Loading...
Eagle Plaza PlansCEILING MOUNTED AUDIO/VISUAL SEE NOTE 2 CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 6'-8" (80") CEILING MOUNTED AUDIO/VISUAL SEE NOTE 3 MAX 30'-0" (360") CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 MAX 6'-0" (72") & MIN 5'-6" (66") TYP. 5'-0" (60") TYP. MAX 4'-0" (48") MIN 3'-6" (42") NOTES: 1.LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING (NOT ON BOTTOM OF STRUCTURAL MEMBERS), AND AS INDICATED IN NFPA 72. 2.LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR; AND AS INDICATED IN NFPA 72. 3.LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING; ALIGNED WITH LIGHTING, SPRINKLERS, AND OTHER ARCHITECTURAL FIXTURES; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET A.F.F. ; AND AS INDICATED IN NFPA 72. 4.LOCATE WALL MOUNTED NOTIFICATION DEVICES AT 80" A.F.F TO BOTTOM OF BACK BOX. 5.COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS, ANNUNCIATORS, AND POWER SUPPLIES WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. 6.MEASURED TO THE OPERABLE PART OF THE PULL STATION. FAA WALL MOUNTED AUDIO/VISUAL PULL STATION FACU FAPS B2 A,B ###cd A 6,705 FT2 ANN F FIRE ALARM ANNUNCIATOR - XXcd WP 7067 EOL 77-FACPA FAPS LF BUILDING DATA ADDRESS:937 Yelm Ave W, Yelm, WA 98597 PARCEL #: AREA: TYPE OF CONST: OCCUPANCY: 45170000400 TYPE V-B B FireTek Design & Installation FIRE ALARM CONTROL UNIT - SK-6700 FIRE ALARM POWER SUPPLY - AES 24V POWER CONVERSION MODULE AES INTELLITAP DIALER FOR RADIO MANUAL PULL STATION - SK-PULL-SA SMOKE DETECTOR - SK-PHOTO-W DUCT SMOKE DETECTOR - CEILING MOUNT STROBE - SCRLED CEILING MOUNT HORN STROBE - PC2RLED WALL MOUNT STROBE - SRLED WALL MOUNT LOW FREQUENCY HORN - INDICATES RELOCATED DEVICES INDICATES WEATHER RESISTANT DEVICES INDICATES CANDELA RATING OF STROBE LIGHT DENOTES END OF CIRCUIT FOR THAT NAC LOOP 1 0 0 0 0 1 1 0 3 4 0 0 INDICATES THE CANDELA SETTING OF THE STROBE. INDICATES 1x OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE WIRE TYPE, IN THE WIRE LEGEND. INDICATES 1x EACH OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE WIRE TYPE, IN THE WIRE LEGEND. INDICATES 2 OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE TYPE, THE EXPONENT IS THE QUANTITY OF THAT WIRE. DESCRIPTION WIRE LEGEND SYMBOLS SEE NOTE 6 SEE NOTE 5 SEE NOTE 4 SUSPENDED CEILING SEE NOTE 5 FINISHED FLOOR TYPICAL DEVICE MOUNTING HEIGHT CEILING/DECK SYMBOL LEGEND RUNNER SERVICE PROVIDED BY MONITORING SERVICE PROVIDED BY: FireTek Design & Installation M C T MONITOR MODULE - CONTROL MODULE - IDP-CONTROL SPRINKLER TAMPER CONNECTION 0 0 HEAT DETECTOR -0 0 THE PURPOSE OF THIS DESIGN IS TO PROVIDE OCCUPANT NOTIFICATION UPON THE ACTIVATION OF THE DETECTION DEVICES. THE SCOPE OF THIS PROJECT IS EXTENDING THE EXISTING AUTOMATIC FIRE ALARM SYSTEM TO 2 NEW PORTABLES. AMBIENT SOUND PRESSURE LEVELS ARE SPECIFIED IN TABLE A.18.3.2 FROM NFPA 72 2013 HANDBOOK. ANTICIPATED AUDIBILITY IS FIGURED BY THE "6DB RULE OF THUMB" METHOD REFERENCED IN NFPA 72 2013 HANDBOOK. DESIGN NARRATIVE SHEET INDEX SHEET NUMBER DISCRIPTION FA01 PROJECT DETAILS FA02 FIRE ALARM DEVICE AND WIRE LAYOUT WIRE USE WIRE LEGEND TYPE DESCRIPTION C SBUS CIRCUIT 18 GAUGE 4 CONDUCTOR - FPLP DATA CIRCUIT TO ANNUNCIATOR A SLC CIRCUIT 18 GAUGE 2 CONDUCTOR - FPLP DATA CIRCUIT TO SMOKE/HEAT DETECTORS, AND PULL STATIONS 500 Cherry St SE Olympia, WA 98501 (360)353-3157 500 Cherry St SE Olympia, WA 98501 (360)353-3157 FACP D NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLP NOTIFICATION CIRCUIT TO STROBES/HORN STROBES NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLP NOTIFICATION CIRCUIT TO STROBES/HORN STROBES B RELO 0 1 1WALL MOUNT WEATHER RESISTANT HORN STROBE - P2RK(WP) H W SPRINKLER WATERFLOW CONNECTION 0 ATTIC HEAT DETECTOR - 0 0WALL MOUNT HORN STROBE - E NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLP NOTIFICATION CIRCUIT TO STROBES/HORN STROBES F NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLP NOTIFICATION CIRCUIT TO STROBES/HORN STROBES FUNCTION 4 KEY FUNCTION 3 KEY FUNCTION 2 KEY FUNCTION 1 KEY DRILL BUTTON AC / BATTERY NOTIFICATION CIRCUIT DEVICE OR MODULE SYSTEM COMPONENT HVAC SUPERVISORY CONDITIONS SPRINKER SUPERVISORY SWITCHES PULLSTATION SMOKE DETECTOR WATERFLOW SWITCH AL A R M L E D A C T I V A T E S SU P E R V I S O R Y L E D A C T I V A T E S TR O U B L E L E D A C T I V A T E S PI E Z O A C T I V A T E S AL A R M W I T H P O I N T I D T R A N S M I T T E D SU P . W I T H P O I N T I D T R A N S M I T T E D TR O U B L E W I T H P O I N T I D T R A N S M I T T E D GE N E R A L A L A R M N O T I F I C A T I O N EX T E R I O R S T R O B E O N L Y WA T E R F L O W B E L L HV A C S H U T D O W N FI R E D A M P E R S C L O S E INPUT DEVICES OR ACTIONS (TYP) OU T P U T D E V I C E S O R A C T I O N S (T Y P ) ALARM INITIATING DEVICES FACP DISPLAY / KEYPAD AU X I L I A R Y C O N T R O L S NO T I F I C A T I O N C I R C U I T S AE S C O M M U N I C A T O R FA C P F A R A P D I S P L A Y SUPERVISORY INITIATING DEVICES TROUBLE CONDITIONS FA01 Sheet Number Pr o j e c t N a m e : Da t e : Dr a w n B y : Em a i l : Jo b # : Fi l e N a m e : DW G N a m e : Pl o t D a t e : Ve r s i o n : Re v : Da t e : De s c r i p t i o n : BM I BR A Y D E N @ F I R E T E K O L Y M P I A . C O M Au t o C A D L T 2 0 2 4 FA _ E a g l e P l a z a 10 / 0 2 / 2 0 2 4 Ea g l e P l a z a 93 7 Y e l m A v e W Ye l m , W A 9 8 5 9 7 FA - E a g l e P l a z a 10 / 0 2 / 2 0 2 4 xx x x x x CAFE WORKROOM RESTROOM VEST. RESTROOM 1 RESTROOM 2 ENGINE DRIVE-THRU FACP EOL F 15cd 15cd 30cd 75cd 30cd 177cd 177cd M98:S001 M98:M001 A A C C C C C2C C C C2 177cd WP M Install 5 SK-MONITOR Modules for connection to the sprinkler system. Address points M98:M002 - M98:M006 A FA02 Sheet Number Pr o j e c t N a m e : Da t e : Dr a w n B y : Em a i l : Jo b # : Fi l e N a m e : DW G N a m e : Pl o t D a t e : Ve r s i o n : Re v : Da t e : De s c r i p t i o n : Au t o C A D L T 2 0 2 4 BM I BR A Y D E N @ F I R E T E K O L Y M P I A . C O M Fire Alarm Device and Wiring Layout 0 2'4'8' SCALE: 1/8"=1'-0"(IN FEET) FA _ E a g l e P l a z a 10 / 0 2 / 2 0 2 4 Ea g l e P l a z a 93 7 Y e l m A v e W Ye l m , W A 9 8 5 9 7 FA - E a g l e P l a z a 10 / 0 2 / 2 0 2 4 xx x x x x