SB84311_Yelm & Killion_Permit Set_Building1.THE DRAWINGS AND PROJECT MANUAL TOGETHER CONSTITUTE THE
CONTRACT DOCUMENTS FOR CONSTRUCTION. ALL GENERAL
REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND
SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS
UNLESS OTHERWISE NOTED.
2.GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING
SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS
AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS
PRIOR TO CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS
CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS
OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION.
4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH
LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES.
5.GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL
UTILITIES.
6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING
CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE
OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL
DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT
SCALE DRAWINGS.
7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING
WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO
REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE
WORK.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING
PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS.
9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS
ON-SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION.
THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AT
PROJECT CLOSE-OUT AS DESCRIBED IN THE GENERAL
REQUIREMENTS OF THE PROJECT MANUAL.
10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING
DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD
PARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECT
SHIPMENTS. SEE THE PROJECT MANUAL FOR ADDITIONAL
INFORMATION.
11.RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND
EQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETS
UNDER THE COLUMN LABELED "RESPONSIBILITY".
12. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN
TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE,
BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS
AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL
INSTALLATION, UNLESS OTHERWISE NOTED.
13.ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS
CONSTRUCTION MANAGER.
GENERAL NOTESPROJECT CONTACTS
MAILING
ADDRESS:
DESIGN
MANAGER:
ALINA PINCHUK
GRAPHITE DESIGN GROUP
1809 7TH AVE STE 700
SEATTLE, WA 98101
(206) 519-5138
STARBUCKS COFFEE COMPANY
2401 UTAH AVENUE SOUTH
MS STOP: S-SD10
SEATTLE, WASHINGTON 98134
(206) 318-1575
CONSTRUCTION
MANAGER:
CHERYL PARROTT
2401 UTAH AVE S
MS STOP: S-SD10
SEATTLE, WA 98124
(206) 618-8361
LANDLORD:JOHN WALKER
URBAN OLYMPIC
PO BOX 7534
OLYMPIA, WA 98507
ARCHITECT
OF RECORD:
GRAPHITE DESIGN GROUP
1809 7TH AVE STE 700
SEATTLE, WA 98101
(206) 224-3335
MEP
CONSULTANT
OF RECORD:
WHS ENGINEERING, INC
2012 WEST 25TH ST, #200
CLEVELAND, OH 44113
INDEX OF SHEETS
LEGEND:X - SHEET ISSUED
R - SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY
SEE TITLEBLOCK FOR REVISION ISSUE DATE(S)
SCOPE OF WORK
TENANT IMPROVEMENT OF A FIRST-TIME BUILD-OUT OF AN INTERIOR
SPACE IN A NEW MULTI-TENANT SINGLE-LEVEL BUILDING WITH DRIVE-
THRU FOR A COFFEE SHOP. WORK INCLUDES: NON-STRUCTURAL
PARTITIONS, INTERIOR DOORS, SUSPENDED CEILINGS, LIGHTING,
FINISHES, FURNIUTURE/CASEWORK/FOOD SERVICE EQUIPMENT
INSTALLATION, ASSOCIATED
MECHANICAL/PLUMBING/ELECTRICAL/GAS/TELECOMMUNICATION
SYSTEMS.
ALL EXTERIOR SIGNAGE TO BE UNDER SEPERATE PERMIT.
CODE AUTHORITIES:
BUILDING CODE:2021 INTERNATIONAL BUILDING CODE W/
WAC AMENDMENTS
PLUMBING CODE:2021 UNIFORM PLUMBING CODE W/ WAC
AMENDMENTS
MECHANICAL CODE:2021 INTERNATIONAL MECHANICAL
CODE W/ WAC AMENDMENTS
ELECTRICAL CODE:2023 NATIONAL ELECTRICAL CODE (NEC)
ENERGY CODE:2021 WASHINGTON STATE ENERGY
CODE
FIRE CODE:2021 INTERNATIONAL FIRE CODE W/
WAC AMENDMENTS
HEALTH CODE:WASHINGTON STATE RETAIL FOOD
CODE CHAPTER 246-215 (WAC)
ACCESSIBILITY CODE:2017 ICC/ANSI A117.1 W/ WAC
AMENDMENTS
ZONING:
PARCEL NUMBER:45170000400, 451700000010
LEASABLE AREA:2,300 SQ FT
ZONING TYPE:C-1
PROPOSED USE:RETAIL ESTABLISHMENTS
DEFERRED SUBMITTALS:SIGNAGE
SITE INFORMATION
VICINITY PLAN
AERIAL MAP
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AMP AMPERE
ARCH ARCHITECT
BOH BACK OF HOUSE
CAB CABINET
CL CENTER LINE
CLG CEILING
CM STARBUCKS
CONSTRUCTION MANAGER
CTR CENTER
CX COMMISSIONING
CXA COMMISSIONING AGENT
DEG DEGREE
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DM STARBUCKS
DESIGN MANAGER
DN DOWN
EA EACH
EL ELEVATION
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FF&E FURNITURE,
FIXTURE, AND EQUIPMENT
FLR FLOOR
FOH FRONT OF HOUSE
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER
INSTALLED BY OWNER
FT FOOT/FEET
G GROUND
GC GENERAL CONTRACTOR
GWB GYPSUM WALLBOARD
HC HOLLOW CORE
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATING
AND AIR CONDITIONING
I.D.INSIDE DIAMETER
LEED LEADERSHIP IN ENERGY
AND ENVIRONMENTAL DESIGN
LL LANDLORD
LV LOW VOLTAGE
MAX MAXIMUM
MEP "MECHANICAL, ELECTRICAL
AND PLUMBING"
MFR MANUFACTURER
MIN MINIMUM
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OC ON CENTER
O.D.OUTSIDE DIAMETER
PIR PASSIVE INFRARED SENSOR
PLC PLACE
R RADIUS
REF REFERENCE
REQ‘D REQUIRED
REV REVISION
RND ROUND
SB STARBUCKS
SC SOLID CORE
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
TEMP TEMPORARY
TYP TYPICAL
UC UNDER COUNTER
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
ABBREVIATIONS
X' XX"
X
N
NORTH
ARROW
XXXX AFF
ARCHITECTURAL SYMBOL LEGEND
XXXXXW
XX
Scale: X =X
0 2 4 8
GRAPHIC
SCALE
DATUM
POINT
EXTERIOR
ELEVATION
CALL-OUT
INTERIOR
ELEVATION
CALL-OUT
SECTION
CALL-OUT
DETAIL
CALL-OUT
REVISION
TAG
PAINT
TAG
DESIGN ID
TAG
DOOR
TAG
WINDOW
TAG
SHEET
NOTE
CALLOUT
ABOVE FINISH
FLOOR
HEIGHT TAG
FINISH FACE TO
FINISH FACE
DIMENSION
REVISION
CLOUD
PT XXXXX XXXXXX XXXXXD XX
INTERIOR
WALL TAG
GC
LL
SB
SV
RESPONSIBILITY
LEGEND
GENERAL CONTRACTOR
LANDLORD
STARBUCKS
SIGNAGE VENDOR
OCCUPANCY TYPE:B (BUSINESS)
BUILDING AREA:6,300 SQ FT.
TENANT AREA:2,300 SQ FT.
CONSTRUCTION TYPE:V-B
FIRE SPRINKLER:YES
BUILDING INFORMATION
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
G001
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
GENERAL INFORMATION
SHEET SHEET TITLE P
E
R
M
I
T
S
E
T
R
E
V
I
S
I
O
N
1
R
E
V
I
S
I
O
N
2
R
E
V
I
S
I
O
N
3
R
E
V
I
S
I
O
N
4
GENERAL
G001 GENERAL INFORMATION X
G002 LIFE SAFETY AND ACCESSIBILITY PLAN X
G003 RENDERINGS - EXTERIOR R
G004 RENDERINGS - INTERIOR R
ARCHITECTURAL
A001 ARCHITECTURAL SITE PLAN X
A002 ENLARGED SITE PLANS X
A003 SITE DETAILS X
A004 SITE DETAILS X
A005 SITE DETAILS X
A101 BUILDING FLOOR PLAN X
A102 BUILDING FLOOR PENETRATION PLAN X
A201 BUILDING EXTERIOR ELEVATIONS X
A501 BUILDING DETAILS X
A601 WINDOW AND DOOR SCHEDULES & DETAILS X
INTERIORS
I101 FF & E PLAN X
I102 ENLARGED FF & E PLAN X
I103 CASEWORK PLAN X
I104 REFLECTED CEILING PLAN X
I105 FLOOR FINISH PLAN X
I106 WALL FINISH PLAN X
I201 INTERIOR FINISH ELEVATIONS X
I202 INTERIOR FINISH ELEVATIONS X
I203 INTERIOR FINISH ELEVATIONS X
I401 RESTROOM PLAN & ELEVATIONS X
I501 INTERIOR DETAILS - FLOOR X
I502 INTERIOR DETAILS - WALL X
I503 INTERIOR DETAILS - WALL/CEILING X
I504 INTERIOR DETAILS - WALL/CEILING X
I505 INTERIOR DETAILS - SUSPENDED CEILING X
I506 INTERIOR DETAILS - MENU BOARDS X
I601 INTERIOR FINISHES & CASEWORK SCHEDULES X
I602 FF&E SCHEDULES X
I603 PLUMBING & LIGHTING SCHEDULES X
ELECTRICAL
E001 ELECTRICAL NOTES X
E002 ELECTRICAL NOTES X
E003 ELECTRICAL ENERGY COMPLIANCE X
E006 SITE ELECTRICAL PLAN X
E101 POWER PLAN X
E102 LIGHTING PLAN X
E103 LOW VOLTAGE DESIGN PLAN X
E501 ELECTRICAL DETAILS X
E502 ELECTRICAL DETAILS X
E503 ELECTRICAL EMS DETAILS X
E601 PANELBOARD SCHEDULES X
MECHANICAL
M001 MECHANICAL NOTES X
M101 MECHANICAL PLAN X
M102 MECHANICAL ROOFTOP PLAN X
M601 MECHANICAL SCHEDULES X
PLUMBING
P001 PLUMBING NOTES X
P101 PLUMBING WASTE PLAN X
P102 PLUMBING SUPPLY PLAN X
P401 PLUMBING ISOMETRICS X
P402 PLUMBING ISOMETRICS X
P501 PLUMBING DETAILS X
P601 PLUMBING SCHEDULES X
Revision Schedule
Rev Date By Description
N
N
A.
B.
C.
D.
E.
F.
G.
H.
EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL
HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A
CONSPICUOUS PLACE, NEAR THE MAIN EXIT ACCESS DOORWAY.
POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT
DESIGN AND SHALL BE MAINTAINED BY THE OWNER AUTHORIZED
AGENT. (1004.9 IBC)
EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS,
CLOSETS OR SIMILAR SPACES. (1016.2 IBC)
PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN
THIS BUILDING SHALL SATISFY THE FOLLOWING (1010.2.9 IBC):
1)THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL
EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH.
2)THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15
POUNDS (6.8 KG).
3)PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD
TYPE WHERE PANIC HARDWARE IS REQUIRED AND THE PAD
SHALL NOT EXTEND ACROSS MORE THAN ONE-HALF OF THE
DOOR WIDTH, MEASURED FROM THE LATCH SIDE.
4)PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305.
5)FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C
AND UL 305.
STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT
PROJECT HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES
(100 MM) OVER ANY WALKING SURFACE BETWEEN 27 INCHES (685
MM) AND 80 INCHES (2030 MM) ABOVE THE WALKING SURFACE.
EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE
PERMITTED TO PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL.
(1003.3.3)
THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS
BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO
THE REQUIREMENTS OF SECTION 1011 AND AS NOTED BELOW:
1)EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION
OF EGRESS TRAVEL.
2)EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY
INDICATE THE DIRECTION OF EGRESS TRAVEL.
3)NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M)
OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER
IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN.
WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN
ON OR ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH
(25 MM) LETTERING STATING THAT "THIS DOOR TO REMAIN
UNLOCKED WHEN BUILDING IS OCCUPIED". (1010.2.4.3.2 IBC)
EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE
EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE
OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER
OPERATING DEVICES SHALL BE INSTALLED 34 INCHES (860 MM) TO
48 INCHES (1220 MM) ABOVE FINISHED FLOOR. MANUALLY
OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT
PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT
REQUIRE MORE THAN ONE OPERATION. (1010.2, 1010.2.3, 1010.2.5
IBC)
LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND
SUCH LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE
OF THE DOOR LANDINGS SHALL HAVE A WIDTH NOT LESS THAN
THE WIDTH OF THE DOOR AND LENGTH MEASURED IN THE
DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (11120 MM).
(1010.1.4, 1010.1.5 IBC)
MEANS OF EGRESS NOTES
1.THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL
APPLICABLE CODES.
2.BARRIER-FREE PATH OF TRAVEL.
3.30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS.
4.67" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR
ACCESS.
5.32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR.
6.POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF
PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR
WHEELCHAIR ACCESSIBILITY.
7.PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS
PER ALL APPLICABLE CODES.
8.PROVIDE TACTILE "EXIT" SIGNAGE.
9.PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE
REQUIRED BY APPLICABLE LAWS OR CODES
10.PREP SINK.
11.WORK SINK.
12.HAND SINK.
13.3-COMP SINK.
14.MOP SINK.
15.RINSE SINK.
16.DISHWASHER.
17.HOT WATER HEATER.
18.WATER FILTRATION.
KEYED NOTES
LEGEND
PATH OF TRAVEL
EMERGENCY LIGHT
BARRIER FREE PATH OF TRAVEL
(MIN 3'-0" - NO PINCH POINT)
EXIT SIGN
FIRE EXTINGUISHER
ADA ACCESSIBLE SEATING
30" (915MM) X 48" (1220MM) CLEAR AREA
COMMON PATH OF TRAVEL
FE
BAR
FLOOR:POLYVINYL FLOORING
WALL:WALL TILE, BACKSPLASH, WITH POLYVINYL BASE
CEILING:GYPSUM CEILING
CAFE
FLOOR:POLISHED CONCRETE
WALL:WOOD PANELS, GYPSUM, WITH TILE BASE
CEILING:GYPSUM, WOOD GRILLE SYSTEM
WORKROOM
FLOOR:POLYVINYL FLOORING
WALL:FRP WITH POLYVINYL BASE
CEILING:ACOUSTICAL CEILING TILE
RESTROOM
FLOOR:POLISHED CONCRETE
WALL:PARTIAL HEIGHT TILE, GYPSUM, WITH TILE BASE
CEILING:GYPSUM CEILING
HEALTH DEPT. FINISH SCHEDULE
A.GENERAL CONTRACTOR TO SCHEDULE WITH
REFRIGERATION CONTRACTOR TO CONDUCT INITIAL
FOOD CASE START-UP AND TESTING. FOR APPROVED
CONTRACTOR, CONTACT THE VENDOR.
B.THE SPACE IS SERVED BY THE MUNICIPAL WATER AND
SEWER SYSTEM UNLESS OTHERWISE NOTED.
C.ALL EQUIPMENT AND INSTALLATION WILL MEET
NATIONAL SANITATION FOUNDATION STANDARDS OR
EQUIVALENT.
D.EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED
THREADS, EMBELLISHMENTS OR OVERHANGING EDGES
THAT SERVE AS PLACES FOR ACCUMULATION OF DUST,
DIRT AND DEBRIS
E.WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES.
INSTALLATION AT STORE OPENING TO BE VERIFIED BY
STARBUCKS CONSTRUCTION REPRESENTATIVE.
F.EACH HAND WASHING WILL HAVE A SINGLE SERVICE
TOWEL AND SOAP DISPENSER AND ALL HAND SINKS TO
HAVE A COMBINATION FAUCET OR PREMIXING FAUCET.
G.REFERENCE INTERIOR SCHEDULE SHEETS (I600 SERIES)
FOR ADDITIONAL INFORMATION.
H.PROVIDE SNEEZE GUARDS WHERE REQUIRED BY
JURISDICTION.
I.ALL FOOD STORAGE AND DISPLAY SHELVING SHALL BE A
MINIMUM 6" (150MM) ABOVE FINISH FLOOR.
HEALTH DEPT. PLAN NOTES
71' -
1
0
3
/
4
"
35' - 7 1/4"
2"
PATH OF TRAVEL 2
15'-6"
859 SF
CAFE
540 SF
ENGINE
463 SF
WORKROOM
548 SF
PATIO
52 SF
RESTROOM
VEST.48 SF
RESTROOM 1
57 SF
RESTROOM 2
GREATEST PATH OF TRAVEL 104'-8"
PATH OF TRAVEL 1
33'-5"
COMMON PATH OF TRAVEL
45'-8"
POINT OF GREATEST REMOTENESSCOMMON PATH OF TRAVEL
11'-11"
1
1
2
4
3
4
4
5
5
6
7
79 9
10
11
13
12
141817
16
15
4
4
REQD PROV
15"
74 OCC
69"
EXIT TO GRADE
REQD PROV
15"
74 OCC
33"
EXIT TO GRADE
COMMON PATH OF TRAVEL
71'-3"
8
8
6
16
3
81 SF
DRIVE-THRU
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
G002
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
LIFE SAFETY AND
ACCESSIBILITY PLAN
**RETAIL ESTABLISHMENT SERVES WATER UPON REQUEST.
*IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67% OF THE
REQUIRED WATER CLOSETS IN ASSEMBLY OCCUPANCIES.
PROVIDED 2 UNISEX 0 M 2 UNISEX 0
REQUIRED 1 M 1 F 0 M 1 M 1 F 0
1 PER 25 FOR FIRST 50 AND 1 PER
50 FOR REMAINDER EXCEEDING
50
1 PER 40 FOR FIRST
80 AND 1 PER 80 FOR
REMAINDER
EXCEEDING 80
1 PER 100 OR STATIONFIXTURES
WATER CLOSETS URINALS*LAVATORY WATER FOUNTAIN**
32 OCC.33 OCC.65 OCC.OCCUPANCY MALE FEMALE TOTAL
CHAPTER29-2021 IBC TABLE 2902.1
PLUMBING FIXTURE CALCULATIONS
EXIT SEPARATION PROVIDED = 35' - 7 1/4"
MINIMUM. EXIT SEPARATION = 71' - 11 3/4" (MAXIMUM DIAGONAL) / 3 = 23' - 11 7/8"
MAXIMUM. TRAVEL DISTANCE PROVIDED = 104' - 8"
MAXIMUM. ALLOWABLE TRAVEL DISTANCE= 250' - 0"
NUMBER OF EXITS PROVIDED = 2
NUMBER OF EXITS REQUIRED = 2
EXITS = 69 IN. PRIMARY ENTRY, 33 IN. SECONDARY ENTRY
EXIT WIDTH PROVIDED = 102 IN.
EXIT WIDTH REQUIRED - 74 OCC. x 0.2 = 15 IN.
EGRESS CALCULATIONS
Scale: 1/4" = 1'-0"1 LIFE SAFETY PLAN
N
Revision Schedule
Rev Date By Description
OCCUPANCY CALCULATIONS (EXTERIOR)
NAME AREA CLASSIFICATION
LOAD
FACTOR
(PER /SF)OCCUPANTS
EXTERIOR
PATIO 548 SF UNCOCENTRATED
TABLES AND CHAIRS
15 37
EXTERIOR 548 SF 37
TOTAL
OCCUPANTS
COMBINED:
548 SF 37
OCCUPANCY CALCULATIONS (INTERIOR)
NAME AREA CLASSIFICATION
LOAD
FACTOR
(PER /SF)OCCUPANTS
INTERIOR
CAFE 859 SF UNCOCENTRATED
TABLES AND CHAIRS
15 58
DRIVE-THRU 81 SF COMMERCIAL
KITCHEN
200 1
ENGINE 540 SF COMMERCIAL
KITCHEN
200 3
RESTROOM 1 48 SF ACCESSORY 0 0
RESTROOM 2 57 SF ACCESSORY 0 0
RESTROOM
VEST.
52 SF ACCESSORY 0 0
WORKROOM 463 SF COMMERCIAL
KITCHEN
200 3
INTERIOR 2100 SF 65
TOTAL
OCCUPANTS
COMBINED:
2100 SF 65
OCCUPANCY (FIXED SEATING)
NAME LENGTH CLASSIFICATION
LOAD
FACTOR
(OCC/LF)OCCUPANTS
INTERIOR
FIXED
SEATING
16' - 6"ASSEMBLY
CONCENTRATED
2' - 0"9
16' - 6"9
TOTAL
OCCUPANTS
(FIXED
SEATING)
16' - 6"9
EXIT ACCESS DISTANCE
00 Common Path of Travel 4 71' - 3"
00 Common Path of Travel 5 45' - 8"
00 Common Path of Travel 6 11' - 11"
00 Common Path of Travel 128' - 11"
00 Exit Access Travel 1 33' - 5"
00 Exit Access Travel 2 15' - 6"
00 Exit Access Travel 49' - 0"
TOTAL ACCESSIBLE SEAT (≥5%)2
TOTAL 27
SOFT SEATING 7 7
TABLE TOPS AT BANQUETTE 5 10
TABLE TOP, SQUARE 5 10
DESCRIPTION NUMBER OF ITEMS SEATS
INDOOR SEATING CALCULATIONS
TOTAL ACCESSIBLE SEATS ( ≥ 5% )1
TOTAL 16
TABLE TOP, ROUND 2 8
TABLE TOP, RECTANGLE 2 8
DESCRIPTION NUMBER OF ITEMS SEATS
OUTDOOR SEATING CALCULATIONS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
G003
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
RENDERINGS -
EXTERIOR
Revision Schedule
Rev Date By DescriptionNOTE:
RENDERINGS ARE FOR
ILLUSTRATION PURPOSES
ONLY, FOR ANY
DISCEPENCIES CD DRAWINGS
SUPERSEDE
VIEW OF DRIVE-THRU ORDER POINT VIEW OF EXTERIOR MURAL AND DRIVE-THRU
VIEW OF BUILDING ENTRANCE AND PATIO VIEW OF DRIVE-THRU ENTRY
VIEW OF DRIVE-THRU APPROACHVIEW OF BUILDING ENTRANCE, PARKING, AND DRIVE-THRU EXIT
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
G004
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
RENDERINGS -
INTERIOR
Revision Schedule
Rev Date By Description
NOTE:
RENDERINGS ARE FOR ILLUSTRATION PURPOSES ONLY,
FOR ANY DISCEPENCIES CD DRAWINGS SUPERSEDE
VIEW OF CAFE ENTRY VIEW OF CAFE
VIEW OF ENGINE VIEW OF RESTROOM VESTIBULE
1.LANDSCAPE AREA BY LL.
2.ACCESSIBLE PATH OF TRAVEL.
3. 6” CONCRETE CURB BY LL, TYPICAL.
4.CANOPY (ABOVE) BY LL.
5.MURAL UPLIGHTING PROVIDED BY LL.
6.PEDESTRIAN PATH BY LL TO TRASH ENCLOSURE.
7.COVERED TRASH ENCLOSURE CONCRETE APRON BY
LL.
8.DT DIRECTIONAL ARROW SIGN, FOOTING BY LL.
9.WAYFINDING PAVEMENT GRAPHICS LL.
10.LOCATION OF MOP CUSTOMER PARKING SIGNAGE.
11. ADA PARKING SIGNAGE AND GROUND GRAPHICS BY
LL.
12.APPROXIMATE LOCATION OF UNDERGROUND
GREASE INTERCEPTOR BY LL. SEE LL PLUMBING
PLANS.
A.REFER TO EXTERIOR ELEVATIONS ON SHEET A201
FOR BUILDING SIGNAGE LOCATION AND DESIGN ID.
REFER TO ELECTRICAL PLANS FOR ELECTRICAL
REQUIREMENTS.
B. LANDSCAPING BY LL TO BE PROVIDED PER ZONING
CODE AND SUSTAINABILITY REQUIREMENTS.
C. DRIVE-THRU EQUIPMENT INCLUDING VEHICLE
DETECTION LOOP, WIRELESS COMMUNICATION AND
MONITORS SHALL BE COORDINATED BY STARBUCKS
CONSTRUCTION MANAGER AND INSTALLED BY LL.
REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
D. LL TO PROVIDE 6" (150MM) THICK CONCRETE
PAVING THE LENGTH OF THE DRIVE-THRU LANE,
EXTENT TO INCLUDE DRIVE-THRU ENTRY POINT
THROUGH WINDOW STANDING PAD.
E. LANDLORD TO APPLY CONCRETE
SEALER TO ALL EXTERIOR CONCRETE PATIO AND
WALKWAY SURFACES.
F.GENERAL CONTRACTOR TO VERIFY ALL EXISTING
ELEVATIONS AND BUILDING CONDITIONS IN FIELD
PRIOR TO START OF CONSTRUCTION.
G.LANDLORD TO PROVIDE DETECTABLE WARNING (IF
APPLICABLE PER LOCAL CODE) AT TRANSITION FROM
SIDEWALK TO DRIVE AISLE.
H.ACCESSIBLE PARKING SPACES AND ACCESS AISLES
SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN
ALL DIRECTIONS.
I.REFER TO LANDLORD ELECTRICAL DRAWINGS FOR
SITE RELATED ELECTRICAL WORK.
J.SEE SHEET A003-5 FOR ARCHITECTURAL SITE
DETAILS.
KEYED NOTES
GENERAL NOTES
LANDSCAPE AREA BY LL
LEGEND
NEW 6" (150MM) CONCRETE CURB BY LL
NEW CONCRETE WALKWAY BY LL
CONCRETE DRIVE THRU LANE BY LL
ACCESSIBLE PATH OF TRAVEL
NEIGHBORING
TENANTS
4,000 SF
YE
L
M
A
V
E
N
U
E
S
E
STARBUCKS
2,295 SF
A002
1
A002
3
A002
2
Y 2311323113 9
Y 2311323113 9
9' - 2"
7'
-
1
1
3
/
4
"
15' - 10 1/4"
25
'
-
1
1
"
Y 2311923119 9
6' - 2 1/4"
1'
-
4
1
/
4
"
Y 2311923119
Y 2311723117 9
8' -
1
3
/
4
"
7' -
6
1
/
4
"
9
16'
-
7
1
/
2
"
Y 2311923119
Y 2311923119
9
9
7
S 212972129710
1
1
1
A003
10
A003
10
3
3
3
4 4
4
6
8
S 23733237338
11
11
S 2310523105
4
4
2
5
12
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A001
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
ARCHITECTURAL SITE
PLAN
SITE SCHEDULE - "Y"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
EXTERIOR MENU
22540 1 MENU BOARD - DT 5 PANEL SQUARE FRAME
FREESTANDING - 95X62IN 2415X1575MM -
BLACK
SB SV SUPPLIER: DT SIGNAGE VENDOR (DSA) INSTALLER:
REGIONAL SIGNAGE VENDOR
22542 1 MENU BOARD - DT PRE MENU SQUARE
FRAME FREESTANDING - 29X61IN
735X1550MM - BLACK
SB SV SUPPLIER: DT SIGNAGE VENDOR (DSA) INSTALLER:
REGIONAL SIGNAGE VENDOR
22546 1 MENU BOARD - DT DIGITAL ORDER SCREEN
WITH POST - BLACK
SB SV SUPPLIER: IT EQUIPMENT VENDOR (ZONES) SCREEN
INSTALLER: REGIONAL SIGNAGE VENDOR ELECTRICAL: GC
CONNECTS DOS WHIPS & STUB-UPS TO DCB: (NCR) - LOW
VOLTAGE
FENCE AND RAILING
21486 13 FENCE MESH - 54IN 1370MM LL LL
OTHER
10020 1 DT WINDOW SHELF - 48IN 1205MM - SST LL LL
22543 1 DT ORDER POINT CANOPY SQUARE FRAME -
BLACK
SB SV
23113 3 GROUND GRAPHICS DT ENTRY STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE
23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE
23117 15 GROUND GRAPHICS ARROW STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE
23119 5 GROUND GRAPHICS STOP STENCIL LL LL TRAFFIC PAINT SPEC: TTP = 1952E TYPE III, WHITE
X1115 4 CONCRETE BOLLARD, FOOTING BY LL GC GC
UMBRELLA
12147 3 UMBRELLA - BASE 95LB 43KG - FLAT BLACK
MT0028
SB SB
20073 3 UMBRELLA - WITHOUT VALANCE - 6FT 183CM
- GREEN CANVAS WITH WORDMARK F0056
SB SB
SIGNAGE SCHEDULE - "S"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS
SIGNAGE - DISK
22606 3 SIGN - DISK SF ILLUMINATED FLUSH
MOUNTED EVOLVED - 72IN 1830MM
SB GC
SIGNAGE - DRIVE THRU
22544 1 SIGN - DT CLEARANCE BAR SQUARE FRAME
FREESTANDING - BLACK AND DARK GREEN
SB GC
23074 1 part SIGN DIR EXIT ONLY ILLUM DS EXG FDN -
44IN
SB GC
23105 1 SIGN - DT DIRECTIONAL SIREN WITH ARROW
ILLUM DS - NEW FOUNDATION - 44IN 1120MM
SB GC
23733 1 SIGN - DT DIRECTIONAL SIREN NON-ILLUM DS
- NEW FOUNDATION - 44IN 1120MM
SB GC
23747 1 SIGN - MONUMENT ILLUM DS - 60IN 1425MM SB GC
SIGNAGE - OTHER
21297 1 SIGN - 5 MINUTE PARKING SB GC POST, IF REQUIRED, PROVIDED BY
OTHERS
Scale: 1/16" = 1'-0"1 SITE PLAN N
Revision Schedule
Rev Date By Description
ALL SITE WORK, HARDSCAPE, SIGNAGE FOOTINGS, AND BUILDING BY LL. SIGNAGE INSTALLED
BY GC OR VENDOR UNDER SEPERATE PERMIT.
Y 23113231137
2' -
2
1
/
2
"
1' - 4 3/4"
1' - 9 1/2"
S 2254422544
Y X1115X1115
6
S 2374723747 4
6
'
-
4
1
/
2
"
9' - 10
"
1
1
2
A003
7
A003
1
12
33' - 9 1/4"8' - 1 3/4"
Y 2254322543
Y 2254022540
8
9
12
Y 2254222542 1012
A004
2
A005
1
1
13
EQ
EQ
12' - 1"
2
Y X1115X1115 S 2254622546
Y 2311523115
Y 2311923119
S 2307423074 57
7
3
EQ EQ
11
13
20
'
-
9
"
6' - 11
1
/
4
"
5' - 0 3
/
4
"
1
1
1
1
5"
2
A501
9
Y X1115X1115 12
A003
10
1.LANDSCAPE AREA BY LL
2. 6” CONCRETE CURB BY LL
3.CANOPY (ABOVE) BY LL.
4.MONUMENT SIGN.
5.DT DIRECTIONAL EXIT/THANK YOU SIGN.
6.CLEARANCE BAR.
7.WAYFINDING PAVEMENT GRAPHICS BY LL.
8.DIGITAL ORDER SCREEN WITH CANOPY.
9.5-PANEL MENU BOARD BY SIGNAGE VENDOR.
10.DT PRE-MENU.
11.LL INSTALLED DETECTOR LOOP.
12.CONCRETE BOLLARD.
13.REINFORCED CONCRETE DRIVE-THRU LANE BY LL.
A.REFER TO EXTERIOR ELEVATIONS ON SHEET A201
FOR BUILDING SIGNAGE LOCATION AND DESIGN ID.
REFER TO ELECTRICAL PLANS FOR ELECTRICAL
REQUIREMENTS.
B. LANDSCAPING TO BE PROVIDED PER ZONING CODE
AND SUSTAINABILITY REQUIREMENTS.
C. DRIVE-THRU EQUIPMENT INCLUDING VEHICLE
DETECTION LOOP, WIRELESS COMMUNICATION AND
MONITORS SHALL BE COORDINATED BY STARBUCKS
CONSTRUCTION MANAGER. REFER TO ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.
D. PROVIDE 6" (150MM) THICK CONCRETE
PAVING THE LENGTH OF THE DRIVE-THRU LANE,
EXTENT TO INCLUDE DRIVE-THRU ENTRY POINT
THROUGH WINDOW STANDING PAD.
E. GENERAL CONTRACTOR TO APPLY CONCRETE
SEALER TO ALL EXTERIOR CONCRETE PATIO AND
WALKWAY SURFACES.
F.GENERAL CONTRACTOR TO VERIFY ALL EXISTING
ELEVATIONS AND BUILDING CONDITIONS IN FIELD
PRIOR TO START OF CONSTRUCTION.
G.PROVIDE DETECTABLE WARNING (IF APPLICABLE PER
LOCAL CODE) AT TRANSITION FROM SIDEWALK TO
DRIVE AISLE.
H.ACCESSIBLE PARKING SPACES AND ACCESS AISLES
SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN
ALL DIRECTIONS.
I.REFER TO ELECTRICAL DRAWINGS FOR SITE
RELATED ELECTRICAL WORK.
J.SCRAPE AND REPAINT ALL EXISTING PAINTED SITE
FEATURES, INCLUDING, BUT NOT LIMITED TO CURBS,
BOLLARDS, RAILINGS AND SITE LIGHTING BASES.
K.SEE SHEET A003-A006 FOR ARCHITECTURAL SITE
DETAILS.
L.ALL SITE FOOTINGS ARE TO BE PROVIDED BY LL. LL
TO INSTALL FOOTINGS ONLY PER APPROVED SIGN
STRUCTURAL ENGINEERING PLANS.
KEYED NOTES GENERAL NOTES
LANDSCAPE AREA BY LL
LEGEND
NEW 6" (150MM) CONCRETE CURB BY LL
NEW CONCRETE WALKWAY BY LL
CONCRETE DRIVE THRU LANE BY LL
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A002
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
ENLARGED SITE PLANS
Scale: 1/4" = 1'-0"3 ENLARGED PLAN - DT ENTRY
Scale: 1/4" = 1'-0"1 ENLARGED PLAN - DT ORDER POINT
Scale: 1/4" = 1'-0"2 ENLARGED PLAN - DT EXIT
N
ALL SITE WORK, HARDSCAPE, SIGNAGE FOOTINGS, AND BUILDING BY LL. SIGNAGE INSTALLED
BY GC OR VENDOR UNDER SEPERATE PERMIT.
Revision Schedule
Rev Date By Description
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD
AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND
INSTALL MENU BOARDS ONLY.
MIN.
1' - 9"
6" AVG.
ROAD
BED
CURB AND GRADE MAY
VARY PER LOCATION
4 x 4 x .25w
SQUARE STEEL
TUBE
NATURAL
FINISH OR
ENGINEERED
FILL
BASE PLATE
NON-
STRUCTURAL
BASE COVER
1
1
/
2
"
POST-INSTALLED ANCHORS NOT PERMITTED
DUE TO CLOSE SPACING OF ANCHOR BOLTS
8'
-
6
"
(
M
U
S
T
B
E
M
A
I
N
T
A
I
N
E
D
)
4"
7' - 11 3/4"
.
8' - 2 1/2"
(BTM. OF BASE
PLATE TO TOP
OF STEEL
TUBE)
SITE-SPECIFIC
FOOTING
ENGINEERING
REQUIRED BY
LICENSED
ENGINEER
ALL
ANCHORS
TO BE
PROVIDED
BY G.C.
(4) ANCHOR
BOLTS
BASE
OUTLINE 8"
8"
8"
8"8"8"
2' - 0"
2'
-
0
"
ELEVATION VIEW
3
1
/
2
"
1"
ANCHOR BOLT
(TYP. 1 OF 4)
HIGH STRENGTH
NON-SHRINKING
GROUT
PLAN VIEW
2"8"2"
1'
-
0
"
1' - 0"
12" X 12" X 3/4"
STEEL BASE PLATE
4" X 4" X 0.25"
SQUARE STEEL
TUBE POST
WELDED TO
BASE
THRU
HOLE FOR
MOUNTING
(TYP.)
2"
8"
2"
4"
4"
4"4"
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
TACK
NUT
TO
ROD 1/2" HEAVY HEX
NUT WITH WASHER
(4) 1/2" DIA. A36 THREADED HOT DIPPED GALVANIZED
THREADED ANCHOR RODS WITH GALVANIZED HARDWARE
(3) 1/2" HEAVY HEX NUTS &
WASHER - GALVANIZED
SEE GROUND FTG. DETAIL FOR ROD LENGTH
CENTER ANCHOR ROD
PATTERN IN FOUNDATION
3/
4
"
3/
4
"
7"
1"6"1"
8"
4"4"
3
1
/
2
"
3
1
/
2
"
6"
3 5/8" DIAMETER HOLE
11/16" DIAMETER BOLT
HOLE (TYP. 1 OF 4)
1/2" STEEL PLATE
CONDUIT STUB-UP
5
1
/
2
"
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
(4) ANCHOR
BOLTS
ALL
ANCHORS
TO BE
PROVIDED
BY LL
CONDUIT
STUB-UP
3" ABOVE
FOOTING
STEEL
BASE
PLATE
OUTLINE
ROUTE
CONDUIT
PER
ELECTRICAL
SITE PLAN
2' - 0" DIA.
9"3"3"9"
9
1
/
4
"
9
1
/
4
"
1'
-
0
"
1'
-
0
"
2
3
/
4
"
2
3
/
4
"
6"
FRONT ELEVATION SIDE ELEVATION
NATURAL
GRADE OR
ENGINEERED
FILL
CONDUIT
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU
ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY.
3' - 0"
2"
A
N
C
H
O
R
B
O
L
T
P
R
O
J
E
C
T
I
O
N
1
1
/
2
"
8"
2"
6'
-
0
"
4 1/2"6"4 1/2"
1' - 3"
2"
2"
2
1
/
4
"
7/
8
"
7/
8
"
4"
7 1/2"7 1/2"
3/8" STEEL PLATE
5/8" DIA. BOLT HOLE
(TYP. 1 OF 4)
1 1/4" DIA. HOLE FOR
CONDUIT STUB-UP
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
(4) ANCHOR
BOLTS
ALL
ANCHORS
TO BE
PROVIDED
BY G.C.
CONDUIT
STUB-UP
OFFSET
3" ABOVE
FOOTING STEEL
BASE
PLATE
OUTLINE
ROUTE
CONDUIT
PER
ELECTRICAL
SITE PLAN
2' - 0" DIA.
9"3"3"9"
10
7
/
8
"
10
7
/
8
"
1'
-
0
"
1'
-
0
"
1
1
/
8
"
1
1
/
8
"
FRONT ELEVATION
NATURAL
GRADE OR
ENGINEERED
FILL
CONDUIT
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU
ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY.
3'
-
8
"
M
A
X
.
1' - 8"
2"
3'
-
8
"
3'
-
8
"
SIDE ELEVATION
2"
A
N
C
H
O
R
B
O
L
T
P
R
O
J
E
C
T
I
O
N
1
1
/
2
"
4"
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A003
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
SITE DETAILS
Scale: 1/2" = 1'-0"1 DTE CLEARANCE BAR GROUND FOOTING
Scale: 3/4" = 1'-0"2 DTE CLEARANCE BAR BOLT PATTERN (TOP VIEW)
Scale: 1 1/2" = 1'-0"3 DTE CLEARANCE BAR BASE PLATE
Scale: 3" = 1'-0"4 DTE CLEARANCE BAR ANCHOR ROD
ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONSAND ENGINEERED DETAILS.
Scale: 3" = 1'-0"5 DTE MONUMENT BASE PLATE
Scale: 1 1/2" = 1'-0"6 DTE MONUMENT SIGNAGE BOLT PATTERN (TOP VIEW)
Scale: 3/4" = 1'-0"7 DTE MONUMENT SIGNAGE ELEVATION
Scale: 3" = 1'-0"8 DTE DIRECTIONAL SIGNAGE BASE PLATE
Scale: 1 1/2" = 1'-0"9 DTE DIRECTIONAL SIGNAGE BOLT PATTERN (TOP VIEW)
Scale: 3/4" = 1'-0"10 DTE DIRECTIONAL SIGNAGE GROUND FOOTING
Revision Schedule
Rev Date By Description
4 1/2"4"4"4 1/2"
1' - 5"
2"
4"
4"
2"
1'
-
0
"
FRONT EDGE
FACING DRIVE
THRU LANE
3/4" STEEL
BASE PLATE
THRU HOLE
FOR MOUNTING
(TYP.)
2 1/2" SQUARE
X 1/4" PLATE
WASHER
(TYP. 1 OF 4)
6 1/2"4"6 1/2"
ANCHOR BOLT
(TYP 1 OF 4)
6" X 3" X 0.1875"
STEEL POST
WELDED TO
BASE PLATE
MI
N
I
M
U
M
C
L
E
A
R
A
N
C
E
4'
-
6
"
(
1
3
7
2
M
M
)
30°
MENU BOARD
CONCRETE
FOOTING
BY LL
EDGE OF
CONCRETE
CURB
(1) CONDUIT,
ROUTE TO
ELECTRICAL
PANEL
40'-0" (12M) TO CENTERLINE OF
ORDER POINT MENU BOARD
(1372 MM)
4' - 6"
(3
0
5
M
M
)
1'
-
0
"
CONCRETE BOLLARD
ON CONCRETE
FOOTING PROVIDED
BY LL
(9
1
4
M
M
)
3'
-
0
"
SITE-SPECIFIC
FOOTING
ENGINEERING
REQUIRED BY
LICENSED
ENGINEER
2' - 0" DIA.
8"8"8"
4"4"
8"
8"
8"
ALL
ANCHORS
TO BE
PROVIDED
BY G.C.
CONDUIT
STUB-UP 3"
ABOVE
FOOTING
ANCHOR
BOLT
(TYP. 1 OF 4)
BASE
OUTLINE
DRIVE LANE
FACE THIS SIDE
ROUTE
CONDUIT PER
ELECTRICAL
SITE PLAN
4"
4"
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
TACK
NUT
TO
ROD 1/2" HEAVY HEX
NUT WITH WASHER
(4) 1/2" DIA. X 9" LENGTH A36 THREADED HOT DIPPED
GALVANIZED ANCHOR RODS WITH GALVANIZED
HARDWARE
(3) 1/2" - 13 HEAVY HEX NUTS
& WASHER - GALVANIZED
SEE GROUND FOOTING
DETAIL FOR ROD LENGTH CENTER ANCHOR ROD PATTERN IN FOUNDATION
ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:
HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 4"
EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED
THREADED STEEL RODS AND HARDWARE. (4) REQUIRED
8 3/4"
SIDE ELEVATION
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD
AND DRIVE THRU ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND
INSTALL MENU BOARDS ONLY.
FRONT ELEVATION
2' - 5 1/8"
NON-STRUCTURAL
BASE COVER
HOT DIPPED
GALVANIZED
LEVELING NUTS
(4) REQUIRED
STEEL MOUNTING
BASE WELDED TO
POST
NATURAL GRADE OR
ENGINEERED FILL
6" MIN..
1
1
/
2
"
1'
-
7
1
/
2
"
3'
-
5
3
/
8
"
8"
8"
8"
4"
4"2'
-
0
"
7"8"1' - 1"8"1' - 9"8"7"
6' - 0"
2' - 5"2"2"2"3' - 1"
ALL
ANCHORS TO
BE PROVIDED
BY G.C.
ANCHOR BOLT (TYP.):
(4) AT EACH CANOPY BASE PLATE
(4) AT DOS BASE PLATE
BASE COVER OUTLINE
OUTLINE OF CANOPY
BASE PLATE
(TYP. 1 OF 2))
ALL CONDUIT
STUB-UPS TO
BE 3" ABOVE
FOOTINGEDGE OF CONCRETE
FOOTING
ROUTE
CONDUIT PER
ELECTRICAL
SITE PLAN
OUTLINE OF DOS POST BASE PLATE
DOS STUB-UPS
DR
I
V
E
T
H
R
U
P
O
S
S
T
U
B
-
U
P
DR
I
V
E
T
H
R
U
P
O
S
S
T
U
B
-
U
P
EL
E
C
T
R
I
C
A
L
S
T
U
B
-
U
P
DE
T
E
C
T
O
R
L
O
O
P
S
T
U
B
-
U
P
1'
-
0
"
1'
-
0
"
DR
I
V
E
T
H
R
U
C
U
R
B
2'
-
3
"
T
O
F
A
C
E
O
F
4"4"CANOPY LIGHTING
1" DIA. STUB-UP;
ROUTE TO
SIGNAGE POWER
4"
1"
D
I
A
1"
D
I
A
1"
D
I
A
3/
4
"
D
I
A
ELECTRICAL TO BE INDIVIDUAL BRANCH CIRCUIT IN
DEDICATED CONDUIT TO BOH ELECTRICAL PANEL BY G.C.
FRONT ELEVATION
1
1
/
2
"
10
'
-
3
7
/
8
"
4' - 6"
5/8" HOT DIPPED
GALVANIZED
LEVELING NUTS
(12) REQUIRED
STEEL BASE PLATE
WELDED TO STEEL
POSTS BY MFR.
NATURAL GRADE
OR ENGINEERED
FILL
NON-STRUCTURAL
BASE COVER
DOS AND SPEAKER
CANOPY ABOVE
2"
C
L
R
.
1' - 5"6' - 7 7/8"
9'
-
1
0
"
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
SIDE ELEVATION
10
'
-
3
7
/
8
"
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU
ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY.
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
TACK
NUT
TO
ROD 5/8" HEAVY HEX
NUT WITH WASHER
(4) 5/8" DIA. A36 THREADED HOT DIPPED GALVANIZED
ANCHOR RODS WITH GALVANIZED HARDWARE
(3) 1/2" HEAVY HEX NUTS
& WASHER - GALVANIZED
SEE GROUND FOOTING
DETAIL FOR ROD LENGTH SEE SEPARATE DETAIL FOR ANCHOR ROD PATTERN IN FOUNDATION
ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:
HILTI 5/8" DIA. HVU ADHESIVE CAPSULES AT 9" EMBEDMENT WITH A36
HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE.
(12) REQUIRED
2"8"2"
4"
8"
2"
1' - 0"
1'
-
2
"
4" X 4" X 0.25" STEEL
TUBE POST WELDED
TO STEEL BASE PLATE
FRONT EDGE FACING
DRIVE THRU LANE
THRU HOLE FOR
MOUNTING (TYP.)
ANCHOR BOLT
(TYP 1 OF 4)
CUT-OUT
1 3/8" BASE
PLATE
2
5
/
8
"
1
3
/
8
"
4"4"
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A004
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
SITE DETAILS
ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONSAND ENGINEERED DETAILS.
Scale: 1 1/2" = 1'-0"1 DTE PRE-MENU BASE PLATE
Scale: 1/2" = 1'-0"2 PRE-MENU 30 DEG
Scale: 1 1/2" = 1'-0"3 DTE PRE-MENU BOLT PATTERN (TOP VIEW)
Scale: 3" = 1'-0"4 DTE PRE-MENU ANCHOR ROD
Scale: 3/8" = 1'-0"5 DTE PRE-MENU ELEVATION
Scale: 1" = 1'-0"6 DTE ORDER POINT CANOPY BOLT PATTERN (TOP VIEW)
Scale: 3/8" = 1'-0"8 DTE DOS CANOPY ELEVATION
Scale: 3" = 1'-0"7 DTE DOS CANOPY ANCHOR ROD
Scale: 1" = 1'-0"9 DTE DOS CANOPY BASE PLATE
Revision Schedule
Rev Date By Description
(3
0
5
M
M
)
1'
-
0
"
(730MM)
2' - 5"4' - 2" (1270MM)6' - 1" (1854MM)
3'
-
3
"
(
9
9
1
M
M
)
15°(1) CONDUIT,
ROUTE TO
ELECTRICAL
PANEL
CONCRETE
FOOTING BY LL
MENU
BOARD
MI
N
.
C
L
R
.
A
R
E
A
4'
-
1
"
(
1
2
4
5
M
M
)
15' - 2" (4623MM) MIN. CLR. AREA
MI
N
.
C
L
R
.
1'
-
0
"
(
3
0
5
M
M
)
DIGITAL ORDER SCREEN (DOS) AND SPEAKER
LL PROVIDED DETECTOR LOOP EDGE CENTERED ON DOS POST 2"
(51MM) BELOW FINAL GRADE IN CONDUIT OR SAWCUT. VERIFY NO
METAL IN SLAB WITHIN 36" (915MM) OF LOOP.
CONDUIT TO DOS POST
EDGE OF LL PROVIDED CONCRETE FOOTING (DATUM
POINTS REPRESENT CENTER OF (2) CANOPY BASE PLATES)
EDGE OF EXISTING CONCRETE CURB
(1) CONDUIT, STUB UP FOR CANOPY LIGHTING,
ROUTE TO SIGNAGE POWEROUTLINE OF CANOPY ABOVE
CANOPY POST (TYP. 1 OF 2)
(2) CONDUIT FROM DOS
POST, ROUTE TO DRIVE THRU
WINDOW
(1) CONDUIT FROM DOS
POST, ROUTE TO ELECTRICAL
PANEL
CONCRETE BOLLARD ON
CONCRETE FOOTING
36" x 36" (915MM) MIN. CLEAR
AREA ACCESS
DOS POST
(6
8
6
M
M
)
2'
-
3
"
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU
ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY.
FRONT ELEVATION
NON-STRUCTURAL
BASE COVER
HOT DIPPED
GALVANIZED LEVELING
NUTS (4) REQUIRED
STEEL MOUNTING
BASE PLATE
WELDED TO
STEEL POST
SIDE ELEVATION
NATURAL GRADE OR
ENGINEERED FILL
1
1
/
2
"
8" MIN..
CONDUIT
3'
-
6
3
/
4
"
1'
-
6
3
/
4
"
7' - 10 1/2"1' - 1 1/2"
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
SEE SEPARATE DETAIL FOR ANCHOR ROD PATTERN IN FOUNDATION
ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:
HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 8" EMBEDMENT WITH A36
HOT-DIPPED GALVANIZED THREADED STEEL RODS AND HARDWARE.
(4) REQUIRED
TACK
NUT
TO
ROD 1/2"
HEAVY HEX NUT
WITH WASHER
(4) 1/2" DIA. A36 THREADED HOT DIPPED GALVANIZED
ANCHOR RODS WITH GALVANIZED HARDWARE
(3) 1/2" HEAVY HEX NUTS
& WASHER - GALVANIZED
SEE GROUND FOOTING
DETAIL FOR ROD LENGTH
8" X 4"
X 0.1875"
STEEL
TUBE
POST
WELDED
TO BASE
PLATE
3"
8"
3"
1' - 6"
7"4"7"
7"
7"
1'
-
2
"
THRU HOLE
FOR MOUNTING
(TYP.)
2 1/2" SQUARE
X 1/4" PLATE
WASHER
(TYP. 1 OF 4))
3/4" STEEL
BASE PLATE
FRONT EDGE
FACING DRIVE
THRU LANE
2"5"5"2"2"2"
5"2"4"2"5"
ANCHOR BOLT
(TYP 1 OF 4)
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
ALL
ANCHORS
TO BE
PROVIDED
BY G.C.
CONDUIT
STUB-UP
3" ABOVE
FOOTING
(4) ANCHOR
BOLTS
BASE
PLATE
OUTLINE
FRONT EDGE
OF DRIVE LANE
SIDE
ROUTE CONDUIT
PER ELECTRICAL
SITE PLAN
11"8"11"
4"
4"
11
"
8"
11
"
1' - 3"1' - 3"
2' - 6" DIA.
ALL ANCHORS
TO BE
PROVIDED BY
G.C.
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
ROUTE
CONDUIT PER
ELECTRICAL
SITE PLAN
(4) ANCHOR
BOLTS
BASE
OUTLINE
DRIVE THRU
LANE FACE
THIS SIDE
CONDUIT STUB-UPS
3" ABOVE FOOTING
DE
T
E
C
T
O
R
L
O
O
P
S
T
U
B
-
U
P
DR
I
V
E
T
H
R
U
P
O
S
S
T
U
B
-
U
P
DR
I
V
E
T
H
R
U
P
O
S
S
T
U
B
-
U
P
EL
E
C
T
R
I
C
A
L
S
T
U
B
-
U
P
2' - 0" DIA.
8"4"4"8"
8"
4"
4"
8"
2"1"1"2"
1"
D
I
A
1"
D
I
A
1"
D
I
A
3/
4
"
D
I
A
ELECTRICAL TO BE
INDIVIDUAL BRANCH CIRCUIT
IN DEDICATED CONDUIT TO
BOH ELECTRICAL PANEL
ALL CONDUIT STUB-UPS TO
BE 3" ABOVE FOOTING
SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
LL IS RESPONSIBLE FOR FOUNDATIONS AND FOOTINGS ON ALL MENU BOARD AND DRIVE THRU
ELEMENTS. SIGNAGE VENDOR TO SUPPLY TEMPLATES AND INSTALL MENU BOARDS ONLY.
NON-STRUCTURAL
BASE COVER
FRONT ELEVATION SIDE ELEVATION
HOT DIPPED
GALVANIZED
LEVELING NUTS
(4) REQUIRED
STEEL MOUNTING BASE
WELDED TO POST
NATURAL GRADE OR
ENGINEERED FILL
1
1
/
2
"
4'
-
1
3
/
4
"
1'
-
9
3
/
4
"
2' - 5 1/4"8 1/4"9 3/8"
0.625" STEEL
BASE PLATE
1' - 2 1/4"
3 1/8"EQ EQ 3 1/8"
2
1
/
4
"
2
1
/
4
"
EQ
EQ1'
-
0
1
/
2
"
THRU HOLES FOR
MOUNTING (TYP.)
9.843" X 3.973 X 3/16"
STEEL POST
WELDED TO STEEL
BASE PLATE
FRONT EDGE
FACING DT LANE
2 1/2" SQUARE
X 1/4" PLATE
WASHERS
(TYP. 1 OF 4)
ANCHOR BOLT
(TYP 1 OF 4)SITE-SPECIFIC FOOTING ENGINEERING REQUIRED BY LICENSED ENGINEER
TACK
NUT
TO
ROD 1/2" HEAVY HEX
NUT WITH WASHER
(4) 1/2" DIA. X 9" LENGTH A36 THREADED HOT DIPPED
GALVANIZED ANCHOR RODS WITH GALVANIZED
HARDWARE
(3) 1/2" - 13 HEAVY HEX NUTS
& WASHER - GALVANIZED
SEE GROUNG FOOTING
DETAIL FOR ROD LENGTH CENTER ANCHOR ROD PATTERN IN FOUNDATION
ALTERNATE ADHESIVE POST-INSTALLED ANCHORS:
HILTI 1/2" DIA. HVU ADHESIVE CAPSULES AT 4"
EMBEDMENT WITH A36 HOT-DIPPED GALVANIZED
THREADED STEEL RODS AND HARDWARE. (4) REQUIRED
EM
B
E
D
M
E
N
T
2'
-
6
"
M
I
N
2'
-
6
"
6" (150mm)
STEEL PIPE FILLED
WITH CONCRETE
PAVING OR
CONCRETE
SLAB
EXPANSION
JOINT (SEALANT)
CONCRETE
FOOTING BY GC
CONCRETE
DOME
CONCRETE FILLED
DIAMETER
1' - 0"
3'
-
0
"
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A005
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
SITE DETAILS
ALL SITE SIGNAGE DETAILS ARE FOR REFERENCE ONLY; STARBUCKS SIGNAGE VENDOR TO PROVIDE FINAL PERMITTED DRAWINGS, SPECIFICATIONSAND ENGINEERED DETAILS.
Scale: 1/2" = 1'-0"1 DTE - 5 PANEL 15º DT MENU BOARD, DIGITAL ORDER SCREEN WITH CANOPY
Scale: 3/8" = 1'-0"2 DT 5-PANEL MENU BOARD GROUND FOOTING
Scale: 3" = 1'-0"4 DTE 5-PANEL MENU BOARD ANCHOR ROD
Scale: 1 1/2" = 1'-0"5 DTE 5-PANEL MENU BOARD BASE PLATE
Scale: 1 1/2" = 1'-0"6 DTE 5-PANEL MENU BOARD BOLT PATTERN (TOP VIEW)
Scale: 1 1/2" = 1'-0"7 DTE DOS POST BOLT PATTERN (TOP VIEW)
Scale: 3/8" = 1'-0"8 DTE DOS POST ELEVATION
Scale: 1 1/2" = 1'-0"9 DTE DOS POST BASE PLATE
Scale: 3" = 1'-0"10 DTE DOS POST ANCHOR ROD
Revision Schedule
Rev Date By Description
Scale: 3/4" = 1'-0"3 CONCRETE BOLLARD
1.OUTLINE OF BAR PER CASEWORK MANUFACTURER.
2.ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM
CLEARANCE AS REQUIRED BY CODE.
3.ALIGN FACE OF FINISHED WALL.
4.SHELF FOR WATER HEATER ABOVE. REFER TO
INTERIOR ELEVATION FOR HEIGHT AND DETAILS FOR
CONSTRUCTION OF PLATFORM AND SUPPORTING
ASSEMBLY. SEE 6/A501 FOR DETAIL.
5.FUR OUT INTERIOR FACE OF WALL.
KEYED NOTES GENERAL NOTES
A.GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS
AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF
ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL
DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM
POINT.
B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED
WOOD STUD BLOCKING, OR EQUIVALENT TO SUPPORT
ANY WALL ATTACHMENT AND/OR SIGNAGE.
C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD
EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE
CODE, REMOVE AND REPLACE WITH ACCESSIBLE
THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL
CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED
WITH A SLOPE NO GREATER THAN 1:12.
D.ALL DIMENSIONS ARE TO FINISHED FACE UNLESS
SHOWN OR NOTED OTHERWISE.
E.. INSTALL MOISTURE RESISTANT GREEN BOARD ON
BACKBAR WALL PER PROJECT MANUAL.
F. ALL DOORS SHALL BE 32 ” (815MM) MINIMUM CLEAR
OPENING WHEN OPENED TO 90 DEGREE POSITION
UNLESS OTHERWISE NOTED.
G.SEE SHEET A601 FOR EXTERIOR DOOR AND WINDOW
SCHEDULES.
H.STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE
COMPONENTS AND GC TO INSTALL.
I. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES
MEET STARBUCKS AND/OR CODE REQUIREMENTS.
J.PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE
APPROVED PLANS FROM THE CITY.
K.SEE STRUCTURAL FOR KNEE WALL BRACING.
L.SEE SHEET A501 FOR BUILDING DETAILS.
M.REFER TO SHEET I104 FOR FLOOR FINISHES.
NEW PARTIAL HEIGHT WALL
NEW FULL HEIGHT WALL
EXISTING WALL
GENERAL LEGEND
WALL BLOCKING CALL-OUTXX
XX WALL SHEATHING CALL-OUT
WALL SHEATHING KEY
SYMBOL DESCRIPTION
5/8" GYP. WALL BOARD
(FULL WALL HEIGHT)A
5/8" GYP. WALL BOARD
(TERMINATE AT 6" (150MM)
ABOVE CEILING)B
C
5/8" CEMENTITIOUS BACKER
BOARD (TERMINATE AT 6"
(150MM) ABOVE CEILING)
D
5/8" GREENBOARD (TERMINATE
AT FINISH TRANSITION AS
SHOWN ON INTERIOR
ELEVATION W/ 5/8" GYP. WALL
BOARD ABOVE (FULL WALL
HEIGHT)).
E
5/8" PURPLE BOARD
(TERMINATE AT 6" (150MM)
ABOVE CEILING)
5/8" PLYWOOD
(TERMINATE AT 6" (150MM)
ABOVE CEILING)
INDICATES SHEATHING
TRANSITION
F
D
D
D
D
C
C
D
D
D
D
D
D
B EE
E
EB
D
F
D
D
D
D
DD
D
D
D
D
D
D
F
D
D
D
D
D
G G
GG
H
2' - 4"4' - 0"6 3/4"10 3/4"20' - 9 3/4"10 3/4"
3'
-
6
"
6'
-
1
1
/
2
"
7'
-
9
1
/
4
"
8' - 5"3' - 6 1/4"2' - 10"
8' - 0 1/2"4' - 8 3/4"9' - 11 3/4"2' - 8 1/2"
9' - 3"
3'
-
5
1
/
4
"
6'
-
6
3
/
4
"
3'
-
1
0
1
/
4
"
2'
-
0
1
/
2
"
1' - 3 1/4"14' - 7 1/2"
5' - 1"
7
1
/
4
"
2'
-
1
3
/
4
"
Q
L
F
F
F
F
B A
M
K
C
E
D
P
P
S
3-F-A
6-T-N
4-F-A
3-F-A
4-F-A4-F-A
3-F-A
3-F-A
4-F-N
2-F-N 4-F-N
3-T-A
6-T-N
3-T-N
6-T-N
6-T-N
D 10190 01
D 10190 02
D EXTG E2
D EXTG E1
5
3 3
24 5
5
5
5
4
1
1
1
CAFE
WORKROOM
RESTROOM
VEST.RESTROOM 1
RESTROOM 2
ENGINE
2-F-N
6'
-
5
1
/
4
"
2-F-N
3-P-N
3 33
3
F F D D
F
E
E
EEE
2' - 7 1/4"
3' - 0"
2'
-
0
1
/
2
"
2'
-
6
1
/
2
"
10 3/4"
2'
-
6
3
/
4
"
8'
-
0
"
8'
-
3
"
B
7'
-
6
3
/
4
"
4
3
/
4
"
7 1/4"
5
DRIVE-THRU
A501
4
A501
6
2-T-N
2-T-N2-T-N
E
1-F-N 1-F-N 1-F-N 555
3
WALL BLOCKING KEY
SYMBOL ITEM
128 LBS
(58 KG)
WEIGHT
36" TO 40"
(915MM TO 1015MM)
HEIGHT A.F.F.
30" (760MM) BEHIND SINKA
APPROX. WIDTH
SHELVES ABOVE
COMPARTMENT SINK
200 LBS
(91 KG)
48" TO 76"
(1220MM TO 1930MM)
96" (2440MM) CENTERED ABOVE
COMPARTMENT SINKB
C BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR
SHELVES AT
MANAGER'S DESK
300 LBS
(136 KG)
32" TO 96"
(810MM TO 2440MM)
48" (1220MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON
SHELVES
D
EQUIPMENT RACK AT
MANAGER'S DESK
300 LBS
(136 KG)
44" TO 96"
(1120MM TO 2440MM)
28" (710MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON RACKE
F
BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR. IN-
WALL BLOCKING PREFERRED, HOWEVER EXISTING FRP FINISHED
WALL MAY RECEIVE SURFACE MOUNTED, PAINTED WHITE.
30" TO 36"
(760MM TO 915MM)
60" (1525MM) AROUND WATER
CLOSETG200 LBS
(91 KG)
COMMERCIAL INSTALLATION REQUIRES CONCEALED
ARM CARRIER. REFER TO MFR'S SPECIFICATION.H 200 LBS
(91 KG)
BLOCKING SPECIFICATION FOR FRENCH CLEATING SYSTEM.
REFER TO DETAILS.I
BLOCKING SPECIFICATION FOR CBE METAL SHELVES.
REFER TO VENDOR'S SPECIFICATION AND DETAILS.K
COORDINATE LOCATION AND EXTENT WITH PENTAIRLTBD BY
VENDOR
ALL ARTWORK,
FIXTURES,
ACCESSORIES AND
CASEWORK
FABRICATIONS NOT
OTHERWISE NOTED
GC TO PROVIDE WALL BLOCKING AS REQUIRED FOR
ALL ITEMS FOR A COMPLETE AND SECURE
INSTALLATION. EXTEND BLOCKING 8" (205MM)
BEYOND ON EACH SIDE OF EACH ITEM.
TBD BY
VENDOR
(VARIES)
WORKROOM
HAND SINK
UPPER
WIRE SHELVES
RESTROOM
GRAB BARS
RESTROOM
HAND SINK
METRO
SHELVES
MILLWORK
BOXES
UPPER CBE
SHELVING
WATER FILTRATION
SYSTEM
60" TO 72"
(1525MM TO 1830MM)M 300 LBS
(136 KG)
LOCKERS
(3/4" PLYWOOD)
18" (455MM) PAST LOCKERS
EA. SIDE
4'-0" TO 6'-6" N 100 LBSDRIVE THRU
COMMUNICATIONS
EQUIPMENT
4'-0" BEHIND POS AND BARISTA
AT DRIVE THRU WINDOW
3'-4" TO 5'-2" P 250 LBSVERTICAL GRAB BAR BETWEEN STUDS BEHIND
GRAB BAR
Q
S ORDER STATUS
BOARD (OSB)BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A101
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
BUILDING FLOOR PLAN
Scale: 1/4" = 1'-0"1 FLOOR PLAN
N
Revision Schedule
Rev Date By Description
INTERIOR WALL SCHEDULE
TAG DESCRIPTION INSULATION NOTES
1-F-N 1 1/2" 20 GA STUD FURRING WALL NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING.
2-F-N 3 5/8" 20 GA STUD FURRING WALL NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING.
2-T-N 3 5/8" 20 GA STUD FURRING WALL NONE TERMINATE 6" ABOVE CEILING. SEE PLAN FOR WALL SHEATHING.
3-F-A 3 5/8" 20 GA STUDS @ 16" O.C.ACOUSTIC FULL HT. WALL. SEE PLAN FOR WALL SHEATHING.
3-P-N 3 5/8" 16 GA STUDS @ 16" O.C.NONE PARTIAL HT. WALL W/ RCKW RIGID CONNECTORS AT FLOOR. SEE
ELEVATIONS FOR WALL HT. SEE PLAN FOR WALL SHEATHING.
3-T-A 3 5/8" 20 GA STUDS @ 16" O.C.ACOUSTIC TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD
BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE.
SEE PLAN FOR WALL SHEATHING.
3-T-N 3 5/8" 16 GA STUDS @ 16" O.C.NONE TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD
BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE.
SHEATHING ONE SIDE. SEE PLAN FOR WALL SHEATHING.
4-F-A 6" 20 GA STUDS @ 16" O.C.ACOUSTIC FULL HT. WALL. SEE PLAN FOR WALL SHEATHING.
4-F-N 6" 20 GA STUDS @ 16" O.C.NONE FULL HT. WALL. SEE PLAN FOR WALL SHEATHING.
6-T-N 6" 20 GA STUD FURRING WALL NONE TERMINATE 6" ABOVE CEILING. PROVIDE 45 DEGREE METAL STUD
BRACING AT 48" O.C. FROM STUD WALL TO STRUCTURE ABOVE.
SHEATHING ONE SIDE. SEE PLAN FOR WALL SHEATHING.
1. ELECTRICAL STUB-UP LOCATION. SEE ELECTRICAL
SHEETS.
2.PLUMBING STUB-UP LOCATION. SEE PLUMBING
SHEETS
3.FLOOR SINK LOCATION. SEE PLUMBING SHEETS.
4.FLOOR DRAIN LOCATION. SEE PLUMBING SHEETS.
5.APPROXIMATE LOCATION OF LL PROVIDED GI.
6.MOP SINK WASTE.
7.WATER CLOSET WASTE.
8.BANQUETTES WITH POWER.
A. ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED
WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN).
REFER TO FLOOR PLAN FOR WALL PLACEMENT.
B. FLOOR SINK: REFER TO CUT SHEETS FOR COMPONENT
SPECIFICATIONS AND CUTOUT REQUIREMENTS.
C. WASTE LINE PENETRATIONS: REFER TO PLUMBING
PLANS FOR INDIVIDUAL LINE LOCATIONS.
D. STUB-UP PENETRATIONS: REFER TO ELECTRICAL AND
PLUMBING PLANS FOR INDIVIDUAL STUB-UP LOCATIONS.
E. TOILET FLOOR PENETRATION: REFER TO CUT SHEETS
FOR STUB-UP LOCATION RELATIVE TO FINISHED WALL.
F. PENETRATION TO BE LOCATED ON CENTERLINE OF
WALL OR AS REQUIRED PER CONDITIONS.
G. TRENCHING OUTLINE FOR GUIDELINE USE ONLY.
GENERAL CONTRACTOR TO COORDINATE WITH
SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE
ACTUAL LAYOUT.
H.REFER TO SHEET I105 FOR FLOOR FINISHES.
KEYED NOTES GENERAL NOTES
EXISTING WALL
LEGEND
DATUM POINT
FLOOR DRAIN
FLOOR CLEAN-OUT
FLOOR SINK
ADJACENT
TENANT
(NO WORK)
16' - 0 1/4"
17' - 7 3/4"
21' - 5 3/4"
21' - 7 1/4"
27' - 8 1/4"
2'
-
9
3
/
4
"
1'
-
1
0
3
/
4
"
4'
-
5
1
/
2
"
17
'
-
1
1
/
2
"
13' - 11"
1' - 6"
1'
-
2
1
/
4
"
1'
-
3
3
/
4
"
13' - 3 1/4"
14' - 3 1/2"
38' - 8 3/4"
2'
-
0
1
/
2
"
9'
-
5
"
P 10726
P 10294
P 10726
P 10294
P 10726
P 10726
P 10294
P 10726
P 10294
7
7 6
3
3
3 3
3
3
1
1
2
8
3'
-
9
1
/
4
"
11
'
-
9
1
/
2
"
P 10594
P 105944
4
3' - 8 1/4"
11' - 9 1/4"
P 10594
4
10' - 11 1/4"
2'
-
3
1
/
4
"
P 10294
P 107263
44' - 6"
2'
-
1
1
3
/
4
"
37' - 9"
8'
-
1
1
/
2
"
P 10726
P 10294 3
CAFE
RESTROOM
VEST.
RESTROOM 1
RESTROOM 2
WORKROOM
ENGINE
A501
2
A501
3 A501
1
DRIVE-THRU
5
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A102
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
BUILDING FLOOR
PENETRATION PLAN
Scale: 1/4" = 1'-0"1 FLOOR PENETRATION PLAN
N
Revision Schedule
Rev Date By Description
1.PROVIDE J-BOX FOR BUILDING SIGNAGE. COORDINATE
LOCATION WITH SIGNAGE VENDOR SHOP DRAWINGS.
2.PROVIDE SIGNAGE DISCONNECT ON INSIDE FACE OF
WALL.
3.3/4" MARINE GRADE PLYWOOD BLOCKING FOR EXTERIOR
SIGNAGE. EXTEND BLOCKING 8" (205MM) MIN. BEYOND
EDGE OF SIGNAGE.
4.DT WINDOW BY LL.
5.STEEL CANOPY BY LL.
6.EXISTING BUILDING SHELL AND FINISHES BY LL.
7.EXTERIOR SCONCE LIGHTING BY LL.
8.DOWNSPOUT BY LL.
A.GENERAL CONTRACTOR TO COORDINATE AND SCHEDULE
SIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTOR
PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS
AND 1 WEEK PRIOR TO SCHEDULED DATE OF
INSTALLATION. CONSTRUCTION MANAGER TO PROVIDE
GENERAL CONTRACTOR WITH SIGNAGE CONTRACTOR
CONTACT INFORMATION.
B.GENERAL CONTRACTOR SHALL COORDINATE WITH
ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL
ELECTRICAL CIRCUITS INCLUDING ALL CONDUIT, WIRE,
CONNECTIONS AND BREAKER AT PANEL BOARD
NECESSARY TO SERVE SIGNAGE.
C.GENERAL CONTRACTOR TO PROVIDE FIRE TREATED
WOOD STUD BLOCKING OR EQUIVALENT TO SUPPORT
SIGNAGE.
D.SIGNAGE CONTRACTOR SHALL VERIFY SIZE AND
LOCATION OF ANY AND ALL ALLOWABLE MONUMENT OR
POLE SIGNAGE AND PROVIDE SHOP DRAWING(S) PRIOR
TO FABRICATION TO THE STARBUCKS DESIGNER FOR
APPROVAL.
E. SIGNAGE CONTRACTOR TO INSTALL SIGNAGE IN
COMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT.
F.SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TO
CONSTRUCTION MANAGER AND TO THE GENERAL
CONTRACTOR AS NEEDED. GENERAL CONTRACTOR TO
NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF SHOP
DRAWINGS OR INSTALLATION IS IN DISCREPANCY WITH
ARCHITECTURAL DRAWINGS.
G.GENERAL CONTRACTOR TO CLEAN, PATCH AND
REPAIR EXISTING EXTERIOR AS REQUIRED.
KEYED NOTES GENERAL NOTES
EQEQ
EQ
EQ
S 2260622606123
5 5 5777 7
6
8
Z X19131
EQ EQ
EQ
EQ
S 2260622606 1 2 3
4
5
7
6
8G2387823878
16
'
-
4
1
/
4
"
1'
-
2
"
EXTENT OF ARTWORK, VIF
49' - 0"
PAINTABLE EXTERIOR MURAL8
EQ EQ
EQ
EQ
1 S 2260622606
7 7
6
23
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A201
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
BUILDING EXTERIOR
ELEVATIONS
Scale: 3/16" = 1'-0"1 EXTERIOR ELEVATION - NORTH
Scale: 3/16" = 1'-0"2 EXTERIOR ELEVATION - EAST
Scale: 3/16" = 1'-0"3 EXTERIOR ELEVATION -WEST
Revision Schedule
Rev Date By Description
EQ EQ
7"
EQ
EQ
3"
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 CWF STUB-UP 3/4" LINE
2 CW STUB-UP 3/4" LINE
ESPRESSO BAR PLUMBING STUB-UP KEY
1 2
POS DIEWALL
NOTE :SEE SHEET A102 - BUILDING
FLOOR PENETRATION PLAN FOR
FINAL DIMENSIONED LOCATION.
3
3
/
4
"
1
EQ
EQ
3"
EQ EQ
1' - 9"
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
2 3 3 3 3
3
1
/
2
"
ESPRESSO BAR DIEWALL
1 3/4" LAN CONDUIT
2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION
3 3/4" ISOLATED GROUND POWER CONDUIT
ESPRESSO BAR ELECTRICAL STUB-UP KEY
NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 3/4" POWER CONDUIT TO ELECTRICAL PANEL
2 1/2" PHONE TO MANAGER'S DESK
3 1/2" DATA CONDUIT TO MANAGER'S DESK
POS ELECTRICAL STUB-UP KEY
4 1/2" SECURITY TO MANAGER'S DESK
5 3/4" LAN CONDUIT TO POS/SAFE
6 3/4" POWER CONDUIT FOR PASTRY CASE
POS DIEWALL
EQ
EQ
3"
EQ EQ
1' - 6"
7"1 2 5 634
NOTE:SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
6
1
/
2
"
11
1
/
2
"
1'
-
9
1
/
2
"
VA
R
I
E
S
DR
I
V
E
T
H
R
U
B
U
M
P
D
E
P
T
H
V
A
R
I
E
S
1
FINISH FACE OF
INTERIOR CORNER AT
DRIVE THRU POS WALL
DRIVE
THRU
POS
1
VIDEO CONDUIT
FROM DRIVE
THRU ORDER
POINT(S)
AUDIO CONDUIT
FROM DRIVE
THRU ORDER
POINT(S) AND
DETECTOR
LOOP(S)
CONDUIT FROM
DT WINDOW2
3
IN-WALL DRIVE
THRU CONDUIT
STUB-UP KEY
EXTERIOR WALL
ASSEMBLY
2
3
.
.INTERIOR
FURRING
BOT OF SHELF
5'-10" AFF
5/8" WATER
RESISTANT
GYP. BD
3/4" PLYWOOD FLOOR
SCREWS @ 6" O.C.
(2) 362S162-43
STUDS @ 8" O.C. @
WATER HEATER
SHELF
SIMPSON 'L50'
CLIP 2 SIDES W/
(5) #10 SCREWS
TYP EA LEG
(2) 362S162-43 STUDS
@ 8" O.C. @ WATER HEATER SHELF
(2) 600S162-43 STUDS
@ 8" O.C.,
ALIGN W/ STUDS
5
A501
7
A501
SEE FLOOR PLAN
2'
-
2
"
.
BOT OF SHELF
PER ELEVATION
5/8" WATER
RESISTANT
GYP. BD
3/4" PLYWOOD FLOOR
SCREWS @ 6" O.C.
(2) 600S162-43 STUDS
@ 8" O.C. @ WATER
HEATER SHELF
2' - 2".
SEISMIC STRAPPING:
16 GA X 1" WIDE
METAL STRAP w/ MIN.
(4) #10 SCREWS EA
STRAP INTO STUDS
A501
8 NOTE:
SEISMIC STRAPPING
LOCATIONS @ TOP 3RD
& BOT 3RD OF WATER
HEATER.
BOT OF SHELF
PER ELEVATION
3/4" PLYWOOD FLOOR
WATER RESISTENT
GYP BD
(2) 600S16-43 BOX BEAM
STAINLESS STEEL
METAL CORNER GUARD
5/8" WATER
RESISTANT GYP. BD
AIR CURTAIN
AND HEATER
SIDE FILTERS
(INCLUDED)
DRIVE THRU
WINDOW PER
PLAN (BY
LANDLORD)
SHELF PER
PLAN
INTERIOR FINISH GRADE
EXTERIOR FINISH GRADE
PLAN
CU
R
B
6"
(
1
5
0
M
M
)
MAX.
1' - 6" (450MM)
BOLLARD
MI
N
.
C
L
E
A
R
5'
-
0
"
(
4
6
0
M
M
)
10' - 1" (3075MM) MAX CLEAR
9' - 1" (2770MM) MIN. CLEAR
14
"
(
3
5
5
M
M
)
M
A
X
.
12
"
(
3
0
5
M
M
)
M
I
N
.
CENTERLINE OF
DRIVE THRU
WINDOW
CONCRETE CURB
CONCRETE INFILL
AT BUMP OUT
DRIVE THRU WINDOW
AND SHELF PER PLAN
DETECTOR LOOP EDGE
CENTERED ON DRIVE
THRU WINDOW 2"
(50MM) BELOW FINAL
GRADE IN CONDUIT OR
SAWCUT. ROUTE (1)
CONDUIT TO DRIVE
THRU POS AND
TERMINATE NEAR TIMER
SIGNAL PROCESSOR
(TSP). VERIFY THAT NO
METAL IN SLAB WITHIN
36" (915MM) OF LOOP.
WINDOW CONFIGURATION
PER PLAN
BOLLARD
ELEVATION
DRIVE THRU
SHELF PER
PLAN
(9
1
5
M
M
)
3'
-
0
"
12
A501
1
3
/
4
"
(
4
5
m
m
)
(5
0
m
m
)
2"
ALIGN
STAINLESS STEEL
ANGLE TO CAP
INTERIOR WALL.
HEM BOTTOM EDGE
SHELF PER
ELEVATION
EXTERIOR WALL ASSEMBLY
PER SHELL BUILDING PERMIT
+/
-
2
"
(
5
0
m
m
)
3'
-
6
"
(
1
0
6
5
m
m
)
14" (355mm) MAXIMUM
12" (300mm) MINIMUM
-------------------------
HO
L
D
3'
-
0
"
(
9
1
5
m
m
)
A
.
F
.
F
.
SINGLE PANEL DRIVE-THRU
WINDOW ASSEMBLY PER PLAN
ATTACH SHELF TO BUILDING
EXTERIOR FLUSH TO TOP OF
ROUGH OPENING,
CENTERED ON WINDOW
EXISTING
EXTERIOR WALL
SYSTEM
A501
11
AIR CURTAIN BY LL
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A501
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
BUILDING DETAILS
Scale: 1 1/2" = 1'-0"1 PLUMBING STUB-UPS AT ESPRESSO BAR
Scale: 1 1/2" = 1'-0"2 ELECTRICAL STUB-UPS AT ESPRESSO BAR
Scale: 1 1/2" = 1'-0"3 ELECTRICAL STUB-UPS AT POS
Scale: 3/4" = 1'-0"4 DRIVE THRU POS IN-WALL CONDUIT STUB-UPS
Scale: 1/2" = 1'-0"5 CROSS SECTION @ WATER HEATER SHELF
Scale: 3/4" = 1'-0"6 PLAN @ WATER HEATER SHELF
Scale: 1/2" = 1'-0"7 SECTION @ WATER HEATER SHELF
Scale: 3" = 1'-0"8 SHELF EDGE DETAIL
Revision Schedule
Rev Date By Description
Scale: 1/2" = 1'-0"10 DRIVE THRU WINDOW AND AIR CURTAIN
Scale: 1/4" = 1'-0"9 DTE - DRIVE THRU WINDOW BUMP-OUT
Scale: 1 1/2" = 1'-0"11 DRIVE THRU WINDOW SHELF SECTION
Scale: 1/2" = 1'-0"12 DRIVE THRU WINDOW SECTION
A.STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE
COMPONENTS. GC TO INSTALL.
B.SEE SHEET A101 FOR TAGGED LOCATION OF EXTERIOR
DOORS AND WINDOWS.
C.EGRESS SHALL NOT PASS THROUGH KITCHENS,
STORAGE ROOMS, CLOSETS OR SIMILAR SPACES.
(1016.2 IBC)
D.PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON
DOORS IN THIS BUILDING SHALL SATISFY THE FOLLOWING
(1010.2.9 IBC):
a)THE ACTUATION PORTION OF THE RELEASING DEVICE
SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR
LEAF WIDTH.
b)THE MAXIMUM UNLATCHING FORCE DOES NOT
EXCEED 15 POUNDS (6.8 KG).
c)PIVOTED OR BALANCED DOORS SHALL BE OF THE
PUSH-PAD TYPE WHERE PANIC HARDWARE IS
REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS
MORE THAN ONE-HALF OF THE DOOR WIDTH,
MEASURED FROM THE LATCH SIDE.
d)PANIC HARDWARE LISTED IN ACCORDANCE WITH
UL 305.
e) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH
UL 10C AND UL 305.
E.SPY SCOPE HARDWARE, WHERE INSTALLED SHALL BE
CENTERED IN DOOR AT 54" (1370MM) A.F.F.
GENERAL NOTES
DOOR LEGEND
STOREFRONT
METAL FRAME
DOUBLE
(TYPE A)
STOREFRONT
METAL FRAME
SINGLE
(TYPE B)
SINGLE
FLUSH
(TYPE 1)
EXTERIOR EXTERIORINTERIOR
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
A601
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
WINDOW AND DOOR
SCHEDULES & DETAILS
DOOR SCHEDULE - "D"
DESIGN ID MARK DESCRIPTION WIDTH HEIGHT HARDWARE SET FURN BY INST BY COMMENTS
Exterior
EXTG E1 DOOR - STOREFRONT METAL FRAME DOUBLE - TYPE A 3' - 0"7' - 0"2-A LL LL PER LL SHELL DRAWINGS; BLACK METAL FRAME MT0028 WITH TEMPERED SAFETY
GLAZING
EXTG E2 DOOR - STOREFRONT METAL FRAME SINGLE - TYPE B 6' - 0"7' - 0"3-A LL LL PER LL SHELL DRAWINGS; BLACK METAL FRAME MT0028 WITH TEMPERED SAFETY
GLAZING
2
Interior
10190 01 DOOR - SINGLE FLUSH - 36IN 3' - 0"7' - 0"6 GC GC PAINT. SEE ELEVATION. FRAME COLOR TO MATCH.
10190 02 DOOR - SINGLE FLUSH - 36IN 3' - 0"7' - 0"6 GC GC PAINT. SEE ELEVATION. FRAME COLOR TO MATCH.
2
1 Sign Vinyl Sign: "THIS DOOR MUST REMAIN
UNLOCKED WHEN BUILDING IS OCCUPIED"Seton ---
1 Threshold 325 Half Saddle Threshold National Guard ---
1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626
1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689
1 Operating Trim 108 Door Pull Handle Rockwood 630
1 Securing Devices A08794-003 Adjustable Ring, Mortise Cyl. 516-13/32 Falcon Lock 626
1 Securing Devices C987 7-Pin Mortise Cylinder Housing w/AR Cam Falcon Lock 626
1 Securing Devices C953 7-Pin Rim Cylinder Housing Falcon Lock 626
9 Securing Devices KB632-2 Cut User Key "A" Keyway Falcon Lock ----
1 Securing Devices KB609-2 Cut Control Key "A" Keyway Falcon Lock ---
2 Securing Devices C607 7-Pin Core Combinated "A" Keyway Falcon Lock 626
1 Securing Devices CD35A-NL-OP Panic Device Von Duprin 628/630
3 Hanging Devices TA2314/MPB91 Hinge MacPro Bearing 4.5 x 4.5 McKinney 630
No.Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 2-A - For new single aluminum secondary entry/exit door (50 or more occupancy)
1 Sign Vinyl Sign: "THIS DOOR MUST REMAIN
UNLOCKED WHEN BUILDING IS OCCUPIED"Seton ---
1 Threshold 325 Half Saddle Threshold National Guard ---
2 Accessories Door Sweep 18062CNB36 Pemko A
2 Stops and Holders 473 Door Stop w/Hook Rockwood 626
2 Closing Devices 8916 Door Closer 8916 AF89P AL Dorma 689
2 Operating Trim 48 Push Bar x 31 Rockwood 630
2 Operating Trim 108 Door Pull Handle Rockwood 630
2 Securing Devices (active leaf)A08794-003 Adjustable Ring, Mortise Cyl. 5/16-13/32 Falcon Lock 626
2 Securing Devices (active leaf)C987 7-Pin Mortise Cylinder Housing w/AR Cam Falcon Lock 626
9 Securing Devices (active leaf)KB632-2 Cut User Key "A" Keyway Falcon Lock ---
1 Securing Devices (active leaf)KB609-2 Cut Control Key "A" Keyway Falcon Lock ---
2 Securing Devices (active leaf)C607 7-Pin Core Combinated "A" Keyway Falcon Lock 626
1 Securing Devices (inactive
leaf)MS1880 Two-Point Flushbolt Adams Rite 626
1 Securing Devices (active leaf)MS1850S Deadbolt Adams RIte 626
6 Hanging Devices TA2314/MPB91 Hinge MacPro Bearing 4.5 x 4.5 McKinney 630
No.Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 3-A - For pair aluminum main entry/exit doors (300 or less occupancy)
1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626
3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray
2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630
1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689
1 Securing Devices PB5425LN Lock, Shallow Coin Turn,
Privacy PB5425LN-693-497 1-3/4 Yale Lock 626
3 Hanging Items TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626
No.Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 6 - For restroom door with lever and privacy lock
Revision Schedule
Rev Date By Description
1. INSTALL EXTERIOR FURNITURE THROUGHOUT AS
SHOWN.
2.INSTALL CAFE FURNITURE THROUGHOUT AS SHOWN.
3.NOT USED.
4.CONDIMENT CART. SEE INTERIOR FINISH
ELEVATIONS.
5.PLACE MERCHANDISE FIXTURES PER PLAN.
6.LOCATION OF FIRE EXTINGUISHER.
7.SECURE LOCKERS TO WALL.
8. VENDOR TO INSTALL WATER FILTRATION SYSTEM
PER MANUFACTURER'S REQUIREMENTS. G.C. TO
PROVIDE PLUMBING AND ELECTRICAL
REQUIREMENTS.
9.WATER HEATER LOCATED ABOVE. SEE PLUMBING
DRAWINGS.
10.MANAGERS DESK. SEE MANAGER'S
DESK/EQUIPMENT RACK ELECTRICAL DETAIL FOR
ADDITIONAL INFORMATION.
A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL
REFRIGERATION CONTRACTOR TO CONDUCT INITIAL
FOOD CASE START-UP AND TESTING. FOR LIST OF
APPROVED START UP CONTRACTORS, CONTACT
PROJECT CONSTRUCTION REPRESENTATIVE.
B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND
SEWER SYSTEM UNLESS OTHERWISE NOTED.
C.ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.
D.ALL WOOD SURFACES (DOORS, TRIM, SHELVES,
CABINETS) SHALL BE SEALED.
E. ALL EQUIPMENT AND INSTALLATION WILL MEET
NATIONAL SANITATION FOUNDATION STANDARDS OR
EQUIVALENT.
F.ALL EQUIPMENT AND CABINETRY WILL BE FLUSH
MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE
RAISED TO ALLOW FOR CLEANING.
G.CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES
PER PRODUCT CUT SHEET (E.G. ICE MACHINE).
H.FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO
CASEWORK ELECTRICAL DETAILS.
I. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED
THREADS, EMBELLISHMENTS OR OVERHANGING EDGES
THAT SERVE AS PLACES FOR ACCUMULATION OF DUST,
DIRT AND DEBRIS.
J. WARMING OVEN(S) SHOWN FOR PERMITTING
PURPOSES. INSTALLATION AT STORE OPENING TO BE
VERIFIED BY STARBUCKS CONSTRUCTION
REPRESENTATIVE.
K. EACH HAND WASHING SINK WILL HAVE A SINGLE
SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND
SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING
FAUCET.
L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING
DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO
THE ELECTRICAL DESIGN PLAN.
M.SEE ELEVATIONS FOR DISTRIBUTION OF CUP
DISPENSERS.
N.PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE
APPROVED PLANS FROM THE LOCAL JURISDICTION.
KEYED NOTES GENERAL NOTES
ADJACENT
TENANT
(NO WORK)
I102
1
F 2306323063
F X5050X5050
F TK0027TK0027
F 2287822878
F TK0027TK0027 F 2271822718
F 2184821848 F 2184821848
F 2306323063
F 2144921449 F 2144921449 F 2144921449
F 2184821848
F 2306323063
F 2145621456 F 2184221842
F 2144921449
F TK0057TK0057
F 2300923009
F 2301123011F2180021800
F 2145321453
F 2271822718
F TK0027TK0027
F X1010X1010
F X1011X1011
F X1010X1010
F X1011X1011
F 2012820128
F 2012820128
[2]
[3]
[2]
[4][2]
[2][2]F 2306323063
F 2184821848
F 2144921449
F 2306323063
F 2184821848
F 2144921449
[2][2]
[5][4]
[4]
[3]
[3]
F TK0063TK0063
E 10416
E 10462
E 11083 E 11083 E 13682
E 22212
E 10222
E 13578
E 15186
E 10947
E 10977
E X0009
E 23182
E 18029
E 23338
[10]
[10]
Y 2148621486
[2]
[2]
[4]
[4]
[13]
Y 1214712147
Y 2007320073
Y 2007320073
Y 1214712147
Y 2007320073
Y 1214712147
[2]
1
2
4
5
7
8 9
10
E 10698
E 13834
E 10859
E 10172
E 10099
E 10769
P 22558
E 10862
E 10172
E 10859
E 10099
E 10769
E 10862
P 22558
P 12896
P 12507
P 13082
P 12899
P 12501
P 13076
P 10922
[2]
P 10447
P 13264
P 10804
P 18743
P 10153
P 22642
P 10215
P 13588
P 14688I401
4
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.RESTROOM 1
RESTROOM 2
F TK0051TK0051
F 2008720087
F 2008720087 PATIO
F 1785217852
F 1785217852
DRIVE-THRU
6
[2]
E 10976
E 10976
F 2145621456
E 11130
E 11130
E 11130
F 1435014350
[2]
F TK0053TK0053
F TK0076TK0076
A 10002
F TK0078TK0078A10022
A 10007
F TK0079TK0079
F TK0077TK0077
A 10076
A 10005
A 18744
E 23423
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I101
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
FF & E PLAN
NScale: 1/4" = 1'-0"1 FURNITURE, FIXTURES AND EQUIPMENT PLAN
Revision Schedule
Rev Date By Description
E 10267 E 10267
E 19742E19278
A 10075
E 13330
E 13584
E 10855
E 10091
E 10791
E 10396
E 10858
E 19742
A 10075
E 10267
A 10008
A 10024
A 10028
A 10029
A 10029
A 10029
A 10014
E 16239 E 17255
E 10808
E 22885
E 20032
E 12618
E 12618
A 10075
E 17264
E 23442
E 10267
E 23445
E 23444
E 10267
A 22970
A 23021
[2]
[2]
[2]
[2]
[2]
[2]
[2]
[2]
1
2
3
4
4
[29']
P 10153
P 22768
P 22642
P 11003
P 10153
P 22768
P 22642
P 11003
P 10597
P 10152
P 10549
ENGINE
E 10267
A 14678
A 14677
A 22725
A 10012
A 10029
A 10014
DRIVE-THRU
E 19278
[2]
E 21934
I102
2
E 19278
A 22726
L 22216
E 23420E12508 E 12508
E 22627
E 20010
E 21679
E 17564 E 10267
1.DO NOT BLOCK FOOD CASE INTAKE/EXHAUST.
2.SAFE LOCATED AT POS CABINET. SEE ELECTRICAL
FOR ADDITIONAL INFORMATION.
3.HAND SINK W/ INTEGRAL SPLASH GUARD.
4.INDICATES EQUIPMENT TO BE INSTALLED AT A
FUTURE DATE.
A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL
REFRIGERATION CONTRACTOR TO CONDUCT INITIAL
FOOD CASE START-UP AND TESTING. FOR LIST OF
APPROVED START UP CONTRACTORS, CONTACT
PROJECT CONSTRUCTION REPRESENTATIVE.
B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND
SEWER SYSTEM UNLESS OTHERWISE NOTED.
C.ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.
D.ALL WOOD SURFACES (DOORS, TRIM, SHELVES,
CABINETS) SHALL BE SEALED.
E. ALL EQUIPMENT AND INSTALLATION WILL MEET
NATIONAL SANITATION FOUNDATION STANDARDS OR
EQUIVALENT.
F.ALL EQUIPMENT AND CABINETRY WILL BE FLUSH
MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE
RAISED TO ALLOW FOR CLEANING.
G.CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES
PER PRODUCT CUT SHEET (E.G. ICE MACHINE).
H.FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO
CASEWORK ELECTRICAL DETAILS.
I. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED
THREADS, EMBELLISHMENTS OR OVERHANGING EDGES
THAT SERVE AS PLACES FOR ACCUMULATION OF DUST,
DIRT AND DEBRIS.
J. WARMING OVEN(S) SHOWN FOR PERMITTING
PURPOSES. INSTALLATION AT STORE OPENING TO BE
VERIFIED BY STARBUCKS CONSTRUCTION
REPRESENTATIVE.
K. EACH HAND WASHING SINK WILL HAVE A SINGLE
SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND
SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING
FAUCET.
L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING
DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO
THE ELECTRICAL DESIGN PLAN.
M.SEE ELEVATIONS FOR DISTRIBUTION OF CUP
DISPENSERS.
N.PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE
APPROVED PLANS FROM THE LOCAL JURISDICTION.
KEYED NOTES GENERAL NOTES
E 23419 [2]E 23419 E 23421
A 10075
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I102
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
ENLARGED FF & E PLAN
Scale: 1/2" = 1'-0"1 ENLARGED FF AND E PLAN
N
Revision Schedule
Rev Date By Description
Scale: 3/8" = 1'-0"2 ENLARGED FF&E PLAN - UPPER
1.INSTALL CASEWORK, COUNTERTOPS, SHELVES,
CUBBIES, FINISHES, TRIM AND TABLE TOPS
THROUGHOUT.
2.ALL COUNTERTOPS SHALL BE INSTALLED AT 2'-10"
(860 MM) MAXIMUM A.F.F. MAX.
3.FLOOR DRAIN BELOW. CASEWORK MANUFACTURER
TO COORDINATE DESIGN TO INSURE THIS AREA IS
READILY ACCESSIBLE FOR CLEANING AND FREE OF
COUNTERTOP SUPPORT.
A.GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION
MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS
BETWEEN CASEWORK SHOP DRAWINGS, EXISTING SITE
CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT
FIXTURES. ALL DIMENSIONS SHALL BE FIELD VERIFIED
BY G.C.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE
AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL
CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE
WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS
PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED
DATE OF DELIVERY.
C.STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK
VENDOR TO SUPPLY CASEWORK LISTED IN THE
CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED.
D.CASEWORK VENDOR TO PROVIDE COMPLETE SHOP
DRAWINGS AND INSTALLATION PACKAGE TO GENERAL
CONTRACTOR TO FACILITATE PROPER INSTALLATION.
E. ALL CASEWORK BOX BASES SHALL BE SET AND LEVELED
USING 1/4" (6 MM) NON-ABSORBENT PLASTIC SHIMS
PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR
LOCATION AND TAGGING OF WALL TREATMENTS BY CV
AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR ABOVE BAR SOFFIT
LOCATIONS.
H.REFERENCE PLUMBING AND ELECTRICAL PLANS FOR
PLACEMENT OF ELECTRICAL, DATA AND PLUMBING ON
FRONT AND BACKLINE OF BAR.
KEYED NOTES GENERAL NOTES
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
CAFE
RESTROOM
VEST.RESTROOM 1
RESTROOM 2 WORKROOM
ENGINE
3
3
3
3 1
2 DRIVE-THRU
C 23964
C 20383
I103
2
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I103
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
CASEWORK PLAN
Scale: 1/4" = 1'-0"1 CASEWORK PLAN
Revision Schedule
Rev Date By Description
N
Scale: 1/4" = 1'-0"2 CASEWORK PLAN UPPER
A.REFERENCE LOW VOLTAGE PLAN SHEET AND
ELECTRICAL DRAWINGS.
B.IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR
TO PROVIDE SEMI-RECESSED SPRINKLER HEADS WITH
POLISHED CHROME ESCUTCHEONS CENTERED IN
ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE
REQUIRED IN GWB SOFFIT OVER FRONT BAR,
CONCEAL SUPPLY PIPING WITHIN SOFFIT. GENERAL
CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL
PRIOR TO INSTALLATION.
C.LEAVE TEN (10) ADDITIONAL RETAIL CEILING TILES TO
MATCH RETAIL CEILING PAINT COLOR ABOVE THE
WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
D.PROVIDE GROMMET AT ACOUSTIC CEILING
PENETRATIONS FOR FIXTURES OF SUPPORTS.
E.HEATING, VENTILATING AND AIR CONDITIONING
SHOWN ON THIS PLAN PROVIDED FOR REFERENCE
ONLY. SEE MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
F.DIFFUSERS AND RETURNS IN ACOUSTICAL CEILING TILE
TO BE CENTERED IN TILE AND PAINTED TO MATCH
ADJACENT FINISHES (TYP.).
G.PAINT ALL EXPOSED HVAC DUCTS, HVAC DIFFUSERS,
LIGHT TRIM RINGS, PIPING, CONDUIT AND JUNCTION
BOXES THE SAME COLOR AS SPECIFIED ON
SURROUNDING CEILING OR SOFFIT UNLESS OTHERWISE
NOTED. TYPICAL THROUGHOUT RETAIL AREA OF STORE.
H.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE
STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN
ORDERING PAINTS.
I.DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN
AVAILABLE.
J.DATA CABLING AT EXPOSED CEILING SHALL BE
INSTALLED IN METAL CONDUIT OR PER LOCAL CODE
REQUIREMENT.
KEYED NOTES GENERAL NOTES
1.GWB CEILING. PAINT CEILING DIFFUSERS AS INDICATED.
2.WASHABLE CEILING TILE LOCATED IN BACK OF HOUSE.
3.AIR CURTAIN. REFER TO SPEC FOR EQUIPMENT SIZE.
4.PLATFORM FOR HEATER AND WATER FILTRATION.
PROVIDE SOFFIT ABOVE AND LIFT CEILING THIS AREA
ONLY TO INSURE ADEQUATE CLEARANCE FOR
SERVICING. ALL ENCLOSED SIDES TO RECEIVE FRP.
5.FURNISH AND INSTALL DOOR ACTIVATED AIR CURTAIN
PER JURISDICTIONAL REQUIREMENTS. SEE MECHANICAL
DRAWINGS FOR ADDITIONAL INFORMATION.
6.RECESSED SPEAKER. FINISH COLOR TO BE BLACK OR
PAINT TO MATCH ADJACENT FINISH.
7.EXTERIOR AWNINGS.
8.MOUNT DRIVE THRU CAMERA INSTALLED AT 36" TO 72"
(915MM TO 1830MM) FROM DRIVE THRU WINDOW WITH
CLEAR VIEW OF CUSTOMER AND DRIVE THRU POS.
9.LOCATE SECURITY HEAD UNIT AT MANAGER'S
WORKSTATION.
LEGEND
STRIP LIGHTING
PENDANT LIGHT
RECESSED CAN LIGHT
WALL SCONCE
EXIT SECURITY LIGHT
SUPPLY AIR
RETURN AIR
360° SECURITY CAMERA
TROFFER
MUSIC SYSTEM RECESSED SPEAKER
LINEAR DIFFUSER
C
CEILING TILE START POINT DATUM
ICE CHUTE
NUGGET ICE DISPENSER
NUGGET ICE CHUTE START/END
EXHAUST
ADJACENT
TENANT
(NO WORK)
EQ EQ
EQ EQ
2'
-
8
"
1'
-
7
1
/
4
"
2'
-
5
"
1'
-
1
0
3
/
4
"
1' - 8 1/2"3' - 6"1' - 6"2' - 0"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"1' - 6"2' - 0"3' - 6"3' - 6"1' - 9 1/4"
5'
-
6
"
5'
-
6
"
4'
-
2
"
3'
-
1
0
"
3'
-
7
"
3'
-
1
0
"
3' - 6"2' - 1"
2'
-
9
1
/
4
"
3'
-
6
"
3'
-
6
"
3'
-
8
"
2'
-
0
"
4'
-
0
"
2'
-
0
"
1' - 9"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"2' - 0"
5' - 7"1' - 0"3"
2'
-
5
1
/
2
"
8"
3"
3' - 6"3' - 6"3' - 6"3' - 6"4' - 10"5' - 0 1/2"
2'
-
9
"
1'
-
6
"
1'
-
6
"
1'
-
6
"
2'
-
6
"
2'
-
6
"
1'
-
4
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
2'
-
8
"
3' - 4"2' - 10"
9' - 6"7' - 0"7' - 0"7' - 0"
3' - 11 1/4"9' - 5 1/2"7' - 0"7' - 0"14' - 0"7' - 0"
GYP. CEILING
10' - 0"AFF
PAINTED X7045
CAFE
GYP. CEILING
9' - 0"AFF
PAINTED X7044
RESTROOM 1
GYP. CEILING
9' - 0"AFF
PAINTED X7044
RESTROOM VESTIBULE
GYP. CEILING
9' - 0"AFF
PAINTED X7044
RESTROOM 2
ACT
9' - 0"AFF
WHITE
WORKROOM
GYP. CEILING
10' - 0"AFF
PAINTED X7044
DT BUMP
BEVELED CIRRUS ACT
10' - 6"AFF
MATCHES X7046
CAFE
L 20831[3]
L 15057 [7]
[2]
[2]
L 21772
L 21772
[2]
[2]
L 21772[4]
L 21772[6]
L 21772 [37]
L 21772 [24]
L 22216 [21']
2'
-
2
1
/
4
"
A 22549 A 22549
L X2851 L X2851
1
1
1
1
1
2
4
5
6 6
9
777
7
7
L 22216[31']
EQ
EQ
3' - 2"5' - 6"3' - 6"
L 15057EQEQ
2'
-
5
"
1'
-
1
0
1
/
4
"
L 21772
L 19049
L 190493
3
3
I503
2
I503
5
I503
6
I503
10
I503
10
I503TYP
8
I503
EQ EQ
EQ
EQ
5
I503
1
I5031
I503
1
I503
1
I503
1
I503
F 2248722487 [16]
9
I503
14' - 0"
41' - 11 3/4"
r 1'
-
0
"
T
Y
P
.
3'
-
1
0
"
L 22400[6' 10"]
3'
-
2
"
8
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I104
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
REFLECTED CEILING
PLAN
Scale: 1/4" = 1'-0"1 REFLECTED CEILING PLAN
N
Revision Schedule
Rev Date By Description
1.FLOOR SINK LOCATION. SEE BUILDING FLOOR
PENETRATION PLAN ON SHEET A102 AND PLUMBING FOR
ADDITIONAL INFORMATION.
2.RECESSED ELECTRICAL. SEE BUILDING FLOOR
PENETRATION PLAN ON SHEET A102 AND ELECTRICAL
FOR MORE INFORMATION.
3.WALK-OFF MAT AT ENTRY. SEE INERIOR DETAIL SHEETS
FOR TRANSITION.
4.MOP SINK WHERE INDICATED. SEE PLUMBING PLANS FOR
MORE INFORMATION.
A.WORKROOM TO BE FINISHED PER LOCAL CODE
REQUIREMENTS.
B.FLOORS, WALLS AND CEILING FINISHES IN FOOD
PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC,
NON-ABSORBENT, DURABLE AND EASILY CLEANABLE.
PAINT SHALL BE WASHABLE; SEMI-GLOSS OR
HIGH-GLOSS FINISH.
C. STARBUCKS TO SUPPLY FLOORING AND BASE FOR
FRONT AND BACK OF HOUSE AS NOTED IN SCHEDULES.
GENERAL CONTRACTOR TO INSTALL. GENERAL
CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE
AND INSTALL. GENERAL CONTRACTOR TO SUPPLY AND
INSTALL MORTAR, ADHESIVE, AND GROUT. GENERAL
CONTRACTOR TO INSPECT ALL TILES AND REJECT
DAMAGED OR SUBSTANDARD TILES PRIOR TO
INSTALLATION.
D. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
E.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND
FOOD PREPARATION AREAS SHALL HAVE A 6" COVED
BASE.
KEYED NOTES GENERAL NOTES
4' - 0"
6'
-
0
"
4'
-
0
"
4' - 0"
1
2
1
1
1
1
1
1
1 11
111
1
2
2
2
2
1
1
1
1
2
2
2 3
3
3
3
3
3
3
32
1
7
1
1
1
2 2
2
1
1 1
2
2
2
2
1
12
I501
12
I501
1
1
1
1
1
1
1
4
3 3
2 2
2
ADJACENT TENANT SPACE
8
I501
8
I501
14
I501
5
I501
13
I501
3
I501
3
I501
2
I501
2
I501
7
I501
TYP
1
I501
8
I501
9
I501
9
I501
8
I501
I501
10 TYP
DRIVE-THRUENGINE
CAFE
WORKROOM
RESTROOM
VEST.
RESTROOM 1
RESTROOM 2
4
I501
4
I501
3
I501
INDICATES NEW METAL BASE:
TILE BASE DID: MT0028
WALL BASE LEGEND
INDICATES ECO GRIP BASE
ECO GRIP BASE DID: 197951
2
INDICATES ECO-GRIP FLOORING
DID: 19795
INDICATES EXISTING CONCRETE FLOORING
INDICATES WALK-OFF MAT
HELIX Z2 - WROUGHT IRON
DID 12243
INDICATES SCHLUTER BASE AT TILE WALL3
INDICATES TRANSITION BETWEEN FINISHES
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I105
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
FLOOR FINISH PLAN
Scale: 1/4" = 1'-0"1 FLOOR FINISH PLAN
N
Revision Schedule
Rev Date By Description
I202
4
I201
2
I202 8
I203
4
I202
3
I203
5
1
4 3
I202 61
9
7
2
13
6I4016
I4017
I401 12
13
14
11
3
5
2
8
9
10
5
2
AAA
A
A A
A
A
B B
B
B
B
B
B
B
B
B
B
BB
B
B
A
A A
C
C
C
C
C
CD
D
D
D
D
D
D
D
D
F
F
F
F
F
F
F
F
I502
1
TYP
I502
5
I502
1
I502
3
I502
8
I502
3
I503
7
TYP
I503
4
TYP
SIM
I502
2
SIM
B
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.
RESTROOM 2
RESTROOM 1
DRIVE-THRU
INDICATES FULL HEIGHT WOOD VENEER
PANEL. SEE INTERIOR ELEVATIONS FOR
SPECIFIC APPLICATION TYPE. REFER TO
DETAILS FOR FURTHER INFORMATION.
DID: WD0073 / MAD 200
INDICATES FULL-HEIGHT FRP TO CEILING ABOVE:
DID: 11469
D
C
B
A
INDICATES FULL-HEIGHT WALL PAINT
DID: X7046 SW 7046 AN0NYMOUS
INDICATES FULL-HEIGHT WALL TILE TO CEILING ABOVE:
DID: 22817
F
LEGEND
INDICATES WALL TILE TO HEIGHT PER INTERIOR
ELEVATIONS
DID: 23801
INDICATES FINISH TRANSITION POINT.
INDICATES CORNER GUARD PER FF&E PLAN
A. WORKROOM TO BE FINISHED PER LOCAL CODE
REQUIREMENTS.
B. INSTALL CORNER GUARDS AS INDICATED.
D.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS
UNLESS OTHERWISE INDICATED.
E. REFER TO INTERIOR ELEVATIONS FOR GRAPHICS
LOCATIONS.
F.REFER TO CASEWORK FINISH SCHEDULE FOR
ADDITIONAL INFORMATION
G. GENERAL CONTRACTOR TO PROVIDE AND INSTALL
WORKROOM WALL FINISHES AS INDICATED IN
SCHEDULES.
H. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE
STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN .
ORDERING PAINTS.
I. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS,
UNLESS OTHERWISE NOTED;
-ALL WOOD AND METAL SURFACES SHALL BE
PAINTED SEMIGLOSS, OR EQUAL.
- ALL ACCENT AND TRIM PAINT TO BE SEMIGLOSS.
- ALL WALL AND CEILING PAINTS TO BE EGGSHELL.
GENERAL NOTES
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I106
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
WALL FINISH PLAN
Scale: 1/4" = 1'-0"1 WALL FINISH PLAN
N
Revision Schedule
Rev Date By Description
1.PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN
ON SHEET I103 AND LIGHTING PLAN ON SHEET E102 FOR
ADDITIONAL INFORMATION).
2.INSTALL AIR CURTAIN, SEE MECHANICAL FOR MORE
INFORMATION.
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE,
FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON
SHEET I601.
B.REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED
WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS
UNLESS OTHERWISE INDICATED.
D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS,
UNLESS NOTED OTHERWISE:
1)WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2)ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR
EQUAL.
a.WALL AND CEILING PAINTS TO BE EGGSHELL OR
EQUAL.
3)PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL
BE SEMI-GLOSS OR EQUAL.
E.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE
STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN
ORDERING PAINTS.
F.FLOORS, WALLS AND CEILING FINISHES IN FOOD
PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC,
NON-ABSORBENT, DURABLE AND EASILY CLEANABLE.
PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH
GLOSS FINISH.
G.ALL WOOD SURFACES (DOORS, TRIM, SHELVES,
CABINETRY) SHALL BE SEALED.
H.REFER TO CASEWORK FINISH SCHEDULE ON THE
CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK
FINISH MATERIAL INFORMATION.
I.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND
FOOD PREPARATION AREAS SHALL HAVE A 6" COVED
BASE.
K.ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L.INSTALL BLOCKING AND HANGERS FOR WALL SHELVING
BEFORE INSTALLING BACK BAR TILE.
M.GENERAL CONTRACTOR TO PROVIDE AND INSTALL
WORKROOM WALL FINISHES.
KEYED NOTES GENERAL NOTES
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487 F 2248722487QWD0073QWD0073
BMT0028BMT0028BMT0028
QWD007310
I503
10
I503
10
I503
8
I501
8
I501
8
I501
5
I502
2
I502SIM,
TYP
TYP
6
I502
Z 19459
EQ EQ
L 19049 QWD0073QWD0073
6'
-
0
"
6'
-
0
"
L X2851 L X2851
2
OPEN TO
BEYOND
QMT0028 QWD0073
MAD2005
I501
2
I504
3
I504
F 2248722487F2248722487F2248722487F2248722487 QWD0073PTX7046
QMT0028QMT0028
3
I502
8
I501
6
I502
EQ EQ
L 19049
2
OPEN TO
BEYOND
OPEN TO
BEYOND
6'
-
1
0
"
6'
-
6
"
7'
-
2
"
I504
11
I504
BMT0028 BMT0028 BMT0028
QWD0073
MAD200BWD0073
MAD200
QWD0073
MAD200
10
I503
10
I503
8
I501
8
I501
PT X7046
5
I501
1
6
I503
G 2333123331ASUKA WATANABE CHROMATIC
HACIENDA ALSACIA
2
I503
2
I504
3
I504
QWD0073
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I201
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR FINISH
ELEVATIONS
Scale: 3/8" = 1'-0"1 CAFE 1
Scale: 3/8" = 1'-0"3 CAFE 3
Scale: 3/8" = 1'-0"4 CAFE 4
Scale: 3/8" = 1'-0"2 CAFE 2
Revision Schedule
Rev Date By Description
1. ATTACH MENU BOARDS PER INSTALLATION DETAILS.
2.SHELVING FOR CBE STATION AS SHOWN. G.C. TO
PROVIDE WALL BLOCKING FOR FASTENERS.
3.CUP DISPENSERS. SEE FF & E PLAN ON SHEET I101 FOR
ADDITIONAL INFORMATION.
4.WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW
UNDERSIDE OF COUNTERTOP SUBSTRATE TO BE FRP.
5.TILE START POINT WHERE INDICATED.
6.PENDANT LIGHT FIXTURE (SEE REFLECTED CEILING PLAN
ON SHEET I103 AND LIGHTING PLAN ON SHEET E102 FOR
ADDITIONAL INFORMATION).
7.INSTALL AIR CURTAIN AS REQUIRED PER JURISDICTION.
8.PROVIDE 6" (150MM) MIN. INTEGRAL SPLASHGUARD AT
HAND SINK PER JURISDICTIONAL REQUIREMENTS.
9. ICE DISPENSER ACCESS PANEL BEHIND WOOD PANEL.
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE,
FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON
SHEET I601.
B.REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED
WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS
UNLESS OTHERWISE INDICATED.
D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS,
UNLESS NOTED OTHERWISE:
1)WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2)ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR
EQUAL.
a.WALL AND CEILING PAINTS TO BE EGGSHELL OR
EQUAL.
3)PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL
BE SEMI-GLOSS OR EQUAL.
E.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE
STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN
ORDERING PAINTS.
F.FLOORS, WALLS AND CEILING FINISHES IN FOOD
PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC,
NON-ABSORBENT, DURABLE AND EASILY CLEANABLE.
PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH
GLOSS FINISH.
G.ALL WOOD SURFACES (DOORS, TRIM, SHELVES,
CABINETRY) SHALL BE SEALED.
H.REFER TO CASEWORK FINISH SCHEDULE ON THE
CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK
FINISH MATERIAL INFORMATION.
I.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND
FOOD PREPARATION AREAS SHALL HAVE A 6" COVED
BASE.
K.ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L.INSTALL BLOCKING AND HANGERS FOR WALL SHELVING
BEFORE INSTALLING BACK BAR TILE.
M.GENERAL CONTRACTOR TO PROVIDE AND INSTALL
WORKROOM WALL FINISHES.
KEYED NOTES GENERAL NOTES
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
OPEN TO
BEYOND
QWD0073 Q 23801I506
2
8'
-
6
1
/
2
"
1
8' - 0 1/4"
B 19795B19795 B 19795
1
I506
1
I502
5
I502
11
I501
11
I501
7
I501
7
I501
1
I501
7
I503 TYP
3
I503
5
OPEN TO
BEYONDOPEN TO
BEYOND
B 19795 B 19795
11
I501
11
I501
7
I501
Q 11469
2
3' - 1"1' - 1 1/2"
8
B 19795
Q 23801
11
I501
5
1
I503
B 19795Q23801
7
I502
1
I501
Q 23801
5
1
I503
B 19795
Q 23801
11
I501
7
I501
C X0001
5
1
I503
BMT002811
I501
Q 23801 QWD0073Q23801
B 19795 7
I501
10
I503
8
I501
6
I502
2
452
A501
B 19795
9
1
I503
OPEN TO
BEYOND
B 19795
6
7'
-
2
"
6'
-
1
0
"
6'
-
6
"
BMT0028 B 197955
I501
11
I501
35
I501
5'
-
0
"
QWD0073
BMT0028
10
I503
8
I501
6
I502
3' - 8 1/4"
A 22970 OPEN TO
BEYOND
6
7'
-
2
"
6'
-
1
0
"
6'
-
6
"
5
I501BMT0028 B 19795 11
I501
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I202
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR FINISH
ELEVATIONS
Scale: 3/8" = 1'-0"6 ENGINE 6
Scale: 3/8" = 1'-0"5 ENGINE 5
Scale: 3/8" = 1'-0"9 DRIVE-THRU 3
Scale: 3/8" = 1'-0"8 DRIVE-THRU 2
Scale: 3/8" = 1'-0"7 DRIVE-THRU 1
Scale: 3/8" = 1'-0"4 ENGINE 4
Scale: 3/8" = 1'-0"1 ENGINE 1
Scale: 3/8" = 1'-0"3 ENGINE 3
Scale: 3/8" = 1'-0"2 ENGINE 2
Revision Schedule
Rev Date By Description
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
1.APPROXIMATE LOCATION OF ICE DIVERTER TO BE
CONNECTED TO ICE MACHINE AND CHUTE PER RCP.
2. WALL MOUNT HAND SINK WITH SOAP AND PAPER TOWEL
DISPENSER. G.C. TO PROVIDE BLOCKING FOR
FASTENERS.
3. ICE MACHINE (SEE PLUMBING AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION).
4.MOP SINK. FULL HEIGHT FRP AT ENCLOSURE (SEE
PLUMBING PLANS FOR MORE INFORMATION).
5.WATER HEATER ABOVE (SEE PLUMBING DRAWINGS).
6.MANAGERS DESK. SEE MANAGER'S DESK/EQUIPMENT
RACK ELECTRICAL DETAIL FOR ADDITIONAL
INFORMATION.
7.ELECTRICAL PANELS (SEE ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION).
8.WATER FILTRATION EQUIPMENT (SEE PLUMBING
DRAWINGS).
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE,
FIXTURES, AND EQUIPMENT (FF & E) SCHEDULES ON
SHEET I601.
B.REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED
WITH ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C.CHANGE PAINT COLOR ONLY AT INSIDE CORNERS
UNLESS OTHERWISE INDICATED.
D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS,
UNLESS NOTED OTHERWISE:
1)WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2)ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR
EQUAL.
a.WALL AND CEILING PAINTS TO BE EGGSHELL OR
EQUAL.
3)PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL
BE SEMI-GLOSS OR EQUAL.
E.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE
STARBUCKS NATIONAL ACCOUNT COLOR CODE WHEN
ORDERING PAINTS.
F.FLOORS, WALLS AND CEILING FINISHES IN FOOD
PREPARATION AREAS SHALL BE SMOOTH, NON-TOXIC,
NON-ABSORBENT, DURABLE AND EASILY CLEANABLE.
PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH
GLOSS FINISH.
G.ALL WOOD SURFACES (DOORS, TRIM, SHELVES,
CABINETRY) SHALL BE SEALED.
H.REFER TO CASEWORK FINISH SCHEDULE ON THE
CASEWORK FINISH PLAN ON SHEET I102 FOR CASEWORK
FINISH MATERIAL INFORMATION.
I.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J.ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND
FOOD PREPARATION AREAS SHALL HAVE A 6" COVED
BASE.
K.ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L.INSTALL BLOCKING AND HANGERS FOR WALL SHELVING
BEFORE INSTALLING BACK BAR TILE.
M.GENERAL CONTRACTOR TO PROVIDE AND INSTALL
WORKROOM WALL FINISHES.
N.GENERAL CONTRACTOR TO COORDINATE MECHANICAL,
ELECTRICAL, FIRE ALARM, SECURTY & PLUMBING
TRADES TO AVOID EQUIPMENT / MATERIAL IMPACTING
PROPOSED ART OR FIXTURE INSTALLATIONS.
KEYED NOTES GENERAL NOTES
OPEN TO
BEYOND
Q 19795
Q 11469
2
I501
1' - 6 3/4"Q 11469
Q 19795 2
I501
14
I501
Q 19795
TYP
Q 11469
5
8
43
7
A501
6'
-
1
0
3
/
4
"
7
Q 11469
Q 19795 2
I501
5
4
OPEN TO
BEYOND
Q 11469Q11469Q11469
Q 19795Q19795Q19795Q19795
2'
-
1
0
"
3'
-
8
"
2
I501 TYP
9"
8 1/2"6 3/4"
5'
-
0
"
3' - 8 3/4"
5'
-
6
"
Q 11469
6
2
7'
-
4
3
/
4
"
2' - 5 3/4"
2
I501
Q 11469
Q 19795 2
I501
Q 11469
Q 19795
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I203
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR FINISH
ELEVATIONS
Scale: 3/8" = 1'-0"1 BOH 1
Scale: 3/8" = 1'-0"2 BOH 2
Scale: 3/8" = 1'-0"3 BOH 3
Scale: 3/8" = 1'-0"4 BOH 4
Scale: 3/8" = 1'-0"6 BOH 6
Scale: 3/8" = 1'-0"5 BOH 5
Revision Schedule
Rev Date By Description
A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND
NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
B.ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED
DATUM POINT.
C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE
UNLESS OTHERWISE NOTED.
D.DIAPER CHANGING STATION IS TO BE INSTALLED PER
MANUFACTURER ’S INSTRUCTIONS. UNIT IS TO BE
FASTENED TO STRUCTURE AT ALL SIX CHASSIS
ATTACHMENT POINTS.
E.LOCATE DIAPER CHANGING STATION AS SHOWN TO
ALLOW NECESSARY CLEARANCE FOR OPERATION OF ALL
RESTROOM FIXTURES. LOCATION SHALL NOT IMPEDE
ACCESS, EGRESS, OR DOOR SWING.
F.ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND
CLEARANCES SHALL COMPLY WITH THE ACCESSIBILITY
REQUIREMENTS OF THE LOCAL JURISDICTION.
1.67" (1700MM) ACCESSIBLE TURNING RADIUS.
2.30" (760MM) X 52" (1320MM) CLEAR FLOOR SPACE.
3.WATER CLOSET CLEAR FLOOR SPACE.
4.SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
ALL SENSORS AND CONTROLS (TYPICAL).
5.TILE START POINT . FULL TILE ABOVE BASE COVE.
CENTER FULL TILE ON WALL (HORIZONTALLY).
6.WALL MOUNTED LAVATORY INSTALLED WITH
SUPPORT CARRIER AND INSULATED BOOT AT
EXPOSED PIPES.
7.CENTER MIRROR OVER LAVATORY. MOUNT AT 40"
(1015MM) MAX. TO BOTTOM EDGE OF REFLECTIVE
SURFACE.
8.COAT HOOK. MOUNT AT CENTERLINE OF DOOR.
9.CENTER SCONCE LIGHTING OVER MIRROR (SEE
ELECTRICAL).
10.IN-WALL WOOD BLOCKING. VERIFY BLOCKING
LOCATION, EXTENTS AND BLOCKING WITH
MANUFACTURER'S REQUIREMENTS.
KEYED NOTES GENERAL NOTES
2' - 0"1' - 0"
3' - 0"
2'
-
9
"
1'
-
5
3
/
4
"
1' - 6"
2'
-
9
"
1'
-
7
"
3'
-
5
"
1'
-
6
"
3' - 3"
6"4' - 0"
3' - 3 1/2"5 1/4"
1' - 6 1/4"
2'
-
3
"
2'
-
9
"
1'
-
6
"
4"
..
3'
-
3
"
2'
-
9
"
DIAPER
CHANGING STATION SIDE AND FRONT ELEVATIONS
ELECTRIC HAND
DRYER FRONT ELEVATION
4'
-
0
"
HAND SINK
FRONT ELEVATION
COAT
HOOK ELEVATION
HAND SINK
SIDE ELEVATION
TOILET
FRONT ELEVATION
TOILET
SIDE ELEVATION
INSTALL HEIGHT PER
MANUFACTURER'S
INSTRUCTION
3'
-
6
"
I4016
I4017
I401 12
13
14
113
5
2
8
9
10
RESTROOM
VEST.RESTROOM 1
RESTROOM 2
11
1
2
3
3
E 10172
E 10859
E 10769
E 10099
E 10976
E 10862
F 1435014350
F 1435014350
F 1075610756
F 1075610756
E 10862
E 10859
E 10976
E 10769
E 10099
E 10172
7
7
8
8
OPEN TO
BEYOND
BMT0028
PT X7046
9"
BMT0028
PT X7046
PT X7046
PT X7046
4
I501
BMT0028
PT X7046
PT X7046
PT X7046
4
I501
Q 22823
BMT0028
6'
-
1
0
"
EQ EQ
7
9
6
L 20750
[2]
5
CENTER START
TILE WITH
LAVATORY.
[2]
13
I501
F 1435014350
Q 22823
5
TYP3
I501
10
Q 22823
5
PT X7046
PT X7046
Q 22823
5
4 8
Q 22823
5
10
Q 22823
5
3
I501 TYP
10
Q 22823
PT X7046
PT X7046
5
4 8
Q 22823
5
Q 22823
10
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I401
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
RESTROOM PLAN &
ELEVATIONS
Scale: 3/8" = 1'-0"1 MOUNTING HEIGHTS FOR RESTROOM ACCESSORIES
Scale: 1/2" = 1'-0"4 ENLARGED RESTROOM PLAN
Scale: 3/8" = 1'-0"5 VESTIBULE - NORTH
Scale: 3/8" = 1'-0"3 VESTIBULE - EAST
Scale: 3/8" = 1'-0"2 VESTIBULE - SOUTH
Scale: 3/8" = 1'-0"6 VESTIBULE - WEST
Scale: 3/8" = 1'-0"11 RESTROOM 1 - SOUTH
Scale: 3/8" = 1'-0"13 RESTROOM 1 - NORTH
Scale: 3/8" = 1'-0"14 RESTROOM 1 - WEST
Scale: 3/8" = 1'-0"12 RESTROOM 1 - EAST
Scale: 3/8" = 1'-0"7 RESTROOM 2 - WEST
Scale: 3/8" = 1'-0"10 RESTROOM 2 - NORTH
Scale: 3/8" = 1'-0"9 RESTROOM 2 - EAST
Scale: 3/8" = 1'-0"8 RESTROOM 2 - SOUTH
N
Revision Schedule
Rev Date By Description
WALL TILE PER SCHEDULE.
ADHERE TO WALL PER
MFR'S RECOMMENDATIONS
WALL TYPE PER LEGEND
FLOOR FINISH PER
SCHEDULE
SCHLUTER COVE-SHAPED
PROFILE FOR FLOOR/WALL
TRANSITIONS
ECO-GRIP BASE
CAP. COLOR TO
MATCH ECO-GRIP
FLOORING
ECO-GRIP
EPOXY
ADHESIVE
ECO-GRIP
SEALANT
ECO-GRIP
FLOORING
1/4"
(6MM)
ROUTED
COVE
STAINLESS STAPLE
OR POWDER COATED
FASTENER
WALL AND
SHEATHING
PER PLAN
WALL TILE PER PLAN
THINSET
CONCRETE
SLAB
ECO-GRIP
FLOORING
ECO-GRIP
SEALANT
ECO-GRIP BASE
CAP. COLOR TO
MATCH ECO-GRIP
FLOORING
STAINLESS STAPLE
OR POWDER COATED
FASTENER
CABINET FINISH
FACE
INSTALL CASEWORK
BASE PRIOR TO
ECO-GRIP FLOORING
ECO-GRIP
EPOXY
ADHESIVE 1/4" (6MM)
ROUTED
COVE
CONCRETE SLAB
6"
(
1
5
0
M
M
)
M
I
N
.
WALL AND
SHEATHING
PER PLAN
ECO-GRIP
EPOXY
ADHESIVE
ECO-GRIP
SEALANT
ECO-GRIP
FLOORING
CABINET
LEG
1/4" (6MM)
ROUTED
COVE
ECO-GRIP BASE
CAP. COLOR TO
MATCH ECO-GRIP
FLOORING
STAINLESS STAPLE
OR POWDER COATED
STEEL FASTENER
CABINET
ABOVE
CONCRETE
SLAB
6"
(
1
5
0
M
M
)
M
I
N
.
ECO-GRIP
FLOORING
ECO-GRIP BASE CAP.
COLOR TO MATCH
ECO-GRIP FLOORING
STAINLESS STAPLE
OR POWDER COATED
STEEL FASTENER
BAR DIEWALL
INSTALL CASEWORK
DIEWALL PRIOR TO
ECO-GRIP FLOORING
ECO-GRIP EPOXY
ADHESIVE
1/4" (6MM)
ROUTED
COVE
BAR FINISH
PANEL
CONCRETE SLAB
6"
(
1
5
0
M
M
)
M
I
N
.
PLASTIC SHIM
REQUIRED - 1/4" MIN.2"
ECO-GRIP
SEALANT
FLOORING PER
SCHEDULE
6" (150MM) METAL BASE
PER SCHEDULE. ADHERE
TO WALL PER MFR'S
RECOMMENDATION.
CLEAR SILICONE SEALANT
ALUMINUM DOWEL
SECURED INTO SUB
FLOOR & DIEWALL
6"
CAFE BAR NOTE:
ALL COMPONENTS
FURNISHED BY
OTHERS AND
INSTALLED BY G.C.
UNLESS NOTED
OTHERWISE.
ECO-GRIP BASE
CAP. COLOR TO
MATCH ECO-GRIP
FLOORING
ECO-GRIP
EPOXY
ADHESIVE
ECO-GRIP
SEALANT
ECO-GRIP
FLOORING
1/4"
(6MM)
ROUTED
COVE
STAINLESS STAPLE
OR POWDER COATED
FASTENER
FRP WALL
COVERINGWALL AND
SHEATHING
PER PLAN
CONCRETE
SLAB
ECO-GRIP EPOXY
ADHESIVE
ECO-GRIP
FLOORING
1/4" (6MM) ECO-GRIP
SPEEDFLEX
MOP SINK
CONCRETE SLAB
.
ECO-GRIP
FLOORINGECO-GRIP
EPOXY
ADHESIVE 1/4" (6MM)
ROUTED COVE
INSTALL CASEWORK BASE PRIOR
TO ECO-GRIP FLOORING
6" (150MM) +/- TYP. A.F.F.
CABINET TOE-KICK OVERHANG
CONCRETE SLAB
ECO-GRIP BASE CAP. COLOR TO
MATCH ECO-GRIP FLOORING
STAINLESS STAPLE OR POWDER
COATED FASTENER
ECO-GRIP
SEALANT
SEALANT TO MATCH
ADJACENT WALL FINISH
6" (150MM) METAL BASE
PER SCHEDULE. ADHERE
TO WALL PER MFR'S
RECOMMENDATION.
CLEAR SILICONE SEALANT
FINISH FLOOR PER SCHEDULE
1/
4
"
ALUMINUM TRIM AT BOTTOM
OF PANELS
WOOD PANEL, REFER TO
ELEVATION FOR PANEL TYPES
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
WALL TYPE PER PLAN
SEALANT TO MATCH
ADJACENT WALL FINISH
6" (150MM) METAL BASE
PER SCHEDULE. ADHERE
TO WALL PER MFR'S
RECOMMENDATION.
CLEAR SILICONE SEALANT
FINISH FLOOR PER SCHEDULE
CONCRETE SLAB
WALL TYPE PER LEGEND
SEALANT TO MATCH
ADJACENT WALL FINISH
6" (150MM) METAL BASE
PER SCHEDULE. ADHERE
TO WALL PER MFR'S
RECOMMENDATION.
CLEAR SILICONE SEALANT
FINISH FLOOR PER SCHEDULE
WALL TYPE
PER PLAN
1/
4
"
WALL TILE PER SCHEDULE
WATERPROOF MEMBRANE
ON WOOD SUBFLOOR ONLY
STOREFRONT DOOR WITH THRESHOLD
WALK-OFF MAT PER SCHEDULE
METAL REDUCER STRIP
AT ALL EDGES. ADHERE
AND MECHANICALLY
FASTEN TO SUBSTRATE
PER MFR'S
RECOMENDATION
PER WALK-OFF
MAT MFR.
.
SEALED CONCRETE
FLOOR
CONCRETE
SLAB
FLOOR SINK
GRATE
FLOOR SINK FLANGE,
SET ABOVE ECO GRIP
1/
4
"
(
6
M
M
)
T
Y
P
.
ECO-GRIP
FLOORING
ECO-GRIP EPOXY
ADHESIVE
ECO-GRIP
COLOR MATCHED SPEEDFLEX
ECO-GRIP
FLOORING
ECO-GRIP EPOXY
ADHESIVE
16 GA. 2 1/4" (57MM)
WIDE STAINLESS STEEL
TRANSITION STRIP
SEALED
CONCRETE
FLOOR
STAINLESS
FASTENER
LEAD ANCHOR
ROUTE OUT
FLOORING TO DEPTH
OF TRANSITION STRIP
SEALANT
.
1/4" (6MM) TYP.
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I501
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR DETAILS -
FLOOR
Scale: 6" = 1'-0"3 SCHLUTER COVED BASE
Scale: 6" = 1'-0"1 ECO-GRIP - BASE AT TILED WALL
Scale: 6" = 1'-0"6 ECO-GRIP BASE AT CABINET SIDE
Scale: 6" = 1'-0"7 ECO-GRIP BASE AT CABINET WITH LEGS
Scale: 6" = 1'-0"5 FINISH PANEL - 6" BASE
Scale: 6" = 1'-0"2 ECO-GRIP BASE CAP WITH FRP
Scale: 12" = 1'-0"14 ECO-GRIP AT MOP SINK
Scale: 6" = 1'-0"11 ECO-GRIP BASE AT CABINET FRONT
Scale: 6" = 1'-0"12 STOREFRONT MOUNT WALK OFF MATT
Scale: 12" = 1'-0"10 ECO-GRIP TO FLOOR SINK TRANSITION
Scale: 12" = 1'-0"9 ECO-GRIP TO CONCRETE TRANSITION
Revision Schedule
Rev Date By Description
Scale: 6" = 1'-0"8 METAL BASE AT WOOD PANEL
Scale: 6" = 1'-0"4 METAL BASE AT WALL
Scale: 6" = 1'-0"13 METAL BASE AT TILE
CLEAR SILICONE, TYP
HEIGHT PER ELEVATION
EXISTING WALL
WALL TILE PER SCHEDULE
WINDOW SILL PER
SCHEDULE
WOOD PANEL, REFER TO ELEVATION
FOR PANEL TYPES
WALL TYPE PER LEGEND
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
PLYWOOD SUBSTRATE, PAINT MATT BLACK
WHERE VISIBLE
1/
4
"
WALL TYPE PER
FLOOR PLAN
WOOD PANEL (WD0073)
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
PLYWOOD SUBSTRATE,
PAINT MATT BLACK
WHERE VISIBLE
SCHLUTER-JOLLY EMBEDDED
IN GROUT
WALL TILE PER SCHEDULE
CEMENTITOUS BACKER
BOARD
1/4"
WALL TYPE PER FLOOR PLAN
WOOD PANEL (WD0073)
METAL INLET AT MITER CORNER
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
PLYWOOD SUBSTRATE,
PAINT MATT BLACK
WHERE VISIBLE
EXISTING STOREFRONT WINDOW SYSTEM
I502
5
SIMBACKER ROD AND CAULKING
BETWEEN WOOD AND WINDOW
MULLION
EXISTING WALL CONSTRUCTION
WOOD PANEL (WD0073)
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
PLYWOOD SUBSTRATE, PAINT
MATT BLACK WHERE VISIBLE
METAL MT0028 END
CAP. ADHERE TO WALL
AND MECHANICALLY
FASTEN AS REQUIRED.
METAL ANGLE TRIM
WOOD PANEL
TILE
WALL TYPE AND
SHEATHING PER
BUILDING FLOOR
PLAN
SCHLUTER-JOLLY EMBEDDED
IN GROUT
WALL TILE PER SCHEDULE
CEMENTITOUS BACKER
BOARD
WALL TYPE PER LEGEND
WOOD PANEL (WD0073)
METAL INLET AT MITER CORNER
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
PLYWOOD SUBSTRATE,
PAINT MATT BLACK
WHERE VISIBLE
WALL TYPE PER FLOOR PLAN
WOOD PANEL (WD0073)
PANEL MOUNTED WITH ALUMINUM Z-
CLIPS SPACED PER MFR
RECOMMENDATION
PLYWOOD SHEATHING
FRP AS SCHEDULED
MARLITE F570 EDGE TO MATCH FRP
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I502
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR DETAILS -
WALL
Scale: 6" = 1'-0"7 TILE WALL TO WINDOW SILL TRANSITION
Scale: 6" = 1'-0"6 WOOD PANEL REVEAL
Scale: 6" = 1'-0"3 WOOD PANEL INSIDE CORNER
Scale: 6" = 1'-0"5 WOOD PANEL OUTSIDE CORNER
Scale: 6" = 1'-0"1 WOOD PANEL @ STOREFRONT WINDOW
Scale: 3" = 1'-0"4 WOOD SLAT CORNER DETAIL
Scale: 6" = 1'-0"2 TILE TO WOOD TRANSITION
Revision Schedule
Rev Date By Description
Scale: 6" = 1'-0"8 WOOD PANEL TO FRP OUTSIDE CORNER
CLEAR SEALANT
METAL STARTER STRIP
EMBEDDED IN GROUT
CEMENTITOUS BACKER
BOARD
WALL TILE PER SCHEDULE
WALL TYPE PER LEGEND
MA
X
1/
4
"
GYP CEILING
PER RCP
LED STRIP PER RCP
GYP
4"
WALL TYPE PER FLOOR PLAN
5/8" GYP PAINTED PER RCP
FUR OUT TO ACHIEVE DIMENSIONED
DEPTH
SUBSTRATE TO BE PAINTED
SW7020 BLACK FOX
PANEL MOUNTED WITH
ALUMINUM Z-CLIPS
WOOD PANEL, REFER TO
ELEVATION FOR PANEL TYPES
3/
4
"
7'-6" AFF
GYP WALL
GYP CEILING PER RCP
GYP CEILING PER RCP
WALL TYPE PER FLOOR PLAN
CEMENTITOUS BACKER BOARD
WALL TILE PER SCHEDULE
WALL TILE PER SCHEDULE
WALL TYPE PER FLOOR PLAN
METAL SCHLUTER JOLLY
EMBEDDED IN GROUT
WALL TILE PER SCHEDULE
CEMENTITOUS BACKER BOARD
WALL TILE PER SCHEDULE
LED STRIP PER RCP
PAINTED GYP PER
ELEVATIONS/RCP
4"
WALL TYPES PER
FLOOR/FRAMING
PLANS
PER RCP
ARTWORK INSTALLED AS WALLCOVERING
PER SCHEDULE. APPLY TO WALL PER
MFR'S RECOMMENDATION
ALUMINUM "J" MOULDING.
COLOR TO MATCH
WALLCOVERING
4"
7'-6" AFF
PER RCP
PER RCP
GYP. BOARD, PAINT PER RCP
GYP. BOARD, PAINT PER RCP
2' X 4' ACT CEILING PER RCP
ARMSTRONG CIRRUS 6X48
MATCH PAINT SW7047
WOOD TRIM, NAILED IN
PLACE, HOLES FILLED
AND PUTTIED TO
CONCEAL NAILS.
GYP CEILING PAINTED
PER RCP
6"
HEIGHT PER RCP
HEIGHT PER RCP
PLYWOOD BLOCKING
TO SECURE TRIM
ALIGN
2"
CLEAR SEALANT
METAL STARTER STRIP
EMBEDDED IN GROUT
CEMENTITOUS BACKER
BOARD
WALL TILE PER SCHEDULE
WALL TYPE PER LEGEND
MA
X
1/
4
"
CEILING PER RCP
CLEAR SEALANT
METAL STARTER STRIP
EMBEDDED IN GROUT
CEMENTITOUS BACKER
BOARD
WALL TILE PER SCHEDULE
WALL TYPE PER LEGEND
MA
X
1/
4
"
GYP CEILING
PER RCP
LED STRIP PER RCP
GYP
4"
GYP CEILING
PER RCP
7'-6" AFF
GYP SOFFIT
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I503
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR DETAILS -
WALL/CEILING
Scale: 3" = 1'-0"3 LIGHT COVE AT BACKBAR TILE
Scale: 6" = 1'-0"10 WOOD PANEL TOP AT CEILING
Scale: 1 1/2" = 1'-0"6 HEADER @ RESTROOM VESTIBULE
Scale: 6" = 1'-0"4 TILE TO TILE INSIDE CORNER
Scale: 6" = 1'-0"7 TILE TO TILE OUTSIDE CORNER
Revision Schedule
Rev Date By Description
Scale: 3" = 1'-0"2 4" LIGHT COVE @ WALLCOVERING
Scale: 1 1/2" = 1'-0"5 SOFFIT TRANSITION
Scale: 3" = 1'-0"8 RECESSED ACT AT CAFE
Scale: 6" = 1'-0"1 TILE AT CEILING
Scale: 3" = 1'-0"9 BACKBAR TILE HEADER
FACE OF
WALL
ELEVATION VIEW - BACKING
PLAN VIEW - ELECTRICAL COMPONENTS
PLAN VIEW
(3
9
0
M
M
)
1'
-
3
1
/
4
"
(1
8
0
M
M
)
7"
(T
Y
P
.
)
3"
(
7
5
M
M
)
CLEATS FASTENED TO
PLYWOOD BACKER
(205MM)
8"BANQUETTE WIDTH VARIES
(205MM)
8"
(8
4
5
M
M
)
2'
-
9
1
/
4
"
TOP OF
FINISHED
FLOOR
3/4" PLYWOOD
BACKER TO BE
INSTALLED
BEHIND WALL
FINISH BY G.C.
FASTENED TO
STRUCTURE
BEYOND
(1
3
0
M
M
)
5"
EQ EQ
BANQUETTE LENGTH VARIES
DUPLEX OUTLET
FOR BANQUETTE
POWER OUTLET.
VERIFY OUTLET
QUANTITY PER
FF&E SCHEDULE.
EDGE OF
BANQUETTE
CONVENIENCE
OUTLET BUILT
INTO BANQUETTE
FRAME
FACE OF
WALL
EDGE OF BASE
BELOW
SHROUD/SPLASH FINISH TO
MATCH COUNTERTOP, TYP.
1 1/2"
6"
COVE DETAIL ON
THIS SIDE ONLY
34" MAX. A.F.F.
CORIAN
COUNTERTOP
NOTE:
ALL COMPONENTS
FURNISHED BY
OTHERS AND
INSTALLED BY G.C.
UNLESS NOTED
OTHERWISE.
34" MAX. AFF
METAL ANGLE,
TYP.
COUNTERTOP
SUBSTRATE
ALUM. Z-CLIPS, TYP.
FINISH PANEL
DIEWALL
COUNTERTOP
OPTIONAL LED STRIP
LIGHTING BY OTHERS
VARIES
MI
N
.
1/
2
"
4" (TYP.)
NOTE:
ALL COMPONENTS
FURNISHED BY
OTHERS AND
INSTALLED BY G.C.
UNLESS NOTED
OTHERWISE.
4
"
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I504
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR DETAILS -
WALL/CEILINGScale: 3/4" = 1'-0"1 BANQUETTE - WALL FLOWER- ELECTRICAL
Scale: 6" = 1'-0"2 ESP SHROUD - CORIAN
Scale: 6" = 1'-0"3 FINISH PANEL - BUILT-UP COUNTERTOP OVERHANG
Revision Schedule
Rev Date By Description
.
3/4" CLEAR AT ONE END IN EACH DIRECTION.
DO NOT FASTEN THIS END TO THE CLOSURE
ANGLE. AT OTHER END IN EACH DIRECTION,
FASTEN TEES TO CLOSURE ANGLE.
HANGAR WIRE AT EACH PERIMETER
MAIN TEE AND PERIMETER CROSS TEE
GRID SUSPENSION SYSTEM
FASTEN TO STRUCTURE PER CISCA 3-4
(FIGURES 2, 3, 4, AND 5) AS MODIFIED BY
ASCE 7-05. SECTION 13.5.6.2.2
12 GAGE MINIMUM HANGAR
WIRES AT 4'-0" OC EACH
DIRECTION - NO MORE THAN 1:6
OUT-OF-PLUMB, TYPICAL
WIRE LOOPED AND WRAPPED
AROUND ITSELF 3 TIMES MINIMUM
AT EACH END OF HANGAR WIRE
WITHIN A 3" MAXIMUM LENGTH
WHERE HANGAR WIRES
ARE MORE THAN 1:6 OUT-
OF-PLUMB, PROVIDE
COUNTER-SLOPING WIRES
METAL-FRAMED TRAPEZE
AS NECESSARY TO AVOID
OBSTRUCTIONS
MAINTAIN HANGAR WIRE
SPACING AND CAPACITY
BELOW OBSTRUCTION
5/8" GYPSUM BOARD
LIGHT FIXTURES WEIGHING LESS
THAN 10 POUNDS SHALL BE
CONNECTED TO STRUCTURE ABOVE
BY (1) 12 GAGE TAUT OR SLACK WIRE
LIGHT FIXTURES WEIGHING MORE THAN 10
POUNDS AND LESS THAN 56 POUNDS, AND
AIR TERMINALS / SERVICES WEIGHING
MORE THAN 20 POUNDS AND LESS THAN 56
POUNDS SHALL BE CONNECTED TO
STRUCTURE ABOVE BY (2) 12 GAGE TAUT
OR SLACK WIRES ATTACHED AT DIAGONAL
CORNERS.LIGHT FIXTURES AND AIR TERMINALS /
SERVICES WEIGHING MORE THAN 56 POUNDS
AND ALL PENDANT LIGHT FIXTURES SHALL BE
SUPPORTED DIRECTLY FROM STRUCTURE
ABOVE USING APPROVED HANGARS
LIGHT FIXTURES, AIR TERMINALS, AND SERVICES
SHALL BE POSITIVELY ATTACHED TO THE CEILING
SYSTEM
2 X 2 SHEET METAL ANGLE
CLCL
8" MAX
EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF
MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION
SHALL BE INDEPENDENTLY SUPPORTED AND BRACED FROM
STRUCTURE
GYPSUM BOARD CONSTRUCTION SHALL COMPLY WITH ADDITIONAL PROVISIONS OF SBC SECTION 2508.
METAL SUSPENSION SYSTEM SHALL CONFORM WITH ASCE 7, SECTION 13.5.6.2.1, ASTM C635, ASTM C636,
ASTM C754, AND CISCA 3-4.
NOT REQUIRED IN SEISMIC DESIGN CATAGORY
C FOR CEILINGS LESS THAN 144 SF
A PERIMETER SUPPORT B GENERAL SUPPORT
C LIGHT FIXTURE AND MECHANICAL SERVICE SUPPORT
FOUR 12 GAGE MINIMUM WIRES SPLAYED 90 DEGREES
(IN PLAN) FROM EACH OTHER AND SECURED TO MAIN
RUNNER WITHIN 2" OF INTERSECTION. EACH END OF
EACH WIRE TO BE LOOPED AND WRAPPED AROUND
ITSELF 3 TIMES MINIMUM WITHIN A 3" MAX LENGTH.
.FOR SPANS UP TO 6'-0", USE A SINGLE 20 GAGE 1 5/8"
COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8
SCREWS AND TO STRUCTURE WITH (2) HILTI X-DNI .145 DIA X 3/4"
FOR SPANS UP TO 9'-0", USE DOUBLE COMPRESSION STRUT
4
5
°
M
A
X
45° M
A
X
45
°
M
A
X
45
°
M
A
X
LOCATE BRACING AT 12'-0" OC EACH
DIRECTION AND WITHIN 6'-0" OF PERIMETER
WALLS, PARTITIONS, OR EXPANSION JOINTS
E
LATERAL BRACING REQUIRED IF ANY OF THE FOLLOWING EXISTS:
-GYPSUM BOARD CEILING THAT EXTENDS WALL-TO-WALL EXCEEDS 1000 SF
-GYPSUM BOARD CEILING THAT DOES NOT EXTEND WALL-TO-WALL EXCEEDS 144 SF
CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE LATERAL
BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1
SEISMIC DESIGN CATEGORY C: PROVIDE FLEXIBLE
CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO
MOVE 3/8" IN ALL HORIZONTAL DIRECTIONS
SEISMIC DESIGN CATEGORY D, E, ANF F: PROVIDE FLEXIBLE
CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO
MOVE 1" IN ALL HORIZONTAL DIRECTIONS.
F EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF
D SPRINKLER HEAD CLEARANCE
NOT REQUIRED IN SEISMIC DESIGN CATEGORY C
PROVIDE CEILING EXPANSION JOINTS
AS NECESSARY, DIVIDING CEILING INTO
AREAS NO GREATER THAN 2500 SF
CL8" MAX EACH SIDE
2"
.
3/4" CLEAR AT ONE END IN EACH DIRECTION.
DO NOT FASTEN THIS END TO THE CLOSURE
ANGLE. AT OTHER END IN EACH DIRECTION,
FASTEN TEES TO CLOSURE ANGLE.
HANGAR WIRE AT EACH PERIMETER MAIN
TEE AND PERIMETER CROSS TEE
STABILIZER BAR TO MAINTAIN PERIMETER
TEE SPACING
MAIN TEE OR CROSS TEE (SUSPENSION
SYSTEM) HEAVY DUTY
FASTEN TO STRUCTURE PER CISCA 3-4
(FIGURES 2, 3, 4, AND 5) AS MODIFIED BY
ASCE 7-05. SECTION 13.5.6.2.2
12 GAGE MINIMUM HANGAR
WIRES AT 4'-0" OC EACH
DIRECTION - NO MORE THAN
1:6 OUT-OF-PLUMB, TYPICAL
WIRE LOOPED AND WRAPPED
AROUND ITSELF 3 TIMES
MINIMUM AT EACH END OF
HANGAR WIRE WITHIN A 3"
MAXIMUM LENGTH
WHERE HANGAR WIRES
ARE MORE THAN 1:6 OUT-
OF-PLUMB, PROVIDE
COUNTER-SLOPING
WIRES
METAL-FRAMED TRAPEZE
AS NECESSARY TO AVOID
OBSTRUCTIONS
MAINTAIN HANGAR WIRE
SPACING AND CAPACITY
BELOW OBSTRUCTION
ACOUSTICAL CEILING PANELS
LIGHT FIXTURES WEIGHING LESS THAN 10
POUNDS SHALL BE CONNECTED TO STRUCTURE
ABOVE BY (1) 12 GAGE TAUT OR SLACK WIRE
LIGHT FIXTURES WEIGHING MORE THAN 10
POUNDS AND LESS THAN 56 POUNDS, AND AIR
TERMINALS / SERVICES WEIGHING MORE THAN 20
POUNDS AND LESS THAN 56 POUNDS SHALL BE
CONNECTED TO STRUCTURE ABOVE BY (2) 12
GAGE TAUT OR SLACK WIRES ATTACHED AT
DIAGONAL CORNERS
LIGHT FIXTURES AND AIR TERMINALS / SERVICES
WEIGHING MORE THAN 56 POUNDS AND ALL
PENDANT LIGHT FIXTURES SHALL BE SUPPORTED
DIRECTLY FROM STRUCTURE ABOVE USING
APPROVED HANGARS
LIGHT FIXTURES, AIR TERMINALS, AND SERVICES SHALL
BE POSITIVELY ATTACHED TO THE CEILING SYSTEM
2 X 2 CLOSURE ANGLE, MINIMUM. SEE
NOTE AT TOP
CLCL
8" MAX
EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF
MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SHALL
BE INDEPENDENTLY SUPPORTED AND BRACED FROM STRUCTURE
COMPLY WITH ADDITIONAL PROVISIONS OF ASTM C635,
ASTM C636, CISCA 3-4, AND ASCE 7-05, SECTION 13.5.6.
NOT REQUIRED IN SEISMIC DESIGN CATAGORY
C FOR CEILINGS LESS THAN 144 SF
A PERIMETER SUPPORT B GENERAL SUPPORT
C LIGHT FIXTURE AND MECHANICAL SERVICE
SUPPORT
FOUR 12 GAGE MINIMUM WIRES SPLAYED 90
DEGREES (IN PLAN) FROM EACH OTHER AND
SECURED TO MAIN RUNNER WITHIN 2" OF
INTERSECTION. EACH END OF EACH WIRE TO BE
LOOPED AND WRAPPED AROUND ITSELF 3 TIMES
MINIMUM WITHIN A 3" MAX LENGTH.
FOR SPANS UP TO 6'-0", USE A SINGLE 20 GAGE 1 5/8"
COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8
SCREWS AND TO STRUCTURE WITH (2) HILTI X-DNI .145 DIA X 3/4".
FOR SPANS UP TO 9'-0", USE DOUBLE COMPRESSION STRUT.
PROVIDE CEILING EXPANSION JOINTS
AS NECESSARY, DIVIDING CEILING INTO
AREAS NO GREATER THAN 2500 SF.
SEISMIC DESIGN CATEGORY C: PROVIDE FLEXIBLE
CONNECTION TO SPRINKLER HEAD THAT ALLOWS
CEILING TO MOVE 3/8" IN ALL HORIZONTAL
DIRECTIONS.
SEISMIC DESIGN CATEGORY D, E, ANF F: PROVIDE
FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT
ALLOWS CEILING TO MOVE 1" IN ALL HORIZONTAL
DIRECTIONS.
4
5
°
M
A
X
45° M
A
X
45
°
M
A
X
45
°
M
A
X
LOCATE BRACING AT 12'-0" OC EACH
DIRECTION AND WITHIN 6'-0" OF PERIMETER
WALLS, PARTITIONS, OR EXPANSION JOINTS
CL
8" MAX
MAIN
T
E
E
E LATERAL BRACING FOR CEILINGS EXCEEDING 144 SF F EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF
D SPRINKLER HEAD CLEARANCE
CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE
LATERAL BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1
NOT REQUIRED IN SEISMIC DESIGN CATEGORY C
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I505
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR DETAILS -
SUSPENDED CEILINGScale: 1 1/2" = 1'-0"1 SUSPENDED GYP BD CEILING - IBC SEISMIC CATEGORY C, D, E, F
Scale: 1 1/2" = 1'-0"2 SUSPENDED ACOUSTICAL CEILING SYSTEM - IBC DESIGN CATEGORY C, D, E, F
Revision Schedule
Rev Date By Description
BULKHEAD/SOFFIT FRAMING
WOOD CLADDING
DIGITAL MENU DISPLAY SCREENS,
PER SCHEDULE
DISPLAY SCREEN BRACKET, PER
SCHEDULE. BRACKET AFFIXED TO
WALL PER MANUFACTURES
RECOMMENDATIONS AND
REQUIREMENTS DIRRECTLY OVER
THE TOP OF WOOD SLAT PANELS.
BULKHEAD/SOFFIT FRAMING. PROVIDE
IN-WALL BLOCKING FOR DISPLAY
SCREEN BRACKETS PER
MANUFACTURES RECOMMENDATIONS
AND REQUIREMENTS.
MI
N
.
B
L
O
C
K
I
N
G
(
V
I
F
)
3'
-
1
1
/
4
"
(
9
2
0
M
M
)
(2
3
0
M
M
)
6"
CENTER OF MENU BOARDS AT
7' - 4" (2235MM) A.F.F. MIN.,
8' - 6" (2590MM) A.F.F. MAX.
SEE INTERIOR ELEVATIONS
FOR ACTUAL DIMENSION
3/4" PLYWOOD BACKING
BEHIND WALL FINISH,
SECURED TO STRUCTURE
METAL RECESSED CABLE
MANAGEMENT AND POWER
STORAGE BOX. MINIMUM (1)
RECEPTACLES AND (1) DATA
PORT PER SCREEN. MINIMUM
(4) OUTLETS AND (4) DATA
PORTS PER STORE.
CENTER OF MENU
ASSEMBLY
3' - 8 1/4"3' - 8 1/4"
4"4"4"4"6"6"4"4"
2' - 9"2' - 9"
MIN. OFFSET (TYP.)
6"WALL MOUNTED
MENU BOARD
BRACKET
DIGITAL SCREEN
EQ
EQ
EQ.11' - 0 1/2" (3364.2MM 3 SCREENS)EQ.
12' - 0 1/2" (3670.3 MM MIN. BLOCKING (VIF))
MI
N
.
O
F
F
S
E
T
(
T
Y
P
.
)
6"
MAX. LENGTH DATA (5'-6")
MAX. LENGTH POWER (5'-6")
r
5
'
-
6
"
r
5
'
-
6
"
1
I506
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I506
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR DETAILS -
MENU BOARDS
Scale: 1 1/2" = 1'-0"1 DIGITAL MENUS - SECTION
Scale: 3/4" = 1'-0"2 DIGITAL MENU BOARDS - STANDARD MOUNT
Revision Schedule
Rev Date By Description
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I601
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
INTERIOR FINISHES &
CASEWORK SCHEDULES
WALL TREATMENT (AREA) SCHEDULE - "Q"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
WD0073 638 SF WOOD - WHITE OAK SB GC
WD0073
MAD200
157 SF WOOD - WHITE OAK - ROUNDED SLAT -
VERTICAL
SB GC
TILE
22823 537 SF TILE - MOSA - LIGHT BEIGE SMOOTH - 6X24IN
150X600MM
SB GC GROUT: MAPEI - 11 SAHARA BEIGE, OR
EQUAL
23801 663 SF TILE - I COCCI - GENERE - 6X24IN 150X600MM SB GC GROUT: MAPEI - 93 WARM GRAY
WALL COVERING
11469 1770 SF FRP - WHITE GC GC
PAINT SCHEDULE
DESIGN ID DESCRIPTION LRV FURN. BY INST. BY COMMENTS
X2851 SW2851 SAGE GREEN LIGHT, OR EQUIVALENT 16 GC GC
X7044 SW7044 AMAZING GRAY, OR EQUAVALENT 47 GC GC
X7045 SW7045 INTELLECTUAL GRAY, OR EQUIVALENT 36 GC GC SW USE PRIMER CP-1; NCS - S
3005-Y20R; AKZO NOBEL - 40YY 44/095
X7047 SW7047 PORPOISE, OR EQUIVALENT 13 GC GC
FLOOR TREATMENT SCHEDULE - "T"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
CONCRETE
X1112 1046 SF CONCRETE - SEALED & POLISHED GC GC
PLASTIC
19795 992 SF POLYVINYL FLOOR TILE - ECO-GRIP -
PEWTER
GC GC GC TO PROCURE FROM ALLIED
INDUSTRIES
WALL BASE SCHEDULE - "B"
DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS
METAL BASE
MT0028 121' - 5"METAL BASE, 6 IN, POWDER COAT, MATTE
BLACK
SB GC AT ENGINE FRONT - PROVIDED BY
CASEWORK VENDOR
VINYL BASE
19795 312' - 11"POLYVINYL BASE - ECO-GRIP - PEWTER GC GC LOCALLY SOURCED
CEILING TREATMENT SCHEDULE - "U"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
PLASTIC
11302 328 SF ACT VINYL - 2x4'GC GC MFR: ARMSTRONG
MODEL: 972 LUMAWASH
CASEWORK SCHEDULE - "C"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
CABINET
17573 1 CABINET - BACKBAR COUNTER SUPPORT PANEL
- 3IN 75MM
SB GC
17574 1 CABINET - BACKBAR SINK OR ICE - 15IN 380MM SB GC
17740 2 CABINET - BACKBAR - 30IN 760MM SB GC
17741 5 CABINET - BACKBAR 15IN 380MM SB GC
17743 1 CABINET - DT POS - 30IN 760MM SB GC
17744 1 CABINET - FRONTBAR POS BRIDGE - 22IN 560MM SB GC
17745 1 CABINET - BACKBAR DRAWER - 15IN 380MM SB GC
17747 8 CABINET - BACKBAR TRASH - 15IN 380MM SB GC
17896 1 CABINET - BACKBAR CUBBY - 15IN 380MM SB GC
19281 2 CABINET - ESPRESSO ICE BIN STAINLESS - 20IN
510MM
SB GC
21189 1 CABINET - FRONTBAR - 15IN 380MM SB GC
21190 1 CABINET - FRONTBAR TRASH - 15IN 380MM SB GC
21191 1 CABINET - FRONTBAR DRAWER - 15IN 380MM SB GC
21192 2 CABINET - FRONTBAR POS - 30IN 760MM SB GC
21193 1 CABINET - ESPRESSO CUBBY WITH OPEN BACK -
18IN 455MM
SB GC
23388 1 CABINET - BACKBAR - 18IN 460MM SB GC
23426 1 CABINET - WRM LOW - 30IN 760MM SB GC
X0001 1 CUSTOM CABINET - DT POS UPPER CUBBY - FULL
HEIGHT
SB GC CABINET FINISH: WILSONART -
FASHION GREY; MATCH CLOSELY
TO BACK BAR TILE
CABINETS
23709 1 CABINET - CBE UPPER CASEWORK IN-LINE - LF -
82IN
SB GC
CAFE
20383 1 FREESTANDING INLINE 2 UNIT SHORT - 72IN
1830MM - WHITE OAK WD0073
SB GC
23964 1 WASTE AND RECYCLE STATION THREE DROP -
GOLDEN BLONDE AND WHITE PL0027 CP0002
SB GC
COUNTERTOP
17807 8 COUNTERTOP - BACKBAR - 15IN 380MM SB GC
17809 1 COUNTERTOP - HAND SINK WITH LOW SPLASH
STAINLESS - 15IN 380MM
SB GC
17826 1 COUNTERTOP - DT POS - LF - 78IN 1980MM SB GC
17830 1 COUNTERTOP - POS - 82IN 2085MM SB GC
17843 1 COUNTERTOP - HANDOFF END CAP ROUNDED -
LF
SB GC
18721 1 COUNTERTOP - BREW WITH TRASH DROP - RF -
90IN 2285MM
SB GC
20061 1 COUNTERTOP - ESPRESSO METRO - RF - 139IN
3530MM
SB GC
20063 1 COUNTERTOP - FRONTBAR CAP - 139IN 3530MM SB GC
20273 1 COUNTERTOP - FRONTBAR MOP PLANAR - RF -
45IN 1145MM
SB GC
21941 1 COUNTERTOP - BACKBAR - 30IN 760MM SB GC
21960 1 COUNTERTOP - DT WARMING - RF - 108IN 2745MM SB GC
23409 1 COUNTERTOP - CBE IN-LINE LF - 138IN 3505MM SB GC
23433 1 COUNTERTOP - WRM RF - 79IN 1930MM SB GC
DIEWALL
17831 1 DIEWALL - POS - 82IN 2085MM SB GC
18859 1 DIEWALL - 45IN 1145MM SB GC
20064 1 DIEWALL - ESPRESSO - 139IN 3530MM SB GC
FIT KIT
17894 3 FIT KIT - CABINET FILLER PANEL SB GC
17895 1 FIT KIT - BACKBAR COUNTERTOP SB GC
23409 1 FIT KIT - BACKBAR COUNTERTOP SB GC
OTHER
11142 1 CORBEL SUPPORT - 24IN 610MM SB GC
11155 2 ESPRESSO MACHINE PUMP MOUNT - 10X10IN
255X255MM
SB GC
18145 4 COUNTERTOP SUPPORT LEG SB GC
20066 1 SHROUD - 139IN 3530MM SB GC
20633 3 COUNTERTOP SUPPORT LEG SLIM SB GC
PANEL
17832 1 PANEL - 82IN 2085MM SB GC
18860 1 PANEL - 45IN 1145MM SB GC
20065 1 PANEL - 139IN 3530MM SB GC
CASEWORK FINISH SCHEDULE
ENGINE ZONE MATERIAL DESCRIPTION FINISH CODE COMMENTS
COMPOSITE - BRUSHED WARM GREY
COUNTERTOPS - BACKBAR COMPOSITE - BRUSHED WARM GREY CP0056
COUNTERTOPS - ESPRESSO COMPOSITE - BRUSHED WARM GREY CP0056
COUNTERTOPS - FRONTBAR COMPOSITE - BRUSHED WARM GREY CP0056
COUNTERTOPS - SHROUD COMPOSITE - BRUSHED WARM GREY CP0056
METAL - FLAT BLACK POWDERCOAT
CABINETS - DOOR PULL METAL - FLAT BLACK POWDERCOAT MT0028
METAL - STAINLESS STEEL - BRUSHED
CABINETS - CABINET LEG METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
CABINETS - UNDERCOUNTER
ICE BIN
METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
COUNTERTOPS - HAND SINK METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
PLAM - MOTTLED BLACK
CABINETS - DT POS CUBBY PLAM - MOTTLED BLACK PL0019
CABINETS - UNDERCOUNTER PLAM - MOTTLED BLACK PL0019
CABINETS - UPPER PLAM - MOTTLED BLACK PL0019
WOOD - WHITE OAK - ROUNDED SLAT - VERTICAL
FINISH PANELS - FRONTBAR WOOD - WHITE OAK - ROUNDED SLAT -
VERTICAL
WD0073
MAD200
Revision Schedule
Rev Date By Description
WINDOW FILM SCHEDULE - "Z"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
19459 64 SF WINDOW FILM - FASARA - MILKY CRYSTAL GC GC GC TO PROVIDE SAMPLES TO
STARBUCKS FOR APPROVAL FROM
STARBUCKS DESIGN PRIOR TO
PURCHASING AND INSTALLATION
X19131 64 SF WINDOW FILM - SOLYX SXS-M6000 SILVER
MIRROR OPAQUE FILM ON EXTERIOR
GC GC GC TO PROVIDE SAMPLES TO
STARBUCKS FOR APPROVAL FROM
STARBUCKS DESIGN PRIOR TO
PURCHASING AND INSTALLATION
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I602
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
FF&E SCHEDULES
DATA DEVICE SCHEDULE - "A"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
AUDIO VISUAL
10005 1 MUSIC SYSTEM SB GC
10012 1 DT COMMUNICATION SYSTEM SB GC
10015 2 SPEAKER RECESSED - WHITE SB GC
10076 1 AMPLIFIER - 60W SB GC
22549 2 SPEAKER GRILLE RECESSED - BLACK SB GC
22725 1 DT DIGITAL PRODUCTION MONITOR SB GC PART OF RETAIL IT EQUIPMENT PACKAGE
22726 1 DT POS MONITOR ARM TRIPLE SURFACE MOUNTED SB GC PART OF RETAIL IT EQUIPMENT PACKAGE
DATA
10002 1 COMPUTER MANAGER WORKSTATION SB GC
10007 1 PRINTER MANAGER WORKSTATION SB GC
18744 1 EQUIPMENT RACK WITH LOCK - 24IN 610MM SB GC
20294 4 IOT MODULE SB GC
GRAPHICS - INTERIOR MENU
22970 4 MENU BOARD - DIGITAL DISPLAY - 44X25.25IN
1121X644MM - BLACK
SB GC
22972 1 MENU BOARD - DIGITAL MENU BOARD MOUNTING
BRACKET THREE SCREEN - BLACK
SB GC
23021 1 MENU BOARD - ORDER STATUS BOARD MOUNTING
BRACKET - BLACK
SB GC
POINT OF SALE
10008 2 POS - REGISTER WITH COMPACT CASH DRAWER SB GC
10014 3 POS PRINTER SB GC
10022 1 MONEY COUNTER SB GC
10029 6 POS BANK SB GC
10075 4 CUP LABELER SB GC
14677 1 POS - DT TENDERING REGISTER SB GC PART OF RETAIL IT EQUIPMENT PACKAGE
14678 1 POS - DT EXPEDITOR SB GC PART OF RETAIL IT EQUIPMENT PACKAGE
SECURITY
10024 1 SAFE LH - 20X18X26IN 510X455X660MM SB GC
10028 1 SAFE BASE SB GC
SPECIALTY EQUIPMENT SCHEDULE - "E"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
COOLING
10267 8 FRIDGE UNDERCOUNTER 1 DOOR - 27IN 685MM SB GC
11083 2 FRIDGE REACH IN 2 DOOR - 51X35IN 1295X890MM SB GC
12618 2 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF -
27IN 685MM
SB GC
13682 1 FREEZER REACH IN 2 DOOR - 54IN 1370MM SB GC
20010 1 FRIDGE NITRO 2 TAP JT NITCOM LH SB GC KIT INCLUDES UNDERCOUNTER
FRIDGE, FONT, TRAY, AND TUBING
EQUIPMENT
10808 1 GRINDER DITTING KR1203 SB GC
12508 2 BLENDER QUIET MODEL ON COUNTER SB GC
15186 1 DISHWASHER HOT LOW STEAM SB GC
17564 1 BLENDER PITCHER RINSER WITH SENSOR SB GC
19742 2 ESPRESSO MACHINE MASTRENA II SB GC
20032 2 OVEN EIKON E2S - BLACK SB GC
21679 1 NITROGEN GENERATOR ELEMENT COMPACT SB GC
22885 1 BREWER CLOVER VERTICA DOUBLE SB GC
23380 1 BREWER CLOVER VERTICA INSTALL KIT SB GC
23381 1 BREWER CLOVER VERTICA CORD SB GC
23393 3 EQUIPMENT - CBE MILK DISPENSE BRACKET
SLIDE
SB GC
23419 3 MILK DISPENSER SB GC
23442 1 OVEN COMBI SB GC
24117 1 DRIP TRAY MILK AND ICE DISPENSE SB GC
FOOD CASE
16239 1 FOOD CASE - ZEPHYR MINI - 54IN 1370MM SB GC
23444 1 FOOD CASE - WARMING WALL - 1000 SQUARE SB GC
ICE
18029 1 ICE - BIN B110 SB GC BPF-1 ADAPTER KIT (011076103)
REQUIRED WHEN PAIRING WITH
30" (760MM) ICE MACHINES
19278 2 ICE - BIN DROP IN 45LB 20KG HORIZONTAL SB GC
23182 1 ICE - MACHINE HMD1810RBT REMOTE COOLED SB GC
23338 1 ICE - BIN ADAPTOR FOLLETT B110H22H30
PEDESTAL TOP FOR B110
SB GC
23421 1 ICE - NUGGET ICE DISPENSER - SINGLE ICE
MACHINE
SB GC
23423 1 ICE - NUGGET ICE DIVERTER SB GC
OTHER
10091 1 CUP DISPENSER TALL HOT VERTICAL SB GC
10099 2 RESTROOM TOILET PAPER HOLDER SB GC
10172 2 RESTROOM SEAT COVER DISPENSER SB GC
10396 1 CUP DISPENSER SHORT HOT VERTICAL SB GC
10501 1 FIRE EXTINGUISHER SB GC
10769 2 RESTROOM GRAB BAR VERTICAL - 18IN 455MM SB GC
10791 2 CUP DISPENSER GRANDE VENTI COLD VERTICAL SB GC
10855 2 CUP DISPENSER GRANDE VENTI HOT VERTICAL SB GC
10858 1 CUP DISPENSER TALL COLD VERTICAL SB GC
10859 2 RESTROOM GRAB BAR - 48IN 1220MM SB GC
10862 2 RESTROOM GRAB BAR - 36IN 915MM SB GC
10947 1 SOAP DISPENSER WALL MOUNTED SB GC
10976 2 RESTROOM TRASH SANITARY NAPKIN
RECESSED
SB GC
10977 1 PAPER TOWEL DISPENSER FULL SIZE -
TRANSLUCENT GRAY
SB GC
11130 6 CORNER GUARD - 0.375IN 10MM - ANODIZED
ALUMINUM
GC GC
13330 1 MOBILE CUP DISPENSER CADDY SB GC
13584 1 CUP DISPENSER TRENTA COLD VERTICAL SB GC
20403 6 KEG - 3GAL SB GC
22627 1 NITRO 2 TAP HANDLE WITH BADGE AND MOUNT
KIT
SB GC JOE TAP, FOR USE AT BACKBAR
NITRO FONT
23420 2 REFRESHER DISPENSE SMALL SB GC
STORAGE
10222 1 WIRE SHELF GRID AT SINK SB GC
10416 10 WORKROOM SHELVING - 36IN 915MM SB GC
10462 10 WORKROOM SHELVING POSTS SB GC
10698 1 MOP RACK WITH 3 HOLDERS SB GC
13578 2 DISHWARE DRYING RACK - 21IN 535MM SB GC
13834 1 BASE - 24X18IN 610X455MM SB GC ITEM PROVIDED BY PENTAIR FOR
USE WITH WATER FILTRATON
SYSTEM
17255 1 PASTRY TRAY CART - 60IN 1525MM SB GC
17264 1 ROLLING PASTRY TRAY THAW RACK - 20X26IN
510X660MM
SB GC
21934 1 PASTRY TRAY RACK UNDERCOUNTER - 30IN
760MM
SB GC
22212 1 WORKROOM SHELVING CART KIT SB GC
23445 2 PASTRY COOLING RACK WALL MOUNTED SB GC
X0009 2 5 COMP LOCKER - 15X18IN 380X460MM SB GC
FURNITURE SCHEDULE - "F"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
BANQUETTE
23009 3 BANQUETTE - WALLFLOWER - VARIABLE LENGTH
- WHITE OAK WD0073
SB GC
23011 3 BANQUETTE - WALLFLOWER CUSHION SEAT AND
BACK - VARIABLE LENGTH - CARAMEL BROWN
NATURAL F0008
SB GC
TK0057 1 BANQUETTE - WALLFLOWER INSIDE END
VERTICAL STITCH STRAIGHT BACK - LEFT -
WHITE OAK WD0073 - CARAMEL BROWN
NATURAL F-0008
SB GC
TK0063 1 BANQUETTE - WALLFLOWER INSIDE END
VERTICAL STITCH STRAIGHT BACK - RIGHT -
WHITE OAK WD0073 - CARAMEL BROWN
NATURAL F-0008
SB GC
CHAIR
17852 4 CHAIR - CAFE PYRAMID - BLACK AND BROWN
ROPE MT0028 F0194
SB GC
20087 8 CHAIR - LOUNGE PYRAMID - BLACK AND BROWN
ROPE MT0028 F0194
SB GC
21456 5 CHAIR - CAFE ASHER UPHOLSTERED BACK -
WHITE OAK AND CARAMEL BROWN NATURAL
WD0073 F0008
SB GC
22718 5 CHAIR - LOUNGE MOON - BLACK AND CARAMEL
BROWN NATURAL MT0028 F0008
SB GC
22878 3 CHAIR - LOUNGE COMF - BLACK AND CARAMEL
BROWN NATURAL MT0028 F0008
SB GC
23063 10 CHAIR - CAFE PEGGY UPHOLSTERED - WHITE
OAK AND FERN GREEN WD0073 F0244
SB GC
TK0077 1 CHAIR - MANAGERS WORKSTATION SB GC STEELCASE SERIES ONE ARMLESS
DESK
TK0053 1 DESK - MANAGERS WORKSTATION SHELVES -
48IN 1220MM
SB GC
TK0076 1 DESK - MANAGERS WORKSTATION - 48X24X27IN
1220X610X685MM
SB GC
MIRROR
14350 2 MIRROR - RESTROOM ANGLED- 18X36IN
455X915MM
SB GC
OTHER
10756 2 COAT HOOK 1 PRONG SQUARE - 2IN 50MM - SST
TK0051 1 COAT HOOK STRIP - 30IN 760MM SB GC BLACK FINISH
OUTDOOR
X1010 2 WEST ELM PORTSIDE OUTDOOR DINING TABLE SB GC
X1011 2 WEST ELM PORTSIDE OUTDOOR DINING BENCH SB GC
STORAGE
TK0078 1 FILE MOBILE PEDESTAL WITH CUSHION AND
LOCK
SB GC
TK0079 1 MANAGERS DESK CART - 24X20IN 610X510MM SB GC
TABLE
20128 2 TABLE - OCCASIONAL COFFEE CAMERON - FLAT
BLACK MT0028
SB GC
21449 9 TABLE - BASE CAFE HEIGHT BOTTLE - FLAT
BLACK MT0028
SB GC
21453 1 TABLE - BASE ACCESSIBLE BOTTLE - FLAT BLACK
MT0028
SB GC
21800 1 TABLE - TOP ACCESSIBLE ROUND EDGE OBLONG
- 48X24IN 1220X610MM - WHITE OAK WD0073
SB GC
21842 4 TABLE - TOP ROUND EDGE ROUND - 24IN 610MM -
WHITE OAK WD0073
SB GC
21848 5 TABLE - TOP ROUND EDGE SQUARE - 24IN 610MM
- WHITE OAK WD0073
SB GC
TK0027 5 TABLE - OCCASIONAL SIDE COCO SB GC
X5050 1 WEST ELM - ORGANIC MODULAR TABLE - BLACK
ON ASH - SMALL
SB GC
WINDOW TREATMENT
22487 16 ROLLER SHADE - DARK GREY - 5PC OPEN SB GC
GRAPHICS AND ARTWORK SCHEDULE - "G"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
GRAPHICS - ARTWORK
23331 1 ASUKA WATANABECHROMATIC HACIENDA
ALSACIA - CORAL
SB GC ARTWORK PRINTED ON
SUBSTRATE. INSTALLED AS
WALLCOVERING.
23878 1 QUETZAL'S FLIGHT CARPENTER COLLECTIVE
MURAL
SB GC QUETZAL'S FLIGHT - PAINTABLE
EXTERIOR MURAL FOR DARK
WALLS
Revision Schedule
Rev Date By Description
TRUE / TUC-27-LP-HC
VITAMIX: SPRAYPARK
ELEMENT7: NG3000 SERIES
DONLIM: CM9700
PENTAIR: SHURFLO EV9910-00
DONLIM: CM9700
DONLIM: MILK MACHINE IP220238
CONVOTHERM OES 10.10 MINI eT
FLEXZONE 4 TIER FXZNA10S4S-SF61
ELKAY | LID-74763A\FSP211635
FOLLETT IMDV-2CM SERIES
TRUE / TG2R-2S-HC
TRAULSEN / UHT27-R0-0300-ZSB02
TRUE / T-49F-HC STAR
DITTING / KR1203
VITAMIX: 062911
HOBART:
THERMOPLAN: M2-CS
MERRYCHEF: E2SDBMV6DFL2SBUS
HORIZON ELITE | HMD1810RBT
FOLLETT | ID50
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2024 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2024.01.29
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
GRAPHITE DESIGN GROUP, LLC, ARCHITECTS
1807 7TH AVENUE, SUITE 700
SEATTLE, WA 98101
(206) 224-3335
I603
102442-001
05-03-2024
YE
L
M
&
K
I
L
L
I
O
N
93
7
Y
E
L
M
A
V
E
W
YE
L
M
,
W
A
9
8
5
9
7
84311
ALINA PINCHUK
GRAPHITE
GRAPHITE
PLUMBING & LIGHTING
SCHEDULES
NOTE:
THE SCHEDULES ON THIS SHEET ARE FOR OWNER'S ORDERING
PURPOSES ONLY. REFER TO ELECTRICAL AND PLUMBING DRAWINGS FOR
ADDITIONAL INFORMATION AND SPECIFICATIONS.
LIGHTING FIXTURE SCHEDULE - "L"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS
EXIT
19049 2 LED EXIT SIGN RECESSED - WHITE AND RED SB GC INTEGRATED LED
PENDANT
20831 3 PENDANT - TALA KNUCKLE - OAK SB GC 6 W LED, AS PACKAGED DROP LENGTH: 2'-10", 3'-2", AND 3'-6"
RECESSED CAN
21772 76 CAN - LED ADJUSTABLE RECESSED - 3IN
75MM - WHITE - 800LM FLOOD
SB GC INTEGRATED LED
SCONCE
20750 2 SCONCE - KUZCO PLUTO TRIPLE - VINTAGE
BRASS
SB GC AS PACKAGED: 1X LED G16
5W E26 BASE
X2851 2 SCONCE - SCHOOLHOUSE ELECTRIC
ALLEGHENY - BUTTERSCOTCH
SB GC AS PACKAGED: 1X LED G16
5W E26 BASE
STRIP
22216 17 STRIP - LED TAPE IN HOUSING - VARIABLE
LENGTH - WHITE - 350LM PER FT
SB GC INTEGRATED LED FIELD TRIMMABLE TO 0.9IN LENGTHS, 21' AT ART
WALL, 26' AT UNDERSIDE OF FRONT COUNTER
22400 1 STRIP - LED TAPE FLEXIBLE - VARIABLE
LENGTH - 250LM PER FT
SB GC INTEGRATED LED 6' 10" AT UNDERSIDE OF UPPER CASEWORK PER
RCP
TROFFER
15057 9 TROFFER - LED RECESSED - 24X48IN
600X1200MM - WHITE - 4000LM
SB GC INTEGRATED LED
PLUMBING FIXTURE SCHEDULE - "P"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
DRAIN
10294 7 DRAIN - FLOOR SINK SQUARE - 12IN 305MM SB GC
10594 3 DRAIN - SQUARE - 5IN 125MM GC GC
10726 7 DRAIN - GRATE HALF SQUARE - 12IN 305MM SB GC ZURN FD2375 HALF GRATE
FAUCET
10152 1 FAUCET - DOUBLE LABORATORY WITH BENT RISER
SPOUT
SB GC
10153 4 FAUCET - WATER TOWER - 12IN 305MM SB GC
10215 2 FAUCET - DOUBLE LABORATORY WITH SWING
SPOUT
SB GC
10447 1 FAUCET - PRE RINSE SPRAYER WALL MOUNTED SB GC
10597 1 FAUCET - SINGLE HANDLE SB GC
10804 1 FAUCET - PRE RINSE SWING SPOUT SB GC
10922 1 FAUCET - MOP SINK WALL MOUNTED SB GC
11003 2 FAUCET - METERED SB GC
13588 1 FAUCET - HAND SINK WALL MOUNTED SB GC
22642 3 FAUCET - INSTANTHOT SYSTEM 2 BUTTON WITH
BOILER AND BRACKET
SB GC KIT INCLUDES FONT,
UNDERCOUNTER BOILER AND
BOILER BRACKET FOR SIDE PANEL
MOUNTING. BRACKET CAN BE
FLOOR MOUNTED USING SET OF (4)
STAINLESS STEEL LEGS, ORDERED
SEPARATELY THROUGH VENDOR.
TK0042 2 FAUCET - RESTROOM BRADLEY LOOP WB1 WITH
SOAP AND DRYER
SB GC FINISH BRUSHED BRASS. INCLUDED
AS PART OF THE SINK
FILTER
12501 1 FILTER - RO SYSTEM 600GPD SB GC
12507 1 FILTER - RO SYSTEM STORAGE TANK RO40 SB GC
12896 1 FILTER - BRINE TANK SB GC
12899 2 FILTER - POLY GLASS VESSEL SB GC
13076 1 FILTER - PREFILTRATION SYSTEM SB GC
13082 1 FILTER - WATER SOFTENER TWIN SB GC
23355 1 FILTER - FILTRATION BOOSTER PUMP SB GC
OTHER
11109 1 WATER HEATER TANK ELECTRIC GC GC
TK0045 1 RESTROOM BRADLEY ENCLOSED ACCESS PANEL
DOUBLE SINK
SB GC BLACK FINISH PANEL
SINK
10549 1 SINK - RINSE DROP IN SST - 12X20IN 305X510MM SB GC
10995 1 SINK - MOP - 24X24IN 610X610MM SB GC
13264 1 SINK - 3 COMP WORK SST - 93IN 2350MM SB GC
14688 1 SINK - HAND WITH SIDE SPLASH WALL MOUNTED
SST
SB GC
17565 1 SINK - RINSE WITH DRAINBOARD - 15X27IN
380X685MM
SB GC
18743 1 SINK - WATER FILLING STATION - 36X24IN
915X610MM
SB GC
22768 2 SINK - COUNTERTOP RINSER WITH WATER TOWER -
26X9IN 660X235MM
SB GC
TK0040 1 SINK - RESTROOM BRADLEY DOUBLE LVQD2 WALL
MOUNTED
SB GC FINISH SANDSTONE. BRUSHED
BRASS FAUCET, BLACK ACCESS
PANEL
TOILET
22558 2 TOILET - TANKLESS AUTOMATIC SINGLE FLUSH GC GC
Revision Schedule
Rev Date By Description
GENERAL NOTES
SCOPE
THE INTENT OF THE DRAWINGS AND PROJECT MANUAL IS TO PROVIDE A
COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR,
MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE
ELECTRICAL WORK.
SITE EXAMINATION
THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL
AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED
AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS
THE PROPER INSTALLATION OF THE ELECTRICAL WORK.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE
PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS
APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE
OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE
CODES, THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL
CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM
STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS.
PERMITS AND FEES
THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL
PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE
ELECTRICAL WORK.
WARRANTY
THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT
ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP
FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE
BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS
AND WORKMANSHIP.
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITIES HAVING JURISDICTION
APPROX APPROXIMATE
BLDG BUILDING
CKT CIRCUIT
CLG CEILING
CM STARBUCKS CONSTRUCTION MANAGER
CONST CONSTRUCTION
CW COLD WATER
CXA COMMISSIONING AGENT
DEG DEGREES
DL LIGHTS WITHIN DAYLIGHT ZONE
DM STARBUCKS DESIGN MANAGER
DN DOWN
DTL DETAIL
DWG(S)DRAWING(S)
EA EACH
EC ELECTRICAL CONTRACTOR
ECP EQUIPMENT CONTROL PAC
EG EXHAUST GRILLE
ELEC ELECTRICAL
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
ETR EXISTING TO REMAIN
EXT EXTERIOR
F&I FURNISH & INSTALL
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER,
INSTALLED BY OWNER
FLR FLOOR
FT FOOT/FEET
GC GENERAL CONTRACTOR
GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER
GND GROUND
HR HOUR
HVAC HEATING, VENTILATION, AIR CONDITIONING
HW HOT WATER
LCP LIGHTING CONTROL PANEL
LL LANDLORD
LS LIGHT SENSOR PHOTOCELL
LV LOW VOLTAGE
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, AND PLUMBING
MFG MANUFACTURER
MIN MINIMUM
NL NIGHTLIGHT
NTS NOT TO SCALE
OCP OVERCURRENT PROTECTION
REF REFERENCE
REQ(’D)REQUIRE(D)
REV REVISION
SF SQUARE FEET
SHT SHEET
SPECS SPECIFICATION(S)
SST STAINLESS STEEL
TEL TELEPHONE
TEMP TEMPORARY
TYP TYPICAL
UC UNDER COUNTER
UNO UNLESS NOTED OTHERWISE
WH WATER HEATER
WP WEATHER PROOF
COMMUNICATION SYSTEM NOTES
CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS
FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE)
CONDUIT INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE
STREET FEED TO THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE
PROVIDER.
WIRELESS NETWORK NOTES
CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED
BY THE VENDOR FOR FIBER OR BROADBAND CONNECTIONS. T1 AND
ETHERNET EXTENSION CABLING IS PROVIDED BY THE STARBUCKS
(TELEPHONE/ NETWORK) CABLING VENDOR. COORDINATE WITH
STARBUCKS.
MUSIC SYSTEM NOTES
MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR
REFLECTED CEILING PLANS AND IN COORDINATION WITH ALL PLANS,
DETAILS AND MANUFACTURER'S INSTALLATION REQUIREMENTS.
INSTALL AND CONNECT OWNER FURNISHED WIRING SYSTEM BETWEEN
ALL SPEAKERS AND THE OWNER PROVIDED MUSIC SYSTEM. SET
WATTAGE TAP ON EACH SPEAKER'S ROTARY SWITCH PER TAP SETTINGS
NOTED ON PLANS.
POS \ DATA LINE NOTES
STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR
TO SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND
CONNECTORS FOR THE POINT OF SALE (POS) SYSTEMS. CONTRACTOR
TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING
VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR
INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL
INSTALLERS.
AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION
MANAGER SCHEDULES DELIVERY OF CASH REGISTER/MANAGER'S
WORKSTATION EQUIPMENT AND INSTALLATION BY A POS INSTALL
TECHNICIAN FOR ONE (1) MONTH PRIOR TO STORE OPEN.
CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR
TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED
DIRECTLY TO THE STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT
DELIVERY. DO NOT REFUSE DELIVERY.
DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND
CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER
LOCATIONS, MANAGER'S WORKSTATION, ALL OTHER NETWORKED
EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR, ETC...) AND
WIRELESS ACCESS POINT TO THE DATA RACK AREA. CONTRACTOR IS
TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL CABLE RUNS
PRIOR TO CABLE INSTALL DATE.
STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING
STARBUCKS POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS
VENDOR. THIS GROUP MAY BE CONTACTED AT:
NEWSTORES@STARBUCKS.COM .
SECURITY SYSTEM NOTES
STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY
AND INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE
INSTALLATION OF SECURITY SYSTEM FOR FOUR (4) TIMES;
1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE
INSTALLER PRIOR TO DRYWALL INSTALLATION.
2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS
PANEL, KEYPAD AND SENSORS.
3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR.
4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND
TRAIN PARTNERS AFTER POS INSTALL.
SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR
EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL
INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE
CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
TELEPHONE SYSTEM NOTES
IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE
STANDARD SINGLE LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL
CONTRACTOR SHALL CONTACT THE STARBUCKS CONSTRUCTION
MANAGER PRIOR TO BEGINNING CONSTRUCTION TO ORDER THE
ADDITIONAL TELEPHONE LINE(S). REPORT ANY TELEPHONE
INSTALLATION ISSUES IMMEDIATELY TO THE STARBUCKS
CONSTRUCTION MANAGER.
CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE
EXISTING, WORKING TELCO FACILITIES TO THE BUILDING OR THAT
LANDLORD HAS FURNISHED AND INSTALLED ONE (1) 2" (51MM) MIN.
(ENTRANCE) CONDUIT INCLUDING PULL STRING FROM TELCO STREET
FEED LINE TO THE BUILDING AS IDENTIFIED BY THE PHONE COMPANY.
NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF
FACILITIES OR CONDUIT AND PULL STRING ARE NOT INSTALLED.
GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN.
CONDUIT WITH PULL STRING FROM THE DATA RACK TO THE DEMARC
(TELCO TO CUSTOMER HAND OFF EQUIPMENT) WHEN THE DEMARC IS
MORE THAN 10' FROM THE DATA RACK. DISTANCES LESS THAN 10' WILL
NOT REQUIRE CONDUIT.
PROVIDE A 3-POSITION GROUND LUG, GROUNDED WITH #6 AWG
GROUND WIRE, IF REQUIRED BY TELEPHONE COMPANY.
ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE
TELEPHONE/NETWORK CABLING VENDOR.
GENERAL ELECTRICAL NOTES
1.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS
SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT
SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL
BUILDING DIMENSIONS. OVERALL CASEWORK COMPONENT
DIMENSIONING ON ELECTRICAL DETAILS ARE SHOWN FOR
REFERENCE AND COORDINATION ONLY. SEE PROJECT MANUAL.
2.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER
OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN
THE PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHEST PHASE
LOAD IN EACH PANEL BOARD.
3.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-
ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE
CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING
LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER
BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT
CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED.
4.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL
SYSTEM OUTAGES WITH THE GENERAL CONTRACTOR AND
LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED
OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND
5:00AM.
5.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
NECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETE
SECURITY, PHONE, POS AND DATA SYSTEMS. SEE MANAGER
WORKSTATION AND BAR POINT OF SALE (POS)
POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE
LOCATIONS AND MOUNTING HEIGHTS WITH SECURITY VENDOR
PRIOR TO ROUGH-IN. PROVIDE END-TO-END PULL STRINGS IN ALL
CONDUITS. LABEL EACH END OF THE PULL STRING WITH CONDUIT
SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT BAR",
ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND
EXPOSED CONDUIT ENDS.
6.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE
GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING
WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO
REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF
WORK.
7.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE
ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF
CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS,
COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER FOR
APPROVAL.
8.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH
ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH
SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS,
STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR
HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST
SWITCH LOCATION IF NEEDED. DO NOT MOUNT
RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT
WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE
TRANSITIONS, ETC.
CARBON MONOXIDE
(CO) DETECTOR NOTES
COORDINATE INSTALLATION OF CARBON MONOXIDE (CO) DETECTOR
DEVICE(S) AND LOW VOLTAGE WIRING WITH STARBUCKS SECURITY
VENDOR FOR NEW STORES, RELOCATIONS AND MAJOR RENOVATIONS, IF
IN VENDOR SCOPE. VENDOR TO PROVIDE AND INSTALL DEVICE(S) IN BOH
AND FOH (AS APPLICABLE PER STARBUCKS STANDARDS).
FIRE ALARM SYSTEM NOTES
IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE
ALARM MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS
SPECIFIED IN THE LEASE AGREEMENT, THE CONTRACTOR IS TO NOTIFY
GNOC IMMEDIATELY THAT FIRE ALARM LINES ARE NEEDED. STARBUCKS
PREFERRED FIRE ALARM SERVICE PROVIDER, STANLEY, IS TO BE
CONTACTED BY THE CONSTRUCTION MANAGER TO INSTALL FIRE ALARM
PANEL AND/OR MONITORING SERVICE AS REQUIRED.
ENERGY MANAGEMENT SYSTEM (EMS)
THE GENERAL CONTRACTOR SHALL INSTALLATION
VENSTAR SURVEYOR LCP AND EMS SYSTEM . PRIOR TO LAST WEEK
OF CONSTRUCTION, IF NEEDED, FURNISH AND INSTALL TEMPORARY
THERMOSTATS AND SENSORS, AND ROUTE ALL LOW VOLTAGE
WIRING THROUGH EC PROVIDED CONDUITS (COORDINATE WITH
ELECTRICAL).
FURNISH AND INSTALL RACEWAYS WITH PULL STRINGS AND
JUNCTION BOXES FOR THERMOSTAT(S) AND SENSOR(S).
SET RESTROOM OCCUPANCY SENSOR TO 15 MINUTE ‘ON’ DURATION
IN SINGLE OCCUPANT RESTROOM AND TO 20 MINUTE ‘ON’ DURATION
IN MULTI-OCCUPANT RESTROOM UNLESS JURISDICTION
REQUIREMENTS STATE OTHERWISE.
COORDINATE WITH DRAWINGS AND LCP VENDOR FOR DEVICE
LOCATIONS. VENDOR SHALL COMMISSION CONTROLS.
THE GENERAL CONTRACTOR IS TO COMPLETE FINAL CONNECTION
AFTER DATA RACK AND NETWORK INSTALLATION. THE GENERAL
CONTRACTOR IS TO CONTACT LCP VENDOR TO VERIFY SYSTEM
OPERATION AND TROUBLESHOOT IF REQUIRED.
LANDLORD REQUIREMENTS
PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD /
BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS. IF
LANDLORD / BUILDING OWNER DOES HAVE REQUIREMENTS, CONTRACTOR
SHALL BECOME COMPLETELY FAMILIAR WITH REQUIREMENTS AND
ADHERE TO THEM. WHERE LANDLORD / BUILDING OWNER REQUIREMENTS
ARE MORE STRINGENT THAN SHOWN IN THESE PLANS (IN THE OPINION OF
THE ENGINEER). LANDLORD / BUILDING OWNER REQUIREMENTS SHALL
GOVERN.
SYSTEM COMMISSIONING
CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING
CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED,
NEEDED AND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS
STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE
COMPRISED OF THREE DISTINCT EFFORTS:
1)SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING
INSTALLATION VERIFICATION AND CORRECT DISCLOSED
DEFICIENCIES;
2)PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM
STARTUP AND SUPPORT FUNCTIONAL PERFORMANCE TESTING
BY STARBUCKS CXA;
3)CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL
PERFORMANCE TESTING AND SUBMIT REPORTS. CONTRACTOR
SHALL PERFORM AND PROVIDE THE FOLLOWING:
A.SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE
NOT LIMITED TO DOMESTIC HOT WATER GENERATION, HVAC
SYSTEMS, ROOFTOP UNITS, EXHAUST FANS, HVAC CONTROLS,
LIGHTING CONTROLS, AIR CURTAINS, BUILT-IN REFRIGERATION
EQUIPMENT, AND RENEWABLE ENERGY SYSTEMS.
B.CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN
PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE
OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND
INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA.
CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL
WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM
IN THE SCHEDULE OF VALUES.
C.CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH
THE MANUFACTURER’S REQUIREMENTS AND ALL CONTRACT
DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED
TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR
INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE
TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION
VERIFICATION.
D.INSTALLATION VERIFICATION SHALL BE PERFORMED BY
STARBUCKS CXA. CONTRACTOR SHALL SUPPORT STARBUCKS
CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY.
PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR
STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS
INSTALLED CORRECTLY.
E.CONTRACTOR SHALL BE READILY AVAILABLE DURING
INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR
DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION
PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER
WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE.
F.ALL HVAC, EXHAUST FAN, AND AIR CURTAIN EQUIPMENT SHALL
BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR’S
TESTING, ADJUSTING AND BALANCE AGENT( SEE TESTING,
ADJUSTING AND BALANCING) AFTER THE SYSTEM IS VERIFIED TO
BE COMPLETE AND CORRECT BY STARBUCKS CXA, IN
ACCORDANCE WITH THE REQUIREMENTS OF THESE
DOCUMENTS.ALL HVAC CONTROL SYSTEMS SHALL BE TESTED
TO ENSURE THAT CONTROL DEVICES, COMPONENTS,
EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND
OPERATE IN ACCORDANCE WITH THESE PLANS AND PROJECT
MANUAL. SEQUENCES OF OPERATION SHALL BE TESTED
TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH THE
CONTRACT REQUIREMENTS. DELIVERABLES: PRELIMINARY,
WRITTEN TESTING AND AIR BALANCE REPORT CONFORMING TO
THE REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE
INFORMATION SPECIFIED, ETC. TO THE STARBUCKS CXA
IMMEDIATELY UPON COMPLETION OF THE WORK.
G.CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN
EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE
TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL
PERFORMANCE TESTING PRIOR TO STARTING TESTING.
CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS
CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION
OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER
EXECUTION OF HVAC CONTROL AND LIGHTING SEQUENCES;
INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, TEMPERATURE,
SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY
ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT AS
NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS
AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WILL
RECORD THE EQUIPMENT OPERATION AND RESPONSE TO
TESTING SEQUENCES AND PREPARE A LIST OF ANY
DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE
TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT
INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS,
ROOFTOP AND SPLIT TYPE, CONDENSING UNITS,EXHAUST FANS,
LIGHTING CONTROLS, ETC. DELIVERABLES: PROVIDE COMPLETED
COPIES OF ALL START UP REPORTS, FILLED OUT ON THE
MANUFACTURER'S FORMS, TO THE STARBUCKS CXA.
H.CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES
OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL
PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE
MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE
SYSTEM AND CONSTRUCTION SCHEDULE.
I.CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE-
TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS
CXA DURING INSTALLATION VERIFICATION AND FUNCTIONAL
PERFORMANCE TESTING. CONTRACTOR IS RESPONSIBLE FOR
CORRECTING ANY ISSUES OR DEFICIENCIES FOUND IN THE
SYSTEM DURING ANY AND ALL RE-TESTING. CORRECTIONS
SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO
THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES:
FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING
CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN
RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL
PERFORMANCE TEST RESULTS.
J.CONSTRUCTION AND POST CONSTRUCTION TESTING:
ADDITIONAL TESTING MAY BE REQUIRED AND OTHER
PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH
COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT,
DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS
DIRECTED BY STARBUCKS CXA.
A.
B.
C.
1)
2)
3)
4)
5)
THE EMERGENCY POWER SYSTEM SHALL ALSO BE CONNECTED TO
AN EMERGENCY ELECTRICAL SYSTEM WHICH IS TO PROVIDE
CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN 1
1/2 HOUR IN CASE OF PRIMARY POWER LOSS. CONTINUED
ILLUMINATION IS TO BE PROVIDED FROM STORAGE BATTERIES,
UNIT EQUIPMENT OR AN ON-SITE GENERATOR AND THE
INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH CHAPTER 27. (1013.6.3)
E.
EGRESS LIGHTING NOTES
CONN CONNECTION
NL
J
OS
JUNCTON BOX
HOMERUN FOR CIRCUIT
CONCEALED IN CEILING
OR WALL. 2#12 & 1#12
GND., 3/4" C., UNLESS
OTHERWISE NOTED.
3
ELECTRICAL SYMBOL LEGEND
PE
RECEPTACLE: DUPLEX
SWITCH
RECEPTACLE: DUPLEX -
GFCI BELOW COUNTERTHREE-WAY SWITCH
RECEPTACLE: QUAD
SPECIAL RECEPTACLE
GROUNDING ELECTRODE
CONNECTIONTELEPHONE
NIGHTLIGHTING 24HR/DAY
S THERMOSTAT SENSOR PHOTOELECTRIC CELL
DIMMER SWITCH
SPEAKER
RECEPTACLE: DATA
RECEPTACLE: FLOOR DUPLEX
RECEPTACLE: QUAD -
INDIVIDUAL BRANCH CIRCUIT
WIFI ACCESS POINT
D
CEILING MOUNTED OCCU-
PANCY SENSOR
DS DAYLIGHT SENSOR
CL CURRENT LIMITER
RECEPTACLE: CEILING DUPLEX
RECEPTACLE: GFCI WITH
WEATHERPROOF IN-USE COVER
WHERE ALSO NOTED 'WP'
GFCI
GFCI
WP
OS
RECEPTACLE: TAMPER
RESISTANT DUPLEX
T
FIRE ALARM CONTROL
PANEL SMOKE DETECTOR
PULL STATION HORN/STROBE
EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED
INTERNALLY ILLUMINATED EXIT SIGNS SHALL BE LISTED AND
LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED
IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
EXTERNALLY ILLUMINATED EXIT SIGNS SHALL COMPLY WITH THE
GRAPHICS AND POWER SOURCE REQUIREMENTS IN SECTIONS
1013.6.1 AND 1013.6.3 RESPECTIVELY. WHEN THE FACE OF AN EXIT
SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE
AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 LUX).
(1013.3)
D.
ANYTIME A BUILDING OR A PORTION OF A BUILDING IS OCCUPIED,
THE MEANS OF EGRESS SERVING THE OCCUPIED PORTION SHALL
BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT
CANDLE (11 LUX) AT THE WALKING SURFACE LEVEL. (1008.2.1)
THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL
BE PROVIDED BY THE PREMISE'S ELECTRICAL SUPPLY, IN THE
EVENT OF POWER SUPPLY FAILURE, ILLUMINATION SHALL BE
AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM FOR
THE FOLLOWING AREAS. (1008.3):
AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND
SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS.
CORRIDORS, INTERIOR EXIT STAIRWAYS & RAMPS AND EXIT
PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR
MORE EXITS.
EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL
OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED
FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN
SECTION 1028.1 IN BUILDINGS REQUIRED TO HAVE TWO OR
MORE EXITS.
EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.2.2 EXIT
DISCHARGE DOORWAYS IN BUILDING REQUIRED TO HAVE TWO
OR MORE EXITS.
EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO
PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1
FOOT CANDLE (11 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOT
CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT
FLOOR LEVEL. A MAXIMUM TO MINIMUM ILLUMINATION UNIFORMITY
RATION OF 40:1 SHALL NOT BE EXCEEDED. (1008.3.5)
RECEPTACLE WITH USB CHARGING PORT
PROVIDE UL FEDERAL SPECIFICATION CERTIFIED TAMPER-RESISTANT
DUPLEX RECEPTACLE WITH USB CHARGING CAPABILITIES. FEATURES
SHALL INCLUDE OVERALL 3.1A USB CHARGING CAPABILITY, AUTO GROUND
CLIPS, ZINC-PLATED GROUND TERMINAL SCREW AND TRIPLE-WIPE BRASS
CONTACTS.
PASS & SEYMOUR #TR5362USB* OR EQUAL
*- FINISH COLOR SHALL BE AS SPECIFIED ON ARCHITECTURAL DRAWINGS
OR AS DIRECTED BY OWNER'S REPRESENTATIVE.
MOTION (VACANCY)
SENSOR SWITCHVS
MOTION (OCCUPANCY)
SENSOR SWITCH
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-001
ELECTRICAL NOTES
ELECTRICAL SPECIFICATIONS
1.FURNISH AND INSTALL A COMPLETELY WIRED AND OPERATIONAL ELECTRICAL SYSTEM
AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN, INCLUDING BUT NOT LIMITED
TO, THESE MAJOR ITEMS.
A.LIGHTING FIXTURES AS INDICATED AND SPECIFIED ON THE PLANS.
B.ELECTRICAL PANELS, SERVICE, CONDUIT, WIRING, ETC., FOR ALL OUTLETS AND
EQUIPMENT.
C.TELEPHONE OUTLETS AND CONDUIT AS INDICATED.
PART I - GENERAL
A. CONDITIONS
B. RELATED WORK BY OTHERS
1.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, TRENCH, AND BACKFILL FOR ELECTRICAL
SERVICE ENTRANCE FROM THE MAIN SERVICE TO UTILITY POINT OF ELECTRICAL SERVICE. ELECTRICAL
CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE ELECTRICAL SERVICE ENTRANCE WITH
SERVING UTILITY COMPANY.
2.THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, TRENCH, AND BACKFILL FOR PRIMARY PHONE
AND CATV SERVICE FROM THE TELEPHONE TERMINAL BOARD OR CABINET TO THE PHONE COMPANY
AND CATV COMPANY POINT OF SERVICE.
C. CODES, REGULATIONS, AND STANDARDS
1.THE INSTALLATION SHALL COMPLY WITH APPLICABLE LOCAL AND STATE CODES AND
ORDINANCES,WITH THE REGULATIONS OF THE CURRENTLY ACCEPTED EDITION OF THE NATIONAL
ELECTRIC CODE AND WITH THE REQUIREMENTS OF THE POWER,TELEPHONE, AND CATV COMPANIES
FURNISHING SERVICES TO THIS INSTALLATION.
2.ELECTRICAL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH THE
NECA INSTALLATION STANDARDS TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER.
3.ALL WORK MATERIALS,A ND EQUIPMENT SHALL CONFORM TO THE CURRENTLY ACCEPTED EDITION OF
ALL APPLICABLE NATIONAL, STATE, AND CITY CODES AND ORDINANCES. THE FOLLOWING INDUSTRY
STANDARDS, SPECIFICATIONS, AND CODES ARE MINIMUM REQUIREMENTS:
A.THE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION STANDARDS.
B.THE NATIONAL ELECTRICAL CODE, INCLUDING LOCAL AMENDMENTS.
C.UNDERWRITER LABORATORIES INCORPORATED STANDARDS.
D.AMERICAN NATIONAL STANDARDS INSTITUTE.
D. INSPECTION OF SITE
1.PRIOR TO SUBMITTING A BID FOR ELECTRICAL WORK, THE CONTRACTOR SHALL VISIT THE SITE OF THE
PROPOSED CONSTRUCTION AND SHALL THOROUGHLY ACQUAINT HIMSELF WITH EXISTING UTILITIES,
AND WORKING CONDITIONS TO BE ENCOUNTERED, ETC. ALLOWANCE WILL NOT BE MADE FOR
NONCOMPLIANCE WITH THIS CONDITION AFTER BIDDING.
2.ELECTRICAL INSTALLATION SHALL MEET THE EXISTING CONDITIONS.
3.CONTRACTOR SHALL VERIFY, WITH OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING BID, ALLOWABLE
WORKING HOURS, EMPLOYEE PARKING AREAS, MATERIAL DELIVERY, STORAGE REQUIREMENTS,
DEMOLITION AND REMOVAL OF CONSTRUCTION DEBRIS, AS WELL AS DAILY CLEAN UP REQUIREMENTS.
INCLUDE ALL COSTS IN BID FOR DUST BARRIERS, DUMPSTERS, ETC. AS REQUIRED FOR THE DURATION
OF THE PROJECT. PERFORM ALL WORK AS DIRECTED BY OWNER'S REPRESENTATIVE AND ARCHITECT.
F. CLEANUP
1.KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS, OR RUBBISH CAUSED BY
EMPLOYEES OR WORK UNDER THIS DIVISION OF THE SPECIFICATIONS. AT THE COMPLETION OF THE
WORK REMOVE ALL SURPLUS MATERIALS, TOOLS, ETC., AND LEAVE THE PREMISES BROOM-CLEAN.
G. EXCAVATION
1.PERFORM ALL EXCAVATION AND BACK BACKFILING REQUIRED FOR WORK PERFORMED UNDER THIS
DIVISION OF THE SPECIFICATIONS. USE EXCAVATED MATERIALS FOR BACKFILL UNLESS OFF SITE
MATERIALS ARE DEEMED NECESSARY.
H. DRAWINGS
1.THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE ELECTRICAL
WORK DATA PRESENTED ON THESE DRAWINGS ARE AS ACCURATE AS PLANNING CAN
DETERMINE, BUT FIELD VERIFICATION OF ALL DIMENSIONS, LOCATIONS, LEVELS, ETC., TO SUIT
FIELD CONDITIONS IS REQUIRED. REVIEW ALL ARCHITECTURAL, STRUCTURAL, AND
MECHANICAL DRAWINGS AND ADJUST ALL WORK TO MEET THE REQUIREMENTS OF
CONDITIONS SHOWN. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL
OTHER DRAWINGS. DISCREPANCIES BETWEEN DIFFERENT PLANS, OR BETWEEN DRAWINGS
AND SPECIFICATIONS, OR REGULATIONS AND CODES GOVERNING THE INSTALLATION SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE THE DATE OF BID
OPENING. IF DISCREPANCIES ARE NOT REPORTED, THE CONTRACTOR SHALL BID THE GREATER
QUANTITY OR BETTER QUALITY, AND APPROPRIATE ADJUSTMENTS WILL BE MADE AFTER
CONTRACT AWARD. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD MEASURE AND CONFIRM
MOUNTING HEIGHTS AND LOCATION OF ELECTRICAL EQUIPMENT WITH RESPECT TO
COUNTERS, RADIATION, ETC. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS, USE
ACTUAL BUILDING DIMENSIONS.
2.IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF
QUALITY. THE ENGINEER RESERVES THE RIGHT TO ALLOW OTHER METHODS AND MATERIALS
NOT REFLECTED HEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE TO REQUEST THE
ENGINEER WAIVE THE STANDARDS TO ALLOW ALTERNATE MEANS AND METHODS PRIOR TO
BEGINNING THE PROJECT. CONTRACT DOCUMENT REVISIONS TO ACCOMMODATE INSTALLED
CONDITIONS, WITHOUT PRIOR APPROVAL, WILL RESULT IN ADDITIONAL DESIGN CHARGES TO
THE CONTRACTOR.
3.VERIFY EXACT LOCATION OF ALL DEVICES, JUNCTION BOXES, LIGHTING FIXTURES, ETC. WITH
ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS PRIOR TO INSTALLATION. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND OTHER
EQUIPMENT REQUIRING ELECTRICAL CONNECTION PRIOR TO ROUGH-IN. EVERY OUTLET
HEIGHT SHALL BE VERIFIED ON EACH WALL WITH THE INTERIOR PLANING AND DESIGN
DRAWINGS. COORDINATE WITH CABINET SHOP DRAWINGS TO ENSURE PROPER HEIGHT AND
LOCATION WITH RESPECT TO MILLWORK, EQUIPMENT, ETC.
E. STORAGE AND HANDLING OF MATERIAL
1.DELIVER MATERIALS AND EQUIPMENT TO THE PROJECT IN THE MANUFACTURER'S ORIGINAL,
UNOPENED, LABELED CONTAINERS. PROTECT AGAINST MOISTURE, TAMPERING, OR DAMAGE FROM
IMPROPER HANDLING OR STORAGE. CONTRACTOR SHALL PROTECT AND BE RESPONSIBLE FOR ANY
DAMAGE TO WORK OR MATERIALS UNTIL FINAL ACCEPTANCE BY THE OWNER, AND SHALL MAKE GOOD
WITHOUT COST TO THE OWNER, AND DAMAGE OR LOSS THAT MAY OCCUR DURING THIS PERIOD.
2.ARRANGE FOR TIMELY DELIVERY OF MATERIALS AND EQUIPMENT TO THE JOB SITE IN ORDER TO
MINIMIZE THE LENGTH OF TIME BETWEEN DELIVERY AND INSTALLATION.
3.COVER AND PROTECT ANY MATERIAL WHICH MAY BE AFFECTED BY THE WEATHER WHILE IN TRANSIT
OR STORED AT THE PROJECT SITE. ANY MATERIAL FOUND DEFECTIVE OR NOT INSTALLED IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS MAY BE REJECTED BY THE ENGINEER.
J. COOPERATION WITH OTHER CONTRACTORS
1.COOPERATE WITH THE OTHER TRADES SO THAT THE INSTALLATION OF THE ELECTRICAL OUTLETS AND
EQUIPMENT WILL BE PROPERLY COORDINATED. CONDUIT, LIGHTING FIXTURES, AND OTHER
EQUIPMENT LOCATIONS SHALL BE CHECKED WITH OTHER TRADES TO AVOID CONFLICT WITH THE
PIPING, DUCTWORK, STEEL, BEAMS, OR OTHER OBSTRUCTIONS. CAREFULLY CHECK THE LOCATIONS OF
THE OUTLET BOXES AND DETERMINE THAT THEY HAVE NOT BEEN DISTURBED DURING THE
INSTALLATION OF MATERIALS OF OTHER TRADES.
2.COORDINATE THE LOCATION OF THE TRENCHES AND CONDUITS FOR ELECTRICAL AND TELEPHONE
UTILITY SERVICES WITH THE GENERAL CONTRACTOR.
3.COORDINATE HVAC EQUIPMENT CONNECTION REQUIREMENTS WITH HVAC CONTRACTOR.
PART II - PRODUCTS AND EXECUTION
A.MATERIALS
1.ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE NEW AND OF QUALITY AS SPECIFIED ON THE PLANS
OR SPECIFICATIONS AND MUST CARRY THE UNDERWRITER'S LABORATORIES OR OTHER RECOGNIZED
TESTING FACILITY AS ALLOWED BY AUTHORITY HAVING JURISDICTION. APPROVAL COVERING THE
PURPOSE FOR WHICH THEY ARE USED, IN ADDITION TO MEETING ALL REQUIREMENTS OF THE
CURRENT APPLICABLE CODES AND REGULATIONS.
B. CONDUIT
1.RACEWAY SYSTEMS ARE SHOWN DIAGRAMMATICALLY. ACTUAL LOCATION AND ROUTING OF ALL,
SHALL BE DETERMINED BY CONTRACTOR TO SUIT FIELD CONDITIONS. ELECTRICAL INSTALLATION SHALL
MEET THE EXISTING CONDITIONS.
2.PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT. HOME RUN CONDUCTORS MAY BE COMBINED
INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) CURRENT
CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE (3) ARE INDICATED ON
THESE DRAWINGS, THEY HAVE BEEN DERATED AS REQUIRED BY NEC ARTICLE 310 REQUIREMENTS.
3.CONTRACTOR SHALL PROVIDE ALL RACEWAY SYSTEMS INDICATED ON THE DRAWING PER NEC
REQUIREMENTS AND GENERAL NOTES. ANY DEVIATION FROM THE WIRING METHODS INDICATED
SHALL BE ALLOWED ONLY BY SPECIFIC WRITTEN APPROVAL FROM EITHER THE ARCHITECT, ENGINEER
OR OWNER. CONTRACTOR'S BID SHALL INCLUDE ALL COSTS FOR RACEWAY SYSTEMS AS SPECIFIED
UNLESS SPECIFIC WRITTEN APPROVAL FOR AN ALTERNATIVE WIRING METHOD IS OBTAINED FROM
EITHER THE ARCHITECT, ENGINEER OR OWNER AND IS SUBMITTED AS PART OF CONTRACTOR'S
FORMAL BID PROPOSAL.
4.WHERE ALLOWED, MC CABLE MAY BE INSTALLED PER NEC ARTICLE 330. WHERE MULTIPLE CABLES ARE
ROUTED ADJACENT TO EACH OTHER (BUNDLED), A MINIMUM SEPARATION OF ONE (1) CABLE
DIAMETER (LARGEST) SHALL BE REQUIRED.
A.PLASTIC CABLE TIES SHALL NOT BE USED AS A MEANS OF SUPPORT FOR MC CABLE. USE ONLY
APPROVED CABLE SUPPORTS PER CABLE MANUFACTURER'S INSTALLATION REQUIREMENTS.
5.ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC CONDUIT EXCEPT AS PERMITTED BELOW. RGS,
WITH A 20 MIL PVC COATING WILL BE USED WHEN IN CONTACT WITH EARTH. IMC MAY BE USED IN
INDOOR LOCATIONS NOT IN CONTACT WITH THE EARTH. EMT MAY BE USED IN INDOOR LOCATIONS
NOT IN CONTACT WITH EARTH, NOT IN CONCRETE SLABS OR WALLS AND NOT SUBJECT TO DAMAGE.
PVC MAY BE USED IN OR BELOW CONCRETE AND DIRECT BURIED IN EARTH. LIQUID-TIGHT FLEXIBLE
STEEL CONDUIT SHALL BE FOR OUTDOOR FINAL CONNECTIONS TO EQUIPMENT NOT TO EXCEED 36".
6.WHERE CONDUIT ENTERS OUTLET BOXES, FIXTURES OR CABINETS, FIRMLY FASTEN WITH STEEL SET
SCREW, COMPRESSION CONNECTORS, OR DOUBLE LOCKNUTS FOR GRC. ALL CONNECTIONS SHALL
HAVE BUSHINGS OR INSULATED THROAT CONNECTORS. FIRMLY FASTEN CONDUIT TO THE BUILDING
CONSTRUCTION. RUN EXPOSED CONDUIT PARALLEL TO THE BUILDING LINES, SUPPORTED BY
APPROPRIATE HANGERS (UNISTRUT, T & B OR APPLETON, OR EQUAL).
7.COVER METALLIC CONDUIT IN CONTACT WITH EARTH WITH POLYETHYLENE TAPED SPIRAL WRAPPED,
1/2 LAPPED TO PROVIDE 20 MIL. THICKNESS. TAPE SHALL BE SCOTCH NO. 50 TAPE. CONDUIT AND
DUCTS NOT UNDER BUILDINGS AND FEEDER DUCTS SHALL BE INSTALLED PER N.E.C. 300-5. MAKE
JOINTS WITH COMPOUND TO BE WATERTIGHT.
8.FITTINGS AND CONDUIT BODIES SHALL BE STEEL. NO DIECAST FITTINGS.
9.CONDUIT SIZES SHALL BE AS REQUIRED BY CODE AND AS INDICATED OR SPECIFIED.
10.ALL EMPTY CONDUIT SYSTEMS SHALL HAVE A NYLON PULL STRING TO FACILITATE INSTALLATION OF
FUTURE WIRE. WHERE MORE THAN ONE CONDUIT TERMINATES IN A JUNCTION BOX, THE
CONTRACTOR SHALL IDENTIFY EACH CONDUIT AND JUNCTION BOX IN A MANNER ALLOWING
IDENTIFICATION AFTER ALL WALL FINISHES HAVE BEEN APPLIED.
11.SCHEDULE 40 PVC CONDUIT SHALL BE PERMITTED UNDERGROUND WITH PROPER FITTINGS, ALL UL
APPROVED AND CEMENTED JOINTS. PENETRATIONS THROUGH FLOOR SLABS AND BENDS GREATER
THAN 22° SHALL BE WRAPPED RIGID GALVANIZED STEEL ELBOWS. ALL UNDERGROUND SERVICE
CONDUITS SHALL BE SEALED PER NEC ARTICLE 230-8.
12.CONDUITS AND OUTLETS SHALL BE CONCEALED WITH THE BUILDING STRUCTURE, EXCEPT THAT
CERTAIN MOTOR AND LIGHTING FEEDER CONDUITS MAY BE RUN EXPOSED IN CERTAIN AREAS AS
INDICATED ON THE DRAWINGS. CONDUIT SHOWN TO BE INSTALLED IN CABINETS, COUNTERS, AND
CASEWORK SHALL BE RUN AS DIRECTED BY THE ARCHITECT.
13.MINIMUM RACEWAY SIZE SHALL BE 1/2". MINIMUM HOMERUN SIZE SHALL BE 3/4". MINIMUM
CONDUCTOR SIZE SHALL BE #12 AWG U.N.O. TYPICAL. ALL POWER RELATED CONDUITS SHALL HAVE A
CODE SIZE GROUND WIRE INSTALLED IN EACH RUN.
14.CONDUIT PENETRATION THROUGH ROOF SHALL HAVE ROOF FLASHING WITH CAULK TYPE COUNTER
FLASHING SLEEVE. INSTALLATION SHALL BE WATERTIGHT.
15.CONDUITS SHALL BE ROUTED SURFACE ON THE STRUCTURE, PARALLEL AND PERPENDICULAR TO THE
STRUCTURE.
16.PROVIDE APPROVED EXPANSION FITTINGS WHERE RACEWAYS CROSS BUILDING EXPANSION JOINTS.
PROVIDE BONDING JUMPER(S) SIZED PER CODE WHERE REQUIRED. PROVIDE ALL FITTINGS REQUIRED
FOR A COMPLETE INSTALLATION. REFER TO ARCHITECTURAL DRAWINGS FOR EXPANSION JOINT
LOCATION(S).
17.ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND
INSTALLATION DIAGRAMS THAT CONFORM TO UL LISTING FOR "THROUGH-PENETRATION FIRE STOP
SYSTEMS".
18.PROVIDE 10 AWG CONDUCTORS FOR 20 AMPERE, 120V BRANCH CIRCUITS LONGER THAN 75' AND 8
AWG CONDUCTORS FOR 20 AMPERE, 120V BRANCH CIRCUITS LONGER THAN 120'. PROVIDE 10 AWG
CONDUCTORS FOR 20 AMPERE, 277V BRANCH CIRCUITS LONGER THAN 200'.
1.CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT SIZE AND INSTALLATION OF ALL
OUTLET, PULL AND JUNCTION BOXES IN ACCORDANCE WITH NEC 314-16.
2.EACH SWITCH, LIGHT. RECEPTACLE OR OTHER OUTLET SHALL BE PROVIDED WITH A
CODE GAUGE, GALVANIZED STEEL OUTLET BOX. JUNCTION AND PULL BOXES SHALL BE
CODE GAUGE, GALVANIZED STEEL. OUTLET BOXES SHALL BE OF THE ONE PIECE,
KNOCKOUT TYPE, IN GENERAL 4" SQUARE WITH PLASTER RING. PLASTER RINGS SHALL
BE SET TO PROVIDE NOT MORE THAN 1/8" FROM WALL SURFACE TO RING. IN NO CASE
SHALL PLASTER RING PROJECT BEYOND SURFACE OF WALL. SINGLE GANG RINGS
SIMILAR TO STEEL CITY 52050 SHALL BE USED FOR 4" BOXES IN UNFINISHED BRICK
NUMBER 180 BOXES MAY BE USED FOR UNFINISHED MASONRY FLUSH WALL OUTLETS.
CENTER ALL OUTLET BOXES IN BLOCK COURSE.
3.BOXES INSTALLED IN POURED CONCRETE FLOORS SHALL BE FLUSH TYPE CAST IRON
OR STEEL WITH WATERTIGHT GASKETED COVERS. WHERE BOXES ARE INSTALLED IN
FLOORS WITH TILE OR CARPET FLOOR COVERING, COVERS SHALL BE OF THE
RECESSED TYPE TO ACCOMMODATE THE FLOOR COVERING.
4.BOXES INSTALLED FOR THE ALARM, COMPUTER, AND SECURITY SYSTEM SHALL BE
PROVIDED WITH APPROPRIATE COVER PLATES.
5.BOXES FOR TELEPHONE, COMPUTER, T.V., FIRE ALARM, SECURITY, AND SIMILAR
SYSTEMS SHALL BE MINIMUM 4" SQUARE AND 2-1/8" DEEP.
C. OUTLET, PULL, AND JUNCTION BOXES
1.CIRCUIT BREAKER TYPE AS INDICATED ON DRAWINGS. UNLESS INDICATED
OTHERWISE, ALL PANELS SHALL HAVE PANEL BOARD TYPE CONSTRUCTION WITH
BOLT-ON CIRCUIT BREAKERS FOR 3Ø PANELS. SNAP IN BREAKERS ARE NOT ALLOWED
UNLESS APPROVED BY ENGINEER. MANUFACTURERS SHALL BE SQUARE D (OR AS
APPROVED BY ENGINEER AND STARBUCKS MANAGER) WITH VOLTAGE, SIZES, AND
RATINGS AS INDICATED ON DRAWINGS.
2.THE CIRCUIT BREAKERS SHALL BE OPERABLE IN ANY POSITION AND BE REMOVABLE
FROM THE FRONT OF THE PANEL BOARD WITHOUT DISTURBING THE ADJACENT UNITS.
BRANCH BREAKERS SHALL BE OF SUCH DESIGN THAT COMBINATION OF SINGLE-POLE,
DOUBLE-POLE, AND THREE-POLE BREAKERS CAN BE ASSEMBLED ON THE SAME PANEL.
EACH BRANCH CIRCUIT SHALL BE CLEARLY NUMBERED. BRANCH AND MAIN
TERMINALS SHALL BE OF THE SOLDERLESS TYPE. HANDLE TIES TO FORM MULTI-POLE
BREAKERS NOT ACCEPTABLE.
3.PROVIDE AND UPDATE A TYPEWRITTEN CIRCUIT INDEX BEHIND CLEAR PLASTIC COVER
ON INSIDE OF DOOR. INFORMATION SHALL INCLUDE ROOM AND TYPE LOAD SERVED.
ALL CIRCUIT BREAKERS SHALL BE IDENTIFIED, INCLUDING SPARES. INDEX CARD
FRAME SHALL BE METAL, SECURED TO DOOR. INDEX SHALL REFLECT AS-BUILT FINAL
CONDITIONS.
4.ALL EQUIPMENT ELECTRICAL TERMINATIONS TO UNDERGO A TORQUE TEST.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MANUFACTURER'S RECOMMENDED
TORQUE DOCUMENTATION AND TOOLS TO PERFORM TORQUE TEST.
E. PANEL BOARDS
1.CONDUCTOR SIZES SHOWN ON THE DRAWINGS ARE BASED ON COPPER WIRE. UNLESS
OTHERWISE SPECIFIED, ALL WIRE SHALL BE TYPE XHHW FOR FEEDERS OR BRANCH
CIRCUITS LARGER THAN 4 AWG, TYPE THHN/THWN INSULATION FOR FEEDERS AND
BRANCH CIRCUITS 4 AWG AND SMALLER. ALL BRANCH CIRCUIT WIRING SHALL BE
COPPER. THE WIRES SHALL BE MARKED WITH COLOR TO SIMPLIFY CIRCUIT
IDENTIFICATION. UNLESS OTHERWISE REQUIRED BY LOCAL ORDINANCES GROUND
WIRES SHALL BE GREEN, NEUTRAL WIRES SHALL BE 120V- WHITE, 277V- GRAY, AND
LIVE WIRES 208Y/120V AND 120/240 SHALL BE BLACK (PHASE A), RED (PHASE B), AND
BLUE (PHASE C). FOR 480Y/277V CIRCUITS, THE COLOR CODE SHALL BE BROWN
(PHASE A), ORANGE (PHASE B), AND YELLOW (PHASE C). THE WIRE SHALL BE 12 AWG
UNLESS OTHERWISE INDICATED. CIRCUIT SHALL BE LABELED IN EACH J-BOX.
2.USE OF ALUMINUM WIRE IS NOT PERMITTED.
3.NO WIRE SHALL BE INSTALLED IN THE CONDUIT SYSTEM UNTIL THE CONDUIT SYSTEM
IS COMPLETE. USE MINERALAC NO. 100 OR EQUIVALENT AS A LUBRICANT TO
FACILITATE THE INSTALLATION OF THE CONDUCTORS IN THE CONDUIT SYSTEM.
4.SPLICES IN EXTERIOR PULL BOXES AND MANHOLES SHALL BE WEATHERPROOF USING
"SCOTCHCAST" SPLICE KIT OR APPROVED EQUAL. SEAL ENDS OF CONDUITS AND
DUCTS WITH "DUCTSEAL" OR APPROVED EQUAL.
5.PROVIDE SOLID CONDUCTOR FOR 12 AWG AND SMALLER.
F. WIRE
1.WALL SWITCHES SHALL BE SPECIFICATION GRADE AC SILENT TYPE SWITCHES, 20A,
120/277 VOLT.
2.RECEPTACLES SHALL BE SPECIFICATION GRADE, DUPLEX TYPE, NEMA 5-20R, 20
AMPERE, 120 VOLT GROUNDED TYPE. SPECIAL APPLICATION RECEPTACLES SHALL BE
INDICATED ON PLANS. MOUNT WITH THE GROUND DOWN.
3.DEVICE PLATES SHALL BE EQUAL TO SIERRA SMOOTH-LINE PLASTIC WALL PLATES.
COLOR SHALL BE WHITE, UNLESS OTHERWISE NOTED.
4.RECEPTACLES IN OUTDOOR AND WET LOCATIONS SHALL BE INSTALLED WITH A HINGED
OUTLET COVER/ENCLOSURE CLEARLY MARKED AND U.L. LISTED SUITABLE FOR WET
LOCATIONS WHILE IN USE, EQUAL TO TAYMAC SPECIFICATION GRADE.
G. WIRING DEVICES
1.REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT LOCATION
OF ALL CEILING MOUNTED LIGHTING FIXTURES. ARCHITECTURAL DRAWINGS SHALL
GOVERN IN CASE OF CONFLICT WITH THESE DRAWINGS.
2.PROVIDE ALL LIGHTING FIXTURES, WIRED AND CONNECTED. THE DRAWINGS INDICATE
THE FIXTURES FOR EACH LOCATION. PROVIDE LAMPS FOR ALL FIXTURES. VERIFY
CEILING CONSTRUCTION BEFORE ORDERING RECESSED UNITS. PROVIDE PLASTER
FRAMES AND HANGERS AS REQUIRED. CEILING CONSTRUCTION, ARCHITECTURAL
ACCESSORIES, VOLTAGE, AND BALLASTS TO MEET THE EXISTING CONDITION.
H. LIGHTING FIXTURES
1.GROUNDING SHALL COMPLY WITH REQUIREMENTS OF ARTICLE 250. ALL EXPOSED
NONCURRENT CARRYING METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC
RACEWAY SYSTEMS, METALLIC CABLE ARMOR, GROUNDING CONDUCTOR OF
NONMETALLIC SHEATHED CABLES, GROUNDING CONDUCTOR IN NONMETALLIC
RACEWAYS, AND GROUNDED CONDUCTORS OF THE WIRING SYSTEM SHALL BE
GROUNDED.
2.WHEN INDICATED ON THE DRAWINGS, EQUIPMENT GROUNDING CONDUCTORS SHALL
BE EXTENDED FROM THE GROUND BUS IN THE DISTRIBUTION EQUIPMENT TO THE
RECEPTACLE, FIXTURE OR DEVICE LUGS WHERE THEY ARE PROVIDED. WHERE LUGS
ARE NOT PROVIDED, EQUIPMENT GROUNDING CONDUCTORS SHALL BE CONNECTED
TO EQUIPMENT ENCLOSURES. THE CONNECTIONS SHALL BE ARRANGED SUCH THAT
REMOVAL OF THE RECEPTACLE, EQUIPMENT GROUND CONDUCTORS, OR GROUND
JUMPERS FROM GROUND BUSING SHALL NOT AFFECT THE GROUND SYSTEM.
3.RACEWAYS MAY NOT BE USED AS A GROUNDING CONDUCTOR FOR POWER AND
LIGHTING CIRCUITS. ALL CONDUIT SHALL HAVE SEPARATE CODE SIZED GREEN
GROUND WIRE INSTALLED IN THE CONDUIT TO INSURE A CONTINUOUS GROUNDING
PATH.
J. SYSTEM GROUNDING
1.TELEPHONE SYSTEM IS ORDERED AND COORDINATED BY CONTRACTOR AS DIRECTED
BY STARBUCKS.
2.TELEPHONE WALL OUTLETS SHALL BE PROVIDED AT DATA RACK, SAFE AND/OR AS
REQUESTED BY STARBUCKS MANAGER. CONNECT OUTLETS TO TELEPHONE TERMINAL
WITH SEPARATE 3/4" CONDUIT UNLESS OTHERWISE SHOWN ON DRAWINGS. PROVIDE A
TERMINAL MOUNTING BOARD FOR THE INCOMING SERVICE CABLE.
K. TELEPHONE SYSTEM
1.FURNISH AND INSTALL TIME SWITCHES, PHOTOCELLS, CONTACTORS AND FULL
LIGHTING CONTROL SYSTEMS AS REQUIRED FOR LIGHTING CONTROLS INDICATED ON
THE DRAWINGS AND ACCORDING TO APPROVED LOCAL ENERGY CODES.
2.TIME SWITCHES SHALL BE EQUAL TO PARAGON, GENERAL ELECTRIC, TORK, OR
INTERMATIC AND SHALL HAVE SIZE AND NUMBER OF POLES AS REQUIRED.
3.PHOTOCELLS SHALL BE EQUAL TO TORK OR INTERMATIC WITH VOLTAGE AS INDICATED.
L. LIGHTING CONTROL
1.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS
SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE ALL NECESSARY
CORRECTIONS AT NO ADDITIONAL COST TO OWNER.
2.GUARANTEE ALL MATERIAL FURNISHED AND ALL WORKMANSHIP PERFORMED FOR A
PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF WORK. ANY DEFECTS
DEVELOPING WITHIN THIS PERIOD, TRACEABLE TO MATERIAL FURNISHED AS A PART
OF THIS SECTION OR WORKMANSHIP PERFORMED HEREUNDER, SHALL BE MADE GOOD
AT NO EXPENSE TO THE OWNER.
M. GUARANTEE
1.THE ITEMS SPECIFIED HEREIN AND ON DRAWINGS ARE USED AS A STANDARD OF
QUALITY. ANY MATERIALS OF EQUAL QUALITY AND AESTHETIC VALUE WILL BE GIVEN
CONSIDERATION AS A SUBSTITUTE FOR THE MATERIALS SPECIFIED. NO APPROVAL
WILL BE GIVEN TO A SPECIFIC CATALOG NUMBER, MODEL, OR TYPE OF EQUIPMENT,
PRIOR TO BIDDING. AFTER BIDDING, THE DECISION OF THE ARCHITECT AND/OR
ENGINEER DETERMINING EQUAL MATERIALS WILL BE FINAL.
2.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW OF THE
FOLLOWING EQUIPMENT:
A.ELECTRICAL SWITCHGEAR: SWITCHBOARDS, WITH PANELS, MOTOR CONTROL
CENTERS AND SAFETY DEVICES.
B.OVERCURRENT DEVICES: CIRCUIT BREAKERS AND FUSES INCLUDING
TIME/CURRENT TRIP CURVES.
C.LIGHTING FIXTURES: INDOOR/OUTDOOR AS SPECIFIED, PHOTOMETRIC
PERFORMANCE DATA AND LAMPS.
D.DEVICES: SWITCHES, RECEPTACLES, MOTOR CONTROLLERS AND DEVICE
PLATES.
E.LIFE SAFTY/FIRE ALARM SYSTEM: CONTROL PANEL, ANNUNCIATOR PANEL,
INITIATION AND NOTIFICATION DEVICES/APPLIANCES, SYSTEM WIRING
REQUIREMENTS AND DIAGRAM, SYSTEM LOAD CALCS, STANDARD BATTERY
CALCULATIONS, AND AUXILIARY POWER SUPPLY.
3.SUBMIT ITEMS AT ONE TIME IN A NEAT AND ORDERLY MANNER WITHIN 15 DAYS OF
AWARD OF CONTRACT. PARTIAL SUBMITTALS WILL NOT BE ACCEPTABLE.
O. SHOP DRAWINGS AND APPROVALS
1.THE ELECTRICAL CONTRACTOR SHALL MAINTAIN A SET OF DRAWINGS AT THE JOB SITE
FOR THE EXCLUSIVE PURPOSE OF MAINTAINING A RECORD OF ALL WORK INSTALLED
AND TO SHOW ANY DEVIATIONS FROM THE WORK INDICATED ON THE DRAWINGS.
2.AT THE COMPLETION OF THE PROJECT, ONE SET OF REPRODUCIBLE DRAWINGS,
SHOWING ALL AS-BUILT CONDITIONS, SHALL BE DELIVERED TO THE OWNER FOR
ACCEPTANCE PRIOR TO FINAL PAYMENT.
3.DRAWINGS SHALL INCLUDE ACCURATE CONDUIT AND DEVICE LOCATIONS
DIMENSIONED FROM PERMANENT LANDMARKS SUCH AS BUILDING WALLS.
P. RECORD AND AS-BUILT DRAWINGS
1.PROVIDE FLEXIBLE CONNECTIONS TO ALL HVAC EQUIPMENT, WATER HEATER, ETC ANY
EQUIPMENT OVER 20 LB AND/OR MOUNTED ABOVE FINISHED FLOORS.
2.COORDINATE ELECTRICAL REQUIREMENTS FOR ALL PLUMBING AND MECHANICAL
EQUIPMENT WITH FINAL CONTRACTOR SELECTION. THE CONTRACTOR SHALL SIZE
DISCONNECTS BASED UPON CIRCUIT BREAKER RATINGS AND PROVIDE FUSING AS
REQUIRED PER EQUIPMENT MANUFACTURER RECOMMENDATIONS AND U.L. LISTING
REQUIREMENTS.
Q. EQUIPMENT CONNECTIONS
1.WHERE MOTORS ARE INSTALLED IN SUSPENDED CEILINGS, CONTRACTOR SHALL
PROVIDE DISCONNECT SWITCH IN SUSPENDED CEILING WITHIN REACH FROM ACCESS
POINT.
2.SIZING OF MOTOR-RELATED ELECTRICAL COMPONENTS, INCLUDING FEEDER AND/ OR
BRANCH CIRCUITS (WIRE AND CONDUIT) AND OVERCURRENT PROTECTION (BREAKER
AND/ OR FUSES) IS BASED ON RATINGS INDICATED IN THE CONTRACT DOCUMENTS AS
WELL AS NEC APPROXIMATED LOADS FOR A GIVEN MOTOR HORSEPOWER, VOLTAGE
AND PHASE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ACTUAL MOTOR
AND APPLIANCE RATING AND LOADS. CONTRACTOR TO PROVIDE CORRECTLY SIZED
MOTOR OVERLOAD ELECTRICAL COMPONENTS BASED ON NAMEPLATE RATING.
REFLECT ALL CHANGES IN THE AS-BUILT DRAWINGS.
1.CONTRACTOR SHALL ENGAGE THE SERVICES FOR A STATE LICENSED FIRE ALARM
MANUFACTURER/INSTALLER TO PREPARE ALL DESIGN DRAWINGS AND CALCULATIONS
REQUIRED FOR SYSTEM APPROVAL BY THE AUTHORITY HAVING JURISDICTION. SUBMIT
ALL PLANS AND PROVIDE ALL PERMITS REQUIRED FOR A COMPLETE AND OPERABLE
APPROVED LIFE SAFETY SYSTEM.
2.FIRE ALARM DEVICE WIRING SHALL BE MINIMUM #14 AWG COPPER OR PER SYSTEM
MANUFACTURER REQUIREMENTS. PROVIDE MINIMUM 3/4" SEPARATE RACEWAY
SYSTEM OR AS REQUIRED FOR LIFE SAFETY SYSTEM WIRING CONFIGURATION.
3.UPON COMPLETION OF THE INSTALLATION OF LIFE SAFETY SYSTEM WIRING AND
DEVICES, A PERFORMANCE TEST OF THE ENTIRE LIFE SAFETY SHALL BE PERFORMED
TO THE SATISFACTION OF THE AUTHORITY HAVING JURISDICTION.
S. FIRE SYSTEM
1.MUSIC, TELEVISION, VIDEO MOUNTING SYSTEMS ARE NOT SHOWN ON THESE
DRAWINGS AND ARE PROVIDED BY CONTRACTOR THROUGH ARCHITECTS
SCHEDULES/DETAILS. CONTRACTOR TO COORDINATE ALL ROUTING AND FINAL
CONNECTIONS AS APPROVED BY STARBUCKS MAMAGER AS APPLICABLE SPECIFICALLY
TO THIS STORE.
T. LOW VOLTAGE SYSTEMS
1.PERFORM THE EXCAVATION, CUTTING, FITTING, REPAIRING, AND FINISHING OF THE
WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT OF THIS SECTION.
HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL
MEMBERS SHALL BE DONE WITHOUT THE CONSENT OF THE ENGINEER.
2.FINISH ALL SURROUNDING WORK TO THE SATISFACTION OF THE ARCHITECT.
I. EXCAVATION, CUTTING, AND FITTING
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-002
ELECTRICAL NOTES
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-003
ELECTRICAL ENERGY
COMPLIANCE
NEIGHBORING
TENANTS
4,000 SF
STARBUCKS
2,295 SF
9'-2"
7'
-
1
1
3
/
4
"
15'-10 1/4"
25
'
-
1
1
"
6'-2 1/4"
1'
-
4
1
/
4
"
8'-1
3
/
4
"
7'-6
1
/
4
"
1
6
'
-
7
1
/
2
"
Scale: 1/16" = 1'-0"1 ELECTRICAL SITE PLAN
POWER GENERAL NOTES
A.REFER TO THIS SHEET FOR POWER, WIRING, DATA, ETC. INFORMATION
REGARDING EXTERIOR SITE AND SIGNAGE EQUIPMENT ("Y" OR "S" LABELED).
CIRCUIT NUMBERS SHOWN ON THIS DRAWINGS ARE FOR THE EQUIPMENT
WHICH HAS POWER REQUIREMENTS.
B.REFER TO PLUMBING PLANS FOR ADDITIONAL INFORMATION. THIS SHEET IS
PROVIDED FOR REFERENCE ONLY AND TO SHOW LOCATIONS AND TYPES OF
EXISTING ELECTRICAL SERVICES FOR THIS BUILDING.
C.REFER ALSO TO ARCHITECTURAL SITE PLAN.
D.CONDUIT ROUTING IS FOR REFERENCE ONLY, VERIFY LOCATION IN FIELD.
E.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C.
SIGNAGE GENERAL NOTES (UNDER
SEPARATE PERMIT)
A.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN
CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR.
B.CONDUIT ROUTING IS FOR REFERENCE ONLY, VERIFY LOCATION IN FIELD.
C.FOR SIGNAGE, THESE DRAWINGS ARE TO AID IN INSTALLATION OF CONDUIT
AND PREP WORK ONLY. COORDINATE ALL WORK THROUGH SIGNAGE VENDOR.
D.CONDUIT RUNS HAVE BEEN SPECIFIED ON THE SHELL DRAWINGS, COORDINATE
WITH FINAL SIGNAGE VENDOR. THESE PLANS FOR FOR FINAL ELECTRICAL
CONNECTION REQUIREMENTS.
KEYED NOTES
EXISTING ELECTRICAL DISCONNECT SWITCH, METER, AND CT CABINET. SEE
SINGLE LINE DIAGRAM FOR ADDITIONAL INFORMATION.
EXISTING UTILITY TRANSFORMER TO SERVE STARBUCKS. SEE SINGLE-LINE
DIAGRAM FOR ADDITIONAL INFORMATION.
NOT USED.
MENUBOARD, PYLON SIGNAGE AND DRIVE THRU SIGNAGE: PROVIDE 120V
POWER FEED IN EXISTING 1" CONDUIT FROM STARCKBUCKS PANEL INDICATED
VIA TIMECLOCK CONTROLS. COORDINATE WIRE SIZE WITH VOLTAGE DROP PER
ACTUAL ROUTING IN FIELD. PROVIDE MEANS OF DISCONNECT IF NOT PROVIDED
WITH SIGNAGE.
EXISTING 1" CONDUIT FOR VEHICLE DETECTION LOOP. SEE DT SENSOR LOOP
DETAIL ON THIS SHEET.
BUILDING MOUNTED SIGNAGE. EXISTING JUNCTION BOX PROVIDED WITH SHELL.
PROVIDE 120V POWER FEED FROM STARCKBUCKS PANEL INDICATED VIA
TIMECLOCK CONTROLS. COORDINATE WIRE SIZE WITH VOLTAGE DROP PER
ACTUAL ROUTING IN FIELD. PROVIDE MEANS OF DISCONNECT IF NOT PROVIDED
WITH SIGNAGE.
1
2
3
4
5
8'-10"
6'-8"
PLAN VIEW
1'-6"
STONE CURB
5'-0"
A-A SECTION CUT
2"
VEHICLE LOOP DETECTOR
ASPHALT OR
CONCRETE BY LL
LOOP SUPPORT GRAVEL AND SAND
SPEAKER POST
FOOTING PER LL
1/2" PVC 2" LONG TUBING 90 DEGREE BELOW ELBOW
FOR 1/2" PVC TUBING
1/2" PVC 3" LONG TUBING
LEAD WIRE
SLOT PREFAB IF ORDERED LOOP
1.5' WIDE BY 5' LONG
COUPLING FOR 1/2"
PVC TUBING
Scale:NTS2DT SENSOR LOOP DETAIL
LEGEND
LOW VOLTAGE SIDE
DOS CONTROL BOX (DCB)
GRADE
ORDER ZONE
DETECTOR LOOP
DTE POS
WINDOW
BOH
SVC
PANEL
BUILDING INTERIOR
KA
N
E
X
C
A
M
P
O
W
E
R
3/
4
"
-
L
O
O
P
1"
-
L
O
O
P
,
S
P
E
A
K
E
R
,
M
I
C
1"
-
K
A
N
E
X
,
C
A
M
E
R
A
,
S
P
A
R
E
1"
-
D
E
D
I
C
A
T
E
D
P
O
W
E
R
DE
D
I
C
A
T
E
D
P
O
W
E
R
D
E
D
I
C
A
T
E
D
P
O
W
E
R
1/
2
"
-
S
P
E
A
K
E
R
CA
M
E
R
A
C
A
M
P
O
W
E
R
,
M
I
C
DIGITAL ORDER
SCREEN (DOS)
LINE VOLTAGE SIDE
RIGID CONDUIT
FLEX CONDUIT
DOS WHIP
NOTES
1.GC TO INSTALL DCB
2.GC TO PROVIDE AND INSTALL DCB
SUPPORT FRAME, CONCRETE FOOTING
AND ALL NEW RIGID AND FLEXIBLE
CONDUITS.
3.GC TO PROVIDE, INSTALL AND CONNECT
ALL LINE VOLTAGE LINES.
4.GC TO CONNECT DEDICATED POWER
WHIP BETWEEN DOS AND DCB.
5.STARBUCKS VENDOR TO CONNECT ALL
LOW-VOLTAGE WHIPS AND CABLING
BETWEEN DOS AND DCB.
6.POWER TO DOS MAY NOT BE ON EMS
OR LIGHTING CONTROL.
·EMBED UNISTRUT POSTS WHERE APPLICABLE
·ROUTE RIGID CONDUIT THRU FOOTING WHERE
APPLICABLE
CONCRETE FOOTING
Scale:NTS3DCB CONNECTIVITY PLANN
6
S 23747
2
5
Y 225404
Y 225464Y225424
P1A-16 (TIE)
6S22606
6S22606 5
6
P1A-1 (TIE)
S 22606
S 23074
S 237336
P1A-3 (TIE)
S 23105
1
P1A-16 (TIE)
P1A-16 (TIE)
P1A-1 (TIE)
P1A-1 (TIE)
6
P1A-3 (TIE)
6
P1A-5 (TIE)
6
P1A-5 (TIE)
P1A-37
S A (9)
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-006
SITE ELECTRICAL
PLAN
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.RESTROOM 1
RESTROOM 2
DRIVE-THRU
E 16239
29
P1B-31,33
20
6
SEE POS DETAILS
ON SHEET E-502
3
3
Scale: 1/4" = 1'-0"1 ELECTRICAL POWER PLAN
A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM.
B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH
AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL.
C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE VERIFIED WITH OWNER PRIOR TO
ROUGH-IN. PROVIDE G.F.C.I. TYPE RECEPTACLE WITHIN 6 FEET OF ANY SINK.
D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED
EQUIPMENT GROUND CONDUCTOR.
J.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND
COMMUNICATION SYSTEM RECEPTACLES TO BE LOCATED:
- NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR
RECEPTACLE HOUSING, AND
- NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX
OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM.
K.CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE CIRCUIT IS TO BE REPLACED OR
RELOCATED, CONTRACTOR IS TO VERIFY CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE.
L.ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR DEVICES SHALL BE LOCATED A
MINIMUM OF 15" ABOVE THE FINISHED FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF
48" ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX.
K.EACH AND EVERY 120VAC., 15 AND 20 AMP, 1 PH., RECEPTACLE IN KITCHEN, FOOD PREPARATION, BAR AREAS
AND RESTROOMS SHALL BE GFCI TYPE PROTECTION. 210.8(B). ANY RECEPTACLE INSTALLED WITHIN 6 FEET
OF A SINK MUST BE G.F.C.I. TYPE. GFCI DEVICES MUST BE REMOTELY ACCESSIBLE.
GENERAL NOTES
E 23424
N
30
30
KEYED NOTES
1.ESPRESSO MACHINE: PROVIDE RECEPTACLE MOUNTED AT 30"
AFF; FIELD VERIFY NEMA CONFIGURATION REQUIRED.
2.ICE MACHINE: RECEPTACLES AND CONNECTIONS PER 'E'
SCHEDULE ON THIS SHEET. CONFIRM ELECTRICAL
REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH-IN.
3.FLOOR POWER/DATA: SEE PENETRATION PLAN FOR EXACT
DIMENSIONING AND LOCATION.
4.CUP LABELER OR MOBILE ORDER PRINTER: PROVIDE
RECEPTACLE AND BACKBOX FOR DATA OUTLET AT 26" AFF.
ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR
MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA
CABLING AND PROVIDE PULL STRING FROM END TO END.
5.SIGNAGE OUTLET, PROVIDE W/IN 18" OF THE TOP OF WINDOW.
6.POS: FURNISH AND INSTALL DOUBLE-DUPLEX MOUNTED @ 18"
AFF PROVIDE DEDICATED GROUND WIRE BACK TO SERVING
PANEL. INSTALL (1) J-BOX FOR DATA OUTLET AND (1) J-BOX
FOR PHONE OUTLET AT 18" AFF. SEE DETAILS ON E-501/E-502.
7.GRINDER AND SCALE: PROVIDE RECEPTACLE MOUNTED
BELOW COUNTER.
8.ALL BACK BAR AND FRONT BAR J-BOXES AND OUTLETS SHALL
BE SURFACE MOUNTED. PROVIDE CONDUITS AS NEEDED AND
(1) ADDITIONAL SPARE CONDUIT BETWEEN ALL J-BOXES FOR
FUTURE ELECTRICAL REQUIREMENTS. ALL J-BOXES SHALL BE
POSITIONED TO AVOID OBSTRUCTION OF ANY EQUIPMENT
SUCH AS REFRIGERATORS AND DISHWASHERS.
9.OVEN COMBI: CONFIRM NEMA CONFIGURATION AND MOUNTING
HEIGHT.
10.BLENDER: PROVIDE RECEPTACLE MOUNTED BELOW COUNTER.
11.RECEPTACLE FOR FUTURE USE. COORDINATE EXACT
LOCATION AND MOUNTING HEIGHT WITH OWNER'S
REPRESENTATIVE.
12.DATA OUTLET FOR FUTURE USE: PROVIDE BACKBOX FOR DATA
OUTLET MOUNTED AT 26" AFF. ROUTE 3/4" CONDUIT FROM
BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION.
LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL
STRING FROM END TO END.
13.BLENDER PITCHER RINSER: PROVIDE RECEPTACLE MOUNTED
AT 26" AFF. COORDINATE EXACT LOCATION WITH OWNER'S
REPRESENTATIVE.
14.UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE
MOUNTED BELOW COUNTER.
15.COORDINATE EXACT LOCATION AND MOUNTING HEIGHT(S) OF
ALL CONVENIENCE RECEPTACLES WITH OWNER'S
REPRESENTATIVE.
16.CLOVER BREWER: PROVIDE RECEPTACLE MOUNTED AT 48"
AFF; VERIFY NEMA CONFIGURATION REQUIRED.
17.WARMING OVEN: PROVIDE NEMA 6-30R RECEPTACLE MOUNTED
AT 26" AFF.
18.NITRO EQUIPMENT: PROVIDE RECEPTACLE MOUNTED BELOW
COUNTER.
19.COORDINATE EXACT LOCATION AND CONNECTION
REQUIREMENTS FOR BANQUETTE SEATING WITH OWNER'S
REPRESENTATIVE.
20.PROVIDE 4-SQUARE J-BOX FOR "STROBE LOCATION J-BOX".
SEE DETAIL ON E-501.
21.PROVIDE NECESSARY CONDUIT FOR POWER AND DATA
OUTLETS TO MANAGER'S DESK LOCATION. SEE REQUIRED
POWER AND DATA OUTLETS ON DETAIL ON E-501/E-502.
22.PROVIDE RECEPTACLE AND DATA OUTLET CENTERED
HORIZONTALLY FOR FUTURE DIGITAL MENU BOARD. PROVIDE
BACKBOX FOR DATA OUTLET. ROUTE 3/4" CONDUIT FROM
BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION.
LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL
STRING FROM END TO END. SEE ARCHITECTURAL ELEVATIONS
FOR MENU BOARD LOCATIONS.
23.RECIRC PUMP - PROVIDE MOTOR RATED DISCONNECT SWITCH
AND CONTROL VIA TIMECLOCK.
24.PROVIDE RECEPTACLE ABOVE REACH-IN
REFRIGERATOR/FREEZER. FIELD VERIFY LOCATION.
25.PROVIDE OUTLETS AND COMMUNICATIONS FOR DRIVE THRU
AND CASH REGISTER POS EQUIPMENT. SEE DATA DEVICE
SCHEDULE ("A" LABELED) ON THIS SHEET. COORDINATE WITH
ARCHITECTURAL AND STARBUCKS.
26.POS PRINTER: PROVIDE DATA BACK-BOX. ROUTE 3/4" CONDUIT
FROM BACK-BOX TO DATA RACK NEAR MANAGER'S
WORKSTATION.
27.DRIVE-THRU (DTP) OUTLETS. REFER TO DRAWING E-501/E-502
FOR MORE INFORMATION AND CIRCUITING.
28.MANAGER'S DESK/IT RACK OUTLETS. REFER TO DRAWING
E-501/E-502 FOR MORE INFORMATION AND CIRCUITING.
29.PASTRY CASE: PROVIDE RECEPTACLE; FIELD VERIFY NEMA
CONFIGURATION AND MOUNTING HEIGHT REQUIRED PRIOR TO
ROUGH-IN.
30.LOCATION OF EXISTING HVAC EQUIPMENT (PROVIDED IN
SHELL). DASHED LINES INDICATES ON ROOF. MAINTAIN
EXISTING CIRCUIT.
31.LOCATION OF HVAC EQUIPMENT SEE MECHANICAL
FEEDER/CONNECTION SCHEDULE ON THIS SHEET. DASHED
LINES INDICATES ON ROOF.
32.LED LIGHT STRIP: REFER TO SHEET "E-102" FOR LIGHTING INFO
AND LIGHTING ITEM NUMBER. SPECIFIC LED STRIP
CONNECTION SHOWN HERE FOR CLARITY. REFER TO
ARCHITECTURAL DETAILS FOR ADDITIONAL MOUNTING
INFORMATION.
GFCI
P1A-12
P1B-28,30
31
T/USB T/USB
19
(TYPICAL OF 6)
P1B-13
(TIE)
T/USB T/USB T/USB T/USB
15USB 15USB 15USB
E 1026714
P1B-1
24
E 11083
24
E 11083 P1B-3
24
E 13682
P 22642
P1B-8
P 22642
P1B-10
P 22642
P1B-12
E 12618 14
P1A-15
(TIE)
P1A-15
(TIE)
E 12618 14
18
E 21679
E 20010
P1B-9 18
E 10808
E 22885
7
16
11
12
12
P1B-32,34
P1B-2
A 22970
A 10076
A 10022
A 10007
A 10005
A 10002
21 26
P1A-15
(TIE)E 10267
27
14
25
GFCI
15
P1A-15
(TIE)
E 12508
10
P1A-14P1A-17E1026714
E 10267 14
E 15186
P1A-39,41
E 23421
E 23182
2
P1B-6
E 1756413
P1B-4
E 197421
P1B-36,38 P1B-40,42
E 19742
1
E 20032(2)
P1B-35,37
17
12
P1B-39,41(3)E 23419 P1B-7
E 23442 9
P1A-29,31,33
E 23444
P1A-28,30
P 12501
P 13082
P1B-17
23SEE DETAIL 1/P501
FOR REC LOCATIONS
P1B-43
P1B-15
P1A-13
E 1026714
E 1026714
E 10267
14
A 10075 4
12
12
P1A-13
P1A-13
P1A-13
P1A-13
P1A-32,34,36
P 11109
P1A-15
(TIE)
EXISTING
PANEL 'P1A'
EXISTING
PANEL 'P1B'
P1A-12
P TK0045
A 14678
A 14677
A 22725
A 10012
A 10014A22726
P1B-14
30
A 22970
P1B-5
P1B-5
P1B-23
P1B-11
(TIE)
P1B-11
(TIE)
P1B-11
(TIE)
P1B-13
(TIE)
P1B-13
(TIE)
P1B-25,27,29
P1B-22,24,26
P1B-16,18,20
P1B-21
5
5
5 5
31
31
8
22
28
208V
1PH
NOTE:
1.SEE EQUIPMENT SCHEDULE "E" ON THIS SHEET, FOR ADDITIONAL INFORMATION.
2.DISCONNECT SWITCH AND CONVENIENCE RECEPTACLE IS PROVIDED WITH UNIT.
3.CIRCUIT DUCT DETECTOR TO P1A- AND LOCATE REMOTE TEST STATIONS PER OWNER AND
AHJ. PROVIDE HORN/STROBE AS REQUIRED BY AHJ AND LOCATED PER OWNER/AHJ.
4.CONFIRM ALL REQUIREMENTS PRIOR TO ROUGH-IN.
5.CONTROL VIA TIMECLOCK FOR OCCUPIED HOURS.
MECHANICAL FEEDER/CONNECTION SCHEDULE
ITEM VOLTAGE M.C.A.
FEEDERS TYPE OF
CONN
BRANCH
BREAKER/
SWITCHWIRECOND
REMARKS
200A-2P142EXISTING
RTU-1
120V
1PH 15A-1P-EXISTING
EF-1
NOTES
5
NOTES
2,3EXISTING
208V
1PH 150A-2P116EXISTING
RTU-2
NOTES
2,3
208V
1PH
3#6THHN
1#10 G 1"THRU 60A DS 45A-2P27.1CU-1 NOTES
1,4
120V
1PH 15A-1P-15A DISCONNECT
SWITCHAC-1 2#12THHN
1#12 G 1/2"
208V
3PH 35A-3P26.5 35A DISCONNECT
SWITCHAC-2 3#8THHN
1#10 G 3/4"
208V
3PH
3#8THHN
1#10 G 3/4"THRU 60A DS 40A-3P30.8AC-3
CKT-1
NOTES
1,4
208V
3PH
3#10THHN
1#10 G 3/4"THRU 30A DS 30A-3P22.2AC-3
CKT-2
NOTES
1,4
NOTES
1,4
NOTES
1,4
P1B-44
(TIE)
EXISTING
EXISTING
EXISTING EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
3111
P 23355
P1B-19
P1A-44
P TK0045
P1A-15
P1A-13
P1B-44
(TIE)
A 100754
A 10075
4
A 100754
E 12508
E 23421
P1B-45
10
(Dimmer "d")
L 22440
32
(≈28'-6")
P1A-18 (TIE)
28
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-101
POWER PLAN
Scale: 1/4" = 1'-0"1 ELECTRICAL LIGHTING PLAN
KEYED NOTES
1.SWITCHBANK. REFER TO SWITCH BANK DETAIL 2 ON THIS SHEET AND LIGHTING
CONTROL DIAGRAM ON SHEET E-601.
2.EMERGENCY/EXIT FIXTURE. GC TO PERFORM TEST TO ENSURE EMERGENCY
BATTERY UNIT WILL PROVIDE BACKUP POWER FOR MINIMUM 90 MINUTES.
3.NOT USED.
4.NOT USED.
5.NOT USED.
6.WALL MOUNTED MOTION SENSING CONTROL (LEVITON IPS02 1LW) SHALL
CONTROL LIGHTING IN THIS ROOM. SET FOR 5 MINUTE DELAY.
7.LED LIGHT STRIP: REFER TO ARCHITECTURAL DETAILS FOR ADDITIONAL
MOUNTING INFORMATION.
8.FIXTURE PROVIDED WITH EMERGENCY BATTERY BACK UP, SEE LIGHTING
FIXTURES SCHEDULE 'L' FOR MORE INFORMATION.
GENERAL NOTES
A.REFER TO THIS SHEET FOR LIGHTING FIXTURE SCHEDULE AND E600 FOR PANEL
SCHEDULES. REFER TO LUTRON DRAWINGS IN THIS PACKAGE FOR LIGHTING
CONTROLS.
B.PROVIDE A DISCONNECTING MEANS FOR EACH MULTI-WIRE BRANCH CIRCUIT IN
ACCORDANCE WITH NEC 410.130(G)(1) THROUGH (3). DISCONNECTING MEANS SHALL
BE LOCATED AT POINT WHERE CIRCUIT ORIGINATES AND SHALL SIMULTANEOUSLY
DISCONNECT ALL UNGROUNDED CONDUCTORS.
C.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND
ELEVATION OF ALL LIGHTING FIXTURES.
D.THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING FIXTURES
AND MANUFACTURERS' CATALOG NUMBERS. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL
REFLECTED CEILING PLAN AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY
TRIMS AND MOUNTING HARDWARE.
E.COORDINATE EXACT LIGHTING FIXTURE LOCATIONS WITH ELECTRICAL,
MECHANICAL, PLUMBING EQUIPMENT, INCLUDING CONDUIT, PIPING, DUCTING, ETC.
PRIOR TO ROUGH-IN.
F.ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED STRUCTURAL
SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED ISSUE OF THE CALIFORNIA
BUILDING CODE, AS WELL AS ANY LOCAL CODES.
G.ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL
CONDUCTOR FOR EACH ZONE/CHANNEL.
H.ALL FLUORESCENT DIMMING ZONES/CHANNELS SHALL BE PROVIDED WITH 3 LINE
VOLTAGE CONDUCTORS (NEUTRAL, DIMMED HOT, SWITCHED HOT) OR 2 LINE
VOLTAGE CONDUCTORS/2 CONTROL CONDUCTORS AS REQUIRED BY THE
CONTROL/BALLAST TYPE.
I.'EM' EMERGENCY EGRESS LIGHT TO BE PROVIDED WITH 90 MINUTE BATTERY
BACKUP (EITHER NEW WITH FIXTURE OR RETROFITTED ONTO EXISTING). INTENT IS
TO ENSURE 1.0 FOOT CANDLES AT WALKING SURFACE. GC SHALL CONFIRM
CONFORMANCE THROUGH METERING.
J.ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT
HOT CONNECTION TO THE CHARGING LEAD OF THE LOCAL AREA CIRCUIT.
K.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN CHEVRONS
AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES BETWEEN EXIT SIGNS
SHOWN ON THE ELECTRICAL AND ARCHITECTURAL PLANS SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT PRIOR TO ORDERING EXIT SIGNS. A JUNCTION
BOX MUST BE PROVIDED WITH ALL EXIT LIGHTS CONNECTED TO MORE THAN ONE
SET OF CONDUCTORS UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN
APPROVED OUTLET BOX FOR THROUGH WIRING.
L.ALL LOW VOLTAGE LIGHTING SYSTEMS SHALL COMPLY WITH 2016 CEC ART. 411 AND
SHALL BE LISTED PER 411.3 OR LOCAL CODES HAVING JURISDICTION.
M.ALL ELECTRICAL EQUIPMENT LOCATED OUTSIDE SHALL BE WEATHERPROOF.
N.ALL LOW VOLTAGE WIRING NOT RUN IN CONDUIT SHALL BE PLENUM RATED.
O.MOUNT ALL SWITCHES, CONTROLS, RECEPTACLES BETWEEN 15"- 48" AFF.
N
L 21772(2)
L 21772(2)
L 21772(2)
EM
8
L 15057(7)EM
8
L 15057(2)
L 21772 (4)
L 21772 (6)
L 20831(3)
L 21772 (37)
L 21772(24)
L X2851 L X2851
(Dimmer "d")L 22216 7
(≈20'-9")
(Dimmer "d")L 22216 7
(≈28')
OS
6
OS
6
P1A-18
(TIE)
EM
8
(Dimmer "e")
EM
8 EM
8
EM
8
EM
8
EM
8
EM
8
EM
8
EM
8
(Dimmer "a")
P1A-18 (TIE)
(Dimmer "b")
(Dimmer "h")
(Dimmer "f")
(Switch "g")
1
P1A-18 (TIE)
P1A-18 (TIE)
P1A-18 (TIE)P1A-18 (TIE)
P1A-18 (TIE)
P1A-18
(TIE)
P1A-18 (TIE)
P1A-18 (TIE)
(Dimmer "c")
P1A-18 (TIE)
EXISTING
PANEL 'P1A'
EXISTING
PANEL 'P1B'
(Dimmer "d")L 22440 7
(≈6'-10")P1A-18 (TIE)
L 19049
L 19049
2
2
1
A 10015 4 A 10015 4
Scale:NONE2SWITCH BANK DETAIL
DS
"a"
DS
"b"
DS
"c"
S
"e"
DS = DIMMER SWITCH
S = NON DIMMING SWITCH
LEGEND:
DIMMER SWITCH CONTROL:
DS "b" = Cafe Lighting
DS "d" = Cafe/Engine Strip Lighting
DS "a" = Engine Lighting
DS "e" = Restroom Vestibule Lighting
DS "f" = Engine Pendant
DS
"d"
DS "c" = Cafe Accent Lighting DS
"f"
S "g" = Workroom
S
"g"
S
"h"
DS "h" = Cafe Sconce Lighting
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-102
LIGHTING PLAN
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.RESTROOM 1
RESTROOM 2
PATIO
DRIVE-THRU
Scale: 1/4" = 1'-0"1 ELECTRICAL LOW VOLTAGE PLAN N
A.CONDUITS SHALL, (a) CONTAIN NO CONTINUOUS SECTIONS
LONGER THAN 30M (98FT), AND, (b) CONTAIN MORE THAN (2) 90
DEGREE BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A
PULLBOX. CONDUITS IN PLACE OF PULL BOXES IS
UNACCEPTABLE.
B.CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE
RATED AT 20 LB.
C.CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES OF
THE INTERNAL CONDUIT DIAMETER FOR CONDUITS 2" IN
DIAMETER OR LESS, AND (b) 10 TIMES THE INTERNAL CONDUIT
DIAMETER FOR CONDUITS MORE THAN 2" IN DIAMETER.
D.TERMINATE CONDUITS THAT PROTRUDE THROUGH STRUCTURAL
FLOORS 3" ABOVE THE FLOOR SURFACE.
E.INSTALL BUSHINGS AND BELL ENDS AS REQUIRED ON ALL
CONDUITS.
F.FLEX CONDUIT IS GENERALLY UNACCEPTABLE FOR USE AS A
COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC JOINTS AND
AS APPROVED IN WRITING BY THE ENGINEER.
G.ALL SUB SLAB CONDUITS SHALL BE INSTALLED IN A MATTER
THAT PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO ENSURE RAIN WATER
OR CONSTRUCTION WATER IS PREVENTED FROM ENTERING
AND/OR REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT
OF COMMUNICATION CABLES.
H.ALL PULL BOXES SHALL BE SIZED AND INSTALLED PER
ANSI/TIA/EIB-569A. PULL BOXES FOR UNDER FLOOR CONDUIT
RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULL
BOXES FOR OVERHEAD CONDUIT RUNS SHALL BE LOCATED
ABOVE ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING
SPACE.
I.CONDUIT(S) SHALL EXIT A PULL BOX ON THE WALL OPPOSITE
THE WALL ENTERED.
J.IF FIRE ALARM DEVICES ARE INDICATED ON PLANS, THEN THE
ELECTRICAL CONTRACTOR SHALL SUBMIT FIRE ALARM PLANS
AND OBTAIN APPROVAL PRIOR TO INSTALLATION.
GENERAL NOTES
1.SAFE: PROVIDE RECEPTACLE ON DEDICATED CIRCUIT.
ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR
SECURITY ALARM JACK AND ROUTE CONDUIT BACK TO
SECURITY PANEL J-BOX. REFER TO MANAGER'S DESK
DETAIL AND POS DETAIL ON E-501/E-502 FOR ADDITIONAL
INFORMATION.
2.PROVIDE RECEPTACLE ON DEDICATED CIRCUIT.
ADJACENT TO RECEPTACLE, PROVIDE J-BOXES FOR
TELEPHONE AND DATA. ROUTE CONDUIT(S) BACK TO
MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL
AND POS DETAIL ON E-501/E-502 FOR ADDITIONAL
INFORMATION.
3.STUB UP POWER, DATA PHONE AND/OR SECURITY
CONDUITS 6" AFF TO SERVE NEARBY DEVICES IN THIS
LOCATION. ROUTE POWER CONDUCTORS IN FLEXIBLE
METAL CONDUIT CONCEALED OR TIGHT-TO-WALL FROM
RECEPTACLES TO NEARBY RIGID STUB UP AND BACK TO
SERVING POWER PANEL. ROUTE DATA, PHONE AND SAFE
CONDUITS UNDER FLOOR BACK TO DATA RACK NEAR
MANAGER WORKSTATION. PROVIDE AN END-TO-END PULL
STRING IN ALL DATA PHONE AND SAFE CONDUITS. LABEL
EACH END OF PULL STRING WITH CONDUIT SYSTEM ("POS",
"SECURITY", ETC..) AND DESTINATION ("DRIVE-THRU",
"FRONT BAR", ETC..). PROVIDE INSULATED BUSHINGS ON
ALL STUBBED-UP AND EXPOSED CONDUIT ENDS. REFER
TO ARCHITECTURAL PENETRATION PLAN FOR ADDITIONAL
INFORMATION.
4.CUP LABELER AND/OR MOBILE ORDER PRINTER: PROVIDE
RECEPTACLE AND ADJACENT DATA BACKBOX AT SAME
MOUNTING HEIGHT - COORDINATE LOCATION AND
MOUNTING HEIGHT WITH OWNER'S REPRESENTATIVE
PRIOR TO ROUGH IN. ROUTE 3/4" CONDUIT FROM BACKBOX
TO DATA RACK NEAR MANAGER'S WORKSTATION.
5.DT POS AND EXPEDITER TILL MONITOR: PROVIDE DOUBLE
DUPLEX RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT
TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE
CONDUIT BACK TO MANAGER'S DESK. REFER TO
MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON
E-501/E-502 FOR ADDITIONAL INFORMATION.
6.DT EXPEDITER MONITOR: PROVIDE DOUBLE DUPLEX
RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX
FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK.
REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS
DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION.
7.DT TIMER CONTROL UNIT AND MONITOR: PROVIDE DOUBLE
DUPLEX RECEPTACLE. ADJACENT TO RECEPTACLE,
PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO
MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL
AND DRIVE-THRU POS DETAIL ON E-501/E-502 FOR
ADDITIONAL INFORMATION.
8.DT TIMER SIGNAL PROCESSOR: PROVIDE DUPLEX
RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX
FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK.
REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS
DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION.
9.WIRELESS HEADSET BASE STATION: PROVIDE DUPLEX
RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX
FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK.
REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS
DETAIL ON E-501/E-502 FOR ADDITIONAL INFORMATION.
10.TELEPHONE AND DATA OUTLETS FOR MANAGER'S DESK:
REFER TO MANAGER'S DESK DETAIL ON E-501/E-502 FOR
ADDITIONAL INFORMATION.
11.CARBON MONOXIDE DETECTOR AND THERMOSTATS FOR
ROOF TOP HVAC UNITS: COORDINATE INSTALLATION AND
CONNECTION WITH MECHANICAL CONTRACTOR.
COORDINATE LOCATION(S) WITH OWNER'S
REPRESENTATIVE. VERIFY LOCATIONS/CONNECTIONS
PRIOR TO INSTALLATION.
12.DATA OUTLET FOR FUTURE USE: PROVIDE BACKBOX
MOUNTED AT 26" ROUTE 3/4" CONDUIT FROM BACKBOX TO
DATA RACK NEAR MANAGER'S WORK STATION. LABEL
CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING
FROM END TO END.
13.PROVIDE RECEPTACLE AND DATA OUTLET CENTERED
HORIZONTALLY BEHIND MENU BOARD FOR FUTURE
DIGITAL MENU BOARD. PROVIDE BACKBOX FOR DATA
OUTLET. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA
RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT
FOR DATA CABLING AND PROVIDE PULL STRING FROM END
TO END. SEE INTERIOR ELEVATIONS FOR MENU BOARD
LOCATIONS.
14.NOT USED.
15.NOT USED.
16.RECESSED SPEAKER. CONFIRM FINISH.
17.AMPLIFIER: LOCATE ON SHELVING ABOVE MANAGER'S
WORKSTATION (SEE DETAIL ON E-501/E-502).
18.CONDUIT PATHWAY ABOVE CEILING FOR FUTURE
ANTENNA COAXIAL MINIMUM 1-14" CONDUIT WITH THICK
END-TO-END PULL STRING. MINIMUM 8-1/2" RADIUS BENDS,
MAXIMUM 100'-0" RUN, NO CONSECUTIVE 90-DEGREE
BENDS. TERMINATE AT J-BOX WITH COVER PLATE AT
CEILING/WALL WITHIN 2'-0" OF BUMP BASE STATION AND
ABOVE BOH CEILING ADJACENT FUTURE PENETRATION
ZONE.
19.THIS CONFIGURATION IS TYPICAL OF DRIVE-THRU DATA
REQUIREMENTS AND EQUIPMENT. COORDINATE EXACT
REQUIREMENTS OF RELOCATED EQUIPMENT WITH
OWNER'S REPRESENTATIVE.
20.THIS CONFIGURATION IS TYPICAL OF POS STATION DATA
REQUIREMENTS AND EQUIPMENT. COORDINATE EXACT
REQUIREMENTS OF RELOCATED EQUIPMENT WITH
OWNER'S REPRESENTATIVE.
KEYED NOTES
17
A 10076
A 10002
A 10005
A 10007
A 10022 11
10 10
A 14678
A 14677
A 22725
A 10012
A 12336A22726
5 9678
19
4 2
2
1
20
2
13
A 22970(3)
A 10015 A 10015
12
A 10075 A 10075
4 4
A 100754
12
12
12
12
12
EXISTING
PANEL 'P1A'
EXISTING
PANEL 'P1B'
13
A 22970
1616
12 A 10075
4
3
3
12
12
18
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-103
LOW VOLTAGE
DESIGN PLAN
.
15
0
M
M
.
15
0
M
M
6"
6"
9-1/2"
(240MM)
Scale: 3/4" = 1'-0"2 WATER FILLING STATION - ELECTRICAL
Scale: 3/4" = 1'-0"3 ICE MACHINE - ELECTRICAL
Scale: 3/4" = 1'-0"4 REFRIGERATOR/FREEZER - ELECTRICAL
2
2
2
SECURITY CONTROL
ALARM PANEL
WIRELESS MODEM AT 84" (2130MM)
A.F.F. STARBUCKS VENDOR TO
DETERMINE OPTIMAL DEVICE
LOCATION
EMS DATA CONCENTRATOR. ALLOW 2" (50 MM) IN. CLEAR ABOVE
POWER & DATA RECEPTACLES
AT 60" (1525MM) A.F.F. TO CENTER
OF GROUPING. SEE NOTE 'C' ABOVE
FOR DESCRIPTION.
HOME PHONE CONNECT (HPC)
CORDLESS 1 LINE PHONE
OFFICE PC
IPOD TOUCH
CHARGING
CRADLE
POWER, TELEPHONE & DATA
RECEPTACLES AT 12" (305MM) A.F.F. TO
CENTER OF GROUPING. SEE NOTE 'A'
ABOVE FOR DESCRIPTION
DEMARC, IF REQUIRED
POWER AND DATA RECEPTACLES
AT 80" (2030MM) A.F.F. TO CENTER
OF GROUPING. SEE NOTE 'B'
ABOVE FOR DESCRIPTION
WALL MOUNTED SHELVING UNIT
ATTACHED TO BACKER BOARD
MUSIC SYSTEM PLAYER AND AMPLIFIER
(FURNISHED BY OWNER, INSTALLED
WITH SPEAKER SYSTEM BY GC) ON 14"
DEEP (355MM) SHELF ONLY (MIN.)
(NOT IN EQUIP. RACK).
ELEVATION VIEW 1
UPS
IPS EQUIPMENT
ROUTER
EQUIPMENT RACK SCHEDULE NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED
AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE.SECURITY RECORDER (NVR)
SECURITY KEYBOARD
NETWORK SWITCH
PATCH PANEL
PRODUCTION CONTROLLER DEVICES
BOH CEILING. REFER TO REFLECTED
CEILING PLAN(S) FOR ACTUAL HEIGHT.
PRINTER
78" W X 96" H (1980MM W X
2440MM H) MIN. 3/4" FIRE RATED
PLYWOOD BACKER BOARD.
FASTEN TO STRUCTURE TO
HOLD MIN. 350 PSF. PAINTABLE
SURFACE ON ROOM SIDE &
FINISH AS SCHEDULED.
SECURITY MONITOR
MOUNTED ON MONITOR
ARM (ATTACHED TO
BACKER BOARD).
ROLLING
CART
4'
-
0
"
(
1
2
2
0
M
M
)
A.
F
.
F
.
EQUIPMENT RACK (SIDE VIEW).
SEE ELEVATION 2 FOR MORE
INFORMATION
DESK
SHELVING ABOVE
POWER & DATA RECEPTACLES
(IN WALL, ABOVE SHELVES)
(1) QUAD RECEPTACLE FOR:
EMS DATA CONCENTRATOR
(1) DUPLEX RECEPTACLE FOR:
SECURITY CONTROL ALARM PANEL
(1) 2-DATA PORT FOR:
EMS DATA CONCENTRATOR
POWER & DATA RECEPTACLES
(IN WALL, AT MUSIC SYSTEM SHELF)
(1) DUPLEX RECEPTACLE FOR:
MUSIC SYSTEM AMPLIFIER AND
FUTURE USE
(1) 2-DATA PORT FOR:
CURIO
POWER, TELEPHONE & DATA RECEPTACLES
(IN WALL, BELOW DESK)
(1) QUAD RECEPTACLE FOR:
PC, PRINTER, PHONE AND HPC
(1) QUAD RECEPTACLE FOR:
LAPTOP, CASH SCALE AND FUTURE USE
(1) QUAD RECEPTACLE
(1) PHONE MAIN
(1) 2-DATA PORT FOR:
PC AND PRINTER
DESK
A
B
C
1"
50MM
EQ EQ
CASH
SCALE
2'-2-1/4"
(760MM)PLAN VIEW
2'
-
6
"
(
7
6
0
M
M
)
.
(3) SLEEVES FOR LOW
VOLTAGE CABLE BUNDLES
MOUNTED TO (2) UNISTRUTS
EQUIPMENT RACK
D POWER RECEPTACLES
(IN WALL, AT BACK OF EQUIPMENT RACK)
(1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR:
UPS
(1) DUPLEX RECEPTACLE FOR:
PDU STRIP AND FUTURE USE
ROLLING CART (BELOW)
MAINTAIN 24" (610MM) MIN.
CLEARANCE FOR WHEN
EQUIPMENT RACK IS IN
OPEN ACCESS POSITION
2'-6"(760MM)MINI GROUND BAR FOR EQUIMENT RACK. GC TO
COORDINATE RACK GROUNDING TO BAR WITH #6 GROUND
WIRE AND PER JURISDICTIONAL REQUIREMENTS
ELEVATION VIEW 2
43" W X 42" H (1090MM W X
1070MM H) MIN. 3/4" FIRE RATED
PLYWOOD BACKER BOARD.
FASTEN TO STRUCTURE TO HOLD
MIN. 350 PSF. PAINTABLE SURFACE
ON ROOM SIDE & FINISH AS
SCHEDULED.
PRINTER.
ROLLING CART
EQUIPMENT RACK WALL MOUNTED
TO STRUCTURE BY STARBUCKS
VENDOR (GC TO COORDINATE
INSTALLATION). GROUND RACK
PER MFR'S ASSEMBLY
INSTRUCTIONS. SEE EQUIPMENT
RACK SCHEDULE BELOW FOR
EQUIPMENT INCLUDED WITHIN.
SECURE
KEY BOX
LOW VOLTAGE CABLE BUNDLES
SECURITY PANEL
FUTURE USE
- - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - -
2 SECURITY
321
..
4"
100MM
ENLARGED VIEW
(3) 3" (76 MM) Ø
SLEEVES FOR
LOW VOLTAGE
CABLE BUNDLES
MOUNTED TO
(2) UNISTRUTS
LAY-IN
CEILING
CEILING TRIM
RING (TYP.)
1 MUSIC
PLAY NETWORK
SPEAKERS
- - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - -
3 POS
HIGH SPEED INTERNET
DEMARC EXTENSION
POS LAN
DT TIMER
1'-0"
305MM
MOUNT GROUND BAR
AT 92" (2335MM) A.F.F.
MOUNT EQUIPMENT RACK
AT 62" (1575MM) A.F.F.
MAINTAIN 24" (305MM) MIN. CLEAR
FOR EQUIP. RACK IN OPEN ACCESS
POSITION) ACCESS. SEE PLAN
VIEW ABOVE
POWER & DATA RECEPTACLES AT
75 1/2" (1920MM) A.F.F. TO CENTER
OF GROUPING. SEE NOTE 'D'
ABOVE FOR DESCRIPTION.
1"
25MM
ENLARGED VIEW
IOT GATEWAY.
.
PROVIDE MIN. 18"
(460MM) CLEAR ABOVE
EQUIPMENT RACK TO
UNDERSIDE OF CEILING
FOR VENTILATION
Scale: 3/4" = 1'-0"1 MANAGERS DESK, EQUIPMENT RACK - ELECTRICAL
P1A-19
MANAGER'S
DESK #1
MANAGER'S
DESK #2
P1A-21
P1A-23
MANAGER'S
DESK #3
P1A-25
P1A-27
EQUIPMENT
RACK #2
EQUIPMENT
RACK #1
RECEPTACLE
FOR ICE
MACHINE AT 72"
(1830MM) A.F.F.
6" (152MM)
MIN. CLEAR
TO BACK
WALL
BACK WALL
.
RECEPTACLE
FOR FUTURE
USE AT 72"
(1830MM) A.F.F.
ICE BIN
DEDICATED
RECEPTACLE FOR
INSTANT HOT
WATER BOILER AT
26" (660MM) A.F.F.
8"
(200MM)
DUPLEX
RECEPTACLE AND
DATA PORT AT 47"
(1190MM) A.F.F.
SHELVING ABOVE
RECEPTACLE FOR
REFRIGERATOR
AND/OR FREEZER
AT 84" (2135MM)
AFF
BACK WALL
Scale: 3/4" = 1'-0"6 CBE ELECTRICAL
UNDERCOUNTER
REFRIGERATORS
UNDERCOUNTER
NITROGEN
GENERATOR
UNDERCOUNTER
NITRO
REFRIGERATOR
UNDERCOUNTER
REFRIGERATORS
2 22
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR BLENDER(S)*
RECEPTACLE FOR
LABEL PRINTER
2-DATA PORT FOR
LABEL PRINTER
2-DATA PORT FOR
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28" (711MM)
TO TOP OF RECEPTACLE A.F.F.RECEPTACLE FOR
UNDERCOUNTER
NITROGEN
GENERATOR
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
BLENDER(S)*
RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
REFRIGERATORS
DEDICATED
RECEPTACLE FOR
ESPRESSO MACHINE
DEDICATED
RECEPTACLE FOR
INSTANT HOT WATER
BOILER
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
IoT MODULE FOR
ESPRESSO MACHINE,
FOIO (TYP. 1 OF 2)
(2) RECEPTACLES FOR LABEL PRINTERS AND/OR CONNECT DEVICES
2-DATA PORT FOR LABEL PRINTERS AND/OR CONNECT DEVICES
2-DATA PORT FOR FUTURE USE
POWER AND DATA RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F.
21” X 3” (533MM X 76MM) STUB-UP
PENETRATION AREA. SUPPLY
POWER AND DATA CONDUIT FOR
ESPRESSO MACHINES, INSTANT
HOT WATER BOILERS AND
ADJACENT NITRO WORKSTATION
AS APPLICABLE. SEE BUILDING
FLOOR PENETRATION FOR FINAL
LOCATION.
DEDICATED RECEPTACLE
FOR ESPRESSO MACHINE
DEDICATED RECEPTACLE
FOR INSTANT HOT
WATER BOILER
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
WATER BOILER FOR
INSTANT HOT WATER
FONT (TYP. 1 OF 2)
2 2 IoTIoT
Scale: 3/4" = 1'-0"5 ESP ELECTRICAL
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-501
ELECTRICAL DETAILS
Scale: 3/4" = 1'-0"4 WRM - ELECTRICAL
Scale: 3/4" = 1'-0"2 STUB UPS - ESPRESSO BAR
Scale: 3/4" = 1'-0"5 STUB UPS - POS
Scale: 3/4" = 1'-0"3 POS - ELECTRICAL
GENERAL NOTES
A.ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS
(SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL
PLACEMENT.
B.PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED PER
CONDITIONS.
C.TRENCHING OUTLINE FOR GUIDELINE ONLY. GENERAL CONTRACTOR TO
COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE
ACTUAL LAYOUT.
KEYED NOTES
1.ALL CONDUITS TO STUB UP AND ROUTE THROUGH WALL TO ABOVE CEILING,
THEN PROCEED ABOVE CEILING(S) TO PANELBOARD AND/OR DATA RACK.
2.SAW CUT FLOOR WHERE REQUIRED.
3.COMMUNITY SEATING POWER. PROVIDE LEGRAND OMNIBOX OR EQUAL WITH
FLUSH FLOOR BOX COVER FOR WIREMOLDS. SEE ARCHITECTURAL DETAILS
FOR FINAL LOCATION.
Scale: 3/4" = 1'-0"8 SANITIZING WORKSTATION - ELECTRICAL
Scale: 3/4" = 1'-0"6 OVEN COMBI - ELECTRICAL
POWER AND DATA RECEPTACLE
AT 28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
·RECEPTACLE FOR OVEN
COMBI
·DATA PORT FOR OVEN
COMBI
POWER RECEPTACLE AT 28"
(711MM) TO TOP OF RECEPTACLE
A.F.F.
·RECEPTACLE FOR
UNDERCOUNTER REFRIGERATOR
1
EQ
EQ
4-
1
/
2
"
EQ EQ
2'-7"
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
2 3 3 3 3
5-
1
/
4
"
ESPRESSO BAR DIEWALL
1 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION
2 3/4" LAN CONDUIT TO MANAGER'S WORKSTATION
3 3/4" ISOLATED GROUND POWER CONDUIT
ESPRESSO BAR ELECTRICAL STUB-UP KEY
NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 3/4" POWER CONDUIT TO ELECTRICAL PANEL
2 1/2" PHONE TO MANAGER'S DESK
3 1/2" DATA CONDUIT TO MANAGER'S DESK
POS ELECTRICAL STUB-UP KEY
4 1/2" SECURITY TO MANAGER'S DESK
5 3/4" LAN CONDUIT TO POS/SAFE
6 3/4" POWER CONDUIT FOR PASTRY CASE
POS DIEWALL
EQ
EQ
4-
1
/
2
"
EQ EQ
2'-3"
10
-
1
/
2
"
1 2 5 634
NOTE :SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
RECEPTACLE FOR
SANITIZER AT 18"
(460MM) A.F.F.
BACK WALLQUAD RECEPTACLE
FOR GRINDER, SCALE
AND FUTURE USE
DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLES AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
Scale: 3/4" = 1'-0"7 BREW ELECTRICAL
DEDICATED
RECEPTACLE FOR
BREWER
DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
1'-3"3'-2-1/4"
6'-6"
3'-6-1/4"
42
2
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER EXPEDITOR,
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA J-BOX
4-DATA J-BOX
POWER AND DATA RECEPTACLES
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT.
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA J-BOX
SINGLE DATA J-BOX
POWER AND DATA RECEPTACLES
QUAD RECEPTACLE
FOR UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER RECEPTACLE
UNDERCOUNTER
REFRIGERATOR
DUPLEX CONVENIENCE
POWER RECEPTACLE
EDGE OF COUNTERTOP
NOTE:EQUIPMENT SHOWN AS
DASHED LINES IS TO BE
FURNISHED AND INSTALLED
BY OWNER UNLESS NOTED
OTHERWISE
DRIVE THRU WIRELESS HEADSET
BASE STATION
DRIVE THRU TIMER MONITOR
FUTURE HHOP CABLING TO HEADSET BASE
STATION FROM J-BOX AT CLG/WALL FOR
EXTERNAL EXTENDED COVERAGE ANTENNA
(FOIO)
DRIVE THRU DIGITAL
PRODUCTION MONITOR
4'
-
1
0
"
ELEVATION VIEW
DRIVE THRU TENDERING REGISTER
TRIPLE MONITOR MOUNT (GC INSTALLED)
SEE PLAN VIEW FOR MOUNTING LOCATION
POWER RECEPTACLES AT 28" (711MM) TO
TOP OF RECEPTACLE A.F.F.
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER, EXPEDITOR
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR TENDERING REGISTER
AND EXPEDITOR POS
4-DATA PORT FOR DT VIDEO, PED AND/OR
CONNECT DEVICES
POS BANK (TYP)
CASH DRAWERS
ELEVATION VIEW
DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO
DT VIDEO DATA BOX AT 28" (711MM) A.F.F.
DRIVE THRU TIMER CONTROL UNIT
POWER AND DATA RECEPTACLES AT 8'-2"
(2490MM) TO TOP OF RECEPTACLES A.F.F.
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA PORT FOR DT TIMER AND CONTROL
UNIT
SINGLE DATA PORT FOR DT AUDIO
(MIC & SPEAKER)
DRIVE THRU TIMER SIGNAL PROCESSOR (TSP)
36" W X 51" H (915MM W X 1295MM H) MIN. FIRE
RATED PLYWOOD BACKER BOARD. FASTEN TO
STRUCTURE. WALL FINISH TO CONCEAL.
DRIVE THRU EXPEDITOR POS
RECEIPT PRINTER
DT AUDIO CONDUIT FROM
DRIVE THRU ORDER POINT
AND DETECTOR LOOP
CONDUIT FROM DT
WINDOW TO DT TIMER
CONTROL DATA JUNCTION
BOXES AT 8'-2" (2490MM)
POWER RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
QUAD RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
SINGLE DOOR
REFRIGERATOR
DUPLEX CONVENIENCE
OUTLET AT 45" (1143MM) TO
TOP OF RECEPTACLE A.F.F.
5"
2'-5-1/2"
DIMENSIONS INDICATE CENTER
MOUNTING POINT FOR MONITOR BASE
*
Scale:NOT TO SCALE1DTP ELECTRICAL1
P1A-20
DTP RECEPTS. #1
REFER TO POWER PLAN
P1A-22
DTP RECEPTS. #2
P1A-26
DTP RECEPTS. #4
P1A-24
DTP RECEPTS. #3
UNDERCOUNTER
SAFE
18" X 3" (457MM X 76MM)
STUB-UP PENETRATION
AREA. SUPPLY POWER,
DATA AND PHONE
CONDUITS FOR POS
AND POWER CONDUIT
FOR PASTRY CASE.
SEE BUILDING FLOOR
PENETRATION PLAN
FOR FINAL LOCATION.
2
2
2
DEDICATED RECEPTACLE
FOR POS
2-DATA PORT FOR POS
AND FUTURE USE
POWER AND
DATA RECEPTACLES AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
EDGE OF COUNTERTOP
EDGE OF CABINET
SHELVING (BELOW)
DEDICATED RECEPTACLE
FOR UPS (POS AND PED)
2-DATA PORT FOR POS,
PED AND/OR CONNECT
DEVICES
POWER RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
QUAD RECEPTICLE
FOR FUTURE USE
2-DATA PORT FOR
FUTURE USE
POWER RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
2
UNDERCOUNTER
REFRIGERATOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
(2) DEDICATED
RECEPTACLE FOR
WARMING
2-DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
QUAD RECEPTACLE
FOR LABEL
PRINTER, FUTURE
USE AND/OR
CONNECT DEVICES
2-DATA PORT FOR
LABEL PRINTER
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
2
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-502
ELECTRICAL DETAILS
SURVEYOR
EQUIPMENT CONTROL PAC (ECP)
MOUNTED INSIDE HVAC SYSTEM
OUTDOOR
TEMP
COMMUNICATIONS POWER AND OUTPUTS ECONOMIZER THERMOSTAT
A B GND OUT2 OUT1 Y1 Y2 W1 W2 ON/OFF Y 1 2
A B GND 3 4ACCOMRAUXRCCK1CK2G
REMOTE AIRFLOW
SUCTION DISCHG
RETURNSUPPLY
REMOTE SENSOR IN CONDITIONED AREA
USE SINGLE SENSOR PER EXP/HVAC
SYSTEM PICK SENSOR TYPE BY LOCATION
ECP POWER &
HVAC CONTROL
WIRING
CONNECT 5
EQUIPMENT HEALTH
SENSORS AND 1
REMOTE SENSOR
SURVEYOR
RS-485
COMM THERMOSTAT
COMMUNICATION AND
POWER WIRING
THERMOSTAT TERMINAL -
THERMOSTATS GROUPED IN
MANAGERS WORKSTATION AREA
NOTES:
1. OUTDOOR TEMPERATURE SENSOR CONNECTED TO ONE ECP ONLY PER LOCATION.
FACE NORTH WHEN POSSIBLE.
2. SEE GENERAL NOTES 7 AND 8 FOR REMOTE SENSOR MOUNTING LOCATION DETAILS.
RS410 WALL MOUNT RS410 WALL MOUNT
(OPTIONAL)
RS420 DROP DOWN
1. SURVEYOR ENERGY MANAGEMENT SYSTEM HARDWARE IS SUPPLIED BY STARBUCKS.
2. DRAWING FOR GENERAL INFORMATION, DESIGN INTENT, AND COORDINATION ONLY.
3. LOCAL BUILDING CODES TAKE PRECEDENCE OVER THIS DOCUMENT.
4. NOT ALL WIRING IS SHOWN ON THIS DRAWING. FOR CLARITY, ONLY ONE EXAMPLE
OF EACH TYPE OF DEVICE IS SHOWN.
5. REFER TO THE SURVEYOR INSTALLATION INSTRUCTIONS FOR EACH COMPONENT
FOR DETAILED WIRING AND ADDITIONAL CRITICAL INFORMATION.
6. CAUTION! INSTALLATION REQUIRES THE REMOVAL OF SAFETY COVERS AND
EXPOSE THE INSTALLER TO HIGH VOLTAGE AND ELECTRICAL HAZARDS.
USE OF A LICENSED ELECTRICIAN IS REQUIRED. FOLLOW ALL APPROPRIATE
SAFETY PRECAUTIONS. ADDITIONAL SAFETY INFORMATION IS IN THE
SURVEYOR INSTALLATION MANUALS.
7. WALL MOUNTED REMOTE SENSOR IS MOUNTED ON WALL 4 TO 5 FT AFF.
AVOID AREAS WITH DIRECT AIRFLOW FROM SUPPLY REGISTERS.
8. USE A DROP DOWN SENSOR IF A WALL MOUNT SENSOR CANNOT BE INSTALLED DUE
TO SPACE CONSTRAINTS (SEE NOTE 7 FOR REQUIREMENTS). THE SENSOR CLIPS TO
THE T-BAR GRID AND ADJUSTED SO THE BOTTOM OF THE SENSOR IS 8 TO 9 FT AFF.
ALLOW 2 FT OF CLEARANCE FROM METRO SHELVING AND AVOID AREAS WITH DIRECT
AIRFLOW FROM SUPPLY REGISTERS.
9. FOR SURVEYOR EMS TECHNICAL SUPPORT AND SYSTEM COMMISSIONING,
CONTACT SURVEYOR TECHNICAL SUPPORT, (855) 647-7660, OPTION 1 OR EMAIL
INSTALLSUPPORT@VENSTER.COM. HOURS 6:00 AM TO 8:00 PM PACIFIC, MON-FRI.
SURVEYOR EMS COMPONENTS
VENSTAR PART SBUX ITEM #DESCRIPTION QUANTITY
LIGHTING CONTROL PANEL 1
DC500 11142580 DATA CONCENTRATOR 1
OTS400 011029487 OUTDOOR TEMPERATURE SENSOR 1
ECP400 011029489 EQUIPMENT CONTROL PAC 1 PER HVAC
CT414 011029490 COMMUNICATING THERMOSTAT 1 PER HVAC
SP400 011029491 SENSOR PAC 1 PER HVAC
RS410 011029492 WALL MOUNT REMOTE SENSOR 1 PER FOH HVAC
RS420 011050767 NARROW DROP DOWN SENSOR 1 PER BOH HVAC
AS NEEDED
LCP401 011029483
MD400 011029497 ADDITIONAL MOTION DETECTOR
OPTIONAL
GENERAL NOTES
PHOTOCELL
SURVEYOR
LIGHTING CONTROL PANEL
THERMOSTATECP
REMOTE
SENSOR
THERMOSTATECP
REMOTE
SENSOR
MULTIPLE ECP'S MAY BE
COMBINED ON A SINGLE
DC PORT WHEN MORE
THAN 3 ECP'S ARE USED.
SECOND HVAC SYSTEM.
REPEAT AS NECESSARY.
DROP DOWN STYLE
SENSOR SHOWN. SEE
GENERAL NOTES 7 AND 8
FOR SENSOR MOUNTING
LOCATION.
FIRST HVAC SYSTEM.
WALL MOUNT STYLE
SENSOR SHOWN. SEE
GENERAL NOTES 7 AND 8
FOR SENSOR MOUNTING
LOCATION.
CONCENTRATOR
ETHERNET TO
NETWORK
SURVEYOR
SURVEYOR
Communicating Lighting Control
SALES LIGHTS
SIGN LIGHTS
SITE LIGHTS
WORK LIGHTS
OVERRIDE
Disconnect Power
Before Opening
HIGH VOLTAGE
WARNING:
SURVEYOR
SURVEYOR
SURVEYOR
[minutes]
120
0
[minutes]
120
0
[minutes]
120
0
[minutes]
120
0
WORK LIGHTS
OVERRIDE
WORK LIGHTS
OVERRIDE
WORK LIGHTS
OVERRIDE
WORK LIGHTS
MOTION SENSORS
1 OR MORE AS
NECESSARY
DATA CONCENTRATOR
DATA
CONCENTRATOR
POWER SUPPLY
SURVEYOR
CAT-5 ETHERNET CABLE CONNECTED TO NETWORK ROUTER.
SURVEYOR RS-485 COMM
CONNECT TO ALL DEVICES
HOME-RUN WHEN
POSSIBLE
CONNECT ETHERNET CABLE TO LAN
PORT #37 ON ROUTER IN DATA RACK
LAN
1 3 5 7
2 4 6 8
PHOTOCELL MOUNTED
OUTDOORS, TYPICALLY ON
ONE HVAC
SURVEYOR
RS-485 COMM
LIGHTING CONTROL BOARD
LIGHT
SENSOR
PUSH
BUTTON
SECURITY
ALARM
MOTION
SENSOR RS485
LIGHTING CONTROL PANEL BUILT IN CONTACTORS
CONNECT TO LIGHTING CIRCUITS PER ZONES ON ELECTRICAL PLANS
C-1
INTERIOR
WORK
C-2
INTERIOR
SALES
MOTION
DETECTORS
1 OR MORE
AS NEEDED
(TYPICALLY 2
REQUIRED)
C-3
EXTERIOR
SIGN
C-3A
EXTERIOR
SIGN
C-4
PARKING
SITE
C-4A
PARKING
SITE
4 Venstar EMS - Full Lighting Control - HVAC Controls
1 Venstar EMS - Full Lighting Control - Basic Low Voltage Wire Runs2Venstar EMS - Full Lighting Control - Data Concentrator3Venstar EMS - Full Lighting Control
INTERIOR BOH
VENSTAR LCP
EF-1
FAN SPEED CONTROL
SWITCH IF NEEDED.
RELAY REQUIRED (R8222 OR SIMILAR).
MOTOR RATED RELAY CONTACTOR.
A 2
BOH
LIGHTING
CKT N
EF-1
CKT
N
1
2
1
2
DURING OCCUPIED MODE THE EXHAUST FAN MOTOR
DAMPER SHALL OPEN AND FAN SHALL START.
DURING UNOCCUPIED MODE THE EXHAUST FAN
MOTOR DAMPER SHALL BE CLOSED AND FAN SHALL BE OFF.
N.T.S.5 EXHAUST FAN CONTROL WIRING DIAGRAM
N.T.S.
N.T.S.N.T.S.N.T.S.
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-503
ELECTRICAL EMS
DETAILS
EXISTING PANELBOARD NOTES
1.THESE PANELBOARD SCHEDULES WERE CREATED USING THE SCHEDULES INSIDE
THE EXISTING PANELBOARDS, SURVEY NOTES, SURVEY PHOTOS AND/OR THE
ORIGINAL CONSTRUCTION DRAWINGS. ACTUAL CIRCUIT CONNECTIONS AND LOADS
MAY VARY FROM THIS SCHEDULE. THE CONTRACTOR SHALL VERIFY THE EXISTING
CIRCUITS IDENTIFYING THE ACTUAL LOADS SERVED. THE CONTRACTOR SHALL
PROVIDE NEW PANELBOARD SCHEDULES AND PLACE INSIDE EACH PANELBOARD.
COPIES OF THESE SCHEDULES SHALL BE PROVIDED TO OWNER.
2.THE CONTRACTOR IS CAUTIONED THAT THE EXISTING PANEL SCHEDULES MAY NOT
BE REPRESENTATIVE OF THE ACTUAL LOADS SERVED BY EACH CIRCUIT. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EACH EXISTING CIRCUIT,
IDENTIFYING ACTUAL LOAD SERVED AND MEASURE ACTUAL PANEL LOAD. MAKE
ADJUSTMENTS REQUIRED TO ACCOMMODATE NEW BREAKERS WHERE REQUIRED.
RE-BALANCE ALL PANEL LOADS. PROVIDE NEW CIRCUIT DIRECTORIES REFLECTING
ALL NEW AND EXISTING LOADS. ANY ADJUSTMENTS SHALL BE COORDINATED WITH
OWNER'S REPRESENTATIVE.
GROUND FAULT PROTECTION NOTES
·PROVIDE GFCI PROTECTION AS REQUIRED BY NEC 210.8.
·CIRCUITS REQUIRING GFCI PROTECTION IDENTIFIED WITH 'G' ON PANEL SCHEDULES
(THIS SHEET).
·ABOVE-COUNTER RECEPTACLES THAT ARE READILY ACCESSIBLE AND WITHIN REACH
OF PARTNERS SHALL BE GFCI TYPE.
·BELOW-COUNTER RECEPTACLES, OR RECEPTACLES THAT ARE DIFFICULT TO REACH
OR REQUIRE MOVING EQUIPMENT TO RESET, AND ARE NOT READILY ACCESSIBLE
SHALL BE PROTECTED BY GFI CIRCUIT BREAKERS.
·WHERE THE AVAILABLE SHORT CIRCUIT CURRENT EXCEEDS 22,000 AMPS AT THE
PANELBOARD, CONTACT CIRCUIT BREAKER MANUFACTURER AND PROVIDE GFCI
TYPE CIRCUIT BREAKER THAT SERIES RATES WITH PANEL OVER CURRENT
PROTECTION IF AVAILABLE.
·WHERE THE AVAILABLE SHORT CIRCUIT CURRENT EXCEEDS 22,000 AMPS AT THE
PANELBOARD, AND GFCI BREAKERS ARE NOT AVAILABLE, PROVIDE DEAD-FRONT
GFCIS (IN A READILY ACCESSIBLE LOCATION) TO SERVE RECEPTACLES THAT ARE
NOT READILY ACCESSIBLE.
EXISTING SINGLE LINE DIAGRAM
SCALE: N.T.S.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO
VERIFY VOLTAGE DROP OF ALL FEEDER/BRANCH
CIRCUIT COMBINATIONS BASED ON ACTUAL
CONDUCTOR LENGTHS PER ROUTING IN FIELD
AND UPSIZE CONDUCTORS AS REQUIRED SUCH
THAT VOLTAGE DROP DOES NOT EXCEED 5% FOR
ANY FEEDER/BRANCH CIRCUIT COMBINATION.
EXISTING ELECTRICAL DISTRIBUTION IS EXISTING TO
REMAIN. NO WORK AS PART OF THIS PROJECT.
EXISTING ELECTRICAL DISTRIBUTION AND PANEL
CONFIGURATIONS IS SHOWN PER SHELL
ELECTRICAL DRAWINGS, DATED 03/25/24 FOR
INFORMATION ONLY. FIELD VERIFY ALL CONDITIONS
PRIOR TO START OF WORK.
PER LANDLORD WORK LETTER, ALL BRANCH
BREAKERS WILL BE EXISTING/PROVIDED WITH
PANELS IN THE SHELL PORTION OF THE PROJECT,
AS SHOWN ON TENANT CONTRUCTION PLANS
(THIS SET)
ON GRADE
EXISTING UTILITY
XFMR TO REMAIN.
EXISTING UTILITY
PRIMARY TO
REMAIN.
PANEL "A"PANEL "B"
EXISTING 600A
PANEL 'A' TO REMAIN.
EXISTING 225A
FEEDERS TO REMAIN.
EXISTING 225A
PANEL 'B' TO REMAIN.
EXISTING 600A
DISCONNECT
SWITCH TO REMAIN.
EXISTING
GROUNDING
SYSTEM TO REMAIN.
MEXISTING UTILITY
METER TO REMAIN.
EXISTING FEEDERS
TO REMAIN.
EXISTING CT
CABINET TO REMAIN.
EXISTING UTILITY
SECONDARY TO
REMAIN.
EXISTING 600A
FEEDERS TO REMAIN.
STARBUCKSEXTERIORADJACENT TENANT ELEC ROOM
C1
LIGHTING CONTROL DIAGRAM
EXHAUST FAN CONTROL NOTES :
WHEN THE STORE IS OPEN, THE
EXHAUST FAN MOTOR DAMPER
SHALL OPEN AND FAN SHALL RUN.
WHEN THE STORE IS CLOSED, THE
EXHAUST FAN MOTOR DAMPER
SHALL BE CLOSED AND FAN SHALL
BE OFF.
CONTROL NOTES :
1.ON 1 HOUR BEFORE STORE OPEN.
2.OFF 1 HOUR AFTER STORE CLOSE.
LIGHTING CONTROL NOTES:
LIGHTING CONTROL BY VENSTAR EMS SYSTEM.
SEE DETAILS ON E-5002 FOR VENSTAR EMS SYSTEM CONNECTION DETAILS.
EXHAUST FAN RELAY
RECIRCULATION PUMP
SPARE
c
C2
CAFE ACCENT LIGHTING
SHOW WINDOW RECEPTS
C3
MONUMENT SIGNAGE
SPARE
SPARE
C4
EXTERIOR SITE LIGHTING
C5
C6
DT MENU BOARDS
DT DIRECTIONAL SIGNAGE
BLDG MOUNTED SIGNAGE
BUILDING FACADE LIGHTING
FIELD VERIFY NUMBER OF
CONTACTS REQUIRED
FOR EXISTING EXTERIOR
LIGHTING. (1) CONTACT
PER CIRCUIT REQUIRED.
PC
VENSTAR LIGHTING CONTROL PANEL
CONTROL NOTES :
1.ON 1 HOUR BEFORE STORE OPEN.
2.OFF 1 HOUR AFTER STORE CLOSE.
CONTROL NOTES :
1.ON AT STORE OPEN, OFF AT DAWN.
2.ON AT DUSK, OFF AT STORE CLOSE.
CONTROL NOTES :
1.ON AT STORE OPEN, OFF AT DAWN.
2.ON AT DUSK, OFF AT STORE CLOSE.
CONTROL NOTES :
1.ON AT STORE OPEN, OFF AT DAWN.
2.ON AT DUSK, OFF AT STORE CLOSE.
CONTROL NOTES :
1.ON AT STORE OPEN.
2.OFF AT STORE CLOSE.
A-11
SPARE
a
b
ENGINE LIGHTING
CAFE LIGHTING
d
e
CAFE/ENGINE TAPE LIGHT
f
RESTROOM VESTIBULE
ENGINE PENDANT
g
h
WORKROOM
CAFE SCONCE LIGHTING
EXTERIOR WALL LIGHTING
EXTERIOR POLE
SPARE
SPARE
SPARE
SPARE
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
LJG
LJG
WHS
Revision Schedule
Rev Date By Description
E-601
PANELBOARD
SCHEDULES
M-001
GENERAL MECHANICAL NOTES
GENERAL NOTES
SCOPE
SITE EXAMINATION
PENETRATIONS
STANDARDS
CODES
PERMITS AND FEES
WARRANTY
TESTING, ADJUSTING, BALANCING
HVAC EQUIPMENT AND MATERIALS
AIR HANDLING UNITS
FILTERS
EXHAUST FANS
AIR CURTAINS
NATURAL GAS PIPING
SYSTEM.
BRACING AND ANCHORING
DUCTWORK AND ACCESSORIES
SHEET METAL DUCTWORK
DUCT SEALANT
SUPPORTS
DAMPERS
GRILLES, REGISTERS, AND DIFFUSERS
THERMAL INSULATION
ACOUSTICAL DUCT LINER
FLEXIBLE DUCTWORK
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITIES HAVING JURISDICTION
APPROX APPROXIMATE
BLDG BUILDING
CO2 CARBON DIOXIDE
CD CEILING DIFFUSER
CLG CEILING
CONST CONSTRUCTION
CXA COMMISSIONING AGENT
DEG DEGREES
DM STARBUCKS DESIGN MANAGER
DN DOWN
DTL DETAIL
DWG(S)DRAWING(S)
EA EACH
EC ELECTRICAL CONTRACTOR
ECP EQUIPMENT CONTROL PAC
EG EXHAUST GRILLE
ELEC ELECTRICAL
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EXIST EXISTING
EXT EXTERIOR
F&I FURNISH & INSTALL
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER,
INSTALLED BY OWNER
FLR FLOOR
FT FOOT/FEET
G GAS PIPING
GC GENERAL CONTRACTOR
HR HOUR
HVAC HEATING, VENTILATION, AIR CONDITIONING
I.D.INSIDE DIAMETER
IAQ INDOOR AIR QUALITY
LCP LIGHTING CONTROL PANEL
LL LANDLORD
LV LOW VOLTAGE
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL AND PLUMBING
MFG MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
O.D.OUTSIDE DIMENSION
OSA OUTSIDE AIR
REF REFERENCE
REQ'D REQUIRED
REV REVISION
RT ROOFTOP
SF SQUARE FEET
SHT SHEET
SPECS SPECIFICATION(S)
SST STAINLESS STEEL
TEMP TEMPORARY
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UC UNDER COUNTER
WH WATER HEATER
WSHP WATER SOURCE HEAT PUMP
ABBREVIATIONS
ENERGY MANAGEMENT SYSTEM (EMS)
A
12"Ø
400 CFM
MECHANICAL SYMBOL LEGEND
BD
D
S
12 X 8
12 X 8
TYPICAL SUPPLY DUCT UP/DN
TURNING VANES
EQUIPMENT DESIGNATIONXX-1
AIRFLOW ARROW
DUCT HEATER
MANUAL VOLUME
DAMPER
BACK DRAFT DAMPER
SMOKE DETECTOR
UNDERCUT DOOR
CONNECT TO EXISTING
FLEXIBLE DUCT CONNECTION
NECK SIZE
DESIGN CFM (WHERE APPLICABLE)
DIFFUSER TYPE (REFER SCHEDULE)
CEILING RETURN GRILLE
COMBINATION
SMOKE AND FIRE
DAMPER
SPIN-IN TAKE-OFF
AND VOLUME
DAMPER
INDICATES UNLINED 12" X 8" O.D. SHEETMETAL
1ST FIGURE = SIDE SHOWN
2ND FIGURE = SIDE NOT SHOWN
INDICATED 14" X 10" (355mm X 255mm) O.D.
SHEETMETAL W/ 1" (25mm) SOUNDLINER
(U.N.O), 12" X 8" (305mm X 205mm I.D. NET
FLEXIBLE DUCT
CEILING DIFFUSER (FLOW ARROWS
SHOWN ONLY IF AIR FLOW NOT
SYMMETRICAL)
THERMOSTAT
REMOTE THERMOSTAT
SENSOR
CONTROLS AND OPERATION NOTES
THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL THE
FOLLOWING COMPONENTS:
CONTROL WIRING
THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL
WIRING IN CONDUIT NECESSARY FOR THE COMPLETE AND PROPER
OPERATING TEMPERATURE CONTROL SYSTEM INCLUDING ALL MODES
OF OPERATION AND INTERLOCK.
EXHAUST FANS
RESTROOM EXHAUST FAN(S) TO BE OPERATED IN CONJUNCTION WITH
STORE HOURS UNLESS OTHERWISE NOTED OR APPROVED OR AS
REQUIRED BY JURISDICTION (COORDINATE WITH ELECTRICAL).
THERMOSTAT
THERMOSTAT SETUP INSTRUCTIONS
PROVIDE THE FOLLOWING SETUP AND PROGRAMMING:
1.CONFIGURE AS FOLLOWS:
A.DEGREES "F" DISPLAY
B.12 HOUR CLOCK
C.CONTINUOUS FAN OPERATION IN OCCUPIED
MODE
D.DISABLE KEYBOARD PROGRAMMING
2.SET TIME AND DATE.
3.SET TO DISPLAY CURRENT TEMPERATURE.
4.SET OCCUPIED START TIME AT 30 MIN. BEFORE OPENING.
SET UNOCCUPIED START TIME AT 30 MIN. AFTER CLOSING.
VERIFY HOURS WITH STORE MANAGER OR
CONSTRUCTION MANAGER.
5.SET POINTS SHALL BE AS FOLLOWS OR AS APPROPRIATE
FOR CLIMATE:
A.OCCUPIED (5° F DEADBAND) (3° C DEADBAND)
I.HEATING:70° F (21° C)
II.COOLING:75° F (24° C)
B.UNOCCUPIED
I.HEATING:60° F (15° C)
II.COOLING:78° F (25° C)
6.SET TWO (2) HOUR OCCUPIED OVERRIDE FUNCTION TO
PROVIDE THE FOLLOWING SET POINT OVERRIDES:
A.HEATING:+2° F (1° C)
B COOLING:-2° F (1° C)
DEMAND CONTROL VENTILATION (DCV)
THE C02 SENSOR SHALL MODULATE THE AIR HANDLING UNIT OUTSIDE
AIR DAMPER TO MAINTAIN 1000 PPM C02 OR LESS
OCCUPIED MODE:
1.FAN SHALL RUN CONTINUOUSLY WHILE BRINGING IN
MINIMUM DCV OUTSIDE AIR AS INDICATED IN SCHEDULE.
2.IF C02 SENSOR SET POINT IS BELOW THE SETPOINT, THE
AIR DAMPER SHALL BE OPEN TO THE CALCULATED DCV
MINIMUM OUTSIDE AIR.
3.IF C02 SENSOR SETPOINT IS EXCEEDED, OUTSIDE AIR
DAMPER SHALL MODULATE TO MAINTAIN 1000 PPM NOT TO
EXCEED THE CALCULATED DESIGN MINIMUM OUTSIDE AIR.
4.UPON C02 PPM FALLING BELOW THE SETPOINT, THE AIR
DAMPER SHALL RETURN TO DCV MINIMUM OUTSIDE AIR.
5.THE ECONOMIZER SHALL HAVE PRIORITY OVER THE DCV
CONTROLS, OUTSIDE AIR MAY EXCEED DCV MINIMUM AND
DESIGN MINIMUM WHEN AIR CONDITIONS ARE
APPROPRIATE TO DO SO.
UNOCCUPIED MODE:
1.FAN SHALL CYCLE WITH HEATING AND OUTSIDE AIR
DAMPER CLOSED. OUTSIDE DAMPER SHALL NOT BE
CYCLED WITH C02 PPM SETPOINT.
IAQ MANAGEMENT PLAN
DURING CONSTRUCTION, CONTRACTOR SHALL COMPLY WITH CHAPTER 3
OF SMACNA’S IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER
CONSTRUCTION. CONTRACTOR SHALL PERFORM AND SUBMIT ALL
INFORMATION AS REQUIRED. IF HVAC SYSTEM IS TO BE USED DURING
CONSTRUCTION, INSTALL MERV 13 FILTERS AT EACH RETURN AIR GRILL
AND COMPLY WITH SMACNA’S GUIDELINES REFERENCED BELOW.
INDEPENDENT AIR BALANCE CONTRACTOR OR QUALIFIED MECHANICAL
CONTRACTOR SHALL BE QUALIFIED TO TAB WORK BY NEBB OR AABC
STANDARDS. BALANCER SHALL ACCURATELY BALANCE THE SUPPLY,
RETURN AND OUTSIDE AIR, EXHAUST FAN(S), HYDRONIC (WHERE
APPLICABLE) AND EXHAUST FAN(S) SYSTEMS TO PROVIDE AIR AND
WATER QUANTITIES WITHIN 10% PLUS OR MINUS OF THE VALUES
INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS. OPERATE
AUTOMATIC CONTROLS SYSTEMS AND VERIFY SETPOINTS FOR
THERMOSTATS, C02 SENSORS, DCV, EMS AND ECONOMIZER/OUTSIDE
AIR DAMPER. SEE CONTROLS AND OPERATION NOTES AND HVAC
SCHEDULES AND NOTES FOR DETAILS. IF DEFICIENCIES OR SITE
CONDITIONS PREVENT COMPLETE AND PROPER BALANCING, DO NOT
COMPLETE WORK AND SUBMIT A REQUEST FOR INFORMATION TO GET
COMPLETE INFORMATION PRIOR TO COMPLETING WORK. SUBMIT THREE
(3) COPIES OF THE BALANCE REPORT TO THE ENGINEER, CONSTRUCTION
MANAGER AND COMMISSIONING AGENT FOR APPROVAL. THE BALANCE
REPORT SHALL INCLUDE NEBB OR AABC CREDENTIALS,
EQUIPMENT/INSTRUMENT LIST WITH THE MOST RECENT CALIBRATION
DATE AND BALANCE REPORTS FOR ALL HVAC AND EXHAUST SYSTEMS.
INCLUDE A COPY OF THE BALANCE REPORT AS APPROVED BY THE
ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT. ALSO
PROVIDE A TAB REPORT TO THE INSPECTOR AT THE FINAL INSPECTION.
AIR HANDLING UNITS SHALL BE AS SPECIFIED IN THE MECHANICAL
SCHEDULE AND SHALL BE FURNISHED AND INSTALLED PER THE LEASE
AGREEMENT. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR
COORDINATING DELIVERY, PROVIDING COMPLETE INSTALLATION
INCLUDING CURBS, PIPING, VIBRATION ISOLATION, AND NECESSARY
ACCESSORIES, AND PROVIDING WARRANTY.
IF OPERATING HVAC DURING CONSTRUCTION, PROVIDE THREE (3) SETS
OF 2" (51MM) MERV13 PLEATED DISPOSABLE FILTERS (OR HIGHER
RATING IF REQUIRED BY LEED). USE ONE SET UNTIL COMPLETION OF
CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION
(PRIOR TO TAB) AND DELIVER ONE SET OF MERV13 FILTERS TO
STARBUCKS LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING
UNIT.
EXHAUST FANS SHALL BE AS SPECIFIED AND PROVIDED PER THE LEASE
AGREEMENT. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR
COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS
AND INTAKES, PROVIDING COMPLETE INSTALLATION INCLUDING CURBS,
BACKDRAFT DAMPER, DUCTWORK FROM RESTROOM GRILLE TO UNIT,
NECESSARY ACCESSORIES AND PROVIDING WARRANTY.
AIR CURTAINS, WHEN REQUIRED, SHALL BE FURNISHED BY OWNER WITH
WINDOW UNIT FROM READY-ACCESS AND INSTALLED BY THE GENERAL
CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR FOR
LOCATION OF POWER CONNECTION. ALL OTHER AIR CURTAINS SHALL BE
FURNISHED BY THE CONTRACTOR.
PROVIDE NATURAL GAS PIPING FROM GAS COMPANY METER TO EACH
PIECE OF EQUIPMENT OR APPLIANCES IN ACCORDANCE WITH CODE AND
THE PROJECT MANUAL. PRESSURE REGULATORS FOR MEDIUM
PRESSURE SYSTEMS SHALL BE VENTED TO THE OUTDOORS. PROVIDE
PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING
ALL MECHANICAL EQUIPMENT, FIXED OR FLEXIBLY MOUNTED, SHALL BE
BRACED OR ANCHORED TO COMPLY WITH LOCAL CODES.
SEE SPECIFICATIONS FOR SHEET METAL DUCT REQUIREMENTS. ALL
EXPOSED DUCTWORK TO BE SPIRAL ROUND, OR RECTANGULAR
LOCK-SEAM TYPE, AS SHOWN ON HVAC PLAN SHEET. ASSEMBLE AND
INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY
PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND NOISELESS (NO
OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH
INDICATED SERVICE. FURNISH AND INSTALL ALL REQUIRED DAMPERS,
TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER
ACCESSORIES NECESSARY FOR COMPLETE OPERATING SYSTEM. NO
VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED
EXCEPT BY PERMISSION FROM THE ENGINEER.
SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS PER SPECIFICATIONS.
COVER ALL FIELD JOINTS, JOINTS AROUND SPIN-IN FITTINGS, AND
FASTENING SCREWS WITH MASTIC.
PROVIDE FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND ANGLES FOR
SUPPORT OF DUCTWORK. SUPPORTS MUST COMPLY WITH LOCAL
REGULATIONS AND CODE.
PROVIDE VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS
AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST
DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL
LISTED FIRE OR FIRE/SMOKE DAMPERS WHERE REQUIRED AND IN
ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVENIENTLY
LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING
THE DAMPERS. PROVIDE MOTORIZED DAMPERS AT ALL INTAKE & EXHAUST
BUILDING OPENINGS. COORDINATE WITH OTHER TRADES FOR ACCESS
PANELS, POWER AND FIRE ALARM INTERFACES. SEE PROJECT MANUAL.
WHERE VOLUME DAMPERS ARE LOCATED IN IN-ACCESSIBLE AREAS SUCH
AS ABOVE DRYWALL CEILINGS, REMOTE DAMPER OPERATORS SHALL BE
PROVIDED SO THAT DAMPERS CAN BE ADJUSTED THROUGH THE FACE OF
THE DIFFUSERS/GRILLES (BOWDEN REMOTE CABLE CONTROLLERS BY
YOUNG REGULATOR, OR EQUAL).
GRILLES, REGISTERS, AND DIFFUSERS SHALL BE AS SPECIFIED AND SHALL
BE MECHANICAL CONTRACTOR SUPPLIED, UNLESS OTHERWISE NOTED.
DIFFUSERS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND
SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL
MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER
INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS PROJECT.
PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR
BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY
CODE REQUIREMENTS OR ASHRAE 90.1-2004, WHICHEVER IS MORE
STRINGENT. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS,
AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO
NOT EXTERNALLY INSULATE EXPOSED DUCTWORK AND PORTIONS OF
DUCTWORK THAT ARE INTERNALLY LINED WITH CODE REQUIRED
THICKNESS. INTERNALLY INSULATE EXPOSED SUPPLY DUCTWORK IF
POSSIBILITY OF CONDENSATION. INTERNALLY INSULATE EXTERIOR
DUCTWORK PER CODE. R-8 INSULATION MINIMUM.
UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" (25MM)
ACOUSTICAL DUCT LINER IN SUPPLY AND RETURN DUCTWORK WITHIN
10'-0" (305CM) OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS.
INCREASE DUCT SIZE INDICATED ON PLANS AS NEEDED TO ACCOMMODATE
LINER. LINER TO BE PROVIDED AND FASTENED TO DUCT WITH
MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMACNA AND
PROJECT MANUAL.
FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS SHOWN IN PLAN AND
NOT ABOVE HARD LID CEILINGS. FLEXIBLE DUCTWORK SHALL NOT EXCEED
5’-0" (152CM) IN LENGTH AND TWO 45° ELBOWS. IT SHALL BE PULLED TAUT
AND APPROPRIATELY FASTENED TO RIGID BRANCH DUCT & DIFFUSER.
BENDS SHALL BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND.
SUPPORT BANDS SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT.
FLEXIBLE DUCTWORK SHALL MEET REQUIREMENTS.
THE MECHANICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT
ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP
FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE
BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS
AND WORKMANSHIP.
THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL
PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE
MECHANICAL WORK.
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF
CONFLICT BETWEEN THE DRAWINGS AND PROJECT MANUAL AND THE
CODES AND ORDINANCES, USE WHICHEVER IS MORE STRINGENT. THE
MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A
MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. THE
BUILDING SHALL MEET OR EXCEED THE PROVISIONS FOR MECHANICAL
VENTILATION OF CAL GREEN CODE.
EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE
PROVISIONS OF CSA, ULC, ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA,
ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY.
THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL
AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED
AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE
PROPER INSTALLATION OF THE MECHANICAL WORK.
THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO
PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM.
THE MECHANICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL,
AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK.
WHERE PIPES AND DUCTS PENETRATE WALL, SEAL OPENINGS TO
PREVENT AIR TRANSFER BETWEEN SPACES. USE FIRE RATED SEALANTS
ON ALL FIRE SEPARATION PENETRATIONS, INCLUDING FLOORS. SEAL
AROUND ALL PIPES AND DUCTS PENETRATING FIRE SEPARATIONS WITH
NON-COMBUSTIBLE PACKING RETAINED BY METAL COLLARS. THE
ASSEMBLY SHALL BE APPROVED BY STATE FIRE MARSHALL.
1.MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE
GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING
WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO
REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF
WORK.
2.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT
OR ARRANGEMENT OF SYSTEM(S). FURNISH & INSTALL ALL
COMPONENTS NEEDED WHETHER INDICATED OR NOT TO
PROVIDE A COMPLETE AND OPERATING SYSTEM.
3.CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING
CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY
STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES
PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE
TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED
OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM ACTUAL
BUILDING DIMENSIONS.
4.THE MECHANICAL CONTRACTOR SHALL COORDINATE HVAC
WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS
AND PROJECT MANUAL SHALL TAKE PRECEDENCE OVER ALL
OTHER DRAWINGS. SEE ARCHITECTURAL DRAWINGS AND
PROJECT MANUAL FOR DIMENSIONED DIFFUSER LOCATIONS AND
MOUNTING HEIGHTS WHERE EXPOSED.
5.NEW DUCTWORK AND EQUIPMENT SHALL NOT BE INSTALLED
WHERE IT OBSTRUCTS ANY EXISTING OR NEW AREAS THAT
REQUIRE ACCESS.
WHEN AN ENERGY MANAGEMENT SYSTEM IS TO BE INSTALLED, THE
CONTRACTOR SHALL COORDINATE WITH THE EMS VENDOR FOR A
COMPLETE CONTROL SYSTEM. FURNISH AND INSTALL ALL LOW VOLTAGE
WIRING THROUGH EC PROVIDED CONDUITS (COORDINATE WITH
ELECTRICAL).
EMS VENDOR SHALL PROVIDE ONE THERMOSTAT AND REMOTE SENSOR
PER HVAC UNIT. LOCATE AND MOUNT THERMOSTAT(S) AND SENSOR(s) PER
THE DRAWINGS. PROVIDE THERMOSTAT IDENTIFICATION LABELS PER
SPECIFICATION REQUIREMENTS.
VENDOR SHALL PROGRAM AND COMMISSION CONTROL SYSTEM. EMS
THERMOSTATS SHALL BE PROGRAMMED TO MEET LOCAL CODE
REQUIREMENTS.
TYPICAL RETURN DUCT UP/DN
TYPICAL EXHAUST DUCT UP/DN
CEILING EXHAUST GRILLE
TYPICAL SUPPLY DUCT
UP THRU ROOF
TYPICAL RETURN DUCT
UP THRU ROOF
TYPICAL EXHAUST DUCT
UP THRU ROOF
SUPPLY GRILLE
RETURN GRILLE
PERMANENT THERMOSTAT(S) AND REMOTE SENSOR(S) SHALL BE
FURNISHED AND INSTALLED. ONE THERMOSTAT AND SENSOR IS
PROVIDED FOR EACH AIR HANDLING UNIT. MOUNT THERMOSTAT(S)
AND SENSOR(S) IN LOCATION & HEIGHT AS INDICATED ON DRAWINGS.
MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT
IDENTIFICATION LABELS PER SPECIFICATION REQUIREMENTS. REFER
TO THERMOSTAT SETUP INSTRUCTIONS BELOW FOR ADDITIONAL
REQUIREMENTS.
REMOTE TEST
STATION
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
M-001
MECHANICAL NOTES
M-101GENERAL NOTES OVEN VENTLESS CERTIFICATION NOTE:
STARBUCKS DOES NOT COOK FOOD. ALL FOOD IS SHIPPED TO THE STORES PRE-COOKED AND PACKAGED. THE STORES ONLY
USE THE WARMING OVENS TO WARM UP THE FOOD. THE WARMING OVENS ARE VENTLESS CERTIFIED AND UL LISTED, UL 710B,
REFER TO CUT SHEET. IT SHOULD BE SPECIFICALLY NOTED, PER CUTSHEET VENTLESS REQUIREMENTS, THAT NO FOODS
CLASSIFIED AS "FATTY RAW PROTEINS" ARE COOKED IN THE STORE.
KEYNOTES
1.CONNECT TO EXISTING SUPPLY ROOFTOP DUCT DROP BY LANDLORD AND EXTEND THRU
SPACE AS SHOWN.
2.CONNECT TO EXISTING RETURN ROOFTOP DUCT DROP BY LANDLORD AND EXTEND THRU
SPACE AS SHOWN.
3.CONNECT TO EXISTING EXHAUST ROOFTOP DUCT DROP BY LANDLORD AND EXTEND THRU
SPACE AS SHOWN.
4.1" UNDERCUT ON DOOR.
5.WALL MOUNTED THERMOSTAT(S) & REMOTE TEST STATIONS. REFER TO MECHANICAL
NOTES, MECHANICAL SCHEDULES, AND MECHANICAL SPECIFICATIONS FOR THERMOSTAT
REQUIREMENTS, SOURCING, AND RESPONSIBILITY. MULTIPLE THERMOSTATS SHALL BE
STACKED IN A VERTICAL CONFIGURATION WITH A MINIMUM 8" CLEARANCE BELOW EACH
THERMOSTAT. COORDINATE FINAL LOCATION OF REMOTE TEST STATION WITH FIRE
MARSHALL PRIOR TO ROUGH-IN.
6.REMOTE TEMPERATURE SENSOR AT 60" A.F.F. AND CO2 SENSOR AT 48" A.F.F., FURNISHED
AND INSTALLED BY HVAC CONTRACTOR. FIELD VERIFY ALL REQUIREMENTS.
7.NOT USED.
8.DRIVE-THRU/WALK-UP AIR CURTAIN.
9.PROVIDE DOOR SWITCH FOR AIR CURTAIN, COORDINATE WITH ELECTRICAL. COORDINATE
WITH MANUFACTURER SPECIFICATIONS AND MECHANICAL INSTALLER PRIOR TO ROUGH-IN.
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.
RESTROOM 1
RESTROOM 2
M-101
MECHANICAL PLAN
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
M-102 KEYNOTES
1.EXISTING ROOFTOP PACKAGED HVAC UNIT BY LANDLORD TO REMAIN.
2.EXISTING ROOFTOP EXHAUST FAN PROVIDED BY LANDLORD.
3.MAINTAIN MINIMUM 10FT BETWEEN EXHAUST FAN/SANITARY VENT
DISCHARGE LOCATION AND ANY OUTSIDE AIR INTAKES.
4.EXISTING SANITARY VENT THROUGH ROOF.
5.ROOF MOUNTED REMOTE CONDENSING UNIT FOR ICE MACHINE. EXTEND
REFRIGERANT PIPING TO ICE MACHINE, SEAL ROOF OPENINGS
WEATHER-TIGHT.
M-102
MECHANICAL ROOFTOP
PLAN
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
M-601
1 LAY IN DIFFUSER
N.T.S.
2 DUCT HANGING DETAIL
N.T.S.
1.CLASSIFICATION OF "FOOD AND BEVERAGE SERVICE: CAFETERIA, FAST FOOD" RESULTS IN AN ESTIMATED QUANTITY OF PEOPLE ON A SQUARE FOOTAGE BASIS THAT IS UNREALISTIC WITH REGARD TO THE ACTUAL USE OF THE SPACE. THE CALCULATED
NUMBER OF PEOPLE HAS BEEN NOTED IN THE ABOVE CALCULATION, BUT AN ALTERNATIVE, REASONABLY CONSERVATIVE ACTUAL MAXIMUM OCCUPANCY (WHICH IS SUPPORTED BY THE OWNER'S HISTORICAL DATA) IS UTILIZED IN THE CALCULATION FOR
THE TOTAL OUTSIDE AIR CFM REQUIRED FOR THE RESPECTIVE ZONES.
ENERGY MANAGEMENT SYSTEM (EMS) DEVICES
DESCRIPTION COMMENTS
VENSTAR DC400, DATA CONCENTRATOR
VENSTAR CT414, COMMUNICATING THERMOSTAT
VENSTAR RS410, WALL MOUNT REMOTE TEMPERATURE SENSOR
VENSTAR ECP400, EQUIPMENT CONTROL PACK
VENSTAR OTS400, OUTDOOR TEMPERATURE SENSOR
LOCATE AT MANAGER'S WORK STATION. LOCATION SHOWN ON SHEET E-501, DETAIL 2.
RESPONSIBILITY
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR OPTIONAL SENSOR FOR WORKROOM. USE AS LAST RESORT ONLY IF NO SPACE EXISTS FOR WALL MOUNT TEMPERATURE SENSOR.
CONTRACTOR LOCATE ON ROOF IN SHADED LOCATION ON NORTH SIDE OF BUILDING.
VENSTAR RS420, OPTIONAL NARROW DROP DOWN SENSOR
CONTRACTOR
LOCATE AT EACH HVAC UNIT. LOCATION OF HVAC UNITS SHOWN ON SHEET M-101.
LOCATE BY MANAGER'S WORK STATION AS SHOWN ON M-101 AND E-103. COORDINATE LOCATION WITH STARBUCKS' EQUIPMENT.
LOCATE AS SHOWN ON M-1101, ONE PER HVAC UNIT. COORDINATE LOCATION WITH STARBUCKS' ART, EQUIP.; PROJECT MANAGER.
VENSTAR SP400, SENSOR PAC CONTRACTOR LOCATE COMPONENTS (AIRFLOW & TEMP SENSORS) PER SP400 SENSOR PAC INSTALLATION INSTRUCTIONS.
NOTES:
1.EMS DEVICES FURNISHED BY EMS VENDOR: VENSTAR. CONTACT: SBUXQUOTES@VENSTAR.COM, 818-812-9805. COMPONENTS INSTALLED BY CONTRACTOR.
2.THE SCHEDULED COMPONENTS SHALL BE PROVIDED FOR A COMPLETE AND FUNCTIONAL SYSTEM. SEE SPECIFICATION ABOUT EMS SYSTEM REQUIREMENTS.
ELECTRICAL / MECHANICAL COORDINATION NOTES:
PROVIDE AND COORDINATE LINE VOLTAGE WIRING, LINE VOLTAGE CONTROL AND INTERLOCK WIRING FOR MECHANICAL SYSTEMS, AND LOW VOLTAGE CONTROL WIRING.
FURNISH WIRING DIAGRAMS TO THE ELECTRICIAN AS REQUIRED FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE ELECTRICIAN THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL
EQUIPMENT (FROM THE EQUIPMENT NAMEPLATE) TO ENSURE PROPER INSTALLATION.
3 PIPE ROOF CURB DETAIL
N.T.S. (PROVIDED BY LANDLORD FOR REFERANCE ONLY)4 CONDENSER SUPPORT DETAIL
N.T.S. (PROVIDED BY LANDLORD FOR REFERANCE ONLY)
M-601
MECHANICAL
SCHEDULES
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-001GENERAL PLUMBING NOTES
1.PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL
CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS,
CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY
BECOME DAMAGED DURING THE COURSE OF WORK.
2.EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR
AREA UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT
CABINETS/DEVICES AND WHERE APPROVED BY STARBUCKS
CONSTRUCTION MANAGER. IF ROUTED THROUGH CABINETS, IT
SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE
PROTECTED FROM DAMAGE.
3.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR
ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL
COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A
COMPLETE AND OPERATING SYSTEM. OVERALL CASEWORK
COMPONENT DIMENSIONING ON PLUMBING DETAILS ARE SHOWN
FOR REFERENCE AND COORDINATION ONLY.
4.CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES
REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE
OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL
DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS.
5.THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK
WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER
DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR FIXTURES IN
CASEWORK AND PLUMBING DETAILS. SEE THE PROJECT MANUAL
FOR PLUMBING SPECIFICATION SECTIONS.
6.ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM
STRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS).
ABBREVIATIONS
GENERAL NOTES
SCOPE
THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO
PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM.
THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND
EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK.
SITE EXAMINATION
THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE
FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL
REPORT ANY CONDITION THAT, IN THEIR OPINION, PREVENTS THE PROPER
INSTALLATION OF THE PLUMBING WORK.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE
PROVISIONS OF CSA, ULC, ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA,
AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE
OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE
CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE
CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM
STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS.
PERMITS AND FEES
THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES,
AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK.
WARRANTY
THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO
BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD
OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY
STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS
AND WORKMANSHIP.
INSULATION
PIPING
PLUMBING FIXTURES
WATER FILTRATION
STARBUCKS WATER FILTRATION VENDOR WILL PROVIDE FILTRATION
SYSTEM. CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION
MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR IS TO INSTALL
FILTRATION SYSTEM. PROVIDE AND COORDINATE INSTALLATION COMPLETE
WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE DRAWINGS.
CONNECTIONS
THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO
EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES,
FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND
RIGID TUBING.
SCHEDULES
REFER TO SCHEDULES ON DRAWINGS FOR A DESCRIPTION OF LISTED ITEMS
AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC". ANY
DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE
SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR
CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO
SUPPLIES.
VALVES
GENERAL
PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON
PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND
COMPONENT ISOLATION. SEE PROJECT MANUAL FOR TYPES. INSTALL
VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED
STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE
AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT
FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT
MOVING EQUIPMENT. SHUT OFF VALVES TO BE BALL TYPE. VALVES SHALL
BE LISTED/APPROVED FOR USE PER AUTHORITIES HAVING JURISDICTION
(AHJ) AND CODE REQUIREMENTS. PROVIDE VALVE IDENTIFICATION PER
THE PROJECT MANUAL FOR MAIN WATER SERVICE SHUT-OFF AND ANY
OTHER VALVES WHICH ARE NOT CLEARLY EVIDENT WHAT THEY SERVE.
SUPPLY WATER SERVICE
IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI,
PROVIDE A PRESSURE REGULATOR IN MAIN SUPPLY TO REDUCE WATER
PRESSURE. PROVIDE BACKFLOW PREVENTION ON WATER SERVICE
IF REQUIRED BY LOCAL CODES.
THERMOSTATIC MIXING VALVE
PROVIDE A SINGLE THERMOSTATIC MIXING VALVE (TMV) LOCATED AT HOT
WATER TANK AND SET FOR 120° (OR AS REQUIRED BY AHJ) TO SERVE
HAND SINKS. MIXING VALVE TO BE INSTALLED PER MANUFACTURER’S
REQUIREMENTS WITH CHECK VALVES AT SUPPLY INLETS. PROVIDE
THERMOMETER ON OUTLET OF TMV. SEE THE PROJECT MANUAL FOR
REQUIREMENTS.
NITROGENATION
PLUMBING SYMBOL LEGEND
BALL VALVE
CONDENSATE DRAIN
DOMESTIC HOT WATER
DOMESTIC COLD WATER
CD NOTE: NOT ALL SYMBOLS MAY
BE USED
DOMESTIC HOT WATER RETURN
COLD WATERCW
WASTE BELOW GROUND
VENT
GREASE WASTEGSAN
NATURAL GASG
EXISTING PIPING(E)
WALL CLEAN OUT
FLOOR DRAIN
FLOOR SINK
BUTTERFLY VALVE
GAS SHUT OFF VALVE
ANGLE VALVE
GLOBE VALVE
MOTORIZED T.C. VALVE/2-WAY
MOTORIZED T.C. VALVE/3-WAY
PRESSURE REDUCING VALVE
SAFETY RELIEF VALVE
GATE VALVE
SWING CHECK VALVE
BACKFLOW PREVENTER
STRAINER
UNION
TEE UP
TEE DOWN
ELBOW UP
ELBOW DOWN
WATER METERM
WATER HAMMER ARRESTER (WHA)
HOSE BIBB, EXPOSED
CONNECT NEW WORK TO EXISTING(E)
POINT OF DISCONNECT(E)
PIPE CAP
TRAP PRIMER
PIPE BREAK
7.REFER TO OULTINE SPECIFICATIONS FOR PLUMBING SPECIFICATION
SECTIONS.
LEED
ALL WORK, MATERIALS AND EQUIPMENT SHALL MEET LEED
REQUIREMENTS & CODE. IN CASE OF CONFLICT, THE HIGHER STANDARD
SHALL APPLY.
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITIES HAVING JURISDICTION
APPROX APPROXIMATE
BLDG BUILDING
CLG CEILING
CONST CONSTRUCTION
CW DOMESTIC COLD WATER
CXA COMMISSIONING AGENT
DEG DEGREES
DN DOWN
DTL DETAIL
DWG(S)DRAWING(S)
EA EACH
EC ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
EMER EMERGENCY
EXIST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FS FLOOR SINK
F&I FURNISH & INSTALL
FLR FLOOR
FT FOOT/FEET
FCO FLOOR CLEANOUT
GC GENERAL CONTRACTOR
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GW GREASE WASTE
HR HOUR
HVAC HEATING, VENTILATION,
AND AIR CONDITIONING
HW HOT WATER
HS HANDSINK
HWS HOT WATER SUPPLY
HWR HOT WATER RETURN
LL LANDLORD
LV LOW VOLTAGE
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MFG MANUFACTURER
MIN MINIMUM
MS MOP SINK
NL NIGHTLIGHT
NTS NOT TO SCALE
PC PLUMBING CONTRACTOR
PS PREP SINK
POC POINT OF CONNECTION
REF REFERENCE
REQ’D REQUIRED
REV REVISION
SHT SHEET
SF SQUARE FEET
SPECS SPECIFICATION(S)
SST STAINLESS STEEL
TEL TELEPHONE
TEMP TEMPORARY
TMV TEMPERATURE MIXING VALVE
TW TEMPERED HOT WATER
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
V VENT
W SANITARY WASTE
WCO WALL CLEANOUT
WH WATER HEATER
WP WEATHER PROOF
WATER PIPING
PROVIDE THERMAL INSULATION PER THE SPECIFICATIONS. UNLESS
OTHERWISE REQUIRED BY THE LOCAL AUTHORITY OR ENERGY CODES, THE
MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS:
PIPE SIZE (DIAMETER)
LESS THAN OR EQUAL TO 1 1/2" (38MM)
2" (51MM) OR GREATER
(INSULATION VALUE = K VALUE NOT EXCEEDING 0.27 BTU* INCH (H*FT2*F)
SAFETY COVERS
MEP MECHANICAL, ELECTRICAL,
AND PLUMBING
SOIL, WASTE, AND VENT PIPING
SEE SPECIFICATIONS FOR PIPE MATERIALS. ALL HORIZONTAL RUNS SHALL
DRAIN AT A GRADE OF 1/4" PER FOOT (21MM PER METER) WHERE POSSIBLE
BUT IN NO CASE LESS THAN 1/8" PER FOOT (10MM PER METER) WHERE
ALLOWED & SIZED PER AHJ AND CODE.
COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS
FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR SINKS.
PROVIDE PIPED DRAIN (P-TRAP AND VENT) TO SANITARY IF REQUIRED BY
LOCAL JURISDICTION.
CONDENSATE DRAINAGE PIPING
THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR
AIR HANDLING UNITS AND STARBUCKS EQUIPMENT (REFER TO SCHEDULE).
CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH
WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER.
HANGERS AND SUPPORTS
THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS
REQUIRED FOR EQUIPMENT AND MATERIAL IN ACCORDANCE WITH
SPECIFICATIONS. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED
BY PIPE HANGERS INSTALLED AS REQUIRED BY LOCAL CODES. ADDITIONAL
SUPPORTS SHALL BE PROVIDED WHERE REQUIRED TO PREVENT SAGGING.
CONNECTIONS
INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO
EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO
CONNECT PIPING MATERIALS OF DISSIMILAR METALS.
CLEANOUTS
PROVIDE FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS
OR WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. SEE
SPECIFICATIONS FOR TYPES. CLEANOUTS SHALL BE SAME SIZE AS PIPE
EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED.
INSTALLATION
INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET
STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" (25MM)
OF CLEANING SPACE ALL AROUND PIPING, INCLUDING ANY ADDED PIPING
INSULATION. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH
CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH
CONCRETE AND MASONRY WALLS, GYPSUM BOARD PARTITIONS,
CONCRETE FLOOR AND ROOF SLABS. SEAL PIPE PENETRATIONS
THROUGH RATED CONSTRUCTION WITH FIRE
STOPPING SEALANT MATERIAL PER CODE REQUIREMENTS. DO NOT
INSTALL PEX PIPING IN RATED WALLS OR THROUGH RATED FLOORS.
INSTALL PER MANUFACTURER'S INSTRUCTIONS AND ENSURE PROPER
PROTECTION OF PEX PIPING FROM METAL EDGES. UNDERGROUND WATER
AND SEWER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM
HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE
PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL.
TESTING
ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE
BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING
CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS
REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL
REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR
REVIEW AND APPROVAL.
IDENTIFICATION
PROVIDE PIPE IDENTIFICATION EVERY 10 FT (EXCEPT WHERE PIPES ARE
EXPOSED TO PUBLIC) IN ACCORDANCE WITH SPECIFICATIONS.
INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH INSULATED FOAM LINER
AND TAMPER PROOF STRAP AS FURNISHED BY STARBUCKS AT ALL EXPOSED
ADA SINK P-TRAPS AND WATER SUPPLIES.
CWF FILTERED COLD WATER
CW
HW
HWR
SAN
V
STARBUCKS NITROGENATION VENDOR WILL PROVIDE AND INSTALL
EQUIPMENT AND FITTINGS, IF APPLICABLE, TO PROJECT SCOPE FOR
NITRO STATION. GENERAL CONTRACTOR SHALL COORDINATE NITRO
SYSTEM INSTALLATION WITH STARBUCKS VENDOR.
P-001
PLUMBING NOTES
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-101GENERAL NOTES
A.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PIPE CONDITIONS PRIOR TO
NEW CONSTRUCTION, INCLUDING EXACT LOCATION, PRESSURE, PIPE SIZE, AND
CAPACITY OF EXISTING SUPPLY LINES.
B.PRIOR TO INSTALLATION OF SEWER AND WATER PIPING BELOW GRADE
COORDINATE EXACT LOCATIONS AND DEPTHS OF BURIAL WITH CIVIL AND
FOUNDATION DRAWINGS AND CORRESPONDING ENGINEERS.
C.PRIOR TO DETAILING & INSTALLING PLUMBING AND FIRE PROTECTION PIPING
COORDINATE EXACT ROUTING AND ELEVATIONS WITH MECHANICAL,
ELECTRICAL AND FIRE SPRINKLER CONTRACTORS. PROVIDE WRITTEN
CONFIRMATION THAT THIS COORDINATION HAS BEEN IMPLEMENTED PRIOR TO
PROCEEDING WITH INSTALLATION OF PIPING.
D.FOR FILTERED WATER EQUIPMENT PROVIDE 1/2" CWF LINE THEN STEP DOWN
AT VALVE TO 3/8" OR AS SCHEDULED.
E.CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE
WATER SUPPLIED APPLIANCES AND EQUIPMENT. IE: ICE MACHINE, ESPRESSO
MACHINES, BREWERS, ETC SHALL BE PROVIDED WITH WATTS SD3 TYPE
BACKFLOW PREVENTER. ROUTE DRAIN TO FLOOR SINK OR INDIRECT
CONNECTION TO SEWER.
A. IN THE EVENT THAT THE PITCHER RINSER APPERATUS OUTLET IS BELOW
THE FLOOD RIM OF THE SINK IT SERVES, THE FAUCET SERVING IT SHALL
BE PROTECTED WITH A BACKFLOW PREVENTER SAME AS NOTED ABOVE.
B. WHERE REQUIRED BY THE JURISDICTION, PROVIDE EQUIPMENT WITH A
DOUBLE VENTED BACKFLOW PREVENTION DEVICE.
F.EACH FAUCET SHALL NOT EXCEED A WATER FLOW OF 1.8 GPM.
G.REFER TO SHEET P-001 FOR GENERAL HEALTH CODE REQUIREMENTS AT
EQUIPMENT CONNECTIONS.
PLUMBING WASTE NOTES
1.SEE PLUMBING SPECIFICATIONS FOR FURTHER REQUIREMENTS.
2.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE
TO CUSTOMERS EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT
EXPOSED CEILING AREAS.
3.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF
CONNECTIONS UNLESS OTHERWISE NOTED.
4.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER
CONNECTION TO ALL PLUMBING EQUIPMENT.
5.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
6.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN
CASEWORK.
7.WHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO A
FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING
ALL LINES ABOVE THE DRAIN.
8.FURNISH & INSTALL ALL NEEDED INDIRECT DRAINS PER CODE (NOT ALL
SHOWN). INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT
DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM
EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE
WITH AN AIR GAP PER CODE.
9.FURNISH & INSTALL WALL CLEANOUTS AT ALL SINKS AND AS NEEDED
AND PER CODE (NOT ALL SHOWN).
10.INSULATE ICE BIN DRAINAGE PIPES PER THE REQUIREMENTS ON THE
PLUMBING SPECIFICATION SHEET.
PLUMBING PLAN KEYED NOTES
1.CONNECT TO EXISTING GENERAL SANITARY WASTE MAIN NEAR THIS LOCATION. PC SHALL BE RESPONSIBLE TO
VERIFY LOCATION, INVERT AND PITCH PRIOR TO BEGINNING WORK.
2.CONNECT TO EXISTING GREASE SANITARY WASTE NEAR THIS LOCATION. PC SHALL BE RESPONSIBLE TO
VERIFY LOCATION, INVERT AND PITCH PRIOR TO BEGINNING WORK. SEE BUILDING SHELL PLANS FOR
INFORMATION ON EXISTING LANDLORD PROVIDED GREASE INTERCEPTOR.
3.EXISTING SANITARY VENT THRU ROOF NEAR LOCATION SHOWN. VERIFY EXACT LOCATION IN FIELD.
4.3/4" INDIRECT CONDENSATE DRAIN & 3/4" PRESSURE RELIEF VALVE FROM TANK TYPE WATER HEATER TO MOP
SINK. TERMINATE WITH AIR GAP.
5.3/4" INDIRECT DRAIN FROM WATER FILTRATION EQUIPMENT TO MOP SINK. TERMINATE WITH AIR GAP.
6.ROUTE INDIRECT DRAIN FROM FOOD SERVICE FIXTURE TO FLOOR SINK, SEE GENERAL NOTE D ON THIS SHEET.
7.3-COMP SINK TO DRAIN INDIRECTLY TO FLOOR SINK, EACH COMPARTMENT SHALL INDEPENDENTLY OF EACH
OTHER.
8.ROUTE INDIRECT DRAIN FROM COMBI-OVEN TO FLOOR SINK, WASTE PIPE SHALL BE COPPER TYPE L.
9.1/2" NITROGEN GAS LINE FROM NITROGEN GENERATOR TO NITRO WORKSTATION. FINAL CONNECTION BY
STARBUCKS VENDOR.
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.
RESTROOM 1
RESTROOM 2
DRIVE-THRU
P-101
PLUMBING WASTE PLAN
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-102 PLUMBING DESIGN PLAN NOTES
1.PLUMBING CONTRACTOR RESPONSIBLE TO FURNISH AND INSTALL A
COMPLETE AND OPERATIONAL SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
2.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION
PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK.
3.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT
VISIBLE TO CUSTOMERS.
4.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF
CONNECTIONS UNLESS OTHERWISE NOTED.
5.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER
CONNECTION TO ALL PLUMBING EQUIPMENT.
6.REFERENCE WORK LETTER FOR DIVISION OF PLUMBING SCOPE OF
WORK AND COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER.
7.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
8.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN
CASEWORK.
9.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE
COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL
CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT
WATER SUPPLY LINE INSULATION REQUIREMENTS.
10.GENERAL CONTRACTOR SHALL CONTACT WATER FILTRATION
SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO
INSTALLATION OF WATER FILTRATION SYSTEM.
GENERAL NOTES
A.ALL PLUMBING FIXTURES SHALL BE WATER CONSERVATION TYPE AS
MANDATED BY LOCAL BLDG. DEPT.
B.PRIOR TO INSTALLATION OF SEWER AND WATER PIPING BELOW GRADE
COORDINATE EXACT LOCATIONS AND DEPTHS OF BURIAL WITH EXISTING
FOUNDATIONS.
C.PRIOR TO DETAILING & INSTALLING PLUMBING AND FIRE PROTECTION
PIPING COORDINATE EXACT ROUTING AND ELEVATIONS WITH
MECHANICAL, ELECTRICAL AND FIRE SPRINKLER CONTRACTORS.
PROVIDE WRITTEN CONFIRMATION THAT THIS COORDINATION HAS BEEN
IMPLEMENTED PRIOR TO PROCEEDING WITH INSTALLATION OF PIPING.
D.WHETHER SHOWN OR NOT PROVIDE NEW INDIRECT WASTE FROM NEW
ICE-CHEST, ICE BIN(S), BAR SINKS WARE RINSER WATER TAP NITRO,
ESPRESSO MACHINES, ETC., TO ADJACENT FLOOR SINKS.
E.CONTRACTOR SHALL PROVIDE ALL PIPING FROM NEW FIXTURES TO
EXISTING WASTE LINES PER MATERIAL REQUIREMENTS ON SHEET P-601.
F.MAIN LINE SIZES ARE SHOWN. FOR WASTE AND VENT FIXTURE
CONNECTION SIZES REFER TO NEW PLUMBING FIXTURE SCHEDULE OR
MATCH ORIGINAL FOR RELOCATED ITEMS.
G.BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH
STATE AND LOCAL CITY REQUIREMENTS.
PLUMBING PLAN KEYED NOTES
1.CONNECT TO EXISTING BACKFLOW PREVENTER BY LANDLORD IN LEASE
SPACE AND EXTEND NEW 2" COLD WATER LINE THROUGH SPACE.
EXISTING METER ON SITE TO REMAIN.
2.(2) 3/4" COLD WATER WITH ASSE 1022 DOUBLE CHECK VALVE WITH
ATMOSPHERIC VENT TO FILTRATION EQUIPMENT WITH 3/4" FILTERED
WATER AND 3/4" COLD SOFTENED WATER OUT. PLUMBING
CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION
INSTRUCTIONS AND ACTIVATION PROCEDURES FOR BOTH SYSTEMS.
REFER TO FILTER CONNECTION DETAIL ON SHEET P-501.
3.INSTALL NEW ELECTRIC TANK-TYPE WATER HEATER ABOVE MOP
SINK/FILTRATION SYSTEM ON SHELF. SEE DETAILS ON SHEET P-501 FOR
ADDITIONAL INFORMATION.
4.PROVIDE THERMOSTATIC MIXING VALVE CONFIRMING TO ASSE 1070 AT
HAND SINK, SET DELIVERY TEMP TO 105°F MAX.
5.3/4" COLD FILTERED WATER WITH ASSE 1001 ATMOSPHERIC VACUUM
REAKER TO DISHWASHER. INSTALL SHUT-OFF WITH 3/4" MALE
HOSE-END FITTING @ 18" AFF UNDER COMPARTMENT SINK. SHUT-OFF
TO INCLUDE PRESSURE REDUCING VALVE, PRESSURE GAUGE (SET @
20 PSIG), LINE STRAINER, AND SHOCK ARRESTOR IN WALL. CONNECT
SANITIZER TO CSW SUPPLY WITH 72" LONG BRAIDED STAINLESS STEEL
HOSE.
6.3/4" FILTERED WATER TO FOOD SERVICE FIXTURE WITH ASSE 1022
DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT, EXTEND DISCHARGE
PIPING TO NEAREST FLOOR SINK. REDUCE CONNECTION TO 3/8" AT
FIXTURE.
7.3/4" FILTERED WATER TO ESPRESSO MACHINE PUMP. CONNECT 3/8"
COMPRESSION BRAIDED STAINLESS STEEL HOSE FROM SHUT-OFF TO
ESPRESSO MACHINE WATER INLET. SEE DETAIL PROVIDED ON SHEET
P-501.
8.3/4" FILTERED AND COLD WATER DOWN IN WALL TO BELOW SLAB.
PROVIDE 1/2" ELASTOMETRIC INSULATION ON PIPING BELOW SLAB AND
EXTEND 2" ABOVE FINISHED FLOOR. VERIFY ROUTING IN FIELD WITH
G.C. PRIOR TO INSTALLATION.
9.ROUTE 3/4" FILTERED AND COLD WATER PIPING THROUGH CABINETRY
AND CONNECT TO ITEMS 22642 (2), 11003 (2), 10153(2) & 19742 (2).
10.RECIRCULATION PUMP: BELL & GOSSETT # NBF-9U WET ROTOR-TYPE
INLINE PUMP WITH 2800 RPM MOTOR, LEAD-FREE BRONZE BODY WITH
UNION CONNECTIONS, CAPACITY OF 1 GPM AT 7 FEET OF HEAD.
PROVIDE WITH HONEYWELL #L6006C SURFACE MOUNTED AQUASTAT
WITH SINGLE POLE DOUBLE THROW SWITCH FOR CIRCULATOR
CONTROL AND ADJUSTABLE DIFFERENTIAL SET TO 10F. SET AQUASTAT
TO SHUT OFF RECIRCULATION PUMP AT WATER HEATER SET POINT
AND ON AT 10F BELOW SET POINT. SET AQUASTAT TO SHUT OFF
RECIRCULATION PUMP AT 3F ABOVE MIXING VALVE SET POINT AND ON
AT 7F BELOW SET POINT. ELECTRICAL REQUIREMENTS: 120-VOLT, 0.4
FULL LOAD AMPS.
11.BALANCING VALVE - HAYS "MEASUREFLO", MODEL #2519 COMBINATION
AUTOMATIC FLOW CONTROL VALVE AND BALL VALVE, SELF BALANCING,
AND FULLY AUTOMATIC WITHOUT ADDITIONAL PIPING OR CONTROL
MECHANISMS. SET 3/4" VALVE FOR 0.5 GPM FLOW.
12.PROVIDE COLD WATER CONNECTION TO COMBI-OVEN FOR CLEANING
FUNCTION AND FILTERED COLD WATER CONNECTION FOR INJUNCTION
FUNCTION. PROVIDE BACKFLOW PREVENTION DEVICE AS REQUIRED BY
LOCAL AHJ.
CAFE
ENGINE
WORKROOM
RESTROOM
VEST.RESTROOM 1
RESTROOM 2
DRIVE-THRU
P-102
PLUMBING SUPPLY
PLAN
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-401
P-401
PLUMBING ISOMETRICS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-402
P-402
PLUMBING ISOMETRICS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-501
5 ESPRESSO MACHINE GENERAL PIPING CONNECTION SCHEMATIC
N.T.S.
3 FLOOR CLEANOUT
N.T.S.
1 WALL CLEANOUT
N.T.S.2 FLOOR SINK DETAIL
N.T.S.
7 UNDERGROUND PIPE SUPPORT
N.T.S.
WATER HAMMER ARRESTOR
N.T.S.4
DOMESTIC COLD WATER
FROM WATER SERVICE
COLD WATER TO WATER HEATER, SEE
WATER HEATER DETAIL ON P-502.
STRAP-ON AQUASTAT
SET 5 DEGREES LOWER
THAN HEATER
TEMPERATURE
STRAINER
RECIRCULATION PUMP
RECIRCULATING HOT
WATER TO WATER
HEATER
NOTE:
INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. PIPING ARRANGEMENT SHOWN IS
SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS PUMP FITTING.
FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER
OPERATION WHEN INSTALLED.
VACUUM
BREAKER BY
PC
FL
O
W
FLOW
FL
O
W
FLOW
CHECK VALVE
CHECK VALVE
HOSE BIBB
Scale:NTS6HOT WATER RECIRCULATION PUMP
EXPANSION TANK, SEE WATER
HEATER DETAIL ON P-502.
P-501
PLUMBING DETAILS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-502
3'
-
0
"
M
I
N
.
C
L
R
.
(9
1
5
m
m
)
EQ.EQ.
WIRE STORAGE RACK;
LOCATE AND INSTALL
WALL MOUNT BRACKETS
PER MFR INSTRUCTIONS
4 TANK STORAGE
WALL BRACKET
WITH CHAIN
3/4" PLYWOOD
BACKER BOARD
BEHIND WALL FINISH.
FASTEN TO
STRUCTURE BEYOND.
1'
-
4
"
(4
0
5
m
m
)
7
1
/
4
"
(1
8
5
m
m
)
1'
-
5
1
/
2
"
(4
4
5
m
m
)
3'-0"
(915mm)
STORAGE TANKS BY
STARBUCKS VENDOR
GAS CYLINDER BRACING2N.T.S.
1'
-
0
"
(3
0
5
M
M
)
2'
-
0
"
(6
1
0
M
M
)
2'
-
0
"
(6
1
0
M
M
)
5'
-
7
1
/
2
"
(1
7
8
0
M
M
)
MOP SINK
HOT AND
COLD WATER
SUPPLY FOR
MOP FAUCET
HOSE CLIP
WIRE RACK
WATER HEATER
STRAP UNITS PER
LOCAL CODE
REQUIREMENTS
MOP HOLDER
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
FRP ENCLOSED
CHEMICAL
DISPENSING SYSTEM
COMPONENTS, TO
BE INSTALLED BY
SYSTEM VENDOR.
REFER TO POSTED
INSTALLATION
GUIDELINES FOR
MORE INFORMATION.
PAN AND DRAIN
FOR MAINTENANCE
7 MOP SINK (STACKED) - PLUMBING
N.T.S.
3'-3"(915MM)
8'
-
9
"
(
2
6
7
0
M
M
)
A.
F
.
F
.
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. POSITION BOOSTER PUMP SO THAT PRESSURE GAUGE IS READABLE AND ACCESSIBLE FOR TROUBLESHOOTING AND MAINTENANCE.
4. BOOSTER PUMP STATIC AND DYNAMIC OUTLET PRESSURE SHALL BE BETWEEN 65 TO 70 PSI. VERIFY PER PUMPS INTEGRAL PRESSURE GAUGE.
5. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
6. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED.
7. PROVIDE VIBRATION DAMPENING AT BOOSTER PUMP MOUNT TO PLATFORM.
WATER
HEATER TANK.
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INFORMATION.
GFCI 120V
RECEPTACLE
FOR BOOSTER
PUMP
2" (50MM)
MIN. CLEAR
CITY
WATER IN
OUT TO
WATER
FILTRATION
SYSTEM
BOOSTER PUMP.
SECURE TO
SHELF BELOW
WITH BOLTS
THROUGH BASE
PLATE
SHELF PER
ENGINEER'S
DRAWINGS
1 BOOSTER PUMP - PLUMBING
N.T.S.
3/4" (20MM)
CHROME ESCUTCHEONS (TYP.)
3/4" (20MM)
BRASS THREADED BALL SHUT-OFF VALVE
(TYP.) MAX 72" (1830MM) A.F.F.
UNION (TYP.)
3/4" (20MM)
FILTERED COLD WATER
TO ICE MACHINE
POINT OF USE
FILTER LOCATED AT
ICE MACHINE
MOP SINK
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS).
5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC.
6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER.
R.O. PERMEATE
TANK
7"
(180MM)
9 1/4"
(235MM)
GFCI 120V QUAD
RECEPTACLE FOR
FILTER SYSTEM 77"
(1955MM) A.F.F.
(SEE NOTE 3)FILTERED COLD WATER
TO FIXTURES (ESPRESSO
MACHINES, BREWERS,
HOT TAP, WATER TOWER
FAUCET)
75
"
(7
9
0
5
M
M
)
OUT
R.O. CONTROL SYSTEM
(SEE NOTE 5)
3/4" (20MM)
SHUT-OFF
VALVE
3/4" (15MM)
FIP
3/4" (20MM) SHUT-OFF VALVE
3/4" (20MM) BYPASS
3/4" (20MM) SHUT-OFF
VALVE
CITY WATER IN
TO NON FILTERED
FIXTURES (TOILETS,
HAND SINKS, DIPPER
WELLS, BLENDER
PITCHER RINSERS,
IN-COUNTER RINSERS,
BAR SINKS, HOSE BIBBS)
3/4" (20MM) FIP
(FEMALE
INTERNATIONAL
PIPE THREAD
FITTING) (TYP. 1 OF
2 TO SOFTENER)
GFCI 120V
RECEPTACLE FOR
FILTER SYSTEM AT
54" (1372MM) A.F.F.
(SEE NOTE 3)
IN
BRINE TANK (FRONT)
WATER SOFTENER
HEAD AND TANKS
(BEHIND)
DRAIN LINE FROM
WATER HEATER
TANK PAN ABOVE
11"
255MM)
3"(75MM)
WATER
HEATER TANK
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INORMATION
FROM WATER
HEATER TANK
TEMPERING
VALVE
OUT
IN IN
TO HOT WATER TANK
AND ADVANSYS
DISHWASHER
PLUMBING. SEE
WATER HEATER TANK
DETAIL FOR MORE
INORMATION
BYPASS VALVE
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
5'
-
0
"
(
1
5
2
5
M
M
)
TO R.O. SYSTEM
BOOSTER
PUMP
BYPASS
VALVE
3/4" (20MM)
CITY
WATER
IN
BOOSTER
PUMP
SHUT-OFF
VALVE
TO
BOOSTER
PUMP
3/4" (20MM)
BOOSTED
WATER IN
5'
-
9
"
(
1
7
5
0
M
M
)
WATER FILTRATION
BOOSTER PUMP.
SEE BOOSTER
PUMP DETAIL
FOR MORE
INFORMATION
CONFIGURATION III
WATER FILTRATION
SYSTEM. SEE
CONFIGURATION III, R.O.
AND SOFTENER DETAIL
FOR MORE
INFORMATION.
R.O. PERMEATE
TANK
FRP ENCLOSED
6"
(
1
5
0
M
M
)
CL
E
A
R
4'
-
2
"
(
1
2
7
0
M
M
)
BA
C
K
E
R
2'
-
6
"
(
7
6
5
M
M
)
7'
-
2
"
(
2
1
8
5
M
M
)
NOTE:
1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO
POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION
2'
-
0
"
(
6
1
0
M
M
)
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
STRAP UNITS PER LOCAL
CODE REQUIREMENTS
PROVIDE MOISTURE-
RESISTANT BLOCKING TO
STRUCTURE BEHIND
WALL FINISH AT THESE
AREAS. REFER TO ITEM
SPECIFICATIONS FOR
PLUMBING SCOPE;
COORDINATE INSTALL
WITH FILTER VENDOR.
FRP ENCLOSED
HOT WATER TANK. SEE
SPECIFICATIONS AND
WATER HEATER TANK
DETAIL FOR MORE
INFORMATION.
MOP HOLDER
3'
-
0
"
(
9
1
5
M
M
)
5'
-
0
"
(
1
5
2
5
M
M
)
HOSE CLIP
HOT AND COLD
WATER SUPPLY
FOR FAUCET
MOP SINK
SEE NOTE 1
BELOW
SEE NOTE 1
BELOW
2'-0"(610MM)
6'-0"(1830MM)
MIN.
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
WATER BOOSTER PUMP
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FRP ENCLOSED
9'
-
6
"
(
2
8
9
5
M
M
)
T
O
B
O
T
T
O
M
O
F
B
L
E
N
D
E
D
S
T
O
R
A
G
E
T
A
N
K
S
H
E
L
F
4 CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION 5 CONFIGURATION III
N.T.S.N.T.S.
EQ EQ
7"
EQ
EQ
3"
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 CWF STUB-UP
2 CW STUB-UP
ESPRESSO BAR PLUMBING STUB-UP KEY
1 2
POS DIEWALL
NOTE:SEE SHEET A102 - BUILDING
FLOOR PENETRATION PLAN FOR
FINAL DIMENSIONED LOCATION.
3-
3
/
4
"
3 PLUMBING STUB-UPS AT ESPRESSO BAR
N.T.S.
DIRECT DRAIN LINE FROM
SINK. ROUGH-IN SINK
WASTE STUB AT 15 1/2"
(394MM) A.F.F. AND
CENTERLINE OF SINK
TEMPERED HOT AND COLD
WATER FOR SINK FAUCET
AT 20 1/2" (520MM) A.F.F.
SHUT-OFF VALVES AT WALL
AND 4" (102MM) EITHER
SIDE OF WASTE LINE.
7 1/2"
1'-3"
CRAFT BAR CASEWORK DETAIL
6 ADD 02-01 PLUMBING
N.T.S.
P-502
PLUMBING DETAILS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-503
FILTERED
COLD WATER
SUPPLY FOR
ICE MACHINE
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO
FLOOR DRAIN
SEE PLUMBING PLAN
FOR FINAL FLOOR
DRAIN LOCATION
AND TYPE
.6" (152MM) MIN.
CLEAR TO BACK
WALL
6" (150MM) MIN.
CLEAR
.
PROVIDE
BACKFLOW
PREVENTION
DEVICE THEN
WATER
HAMMER
ARRESTOR
PRIOR TO
SHUT-OFF
VALVE AND
FLEX HOSE
CONNECTION
N.T.S.4 ICE MACHINE AND BIN - PLUMBING
HOT WATER TANK (SEE
SPECIFICATIONS & HOT WATER
TANK DETAIL FOR FURTHER
INSTALLATION REQUIREMENTS)
1" (25MM)
BRASS CHECK
VALVE
EXPANSION TANK
STRAP UNITS PER LOCAL
REQUIREMENTS
HOT WATER TO DISHWASHER
(IF OTHER THAN HOBART
ADVANSYS UNIT), BAR SINKS,
MOP SINK AND COMPARTMENT
SINK.
1" (25MM) HOT WATER OUTLET
TEMPERED HOT WATER TO
HAND SINKS
TEMPERATURE MIXING
VALVES
UNION (TYP.)CONCEALED
COPPER PIPING (TYP.)
IF CONFIGURATION II
OR III, SOFTENED
COLD WATER TO
DISHWASHER
(IF HOBART
ADVANSYS UNIT).
SEE NOTE 2 BELOW.
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
PAN AND DRAIN LINE FOR
MAINTENANCE
BOOSTER PUMP.
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FL
O
W
DI
R
E
C
T
I
O
N
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED..
SHELF PER
ENGINEER'S
DRAWINGS
FLOW
DIRECTION
5 WATER HEATER TANK - PLUMBING
N.T.S.
B
MOP SINK AND
WATER FILTRATION
EQUIPMENT. SEE
PLAN FOR ACTUAL
CONFIGURATION.
HOT WATER TANK SUPPORT
SHELF PER ENGINEER'S
DRAWINGS
WATER HEATER TANK PER PLAN
HOT WATER TANK CHASE TO
ROOF STRUCTURE ABOVE. PAINT
GWB FINISH TO MATCH BOH FRP.
ROOF STRUCTURE PER PLAN
SECTION B
2'-0"
CLEAR
7'
-
2
"
(
M
I
N
.
T
O
B
O
T
O
M
O
F
S
H
E
L
F
)
BOTTOM OF WORKROOM
CEILING IN FOREGROND
OPEN TO WORKROOM
A
SECTION A
OPTIONAL VCT CEILING.
HOLD TIGHT TO STRUCTURE
ABOVE
HOT WATER PIPING AND FLUE.
ENSURE ALL PENETRATIONS
THROUGH SURROUNDING WALLS
AND CEILING ARE COMPLETELY
SEALED.
CE
I
L
I
N
G
H
E
I
G
H
T
P
E
R
P
L
A
N
2"
BOOSTER PUMP
3 WATER HEATER TANK CHASE
N.T.S.
HOT AND COLD
WATER FOR SINK
FAUCET AT 20 1/2"
(520MM) A.F.F.
SHUT-OFF VALVES
AT WALL AND 4"
(100MM) EITHER
SIDE OF WASTE
LINE.
FILTERED COLD
WATER SUPPLY
FOR BREWER
WITH SHUT-OFF
IN CABINET AT
24" (610MM) A.F.F.
7'-6"
*
10"
FLOOR SINK
2'
-
5
1
/
2
"
FL
O
O
R
S
I
N
K
INDIRECT
DRAIN LINE
FROM
BREWER TO
FLOOR SINK
INDIRECT DRAIN LINE
FROM RINSE SINK TO
FLOOR SINK
SEE PLUMBING PLAN
FOR FINAL FLOOR
SINK LOCATION AND
TYPE CRAFT BAR CASEWORK DETAIL
PROVIDE BACKFLOW PREVENTION DEVICE THEN
WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF
VALVE AND FLEX HOSE CONNECTION
*
1 BRW 10-01 PLUMBING
N.T.S.
2'-6"
WORKSTATION TO UTILIZE SAME FLOOR SINK AS
ESPRESSO BAR. SEE BUILDING FLOOR
PENETRATION PLAN FOR SHARED LOCATION.
DRAIN LINES
FROM DRAIN
TRAY AND
UNDERCOUNTER
REFRIGERATOR;
SEPARATE,
INDIRECT
TERMINATION AT
FLOOR SINK
CRAFT BAR
CASEWORK
DETAIL
2 NIT 12-01 PLUMBING
N.T.S.
P-503
PLUMBING DETAILS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-504
Plan View
KEEP CLEAR FOR WALL MOUNTED CHEMICAL
DISPENSING SYSTEM, TO BE INSTALLED BY SYSTEM
VENDOR. PROVIDE BACKING BEHIND WALL FINISH
FOR EQUIPMENT MOUNTING. REFER TO POSTED
INSTALLATION GUIDELINES FOR MORE INFORMATION.
Elevation View
SOFTENED HOT AND NON-FILTERED
COLD WATER FOR SINK FAUCET
INDIRECT DRAIN LINE FROM
DISHWASHER TO NEAREST
FLOOR DRAIN OR MOP SINK.
BACK WALL
WATER FOR DISHWASHER WITH
SHUT-OFF UNDER SINK AT 18"
(460MM) AFF. LINE LENGTH MUST
ALLOW EASE OF MOVEMENT.
VERIFY WATER REQUIREMENTS
FOR TYPE OF DISHWASHER
(HOT/COLD/SOFTENED). SEE
WATER SUPPLY DRAWINGS FOR
WATER LINE. IF ADVANSYS
DISHWASHER, INCLUDE
PRESSURE REDUCING VALVE.
PRESSURE GAUGE (SET TO 20
PSIG +/- 5 PSI), LINE STRAINER
AND SHOCK ARRESTOR.
DRAIN LINE FROM SINK TO WASTE
LINE IN WALL OR TO FLOOR DRAIN
SEE PLUMBING PLAN FOR
FINAL FLOOR DRAIN LOCATION.
FLOOR DRAIN OPTIONAL.
WIRE RACK
COMPARTMENT
SINK
DISHWASHER
NOTE:
FOR COORDINATION ONLY. SEE
FURNITURE, FIXTURES, AND
EQUIPMENT PLAN FOR
EQUIPMENT LOCATIONS.
PROVIDE BACKING BEHIND WALL
FINISH AS REQUIRED FOR WALL
MOUNTED EQUIPMENT. REFER
TO ITEM SPECIFICATIONS FOR
MORE INFORMATION.
PRE-WASH STATION
4'
-
0
"
(1
2
2
0
M
M
)
1'
-
2
"
(3
5
5
M
M
)
4'
-
6
"
(1
3
7
0
M
M
)
DRAIN LINE FROM DISHWARE
DRYING RACKS TO SINK BOWL
DISHWARE DRYING RACKS
WITH DRAIN LINE TO SINK BOWL
ALIGN
3'
-
1
1
"
(1
1
9
5
M
M
)
3'
-
2
"
(9
6
5
M
M
)
11'-4"(3455MM)
3/4" PLYWOOD BACKER BOARD
BEHIND WALL FINISH. FASTEN
TO STRUCTURE BEYOND.
3 1/4"
(80MM)
3 SANITIZING (GENERIC) - PLUMBING
N.T.S.
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER FAUCET *
FILTERED
COLD WATER
SUPPLY FOR
INSTANT
HOT/COLD
WATER FONT
NON-FILTERED
HOT AND COLD
WATER SUPPLY
FOR SINK
FAUCET
ABOVE COUNTERTOP
AT FLOOR LEVEL
INDIRECT LINE
FROM PREP
SINK ABOVE TO
FLOOR SINK
SHELVING
ABOVE
FILTERED COLD
WATER SUPPLY FOR
UNDERCOUNTER
INSTANT HOT
WATER BOILER
(LOCATION MAY
VARY)
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
1 WATER FILLING STATION - PLUMBING
N.T.S.
11'-7"
ABOVE COUNTER
ICE BIN (TYP. 1 OF 2)NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
(TYP. 1 OF 2)
NON-FILTERED COLD WATER
SUPPLY FOR PITCHER
RINSER (TYP. 1 OF 2)
RINSER SINK (TYP. 1 OF 2)
2'
-
1
0
1
/
2
"
UNDER COUNTER
ICE BIN ABOVE
WITH INDIRECT
AND INSULATED
DRAIN LINE TO
FLOOR SINK
BELOW
7"X3" (180MMX75MM) STUB-UP
PENETRATION AREA. SEE
BUILDING FLOOR
PENETRATION PLAN FOR
FINAL LOCATION. INSTALL
SHUT-OFF VALVES BETWEEN
STUB-UPS AND EQUIPMENT
INDIRECT DRAIN LINE FROM
ESPRESSO MACHINE TO
FLOOR SINK
INDIRECT DRAIN LINE FROM
RINSER SINK TO FLOOR SINK
FLOOR SINK (TYP. 1 OF 2)
SEE PLUMBING PLAN FOR
FINAL LOCATIONS AND
TYPE
ICE BIN ABOVE
WITH INDIRECT AND
INSULATED DRAIN
LINE TO FLOOR
SINK BELOW
COUNTERTOP SUPPORT
LEG (TYP. 1 OF 3)
INDIRECT DRAIN
LINE FROM
RINSER SINK TO
FLOOR SINK
UNDERCOUNTER
CABINET
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
CRAFT BAR CASEWORK DETAIL
UNDERCOUNTER BOILER
FOR INSTANT HOT WATER
FONT (TYP 1 OF 2)
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
11 1/2"6'-1"
INDIRECT DRAIN LINE FROM
ESPRESSO MACHINE TO
FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR ESPRESSO
MACHINES
**
UNDERCOUNTER
CABINET
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER BOILER
(TYP. 1 OF 2)
*PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND
FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER
HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
2 ESP 10-01 PLUMBING
N.T.S.
P-504
PLUMBING DETAILS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P-505
1 CB WRM PLUMBING
N.T.S
2 CB CBE PLUMBING
N.T.S
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
DRAIN
SEE PLUMBING
PLAN FOR FINAL
FLOOR DRAIN
LOCATION AND
TYPE
.6" (152MM) MIN.
CLEAR TO BACK
WALL
INDIRECT DRAIN
LINE FROM ICE BIN
TO FLOOR DRAIN
INDIRECT DRAIN
LINE FROM ICE
DIVERTER TO
FLOOR DRAIN
ICE MACHINE
ICE TRANSPORT
TUBE BETWEEN ICE
MACHINE AND
DIVERTER VALVE.
MAX. LENGTH 10'
(3M)
ICE HEAD ADAPTER
ICE MANAGER
CONTROL PANEL
ICE TRANSPORT
TUBE LANE 2, TO
ICE BIN. MAX
LENGTH 75', MIN.
SLOPE 1/4":1'
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
3" PVC SLEEVE TO
SUPPORT ICE
TRANSPORT
TUBEFASTENED TO
WALL OR CEILING
W/ STRAPING @ 48"
O.C. MIN.
ICE DIVERTER
VALVE
ELEVATION - PLUMBING DIAGRAM
PLAN - PLUMBING DIAGRAM
CONT. FRP TO
CEILING ON BACK
WALL OVER IN
WALL BLOCKING
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
ECO-GRIP COVER
BASE
ACCESSIBLE
CLEARANCE AT
CONTROL PANEL
ICE MANAGER
CONTROL PANEL
ICE DIVERTER
VALVE
CONT. FRP ON
BACK WALL OVER
IN WALL BLOCKING
BACK WALL
r6
MIN.
BIN TOP SENSOR
DISTRIBUTION UNIT
ICE BIN
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
DRAIN
48
30
Scale: 3/4" = 1'-0"3 PLUMBING - NUGGET ICE - PEDESTAL STACK
78
FLOOR DRAIN
ELEVATION - PLUMBING DIAGRAM
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER INJECTION
WITH SHUT-OFF IN
CABINET AT 18" (457MM)
A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER
INJECTION WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
INDIRECT DRAIN LINE
FROM COMBI OVEN TO
FLOOR SINK
SEE PLUMBING PLAN
FOR FINAL FLOOR SINK
LOCATION AND TYPE
PLAN - PLUMBING DIAGRAM
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR DRAIN
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR DRAIN
SOFFIT
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR DRAIN
OUTLET BOX FOR
INDIRECT DRAIN
LINE
12
55
1
/
2
CEILING
OUTLET BOX FOR
INDIRECT DRAIN
LINE
ICE TRANSPORT TUBE
LANE 1, TO ICE
DISPENSER. MAX
LENGTH 75', MIN. SLOPE
1/4":1'.
CONTINUOUS CONDUIT
FASTENED W/ STRAPING
@ 48" O.C. MIN.
CEILING
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR DRAIN
SOFFIT
INDIRECT LINE FROM
DRAINBOARD TO FLOOR
SINK
HOT AND NON-FILTERED COLD
WATER FOR SINK FAUCET AT
20 1/2" (20MM) A.F.F. SHUT-OFF
VALVES AT WALL AND 4" (100MM)
EITHER SIDE OF WASTE LINE
NON-FILTERED COLD WATER SUPPLY
FOR BLENDER PITCHER RINSER
INDIRECT DRAIN LINE FROM SINK
TO FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR WATER TOWER
FAUCET
DRAIN LINES FROM
DRAIN TRAY AND
UNDERCOUNTER
REFRIGERATOR;
SEPARATE,
INDIRECT
TERMINATION AT
FLOOR SINK
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
ELEVATION - PLUMBING DIAGRAM
SECTION A - PLUMBING DIAGRAM
ACCESS
PANEL/DOOR
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
FRAMING, BLACK
ACCESS DOOR
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
CONTINUOUS CONDUIT
FASTENED W/ STRAPING
@ 48" O.C. MIN.
A
VA
R
I
E
S
138
6
6
EQ EQ
P-505
PLUMBING DETAILS
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description
P601
NEW EQUIPMENT NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL ACCESSORIES, FITTINGS, VALVES, ETC. AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. ALL ITEMS MAY NOT BE SHOWN OR REFERENCED.
2.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LAYOUTS, ELEVATIONS, FINISHES, ETC.
3.SEE PLANS FOR WASTE CONNECTION TYPE, EITHER DIRECT OR INDIRECT PER PLAN NOTES.
4.IND = INDIRECT TYPE WASTE CONNECTION.
P-601
PLUMBING SCHEDULES
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2023 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
ARCHITECT OF RECORD
THIS DRAWING IS A DESIGN
DEVELOPMENT DOCUMENT.
SITE SPECIFIC MODIFICATIONS
MADE UNDER THE RESPONSIBLE
CHARGE OF THE ARCHITECT
AND/OR ENGINEER-OF-RECORD
WILL BE REQUIRED PRIOR TO
USING THIS DOCUMENT FOR
BIDDING, PERMITTING, OR
CONSTRUCTION.
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS TEMPLATE VERSION: i2023.01.30
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
102442-001
05-01-2024
YE
L
M
&
K
I
L
L
I
O
N
14
0
6
E
Y
E
L
M
A
V
E
,
YE
L
M
,
W
A
9
8
5
9
7
84311
NJF
JEM
WHS
Revision Schedule
Rev Date By Description