Asbestos Building Survey
Report Date: July 30, 2024
Property Inspected: 604 Yelm Ave W
Yelm, WA 98597
Parcel Number: 21724141300
Report Commissioned by: Gudelio Jimenez Bonilla
8120 Bicentennial Loop S.E. #A
Olympia, WA 98503
Property Inspected and Report Created By:
Gary Randall
AHERA Certification 192669
Certification Good Through February 21, 2025
Table of Contents
604 Yelm Ave W
Yelm, WA 98597
Parcel# 21724141300
1.0 Scope of Work
2.0 Asbestos Containing Materials (ACM) Survey Summary
3.0 Assessment and Recommendations
4.0 Statement of Compliance
Appendix (A) Asbestos Sample Summary (Chain of Custody)
Appendix (B) Laboratory Analysis
Appendix (C) Drawings (Floor Plan & Sample Location Map)
Appendix (D) Certifications
1.0 Scope of Work
On July 25, 2024, Gary Randall, an accredited AHERA Building Inspector for EnviroTech Consulting
Services, LLC (ETCS), conducted an asbestos-containing materials survey of 604 Yelm Ave W, Yelm, WA
98597 Parcel# 21724141300.
This structure is a 2,028-square-foot, single-story commercial building. The last use of this structure was
for a dog groomer. The Thurston County Assessor lists the date of construction as 1950. The owner
requested this survey in preparation for demolition.
The exterior of this structure is sided with T1-11 wood panels and cedar shakes. The windows are vinyl,
aluminum, and wood framed. This structure has a gable over the main section, a flat roof over the
N.W. addition, and a sloped roof over the N.E. section. The gable and sloped roof are covered with
three-tab composite shingles. The flat roof is covered with rolled asphaltic roofing. The interior walls
are textured gypsum wallboard. The ceilings are a mix of textured gypsum wallboard and a drop-down
grid with acoustic ceiling panels. The floors are a mix of vinyl planks, sheet vinyl, and vinyl tiles. The
walls are insulated with non-suspect fiberglass, and the attic is insulated with non-suspect blown-in.
There were no suspect materials found in the crawlspace.
Samples were collected from all suspect building materials and were submitted for laboratory analysis.
The following suspect materials were investigated:
❖ Asbestos-Containing Building Materials
Field inspection, data collection, and report generation were based on the following Scope of Work:
❖ Perform a visual inspection of the subject property to identify and inventory all
accessible suspect asbestos-containing materials.
❖ Bulk sampling and analysis of identified suspect asbestos-containing materials.
❖ Provide quantity estimates of asbestos-containing materials.
❖ Provide a written report including sample descriptions, sample locations, and sample
location drawings.
The survey was intended to identify any possible asbestos-containing materials (ACM) that may be
disturbed during demolition, remodeling, or maintenance activities per 40 CFR 61 Subpart M and to
maintain compliance with WAC 296-62-07721 and current applicable Puget Sound Clean Air Agency
(PSCA) regulations. ETCS has made a best-effort attempt to identify materials that may be disturbed. In
addition, this asbestos survey meets the U.S. EPA's "Good Faith" asbestos inspection requirements.
Suspect (ACM) materials within the structure were identified and classified as either Surfacing
Materials, Thermal System Insulation, or Miscellaneous Materials.
❖ Surfacing Materials are those that are either spray-applied or troweled-on for acoustical,
decorative, or fireproofing purposes.
❖ Thermal System Insulation (TSI) is the insulation used to inhibit heat transfer or prevent
condensation on pipes, boilers, tanks, ducts, and other components.
❖ Miscellaneous Materials include all other materials not included in the above
categories, such as floor tiles, ceiling tile, roofing felt, cementitious materials,
wallboard systems, and products such as caulking, mastics, and putties.
Twenty-three (23) Miscellaneous and Surfacing Materials were collected and submitted for
laboratory analysis.
Limitations of the Assessment
This targeted assessment was limited to the referenced buildings and did not include areas beyond
their "footprint." As described in this report, this report's conclusions are professional opinions based
solely upon visual site observations and analytical data interpretation.
Typical construction techniques can render portions of the building inaccessible. As a result, additional
asbestos-containing building materials (ACBM) may be present in inaccessible areas (i.e., within wall
and ceiling cavities). Suspect ACBM within inaccessible areas should be presumed to contain asbestos
until characterized. The opinions presented herein apply to the site conditions existing at the time of
investigation and interpretation of current asbestos regulations. The recommendations provided may
not apply to future conditions that exist at the site mentioned above.
Survey Methodology
The supporting documentation provided within this survey report includes a material summary
table and appendices that include building drawings, lab analytical reports, the chain of custody
forms, and inspector certifications.
2.0 Asbestos Containing Materials (ACM) Summary
Bulk samples collected by ETCS were submitted to Washington Asbestos Testing LLC, 11200 Kirkland
Way #340A, Kirkland, WA 98033, for sample analysis using polarized light microscopy (PLM) with
dispersing staining in accordance with U.S. EPA method 600/R93- 166 as specified in 40 CFR Chapter I
(7-1-93 edition) Part 763, Subpart F, Appendix A, pages 499-504. Polarizing light microscopy quantifies
asbestos concentrations between 100% - 1% detection levels. Levels below 1% can be stated as None
Detected (N.D.).
For samples containing more than one separable layer of material, the report will include findings for
each layer (labeled 1 for layer one, 2 for layer two, etc.) and a total percentage for the entire sample.
The asbestos concentration is determined by visual estimation.
For those samples with asbestos concentrations between one and ten percent based on visual
estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61).
Point counting is a statistically more accurate means of quantification for samples with low
concentrations of asbestos. Point counting will only be performed at the owner's or owner's agent
request.
The following suspect materials were found to contain asbestos:
Asbestos Detected
604 Yelm Ave W
Yelm, WA 98597
Parcel# 21724141300
Sample # Collection
Location
Layer
#
Description of
Material
Type % ACM Type Total*
3 Room 6 Floor 5 Tan/Red Vinyl Miscellaneous 1.25%
Chrysotile
Non-Friable 42 SF
7 Room 2 W Wall 4 Tan compact powdery
texture with paint
Surfacing .75%
Chrysotile
Friable 483 SF
8 Room 2 S.W. Wall 2 Tan compact powdery
joint compound with
paper
Miscellaneous <1%
Chrysotile
Friable 48 SF
9 Room 2 Ceiling 3 Tan compact powdery
joint compound with
paper
Miscellaneous <1%
Chrysotile
Friable 30 SF
13 Room 6 Ceiling
Above D.D.
2 Tan compact powdery
texture with paint
Surfacing .25%
Chrysotile
Friable 42 SF
16 Room 9 N Wall 1 Tan compact powdery
joint compound with
paper
Miscellaneous <1%
Chrysotile
Friable 10 SF
*All measurements provided are approximations, and drawings are not too scale.
3.0 Assessment and Recommendations
Assessment
The ACM identified in the subject structure falls into the Miscellaneous and Surfacing categories. The
asbestos-containing building material (ACBM) found in this structure:
a. In room 6 (bathroom), the bottom layer of flooring is a tan/red vinyl tile. This floor is asbestos-
containing.
b. In rooms 2, 6, and 9, the wall and ceiling texture and joint compound contain trace amounts of
asbestos (less than 1% asbestos content).
Recommendations
Asbestos Material <1%
The asbestos-containing material in this structure that is <1% is not a regulated material and
does not require an abatement contractor for removal and disposal; however, Washington
State Labor and Industries have published rules for the safe removal of GWB that contain trace
amounts of asbestos in the joint compound and textures. Most requirements for <1% asbestos
work are found in WAC 296-62-07712(2,4 & 5), WAC 296-62-07722(5), and WAC 296-62-
07728. These materials may be left in place during demolition and disposed of as regular non-
asbestos building debris.
Asbestos Materials >1%
All material in this structure with an asbestos content >1% is regulated material and must be
abated before any demolition or remodeling activity that may disturb these materials at the
subject property. A Washington State Certified Abatement Contractor must conduct the
abatement of ACM. The owner or the owner's contractor must not disturb the ACM.
A copy of this report must be provided to any employee or contractor conducting renovation or
demolition activities at this structure.
Tr
a
c
e
A
m
o
u
n
t
s
4.0 Statement of Compliance
In accordance with WAC 296-62-07721 and current applicable PSCA regulations, EnviroTech Consulting Services
LLC performed an Asbestos Building Survey at 604 Yelm Ave W, Yelm, WA 98597, Parcel# 21724141300.
A Washington State Certified Asbestos Abatement Contractor must conduct the abatement of asbestos -
containing materials. Should employees or contract personnel encounter any suspect asbestos-containing
materials, it is their responsibility to:
1. Contact a representative of the owner.
2. Consult the inspection report to determine whether the suspect material contains asbestos.
3. Ensure that all employees and contractors are informed and advised of the location and type of
materials that contain asbestos.
The following asbestos-containing materials were identified at the subject property:
Asbestos Detected
604 Yelm Ave W
Yelm, WA 98597
Parcel# 21724141300
Sample # Collection
Location
Layer
#
Description of
Material
Type % ACM Type Total*
3 Room 6 Floor 5 Tan/Red Vinyl Miscellaneous 1.25%
Chrysotile
Non-Friable 42 SF
7 Room 2 W Wall 4 Tan compact powdery
texture with paint
Surfacing .75%
Chrysotile
Friable 483 SF
8 Room 2 S.W. Wall 2 Tan compact powdery
joint compound with
paper
Miscellaneous <1%
Chrysotile
Friable 48 SF
9 Room 2 Ceiling 3 Tan compact powdery
joint compound with
paper
Miscellaneous <1%
Chrysotile
Friable 30 SF
13 Room 6 Ceiling
Above D.D.
2 Tan compact powdery
texture with paint
Surfacing .25%
Chrysotile
Friable 42 SF
16 Room 9 N Wall 1 Tan compact powdery
joint compound with
paper
Miscellaneous <1%
Chrysotile
Friable 10 SF
*All measurements provided are approximations, and drawings are not too scale.
I Hereby Attest:
I have been given the inspection report. I will inform all subcontractors of the location and types of asbestos -
containing materials. I am authorized to sign on behalf of my company.
Contractor: Owner Rep:
Print Name: Print Name:
Signature: Signature: _
Title: Title:
Date: Date: _
Tr
a
c
e
A
m
o
u
n
t
s
Pictures
Room 6 (bathroom), the bottom layer of flooring is
asbestos-containing.
The wall and ceiling texture and joint compound in this
room contain trace amounts of asbestos (less than 1%).
The wall and ceiling texture and joint compound in this
room contain trace amounts of asbestos (less than 1%).
The wall and ceiling texture and joint compound in this
room contain trace amounts of asbestos (less than 1%).
The upper ceiling texture in room 6 (bathroom) contains
trace amounts of asbestos (less than 1%).
The wall joint compound in this room contains trace
amounts of asbestos (less than 1%).
VWAr
Batch# : AT U-q 013 97-
11200 Kirkland ►Nay #340A
Kirkland, WA 98033
(425) 65$ 7286
WATestingLLC.com
BULK ASBESTOS TEST X POINT COUNT (400/600/1000) TAPE LEAD MOLD
Client Name: EnviTaTecb Consulting Services,11C
Address: P.Q. Box 65R City. Aberdeen ST: WA ZIP: 99524
Phone #, (360) 533-8117
Project Manager: Crary Randall Email: results(oenvirotechcs.com
Project Location/jots Name: Bonilla - Parcel #21724141300
Address: 604 Yelm Ave W City: Yelm
SAMPLES: Turn Around Time: Z Day Humber of samples:
Condition: Good Damaged Severe Damage
ST: WA Zip: 98503
23
SELF
Sample Location
Sample Description
SEQ#
Sample Location
Sample Description
1
Room 1 Floor
Blk VCT WlMastic
26
2
Room 9 Floor
Core 13rn SV & Wht SV
27
3
Room 6 Floor
Core Bru VCT & Blk Asphaltic
28
4
Room 18 Wall
GWID WITex, 7C
29
5 JRoom
1 Ceiling
GWB Wtfex 7C
30
6
Room 1 E Wall
GW13 Wlrex, JC
31
7
Room 2 W Wall
GWB WtTex, JC
32
8
Room 2 SW Walt
GWR W/3C
33
9
Room 2 Ceiling
W]"ex,
GWB Tex, ]C
34
10
Room 7 S Wall
GWB W/Tex, ]C
35
11
Room 7 Ceiling
GWB W[rex, JC
36
12
Room 7 N Wall
GWB W/Tex, JC
37
13
Rooin 6 Ceiling Above DD
GWB W/Tex, X
38
14
Room 6 Ceiling
Acoustic Ceiling Pane]
39
15
Room 6 S Ws31
GVM WITex, JC
40
16
Room 9 N Wail
GWB Wlrex,1C
41
17
Room 2 S Wall
Cove Base WBra Mastic
42
18
lRoom I S Wall
Blk Cove Base W/Mastic
43
19
Room 2 NW Window
Wht Putty Material
44
20
Room 8 Fireplaoc
WhtMortar
45
21
Roof Chimney
CuyMortar
46
22
Roof Room 7
Core Rolled Asphaltic Matoxial
47
23
Roof Room 12
Care 3-Tab Asphatic W/Tar Papt
48
24
49
25
50
Print Name
IPA
Company Name
Date
Time
sampled
Gary Randall
ETCS
7/24/2024
11:30 AM
Relinquished
Gary Randall
t
ETCS
7/24/2024
3:45 PM
Delivered
UPS
UPS
Received
WAT
Analyzed
WELT
=yp
Reported
C r
WATy
-- U
How would you litre to be notified? Email x Phone
Washington Asbestos Testing LLC guarantees the test results provided are of a precision normal with the type of methods recognized In asbestos
analysis. Washington Asbestos Testing LLC accepts no legal responsihnity for the purpose for which the client uses the test results, by signing on this
Chain of Custody form the dient agrees to retieve Washington Asbestos Testing LLC of arty and all iiablity that may afrse from the lest results.
MWWashington Asbestos Testing LLC • watestingllc.com Amendment to Report, Batch #: WATT2402367
11200 Kirkland Way Ste- 340A, Kirkland, WA 98033 • (425) 658-7286
12811 Sth Ave W Ste. B101, Everett, WA 98204 • (425) 374-8706
15 S Oregon Ave Ste 204 T tomW NVLAP Lab Code 600040-a
. , a ., A 98409 • V53) 301-1852
Asbestos Analysis of Bulk Materials by App. E to Sub. E of 40 CFR Part 763 and EPA 600/R-93/116
Methods Using Polarized Light Microscopy
Attn: Gary Randall Office Phone: (360) 533-8117
EnviroTech Consulting Services, LLC Date Received: 7j25�2g24
PO BOX658, Aberdeen, WA 98520 Date Analyzed: 7/25/2024
Project: Bonilla- Parcel Samples Received: 23 #2i72414130U Samples Analyzed: 23
604 Yelm Ave W, Yelm, WA, 98503 Date of Revision: 7/30/2024
Analyzed By
Sydney Borg Approved By
A
SEQ# SAMPLE M LAYER
1
2
1 Room 1 Floor
3
4
1
2
2 1 Room 9 Floor
3 1 Room 6 Floor
4 1 Room 1 S Wall
DESCRIPTION
Gray vinyl covering
Black vinyl tile
Clear mastic
Gray sandy brittle material
Brown sheet vinyl
Yellow mastic
3 Brown wood
4 W h ite vinyl tile
5 Yellow mastic
6 Brown wood
7 Beige sheet vinyl
8 Black asphaltic fibrous material
9
Gray mastic
10
Brown wood debris
1
White vinyl covering
2
Gray vinyl tile
3
Clear mastic
4
Brown wood
5
Tan/Red vinyl
6 Black asphaltic fibrous material
1 White compact powdery material with
woven mesh and paint
2 White �halhy material with paper
pproved Signatoryllf Neressary}
95 NON -ASBESTOS FIBERS % NON -FIBROUS *A ASBESTOS TYPE
None Detected 100% Non -fibrous
None Detected
2% Cellulose
2% Cellulose
2% Cellulose
None Detected
2% Cellulose
5% Cellulose
2% Cellulose
2% Cellulose
5% Cellulose
None Detected
70% Cellulose
ZVQ Cellulose
2% Cellulose
None Detected
2% Cellulose
2% Cellulose
5% Cellulose
2% Cellulose
70% Cellulose
25% Glass, Cellulose
20% Cellulose
98% Non -fibrous
(Other)
98% Non -fibrous
(Other)
9$1/. Non -fibrous
(Other)
100% Non -fibrous
(Other)
98% Non -fibrous
(Other)
95% Non-flbrou5
(Other)
98% Non -fibrous
(Other)
98% Non -fibrous
(Other)
95% Non -fibrous
(Other)
100% Non -fibrous
(Other)
30% Non -fibrous
(Other)
98% Nan -fibrous
(Other)
98% Non -fibrous
(Other)
100% Non -fibrous
(other)
98% Non -fibrous
(Other)
,as% Non -fibrous
(Other)
95% Non -fibrous
(Other)
95% Nan -fibrous
(Other)
30% Nan -fibrous
(ather)
75Y. Non -fibrous
(Other)
80% Non -fibrous
(Other)
None Detected
None Detected
{None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
2% Chrysetile
None Detected
None Detected
None Detected
The results given relate only to the items tested- The results apply to the sample(r) as recelved.
Reports must not be used by the client to claim product certification, approval, or endorsement by NVLAP, MIST, Or any agency of the Federal Government.
Page 1 of 4
Asbestos Testing LLC • watestfngllc.com Amendment to Report, Batch #: WATT2402367
11291) Kirkland Way Ste. 340A, Kirkland, WA 98033 • (425)659-7286
WATWashington
128118th Ave W Ste. 6101, Everett, WA 99204 • (425)374-8706
15 5Oregon Ave Ste. 204, Tacoma, WA 98409 (253) 301-1852
NV LAP Lab Code 500044 0
Asbestos Analysis of Bulk Materials by App. E to Sub. E of 40 CFR Part 763 and EPA 600/R-93/116
Methods Using Polarized Light Microscopy
Attn: Gary Randall
EnviroTech Consulting Services, LLC
Office Phone.
(360) 533-8117
PO BOX 659, Aberdeen, WA 98520
Date Received:
7/25/2024
Date Analyzed:
7/25/2024
j arojert: Bonilla- parcel #21724141300
Samples Received:
23
�04Yelm Ave W, Yelm, WA, 98503
Samples Analyzed:
23
Date of Revision:
7/30/2024
Analyzed B Approved By
Sydney Borg
Slgnatary [if Ne[essary}
DESCRIPTION
SPQ# SAMPLE ID LAYER nESCRlPTION % NON -ASBESTOS FIBERS
% NON -FIBROUS
% A58ESTOS TYPE
1 White cum pact powdery material with
woven mesh and paint ZS%b Glass, Cellulose
5 Room 1 Ceiling
Non -fibrous
75% }
(Other)
None Detected
2 White chalky material with paper 20% Cellulose
80% Non -fibrous
{therj
None Detected
1 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
6 Roam 1 E Wall
{ether}
None Detected
2 White chalky material with paper 20% Cellulose
Non -Fibrous
80%
None Detected
(Other)
1 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
{Other}
None Detected
2 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
(other)
None Detected
7 Roam 2 W Wall 3 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
(other)
None Detected
4 -fan compact powdery texture with paint 3% Cellulose
Non -fibrous
95%
21A Chrysotile
(Other)
5 White chalky material with paper 20% Cellulose
80Y. Non -fibrous
None Detected
(Other)
1 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
None Detected
(other]
Room 2 SW Wall 2 Tan compact powdery joint compound with
Nan -fibrous
35% Cellulose
g paper
63°�
{Qtherj
2°5 Chrysotile
3 White chalky material with paper 20% Cellulose
Non -fibrous
Sfl%
None Detected
Composite Result
(other]
4 Brawn wood with paint 5% Cellulose
a1%
95%, Non -fibrous
None Detected
(Other)
1 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
(Other)
None Detected
Room 2 Ceiling 2 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
!Other)
None Detected
3 Tan compact powdery joint compound with
Non -fibrous
355'o Cellulose
paper
63%
(Other)
2% Chrysotile
Composite Result
c1% 4 White chalky material with paper 20% Cellulose
Non -fibrous
80%
None Detetted
(Other)
1 White compact powdery texture with paint 3% Cellulose
47% Non -fibrous
None Detected
(Other)
10 Room 7 S Waif 2 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
lather}
None Detected
3 White chalky material with paper 20% Cellulose
80%, Non -fibrous
None Detected
(Other)
1 White compact powdery texture with paint 3% Cellulose
97% Non -fibrous
None Detected
(Other)
11 Room 7 Ceiling 2 White compact powdery joint Compound
35% Cellulose
Non -fibrous
With paper
55%
(Other)
None Detected
3 White tha* material with paper 24% Cellulose
801% Nan -fibrous
None Detected
(Other)
The results given relate only to the items tested. The results apply to the sample(s) as received.
Reports must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Page 2 of 4
Washington Asbestos Testing LLC • watestinglic.com Amendment to ReportBatch #:
11200 Kirkland • [425] fi58-728fi
way Ste. 340A, Kirkland, WA 98033 WAiTZ402367
128118th Ave W Ste. B101, Everett, WA 98204 • (425) 374-8706
VW15 S Oregon Ave Ste. 204, Tacoma, WA 98409 NV LAP, Lab Code 504040-0
• [253] 3Q1-18S�
Asbestos Analysis of Bulk Materials by App. E to Sub. E of 40 CFR Part 763 and EPA 600/R-93/116
Methods Using polarized Light Microscopy
Attn: Gary Randall
EriviroTech Consulting Services, LLC
PO BOX 658, Aberdeen, WA 98520
Project: Bonilla- Parcel #21724141300
lm Ave W, Yelm, WA, 98503
Analyzed
Sydney Borg
sEng SAI ,
Office Phone: (360) 533-8117
Date Received: 7/25/2024
Date Analyzed: 7/25/2024
Samples Received: 23
Samples Analyzed: 23
Date of Revision: 7/30/2024
Approved By
Approved Signatory {If Necessary}
E ID
iArER
DESCRIPTION
%
NON A58fSTOS FIBERS
%
NON -FIBROUS
% ASBESTOS TYPE
1
White compact powdery texture with paint
3%
Cellulose
9796
Non -fibrous
12
Room 7 N Wail
{other]
None Detected
2
White chalky material with paper
20%
Cellulose
80%
Non -fibrous
{Other}
None detected
1
White compact powdery texture with paint
3%
Cellulose
97%
Non -fibrous
[Other)
None Detected
ROO11 6 Ceiling
2
Tan compact powdery texture with paint
3%
Cellulose
953
Non -Fibrous
Z%
13
Above €]p
{Other]
Chrysotile
3
White chalky material with paper
20%
Cellulose
80%
Non -fibrous
IO(her)
None Detected
4
Gray fibrous insulation
8S%
Cellulose
15%
Nan -fibrous
(Other]
None Detected
14
Room 6 Ceiling
1
Gray fibrous material with paint, glass beads,
Non -fibrous
and perlite
65%
Celfulose, Glass
35%
(Other)
None Detected
15
Room 6 5 Wail
1
Brown chalky material with paper and paint
20%
Cellulose
80%
Non -fibrous
[Other}
None Detected
Room 9 N Wall
1
Tan compact powdery }pint Compound with
Non -fibrous
ib
paint and paper
35�k
Cellulose
63Yo
{Other]
2% Chrysotile
Composite Result
c1%
2
White chafky materiai with paper
20%
Celluose
80%
Nan -fibrous
IOther)
None Detected
1
Yellow mastic
2%
Cellulose
48%
Non -Fibrous
17
Room 2 5 Wail
(Other)
None Detected
2
8rown paper with paint
75%
Cellulose
25%
Non -fibrous
None Detected
{ether]
1
Biack rubbery material
2%
Cellulose
98%
Non -fibrous
(Other)
None Detected
18
Room 15 Wall
2
Yellow mastic
2%
Cellulose
984'
Non -fibrous
I ther]
None Detected
3
White compact powdery texture with paint
3%
Cellulose
97%
Non -fibrous
(Other)
None Detected
19
R4om 2 NW
Window
1
Gray brittle material with paint
2%
Cellulose
98%
Nan -fibrous
(other)
None Detected
1
White ceramic
None Detected
100%
Non -fibrous
None Detected
(Other)
20
Room 8 Fireplace
2
Tan mastic
2%
Ceflulose
98%
Non -fibrous
(Other)
None Detected
3
Brown wood debris
5%
Cellulose
95%
Non -fibrous
None Detected
{ether)
21
Roof Chimney
1
Pink sand brittle material
YI
2%
Cellulose
Nan -fibrous
98%
1-1—
None Detected
The results given relate only to the items tested. The results apply to the sample(s) as received,
Reports must not be used by the Ghent to claim product certification, approval, or endorsement by NVLAP, NISI, or any agency of the Federal Government.
page 3 of 4
Asbestos Testing LLC • watestingllc.com Amendment to Report, Batch it:
11200 Kirkland Way Ste, 340A, Kirkland, WA 98033 • (425)658-7286
WATWashington
WATT2442367
12811 Sth Ave W Ste. 13101, Everett, WA 98204 • (425)374-8706
15 5 Oregon Ave Ste. 204, Tacoma, WA 98409 • [253] 301-1852
NV LAP Lab Code G00040-0
Asbestos Analysis of Bulk Materials by App. E to Sub. E
of 40 CFR Part 763 and
EPA 600/R-931116
Methods Using Polarized Light Microscopy
Attn: Gary Randall — —
FnviroTech Consulting Services, LLC
Office Phone:
(360) 533-8117
PO BOX 658, Aberdeen, WA 98520
pate Received:
7/25/2024
Rate Analyzed:
7/25/2024
Project. Bonilla- Parcel #21724141300
Samples Received:
23
504 Yelm Aveamples
W, Yelm, WA, 9$503
Analyzed:
23e
Date of Revision:
7/30/2024
Analyzed
Approved by
Sydney Borg
Approved Signatory (if Necessary)
5@Q# SAMPLE 1D LAYER DESCRIPTION % NON -ASBESTOS FIBERS
% NON -FIBROUS
% ASBESTOSTVPE
1
Black asphaltic material 3% Cellulose
97% Non fibrous
{Other}
None Detected
2
Black asphaltic material with sand 25% Glass
75% Non -fibrous
{Qtherj
None Detected
3
Black asphaltic material 3% Cellulose
97% Non -fibrous
None Detected
{Other}
22
Roof Room 7
4
Black asphaltic material with sand 25% Glass
75% Non -fibrous
(Other)
None Detected
5
Black asphaltic material 3% Cellulose
97% Non -fibrous
(other)
None Detected
6
Black asphaltic fibrous material 70% Cellulase
30% Non -fibrous
(Other)
None Detected
7
Brown woad debris 5% Cellulose
95% Nan -Fibrous
None Detected
{Other}
1
Black asphaltic material with sand 25% Glass
75% Non -fibrous
(Other]
None Detected
2
Black asphaltic material 3% Cellulose
97% Non -fibrous
{Other]
None Detected
3
Black asphaltic materlaI with sand 25% Glass
75� Non -fibrous
(Other)
None Detected
23
Roof Room 12
4
Black asphaltic material 3% Cellulose
97% Nan -fibrous
10therj
None Detected
5
Black asphaltic material with sand 25% Glass
75% Non Fibrous
None Detected
(Other)
6
Black asphaltic material 3% Cel{u105e
97% Non fibrous
None Detected
[other}
7
Black asphaltic fibrous material 70% Cellulose
30% Non -fibrous
{other]
Nane Detected
8
grown wood debris 5% Cellulose
95% Non -fibrous
None Detected
{Other}
Note: The following amendments were made to this report: Point count analysis was done on samples #3,7 and 13's wall textures. As
texture, joint compound and wallboards were composited due to client's reauest.
welt as samples
#8,9 and 15's wall
The results given relate onIy to the items tested. The results apply to the sampte(s) as received.
Reports must not be used by the client to claim product certification, approval, or endorsement by NVLAP. NIST, or any agency of the Federal Government,
Page 4 of 4
WATWashington ASbestos Testing LLC vntestingllc.com Batch m WATT2402417
11200 KirWand Way Ste. 340A, Kirkland, WA 98033 . (425)658-7286
129118th Ave W Ste, B101, Everett, WA 98204 • (425) 374-8706
1S 5 Oregon Ave Ste. 204, Tacoma, WA 98409 NVLAP Lab Code 600040-0
�r1�a.u. %ww I ° (253j 301-1852
Asbestos Analysis of Bulk Materials by App. E to Sub. E of 40 CFR Part 763 and EPA 500/11-93/116 Methods Using
Polarized Light Microscopy
400 Point Count Method Performed Using PLM Cross Polar Red I Compensator 20X
Attn, Gary Randall
EnviriaTech Consulting Services, LLC
PO BOX 658, Aberdeen, WA 93520
Project: Bonilla- Parcel #217Z4141300
604 Yelm Ave W, Yelm, WA, 9$S03
Analyzed By
Sydney Borg
Original Batch#:
WATT2402367
Original SEQ#
3
Sample ID:
Room 6 Floor
Layer to be Counted:
5
Sample Description:
Tan/Red Vinyl
Original Asbestos Result: Positive 21Y.
Asbestos Type;
Chrysotile
Originally Analyzed by:
Sydney Borg
Approved By
Office Phone: {360y 533-8117
Date Received: 7/30/2024
Date Analyzed: 7/30/2024
Approved 5lgna tory (If NeCeSsaryI
Slide #
Asbestos Points
Non -Asbestos Points
Total Points Counted
Slide 1
1
49
50
Slide 2
0
50
5o
Slide 3
0
so
50
Slide 4
0
50
50
Slide 5
1
49
SD
Slide 6
0
50
50
Slide 7
2
48 1
50
Slide 8
1
49
50
Total I
5
395
400
Point Count Result. -
Percentage of Asbestos: 115%
The results given relate only to the items tested. The results apply to the samples} as received.
Reports must not be used by the client to claim Product certification, approval, or endorsement by NVLAP, MIST, or any agency of the Federal Government.
Iof3
Washington Asbestos Testing LLC • watestingllc,com
wA 11200 Kirkland Way Ste. 340A, rrrkland, WA 98033 • (425)658-7286Satch #: WATT2402437
12811 8th Ave W Ste. BI01, Everett, WA 98204 • (425)374-870615 S Ore on Ave Ste, 204, Tacoma, WA 98409 NVIAF Lab Cflde 60g040 fl
�u= 6 ° (253j 301-1$52
Asbestos Analysis of Bulk Materials by App. E to Sub. E of 40 CFR Part 763 and EPA 600/R-93/116 Methods Using
Polarized Light Microscopy
400 Point Count Method Performed Using PLM Cross Polar Red I Compensator 20X
Attu: Gary Randall
EnviroTech Consulting Services, LLC
PO BOX 653, Aberdeen, WA 98520
Project: Bonilla- Parcel #21724141300
_604 Yalm Ave W, Yelm, WA, 99503
Analyzed By
Sydney Borg
Original Batch#: WA1724172367
Original SEg# 7
Sample ID: Room 2 W Wall
Layer to be Counted: 4
Sample Description: Tan compact powdery texture with paint
Original Asbestos Result: Positive 2%
Asbestos Type: Chrysotile
Originally Analyzed by: Sydney Borg
Point Count Result:
Percentage of Asbestos: 0.75%
Office Phone: (360) 533-8117
Date Received: 713012024
Date Analyzed: 7/30/2024
Approved By
Approved Signatory (it Necessary}
The results given relate only to the items tested. The results apply to the sample(s) as received.
Reports must not he used by the client to claim product certification, approval, or endorsement by NVLAP, MIST, or any agency of the Federal Government.
2of3
Washington Asbestos Testing PLC a watestingllc.coyn Batch #: WATT2402417
A 11200 Kirkland Way Ste, 340A, Kirkland, WA 98033 . (425) 6S8.7285
128118th Ave W Ste, 6101, Everett, WA 98204 A (425) 374-8705
15 S Oregon Ave Ste. 204, Tacoma, WA 98409 NVLAP Lab Code 6i7(]046-p
+►w-*�k+.a. v�us ° (253} 301-1552
Asbestos Analysis of Bulk Materials by App. E to Sub. E of 40 CFR Part 763 and EPA 600/R-93/116 Methods Using
Polarized Light Microscopy
400 Point Count Method Performed Using PLM Cross Polar fled I Compensator 20X
Attn: Gary Randall
EnviroTech Consulting services, LLC
PO BOX 658, Aberdeen, WA 98520
Project: Bonilia- Parcel #21724141300
6 44 Yelm Ave W, Yelm, WA, 98503
Analyzed By
Sydney Borg
Original Batch#:
Original SEQ#
Sample ID:
Layer to be Counted:
WATT2402367
13
Room 6 Ceiling Above DD
2
Sample Description: Tan compact powdery texture with paint
Original Asbestos Result: Positive 2%
Asbestos Type: Chrysotile
Originally Analyzed by: Sydney Borg
Approved ay
Office Phone: (360) 533-8117
Date Received: 7/30/2024
Date Analyzed_ 7/30/2024
Approved Signatory (If Necessary)
Slide #
Asbestos Points
Non -Asbestos Points
Total Points Counted
Slide 1
❑
50
50
Slide 2
0
50
50
Slide 3
0
50
50
Slide 4
1
49
so
Slide 5
❑
50
S0
Slide 6
0
5o
so
Slide 7
❑
50
50
Slide 8
0
50
so
Total
1
399
400
Point Count Result:
Percentage of Asbestos: 0.25%
The results given relate only to the items tested. The results apply to the sarnple(s) as received.
Reports must not be used by the client to claim product certification, approval, or Endorsement by NVLAP, N15T, or any agency of the Federal Government.
3of3
Site:
604 Yelm Ave West, Yelm, WA 98503
Owner:
Bonilla
Project Name:
Bonilla
EnviroTech Consulting Services, LLC
P.O. Box 658
Aberdeen, WA 98520
(360) 533-8117
EnviroTechCS.com
Title:
Appendix C
Sample Collection Map
Scale:
Not To Scale
Date:
7/24/2024
Rev:
A
N
Yelm Ave West
Asbestos Containing Material (> 1%)
Trace Amounts of
Asbestos Found (<1%)
No Asbestos Detected
Room 1
Room 2
Room 3
Room 4
Room 5
Room 6
Room 7
Room 8
Room 9
Room 10
Room 11
Room 12
1
11
13
14
9
10
12
16
15
20
21
5
19
22
23
4
2
3
6
7
8
17
18
Fe�l - ? �01 I - em � � X&& � � A71h V?-
NOW Environmental Services
Of Federal Way. Washington certifies to all that
Gary Randall
From November 15`° -November 171i. 2023 has fulfilled the requirements of
AHERA PROJECT DESIGNER
Ilan attended and satisfactorily completed the requirements to be accredited as an
Asbestos Abatement Project Designer in accordance with the -toxic Substance Control Act Tnle (Section 206)
and 40 CPR 763 An requirements m the accreditation as an Asbesms Abatement Project Designer in accordance with the
ACCREDITATION NO. VD-NEs-i 1-17-23-n2
ExpiCah- November 17i - 2024
Mike Lawrence - Instructor
Certificate of Completion
This is to certify that
Gary A. Randall
has satisfactorily completed
4 hours of online refresher training as an
AHERA Building Inspector
to comply with the training requirements of
TSCA Title II, 40 CFR 763 (AHERA)
EPA Provider # 1085
192669
AY I Certificate Number
1/ ' ' ` Feb 21, 2024 Expires in 1
Instructor: Sue Maas Dates) of Training
Exam Score: N/A
j -Foci urios (if applicable)
lkierracon - E°. m°mo°t
• Go�[ce led c.l
STATE OF WASHINGTON
Department of Commerce
Lead -Based Paint Activities Program
Gary Allen Randall
Has fulfilled the certification requirements of
WAC 365-230
and has been certified to conduct lead based
paint activities as a
Risk Assessor.
Certlfleatlon # LwaoeeDate Fri
8906 071`1712M 071172 6
United States Department of Commerce
National Institute of Standards and Technology
Certificate of Accreditation to ISOMEC 17025:2017
NNZ AP LAB CODE: 600040-0
Washington Asbestos Testing LLC
Kirk -land, WA
is accredited by the National Voluntary Laboratory Accreditation Program for specific services.
listed on the Scope of Accreditation. for. -
Asbestos Fiber Analysis
This laboratory is accredited in accordance with the recognized International Standard ISOREC 17025:2017.
This accreditation demonstrates technical competence fora defined scope and the operation of a laboratory quality
management system (refer to joint !SO-ILAC-IAF Communique dated January 2009),
o g 4 f 9
2023-10-01through2024-09-30 4` `��_ - '�i,,V �
Effective Dates Far fhe National Vofurxaiy Laboratory Accreditation Program
o p
STATES OF