFRARED SENSOR PLC PLACE R RADIUS REF REFERENCE REQ‘D REQUIRED REV REVISION RND ROUND SB STARBUCKS SC SOLID CORE SF SQUARE FEET SHT SHEET SIM SIMILAR SPEC SPECIFICATION SQ SQUARE TEMP TEMPORARY TYP TYPICAL UC UNDER COUNTER UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD ABBREVIATIONS X' XX" X N NORTH ARROW XXXX AFF ARCHITECTURAL SYMBOL LEGEND XXXXXW XX Scale: X =X 0 2 4 8 GRAPHIC SCALE DATUM POINT EXTERIOR ELEVATION CALL-OUT INTERIOR ELEVATION CALL-OUT SECTION CALL-OUT DETAIL CALL-OUT REVISION TAG PAINT TAG DESIGN ID TAG DOOR TAG WINDOW TAG SHEET NOTE CALLOUT ABOVE FINISH FLOOR HEIGHT TAG FINISH FACE TO FINISH FACE DIMENSION REVISION CLOUD PT XXXXX XXXXXX XXXXXD XX INTERIOR WALL TAG GC LL SB SV RESPONSIBILITY LEGEND GENERAL CONTRACTOR LANDLORD STARBUCKS SIGNAGE VENDOR OCCUPANCY TYPE:B (BUSINESS) BUILDING AREA:6,300 SQ FT. TENANT AREA:2,300 SQ FT. CONSTRUCTION TYPE:V-B FIRE SPRINKLER:YES BUILDING INFORMATION SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 G001 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE GENERAL INFORMATION SHEET SHEET TITLE P E R M I T S E T R E V I S I O N 1 R E V I S I O N 2 R E V I S I O N 3 R E V I S I O N 4 GENERAL G001 GENERAL INFORMATION X G002 LIFE SAFETY AND ACCESSIBILITY PLAN X G003 RENDERINGS - EXTERIOR R G004 RENDERINGS - INTERIOR R ARCHITECTURAL A001 ARCHITECTURAL SITE PLAN X A002 ENLARGED SITE PLANS X A003 SITE DETAILS X A004 SITE DETAILS X A005 SITE DETAILS X A101 BUILDING FLOOR PLAN X A102 BUILDING FLOOR PENETRATION PLAN X A201 BUILDING EXTERIOR ELEVATIONS X A501 BUILDING DETAILS X A601 WINDOW AND DOOR SCHEDULES & DETAILS X INTERIORS I101 FF & E PLAN X I102 ENLARGED FF & E PLAN X I103 CASEWORK PLAN X I104 REFLECTED CEILING PLAN X I105 FLOOR FINISH PLAN X I106 WALL FINISH PLAN X I201 INTERIOR FINISH ELEVATIONS X I202 INTERIOR FINISH ELEVATIONS X I203 INTERIOR FINISH ELEVATIONS X I401 RESTROOM PLAN & ELEVATIONS X I501 INTERIOR DETAILS - FLOOR X I502 INTERIOR DETAILS - WALL X I503 INTERIOR DETAILS - WALL/CEILING X I504 INTERIOR DETAILS - WALL/CEILING X I505 INTERIOR DETAILS - SUSPENDED CEILING X I506 INTERIOR DETAILS - MENU BOARDS X I601 INTERIOR FINISHES & CASEWORK SCHEDULES X I602 FF&E SCHEDULES X I603 PLUMBING & LIGHTING SCHEDULES X ELECTRICAL E001 ELECTRICAL NOTES X E002 ELECTRICAL NOTES X E003 ELECTRICAL ENERGY COMPLIANCE X E006 SITE ELECTRICAL PLAN X E101 POWER PLAN X E102 LIGHTING PLAN X E103 LOW VOLTAGE DESIGN PLAN X E501 ELECTRICAL DETAILS X E502 ELECTRICAL DETAILS X E503 ELECTRICAL EMS DETAILS X E601 PANELBOARD SCHEDULES X MECHANICAL M001 MECHANICAL NOTES X M101 MECHANICAL PLAN X M102 MECHANICAL ROOFTOP PLAN X M601 MECHANICAL SCHEDULES X PLUMBING P001 PLUMBING NOTES X P101 PLUMBING WASTE PLAN X P102 PLUMBING SUPPLY PLAN X P401 PLUMBING ISOMETRICS X P402 PLUMBING ISOMETRICS X P501 PLUMBING DETAILS X P601 PLUMBING SCHEDULES X Revision Schedule Rev Date By Description N N A. B. C. D. E. F. G. H. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER AUTHORIZED AGENT. (1004.9 IBC) EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SIMILAR SPACES. (1016.2 IBC) PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS BUILDING SHALL SATISFY THE FOLLOWING (1010.2.9 IBC): 1)THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. 2)THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG). 3)PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE LATCH SIDE. 4)PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305. 5)FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305. STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER ANY WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 MM) ABOVE THE WALKING SURFACE. EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. (1003.3.3) THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF SECTION 1011 AND AS NOTED BELOW: 1)EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. 2)EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL. 3)NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) LETTERING STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". (1010.2.4.3.2 IBC) EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 INCHES (860 MM) TO 48 INCHES (1220 MM) ABOVE FINISHED FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. (1010.2, 1010.2.3, 1010.2.5 IBC) LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND SUCH LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (11120 MM). (1010.1.4, 1010.1.5 IBC) MEANS OF EGRESS NOTES 1.THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL APPLICABLE CODES. 2.BARRIER-FREE PATH OF TRAVEL. 3.30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS. 4.67" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR ACCESS. 5.32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR. 6.POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR WHEELCHAIR ACCESSIBILITY. 7.PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS PER ALL APPLICABLE CODES. 8.PROVIDE TACTILE "EXIT" SIGNAGE. 9.PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE REQUIRED BY APPLICABLE LAWS OR CODES 10.PREP SINK. 11.WORK SINK. 12.HAND SINK. 13.3-COMP SINK. 14.MOP SINK. 15.RINSE SINK. 16.DISHWASHER. 17.HOT WATER HEATER. 18.WATER FILTRATION. KEYED NOTES LEGEND PATH OF TRAVEL EMERGENCY LIGHT BARRIER FREE PATH OF TRAVEL (MIN 3'-0" - NO PINCH POINT) EXIT SIGN FIRE EXTINGUISHER ADA ACCESSIBLE SEATING 30" (915MM) X 48" (1220MM) CLEAR AREA COMMON PATH OF TRAVEL FE BAR FLOOR:POLYVINYL FLOORING WALL:WALL TILE, BACKSPLASH, WITH POLYVINYL BASE CEILING:GYPSUM CEILING CAFE FLOOR:POLISHED CONCRETE WALL:WOOD PANELS, GYPSUM, WITH TILE BASE CEILING:GYPSUM, WOOD GRILLE SYSTEM WORKROOM FLOOR:POLYVINYL FLOORING WALL:FRP WITH POLYVINYL BASE CEILING:ACOUSTICAL CEILING TILE RESTROOM FLOOR:POLISHED CONCRETE WALL:PARTIAL HEIGHT TILE, GYPSUM, WITH TILE BASE CEILING:GYPSUM CEILING HEALTH DEPT. FINISH SCHEDULE A.GENERAL CONTRACTOR TO SCHEDULE WITH REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR APPROVED CONTRACTOR, CONTACT THE VENDOR. B.THE SPACE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C.ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. D.EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS E.WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. F.EACH HAND WASHING WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. G.REFERENCE INTERIOR SCHEDULE SHEETS (I600 SERIES) FOR ADDITIONAL INFORMATION. H.PROVIDE SNEEZE GUARDS WHERE REQUIRED BY JURISDICTION. I.ALL FOOD STORAGE AND DISPLAY SHELVING SHALL BE A MINIMUM 6" (150MM) ABOVE FINISH FLOOR. HEALTH DEPT. PLAN NOTES 71' - 1 0 3 / 4 " 35' - 7 1/4" 2" PATH OF TRAVEL 2 15'-6" 859 SF CAFE 540 SF ENGINE 463 SF WORKROOM 548 SF PATIO 52 SF RESTROOM VEST.48 SF RESTROOM 1 57 SF RESTROOM 2 GREATEST PATH OF TRAVEL 104'-8" PATH OF TRAVEL 1 33'-5" COMMON PATH OF TRAVEL 45'-8" POINT OF GREATEST REMOTENESSCOMMON PATH OF TRAVEL 11'-11" 1 1 2 4 3 4 4 5 5 6 7 79 9 10 11 13 12 141817 16 15 4 4 REQD PROV 15" 74 OCC 69" EXIT TO GRADE REQD PROV 15" 74 OCC 33" EXIT TO GRADE COMMON PATH OF TRAVEL 71'-3" 8 8 6 16 3 81 SF DRIVE-THRU SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 G002 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE LIFE SAFETY AND ACCESSIBILITY PLAN **RETAIL ESTABLISHMENT SERVES WATER UPON REQUEST. *IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67% OF THE REQUIRED WATER CLOSETS IN ASSEMBLY OCCUPANCIES. PROVIDED 2 UNISEX 0 M 2 UNISEX 0 REQUIRED 1 M 1 F 0 M 1 M 1 F 0 1 PER 25 FOR FIRST 50 AND 1 PER 50 FOR REMAINDER EXCEEDING 50 1 PER 40 FOR FIRST 80 AND 1 PER 80 FOR REMAINDER EXCEEDING 80 1 PER 100 OR STATIONFIXTURES WATER CLOSETS URINALS*LAVATORY WATER FOUNTAIN** 32 OCC.33 OCC.65 OCC.OCCUPANCY MALE FEMALE TOTAL CHAPTER29-2021 IBC TABLE 2902.1 PLUMBING FIXTURE CALCULATIONS EXIT SEPARATION PROVIDED = 35' - 7 1/4" MINIMUM. EXIT SEPARATION = 71' - 11 3/4" (MAXIMUM DIAGONAL) / 3 = 23' - 11 7/8" MAXIMUM. TRAVEL DISTANCE PROVIDED = 104' - 8" MAXIMUM. ALLOWABLE TRAVEL DISTANCE= 250' - 0" NUMBER OF EXITS PROVIDED = 2 NUMBER OF EXITS REQUIRED = 2 EXITS = 69 IN. PRIMARY ENTRY, 33 IN. SECONDARY ENTRY EXIT WIDTH PROVIDED = 102 IN. EXIT WIDTH REQUIRED - 74 OCC. x 0.2 = 15 IN. EGRESS CALCULATIONS Scale: 1/4" = 1'-0"1 LIFE SAFETY PLAN N Revision Schedule Rev Date By Description OCCUPANCY CALCULATIONS (EXTERIOR) NAME AREA CLASSIFICATION LOAD FACTOR (PER /SF)OCCUPANTS EXTERIOR PATIO 548 SF UNCOCENTRATED TABLES AND CHAIRS 15 37 EXTERIOR 548 SF 37 TOTAL OCCUPANTS COMBINED: 548 SF 37 OCCUPANCY CALCULATIONS (INTERIOR) NAME AREA CLASSIFICATION LOAD FACTOR (PER /SF)OCCUPANTS INTERIOR CAFE 859 SF UNCOCENTRATED TABLES AND CHAIRS 15 58 DRIVE-THRU 81 SF COMMERCIAL KITCHEN 200 1 ENGINE 540 SF COMMERCIAL KITCHEN 200 3 RESTROOM 1 48 SF ACCESSORY 0 0 RESTROOM 2 57 SF ACCESSORY 0 0 RESTROOM VEST. 52 SF ACCESSORY 0 0 WORKROOM 463 SF COMMERCIAL KITCHEN 200 3 INTERIOR 2100 SF 65 TOTAL OCCUPANTS COMBINED: 2100 SF 65 OCCUPANCY (FIXED SEATING) NAME LENGTH CLASSIFICATION LOAD FACTOR (OCC/LF)OCCUPANTS INTERIOR FIXED SEATING 16' - 6"ASSEMBLY CONCENTRATED 2' - 0"9 16' - 6"9 TOTAL OCCUPANTS (FIXED SEATING) 16' - 6"9 EXIT ACCESS DISTANCE 00 Common Path of Travel 4 71' - 3" 00 Common Path of Travel 5 45' - 8" 00 Common Path of Travel 6 11' - 11" 00 Common Path of Travel 128' - 11" 00 Exit Access Travel 1 33' - 5" 00 Exit Access Travel 2 15' - 6" 00 Exit Access Travel 49' - 0" TOTAL ACCESSIBLE SEAT (≥5%)2 TOTAL 27 SOFT SEATING 7 7 TABLE TOPS AT BANQUETTE 5 10 TABLE TOP, SQUARE 5 10 DESCRIPTION NUMBER OF ITEMS SEATS INDOOR SEATING CALCULATIONS TOTAL ACCESSIBLE SEATS ( ≥ 5% )1 TOTAL 16 TABLE TOP, ROUND 2 8 TABLE TOP, RECTANGLE 2 8 DESCRIPTION NUMBER OF ITEMS SEATS OUTDOOR SEATING CALCULATIONS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 G003 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE RENDERINGS - EXTERIOR Revision Schedule Rev Date By DescriptionNOTE: RENDERINGS ARE FOR ILLUSTRATION PURPOSES ONLY, FOR ANY DISCEPENCIES CD DRAWINGS SUPERSEDE VIEW OF DRIVE-THRU ORDER POINT VIEW OF EXTERIOR MURAL AND DRIVE-THRU VIEW OF BUILDING ENTRANCE AND PATIO VIEW OF DRIVE-THRU ENTRY VIEW OF DRIVE-THRU APPROACHVIEW OF BUILDING ENTRANCE, PARKING, AND DRIVE-THRU EXIT SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 G004 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE RENDERINGS - INTERIOR Revision Schedule Rev Date By Description NOTE: RENDERINGS ARE FOR ILLUSTRATION PURPOSES ONLY, FOR ANY DISCEPENCIES CD DRAWINGS SUPERSEDE VIEW OF CAFE ENTRY VIEW OF CAFE VIEW OF ENGINE VIEW OF RESTROOM VESTIBULE 1.LANDSCAPE AREA BY LL. 2.ACCESSIBLE PATH OF TRAVEL. 3. 6” CONCRETE CURB BY LL, TYPICAL. 4.CANOPY (ABOVE) BY LL. 5.MURAL UPLIGHTING PROVIDED BY LL. 6.PEDESTRIAN PATH BY LL TO TRASH ENCLOSURE. 7.COVERED TRASH ENCLOSURE CONCRETE APRON BY LL. 8.DT DIRECTIONAL ARROW SIGN, FOOTING BY LL. 9.WAYFINDING PAVEMENT GRAPHICS LL. 10.LOCATION OF MOP CUSTOMER PARKING SIGNAGE. 11. ADA PARKING SIGNAGE AND GROUND GRAPHICS BY LL. 12.APPROXIMATE LOCATION OF UNDERGROUND GREASE INTERCEPTOR BY LL. SEE LL PLUMBING PLANS. A.REFER TO EXTERIOR ELEVATIONS ON SHEET A201 FOR BUILDING SIGNAGE LOCATION AND DESIGN ID. REFER TO ELECTRICAL PLANS FOR ELECTRICAL REQUIREMENTS. B. LANDSCAPING BY LL TO BE PROVIDED PER ZONING CODE AND SUSTAINABILITY REQUIREMENTS. C. DRIVE-THRU EQUIPMENT INCLUDING VEHICLE DETECTION LOOP, WIRELESS COMMUNICATION AND MONITORS SHALL BE COORDINATED BY STARBUCKS CONSTRUCTION MANAGER AND INSTALLED BY LL. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. D. LL TO PROVIDE 6" (150MM) THICK CONCRETE PAVING THE LENGTH OF THE DRIVE-THRU LANE, EXTENT TO INCLUDE DRIVE-THRU ENTRY POINT THROUGH WINDOW STANDING PAD. E. LANDLORD TO APPLY CONCRETE SEALER TO ALL EXTERIOR CONCRETE PATIO AND WALKWAY SURFACES. F.GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION. G.LANDLORD TO PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT TRANSITION FROM SIDEWALK TO DRIVE AISLE. H.ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS. I.REFER TO LANDLORD ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK. J.SEE SHEET A003-5 FOR ARCHITECTURAL SITE DETAILS. KEYED NOTES GENERAL NOTES LANDSCAPE AREA BY LL LEGEND NEW 6" (150MM) CONCRETE CURB BY LL NEW CONCRETE WALKWAY BY LL CONCRETE DRIVE THRU LANE BY LL ACCESSIBLE PATH OF TRAVEL NEIGHBORING TENANTS 4,000 SF YE L M A V E N U E S E STARBUCKS 2,295 SF A002 1 A002 3 A002 2 Y 2311323113 9 Y 2311323113 9 9' - 2" 7' - 1 1 3 / 4 " 15' - 10 1/4" 25 ' - 1 1 " Y 2311923119 9 6' - 2 1/4" 1' - 4 1 / 4 " Y 2311923119 Y 2311723117 9 8' - 1 3 / 4 " 7' - 6 1 / 4 " 9 16' - 7 1 / 2 " Y 2311923119 Y 2311923119 9 9 7 S 212972129710 1 1 1 A003 10 A003 10 3 3 3 4 4 4 6 8 S 23733237338 11 11 S 2310523105 4 4 2 5 12 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A001 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE ARCHITECTURAL SITE PLAN SITE SCHEDULE - "Y" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS EXTERIOR MENU 22540 1 MENU BOARD - DT 5 PANEL SQUARE FRAME FREESTANDING - 95X62IN 2415X1575MM - BLACK SB SV SUPPLIER: DT SIGNAGE VENDOR (DSA) INSTALLER: REGIONAL SIGNAGE VENDOR 22542 1 MENU BOARD - DT PRE MENU SQUARE FRAME FREESTANDING - 29X61IN 735X1550MM - BLACK SB SV SUPPLIER: DT SIGNAGE VENDOR (DSA) INSTALLER: REGIONAL SIGNAGE VENDOR 22546 1 MENU BOARD - DT DIGITAL ORDER SCREEN WITH POST - BLACK SB SV SUPPLIER: IT EQUIPMENT VENDOR (ZONES) SCREEN INSTALLER: REGIONAL SIGNAGE VENDOR ELECTRICAL: GC CONNECTS DOS WHIPS & STUB-UPS TO DCB: (NCR) - LOW VOLTAGE FENCE AND RAILING 21486 13 FENCE MESH - 54IN 1370MM LL LL OTHER 10020 1 DT WINDOW SHELF - 48IN 1205MM - SST LL LL 22543 1 DT ORDER POINT CANOPY SQUARE FRAME - BLACK SB SV 23113 3 GROUND GRAPHICS DT ENTRY STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE 23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE 23117 15 GROUND GRAPHICS ARROW STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE 23119 5 GROUND GRAPHICS STOP STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE X1115 4 CONCRETE BOLLARD, FOOTING BY LL GC GC UMBRELLA 12147 3 UMBRELLA - BASE 95LB 43KG - FLAT BLACK MT0028 SB SB 20073 3 UMBRELLA - WITHOUT VALANCE - 6FT 183CM - GREEN CANVAS WITH WORDMARK F0056 SB SB SIGNAGE SCHEDULE - "S" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS SIGNAGE - DISK 22606 3 SIGN - DISK SF ILLUMINATED FLUSH MOUNTED EVOLVED - 72IN 1830MM SB GC SIGNAGE - DRIVE THRU 22544 1 SIGN - DT CLEARANCE BAR SQUARE FRAME FREESTANDING - BLACK AND DARK GREEN SB GC 23074 1 part SIGN DIR EXIT ONLY ILLUM DS EXG FDN - 44IN SB GC 23105 1 SIGN - DT DIRECTIONAL SIREN WITH ARROW ILLUM DS - NEW FOUNDATION - 44IN 1120MM SB GC 23733 1 SIGN - DT DIRECTIONAL SIREN NON-ILLUM DS - NEW FOUNDATION - 44IN 1120MM SB GC 23747 1 SIGN - MONUMENT ILLUM DS - 60IN 1425MM SB GC SIGNAGE - OTHER 21297 1 SIGN - 5 MINUTE PARKING SB GC POST, IF REQUIRED, PROVIDED BY OTHERS Scale: 1/16" = 1'-0"1 SITE PLAN N Revision Schedule Rev Date By Description ALL SITE WORK, HARDSCAPE, SIGNAGE FOOTINGS, AND BUILDING BY LL. SIGNAGE INSTALLED BY GC OR VENDOR UNDER SEPERATE PERMIT. Y 23113231137 2' - 2 1 / 2 " 1' - 4 3/4" 1' - 9 1/2" S 2254422544 Y X1115X1115 6 S 2374723747 4 6 ' - 4 1 / 2 " 9' - 10 " 1 1 2 A003 7 A003 1 12 33' - 9 1/4"8' - 1 3/4" Y 2254322543 Y 2254022540 8 9 12 Y 2254222542 1012 A004 2 A005 1 1 13 EQ EQ 12' - 1" 2 Y X1115X1115 S 2254622546 Y 2311523115 Y 2311923119 S 2307423074 57 7 3 EQ EQ 11 13 20 ' - 9 " 6' - 11 1 / 4 " 5' - 0 3 / 4 " 1 1 1 1 5" 2 A501 9 Y X1115X1115 12 A003 10 1.LANDSCAPE AREA BY LL 2. 6” CONCRETE CURB BY LL 3.CANOPY (ABOVE) BY LL. 4.MONUMENT SIGN. 5.DT DIRECTIONAL EXIT/THANK YOU SIGN. 6.CLEARANCE BAR. 7.WAYFINDING PAVEMENT GRAPHICS BY LL. 8.DIGITAL ORDER SCREEN WITH CANOPY. 9.5-PANEL MENU BOARD BY SIGNAGE VENDOR. 10.DT PRE-MENU. 11.LL INSTALLED DETECTOR LOOP. 12.CONCRETE BOLLARD. 13.REINFORCED CONCRETE DRIVE-THRU LANE BY LL. A.REFER TO EXTERIOR ELEVATIONS ON SHEET A201 FOR BUILDING SIGNAGE LOCATION AND DESIGN ID. REFER TO ELECTRICAL PLANS FOR ELECTRICAL REQUIREMENTS. B. LANDSCAPING TO BE PROVIDED PER ZONING CODE AND SUSTAINABILITY REQUIREMENTS. C. DRIVE-THRU EQUIPMENT INCLUDING VEHICLE DETECTION LOOP, WIRELESS COMMUNICATION AND MONITORS SHALL BE COORDINATED BY STARBUCKS CONSTRUCTION MANAGER. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. D. PROVIDE 6" (150MM) THICK CONCRETE PAVING THE LENGTH OF THE DRIVE-THRU LANE, EXTENT TO INCLUDE DRIVE-THRU ENTRY POINT THROUGH WINDOW STANDING PAD. E. GENERAL CONTRACTOR TO APPLY CONCRETE SEALER TO ALL EXTERIOR CONCRETE PATIO AND WALKWAY SURFACES. F.GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION. G.PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT TRANSITION FROM SIDEWALK TO DRIVE AISLE. H.ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS. I.REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK. J.SCRAPE AND REPAINT ALL EXISTING PAINTED SITE FEATURES, INCLUDING, BUT NOT LIMITED TO CURBS, BOLLARDS, RAILINGS AND SITE LIGHTING BASES. K.SEE SHEET A003-A006 FOR ARCHITECTURAL SITE DETAILS. L.ALL SITE FOOTINGS ARE TO BE PROVIDED BY LL. LL TO INSTALL FOOTINGS ONLY PER APPROVED SIGN STRUCTURAL ENGINEERING PLANS. KEYED NOTES GENERAL NOTES LANDSCAPE AREA BY LL LEGEND NEW 6" (150MM) CONCRETE CURB BY LL NEW CONCRETE WALKWAY BY LL CONCRETE DRIVE THRU LANE BY LL SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A002 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE ENLARGED SITE PLANS Scale: 1/4" = 1'-0"3 ENLARGED PLAN - DT ENTRY Scale: 1/4" = 1'-0"1 ENLARGED PLAN - DT ORDER POINT Scale: 1/4" = 1'-0"2 ENLARGED PLAN - DT EXIT N ALL SITE WORK, HARDSCAPE, SIGNAGE FOOTINGS, AND BUILDING BY LL. SIGNAGE INSTALLED BY GC OR VENDOR UNDER SEPERATE PERMIT. Revision Schedule Rev Date By Description SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. MIN. 1' - 9" 6" AVG. ROAD BED CURB AND GRADE MAY VARY PER LOCATION 4 x 4 x .25w SQUARE STEEL TUBE NATURAL FINISH OR ENGINEERED FILL BASE PLATE NON- STRUCTURAL BASE COVER 1 1 / 2 " POST-INSTALLED ANCHORS NOT PERMITTED DUE TO CLOSE SPACING OF ANCHOR BOLTS 8' - 6 " ( M U S T B E M A I N T A I N E D ) 4" 7' - 11 3/4" . 8' - 2 1/2" (BTM. OF BASE PLATE TO TOP OF STEEL TUBE) SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER ALL ANCHORS TO BE PROVIDED BY G.C. (4) ANCHOR BOLTS BASE OUTLINE 8" 8" 8" 8"8"8" 2' - 0" 2' - 0 " ELEVATION VIEW 3 1 / 2 " 1" ANCHOR BOLT (TYP. 1 OF 4) HIGH STRENGTH NON-SHRINKING GROUT PLAN VIEW 2"8"2" 1' - 0 " 1' - 0" 12" X 12" X 3/4" STEEL BASE PLATE 4" X 4" X 0.25" SQUARE STEEL TUBE POST WELDED TO BASE THRU HOLE FOR MOUNTING (TYP.) 2" 8" 2" 4" 4" 4"4" SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER TACK NUT TO ROD 1/2" HEAVY HEX NUT WITH WASHER (4) 1/2" DIA. A36 THREADED HOT DIPPED GALVANIZED THREADED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 1/2" HEAVY HEX NUTS & WASHER - GALVANIZED SEE GROUND FTG. DETAIL FOR ROD LENGTH CENTER ANCHOR ROD PATTERN IN FOUNDATION 3/ 4 " 3/ 4 " 7" 1"6"1" 8" 4"4" 3 1 / 2 " 3 1 / 2 " 6" 3 5/8" DIAMETER HOLE 11/16" DIAMETER BOLT HOLE (TYP. 1 OF 4) 1/2" STEEL PLATE CONDUIT STUB-UP 5 1 / 2 " SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER (4) ANCHOR BOLTS ALL ANCHORS TO BE PROVIDED BY LL CONDUIT STUB-UP 3" ABOVE FOOTING STEEL BASE PLATE OUTLINE ROUTE CONDUIT PER ELECTRICAL SITE PLAN 2' - 0" DIA. 9"3"3"9" 9 1 / 4 " 9 1 / 4 " 1' - 0 " 1' - 0 " 2 3 / 4 " 2 3 / 4 " 6" FRONT ELEVATION SIDE ELEVATION NATURAL GRADE OR ENGINEERED FILL CONDUIT SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. 3' - 0" 2" A N C H O R B O L T P R O J E C T I O N 1 1 / 2 " 8" 2" 6' - 0 " 4 1/2"6"4 1/2" 1' - 3" 2" 2" 2 1 / 4 " 7/ 8 " 7/ 8 " 4" 7 1/2"7 1/2" 3/8" STEEL PLATE 5/8" DIA. BOLT HOLE (TYP. 1 OF 4) 1 1/4" DIA. HOLE FOR CONDUIT STUB-UP SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER (4) ANCHOR BOLTS ALL ANCHORS TO BE PROVIDED BY G.C. CONDUIT STUB-UP OFFSET 3" ABOVE FOOTING STEEL BASE PLATE OUTLINE ROUTE CONDUIT PER ELECTRICAL SITE PLAN 2' - 0" DIA. 9"3"3"9" 10 7 / 8 " 10 7 / 8 " 1' - 0 " 1' - 0 " 1 1 / 8 " 1 1 / 8 " FRONT ELEVATION NATURAL GRADE OR ENGINEERED FILL CONDUIT SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. 3' - 8 " M A X . 1' - 8" 2" 3' - 8 " 3' - 8 " SIDE ELEVATION 2" A N C H O R B O L T P R O J E C T I O N 1 1 / 2 " 4" SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A003 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE SITE DETAILS Scale: 1/2" = 1'-0"1 DTE CLEARANCE BAR GROUND FOOTING Scale: 3/4" = 1'-0"2 DTE CLEARANCE BAR BOLT PATTERN (TOP VIEW) Scale: 1 1/2" = 1'-0"3 DTE CLEARANCE BAR BASE PLATE Scale: 3" = 1'-0"4 DTE CLEARANCE BAR ANCHOR ROD ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONSAND ENGINEERED DETAILS. Scale: 3" = 1'-0"5 DTE MONUMENT BASE PLATE Scale: 1 1/2" = 1'-0"6 DTE MONUMENT SIGNAGE BOLT PATTERN (TOP VIEW) Scale: 3/4" = 1'-0"7 DTE MONUMENT SIGNAGE ELEVATION Scale: 3" = 1'-0"8 DTE DIRECTIONAL SIGNAGE BASE PLATE Scale: 1 1/2" = 1'-0"9 DTE DIRECTIONAL SIGNAGE BOLT PATTERN (TOP VIEW) Scale: 3/4" = 1'-0"10 DTE DIRECTIONAL SIGNAGE GROUND FOOTING Revision Schedule Rev Date By Description 4 1/2"4"4"4 1/2" 1' - 5" 2" 4" 4" 2" 1' - 0 " FRONT EDGE FACING DRIVE THRU LANE 3/4" STEEL BASE PLATE THRU HOLE FOR MOUNTING (TYP.) 2 1/2" SQUARE X 1/4" PLATE WASHER (TYP. 1 OF 4) 6 1/2"4"6 1/2" ANCHOR BOLT (TYP 1 OF 4) 6" X 3" X 0.1875" STEEL POST WELDED TO BASE PLATE MI N I M U M C L E A R A N C E 4' - 6 " ( 1 3 7 2 M M ) 30° MENU BOARD CONCRETE FOOTING BY LL EDGE OF CONCRETE CURB (1) CONDUIT, ROUTE TO ELECTRICAL PANEL 40'-0" (12M) TO CENTERLINE OF ORDER POINT MENU BOARD (1372 MM) 4' - 6" (3 0 5 M M ) 1' - 0 " CONCRETE BOLLARD ON CONCRETE FOOTING PROVIDED BY LL (9 1 4 M M ) 3' - 0 " SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER 2' - 0" DIA. 8"8"8" 4"4" 8" 8" 8" ALL ANCHORS TO BE PROVIDED BY G.C. CONDUIT STUB-UP 3" ABOVE FOOTING ANCHOR BOLT (TYP. 1 OF 4) BASE OUTLINE DRIVE LANE FACE THIS SIDE ROUTE CONDUIT PER ELECTRICAL SITE PLAN 4" 4" SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER TACK NUT TO ROD 1/2" HEAVY HEX NUT WITH WASHER (4) 1/2" DIA. X 9" LENGTH A36 THREADED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 1/2" - 13 HEAVY HEX NUTS & WASHER - GALVANIZED SEE GROUND FOOTING DETAIL FOR ROD LENGTH CENTER ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS: HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 4" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (4) REQUIRED 8 3/4" SIDE ELEVATION SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. FRONT ELEVATION 2' - 5 1/8" NON-STRUCTURAL BASE COVER HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED STEEL MOUNTING BASE WELDED TO POST NATURAL GRADE OR ENGINEERED FILL 6" MIN.. 1 1 / 2 " 1' - 7 1 / 2 " 3' - 5 3 / 8 " 8" 8" 8" 4" 4"2' - 0 " 7"8"1' - 1"8"1' - 9"8"7" 6' - 0" 2' - 5"2"2"2"3' - 1" ALL ANCHORS TO BE PROVIDED BY G.C. ANCHOR BOLT (TYP.): (4) AT EACH CANOPY BASE PLATE (4) AT DOS BASE PLATE BASE COVER OUTLINE OUTLINE OF CANOPY BASE PLATE (TYP. 1 OF 2)) ALL CONDUIT STUB-UPS TO BE 3" ABOVE FOOTINGEDGE OF CONCRETE FOOTING ROUTE CONDUIT PER ELECTRICAL SITE PLAN OUTLINE OF DOS POST BASE PLATE DOS STUB-UPS DR I V E T H R U P O S S T U B - U P DR I V E T H R U P O S S T U B - U P EL E C T R I C A L S T U B - U P DE T E C T O R L O O P S T U B - U P 1' - 0 " 1' - 0 " DR I V E T H R U C U R B 2' - 3 " T O F A C E O F 4"4"CANOPY LIGHTING 1" DIA. STUB-UP; ROUTE TO SIGNAGE POWER 4" 1" D I A 1" D I A 1" D I A 3/ 4 " D I A ELECTRICAL TO BE INDIVIDUAL BRANCH CIRCUIT IN DEDICATED CONDUIT TO BOH ELECTRICAL PANEL BY G.C. FRONT ELEVATION 1 1 / 2 " 10 ' - 3 7 / 8 " 4' - 6" 5/8" HOT DIPPED GALVANIZED LEVELING NUTS (12) REQUIRED STEEL BASE PLATE WELDED TO STEEL POSTS BY MFR. NATURAL GRADE OR ENGINEERED FILL NON-STRUCTURAL BASE COVER DOS AND SPEAKER CANOPY ABOVE 2" C L R . 1' - 5"6' - 7 7/8" 9' - 1 0 " SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER SIDE ELEVATION 10 ' - 3 7 / 8 " LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER TACK NUT TO ROD 5/8" HEAVY HEX NUT WITH WASHER (4) 5/8" DIA. A36 THREADED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 1/2" HEAVY HEX NUTS & WASHER - GALVANIZED SEE GROUND FOOTING DETAIL FOR ROD LENGTH SEE SEPARATE DETAIL FOR ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS: HILTI 5/8" DIA. HVU ADHESIVE CAPSULES AT 9" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (12) REQUIRED 2"8"2" 4" 8" 2" 1' - 0" 1' - 2 " 4" X 4" X 0.25" STEEL TUBE POST WELDED TO STEEL BASE PLATE FRONT EDGE FACING DRIVE THRU LANE THRU HOLE FOR MOUNTING (TYP.) ANCHOR BOLT (TYP 1 OF 4) CUT-OUT 1 3/8" BASE PLATE 2 5 / 8 " 1 3 / 8 " 4"4" SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A004 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE SITE DETAILS ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONSAND ENGINEERED DETAILS. Scale: 1 1/2" = 1'-0"1 DTE PRE-MENU BASE PLATE Scale: 1/2" = 1'-0"2 PRE-MENU 30 DEG Scale: 1 1/2" = 1'-0"3 DTE PRE-MENU BOLT PATTERN (TOP VIEW) Scale: 3" = 1'-0"4 DTE PRE-MENU ANCHOR ROD Scale: 3/8" = 1'-0"5 DTE PRE-MENU ELEVATION Scale: 1" = 1'-0"6 DTE ORDER POINT CANOPY BOLT PATTERN (TOP VIEW) Scale: 3/8" = 1'-0"8 DTE DOS CANOPY ELEVATION Scale: 3" = 1'-0"7 DTE DOS CANOPY ANCHOR ROD Scale: 1" = 1'-0"9 DTE DOS CANOPY BASE PLATE Revision Schedule Rev Date By Description (3 0 5 M M ) 1' - 0 " (730MM) 2' - 5"4' - 2" (1270MM)6' - 1" (1854MM) 3' - 3 " ( 9 9 1 M M ) 15°(1) CONDUIT, ROUTE TO ELECTRICAL PANEL CONCRETE FOOTING BY LL MENU BOARD MI N . C L R . A R E A 4' - 1 " ( 1 2 4 5 M M ) 15' - 2" (4623MM) MIN. CLR. AREA MI N . C L R . 1' - 0 " ( 3 0 5 M M ) DIGITAL ORDER SCREEN (DOS) AND SPEAKER LL PROVIDED DETECTOR LOOP EDGE CENTERED ON DOS POST 2" (51MM) BELOW FINAL GRADE IN CONDUIT OR SAWCUT. VERIFY NO METAL IN SLAB WITHIN 36" (915MM) OF LOOP. CONDUIT TO DOS POST EDGE OF LL PROVIDED CONCRETE FOOTING (DATUM POINTS REPRESENT CENTER OF (2) CANOPY BASE PLATES) EDGE OF EXISTING CONCRETE CURB (1) CONDUIT, STUB UP FOR CANOPY LIGHTING, ROUTE TO SIGNAGE POWEROUTLINE OF CANOPY ABOVE CANOPY POST (TYP. 1 OF 2) (2) CONDUIT FROM DOS POST, ROUTE TO DRIVE THRU WINDOW (1) CONDUIT FROM DOS POST, ROUTE TO ELECTRICAL PANEL CONCRETE BOLLARD ON CONCRETE FOOTING 36" x 36" (915MM) MIN. CLEAR AREA ACCESS DOS POST (6 8 6 M M ) 2' - 3 " SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. FRONT ELEVATION NON-STRUCTURAL BASE COVER HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED STEEL MOUNTING BASE PLATE WELDED TO STEEL POST SIDE ELEVATION NATURAL GRADE OR ENGINEERED FILL 1 1 / 2 " 8" MIN.. CONDUIT 3' - 6 3 / 4 " 1' - 6 3 / 4 " 7' - 10 1/2"1' - 1 1/2" SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER SEE SEPARATE DETAIL FOR ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS: HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 8" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (4) REQUIRED TACK NUT TO ROD 1/2" HEAVY HEX NUT WITH WASHER (4) 1/2" DIA. A36 THREADED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 1/2" HEAVY HEX NUTS & WASHER - GALVANIZED SEE GROUND FOOTING DETAIL FOR ROD LENGTH 8" X 4" X 0.1875" STEEL TUBE POST WELDED TO BASE PLATE 3" 8" 3" 1' - 6" 7"4"7" 7" 7" 1' - 2 " THRU HOLE FOR MOUNTING (TYP.) 2 1/2" SQUARE X 1/4" PLATE WASHER (TYP. 1 OF 4)) 3/4" STEEL BASE PLATE FRONT EDGE FACING DRIVE THRU LANE 2"5"5"2"2"2" 5"2"4"2"5" ANCHOR BOLT (TYP 1 OF 4) SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER ALL ANCHORS TO BE PROVIDED BY G.C. CONDUIT STUB-UP 3" ABOVE FOOTING (4) ANCHOR BOLTS BASE PLATE OUTLINE FRONT EDGE OF DRIVE LANE SIDE ROUTE CONDUIT PER ELECTRICAL SITE PLAN 11"8"11" 4" 4" 11 " 8" 11 " 1' - 3"1' - 3" 2' - 6" DIA. ALL ANCHORS TO BE PROVIDED BY G.C. SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER ROUTE CONDUIT PER ELECTRICAL SITE PLAN (4) ANCHOR BOLTS BASE OUTLINE DRIVE THRU LANE FACE THIS SIDE CONDUIT STUB-UPS 3" ABOVE FOOTING DE T E C T O R L O O P S T U B - U P DR I V E T H R U P O S S T U B - U P DR I V E T H R U P O S S T U B - U P EL E C T R I C A L S T U B - U P 2' - 0" DIA. 8"4"4"8" 8" 4" 4" 8" 2"1"1"2" 1" D I A 1" D I A 1" D I A 3/ 4 " D I A ELECTRICAL TO BE INDIVIDUAL BRANCH CIRCUIT IN DEDICATED CONDUIT TO BOH ELECTRICAL PANEL ALL CONDUIT STUB-UPS TO BE 3" ABOVE FOOTING SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY. NON-STRUCTURAL BASE COVER FRONT ELEVATION SIDE ELEVATION HOT DIPPED GALVANIZED LEVELING NUTS (4) REQUIRED STEEL MOUNTING BASE WELDED TO POST NATURAL GRADE OR ENGINEERED FILL 1 1 / 2 " 4' - 1 3 / 4 " 1' - 9 3 / 4 " 2' - 5 1/4"8 1/4"9 3/8" 0.625" STEEL BASE PLATE 1' - 2 1/4" 3 1/8"EQ EQ 3 1/8" 2 1 / 4 " 2 1 / 4 " EQ EQ1' - 0 1 / 2 " THRU HOLES FOR MOUNTING (TYP.) 9.843" X 3.973 X 3/16" STEEL POST WELDED TO STEEL BASE PLATE FRONT EDGE FACING DT LANE 2 1/2" SQUARE X 1/4" PLATE WASHERS (TYP. 1 OF 4) ANCHOR BOLT (TYP 1 OF 4)SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER TACK NUT TO ROD 1/2" HEAVY HEX NUT WITH WASHER (4) 1/2" DIA. X 9" LENGTH A36 THREADED HOT DIPPED GALVANIZED ANCHOR RODS WITH GALVANIZED HARDWARE (3) 1/2" - 13 HEAVY HEX NUTS & WASHER - GALVANIZED SEE GROUNG FOOTING DETAIL FOR ROD LENGTH CENTER ANCHOR ROD PATTERN IN FOUNDATION ALTERNATE ADHESIVE POST-INSTALLED ANCHORS: HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 4" EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE. (4) REQUIRED EM B E D M E N T 2' - 6 " M I N 2' - 6 " 6" (150mm) STEEL PIPE FILLED WITH CONCRETE PAVING OR CONCRETE SLAB EXPANSION JOINT (SEALANT) CONCRETE FOOTING BY GC CONCRETE DOME CONCRETE FILLED DIAMETER 1' - 0" 3' - 0 " SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A005 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE SITE DETAILS ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONSAND ENGINEERED DETAILS. Scale: 1/2" = 1'-0"1 DTE - 5 PANEL 15º DT MENU BOARD, DIGITAL ORDER SCREEN WITH CANOPY Scale: 3/8" = 1'-0"2 DT 5-PANEL MENU BOARD GROUND FOOTING Scale: 3" = 1'-0"4 DTE 5-PANEL MENU BOARD ANCHOR ROD Scale: 1 1/2" = 1'-0"5 DTE 5-PANEL MENU BOARD BASE PLATE Scale: 1 1/2" = 1'-0"6 DTE 5-PANEL MENU BOARD BOLT PATTERN (TOP VIEW) Scale: 1 1/2" = 1'-0"7 DTE DOS POST BOLT PATTERN (TOP VIEW) Scale: 3/8" = 1'-0"8 DTE DOS POST ELEVATION Scale: 1 1/2" = 1'-0"9 DTE DOS POST BASE PLATE Scale: 3" = 1'-0"10 DTE DOS POST ANCHOR ROD Revision Schedule Rev Date By Description Scale: 3/4" = 1'-0"3 CONCRETE BOLLARD 1.OUTLINE OF BAR PER CASEWORK MANUFACTURER. 2.ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM CLEARANCE AS REQUIRED BY CODE. 3.ALIGN FACE OF FINISHED WALL. 4.SHELF FOR WATER HEATER ABOVE. REFER TO INTERIOR ELEVATION FOR HEIGHT AND DETAILS FOR CONSTRUCTION OF PLATFORM AND SUPPORTING ASSEMBLY. SEE 6/A501 FOR DETAIL. 5.FUR OUT INTERIOR FACE OF WALL. KEYED NOTES GENERAL NOTES A.GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING, OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT AND/OR SIGNAGE. C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE CODE, REMOVE AND REPLACE WITH ACCESSIBLE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN 1:12. D.ALL DIMENSIONS ARE TO FINISHED FACE UNLESS SHOWN OR NOTED OTHERWISE. E.. INSTALL MOISTURE RESISTANT GREEN BOARD ON BACKBAR WALL PER PROJECT MANUAL. F. ALL DOORS SHALL BE 32 ” (815MM) MINIMUM CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION UNLESS OTHERWISE NOTED. G.SEE SHEET A601 FOR EXTERIOR DOOR AND WINDOW SCHEDULES. H.STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS AND GC TO INSTALL. I. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS AND/OR CODE REQUIREMENTS. J.PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE CITY. K.SEE STRUCTURAL FOR KNEE WALL BRACING. L.SEE SHEET A501 FOR BUILDING DETAILS. M.REFER TO SHEET I104 FOR FLOOR FINISHES. NEW PARTIAL HEIGHT WALL NEW FULL HEIGHT WALL EXISTING WALL GENERAL LEGEND WALL BLOCKING CALL-OUTXX XX WALL SHEATHING CALL-OUT WALL SHEATHING KEY SYMBOL DESCRIPTION 5/8" GYP. WALL BOARD (FULL WALL HEIGHT)A 5/8" GYP. WALL BOARD (TERMINATE AT 6" (150MM) ABOVE CEILING)B C 5/8" CEMENTITIOUS BACKER BOARD (TERMINATE AT 6" (150MM) ABOVE CEILING) D 5/8" GREENBOARD (TERMINATE AT FINISH TRANSITION AS SHOWN ON INTERIOR ELEVATION W/ 5/8" GYP. WALL BOARD ABOVE (FULL WALL HEIGHT)). E 5/8" PURPLE BOARD (TERMINATE AT 6" (150MM) ABOVE CEILING) 5/8" PLYWOOD (TERMINATE AT 6" (150MM) ABOVE CEILING) INDICATES SHEATHING TRANSITION F D D D D C C D D D D D D B EE E EB D F D D D D DD D D D D D D F D D D D D G G GG H 2' - 4"4' - 0"6 3/4"10 3/4"20' - 9 3/4"10 3/4" 3' - 6 " 6' - 1 1 / 2 " 7' - 9 1 / 4 " 8' - 5"3' - 6 1/4"2' - 10" 8' - 0 1/2"4' - 8 3/4"9' - 11 3/4"2' - 8 1/2" 9' - 3" 3' - 5 1 / 4 " 6' - 6 3 / 4 " 3' - 1 0 1 / 4 " 2' - 0 1 / 2 " 1' - 3 1/4"14' - 7 1/2" 5' - 1" 7 1 / 4 " 2' - 1 3 / 4 " Q L F F F F B A M K C E D P P S 3-F-A 6-T-N 4-F-A 3-F-A 4-F-A4-F-A 3-F-A 3-F-A 4-F-N 2-F-N 4-F-N 3-T-A 6-T-N 3-T-N 6-T-N 6-T-N D 10190 01 D 10190 02 D EXTG E2 D EXTG E1 5 3 3 24 5 5 5 5 4 1 1 1 CAFE WORKROOM RESTROOM VEST.RESTROOM 1 RESTROOM 2 ENGINE 2-F-N 6' - 5 1 / 4 " 2-F-N 3-P-N 3 33 3 F F D D F E E EEE 2' - 7 1/4" 3' - 0" 2' - 0 1 / 2 " 2' - 6 1 / 2 " 10 3/4" 2' - 6 3 / 4 " 8' - 0 " 8' - 3 " B 7' - 6 3 / 4 " 4 3 / 4 " 7 1/4" 5 DRIVE-THRU A501 4 A501 6 2-T-N 2-T-N2-T-N E 1-F-N 1-F-N 1-F-N 555 3 WALL BLOCKING KEY SYMBOL ITEM 128 LBS (58 KG) WEIGHT 36" TO 40" (915MM TO 1015MM) HEIGHT A.F.F. 30" (760MM) BEHIND SINKA APPROX. WIDTH SHELVES ABOVE COMPARTMENT SINK 200 LBS (91 KG) 48" TO 76" (1220MM TO 1930MM) 96" (2440MM) CENTERED ABOVE COMPARTMENT SINKB C BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR SHELVES AT MANAGER'S DESK 300 LBS (136 KG) 32" TO 96" (810MM TO 2440MM) 48" (1220MM) 3/4 (19MM) ACX PLYWOOD, CENTERED ON SHELVES D EQUIPMENT RACK AT MANAGER'S DESK 300 LBS (136 KG) 44" TO 96" (1120MM TO 2440MM) 28" (710MM) 3/4 (19MM) ACX PLYWOOD, CENTERED ON RACKE F BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR. IN- WALL BLOCKING PREFERRED, HOWEVER EXISTING FRP FINISHED WALL MAY RECEIVE SURFACE MOUNTED, PAINTED WHITE. 30" TO 36" (760MM TO 915MM) 60" (1525MM) AROUND WATER CLOSETG200 LBS (91 KG) COMMERCIAL INSTALLATION REQUIRES CONCEALED ARM CARRIER. REFER TO MFR'S SPECIFICATION.H 200 LBS (91 KG) BLOCKING SPECIFICATION FOR FRENCH CLEATING SYSTEM. REFER TO DETAILS.I BLOCKING SPECIFICATION FOR CBE METAL SHELVES. REFER TO VENDOR'S SPECIFICATION AND DETAILS.K COORDINATE LOCATION AND EXTENT WITH PENTAIRLTBD BY VENDOR ALL ARTWORK, FIXTURES, ACCESSORIES AND CASEWORK FABRICATIONS NOT OTHERWISE NOTED GC TO PROVIDE WALL BLOCKING AS REQUIRED FOR ALL ITEMS FOR A COMPLETE AND SECURE INSTALLATION. EXTEND BLOCKING 8" (205MM) BEYOND ON EACH SIDE OF EACH ITEM. TBD BY VENDOR (VARIES) WORKROOM HAND SINK UPPER WIRE SHELVES RESTROOM GRAB BARS RESTROOM HAND SINK METRO SHELVES MILLWORK BOXES UPPER CBE SHELVING WATER FILTRATION SYSTEM 60" TO 72" (1525MM TO 1830MM)M 300 LBS (136 KG) LOCKERS (3/4" PLYWOOD) 18" (455MM) PAST LOCKERS EA. SIDE 4'-0" TO 6'-6" N 100 LBSDRIVE THRU COMMUNICATIONS EQUIPMENT 4'-0" BEHIND POS AND BARISTA AT DRIVE THRU WINDOW 3'-4" TO 5'-2" P 250 LBSVERTICAL GRAB BAR BETWEEN STUDS BEHIND GRAB BAR Q S ORDER STATUS BOARD (OSB)BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A101 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE BUILDING FLOOR PLAN Scale: 1/4" = 1'-0"1 FLOOR PLAN N Revision Schedule Rev Date By Description INTERIOR WALL SCHEDULE TAG DESCRIPTION INSULATION NOTES 1-F-N 1 1/2" 20 GA STUD FURRING WALL NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 2-F-N 3 5/8" 20 GA STUD FURRING WALL NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 2-T-N 3 5/8" 20 GA STUD FURRING WALL NONE TERMINATE 6" ABOVE CEILING. SEE PLAN FOR WALL SHEATHING. 3-F-A 3 5/8" 20 GA STUDS @ 16" O.C.ACOUSTIC FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 3-P-N 3 5/8" 16 GA STUDS @ 16" O.C.NONE PARTIAL HT. WALL W/ RCKW RIGID CONNECTORS AT FLOOR. SEE ELEVATIONS FOR WALL HT. SEE PLAN FOR WALL SHEATHING. 3-T-A 3 5/8" 20 GA STUDS @ 16" O.C.ACOUSTIC TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE. SEE PLAN FOR WALL SHEATHING. 3-T-N 3 5/8" 16 GA STUDS @ 16" O.C.NONE TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE. SHEATHING ONE SIDE. SEE PLAN FOR WALL SHEATHING. 4-F-A 6" 20 GA STUDS @ 16" O.C.ACOUSTIC FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 4-F-N 6" 20 GA STUDS @ 16" O.C.NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING. 6-T-N 6" 20 GA STUD FURRING WALL NONE TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE. SHEATHING ONE SIDE. SEE PLAN FOR WALL SHEATHING. 1. ELECTRICAL STUB-UP LOCATION. SEE ELECTRICAL SHEETS. 2.PLUMBING STUB-UP LOCATION. SEE PLUMBING SHEETS 3.FLOOR SINK LOCATION. SEE PLUMBING SHEETS. 4.FLOOR DRAIN LOCATION. SEE PLUMBING SHEETS. 5.APPROXIMATE LOCATION OF LL PROVIDED GI. 6.MOP SINK WASTE. 7.WATER CLOSET WASTE. 8.BANQUETTES WITH POWER. A. ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL PLACEMENT. B. FLOOR SINK: REFER TO CUT SHEETS FOR COMPONENT SPECIFICATIONS AND CUTOUT REQUIREMENTS. C. WASTE LINE PENETRATIONS: REFER TO PLUMBING PLANS FOR INDIVIDUAL LINE LOCATIONS. D. STUB-UP PENETRATIONS: REFER TO ELECTRICAL AND PLUMBING PLANS FOR INDIVIDUAL STUB-UP LOCATIONS. E. TOILET FLOOR PENETRATION: REFER TO CUT SHEETS FOR STUB-UP LOCATION RELATIVE TO FINISHED WALL. F. PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED PER CONDITIONS. G. TRENCHING OUTLINE FOR GUIDELINE USE ONLY. GENERAL CONTRACTOR TO COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE ACTUAL LAYOUT. H.REFER TO SHEET I105 FOR FLOOR FINISHES. KEYED NOTES GENERAL NOTES EXISTING WALL LEGEND DATUM POINT FLOOR DRAIN FLOOR CLEAN-OUT FLOOR SINK ADJACENT TENANT (NO WORK) 16' - 0 1/4" 17' - 7 3/4" 21' - 5 3/4" 21' - 7 1/4" 27' - 8 1/4" 2' - 9 3 / 4 " 1' - 1 0 3 / 4 " 4' - 5 1 / 2 " 17 ' - 1 1 / 2 " 13' - 11" 1' - 6" 1' - 2 1 / 4 " 1' - 3 3 / 4 " 13' - 3 1/4" 14' - 3 1/2" 38' - 8 3/4" 2' - 0 1 / 2 " 9' - 5 " P 10726 P 10294 P 10726 P 10294 P 10726 P 10726 P 10294 P 10726 P 10294 7 7 6 3 3 3 3 3 3 1 1 2 8 3' - 9 1 / 4 " 11 ' - 9 1 / 2 " P 10594 P 105944 4 3' - 8 1/4" 11' - 9 1/4" P 10594 4 10' - 11 1/4" 2' - 3 1 / 4 " P 10294 P 107263 44' - 6" 2' - 1 1 3 / 4 " 37' - 9" 8' - 1 1 / 2 " P 10726 P 10294 3 CAFE RESTROOM VEST. RESTROOM 1 RESTROOM 2 WORKROOM ENGINE A501 2 A501 3 A501 1 DRIVE-THRU 5 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A102 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE BUILDING FLOOR PENETRATION PLAN Scale: 1/4" = 1'-0"1 FLOOR PENETRATION PLAN N Revision Schedule Rev Date By Description 1.PROVIDE J-BOX FOR BUILDING SIGNAGE. COORDINATE LOCATION WITH SIGNAGE VENDOR SHOP DRAWINGS. 2.PROVIDE SIGNAGE DISCONNECT ON INSIDE FACE OF WALL. 3.3/4" MARINE GRADE PLYWOOD BLOCKING FOR EXTERIOR SIGNAGE. EXTEND BLOCKING 8" (205MM) MIN. BEYOND EDGE OF SIGNAGE. 4.DT WINDOW BY LL. 5.STEEL CANOPY BY LL. 6.EXISTING BUILDING SHELL AND FINISHES BY LL. 7.EXTERIOR SCONCE LIGHTING BY LL. 8.DOWNSPOUT BY LL. A.GENERAL CONTRACTOR TO COORDINATE AND SCHEDULE SIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTOR PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1 WEEK PRIOR TO SCHEDULED DATE OF INSTALLATION. CONSTRUCTION MANAGER TO PROVIDE GENERAL CONTRACTOR WITH SIGNAGE CONTRACTOR CONTACT INFORMATION. B.GENERAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ELECTRICAL CIRCUITS INCLUDING ALL CONDUIT, WIRE, CONNECTIONS AND BREAKER AT PANEL BOARD NECESSARY TO SERVE SIGNAGE. C.GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING OR EQUIVALENT TO SUPPORT SIGNAGE. D.SIGNAGE CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ANY AND ALL ALLOWABLE MONUMENT OR POLE SIGNAGE AND PROVIDE SHOP DRAWING(S) PRIOR TO FABRICATION TO THE STARBUCKS DESIGNER FOR APPROVAL. E. SIGNAGE CONTRACTOR TO INSTALL SIGNAGE IN COMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT. F.SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TO CONSTRUCTION MANAGER AND TO THE GENERAL CONTRACTOR AS NEEDED. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF SHOP DRAWINGS OR INSTALLATION IS IN DISCREPANCY WITH ARCHITECTURAL DRAWINGS. G.GENERAL CONTRACTOR TO CLEAN, PATCH AND REPAIR EXISTING EXTERIOR AS REQUIRED. KEYED NOTES GENERAL NOTES EQEQ EQ EQ S 2260622606123 5 5 5777 7 6 8 Z X19131 EQ EQ EQ EQ S 2260622606 1 2 3 4 5 7 6 8G2387823878 16 ' - 4 1 / 4 " 1' - 2 " EXTENT OF ARTWORK, VIF 49' - 0" PAINTABLE EXTERIOR MURAL8 EQ EQ EQ EQ 1 S 2260622606 7 7 6 23 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A201 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE BUILDING EXTERIOR ELEVATIONS Scale: 3/16" = 1'-0"1 EXTERIOR ELEVATION - NORTH Scale: 3/16" = 1'-0"2 EXTERIOR ELEVATION - EAST Scale: 3/16" = 1'-0"3 EXTERIOR ELEVATION -WEST Revision Schedule Rev Date By Description EQ EQ 7" EQ EQ 3" DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 1 CWF STUB-UP 3/4" LINE 2 CW STUB-UP 3/4" LINE ESPRESSO BAR PLUMBING STUB-UP KEY 1 2 POS DIEWALL NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. 3 3 / 4 " 1 EQ EQ 3" EQ EQ 1' - 9" DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 2 3 3 3 3 3 1 / 2 " ESPRESSO BAR DIEWALL 1 3/4" LAN CONDUIT 2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION 3 3/4" ISOLATED GROUND POWER CONDUIT ESPRESSO BAR ELECTRICAL STUB-UP KEY NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 1 3/4" POWER CONDUIT TO ELECTRICAL PANEL 2 1/2" PHONE TO MANAGER'S DESK 3 1/2" DATA CONDUIT TO MANAGER'S DESK POS ELECTRICAL STUB-UP KEY 4 1/2" SECURITY TO MANAGER'S DESK 5 3/4" LAN CONDUIT TO POS/SAFE 6 3/4" POWER CONDUIT FOR PASTRY CASE POS DIEWALL EQ EQ 3" EQ EQ 1' - 6" 7"1 2 5 634 NOTE:SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. 6 1 / 2 " 11 1 / 2 " 1' - 9 1 / 2 " VA R I E S DR I V E T H R U B U M P D E P T H V A R I E S 1 FINISH FACE OF INTERIOR CORNER AT DRIVE THRU POS WALL DRIVE THRU POS 1 VIDEO CONDUIT FROM DRIVE THRU ORDER POINT(S) AUDIO CONDUIT FROM DRIVE THRU ORDER POINT(S) AND DETECTOR LOOP(S) CONDUIT FROM DT WINDOW2 3 IN-WALL DRIVE THRU CONDUIT STUB-UP KEY EXTERIOR WALL ASSEMBLY 2 3 . .INTERIOR FURRING BOT OF SHELF 5'-10" AFF 5/8" WATER RESISTANT GYP. BD 3/4" PLYWOOD FLOOR SCREWS @ 6" O.C. (2) 362S162-43 STUDS @ 8" O.C. @ WATER HEATER SHELF SIMPSON 'L50' CLIP 2 SIDES W/ (5) #10 SCREWS TYP EA LEG (2) 362S162-43 STUDS @ 8" O.C. @ WATER HEATER SHELF (2) 600S162-43 STUDS @ 8" O.C., ALIGN W/ STUDS 5 A501 7 A501 SEE FLOOR PLAN 2' - 2 " . BOT OF SHELF PER ELEVATION 5/8" WATER RESISTANT GYP. BD 3/4" PLYWOOD FLOOR SCREWS @ 6" O.C. (2) 600S162-43 STUDS @ 8" O.C. @ WATER HEATER SHELF 2' - 2". SEISMIC STRAPPING: 16 GA X 1" WIDE METAL STRAP w/ MIN. (4) #10 SCREWS EA STRAP INTO STUDS A501 8 NOTE: SEISMIC STRAPPING LOCATIONS @ TOP 3RD & BOT 3RD OF WATER HEATER. BOT OF SHELF PER ELEVATION 3/4" PLYWOOD FLOOR WATER RESISTENT GYP BD (2) 600S16-43 BOX BEAM STAINLESS STEEL METAL CORNER GUARD 5/8" WATER RESISTANT GYP. BD AIR CURTAIN AND HEATER SIDE FILTERS (INCLUDED) DRIVE THRU WINDOW PER PLAN (BY LANDLORD) SHELF PER PLAN INTERIOR FINISH GRADE EXTERIOR FINISH GRADE PLAN CU R B 6" ( 1 5 0 M M ) MAX. 1' - 6" (450MM) BOLLARD MI N . C L E A R 5' - 0 " ( 4 6 0 M M ) 10' - 1" (3075MM) MAX CLEAR 9' - 1" (2770MM) MIN. CLEAR 14 " ( 3 5 5 M M ) M A X . 12 " ( 3 0 5 M M ) M I N . CENTERLINE OF DRIVE THRU WINDOW CONCRETE CURB CONCRETE INFILL AT BUMP OUT DRIVE THRU WINDOW AND SHELF PER PLAN DETECTOR LOOP EDGE CENTERED ON DRIVE THRU WINDOW 2" (50MM) BELOW FINAL GRADE IN CONDUIT OR SAWCUT. ROUTE (1) CONDUIT TO DRIVE THRU POS AND TERMINATE NEAR TIMER SIGNAL PROCESSOR (TSP). VERIFY THAT NO METAL IN SLAB WITHIN 36" (915MM) OF LOOP. WINDOW CONFIGURATION PER PLAN BOLLARD ELEVATION DRIVE THRU SHELF PER PLAN (9 1 5 M M ) 3' - 0 " 12 A501 1 3 / 4 " ( 4 5 m m ) (5 0 m m ) 2" ALIGN STAINLESS STEEL ANGLE TO CAP INTERIOR WALL. HEM BOTTOM EDGE SHELF PER ELEVATION EXTERIOR WALL ASSEMBLY PER SHELL BUILDING PERMIT +/ - 2 " ( 5 0 m m ) 3' - 6 " ( 1 0 6 5 m m ) 14" (355mm) MAXIMUM 12" (300mm) MINIMUM ------------------------- HO L D 3' - 0 " ( 9 1 5 m m ) A . F . F . SINGLE PANEL DRIVE-THRU WINDOW ASSEMBLY PER PLAN ATTACH SHELF TO BUILDING EXTERIOR FLUSH TO TOP OF ROUGH OPENING, CENTERED ON WINDOW EXISTING EXTERIOR WALL SYSTEM A501 11 AIR CURTAIN BY LL SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A501 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE BUILDING DETAILS Scale: 1 1/2" = 1'-0"1 PLUMBING STUB-UPS AT ESPRESSO BAR Scale: 1 1/2" = 1'-0"2 ELECTRICAL STUB-UPS AT ESPRESSO BAR Scale: 1 1/2" = 1'-0"3 ELECTRICAL STUB-UPS AT POS Scale: 3/4" = 1'-0"4 DRIVE THRU POS IN-WALL CONDUIT STUB-UPS Scale: 1/2" = 1'-0"5 CROSS SECTION @ WATER HEATER SHELF Scale: 3/4" = 1'-0"6 PLAN @ WATER HEATER SHELF Scale: 1/2" = 1'-0"7 SECTION @ WATER HEATER SHELF Scale: 3" = 1'-0"8 SHELF EDGE DETAIL Revision Schedule Rev Date By Description Scale: 1/2" = 1'-0"10 DRIVE THRU WINDOW AND AIR CURTAIN Scale: 1/4" = 1'-0"9 DTE - DRIVE THRU WINDOW BUMP-OUT Scale: 1 1/2" = 1'-0"11 DRIVE THRU WINDOW SHELF SECTION Scale: 1/2" = 1'-0"12 DRIVE THRU WINDOW SECTION A.STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS. GC TO INSTALL. B.SEE SHEET A101 FOR TAGGED LOCATION OF EXTERIOR DOORS AND WINDOWS. C.EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SIMILAR SPACES. (1016.2 IBC) D.PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS BUILDING SHALL SATISFY THE FOLLOWING (1010.2.9 IBC): a)THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. b)THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG). c)PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE LATCH SIDE. d)PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305. e) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305. E.SPY SCOPE HARDWARE, WHERE INSTALLED SHALL BE CENTERED IN DOOR AT 54" (1370MM) A.F.F. GENERAL NOTES DOOR LEGEND STOREFRONT METAL FRAME DOUBLE (TYPE A) STOREFRONT METAL FRAME SINGLE (TYPE B) SINGLE FLUSH (TYPE 1) EXTERIOR EXTERIORINTERIOR SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 A601 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE WINDOW AND DOOR SCHEDULES & DETAILS DOOR SCHEDULE - "D" DESIGN ID MARK DESCRIPTION WIDTH HEIGHT HARDWARE SET FURN BY INST BY COMMENTS Exterior EXTG E1 DOOR - STOREFRONT METAL FRAME DOUBLE - TYPE A 3' - 0"7' - 0"2-A LL LL PER LL SHELL DRAWINGS; BLACK METAL FRAME MT0028 WITH TEMPERED SAFETY GLAZING EXTG E2 DOOR - STOREFRONT METAL FRAME SINGLE - TYPE B 6' - 0"7' - 0"3-A LL LL PER LL SHELL DRAWINGS; BLACK METAL FRAME MT0028 WITH TEMPERED SAFETY GLAZING 2 Interior 10190 01 DOOR - SINGLE FLUSH - 36IN 3' - 0"7' - 0"6 GC GC PAINT. SEE ELEVATION. FRAME COLOR TO MATCH. 10190 02 DOOR - SINGLE FLUSH - 36IN 3' - 0"7' - 0"6 GC GC PAINT. SEE ELEVATION. FRAME COLOR TO MATCH. 2 1 Sign Vinyl Sign: "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"Seton --- 1 Threshold 325 Half Saddle Threshold National Guard --- 1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626 1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689 1 Operating Trim 108 Door Pull Handle Rockwood 630 1 Securing Devices A08794-003 Adjustable Ring, Mortise Cyl. 516-13/32 Falcon Lock 626 1 Securing Devices C987 7-Pin Mortise Cylinder Housing w/AR Cam Falcon Lock 626 1 Securing Devices C953 7-Pin Rim Cylinder Housing Falcon Lock 626 9 Securing Devices KB632-2 Cut User Key "A" Keyway Falcon Lock ---- 1 Securing Devices KB609-2 Cut Control Key "A" Keyway Falcon Lock --- 2 Securing Devices C607 7-Pin Core Combinated "A" Keyway Falcon Lock 626 1 Securing Devices CD35A-NL-OP Panic Device Von Duprin 628/630 3 Hanging Devices TA2314/MPB91 Hinge MacPro Bearing 4.5 x 4.5 McKinney 630 No.Item Description Manufacturer Finish DOOR HARDWARE SET NO. 2-A - For new single aluminum secondary entry/exit door (50 or more occupancy) 1 Sign Vinyl Sign: "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"Seton --- 1 Threshold 325 Half Saddle Threshold National Guard --- 2 Accessories Door Sweep 18062CNB36 Pemko A 2 Stops and Holders 473 Door Stop w/Hook Rockwood 626 2 Closing Devices 8916 Door Closer 8916 AF89P AL Dorma 689 2 Operating Trim 48 Push Bar x 31 Rockwood 630 2 Operating Trim 108 Door Pull Handle Rockwood 630 2 Securing Devices (active leaf)A08794-003 Adjustable Ring, Mortise Cyl. 5/16-13/32 Falcon Lock 626 2 Securing Devices (active leaf)C987 7-Pin Mortise Cylinder Housing w/AR Cam Falcon Lock 626 9 Securing Devices (active leaf)KB632-2 Cut User Key "A" Keyway Falcon Lock --- 1 Securing Devices (active leaf)KB609-2 Cut Control Key "A" Keyway Falcon Lock --- 2 Securing Devices (active leaf)C607 7-Pin Core Combinated "A" Keyway Falcon Lock 626 1 Securing Devices (inactive leaf)MS1880 Two-Point Flushbolt Adams Rite 626 1 Securing Devices (active leaf)MS1850S Deadbolt Adams RIte 626 6 Hanging Devices TA2314/MPB91 Hinge MacPro Bearing 4.5 x 4.5 McKinney 630 No.Item Description Manufacturer Finish DOOR HARDWARE SET NO. 3-A - For pair aluminum main entry/exit doors (300 or less occupancy) 1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626 3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray 2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630 1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689 1 Securing Devices PB5425LN Lock, Shallow Coin Turn, Privacy PB5425LN-693-497 1-3/4 Yale Lock 626 3 Hanging Items TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626 No.Item Description Manufacturer Finish DOOR HARDWARE SET NO. 6 - For restroom door with lever and privacy lock Revision Schedule Rev Date By Description 1. INSTALL EXTERIOR FURNITURE THROUGHOUT AS SHOWN. 2.INSTALL CAFE FURNITURE THROUGHOUT AS SHOWN. 3.NOT USED. 4.CONDIMENT CART. SEE INTERIOR FINISH ELEVATIONS. 5.PLACE MERCHANDISE FIXTURES PER PLAN. 6.LOCATION OF FIRE EXTINGUISHER. 7.SECURE LOCKERS TO WALL. 8. VENDOR TO INSTALL WATER FILTRATION SYSTEM PER MANUFACTURER'S REQUIREMENTS. G.C. TO PROVIDE PLUMBING AND ELECTRICAL REQUIREMENTS. 9.WATER HEATER LOCATED ABOVE. SEE PLUMBING DRAWINGS. 10.MANAGERS DESK. SEE MANAGER'S DESK/EQUIPMENT RACK ELECTRICAL DETAIL FOR ADDITIONAL INFORMATION. A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR LIST OF APPROVED START UP CONTRACTORS, CONTACT PROJECT CONSTRUCTION REPRESENTATIVE. B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C.ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F. D.ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. E. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. F.ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. G.CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). H.FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK ELECTRICAL DETAILS. I. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. J. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. K. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN. M.SEE ELEVATIONS FOR DISTRIBUTION OF CUP DISPENSERS. N.PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE LOCAL JURISDICTION. KEYED NOTES GENERAL NOTES ADJACENT TENANT (NO WORK) I102 1 F 2306323063 F X5050X5050 F TK0027TK0027 F 2287822878 F TK0027TK0027 F 2271822718 F 2184821848 F 2184821848 F 2306323063 F 2144921449 F 2144921449 F 2144921449 F 2184821848 F 2306323063 F 2145621456 F 2184221842 F 2144921449 F TK0057TK0057 F 2300923009 F 2301123011F2180021800 F 2145321453 F 2271822718 F TK0027TK0027 F X1010X1010 F X1011X1011 F X1010X1010 F X1011X1011 F 2012820128 F 2012820128 [2] [3] [2] [4][2] [2][2]F 2306323063 F 2184821848 F 2144921449 F 2306323063 F 2184821848 F 2144921449 [2][2] [5][4] [4] [3] [3] F TK0063TK0063 E 10416 E 10462 E 11083 E 11083 E 13682 E 22212 E 10222 E 13578 E 15186 E 10947 E 10977 E X0009 E 23182 E 18029 E 23338 [10] [10] Y 2148621486 [2] [2] [4] [4] [13] Y 1214712147 Y 2007320073 Y 2007320073 Y 1214712147 Y 2007320073 Y 1214712147 [2] 1 2 4 5 7 8 9 10 E 10698 E 13834 E 10859 E 10172 E 10099 E 10769 P 22558 E 10862 E 10172 E 10859 E 10099 E 10769 E 10862 P 22558 P 12896 P 12507 P 13082 P 12899 P 12501 P 13076 P 10922 [2] P 10447 P 13264 P 10804 P 18743 P 10153 P 22642 P 10215 P 13588 P 14688I401 4 CAFE ENGINE WORKROOM RESTROOM VEST.RESTROOM 1 RESTROOM 2 F TK0051TK0051 F 2008720087 F 2008720087 PATIO F 1785217852 F 1785217852 DRIVE-THRU 6 [2] E 10976 E 10976 F 2145621456 E 11130 E 11130 E 11130 F 1435014350 [2] F TK0053TK0053 F TK0076TK0076 A 10002 F TK0078TK0078A10022 A 10007 F TK0079TK0079 F TK0077TK0077 A 10076 A 10005 A 18744 E 23423 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I101 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE FF & E PLAN NScale: 1/4" = 1'-0"1 FURNITURE, FIXTURES AND EQUIPMENT PLAN Revision Schedule Rev Date By Description E 10267 E 10267 E 19742E19278 A 10075 E 13330 E 13584 E 10855 E 10091 E 10791 E 10396 E 10858 E 19742 A 10075 E 10267 A 10008 A 10024 A 10028 A 10029 A 10029 A 10029 A 10014 E 16239 E 17255 E 10808 E 22885 E 20032 E 12618 E 12618 A 10075 E 17264 E 23442 E 10267 E 23445 E 23444 E 10267 A 22970 A 23021 [2] [2] [2] [2] [2] [2] [2] [2] 1 2 3 4 4 [29'] P 10153 P 22768 P 22642 P 11003 P 10153 P 22768 P 22642 P 11003 P 10597 P 10152 P 10549 ENGINE E 10267 A 14678 A 14677 A 22725 A 10012 A 10029 A 10014 DRIVE-THRU E 19278 [2] E 21934 I102 2 E 19278 A 22726 L 22216 E 23420E12508 E 12508 E 22627 E 20010 E 21679 E 17564 E 10267 1.DO NOT BLOCK FOOD CASE INTAKE/EXHAUST. 2.SAFE LOCATED AT POS CABINET. SEE ELECTRICAL FOR ADDITIONAL INFORMATION. 3.HAND SINK W/ INTEGRAL SPLASH GUARD. 4.INDICATES EQUIPMENT TO BE INSTALLED AT A FUTURE DATE. A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING. FOR LIST OF APPROVED START UP CONTRACTORS, CONTACT PROJECT CONSTRUCTION REPRESENTATIVE. B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. C.ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F. D.ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. E. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. F.ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. G.CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). H.FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK ELECTRICAL DETAILS. I. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. J. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION REPRESENTATIVE. K. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN. M.SEE ELEVATIONS FOR DISTRIBUTION OF CUP DISPENSERS. N.PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE LOCAL JURISDICTION. KEYED NOTES GENERAL NOTES E 23419 [2]E 23419 E 23421 A 10075 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I102 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE ENLARGED FF & E PLAN Scale: 1/2" = 1'-0"1 ENLARGED FF AND E PLAN N Revision Schedule Rev Date By Description Scale: 3/8" = 1'-0"2 ENLARGED FF&E PLAN - UPPER 1.INSTALL CASEWORK, COUNTERTOPS, SHELVES, CUBBIES, FINISHES, TRIM AND TABLE TOPS THROUGHOUT. 2.ALL COUNTERTOPS SHALL BE INSTALLED AT 2'-10" (860 MM) MAXIMUM A.F.F. MAX. 3.FLOOR DRAIN BELOW. CASEWORK MANUFACTURER TO COORDINATE DESIGN TO INSURE THIS AREA IS READILY ACCESSIBLE FOR CLEANING AND FREE OF COUNTERTOP SUPPORT. A.GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXISTING SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY G.C. B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. C.STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED. D.CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE PROPER INSTALLATION. E. ALL CASEWORK BOX BASES SHALL BE SET AND LEVELED USING 1/4" (6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND TAGGING OF WALL TREATMENTS BY CV AND OTHERS. G. SEE REFLECTED CEILING PLAN FOR ABOVE BAR SOFFIT LOCATIONS. H.REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR. KEYED NOTES GENERAL NOTES INDICATES STAINLESS STEEL (SST) COUNTERTOP LEGEND INDICATES SOLID SURFACE (SS) COUNTERTOP DATUM POINT CAFE RESTROOM VEST.RESTROOM 1 RESTROOM 2 WORKROOM ENGINE 3 3 3 3 1 2 DRIVE-THRU C 23964 C 20383 I103 2 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I103 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE CASEWORK PLAN Scale: 1/4" = 1'-0"1 CASEWORK PLAN Revision Schedule Rev Date By Description N Scale: 1/4" = 1'-0"2 CASEWORK PLAN UPPER A.REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS. B.IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION. C.LEAVE TEN (10) ADDITIONAL RETAIL CEILING TILES TO MATCH RETAIL CEILING PAINT COLOR ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE USE. D.PROVIDE GROMMET AT ACOUSTIC CEILING PENETRATIONS FOR FIXTURES OF SUPPORTS. E.HEATING, VENTILATING AND AIR CONDITIONING SHOWN ON THIS PLAN PROVIDED FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. F.DIFFUSERS AND RETURNS IN ACOUSTICAL CEILING TILE TO BE CENTERED IN TILE AND PAINTED TO MATCH ADJACENT FINISHES (TYP.). G.PAINT ALL EXPOSED HVAC DUCTS, HVAC DIFFUSERS, LIGHT TRIM RINGS, PIPING, CONDUIT AND JUNCTION BOXES THE SAME COLOR AS SPECIFIED ON SURROUNDING CEILING OR SOFFIT UNLESS OTHERWISE NOTED. TYPICAL THROUGHOUT RETAIL AREA OF STORE. H.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. I.DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE. J.DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT OR PER LOCAL CODE REQUIREMENT. KEYED NOTES GENERAL NOTES 1.GWB CEILING. PAINT CEILING DIFFUSERS AS INDICATED. 2.WASHABLE CEILING TILE LOCATED IN BACK OF HOUSE. 3.AIR CURTAIN. REFER TO SPEC FOR EQUIPMENT SIZE. 4.PLATFORM FOR HEATER AND WATER FILTRATION. PROVIDE SOFFIT ABOVE AND LIFT CEILING THIS AREA ONLY TO INSURE ADEQUATE CLEARANCE FOR SERVICING. ALL ENCLOSED SIDES TO RECEIVE FRP. 5.FURNISH AND INSTALL DOOR ACTIVATED AIR CURTAIN PER JURISDICTIONAL REQUIREMENTS. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 6.RECESSED SPEAKER. FINISH COLOR TO BE BLACK OR PAINT TO MATCH ADJACENT FINISH. 7.EXTERIOR AWNINGS. 8.MOUNT DRIVE THRU CAMERA INSTALLED AT 36" TO 72" (915MM TO 1830MM) FROM DRIVE THRU WINDOW WITH CLEAR VIEW OF CUSTOMER AND DRIVE THRU POS. 9.LOCATE SECURITY HEAD UNIT AT MANAGER'S WORKSTATION. LEGEND STRIP LIGHTING PENDANT LIGHT RECESSED CAN LIGHT WALL SCONCE EXIT SECURITY LIGHT SUPPLY AIR RETURN AIR 360° SECURITY CAMERA TROFFER MUSIC SYSTEM RECESSED SPEAKER LINEAR DIFFUSER C CEILING TILE START POINT DATUM ICE CHUTE NUGGET ICE DISPENSER NUGGET ICE CHUTE START/END EXHAUST ADJACENT TENANT (NO WORK) EQ EQ EQ EQ 2' - 8 " 1' - 7 1 / 4 " 2' - 5 " 1' - 1 0 3 / 4 " 1' - 8 1/2"3' - 6"1' - 6"2' - 0"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"1' - 6"2' - 0"3' - 6"3' - 6"1' - 9 1/4" 5' - 6 " 5' - 6 " 4' - 2 " 3' - 1 0 " 3' - 7 " 3' - 1 0 " 3' - 6"2' - 1" 2' - 9 1 / 4 " 3' - 6 " 3' - 6 " 3' - 8 " 2' - 0 " 4' - 0 " 2' - 0 " 1' - 9"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"2' - 0" 5' - 7"1' - 0"3" 2' - 5 1 / 2 " 8" 3" 3' - 6"3' - 6"3' - 6"3' - 6"4' - 10"5' - 0 1/2" 2' - 9 " 1' - 6 " 1' - 6 " 1' - 6 " 2' - 6 " 2' - 6 " 1' - 4 " 3' - 6 " 3' - 6 " 3' - 6 " 3' - 6 " 2' - 8 " 3' - 4"2' - 10" 9' - 6"7' - 0"7' - 0"7' - 0" 3' - 11 1/4"9' - 5 1/2"7' - 0"7' - 0"14' - 0"7' - 0" GYP. CEILING 10' - 0"AFF PAINTED X7045 CAFE GYP. CEILING 9' - 0"AFF PAINTED X7044 RESTROOM 1 GYP. CEILING 9' - 0"AFF PAINTED X7044 RESTROOM VESTIBULE GYP. CEILING 9' - 0"AFF PAINTED X7044 RESTROOM 2 ACT 9' - 0"AFF WHITE WORKROOM GYP. CEILING 10' - 0"AFF PAINTED X7044 DT BUMP BEVELED CIRRUS ACT 10' - 6"AFF MATCHES X7046 CAFE L 20831[3] L 15057 [7] [2] [2] L 21772 L 21772 [2] [2] L 21772[4] L 21772[6] L 21772 [37] L 21772 [24] L 22216 [21'] 2' - 2 1 / 4 " A 22549 A 22549 L X2851 L X2851 1 1 1 1 1 2 4 5 6 6 9 777 7 7 L 22216[31'] EQ EQ 3' - 2"5' - 6"3' - 6" L 15057EQEQ 2' - 5 " 1' - 1 0 1 / 4 " L 21772 L 19049 L 190493 3 3 I503 2 I503 5 I503 6 I503 10 I503 10 I503TYP 8 I503 EQ EQ EQ EQ 5 I503 1 I5031 I503 1 I503 1 I503 1 I503 F 2248722487 [16] 9 I503 14' - 0" 41' - 11 3/4" r 1' - 0 " T Y P . 3' - 1 0 " L 22400[6' 10"] 3' - 2 " 8 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I104 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE REFLECTED CEILING PLAN Scale: 1/4" = 1'-0"1 REFLECTED CEILING PLAN N Revision Schedule Rev Date By Description 1.FLOOR SINK LOCATION. SEE BUILDING FLOOR PENETRATION PLAN ON SHEET A102 AND PLUMBING FOR ADDITIONAL INFORMATION. 2.RECESSED ELECTRICAL. SEE BUILDING FLOOR PENETRATION PLAN ON SHEET A102 AND ELECTRICAL FOR MORE INFORMATION. 3.WALK-OFF MAT AT ENTRY. SEE INERIOR DETAIL SHEETS FOR TRANSITION. 4.MOP SINK WHERE INDICATED. SEE PLUMBING PLANS FOR MORE INFORMATION. A.WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS. B.FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH-GLOSS FINISH. C. STARBUCKS TO SUPPLY FLOORING AND BASE FOR FRONT AND BACK OF HOUSE AS NOTED IN SCHEDULES. GENERAL CONTRACTOR TO INSTALL. GENERAL CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND INSTALL. GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT DAMAGED OR SUBSTANDARD TILES PRIOR TO INSTALLATION. D. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. E.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. KEYED NOTES GENERAL NOTES 4' - 0" 6' - 0 " 4' - 0 " 4' - 0" 1 2 1 1 1 1 1 1 1 11 111 1 2 2 2 2 1 1 1 1 2 2 2 3 3 3 3 3 3 3 32 1 7 1 1 1 2 2 2 1 1 1 2 2 2 2 1 12 I501 12 I501 1 1 1 1 1 1 1 4 3 3 2 2 2 ADJACENT TENANT SPACE 8 I501 8 I501 14 I501 5 I501 13 I501 3 I501 3 I501 2 I501 2 I501 7 I501 TYP 1 I501 8 I501 9 I501 9 I501 8 I501 I501 10 TYP DRIVE-THRUENGINE CAFE WORKROOM RESTROOM VEST. RESTROOM 1 RESTROOM 2 4 I501 4 I501 3 I501 INDICATES NEW METAL BASE: TILE BASE DID: MT0028 WALL BASE LEGEND INDICATES ECO GRIP BASE ECO GRIP BASE DID: 197951 2 INDICATES ECO-GRIP FLOORING DID: 19795 INDICATES EXISTING CONCRETE FLOORING INDICATES WALK-OFF MAT HELIX Z2 - WROUGHT IRON DID 12243 INDICATES SCHLUTER BASE AT TILE WALL3 INDICATES TRANSITION BETWEEN FINISHES SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I105 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE FLOOR FINISH PLAN Scale: 1/4" = 1'-0"1 FLOOR FINISH PLAN N Revision Schedule Rev Date By Description I202 4 I201 2 I202 8 I203 4 I202 3 I203 5 1 4 3 I202 61 9 7 2 13 6I4016 I4017 I401 12 13 14 11 3 5 2 8 9 10 5 2 AAA A A A A A B B B B B B B B B B B BB B B A A A C C C C C CD D D D D D D D D F F F F F F F F I502 1 TYP I502 5 I502 1 I502 3 I502 8 I502 3 I503 7 TYP I503 4 TYP SIM I502 2 SIM B CAFE ENGINE WORKROOM RESTROOM VEST. RESTROOM 2 RESTROOM 1 DRIVE-THRU INDICATES FULL HEIGHT WOOD VENEER PANEL. SEE INTERIOR ELEVATIONS FOR SPECIFIC APPLICATION TYPE. REFER TO DETAILS FOR FURTHER INFORMATION. DID: WD0073 / MAD 200 INDICATES FULL-HEIGHT FRP TO CEILING ABOVE: DID: 11469 D C B A INDICATES FULL-HEIGHT WALL PAINT DID: X7046 SW 7046 AN0NYMOUS INDICATES FULL-HEIGHT WALL TILE TO CEILING ABOVE: DID: 22817 F LEGEND INDICATES WALL TILE TO HEIGHT PER INTERIOR ELEVATIONS DID: 23801 INDICATES FINISH TRANSITION POINT. INDICATES CORNER GUARD PER FF&E PLAN A. WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS. B. INSTALL CORNER GUARDS AS INDICATED. D.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. E. REFER TO INTERIOR ELEVATIONS FOR GRAPHICS LOCATIONS. F.REFER TO CASEWORK FINISH SCHEDULE FOR ADDITIONAL INFORMATION G. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES AS INDICATED IN SCHEDULES. H. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN . ORDERING PAINTS. I. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS OTHERWISE NOTED; -ALL WOOD AND METAL SURFACES SHALL BE PAINTED SEMIGLOSS, OR EQUAL. - ALL ACCENT AND TRIM PAINT TO BE SEMIGLOSS. - ALL WALL AND CEILING PAINTS TO BE EGGSHELL. GENERAL NOTES SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I106 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE WALL FINISH PLAN Scale: 1/4" = 1'-0"1 WALL FINISH PLAN N Revision Schedule Rev Date By Description 1.PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN ON SHEET I103 AND LIGHTING PLAN ON SHEET E102 FOR ADDITIONAL INFORMATION). 2.INSTALL AIR CURTAIN, SEE MECHANICAL FOR MORE INFORMATION. A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B.REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1)WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2)ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a.WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3)PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F.FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G.ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H.REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K.ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L.INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M.GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. KEYED NOTES GENERAL NOTES INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487QWD0073QWD0073 BMT0028BMT0028BMT0028 QWD007310 I503 10 I503 10 I503 8 I501 8 I501 8 I501 5 I502 2 I502SIM, TYP TYP 6 I502 Z 19459 EQ EQ L 19049 QWD0073QWD0073 6' - 0 " 6' - 0 " L X2851 L X2851 2 OPEN TO BEYOND QMT0028 QWD0073 MAD2005 I501 2 I504 3 I504 F 2248722487F2248722487F2248722487F2248722487 QWD0073PTX7046 QMT0028QMT0028 3 I502 8 I501 6 I502 EQ EQ L 19049 2 OPEN TO BEYOND OPEN TO BEYOND 6' - 1 0 " 6' - 6 " 7' - 2 " I504 11 I504 BMT0028 BMT0028 BMT0028 QWD0073 MAD200BWD0073 MAD200 QWD0073 MAD200 10 I503 10 I503 8 I501 8 I501 PT X7046 5 I501 1 6 I503 G 2333123331ASUKA WATANABE CHROMATIC HACIENDA ALSACIA 2 I503 2 I504 3 I504 QWD0073 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I201 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR FINISH ELEVATIONS Scale: 3/8" = 1'-0"1 CAFE 1 Scale: 3/8" = 1'-0"3 CAFE 3 Scale: 3/8" = 1'-0"4 CAFE 4 Scale: 3/8" = 1'-0"2 CAFE 2 Revision Schedule Rev Date By Description 1. ATTACH MENU BOARDS PER INSTALLATION DETAILS. 2.SHELVING FOR CBE STATION AS SHOWN. G.C. TO PROVIDE WALL BLOCKING FOR FASTENERS. 3.CUP DISPENSERS. SEE FF & E PLAN ON SHEET I101 FOR ADDITIONAL INFORMATION. 4.WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE OF COUNTERTOP SUBSTRATE TO BE FRP. 5.TILE START POINT WHERE INDICATED. 6.PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN ON SHEET I103 AND LIGHTING PLAN ON SHEET E102 FOR ADDITIONAL INFORMATION). 7.INSTALL AIR CURTAIN AS REQUIRED PER JURISDICTION. 8.PROVIDE 6" (150MM) MIN. INTEGRAL SPLASHGUARD AT HAND SINK PER JURISDICTIONAL REQUIREMENTS. 9. ICE DISPENSER ACCESS PANEL BEHIND WOOD PANEL. A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B.REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1)WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2)ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a.WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3)PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F.FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G.ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H.REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K.ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L.INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M.GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. KEYED NOTES GENERAL NOTES INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM OPEN TO BEYOND QWD0073 Q 23801I506 2 8' - 6 1 / 2 " 1 8' - 0 1/4" B 19795B19795 B 19795 1 I506 1 I502 5 I502 11 I501 11 I501 7 I501 7 I501 1 I501 7 I503 TYP 3 I503 5 OPEN TO BEYONDOPEN TO BEYOND B 19795 B 19795 11 I501 11 I501 7 I501 Q 11469 2 3' - 1"1' - 1 1/2" 8 B 19795 Q 23801 11 I501 5 1 I503 B 19795Q23801 7 I502 1 I501 Q 23801 5 1 I503 B 19795 Q 23801 11 I501 7 I501 C X0001 5 1 I503 BMT002811 I501 Q 23801 QWD0073Q23801 B 19795 7 I501 10 I503 8 I501 6 I502 2 452 A501 B 19795 9 1 I503 OPEN TO BEYOND B 19795 6 7' - 2 " 6' - 1 0 " 6' - 6 " BMT0028 B 197955 I501 11 I501 35 I501 5' - 0 " QWD0073 BMT0028 10 I503 8 I501 6 I502 3' - 8 1/4" A 22970 OPEN TO BEYOND 6 7' - 2 " 6' - 1 0 " 6' - 6 " 5 I501BMT0028 B 19795 11 I501 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I202 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR FINISH ELEVATIONS Scale: 3/8" = 1'-0"6 ENGINE 6 Scale: 3/8" = 1'-0"5 ENGINE 5 Scale: 3/8" = 1'-0"9 DRIVE-THRU 3 Scale: 3/8" = 1'-0"8 DRIVE-THRU 2 Scale: 3/8" = 1'-0"7 DRIVE-THRU 1 Scale: 3/8" = 1'-0"4 ENGINE 4 Scale: 3/8" = 1'-0"1 ENGINE 1 Scale: 3/8" = 1'-0"3 ENGINE 3 Scale: 3/8" = 1'-0"2 ENGINE 2 Revision Schedule Rev Date By Description INDICATES WALL BLOCKING. BLOCKING TO BE PROVIDED AS REQUIRED TO SUPPORT WALL ATTACHMENTS. EXTEND BLOCKING 4" (100mm) BEYOND EDGE OF ATTACHMENTS. LEGEND WALL TILE START POINT DATUM 1.APPROXIMATE LOCATION OF ICE DIVERTER TO BE CONNECTED TO ICE MACHINE AND CHUTE PER RCP. 2. WALL MOUNT HAND SINK WITH SOAP AND PAPER TOWEL DISPENSER. G.C. TO PROVIDE BLOCKING FOR FASTENERS. 3. ICE MACHINE (SEE PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION). 4.MOP SINK. FULL HEIGHT FRP AT ENCLOSURE (SEE PLUMBING PLANS FOR MORE INFORMATION). 5.WATER HEATER ABOVE (SEE PLUMBING DRAWINGS). 6.MANAGERS DESK. SEE MANAGER'S DESK/EQUIPMENT RACK ELECTRICAL DETAIL FOR ADDITIONAL INFORMATION. 7.ELECTRICAL PANELS (SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION). 8.WATER FILTRATION EQUIPMENT (SEE PLUMBING DRAWINGS). A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON SHEET I601. B.REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION. C.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE INDICATED. D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1)WOODS AND METAL SURFACES SHALL BE SEMI-GLOSS OR EQUAL. 2)ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL. a.WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL. 3)PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR EQUAL. E.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN ORDERING PAINTS. F.FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH. G.ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H.REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION. I.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. J.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. K.ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F. L.INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR TILE. M.GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. N.GENERAL CONTRACTOR TO COORDINATE MECHANICAL, ELECTRICAL, FIRE ALARM, SECURTY & PLUMBING TRADES TO AVOID EQUIPMENT / MATERIAL IMPACTING PROPOSED ART OR FIXTURE INSTALLATIONS. KEYED NOTES GENERAL NOTES OPEN TO BEYOND Q 19795 Q 11469 2 I501 1' - 6 3/4"Q 11469 Q 19795 2 I501 14 I501 Q 19795 TYP Q 11469 5 8 43 7 A501 6' - 1 0 3 / 4 " 7 Q 11469 Q 19795 2 I501 5 4 OPEN TO BEYOND Q 11469Q11469Q11469 Q 19795Q19795Q19795Q19795 2' - 1 0 " 3' - 8 " 2 I501 TYP 9" 8 1/2"6 3/4" 5' - 0 " 3' - 8 3/4" 5' - 6 " Q 11469 6 2 7' - 4 3 / 4 " 2' - 5 3/4" 2 I501 Q 11469 Q 19795 2 I501 Q 11469 Q 19795 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I203 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR FINISH ELEVATIONS Scale: 3/8" = 1'-0"1 BOH 1 Scale: 3/8" = 1'-0"2 BOH 2 Scale: 3/8" = 1'-0"3 BOH 3 Scale: 3/8" = 1'-0"4 BOH 4 Scale: 3/8" = 1'-0"6 BOH 6 Scale: 3/8" = 1'-0"5 BOH 5 Revision Schedule Rev Date By Description A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. B.ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED DATUM POINT. C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS OTHERWISE NOTED. D.DIAPER CHANGING STATION IS TO BE INSTALLED PER MANUFACTURER ’S INSTRUCTIONS. UNIT IS TO BE FASTENED TO STRUCTURE AT ALL SIX CHASSIS ATTACHMENT POINTS. E.LOCATE DIAPER CHANGING STATION AS SHOWN TO ALLOW NECESSARY CLEARANCE FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. F.ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND CLEARANCES SHALL COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE LOCAL JURISDICTION. 1.67" (1700MM) ACCESSIBLE TURNING RADIUS. 2.30" (760MM) X 52" (1320MM) CLEAR FLOOR SPACE. 3.WATER CLOSET CLEAR FLOOR SPACE. 4.SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ALL SENSORS AND CONTROLS (TYPICAL). 5.TILE START POINT . FULL TILE ABOVE BASE COVE. CENTER FULL TILE ON WALL (HORIZONTALLY). 6.WALL MOUNTED LAVATORY INSTALLED WITH SUPPORT CARRIER AND INSULATED BOOT AT EXPOSED PIPES. 7.CENTER MIRROR OVER LAVATORY. MOUNT AT 40" (1015MM) MAX. TO BOTTOM EDGE OF REFLECTIVE SURFACE. 8.COAT HOOK. MOUNT AT CENTERLINE OF DOOR. 9.CENTER SCONCE LIGHTING OVER MIRROR (SEE ELECTRICAL). 10.IN-WALL WOOD BLOCKING. VERIFY BLOCKING LOCATION, EXTENTS AND BLOCKING WITH MANUFACTURER'S REQUIREMENTS. KEYED NOTES GENERAL NOTES 2' - 0"1' - 0" 3' - 0" 2' - 9 " 1' - 5 3 / 4 " 1' - 6" 2' - 9 " 1' - 7 " 3' - 5 " 1' - 6 " 3' - 3" 6"4' - 0" 3' - 3 1/2"5 1/4" 1' - 6 1/4" 2' - 3 " 2' - 9 " 1' - 6 " 4" .. 3' - 3 " 2' - 9 " DIAPER CHANGING STATION SIDE AND FRONT ELEVATIONS ELECTRIC HAND DRYER FRONT ELEVATION 4' - 0 " HAND SINK FRONT ELEVATION COAT HOOK ELEVATION HAND SINK SIDE ELEVATION TOILET FRONT ELEVATION TOILET SIDE ELEVATION INSTALL HEIGHT PER MANUFACTURER'S INSTRUCTION 3' - 6 " I4016 I4017 I401 12 13 14 113 5 2 8 9 10 RESTROOM VEST.RESTROOM 1 RESTROOM 2 11 1 2 3 3 E 10172 E 10859 E 10769 E 10099 E 10976 E 10862 F 1435014350 F 1435014350 F 1075610756 F 1075610756 E 10862 E 10859 E 10976 E 10769 E 10099 E 10172 7 7 8 8 OPEN TO BEYOND BMT0028 PT X7046 9" BMT0028 PT X7046 PT X7046 PT X7046 4 I501 BMT0028 PT X7046 PT X7046 PT X7046 4 I501 Q 22823 BMT0028 6' - 1 0 " EQ EQ 7 9 6 L 20750 [2] 5 CENTER START TILE WITH LAVATORY. [2] 13 I501 F 1435014350 Q 22823 5 TYP3 I501 10 Q 22823 5 PT X7046 PT X7046 Q 22823 5 4 8 Q 22823 5 10 Q 22823 5 3 I501 TYP 10 Q 22823 PT X7046 PT X7046 5 4 8 Q 22823 5 Q 22823 10 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I401 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE RESTROOM PLAN & ELEVATIONS Scale: 3/8" = 1'-0"1 MOUNTING HEIGHTS FOR RESTROOM ACCESSORIES Scale: 1/2" = 1'-0"4 ENLARGED RESTROOM PLAN Scale: 3/8" = 1'-0"5 VESTIBULE - NORTH Scale: 3/8" = 1'-0"3 VESTIBULE - EAST Scale: 3/8" = 1'-0"2 VESTIBULE - SOUTH Scale: 3/8" = 1'-0"6 VESTIBULE - WEST Scale: 3/8" = 1'-0"11 RESTROOM 1 - SOUTH Scale: 3/8" = 1'-0"13 RESTROOM 1 - NORTH Scale: 3/8" = 1'-0"14 RESTROOM 1 - WEST Scale: 3/8" = 1'-0"12 RESTROOM 1 - EAST Scale: 3/8" = 1'-0"7 RESTROOM 2 - WEST Scale: 3/8" = 1'-0"10 RESTROOM 2 - NORTH Scale: 3/8" = 1'-0"9 RESTROOM 2 - EAST Scale: 3/8" = 1'-0"8 RESTROOM 2 - SOUTH N Revision Schedule Rev Date By Description WALL TILE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATIONS WALL TYPE PER LEGEND FLOOR FINISH PER SCHEDULE SCHLUTER COVE-SHAPED PROFILE FOR FLOOR/WALL TRANSITIONS ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE ECO-GRIP SEALANT ECO-GRIP FLOORING 1/4" (6MM) ROUTED COVE STAINLESS STAPLE OR POWDER COATED FASTENER WALL AND SHEATHING PER PLAN WALL TILE PER PLAN THINSET CONCRETE SLAB ECO-GRIP FLOORING ECO-GRIP SEALANT ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED FASTENER CABINET FINISH FACE INSTALL CASEWORK BASE PRIOR TO ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE 1/4" (6MM) ROUTED COVE CONCRETE SLAB 6" ( 1 5 0 M M ) M I N . WALL AND SHEATHING PER PLAN ECO-GRIP EPOXY ADHESIVE ECO-GRIP SEALANT ECO-GRIP FLOORING CABINET LEG 1/4" (6MM) ROUTED COVE ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED STEEL FASTENER CABINET ABOVE CONCRETE SLAB 6" ( 1 5 0 M M ) M I N . ECO-GRIP FLOORING ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED STEEL FASTENER BAR DIEWALL INSTALL CASEWORK DIEWALL PRIOR TO ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE 1/4" (6MM) ROUTED COVE BAR FINISH PANEL CONCRETE SLAB 6" ( 1 5 0 M M ) M I N . PLASTIC SHIM REQUIRED - 1/4" MIN.2" ECO-GRIP SEALANT FLOORING PER SCHEDULE 6" (150MM) METAL BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATION. CLEAR SILICONE SEALANT ALUMINUM DOWEL SECURED INTO SUB FLOOR & DIEWALL 6" CAFE BAR NOTE: ALL COMPONENTS FURNISHED BY OTHERS AND INSTALLED BY G.C. UNLESS NOTED OTHERWISE. ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE ECO-GRIP SEALANT ECO-GRIP FLOORING 1/4" (6MM) ROUTED COVE STAINLESS STAPLE OR POWDER COATED FASTENER FRP WALL COVERINGWALL AND SHEATHING PER PLAN CONCRETE SLAB ECO-GRIP EPOXY ADHESIVE ECO-GRIP FLOORING 1/4" (6MM) ECO-GRIP SPEEDFLEX MOP SINK CONCRETE SLAB . ECO-GRIP FLOORINGECO-GRIP EPOXY ADHESIVE 1/4" (6MM) ROUTED COVE INSTALL CASEWORK BASE PRIOR TO ECO-GRIP FLOORING 6" (150MM) +/- TYP. A.F.F. CABINET TOE-KICK OVERHANG CONCRETE SLAB ECO-GRIP BASE CAP. COLOR TO MATCH ECO-GRIP FLOORING STAINLESS STAPLE OR POWDER COATED FASTENER ECO-GRIP SEALANT SEALANT TO MATCH ADJACENT WALL FINISH 6" (150MM) METAL BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATION. CLEAR SILICONE SEALANT FINISH FLOOR PER SCHEDULE 1/ 4 " ALUMINUM TRIM AT BOTTOM OF PANELS WOOD PANEL, REFER TO ELEVATION FOR PANEL TYPES PANEL MOUNTED WITH ALUMINUM Z-CLIPS WALL TYPE PER PLAN SEALANT TO MATCH ADJACENT WALL FINISH 6" (150MM) METAL BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATION. CLEAR SILICONE SEALANT FINISH FLOOR PER SCHEDULE CONCRETE SLAB WALL TYPE PER LEGEND SEALANT TO MATCH ADJACENT WALL FINISH 6" (150MM) METAL BASE PER SCHEDULE. ADHERE TO WALL PER MFR'S RECOMMENDATION. CLEAR SILICONE SEALANT FINISH FLOOR PER SCHEDULE WALL TYPE PER PLAN 1/ 4 " WALL TILE PER SCHEDULE WATERPROOF MEMBRANE ON WOOD SUBFLOOR ONLY STOREFRONT DOOR WITH THRESHOLD WALK-OFF MAT PER SCHEDULE METAL REDUCER STRIP AT ALL EDGES. ADHERE AND MECHANICALLY FASTEN TO SUBSTRATE PER MFR'S RECOMENDATION PER WALK-OFF MAT MFR. . SEALED CONCRETE FLOOR CONCRETE SLAB FLOOR SINK GRATE FLOOR SINK FLANGE, SET ABOVE ECO GRIP 1/ 4 " ( 6 M M ) T Y P . ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE ECO-GRIP COLOR MATCHED SPEEDFLEX ECO-GRIP FLOORING ECO-GRIP EPOXY ADHESIVE 16 GA. 2 1/4" (57MM) WIDE STAINLESS STEEL TRANSITION STRIP SEALED CONCRETE FLOOR STAINLESS FASTENER LEAD ANCHOR ROUTE OUT FLOORING TO DEPTH OF TRANSITION STRIP SEALANT . 1/4" (6MM) TYP. SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I501 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR DETAILS - FLOOR Scale: 6" = 1'-0"3 SCHLUTER COVED BASE Scale: 6" = 1'-0"1 ECO-GRIP - BASE AT TILED WALL Scale: 6" = 1'-0"6 ECO-GRIP BASE AT CABINET SIDE Scale: 6" = 1'-0"7 ECO-GRIP BASE AT CABINET WITH LEGS Scale: 6" = 1'-0"5 FINISH PANEL - 6" BASE Scale: 6" = 1'-0"2 ECO-GRIP BASE CAP WITH FRP Scale: 12" = 1'-0"14 ECO-GRIP AT MOP SINK Scale: 6" = 1'-0"11 ECO-GRIP BASE AT CABINET FRONT Scale: 6" = 1'-0"12 STOREFRONT MOUNT WALK OFF MATT Scale: 12" = 1'-0"10 ECO-GRIP TO FLOOR SINK TRANSITION Scale: 12" = 1'-0"9 ECO-GRIP TO CONCRETE TRANSITION Revision Schedule Rev Date By Description Scale: 6" = 1'-0"8 METAL BASE AT WOOD PANEL Scale: 6" = 1'-0"4 METAL BASE AT WALL Scale: 6" = 1'-0"13 METAL BASE AT TILE CLEAR SILICONE, TYP HEIGHT PER ELEVATION EXISTING WALL WALL TILE PER SCHEDULE WINDOW SILL PER SCHEDULE WOOD PANEL, REFER TO ELEVATION FOR PANEL TYPES WALL TYPE PER LEGEND PANEL MOUNTED WITH ALUMINUM Z-CLIPS PLYWOOD SUBSTRATE, PAINT MATT BLACK WHERE VISIBLE 1/ 4 " WALL TYPE PER FLOOR PLAN WOOD PANEL (WD0073) PANEL MOUNTED WITH ALUMINUM Z-CLIPS PLYWOOD SUBSTRATE, PAINT MATT BLACK WHERE VISIBLE SCHLUTER-JOLLY EMBEDDED IN GROUT WALL TILE PER SCHEDULE CEMENTITOUS BACKER BOARD 1/4" WALL TYPE PER FLOOR PLAN WOOD PANEL (WD0073) METAL INLET AT MITER CORNER PANEL MOUNTED WITH ALUMINUM Z-CLIPS PLYWOOD SUBSTRATE, PAINT MATT BLACK WHERE VISIBLE EXISTING STOREFRONT WINDOW SYSTEM I502 5 SIMBACKER ROD AND CAULKING BETWEEN WOOD AND WINDOW MULLION EXISTING WALL CONSTRUCTION WOOD PANEL (WD0073) PANEL MOUNTED WITH ALUMINUM Z-CLIPS PLYWOOD SUBSTRATE, PAINT MATT BLACK WHERE VISIBLE METAL MT0028 END CAP. ADHERE TO WALL AND MECHANICALLY FASTEN AS REQUIRED. METAL ANGLE TRIM WOOD PANEL TILE WALL TYPE AND SHEATHING PER BUILDING FLOOR PLAN SCHLUTER-JOLLY EMBEDDED IN GROUT WALL TILE PER SCHEDULE CEMENTITOUS BACKER BOARD WALL TYPE PER LEGEND WOOD PANEL (WD0073) METAL INLET AT MITER CORNER PANEL MOUNTED WITH ALUMINUM Z-CLIPS PLYWOOD SUBSTRATE, PAINT MATT BLACK WHERE VISIBLE WALL TYPE PER FLOOR PLAN WOOD PANEL (WD0073) PANEL MOUNTED WITH ALUMINUM Z- CLIPS SPACED PER MFR RECOMMENDATION PLYWOOD SHEATHING FRP AS SCHEDULED MARLITE F570 EDGE TO MATCH FRP SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I502 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR DETAILS - WALL Scale: 6" = 1'-0"7 TILE WALL TO WINDOW SILL TRANSITION Scale: 6" = 1'-0"6 WOOD PANEL REVEAL Scale: 6" = 1'-0"3 WOOD PANEL INSIDE CORNER Scale: 6" = 1'-0"5 WOOD PANEL OUTSIDE CORNER Scale: 6" = 1'-0"1 WOOD PANEL @ STOREFRONT WINDOW Scale: 3" = 1'-0"4 WOOD SLAT CORNER DETAIL Scale: 6" = 1'-0"2 TILE TO WOOD TRANSITION Revision Schedule Rev Date By Description Scale: 6" = 1'-0"8 WOOD PANEL TO FRP OUTSIDE CORNER CLEAR SEALANT METAL STARTER STRIP EMBEDDED IN GROUT CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE WALL TYPE PER LEGEND MA X 1/ 4 " GYP CEILING PER RCP LED STRIP PER RCP GYP 4" WALL TYPE PER FLOOR PLAN 5/8" GYP PAINTED PER RCP FUR OUT TO ACHIEVE DIMENSIONED DEPTH SUBSTRATE TO BE PAINTED SW7020 BLACK FOX PANEL MOUNTED WITH ALUMINUM Z-CLIPS WOOD PANEL, REFER TO ELEVATION FOR PANEL TYPES 3/ 4 " 7'-6" AFF GYP WALL GYP CEILING PER RCP GYP CEILING PER RCP WALL TYPE PER FLOOR PLAN CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE WALL TILE PER SCHEDULE WALL TYPE PER FLOOR PLAN METAL SCHLUTER JOLLY EMBEDDED IN GROUT WALL TILE PER SCHEDULE CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE LED STRIP PER RCP PAINTED GYP PER ELEVATIONS/RCP 4" WALL TYPES PER FLOOR/FRAMING PLANS PER RCP ARTWORK INSTALLED AS WALLCOVERING PER SCHEDULE. APPLY TO WALL PER MFR'S RECOMMENDATION ALUMINUM "J" MOULDING. COLOR TO MATCH WALLCOVERING 4" 7'-6" AFF PER RCP PER RCP GYP. BOARD, PAINT PER RCP GYP. BOARD, PAINT PER RCP 2' X 4' ACT CEILING PER RCP ARMSTRONG CIRRUS 6X48 MATCH PAINT SW7047 WOOD TRIM, NAILED IN PLACE, HOLES FILLED AND PUTTIED TO CONCEAL NAILS. GYP CEILING PAINTED PER RCP 6" HEIGHT PER RCP HEIGHT PER RCP PLYWOOD BLOCKING TO SECURE TRIM ALIGN 2" CLEAR SEALANT METAL STARTER STRIP EMBEDDED IN GROUT CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE WALL TYPE PER LEGEND MA X 1/ 4 " CEILING PER RCP CLEAR SEALANT METAL STARTER STRIP EMBEDDED IN GROUT CEMENTITOUS BACKER BOARD WALL TILE PER SCHEDULE WALL TYPE PER LEGEND MA X 1/ 4 " GYP CEILING PER RCP LED STRIP PER RCP GYP 4" GYP CEILING PER RCP 7'-6" AFF GYP SOFFIT SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I503 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR DETAILS - WALL/CEILING Scale: 3" = 1'-0"3 LIGHT COVE AT BACKBAR TILE Scale: 6" = 1'-0"10 WOOD PANEL TOP AT CEILING Scale: 1 1/2" = 1'-0"6 HEADER @ RESTROOM VESTIBULE Scale: 6" = 1'-0"4 TILE TO TILE INSIDE CORNER Scale: 6" = 1'-0"7 TILE TO TILE OUTSIDE CORNER Revision Schedule Rev Date By Description Scale: 3" = 1'-0"2 4" LIGHT COVE @ WALLCOVERING Scale: 1 1/2" = 1'-0"5 SOFFIT TRANSITION Scale: 3" = 1'-0"8 RECESSED ACT AT CAFE Scale: 6" = 1'-0"1 TILE AT CEILING Scale: 3" = 1'-0"9 BACKBAR TILE HEADER FACE OF WALL ELEVATION VIEW - BACKING PLAN VIEW - ELECTRICAL COMPONENTS PLAN VIEW (3 9 0 M M ) 1' - 3 1 / 4 " (1 8 0 M M ) 7" (T Y P . ) 3" ( 7 5 M M ) CLEATS FASTENED TO PLYWOOD BACKER (205MM) 8"BANQUETTE WIDTH VARIES (205MM) 8" (8 4 5 M M ) 2' - 9 1 / 4 " TOP OF FINISHED FLOOR 3/4" PLYWOOD BACKER TO BE INSTALLED BEHIND WALL FINISH BY G.C. FASTENED TO STRUCTURE BEYOND (1 3 0 M M ) 5" EQ EQ BANQUETTE LENGTH VARIES DUPLEX OUTLET FOR BANQUETTE POWER OUTLET. VERIFY OUTLET QUANTITY PER FF&E SCHEDULE. EDGE OF BANQUETTE CONVENIENCE OUTLET BUILT INTO BANQUETTE FRAME FACE OF WALL EDGE OF BASE BELOW SHROUD/SPLASH FINISH TO MATCH COUNTERTOP, TYP. 1 1/2" 6" COVE DETAIL ON THIS SIDE ONLY 34" MAX. A.F.F. CORIAN COUNTERTOP NOTE: ALL COMPONENTS FURNISHED BY OTHERS AND INSTALLED BY G.C. UNLESS NOTED OTHERWISE. 34" MAX. AFF METAL ANGLE, TYP. COUNTERTOP SUBSTRATE ALUM. Z-CLIPS, TYP. FINISH PANEL DIEWALL COUNTERTOP OPTIONAL LED STRIP LIGHTING BY OTHERS VARIES MI N . 1/ 2 " 4" (TYP.) NOTE: ALL COMPONENTS FURNISHED BY OTHERS AND INSTALLED BY G.C. UNLESS NOTED OTHERWISE. 4 " SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I504 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR DETAILS - WALL/CEILINGScale: 3/4" = 1'-0"1 BANQUETTE - WALL FLOWER- ELECTRICAL Scale: 6" = 1'-0"2 ESP SHROUD - CORIAN Scale: 6" = 1'-0"3 FINISH PANEL - BUILT-UP COUNTERTOP OVERHANG Revision Schedule Rev Date By Description . 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. HANGAR WIRE AT EACH PERIMETER MAIN TEE AND PERIMETER CROSS TEE GRID SUSPENSION SYSTEM FASTEN TO STRUCTURE PER CISCA 3-4 (FIGURES 2, 3, 4, AND 5) AS MODIFIED BY ASCE 7-05. SECTION 13.5.6.2.2 12 GAGE MINIMUM HANGAR WIRES AT 4'-0" OC EACH DIRECTION - NO MORE THAN 1:6 OUT-OF-PLUMB, TYPICAL WIRE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM AT EACH END OF HANGAR WIRE WITHIN A 3" MAXIMUM LENGTH WHERE HANGAR WIRES ARE MORE THAN 1:6 OUT- OF-PLUMB, PROVIDE COUNTER-SLOPING WIRES METAL-FRAMED TRAPEZE AS NECESSARY TO AVOID OBSTRUCTIONS MAINTAIN HANGAR WIRE SPACING AND CAPACITY BELOW OBSTRUCTION 5/8" GYPSUM BOARD LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (1) 12 GAGE TAUT OR SLACK WIRE LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS, AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 20 POUNDS AND LESS THAN 56 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (2) 12 GAGE TAUT OR SLACK WIRES ATTACHED AT DIAGONAL CORNERS.LIGHT FIXTURES AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 56 POUNDS AND ALL PENDANT LIGHT FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING APPROVED HANGARS LIGHT FIXTURES, AIR TERMINALS, AND SERVICES SHALL BE POSITIVELY ATTACHED TO THE CEILING SYSTEM 2 X 2 SHEET METAL ANGLE CLCL 8" MAX EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SHALL BE INDEPENDENTLY SUPPORTED AND BRACED FROM STRUCTURE GYPSUM BOARD CONSTRUCTION SHALL COMPLY WITH ADDITIONAL PROVISIONS OF SBC SECTION 2508. METAL SUSPENSION SYSTEM SHALL CONFORM WITH ASCE 7, SECTION 13.5.6.2.1, ASTM C635, ASTM C636, ASTM C754, AND CISCA 3-4. NOT REQUIRED IN SEISMIC DESIGN CATAGORY C FOR CEILINGS LESS THAN 144 SF A PERIMETER SUPPORT B GENERAL SUPPORT C LIGHT FIXTURE AND MECHANICAL SERVICE SUPPORT FOUR 12 GAGE MINIMUM WIRES SPLAYED 90 DEGREES (IN PLAN) FROM EACH OTHER AND SECURED TO MAIN RUNNER WITHIN 2" OF INTERSECTION. EACH END OF EACH WIRE TO BE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM WITHIN A 3" MAX LENGTH. .FOR SPANS UP TO 6'-0", USE A SINGLE 20 GAGE 1 5/8" COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8 SCREWS AND TO STRUCTURE WITH (2) HILTI X-DNI .145 DIA X 3/4" FOR SPANS UP TO 9'-0", USE DOUBLE COMPRESSION STRUT 4 5 ° M A X 45° M A X 45 ° M A X 45 ° M A X LOCATE BRACING AT 12'-0" OC EACH DIRECTION AND WITHIN 6'-0" OF PERIMETER WALLS, PARTITIONS, OR EXPANSION JOINTS E LATERAL BRACING REQUIRED IF ANY OF THE FOLLOWING EXISTS: -GYPSUM BOARD CEILING THAT EXTENDS WALL-TO-WALL EXCEEDS 1000 SF -GYPSUM BOARD CEILING THAT DOES NOT EXTEND WALL-TO-WALL EXCEEDS 144 SF CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE LATERAL BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1 SEISMIC DESIGN CATEGORY C: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 3/8" IN ALL HORIZONTAL DIRECTIONS SEISMIC DESIGN CATEGORY D, E, ANF F: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 1" IN ALL HORIZONTAL DIRECTIONS. F EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF D SPRINKLER HEAD CLEARANCE NOT REQUIRED IN SEISMIC DESIGN CATEGORY C PROVIDE CEILING EXPANSION JOINTS AS NECESSARY, DIVIDING CEILING INTO AREAS NO GREATER THAN 2500 SF CL8" MAX EACH SIDE 2" . 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. HANGAR WIRE AT EACH PERIMETER MAIN TEE AND PERIMETER CROSS TEE STABILIZER BAR TO MAINTAIN PERIMETER TEE SPACING MAIN TEE OR CROSS TEE (SUSPENSION SYSTEM) HEAVY DUTY FASTEN TO STRUCTURE PER CISCA 3-4 (FIGURES 2, 3, 4, AND 5) AS MODIFIED BY ASCE 7-05. SECTION 13.5.6.2.2 12 GAGE MINIMUM HANGAR WIRES AT 4'-0" OC EACH DIRECTION - NO MORE THAN 1:6 OUT-OF-PLUMB, TYPICAL WIRE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM AT EACH END OF HANGAR WIRE WITHIN A 3" MAXIMUM LENGTH WHERE HANGAR WIRES ARE MORE THAN 1:6 OUT- OF-PLUMB, PROVIDE COUNTER-SLOPING WIRES METAL-FRAMED TRAPEZE AS NECESSARY TO AVOID OBSTRUCTIONS MAINTAIN HANGAR WIRE SPACING AND CAPACITY BELOW OBSTRUCTION ACOUSTICAL CEILING PANELS LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (1) 12 GAGE TAUT OR SLACK WIRE LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS, AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 20 POUNDS AND LESS THAN 56 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (2) 12 GAGE TAUT OR SLACK WIRES ATTACHED AT DIAGONAL CORNERS LIGHT FIXTURES AND AIR TERMINALS / SERVICES WEIGHING MORE THAN 56 POUNDS AND ALL PENDANT LIGHT FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING APPROVED HANGARS LIGHT FIXTURES, AIR TERMINALS, AND SERVICES SHALL BE POSITIVELY ATTACHED TO THE CEILING SYSTEM 2 X 2 CLOSURE ANGLE, MINIMUM. SEE NOTE AT TOP CLCL 8" MAX EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SHALL BE INDEPENDENTLY SUPPORTED AND BRACED FROM STRUCTURE COMPLY WITH ADDITIONAL PROVISIONS OF ASTM C635, ASTM C636, CISCA 3-4, AND ASCE 7-05, SECTION 13.5.6. NOT REQUIRED IN SEISMIC DESIGN CATAGORY C FOR CEILINGS LESS THAN 144 SF A PERIMETER SUPPORT B GENERAL SUPPORT C LIGHT FIXTURE AND MECHANICAL SERVICE SUPPORT FOUR 12 GAGE MINIMUM WIRES SPLAYED 90 DEGREES (IN PLAN) FROM EACH OTHER AND SECURED TO MAIN RUNNER WITHIN 2" OF INTERSECTION. EACH END OF EACH WIRE TO BE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM WITHIN A 3" MAX LENGTH. FOR SPANS UP TO 6'-0", USE A SINGLE 20 GAGE 1 5/8" COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8 SCREWS AND TO STRUCTURE WITH (2) HILTI X-DNI .145 DIA X 3/4". FOR SPANS UP TO 9'-0", USE DOUBLE COMPRESSION STRUT. PROVIDE CEILING EXPANSION JOINTS AS NECESSARY, DIVIDING CEILING INTO AREAS NO GREATER THAN 2500 SF. SEISMIC DESIGN CATEGORY C: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 3/8" IN ALL HORIZONTAL DIRECTIONS. SEISMIC DESIGN CATEGORY D, E, ANF F: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 1" IN ALL HORIZONTAL DIRECTIONS. 4 5 ° M A X 45° M A X 45 ° M A X 45 ° M A X LOCATE BRACING AT 12'-0" OC EACH DIRECTION AND WITHIN 6'-0" OF PERIMETER WALLS, PARTITIONS, OR EXPANSION JOINTS CL 8" MAX MAIN T E E E LATERAL BRACING FOR CEILINGS EXCEEDING 144 SF F EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF D SPRINKLER HEAD CLEARANCE CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE LATERAL BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1 NOT REQUIRED IN SEISMIC DESIGN CATEGORY C SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I505 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR DETAILS - SUSPENDED CEILINGScale: 1 1/2" = 1'-0"1 SUSPENDED GYP BD CEILING - IBC SEISMIC CATEGORY C, D, E, F Scale: 1 1/2" = 1'-0"2 SUSPENDED ACOUSTICAL CEILING SYSTEM - IBC DESIGN CATEGORY C, D, E, F Revision Schedule Rev Date By Description BULKHEAD/SOFFIT FRAMING WOOD CLADDING DIGITAL MENU DISPLAY SCREENS, PER SCHEDULE DISPLAY SCREEN BRACKET, PER SCHEDULE. BRACKET AFFIXED TO WALL PER MANUFACTURES RECOMMENDATIONS AND REQUIREMENTS DIRRECTLY OVER THE TOP OF WOOD SLAT PANELS. BULKHEAD/SOFFIT FRAMING. PROVIDE IN-WALL BLOCKING FOR DISPLAY SCREEN BRACKETS PER MANUFACTURES RECOMMENDATIONS AND REQUIREMENTS. MI N . B L O C K I N G ( V I F ) 3' - 1 1 / 4 " ( 9 2 0 M M ) (2 3 0 M M ) 6" CENTER OF MENU BOARDS AT 7' - 4" (2235MM) A.F.F. MIN., 8' - 6" (2590MM) A.F.F. MAX. SEE INTERIOR ELEVATIONS FOR ACTUAL DIMENSION 3/4" PLYWOOD BACKING BEHIND WALL FINISH, SECURED TO STRUCTURE METAL RECESSED CABLE MANAGEMENT AND POWER STORAGE BOX. MINIMUM (1) RECEPTACLES AND (1) DATA PORT PER SCREEN. MINIMUM (4) OUTLETS AND (4) DATA PORTS PER STORE. CENTER OF MENU ASSEMBLY 3' - 8 1/4"3' - 8 1/4" 4"4"4"4"6"6"4"4" 2' - 9"2' - 9" MIN. OFFSET (TYP.) 6"WALL MOUNTED MENU BOARD BRACKET DIGITAL SCREEN EQ EQ EQ.11' - 0 1/2" (3364.2MM 3 SCREENS)EQ. 12' - 0 1/2" (3670.3 MM MIN. BLOCKING (VIF)) MI N . O F F S E T ( T Y P . ) 6" MAX. LENGTH DATA (5'-6") MAX. LENGTH POWER (5'-6") r 5 ' - 6 " r 5 ' - 6 " 1 I506 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I506 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR DETAILS - MENU BOARDS Scale: 1 1/2" = 1'-0"1 DIGITAL MENUS - SECTION Scale: 3/4" = 1'-0"2 DIGITAL MENU BOARDS - STANDARD MOUNT Revision Schedule Rev Date By Description SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I601 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE INTERIOR FINISHES & CASEWORK SCHEDULES WALL TREATMENT (AREA) SCHEDULE - "Q" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS WD0073 638 SF WOOD - WHITE OAK SB GC WD0073 MAD200 157 SF WOOD - WHITE OAK - ROUNDED SLAT - VERTICAL SB GC TILE 22823 537 SF TILE - MOSA - LIGHT BEIGE SMOOTH - 6X24IN 150X600MM SB GC GROUT: MAPEI - 11 SAHARA BEIGE, OR EQUAL 23801 663 SF TILE - I COCCI - GENERE - 6X24IN 150X600MM SB GC GROUT: MAPEI - 93 WARM GRAY WALL COVERING 11469 1770 SF FRP - WHITE GC GC PAINT SCHEDULE DESIGN ID DESCRIPTION LRV FURN. BY INST. BY COMMENTS X2851 SW2851 SAGE GREEN LIGHT, OR EQUIVALENT 16 GC GC X7044 SW7044 AMAZING GRAY, OR EQUAVALENT 47 GC GC X7045 SW7045 INTELLECTUAL GRAY, OR EQUIVALENT 36 GC GC SW USE PRIMER CP-1; NCS - S 3005-Y20R; AKZO NOBEL - 40YY 44/095 X7047 SW7047 PORPOISE, OR EQUIVALENT 13 GC GC FLOOR TREATMENT SCHEDULE - "T" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS CONCRETE X1112 1046 SF CONCRETE - SEALED & POLISHED GC GC PLASTIC 19795 992 SF POLYVINYL FLOOR TILE - ECO-GRIP - PEWTER GC GC GC TO PROCURE FROM ALLIED INDUSTRIES WALL BASE SCHEDULE - "B" DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS METAL BASE MT0028 121' - 5"METAL BASE, 6 IN, POWDER COAT, MATTE BLACK SB GC AT ENGINE FRONT - PROVIDED BY CASEWORK VENDOR VINYL BASE 19795 312' - 11"POLYVINYL BASE - ECO-GRIP - PEWTER GC GC LOCALLY SOURCED CEILING TREATMENT SCHEDULE - "U" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS PLASTIC 11302 328 SF ACT VINYL - 2x4'GC GC MFR: ARMSTRONG MODEL: 972 LUMAWASH CASEWORK SCHEDULE - "C" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS CABINET 17573 1 CABINET - BACKBAR COUNTER SUPPORT PANEL - 3IN 75MM SB GC 17574 1 CABINET - BACKBAR SINK OR ICE - 15IN 380MM SB GC 17740 2 CABINET - BACKBAR - 30IN 760MM SB GC 17741 5 CABINET - BACKBAR 15IN 380MM SB GC 17743 1 CABINET - DT POS - 30IN 760MM SB GC 17744 1 CABINET - FRONTBAR POS BRIDGE - 22IN 560MM SB GC 17745 1 CABINET - BACKBAR DRAWER - 15IN 380MM SB GC 17747 8 CABINET - BACKBAR TRASH - 15IN 380MM SB GC 17896 1 CABINET - BACKBAR CUBBY - 15IN 380MM SB GC 19281 2 CABINET - ESPRESSO ICE BIN STAINLESS - 20IN 510MM SB GC 21189 1 CABINET - FRONTBAR - 15IN 380MM SB GC 21190 1 CABINET - FRONTBAR TRASH - 15IN 380MM SB GC 21191 1 CABINET - FRONTBAR DRAWER - 15IN 380MM SB GC 21192 2 CABINET - FRONTBAR POS - 30IN 760MM SB GC 21193 1 CABINET - ESPRESSO CUBBY WITH OPEN BACK - 18IN 455MM SB GC 23388 1 CABINET - BACKBAR - 18IN 460MM SB GC 23426 1 CABINET - WRM LOW - 30IN 760MM SB GC X0001 1 CUSTOM CABINET - DT POS UPPER CUBBY - FULL HEIGHT SB GC CABINET FINISH: WILSONART - FASHION GREY; MATCH CLOSELY TO BACK BAR TILE CABINETS 23709 1 CABINET - CBE UPPER CASEWORK IN-LINE - LF - 82IN SB GC CAFE 20383 1 FREESTANDING INLINE 2 UNIT SHORT - 72IN 1830MM - WHITE OAK WD0073 SB GC 23964 1 WASTE AND RECYCLE STATION THREE DROP - GOLDEN BLONDE AND WHITE PL0027 CP0002 SB GC COUNTERTOP 17807 8 COUNTERTOP - BACKBAR - 15IN 380MM SB GC 17809 1 COUNTERTOP - HAND SINK WITH LOW SPLASH STAINLESS - 15IN 380MM SB GC 17826 1 COUNTERTOP - DT POS - LF - 78IN 1980MM SB GC 17830 1 COUNTERTOP - POS - 82IN 2085MM SB GC 17843 1 COUNTERTOP - HANDOFF END CAP ROUNDED - LF SB GC 18721 1 COUNTERTOP - BREW WITH TRASH DROP - RF - 90IN 2285MM SB GC 20061 1 COUNTERTOP - ESPRESSO METRO - RF - 139IN 3530MM SB GC 20063 1 COUNTERTOP - FRONTBAR CAP - 139IN 3530MM SB GC 20273 1 COUNTERTOP - FRONTBAR MOP PLANAR - RF - 45IN 1145MM SB GC 21941 1 COUNTERTOP - BACKBAR - 30IN 760MM SB GC 21960 1 COUNTERTOP - DT WARMING - RF - 108IN 2745MM SB GC 23409 1 COUNTERTOP - CBE IN-LINE LF - 138IN 3505MM SB GC 23433 1 COUNTERTOP - WRM RF - 79IN 1930MM SB GC DIEWALL 17831 1 DIEWALL - POS - 82IN 2085MM SB GC 18859 1 DIEWALL - 45IN 1145MM SB GC 20064 1 DIEWALL - ESPRESSO - 139IN 3530MM SB GC FIT KIT 17894 3 FIT KIT - CABINET FILLER PANEL SB GC 17895 1 FIT KIT - BACKBAR COUNTERTOP SB GC 23409 1 FIT KIT - BACKBAR COUNTERTOP SB GC OTHER 11142 1 CORBEL SUPPORT - 24IN 610MM SB GC 11155 2 ESPRESSO MACHINE PUMP MOUNT - 10X10IN 255X255MM SB GC 18145 4 COUNTERTOP SUPPORT LEG SB GC 20066 1 SHROUD - 139IN 3530MM SB GC 20633 3 COUNTERTOP SUPPORT LEG SLIM SB GC PANEL 17832 1 PANEL - 82IN 2085MM SB GC 18860 1 PANEL - 45IN 1145MM SB GC 20065 1 PANEL - 139IN 3530MM SB GC CASEWORK FINISH SCHEDULE ENGINE ZONE MATERIAL DESCRIPTION FINISH CODE COMMENTS COMPOSITE - BRUSHED WARM GREY COUNTERTOPS - BACKBAR COMPOSITE - BRUSHED WARM GREY CP0056 COUNTERTOPS - ESPRESSO COMPOSITE - BRUSHED WARM GREY CP0056 COUNTERTOPS - FRONTBAR COMPOSITE - BRUSHED WARM GREY CP0056 COUNTERTOPS - SHROUD COMPOSITE - BRUSHED WARM GREY CP0056 METAL - FLAT BLACK POWDERCOAT CABINETS - DOOR PULL METAL - FLAT BLACK POWDERCOAT MT0028 METAL - STAINLESS STEEL - BRUSHED CABINETS - CABINET LEG METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA CABINETS - UNDERCOUNTER ICE BIN METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA COUNTERTOPS - HAND SINK METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED 16GA PLAM - MOTTLED BLACK CABINETS - DT POS CUBBY PLAM - MOTTLED BLACK PL0019 CABINETS - UNDERCOUNTER PLAM - MOTTLED BLACK PL0019 CABINETS - UPPER PLAM - MOTTLED BLACK PL0019 WOOD - WHITE OAK - ROUNDED SLAT - VERTICAL FINISH PANELS - FRONTBAR WOOD - WHITE OAK - ROUNDED SLAT - VERTICAL WD0073 MAD200 Revision Schedule Rev Date By Description WINDOW FILM SCHEDULE - "Z" DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS 19459 64 SF WINDOW FILM - FASARA - MILKY CRYSTAL GC GC GC TO PROVIDE SAMPLES TO STARBUCKS FOR APPROVAL FROM STARBUCKS DESIGN PRIOR TO PURCHASING AND INSTALLATION X19131 64 SF WINDOW FILM - SOLYX SXS-M6000 SILVER MIRROR OPAQUE FILM ON EXTERIOR GC GC GC TO PROVIDE SAMPLES TO STARBUCKS FOR APPROVAL FROM STARBUCKS DESIGN PRIOR TO PURCHASING AND INSTALLATION SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I602 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE FF&E SCHEDULES DATA DEVICE SCHEDULE - "A" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS AUDIO VISUAL 10005 1 MUSIC SYSTEM SB GC 10012 1 DT COMMUNICATION SYSTEM SB GC 10015 2 SPEAKER RECESSED - WHITE SB GC 10076 1 AMPLIFIER - 60W SB GC 22549 2 SPEAKER GRILLE RECESSED - BLACK SB GC 22725 1 DT DIGITAL PRODUCTION MONITOR SB GC PART OF RETAIL IT EQUIPMENT PACKAGE 22726 1 DT POS MONITOR ARM TRIPLE SURFACE MOUNTED SB GC PART OF RETAIL IT EQUIPMENT PACKAGE DATA 10002 1 COMPUTER MANAGER WORKSTATION SB GC 10007 1 PRINTER MANAGER WORKSTATION SB GC 18744 1 EQUIPMENT RACK WITH LOCK - 24IN 610MM SB GC 20294 4 IOT MODULE SB GC GRAPHICS - INTERIOR MENU 22970 4 MENU BOARD - DIGITAL DISPLAY - 44X25.25IN 1121X644MM - BLACK SB GC 22972 1 MENU BOARD - DIGITAL MENU BOARD MOUNTING BRACKET THREE SCREEN - BLACK SB GC 23021 1 MENU BOARD - ORDER STATUS BOARD MOUNTING BRACKET - BLACK SB GC POINT OF SALE 10008 2 POS - REGISTER WITH COMPACT CASH DRAWER SB GC 10014 3 POS PRINTER SB GC 10022 1 MONEY COUNTER SB GC 10029 6 POS BANK SB GC 10075 4 CUP LABELER SB GC 14677 1 POS - DT TENDERING REGISTER SB GC PART OF RETAIL IT EQUIPMENT PACKAGE 14678 1 POS - DT EXPEDITOR SB GC PART OF RETAIL IT EQUIPMENT PACKAGE SECURITY 10024 1 SAFE LH - 20X18X26IN 510X455X660MM SB GC 10028 1 SAFE BASE SB GC SPECIALTY EQUIPMENT SCHEDULE - "E" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS COOLING 10267 8 FRIDGE UNDERCOUNTER 1 DOOR - 27IN 685MM SB GC 11083 2 FRIDGE REACH IN 2 DOOR - 51X35IN 1295X890MM SB GC 12618 2 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF - 27IN 685MM SB GC 13682 1 FREEZER REACH IN 2 DOOR - 54IN 1370MM SB GC 20010 1 FRIDGE NITRO 2 TAP JT NITCOM LH SB GC KIT INCLUDES UNDERCOUNTER FRIDGE, FONT, TRAY, AND TUBING EQUIPMENT 10808 1 GRINDER DITTING KR1203 SB GC 12508 2 BLENDER QUIET MODEL ON COUNTER SB GC 15186 1 DISHWASHER HOT LOW STEAM SB GC 17564 1 BLENDER PITCHER RINSER WITH SENSOR SB GC 19742 2 ESPRESSO MACHINE MASTRENA II SB GC 20032 2 OVEN EIKON E2S - BLACK SB GC 21679 1 NITROGEN GENERATOR ELEMENT COMPACT SB GC 22885 1 BREWER CLOVER VERTICA DOUBLE SB GC 23380 1 BREWER CLOVER VERTICA INSTALL KIT SB GC 23381 1 BREWER CLOVER VERTICA CORD SB GC 23393 3 EQUIPMENT - CBE MILK DISPENSE BRACKET SLIDE SB GC 23419 3 MILK DISPENSER SB GC 23442 1 OVEN COMBI SB GC 24117 1 DRIP TRAY MILK AND ICE DISPENSE SB GC FOOD CASE 16239 1 FOOD CASE - ZEPHYR MINI - 54IN 1370MM SB GC 23444 1 FOOD CASE - WARMING WALL - 1000 SQUARE SB GC ICE 18029 1 ICE - BIN B110 SB GC BPF-1 ADAPTER KIT (011076103) REQUIRED WHEN PAIRING WITH 30" (760MM) ICE MACHINES 19278 2 ICE - BIN DROP IN 45LB 20KG HORIZONTAL SB GC 23182 1 ICE - MACHINE HMD1810RBT REMOTE COOLED SB GC 23338 1 ICE - BIN ADAPTOR FOLLETT B110H22H30 PEDESTAL TOP FOR B110 SB GC 23421 1 ICE - NUGGET ICE DISPENSER - SINGLE ICE MACHINE SB GC 23423 1 ICE - NUGGET ICE DIVERTER SB GC OTHER 10091 1 CUP DISPENSER TALL HOT VERTICAL SB GC 10099 2 RESTROOM TOILET PAPER HOLDER SB GC 10172 2 RESTROOM SEAT COVER DISPENSER SB GC 10396 1 CUP DISPENSER SHORT HOT VERTICAL SB GC 10501 1 FIRE EXTINGUISHER SB GC 10769 2 RESTROOM GRAB BAR VERTICAL - 18IN 455MM SB GC 10791 2 CUP DISPENSER GRANDE VENTI COLD VERTICAL SB GC 10855 2 CUP DISPENSER GRANDE VENTI HOT VERTICAL SB GC 10858 1 CUP DISPENSER TALL COLD VERTICAL SB GC 10859 2 RESTROOM GRAB BAR - 48IN 1220MM SB GC 10862 2 RESTROOM GRAB BAR - 36IN 915MM SB GC 10947 1 SOAP DISPENSER WALL MOUNTED SB GC 10976 2 RESTROOM TRASH SANITARY NAPKIN RECESSED SB GC 10977 1 PAPER TOWEL DISPENSER FULL SIZE - TRANSLUCENT GRAY SB GC 11130 6 CORNER GUARD - 0.375IN 10MM - ANODIZED ALUMINUM GC GC 13330 1 MOBILE CUP DISPENSER CADDY SB GC 13584 1 CUP DISPENSER TRENTA COLD VERTICAL SB GC 20403 6 KEG - 3GAL SB GC 22627 1 NITRO 2 TAP HANDLE WITH BADGE AND MOUNT KIT SB GC JOE TAP, FOR USE AT BACKBAR NITRO FONT 23420 2 REFRESHER DISPENSE SMALL SB GC STORAGE 10222 1 WIRE SHELF GRID AT SINK SB GC 10416 10 WORKROOM SHELVING - 36IN 915MM SB GC 10462 10 WORKROOM SHELVING POSTS SB GC 10698 1 MOP RACK WITH 3 HOLDERS SB GC 13578 2 DISHWARE DRYING RACK - 21IN 535MM SB GC 13834 1 BASE - 24X18IN 610X455MM SB GC ITEM PROVIDED BY PENTAIR FOR USE WITH WATER FILTRATON SYSTEM 17255 1 PASTRY TRAY CART - 60IN 1525MM SB GC 17264 1 ROLLING PASTRY TRAY THAW RACK - 20X26IN 510X660MM SB GC 21934 1 PASTRY TRAY RACK UNDERCOUNTER - 30IN 760MM SB GC 22212 1 WORKROOM SHELVING CART KIT SB GC 23445 2 PASTRY COOLING RACK WALL MOUNTED SB GC X0009 2 5 COMP LOCKER - 15X18IN 380X460MM SB GC FURNITURE SCHEDULE - "F" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS BANQUETTE 23009 3 BANQUETTE - WALLFLOWER - VARIABLE LENGTH - WHITE OAK WD0073 SB GC 23011 3 BANQUETTE - WALLFLOWER CUSHION SEAT AND BACK - VARIABLE LENGTH - CARAMEL BROWN NATURAL F0008 SB GC TK0057 1 BANQUETTE - WALLFLOWER INSIDE END VERTICAL STITCH STRAIGHT BACK - LEFT - WHITE OAK WD0073 - CARAMEL BROWN NATURAL F-0008 SB GC TK0063 1 BANQUETTE - WALLFLOWER INSIDE END VERTICAL STITCH STRAIGHT BACK - RIGHT - WHITE OAK WD0073 - CARAMEL BROWN NATURAL F-0008 SB GC CHAIR 17852 4 CHAIR - CAFE PYRAMID - BLACK AND BROWN ROPE MT0028 F0194 SB GC 20087 8 CHAIR - LOUNGE PYRAMID - BLACK AND BROWN ROPE MT0028 F0194 SB GC 21456 5 CHAIR - CAFE ASHER UPHOLSTERED BACK - WHITE OAK AND CARAMEL BROWN NATURAL WD0073 F0008 SB GC 22718 5 CHAIR - LOUNGE MOON - BLACK AND CARAMEL BROWN NATURAL MT0028 F0008 SB GC 22878 3 CHAIR - LOUNGE COMF - BLACK AND CARAMEL BROWN NATURAL MT0028 F0008 SB GC 23063 10 CHAIR - CAFE PEGGY UPHOLSTERED - WHITE OAK AND FERN GREEN WD0073 F0244 SB GC TK0077 1 CHAIR - MANAGERS WORKSTATION SB GC STEELCASE SERIES ONE ARMLESS DESK TK0053 1 DESK - MANAGERS WORKSTATION SHELVES - 48IN 1220MM SB GC TK0076 1 DESK - MANAGERS WORKSTATION - 48X24X27IN 1220X610X685MM SB GC MIRROR 14350 2 MIRROR - RESTROOM ANGLED- 18X36IN 455X915MM SB GC OTHER 10756 2 COAT HOOK 1 PRONG SQUARE - 2IN 50MM - SST TK0051 1 COAT HOOK STRIP - 30IN 760MM SB GC BLACK FINISH OUTDOOR X1010 2 WEST ELM PORTSIDE OUTDOOR DINING TABLE SB GC X1011 2 WEST ELM PORTSIDE OUTDOOR DINING BENCH SB GC STORAGE TK0078 1 FILE MOBILE PEDESTAL WITH CUSHION AND LOCK SB GC TK0079 1 MANAGERS DESK CART - 24X20IN 610X510MM SB GC TABLE 20128 2 TABLE - OCCASIONAL COFFEE CAMERON - FLAT BLACK MT0028 SB GC 21449 9 TABLE - BASE CAFE HEIGHT BOTTLE - FLAT BLACK MT0028 SB GC 21453 1 TABLE - BASE ACCESSIBLE BOTTLE - FLAT BLACK MT0028 SB GC 21800 1 TABLE - TOP ACCESSIBLE ROUND EDGE OBLONG - 48X24IN 1220X610MM - WHITE OAK WD0073 SB GC 21842 4 TABLE - TOP ROUND EDGE ROUND - 24IN 610MM - WHITE OAK WD0073 SB GC 21848 5 TABLE - TOP ROUND EDGE SQUARE - 24IN 610MM - WHITE OAK WD0073 SB GC TK0027 5 TABLE - OCCASIONAL SIDE COCO SB GC X5050 1 WEST ELM - ORGANIC MODULAR TABLE - BLACK ON ASH - SMALL SB GC WINDOW TREATMENT 22487 16 ROLLER SHADE - DARK GREY - 5PC OPEN SB GC GRAPHICS AND ARTWORK SCHEDULE - "G" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS GRAPHICS - ARTWORK 23331 1 ASUKA WATANABECHROMATIC HACIENDA ALSACIA - CORAL SB GC ARTWORK PRINTED ON SUBSTRATE. INSTALLED AS WALLCOVERING. 23878 1 QUETZAL'S FLIGHT CARPENTER COLLECTIVE MURAL SB GC QUETZAL'S FLIGHT - PAINTABLE EXTERIOR MURAL FOR DARK WALLS Revision Schedule Rev Date By Description TRUE / TUC-27-LP-HC VITAMIX: SPRAYPARK ELEMENT7: NG3000 SERIES DONLIM: CM9700 PENTAIR: SHURFLO EV9910-00 DONLIM: CM9700 DONLIM: MILK MACHINE IP220238 CONVOTHERM OES 10.10 MINI eT FLEXZONE 4 TIER FXZNA10S4S-SF61 ELKAY | LID-74763A\FSP211635 FOLLETT IMDV-2CM SERIES TRUE / TG2R-2S-HC TRAULSEN / UHT27-R0-0300-ZSB02 TRUE / T-49F-HC STAR DITTING / KR1203 VITAMIX: 062911 HOBART: THERMOPLAN: M2-CS MERRYCHEF: E2SDBMV6DFL2SBUS HORIZON ELITE | HMD1810RBT FOLLETT | ID50 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2024 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2024.01.29 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: GRAPHITE DESIGN GROUP, LLC, ARCHITECTS 1807 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 (206) 224-3335 I603 102442-001 05-03-2024 YE L M & K I L L I O N 93 7 Y E L M A V E W YE L M , W A 9 8 5 9 7 84311 ALINA PINCHUK GRAPHITE GRAPHITE PLUMBING & LIGHTING SCHEDULES NOTE: THE SCHEDULES ON THIS SHEET ARE FOR OWNER'S ORDERING PURPOSES ONLY. REFER TO ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION AND SPECIFICATIONS. LIGHTING FIXTURE SCHEDULE - "L" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS EXIT 19049 2 LED EXIT SIGN RECESSED - WHITE AND RED SB GC INTEGRATED LED PENDANT 20831 3 PENDANT - TALA KNUCKLE - OAK SB GC 6 W LED, AS PACKAGED DROP LENGTH: 2'-10", 3'-2", AND 3'-6" RECESSED CAN 21772 76 CAN - LED ADJUSTABLE RECESSED - 3IN 75MM - WHITE - 800LM FLOOD SB GC INTEGRATED LED SCONCE 20750 2 SCONCE - KUZCO PLUTO TRIPLE - VINTAGE BRASS SB GC AS PACKAGED: 1X LED G16 5W E26 BASE X2851 2 SCONCE - SCHOOLHOUSE ELECTRIC ALLEGHENY - BUTTERSCOTCH SB GC AS PACKAGED: 1X LED G16 5W E26 BASE STRIP 22216 17 STRIP - LED TAPE IN HOUSING - VARIABLE LENGTH - WHITE - 350LM PER FT SB GC INTEGRATED LED FIELD TRIMMABLE TO 0.9IN LENGTHS, 21' AT ART WALL, 26' AT UNDERSIDE OF FRONT COUNTER 22400 1 STRIP - LED TAPE FLEXIBLE - VARIABLE LENGTH - 250LM PER FT SB GC INTEGRATED LED 6' 10" AT UNDERSIDE OF UPPER CASEWORK PER RCP TROFFER 15057 9 TROFFER - LED RECESSED - 24X48IN 600X1200MM - WHITE - 4000LM SB GC INTEGRATED LED PLUMBING FIXTURE SCHEDULE - "P" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS DRAIN 10294 7 DRAIN - FLOOR SINK SQUARE - 12IN 305MM SB GC 10594 3 DRAIN - SQUARE - 5IN 125MM GC GC 10726 7 DRAIN - GRATE HALF SQUARE - 12IN 305MM SB GC ZURN FD2375 HALF GRATE FAUCET 10152 1 FAUCET - DOUBLE LABORATORY WITH BENT RISER SPOUT SB GC 10153 4 FAUCET - WATER TOWER - 12IN 305MM SB GC 10215 2 FAUCET - DOUBLE LABORATORY WITH SWING SPOUT SB GC 10447 1 FAUCET - PRE RINSE SPRAYER WALL MOUNTED SB GC 10597 1 FAUCET - SINGLE HANDLE SB GC 10804 1 FAUCET - PRE RINSE SWING SPOUT SB GC 10922 1 FAUCET - MOP SINK WALL MOUNTED SB GC 11003 2 FAUCET - METERED SB GC 13588 1 FAUCET - HAND SINK WALL MOUNTED SB GC 22642 3 FAUCET - INSTANTHOT SYSTEM 2 BUTTON WITH BOILER AND BRACKET SB GC KIT INCLUDES FONT, UNDERCOUNTER BOILER AND BOILER BRACKET FOR SIDE PANEL MOUNTING. BRACKET CAN BE FLOOR MOUNTED USING SET OF (4) STAINLESS STEEL LEGS, ORDERED SEPARATELY THROUGH VENDOR. TK0042 2 FAUCET - RESTROOM BRADLEY LOOP WB1 WITH SOAP AND DRYER SB GC FINISH BRUSHED BRASS. INCLUDED AS PART OF THE SINK FILTER 12501 1 FILTER - RO SYSTEM 600GPD SB GC 12507 1 FILTER - RO SYSTEM STORAGE TANK RO40 SB GC 12896 1 FILTER - BRINE TANK SB GC 12899 2 FILTER - POLY GLASS VESSEL SB GC 13076 1 FILTER - PREFILTRATION SYSTEM SB GC 13082 1 FILTER - WATER SOFTENER TWIN SB GC 23355 1 FILTER - FILTRATION BOOSTER PUMP SB GC OTHER 11109 1 WATER HEATER TANK ELECTRIC GC GC TK0045 1 RESTROOM BRADLEY ENCLOSED ACCESS PANEL DOUBLE SINK SB GC BLACK FINISH PANEL SINK 10549 1 SINK - RINSE DROP IN SST - 12X20IN 305X510MM SB GC 10995 1 SINK - MOP - 24X24IN 610X610MM SB GC 13264 1 SINK - 3 COMP WORK SST - 93IN 2350MM SB GC 14688 1 SINK - HAND WITH SIDE SPLASH WALL MOUNTED SST SB GC 17565 1 SINK - RINSE WITH DRAINBOARD - 15X27IN 380X685MM SB GC 18743 1 SINK - WATER FILLING STATION - 36X24IN 915X610MM SB GC 22768 2 SINK - COUNTERTOP RINSER WITH WATER TOWER - 26X9IN 660X235MM SB GC TK0040 1 SINK - RESTROOM BRADLEY DOUBLE LVQD2 WALL MOUNTED SB GC FINISH SANDSTONE. BRUSHED BRASS FAUCET, BLACK ACCESS PANEL TOILET 22558 2 TOILET - TANKLESS AUTOMATIC SINGLE FLUSH GC GC Revision Schedule Rev Date By Description GENERAL NOTES SCOPE THE INTENT OF THE DRAWINGS AND PROJECT MANUAL IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. SITE EXAMINATION THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES, THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. ABBREVIATIONS AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION APPROX APPROXIMATE BLDG BUILDING CKT CIRCUIT CLG CEILING CM STARBUCKS CONSTRUCTION MANAGER CONST CONSTRUCTION CW COLD WATER CXA COMMISSIONING AGENT DEG DEGREES DL LIGHTS WITHIN DAYLIGHT ZONE DM STARBUCKS DESIGN MANAGER DN DOWN DTL DETAIL DWG(S)DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR ECP EQUIPMENT CONTROL PAC EG EXHAUST GRILLE ELEC ELECTRICAL EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ETR EXISTING TO REMAIN EXT EXTERIOR F&I FURNISH & INSTALL FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER, INSTALLED BY OWNER FLR FLOOR FT FOOT/FEET GC GENERAL CONTRACTOR GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HR HOUR HVAC HEATING, VENTILATION, AIR CONDITIONING HW HOT WATER LCP LIGHTING CONTROL PANEL LL LANDLORD LS LIGHT SENSOR PHOTOCELL LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, AND PLUMBING MFG MANUFACTURER MIN MINIMUM NL NIGHTLIGHT NTS NOT TO SCALE OCP OVERCURRENT PROTECTION REF REFERENCE REQ(’D)REQUIRE(D) REV REVISION SF SQUARE FEET SHT SHEET SPECS SPECIFICATION(S) SST STAINLESS STEEL TEL TELEPHONE TEMP TEMPORARY TYP TYPICAL UC UNDER COUNTER UNO UNLESS NOTED OTHERWISE WH WATER HEATER WP WEATHER PROOF COMMUNICATION SYSTEM NOTES CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE) CONDUIT INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE STREET FEED TO THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE PROVIDER. WIRELESS NETWORK NOTES CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED BY THE VENDOR FOR FIBER OR BROADBAND CONNECTIONS. T1 AND ETHERNET EXTENSION CABLING IS PROVIDED BY THE STARBUCKS (TELEPHONE/ NETWORK) CABLING VENDOR. COORDINATE WITH STARBUCKS. MUSIC SYSTEM NOTES MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR REFLECTED CEILING PLANS AND IN COORDINATION WITH ALL PLANS, DETAILS AND MANUFACTURER'S INSTALLATION REQUIREMENTS. INSTALL AND CONNECT OWNER FURNISHED WIRING SYSTEM BETWEEN ALL SPEAKERS AND THE OWNER PROVIDED MUSIC SYSTEM. SET WATTAGE TAP ON EACH SPEAKER'S ROTARY SWITCH PER TAP SETTINGS NOTED ON PLANS. POS \ DATA LINE NOTES STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER SCHEDULES DELIVERY OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE DELIVERY. DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL CABLE RUNS PRIOR TO CABLE INSTALL DATE. STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS VENDOR. THIS GROUP MAY BE CONTACTED AT: NEWSTORES@STARBUCKS.COM . SECURITY SYSTEM NOTES STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY AND INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF SECURITY SYSTEM FOR FOUR (4) TIMES; 1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE INSTALLER PRIOR TO DRYWALL INSTALLATION. 2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS PANEL, KEYPAD AND SENSORS. 3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR. 4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND TRAIN PARTNERS AFTER POS INSTALL. SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. TELEPHONE SYSTEM NOTES IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE STANDARD SINGLE LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL CONTRACTOR SHALL CONTACT THE STARBUCKS CONSTRUCTION MANAGER PRIOR TO BEGINNING CONSTRUCTION TO ORDER THE ADDITIONAL TELEPHONE LINE(S). REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY TO THE STARBUCKS CONSTRUCTION MANAGER. CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE EXISTING, WORKING TELCO FACILITIES TO THE BUILDING OR THAT LANDLORD HAS FURNISHED AND INSTALLED ONE (1) 2" (51MM) MIN. (ENTRANCE) CONDUIT INCLUDING PULL STRING FROM TELCO STREET FEED LINE TO THE BUILDING AS IDENTIFIED BY THE PHONE COMPANY. NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF FACILITIES OR CONDUIT AND PULL STRING ARE NOT INSTALLED. GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN. CONDUIT WITH PULL STRING FROM THE DATA RACK TO THE DEMARC (TELCO TO CUSTOMER HAND OFF EQUIPMENT) WHEN THE DEMARC IS MORE THAN 10' FROM THE DATA RACK. DISTANCES LESS THAN 10' WILL NOT REQUIRE CONDUIT. PROVIDE A 3-POSITION GROUND LUG, GROUNDED WITH #6 AWG GROUND WIRE, IF REQUIRED BY TELEPHONE COMPANY. ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE/NETWORK CABLING VENDOR. GENERAL ELECTRICAL NOTES 1.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE PROJECT MANUAL. 2.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD. 3.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE- ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. 4.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND 5:00AM. 5.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETE SECURITY, PHONE, POS AND DATA SYSTEMS. SEE MANAGER WORKSTATION AND BAR POINT OF SALE (POS) POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. PROVIDE END-TO-END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL STRING WITH CONDUIT SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT BAR", ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED CONDUIT ENDS. 6.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 7.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER FOR APPROVAL. 8.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. CARBON MONOXIDE (CO) DETECTOR NOTES COORDINATE INSTALLATION OF CARBON MONOXIDE (CO) DETECTOR DEVICE(S) AND LOW VOLTAGE WIRING WITH STARBUCKS SECURITY VENDOR FOR NEW STORES, RELOCATIONS AND MAJOR RENOVATIONS, IF IN VENDOR SCOPE. VENDOR TO PROVIDE AND INSTALL DEVICE(S) IN BOH AND FOH (AS APPLICABLE PER STARBUCKS STANDARDS). FIRE ALARM SYSTEM NOTES IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE ALARM MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS SPECIFIED IN THE LEASE AGREEMENT, THE CONTRACTOR IS TO NOTIFY GNOC IMMEDIATELY THAT FIRE ALARM LINES ARE NEEDED. STARBUCKS PREFERRED FIRE ALARM SERVICE PROVIDER, STANLEY, IS TO BE CONTACTED BY THE CONSTRUCTION MANAGER TO INSTALL FIRE ALARM PANEL AND/OR MONITORING SERVICE AS REQUIRED. ENERGY MANAGEMENT SYSTEM (EMS) THE GENERAL CONTRACTOR SHALL INSTALLATION VENSTAR SURVEYOR LCP AND EMS SYSTEM . PRIOR TO LAST WEEK OF CONSTRUCTION, IF NEEDED, FURNISH AND INSTALL TEMPORARY THERMOSTATS AND SENSORS, AND ROUTE ALL LOW VOLTAGE WIRING THROUGH EC PROVIDED CONDUITS (COORDINATE WITH ELECTRICAL). FURNISH AND INSTALL RACEWAYS WITH PULL STRINGS AND JUNCTION BOXES FOR THERMOSTAT(S) AND SENSOR(S). SET RESTROOM OCCUPANCY SENSOR TO 15 MINUTE ‘ON’ DURATION IN SINGLE OCCUPANT RESTROOM AND TO 20 MINUTE ‘ON’ DURATION IN MULTI-OCCUPANT RESTROOM UNLESS JURISDICTION REQUIREMENTS STATE OTHERWISE. COORDINATE WITH DRAWINGS AND LCP VENDOR FOR DEVICE LOCATIONS. VENDOR SHALL COMMISSION CONTROLS. THE GENERAL CONTRACTOR IS TO COMPLETE FINAL CONNECTION AFTER DATA RACK AND NETWORK INSTALLATION. THE GENERAL CONTRACTOR IS TO CONTACT LCP VENDOR TO VERIFY SYSTEM OPERATION AND TROUBLESHOOT IF REQUIRED. LANDLORD REQUIREMENTS PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD / BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS. IF LANDLORD / BUILDING OWNER DOES HAVE REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH REQUIREMENTS AND ADHERE TO THEM. WHERE LANDLORD / BUILDING OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS (IN THE OPINION OF THE ENGINEER). LANDLORD / BUILDING OWNER REQUIREMENTS SHALL GOVERN. SYSTEM COMMISSIONING CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED, NEEDED AND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE COMPRISED OF THREE DISTINCT EFFORTS: 1)SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING INSTALLATION VERIFICATION AND CORRECT DISCLOSED DEFICIENCIES; 2)PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS CXA; 3)CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE TESTING AND SUBMIT REPORTS. CONTRACTOR SHALL PERFORM AND PROVIDE THE FOLLOWING: A.SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE NOT LIMITED TO DOMESTIC HOT WATER GENERATION, HVAC SYSTEMS, ROOFTOP UNITS, EXHAUST FANS, HVAC CONTROLS, LIGHTING CONTROLS, AIR CURTAINS, BUILT-IN REFRIGERATION EQUIPMENT, AND RENEWABLE ENERGY SYSTEMS. B.CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA. CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM IN THE SCHEDULE OF VALUES. C.CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER’S REQUIREMENTS AND ALL CONTRACT DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION VERIFICATION. D.INSTALLATION VERIFICATION SHALL BE PERFORMED BY STARBUCKS CXA. CONTRACTOR SHALL SUPPORT STARBUCKS CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY. PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS INSTALLED CORRECTLY. E.CONTRACTOR SHALL BE READILY AVAILABLE DURING INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE. F.ALL HVAC, EXHAUST FAN, AND AIR CURTAIN EQUIPMENT SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR’S TESTING, ADJUSTING AND BALANCE AGENT( SEE TESTING, ADJUSTING AND BALANCING) AFTER THE SYSTEM IS VERIFIED TO BE COMPLETE AND CORRECT BY STARBUCKS CXA, IN ACCORDANCE WITH THE REQUIREMENTS OF THESE DOCUMENTS.ALL HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE PLANS AND PROJECT MANUAL. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN TESTING AND AIR BALANCE REPORT CONFORMING TO THE REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE INFORMATION SPECIFIED, ETC. TO THE STARBUCKS CXA IMMEDIATELY UPON COMPLETION OF THE WORK. G.CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL PERFORMANCE TESTING PRIOR TO STARTING TESTING. CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER EXECUTION OF HVAC CONTROL AND LIGHTING SEQUENCES; INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, TEMPERATURE, SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT AS NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WILL RECORD THE EQUIPMENT OPERATION AND RESPONSE TO TESTING SEQUENCES AND PREPARE A LIST OF ANY DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS, ROOFTOP AND SPLIT TYPE, CONDENSING UNITS,EXHAUST FANS, LIGHTING CONTROLS, ETC. DELIVERABLES: PROVIDE COMPLETED COPIES OF ALL START UP REPORTS, FILLED OUT ON THE MANUFACTURER'S FORMS, TO THE STARBUCKS CXA. H.CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. I.CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE- TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS CXA DURING INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES FOUND IN THE SYSTEM DURING ANY AND ALL RE-TESTING. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES: FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TEST RESULTS. J.CONSTRUCTION AND POST CONSTRUCTION TESTING: ADDITIONAL TESTING MAY BE REQUIRED AND OTHER PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT, DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS DIRECTED BY STARBUCKS CXA. A. B. C. 1) 2) 3) 4) 5) THE EMERGENCY POWER SYSTEM SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM WHICH IS TO PROVIDE CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN 1 1/2 HOUR IN CASE OF PRIMARY POWER LOSS. CONTINUED ILLUMINATION IS TO BE PROVIDED FROM STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR AND THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER 27. (1013.6.3) E. EGRESS LIGHTING NOTES CONN CONNECTION NL J OS JUNCTON BOX HOMERUN FOR CIRCUIT CONCEALED IN CEILING OR WALL. 2#12 & 1#12 GND., 3/4" C., UNLESS OTHERWISE NOTED. 3 ELECTRICAL SYMBOL LEGEND PE RECEPTACLE: DUPLEX SWITCH RECEPTACLE: DUPLEX - GFCI BELOW COUNTERTHREE-WAY SWITCH RECEPTACLE: QUAD SPECIAL RECEPTACLE GROUNDING ELECTRODE CONNECTIONTELEPHONE NIGHTLIGHTING 24HR/DAY S THERMOSTAT SENSOR PHOTOELECTRIC CELL DIMMER SWITCH SPEAKER RECEPTACLE: DATA RECEPTACLE: FLOOR DUPLEX RECEPTACLE: QUAD - INDIVIDUAL BRANCH CIRCUIT WIFI ACCESS POINT D CEILING MOUNTED OCCU- PANCY SENSOR DS DAYLIGHT SENSOR CL CURRENT LIMITER RECEPTACLE: CEILING DUPLEX RECEPTACLE: GFCI WITH WEATHERPROOF IN-USE COVER WHERE ALSO NOTED 'WP' GFCI GFCI WP OS RECEPTACLE: TAMPER RESISTANT DUPLEX T FIRE ALARM CONTROL PANEL SMOKE DETECTOR PULL STATION HORN/STROBE EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED INTERNALLY ILLUMINATED EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. EXTERNALLY ILLUMINATED EXIT SIGNS SHALL COMPLY WITH THE GRAPHICS AND POWER SOURCE REQUIREMENTS IN SECTIONS 1013.6.1 AND 1013.6.3 RESPECTIVELY. WHEN THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 LUX). (1013.3) D. ANYTIME A BUILDING OR A PORTION OF A BUILDING IS OCCUPIED, THE MEANS OF EGRESS SERVING THE OCCUPIED PORTION SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT CANDLE (11 LUX) AT THE WALKING SURFACE LEVEL. (1008.2.1) THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY THE PREMISE'S ELECTRICAL SUPPLY, IN THE EVENT OF POWER SUPPLY FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM FOR THE FOLLOWING AREAS. (1008.3): AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS. CORRIDORS, INTERIOR EXIT STAIRWAYS & RAMPS AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1028.1 IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.2.2 EXIT DISCHARGE DOORWAYS IN BUILDING REQUIRED TO HAVE TWO OR MORE EXITS. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT CANDLE (11 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOT CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. A MAXIMUM TO MINIMUM ILLUMINATION UNIFORMITY RATION OF 40:1 SHALL NOT BE EXCEEDED. (1008.3.5) RECEPTACLE WITH USB CHARGING PORT PROVIDE UL FEDERAL SPECIFICATION CERTIFIED TAMPER-RESISTANT DUPLEX RECEPTACLE WITH USB CHARGING CAPABILITIES. FEATURES SHALL INCLUDE OVERALL 3.1A USB CHARGING CAPABILITY, AUTO GROUND CLIPS, ZINC-PLATED GROUND TERMINAL SCREW AND TRIPLE-WIPE BRASS CONTACTS. PASS & SEYMOUR #TR5362USB* OR EQUAL *- FINISH COLOR SHALL BE AS SPECIFIED ON ARCHITECTURAL DRAWINGS OR AS DIRECTED BY OWNER'S REPRESENTATIVE. MOTION (VACANCY) SENSOR SWITCHVS MOTION (OCCUPANCY) SENSOR SWITCH SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-001 ELECTRICAL NOTES ELECTRICAL SPECIFICATIONS 1.FURNISH AND INSTALL A COMPLETELY WIRED AND OPERATIONAL ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN, INCLUDING BUT NOT LIMITED TO, THESE MAJOR ITEMS. A.LIGHTING FIXTURES AS INDICATED AND SPECIFIED ON THE PLANS. B.ELECTRICAL PANELS, SERVICE, CONDUIT, WIRING, ETC., FOR ALL OUTLETS AND EQUIPMENT. C.TELEPHONE OUTLETS AND CONDUIT AS INDICATED. PART I - GENERAL A. CONDITIONS B. RELATED WORK BY OTHERS 1.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, TRENCH, AND BACKFILL FOR ELECTRICAL SERVICE ENTRANCE FROM THE MAIN SERVICE TO UTILITY POINT OF ELECTRICAL SERVICE. ELECTRICAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE ELECTRICAL SERVICE ENTRANCE WITH SERVING UTILITY COMPANY. 2.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, TRENCH, AND BACKFILL FOR PRIMARY PHONE AND CATV SERVICE FROM THE TELEPHONE TERMINAL BOARD OR CABINET TO THE PHONE COMPANY AND CATV COMPANY POINT OF SERVICE. C. CODES, REGULATIONS, AND STANDARDS 1.THE INSTALLATION SHALL COMPLY WITH APPLICABLE LOCAL AND STATE CODES AND ORDINANCES,WITH THE REGULATIONS OF THE CURRENTLY ACCEPTED EDITION OF THE NATIONAL ELECTRIC CODE AND WITH THE REQUIREMENTS OF THE POWER,TELEPHONE, AND CATV COMPANIES FURNISHING SERVICES TO THIS INSTALLATION. 2.ELECTRICAL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH THE NECA INSTALLATION STANDARDS TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. 3.ALL WORK MATERIALS,A ND EQUIPMENT SHALL CONFORM TO THE CURRENTLY ACCEPTED EDITION OF ALL APPLICABLE NATIONAL, STATE, AND CITY CODES AND ORDINANCES. THE FOLLOWING INDUSTRY STANDARDS, SPECIFICATIONS, AND CODES ARE MINIMUM REQUIREMENTS: A.THE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION STANDARDS. B.THE NATIONAL ELECTRICAL CODE, INCLUDING LOCAL AMENDMENTS. C.UNDERWRITER LABORATORIES INCORPORATED STANDARDS. D.AMERICAN NATIONAL STANDARDS INSTITUTE. D. INSPECTION OF SITE 1.PRIOR TO SUBMITTING A BID FOR ELECTRICAL WORK, THE CONTRACTOR SHALL VISIT THE SITE OF THE PROPOSED CONSTRUCTION AND SHALL THOROUGHLY ACQUAINT HIMSELF WITH EXISTING UTILITIES, AND WORKING CONDITIONS TO BE ENCOUNTERED, ETC. ALLOWANCE WILL NOT BE MADE FOR NONCOMPLIANCE WITH THIS CONDITION AFTER BIDDING. 2.ELECTRICAL INSTALLATION SHALL MEET THE EXISTING CONDITIONS. 3.CONTRACTOR SHALL VERIFY, WITH OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING BID, ALLOWABLE WORKING HOURS, EMPLOYEE PARKING AREAS, MATERIAL DELIVERY, STORAGE REQUIREMENTS, DEMOLITION AND REMOVAL OF CONSTRUCTION DEBRIS, AS WELL AS DAILY CLEAN UP REQUIREMENTS. INCLUDE ALL COSTS IN BID FOR DUST BARRIERS, DUMPSTERS, ETC. AS REQUIRED FOR THE DURATION OF THE PROJECT. PERFORM ALL WORK AS DIRECTED BY OWNER'S REPRESENTATIVE AND ARCHITECT. F. CLEANUP 1.KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS, OR RUBBISH CAUSED BY EMPLOYEES OR WORK UNDER THIS DIVISION OF THE SPECIFICATIONS. AT THE COMPLETION OF THE WORK REMOVE ALL SURPLUS MATERIALS, TOOLS, ETC., AND LEAVE THE PREMISES BROOM-CLEAN. G. EXCAVATION 1.PERFORM ALL EXCAVATION AND BACK BACKFILING REQUIRED FOR WORK PERFORMED UNDER THIS DIVISION OF THE SPECIFICATIONS. USE EXCAVATED MATERIALS FOR BACKFILL UNLESS OFF SITE MATERIALS ARE DEEMED NECESSARY. H. DRAWINGS 1.THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE ELECTRICAL WORK DATA PRESENTED ON THESE DRAWINGS ARE AS ACCURATE AS PLANNING CAN DETERMINE, BUT FIELD VERIFICATION OF ALL DIMENSIONS, LOCATIONS, LEVELS, ETC., TO SUIT FIELD CONDITIONS IS REQUIRED. REVIEW ALL ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS AND ADJUST ALL WORK TO MEET THE REQUIREMENTS OF CONDITIONS SHOWN. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DISCREPANCIES BETWEEN DIFFERENT PLANS, OR BETWEEN DRAWINGS AND SPECIFICATIONS, OR REGULATIONS AND CODES GOVERNING THE INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE THE DATE OF BID OPENING. IF DISCREPANCIES ARE NOT REPORTED, THE CONTRACTOR SHALL BID THE GREATER QUANTITY OR BETTER QUALITY, AND APPROPRIATE ADJUSTMENTS WILL BE MADE AFTER CONTRACT AWARD. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD MEASURE AND CONFIRM MOUNTING HEIGHTS AND LOCATION OF ELECTRICAL EQUIPMENT WITH RESPECT TO COUNTERS, RADIATION, ETC. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS, USE ACTUAL BUILDING DIMENSIONS. 2.IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE ENGINEER RESERVES THE RIGHT TO ALLOW OTHER METHODS AND MATERIALS NOT REFLECTED HEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE TO REQUEST THE ENGINEER WAIVE THE STANDARDS TO ALLOW ALTERNATE MEANS AND METHODS PRIOR TO BEGINNING THE PROJECT. CONTRACT DOCUMENT REVISIONS TO ACCOMMODATE INSTALLED CONDITIONS, WITHOUT PRIOR APPROVAL, WILL RESULT IN ADDITIONAL DESIGN CHARGES TO THE CONTRACTOR. 3.VERIFY EXACT LOCATION OF ALL DEVICES, JUNCTION BOXES, LIGHTING FIXTURES, ETC. WITH ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS PRIOR TO INSTALLATION. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND OTHER EQUIPMENT REQUIRING ELECTRICAL CONNECTION PRIOR TO ROUGH-IN. EVERY OUTLET HEIGHT SHALL BE VERIFIED ON EACH WALL WITH THE INTERIOR PLANING AND DESIGN DRAWINGS. COORDINATE WITH CABINET SHOP DRAWINGS TO ENSURE PROPER HEIGHT AND LOCATION WITH RESPECT TO MILLWORK, EQUIPMENT, ETC. E. STORAGE AND HANDLING OF MATERIAL 1.DELIVER MATERIALS AND EQUIPMENT TO THE PROJECT IN THE MANUFACTURER'S ORIGINAL, UNOPENED, LABELED CONTAINERS. PROTECT AGAINST MOISTURE, TAMPERING, OR DAMAGE FROM IMPROPER HANDLING OR STORAGE. CONTRACTOR SHALL PROTECT AND BE RESPONSIBLE FOR ANY DAMAGE TO WORK OR MATERIALS UNTIL FINAL ACCEPTANCE BY THE OWNER, AND SHALL MAKE GOOD WITHOUT COST TO THE OWNER, AND DAMAGE OR LOSS THAT MAY OCCUR DURING THIS PERIOD. 2.ARRANGE FOR TIMELY DELIVERY OF MATERIALS AND EQUIPMENT TO THE JOB SITE IN ORDER TO MINIMIZE THE LENGTH OF TIME BETWEEN DELIVERY AND INSTALLATION. 3.COVER AND PROTECT ANY MATERIAL WHICH MAY BE AFFECTED BY THE WEATHER WHILE IN TRANSIT OR STORED AT THE PROJECT SITE. ANY MATERIAL FOUND DEFECTIVE OR NOT INSTALLED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS MAY BE REJECTED BY THE ENGINEER. J. COOPERATION WITH OTHER CONTRACTORS 1.COOPERATE WITH THE OTHER TRADES SO THAT THE INSTALLATION OF THE ELECTRICAL OUTLETS AND EQUIPMENT WILL BE PROPERLY COORDINATED. CONDUIT, LIGHTING FIXTURES, AND OTHER EQUIPMENT LOCATIONS SHALL BE CHECKED WITH OTHER TRADES TO AVOID CONFLICT WITH THE PIPING, DUCTWORK, STEEL, BEAMS, OR OTHER OBSTRUCTIONS. CAREFULLY CHECK THE LOCATIONS OF THE OUTLET BOXES AND DETERMINE THAT THEY HAVE NOT BEEN DISTURBED DURING THE INSTALLATION OF MATERIALS OF OTHER TRADES. 2.COORDINATE THE LOCATION OF THE TRENCHES AND CONDUITS FOR ELECTRICAL AND TELEPHONE UTILITY SERVICES WITH THE GENERAL CONTRACTOR. 3.COORDINATE HVAC EQUIPMENT CONNECTION REQUIREMENTS WITH HVAC CONTRACTOR. PART II - PRODUCTS AND EXECUTION A.MATERIALS 1.ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE NEW AND OF QUALITY AS SPECIFIED ON THE PLANS OR SPECIFICATIONS AND MUST CARRY THE UNDERWRITER'S LABORATORIES OR OTHER RECOGNIZED TESTING FACILITY AS ALLOWED BY AUTHORITY HAVING JURISDICTION. APPROVAL COVERING THE PURPOSE FOR WHICH THEY ARE USED, IN ADDITION TO MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. B. CONDUIT 1.RACEWAY SYSTEMS ARE SHOWN DIAGRAMMATICALLY. ACTUAL LOCATION AND ROUTING OF ALL, SHALL BE DETERMINED BY CONTRACTOR TO SUIT FIELD CONDITIONS. ELECTRICAL INSTALLATION SHALL MEET THE EXISTING CONDITIONS. 2.PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY NEC ARTICLE 310 REQUIREMENTS. 3.CONTRACTOR SHALL PROVIDE ALL RACEWAY SYSTEMS INDICATED ON THE DRAWING PER NEC REQUIREMENTS AND GENERAL NOTES. ANY DEVIATION FROM THE WIRING METHODS INDICATED SHALL BE ALLOWED ONLY BY SPECIFIC WRITTEN APPROVAL FROM EITHER THE ARCHITECT, ENGINEER OR OWNER. CONTRACTOR'S BID SHALL INCLUDE ALL COSTS FOR RACEWAY SYSTEMS AS SPECIFIED UNLESS SPECIFIC WRITTEN APPROVAL FOR AN ALTERNATIVE WIRING METHOD IS OBTAINED FROM EITHER THE ARCHITECT, ENGINEER OR OWNER AND IS SUBMITTED AS PART OF CONTRACTOR'S FORMAL BID PROPOSAL. 4.WHERE ALLOWED, MC CABLE MAY BE INSTALLED PER NEC ARTICLE 330. WHERE MULTIPLE CABLES ARE ROUTED ADJACENT TO EACH OTHER (BUNDLED), A MINIMUM SEPARATION OF ONE (1) CABLE DIAMETER (LARGEST) SHALL BE REQUIRED. A.PLASTIC CABLE TIES SHALL NOT BE USED AS A MEANS OF SUPPORT FOR MC CABLE. USE ONLY APPROVED CABLE SUPPORTS PER CABLE MANUFACTURER'S INSTALLATION REQUIREMENTS. 5.ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC CONDUIT EXCEPT AS PERMITTED BELOW. RGS, WITH A 20 MIL PVC COATING WILL BE USED WHEN IN CONTACT WITH EARTH. IMC MAY BE USED IN INDOOR LOCATIONS NOT IN CONTACT WITH THE EARTH. EMT MAY BE USED IN INDOOR LOCATIONS NOT IN CONTACT WITH EARTH, NOT IN CONCRETE SLABS OR WALLS AND NOT SUBJECT TO DAMAGE. PVC MAY BE USED IN OR BELOW CONCRETE AND DIRECT BURIED IN EARTH. LIQUID-TIGHT FLEXIBLE STEEL CONDUIT SHALL BE FOR OUTDOOR FINAL CONNECTIONS TO EQUIPMENT NOT TO EXCEED 36". 6.WHERE CONDUIT ENTERS OUTLET BOXES, FIXTURES OR CABINETS, FIRMLY FASTEN WITH STEEL SET SCREW, COMPRESSION CONNECTORS, OR DOUBLE LOCKNUTS FOR GRC. ALL CONNECTIONS SHALL HAVE BUSHINGS OR INSULATED THROAT CONNECTORS. FIRMLY FASTEN CONDUIT TO THE BUILDING CONSTRUCTION. RUN EXPOSED CONDUIT PARALLEL TO THE BUILDING LINES, SUPPORTED BY APPROPRIATE HANGERS (UNISTRUT, T & B OR APPLETON, OR EQUAL). 7.COVER METALLIC CONDUIT IN CONTACT WITH EARTH WITH POLYETHYLENE TAPED SPIRAL WRAPPED, 1/2 LAPPED TO PROVIDE 20 MIL. THICKNESS. TAPE SHALL BE SCOTCH NO. 50 TAPE. CONDUIT AND DUCTS NOT UNDER BUILDINGS AND FEEDER DUCTS SHALL BE INSTALLED PER N.E.C. 300-5. MAKE JOINTS WITH COMPOUND TO BE WATERTIGHT. 8.FITTINGS AND CONDUIT BODIES SHALL BE STEEL. NO DIECAST FITTINGS. 9.CONDUIT SIZES SHALL BE AS REQUIRED BY CODE AND AS INDICATED OR SPECIFIED. 10.ALL EMPTY CONDUIT SYSTEMS SHALL HAVE A NYLON PULL STRING TO FACILITATE INSTALLATION OF FUTURE WIRE. WHERE MORE THAN ONE CONDUIT TERMINATES IN A JUNCTION BOX, THE CONTRACTOR SHALL IDENTIFY EACH CONDUIT AND JUNCTION BOX IN A MANNER ALLOWING IDENTIFICATION AFTER ALL WALL FINISHES HAVE BEEN APPLIED. 11.SCHEDULE 40 PVC CONDUIT SHALL BE PERMITTED UNDERGROUND WITH PROPER FITTINGS, ALL UL APPROVED AND CEMENTED JOINTS. PENETRATIONS THROUGH FLOOR SLABS AND BENDS GREATER THAN 22°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Ø PANELS. SNAP IN BREAKERS ARE NOT ALLOWED UNLESS APPROVED BY ENGINEER. MANUFACTURERS SHALL BE SQUARE D (OR AS APPROVED BY ENGINEER AND STARBUCKS MANAGER) WITH VOLTAGE, SIZES, AND RATINGS AS INDICATED ON DRAWINGS. 2.THE CIRCUIT BREAKERS SHALL BE OPERABLE IN ANY POSITION AND BE REMOVABLE FROM THE FRONT OF THE PANEL BOARD WITHOUT DISTURBING THE ADJACENT UNITS. BRANCH BREAKERS SHALL BE OF SUCH DESIGN THAT COMBINATION OF SINGLE-POLE, DOUBLE-POLE, AND THREE-POLE BREAKERS CAN BE ASSEMBLED ON THE SAME PANEL. EACH BRANCH CIRCUIT SHALL BE CLEARLY NUMBERED. BRANCH AND MAIN TERMINALS SHALL BE OF THE SOLDERLESS TYPE. HANDLE TIES TO FORM MULTI-POLE BREAKERS NOT ACCEPTABLE. 3.PROVIDE AND UPDATE A TYPEWRITTEN CIRCUIT INDEX BEHIND CLEAR PLASTIC COVER ON INSIDE OF DOOR. INFORMATION SHALL INCLUDE ROOM AND TYPE LOAD SERVED. ALL CIRCUIT BREAKERS SHALL BE IDENTIFIED, INCLUDING SPARES. INDEX CARD FRAME SHALL BE METAL, SECURED TO DOOR. INDEX SHALL REFLECT AS-BUILT FINAL CONDITIONS. 4.ALL EQUIPMENT ELECTRICAL TERMINATIONS TO UNDERGO A TORQUE TEST. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MANUFACTURER'S RECOMMENDED TORQUE DOCUMENTATION AND TOOLS TO PERFORM TORQUE TEST. E. PANEL BOARDS 1.CONDUCTOR SIZES SHOWN ON THE DRAWINGS ARE BASED ON COPPER WIRE. UNLESS OTHERWISE SPECIFIED, ALL WIRE SHALL BE TYPE XHHW FOR FEEDERS OR BRANCH CIRCUITS LARGER THAN 4 AWG, TYPE THHN/THWN INSULATION FOR FEEDERS AND BRANCH CIRCUITS 4 AWG AND SMALLER. ALL BRANCH CIRCUIT WIRING SHALL BE COPPER. THE WIRES SHALL BE MARKED WITH COLOR TO SIMPLIFY CIRCUIT IDENTIFICATION. UNLESS OTHERWISE REQUIRED BY LOCAL ORDINANCES GROUND WIRES SHALL BE GREEN, NEUTRAL WIRES SHALL BE 120V- WHITE, 277V- GRAY, AND LIVE WIRES 208Y/120V AND 120/240 SHALL BE BLACK (PHASE A), RED (PHASE B), AND BLUE (PHASE C). FOR 480Y/277V CIRCUITS, THE COLOR CODE SHALL BE BROWN (PHASE A), ORANGE (PHASE B), AND YELLOW (PHASE C). THE WIRE SHALL BE 12 AWG UNLESS OTHERWISE INDICATED. CIRCUIT SHALL BE LABELED IN EACH J-BOX. 2.USE OF ALUMINUM WIRE IS NOT PERMITTED. 3.NO WIRE SHALL BE INSTALLED IN THE CONDUIT SYSTEM UNTIL THE CONDUIT SYSTEM IS COMPLETE. USE MINERALAC NO. 100 OR EQUIVALENT AS A LUBRICANT TO FACILITATE THE INSTALLATION OF THE CONDUCTORS IN THE CONDUIT SYSTEM. 4.SPLICES IN EXTERIOR PULL BOXES AND MANHOLES SHALL BE WEATHERPROOF USING "SCOTCHCAST" SPLICE KIT OR APPROVED EQUAL. SEAL ENDS OF CONDUITS AND DUCTS WITH "DUCTSEAL" OR APPROVED EQUAL. 5.PROVIDE SOLID CONDUCTOR FOR 12 AWG AND SMALLER. F. WIRE 1.WALL SWITCHES SHALL BE SPECIFICATION GRADE AC SILENT TYPE SWITCHES, 20A, 120/277 VOLT. 2.RECEPTACLES SHALL BE SPECIFICATION GRADE, DUPLEX TYPE, NEMA 5-20R, 20 AMPERE, 120 VOLT GROUNDED TYPE. SPECIAL APPLICATION RECEPTACLES SHALL BE INDICATED ON PLANS. MOUNT WITH THE GROUND DOWN. 3.DEVICE PLATES SHALL BE EQUAL TO SIERRA SMOOTH-LINE PLASTIC WALL PLATES. COLOR SHALL BE WHITE, UNLESS OTHERWISE NOTED. 4.RECEPTACLES IN OUTDOOR AND WET LOCATIONS SHALL BE INSTALLED WITH A HINGED OUTLET COVER/ENCLOSURE CLEARLY MARKED AND U.L. LISTED SUITABLE FOR WET LOCATIONS WHILE IN USE, EQUAL TO TAYMAC SPECIFICATION GRADE. G. WIRING DEVICES 1.REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT LOCATION OF ALL CEILING MOUNTED LIGHTING FIXTURES. ARCHITECTURAL DRAWINGS SHALL GOVERN IN CASE OF CONFLICT WITH THESE DRAWINGS. 2.PROVIDE ALL LIGHTING FIXTURES, WIRED AND CONNECTED. THE DRAWINGS INDICATE THE FIXTURES FOR EACH LOCATION. PROVIDE LAMPS FOR ALL FIXTURES. VERIFY CEILING CONSTRUCTION BEFORE ORDERING RECESSED UNITS. PROVIDE PLASTER FRAMES AND HANGERS AS REQUIRED. CEILING CONSTRUCTION, ARCHITECTURAL ACCESSORIES, VOLTAGE, AND BALLASTS TO MEET THE EXISTING CONDITION. H. LIGHTING FIXTURES 1.GROUNDING SHALL COMPLY WITH REQUIREMENTS OF ARTICLE 250. ALL EXPOSED NONCURRENT CARRYING METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC RACEWAY SYSTEMS, METALLIC CABLE ARMOR, GROUNDING CONDUCTOR OF NONMETALLIC SHEATHED CABLES, GROUNDING CONDUCTOR IN NONMETALLIC RACEWAYS, AND GROUNDED CONDUCTORS OF THE WIRING SYSTEM SHALL BE GROUNDED. 2.WHEN INDICATED ON THE DRAWINGS, EQUIPMENT GROUNDING CONDUCTORS SHALL BE EXTENDED FROM THE GROUND BUS IN THE DISTRIBUTION EQUIPMENT TO THE RECEPTACLE, FIXTURE OR DEVICE LUGS WHERE THEY ARE PROVIDED. WHERE LUGS ARE NOT PROVIDED, EQUIPMENT GROUNDING CONDUCTORS SHALL BE CONNECTED TO EQUIPMENT ENCLOSURES. THE CONNECTIONS SHALL BE ARRANGED SUCH THAT REMOVAL OF THE RECEPTACLE, EQUIPMENT GROUND CONDUCTORS, OR GROUND JUMPERS FROM GROUND BUSING SHALL NOT AFFECT THE GROUND SYSTEM. 3.RACEWAYS MAY NOT BE USED AS A GROUNDING CONDUCTOR FOR POWER AND LIGHTING CIRCUITS. ALL CONDUIT SHALL HAVE SEPARATE CODE SIZED GREEN GROUND WIRE INSTALLED IN THE CONDUIT TO INSURE A CONTINUOUS GROUNDING PATH. J. SYSTEM GROUNDING 1.TELEPHONE SYSTEM IS ORDERED AND COORDINATED BY CONTRACTOR AS DIRECTED BY STARBUCKS. 2.TELEPHONE WALL OUTLETS SHALL BE PROVIDED AT DATA RACK, SAFE AND/OR AS REQUESTED BY STARBUCKS MANAGER. CONNECT OUTLETS TO TELEPHONE TERMINAL WITH SEPARATE 3/4" CONDUIT UNLESS OTHERWISE SHOWN ON DRAWINGS. PROVIDE A TERMINAL MOUNTING BOARD FOR THE INCOMING SERVICE CABLE. K. TELEPHONE SYSTEM 1.FURNISH AND INSTALL TIME SWITCHES, PHOTOCELLS, CONTACTORS AND FULL LIGHTING CONTROL SYSTEMS AS REQUIRED FOR LIGHTING CONTROLS INDICATED ON THE DRAWINGS AND ACCORDING TO APPROVED LOCAL ENERGY CODES. 2.TIME SWITCHES SHALL BE EQUAL TO PARAGON, GENERAL ELECTRIC, TORK, OR INTERMATIC AND SHALL HAVE SIZE AND NUMBER OF POLES AS REQUIRED. 3.PHOTOCELLS SHALL BE EQUAL TO TORK OR INTERMATIC WITH VOLTAGE AS INDICATED. L. LIGHTING CONTROL 1.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE ALL NECESSARY CORRECTIONS AT NO ADDITIONAL COST TO OWNER. 2.GUARANTEE ALL MATERIAL FURNISHED AND ALL WORKMANSHIP PERFORMED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF WORK. ANY DEFECTS DEVELOPING WITHIN THIS PERIOD, TRACEABLE TO MATERIAL FURNISHED AS A PART OF THIS SECTION OR WORKMANSHIP PERFORMED HEREUNDER, SHALL BE MADE GOOD AT NO EXPENSE TO THE OWNER. M. GUARANTEE 1.THE ITEMS SPECIFIED HEREIN AND ON DRAWINGS ARE USED AS A STANDARD OF QUALITY. ANY MATERIALS OF EQUAL QUALITY AND AESTHETIC VALUE WILL BE GIVEN CONSIDERATION AS A SUBSTITUTE FOR THE MATERIALS SPECIFIED. NO APPROVAL WILL BE GIVEN TO A SPECIFIC CATALOG NUMBER, MODEL, OR TYPE OF EQUIPMENT, PRIOR TO BIDDING. AFTER BIDDING, THE DECISION OF THE ARCHITECT AND/OR ENGINEER DETERMINING EQUAL MATERIALS WILL BE FINAL. 2.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW OF THE FOLLOWING EQUIPMENT: A.ELECTRICAL SWITCHGEAR: SWITCHBOARDS, WITH PANELS, MOTOR CONTROL CENTERS AND SAFETY DEVICES. B.OVERCURRENT DEVICES: CIRCUIT BREAKERS AND FUSES INCLUDING TIME/CURRENT TRIP CURVES. C.LIGHTING FIXTURES: INDOOR/OUTDOOR AS SPECIFIED, PHOTOMETRIC PERFORMANCE DATA AND LAMPS. D.DEVICES: SWITCHES, RECEPTACLES, MOTOR CONTROLLERS AND DEVICE PLATES. E.LIFE SAFTY/FIRE ALARM SYSTEM: CONTROL PANEL, ANNUNCIATOR PANEL, INITIATION AND NOTIFICATION DEVICES/APPLIANCES, SYSTEM WIRING REQUIREMENTS AND DIAGRAM, SYSTEM LOAD CALCS, STANDARD BATTERY CALCULATIONS, AND AUXILIARY POWER SUPPLY. 3.SUBMIT ITEMS AT ONE TIME IN A NEAT AND ORDERLY MANNER WITHIN 15 DAYS OF AWARD OF CONTRACT. PARTIAL SUBMITTALS WILL NOT BE ACCEPTABLE. O. SHOP DRAWINGS AND APPROVALS 1.THE ELECTRICAL CONTRACTOR SHALL MAINTAIN A SET OF DRAWINGS AT THE JOB SITE FOR THE EXCLUSIVE PURPOSE OF MAINTAINING A RECORD OF ALL WORK INSTALLED AND TO SHOW ANY DEVIATIONS FROM THE WORK INDICATED ON THE DRAWINGS. 2.AT THE COMPLETION OF THE PROJECT, ONE SET OF REPRODUCIBLE DRAWINGS, SHOWING ALL AS-BUILT CONDITIONS, SHALL BE DELIVERED TO THE OWNER FOR ACCEPTANCE PRIOR TO FINAL PAYMENT. 3.DRAWINGS SHALL INCLUDE ACCURATE CONDUIT AND DEVICE LOCATIONS DIMENSIONED FROM PERMANENT LANDMARKS SUCH AS BUILDING WALLS. P. RECORD AND AS-BUILT DRAWINGS 1.PROVIDE FLEXIBLE CONNECTIONS TO ALL HVAC EQUIPMENT, WATER HEATER, ETC ANY EQUIPMENT OVER 20 LB AND/OR MOUNTED ABOVE FINISHED FLOORS. 2.COORDINATE ELECTRICAL REQUIREMENTS FOR ALL PLUMBING AND MECHANICAL EQUIPMENT WITH FINAL CONTRACTOR SELECTION. THE CONTRACTOR SHALL SIZE DISCONNECTS BASED UPON CIRCUIT BREAKER RATINGS AND PROVIDE FUSING AS REQUIRED PER EQUIPMENT MANUFACTURER RECOMMENDATIONS AND U.L. LISTING REQUIREMENTS. Q. EQUIPMENT CONNECTIONS 1.WHERE MOTORS ARE INSTALLED IN SUSPENDED CEILINGS, CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH IN SUSPENDED CEILING WITHIN REACH FROM ACCESS POINT. 2.SIZING OF MOTOR-RELATED ELECTRICAL COMPONENTS, INCLUDING FEEDER AND/ OR BRANCH CIRCUITS (WIRE AND CONDUIT) AND OVERCURRENT PROTECTION (BREAKER AND/ OR FUSES) IS BASED ON RATINGS INDICATED IN THE CONTRACT DOCUMENTS AS WELL AS NEC APPROXIMATED LOADS FOR A GIVEN MOTOR HORSEPOWER, VOLTAGE AND PHASE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ACTUAL MOTOR AND APPLIANCE RATING AND LOADS. CONTRACTOR TO PROVIDE CORRECTLY SIZED MOTOR OVERLOAD ELECTRICAL COMPONENTS BASED ON NAMEPLATE RATING. REFLECT ALL CHANGES IN THE AS-BUILT DRAWINGS. 1.CONTRACTOR SHALL ENGAGE THE SERVICES FOR A STATE LICENSED FIRE ALARM MANUFACTURER/INSTALLER TO PREPARE ALL DESIGN DRAWINGS AND CALCULATIONS REQUIRED FOR SYSTEM APPROVAL BY THE AUTHORITY HAVING JURISDICTION. SUBMIT ALL PLANS AND PROVIDE ALL PERMITS REQUIRED FOR A COMPLETE AND OPERABLE APPROVED LIFE SAFETY SYSTEM. 2.FIRE ALARM DEVICE WIRING SHALL BE MINIMUM #14 AWG COPPER OR PER SYSTEM MANUFACTURER REQUIREMENTS. PROVIDE MINIMUM 3/4" SEPARATE RACEWAY SYSTEM OR AS REQUIRED FOR LIFE SAFETY SYSTEM WIRING CONFIGURATION. 3.UPON COMPLETION OF THE INSTALLATION OF LIFE SAFETY SYSTEM WIRING AND DEVICES, A PERFORMANCE TEST OF THE ENTIRE LIFE SAFETY SHALL BE PERFORMED TO THE SATISFACTION OF THE AUTHORITY HAVING JURISDICTION. S. FIRE SYSTEM 1.MUSIC, TELEVISION, VIDEO MOUNTING SYSTEMS ARE NOT SHOWN ON THESE DRAWINGS AND ARE PROVIDED BY CONTRACTOR THROUGH ARCHITECTS SCHEDULES/DETAILS. CONTRACTOR TO COORDINATE ALL ROUTING AND FINAL CONNECTIONS AS APPROVED BY STARBUCKS MAMAGER AS APPLICABLE SPECIFICALLY TO THIS STORE. T. LOW VOLTAGE SYSTEMS 1.PERFORM THE EXCAVATION, CUTTING, FITTING, REPAIRING, AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT OF THIS SECTION. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBERS SHALL BE DONE WITHOUT THE CONSENT OF THE ENGINEER. 2.FINISH ALL SURROUNDING WORK TO THE SATISFACTION OF THE ARCHITECT. I. EXCAVATION, CUTTING, AND FITTING SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-002 ELECTRICAL NOTES SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-003 ELECTRICAL ENERGY COMPLIANCE NEIGHBORING TENANTS 4,000 SF STARBUCKS 2,295 SF 9'-2" 7' - 1 1 3 / 4 " 15'-10 1/4" 25 ' - 1 1 " 6'-2 1/4" 1' - 4 1 / 4 " 8'-1 3 / 4 " 7'-6 1 / 4 " 1 6 ' - 7 1 / 2 " Scale: 1/16" = 1'-0"1 ELECTRICAL SITE PLAN POWER GENERAL NOTES A.REFER TO THIS SHEET FOR POWER, WIRING, DATA, ETC. INFORMATION REGARDING EXTERIOR SITE AND SIGNAGE EQUIPMENT ("Y" OR "S" LABELED). CIRCUIT NUMBERS SHOWN ON THIS DRAWINGS ARE FOR THE EQUIPMENT WHICH HAS POWER REQUIREMENTS. B.REFER TO PLUMBING PLANS FOR ADDITIONAL INFORMATION. THIS SHEET IS PROVIDED FOR REFERENCE ONLY AND TO SHOW LOCATIONS AND TYPES OF EXISTING ELECTRICAL SERVICES FOR THIS BUILDING. C.REFER ALSO TO ARCHITECTURAL SITE PLAN. D.CONDUIT ROUTING IS FOR REFERENCE ONLY, VERIFY LOCATION IN FIELD. E.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. SIGNAGE GENERAL NOTES (UNDER SEPARATE PERMIT) A.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. B.CONDUIT ROUTING IS FOR REFERENCE ONLY, VERIFY LOCATION IN FIELD. C.FOR SIGNAGE, THESE DRAWINGS ARE TO AID IN INSTALLATION OF CONDUIT AND PREP WORK ONLY. COORDINATE ALL WORK THROUGH SIGNAGE VENDOR. D.CONDUIT RUNS HAVE BEEN SPECIFIED ON THE SHELL DRAWINGS, COORDINATE WITH FINAL SIGNAGE VENDOR. THESE PLANS FOR FOR FINAL ELECTRICAL CONNECTION REQUIREMENTS. KEYED NOTES EXISTING ELECTRICAL DISCONNECT SWITCH, METER, AND CT CABINET. SEE SINGLE LINE DIAGRAM FOR ADDITIONAL INFORMATION. EXISTING UTILITY TRANSFORMER TO SERVE STARBUCKS. SEE SINGLE-LINE DIAGRAM FOR ADDITIONAL INFORMATION. NOT USED. MENUBOARD, PYLON SIGNAGE AND DRIVE THRU SIGNAGE: PROVIDE 120V POWER FEED IN EXISTING 1" CONDUIT FROM STARCKBUCKS PANEL INDICATED VIA TIMECLOCK CONTROLS. COORDINATE WIRE SIZE WITH VOLTAGE DROP PER ACTUAL ROUTING IN FIELD. PROVIDE MEANS OF DISCONNECT IF NOT PROVIDED WITH SIGNAGE. EXISTING 1" CONDUIT FOR VEHICLE DETECTION LOOP. SEE DT SENSOR LOOP DETAIL ON THIS SHEET. BUILDING MOUNTED SIGNAGE. EXISTING JUNCTION BOX PROVIDED WITH SHELL. PROVIDE 120V POWER FEED FROM STARCKBUCKS PANEL INDICATED VIA TIMECLOCK CONTROLS. COORDINATE WIRE SIZE WITH VOLTAGE DROP PER ACTUAL ROUTING IN FIELD. PROVIDE MEANS OF DISCONNECT IF NOT PROVIDED WITH SIGNAGE. 1 2 3 4 5 8'-10" 6'-8" PLAN VIEW 1'-6" STONE CURB 5'-0" A-A SECTION CUT 2" VEHICLE LOOP DETECTOR ASPHALT OR CONCRETE BY LL LOOP SUPPORT GRAVEL AND SAND SPEAKER POST FOOTING PER LL 1/2" PVC 2" LONG TUBING 90 DEGREE BELOW ELBOW FOR 1/2" PVC TUBING 1/2" PVC 3" LONG TUBING LEAD WIRE SLOT PREFAB IF ORDERED LOOP 1.5' WIDE BY 5' LONG COUPLING FOR 1/2" PVC TUBING Scale:NTS2DT SENSOR LOOP DETAIL LEGEND LOW VOLTAGE SIDE DOS CONTROL BOX (DCB) GRADE ORDER ZONE DETECTOR LOOP DTE POS WINDOW BOH SVC PANEL BUILDING INTERIOR KA N E X C A M P O W E R 3/ 4 " - L O O P 1" - L O O P , S P E A K E R , M I C 1" - K A N E X , C A M E R A , S P A R E 1" - D E D I C A T E D P O W E R DE D I C A T E D P O W E R D E D I C A T E D P O W E R 1/ 2 " - S P E A K E R CA M E R A C A M P O W E R , M I C DIGITAL ORDER SCREEN (DOS) LINE VOLTAGE SIDE RIGID CONDUIT FLEX CONDUIT DOS WHIP NOTES 1.GC TO INSTALL DCB 2.GC TO PROVIDE AND INSTALL DCB SUPPORT FRAME, CONCRETE FOOTING AND ALL NEW RIGID AND FLEXIBLE CONDUITS. 3.GC TO PROVIDE, INSTALL AND CONNECT ALL LINE VOLTAGE LINES. 4.GC TO CONNECT DEDICATED POWER WHIP BETWEEN DOS AND DCB. 5.STARBUCKS VENDOR TO CONNECT ALL LOW-VOLTAGE WHIPS AND CABLING BETWEEN DOS AND DCB. 6.POWER TO DOS MAY NOT BE ON EMS OR LIGHTING CONTROL. ·EMBED UNISTRUT POSTS WHERE APPLICABLE ·ROUTE RIGID CONDUIT THRU FOOTING WHERE APPLICABLE CONCRETE FOOTING Scale:NTS3DCB CONNECTIVITY PLANN 6 S 23747 2 5 Y 225404 Y 225464Y225424 P1A-16 (TIE) 6S22606 6S22606 5 6 P1A-1 (TIE) S 22606 S 23074 S 237336 P1A-3 (TIE) S 23105 1 P1A-16 (TIE) P1A-16 (TIE) P1A-1 (TIE) P1A-1 (TIE) 6 P1A-3 (TIE) 6 P1A-5 (TIE) 6 P1A-5 (TIE) P1A-37 S A (9) SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-006 SITE ELECTRICAL PLAN CAFE ENGINE WORKROOM RESTROOM VEST.RESTROOM 1 RESTROOM 2 DRIVE-THRU E 16239 29 P1B-31,33 20 6 SEE POS DETAILS ON SHEET E-502 3 3 Scale: 1/4" = 1'-0"1 ELECTRICAL POWER PLAN A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM. B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE VERIFIED WITH OWNER PRIOR TO ROUGH-IN. PROVIDE G.F.C.I. TYPE RECEPTACLE WITHIN 6 FEET OF ANY SINK. D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. J.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE LOCATED: - NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND - NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. K.CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE. L.ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48" ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX. K.EACH AND EVERY 120VAC., 15 AND 20 AMP, 1 PH., RECEPTACLE IN KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL BE GFCI TYPE PROTECTION. 210.8(B). ANY RECEPTACLE INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE. GFCI DEVICES MUST BE REMOTELY ACCESSIBLE. GENERAL NOTES E 23424 N 30 30 KEYED NOTES 1.ESPRESSO MACHINE: PROVIDE RECEPTACLE MOUNTED AT 30" AFF; FIELD VERIFY NEMA CONFIGURATION REQUIRED. 2.ICE MACHINE: RECEPTACLES AND CONNECTIONS PER 'E' SCHEDULE ON THIS SHEET. CONFIRM ELECTRICAL REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH-IN. 3.FLOOR POWER/DATA: SEE PENETRATION PLAN FOR EXACT DIMENSIONING AND LOCATION. 4.CUP LABELER OR MOBILE ORDER PRINTER: PROVIDE RECEPTACLE AND BACKBOX FOR DATA OUTLET AT 26" AFF. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. 5.SIGNAGE OUTLET, PROVIDE W/IN 18" OF THE TOP OF WINDOW. 6.POS: FURNISH AND INSTALL DOUBLE-DUPLEX MOUNTED @ 18" AFF PROVIDE DEDICATED GROUND WIRE BACK TO SERVING PANEL. INSTALL (1) J-BOX FOR DATA OUTLET AND (1) J-BOX FOR PHONE OUTLET AT 18" AFF. SEE DETAILS ON E-501/E-502. 7.GRINDER AND SCALE: PROVIDE RECEPTACLE MOUNTED BELOW COUNTER. 8.ALL BACK BAR AND FRONT BAR J-BOXES AND OUTLETS SHALL BE SURFACE MOUNTED. PROVIDE CONDUITS AS NEEDED AND (1) ADDITIONAL SPARE CONDUIT BETWEEN ALL J-BOXES FOR FUTURE ELECTRICAL REQUIREMENTS. ALL J-BOXES SHALL BE POSITIONED TO AVOID OBSTRUCTION OF ANY EQUIPMENT SUCH AS REFRIGERATORS AND DISHWASHERS. 9.OVEN COMBI: CONFIRM NEMA CONFIGURATION AND MOUNTING HEIGHT. 10.BLENDER: PROVIDE RECEPTACLE MOUNTED BELOW COUNTER. 11.RECEPTACLE FOR FUTURE USE. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH OWNER'S REPRESENTATIVE. 12.DATA OUTLET FOR FUTURE USE: PROVIDE BACKBOX FOR DATA OUTLET MOUNTED AT 26" AFF. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. 13.BLENDER PITCHER RINSER: PROVIDE RECEPTACLE MOUNTED AT 26" AFF. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. 14.UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE MOUNTED BELOW COUNTER. 15.COORDINATE EXACT LOCATION AND MOUNTING HEIGHT(S) OF ALL CONVENIENCE RECEPTACLES WITH OWNER'S REPRESENTATIVE. 16.CLOVER BREWER: PROVIDE RECEPTACLE MOUNTED AT 48" AFF; VERIFY NEMA CONFIGURATION REQUIRED. 17.WARMING OVEN: PROVIDE NEMA 6-30R RECEPTACLE MOUNTED AT 26" AFF. 18.NITRO EQUIPMENT: PROVIDE RECEPTACLE MOUNTED BELOW COUNTER. 19.COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS FOR BANQUETTE SEATING WITH OWNER'S REPRESENTATIVE. 20.PROVIDE 4-SQUARE J-BOX FOR "STROBE LOCATION J-BOX". SEE DETAIL ON E-501. 21.PROVIDE NECESSARY CONDUIT FOR POWER AND DATA OUTLETS TO MANAGER'S DESK LOCATION. SEE REQUIRED POWER AND DATA OUTLETS ON DETAIL ON E-501/E-502. 22.PROVIDE RECEPTACLE AND DATA OUTLET CENTERED HORIZONTALLY FOR FUTURE DIGITAL MENU BOARD. PROVIDE BACKBOX FOR DATA OUTLET. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. SEE ARCHITECTURAL ELEVATIONS FOR MENU BOARD LOCATIONS. 23.RECIRC PUMP - PROVIDE MOTOR RATED DISCONNECT SWITCH AND CONTROL VIA TIMECLOCK. 24.PROVIDE RECEPTACLE ABOVE REACH-IN REFRIGERATOR/FREEZER. FIELD VERIFY LOCATION. 25.PROVIDE OUTLETS AND COMMUNICATIONS FOR DRIVE THRU AND CASH REGISTER POS EQUIPMENT. SEE DATA DEVICE SCHEDULE ("A" LABELED) ON THIS SHEET. COORDINATE WITH ARCHITECTURAL AND STARBUCKS. 26.POS PRINTER: PROVIDE DATA BACK-BOX. ROUTE 3/4" CONDUIT FROM BACK-BOX TO DATA RACK NEAR MANAGER'S WORKSTATION. 27.DRIVE-THRU (DTP) OUTLETS. REFER TO DRAWING E-501/E-502 FOR MORE INFORMATION AND CIRCUITING. 28.MANAGER'S DESK/IT RACK OUTLETS. REFER TO DRAWING E-501/E-502 FOR MORE INFORMATION AND CIRCUITING. 29.PASTRY CASE: PROVIDE RECEPTACLE; FIELD VERIFY NEMA CONFIGURATION AND MOUNTING HEIGHT REQUIRED PRIOR TO ROUGH-IN. 30.LOCATION OF EXISTING HVAC EQUIPMENT (PROVIDED IN SHELL). DASHED LINES INDICATES ON ROOF. MAINTAIN EXISTING CIRCUIT. 31.LOCATION OF HVAC EQUIPMENT SEE MECHANICAL FEEDER/CONNECTION SCHEDULE ON THIS SHEET. DASHED LINES INDICATES ON ROOF. 32.LED LIGHT STRIP: REFER TO SHEET "E-102" FOR LIGHTING INFO AND LIGHTING ITEM NUMBER. SPECIFIC LED STRIP CONNECTION SHOWN HERE FOR CLARITY. REFER TO ARCHITECTURAL DETAILS FOR ADDITIONAL MOUNTING INFORMATION. GFCI P1A-12 P1B-28,30 31 T/USB T/USB 19 (TYPICAL OF 6) P1B-13 (TIE) T/USB T/USB T/USB T/USB 15USB 15USB 15USB E 1026714 P1B-1 24 E 11083 24 E 11083 P1B-3 24 E 13682 P 22642 P1B-8 P 22642 P1B-10 P 22642 P1B-12 E 12618 14 P1A-15 (TIE) P1A-15 (TIE) E 12618 14 18 E 21679 E 20010 P1B-9 18 E 10808 E 22885 7 16 11 12 12 P1B-32,34 P1B-2 A 22970 A 10076 A 10022 A 10007 A 10005 A 10002 21 26 P1A-15 (TIE)E 10267 27 14 25 GFCI 15 P1A-15 (TIE) E 12508 10 P1A-14P1A-17E1026714 E 10267 14 E 15186 P1A-39,41 E 23421 E 23182 2 P1B-6 E 1756413 P1B-4 E 197421 P1B-36,38 P1B-40,42 E 19742 1 E 20032(2) P1B-35,37 17 12 P1B-39,41(3)E 23419 P1B-7 E 23442 9 P1A-29,31,33 E 23444 P1A-28,30 P 12501 P 13082 P1B-17 23SEE DETAIL 1/P501 FOR REC LOCATIONS P1B-43 P1B-15 P1A-13 E 1026714 E 1026714 E 10267 14 A 10075 4 12 12 P1A-13 P1A-13 P1A-13 P1A-13 P1A-32,34,36 P 11109 P1A-15 (TIE) EXISTING PANEL 'P1A' EXISTING PANEL 'P1B' P1A-12 P TK0045 A 14678 A 14677 A 22725 A 10012 A 10014A22726 P1B-14 30 A 22970 P1B-5 P1B-5 P1B-23 P1B-11 (TIE) P1B-11 (TIE) P1B-11 (TIE) P1B-13 (TIE) P1B-13 (TIE) P1B-25,27,29 P1B-22,24,26 P1B-16,18,20 P1B-21 5 5 5 5 31 31 8 22 28 208V 1PH NOTE: 1.SEE EQUIPMENT SCHEDULE "E" ON THIS SHEET, FOR ADDITIONAL INFORMATION. 2.DISCONNECT SWITCH AND CONVENIENCE RECEPTACLE IS PROVIDED WITH UNIT. 3.CIRCUIT DUCT DETECTOR TO P1A- AND LOCATE REMOTE TEST STATIONS PER OWNER AND AHJ. PROVIDE HORN/STROBE AS REQUIRED BY AHJ AND LOCATED PER OWNER/AHJ. 4.CONFIRM ALL REQUIREMENTS PRIOR TO ROUGH-IN. 5.CONTROL VIA TIMECLOCK FOR OCCUPIED HOURS. MECHANICAL FEEDER/CONNECTION SCHEDULE ITEM VOLTAGE M.C.A. FEEDERS TYPE OF CONN BRANCH BREAKER/ SWITCHWIRECOND REMARKS 200A-2P142EXISTING RTU-1 120V 1PH 15A-1P-EXISTING EF-1 NOTES 5 NOTES 2,3EXISTING 208V 1PH 150A-2P116EXISTING RTU-2 NOTES 2,3 208V 1PH 3#6THHN 1#10 G 1"THRU 60A DS 45A-2P27.1CU-1 NOTES 1,4 120V 1PH 15A-1P-15A DISCONNECT SWITCHAC-1 2#12THHN 1#12 G 1/2" 208V 3PH 35A-3P26.5 35A DISCONNECT SWITCHAC-2 3#8THHN 1#10 G 3/4" 208V 3PH 3#8THHN 1#10 G 3/4"THRU 60A DS 40A-3P30.8AC-3 CKT-1 NOTES 1,4 208V 3PH 3#10THHN 1#10 G 3/4"THRU 30A DS 30A-3P22.2AC-3 CKT-2 NOTES 1,4 NOTES 1,4 NOTES 1,4 P1B-44 (TIE) EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 3111 P 23355 P1B-19 P1A-44 P TK0045 P1A-15 P1A-13 P1B-44 (TIE) A 100754 A 10075 4 A 100754 E 12508 E 23421 P1B-45 10 (Dimmer "d") L 22440 32 (≈28'-6") P1A-18 (TIE) 28 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-101 POWER PLAN Scale: 1/4" = 1'-0"1 ELECTRICAL LIGHTING PLAN KEYED NOTES 1.SWITCHBANK. REFER TO SWITCH BANK DETAIL 2 ON THIS SHEET AND LIGHTING CONTROL DIAGRAM ON SHEET E-601. 2.EMERGENCY/EXIT FIXTURE. GC TO PERFORM TEST TO ENSURE EMERGENCY BATTERY UNIT WILL PROVIDE BACKUP POWER FOR MINIMUM 90 MINUTES. 3.NOT USED. 4.NOT USED. 5.NOT USED. 6.WALL MOUNTED MOTION SENSING CONTROL (LEVITON IPS02 1LW) SHALL CONTROL LIGHTING IN THIS ROOM. SET FOR 5 MINUTE DELAY. 7.LED LIGHT STRIP: REFER TO ARCHITECTURAL DETAILS FOR ADDITIONAL MOUNTING INFORMATION. 8.FIXTURE PROVIDED WITH EMERGENCY BATTERY BACK UP, SEE LIGHTING FIXTURES SCHEDULE 'L' FOR MORE INFORMATION. GENERAL NOTES A.REFER TO THIS SHEET FOR LIGHTING FIXTURE SCHEDULE AND E600 FOR PANEL SCHEDULES. REFER TO LUTRON DRAWINGS IN THIS PACKAGE FOR LIGHTING CONTROLS. B.PROVIDE A DISCONNECTING MEANS FOR EACH MULTI-WIRE BRANCH CIRCUIT IN ACCORDANCE WITH NEC 410.130(G)(1) THROUGH (3). DISCONNECTING MEANS SHALL BE LOCATED AT POINT WHERE CIRCUIT ORIGINATES AND SHALL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS. C.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND ELEVATION OF ALL LIGHTING FIXTURES. D.THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING FIXTURES AND MANUFACTURERS' CATALOG NUMBERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL REFLECTED CEILING PLAN AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY TRIMS AND MOUNTING HARDWARE. E.COORDINATE EXACT LIGHTING FIXTURE LOCATIONS WITH ELECTRICAL, MECHANICAL, PLUMBING EQUIPMENT, INCLUDING CONDUIT, PIPING, DUCTING, ETC. PRIOR TO ROUGH-IN. F.ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED STRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED ISSUE OF THE CALIFORNIA BUILDING CODE, AS WELL AS ANY LOCAL CODES. G.ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL. H.ALL FLUORESCENT DIMMING ZONES/CHANNELS SHALL BE PROVIDED WITH 3 LINE VOLTAGE CONDUCTORS (NEUTRAL, DIMMED HOT, SWITCHED HOT) OR 2 LINE VOLTAGE CONDUCTORS/2 CONTROL CONDUCTORS AS REQUIRED BY THE CONTROL/BALLAST TYPE. I.'EM' EMERGENCY EGRESS LIGHT TO BE PROVIDED WITH 90 MINUTE BATTERY BACKUP (EITHER NEW WITH FIXTURE OR RETROFITTED ONTO EXISTING). INTENT IS TO ENSURE 1.0 FOOT CANDLES AT WALKING SURFACE. GC SHALL CONFIRM CONFORMANCE THROUGH METERING. J.ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD OF THE LOCAL AREA CIRCUIT. K.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ORDERING EXIT SIGNS. A JUNCTION BOX MUST BE PROVIDED WITH ALL EXIT LIGHTS CONNECTED TO MORE THAN ONE SET OF CONDUCTORS UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN APPROVED OUTLET BOX FOR THROUGH WIRING. L.ALL LOW VOLTAGE LIGHTING SYSTEMS SHALL COMPLY WITH 2016 CEC ART. 411 AND SHALL BE LISTED PER 411.3 OR LOCAL CODES HAVING JURISDICTION. M.ALL ELECTRICAL EQUIPMENT LOCATED OUTSIDE SHALL BE WEATHERPROOF. N.ALL LOW VOLTAGE WIRING NOT RUN IN CONDUIT SHALL BE PLENUM RATED. O.MOUNT ALL SWITCHES, CONTROLS, RECEPTACLES BETWEEN 15"- 48" AFF. N L 21772(2) L 21772(2) L 21772(2) EM 8 L 15057(7)EM 8 L 15057(2) L 21772 (4) L 21772 (6) L 20831(3) L 21772 (37) L 21772(24) L X2851 L X2851 (Dimmer "d")L 22216 7 (≈20'-9") (Dimmer "d")L 22216 7 (≈28') OS 6 OS 6 P1A-18 (TIE) EM 8 (Dimmer "e") EM 8 EM 8 EM 8 EM 8 EM 8 EM 8 EM 8 EM 8 (Dimmer "a") P1A-18 (TIE) (Dimmer "b") (Dimmer "h") (Dimmer "f") (Switch "g") 1 P1A-18 (TIE) P1A-18 (TIE) P1A-18 (TIE)P1A-18 (TIE) P1A-18 (TIE) P1A-18 (TIE) P1A-18 (TIE) P1A-18 (TIE) (Dimmer "c") P1A-18 (TIE) EXISTING PANEL 'P1A' EXISTING PANEL 'P1B' (Dimmer "d")L 22440 7 (≈6'-10")P1A-18 (TIE) L 19049 L 19049 2 2 1 A 10015 4 A 10015 4 Scale:NONE2SWITCH BANK DETAIL DS "a" DS "b" DS "c" S "e" DS = DIMMER SWITCH S = NON DIMMING SWITCH LEGEND: DIMMER SWITCH CONTROL: DS "b" = Cafe Lighting DS "d" = Cafe/Engine Strip Lighting DS "a" = Engine Lighting DS "e" = Restroom Vestibule Lighting DS "f" = Engine Pendant DS "d" DS "c" = Cafe Accent Lighting DS "f" S "g" = Workroom S "g" S "h" DS "h" = Cafe Sconce Lighting SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-102 LIGHTING PLAN CAFE ENGINE WORKROOM RESTROOM VEST.RESTROOM 1 RESTROOM 2 PATIO DRIVE-THRU Scale: 1/4" = 1'-0"1 ELECTRICAL LOW VOLTAGE PLAN N A.CONDUITS SHALL, (a) CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98FT), AND, (b) CONTAIN MORE THAN (2) 90 DEGREE BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A PULLBOX. CONDUITS IN PLACE OF PULL BOXES IS UNACCEPTABLE. B.CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 20 LB. C.CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES OF THE INTERNAL CONDUIT DIAMETER FOR CONDUITS 2" IN DIAMETER OR LESS, AND (b) 10 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS MORE THAN 2" IN DIAMETER. D.TERMINATE CONDUITS THAT PROTRUDE THROUGH STRUCTURAL FLOORS 3" ABOVE THE FLOOR SURFACE. E.INSTALL BUSHINGS AND BELL ENDS AS REQUIRED ON ALL CONDUITS. F.FLEX CONDUIT IS GENERALLY UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC JOINTS AND AS APPROVED IN WRITING BY THE ENGINEER. G.ALL SUB SLAB CONDUITS SHALL BE INSTALLED IN A MATTER THAT PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE RAIN WATER OR CONSTRUCTION WATER IS PREVENTED FROM ENTERING AND/OR REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT OF COMMUNICATION CABLES. H.ALL PULL BOXES SHALL BE SIZED AND INSTALLED PER ANSI/TIA/EIB-569A. PULL BOXES FOR UNDER FLOOR CONDUIT RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULL BOXES FOR OVERHEAD CONDUIT RUNS SHALL BE LOCATED ABOVE ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING SPACE. I.CONDUIT(S) SHALL EXIT A PULL BOX ON THE WALL OPPOSITE THE WALL ENTERED. J.IF FIRE ALARM DEVICES ARE INDICATED ON PLANS, THEN THE ELECTRICAL CONTRACTOR SHALL SUBMIT FIRE ALARM PLANS AND OBTAIN APPROVAL PRIOR TO INSTALLATION. GENERAL NOTES 1.SAFE: PROVIDE RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR SECURITY ALARM JACK AND ROUTE CONDUIT BACK TO SECURITY PANEL J-BOX. REFER TO MANAGER'S DESK DETAIL AND POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 2.PROVIDE RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT TO RECEPTACLE, PROVIDE J-BOXES FOR TELEPHONE AND DATA. ROUTE CONDUIT(S) BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 3.STUB UP POWER, DATA PHONE AND/OR SECURITY CONDUITS 6" AFF TO SERVE NEARBY DEVICES IN THIS LOCATION. ROUTE POWER CONDUCTORS IN FLEXIBLE METAL CONDUIT CONCEALED OR TIGHT-TO-WALL FROM RECEPTACLES TO NEARBY RIGID STUB UP AND BACK TO SERVING POWER PANEL. ROUTE DATA, PHONE AND SAFE CONDUITS UNDER FLOOR BACK TO DATA RACK NEAR MANAGER WORKSTATION. PROVIDE AN END-TO-END PULL STRING IN ALL DATA PHONE AND SAFE CONDUITS. LABEL EACH END OF PULL STRING WITH CONDUIT SYSTEM ("POS", "SECURITY", ETC..) AND DESTINATION ("DRIVE-THRU", "FRONT BAR", ETC..). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED CONDUIT ENDS. REFER TO ARCHITECTURAL PENETRATION PLAN FOR ADDITIONAL INFORMATION. 4.CUP LABELER AND/OR MOBILE ORDER PRINTER: PROVIDE RECEPTACLE AND ADJACENT DATA BACKBOX AT SAME MOUNTING HEIGHT - COORDINATE LOCATION AND MOUNTING HEIGHT WITH OWNER'S REPRESENTATIVE PRIOR TO ROUGH IN. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORKSTATION. 5.DT POS AND EXPEDITER TILL MONITOR: PROVIDE DOUBLE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 6.DT EXPEDITER MONITOR: PROVIDE DOUBLE DUPLEX RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 7.DT TIMER CONTROL UNIT AND MONITOR: PROVIDE DOUBLE DUPLEX RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 8.DT TIMER SIGNAL PROCESSOR: PROVIDE DUPLEX RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 9.WIRELESS HEADSET BASE STATION: PROVIDE DUPLEX RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 10.TELEPHONE AND DATA OUTLETS FOR MANAGER'S DESK: REFER TO MANAGER'S DESK DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION. 11.CARBON MONOXIDE DETECTOR AND THERMOSTATS FOR ROOF TOP HVAC UNITS: COORDINATE INSTALLATION AND CONNECTION WITH MECHANICAL CONTRACTOR. COORDINATE LOCATION(S) WITH OWNER'S REPRESENTATIVE. VERIFY LOCATIONS/CONNECTIONS PRIOR TO INSTALLATION. 12.DATA OUTLET FOR FUTURE USE: PROVIDE BACKBOX MOUNTED AT 26" ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. 13.PROVIDE RECEPTACLE AND DATA OUTLET CENTERED HORIZONTALLY BEHIND MENU BOARD FOR FUTURE DIGITAL MENU BOARD. PROVIDE BACKBOX FOR DATA OUTLET. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. SEE INTERIOR ELEVATIONS FOR MENU BOARD LOCATIONS. 14.NOT USED. 15.NOT USED. 16.RECESSED SPEAKER. CONFIRM FINISH. 17.AMPLIFIER: LOCATE ON SHELVING ABOVE MANAGER'S WORKSTATION (SEE DETAIL ON E-501/E-502). 18.CONDUIT PATHWAY ABOVE CEILING FOR FUTURE ANTENNA COAXIAL MINIMUM 1-14" CONDUIT WITH THICK END-TO-END PULL STRING. MINIMUM 8-1/2" RADIUS BENDS, MAXIMUM 100'-0" RUN, NO CONSECUTIVE 90-DEGREE BENDS. TERMINATE AT J-BOX WITH COVER PLATE AT CEILING/WALL WITHIN 2'-0" OF BUMP BASE STATION AND ABOVE BOH CEILING ADJACENT FUTURE PENETRATION ZONE. 19.THIS CONFIGURATION IS TYPICAL OF DRIVE-THRU DATA REQUIREMENTS AND EQUIPMENT. COORDINATE EXACT REQUIREMENTS OF RELOCATED EQUIPMENT WITH OWNER'S REPRESENTATIVE. 20.THIS CONFIGURATION IS TYPICAL OF POS STATION DATA REQUIREMENTS AND EQUIPMENT. COORDINATE EXACT REQUIREMENTS OF RELOCATED EQUIPMENT WITH OWNER'S REPRESENTATIVE. KEYED NOTES 17 A 10076 A 10002 A 10005 A 10007 A 10022 11 10 10 A 14678 A 14677 A 22725 A 10012 A 12336A22726 5 9678 19 4 2 2 1 20 2 13 A 22970(3) A 10015 A 10015 12 A 10075 A 10075 4 4 A 100754 12 12 12 12 12 EXISTING PANEL 'P1A' EXISTING PANEL 'P1B' 13 A 22970 1616 12 A 10075 4 3 3 12 12 18 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-103 LOW VOLTAGE DESIGN PLAN . 15 0 M M . 15 0 M M 6" 6" 9-1/2" (240MM) Scale: 3/4" = 1'-0"2 WATER FILLING STATION - ELECTRICAL Scale: 3/4" = 1'-0"3 ICE MACHINE - ELECTRICAL Scale: 3/4" = 1'-0"4 REFRIGERATOR/FREEZER - ELECTRICAL 2 2 2 SECURITY CONTROL ALARM PANEL WIRELESS MODEM AT 84" (2130MM) A.F.F. STARBUCKS VENDOR TO DETERMINE OPTIMAL DEVICE LOCATION EMS DATA CONCENTRATOR. ALLOW 2" (50 MM) IN. CLEAR ABOVE POWER & DATA RECEPTACLES AT 60" (1525MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'C' ABOVE FOR DESCRIPTION. HOME PHONE CONNECT (HPC) CORDLESS 1 LINE PHONE OFFICE PC IPOD TOUCH CHARGING CRADLE POWER, TELEPHONE & DATA RECEPTACLES AT 12" (305MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'A' ABOVE FOR DESCRIPTION DEMARC, IF REQUIRED POWER AND DATA RECEPTACLES AT 80" (2030MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'B' ABOVE FOR DESCRIPTION WALL MOUNTED SHELVING UNIT ATTACHED TO BACKER BOARD MUSIC SYSTEM PLAYER AND AMPLIFIER (FURNISHED BY OWNER, INSTALLED WITH SPEAKER SYSTEM BY GC) ON 14" DEEP (355MM) SHELF ONLY (MIN.) (NOT IN EQUIP. RACK). ELEVATION VIEW 1 UPS IPS EQUIPMENT ROUTER EQUIPMENT RACK SCHEDULE NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE.SECURITY RECORDER (NVR) SECURITY KEYBOARD NETWORK SWITCH PATCH PANEL PRODUCTION CONTROLLER DEVICES BOH CEILING. REFER TO REFLECTED CEILING PLAN(S) FOR ACTUAL HEIGHT. PRINTER 78" W X 96" H (1980MM W X 2440MM H) MIN. 3/4" FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE & FINISH AS SCHEDULED. SECURITY MONITOR MOUNTED ON MONITOR ARM (ATTACHED TO BACKER BOARD). ROLLING CART 4' - 0 " ( 1 2 2 0 M M ) A. F . F . EQUIPMENT RACK (SIDE VIEW). SEE ELEVATION 2 FOR MORE INFORMATION DESK SHELVING ABOVE POWER & DATA RECEPTACLES (IN WALL, ABOVE SHELVES) (1) QUAD RECEPTACLE FOR: EMS DATA CONCENTRATOR (1) DUPLEX RECEPTACLE FOR: SECURITY CONTROL ALARM PANEL (1) 2-DATA PORT FOR: EMS DATA CONCENTRATOR POWER & DATA RECEPTACLES (IN WALL, AT MUSIC SYSTEM SHELF) (1) DUPLEX RECEPTACLE FOR: MUSIC SYSTEM AMPLIFIER AND FUTURE USE (1) 2-DATA PORT FOR: CURIO POWER, TELEPHONE & DATA RECEPTACLES (IN WALL, BELOW DESK) (1) QUAD RECEPTACLE FOR: PC, PRINTER, PHONE AND HPC (1) QUAD RECEPTACLE FOR: LAPTOP, CASH SCALE AND FUTURE USE (1) QUAD RECEPTACLE (1) PHONE MAIN (1) 2-DATA PORT FOR: PC AND PRINTER DESK A B C 1" 50MM EQ EQ CASH SCALE 2'-2-1/4" (760MM)PLAN VIEW 2' - 6 " ( 7 6 0 M M ) . (3) SLEEVES FOR LOW VOLTAGE CABLE BUNDLES MOUNTED TO (2) UNISTRUTS EQUIPMENT RACK D POWER RECEPTACLES (IN WALL, AT BACK OF EQUIPMENT RACK) (1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR: UPS (1) DUPLEX RECEPTACLE FOR: PDU STRIP AND FUTURE USE ROLLING CART (BELOW) MAINTAIN 24" (610MM) MIN. CLEARANCE FOR WHEN EQUIPMENT RACK IS IN OPEN ACCESS POSITION 2'-6"(760MM)MINI GROUND BAR FOR EQUIMENT RACK. GC TO COORDINATE RACK GROUNDING TO BAR WITH #6 GROUND WIRE AND PER JURISDICTIONAL REQUIREMENTS ELEVATION VIEW 2 43" W X 42" H (1090MM W X 1070MM H) MIN. 3/4" FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE & FINISH AS SCHEDULED. PRINTER. ROLLING CART EQUIPMENT RACK WALL MOUNTED TO STRUCTURE BY STARBUCKS VENDOR (GC TO COORDINATE INSTALLATION). GROUND RACK PER MFR'S ASSEMBLY INSTRUCTIONS. SEE EQUIPMENT RACK SCHEDULE BELOW FOR EQUIPMENT INCLUDED WITHIN. SECURE KEY BOX LOW VOLTAGE CABLE BUNDLES SECURITY PANEL FUTURE USE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 SECURITY 321 .. 4" 100MM ENLARGED VIEW (3) 3" (76 MM) Ø SLEEVES FOR LOW VOLTAGE CABLE BUNDLES MOUNTED TO (2) UNISTRUTS LAY-IN CEILING CEILING TRIM RING (TYP.) 1 MUSIC PLAY NETWORK SPEAKERS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 POS HIGH SPEED INTERNET DEMARC EXTENSION POS LAN DT TIMER 1'-0" 305MM MOUNT GROUND BAR AT 92" (2335MM) A.F.F. MOUNT EQUIPMENT RACK AT 62" (1575MM) A.F.F. MAINTAIN 24" (305MM) MIN. CLEAR FOR EQUIP. RACK IN OPEN ACCESS POSITION) ACCESS. SEE PLAN VIEW ABOVE POWER & DATA RECEPTACLES AT 75 1/2" (1920MM) A.F.F. TO CENTER OF GROUPING. SEE NOTE 'D' ABOVE FOR DESCRIPTION. 1" 25MM ENLARGED VIEW IOT GATEWAY. . PROVIDE MIN. 18" (460MM) CLEAR ABOVE EQUIPMENT RACK TO UNDERSIDE OF CEILING FOR VENTILATION Scale: 3/4" = 1'-0"1 MANAGERS DESK, EQUIPMENT RACK - ELECTRICAL P1A-19 MANAGER'S DESK #1 MANAGER'S DESK #2 P1A-21 P1A-23 MANAGER'S DESK #3 P1A-25 P1A-27 EQUIPMENT RACK #2 EQUIPMENT RACK #1 RECEPTACLE FOR ICE MACHINE AT 72" (1830MM) A.F.F. 6" (152MM) MIN. CLEAR TO BACK WALL BACK WALL . RECEPTACLE FOR FUTURE USE AT 72" (1830MM) A.F.F. ICE BIN DEDICATED RECEPTACLE FOR INSTANT HOT WATER BOILER AT 26" (660MM) A.F.F. 8" (200MM) DUPLEX RECEPTACLE AND DATA PORT AT 47" (1190MM) A.F.F. SHELVING ABOVE RECEPTACLE FOR REFRIGERATOR AND/OR FREEZER AT 84" (2135MM) AFF BACK WALL Scale: 3/4" = 1'-0"6 CBE ELECTRICAL UNDERCOUNTER REFRIGERATORS UNDERCOUNTER NITROGEN GENERATOR UNDERCOUNTER NITRO REFRIGERATOR UNDERCOUNTER REFRIGERATORS 2 22 RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR BLENDER(S)* RECEPTACLE FOR LABEL PRINTER 2-DATA PORT FOR LABEL PRINTER 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F.RECEPTACLE FOR UNDERCOUNTER NITROGEN GENERATOR RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR BLENDER(S)* RECEPTACLE FOR FUTURE USE 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER REFRIGERATORS DEDICATED RECEPTACLE FOR ESPRESSO MACHINE DEDICATED RECEPTACLE FOR INSTANT HOT WATER BOILER RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. IoT MODULE FOR ESPRESSO MACHINE, FOIO (TYP. 1 OF 2) (2) RECEPTACLES FOR LABEL PRINTERS AND/OR CONNECT DEVICES 2-DATA PORT FOR LABEL PRINTERS AND/OR CONNECT DEVICES 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 21” X 3” (533MM X 76MM) STUB-UP PENETRATION AREA. SUPPLY POWER AND DATA CONDUIT FOR ESPRESSO MACHINES, INSTANT HOT WATER BOILERS AND ADJACENT NITRO WORKSTATION AS APPLICABLE. SEE BUILDING FLOOR PENETRATION FOR FINAL LOCATION. DEDICATED RECEPTACLE FOR ESPRESSO MACHINE DEDICATED RECEPTACLE FOR INSTANT HOT WATER BOILER RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. UNDERCOUNTER WATER BOILER FOR INSTANT HOT WATER FONT (TYP. 1 OF 2) 2 2 IoTIoT Scale: 3/4" = 1'-0"5 ESP ELECTRICAL SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-501 ELECTRICAL DETAILS Scale: 3/4" = 1'-0"4 WRM - ELECTRICAL Scale: 3/4" = 1'-0"2 STUB UPS - ESPRESSO BAR Scale: 3/4" = 1'-0"5 STUB UPS - POS Scale: 3/4" = 1'-0"3 POS - ELECTRICAL GENERAL NOTES A.ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL PLACEMENT. B.PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED PER CONDITIONS. C.TRENCHING OUTLINE FOR GUIDELINE ONLY. GENERAL CONTRACTOR TO COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE ACTUAL LAYOUT. KEYED NOTES 1.ALL CONDUITS TO STUB UP AND ROUTE THROUGH WALL TO ABOVE CEILING, THEN PROCEED ABOVE CEILING(S) TO PANELBOARD AND/OR DATA RACK. 2.SAW CUT FLOOR WHERE REQUIRED. 3.COMMUNITY SEATING POWER. PROVIDE LEGRAND OMNIBOX OR EQUAL WITH FLUSH FLOOR BOX COVER FOR WIREMOLDS. SEE ARCHITECTURAL DETAILS FOR FINAL LOCATION. Scale: 3/4" = 1'-0"8 SANITIZING WORKSTATION - ELECTRICAL Scale: 3/4" = 1'-0"6 OVEN COMBI - ELECTRICAL POWER AND DATA RECEPTACLE AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. ·RECEPTACLE FOR OVEN COMBI ·DATA PORT FOR OVEN COMBI POWER RECEPTACLE AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. ·RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR 1 EQ EQ 4- 1 / 2 " EQ EQ 2'-7" DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 2 3 3 3 3 5- 1 / 4 " ESPRESSO BAR DIEWALL 1 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION 2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION 3 3/4" ISOLATED GROUND POWER CONDUIT ESPRESSO BAR ELECTRICAL STUB-UP KEY NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 1 3/4" POWER CONDUIT TO ELECTRICAL PANEL 2 1/2" PHONE TO MANAGER'S DESK 3 1/2" DATA CONDUIT TO MANAGER'S DESK POS ELECTRICAL STUB-UP KEY 4 1/2" SECURITY TO MANAGER'S DESK 5 3/4" LAN CONDUIT TO POS/SAFE 6 3/4" POWER CONDUIT FOR PASTRY CASE POS DIEWALL EQ EQ 4- 1 / 2 " EQ EQ 2'-3" 10 - 1 / 2 " 1 2 5 634 NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. RECEPTACLE FOR SANITIZER AT 18" (460MM) A.F.F. BACK WALLQUAD RECEPTACLE FOR GRINDER, SCALE AND FUTURE USE DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. Scale: 3/4" = 1'-0"7 BREW ELECTRICAL DEDICATED RECEPTACLE FOR BREWER DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 1'-3"3'-2-1/4" 6'-6" 3'-6-1/4" 42 2 DEDICATED QUAD RECEPTACLE FOR DT DIGITAL PRODUCTION MONITOR, UPS UNIT (FOR TENDERING REGISTER EXPEDITOR, POS AND PED) AND FUTURE USE DEDICATED QUAD RECEPTACLE FOR FUTURE USE 2-DATA J-BOX 4-DATA J-BOX POWER AND DATA RECEPTACLES DEDICATED QUAD RECEPTACLE FOR DRIVE THRU TIMER MONITOR AND CONTROL UNIT. (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE AND SIGNAL PROCESSOR WITH CIRCUIT ISOLATED GROUND 2-DATA J-BOX SINGLE DATA J-BOX POWER AND DATA RECEPTACLES QUAD RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE POWER RECEPTACLE UNDERCOUNTER REFRIGERATOR DUPLEX CONVENIENCE POWER RECEPTACLE EDGE OF COUNTERTOP NOTE:EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE DRIVE THRU WIRELESS HEADSET BASE STATION DRIVE THRU TIMER MONITOR FUTURE HHOP CABLING TO HEADSET BASE STATION FROM J-BOX AT CLG/WALL FOR EXTERNAL EXTENDED COVERAGE ANTENNA (FOIO) DRIVE THRU DIGITAL PRODUCTION MONITOR 4' - 1 0 " ELEVATION VIEW DRIVE THRU TENDERING REGISTER TRIPLE MONITOR MOUNT (GC INSTALLED) SEE PLAN VIEW FOR MOUNTING LOCATION POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. DEDICATED QUAD RECEPTACLE FOR DT DIGITAL PRODUCTION MONITOR, UPS UNIT (FOR TENDERING REGISTER, EXPEDITOR POS AND PED) AND FUTURE USE DEDICATED QUAD RECEPTACLE FOR FUTURE USE 2-DATA PORT FOR TENDERING REGISTER AND EXPEDITOR POS 4-DATA PORT FOR DT VIDEO, PED AND/OR CONNECT DEVICES POS BANK (TYP) CASH DRAWERS ELEVATION VIEW DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO DT VIDEO DATA BOX AT 28" (711MM) A.F.F. DRIVE THRU TIMER CONTROL UNIT POWER AND DATA RECEPTACLES AT 8'-2" (2490MM) TO TOP OF RECEPTACLES A.F.F. DEDICATED QUAD RECEPTACLE FOR DRIVE THRU TIMER MONITOR AND CONTROL UNIT (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE AND SIGNAL PROCESSOR WITH CIRCUIT ISOLATED GROUND 2-DATA PORT FOR DT TIMER AND CONTROL UNIT SINGLE DATA PORT FOR DT AUDIO (MIC & SPEAKER) DRIVE THRU TIMER SIGNAL PROCESSOR (TSP) 36" W X 51" H (915MM W X 1295MM H) MIN. FIRE RATED PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE. WALL FINISH TO CONCEAL. DRIVE THRU EXPEDITOR POS RECEIPT PRINTER DT AUDIO CONDUIT FROM DRIVE THRU ORDER POINT AND DETECTOR LOOP CONDUIT FROM DT WINDOW TO DT TIMER CONTROL DATA JUNCTION BOXES AT 8'-2" (2490MM) POWER RECEPTACLE AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. QUAD RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AND FUTURE USE SINGLE DOOR REFRIGERATOR DUPLEX CONVENIENCE OUTLET AT 45" (1143MM) TO TOP OF RECEPTACLE A.F.F. 5" 2'-5-1/2" DIMENSIONS INDICATE CENTER MOUNTING POINT FOR MONITOR BASE * Scale:NOT TO SCALE1DTP ELECTRICAL1 P1A-20 DTP RECEPTS. #1 REFER TO POWER PLAN P1A-22 DTP RECEPTS. #2 P1A-26 DTP RECEPTS. #4 P1A-24 DTP RECEPTS. #3 UNDERCOUNTER SAFE 18" X 3" (457MM X 76MM) STUB-UP PENETRATION AREA. SUPPLY POWER, DATA AND PHONE CONDUITS FOR POS AND POWER CONDUIT FOR PASTRY CASE. SEE BUILDING FLOOR PENETRATION PLAN FOR FINAL LOCATION. 2 2 2 DEDICATED RECEPTACLE FOR POS 2-DATA PORT FOR POS AND FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. EDGE OF COUNTERTOP EDGE OF CABINET SHELVING (BELOW) DEDICATED RECEPTACLE FOR UPS (POS AND PED) 2-DATA PORT FOR POS, PED AND/OR CONNECT DEVICES POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. QUAD RECEPTICLE FOR FUTURE USE 2-DATA PORT FOR FUTURE USE POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 2 UNDERCOUNTER REFRIGERATOR UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR (2) DEDICATED RECEPTACLE FOR WARMING 2-DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR QUAD RECEPTACLE FOR LABEL PRINTER, FUTURE USE AND/OR CONNECT DEVICES 2-DATA PORT FOR LABEL PRINTER POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F. 2 SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description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ommunicating Lighting Control SALES LIGHTS SIGN LIGHTS SITE LIGHTS WORK LIGHTS OVERRIDE Disconnect Power Before Opening HIGH VOLTAGE WARNING: SURVEYOR SURVEYOR SURVEYOR [minutes] 120 0 [minutes] 120 0 [minutes] 120 0 [minutes] 120 0 WORK LIGHTS OVERRIDE WORK LIGHTS OVERRIDE WORK LIGHTS OVERRIDE WORK LIGHTS MOTION SENSORS 1 OR MORE AS NECESSARY DATA CONCENTRATOR DATA CONCENTRATOR POWER SUPPLY SURVEYOR CAT-5 ETHERNET CABLE CONNECTED TO NETWORK ROUTER. SURVEYOR RS-485 COMM CONNECT TO ALL DEVICES HOME-RUN WHEN POSSIBLE CONNECT ETHERNET CABLE TO LAN PORT #37 ON ROUTER IN DATA RACK LAN 1 3 5 7 2 4 6 8 PHOTOCELL MOUNTED OUTDOORS, TYPICALLY ON ONE HVAC SURVEYOR RS-485 COMM LIGHTING CONTROL BOARD LIGHT SENSOR PUSH BUTTON SECURITY ALARM MOTION SENSOR RS485 LIGHTING CONTROL PANEL BUILT IN CONTACTORS CONNECT TO LIGHTING CIRCUITS PER ZONES ON ELECTRICAL PLANS C-1 INTERIOR WORK C-2 INTERIOR SALES MOTION DETECTORS 1 OR MORE AS NEEDED (TYPICALLY 2 REQUIRED) C-3 EXTERIOR SIGN C-3A EXTERIOR SIGN C-4 PARKING SITE C-4A PARKING SITE 4 Venstar EMS - Full Lighting Control - HVAC Controls 1 Venstar EMS - Full Lighting Control - Basic Low Voltage Wire Runs2Venstar EMS - Full Lighting Control - Data Concentrator3Venstar EMS - Full Lighting Control INTERIOR BOH VENSTAR LCP EF-1 FAN SPEED CONTROL SWITCH IF NEEDED. RELAY REQUIRED (R8222 OR SIMILAR). MOTOR RATED RELAY CONTACTOR. A 2 BOH LIGHTING CKT N EF-1 CKT N 1 2 1 2 DURING OCCUPIED MODE THE EXHAUST FAN MOTOR DAMPER SHALL OPEN AND FAN SHALL START. DURING UNOCCUPIED MODE THE EXHAUST FAN MOTOR DAMPER SHALL BE CLOSED AND FAN SHALL BE OFF. N.T.S.5 EXHAUST FAN CONTROL WIRING DIAGRAM N.T.S. N.T.S.N.T.S.N.T.S. SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-503 ELECTRICAL EMS DETAILS EXISTING PANELBOARD NOTES 1.THESE PANELBOARD SCHEDULES WERE CREATED USING THE SCHEDULES INSIDE THE EXISTING PANELBOARDS, SURVEY NOTES, SURVEY PHOTOS AND/OR THE ORIGINAL CONSTRUCTION DRAWINGS. ACTUAL CIRCUIT CONNECTIONS AND LOADS MAY VARY FROM THIS SCHEDULE. THE CONTRACTOR SHALL VERIFY THE EXISTING CIRCUITS IDENTIFYING THE ACTUAL LOADS SERVED. THE CONTRACTOR SHALL PROVIDE NEW PANELBOARD SCHEDULES AND PLACE INSIDE EACH PANELBOARD. COPIES OF THESE SCHEDULES SHALL BE PROVIDED TO OWNER. 2.THE CONTRACTOR IS CAUTIONED THAT THE EXISTING PANEL SCHEDULES MAY NOT BE REPRESENTATIVE OF THE ACTUAL LOADS SERVED BY EACH CIRCUIT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EACH EXISTING CIRCUIT, IDENTIFYING ACTUAL LOAD SERVED AND MEASURE ACTUAL PANEL LOAD. MAKE ADJUSTMENTS REQUIRED TO ACCOMMODATE NEW BREAKERS WHERE REQUIRED. RE-BALANCE ALL PANEL LOADS. PROVIDE NEW CIRCUIT DIRECTORIES REFLECTING ALL NEW AND EXISTING LOADS. ANY ADJUSTMENTS SHALL BE COORDINATED WITH OWNER'S REPRESENTATIVE. GROUND FAULT PROTECTION NOTES ·PROVIDE GFCI PROTECTION AS REQUIRED BY NEC 210.8. ·CIRCUITS REQUIRING GFCI PROTECTION IDENTIFIED WITH 'G' ON PANEL SCHEDULES (THIS SHEET). ·ABOVE-COUNTER RECEPTACLES THAT ARE READILY ACCESSIBLE AND WITHIN REACH OF PARTNERS SHALL BE GFCI TYPE. ·BELOW-COUNTER RECEPTACLES, OR RECEPTACLES THAT ARE DIFFICULT TO REACH OR REQUIRE MOVING EQUIPMENT TO RESET, AND ARE NOT READILY ACCESSIBLE SHALL BE PROTECTED BY GFI CIRCUIT BREAKERS. ·WHERE THE AVAILABLE SHORT CIRCUIT CURRENT EXCEEDS 22,000 AMPS AT THE PANELBOARD, CONTACT CIRCUIT BREAKER MANUFACTURER AND PROVIDE GFCI TYPE CIRCUIT BREAKER THAT SERIES RATES WITH PANEL OVER CURRENT PROTECTION IF AVAILABLE. ·WHERE THE AVAILABLE SHORT CIRCUIT CURRENT EXCEEDS 22,000 AMPS AT THE PANELBOARD, AND GFCI BREAKERS ARE NOT AVAILABLE, PROVIDE DEAD-FRONT GFCIS (IN A READILY ACCESSIBLE LOCATION) TO SERVE RECEPTACLES THAT ARE NOT READILY ACCESSIBLE. EXISTING SINGLE LINE DIAGRAM SCALE: N.T.S. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY VOLTAGE DROP OF ALL FEEDER/BRANCH CIRCUIT COMBINATIONS BASED ON ACTUAL CONDUCTOR LENGTHS PER ROUTING IN FIELD AND UPSIZE CONDUCTORS AS REQUIRED SUCH THAT VOLTAGE DROP DOES NOT EXCEED 5% FOR ANY FEEDER/BRANCH CIRCUIT COMBINATION. EXISTING ELECTRICAL DISTRIBUTION IS EXISTING TO REMAIN. NO WORK AS PART OF THIS PROJECT. EXISTING ELECTRICAL DISTRIBUTION AND PANEL CONFIGURATIONS IS SHOWN PER SHELL ELECTRICAL DRAWINGS, DATED 03/25/24 FOR INFORMATION ONLY. FIELD VERIFY ALL CONDITIONS PRIOR TO START OF WORK. PER LANDLORD WORK LETTER, ALL BRANCH BREAKERS WILL BE EXISTING/PROVIDED WITH PANELS IN THE SHELL PORTION OF THE PROJECT, AS SHOWN ON TENANT CONTRUCTION PLANS (THIS SET) ON GRADE EXISTING UTILITY XFMR TO REMAIN. EXISTING UTILITY PRIMARY TO REMAIN. PANEL "A"PANEL "B" EXISTING 600A PANEL 'A' TO REMAIN. EXISTING 225A FEEDERS TO REMAIN. EXISTING 225A PANEL 'B' TO REMAIN. EXISTING 600A DISCONNECT SWITCH TO REMAIN. EXISTING GROUNDING SYSTEM TO REMAIN. MEXISTING UTILITY METER TO REMAIN. EXISTING FEEDERS TO REMAIN. EXISTING CT CABINET TO REMAIN. EXISTING UTILITY SECONDARY TO REMAIN. EXISTING 600A FEEDERS TO REMAIN. STARBUCKSEXTERIORADJACENT TENANT ELEC ROOM C1 LIGHTING CONTROL DIAGRAM EXHAUST FAN CONTROL NOTES : WHEN THE STORE IS OPEN, THE EXHAUST FAN MOTOR DAMPER SHALL OPEN AND FAN SHALL RUN. WHEN THE STORE IS CLOSED, THE EXHAUST FAN MOTOR DAMPER SHALL BE CLOSED AND FAN SHALL BE OFF. CONTROL NOTES : 1.ON 1 HOUR BEFORE STORE OPEN. 2.OFF 1 HOUR AFTER STORE CLOSE. LIGHTING CONTROL NOTES: LIGHTING CONTROL BY VENSTAR EMS SYSTEM. SEE DETAILS ON E-5002 FOR VENSTAR EMS SYSTEM CONNECTION DETAILS. EXHAUST FAN RELAY RECIRCULATION PUMP SPARE c C2 CAFE ACCENT LIGHTING SHOW WINDOW RECEPTS C3 MONUMENT SIGNAGE SPARE SPARE C4 EXTERIOR SITE LIGHTING C5 C6 DT MENU BOARDS DT DIRECTIONAL SIGNAGE BLDG MOUNTED SIGNAGE BUILDING FACADE LIGHTING FIELD VERIFY NUMBER OF CONTACTS REQUIRED FOR EXISTING EXTERIOR LIGHTING. (1) CONTACT PER CIRCUIT REQUIRED. PC VENSTAR LIGHTING CONTROL PANEL CONTROL NOTES : 1.ON 1 HOUR BEFORE STORE OPEN. 2.OFF 1 HOUR AFTER STORE CLOSE. CONTROL NOTES : 1.ON AT STORE OPEN, OFF AT DAWN. 2.ON AT DUSK, OFF AT STORE CLOSE. CONTROL NOTES : 1.ON AT STORE OPEN, OFF AT DAWN. 2.ON AT DUSK, OFF AT STORE CLOSE. CONTROL NOTES : 1.ON AT STORE OPEN, OFF AT DAWN. 2.ON AT DUSK, OFF AT STORE CLOSE. CONTROL NOTES : 1.ON AT STORE OPEN. 2.OFF AT STORE CLOSE. A-11 SPARE a b ENGINE LIGHTING CAFE LIGHTING d e CAFE/ENGINE TAPE LIGHT f RESTROOM VESTIBULE ENGINE PENDANT g h WORKROOM CAFE SCONCE LIGHTING EXTERIOR WALL LIGHTING EXTERIOR POLE SPARE SPARE SPARE SPARE SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 LJG LJG WHS Revision Schedule Rev Date By Description E-601 PANELBOARD SCHEDULES M-001 GENERAL MECHANICAL NOTES GENERAL NOTES SCOPE SITE EXAMINATION PENETRATIONS STANDARDS CODES PERMITS AND FEES WARRANTY TESTING, ADJUSTING, BALANCING HVAC EQUIPMENT AND MATERIALS AIR HANDLING UNITS FILTERS EXHAUST FANS AIR CURTAINS NATURAL GAS PIPING SYSTEM. BRACING AND ANCHORING DUCTWORK AND ACCESSORIES SHEET METAL DUCTWORK DUCT SEALANT SUPPORTS DAMPERS GRILLES, REGISTERS, AND DIFFUSERS THERMAL INSULATION ACOUSTICAL DUCT LINER FLEXIBLE DUCTWORK AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION APPROX APPROXIMATE BLDG BUILDING CO2 CARBON DIOXIDE CD CEILING DIFFUSER CLG CEILING CONST CONSTRUCTION CXA COMMISSIONING AGENT DEG DEGREES DM STARBUCKS DESIGN MANAGER DN DOWN DTL DETAIL DWG(S)DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR ECP EQUIPMENT CONTROL PAC EG EXHAUST GRILLE ELEC ELECTRICAL EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EXIST EXISTING EXT EXTERIOR F&I FURNISH & INSTALL FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER, INSTALLED BY OWNER FLR FLOOR FT FOOT/FEET G GAS PIPING GC GENERAL CONTRACTOR HR HOUR HVAC HEATING, VENTILATION, AIR CONDITIONING I.D.INSIDE DIAMETER IAQ INDOOR AIR QUALITY LCP LIGHTING CONTROL PANEL LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MECH MECHANICAL MEP MECHANICAL, ELECTRICAL AND PLUMBING MFG MANUFACTURER MIN MINIMUM NTS NOT TO SCALE O.D.OUTSIDE DIMENSION OSA OUTSIDE AIR REF REFERENCE REQ'D REQUIRED REV REVISION RT ROOFTOP SF SQUARE FEET SHT SHEET SPECS SPECIFICATION(S) SST STAINLESS STEEL TEMP TEMPORARY TYP TYPICAL UNO UNLESS NOTED OTHERWISE UC UNDER COUNTER WH WATER HEATER WSHP WATER SOURCE HEAT PUMP ABBREVIATIONS ENERGY MANAGEMENT SYSTEM (EMS) A 12"Ø 400 CFM MECHANICAL SYMBOL LEGEND BD D S 12 X 8 12 X 8 TYPICAL SUPPLY DUCT UP/DN TURNING VANES EQUIPMENT DESIGNATIONXX-1 AIRFLOW ARROW DUCT HEATER MANUAL VOLUME DAMPER BACK DRAFT DAMPER SMOKE DETECTOR UNDERCUT DOOR CONNECT TO EXISTING FLEXIBLE DUCT CONNECTION NECK SIZE DESIGN CFM (WHERE APPLICABLE) DIFFUSER TYPE (REFER SCHEDULE) CEILING RETURN GRILLE COMBINATION SMOKE AND FIRE DAMPER SPIN-IN TAKE-OFF AND VOLUME DAMPER INDICATES UNLINED 12" X 8" O.D. SHEETMETAL 1ST FIGURE = SIDE SHOWN 2ND FIGURE = SIDE NOT SHOWN INDICATED 14" X 10" (355mm X 255mm) O.D. SHEETMETAL W/ 1" (25mm) SOUNDLINER (U.N.O), 12" X 8" (305mm X 205mm I.D. NET FLEXIBLE DUCT CEILING DIFFUSER (FLOW ARROWS SHOWN ONLY IF AIR FLOW NOT SYMMETRICAL) THERMOSTAT REMOTE THERMOSTAT SENSOR CONTROLS AND OPERATION NOTES THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL THE FOLLOWING COMPONENTS: CONTROL WIRING THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM INCLUDING ALL MODES OF OPERATION AND INTERLOCK. EXHAUST FANS RESTROOM EXHAUST FAN(S) TO BE OPERATED IN CONJUNCTION WITH STORE HOURS UNLESS OTHERWISE NOTED OR APPROVED OR AS REQUIRED BY JURISDICTION (COORDINATE WITH ELECTRICAL). THERMOSTAT THERMOSTAT SETUP INSTRUCTIONS PROVIDE THE FOLLOWING SETUP AND PROGRAMMING: 1.CONFIGURE AS FOLLOWS: A.DEGREES "F" DISPLAY B.12 HOUR CLOCK C.CONTINUOUS FAN OPERATION IN OCCUPIED MODE D.DISABLE KEYBOARD PROGRAMMING 2.SET TIME AND DATE. 3.SET TO DISPLAY CURRENT TEMPERATURE. 4.SET OCCUPIED START TIME AT 30 MIN. BEFORE OPENING. SET UNOCCUPIED START TIME AT 30 MIN. AFTER CLOSING. VERIFY HOURS WITH STORE MANAGER OR CONSTRUCTION MANAGER. 5.SET POINTS SHALL BE AS FOLLOWS OR AS APPROPRIATE FOR CLIMATE: A.OCCUPIED (5° F DEADBAND) (3° C DEADBAND) I.HEATING:70° F (21° C) II.COOLING:75° F (24° C) B.UNOCCUPIED I.HEATING:60° F (15° C) II.COOLING:78° F (25° C) 6.SET TWO (2) HOUR OCCUPIED OVERRIDE FUNCTION TO PROVIDE THE FOLLOWING SET POINT OVERRIDES: A.HEATING:+2° F (1° C) B COOLING:-2° F (1° C) DEMAND CONTROL VENTILATION (DCV) THE C02 SENSOR SHALL MODULATE THE AIR HANDLING UNIT OUTSIDE AIR DAMPER TO MAINTAIN 1000 PPM C02 OR LESS OCCUPIED MODE: 1.FAN SHALL RUN CONTINUOUSLY WHILE BRINGING IN MINIMUM DCV OUTSIDE AIR AS INDICATED IN SCHEDULE. 2.IF C02 SENSOR SET POINT IS BELOW THE SETPOINT, THE AIR DAMPER SHALL BE OPEN TO THE CALCULATED DCV MINIMUM OUTSIDE AIR. 3.IF C02 SENSOR SETPOINT IS EXCEEDED, OUTSIDE AIR DAMPER SHALL MODULATE TO MAINTAIN 1000 PPM NOT TO EXCEED THE CALCULATED DESIGN MINIMUM OUTSIDE AIR. 4.UPON C02 PPM FALLING BELOW THE SETPOINT, THE AIR DAMPER SHALL RETURN TO DCV MINIMUM OUTSIDE AIR. 5.THE ECONOMIZER SHALL HAVE PRIORITY OVER THE DCV CONTROLS, OUTSIDE AIR MAY EXCEED DCV MINIMUM AND DESIGN MINIMUM WHEN AIR CONDITIONS ARE APPROPRIATE TO DO SO. UNOCCUPIED MODE: 1.FAN SHALL CYCLE WITH HEATING AND OUTSIDE AIR DAMPER CLOSED. OUTSIDE DAMPER SHALL NOT BE CYCLED WITH C02 PPM SETPOINT. IAQ MANAGEMENT PLAN DURING CONSTRUCTION, CONTRACTOR SHALL COMPLY WITH CHAPTER 3 OF SMACNA’S IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION. CONTRACTOR SHALL PERFORM AND SUBMIT ALL INFORMATION AS REQUIRED. IF HVAC SYSTEM IS TO BE USED DURING CONSTRUCTION, INSTALL MERV 13 FILTERS AT EACH RETURN AIR GRILL AND COMPLY WITH SMACNA’S GUIDELINES REFERENCED BELOW. INDEPENDENT AIR BALANCE CONTRACTOR OR QUALIFIED MECHANICAL CONTRACTOR SHALL BE QUALIFIED TO TAB WORK BY NEBB OR AABC STANDARDS. BALANCER SHALL ACCURATELY BALANCE THE SUPPLY, RETURN AND OUTSIDE AIR, EXHAUST FAN(S), HYDRONIC (WHERE APPLICABLE) AND EXHAUST FAN(S) SYSTEMS TO PROVIDE AIR AND WATER QUANTITIES WITHIN 10% PLUS OR MINUS OF THE VALUES INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS. OPERATE AUTOMATIC CONTROLS SYSTEMS AND VERIFY SETPOINTS FOR THERMOSTATS, C02 SENSORS, DCV, EMS AND ECONOMIZER/OUTSIDE AIR DAMPER. SEE CONTROLS AND OPERATION NOTES AND HVAC SCHEDULES AND NOTES FOR DETAILS. IF DEFICIENCIES OR SITE CONDITIONS PREVENT COMPLETE AND PROPER BALANCING, DO NOT COMPLETE WORK AND SUBMIT A REQUEST FOR INFORMATION TO GET COMPLETE INFORMATION PRIOR TO COMPLETING WORK. SUBMIT THREE (3) COPIES OF THE BALANCE REPORT TO THE ENGINEER, CONSTRUCTION MANAGER AND COMMISSIONING AGENT FOR APPROVAL. THE BALANCE REPORT SHALL INCLUDE NEBB OR AABC CREDENTIALS, EQUIPMENT/INSTRUMENT LIST WITH THE MOST RECENT CALIBRATION DATE AND BALANCE REPORTS FOR ALL HVAC AND EXHAUST SYSTEMS. INCLUDE A COPY OF THE BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT. ALSO PROVIDE A TAB REPORT TO THE INSPECTOR AT THE FINAL INSPECTION. AIR HANDLING UNITS SHALL BE AS SPECIFIED IN THE MECHANICAL SCHEDULE AND SHALL BE FURNISHED AND INSTALLED PER THE LEASE AGREEMENT. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY, PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, PIPING, VIBRATION ISOLATION, AND NECESSARY ACCESSORIES, AND PROVIDING WARRANTY. IF OPERATING HVAC DURING CONSTRUCTION, PROVIDE THREE (3) SETS OF 2" (51MM) MERV13 PLEATED DISPOSABLE FILTERS (OR HIGHER RATING IF REQUIRED BY LEED). USE ONE SET UNTIL COMPLETION OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION (PRIOR TO TAB) AND DELIVER ONE SET OF MERV13 FILTERS TO STARBUCKS LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING UNIT. EXHAUST FANS SHALL BE AS SPECIFIED AND PROVIDED PER THE LEASE AGREEMENT. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS AND INTAKES, PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, BACKDRAFT DAMPER, DUCTWORK FROM RESTROOM GRILLE TO UNIT, NECESSARY ACCESSORIES AND PROVIDING WARRANTY. AIR CURTAINS, WHEN REQUIRED, SHALL BE FURNISHED BY OWNER WITH WINDOW UNIT FROM READY-ACCESS AND INSTALLED BY THE GENERAL CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF POWER CONNECTION. ALL OTHER AIR CURTAINS SHALL BE FURNISHED BY THE CONTRACTOR. PROVIDE NATURAL GAS PIPING FROM GAS COMPANY METER TO EACH PIECE OF EQUIPMENT OR APPLIANCES IN ACCORDANCE WITH CODE AND THE PROJECT MANUAL. PRESSURE REGULATORS FOR MEDIUM PRESSURE SYSTEMS SHALL BE VENTED TO THE OUTDOORS. PROVIDE PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING ALL MECHANICAL EQUIPMENT, FIXED OR FLEXIBLY MOUNTED, SHALL BE BRACED OR ANCHORED TO COMPLY WITH LOCAL CODES. SEE SPECIFICATIONS FOR SHEET METAL DUCT REQUIREMENTS. ALL EXPOSED DUCTWORK TO BE SPIRAL ROUND, OR RECTANGULAR LOCK-SEAM TYPE, AS SHOWN ON HVAC PLAN SHEET. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH AND INSTALL ALL REQUIRED DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS PER SPECIFICATIONS. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN-IN FITTINGS, AND FASTENING SCREWS WITH MASTIC. PROVIDE FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. SUPPORTS MUST COMPLY WITH LOCAL REGULATIONS AND CODE. PROVIDE VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL LISTED FIRE OR FIRE/SMOKE DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVENIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. PROVIDE MOTORIZED DAMPERS AT ALL INTAKE & EXHAUST BUILDING OPENINGS. COORDINATE WITH OTHER TRADES FOR ACCESS PANELS, POWER AND FIRE ALARM INTERFACES. SEE PROJECT MANUAL. WHERE VOLUME DAMPERS ARE LOCATED IN IN-ACCESSIBLE AREAS SUCH AS ABOVE DRYWALL CEILINGS, REMOTE DAMPER OPERATORS SHALL BE PROVIDED SO THAT DAMPERS CAN BE ADJUSTED THROUGH THE FACE OF THE DIFFUSERS/GRILLES (BOWDEN REMOTE CABLE CONTROLLERS BY YOUNG REGULATOR, OR EQUAL). GRILLES, REGISTERS, AND DIFFUSERS SHALL BE AS SPECIFIED AND SHALL BE MECHANICAL CONTRACTOR SUPPLIED, UNLESS OTHERWISE NOTED. DIFFUSERS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS PROJECT. PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS OR ASHRAE 90.1-2004, WHICHEVER IS MORE STRINGENT. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT EXTERNALLY INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED WITH CODE REQUIRED THICKNESS. INTERNALLY INSULATE EXPOSED SUPPLY DUCTWORK IF POSSIBILITY OF CONDENSATION. INTERNALLY INSULATE EXTERIOR DUCTWORK PER CODE. R-8 INSULATION MINIMUM. UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" (25MM) ACOUSTICAL DUCT LINER IN SUPPLY AND RETURN DUCTWORK WITHIN 10'-0" (305CM) OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZE INDICATED ON PLANS AS NEEDED TO ACCOMMODATE LINER. LINER TO BE PROVIDED AND FASTENED TO DUCT WITH MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMACNA AND PROJECT MANUAL. FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS SHOWN IN PLAN AND NOT ABOVE HARD LID CEILINGS. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5’-0" (152CM) IN LENGTH AND TWO 45° ELBOWS. IT SHALL BE PULLED TAUT AND APPROPRIATELY FASTENED TO RIGID BRANCH DUCT & DIFFUSER. BENDS SHALL BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND. SUPPORT BANDS SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT. FLEXIBLE DUCTWORK SHALL MEET REQUIREMENTS. THE MECHANICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND PROJECT MANUAL AND THE CODES AND ORDINANCES, USE WHICHEVER IS MORE STRINGENT. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. THE BUILDING SHALL MEET OR EXCEED THE PROVISIONS FOR MECHANICAL VENTILATION OF CAL GREEN CODE. EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE PROVISIONS OF CSA, ULC, ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. WHERE PIPES AND DUCTS PENETRATE WALL, SEAL OPENINGS TO PREVENT AIR TRANSFER BETWEEN SPACES. USE FIRE RATED SEALANTS ON ALL FIRE SEPARATION PENETRATIONS, INCLUDING FLOORS. SEAL AROUND ALL PIPES AND DUCTS PENETRATING FIRE SEPARATIONS WITH NON-COMBUSTIBLE PACKING RETAINED BY METAL COLLARS. THE ASSEMBLY SHALL BE APPROVED BY STATE FIRE MARSHALL. 1.MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 2.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FURNISH & INSTALL ALL COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A COMPLETE AND OPERATING SYSTEM. 3.CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS. 4.THE MECHANICAL CONTRACTOR SHALL COORDINATE HVAC WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND PROJECT MANUAL SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. SEE ARCHITECTURAL DRAWINGS AND PROJECT MANUAL FOR DIMENSIONED DIFFUSER LOCATIONS AND MOUNTING HEIGHTS WHERE EXPOSED. 5.NEW DUCTWORK AND EQUIPMENT SHALL NOT BE INSTALLED WHERE IT OBSTRUCTS ANY EXISTING OR NEW AREAS THAT REQUIRE ACCESS. WHEN AN ENERGY MANAGEMENT SYSTEM IS TO BE INSTALLED, THE CONTRACTOR SHALL COORDINATE WITH THE EMS VENDOR FOR A COMPLETE CONTROL SYSTEM. FURNISH AND INSTALL ALL LOW VOLTAGE WIRING THROUGH EC PROVIDED CONDUITS (COORDINATE WITH ELECTRICAL). EMS VENDOR SHALL PROVIDE ONE THERMOSTAT AND REMOTE SENSOR PER HVAC UNIT. LOCATE AND MOUNT THERMOSTAT(S) AND SENSOR(s) PER THE DRAWINGS. PROVIDE THERMOSTAT IDENTIFICATION LABELS PER SPECIFICATION REQUIREMENTS. VENDOR SHALL PROGRAM AND COMMISSION CONTROL SYSTEM. EMS THERMOSTATS SHALL BE PROGRAMMED TO MEET LOCAL CODE REQUIREMENTS. TYPICAL RETURN DUCT UP/DN TYPICAL EXHAUST DUCT UP/DN CEILING EXHAUST GRILLE TYPICAL SUPPLY DUCT UP THRU ROOF TYPICAL RETURN DUCT UP THRU ROOF TYPICAL EXHAUST DUCT UP THRU ROOF SUPPLY GRILLE RETURN GRILLE PERMANENT THERMOSTAT(S) AND REMOTE SENSOR(S) SHALL BE FURNISHED AND INSTALLED. ONE THERMOSTAT AND SENSOR IS PROVIDED FOR EACH AIR HANDLING UNIT. MOUNT THERMOSTAT(S) AND SENSOR(S) IN LOCATION & HEIGHT AS INDICATED ON DRAWINGS. MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT IDENTIFICATION LABELS PER SPECIFICATION REQUIREMENTS. REFER TO THERMOSTAT SETUP INSTRUCTIONS BELOW FOR ADDITIONAL REQUIREMENTS. REMOTE TEST STATION SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description M-001 MECHANICAL NOTES M-101GENERAL NOTES OVEN VENTLESS CERTIFICATION NOTE: STARBUCKS DOES NOT COOK FOOD. ALL FOOD IS SHIPPED TO THE STORES PRE-COOKED AND PACKAGED. THE STORES ONLY USE THE WARMING OVENS TO WARM UP THE FOOD. THE WARMING OVENS ARE VENTLESS CERTIFIED AND UL LISTED, UL 710B, REFER TO CUT SHEET. IT SHOULD BE SPECIFICALLY NOTED, PER CUTSHEET VENTLESS REQUIREMENTS, THAT NO FOODS CLASSIFIED AS "FATTY RAW PROTEINS" ARE COOKED IN THE STORE. KEYNOTES 1.CONNECT TO EXISTING SUPPLY ROOFTOP DUCT DROP BY LANDLORD AND EXTEND THRU SPACE AS SHOWN. 2.CONNECT TO EXISTING RETURN ROOFTOP DUCT DROP BY LANDLORD AND EXTEND THRU SPACE AS SHOWN. 3.CONNECT TO EXISTING EXHAUST ROOFTOP DUCT DROP BY LANDLORD AND EXTEND THRU SPACE AS SHOWN. 4.1" UNDERCUT ON DOOR. 5.WALL MOUNTED THERMOSTAT(S) & REMOTE TEST STATIONS. REFER TO MECHANICAL NOTES, MECHANICAL SCHEDULES, AND MECHANICAL SPECIFICATIONS FOR THERMOSTAT REQUIREMENTS, SOURCING, AND RESPONSIBILITY. MULTIPLE THERMOSTATS SHALL BE STACKED IN A VERTICAL CONFIGURATION WITH A MINIMUM 8" CLEARANCE BELOW EACH THERMOSTAT. COORDINATE FINAL LOCATION OF REMOTE TEST STATION WITH FIRE MARSHALL PRIOR TO ROUGH-IN. 6.REMOTE TEMPERATURE SENSOR AT 60" A.F.F. AND CO2 SENSOR AT 48" A.F.F., FURNISHED AND INSTALLED BY HVAC CONTRACTOR. FIELD VERIFY ALL REQUIREMENTS. 7.NOT USED. 8.DRIVE-THRU/WALK-UP AIR CURTAIN. 9.PROVIDE DOOR SWITCH FOR AIR CURTAIN, COORDINATE WITH ELECTRICAL. COORDINATE WITH MANUFACTURER SPECIFICATIONS AND MECHANICAL INSTALLER PRIOR TO ROUGH-IN. CAFE ENGINE WORKROOM RESTROOM VEST. RESTROOM 1 RESTROOM 2 M-101 MECHANICAL PLAN SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description M-102 KEYNOTES 1.EXISTING ROOFTOP PACKAGED HVAC UNIT BY LANDLORD TO REMAIN. 2.EXISTING ROOFTOP EXHAUST FAN PROVIDED BY LANDLORD. 3.MAINTAIN MINIMUM 10FT BETWEEN EXHAUST FAN/SANITARY VENT DISCHARGE LOCATION AND ANY OUTSIDE AIR INTAKES. 4.EXISTING SANITARY VENT THROUGH ROOF. 5.ROOF MOUNTED REMOTE CONDENSING UNIT FOR ICE MACHINE. EXTEND REFRIGERANT PIPING TO ICE MACHINE, SEAL ROOF OPENINGS WEATHER-TIGHT. M-102 MECHANICAL ROOFTOP PLAN SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description M-601 1 LAY IN DIFFUSER N.T.S. 2 DUCT HANGING DETAIL N.T.S. 1.CLASSIFICATION OF "FOOD AND BEVERAGE SERVICE: CAFETERIA, FAST FOOD" RESULTS IN AN ESTIMATED QUANTITY OF PEOPLE ON A SQUARE FOOTAGE BASIS THAT IS UNREALISTIC WITH REGARD TO THE ACTUAL USE OF THE SPACE. THE CALCULATED NUMBER OF PEOPLE HAS BEEN NOTED IN THE ABOVE CALCULATION, BUT AN ALTERNATIVE, REASONABLY CONSERVATIVE ACTUAL MAXIMUM OCCUPANCY (WHICH IS SUPPORTED BY THE OWNER'S HISTORICAL DATA) IS UTILIZED IN THE CALCULATION FOR THE TOTAL OUTSIDE AIR CFM REQUIRED FOR THE RESPECTIVE ZONES. ENERGY MANAGEMENT SYSTEM (EMS) DEVICES DESCRIPTION COMMENTS VENSTAR DC400, DATA CONCENTRATOR VENSTAR CT414, COMMUNICATING THERMOSTAT VENSTAR RS410, WALL MOUNT REMOTE TEMPERATURE SENSOR VENSTAR ECP400, EQUIPMENT CONTROL PACK VENSTAR OTS400, OUTDOOR TEMPERATURE SENSOR LOCATE AT MANAGER'S WORK STATION. LOCATION SHOWN ON SHEET E-501, DETAIL 2. RESPONSIBILITY CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR OPTIONAL SENSOR FOR WORKROOM. USE AS LAST RESORT ONLY IF NO SPACE EXISTS FOR WALL MOUNT TEMPERATURE SENSOR. CONTRACTOR LOCATE ON ROOF IN SHADED LOCATION ON NORTH SIDE OF BUILDING. VENSTAR RS420, OPTIONAL NARROW DROP DOWN SENSOR CONTRACTOR LOCATE AT EACH HVAC UNIT. LOCATION OF HVAC UNITS SHOWN ON SHEET M-101. LOCATE BY MANAGER'S WORK STATION AS SHOWN ON M-101 AND E-103. COORDINATE LOCATION WITH STARBUCKS' EQUIPMENT. LOCATE AS SHOWN ON M-1101, ONE PER HVAC UNIT. COORDINATE LOCATION WITH STARBUCKS' ART, EQUIP.; PROJECT MANAGER. VENSTAR SP400, SENSOR PAC CONTRACTOR LOCATE COMPONENTS (AIRFLOW & TEMP SENSORS) PER SP400 SENSOR PAC INSTALLATION INSTRUCTIONS. NOTES: 1.EMS DEVICES FURNISHED BY EMS VENDOR: VENSTAR. CONTACT: SBUXQUOTES@VENSTAR.COM, 818-812-9805. COMPONENTS INSTALLED BY CONTRACTOR. 2.THE SCHEDULED COMPONENTS SHALL BE PROVIDED FOR A COMPLETE AND FUNCTIONAL SYSTEM. SEE SPECIFICATION ABOUT EMS SYSTEM REQUIREMENTS. ELECTRICAL / MECHANICAL COORDINATION NOTES: PROVIDE AND COORDINATE LINE VOLTAGE WIRING, LINE VOLTAGE CONTROL AND INTERLOCK WIRING FOR MECHANICAL SYSTEMS, AND LOW VOLTAGE CONTROL WIRING. FURNISH WIRING DIAGRAMS TO THE ELECTRICIAN AS REQUIRED FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE ELECTRICIAN THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT (FROM THE EQUIPMENT NAMEPLATE) TO ENSURE PROPER INSTALLATION. 3 PIPE ROOF CURB DETAIL N.T.S. (PROVIDED BY LANDLORD FOR REFERANCE ONLY)4 CONDENSER SUPPORT DETAIL N.T.S. (PROVIDED BY LANDLORD FOR REFERANCE ONLY) M-601 MECHANICAL SCHEDULES SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-001GENERAL PLUMBING NOTES 1.PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 2.EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR AREA UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT CABINETS/DEVICES AND WHERE APPROVED BY STARBUCKS CONSTRUCTION MANAGER. IF ROUTED THROUGH CABINETS, IT SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE PROTECTED FROM DAMAGE. 3.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A COMPLETE AND OPERATING SYSTEM. OVERALL CASEWORK COMPONENT DIMENSIONING ON PLUMBING DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. 4.CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS. 5.THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR FIXTURES IN CASEWORK AND PLUMBING DETAILS. SEE THE PROJECT MANUAL FOR PLUMBING SPECIFICATION SECTIONS. 6.ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM STRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS). ABBREVIATIONS GENERAL NOTES SCOPE THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK. SITE EXAMINATION THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN THEIR OPINION, PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE PROVISIONS OF CSA, ULC, ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK. WARRANTY THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. INSULATION PIPING PLUMBING FIXTURES WATER FILTRATION STARBUCKS WATER FILTRATION VENDOR WILL PROVIDE FILTRATION SYSTEM. CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR IS TO INSTALL FILTRATION SYSTEM. PROVIDE AND COORDINATE INSTALLATION COMPLETE WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE DRAWINGS. CONNECTIONS THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. SCHEDULES REFER TO SCHEDULES ON DRAWINGS FOR A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC". ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO SUPPLIES. VALVES GENERAL PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. SEE PROJECT MANUAL FOR TYPES. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. SHUT OFF VALVES TO BE BALL TYPE. VALVES SHALL BE LISTED/APPROVED FOR USE PER AUTHORITIES HAVING JURISDICTION (AHJ) AND CODE REQUIREMENTS. PROVIDE VALVE IDENTIFICATION PER THE PROJECT MANUAL FOR MAIN WATER SERVICE SHUT-OFF AND ANY OTHER VALVES WHICH ARE NOT CLEARLY EVIDENT WHAT THEY SERVE. SUPPLY WATER SERVICE IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI, PROVIDE A PRESSURE REGULATOR IN MAIN SUPPLY TO REDUCE WATER PRESSURE. PROVIDE BACKFLOW PREVENTION ON WATER SERVICE IF REQUIRED BY LOCAL CODES. THERMOSTATIC MIXING VALVE PROVIDE A SINGLE THERMOSTATIC MIXING VALVE (TMV) LOCATED AT HOT WATER TANK AND SET FOR 120° (OR AS REQUIRED BY AHJ) TO SERVE HAND SINKS. MIXING VALVE TO BE INSTALLED PER MANUFACTURER’S REQUIREMENTS WITH CHECK VALVES AT SUPPLY INLETS. PROVIDE THERMOMETER ON OUTLET OF TMV. SEE THE PROJECT MANUAL FOR REQUIREMENTS. NITROGENATION PLUMBING SYMBOL LEGEND BALL VALVE CONDENSATE DRAIN DOMESTIC HOT WATER DOMESTIC COLD WATER CD NOTE: NOT ALL SYMBOLS MAY BE USED DOMESTIC HOT WATER RETURN COLD WATERCW WASTE BELOW GROUND VENT GREASE WASTEGSAN NATURAL GASG EXISTING PIPING(E) WALL CLEAN OUT FLOOR DRAIN FLOOR SINK BUTTERFLY VALVE GAS SHUT OFF VALVE ANGLE VALVE GLOBE VALVE MOTORIZED T.C. VALVE/2-WAY MOTORIZED T.C. VALVE/3-WAY PRESSURE REDUCING VALVE SAFETY RELIEF VALVE GATE VALVE SWING CHECK VALVE BACKFLOW PREVENTER STRAINER UNION TEE UP TEE DOWN ELBOW UP ELBOW DOWN WATER METERM WATER HAMMER ARRESTER (WHA) HOSE BIBB, EXPOSED CONNECT NEW WORK TO EXISTING(E) POINT OF DISCONNECT(E) PIPE CAP TRAP PRIMER PIPE BREAK 7.REFER TO OULTINE SPECIFICATIONS FOR PLUMBING SPECIFICATION SECTIONS. LEED ALL WORK, MATERIALS AND EQUIPMENT SHALL MEET LEED REQUIREMENTS & CODE. IN CASE OF CONFLICT, THE HIGHER STANDARD SHALL APPLY. AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION APPROX APPROXIMATE BLDG BUILDING CLG CEILING CONST CONSTRUCTION CW DOMESTIC COLD WATER CXA COMMISSIONING AGENT DEG DEGREES DN DOWN DTL DETAIL DWG(S)DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR ELEC ELECTRICAL EMER EMERGENCY EXIST EXISTING EXT EXTERIOR FD FLOOR DRAIN FS FLOOR SINK F&I FURNISH & INSTALL FLR FLOOR FT FOOT/FEET FCO FLOOR CLEANOUT GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GW GREASE WASTE HR HOUR HVAC HEATING, VENTILATION, AND AIR CONDITIONING HW HOT WATER HS HANDSINK HWS HOT WATER SUPPLY HWR HOT WATER RETURN LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MFG MANUFACTURER MIN MINIMUM MS MOP SINK NL NIGHTLIGHT NTS NOT TO SCALE PC PLUMBING CONTRACTOR PS PREP SINK POC POINT OF CONNECTION REF REFERENCE REQ’D REQUIRED REV REVISION SHT SHEET SF SQUARE FEET SPECS SPECIFICATION(S) SST STAINLESS STEEL TEL TELEPHONE TEMP TEMPORARY TMV TEMPERATURE MIXING VALVE TW TEMPERED HOT WATER TYP TYPICAL UNO UNLESS NOTED OTHERWISE V VENT W SANITARY WASTE WCO WALL CLEANOUT WH WATER HEATER WP WEATHER PROOF WATER PIPING PROVIDE THERMAL INSULATION PER THE SPECIFICATIONS. UNLESS OTHERWISE REQUIRED BY THE LOCAL AUTHORITY OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: PIPE SIZE (DIAMETER) LESS THAN OR EQUAL TO 1 1/2" (38MM) 2" (51MM) OR GREATER (INSULATION VALUE = K VALUE NOT EXCEEDING 0.27 BTU* INCH (H*FT2*F) SAFETY COVERS MEP MECHANICAL, ELECTRICAL, AND PLUMBING SOIL, WASTE, AND VENT PIPING SEE SPECIFICATIONS FOR PIPE MATERIALS. ALL HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4" PER FOOT (21MM PER METER) WHERE POSSIBLE BUT IN NO CASE LESS THAN 1/8" PER FOOT (10MM PER METER) WHERE ALLOWED & SIZED PER AHJ AND CODE. COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR SINKS. PROVIDE PIPED DRAIN (P-TRAP AND VENT) TO SANITARY IF REQUIRED BY LOCAL JURISDICTION. CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDLING UNITS AND STARBUCKS EQUIPMENT (REFER TO SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. HANGERS AND SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS REQUIRED FOR EQUIPMENT AND MATERIAL IN ACCORDANCE WITH SPECIFICATIONS. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS INSTALLED AS REQUIRED BY LOCAL CODES. ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE REQUIRED TO PREVENT SAGGING. CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. CLEANOUTS PROVIDE FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS OR WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. SEE SPECIFICATIONS FOR TYPES. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. INSTALLATION INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" (25MM) OF CLEANING SPACE ALL AROUND PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRE STOPPING SEALANT MATERIAL PER CODE REQUIREMENTS. DO NOT INSTALL PEX PIPING IN RATED WALLS OR THROUGH RATED FLOORS. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND ENSURE PROPER PROTECTION OF PEX PIPING FROM METAL EDGES. UNDERGROUND WATER AND SEWER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL. IDENTIFICATION PROVIDE PIPE IDENTIFICATION EVERY 10 FT (EXCEPT WHERE PIPES ARE EXPOSED TO PUBLIC) IN ACCORDANCE WITH SPECIFICATIONS. INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOF STRAP AS FURNISHED BY STARBUCKS AT ALL EXPOSED ADA SINK P-TRAPS AND WATER SUPPLIES. CWF FILTERED COLD WATER CW HW HWR SAN V STARBUCKS NITROGENATION VENDOR WILL PROVIDE AND INSTALL EQUIPMENT AND FITTINGS, IF APPLICABLE, TO PROJECT SCOPE FOR NITRO STATION. GENERAL CONTRACTOR SHALL COORDINATE NITRO SYSTEM INSTALLATION WITH STARBUCKS VENDOR. P-001 PLUMBING NOTES SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-101GENERAL NOTES A.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PIPE CONDITIONS PRIOR TO NEW CONSTRUCTION, INCLUDING EXACT LOCATION, PRESSURE, PIPE SIZE, AND CAPACITY OF EXISTING SUPPLY LINES. B.PRIOR TO INSTALLATION OF SEWER AND WATER PIPING BELOW GRADE COORDINATE EXACT LOCATIONS AND DEPTHS OF BURIAL WITH CIVIL AND FOUNDATION DRAWINGS AND CORRESPONDING ENGINEERS. C.PRIOR TO DETAILING & INSTALLING PLUMBING AND FIRE PROTECTION PIPING COORDINATE EXACT ROUTING AND ELEVATIONS WITH MECHANICAL, ELECTRICAL AND FIRE SPRINKLER CONTRACTORS. PROVIDE WRITTEN CONFIRMATION THAT THIS COORDINATION HAS BEEN IMPLEMENTED PRIOR TO PROCEEDING WITH INSTALLATION OF PIPING. D.FOR FILTERED WATER EQUIPMENT PROVIDE 1/2" CWF LINE THEN STEP DOWN AT VALVE TO 3/8" OR AS SCHEDULED. E.CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT. IE: ICE MACHINE, ESPRESSO MACHINES, BREWERS, ETC SHALL BE PROVIDED WITH WATTS SD3 TYPE BACKFLOW PREVENTER. ROUTE DRAIN TO FLOOR SINK OR INDIRECT CONNECTION TO SEWER. A. IN THE EVENT THAT THE PITCHER RINSER APPERATUS OUTLET IS BELOW THE FLOOD RIM OF THE SINK IT SERVES, THE FAUCET SERVING IT SHALL BE PROTECTED WITH A BACKFLOW PREVENTER SAME AS NOTED ABOVE. B. WHERE REQUIRED BY THE JURISDICTION, PROVIDE EQUIPMENT WITH A DOUBLE VENTED BACKFLOW PREVENTION DEVICE. F.EACH FAUCET SHALL NOT EXCEED A WATER FLOW OF 1.8 GPM. G.REFER TO SHEET P-001 FOR GENERAL HEALTH CODE REQUIREMENTS AT EQUIPMENT CONNECTIONS. PLUMBING WASTE NOTES 1.SEE PLUMBING SPECIFICATIONS FOR FURTHER REQUIREMENTS. 2.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS. 3.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. 4.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. 5.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. 6.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. 7.WHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO A FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING ALL LINES ABOVE THE DRAIN. 8.FURNISH & INSTALL ALL NEEDED INDIRECT DRAINS PER CODE (NOT ALL SHOWN). INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE WITH AN AIR GAP PER CODE. 9.FURNISH & INSTALL WALL CLEANOUTS AT ALL SINKS AND AS NEEDED AND PER CODE (NOT ALL SHOWN). 10.INSULATE ICE BIN DRAINAGE PIPES PER THE REQUIREMENTS ON THE PLUMBING SPECIFICATION SHEET. PLUMBING PLAN KEYED NOTES 1.CONNECT TO EXISTING GENERAL SANITARY WASTE MAIN NEAR THIS LOCATION. PC SHALL BE RESPONSIBLE TO VERIFY LOCATION, INVERT AND PITCH PRIOR TO BEGINNING WORK. 2.CONNECT TO EXISTING GREASE SANITARY WASTE NEAR THIS LOCATION. PC SHALL BE RESPONSIBLE TO VERIFY LOCATION, INVERT AND PITCH PRIOR TO BEGINNING WORK. SEE BUILDING SHELL PLANS FOR INFORMATION ON EXISTING LANDLORD PROVIDED GREASE INTERCEPTOR. 3.EXISTING SANITARY VENT THRU ROOF NEAR LOCATION SHOWN. VERIFY EXACT LOCATION IN FIELD. 4.3/4" INDIRECT CONDENSATE DRAIN & 3/4" PRESSURE RELIEF VALVE FROM TANK TYPE WATER HEATER TO MOP SINK. TERMINATE WITH AIR GAP. 5.3/4" INDIRECT DRAIN FROM WATER FILTRATION EQUIPMENT TO MOP SINK. TERMINATE WITH AIR GAP. 6.ROUTE INDIRECT DRAIN FROM FOOD SERVICE FIXTURE TO FLOOR SINK, SEE GENERAL NOTE D ON THIS SHEET. 7.3-COMP SINK TO DRAIN INDIRECTLY TO FLOOR SINK, EACH COMPARTMENT SHALL INDEPENDENTLY OF EACH OTHER. 8.ROUTE INDIRECT DRAIN FROM COMBI-OVEN TO FLOOR SINK, WASTE PIPE SHALL BE COPPER TYPE L. 9.1/2" NITROGEN GAS LINE FROM NITROGEN GENERATOR TO NITRO WORKSTATION. FINAL CONNECTION BY STARBUCKS VENDOR. CAFE ENGINE WORKROOM RESTROOM VEST. RESTROOM 1 RESTROOM 2 DRIVE-THRU P-101 PLUMBING WASTE PLAN SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-102 PLUMBING DESIGN PLAN NOTES 1.PLUMBING CONTRACTOR RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE AND OPERATIONAL SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. 2.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. 3.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS. 4.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. 5.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. 6.REFERENCE WORK LETTER FOR DIVISION OF PLUMBING SCOPE OF WORK AND COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER. 7.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. 8.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. 9.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. 10.GENERAL CONTRACTOR SHALL CONTACT WATER FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. GENERAL NOTES A.ALL PLUMBING FIXTURES SHALL BE WATER CONSERVATION TYPE AS MANDATED BY LOCAL BLDG. DEPT. B.PRIOR TO INSTALLATION OF SEWER AND WATER PIPING BELOW GRADE COORDINATE EXACT LOCATIONS AND DEPTHS OF BURIAL WITH EXISTING FOUNDATIONS. C.PRIOR TO DETAILING & INSTALLING PLUMBING AND FIRE PROTECTION PIPING COORDINATE EXACT ROUTING AND ELEVATIONS WITH MECHANICAL, ELECTRICAL AND FIRE SPRINKLER CONTRACTORS. PROVIDE WRITTEN CONFIRMATION THAT THIS COORDINATION HAS BEEN IMPLEMENTED PRIOR TO PROCEEDING WITH INSTALLATION OF PIPING. D.WHETHER SHOWN OR NOT PROVIDE NEW INDIRECT WASTE FROM NEW ICE-CHEST, ICE BIN(S), BAR SINKS WARE RINSER WATER TAP NITRO, ESPRESSO MACHINES, ETC., TO ADJACENT FLOOR SINKS. E.CONTRACTOR SHALL PROVIDE ALL PIPING FROM NEW FIXTURES TO EXISTING WASTE LINES PER MATERIAL REQUIREMENTS ON SHEET P-601. F.MAIN LINE SIZES ARE SHOWN. FOR WASTE AND VENT FIXTURE CONNECTION SIZES REFER TO NEW PLUMBING FIXTURE SCHEDULE OR MATCH ORIGINAL FOR RELOCATED ITEMS. G.BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH STATE AND LOCAL CITY REQUIREMENTS. PLUMBING PLAN KEYED NOTES 1.CONNECT TO EXISTING BACKFLOW PREVENTER BY LANDLORD IN LEASE SPACE AND EXTEND NEW 2" COLD WATER LINE THROUGH SPACE. EXISTING METER ON SITE TO REMAIN. 2.(2) 3/4" COLD WATER WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT TO FILTRATION EQUIPMENT WITH 3/4" FILTERED WATER AND 3/4" COLD SOFTENED WATER OUT. PLUMBING CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ACTIVATION PROCEDURES FOR BOTH SYSTEMS. REFER TO FILTER CONNECTION DETAIL ON SHEET P-501. 3.INSTALL NEW ELECTRIC TANK-TYPE WATER HEATER ABOVE MOP SINK/FILTRATION SYSTEM ON SHELF. SEE DETAILS ON SHEET P-501 FOR ADDITIONAL INFORMATION. 4.PROVIDE THERMOSTATIC MIXING VALVE CONFIRMING TO ASSE 1070 AT HAND SINK, SET DELIVERY TEMP TO 105°F MAX. 5.3/4" COLD FILTERED WATER WITH ASSE 1001 ATMOSPHERIC VACUUM REAKER TO DISHWASHER. INSTALL SHUT-OFF WITH 3/4" MALE HOSE-END FITTING @ 18" AFF UNDER COMPARTMENT SINK. SHUT-OFF TO INCLUDE PRESSURE REDUCING VALVE, PRESSURE GAUGE (SET @ 20 PSIG), LINE STRAINER, AND SHOCK ARRESTOR IN WALL. CONNECT SANITIZER TO CSW SUPPLY WITH 72" LONG BRAIDED STAINLESS STEEL HOSE. 6.3/4" FILTERED WATER TO FOOD SERVICE FIXTURE WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT, EXTEND DISCHARGE PIPING TO NEAREST FLOOR SINK. REDUCE CONNECTION TO 3/8" AT FIXTURE. 7.3/4" FILTERED WATER TO ESPRESSO MACHINE PUMP. CONNECT 3/8" COMPRESSION BRAIDED STAINLESS STEEL HOSE FROM SHUT-OFF TO ESPRESSO MACHINE WATER INLET. SEE DETAIL PROVIDED ON SHEET P-501. 8.3/4" FILTERED AND COLD WATER DOWN IN WALL TO BELOW SLAB. PROVIDE 1/2" ELASTOMETRIC INSULATION ON PIPING BELOW SLAB AND EXTEND 2" ABOVE FINISHED FLOOR. VERIFY ROUTING IN FIELD WITH G.C. PRIOR TO INSTALLATION. 9.ROUTE 3/4" FILTERED AND COLD WATER PIPING THROUGH CABINETRY AND CONNECT TO ITEMS 22642 (2), 11003 (2), 10153(2) & 19742 (2). 10.RECIRCULATION PUMP: BELL & GOSSETT # NBF-9U WET ROTOR-TYPE INLINE PUMP WITH 2800 RPM MOTOR, LEAD-FREE BRONZE BODY WITH UNION CONNECTIONS, CAPACITY OF 1 GPM AT 7 FEET OF HEAD. PROVIDE WITH HONEYWELL #L6006C SURFACE MOUNTED AQUASTAT WITH SINGLE POLE DOUBLE THROW SWITCH FOR CIRCULATOR CONTROL AND ADJUSTABLE DIFFERENTIAL SET TO 10F. SET AQUASTAT TO SHUT OFF RECIRCULATION PUMP AT WATER HEATER SET POINT AND ON AT 10F BELOW SET POINT. SET AQUASTAT TO SHUT OFF RECIRCULATION PUMP AT 3F ABOVE MIXING VALVE SET POINT AND ON AT 7F BELOW SET POINT. ELECTRICAL REQUIREMENTS: 120-VOLT, 0.4 FULL LOAD AMPS. 11.BALANCING VALVE - HAYS "MEASUREFLO", MODEL #2519 COMBINATION AUTOMATIC FLOW CONTROL VALVE AND BALL VALVE, SELF BALANCING, AND FULLY AUTOMATIC WITHOUT ADDITIONAL PIPING OR CONTROL MECHANISMS. SET 3/4" VALVE FOR 0.5 GPM FLOW. 12.PROVIDE COLD WATER CONNECTION TO COMBI-OVEN FOR CLEANING FUNCTION AND FILTERED COLD WATER CONNECTION FOR INJUNCTION FUNCTION. PROVIDE BACKFLOW PREVENTION DEVICE AS REQUIRED BY LOCAL AHJ. CAFE ENGINE WORKROOM RESTROOM VEST.RESTROOM 1 RESTROOM 2 DRIVE-THRU P-102 PLUMBING SUPPLY PLAN SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-401 P-401 PLUMBING ISOMETRICS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-402 P-402 PLUMBING ISOMETRICS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-501 5 ESPRESSO MACHINE GENERAL PIPING CONNECTION SCHEMATIC N.T.S. 3 FLOOR CLEANOUT N.T.S. 1 WALL CLEANOUT N.T.S.2 FLOOR SINK DETAIL N.T.S. 7 UNDERGROUND PIPE SUPPORT N.T.S. WATER HAMMER ARRESTOR N.T.S.4 DOMESTIC COLD WATER FROM WATER SERVICE COLD WATER TO WATER HEATER, SEE WATER HEATER DETAIL ON P-502. STRAP-ON AQUASTAT SET 5 DEGREES LOWER THAN HEATER TEMPERATURE STRAINER RECIRCULATION PUMP RECIRCULATING HOT WATER TO WATER HEATER NOTE: INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS PUMP FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. VACUUM BREAKER BY PC FL O W FLOW FL O W FLOW CHECK VALVE CHECK VALVE HOSE BIBB Scale:NTS6HOT WATER RECIRCULATION PUMP EXPANSION TANK, SEE WATER HEATER DETAIL ON P-502. P-501 PLUMBING DETAILS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-502 3' - 0 " M I N . C L R . (9 1 5 m m ) EQ.EQ. WIRE STORAGE RACK; LOCATE AND INSTALL WALL MOUNT BRACKETS PER MFR INSTRUCTIONS 4 TANK STORAGE WALL BRACKET WITH CHAIN 3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE BEYOND. 1' - 4 " (4 0 5 m m ) 7 1 / 4 " (1 8 5 m m ) 1' - 5 1 / 2 " (4 4 5 m m ) 3'-0" (915mm) STORAGE TANKS BY STARBUCKS VENDOR GAS CYLINDER BRACING2N.T.S. 1' - 0 " (3 0 5 M M ) 2' - 0 " (6 1 0 M M ) 2' - 0 " (6 1 0 M M ) 5' - 7 1 / 2 " (1 7 8 0 M M ) MOP SINK HOT AND COLD WATER SUPPLY FOR MOP FAUCET HOSE CLIP WIRE RACK WATER HEATER STRAP UNITS PER LOCAL CODE REQUIREMENTS MOP HOLDER OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE FRP ENCLOSED CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION. PAN AND DRAIN FOR MAINTENANCE 7 MOP SINK (STACKED) - PLUMBING N.T.S. 3'-3"(915MM) 8' - 9 " ( 2 6 7 0 M M ) A. F . F . NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. POSITION BOOSTER PUMP SO THAT PRESSURE GAUGE IS READABLE AND ACCESSIBLE FOR TROUBLESHOOTING AND MAINTENANCE. 4. BOOSTER PUMP STATIC AND DYNAMIC OUTLET PRESSURE SHALL BE BETWEEN 65 TO 70 PSI. VERIFY PER PUMPS INTEGRAL PRESSURE GAUGE. 5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 6. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. 7. PROVIDE VIBRATION DAMPENING AT BOOSTER PUMP MOUNT TO PLATFORM. WATER HEATER TANK. SEE WATER HEATER TANK DETAIL FOR MORE INFORMATION. GFCI 120V RECEPTACLE FOR BOOSTER PUMP 2" (50MM) MIN. CLEAR CITY WATER IN OUT TO WATER FILTRATION SYSTEM BOOSTER PUMP. SECURE TO SHELF BELOW WITH BOLTS THROUGH BASE PLATE SHELF PER ENGINEER'S DRAWINGS 1 BOOSTER PUMP - PLUMBING N.T.S. 3/4" (20MM) CHROME ESCUTCHEONS (TYP.) 3/4" (20MM) BRASS THREADED BALL SHUT-OFF VALVE (TYP.) MAX 72" (1830MM) A.F.F. UNION (TYP.) 3/4" (20MM) FILTERED COLD WATER TO ICE MACHINE POINT OF USE FILTER LOCATED AT ICE MACHINE MOP SINK NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS). 5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC. 6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER. R.O. PERMEATE TANK 7" (180MM) 9 1/4" (235MM) GFCI 120V QUAD RECEPTACLE FOR FILTER SYSTEM 77" (1955MM) A.F.F. (SEE NOTE 3)FILTERED COLD WATER TO FIXTURES (ESPRESSO MACHINES, BREWERS, HOT TAP, WATER TOWER FAUCET) 75 " (7 9 0 5 M M ) OUT R.O. CONTROL SYSTEM (SEE NOTE 5) 3/4" (20MM) SHUT-OFF VALVE 3/4" (15MM) FIP 3/4" (20MM) SHUT-OFF VALVE 3/4" (20MM) BYPASS 3/4" (20MM) SHUT-OFF VALVE CITY WATER IN TO NON FILTERED FIXTURES (TOILETS, HAND SINKS, DIPPER WELLS, BLENDER PITCHER RINSERS, IN-COUNTER RINSERS, BAR SINKS, HOSE BIBBS) 3/4" (20MM) FIP (FEMALE INTERNATIONAL PIPE THREAD FITTING) (TYP. 1 OF 2 TO SOFTENER) GFCI 120V RECEPTACLE FOR FILTER SYSTEM AT 54" (1372MM) A.F.F. (SEE NOTE 3) IN BRINE TANK (FRONT) WATER SOFTENER HEAD AND TANKS (BEHIND) DRAIN LINE FROM WATER HEATER TANK PAN ABOVE 11" 255MM) 3"(75MM) WATER HEATER TANK SEE WATER HEATER TANK DETAIL FOR MORE INORMATION FROM WATER HEATER TANK TEMPERING VALVE OUT IN IN TO HOT WATER TANK AND ADVANSYS DISHWASHER PLUMBING. SEE WATER HEATER TANK DETAIL FOR MORE INORMATION BYPASS VALVE BLENDED STORAGE TANK ON WALL MOUNTED SHELF 5' - 0 " ( 1 5 2 5 M M ) TO R.O. SYSTEM BOOSTER PUMP BYPASS VALVE 3/4" (20MM) CITY WATER IN BOOSTER PUMP SHUT-OFF VALVE TO BOOSTER PUMP 3/4" (20MM) BOOSTED WATER IN 5' - 9 " ( 1 7 5 0 M M ) WATER FILTRATION BOOSTER PUMP. SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION CONFIGURATION III WATER FILTRATION SYSTEM. SEE CONFIGURATION III, R.O. AND SOFTENER DETAIL FOR MORE INFORMATION. R.O. PERMEATE TANK FRP ENCLOSED 6" ( 1 5 0 M M ) CL E A R 4' - 2 " ( 1 2 7 0 M M ) BA C K E R 2' - 6 " ( 7 6 5 M M ) 7' - 2 " ( 2 1 8 5 M M ) NOTE: 1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION 2' - 0 " ( 6 1 0 M M ) OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE STRAP UNITS PER LOCAL CODE REQUIREMENTS PROVIDE MOISTURE- RESISTANT BLOCKING TO STRUCTURE BEHIND WALL FINISH AT THESE AREAS. REFER TO ITEM SPECIFICATIONS FOR PLUMBING SCOPE; COORDINATE INSTALL WITH FILTER VENDOR. FRP ENCLOSED HOT WATER TANK. SEE SPECIFICATIONS AND WATER HEATER TANK DETAIL FOR MORE INFORMATION. MOP HOLDER 3' - 0 " ( 9 1 5 M M ) 5' - 0 " ( 1 5 2 5 M M ) HOSE CLIP HOT AND COLD WATER SUPPLY FOR FAUCET MOP SINK SEE NOTE 1 BELOW SEE NOTE 1 BELOW 2'-0"(610MM) 6'-0"(1830MM) MIN. BLENDED STORAGE TANK ON WALL MOUNTED SHELF WATER BOOSTER PUMP SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION. FRP ENCLOSED 9' - 6 " ( 2 8 9 5 M M ) T O B O T T O M O F B L E N D E D S T O R A G E T A N K S H E L F 4 CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION 5 CONFIGURATION III N.T.S.N.T.S. EQ EQ 7" EQ EQ 3" DIMENSION DATUM POINT ALL CONDUIT STUB-UPS TO BE WITHIN THIS BOUNDARY 1 CWF STUB-UP 2 CW STUB-UP ESPRESSO BAR PLUMBING STUB-UP KEY 1 2 POS DIEWALL NOTE:SEE SHEET A102 - BUILDING FLOOR PENETRATION PLAN FOR FINAL DIMENSIONED LOCATION. 3- 3 / 4 " 3 PLUMBING STUB-UPS AT ESPRESSO BAR N.T.S. DIRECT DRAIN LINE FROM SINK. ROUGH-IN SINK WASTE STUB AT 15 1/2" (394MM) A.F.F. AND CENTERLINE OF SINK TEMPERED HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (102MM) EITHER SIDE OF WASTE LINE. 7 1/2" 1'-3" CRAFT BAR CASEWORK DETAIL 6 ADD 02-01 PLUMBING N.T.S. P-502 PLUMBING DETAILS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-503 FILTERED COLD WATER SUPPLY FOR ICE MACHINE INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR DRAIN SEE PLUMBING PLAN FOR FINAL FLOOR DRAIN LOCATION AND TYPE .6" (152MM) MIN. CLEAR TO BACK WALL 6" (150MM) MIN. CLEAR . PROVIDE BACKFLOW PREVENTION DEVICE THEN WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION N.T.S.4 ICE MACHINE AND BIN - PLUMBING HOT WATER TANK (SEE SPECIFICATIONS & HOT WATER TANK DETAIL FOR FURTHER INSTALLATION REQUIREMENTS) 1" (25MM) BRASS CHECK VALVE EXPANSION TANK STRAP UNITS PER LOCAL REQUIREMENTS HOT WATER TO DISHWASHER (IF OTHER THAN HOBART ADVANSYS UNIT), BAR SINKS, MOP SINK AND COMPARTMENT SINK. 1" (25MM) HOT WATER OUTLET TEMPERED HOT WATER TO HAND SINKS TEMPERATURE MIXING VALVES UNION (TYP.)CONCEALED COPPER PIPING (TYP.) IF CONFIGURATION II OR III, SOFTENED COLD WATER TO DISHWASHER (IF HOBART ADVANSYS UNIT). SEE NOTE 2 BELOW. OPEN CEILING ABOVE WATER HEATER PER LOCAL CODE PAN AND DRAIN LINE FOR MAINTENANCE BOOSTER PUMP. SEE BOOSTER PUMP DETAIL FOR MORE INFORMATION. FL O W DI R E C T I O N NOTES: 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS DISHWASHER WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. 4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED.. SHELF PER ENGINEER'S DRAWINGS FLOW DIRECTION 5 WATER HEATER TANK - PLUMBING N.T.S. B MOP SINK AND WATER FILTRATION EQUIPMENT. SEE PLAN FOR ACTUAL CONFIGURATION. HOT WATER TANK SUPPORT SHELF PER ENGINEER'S DRAWINGS WATER HEATER TANK PER PLAN HOT WATER TANK CHASE TO ROOF STRUCTURE ABOVE. PAINT GWB FINISH TO MATCH BOH FRP. ROOF STRUCTURE PER PLAN SECTION B 2'-0" CLEAR 7' - 2 " ( M I N . T O B O T O M O F S H E L F ) BOTTOM OF WORKROOM CEILING IN FOREGROND OPEN TO WORKROOM A SECTION A OPTIONAL VCT CEILING. HOLD TIGHT TO STRUCTURE ABOVE HOT WATER PIPING AND FLUE. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED. CE I L I N G H E I G H T P E R P L A N 2" BOOSTER PUMP 3 WATER HEATER TANK CHASE N.T.S. HOT AND COLD WATER FOR SINK FAUCET AT 20 1/2" (520MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE. FILTERED COLD WATER SUPPLY FOR BREWER WITH SHUT-OFF IN CABINET AT 24" (610MM) A.F.F. 7'-6" * 10" FLOOR SINK 2' - 5 1 / 2 " FL O O R S I N K INDIRECT DRAIN LINE FROM BREWER TO FLOOR SINK INDIRECT DRAIN LINE FROM RINSE SINK TO FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE CRAFT BAR CASEWORK DETAIL PROVIDE BACKFLOW PREVENTION DEVICE THEN WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION * 1 BRW 10-01 PLUMBING N.T.S. 2'-6" WORKSTATION TO UTILIZE SAME FLOOR SINK AS ESPRESSO BAR. SEE BUILDING FLOOR PENETRATION PLAN FOR SHARED LOCATION. DRAIN LINES FROM DRAIN TRAY AND UNDERCOUNTER REFRIGERATOR; SEPARATE, INDIRECT TERMINATION AT FLOOR SINK CRAFT BAR CASEWORK DETAIL 2 NIT 12-01 PLUMBING N.T.S. P-503 PLUMBING DETAILS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-504 Plan View KEEP CLEAR FOR WALL MOUNTED CHEMICAL DISPENSING SYSTEM, TO BE INSTALLED BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION. Elevation View SOFTENED HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR DRAIN OR MOP SINK. BACK WALL WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK ARRESTOR. DRAIN LINE FROM SINK TO WASTE LINE IN WALL OR TO FLOOR DRAIN SEE PLUMBING PLAN FOR FINAL FLOOR DRAIN LOCATION. FLOOR DRAIN OPTIONAL. WIRE RACK COMPARTMENT SINK DISHWASHER NOTE: FOR COORDINATION ONLY. SEE FURNITURE, FIXTURES, AND EQUIPMENT PLAN FOR EQUIPMENT LOCATIONS. PROVIDE BACKING BEHIND WALL FINISH AS REQUIRED FOR WALL MOUNTED EQUIPMENT. REFER TO ITEM SPECIFICATIONS FOR MORE INFORMATION. PRE-WASH STATION 4' - 0 " (1 2 2 0 M M ) 1' - 2 " (3 5 5 M M ) 4' - 6 " (1 3 7 0 M M ) DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL ALIGN 3' - 1 1 " (1 1 9 5 M M ) 3' - 2 " (9 6 5 M M ) 11'-4"(3455MM) 3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE BEYOND. 3 1/4" (80MM) 3 SANITIZING (GENERIC) - PLUMBING N.T.S. FILTERED COLD WATER SUPPLY FOR WATER TOWER FAUCET * FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT NON-FILTERED HOT AND COLD WATER SUPPLY FOR SINK FAUCET ABOVE COUNTERTOP AT FLOOR LEVEL INDIRECT LINE FROM PREP SINK ABOVE TO FLOOR SINK SHELVING ABOVE FILTERED COLD WATER SUPPLY FOR UNDERCOUNTER INSTANT HOT WATER BOILER (LOCATION MAY VARY) ** PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* 1 WATER FILLING STATION - PLUMBING N.T.S. 11'-7" ABOVE COUNTER ICE BIN (TYP. 1 OF 2)NON-FILTERED COLD WATER SUPPLY FOR METERED SPOON RINSER (TYP. 1 OF 2) NON-FILTERED COLD WATER SUPPLY FOR PITCHER RINSER (TYP. 1 OF 2) RINSER SINK (TYP. 1 OF 2) 2' - 1 0 1 / 2 " UNDER COUNTER ICE BIN ABOVE WITH INDIRECT AND INSULATED DRAIN LINE TO FLOOR SINK BELOW 7"X3" (180MMX75MM) STUB-UP PENETRATION AREA. SEE BUILDING FLOOR PENETRATION PLAN FOR FINAL LOCATION. INSTALL SHUT-OFF VALVES BETWEEN STUB-UPS AND EQUIPMENT INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK FLOOR SINK (TYP. 1 OF 2) SEE PLUMBING PLAN FOR FINAL LOCATIONS AND TYPE ICE BIN ABOVE WITH INDIRECT AND INSULATED DRAIN LINE TO FLOOR SINK BELOW COUNTERTOP SUPPORT LEG (TYP. 1 OF 3) INDIRECT DRAIN LINE FROM RINSER SINK TO FLOOR SINK UNDERCOUNTER CABINET UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) CRAFT BAR CASEWORK DETAIL UNDERCOUNTER BOILER FOR INSTANT HOT WATER FONT (TYP 1 OF 2) UNDERCOUNTER REFRIGERATOR (TYP. 1 OF 2) 11 1/2"6'-1" INDIRECT DRAIN LINE FROM ESPRESSO MACHINE TO FLOOR SINK FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER FONT (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR WATER TOWER DISPENSER (TYP. 1 OF 2) * FILTERED COLD WATER SUPPLY FOR ESPRESSO MACHINES ** UNDERCOUNTER CABINET FILTERED COLD WATER SUPPLY FOR INSTANT HOT/COLD WATER BOILER (TYP. 1 OF 2) *PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE CONNECTION* **PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE 2 ESP 10-01 PLUMBING N.T.S. P-504 PLUMBING DETAILS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P-505 1 CB WRM PLUMBING N.T.S 2 CB CBE PLUMBING N.T.S INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR DRAIN SEE PLUMBING PLAN FOR FINAL FLOOR DRAIN LOCATION AND TYPE .6" (152MM) MIN. CLEAR TO BACK WALL INDIRECT DRAIN LINE FROM ICE BIN TO FLOOR DRAIN INDIRECT DRAIN LINE FROM ICE DIVERTER TO FLOOR DRAIN ICE MACHINE ICE TRANSPORT TUBE BETWEEN ICE MACHINE AND DIVERTER VALVE. MAX. LENGTH 10' (3M) ICE HEAD ADAPTER ICE MANAGER CONTROL PANEL ICE TRANSPORT TUBE LANE 2, TO ICE BIN. MAX LENGTH 75', MIN. SLOPE 1/4":1' ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1' 3" PVC SLEEVE TO SUPPORT ICE TRANSPORT TUBEFASTENED TO WALL OR CEILING W/ STRAPING @ 48" O.C. MIN. ICE DIVERTER VALVE ELEVATION - PLUMBING DIAGRAM PLAN - PLUMBING DIAGRAM CONT. FRP TO CEILING ON BACK WALL OVER IN WALL BLOCKING ICE BIN ICE MACHINE ICE HEAD ADAPTER NOTE: INDIRECT DRAIN MIN. RADIUS = 8" ICE TRANSPORT TUB MIN. RADIUS = 6" NOTE: INDIRECT DRAIN MIN. RADIUS = 8" ICE TRANSPORT TUB MIN. RADIUS = 6" ECO-GRIP COVER BASE ACCESSIBLE CLEARANCE AT CONTROL PANEL ICE MANAGER CONTROL PANEL ICE DIVERTER VALVE CONT. FRP ON BACK WALL OVER IN WALL BLOCKING BACK WALL r6 MIN. BIN TOP SENSOR DISTRIBUTION UNIT ICE BIN INDIRECT DRAIN LINE FROM ICE MACHINE TO FLOOR DRAIN 48 30 Scale: 3/4" = 1'-0"3 PLUMBING - NUGGET ICE - PEDESTAL STACK 78 FLOOR DRAIN ELEVATION - PLUMBING DIAGRAM FILTERED WATER SUPPLY FOR COMBI OVEN WATER INJECTION WITH SHUT-OFF IN CABINET AT 18" (457MM) A.F.F. COLD WATER SUPPLY FOR COMBI OVEN CLEANING WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. COLD WATER SUPPLY FOR COMBI OVEN CLEANING WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. FILTERED WATER SUPPLY FOR COMBI OVEN WATER INJECTION WITH SHUT- OFF IN CABINET AT 18" (457MM) A.F.F. INDIRECT DRAIN LINE FROM COMBI OVEN TO FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE PLAN - PLUMBING DIAGRAM IN-WALL INDIRECT DRAIN LINE FROM ICE DISPENSER TO FLOOR DRAIN OUTLET BOX FOR INDIRECT DRAIN LINE FLOOR DRAIN SOFFIT OUTLET BOX FOR INDIRECT DRAIN LINE FLOOR DRAIN OUTLET BOX FOR INDIRECT DRAIN LINE 12 55 1 / 2 CEILING OUTLET BOX FOR INDIRECT DRAIN LINE ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1'. CONTINUOUS CONDUIT FASTENED W/ STRAPING @ 48" O.C. MIN. CEILING IN-WALL INDIRECT DRAIN LINE FROM ICE DISPENSER TO FLOOR DRAIN SOFFIT INDIRECT LINE FROM DRAINBOARD TO FLOOR SINK HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET AT 20 1/2" (20MM) A.F.F. SHUT-OFF VALVES AT WALL AND 4" (100MM) EITHER SIDE OF WASTE LINE NON-FILTERED COLD WATER SUPPLY FOR BLENDER PITCHER RINSER INDIRECT DRAIN LINE FROM SINK TO FLOOR SINK FILTERED COLD WATER SUPPLY FOR WATER TOWER FAUCET DRAIN LINES FROM DRAIN TRAY AND UNDERCOUNTER REFRIGERATOR; SEPARATE, INDIRECT TERMINATION AT FLOOR SINK SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION AND TYPE ELEVATION - PLUMBING DIAGRAM SECTION A - PLUMBING DIAGRAM ACCESS PANEL/DOOR DOOR FACE W/ TAPERED EDGE PULL MOUNTING TEMPLATE, BLACK IN-WALL BLOCKING REQUIRED, PROVIDED BY G.C. FRAMING, BLACK ACCESS DOOR ICE TRANSPORT TUBE LANE 1, TO ICE DISPENSER. MAX LENGTH 75', MIN. SLOPE 1/4":1' CONTINUOUS CONDUIT FASTENED W/ STRAPING @ 48" O.C. MIN. A VA R I E S 138 6 6 EQ EQ P-505 PLUMBING DETAILS SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description P601 NEW EQUIPMENT NOTES: 1.CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL ACCESSORIES, FITTINGS, VALVES, ETC. AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. ALL ITEMS MAY NOT BE SHOWN OR REFERENCED. 2.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LAYOUTS, ELEVATIONS, FINISHES, ETC. 3.SEE PLANS FOR WASTE CONNECTION TYPE, EITHER DIRECT OR INDIRECT PER PLAN NOTES. 4.IND = INDIRECT TYPE WASTE CONNECTION. P-601 PLUMBING SCHEDULES SHEET NUMBER: SHEET TITLE: SCALE: AS SHOWN STORE #: PROJECT #: PR O J E C T N A M E : PR O J E C T A D D R E S S : C 2023 STARBUCKS COFFEE COMPANY R ISSUE DATE: 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 ARCHITECT OF RECORD THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. THESE DRAWINGS AND THE PROJECT MANUAL ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION: i2023.01.30 STARBUCKS R DESIGN MANAGER: PRODUCTION DESIGNER: CHECKED BY: 102442-001 05-01-2024 YE L M & K I L L I O N 14 0 6 E Y E L M A V E , YE L M , W A 9 8 5 9 7 84311 NJF JEM WHS Revision Schedule Rev Date By Description