2021 WSEC_Lighting calculations
2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2024 NEEA, All rights reserved Project & Applicant Information Project Title Yelm Community Schools Transportation TI - 2021 WSEC For Building Department Use: I Date: Aug 09, 2024 Project Address 202 NW Stevens Ave. Yelm, WA 98597 Applicant Name Jane Locke Applicant Phone 360-339-8274 Applicant Email jane@tovanihart.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Office, Other Building Cond. Floor 14,510 Type Area Project Cond. Floor 14,510 Alteration New Building or Alteration Interior Lighting Area Floors Above Grade 1 General Project Types Change in Space Conditioning (Semi -heated converted to Fully Addition Lighting Scope Exterior Compliance Method General Conditioned) Lighting Scope Lighting Prescriptive Lighting Project Description Conversion of a warehouse space to restrooms and a driver meeting room - new lighting and controlled receptacles in the meeting room. Lighting Compliance Project Type Interior / Exterior (Interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification Scope & parking) J and Method Alteration Interior Lighting 20% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Alteration Exterior Lighting less than 20% replaced Not applicable to exterior COMPLIES Additional Energy Efficiency (AEC) Reduced lighting power density - 10% lower than LPA Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Measures Included roject Title Yelm Community Schools Transportation TI - 2021 WSEC , Lighting Power Calculation ALTERATION -INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Corridors General 441 0.41 181 Lounge/breakroom General 2,085 0.59 1,230 Restroom General 550 0.63 347 Proposed Total LPD 784 Totals 1 1 1,757 784 COMPLIES Proposed Lighting Power Density Fixture Type 7Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Direct / indirect pendant 4 28 112 Troffer RL2 20 32 630 Recessed downlight RLl 2 21 42 Proposed Total LPD 784 Project Title Yelm Community Schools Transportation TI - 2021 WSEC Date Aug 09, 2024 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (20% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Direct / indirect pendant PL1 E2.01 LLD New Fixture Description: PENDANT LINEAR Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Troffer RL2 I E2.01 LED New Fixture Description: LED flat panel Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Recessed downlight RL1 I E2.01 LED New Fixture Description: Downlight Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title Yelm Community Schools Transportation TI - 2021 WSEC Aug 09, 2024 Lighting Power Calculation ALTERATION - EXTERIOR LIGHTING (less than 20% replaced) Compliance Verification I COMPLIES Exterior Lighting Power Allowance Category Existing Lighting -Wattage Prior to Alteration Total Watts Allowed Proposed Total LPD Compliance Status Existing Lighting 100 1 100 1 50 COMPLIES Proposed Exterior Lighting Power Density Quantity of Watts per Total Watts Fixture Type Fixture ID New or Existing -to -Remain Fixtures CLDs or Fixture, CLD or Total Linear Feet (LF) Watts per Linear Foot (WpLF) Proposed (#F x WpF) or Luminaires (#F) Luminaire (WpF) (LF x WpLF) Individual Fixtures Wall -mounted WLl New 2 25 50 Yelm Community Schools Transportation TI - 2021 WSEC Date Aug 09, 7Fixtures Propoetails ALTERATION -EXTERIOR LIGHTING (less than 20% replaced)Fication Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individ Wall-mounted WLl E2.01 LED New Fixture Description: Wall Mount Do these fixtures require specific exterior lighting controls?: Daylight sensing off controls