Loading...
SB-TTS ROW WORK PLAN 2024-03-07CC C C C CC C C C C C C C CCCCEVEVEV EV EV EV EV EV EV C C C C C C C CC C CC TRACT A LOT 2 LO T 3 LO T 4 LOT 1 LOT 5 INDEX: JOB: SHEET: AGENCY NO. OF DR A W N B Y : CH E C K E D B Y : DE S I G N E D B Y : SC A L E : DA T E : VH EN G I N E E R S TE L : 3 6 0 . 9 4 3 . 1 5 9 9 F A X : 3 6 0 . 3 5 7 . 6 2 9 9 OL Y M P I A , W A 9 8 5 0 6 39 1 0 M A R T I N W A Y E , S U I T E B HA T T O N SU R V E Y O R S PA N T I E R ha t t o n p a n t i e r . c o m GO D A T AN D RE V I S I O N S : DA T E : TA H O M A T E R R A C O M M E R C I A L 50 A P O R T I O N O F T H E N W 1 / 4 O F T H E S W 1 / 4 A N D T H E N E 1 / 4 O F T H E SW 1 / 4 S E C T I O N 2 4 T O W N S H I P 1 7 N O R T H , R A N G E 1 E A S T , W . M . JE G / B S N AD B SE P T . 2 0 2 3 CP M H:\DGN\22-000\22-005\CDs 22-005 CITY OF YELM MERIDIAN HORIZONTAL DATUMVERTICAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM 22-005 wtr.dwg TP N # 7 8 6 4 0 0 0 0 0 1 2 , 7 8 6 4 0 0 0 0 0 1 0 CI T Y C O M M E N T S 12 / 1 3 / 2 3 PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 99 5 5 T A H O M A B L V D S E , Y E L M , W A 9 8 5 9 7 14 7 8 8 B E R R Y V A L L E Y R D S E , Y E L M , W A 9 8 5 9 7 CI T Y C O M M E N T S 3/ 7 / 2 4 OV E R A L L W A T E R P L A N NOTE: THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 811 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. THIS DRAWING DOES NOT REPRESENT A RECORD DOCUMENT, UNLESS CERTIFIED BY HATTON GODAT PANTIER. ANY ALTERATIONS TO THE DESIGN SHOWN HEREON MUST BE REVIEWED AND APPROVED BY HATTON GODAT PANTIER. TOPOGRAPHIC NOTE: THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. 24 0 SCALE: 1" = 50' 50 50 10025 1" = 5 0 ' N/ A TAHOMA BLVD SE BE R R Y V A L L E Y R D S E 8" WATERMAIN (TYP) FIRE HYDRANT (TYP) CONNECT TO EXISTING 10" WATERMAIN STUB CONNECT TO EXISTING 6" WATERMAIN STUB MULTI-FAMILY BUILDING (TYP) STORAGE UNIT (TYP) WETLAND BOUNDARY (CLIENT PROVIDED) WETLAND BUFFER (CLIENT PROVIDED) EXISTING FIRE HYDRANT (TYP) NHA T T O N GO D A T PA N T I E R WATER METER (TYP) D.I. FIRE SPRINKLER LINE (TYP) PIV (TYP) FDC (TYP) 10' UTILITY EASEMENT PR O P O S E D 20 ' U T I L E S M T P R O P O S E D 1 0 ' U T I L I T Y E A S E M E N T CONNECT TO EXISTING WATERMAIN STUB COF F E E SHO P RET A I L R E T A I L R E T A I L S T O R A G E O F F I C E FIRE HYDRANT (TYP) PIV (TYP) FDC (TYP) EXISTING RECLAIMED WATER VALVE & HYDRANT WATER SYSTEM MAP 1 300 CONNECT TO EXISTING 6" WATERMAIN STUB CONNECT TO EXISTING 10" WATERMAIN CONNECT TO EXISTING WATERMAIN STUB 8" WATERMAIN (TYP) 8" WATERMAIN (TYP) FIRE HYDRANT (TYP) EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN 8" WATERMAIN (TYP) CONNECT TO EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN EXISTING FIRE HYDRANT (TYP) CONNECT TO EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN STUB EXISTING 6" WATERMAIN STUB EXISTING 10" WATERMAIN STUB EXISTING 6" WATERMAIN STUB IRRIGATION METER (TYP) 4" SCH 40 CONDUIT W/ TRACER WIRE FOR IRRIGATION CROSSING (TYP) A B C D E F H G A B C D E K H F G J M L LEGEND NEW WATER MAIN NEW BUILDING FIRE LINE NEW WATER VALVE NEW HYDRANT NEW PIV NEW FDC NEW TEE NEW WATER SERVICE LINE NEW BEND W/ BLOCKING NEW REDUCER NEW WATER METER NEW RPBA 8" WATERMAIN (TYP) NEW RECLAIMED WATER LINE CONNECT TO EXISTING RECLAIMED WATER RECLAIMED WATERMAIN (TYP) 6" RECLAIMED WATER (TYP) RECLAIMED WATERMAIN (TYP) 6" RECLAIMED WATER (TYP) CONNECT TO EXISTING RECLAIMED WATERMAIN CONNECT TO EXISTING RECLAIMED WATERMAIN NEW BLOW-OFF ASSEMBLY IRRIGATION METER (TYP) 3/29/24