9983 Jackson St SE Yelm Adult Family Home Remodeling 2CODE NOTES: • W211RC R310.1 EMERGENCY ESCAPE AND RESCUE OPENING REQUIRED BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOT LESS THAN ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING • M21 IND R3102.1 MINIMUM OPENING AREA EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24INCHES AND THE NET CLEAR WIDTH SHALL NOT BE LESS THEN 20INCHES. EXCEPTION: GLADE ROOR OR BELOW GRADE OPENING SHALL HAVE A NET CLEAR OPENING OF NOT UESSTHAN 5 SQUARE FEET. • M21 INC R31022 WINDOW SILL HEIGHT WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPEAND RESCUE OPENING, ITSHALL HAVE A SILL HEIGHT OF NOT MORE THAN 41NCHES ABOVETHE FLOORWHERE THE SILL HEIGHT IS BELOW GRADE, ITSHALL BE PROVIDED WTIH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2.3. MI IRC SECTION R330 ADULT FAMILY HOME Ml INC 330.6 ESCAPE WINDOWS AND ODORS EVERY SLEEPING ROOM SHALL BE PROVIDED MTH EMERGENCY ESCAPE AND RESCUE WINDOW AS REQUIRED BY SECTION R310. NO ALTERNATIVES TO THE SILL HEIGHT SUCH AS STEPS, RAISED PLATFORMS OR OTHER DEVICES PLACED BY THE OPENINGS WILL BE APPROVED AS MEETING THIS REQUIREMENT. 90I.2.10.5 INTERCONNECTION WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT OR SLEEPING UNIT IN GROUP R OR I -I OCCUPANCIES, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE INDMGUAL UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE REQUIRED MERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UPON ACTIVATION OF ONE ALARM. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL THE BEDROOMS OVER BACKGROUND I LEVELS WITH ALL INTERVENTNO DOOR CLOSED R33U,6.5.1 VERTICAL GRAB BAR VERTICAL GRABS SHALL BE 181NCH MINIMUM IN LENGTH AND INSTALLED AT THE CONTROL END WALL AND HEAD END WALL. VERTICAL BARS SHALL BE MOUNTED WITHIN 41NCHES OF THE EXTERIOR OF THE SHOWER STALL OR WRHIN 4INCH ES INSIDE THE SHOWER STALL.THE BOTTOM END OF VERTICAL BARS MOUNT BETWEEN 36INCHES AND 421NCHES ABOVE FLOOR GRADE. R33U,6.5.2 HORIZONTAL GRAB BAR HORIZONTAL GHAS BAR SHALL BE INSTALLED ON ALL SIDES OF THE SHOWIER STALL MOUNTED BETWEEN 331NCHES AND 361NCHES ABOVE THE FLOOR GRADE. HORIZONTAL GRAB BARS SHALL BE A MAXIMUM OF 6INCH ES FROM ADJACENT WALLS. HORIZONTAL GRAB BARS SHALL NOT INTERFERE MTH SHOWER CONTROL VALVES. GARB BARS SHALL HAVE A SPACING OF 1)5' BETWEEN THE WALL AND THE BAR. PROJECTING OBJECTS, CONTROL VALVES AND BATHTUB OR SHOWER STALL ENCLOSURE FEATURES ABOVE BELOW AND AT THE ENDS OF THE GRAB BAR SHALL HAVE A CLEAR SPACE OF 1$' INCHES TO THE GRAB BAR. UN 82 GRAB BAR INSTALIATION.EXCEPTION SWING UP GRAB BARS SHALL NOT BE REQUIRED TO MEET THE 1$ INCH SPACING REQUIREMENT. GRAB BARS SHALL NOT HAVE STRUCTURAL STRENGTH OF 2% POUNDS APPLIED AT MY POINT ON THE GRAB BAR, FASTENER, MOUNTING DEVICE OR SUPPORTING STRUCTURAL MEMBER R330,8.3 GRAB BAR AT WATER CLOSETS WATER CLOSET SHALL HAVE GWB BAR MOUNTED ON BOTH SIDES. GRAB BAR CAN BE A COMBINATION OF FIXED POSITION AND SWING UP BARS. GRAB BARS SHALL MEET THE REQUIREMENTS OF R330.8 GRAB BAR SHALL MOUNT BETWEEN 33INCH BE AND 36INCHES ABOVE FLOOR GRADE. CENTERLINE DISTANCE BETWEEN GRAB BARS, REGARDLESS OF TYPE USED, SHALL BE BETWEEN 251NCHES MINHAD AND 30 INCHES MAXIMUM. GENERAL PLUMBING NOTE 1. DRYER, WATER HEATER, KITCHEN AND BATHROOM VENTING SHALL EXHAUST TO THE OUTSIDE OF THE BUILDING AND BE EQUIPPED WITH A BACK DRAFT DAMPER.VENT DRYER VENT, MAX. LENGTH OF DUCT 14' WITH TW0 90 DEGREE ANGLES. 2. PROVIDE 3P CLEARANCE FROM RANGE TOP TO COMBUSTIBLE MATERIALS, FOR EXCEPTIONS, SEE INT, MECHANICAL CODE. SIDE CLEARANCE SHALL BE AS SPECIFIED BY PERMANENT MARKING ON THE UNIT.-IRCM1901.1 3. WATER CLOSETS TO HAVE A ROW RATE OF 16 GALLONS OR LESS PER FLUSH.-IRC PZ6032 4. SHOWER HEADS TO HAVE FLOW RATE OF 2.5 GALLONS PER MINUTE OR LESS. -IRC P2W3.2 5, TUBSISHOWERS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATC MIXING TYPE. THE WATER TEMPERATURE SHALL BE AT A MMIMUM OF 120'F. 6. INSTALL WATERPROOF GYPSUM BOARD AT ALL WATER SPLASH AREAS TO MINIMUM BC' ABOVE SHOWER DRAINS. ], WATER SOFTENER UNIT SHALL CONDITION WATER BEFORE ENTERING THE WATER HEATERS AND THE COLD WATER SOURCE. WATER TO REFRIGERATOR KITCHEN AND BATH SINKS SHALL NOT HAVE SOFTWATER. 8. EACH HOSE BIBB SHALL BE EQUIPPED WITH A BACK FLOP/ PREVENTION DEVICE. 9. ALL GAS LINES SHALL BE SIZED FOR APPLIANCE LOAD.'BLACR' PIPE SHALL BE USED INSIDE THE BUILDING 'GREEN' PIPE WHERE 10. INSULATE WASTE LINES FOR SOUND CONTROL. 11. INSTALL CENTRAL VACUUM SYSTEM 8 PIPING; CONFIRM BRAND WITH HOMEOWNER. SKETCH HOUSELTANT CESICNERSBBNLOINGCCNWCTANi CUENT NAME: DRAWING TRLE: CODES NtV61[]N] PARCEL N"ER: pesi ed SL NlQ024 ]Efi4012]5v0 Drvvn SL 9Rif1024 JOB N0. _ Dot. posnptlm A, —ad BUILDING PLANS CONTACT-SHANTANUTAL TRADE DIPLOMA IN ARCHITECTURAL LOCI yy ¶!L .- --' JOHNSON CHeckad SL 9R112024 SCALE: SHEET N0. - PROJECT TIRE MDBIIE:LA3H33Y940t EMNL:IALewal[Aglrei.wm SKETCH HOUSE � woe. e. eni.b ADULT FAMILY HOME -REMODEL 9983 JACKSON ST YELM859 , WA 9T Approved DPI. NTS Title Jvd CCl.,Ref: �M1 CONTENTS AND KEY A - Norb Maw and awls indicator B -Sire Parcel Addre„ C -Pmcel Number D- N. ofproper, owner E-Show all proper, Imp. Indiaarethe lwgdt of aide and aegmenn. If break III q used. Itldlfine the length on aeeh side of rob arc ENGINEERING P-Swaf,an, Drat ludo nMaeoum 6-8apfic Moo, Show obac arddo.. dramfiran E waidon dQpraaEackdlamnm Bom residwceatdproperry lino H-WatcrmOBa andami0c lice tar -IT BOUNDARY LINE 1-Strom urvia or infilrmnon system I �___________________Ir____________________________________________________________________________- T-Pudmnks 1 1 4 V 1 K-SOMwmc 1 1 1 L Eaxemwt B..d, and width 1 1 1 (PdveNand WHlo) M-DtivewaYa 1 1 x 1 N-Exist, Trea-Skwlowrionofall axitingrreannailewibaiplvle 1 1 v O 1 aM wTDECK ENVIRONMENMENTAL.AL 0-NanvalbuRroarbowdar (NBA) ; 1 2tlA' • C3 j P-C'fmal tow and I orcritical bnlTem ( said ands,sBepsloPeems, 1 E 1 1 1 E Streams wdstream buno,'I ) Q- Shmegna(Orrhan, higy warx Mark, 1 I t I (OHWM) 1 c 1Tb�a 20-1 lie' q R-Wanxfemures,atrwros,dranageaM 1 w_ w Sea,wal9wil> — 3-Provide common Gt everychenge In 1 � I II I gmwdelevadon of2'.Ifelamion m z araukaownd.,nateaaro 1 o f T t o 'I'vmion'int as a alarling Ref O m i PAVED PROPOSED CORD. i m I STRUCTURES ; ; DRIVEWAY VERTICLE HT=18' T HORNTL LNTH=18'fo T arawriotofdlexi,lingand or Twad 1 1 O 1 slarwart Label"Exisring"or'Propoud" 1 1 1 U-Dlmensiomofill as ac All 1 1 1 2xiefingaM proposed (All aide) 1 1 II 1 V-SwRoka Indicatedisbm'0sfi0m Pmt 1 1 — / — � 1 livaaumares i i 0 x \ / i W-Indiwred utencabetwttnexut�tlg& 1 1_ _ _ _ _ _ _ _ _ _ _ — 1 Pmpwedsuuctma 1 1 r 1 'Existi X-9howillaeb,petlwxonining wiles, y BWkhwds,m.Lehlng "ProPosd' 1 1 1 1W'L' BOUNDARY LINE` E B 9B3 JACKSON ST YELL, WA 98597 (—PARCELM78640127500 NER JOHNSON D CLENT NAME DRAWING TITLE: REVISIONS PARCEL NMIBER: Ixsi ed sL 921W4 JOB W. I)ESKSKETCH CONSULTANT Dote povriptivn Applavd _ BUIMINERSBBNLOINGCCNSIILTANi SITE pIAN ]BE4012I500 Draw, SL 9R1f1024 BOIIDINTPLWS y PMI DIPLOMA ARCHITECTURAL ¶!L JOHNSON Checked SL &1I12020 SHE♦7 ND. IIMLE OIPLOM1N IN ARLHITECiORALiELHNOLOGYI -- -- PROJECT TI1LE SEptE; Add OSUI SKE'1'(�`H__] OUSE ADULT FAMILY HOME- REMODEL Approved DPt. — EMNLI1'aunne3Y940t 9983 JACKSON ST YELM, WA 95597 313P'1'0" Title Jvd Chao— Ref. 1 rot FNNL'IeLewae®gnei.wm w"Ie. e. �eni.b SB'Lx SOWII M xT=E=1P OPENiBIE= 4.S BF 9d1x1'SW SILLIR=41' OPENPBLE =119F B'D" 11'-9' 1T-11' 1O-0" 5'-0" 10'S• CIJENT NAME: THAWING TRUE: REVISIONS PARCEL NMIBER; pesi MSL 921M4 JOB W. SNETCH HOUSE DESIGN 9n CESIGNER58BUILDING CONSULTANT Dvta povtlpPim Ayrovd EXISTING ISO FLOOR PLAN TSfi4G12T50G Orvvn SL 9212024 BUILDING LAAS CONTACT SHAN y Checked SL 911T2024 SHEET NO. WNTACT-SHANTA ARCHI ¶!L JOHNSON DPT[E DIPLGMA IH ARLHITECiOPAL iELHNOLOGYI . - -- PROJECT TITLE SCALE;WBILA01 SKETCH HOUSE ADULT FAMILY HOME- REMODEL APPwved Dvte WAIL aIamlK,@gmiI1 SWISS JACKSON ST YELM, WA 9S591 1I9"-1'-0 Tlkle Jvd Clvss� RN: EMNL:IeLewaR®9m+il.wm vnlen �e .eali ® 1ali /BIfUB ` � O WALK-IN J CL0.5ET y � � BEDROOM 6NV 3 (PRIMARY BEDROOM) GARAGE v SJI' y LADNDRr L9 LIVING n BUILDING PLANS CONTACT-SHNRPNUILAL FRADEDI LOMAIN AACHITECTUF4LTECHNCLOGY) CLIENT NAME: I ORAww TRLE: PROPOSED 1ST FLOOR PLAN SMOKE DETECTOR 50Rm EXHAUST PAN SCOPE OF WORK 1. INSTALL SMOKE DETECTORS AND FIRE SMOKE DETECTORS COMBO. 2. PROPOSED GONG. RAMP RAMP;NERTICALHEIGHT=18' HORIZONTAL LENGTH -18'V (SEE SHEET A09) AREA =904 3.WIDEN000RS(01) GENERAL NOTES 1 ALL SLEEPING ROOMS ARE CLASSIFIED AS "TYPE NS 1" INACCORDANCEWRH INC SECTION WAD 5140-03 R330.3 CONSTRUCTION NOTES 1. INSTALL NEW SMOKE AND CO DETECTORS PER IRC SECTION WAD 51-514300 RD0.5 2. INSTALL GRAB -BARS IN BATH ROOMS PER IRC SECTION WAD 51-514300 RM0.8 REOWREN (SEE SHEET A05) PARCEL NUMBER: T8640127500 JOB ND. SKETCH HOUSE JOHNSON PROJECT TIRE ADULT FAMILY HOME - REMODEL Q 99B3 JACKSON ST YELM, WA 9RHIT Checked SL KlCO24 SCALE. AP"—d Dole 11F40' Title Job cle — A02 zr-2. T-r I'-R• NOTES LOFT v�i 1. NO CHANGES DONE IN 2ND FLOM 9 - 2. SECOND FLOOR WILL BE OCCUPIED BY OWNER] CPREGI ER BEDROOM 4 CLOSET 2 BEUB m WC LJ HB o Y v BEDROOM 5 15'6• CLIENT NAME DRAWING TITLE: REVISIONS PARCEL NMIBER; peai MA 01M4 JOB W. SNETCH HOUSE DESIGN 9n DESIGNERS& BUILDING CONSULTANT Dvty pootlpPim Agnovd EXISTING 2ND ROOK PLPN ]BBg012]5D0 Orvvn SL 9RifM24 BWLDINT SHAH y Checked SL 9121n920 SHEET NO. JAI TRADED]-BHANTAH0141 ¶!L JOHNSON �IMLE DIPLOMA IH ARCHITECTURAL iELHNOLOGYI . - -- PROJECT TITLE SCALE; A03 welSKETCH HOUSE ADULT FAMILY HOME -REMODEL APPwved Dvte WALL alam9@,mil1 9983 JACKSON ST YELM, WA 99E9T N16•-10 Title Jvh CI., RN� 101 EMNL:IeLewaR®9m+il.wm vnlen �e .eel i 2'-$e MIN DOOR DETAIL -D1 DOOR REFERENCE MAIM: FRAME MATERIAL: HARDWOOD FRAMECOLOR: OWNERCHOICE DOORTYPE: HOLLOW CORE WOODEN DOOR HARDWARE: STAINLESSSTEEL KNOB STYLE DOOR LATCH: KWIKSET SAFE LOCK ( CAN BE UNLOCKED FROM OUTSIDE INCASE OF AN EMERGENCY EXTERNALDOORCOLOR: OWNERCHOICE LOCATION: BEDROOMSSBATHROOMS R330.4 TYPES OF LOCKING DEVICE AND DOOR ACTIVATION ALL BEDROOM AND BATHROOM DOORS SHALL BE OPERABLE FROM THE OUTSIDE WHEN LOCKED, EVERY CLOSET SHALL BE READILY OPERABLE FROM THE INSIDE. OPERABLE PARTS OF DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER DEVICES INSTALLED IN ADULT FAMILY HOME SHALL BE OPERABLE WITH ONE HAND AND SHALL HOT REQUIRE TIGHT GRASPING, PINCHING OR MISTING OF THE WRIST. POCKET DOORS SHALL HAVE GRASPABLE HARDWARE AVAILABLE WHEN IN THE CLOSET OR OPEN POSITION. THE FORCE REQUIRED TO ACTIVATE OPERABLE PART SHALL BE 50 POUNDS(22.2 N) MAXIMUM. REQUIRED EMT DOORS SHALL HAVE NO ADDITIONAL LOCKING DEVICES. REQUIRED EMT DOOR HARDWARE SHALL UNLOCK INSIDE AND OUTSIDE MECHANISMS WHEN EXITING THE BUILDING ALLOWING RE-ENTRY INTO THE ADULT FAMILY HOME WITHOUT THE USE OF KEY, TOOL OR SPECIAL KNOWLEDGE. BUSIES SMOKE AND CARBON MONOXIDE ALARM REQUIREMENTS ALL ADULT FAMILY HOMES SHALL BE EQUIPPED WITH SMOKE AND CARBON MONOXIDE ALARMS INSTALLED AS REQUIRED IN SECTIONS R314 AND R315.1. ALARMS SHALL BE INSTALLED IN SUCH MANNER SO THAT THE DETECTION DEVICE WARNING IS AUDIBLE FROM ALL AREA OF THE DWELLING UPON ACTIVATION OF A SINGLE ALARM. RSMS ESCAPE WINDOWS AND DOORS EVERY SLEEPING ROOM SHALL BE PROVIDED WITH EMERGENCY ESCAPE AND RESCUE WINDOWS AS REQUIRED BY SECTIOHR310. NO ALTERNATIVES TO THE SILL HEIGHT SUCH AS STEPS. RAISED PLATFORMS OR OTHER DEVICES PLACES BY THE BKETCH HOUSE DESIGN OESIGNE0.58 BDIIIIINGCONSDLTPM fi111LgNG PfANS CONTACT-S"HT U"' (TRADE II MA INAACHITECNFK TECHNOLOGY) MC&IE:(Y53F33T8`JJT EMNL'.INapl¢Q�nelm - - SKETCH HOUSE •�+•e. m poi q CLIENT NAME: JOHNBON DRAWNG TRLE: DOOR OEFAIL KLV61Orv] PARCEL NNNI ]004D12)500 50AyG 10 -0 9ne Desi d5L BI211202d J0B NO. - pate DOCription Ap ,m Drvvn SL W2112024 Chocked SL 9YtiRD24 SHEET N0. A04 PROJECT TIRE: ADULT FAMILY HOME - REMODEL � 99B3 JACKSON ST YELM WA 9059T Approved D.E. Ttly Jvd Clvss- Ret: 1 of T R330.8.5.1 VERTICAL GRAB BAR VERTICAL GRABS SHALL BE 181NCH MINIMUM IN LENGTH AND INSTALLED AT THE CONTROL END WALL AND HEAD END WALL. VERTICAL BARS SHALL BE MOUNTED WITHIN 4 INCHES OF THE EXTERIOR OF THE SHOWER STALL OR WITHIN 41NCHES INSIDE THE SHOWER STALL.THE BOTTOM END OF VERTICAL BARS MOUNT BETWEEN 36 INCHES AND 42INCHES ABOVE FLOOR GRACE R330.8.5.2 HORIZONTAL GRAB BAR HORIZONTAL GRAB BAR SHALL BE INSTALLED ON ALL SIDES OF THE SHOWER STALL MOUNTED BETWEEN 33INCHES AND WINCHES MOVE THE BOOR GRADE. HORIZONTAL GRAB BARS SHALL BE A MAXIMUM OF 6INCHES FROM ADJACENT WALLS. HORIZONTAL GRAB MRS SHALL NOT INTERFERE WRH SHOWER CONTROL VALVES. GARB BARS SHALL HAVE A SPACING OF Pt' BETWEEN THE WALL AND THE BAR PROJECTING OBJECTS, CONTROL VALVESAND BATHTUB OR SHOWER STALL ENCLOSURE FEATURES ABOVE BELOW AND AT THE ENDS OF THE GRAB BAR SHALL HAVE A CLEAR SPACE OF TV INCHES TO THE GRAB BAR. R330.8.2 GRAB BAR INSTALLATION. EXCEPTION SWING -UP GRAB BARS SHALL NOT BE REQUIRED TO MEET THE 1%, INCH SPACING REDDIREVERT GRAB BARS SHALL NOT HAVE A STRUCTURAL STRENGTH OF 250 POUNDS APPLIED AT ANY FORT ON THE GRAB BAR. FASTENER. MOUNTING DEVICE OR SUPPORTING STRUCTURAL MEMBER R330.8.3 GRAB BAR AT WATER CLOSETS WATER CLOSET SHALL HAVE GRAB BAR MOUNTED ON BOTH SIDES. GRAB BAR CAN BE A COMBINATION OF FIXED POSITION AND SWING UP BARS. GRAB BARS SHALL MEET THE REQUIREMENTS OF R330.S GRAB BAR SHALL MOUNT BETWEEN 331NCHES AND 36 INCHES ABOVE FLOOR GRADE. CENTERLINE DISTANCE BETWEEN GRAB BARS, REGARDLESS OF TYPE USED, SHALL BE BETWEEN 251INCHES MINIMUM AND SO INCHES MAXIMUM, R330.8A VERTICAL GRAB BARS. VERTICAL GRAB BARS SHALL BE MINIMUM OF 18INCHES LONG AND INSTALLED AT THE CONTROL END WALL AND HEAD END WALL GRAB BARS SHALL MOUNT WITHIN 41NCHES OF THE EXTERIOR OF THE BATHTUB EDGE OR WITHIN 41NCHES WITHIN THE BATHTUB. THE BOTTOM END OF THE BAR SHALL START BETWEEN 36INCHES AND 42 INCHES MOVE FLOOR GRADE 2 Y' lX'MIaSMAX DIA. STAINLESS MEL GW BARPBONDENSOLIDBLOCI NG INWALLATCONTACTPoINTS tN'MIN.SMAX NA.VAINLES551EELGRAH BARPRGVIDEUSgID&OCKING IN WALL AT CONTACT POINTS HLYE PATTERN ALLOWS FORMREWSSECURELY INTOTHESIUD SPECIFICKEDIRS: FINISH WIN R GAUGE . STAINLESS MEL - NO FART ROUNDER 2 UVEFAFE MUD WOU OETAILA �a PREMOCTIYE MUSERATEOELAIL MOUNTS SCAEMS PER STUD ELEVATION EDGEOF 0 9 n STALL BBEGIN 45BEGINNINGC£ SLOPE)FLGGR 5 L' W I ONIS: II YATERLLL:3pCSTAINLESS STEEL FINISH, SATIN HEAVY DUTY MOUNTING P kTES FIVE ATTACHMENT MINESSWING WHEN UP POSITION FCN WHEN NOT IN USE GRAB BAR DETAILS DeruLA SKETCHHCONSULANT DESIGNERSLANS ABUIIDING CONSULTANT - I, Cl1ENT NAME: ORAINNO TITLE GRAB BAR DETAILS REVISIONS PARKEL NUMBER: T864012T500 Designed SL V21QO24 JOB N0. _ Data Description AIBUILDIN Oravn SL 912V2024 CONTACT SHANTPNUTAL imm l JOHNSON Chocked SL 9OHM4 SHEFT N0. UWE GROWN IN PRCHIIELNRPI TECHNOLOGY D Y PROJECT TTTI£: EX;ALL A05 MOBILE' WADIA&FAIIGEMI FLWL'. M.utl¢WTmelm SKETCH HOUSE males ie �ea�w ADULT FAMILY HOME - REMODEL 9963 JACKSON ST YELM, WA W597 310-1-0 APprovea Title Bat• Job Clvss_ RCL 1N1 IPFAlED11MBER `EDRFIXING FORT ppyT SIDED) (SEE POST DETNL) CON0RAIL)S CWIINOWDBDTI ENDS N_RNED x ND RAMS ro NO NO RA P Y PI AT OF A0 0. % 0 IF o 4� 0 s0 FRONT ELEVATION 22.0 q \ PLAN VIEW y. 2'0 Timber H n 2a FAIL DURING 44TIEATEDTIMBER Rail @4'OC MAX POST (SEE POST FIXING DETAIL) 4"K4" treated Timber Post rn d N HAND RAIL DETAIL SCALE 15 8.3%SLOPE REDINGCON ATGRnnE VIEW A SKETCH HOUSE OESIGN - CuNAME OWING TRLE: REVISIONS PAFti NIIIIMR: Designed SL 9 JIM24 JOB NO. Date pesCription Aryrowd OEDIGNERSBRUIIIIINGCDNSULTPM OFIGNERS&B .- RAMP PLAN ]869U12]SDU Drvvn SL 92112024 CONTACT-SHWANUTAL liy JOHNSON Checked SL MlN024 SHEET NO. UWE NPLCM4 IN PRCHTIELNRPI TECHNOLOGY) PROJECT T)TLE: XA-f: A06 HOUSE ADULT FAMILY HOME - REMODEL Approved Dote MODILF(2 Iett3NJ1 EMMLIIN4EBI¢(�ABIPom .0 v..en ioa.vy 9SKETCH 9963 JACKSON YELM, WA W59] 112-1-4' Mls Job Clvss� Ref: �a11 F7 OO 4wmeATEDNMBER POST PLAN VIEW M TREATED TIMBER RUNNER SIIMPSON LO 26 FACE MJOM JOIST HANGER, GALV 4W lRFAlE0PMO / dxd TPFATEOiIMEFR G LL POST of I V POST II C I oC EZSIMPSONP=EUSE SU3xY'HOTmPOALv LAGS HERE 2v8TRFATEOTIMBERRUNNER (QEASIDE, 121SIL6 (dl$'6x<'ANLHgi BOL3 SUh?0xPGALVBOLT, NUTS 6WASHE0.5 (1)EALEGUP, QUUEGSILIPS a I o i f III o `� W �e. LIµyI -AITEGWNC. POST FIXING DETAIL RUNNER TO POST FIXING DETAIL RUNNER END TO POST FIXING DETAIL SKETCH HOUSE DESIGN DESIGNERSBBUIIIIINGCONSULTPM Cl1ENi NAME DRAWING TITLE: RAMP CONNECTION DETAIL I+LVISIUNS PARCEL MINBER: Designed GL &2112024 ]869G12]500 Drvvn GL 92112)24 JOB NO - Dete De.CHPnnn Appewd COI(T GPlANS LLMALT-SHPIRPNU Lll ITRIDEpRCM41N PRCHIIELNRPIIELHNOLOGV - r. JOHNSON Chocked SL 9YBRO20 SEALS: SHEET N0. AO] PROJECT TITLE: MOBIUSKETCH DUAL W253F3St8W1 EMNLIIN4EBI¢(�ABIPom HOUSE �aaiiiy ADULT FAMILY HOME - REMODEL 9983 JACKSON ST YELM, WA W597 APP.vvea Dot. — 112-1-I' TU1. Jvh Clvss- R.f: �vi1