Loading...
Fire Sprinkler Drawings-Tahoma Terra Storage Building J REV1WE T L A N D BU F F E R SI G N BE R R Y V A L L E Y R D S E TAHOMA BLVD SE ME T A L PI P E N52 ° 5 2 ' 1 4 . 0 0 " W 143 . 0 1 L=188.98,R=200.00 Δ=54°08'15.00" S1°16'01.00"W 33.44 33.77' 86. 7 7 ' L=225.83,R=239.00 Δ=54°08'15.00" L=346.02,R=645.00 Δ=30°44'14.87" L=370.58,R=600.00 Δ=35°23'17.00" 254.80' S1°42'11.00"W 254.80 L=284.52,R=715.00 Δ=22°47'58.00" L=266.61,R=670.00 Δ=22°47'58.00" L = 1 4 1.8 9, R = 6 7 0.0 0 Δ = 12°0 8'0 3.27" L=580.34, R =715.00 Δ = 46°30'19.00" S38 ° 4 6 ' 1 9 " E 458 . 8 2 N10°26'4 6 . 9 7 " E 93.40 S3°45'23.94"E 719.80 L = 5 7 2 . 2 5 , R = 6 0 0 . 0 0 Δ = 5 4 ° 3 8 ' 4 4 . 0 0 " L = 3 3 3 . 0 1, R = 6 4 5 . 0 0 Δ = 2 9 ° 3 4 ' 5 4 . 4 1 " L=152.13,R=161.00 Δ=54°08'15.00" 13.12' 86. 0 7 ' N8 8 ° 1 5 ' 1 5 . 0 0 " W 42 6 . 8 3 S0°10'55.02"E 775.14 S8 9 ° 4 9 ' 0 1 . 3 5 " W 35 . 0 0 S0°10'58.65"E 176.80 N43 ° 5 2 ' 2 1 . 9 4 " W 39.3 2 S10°47'04.2 8 " E 71.01 N 4 6 ° 0 7 ' 3 8 . 0 6 " E 4 3 . 4 3 S 4 6 ° 0 7 ' 3 8 . 0 6 " W 8 9 . 1 6 S43 ° 5 2 ' 2 1 . 9 4 " E 82.5 0 58.3 1 ' S6 5 ° 2 9 ' 5 1 . 0 4 " E 69 . 4 0 161 . 4 4 ' 82.8 3 ' S 4 6 ° 0 7 ' 3 8 . 0 6 " W 9 6 . 5 2 N11°06'0 2 . 1 0 " E 86.77 N3°19'40.25"W 62.90 N0°01'21.35"E 80.57 N3°57'08.77"W 137.42 N10°56'43.7 4 " W 134.27 N2°45'51.19"W 83.65 N1°46'50.79"W 105.08 N0°43'13.76"E 118.63 N42 ° 1 0 ' 5 3 . 6 8 " W 120 . 7 1 26.6 8 ' S8 8 ° 1 5 ' 1 5 " E 49 1 . 0 1 10 0 . 5 7 ' 24 3 . 3 3 ' 14 7 . 1 1 ' 20.00' S8 8 ° 1 5 ' 1 5 . 0 0 " E 29 . 1 5 TRACT "A" LO N G M I R E S T S E CB # 1 6 9 8 , T Y P E 1 RI M E L = 3 3 5 . 3 9 12 " H D P E ( W ) I. E . = 3 3 2 . 8 9 CB # 1 5 7 1 , T Y P E 1 RI M E L = 3 3 6 . 3 1 12 " H D P E ( S W ) I. E . = 3 3 3 . 5 3 L = 6 6 . 9 8 , R = 6 4 5 . 0 0 Δ = 5 ° 5 6 ' 5 8 . 4 6 " CB # 1 5 7 5 , T Y P E 1 RI M E L = 3 3 7 . 2 2 12 " H D P E ( N W ) I. E . = 3 3 4 . 4 2 CB # 1 5 7 6 , T Y P E 1 RI M E L = 3 3 8 . 6 0 12 " H D P E ( S ) I. E . = 3 3 5 . 9 0 RE C L A I M E D W A T E R VA L V E RE C L A I M E D W A T E R HY D R A N T A B C D E F H G A B C D E K H F G J M L CC C C C CC C C C C C C C CCCCEVEVEV EV EV EV EV EV EV NOTE: THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 811 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. THIS DRAWING DOES NOT REPRESENT A RECORD DOCUMENT, UNLESS CERTIFIED BY HATTON GODAT PANTIER. ANY ALTERATIONS TO THE DESIGN SHOWN HEREON MUST BE REVIEWED AND APPROVED BY HATTON GODAT PANTIER. WATER SYSTEM MAP 1�� �� 300�� CONNECT TO EXISTING 6" WATERMAIN STUB CONNECT TO EXISTING 10" WATERMAIN CONNECT TO EXISTING WATERMAIN STUB 8" WATERMAIN (TYP) EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN 8" WATERMAIN (TYP) CONNECT TO EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN STUB EXISTING 6" WATERMAIN STUB LEGEND NEW WATER MAIN NEW BUILDING FIRE LINE NEW WATER VALVE NEW HYDRANT NEW PIV NEW FDC NEW TEE NEW WATER SERVICE LINE NEW BEND W/ BLOCKING NEW REDUCER NEW WATER METER NEW RPBA VERTICAL DATUM MERIDIAN HORIZONTAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 0 SCALE: 1" = 50' 50 25 50 100 HA T T O N GO D A T PA N T I E R TOPOGRAPHIC NOTE: THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, HGP CANNOT ENSURE ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 6" FLANGE TO 1'-0" AFF F.D.C. LINE 6" FLANGE TO 1'-0" AFF BLDG 'B' BLDG 'A' BLDG 'C'BLDG 'D'BLDG 'H'BLDG 'J' BLDG 'L'BLDG 'K' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM FIRE SPRINKLER RISER ROOM 8" WATERMAIN FIRE HYDRANT (TYP) (TYP) CONNECT TO EXISTING 10" WATERMAIN STUB CONNECT TO EXISTING 6" WATERMAIN STUB MULTI-FAMILY BUILDING (TYP) STORAGE UNIT (TYP) EXISTING FIRE HYDRANT (TYP) WATER METER (TYP) D.I. FIRE SPRINKLER LINE (TYP) PIV (TYP) FDC (TYP) FIRE HYDRANT (TYP) PIV (TYP) FDC (TYP) 8" WATERMAIN (TYP) FIRE HYDRANT (TYP) CONNECT TO EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN STUB EXISTING 10" WATERMAIN STUB EXISTING 6" WATERMAIN STUB IRRIGATION METER (TYP) 4" SCH 40 CONDUIT W/ TRACER WIRE FOR IRRIGATION CROSSING (TYP) 8" WATERMAIN (TYP) Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E F A C I L I T Y TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 05 / 1 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 OVERALL SITE PLAN Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 50'-0" PROJECT NORTH OVERALL SITE PLAN 0 100'50'25' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.0 BW / J G F PROJECT INFORMATION: COMMERCIAL SELF-STORAGE FACILITY WITH 12 BUILDINGS. BUILDINGS A, B, C, D, H, J, K, L ARE FULLY SPRINKLERED BUILDINGS E, F, G, M ARE NON-SPRINKLERED. Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: FLOW TEST INFORMATION 06/10/2024 1 4 11+ 0 0 12 + 0 0 PI 10+42.00 P I 1 1 + 1 4 . 6 7 PI 12+42.53 PI 12+65 . 5 4 16+00 17+00 18+00 19+00 20+00 21+00 22+00 22+92 C/L INT 12+00.00 (N) = 22+18.48 (W) D E K H G J M L VERTICAL DATUM MERIDIAN HORIZONTAL DATUM NGVD 29 PER T.C.H.P.N. #1252BM BASED ON THRUSTON COUNTY HIGH PRECISION NETWORK CONTROL POINT NO. 1252BM, 3" BRASS CAP AT THE NW CORNER OF THE INTERSECTION OF YELM HIGHWAY AND KILLION ROAD ELEVATION = 246.39 (NGVD) DATUM DATUM PLAT OF TAHOMA TERRA PHASE 2, DIVISION 2 UNDER AUDITOR'S FILE NO. 4620459 0 SCALE: 1" = 30' 30 15 30 60 SEE SHEET 29 SEE SHEET 29 10 ' U T I L I T Y E A S E M E N T 10' UTILITY EASEMENT 10' UTILITY EASEMENT 10' UTILITY EASEMENT 198 LF 8" PVC WATER 239 LF 8" PVC WATER 22+18.48, 2.50' RT (W) = 12+02.17, 0.00' RT (N) INSTALL 1 - 8" TEE (FL) 1 - 8" ADAPTER (FLxMJ) 2 - 8" GV (FLxMJ) BLOCKING TA H O M A B L V D . EA S T WE S T NORTH NE KEY MAP N.T.S. LO N G M I R E HA T T O N GO D A T PA N T I E R 84 LF 8" PVC WATER INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY BLOCKING 17+39.24, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (17+39.24, 109.00' LT) BLOCKING 15+41.22, 99.00' LT INSTALL 1 - 8"x6" REDUCER (MJxFL) 1 - 6" GV (FLxRMJ) 1 - HYDT ASSEMBLY (STD DWG 4-7) (15+41.22, 109.00' LT) BLOCKING 15+41.22, 59.58' LT (W) INSTALL 1 - 4" 90 DEG ELL (MJ) 40 LF 4" D.I. FIRELINE TO BLDG D BLOCKING DCDA LOCATED INSIDE BUILDING SEE FIRE PROTECTION PLANS 19 LF 8" PVC WATER MAIN 117 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 30 LF 4" DI FDC LINE FROM BLDG K RISER ROOM TO FDC 18+47.90, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG K") 18+64.93, 47.50' RT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG L") 30 LF 4" DI FDC LINE FROM BLDG L RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 34 LF 8" PVC WATER 123 LF 8" PVC WATER DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 5 LF 4" DI FDC LINE FROM BLDG H RISER ROOM TO FDC 5 LF 4" DI FDC LINE FROM BLDG J RISER ROOM TO FDC DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANS 17+39.33, 2.50' RT (W) INSTALL 1-8" TEE (FL) 2- 8" GV (FLxMJ) 1 -8" ADAPTER 1 - 8"x4" TEE (FLXMJ) 1 - 8"x6" REDUCER (FL) 1 -6" GV (FLxRMJ) 1 - 12LF 6" D.I. PIPE 1 HYDT ASSEMBLY (STD DWG 4-7)(18+56.43, 47.50' RT) BLOCKING 19+79.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING 15+41.22, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) 19+79.22, 82.00' LT (W) INSTALL 1 - 8"x4" CROSS (MJ) 25LF 4" D.I. FIRELINE TO BLDG H 25LF 4" D.I. FIRELINE TO BLDG J BLOCKING 18+56.43, 2.50' RT (W) INSTALL 1 - 8" TEE (FL) 2 - 8" GV (FLxMJ) 1 - 8" ADAPTER (FLxMJ) BLOCKING BLDG 'D' BLDG 'H' BLDG 'J' BLDG 'K'BLDG 'L' EX I T 2' 1. 5 ' 1.5' 8.17' 34 . 3 1 ' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 1 9 ' 2' 1. 1 9 ' 1.5'8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 1. 4 8 ' 8. 0 9 ' 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" WATER MAIN 8" W A T E R M A I N INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG H") INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG J") FIRE SPRINKLER RISER ROOM F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' F.D.C. LINE 4" FLANGE TO 1'-0" AFF 8" W A T E R M A I N 8" W A T E R M A I N FIRE SPRINKLER RISER ROOM 57 LF 4" DI FDC LINE FROM BLDG D RISER ROOM TO FDC 15+53.22, 109.00' LT INSTALL 1 - 4"x 2½"x2½" FDC (CONTRACTOR TO CLEARLY LABEL "BLDG D) 18+56.43, 36.00' RT (W) INSTALL 1 - 4" TEE (FLxMJ) 24LF 4" D.I. FIRELINE TO BLDG K 24LF 4" D.I. FIRELINE TO BLDG L J DCDA LOCATED INSIDE BUILDING SEE MECHANICAL PLANSBLDG 'H' BLDG 'J' 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER RISER ROOM FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF 2' 1. 5 ' 1.5' 8.17' FIRE SPRINKLER WET SYSTEM 4" FLANGE TO 1'-0" AFF F.D.C. LINE 4" FLANGE TO 1'-0" AFF BLDG 'F'BLDG 'G' 4" FLANGE TO 1'-0" AFF FIRE SPRINKLER RISER ROOM Da t e : Co r p o r a t i o n Sp r i n k l e r A F i r e Dr a w n : Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1" = 40'-0" WA. STATE LEVEL 3 STAMP F L File:Tahoma Terra Storage Site FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " J " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 05 / 1 0 / 2 0 2 3 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "J" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1" = 30'-0" PROJECT NORTH BUILDING "J" FIRE PROTECTION SITE PLAN 0 60'30'15' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O FP-1.1 BW / J G F SCALE: 1" = 10'-0" PROJECT NORTH BLDG "J" ENLARGED FIRE PROTECTION SITE PLAN 0 20'10'5' 13 C7 FIRE DEPARTMENT CONNECTION (FDC) 36"-42" UNDERGROUND STUB UP W/ ROD D. I . P . R I S E R L C CONC. FOOTING FOW ATR & TIE BOLTS OR- MEGA-LUG RETAINERS TO RESTRAIN VERTICAL PIPING 36 " M I N I M U M CORE OR SLEEVE THRU FOOTING IF REQUIRED THRUST BLOCK (PER NFPA 24) PIPE SLEEVE THRU SLAB MAINTAIN 2" GAP AROUND FIRE LINE FLANGE 1'-0" AFF SLAB LEVEL EXT. WALL 1'-8" MINIMUM U.G. PIPING UNDERGROUND NOTES: 1) ALL UNDERGROUND BY OTHERS. Contractor to be State Licensed and Certified to install Underground Piping Per WAC 212-80. 2) Pipe type and class to meet Local Jurisdiction Approval. 3) All underground piping shall have a Minimum 3'-0" Bury. 4) All underground piping shall be U.L. Listed and/or FM Approved for Fire Protection. 5) All underground piping shall be rodded and/or blocked in accordance with the specifications and NFPA 24. 6) All underground piping shall be Hydrostatically tested at not less than 200 PSI for two hours in accordance with NFPA 24. 7) All underground piping shall be flushed in accordance with NFPA 24. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 8) All underground installation and testing to be witnessed by the local authority having jurisdiction. 9) Where pipes passes through holes in foundations, walls, or floors, the holes or sleeve shall be sized 4 in. larger than the supply pipe size on pipes sized 4" or larger. HEAD BOX N.T.S. RISER DETAIL RISERD UNDERGROUND STUB UP 2½" ANGLE HOSE VALVE FOR FORWARD FLOW TESTING OF DCVA. 4" GROOVED CHECK VALVE DR A I N TO 4" FLANGE x GROOVED ADAPTER 4" DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY INDOOR VERTICAL INSTALLATION w/(2) BUTTERFLY TAMPER SWITCHES 4" RISER MANIFOLD W/: (1)DRAIN AND TEST (2)FLOW SWITCH (3)WATER GAUGE (4)SIGNS ON BODY (5)PRV- KIT 4" GRVD 90º ELBOW *Pressure Relief Valve installed on System Riser -or- at Inspectors Test Valve. See Detail EXTERIOR 6" 24V AC ALARM BELL FIRE LINE BY OTHERS MJ ELBOW w/Restrained Flange Adapters MJ ELBOW w/Restrained Flange Adapters Hoffman Construction, Inc. 159 16th Street East, Suite 101 Pacific, WA 98047-5005 PHONE: 360-825-9797 Randy Hoffman Certification #3966-0899-D Certification Level: U Contractor # HOFFMCI931D9 WA STATE LEVEL U INSTALLATION COMPANY INFO: VICINITY MAP N.T.S. F.D.C. BUILDING 'H' F.D.C. BUILDING 'J' FIRE HYDRANT 06/10/2024 2 4 WW Co r p o r a t i o n Sp r i n k l e r A F i r e Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1/8" = 1'-0" WA. STATE LEVEL 3 STAMP File:Tahoma Terra Storage Bldg J FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " J " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 05 / 1 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "J" Sheet Number: Sheet Title: Project No.24-012CM SCALE: 1/8" = 1'-0"0 16'8' PROJECT NORTH BUILDING "J" FIRE SPRINKLER FLOOR PLAN 4' (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O VICTAULIC V2704, QR K=5.6, 1/2" NPT, (55,6 mm) 2-3/16" BRASS UPRIGHT ºF STEEL Z-PURLIN MAIN HANGER ROD TRAPEZE NTS H32S TRAPEZE PIPE, SIZED ALL-THREAD ROD, SIZED PER NFPA #13 AND NUTS (TYPICAL) PER NFPA #13 STEEL SWDR 1" ADJUSTABLE RING HANGER SAMMY SCREW SIDEWINDER FIG. 200 HANGER DETAIL PER NFPA #13 ALL-THREAD ROD, SIZED PIPE RING SAMMY STEEL SIDEWINDER SWDR 1" W/NUT, OR EQUAL. 4"∅ MAX BRANCH LINE METAL ROOF DECK 3/8"Ø x 0-8" ALL THREADED ROD 'Z' PURLIN Notes:___________________________________________________________________________________________________ 1. SYSTEM TYPE: WET SYSTEM THROUGHOUT STORAGE BUILDINGS A, B, C, D, H, J, K, L. BUILDINGS ARE CONSTRUCTED OF ALL NON-COMBUSTIBLE TYPE V-B CONSTRUCTION MATERIALS. NO VOID SPACES ABOVE CEILINGS THAT WILL REQUIRE SPRINKLER PROTECTION. SPRINKLER SYSTEM DESIGNED AND INSTALLED PER NFPA-13, ORDINARY HAZARD GROUP 2 OCCUPANCY THROUGHOUT EACH BUILDING. NO HIGH PILE STORAGE, FLAMMABLE LIQUIDS OR HIGHLY COMBUSTIBLE MATERIAL STORED ON FACILITY. PROPOSAL BASED ON PROVIDING A FIRE SPRINKLER HEAD IN EACH STORAGE UNIT. OWNER MUST MAINTAIN STORAGE HEIGHTS TO 18” BELOW FIRE SPRINKLER HEAD DEFLECTORS. 2. CONSTRUCTION TYPE: V-B NON-COMBUSTIBLE, UNOBSTRUCTED. 3. SPRINKLER SYSTEM DESIGNED, INSTALLED, BRACED AND TESTED PER NFPA-13 (2016). 4. ALL MATERIAL SHALL BE NEW AND U.L. LISTED AND F.M. APPROVED. 5. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, IT IS THE CONTRACTORS & OWNERS RESPONSIBILITY TO INSULATE WET SYSTEMS PROPERLY & TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVE CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 6. SPRINX FIRE PROTECTION SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. SPRINX FIRE PROTECTION STARTS AT A 6" FLANGE CONNECTION 1'-0" AFF. 7. ALL ELECTRICAL, PAINTING, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 8. PIPE SIZING PER NFPA-13, SYSTEM HYDRAULICALLY CALCULATED. 9. EARTHQUAKE BRACING PER NFPA-13 (2016) 10. ONLY NEW SPRINKLERS SHALL BE EMPLOYED IN THE INSTALLATION OF THE SPRINKLER SYSTEM. 11. A STOCK OF SPARE SPRINKLERS OF EACH STYLE, TYPE, AND TEMP. RATING ALONG WITH A SPRINKLER HEAD WRENCH SHALL BE LOCATED AT THE MAIN RISER. 12. ALL MAINS PIPING 21 2"- 4" IN SIZE TO BE BULL MOOSE TUBE EDDY FLOW THINWALL PIPE. ALL MAIN PIPING TO HAVE FIRELOCK GROOVED FITTINGS WITH WELDED OUTLETS 13. ALL LINE PIPING 1" - 1-1/4 " IN SIZE TO BE SCH-40, THREADED PIPE, WITH CAST OR DUCTILE IRON THREADED FITTINGS. GRID OR TREE LINE PIPING 1-1/2 " - 2" TO BE BULL MOOSE TUBE EDDY FLOW THINWALL PIPE. 14. LOWER FLOOR PIPE HANGERS TO BE HILTI KWIK CAST-IN ANCHORS KCS-WF, OR CEILING FLANGES IMBEDDED IN CONCRETE ROD AND RINGS. 15. UPPER FLOOR OR SINGLE STORY BUILDING HANGERS TO BE STEEL SAMMY SIDEWINDERS SWDR-1", ROD AND RINGS. (SEE HANGER DETAILS) 16. ALL PIPE DIMENSIONS ARE CENTER TO CENTER LENGTHS. 17. ALL ABOVE GROUND PIPING TO BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS. TESTING AND PIPE INSTALLATION INSPECTED BY LOCAL FIRE MARSHAL. 18. TOTAL AREA PROTECTED BY WET PIPE SYSTEM BUILDING "J" 14,850 SQ. FT. 19. OWNER TO MAINTAIN STORAGE TO A MINIMUM 18" BELOW FIRE SPRINKLER SYSTEM. OWNER TO INSTALL METAL BAFFLE IF SPRINKLERS ARE LESS THAN 6'-0" SPACES. OWNER TO ENSURE EXTRA HAZARD MATERIALS ARE NOT STORED IN FACILITY. ATTACHMENT TO STRUCTURE : ATTACH WITH 1/2" X 6" ALL THREAD ROD ATTACHED TO: TOP CHORD OF Z-PURLIN WITH UNI-STRUT BACKER & 1/2" NUTS AND WASHERS 1 1/4" SCHEDULE 40 PIPE UP TO 9'-0" LONG 1" SCHEDULE 40 PIPE UP TO 7'-0" LONG TOLCO FIG. 980 SWIVEL UNIV. SWAY BRACE ATTACHMENT TOLCO FIG. 1001 FAST CLAMP MATERIAL : ATTACH TO STEEL I-BEAM WITH TOLCO FIG.828 - OR - Hydraulically Calculated System This system as shown on company print no dated for contract noat is designed to discharge at a rate of GPM (Lmin) per sq ft (m2) of floor area over a maximum area of sq ft (m2) when supplied GPM (L/min)with water at the rate of at psi (bars) at the base of the riser Hose stream allowance of GPM (L/min) is included in the above. Occupancy Classification Commodity Classification Maximum Storate Height Installed By: SPRINX FIRE PROT, INC. FP-2.0 05/10/2024 TAHOMA TERRA BLDG-J REMOTE AREA#1 24-012CMBUILDING J STORAGE .20 945 288.62 42.35 250 ORDINARY GP-2 I-III 8'-0" SPRINX FIRE PROTECTION, INC. FP-2.0 BW / J G F 06/10/2024 Co r p o r a t i o n Sp r i n k l e r A F i r e Fa x 2 5 3 . 8 5 3 . 5 8 9 0 Ph o n e 2 5 3 . 8 5 3 . 7 7 8 0 27 0 9 J A H N A V E , N W , S U I T E H 2 Gi g H a r b o r , W A . 9 8 3 3 5 - 1 7 3 5 Co n t . L i c . # S P R I N F P 0 1 1 L S FI R E S P R I N K L E R D R A W I N G SCALE: 1/8" = 1'-0" WA. STATE LEVEL 3 STAMP File:Tahoma Terra Storage Bldg J FP.dwg TA H O M A T E R R A S T O R A G E B U I L D I N G " J " TA H O M A B O U L E V A R D YE L M , W A 9 8 5 9 7 05 / 1 0 / 2 0 2 4 PA C I F I C S T O R A G E P A R T N E R S , L L C P. O . B O X 7 3 7 9 0 PU Y A L L U P , W A 9 8 3 7 3 PA P CI T Y O F Y E L M B L D G / F I R E O F F I C I A L (3 6 0 ) 3 3 9 - 2 0 9 5 BLDG "J" Sheet Number: Sheet Title: Project No.24-012CM (2 5 3 ) 2 2 3 - 7 4 3 2 CH R I S V A C C A R O VICTAULIC V2704, QR K=5.6, 1/2" NPT, (55,6 mm) 2-3/16" BRASS UPRIGHT FP-3.0 BW / J G F SCALE: 1/4" = 1'-0"0 8'4' BUILDING "J" FIRE SPRINKLER SECTION "A" PLAN 2' STEEL Z-PURLIN MAIN HANGER ROD TRAPEZE NTS H32S TRAPEZE PIPE, SIZED ALL-THREAD ROD, SIZED PER NFPA #13 AND NUTS (TYPICAL) PER NFPA #13 STEEL SWDR 1" ADJUSTABLE RING HANGER SAMMY SCREW SIDEWINDER FIG. 200 HANGER DETAIL PER NFPA #13 ALL-THREAD ROD, SIZED PIPE RING SAMMY STEEL SIDEWINDER SWDR 1" W/NUT, OR EQUAL. 4"∅ MAX BRANCH LINE METAL ROOF DECK 3/8"Ø x 0-8" ALL THREADED ROD 'Z' PURLIN ATTACHMENT TO STRUCTURE : ATTACH WITH 1/2" X 6" ALL THREAD ROD ATTACHED TO: TOP CHORD OF Z-PURLIN WITH UNI-STRUT BACKER & 1/2" NUTS AND WASHERS 1 1/4" SCHEDULE 40 PIPE UP TO 9'-0" LONG 1" SCHEDULE 40 PIPE UP TO 7'-0" LONG TOLCO FIG. 980 SWIVEL UNIV. SWAY BRACE ATTACHMENT TOLCO FIG. 1001 FAST CLAMP MATERIAL : ATTACH TO STEEL I-BEAM WITH TOLCO FIG.828 - OR - Notes:___________________________________________________________________________________________________ 1. SYSTEM TYPE: WET SYSTEM THROUGHOUT STORAGE BUILDINGS A, B, C, D, H, J, K, L. BUILDINGS ARE CONSTRUCTED OF ALL NON-COMBUSTIBLE TYPE V-B CONSTRUCTION MATERIALS. NO VOID SPACES ABOVE CEILINGS THAT WILL REQUIRE SPRINKLER PROTECTION. SPRINKLER SYSTEM DESIGNED AND INSTALLED PER NFPA-13, ORDINARY HAZARD GROUP 2 OCCUPANCY THROUGHOUT EACH BUILDING. NO HIGH PILE STORAGE, FLAMMABLE LIQUIDS OR HIGHLY COMBUSTIBLE MATERIAL STORED ON FACILITY. PROPOSAL BASED ON PROVIDING A FIRE SPRINKLER HEAD IN EACH STORAGE UNIT. OWNER MUST MAINTAIN STORAGE HEIGHTS TO 18” BELOW FIRE SPRINKLER HEAD DEFLECTORS. 2. CONSTRUCTION TYPE: V-B NON-COMBUSTIBLE, UNOBSTRUCTED. 3. SPRINKLER SYSTEM DESIGNED, INSTALLED, BRACED AND TESTED PER NFPA-13 (2016). 4. ALL MATERIAL SHALL BE NEW AND U.L. LISTED AND F.M. APPROVED. 5. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, IT IS THE CONTRACTORS & OWNERS RESPONSIBILITY TO INSULATE WET SYSTEMS PROPERLY & TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVE CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 6. SPRINX FIRE PROTECTION SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. SPRINX FIRE PROTECTION STARTS AT A 6" FLANGE CONNECTION 1'-0" AFF. 7. ALL ELECTRICAL, PAINTING, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 8. PIPE SIZING PER NFPA-13, SYSTEM HYDRAULICALLY CALCULATED. 9. EARTHQUAKE BRACING PER NFPA-13 (2016) 10. ONLY NEW SPRINKLERS SHALL BE EMPLOYED IN THE INSTALLATION OF THE SPRINKLER SYSTEM. 11. A STOCK OF SPARE SPRINKLERS OF EACH STYLE, TYPE, AND TEMP. RATING ALONG WITH A SPRINKLER HEAD WRENCH SHALL BE LOCATED AT THE MAIN RISER. 12. ALL MAINS PIPING 21 2"- 4" IN SIZE TO BE BULL MOOSE TUBE EDDY FLOW THINWALL PIPE. ALL MAIN PIPING TO HAVE FIRELOCK GROOVED FITTINGS WITH WELDED OUTLETS 13. ALL LINE PIPING 1" - 1-1/4 " IN SIZE TO BE SCH-40, THREADED PIPE, WITH CAST OR DUCTILE IRON THREADED FITTINGS. GRID OR TREE LINE PIPING 1-1/2 " - 2" TO BE BULL MOOSE TUBE EDDY FLOW THINWALL PIPE. 14. LOWER FLOOR PIPE HANGERS TO BE HILTI KWIK CAST-IN ANCHORS KCS-WF, OR CEILING FLANGES IMBEDDED IN CONCRETE ROD AND RINGS. 15. UPPER FLOOR OR SINGLE STORY BUILDING HANGERS TO BE STEEL SAMMY SIDEWINDERS SWDR-1", ROD AND RINGS. (SEE HANGER DETAILS) 16. ALL PIPE DIMENSIONS ARE CENTER TO CENTER LENGTHS. 17. ALL ABOVE GROUND PIPING TO BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS. TESTING AND PIPE INSTALLATION INSPECTED BY LOCAL FIRE MARSHAL. 18. TOTAL AREA PROTECTED BY WET PIPE SYSTEM BUILDING "J" 14,850 SQ. FT. 19. OWNER TO MAINTAIN STORAGE TO A MINIMUM 18" BELOW FIRE SPRINKLER SYSTEM. OWNER TO INSTALL METAL BAFFLE IF SPRINKLERS ARE LESS THAN 6'-0" SPACES. OWNER TO ENSURE EXTRA HAZARD MATERIALS ARE NOT STORED IN FACILITY. 06/10/2024