Loading...
Yelm Boys & Girls SubmittalsProduct Data This unit has been designed utilizing Carrier’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information. Industry leading Features / Benefits Efficiency •13.8 - 16.5 SEER2 (14 - 18.0 SEER) / 11.2 – 14.0 EER2 (11.2 - 14.5 EER) •Microtube Technology refrigeration system •Indoor air quality accessories available Reliability •Puron refrigerant - environmentally sound, won’t deplete the ozone layer and low lifetime service cost. •Scroll compressor •Internal pressure relief valve •Internal thermal overload •Filter drier Durability WeatherArmor™ Ultra Protection Package: • Solid, Durable sheet metal construction •Steel louver coil guard •Baked-on, complete outer coverage, powder paint Applications •Long–line – up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more information.) •Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits. 24SPA6 Performance Series Single-Stage Air Conditioner with Puron® Refrigerant 1-1/2 To 5 Tons STANDARD FEATURES Features 18 24 30 36 42 43 48 49 60 61 Puron Refrigerant X X X X X X X X X X SEER2 (Range depending on indoor combination)14.3 - 16 14.3 - 16 14.3 - 16 14.3 - 16 13.8 - 15 14.3 - 16 13.8 - 15 14 - 16 13.8 - 15 14 - 16 Scroll Compressor X X X X X X X X X X Field Installed Filter Drier X X X X X X X X X X Front Seating Service Valves X X X X X X X X X X Internal Pressure Relief Valve X X X X X X X X X X Internal Thermal Overload X X X X X X X X X X Long Line Capability X X X X X X X X X X Low Ambient Capability with Kit X X X X X X X X X X High Pressure Switch X X X X X X X X X X Low Pressure Switch X X X X X X X X X X Compressor Sound Blanket X X X X X X X X X X Louvered Coil Guard X X X X X X X X X X 24SPA6: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 Model Number Nomenclature 1 2 3 4 5 6 7 8 9 10 11 12 N N A A A/N N N N A/N A/N A/N N 2 4 S P A 6 1 8 W 0 0 3 Product Series / Refrigerant Design Type Tier Major Series SEER2 Cooling Capacity Region Feature Special Feature Voltage 24 =AC w/ R-410A S = Single Stage P = Performance Series A=Initial 6 = 16 SEER2 1,000 Btuh (nominal) W = Standard SW AC 0=Standard 0=Standard 3=208/230-1 CATALOG ORDERING NUMBERS Size Model Number 18 24SPA618W003 24 24SPA624W003 30 24SPA630W003 36 24SPA636W003 42 24SPA642W003 43 24SPA643W003 48 24SPA648W003 49 24SPA649W003 60 24SPA660W003 61 24SPA6610W003 Physical Data Unit Size 18 24 30 36 42 43 48 49 60 61 Compressor Type Scroll REFRIGERANT Puron (R-410A) Control TXV (Puron Hard Shutoff) Factory Charge lb (kg)* *. For 15 ft. Line Set 4.70 (2.13)5.60 (2.54)6.60 (2.99)6.80 (3.08)8.10 (3.67)11.70 (5.31)8.10 (3.67)12.40 (5.62)10.10 (4.58)14.50 (6.58) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM)2050 2600 2575 3700 3890 3223 3890 4090 4260 4320 Motor HP 1/12 1/10 1/10 1/4 1/4 1/12 1/4 1/3 1/4 1/3 Motor RPM 1100 1100 1100 1100 1100 800 1100 800 1100 800 COND COIL Face Area (Sq ft)11.5 14.7 19.4 21.5 17.2 25.15 17.2 30.1 21.5 30.1 Fins per In.25 25 25 25 20 20 20 20 20 20 Rows 1 1 1 1 2 2 2 2 2 2 Circuits 3 4 5 6 8 8 8 10 9 12 VALVE CONNECT. (In. ID) Vapor 3/4 3/4 3/4 7/8 7/8 7/8”7/8 7/8 7/8 7/8 Liquid 3/8" REFRIGERANT TUBES* (In. OD) Rated Vapor† †.Units are rated with 25 ft. (7.6m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. 3/4 3/4 3/4 7/8 7/8 7/8”7/8 7/8 1 1/8 1 1/8 Rated Liquid Line‡ ‡.See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables 3/8" 24SPA6: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron® Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths : -- = outside acceptable range Table 1 – Maximum Total Equivalent Length* Outdoor Unit BELOW Indoor Unit *.Maximum actual length not to exceed 200 ft (61 m) Size Liquid Line Connection Liquid Line Diam. w/ TXV AC with Puron Refrigerant Maximum Total Equivalent Length†: Outdoor unit BELOW Indoor Vertical Separation ft (m) †.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. 0-5 (0-1.5) 6-10 (1.8-3.0) 11-20 (3.4-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-15.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 18 3/8 1/4 150 150 125 100 100 75 ------ 5/16 250*250*250*250*250*250*250*225*150 3/8 250*250*250*250*250*250*250*250*250* 24 3/8 1/4 75 75 75 50 50 -------- 5/16 250*250*250*250*250*225*175 125 100 3/8 250*250*250*250*250*250*250*250*250* 30 3/8 1/4 30 ---------------- 5/16 175 225*200 175 125 100 75 ---- 3/8 250*250*250*250*250*250*250*250*250* 36 3/8 5/16 175 150 150 100 100 100 75 ---- 3//8 250*250*250*250*250*250*250*250*250* 42, 43 3/8 5/16 125 100 100 75 75 50 ------ 3/8 250*250*250*250*250*250*250*250*150 48, 49 3/8 3/8 250*250*250*250*250*250*230 160 -- 60, 61 3/8 3/8 250*250*250*225*190 150 110 ---- Table 2 – Maximum* Total Equivalent Length Outdoor Unit ABOVE Indoor Unit *.Maximum actual length not to exceed 200 ft (61 m) Size Liquid Line Connection Liquid Line Diam. w/ TXV AC with Puron Refrigerant Maximum Total Equivalent Length†: Outdoor unit ABOVE Indoor Vertical Separation ft (m) †.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range 25 (7.6) 26-50 (7.9-15.2) 51-75 (15.5-22.9) 76-100 (23.2-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 18 3/8 1/4 175 250*250*250*250*250*250*250* 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 24 3/8 1/4 100 125 175 200 225*250*250*250* 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 30 3/8 1/4 30 -------------- 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 36 3/8 5/16 225*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 42, 43 3/8 5/16 175 200 250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 48, 49 3/8 3/8 250*250*250*250*250*250*250*250* 60, 61 3/8 3/8 250*250*250*250*250*250*250*250* 24SPA6: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft X total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of lineset* using existing 1/4“ liquid line. What charge adjustment is required? Formula:(.27 oz/ft X 15ft) – (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula:(.40 oz/ft. X 45ft) – (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27°C), and outdoor temperature must be 70°F to 100°F (21°C to 38°C). If outside these conditions, adjust charge for long linesets by weigh-in method. * When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information. Long Line Applications An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. Note: See Residential Piping and Long Line Guideline for details Table 3 – Refrigerant Charge Adjustments Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Table 4 – AC with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m)TXV required beyond 20 ft. (6.1 m) Table 5 – AC with Puron® Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 + TXV 120 (36.6)50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4)35 (10.7) vertical or 80 (24.4) total 80 (24.4) 24SPA6: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5 VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron® refrigerant: Table 6 – Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 1-Stage Air Conditioner Applications Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 1-Stage AC with Puron® 26-50 (7.9-15.2) 51-80 (15.5-24.4) 81-100 (24.7-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 201-225 (61.3-68.6) 226-250 (68.9-76.2) 18 3/8 1/2 1 2 3 5 6 7 8 9 11 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 24 3/8 5/8 0 1 2 2 3 3 4 5 5 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 30 3/8 5/8 1 2 3 3 4 5 6 7 8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 36 3/8 5/8 1 2 4 5 6 8 9 10 12 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 42, 43 3/8 3/4 0 1 2 2 3 4 4 5 6 7/8 0 0 1 1 1 2 2 2 3 1 1/8 0 0 0 0 0 0 0 0 0 48, 49 3/8 3/4 0 1 2 3 4 5 5 6 7 7/8 0 0 1 1 2 2 2 3 3 1 1/8 0 0 0 0 0 0 0 1 1 60, 61 3/8 3/4 1 2 4 5 6 7 9 10 11 7/8 0 1 2 2 3 4 4 5 5 1 1/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 24SPA6: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9 AHRI RATINGS For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here: www.MyCarrierRatings.com FLA- Full Load Amps LRA - Locked Rotor Amps MCA- Minimum Circuit Amps RLA- Rated Load Amps NOTE:Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with requirements of ASHRAE Standards 90.1 Short Circuit Current Rating (SCCR): 5kA rms NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Electrical Data UNIT SIZE V/PH OPER VOLTS* *.Permissible limits of the voltage range at which the unit will operate satisfactorily COMPR FAN MCA MAX FUSE† or CKT BRK AMPS †.Time-Delay fuse. MAX MIN LRA RLA FLA 18 208/230/1 253 197 42.6 8.8 0.4 11.4 20 24 59.5 10.9 0.6 14.2 20 30 71.3 11.7 0.6 15.2 25 36 80.1 12.2 1.4 16.7 25 42 120.0 25.0 1.52 32.8 50 43 109.0 16.7 0.50 21.4 35 48 120.0 25.0 1.52 32.8 50 49 124.0 18.5 2.80 25.9 40 60 150.0 25.6 1.40 33.4 50 61 140.6 26.3 2.80 35.7 50 A–Weighted Sound Power (dBA) UNIT SIZE STANDARD RATING TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 18 74 65.7 66.5 66.5 66.0 62.2 59.6 55.2 24 72 66.9 66.7 69.2 68.4 62.1 59.8 56.8 30 72 68.0 67.4 68.1 68.8 63.5 60.2 55.1 36 74 70.2 70.7 69.3 66.2 61.4 58.8 52.9 42 74 73.6 72.9 71.3 70.0 63.4 60.1 55.1 43 70 72.0 66.0 67.0 65.0 62.0 60.0 55.0 48 74 73.6 72.9 71.3 70.0 63.4 60.1 55.1 49 72 67.5 64.3 67.8 66.2 59.8 56.7 51.8 60 74 69.9 72.5 71.1 68.9 63.6 59.9 59.0 61 72 64.9 71.5 68.4 69.9 60.3 57.4 54.1 Charging Subcooling (TXV-Type Expansion Device) UNIT SIZE REQUIRED SUBCOOLING (°F)Indoor 18 7 TXV 24 9 30 10 36 8 42 10 43 12 48 10 49 8 60 14 61 9 24SPA6: Product DataManufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 DIMENSIONS Product Data A06009Fig. 1 – CAPMP The CAPMP evaporator coil incorporates proven standards for reliable system operation and performance throughout the life of this quality Air Conditioner or Heat Pump system. These quality evaporator coils, manufactured and installed as part of a total comfort system, provide AHRI-rated performance ratings and are additionally listed with UL and c-UL. This coil is available for use with R-410A Puron® Refrigerant only. It is a cased A-coil that is housed in a durable, 24-gauge, pre-painted taupe metallic cabinet. The fully insulated cabinet (foil faced with R-2.1 insulation properties) provides for quiet efficient operation of the evaporator coil. This multipoise coil offers the most in installation application flexibility; one coil for a variety of applications with fewer SKUs to stock. DESIGN FEATURES Performance Designed with performance in mind, this new A-coil offers low pressure drops to enhance system performance and airflow characteristics. Thermostatic Expansion Valves (TXV) All coils have refrigerant-specific, factory-installed TXVs. Durable Condensate Pans (2) The corrosion-resistant drain pans, one for vertical applications and one for horizontal, are designed in a “fiberglass reinforced thermoset polyester” material (FRTP) that offers unsurpassed pan strength. It is engineered with proper slope in both pans to help ensure water drainage, improved moisture removal, and home comfort. Refrigerant Connections Provided with industry proven sweat connections for leak-free operation to maintain system reliability. The side mounting tubing to the coil slabs allows for easy cleaning/servicing of the coils, as well as easy access to the TXV. Burst Pressure Meets or exceeds burst pressure of 2100 psi, which is at least three to five times the pressure it would see in actual application. UV Knockouts This cased coil comes with factory-installed UV knockouts for quick and easy installation of UV lights. Serviceability Comes with a “split delta plate” for easy, quick access to the coil for service and cleaning. Also, after the door is removed, the coil is removable from the front of the unit without use of any tools. CAPMP Evaporator Coil A Coil, Cased, Multipoise CAPMP: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 MODEL NUMBER NOMENCLATURE A221610 1 2 3 4 5 6 7 8 9 10 11 12 C A P M P 3 6 1 7 A L A Product VariationsC = Coil A = Basic Type Tubing Design L = AluminumA = A Coil Refrigerant Type P = Puron® Refrigerant (R-410A) TXV Revision LevelA = 1st Coil Configuration Cabinet Width 14 = 14-in (356 mm) 17 = 17-in (432 mm) 21 = 21-in (536 mm) 24 = 24-in (610 mm) M = Multipoise Cabinet FinishP = Painted Unit Capacity19 = 1 1/2 Ton 24 = 2 Ton 25 = 2 Ton 30 = 2-1/2 Ton 36 = 3 Ton 37 = 3 Ton 42 = 3-1/2 Ton 43 = 3-1/2 Ton 48 = 4 Ton 60 = 5 Ton 61 = 5 Ton Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. REGISTERED ISO 9001:2000 CAPMP: Product DataManufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 DIMENSIONS (1 of 2) A190313 Product Data A11263Representative drawing only. Some product models may vary. The 59SC6A Multipoise Comfort™Condensing Gas Furnace features year-round electrical efficiency when paired with a compatible condensing unit. Energy efficiency is at the heart of this furnace with up to 97.0% AFUE, gas efficiency and the electrically-efficient fixed-speeds, constant torque (MCT) ECM blower motor. Improved serviceability with the 3 digit status display and NFC enabled board allowing setup via the service tech app. This gas furnace also features 4-way multipoise installation flexibility, and is available in eleven model sizes. All sizes except the 26,000 BTUh model can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. The 26,000 BTUh model can use the same 2-pipe venting system using outside air for combustion, but is not considered direct-vent. All sizes are design certified in Canada, and select sizes are certified for mobile/manufactured home use with conversion kit accessory. PERFORMANCE • Multi 18-speed, constant torque (MCT) ECM blower motor for electrically efficient operation all year long in heating, cooling and continuous fan operation. • Enhanced diagnostics with easy to read 3-digit display for faults and status. • Single-speed inducer motor, and single-stage gas valve. • Silicon Nitride PowerHeat ™ Hot Surface Igniter. • Dual fuel capable HybridHeat ™ with a compatible heat pump and thermostat for energy-saving heating performance • Adjustable blower speed for heating and cooling. • Aluminized-steel primary heat exchanger. • Stainless-steel condensing secondary heat exchanger. INSTALLATION FLEXIBILITY • On-board NFC antenna makes setup a tap away when using the Carrier service technician app. • 4-way multipoise design for upflow, downflow or horizontal installation, with unique vent elbow for optional venting through-the-cabinet downflow venting capability. • Factory-configured ready for upflow applications. • Ideal height 35” (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. • Two-pipe venting, single-pipe venting or ventilated combustion air. APPLICATIONS • Approved for Twinning applications with manufacturer’s approved accessory kit. • Approved for Manufactured Housing/Mobile Home applications with MH accessory kit. • Convertible to propane with gas conversion accessory kit. CERTIFICATIONS • All sizes meet ENERGY STAR ® Version 4.1 criteria for gas furnaces: 95%+ AFUE. • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193. • All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirements. • A200351 59SC6A Comfort™ 96, Single-Stage, Multi 18-Speed ECM, Condensing Gas Furnace WARNING! CARBON MONOXIDE POISONING AND FIRE HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. This furnace is not designed for use in recreation vehicles or outdoors. This furnace is designed for use in manufactured (Mobile) homes when an optional Mobile Home accessory kit is installed. Failure to follow this warning could result in personal injury, death, and/or property damage. 59SC6A: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 A210796 Dimensional Drawing Dimensions FURNACE SIZE A B C D SHIP WT. LB (KG)CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 026M14--10 14-3/16 (361) 12-1/2 (319)12-9/16 (322)7-1/8 (181)119 (54) 040M14--10 14-3/16 (361) 12-1/2 (319)12-9/16 (322)7-1/8 (181)123 (56) 040M17--12 17-1/2 (445)15-7/8 (403)16 (406)8-3/4 (222)130 (59) 060M14--12 14-3/16 (361) 12-1/2 (319)12-9/16 (322)7-1/8 (181)129 (59) 060M17--16 17-1/2 (445)15-7/8 (403)16 (406)8-3/4 (222)142 (64) 080M17--16 17-1/2 (445)15-7/8 (403)16 (406)8-3/4 (222)150 (68) 080M21--20 21 (533)19-3/8 (492)19-1/2 (495)10-1/2 (267)158 (72) 100M21--20 21 (533)19-3/8 (492)19-1/2 (495)10-1/2 (267)167 (76) 100M21--22 21 (533)19-3/8 (492)19-1/2 (495)10-1/2 (267)167 (76) 120M24--22 24-1/2 (622)22-7/8 (581)23 (584)12-1/4 (311)181 (82) 140M24--22 24-1/2 (622)22-7/8 (581)23 (584)12-1/4 (311)189 (86) 59SC6A: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 MODEL NUMBER NOMENCLATURE A220581 FURNACE COMPONENTS A190145For California Residents: If installed with a manufactured (mobile) home conversion kit in SCAQMD: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size capacity increments. None of the furnace model sizes can be used if the heating load is 12,000 BTUh or lower. Use Air Conditioning Contractors of America (Manual J and S); American Society of Heating, Refrigerating, and Air-Conditioning Engineers; or other approved engineering method to calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely, customer discomfort and/or vent freezing. Failure to follow these guidelines is considered faulty installation and/or misapplication of the furnace; and resulting failure, damage, or repairs may impact warranty coverage. 1, 2 Gas Furnace 59 3 Heating Stages M 4 Tier N 5 Min. AFUE/NOx 7 6 Major Series B 7, 8, 9 Heating Input 060 10 Motor Type E 11, 12 Width 17 13 Voltage (1-phase) 1 14 Minor Series 1 15, 16 Airflow 16 |||||| ||||| 58 = 80% Non-Condensing 59 = 90%+ Condensing M = Modulating T = Two Stage S = Single Stage C = Single Stage Communicating 1 2 3 --- 08 = 800 CFM 10 = 1000 CFM 12 =1200 CFM 14 = 1400 CFM 16 = 1600 CFM 20 = 2000 CFM 22 = 2200 CFM B = Base C = Comfort E = Export N = Infinity P = Performance U = Ultra Low Nox 0 = 80% 1 = 80% Low NOx (Not Ultra Low NOx) 2 = 92% 5 = 95% 6 = 96% 7 = 97% 8 = 98% 1 = 110V/60Hz 2 = 230V/50Hz C = Constant Airflow Variable- Speed (VCA) ECM V = Variable-Speed (VCT) PWM M = Multi 18-Speed Constant Torque (MCT) ECM 026 = 26,000 BTU 040 = 40,000 BTU 060 = 60,000 BTU --- 155 = 155,000 BTU A B C --- 14 - 14.2" 17 - 17.5" 21 - 21.0" 24 - 24.5" RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) GAS VALVE MAIN LIMIT SWITCH (BEHIND GAS VALVE) ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY) OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE). FURNACE CONTROL BOARD MANUAL RESET ROLLOUT SWITCH FLAME SENSOR MANUAL RESET ROLLOUT SWITCHGAS BURNER HOT SURFACE IGNITER INDUCER MOTOR ASSEMBLY BLOWER AND MOTOR BLOWER DOOR SAFETY SWITCH POSITION CLEARANCE REAR 0 FRONT (Combustion air openings in furnace and in structure)1 in. (25 mm) Required for service *24 in. (610 mm) *. Consult local building codes All Sides of Supply Plenum *1 in. (25 mm) Sides 0 Vent 0 Top of Furnace 1 in. (25 mm) 59SC6A: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 SPECIFICATIONS Unit Size 026M14--10 040M14--10 040M17--12 060M14--12 060M17--16 080M17--16 HEATING AND CAPACITY AND EFFICIENCY Input BTUh* *. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. 26,000 40,000 40,000 60,000 60,000 80,000 Output Capacity (BTUh)†) †. Capacity in accordance with U.S. Government DOE test procedures. 25,000 39,000 39,000 56,000 58,000 78,000 Certified Temperature Rise Range - °F (°C)25-55 (14-31) 40-70 (22-39) 40-70 (22-39) 35-65 (19-36) 40-70 (22-39) 40-70 (22-39) AFUE Upflow/Hz 96.0% 96.0% 96.7% 95.0% 97.0% 97.0% Downflow 95.0% 95.0% 95.0% 95.0% 95.0% 95.0% AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Static Pressure Heating 0.10 0.10 0.10 0.12 0.12 0.12 Cooling 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM @ Rated ESP (CFM)‡ ‡. Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. Heating 620 705 700 945 1030 1290 Cooling 175-970 155-1000 160-1075 200-1165 315-1580 370-1625 Direct Drive Motor HP 1/3 1/2 1/2 1/2 3/4 3/4 Motor Full Load Amps 4.4 6.3 6.7 6.3 8.8 9.2 Heating Blower Control (Htg OFF-Delay)Adjustable: 90, 120 (factory-set), 150, 180 seconds Cooling Blower Control (Clg OFF-Delay)Adjustable: 90 (factory-set), 5, 30 seconds Blower Wheel Diameter x Width - In. (mm)11x7 (279x178) 11x7 (279x178) 11x8 (279x203) 11x7 (279x178) 11x8 (279x203) 11x8 (279x203) Air Filtration System Field Supplied Filter Filter used for Certified Watt Data 325531-40** **. See Accessory List for part numbers available. ELECTRICAL DATA Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.2 7.0 7.4 7.1 10.1 10.0 Unit Ampacity 7.5 9.7 10.2 9.8 13.6 13.4 Maximum Wire Length (Measure 1 way in Ft/M)50/15.2 38/11.7 36/11.1 38/11.5 27/8.3 27/8.4 Minimum Wire Size AWG 14 14 14 14 14 14 Max. Fuse/Ckt Bk Size (Time-Delay Type Recommended) Amps 15 15 15 15 15 15 Transformer Capacity (24 VAC output)40VA External Control Power Available Heating 12VA Cooling 35VA GAS CONTROLS Burners 2 2 3 3 4 4 Gas Connection Size 1/2 in. NPT Gas Valve (Redundant)Mfr White Rodgers™ Min. inlet pressure (in.w.c.)4.5 (Natural Gas) Max. inlet pressure (in.w.c.)13.6 (Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 44 CONNECTIONS Communication System None Thermostat Connections G,C, W, Y, R Accessory Connections EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y)