Loading...
Energy Code WorksheetWSU Code Compliance Calculator, WSEC 2018 Project Information Messages / Comments * Plan - 2853B Review required for custom entries: - Doors UA Reduction = 26, Proposed UA is better than baseline by 7.3% Contact Information Soundbuilt Homes LLC Window area is 11% of floor area PO Box 73790 - Puyallup, WA 98373 Whole House Mechanical Ventilation Airflow Rate: 45 CFM with Run Time Percent of 100%, Balanced, Distributed 253-848-0820 Maximum allowable total measured duct leakage: 228 CFM25 ANALYSIS SET UP What code compliance pathway are you using? Project Building Type? Occupancy Type? Code Version? WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/O Classification:Medium Dwelling Unit -- 2853 sq. ft. Baseline Description: Code Baseline - Baseline and proposed window areas are equal. About Your Selection:Up to 15 sf exempt window and 24 sf exempt door allowable RESULTS - Comparison of Baseline and Proposed Design ** Component Performance, R occupancies U *Area UA Area UA Doors U =0.300 86 25.7 86 19.9 Overhead Glazing U =0.500 0 0.0 0 0.0 Vertical Glazing U =0.300 321 96.2 321 96.2 Flat/Vaulted Ceilings U =0.024 1,322 31.7 1,322 33.1 Wall (above grade) U =0.056 2,392 134.0 2,392 134.0 Floors over Crawlspace U =0.029 2,392 69.4 2,392 47.8 Slab on Grade F =0.540 0 0.0 0 0.0 Below Grade Wall U =N/A 000.0 Below Grade Slab F =N/A 000.0 * Values from Table R402.1.2 (Oct 2023) Baseline UA Total 356.9 Proposed UA Total 330.9 Required Credits 8.0 Proposed Credits 8.0 from Tables 406.2 and 406. UA Percent Reduction 7% UA Reduction 26.0 If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406 are ≥ those required in Section R406, then the home meets the WSEC. ** Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Total Credits (406.2 & 406.3) 8.0 0.300 0.025 0.056 0.020 Proposed Design U-Factor Compliance Path / Total UA Alternative U Baseline New Construction R3 Single family dwellings and townhouses WSEC 2021 0.232 Brief Description of Selected Options* 1.5 Category Select System TypeSystem No. 4 Option 2.2 Fuel Normalization Credits (406.2) 1 Option 3.6 5.0 Full Description For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI 550/590 High Efficiency HVAC Energy Credits 3.11 High Efficiency HVAC: Smart Thermostat 0.0 Table R406.2 Energy Equalization Credits 3.0Variable Refrigerant Heat Pump or Air-to- Water Heat Pump Select Options Per Section R402.4.1.2 /1.5 ACH50 / For R-2, 0.20 cfm per ft2 at 50 Pa. / HRV with min SHR eff of 0.75 per IRC Section M1505.3 or IMC Section 403.8 Table R406.3 Energy Credits Option No. 2 Air Leakage Control and Efficient Ventilation Efficient Building Envelope 3.1 -3.10 Energy Credits (406.3) * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Air source ducted Heat Pump w/ Min HSPF2 of 10 (HSPF of 11). If htg design temp is 23F or below,a cold climate variable capacity heat pump is required. 1.0 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Renewable Electric Energy kWh Energy Credits *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements 4 Option 4.1 Option 5.6 0.0 0.0 High Efficiency HVAC Distribution System 7 Appliance Package Efficient Water Heating: Drain Heat Recovery Efficient Water Heating Efficient Water Heating: Compact Hot Water Distribution 5.1 5.3-5.8 5.2 6 2.0 5.0 Ducts/distribution system in conditioned space per R403.3.2 Electric resistance, hydronic, ductless and gas fired systems < 80% AFUE systems not permitted 0.0 Electric heat pump water heater meeting NEEA Tier 3. 0.5 0.0 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area, Proposed Design 2,853 sq. ft Classification Medium Dwelling Unit Exterior Doors Plan Component Door ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt 00.0 Solid Core Door Custom 0.17 1 2 8 6 8 18 3.0 Refer to WSEC R402.1 Fiberglass Door Custom 0.15 1 3 6 8 20 3.0 Refer to WSEC R402.1 Sliding Door Custom 0.29 1 6 8 48 13.9 Refer to WSEC R402.1 00.0 00.0 00.0 00.0 00.0 00.0 00.0 Sum of Area and UA 86 19.9 0 3 Exterior Doors Area Weighted U 0.232 Overhead Glazing Plan Component Glazing ID Description U Feet Inch Feet Inch - - - - - 0.0 0 0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 13 Plan Component Glazing ID Description U Feet Inch Feet Inch Exempt - - - 1 U=0.30 (Code Baseline)Table 406.2 0.30 1 2 5 10.0 3.00 2 U=0.30 (Code Baseline)Table 406.2 0.30 2 5 5 50.0 15.00 3 U=0.30 (Code Baseline)Table 406.2 0.30 1 3 4 6 13.5 4.05 4 U=0.30 (Code Baseline)Table 406.2 0.30 1 8 5 40.0 12.00 5 U=0.30 (Code Baseline)Table 406.2 0.30 2 2 6 5 25.0 7.50 6 U=0.30 (Code Baseline)Table 406.2 0.30 1 4 2 8.0 2.40 7 U=0.30 (Code Baseline)Table 406.2 0.30 1 4 4 6 18.0 5.40 8 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 4 6 27.0 8.10 9 U=0.30 (Code Baseline)Table 406.2 0.30 2 2 3 12.0 3.60 10 U=0.30 (Code Baseline)Table 406.2 0.30 3 4 4 48.0 14.40 11 U=0.30 (Code Baseline)Table 406.2 0.30 2 6 4 48.0 14.40 12 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 2 12.0 3.60 13 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 1 6 9.0 2.70 Sum of Area and UA 320.5 96.2 0 Vertical Glazing Area Weighted U 0.300 Vertical Glazing and Doors Area Weighted U 0.286 Flat/Vaulted Ceilings Plan Component Attic ID Description U R60 blown Attic STD baffled 10-7 0.025 1,322 33.1 1,322 33.1 0 UA Area UARef. Sum of Area and UA Ref. Ref. Height Notes Height Area Width Qt. Sum of Area and UA Qt. UAArea HeightWidth Width 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Walls (Above Grade) Plan Component Wall ID Description Ref. U UA R21 cavity+R0 foam INT 2X6W T111 (Code Baseline)10-5 0.056 2,392 134 2,392 134 0 Net Area Sum of Area and UA 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref. U R48 vented Joist (2021 1.4; 2018 1.6)0.00 0.020 2,392 48 2,392 48 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab ID Description Ref. F FP 00 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab ID Description Depth Ref. U Area UA UA Sum of Area, Length and UA 0 0.0 0 0 0 Links to Download Forms, Checklists and Other Resources Compliance Certificate Instructions Insulation Certificate for Residential New Construction Duct Testing Affadavits Existing Construction New Construction Prescriptive Checklist for 2018 WSEC Alterations (Remodel) Worksheet EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter Show Ventilation Requirements Conditioned Floor Area 2,853 sq. ft. Number of Bedrooms 1 Run-Time Percent in Each 4-Hour Segment 100% Is the system Balanced?Verify system meets definition of 'Balanced Whole-House Ventilation' Is the system Distributed?Verify system meets definition of 'Distributed Whole-House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 45 CFM Show HVAC Thermal Distribution System Download RS-33 (2018) Is this a hydronic heating system? Location of Ducts Location of Air Handler Is Duct Testing Required? Yes Maximum Duct Leakage: Maximum total measured duct leakage per square foot 0.08 CFM25 per sq. ft. Maximum allowable total measured duct leakage 228 CFM25 A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7. Show Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: Nearest Weather Station Indoor Design Temperature 70 F Outdoor Design Temperature 17 F F Slab Slab Perim Lacey Conditioned Space Show Heating System Sizing? Area No Sum of Perimeter and FP Slab Perim Compliance Certificate Insulation Certificate Sum of Area and UA Distributed Balanced Show Distribution System Calculator? Show Ventilation Calculator? http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%2 Conditioned Space https://betterbuiltnw.com/resources/hvac-sizing-tool Link Prescriptive Checklist Affidavit, Existing Affidavit, New Worksheet 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Design Temperature Difference (∆T)53 F Conditioned Floor Area, Proposed Design 2,853 ft2 Conditioned Volume 22,824 ft3 0.00 Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Location of HVAC Distribution System Conditioned Space Sum of UA, including exempt door and window 331 Envelope Heat Load 17,540 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 13,064 Btu / Hour ((Volume X 0.6) X ∆T) X .018)) Building Design Heat Load 30,604 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 30,604 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 38,255 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 11.2 kW Building and Duct Heat Loss X 1.40 for all other systems Heat Pump 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024