Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
24-052 Eagle Plaza - Shell Building Equipment Sub 8-12
KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DR. SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 LICENSE NO. KNIGHFP044LK Fire Sprinkler System Equipment Submittal Eagle Plaza – Shell Bldg. 937 Yelm Ave. Yelm, WA 98597 KFP Job #24-052 KFP Job #12-113 F1FR80 Series Sprinklers Summary Sprinkler Model K-Factor gpm/psi1/2 (lpm/bar1/2) Max. Working Pressure psi (bar)Listings & Approvals Orientation Sprinkler Identification Number (SIN) F1FR80 8.0 (115) 175 (12) 250 (17) (cULus only) cULus, FM, LPCB, VdS, CE, UKCA Upright RA6322 Pendent RA6312 Table A Model F1FR80 Upright Sprinkler Model F1FR80 Pendent Sprinkler Note: Not all versions of the product are shown. Features • Standard coverage quick-response sprinklers • Upright and pendent orientations • Low profile, compact design • Available in a wide variety of finishes • Available as Intermediate Level sprinklers Product Description Reliable Model F1FR80 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3mm glass bulb thermal element. Pendent sprinklers may be installed exposed, or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed, the Model F1FR80 series sprinklers are specifically listed with and may only be installed with listed Reliable recessed escutcheons. Refer to the technical information on the following pages for specific listings for recessed installations and refer to Figure 3 for dimensional information. When fitted with an approved Reliable water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. www.reliablesprinkler.com K-factor 8.0 (115) F1FR80 Series Quick-Response Sprinklers Bulletin 063 January 2023 Model F1FR80 Upright Sprinkler SIN RA6322 Technical Specifications Style: Upright Threads: 3/4” NPT or ISO 7-R3/4 Nominal K-Factor: 8.0 (115) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields F-1 Guard (cULus, FM) F-2 Guard (FM) F-3 Guard with Shield (cULus, FM) Sprinkler Wrenches Model W2 Model J (with guard installed) Listings and Approvals cULus FM LPCB VdS CE UKCA: 0832-UKCA-CPR-S5078 Model F1FR80 Upright Sprinkler Components and Dimensions Figure 1 Bulletin 063 January 2023 Page 2 of 6 www.reliablesprinkler.com Deflector Glass Bulb (3 mm) Wrench Flat Threads 1 3/8" [33mm] 3 1/4" [83mm] Cap/Seal Assembly Load Screw 2 1/2" [62mm] F1FR_THREE QTR_UPR_INT Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Installation Model F1FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N.m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Maintenance Reliable Model F1FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Wrenches Model W2 (upright, pendent) Model J (with guard installed) Model W4 (recessed pendent) Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons Sprinkler F1, F2 and FP(2) Escutcheons Bronze Brass Electroless Nickel PTFE(3)(4)Bright Brass Chrome Plated Chrome Plated Bright Brass(5)Satin Chrome White Polyester(3)White Polyester Satin Chrome Custom Color Polyester Custom Color Polyester(3)(6) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons utilizes a galvanized steel cup with a finished trim ring. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. 6. cULus Only. Finishes(1)Table B Bulletin 063 January 2023 Page 5 of 6 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 5 0 3 Bulletin 063 January 2023 Page 6 of 6 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR80 Deflector/Orientation • Upright • Upright Intermediate • Pendent Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon • F1 • F2 • FP Escutcheon Finish • See Table B Sprinkler Wrench • Model W2 (upright and pendent) • Model W4 (recessed) • Model J (with guard installed) Sprinkler Model Max. Working Pressure psi (bar) Maximum Coverage Area Width x Length ft x ft (m x m) Flow Rate gpm (L/min) Pressure psi (bar) Sprinkler Identification Number (SIN) DH56 Dry EC 250 (17.2) 28 x 8 (8.5 x 2.4)23 (87.1)16.9 (1.2) RA1664 28 x 10 (8.5 x 3)28 (106)25 (1.7) Table A DH56 Dry EC HSW with standard escutcheon Features • Coverage for long and narrow light hazard spaces such as hallways, decks, and rooms • Coverage area up to 28 ft (8.5m) long and 10 ft (3m) deep • Available in four trim styles and a variety of finish combina- tions. Product Description The Reliable Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler is a quick-response sprinkler utilizing a sensitive 3mm glass bulb thermal element listed for use in light hazard applications. Dry sprinklers are intended for use on wet, dry, and preaction systems to protect indoor and outdoor areas that are subject to freezing. When used on wet systems, it is important that a minimum exposed length of barrel inside the face of the wall or insulation is provided to offset conduction of potentially freezing temperatures from the unconditioned (sprinkler) end along the barrel. See Figure 6 for guidelines on using dry sprinklers on wet systems. Environments where dry sprinklers are employed are often corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax prevents contaminants from entering the internal portion of the drop nipple and must not be removed. www.reliablesprinkler.com Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in accordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8.5m) wide and 10 feet (3m) deep. Model DH56 sprinklers are rated for 250 psi (17.2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. cULus Listed Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Bulletin 016 April 2023 Model DH56 EC HSW Coverage Area Figure 1 Model DH56 EC Horizontal Sidewall Sprinkler SIN RA1664 Technical Specifications Style: Extended Coverage Horizontal Sidewall Threads: 1” NPT or ISO7-1R1 Nominal K-Factor: 5.6 (80) Max. Working Pressure: 250 psi (17.2 bar) Max. Spacing: 28 ft (8.5m) Min. Spacing: 16 ft (4.9m) Material Specifications Inlet Fitting: Brass Alloy Flip Disk: Brass Alloy Seal: PTFE Coated Belleville Spring Outer Tube: Galvanized Steel Pipe Sprinkler Frame: Brass Alloy Bulb Insert: Copper Alloy Thermal Element: Glass Bulb Deflector: Bronze Alloy Load Screw: Brass Alloy Sprinkler Finishes See finish combination tables on following pages Sensitivity Quick Response Temperature Ratings 155°F (68°C) 175°F (79°C) 200°F (93°C) Recessed Escutcheons/Cover Plates Standard Escutcheon HB Escutcheon FP Escutcheon SWC Cover Plate Listings and Approvals cULus Listed for Light Hazard 28' [8.5m] Maximum Spacing 16' [4.9m] Minimum Spacing MODEL DH56 DRY SPRINKLER 4" [100mm] Min. from Ceiling 12" [300mm] Max. from Ceiling Wall Floor Coverage Area DH56DRYCOVAREA 28' [8.5m] 8' [2.4m] or 10' [3m] Based on Selected Discharge Flow and Pressure Shown here with standard escutcheon. See pages 3-6 for additional trim styles Bulletin 016 April 2023 Page 2 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with Standard Escutcheon Figure 2 System Tee 3" Dia. [76mm] Nominal Position of Escutcheon Wa l l Inlet Fitting 1" [25mm] Escutcheon Adjustment 1-15/16"" [53mm] Ceiling "A" Dimension 1/2" [12mm] Escutcheon Adjustment Sprinkler Can 2-1/8" Dia. [54mm] Hole in Wall016STD-A 4" [100mm] Min. 12" [300mm] Max. DH56 DRY HSW SPRINKLER, STANDARD ESCUTCHEON 1/2" [12mm] Nominal Protrusion 5/8" [16mm] 1/2" [12mm] "A" Dimension = 2" to 48" (50mm to 1200mm) Finish Combinations: Standard Escutcheon Sprinkler Escutcheon(2)(3) Bronze Polished Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)Polished Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel. “A” Dimension: 2” to 48” (50mm to 1200mm) in 1/4” (6mm) increments Bulletin 016 April 2023 Page 3 of 10 www.reliablesprinkler.com “A” Dimension: 3-1/2” to 36” (90mm to 900mm) in 1/4” (6mm) increments Bulletin 016 April 2023 Page 4 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with HB Escutcheon Figure 3 System Tee 3-1/2" [89 mm] Dia. Nominal Escutcheon Position 1/2" [13 mm] Escutcheon Adjustment "A" Dimension 2 1/2" Dia. [64 mm] Hole in Wall 1/2" [13 mm] Escutcheon Adjustment 1-15/16"" [49mm] 5/8" [16 mm] Sprinkler Can Inlet Fitting Escutcheon 1-1/4" [32mm] Nominal Projection 1-1/4" [32mm] Wa l l Ceiling 016HB Finish Combinations: HB Escutcheon Sprinkler Escutcheon(2)(3) Bronze Chrome Chrome Chrome White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. “A” Dimension: 3-1/2” to 48” (90mm to1200mm) in 1/4” (6mm) increments Bulletin 016 April 2023 Page 5 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with FP Escutcheon Figure 4 Hole in Wall 3-1/4" [82mm] 2 5/8" Dia. [67mm] "A" Dimension System Tee Wa l l 4" [102mm] Min. 12" [305mm] Max. Ceiling Sprinkler Cup Escutcheon Inlet Fitting 1/4" [6mm] 1/4" [6mm] Escutcheon Adjustment Escutcheon Adjustment 1 1/4" [32mm] Nom Nominal Position of Escutcheon 5/8" [16mm] 016FP Finish Combinations: FP Recessed Escutcheon Sprinkler(1)Escutcheon(3)(4) Bronze Brass Chrome Chrome White Polyester(2)White Polyester Black Polyester(2)Black Polyester Custom Color Polyester(2)Custom Color Polyester Electroless Nickel PTFE(2)Stainless Steel Notes: 1. Cup for FP Recessed is unfinished galvanized steel except electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Note: Do not install the Model DH56 Dry Sprinkler with FP recessed escutcheon in locations where the pressure in the space behind the sprinkler is positive with respect to the pressure in the protected space. Ensure that openings in the sprinkler cup are unobstructed following installation. “A” Dimension: 3-1/2” to 48” (90mm to1200mm) in 1/4” (6mm) increments Bulletin 016 April 2023 Page 6 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with SWC Cover Plate Figure 5 4" [102mm] Min 12" [305mm] Max "A" Dimension 1/4" [6mm] Cover Plate Adjustment 1/4" [6mm] Cover Plate Adjustment Nominal Position of Cover Plate System Tee Inlet Fitting 5/8" [16mm] 1-9/16" [40mm] 2-5/8" [67mm] Dia. Hole in Wall 3-7/32" Dia. [82mm] Sprinkler Cup 016SWC Wa l l Ceiling Finish Combinations: SWC Concealed Cover Plate Sprinkler(1)Cover Plate(2) Bronze White Polyester Chrome Bright Chrome Dull Bright Brass Unfinished Bronze Custom Color Notes: 1. Cup for SWC Concealed is unfinished galvanized steel. 2. Cover plates do not carry corrosion resistant listings. Note: Do not install the Model DH56 Dry Sprinkler with SWC cover plate in locations where the pressure in the space behind the sprinkler is positive with respect to the pressure in the protected space. Ensure that openings in the sprinkler cup are unobstructed following installation. Bulletin 016 April 2023 Page 7 of 10 www.reliablesprinkler.com Figure 6 Bulletin 016 April 2023 Page 8 of 10 www.reliablesprinkler.com Figure 7 Installation (General) Dry sprinklers connected to wet pipe systems must be installed as indicated in Figure 6 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. Reliable Model DH56 dry sidewall sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 7). DO NOT install Reliable Model DH56 dry sidewall sprinklers into elbows or couplings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. DH56 HSW with Standard Escutcheon Cut a 2-1/8” (54mm) diameter hole in the wall as shown in Fig. 2. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the escutcheon over the finished sleeve until tight to the finished surface. DH56 HSW with HB Escutcheon Cut a 2-1/2” (64mm) diameter hole in the wall as shown in Fig. 3. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the skirt over the finished sleeve until tight to the finished suface. DH56 HSW with FP Recessed Escutcheon Cut a 2-5/8” (67mm) diameter hole in the wall as shown in Fig. 4. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the FP escutcheon into the threaded cup. Final adjustment is made by turning the FP escutcheon clockwise until the flange makes full contact with the wall surface. DH56 HSW SWC Concealed Cover Plate Cut a 2-5/8” (67mm) diameter hole in the wall as shown in Fig. 5. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the SWC cover plate into the threaded cup. Final adjustment is made by turning the cover plate clockwise until the cover plate flange makes full contact with the finished surface. Note: 1. The Model XLO2 installation wrench for FP Recessed and SWC Concealed installations has a open side to accommodate the sprinkler deflector and can only be inserted in one way (see Figure 8). Care must be taken not to damage the deflector during installation. 2. Do not over-tighten sprinklers into fittings. It is recommended that Reliable dry sprinklers be installed using the wrench referenced in this bulletin. A pipe wrench may also be used to install dry sprinklers provided that it only engages the outer tube (steel pipe) of the assembly. Note that a pipe wrench will impart a large amount of torque into the final assembly. This torque will need to be matched or exceeded to remove the sprinkler at a later date. A leak free joint can normally be obtained by installing the sprinkler to a minimum torque of 22 ft-lb (30 N-m) after applying an appropriate thread sealant. 3. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. Reliable installation wrenches are designed to install sprinklers while bulb protectors are in place. REMOVE THE PROTECTORS AT THE TIME THE SPRINKLER SYSTEM IS PLACED INTO SERVICE. Removal of the protectors before this time may leave the glass bulb vulnerable to damage. Remove protectors by undoing the clasp by hand. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 4. Do not remove the wax fillet in the gap between the cup that supports the bulb and the wrenching boss. Step 3 Step 2 Step 1 Figure 8XLO2 Installation Procedure Bulletin 016 April 2023 Page 9 of 10 www.reliablesprinkler.com Maintenance Reliable Model DH56 series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents US Patent No. 7,841,418 Wrench Options F3R Wrench (Standard & HB trims)XLO2 Wrench (FP recessed and SWC trims) Ordering Information Specify: Sprinkler Type • Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Trim Style • Standard Escutcheon • HB Escutcheon • FP Recessed Esctucheon • SWC Cover Plate Temperature Rating • 155°F (68°C) • 175°F (79°C) • 200°F (93°C) Finish • See available combinations (depending on trim style) on pages 3-6 Length • “A” Dimension (face of fitting to finished wall surface, in 1/4” [6mm] increments) Installation Wrench • Model F3R (Standard & HB trims) • Model XLO2 (FP Recessed & SWC trims) Bulletin 016 April 2023 Page 10 of 10 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 3 0 8 victaulic.com 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 1.0 PRODUCT DESCRIPTION • Available Sizes: 2 – 12"/50 – 300 mm • cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. • Designed for fire protection services only. • Features a weatherproof actuator housing Approved for indoor and outdoor use. • Actuation options: Hand wheel (2 – 12”/50 – 300 mm) • Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS G410013 LPS 1185: Issue 3.1 Cert/LPCB Ref. 104j/01 846a/01 FireLock ® Butterfly Valve Series 705 with Weatherproof Actuator 10.81 1 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2 50 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 2 ½ 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4 100 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6 150 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS – MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 – 6”/50 – 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 – 12”/200 – 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade “E” EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 2 – 8"/50 – 200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing 10 – 12"/250 – 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 2 victaulic.com 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Series 705 F G E A D ØH B C J Size Dimensions Nominal Actual Outside Diameter E to E A B C D E F G DIA H J inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm 2 2.375 4.25 2.28 6.41 ––4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 2 ½2.875 3.77 2.28 7.54 ––4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 76.1 mm 3.000 3.77 2.28 7.54 ––4.00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 ––4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 ––5.50 4.22 4.50 2.20 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 ––5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 ––6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 139.7 mm 5.500 5.88 3.35 10.88 ––6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 ––6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 159 mm 6.250 5.88 3.84 11.38 –0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1mm 6.500 5.88 3.84 11.38 –0.41 7.52 6.19 6.30 2.58 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 –0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 –273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 –323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 NOTE • Optional ½"/15 mm tap available. Contact Victaulic for details. 3 victaulic.com 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Size Outside Diameter Equivalent mm inches mm inches Feet/m of pipe 2 2.375 6 50 60.3 1.8 2 ½2.875 6 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 4 victaulic.com 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE Series 705 CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for Cv values Formulas for Kv values P = Q 2 Cv 2 Q = Cv x P Where: Q = Flow (GPM) P = P ressure Drop (psi) Cv = Flow Coecient P = Q 2 Cv 2 Q = Cv x P Where: Q = Flow (GPM) P = P ressure Drop (psi) Cv = Flow Coecient Q = Flow (m3/hr) P = Pressure Drop (Bar) Kv = Flow Coecient Where: Q = Flow (m3/hr) P = Pressure Drop (Bar) Kv = Flow Coecient Where: Valve Size Full Open Valve Size Full Open Nominal Size Actual Outside Diameter Flow Coefficient Nominal Size Actual Outside Diameter Flow Coefficient inches mm inches mm Cv inches mm inches mm Kv 2 2.375 170 2 2.375 1475060.3 50 60.3 2 ½2.875 260 2 ½2.875 2256573.0 65 73.0 76.1 mm 3.000 260 76.1 mm 3.000 22576.1 76.1 3 3.500 440 3 3.500 3808088.9 80 88.9 4 4.500 820 4 4.500 710100114.3 100 114.3 108 mm 108 mm 820 108 mm 108 mm 710 5 5.563 1200 5 5.563 1040125141.3 125 141.3 133 mm 133 mm 1200 133 mm 133 mm 1040 139.7 mm 5.500 1200 139.7 mm 5.500 1040139.7 139.7 6 6.625 1800 6 6.625 1560150168.3 150 168.3 159 mm 159 mm 1800 159 mm 159 mm 1560 165.1 mm 6.500 1800 165.1 mm 6.500 1560165.1 165.1 8 8.625 3400 8 8.625 2940200219.1 200 219.1 10 10.750 5800 10 10.750 5020250273.0 250 273.0 12 12.750 9000 12 12.750 7790300323.9 300 323.9 5 victaulic.com 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring 1. The supervisory switch contains two single pole, double throw, pre-wired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the “OPEN” position. 5. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 6. A #14 insulated ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S1 {Normally Closed: (2) Blue Common: (2) Yellow S2 {Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe NOTES • The above diagram shows a connection between the common terminal (yellow – S1 and yellow-with-orange stripe – S2) and the normally closed terminal (blue – S1 and blue-with-orange stripe – S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). • Only S1 (two leads per terminal) may be connected to the fire alarm control panel. • The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). CONDUIT ½" NPT CONDUIT CONNECTORS UL LISTEDJUNCTION BOX WIRE NUTS FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT N.C.NO.COM. TO END-OF-LINE RESISTOR, OR NEXT INDICATOR BELL OR HORNVOLTAGE SOURCE Switch 1: 2 leads per terminal Switch 2: 1 lead per terminal SWITCH CONTACT RATING: 10A AT 125 AND 250VAC, 0.5A AT 125 VDC, 0.25 AT 250 VDC S1 S2 6 victaulic.com 10.81 5662 Rev L Updated 08/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty I-100: Field Installation Handbook 7 victaulic.com victaulic.com 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series 717 (2½ − 3"/65 − 80 mm) Series 717 (4 − 12"/100 − 300 mm) Series 717H High Pressure Check Valve (2 – 3"/50 – 80 mm) 1.0 PRODUCT DESCRIPTION Available Sizes • 2 – 3"/DN50 – DN80 (Series 717H) • 2 ½ – 12"/DN50 – DN300 (Series 717) Pressure Class • Up to 365 psi/2517 kPa/25 bar • Working pressure dependent on size of pipe, valve size and approval requirements. Application • Designed for use in Fire Protection systems. • Prevents back flow. • Single-disc mechanism incorporates a spring-assisted feature for non-slamming operation. • Can be installed either vertically (flow upwards only) or horizontally. • Valve body cast with arrow indicator to assist with proper valve orientation. • Optional upstream and downstream pressure taps included on select sizes. See Section 3.0. • Provided with grooved ends. • Rated for ambient temperature use in fire protection systems. 2.0 CERTIFICATION/LISTINGS NOTE • Refer to Victaulic submittal publication 10.01 for details FireLock ® Check Valves Series 717 Check Valve Series 717H High Pressure Check Valve 10.08 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 2.0 CERTIFICATION/LISTINGS (C ontinued) Approvals/Listings Size Approval/Listing Service Pressures Series 717H cULus FM LPCB Vds 2"/50 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 2 ½"/65 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 76.1 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 3"/80 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa Approval/Listing Service Pressures Series 717 Size cULus FM LPCB Vds 2 ½"/65 mm 250 psi/1725 kPa n/a 365 psi/2517 kPa n/a 76.1 mm 250 psi/1725 kPa n/a 365 psi/2517 kPa 16bar/232 psi 3"/80 mm 250 psi/1725 kPa n/a 365 psi/2517 kPa 16bar/232 psi 4"/100 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 16bar/232 psi 5"/125 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa n/a 139.7 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 16bar/232 psi 6"/150 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 16bar/232 psi 165.1 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa n/a 8"/200 mm 365 psi/2517 kPa 365 psi/2517 kPa 348 psi/2400 kPa 16bar/232 psi 10"/250 mm 250 psi/1725 kPa 250 psi/1725 kPa 1725 kPa/250 psi n/a 12"/300 mm 250 psi/1725 kPa 250 psi/1725 kPa 1725 kPa/250 psi n/a 2 victaulic.com 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 3.0 SPECIFICATIONS – MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12. Body Coating: Series 717H Body: Black Paint Series 717H Endface: Electroless Nickel conforming to ASTM B-733 Series 717 (2 ½ – 3"/DN65 – DN80): PPS Coating Series 717 (4 – 12"/DN100 – DN300): Black Paint Body Seat: Series 717H: Nitrile O-ring installed into an Electroless Nickel plating conforming to ASTM B-733 Series 717 (2 ½” – 3”/DN65 – DN80): PPS Coated Ductile Iron S eries 717 (4 – 12”/DN100 – DN300): Ductile Iron with Electroless Nickel plating conforming to ASTM B-733 Disc Seal or Coating: (specify choice1) Nitrile (Series 717H only) EPDM NOT COMPATIBLE FOR PETROLEUM SERVICES. Discs: Series 717H: CF8M Cast Stainless Steel Series 717 (2 ½ – 3"/DN65 – DN80): Aluminum bronze with elastomer seal S eries 717 (4 – 12"/DN100 – DN300): Elastomer encapsulated disc. Shaft: Series 717H: Brass Series 717 (2 ½ – 3"/DN65 – DN80): Type 416 Stainless Steel Series 717 (4 – 12"/DN100 – DN300): Type 316 Stainless Steel Spring: Type 302/304 Stainless Steel Shaft Plug: Series 717H: Carbon Steel Zinc Plated Series 717: Carbon Steel Zinc Plated Pipe Plug: Series 717H: Carbon Steel Zinc Plated Series 717: Carbon Steel Zinc Plated Optional Pressure Taps: Series 717H: Available on all sizes Series 717: Available on sizes 4 – 12"/DN100 – DN300 3 victaulic.com 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Series 717 C A B 1J 2K B 2 1 3 ½" NPT Upstream Drain ½" NPT Downstream Drain 2" NPT (Drain Optional) R A 3 C ED P A C ED J 2 1 P B K 1 2 ½" NPT Upstream Drain ½" NPT Downstream Drain Typical 2 ½ – 3"/65 – 80 mm Typical 4 – 8"/100 – 200 mm Typical 10 – 12"/250 – 300 mm Size Dimensions Weight Nominal inches mm Actual Outside Diameter inches mm E to E A inches mm B inches mm C inches mm D inches mm E inches mm J inches mm K inches mm P inches mm R inches mm Approximate (Each) lb kg 2 ½2.875 3.88 4.26 3.57 ––––––3.6 65 73.0 99 108 91 1.6 76.1 mm 3.000 76.1 3.88 99 4.26 108 3.57 91 ––––––3.6 1.6 3 3.500 4.25 5.06 4.17 ––––––4.5 80 88.9 108 129 106 2.0 4 100 4.500 114.3 9.63 245 6.00 152 3.88 99 2.75 70 3.50 89 2.00 51 4.50 114 3.50 89 3.35 85 20.0 9.1 5 5.563 10.50 6.80 4.50 –4.17 2.15 5.88 4.08 3.98 27.0 125 141.3 267 173 114 106 55 149 104 101 12.3 139.7 mm 5.500 139.7 10.50 267 6.80 173 4.50 114 –4.17 106 2.15 55 5.88 149 4.08 104 3.98 101 27.0 12.3 6 6.625 11.50 8.00 5.00 –4.50 2.38 6.67 4.73 3.89 38.0 150 168.3 292 203 127 114 61 169 120 99 17.2 165.1 mm 6.500 165.1 11.50 292 8.00 203 5.00 127 –4.50 114 2.38 61 6.67 169 4.73 120 3.89 99 38.0 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 250 10.750 273.0 17.00 432 12.00 305 7.09 180 5.96 151 6.69 170 2.15 55 10.92 277 6.73 171 –100.0 45.4 12 12.750 19.50 14.00 8.06 6.91 7.64 2.51 12.81 7.73 –140.0 300 323.9 495 356 205 176 194 64 925 196 63.5 4 victaulic.com 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Flow Characteristics The charts below express the flow of water at 60ºF/16ºC through valve. S717H / 717HR 2"/5 0 m m 2½"/ 6 5 m m & 7 6 . 1 m m 3"/80 m m 0.1 1 10 10 100 1000 Flow Rate – GPM Pr e s s u r e L o s s – p s i S717H / 717HR 1.00 10.00 100.00 100 1000 10000 2½"/6 5 m m & 7 6 . 1 m m 3"/80 m m2"/50 mm Flow Rate – Litres/Min. Pr e s s u r e L o s s – k P a 6 victaulic.com 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE Flow Characteristics The charts below express the flow of water at 60ºF/16ºC through valve. S717 / 717R 0.1 1 10 10 100 1000 10000 100000 Flow Rate – GPM Pr e s s u r e L o s s – p s i 2½" / 6 5 m m & 7 6 . 1 m m 5"/1 2 5 m m & 1 3 9 . 7 m m 3"/ 8 0 m m 4"/1 0 0 m m 8"/ 2 0 0 m m 6"/1 5 0 m m & 1 6 5 . 1 m m 10" / 2 5 0 m m 12"/ 3 0 0 m m S717 / 717R 2½ " / 6 5 m m & 7 6 . 1 m m 5"/1 2 5 m m & 1 3 9 . 7 m m 3"/ 8 0 m m 4"/1 0 0 m m 8"/ 2 0 0 m m 6"/1 5 0 m m & 1 6 5 . 1 m m 10" / 2 5 0 m m 12"/ 3 0 0 m m 1.00 10.00 100.00 10 100 1000 10000 100000 Pr e s s u r e L o s s – k P a Flow Rate – Litres/Min. 7 victaulic.com 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, as well as Victaulic performance, maintenance, Victaulic reserves the right to change product specifications, designs and standard safety, and warning instructions. Nothing in this or any other document, nor any verbal equipment without notice and without incurring obligations. recommendation, advice, or opinion from any Victaulic employee, shall be deemed to Installationalter, vary, supersede, or waive any provision of Victaulic Company's standard conditions Reference should always be made to the Victaulic installation handbook or installation of sale, installation guide, or this disclaimer.instructions of the product you are installing. Handbooks are included with each shipment Intellectual Property Rights of Victaulic products, providing complete installation and assembly data, and are available No statement contained herein concerning a possible or suggested use of any material, in PDF format on our website at www.victaulic.com. product, service, or design is intended, or should be constructed, to grant any license Warrantyunder any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details.or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual Trademarks property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic and all other Victaulic marks are the trademarks or registered trademarks of or patent applications for articles and/or methods of use in the United States and/or other Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. countries. 6.0 NOTIFICATIONS WARNING • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. 7.0 REFERENCE MATERIALS 05.01: Seal Selection Guide 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty I-100: Field Installation Handbook 8 victaulic.com Se i s m i c B r a c i n g Seismic Bracing All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 66 B-Line series Fire Protection SolutionsEaton Size Range: Pipe size to be braced: 1" (25mm) thru 8" (200mm) IPS. Pipe size used for bracing: 1" (25mm) and 11⁄4" (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedule 7 through schedule 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). UL Listed for the following sprinkler type pipes: Sch. 40 (and as brace member), Sch. 10, Bull Moose Eddy Flow, Wheatland Mega Flow, DIN 2448, KSD 3562 (and as brace member), KSD 3507. Ask the factory for additional information as it may vary by product size. Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. For FM Approval information refer to FM Approved page 67. Finish: Plain, Electro-Galvanized or Hot Dip Galvanized. Contact customer service for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11⁄4" (32mm)), and finish. TOLCO Fig. 1001 - sway brace attachment (UL listed) Set Bolts Included Pipe Part Number & Approx. Wt./100 Design Load - Lbs. Size 1" (25mm) Brace Pipe 11/4" (32mm) Brace Pipe For Brace Pipe Size 1" / 11/4" Sch. 7 Sch. 10 Sch. 40 in. (mm) Lbs. (kg) Lbs. (kg) 1" / 11/4" 1" / 11/4" 1" / 11/4" 1" (25) 1001-1 X 1 104.6 (47.4) 1001-1 X 11/4 122.2 (55.4) — / — — / — 1000 / 1000 11/4" (32) 1001-11/4 X 1 105.2 (47.7) 1001-11/4 X 11/4 122.6 (55.6) 1000 / 1000 1000 / 1000 1000 / 1000 11/2" (40) 1001-11/2 X 1 107.0 (48.5) 1001-11/2 X 11/4 124.7 (56.6) 1500 / 1500 1500 / 1500 1500 / 1500 2" (50) 1001-2 X 1 112.6 (51.1) 1001-2 X 11/4 129.2 (58.6) 1500 / 1500 1500 / 1500 1500 / 1500 *21/2" (65) 1001-21/2 X 1* 136.3 (61.8) 1001-21/2 X 11/4* 154.4 (70.0) 2000 / 2000 2000 / 2000 2000 / 2000 3" (80) 1001-3 X 1 145.0 (65.8) 1001-3 X 11/4 163.1 (74.0) 2000 / 2000 2000 / 2000 2000 / 2000 4" (100) 1001-4 X 1 158.6 (71.9) 1001-4 X 11/4 176.7 (80.1) 2000 / 2000 2000 / 2000 2000 / 2000 5" (100) 1001-5 X 1 173.2 (78.6) 1001-5 X 11/4 191.4 (86.8) — / — 2000 / 2000 2000 / 2000 *6" (150) 1001-6 X 1* 190.0 (85.2) 1001-6 X 11/4* 206.0 (93.4) 2000 / 2000 2000 / 2000 2000 / 2000 *8" (200) 1001-8 X 1* 217.4 (111.5) 1001-8 X 11/4* 265.3 (120.3) — / — 2000 / 2000 2000 / 2000 * Note: Metric sizes available for 65mm, 150mm, 200mm pipe size with 25mm and 32mm brace pipe size. Contact the factory. OPM Fig. 1001 Se i s m i c B r a c i n g Seismic Bracing All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 74 B-Line series Fire Protection SolutionsEaton TOLCO Fig. 4L - sway brace attachment (UL listed) Size Range: 1" (25mm) through 8" (200mm) IPS. 10" (250mm) and 12" (300mm) not UL listed Material: Steel and stainless steel. Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 1" (25mm) through 8" (200mm) pipe. UL Listed for the following sprinkler type pipes: Sch. 40, Sch. 10, Bull Moose Eddy Flow, Wheatland Mega Flow, DIN 2448, KSD 3562, KSD 3507. Ask the factory for additional information as it may vary by product size. For FM Approval information refer to FM Approved page 75. Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Installation Instructions: Fig. 4L is the “braced pipe“ attachment component of a longitudinal and lateral sway brace assembly. It is intended to be combined with the “bracing pipe“ and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 guidelines should be followed. (For complete detailed instructions see instruction sheet IL309015EN). To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage “bracing pipe” into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain, Electrogalvanized, Hot Dip Galvanized or Stainless Steel (only for 4" & 6" sizes). Order By: Figure number, pipe size and finish. Eaton’s B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. D A CC A D Set Bolt & Hardware Included OPM Lateral Brace Longitudinal Brace With Plain & Electrogalvanized Finish With Hot Dip Galvanized & Stainless Steel Finish UL Max. Rec. Load PLN & EG. Approx. Part No. Nom Pipe Size A (Max)C D Bolt Size Logitudinal Lateral in.(mm)in.in.in.in.lbs.lbs.Wt./100 lbs. 4L-1 1 (25)5 2 13/8 1/2-13 1000 1000 176 4L-11/4 11/4 (32)52/7 21/16 15/9 1/2-13 1000 1000 182 4L-11/2 11/2 (40)51/2 21/3 12/3 1/2-13 1000 1000 187 4L-2 2 (50)62/7 22/3 2 1/2-13 1600 1000 204 4L-21/2 21/2 — 67/9 3 21/3 1/2-13 2000 1000 217 4L-65mm — (65)67/9 3 21/3 1/2-13 700 1000 214 4L-3 3 (80)73/7 31/4 25/8 1/2-13 2000 1000 323 4L-31/2 31/2 (90)8 31/2 27/8 1/2-13 2000 1000 343 4L-4***4 (100)83/7 33/4 31/8 1/2-13 2000**1000 253 4L-5 5 —95/9 43/8 35/8 1/2-13 2000** 1600*314 4L-125mm —(125)95/9 43/8 35/8 1/2-13 1200 1600*314 4L-6***6 —113/7 51/3 44/7 1/2-13 2000 1600*540 4L-150mm —(150)113/7 51/3 44/7 1/2-13 1200 1600*538 4L-8 8 —133/5 62/5 52/3 1/2-13 2000 2100*645 4L-200mm —(200)133/5 62/5 52/3 1/2-13 1400 2100*643 4L-10****10 (254)173/5 81/4 71/4 1/2-13 NA NA 1349 4L-12****12 (300)193/5 91/4 81/4 1/2-13 NA NA 1526 * Only UL listed as a lateral brace for use with a 1" (25mm) pipe as the brace member. ** Only UL listed as a longitudinal brace for use with a 1" (25mm) thru 11/2" (40mm) pipe as the brace member. *** Fig 4L-4 and Fig 4L-6 are only sizes available in stainless steel 316. **** FM approved not UL listed. Updated 4-2-21 Se i s m i c B r a c i n g Seismic Bracing All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 60 B-Line series Fire Protection SolutionsEaton Size Range: One size fits bracing pipe 1" (25mm) thru 2" (50mm), B-Line series 12 gauge (2.6mm) channel. Material: Carbon steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product’s design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections and in accordance with NFPA 13, 2019 Section 18.5.11.5. The Fig. 980 mounts to any surface angle and the break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the “bracing pipe” and TOLCO™ “braced pipe” attachment, Fig. 1001, 2002, 3000, 4L or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the “bracing pipe”. Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). UL Listed for the following brace member type pipes: Sch. 40, KSD 3562. Ask the factory for additional information as it may vary by product size. Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. For FM Approval information refer to FM Approved page 61. Note: Fig. 980 Swivel Attachment and Fig. 1001, 2002, 3000, 4L, or approved attachment to pipe make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact customer service for alternative finishes. Order By: Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Eaton’s B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. Longitudinal Brace Fig. 980 - TOLCO Universal swivel sway brace attachment -3/8"-16 to 3/4"-10 rods Fig. 980H - TOLCO Universal swivel sway brace attachment -7/8"-9 to 11/4 "-7 Mounting Hardware Is Not Included Set Bolt Included Fig. 4B shown Fig. 980 Fig. 980 OPM Lateral Brace Brace Fig. 1001 Fig. 980 A D B B D A 980 A B D**Max. Design Load (cULus) lbs./(kN) Approx.Wt./100 Catalog #in.(mm)in.(mm)in.(mm)lbs.(kg) *980-3/8 49/16 (114.9) 21/16 (52.4) 7/16 (11.1)1600 (7.12)149 (67.6) *980-1/2 9/16 (14.3)2100 (9.34)148 (67.1) *980-5/8 11/16 (17.5)2100 (9.34)147 (66.7) *980-3/4 13/16 (20.6)2100 (9.34)146 (66.2) 980H-7/8 63/4 (171.4) 31/2 (88.9) 15/16 (23.8)Fig. 980H is not UL Listed or FM Approved 402 (182.3) 980H-1 11/16 (27.0)400 (181.4) 980H-11/8 13/16 (30.2)397 (180.1) 980H-11/4 15/16 (33.3)390 (176.9) * Sizes available in stainless steel (980S-3/8, 980S-1/2, 980S-5/8, and 980S-3/4) and have the same UL rating as what is listed. ** Mounting attachment hole size. PRINTED IN USA PAGE 1 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 UL, CUL and CSFM Listed, FM Approved, LPCB Approved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Ordering Information Nominal Pipe Size Model Part Number 2"DN50 VSR-2 1144402 2 1/2"DN65 VSR-2 1/2 1144425 3"DN80 VSR-3 1144403 3 1/2"-VSR-3 1/2 1144435 4"DN100 VSR-4 1144404 5"-VSR-5 1144405 6"DN150 VSR-6 1144406 8"DN200 VSR-8 1144408 Specifications subject to change without notice. Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 2 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. ADAPTER USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DN50 ONLY ADAPTER 50mm 20mm ±2mm MAX. DWG# 1146-1F Fig. 1 NOTE: For copper or plastic pipe use Model VSR-CF. Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms (Flowing water activates device in one direction only.) DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOWDIRECTION OF WATERFLOW Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts TorqueLightwallSchedule 10 (UL)Schedule 40 (UL)BS-1387 (LPC)DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .125/- .062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 -2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 ---- VSR-2 1/2 -DN65 3.000 76.1 ------0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ± .125 50.8 ± 2.0 VSR-3 1/2 3.5 -4.000 101.6 --0.120 3.05 0.226 5.74 ---- VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 -5.563 141.3 --0.134 3.40 0.258 6.55 ---- VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 --0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. PRINTED IN USA PAGE 3 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. DWG 1146-4 Fig. 2 Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Terminal Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector’s test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions DWG. 1146-14 3.50 in (89.0 mm) 2.34 in (59.4 mm) PIPE DIA. + 5.25 in (+ 133.4 mm) 5.56 in (141.2 mm)2.00 in (50.8 mm) U-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 – DN 65 2–2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 – DN 200 3–8 in DWG 1146-15 GREEN GROUND SCREWS Fig. 7 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see “Switch Terminal Connections” drawing and warning note (Fig. 4). Fig. 5 Typical Electrical Connections LO AD TO B E L L NEUTRAL FROM BELL CONNECTOR EOL (End Of Line Resistor) BELLNEUTRAL FROM BREAKER BREAKER LINE FROM BREAKER NOTE: When connecting to a UL Listed control panel, use the panel’s resistor value for circuit supervision. PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 4 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Removal of Waterflow Switch • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. Fig. 8 Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. DWG# 1146-10 BREAK OUT THIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. DO NOT REMOVE (2) RETARD HOUSING SCREWS REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE RETARD/SWITCH ASSEMBLY (2) ORIGINAL MOUNTING SCREWS (2) LOCATING PINS (2) LOCATING PIN BOSSES IN BASE BASE BELLS PBA-AC & PDC-DC 5400777 - REV A • 12/20 PAGE 1 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4” (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to PDC-DC bells. Technical Specifications Dimensions 6” (150mm), 8” (200mm) and 10” (250mm) Enclosure Cover: Steel Finish: Red Powder Coat Base: non-corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) Voltages Available 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Environmental Limitations Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination AC Bells - 4 No. 18 AWG stranded wires DC Bells - 18 AWG stranded wire Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4” box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6”, 8” and 10” sizes In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. R * ULC on PDC-DC Only Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150)12VDC PDC-6-12 1750500 200mA 96 76 8 (200)12VDC PDC-8-12 1750502 .200mA 96 77 10 (250)12VDC PDC-10-12 1750504 .200mA 96 78 6 (150)24VDC PDC-6-24 1750501 .20mA 95 77 8 (200)24VDC PDC-8-24 1750503 20mA 83 79 10 (250)24VDC PDC-10-24 1750505 20mA 85 80 6 (150)24VAC PBA246 1806024*.17A 91 78 8 (200)24VAC PBA248 1808024*.17A 94 77 10 (250)24VAC PBA2410 1810024*.17A 94 78 6 (150)120VAC PBA1206 1806120*.05A 92 83 8 (200)120VAC PBA1208 1808120*.05A 99 84 10 (250)120VAC PBA12010 1810120*.05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. *** ** FM on PBA-AC Only 5400777 - REV A • 12/20 PAGE 2 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com BELLS PBA-AC & PDC-DC Wiring Rear View Installation Bell Dimension Inches (mm) Fig 1 Fig 3 2 11/16” (68 mm)DWG# 776-1 10” (250 mm)8” (200 mm)6” (150 mm) 5 3/4” (146 mm) 1 5/8” (41 mm) DWG# 776-2 3 3/8” (86 mm) 4 1/4” (108 mm) 3 3/8” (86 mm) 5” (127 mm) Weatherproof Backbox Dimensions Inches (mm) Fig 2 The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90” AFF and not less than 6” below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). MODEL BBK-1 OR HC-BBFailure to install striker down will prevent bell from ringing. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS .