24041 Masonry Cafe CMU Wall Repair - Structural Permit Set (2024-03-29)AREA DESIGN DEAD LOAD LIVE LOAD (2)PARTITION LOAD CONCENTRATED LOADS ROOF 25 PSF (1) THESE GENERAL NOTES ARE TO BE USED AS A SUPPLEMENT TO THE SPECIFICATIONS. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATIONS, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO JOB SITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY SHORING, FORMWORK, BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. PROVIDE ADEQUATE RESISTANCE TO LOADS ON THE STRUCTURES DURING CONSTRUCTION PER SEI/ASCE STANDARD NO. 37-14 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION." CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH DESIGN ASPECTS ONLY AND IS NOT INTENDED IN ANY WAY TO REVIEW THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2021 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. CONTRACT DRAWINGS / DIMENSIONS ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. CONSULTANT DRAWINGS BY OTHER DISCIPLINES ARE SUPPLEMENTARY TO ARCHITECTURAL DRAW INGS. REPORT DIMENSIONAL OMISSIONS OR DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND STRUCTURAL, MECHANICAL, ELECTRICAL OR CIVIL DRAWINGS TO ARCHITECT PRIOR TO PROCEEDING WITH WORK. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS. PRIMARY STRUCTURAL ELEMENTS ARE DIMENSIONED ON STRUCTURAL PLANS AND DETAILS AND OVERALL LAYOUT OF STRUCTURAL PORTION OF WORK. SOME SECONDARY ELEMENTS ARE NOT DIMENSIONED, SUCH AS WALL CONFIGURATIONS, INCLUDING EXACT DOOR AND WINDOW LOCATIONS, ALCOVES, SLAB SLOPES AND DEPRESSIONS, CURBS, ETC. VERTICAL DIMENSIONAL CONTROL IS DEFINED BY ARCHITECTURAL WALL SECTIONS AND BUILDING SECTIONS. STRUCTURAL DETAILS SHOW DIMENSIONAL RELATIONSHIPS TO CONTROL DIMENSIONS DEFINED BY ARCHITECTURAL DRAWINGS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH ARCHITECTURAL AND STRUCTURAL DRAWINGS. VERTICAL LOADS LATERAL FORCES LATERAL FORCES ARE TRANSMITTED BY DIAPHRAGM ACTION OF ROOF AND FLOORS TO SHEAR WALLS. LOADS ARE THEN TRANSFERRED TO FOUNDATION BY SHEAR WALL ACTION WHERE ULTIMATE DISPLACEMENT IS RESISTED BY PASSIVE PRESSURE OF EARTH AND/OR SLIDING FRICTION. OVERTURNING IS RESISTED BY DEAD LOAD OF THE STRUCTURE. WIND: THE BUILDING MEETS THE CRITERIA TO USE THE "ENCLOSED, PARTIALLY ENCLOSED, AND OPEN BUILDING OF ALL HEIGHTS PROCEDURE" PER ASCE 7-16. - EXPOSURE CATEGORY = B - BASIC WIND SPEED, (3 SEC. GUST), VULT = 100 MPH; VASD = 80 MPH - RISK CATEGORY PER IBC TABLE 1604.5 = - TOPOGRAPHIC FACTOR KZT = 1.00 - INTERNAL PRESSURE COEFFICIENT (ENCLOSED) = ± 0.18 SEISMIC IMPORTANCE FACTOR, e = 1.0 RISK CATEGORY OF BUILDING PER IBC TABLE 1604.5 = II SPECTRAL RESPONSE ACCELERATIONS SS = 1.288 & S1 = 0.465 SITE CLASS PER TABLE 20.3-1 = D (DEFAULT) DESIGN SPECTRAL RESPONSE ACCELERATIONS SDS = 1.03 & SD1 = N/A SEISMIC DESIGN CATEGORY = D I SEISMIC:(ASCE 7-16) Fp = 0.4SDS e GENERAL NOTES DESIGN CRITERIA EXISTING BUILDING STRUCTURAL SCOPE OF WORK THE STRUCTURAL SCOPE OF WORK FOR THIS PROJECT IS LIMITED SOLELY TO ADDRESSING THE DAMAGE TO THE EXTERIOR MASONRY WALLS DUE TO THE IMPACT OF A VEHICLE. THE DAMAGE HAS BEEN PREVIOUSLY ASSESSED IN A REPORT DATED 10/19/2023, PREPARED BY PCS STRUCTURAL SOLUTIONS, AND NOTES THAT THE STRUCTURAL DAMAGE WAS LIMITED TO THE NORTH WALL OVER THE FULL WIDTH OF THE BUILDING AND ALONG THE WEST WALL BACK TO THE FACE OF THE ADJACENT BUILDING TO THE WEST. THE NEW CMU WALLS WILL BE REINFORCED AND WILL COMPLY WITH THE 2021 IBC IN REGARDS TO OUT OF PLANE AND VERTICAL LOADS. ANCHORAGE IS PROVIDED TO THE EXISTING DIAPHRAGM WITHOUT IMPROVEMENT TO THE EXISTING ROOF. 300#20 PSF II I MASONRY ASSEMBLIES: SHALL BE CONSTRUCTED IN COMPLIANCE WITH THE REQUIREMENTS IBC CHAPTER 21, AND SHALL BE TESTED PER SECTION 2105.1 FOR COMPLIANCE WITH f'm. MINIMUM SPECIFIED COMPRESSIVE STRENGTH, f'm, SHALL BE 2000 PSI FOR CONCRETE MASONRY ASSEMBLIES AND 2500 PSI FOR HOLLOW CLAY MASONRY ASSEMBLIES. HOLLOW CONCRETE MASONRY UNITS (CMU): SHALL CONFORM TO ASTM C90. MINIMUM FACE SHELL THICKNESS AS DEFINED BY ASTM C90, SECTION 5.3.1. PROVIDE GRADE N, MEDIUM WEIGHT BLOCK WITH MINIMUM SPECIFIED COMPRESSIVE STRENGTH AS NOTED ABOVE. CMU CONSTRUCTION SHALL BE SOLID GROUTED UNLESS NOTED OTHERWISE. MASONRY POST-INSTALLED ANCHORS: SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER PRIOR TO INSTALLING POST- INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS W ITH REBAR. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. INSTALLER SHALL BE QUALIFIED AND TRAINED BY THE MANUFACTURER. HOLES SHALL BE HAMMER DRILLED ONLY (ROTARY DRILLED ONLY AT UNREINFORCED MASONRY - NO HAMMER TOOLS). SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED FOR APPROVAL A MINIMUM OF 2 WEEKS PRIOR TO BID, ALONG W ITH CALCULATIONS THAT SHALL BE STAMPED BY A PROFESSIONAL ENGINEER (LICENSED IN THE STATE OF THE PROJECT) DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE. POST-INSTALLED ANCHORS CONCRETE ANCHORS: - ADHESIVE ANCHORS: HILTI HIT-HY 200 V3 (ICC-ESR-4868), HILTI HIT-RE 500 V3 (ICC-ESR-3814), DEWALT PURE 110+ (ICC-ESR-3298) OR SIMPSON SET-3G (ICC-ESR-4057) OR PRE-APPROVED EQUAL. *CONCRETE SHALL BE A MINIMUM OF 21 DAYS OLD AT TIME OF INSTALLATION. *CONCRETE SHALL BE IN THE TEMPERATURE RANGE AS REQUIRED BY THE CONCRETE MANUFACTURER. *HOLE SHALL BY HAMMER-DRILLED ONLY. *DO NOT INSTALL IN WATER-FILLED HOLES. *INSTALLER OF HORIZONTAL OR UPWARDLY INCLINED (ANY POSITION EXCEPT DIRECTLY DOWNWARD) ANCHORS SHALL ALSO BE CERTIFIED BY THE ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM. - EXPANSION ANCHORS: KWIKBOLT TZ2 (ICC ESR-4266) BY HILTI, INC., OR PRE-APPROVED EQUAL. - SCREW ANCHORS: KWIK HUS-EZ (ICC ESR-3027) BY HILTI, INC., OR PRE-APPROVED EQUAL. MASONRY ANCHORS (SOLID GROUTED MASONRY): - ADHESIVE ANCHORS: HILTI HIT-HY 270 (ICC-ESR-4143) OR PRE-APPROVED EQUAL. - EXPANSION ANCHORS: KWIKBOLT III (ICC ESR-1385) BY HILTI, INC. OR PRE-APPROVED EQUAL. - SCREW ANCHORS: KWIK HUS-EZ (ICC ESR-3056) BY HILTI, INC. OR PRE-APPROVED EQUAL. MASONRY ANCHORS (HOLLOW MASONRY): - ADHESIVE ANCHORS: HILTI HIT-HY 270 WITH SCREEN TUBES AT HOLLOW CMU & UNREINFORCED BRICK MASONRY (ICC-ESR-4143 & ICC-ESR-4144) BY HILTI, INC. OR PRE-APPROVED EQUAL USING THE APPROPRIATE SIZE SCREEN TUBE REQUIRED BY THE MANUFACTURER. MINIMUM LAP SPLICE LENGTHS "Ld" FOR TYPICAL CONDITIONS (1) BAR SIZE CORNER BARS FOUNDATION DOWELS (3) VERTICAL WALL REINFORCING HORIZONTAL WALL REINFORCING LONG. LINTEL REINFORCING #3 12" 12" 12" 12" 12" #4 20" 20" 20" 20" 20" #5 30" 30" 30" 30" 30" #6 40" 40" 54" 40" 60" #7 46" 46"(2)46" (2) #8 60" 60"(2)60" (2) MORTAR IN STRUCTURAL WALLS: SHALL BE TYPE S PER THE IBC. CONFORM TO ASTM C270. MINIMUM COMPRESSIVE STRENGTH = 1800 PSI. GROUT: GROUT FOR POURING SHALL BE A FLUID CONSISTENCY. CONFORM TO ASTM C476 AND TMS 402. f'g=2500 PSI MINIMUM AT 28 DAYS. GROUT SHALL BE CONSOLIDATED BY MECHANICAL VIBRATION DURING PLACEMENT AND BEFORE LOSS OF PLASTICITY IN A MANNER TO FILL THE GROUT SPACE. GROUT POURS GREATER THAN 12 INCHES SHALL BE RECONSOLIDATED BY MECHANICAL VIBRATION 15 TO 20 MINUTES AFTER PLACEMENT TO MINIMIZE VOIDS DUE TO WATER LOSS. GROUT POURS 12 INCHES OR LESS IN HEIGHT SHALL BE MECHANICALLY VIBRATED, OR PUDDLED. COVER AND KEEP DRY ALL MASONRY WORK DURING CONSTRUCTION AND PREVENT MOISTURE ABSORPTION INTO MASONRY UNTIL THE ROOFING IS COMPLETE. REQUIREMENTS FOR ALL-WEATHER MASONRY CONSTRUCTION: HOT AND COLD WEATHER CONSTRUCTION REQUIREMENTS SHALL BE IN ACCORDANCE WITH TMS 602 "SPECIFICATION FOR MASONRY STRUCTURES", ARTICLES 1.8C AND 1.8D. REINFORCING STEEL (MASONRY): REINFORCING SHALL CONFORM TO ASTM A615, GRADE 60 (GRADE A706 FOR WELDED BARS UNLESS NOTED OTHERWISE). DETAIL, FABRICATE AND PLACE PER ACI 315 AND ACI 318. SPLICES SHALL BE AS NOTED BELOW. (1) FOR SPECIAL SPLICE CONDITIONS, REFER TO STRUCTURAL DRAWINGS FOR LAP LENGTH REQUIREMENTS. (2) MECHANICAL COUPLERS ARE REQUIRED. (3) FOR LAP SPLICES OF FOUNDATION DOWELS IN CANTILEVERED WALLS, USE LAP SPLICE LENGTHS FOR VERTICAL WALL REINFORCING. VERTICAL BAR POSITIONERS: VERTICAL REINFORCING SHALL BE SECURED AGAINST DISPLACEMENT PRIOR TO GROUTING BY "FIGURE 8" VERTICAL BAR POSITIONERS FOR SINGLY AND DOUBLY REINFORCED CELLS BY WIRE-BOND OR PRE-APPROVED EQUAL. LAP SPLICE SUBSTITUTION: REDUCTION IN MASONRY REINFORCEMENT LAP SPLICES ARE PERMITTED PER TMS 402 SECTION 6.1.6.1.1.2 WITH ADDITIONAL CONFINEMENT REINFORCEMENT AS A SUBSTITUTION TO SPECIFIED LAP SPLICES. A REINFORCEMENT PROPOSAL SHALL BE SUBMITTED FOR APPROVAL PRIOR TO BID AND INCLUDE SKETCHES OF REINFORCEMENT PATTERN TO JUSTIFY LAP SPLICE REDUCTION AND SHALL BE STAMPED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF THE PROJECT. STRUCTURAL STEEL MATERIAL PROPERTIES SHAPES AND PLATES: ASTM A36 (Fy = 36 KSI) TYP. U.N.O.; ASTM A572 (Fy = 50 KSI) WHERE INDICATED MACHINE BOLTS (M.B.): ASTM A307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE, ASTM F1554, GRADE 105 WHERE INDICATED. ADHESIVE ANCHOR RODS: FULLY THREADED ASTM F1554, GRADE 36 UNLESS NOTED OTHERWISE. PENNYWEIGHT DIAMETER (INCHES)LENGTH (INCHES) 8d 10d 16d 20d 0.131 0.148 0.148 0.192 2-1/2 3 3-1/2 4 ALL NAILS AND STAPLES SHALL CONFORM TO ASTM F1667 INCLUDING SUPPLEMENT 1. FOR DIAPHRAGM OR SHEAR WALL NAILING THE FOLLOWING FASTENER TYPES MAY BE USED AT EQUIVALENT SPACING TO THAT SPECIFIED ON PLANS. CARPENTRY: NAILS: CONNECTION DESIGNS ARE BASED ON NAILS WITH THE FOLLOWING PROPERTIES: FASTENER TYPE DIAMETER (INCHES) LENGTH (INCHES) 8d COMMON WIRE 0.131 62-1/2 EQUIVALENT SPACING (INCHES) 4 3 8d "DIPPED GALV. BOX"0.131 62-1/2 4 3 8d COOLER 0.113 4-1/22-1/2 3 2-1/2 14 GA. STAPLES 0.080 61-1/2*4 3 16 GA. STAPLES 0.062 41-1/2*3 - 10d COMMON WIRE 0.148 63 4 3 10d "HOT DIPPED GALV. BOX"0.148 63 4 3 10d "SHINY BOX"0.131 4-1/23 3 2-1/4 16d COMMON WIRE 0.162 63-1/2 4 3 16d SINKER NAIL 0.148 53-1/4 3-1/4 2-1/2 * BASED ON 15/32" PLYWOOD OR OSB. WOOD SHEATHING (STRUCTURAL): SHEATHING ON ROOF SURFACES SHALL BE PLYWOOD ONLY. SHEATHING ON FLOOR AND WALLS SHALL BE PLYWOOD OR ORIENTED STRAND BOARD (OSB). PLYWOOD SHEATHING SHALL BE 5-PLY MINIMUM WHERE INDICATED AS PERFORMANCE CATEGORY 3/4" OR THICKER. WOOD SHEATHING SHALL BE "STRUCTURAL I" CONFORMING TO PS1-09 AND/OR PS2-10. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF FRAMING AT 32"O.C. (48/24); ROOF FRAMING AT 24"O.C. (32/16); WALLS (32/16); FLOORS (48/24) ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GENERAL REQUIREMENTS: PROVIDE MINIMUM NAILING PER IBC TABLE 2304.10.1 OR MORE, AS OTHERWISE SHOWN. STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED W ITH THE EXCEPTION OF INTERIOR CONCRETE TOPPINGS ON WOOD FLOOR SYSTEMS. HOLES AND CUTS IN 3x OR 4x PLATES SHOULD BE TREATED WITH A 9% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3"x3"x0.229" PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED BY IBC SECTIONS 2308.4.2.4, 2308.5.9, 2308.5.10 AND 2308.7.4 OR AS RESTRICTED BY PLANS OR DETAILS, OR AS APPROVED PRIOR TO INSTALLATION. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. FRAMING CONNECTORS: SHALL CONFORM TO CURRENT EVALUATION REPORT AND BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN LEANDRO, CA., OR PRE-APPROVED EQUAL. PROVIDE MAXIMUM SIZE AND QUANTITY OF NAILS OR BOLTS PER MANUFACTURER, EXCEPT AS NOTED OTHERWISE. PROVIDE LEAD HOLES AS REQUIRED TO PREVENT SPLITTING OF WOOD MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. APPLICATION SPECIFIED MATERIAL PRESERVATIVE TREATMENT (1) CONNECTORS & FASTENERS (2)(3) EX P O S U R E DR Y FOUNDATION SILL PLATES, TOP PLATES & LEDGERS ON CONCRETE OR MASONRY WALLS (4) 2x, 4x, 6x (FIR), OR GLULAM (SP) SBX GALV (G60) ACQ, CBA, CA GALV (G185) WE T FRAMING, DECKING, POSTS & LEDGERS 2x, & 4x (FIR)ACQ, CBA, CA GALV (G185) 2x, & 4x (CEDAR) NONE GALV (G90) BEAMS & COLUMNS 6x (FIR), OR GLULAM (SP) ACQ, CBA, CA GALV (G185) 6x OR GLULAM (CEDAR) NONE GALV (G90) 1. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED FIR: DOUG-FIR OR HEM-FIR SBX: DOT SODIUM BORATE SP: SOUTHERN PINE ACQ: ALKALINE COPPER QUAT CBA & CA: COPPER AZOLE 2. CONNECTORS: JOIST HANGERS, STRAPS, FRAMING CONNECTORS, COLUMN CAPS AND BASES, ETC. FASTENERS: MACHINE BOLTS, ANCHOR BOLTS AND LAG SCREWS WITH ASSOCIATED PLATE WASHERS AND NUTS. NAILS, SPIKES, WOOD SCREWS, ETC. 3. G60, G90 & G185 PER ASTM A653 FOR COLD-FORMED STEEL CONNECTORS. BATCH/POST HOT-DIP GALVANIZED PER ASTM A123 FOR CONNECTORS AND ASTM A153 STRUCTURAL STEEL CONNECTORS. HOT-DIP GALVANIZED PER ASTM A153 FOR FASTENERS OR MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. 4. AT CONTRACTORS OPTION, LEDGERS AND TOP PLATES A MINIMUM OF 8 FEET ABOVE GRADE ON CONCRETE OR MASONRY WALLS MAY BE UN-TREATED IF COMPLETELY SEPARATED FROM THE WALL BY A SELF ADHERING ICE & WATER SHIELD BARRIER (40 MIL MINIMUM). PRESERVATIVE TREATED WOOD REQUIREMENTS: TREATMENTS OTHER THAN THOSE LISTED BELOW ARE NOT PERMITTED. FRAMING LUMBER: STANDARDS. EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BY THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) 1. 6x BEAMS AND HEADERS. "DOUG FIR-LARCH" NO. 1 (Fb=1350 PSI, Fv=170 PSI) 2. 2x TO 4x JOISTS, PURLINS AND HEADERS. "DOUG FIR-LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 3. 6x POSTS AND COLUMNS. "DOUG FIR-LARCH" NO. 1 (Fc=1000 PSI) 4. EXTERIOR STUDS, INTERIOR BEARING WALLS AND 4x COLUMNS. "DOUG FIR-LARCH" NO. 2 (Fb= 900 PSI, Fc= 1350 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI). 5. INTERIOR NON-BEARING STUD WALLS. "DOUG FIR-LARCH" NO. 2 (Fb=900 PSI. Fc=1350 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI) 6. 2x & 3x T&G DECKING: "DOUG FIR-LARCH" COMMERCIAL (Fb=1450 PSI, E=1700 KSI) 7. THE MINIMUM GRADE OF ALL OTHER STRUCTURAL FRAMING. "DOUG FIR-LARCH" NO. 2 (Fb= 900 PSI, Fc=1350 PSI), OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI). 8. UTILITY & STANDARD GRADES NOT PERMITTED. STRUCTURAL ENGR.BLDG. DEPT. 1. 2. MASONRY WALL REINFORCING DRAWINGS X X SHOP DRAWINGS/SUBMITTALS THE FOLLOWING SHOP DRAWINGS/SUBMITTALS SHALL BE PROVIDED FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO FABRICATION OR DELIVERY. MISCELLANEOUS: PRE-APPROVED SUBSTITUTIONS: SUBSTITUTIONS MAY BE ALLOW ED ONLY IF THEY MEET THE REQUIREMENTS OF THESE GENERAL NOTES AND THE SPECIFICATIONS, AND IF COMPLETE WRITTEN ENGINEERING DATA FOR EACH CONDITION REQUIRED FOR THIS PROJECT IS PROVIDED TO THE STRUCTURAL ENGINEER TWO WEEKS PRIOR TO BID DATE AND APPROVED IN WRITTEN ADDENDA BY THE ARCHITECT. DATA IS TO INDICATE CODE BASIS BY YEAR, AUTHORITY FOR STRESSES AND STRESS INCREASES, IF ANY, AND AMOUNT OF EXPECTED DEFLECTION FOR FLEXURAL MEMBERS UNDER (1) TOTAL LOAD AND (2) LIVE LOAD ONLY. ALL INCREASED COSTS IN MECHANICAL, SPRINKLER, ELECTRICAL OR GENERAL INSTALLATION AND ANY ARCHITECTURAL OR STRUCTURAL REDESIGN RESULTING FROM SUBSTITUTION SHALL BE BORNE BY THE GENERAL CONTRACTOR. CONTRACTOR'S STATEMENT OF RESPONSIBILITY X X 33519OX R EB MT DA D A L EOIN E E E P R F O S S GN NI R GTATSN O T AFOE W N IHS U T S R RA T C U L N NE G EE R I SHEET TITLE REVISION JOB # DRAWN DATE CHECKED PROJECT STAMP 3/ 2 9 / 2 0 2 4 1 2 : 0 2 : 2 6 PM C: \ _ R e v i t M o d e l s \ 2 4 0 4 1 M a s o n r y C a f e C M U W a l l R e p a i r R 2 0 2 2 ( C e n t r a l ) _ S O L E L S 1 9 6 5 . r v t S1.01 GENERAL NOTES MA S O N R Y C A F E R E P A I R S BAM BAM 3/29/2024 24-041 10 3 Y E L M A V E E YE L M , W A 9 8 5 9 7 PERMIT STRUCTURAL DRAWING INDEX SHEET NUMBER SHEET DESCRIPTION S1.01 GENERAL NOTES S1.02 GENERAL NOTES S2.01 FOUNDATION & ROOF FRAMING PLANS S3.01 DETAILS Grand total: 4 STATEMENT OF SPECIAL INSPECTIONS: SPECIAL INSPECTION: SPECIAL INSPECTION SHALL BE PROVIDED PER THE REQUIREMENTS OF IBC SECTION 1704 AND 1705 AND AS NOTED HEREIN. STRUCTURAL SYSTEM VERIFICATION AND INSPECTION CONTINUOUS PERIODIC COMMENTS REFERENCES MASONRY TMS 602, ART 2.4B, & 2.4H PROPORTION OF SITE-PREPARED MORTAR X TMS 602, ART 2.1, 2.6A & 2.6C GRADE, TYPE AND SIZE OF REINFORCEMENT, CONNECTORS AND ANCHOR BOLTS X TMS 602: ART 3.2D & 3.2FGROUT SPACE X PERIODIC INSPECTION PERMITTED FOR RISK CATEGORY I, II, AND III STRUCTURES TMS 402: SECT. 6.1, 6.3.1, 6.3.6 & 6.3.7, TMS 602: ART 3.2E & 3.4 PLACEMENT OF REINFORCEMENT, CONNECTORS AND ANCHOR BOLTS X PERIODIC INSPECTION PERMITTED FOR RISK CATEGORY I, II, AND III STRUCTURES TMS 602: ART 2.6B & 2.4G.1.bPROPORTIONS OF SITE-PREPARED GROUT X X TMS 602: ART 1.5MATERIALS AND PROCEDURES WITH THE APPROVED SUBMITTALS X TMS 602: ART 3.3BPLACEMENT OF MASONRY UNITS AND MORTAR JOINT CONSTRUCTION X TMS 602: ART 3.3FSIZE, TYPE AND LOCATION OF STRUCTURAL MEMBERS X TMS 402: SECT. 1.2.1(e), 6.2.1 & 6.3.1 TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION PERIODIC INSPECTION PERMITTED FOR RISK CATEGORY I, II, AND III STRUCTURESX TMS 602: ART 1.8C & 1.8DPREPARATION, CONSTRUCTION, AND PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE BELOW 40° F) OR HOT WEATHER (TEMPERATURE ABOVE 90°F) X PLACEMENT OF GROUT TMS 602: ART 3.5 & 3.6CX TMS 602: ART 1.4B.2.a.3, 1.4B.2.b.3, 1.4B.2.c.3, 1.4B.3 & 1.4B.4 OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS X PERIODIC INSPECTION PERMITTED FOR RISK CATEGORY I, II, AND III STRUCTURES POST INSTALLED ANCHORS INTO MASONRY X MFR EVAL REPORT SPECIAL INSPECTION: SPECIAL INSPECTION SHALL BE PROVIDED BY AN INDEPENDENT TESTING LABORATORY PER THE REQUIREMENTS OF IBC CHAPTER 17 AND THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION AND THE CONTRACT DOCUMENTS. THE SPECIAL INSPECTOR SHALL SUBMIT INSPECTION REPORTS AND A FINAL SIGNED REPORT TO THE BUILDING OFFICIAL FOR THE ITEMS LISTED IN THE QUALITY ASSURANCE/SPECIAL INSPECTION SECTION: TESTING AND SPECIAL INSPECTION REPORTS SHALL BE PREPARED FOR EACH INSPECTION ITEM ON A DAILY BASIS WHENEVER WORK IS PERFORMED ON THAT ITEM. REPORTS SHALL BE DISTRIBUTED TO OWNER, CONTRACTOR, BUILDING OFFICIAL, ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. STRUCTURAL OBSERVATIONS SHALL BE PERFORMED BY THE STRUCTURAL ENGINEER OF RECORD OR DESIGNATED REPRESENTATIVE IN ACCORDANCE WITH IBC 1704.6. STRUCTURAL OBSERVATION SHALL BE PERFORMED AS FOLLOWS: » PERIODIC VISUAL OBSERVATION OF STRUCTURAL SYSTEMS FOR GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS AT SIGNIFICANT CONSTRUCTION STAGES. » REVIEW OF TESTING AND INSPECTION REPORTS. » REPORTS SHALL BE PREPARED FOR EACH SITE VISIT AND SHALL BE DISTRIBUTED TO ARCHITECT. GENERAL CONTRACTOR SHALL SUBMIT A WRITTEN CONTRACTOR'S STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL INSPECTION REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTION. ABBREVIATION LIST HGR HANGER A.B.ANCHOR BOLT HDR HEADER A.F.F.ABOVE FINISH FLOOR HT HEIGHT ALT. ALTERNATE HORIZ.HORIZONTAL ARCH.ARCHITECTURAL HSS HOLLOW STRUCTURAL SECTION @ AT INT.INTERIOR BM BEAM JST JOIST BRG BEARING JT JOINT BTWN BETWEEN L ANGLE BLK'G BLOCKING LLH LONG LEG HORIZONTAL BOT.BOTTOM LLV LONG LEG VERTICAL B.O.F. BOTTOM OF FOOTING L.L.LIVE LOAD BLD'G BUILDING LOC.LOCATION B.U.BUILT UP LSL LAMINATED STRAND LUMBER (C= )CAMBER LVL CANT.CANTILEVER MAX.MAXIMUM C.J.CONTROL/CONSTRUCTION JOINT M.B.MACHINE BOLT MFR MANUFACTURER ± 20'-0" 3 S2.01 (E) CONC. STEM WALL AND FTG. 8" SOLID GROUTED CMU WALL MAINTAIN (E) CONC. SLAB AT DOORWAY (E) BLDG. (E) BLDG. ± 9 ' - 4 " ___ S3.01 2 ___ S3.01 3 1 S3.01 TYP. 3 S2.01 (E ) 2 x R O O F & CE I L I N G J O I S T S ___ S3.01 2 ___ S3.01 3 4 S3.01 5 S3.01 LEVEL 1 0" ROOF LEVEL 13'-4" 13 ' - 4 " ± 20'-0" 2'-0"9'-4"2'-8"3'-4" 8' - 8 " 2' - 0 " 33519OX R EB MT DA D A L EOIN E E E P R F O S S GN NI R GTATSN O T AFOE W N IHS U T S R RA T C U L N NE G EE R I SHEET TITLE REVISION JOB # DRAWN DATE CHECKED PROJECT STAMP 3/ 2 9 / 2 0 2 4 1 2 : 0 2 : 3 3 PM C: \ _ R e v i t M o d e l s \ 2 4 0 4 1 M a s o n r y C a f e C M U W a l l R e p a i r R 2 0 2 2 ( C e n t r a l ) _ S O L E L S 1 9 6 5 . r v t S2.01 FOUNDATION & ROOF FRAMING PLANS MA S O N R Y C A F E R E P A I R S BAM BAM 3/29/2024 24-041 10 3 Y E L M A V E E YE L M , W A 9 8 5 9 7 PERMIT 1/4" = 1'-0"S2.01 1 FOUNDATION PLAN 1/4" = 1'-0"S2.01 2 ROOF FRAMING PLAN 1/4" = 1'-0"S2.01 3 WALL ELEVATION 8" (E) CONC. STEM WALL AND FTG. (E) INT. CONC. SLAB ON GRADE 8" SOLID GROUTED CMU WALL (E) EXT. CONC. SIDEWALK #5 @ 32"O.C. W/ BARS AT ALL JAMBS & WALL CORNERS TYP. (2) #5 @ 32"O.C. HORIZ. W/ CONT. BARS AT SILLS/HEADS OF OPN'GS DRILL (E) STEM AND SET REINF. IN ADHESIVE 2 1 / 2 " 1'-6" (E) CMU WALL SET DOWEL IN ADHESIVE W/ SCREEN TUBE - SEE GEN. NOTES TYP. VERT. REINF. #4 DOWEL @ 32" O.C. TYP. HORIZ. REINF. SOLID GROUTED CMU WALL #4 x 1'-10" DOWEL @ 32" O.C. (E) CMU WALL SET DOWEL IN ADHESIVE W/ SCREEN TUBE - SEE GEN. NOTES TYP. VERT. REINF. TYP. HORIZ. REINF. SOLID GROUTED CMU WALL 2 1 / 2 " (E) 2x CEILING & ROOF JOISTS LTTP2 @ 48" O.C. (E) ROOF DECKING 10d @ 6" O.C. 3x TRT'D LEDGER TO MATCH (E) FRM'G DEPTH