SB-TTS ROW WORK PLAN 2024-03-07CC C
C C
CC
C
C
C
C
C
C
C
CCCCEVEVEV
EV
EV EV
EV
EV
EV
C
C
C
C
C
C
C
CC
C
CC
TRACT
A
LOT 2
LO
T
3
LO
T
4
LOT 1
LOT 5
INDEX:
JOB:
SHEET:
AGENCY NO.
OF
DR
A
W
N
B
Y
:
CH
E
C
K
E
D
B
Y
:
DE
S
I
G
N
E
D
B
Y
:
SC
A
L
E
:
DA
T
E
:
VH
EN
G
I
N
E
E
R
S
TE
L
:
3
6
0
.
9
4
3
.
1
5
9
9
F
A
X
:
3
6
0
.
3
5
7
.
6
2
9
9
OL
Y
M
P
I
A
,
W
A
9
8
5
0
6
39
1
0
M
A
R
T
I
N
W
A
Y
E
,
S
U
I
T
E
B
HA
T
T
O
N
SU
R
V
E
Y
O
R
S
PA
N
T
I
E
R
ha
t
t
o
n
p
a
n
t
i
e
r
.
c
o
m
GO
D
A
T
AN
D
RE
V
I
S
I
O
N
S
:
DA
T
E
:
TA
H
O
M
A
T
E
R
R
A
C
O
M
M
E
R
C
I
A
L
50
A
P
O
R
T
I
O
N
O
F
T
H
E
N
W
1
/
4
O
F
T
H
E
S
W
1
/
4
A
N
D
T
H
E
N
E
1
/
4
O
F
T
H
E
SW
1
/
4
S
E
C
T
I
O
N
2
4
T
O
W
N
S
H
I
P
1
7
N
O
R
T
H
,
R
A
N
G
E
1
E
A
S
T
,
W
.
M
.
JE
G
/
B
S
N
AD
B
SE
P
T
.
2
0
2
3
CP
M
H:\DGN\22-000\22-005\CDs
22-005
CITY OF YELM
MERIDIAN HORIZONTAL DATUMVERTICAL DATUM
NGVD 29 PER T.C.H.P.N. #1252BM
BASED ON THRUSTON COUNTY HIGH PRECISION
NETWORK CONTROL POINT NO. 1252BM, 3" BRASS
CAP AT THE NW CORNER OF THE INTERSECTION OF
YELM HIGHWAY AND KILLION ROAD
ELEVATION = 246.39 (NGVD)
DATUM DATUM
22-005 wtr.dwg
TP
N
#
7
8
6
4
0
0
0
0
0
1
2
,
7
8
6
4
0
0
0
0
0
1
0
CI
T
Y
C
O
M
M
E
N
T
S
12
/
1
3
/
2
3
PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER
AUDITOR'S FILE NO. 4620459
99
5
5
T
A
H
O
M
A
B
L
V
D
S
E
,
Y
E
L
M
,
W
A
9
8
5
9
7
14
7
8
8
B
E
R
R
Y
V
A
L
L
E
Y
R
D
S
E
,
Y
E
L
M
,
W
A
9
8
5
9
7
CI
T
Y
C
O
M
M
E
N
T
S
3/
7
/
2
4
OV
E
R
A
L
L
W
A
T
E
R
P
L
A
N
NOTE: THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR
THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES.
THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR
TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE
LINE AT 811 A MINIMUM OF 48 HOURS PRIOR TO ANY
EXCAVATION.
THIS DRAWING DOES NOT REPRESENT A RECORD DOCUMENT,
UNLESS CERTIFIED BY HATTON GODAT PANTIER.
ANY ALTERATIONS TO THE DESIGN SHOWN HEREON MUST BE
REVIEWED AND APPROVED BY HATTON GODAT PANTIER.
TOPOGRAPHIC NOTE:
THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS
HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION
FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO
BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT
RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR
ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED
INTO THESE DRAWINGS AS A RESULT.
24
0
SCALE: 1" = 50'
50 50 10025
1"
=
5
0
'
N/
A
TAHOMA BLVD SE
BE
R
R
Y
V
A
L
L
E
Y
R
D
S
E
8" WATERMAIN
(TYP) FIRE HYDRANT
(TYP)
CONNECT TO EXISTING
10" WATERMAIN STUB
CONNECT TO EXISTING
6" WATERMAIN STUB
MULTI-FAMILY
BUILDING (TYP)
STORAGE
UNIT (TYP)
WETLAND BOUNDARY
(CLIENT PROVIDED)
WETLAND BUFFER
(CLIENT PROVIDED)
EXISTING FIRE
HYDRANT (TYP)
NHA
T
T
O
N
GO
D
A
T
PA
N
T
I
E
R
WATER METER
(TYP)
D.I. FIRE SPRINKLER LINE
(TYP)
PIV (TYP)
FDC (TYP)
10' UTILITY
EASEMENT
PR
O
P
O
S
E
D
20
'
U
T
I
L
E
S
M
T
P
R
O
P
O
S
E
D
1
0
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
CONNECT TO EXISTING
WATERMAIN STUB
COF
F
E
E
SHO
P
RET
A
I
L
R
E
T
A
I
L
R
E
T
A
I
L
S
T
O
R
A
G
E
O
F
F
I
C
E
FIRE HYDRANT
(TYP)
PIV (TYP)
FDC (TYP)
EXISTING
RECLAIMED
WATER VALVE
& HYDRANT
WATER SYSTEM MAP
1 300
CONNECT TO EXISTING
6" WATERMAIN STUB
CONNECT TO EXISTING
10" WATERMAIN
CONNECT TO EXISTING
WATERMAIN STUB
8" WATERMAIN
(TYP)
8" WATERMAIN
(TYP)
FIRE HYDRANT
(TYP)
EXISTING 10"
WATERMAIN STUB
EXISTING 10"
WATERMAIN
8" WATERMAIN
(TYP)
CONNECT TO EXISTING
10" WATERMAIN STUB
EXISTING 10"
WATERMAIN
EXISTING FIRE
HYDRANT (TYP)
CONNECT TO EXISTING
10" WATERMAIN STUB
EXISTING 10"
WATERMAIN
STUB
EXISTING 10"
WATERMAIN STUB
EXISTING 6"
WATERMAIN STUB
EXISTING 10"
WATERMAIN STUB
EXISTING 6"
WATERMAIN STUB
IRRIGATION METER (TYP)
4" SCH 40 CONDUIT W/ TRACER WIRE
FOR IRRIGATION CROSSING (TYP)
A
B C
D
E
F
H
G
A
B
C D
E
K
H
F
G
J
M
L
LEGEND
NEW WATER MAIN
NEW BUILDING FIRE LINE
NEW WATER VALVE
NEW HYDRANT
NEW PIV
NEW FDC
NEW TEE
NEW WATER SERVICE LINE
NEW BEND W/ BLOCKING
NEW REDUCER
NEW WATER METER
NEW RPBA
8" WATERMAIN
(TYP)
NEW RECLAIMED WATER LINE
CONNECT TO EXISTING
RECLAIMED WATER
RECLAIMED WATERMAIN (TYP)
6" RECLAIMED WATER (TYP)
RECLAIMED WATERMAIN (TYP)
6" RECLAIMED
WATER (TYP)
CONNECT TO
EXISTING RECLAIMED
WATERMAIN
CONNECT TO
EXISTING RECLAIMED
WATERMAIN
NEW BLOW-OFF ASSEMBLY
IRRIGATION METER (TYP)
3/29/24