Loading...
TwinStar CU combined Permit setA NEW SUPERMARKETBANK FOR: SAFEWAY #1619 1109 E YELM AVE YELM, WA 98597 SECTION 1704 SPECIAL INSPECTIONS SPECIAL INSPECTIONS FOR THIS PROJECT ARE NOT REQUIRED FOR WORK OF A MINOR NATURE OR AS WARRANTED BY CONDITIONS IN THE JURISDICTION AS APPROVED BY THE BUILDING OFFICIAL. (INTERNATIONAL BUILDING CODE, 2021 EDITION, CHAPTER 17, SECTION 1704 SPECIAL INSPECTIONS, SECTION 1704.2, EXCEPTION #1.) AND ANGLE (MATHEMATICAL) AT CENTERLINE DIAMETER PERPENDICULAR PARALLEL ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FLOOR APPROXIMATE BETWEEN CABINET CLOSET CEILING CLEAR COUNTER COLUMN CONSTRUCTION CONTINUOUS CENTER DOUBLE DETAIL DIAMETER DIMENSION DOOR OPENING DOOR DRAWER DRAWING ANGLE (STRUCTURAL) AUTOMATED LOAN MACHINE + MODEL # L @ í < ADJ. A.F. APROX. BET. CAB. CLO. CLG. CLR. CNTR. COL. CONSTR. CONT. CTR. DBL. DET. DIM D.O. DR. DWR. DWG. MACHINE + MODEL # AUTOMATED TELLER EA.EACH ELEVATION ELECTRICAL ENCLOSURE ELECTRICAL PANELBOARD EQUAL EQUIPMENT EXISTING EL. ELEC. ENCL. E.P. EQ. EQPT. EXIST. FAB.FABRIC FINISH FINISH OPENING FLUORESCENT GLASS GYPSUM WALL BOARD HARDWARE HORIZONTAL HEIGHT HEATING, VENTILATING, & AIR CONDITIONING EXPOSEDEXPO. FIN. F.O. FLUOR. GL. G.W.B. HDWR. HORIZ. HT. HVAC NUMBER# or NO. DIA. or ~ & or + JUNCTION BOX JOINT MAXIMUM JT. MAX. MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENING MOUNTED NOT IN CONTRACT MECH. MFR. MIN. MISC. M.O. MTD. MONEY SAFE/DEPOSITORY CHEST + MODEL # 'LOW-BOY' TELLER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OPENING PLASTIC LAMINATE CABINET GRADE PLYWOOD PROJECTION QUANTITY N.I.C. NOM. N.T.S. O.C. O.D. OPNG. P. LAM. PWD. PROJ. QTY. RADIUSRAD. NOT APPLICABLEN.A. MODEL # PEEPHOLE @ 62" A.F.PP.H. ROUGH OPENINGR.O. SHEET SIMILAR STANDARD STORAGE SUSPENDED SYMMETRICAL TELEPHONE THICK TYPICAL UNLESS OTHERWISE NOTED VERTICAL VERIFY IN FIELD VINYL COMPOSITION TILE WITH WOOD WITHOUT SHT. SIM. STD. STOR. SUSP. SYM. TEL. THK. TYP. U.O.N. VERT. V.I.F. V.C.T. W/ WD. W/O ABBREVIATIONS E.G.EXHAUST GRILLE S.A.SUPPLY AIR A.C.T. J-BOX INCAND.INCANDESCENT REVERSEREV. REC.RECESSED UNDER-COUNTER PEDESTAL + MODEL # NIGHT DEPOSITORY + 'UNDER-COUNTER' - TELLER UNDER-COUNTER PEDESTAL + MODEL # ALM XXX-X XXX-X ATM XXX-X MS XXX-X LB XXX-X ND XXX-X U.C. CL MON.MONITOR B/BOTTOM OF T/TOP OF OVERO/ O.P.C.I.OWNER PROVIDED, CONSTRUCTOR INSTALLED TO BE DETERMINEDT.B.D. T.S.TRANSACTION SURFACE W.S.WORK SURFACE COND.CONDUIT PLAN & DETAIL SYMBOLS ELEVATION TARGET EL. 0'-0" BUILDING OR WALL SECTION 1 01 DETAIL SHEET DETAIL REFERENCE 01 1 DETAIL SHEET CONSTRUCTION PLAN NOTE FINISH NUMBER 1 F1 1 WINDOW NUMBER DOOR NUMBER PROJECT DIRECTORY 1 DRAWING INDEX IBC BUILDING CODE CHAPTER 33 - SAFEGUARDS DURING CONSTRUCTION THE CONTRACTOR SHALL FOLLOW THE PROVISIONS OF CHAPTER 33 THAT GOVERN SAFETY DURING CONSTRUCTION AND THE PROTECTION OF ADJACENT PUBLIC AND PRIVATE PROPERTY. CONTRACTOR SHALL PROVIDE SEPARATION FROM OCCUPIED STORE AND ALTERED TENANT SPACE DURING CONSTRUCTION. CONSTRUCTION DOCUMENTS AND SCHEDULING SHALL BE SUBMITTED WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. PROFESSIONAL CERTIFICATION LOCATION PLAN THE INTENT OF THIS PROJECT IS AN INTERIOR RENOVATION OF A TENANT SPACE LOCATED AT SAFEWAY #1619, 1109 E YELM AVENUE, YELM, WA 98597. THE SPACE IS OCCUPIED BY TWINSTAR CREDIT UNION FOR THE PURPOSE OF BANKING. THE ARCHITECTURAL, LIFE SAFETY, ADA AND STRUCTURAL ELEMENTS OF THE EXISTING BUILDING WILL NOT BE CHANGED OR ALTERED. SCOPE OF WORK CORPORATE FINANCIAL INSTITUTION: DESIGNER: FINANCIAL SUPERMARKETS, INC. 383 CLARKESVILLE STREET P.O. BOX 1450 CORNELIA, GEORGIA 30531 CONTACT: RANDALL PHILLIPS PHONE: (785) 221-6040 EMAIL: rphillips@supermarketbank.com TWINSTAR CREDIT UNION 4501 INTELCO LOOP SE LACEY, WA 98503 CONTACT: ERIC KNIESTEDT PHONE: (360) 923-4549 EMAIL: ekniestedt@twinstarcu.com PROJECT MANAGER: WHITNEY DESIGN, INC. 1136 HUDSON DRIVE ATLANTA, GEORGIA 30306 CONTACT: JANEEN WHITNEY PHONE: (404) 872-4676 EMAIL: janeen@whtineydesigninc.com ARCHITECT: BCA STUDIOS - ARCHITECTS, P.C. 410 BRADFORD STREET NW GAINESVILLE, GEORGIA 30501 CONTACT: JEFFERY S. CROCKER PHONE: (470) 480-5560 EMAIL: jeff@bcamail.com GENERAL CONTRACTOR: VIACON, INC. 70 BANKS ROAD STOCKBRIDGE, GEORGIA 30281 CONTACT: RUSSELL VIA PHONE: (770) 507-9913 EXT. 418 FAX: (770) 507-9536 EMAIL: rvia@viaconinc.com DESIGN SUMMARY SAFEWAY #1619 1109 E YELM AVE. YELM, WA 98597 PROJECT ADDRESS CODE ANALYSIS EXISTING BUILDING PROPOSED ALTERATION IBC OCCUPANCY CLASSIFICATION MERCANTILE BUSINESS TYPE OF CONSTRUCTION IIB IIB NUMBER OF STORIES ABOVE GRADE 1 1 HIGH RISE NO NO COVERED MALL NO NO FIRE ALARM YES YES FULLY SPRINKLERED YES YES OVERALL BUILDING FLOOR SPACE 55,297 SF ... SPECIAL INSPECTIONS NORMAL CUSTOMER ACTIVITY OF EXISTING STORE. ALL WORK TO BE DONE IN A MANNER NOT TO INTERFERE WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES HAVING JURISDICTION. PROVIDING ALL MATERIALS AND WORK IN STRICT ACCORDANCE WITH MATERIALS ONLY. ELECTRICAL SUBCONTRACTOR IS RESPONSIBLE FOR ELECTRICAL PLAN SHOWS DESIGN INTENT AND QUANTITIES AND LOCATIONS OF 2.08 2.07 2.06 DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. IF DIMENSION IS UNCERTAIN, CONTACT DESIGNER BEFORE FABRICATION. WHERE NUMERIC ANGLES APPROXIMATE DIMENSIONS GIVEN FOR REFERENCE ONLY (E.G. +/- 2'-3"). ARE GIVEN ON THE CONSTRUCTION PLAN, THEY ARE EXACT. RELATED DRAWING NOTES COMPOSITION TILE TYPICAL). ALL VERTICAL DIMENSIONS SHOWN ARE TO FINISH FLOOR (EXISTING VINYL ACROSS VOIDS. "ALIGN" MEANS SIMILAR COMPONENTS OR CONSTRUCTION SHALL ALIGN OCCUR, AND ARE TYPICAL FOR ALL SIMILAR CONDITIONS THROUGHOUT. DETAILS ARE USUALLY KEYED ONLY ONCE, ON DRAWINGS WHERE THEY FIRST "TYPICAL" MEANS TYPICAL FOR ALL SIMILAR CONDITIONS. CONSTRUCTION NOTES 2.05 2.04 2.03 2.02 2.01 2 3.01 3 ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS. INSTALL ALL PREMANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT, IN STRICT PREMANUFACTURED ITEM NOTES 4 SCOPE AND ADMINISTRATION 4.01 CONTRACT ADMINISTRATION SERVICES FOR THIS PROJECT. BCA - STUDIOS ARCHITECTS WILL NOT PROVIDE SHEET CONTENTS ARCHITECTURAL G001 COVER SHEET, DRAWING INDEX, CODES G002 LIFE SAFETY PLAN 2.0 CONSTRUCTION PLAN AND NOTES, FINISHES 2.1 WALL PANEL & JOINT DETAILS, WINDOW & DOOR SCHEDULES 3.0 BRANCH SECTION & ELEVATIONS, MILLWORK ELEVATIONS 3.1 MILLWORK ELEVATIONS 4.0 MILLWORK SECTIONS & DETAILS, KEY & HARDWARE SCHEDULES 4.1 MILLWORK SECTIONS & DETAILS 5.0 REFLECTED CEILING PLAN SEISMIC CATEGORY D VICINITY MAP SECTION 508 IBC: 508.3.1 OCCUPANCY CLASSIFICATION: BANK: BUSINESS OCCUPANCY OCCUPANT LOAD: (TABLE 1004.5 IBC) BUSINESS: 150 GROSS 548 SF / 150 SF (PERSON) = 4 FLOOR AREA OF TENANT SPACE APPROX. 548 SF MECHANICAL AND ELECTRICAL: JUSTIN HARDY, P.E. GUIDO INOA ALVAREZ, P.E. 5014 KINGSBRIDGE PASS POWDER SPRINGS, GEORGIA 30127 CONTACT: JUSTIN HARDY PHONE: (678) 234-8156 EMAIL: justin@convergeengineers.com ORDINANCES HAVING JURISDICTION. WORK IN STRICT ACCORDANCE WITH APPLICABLE CODES, REGULATIONS, AND PLUMBING SUBCONTRACTOR RESPONSIBLE FOR PROVIDING ALL MATERIALS AND OF MATERIALS ONLY FOR MODIFICATION TO BASE BUILDING SPRINKLER SYSTEM. REFLECTED CEILING PLAN SHOWS DESIGN INTENT AND QUANTITIES AND LOCATIONS "PROFESSIONAL CERTIFICATION: I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF WASHINGTON, LICENSE #10718, EXPIRES 10/11/2026. APPLICABLE CODES MECHANICAL ELECTRICAL M1.0 MECHANICAL PLAN E1.0 ELECTRICAL POWER PLAN E2.0 ELECTRICAL LIGHTING PLAN FIRE PROTECTION FP1 FIRE PROTECTION PLAN SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I & II CONSTRUCTION 603.1 ALLOWABLE MATERIAL FIRE-RETARDENT-TREATED WOOD SHALL BE PERMITTED IN: NON BEARING PARTITIONS WHERE THE REQUIRED FIRE RESISTANCE RATING IS 2 HOURS OR LESS. ALL BUILDING WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, INCLUDING THE FOLLOWING CODES WHERE REQUIRED: 2021 INTERNATIONAL BUILDING CODE WITH STATE AMENDMENTS 2021 INTERNATIONAL RESIDENTIAL CODE WITH STATE AMENDMENTS 2021 INTERNATIONAL FUEL GAS CODE WITH STATE AMENDMENTS 2021 INTERNATIONAL MECHANICAL CODE WITH STATE AMENDMENTS 2021 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS 2023 NFPA 70 NATIONAL ELECTRICAL CODE WITH STATE AMENDMENTS 2021 INTERNATIONAL FIRE CODE WITH STATE AMENDMENTS 2021 INTERNATIONAL ENERGY CONSERVATION CODE WITH STATE AMENDMENTS 2017 ICC/ANSI A117.1 ACCESSIBLE BUILDINGS WITH STATE AMENDMENTS 2010 AMERICANS WITH DISABILITIES ACT (ADA) PERMIT IS SUBJECT TO FIELD INSPECTIONS AND CODE COMPLIANCE. (SEE SHEET 4.1 FOR SEISMIC CEILING APPLICATIONS GUIDE) ORGANIC SALES 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 G001 COVER SHEET, DRAWING INDEX, CODES SITE TWINSTAR CREDIT UNION SAFEWAY #1619 1109 E YELM AVE YELM, WA 98597 AREA OF WORK TWINSTAR CREDIT UNION 548 SQUARE FEET EXISTING SAFEWAY #1619 CONSTRUCTION TYPE: IIB UNPROTECTED SPRINKLERED APPROXIMATELY 55,297 SF EXIT TWINSTAR CREDIT UNION 548 SQ. FT. BUSINESS OCCUPANCY SPRINKLERED EXIT EXIT TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE BUSINESS OCCUPANCY WITH SPRINKLER SYSTEM: EXIT ACCESS TRAVEL DISTANCE: 300 FEET EXIT ACCESS TRAVEL DISTANCE TO EXTERIOR: 61' < 300' WOMEN'S COMMON RESTROOMS MEN'S COMMON RESTROOMS EXIT ACCESS TRAVEL DISTANCE TO EXTERIOR: 140' < 300' TABLE 1006.2.1 EXIT ACCESS TRAVEL DISTANCE WITH SPRINKLER SYSTEM: OCCUPANCY: B = 100 FEET DESIGNED TRAVEL DISTANCE: 22' < 100' DESIGNED OCCUPANT LOAD: 4 < 49 LOBBY OFFICE TRAVEL DISTANCE: 22 FEET TR A V E L D I S T A N C E : 1 5 F E E T TABLE 1017.2 ACCESS TRAVEL DISTANCE OCCUPANCY A, E, F-1, M, R, S-1 I-1 B F-2, S-2, U 200 200 300 H-1 H-2 H-3 H-4 H-5 I-2, I-3 I-4 150 NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED WITHOUT SPRINKLER SYSTEM (FEET) WITH SPRINKLER SYSTEM (FEET) NOT PERMITTED 250 250 300 400 75 100 150 175 200 200 200 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY OCCUPANCY MAXIMUM OCCUPANT LOAD OF SPACE A, E, M B F H-1, H-2, H-3 49 49 49 3 MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE (FEET) 75 100 75 NOT PERMITTED H-4, H-5 I-1, I-2, I-4 I-3 R-1 S U 10 10 10 10 29 49 100 100 WITHOUT SPRINKLER SYSTEM (FEET) OCCUPANT LOAD OL < 30 OL > 30 75 WITH SPRINKLER SYSTEM (FEET) R-2 R-3 R-4 10 10 10 75 NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED 75 75 75 75 75 NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED 75 75 100 100 25 75 75 100 75 125 125 125 100 EXISTING WALL EXIT WALL TYPES (SEE DETAIL 1, SHEET 2.1) EGRESS TRAVEL PATH DISTANCE NOTED IS ACTUAL DISTANCE TO EXIT ALLOWABLE EXIT ACCESS TRAVEL DISTANCE / CODE = 300' COMMON PATH OF TRAVEL / CODE = 100' SYMBOL LEGEND LIFE SAFETY LEGEND F.E. TENANT SPACE 548 SQUARE FEET OCCUPANCY CLASSIFICATION OCCUPANT LOAD:548 SF / 150 SF/PERSON BUSINESS 4 PERSONS 10'-6"EGRESS TRAVEL PATH DISTANCE WALL MOUNTED FIRE EXTINGUISHER PATH OF EGRESS TRAVEL 1 (1) HOUR RATED PARTITION - NOT APPLICABLE OCCUPANT LOAD (TABLE 1004.5 2021 IBC) 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 G002 LIFE SAFETY PLAN SCALE: 2 G002 1/4" = 1'-0" LIFE SAFETY PLAN COMMON PATH OF EGRESS TRAVEL SCALE: 1 G002 MEANS OF EGRESS 1" = 20'-0" SCALE: 1 2.0 CONSTRUCTION PLAN 1/2" = 1'-0" 1 3.0 LOBBY 10 1 POWER PANEL 2 ALARM PANELS INSIDE CABINETS ABOVE OFFICE 4 FT1 EXISTING SIGNAGE ON EXISTING BULKHEAD TO REMAIN 1 13 ATM DN 400 85" VIDEO DISPLAY (SAMSUNG QB85C) F2 CARPET TILE DIRECTION FULL HEIGHT CABINETS EXISTING WALL 3 1 L2 10 9 2 12 TCR VERTERA 6G 2 3.0 3 12 11 10"H CURBL1 5 CASH TRAY INSERT 2"40'-10" 3 4" 33 8"12'-05 8"6 3 16"27'-8 7 16"33 8" 6'-10"5'-25 8"2'-8 7 16"2'-1" 2" 12 ' - 3 1 4" 3 4" 338" 7' - 9 5 8" 4' - 2 1 4" 33 8"2'-8"8'-6" 3"6"3'-3"6"3'-3"6"3" 4'-8"8'-6" 3"6"3'-3"6"3'-3"6"3" 3'-715 16" 9" 1'- 4 " 9 5 16" 2 1 4"6"3'-9"2'-9" CLR. OPENING 3'-3"6"2'-9"6"6"2'-0"33 8"2" 11'-5"11'-6" 4' - 7 5 8" 3' - 2 " 3' - 3 " 3" 6" 3" 3' - 3 " 6" 3' - 3 " 6" 4'-1 1 2"1'-11"3'-10 1 2" 1'-10"3'-0"1'-10"1'-10"3'-0"1'-10"3'-0"1'-10"1'-10"3'-0"13 4" 1" 2" 2' - 1 1 " 1" 2" 2' - 1 1 " 4'-1 1 2"1'-11"3'-11 1 2" 3'-35 8" 1" 3' - 3 " 8" 6" 3' - 0 3 8" 338" 2"338" 5' - 9 1 4" 3" 8" 6' - 4 " 2" 338" 1' - 1 1 " 2' - 1 1 1 4" 2' - 8 " 2'-0"33 8"2'-0" 1'-4" 2'-6" 3' - 5 " 2' - 0 " 1' - 4 " 1'-4" 2'-10" 2' - 1 1 1 8" 2' - 1 0 1 4" 1' - 7 1 4" 3'-0" 3'-0 7 8 " R20'-3 3 16" 6" 81 2" 10 ' - 1 1 " 3'-8" 2' - 8 1 4" T Y P . O F 4 16 7777 886 4 8765 5 SAFE BELOW 12EQUIP RACK ABOVE 1 3.1 2 3.1 3 3.1 4 3.0 5 3.0 6 3.0 7 3.0 3 3.0 11 WB1 MM1 12 TCR VERTERA 6G FT1FT1FT2 5 CASH TRAY INSERT 5 CASH TRAY INSERT 5 CASH TRAY INSERT +30.5" A.F.F. +30.5" A.F.F. +36" A.F.F. +30.5" A.F.F. +36" A.F.F.+36" A.F.F.+36" A.F.F. +40.5" A.F.F. EXISTING COLUMN 14 14 14 14 14 1" 15151515 +40.5" A.F.F. L1 DECORATIVE HEADER ABOVE L2 L2 P1P1P1 L2 L2 L2 L2 WB1 P1 L1 L1 COLUMN L3 40"H LOW WALL L3 10"H CURBL1 10"H CURBL1 10"H CURBL1 L1 COLUMNL1 3" 6" 3" COLUMNL1 COLUMNL1 COLUMNL1 DECORATIVE BEAM ABOVE HEADER ABOVE HEADER ABOVE HEADER ABOVE DECORATIVE BEAM ABOVEL1 DECORATIVE BEAM ABOVE L1 DECORATIVE BEAM ABOVEL1 COLUMNL1 COLUMNL1 L2 F1 F1 F1 F1 MATCH EXISTING STORE VCT IN ATM ALCOVE REPLACE EXISTING STORE VCT TO MATCH EXISTING AS NEEDED OUTSIDE LEASE SPACE ALONG LEASE LINE TO REPAIR ANY EXISTING DAMAGE OR DAMAGE INCURRED DURING DEMOLITION OR CONSTRUCTION DECORATIVE BEAM ABOVE L1 OS-xTO CIRCUIT #1 TO CIRCUIT #2 DI M - y DI M - z 2 DIM-z1 TO CIRCUIT #1 TO CIRCUIT #1 TO DIMMER SWITCH z2 TO DIMMER SWITCH y 3'-0" CG1CG1 CG1 CG1 39'-0" HH1 6 TOTAL INSIDE 5" 8" 8" CUSTOM MILLWORK DESK PROVIDE 4" x 3/4" x 10'-0" LONG (TRIM LENGTH IN FIELD AS REQ'D) TRIM FINISHED ON FACE + 2 SIDES TO CLOSE GAP @ NEW/EXISTING CONSTRUCTION. ALARM PANELS INSIDE CABINETS ABOVE - SUPPLIED AND INSTALLED BY SECURITY EQUIPMENT INSTALLER (PROVIDE CONDUITS ONLY. SEE ELECTRICAL PLAN FOR CONDUIT SIZE AND LOCATION). POWER PANEL SUPPLIED BY FABRICATOR AND INSTALLED BY ELECTRICAL CONTRACTOR (PROVIDE R.O. W/ TOP @ 6'-0" A.F.F.) SEE ELECTRICAL PLAN FOR LOCATION. CONSTRUCTION PLAN NOTES 11 13 12 10 9 8 5 7 6 4 3 1 ATM - PROVIDED BY FINANCIAL INSTITUTION - F.S.I. TO COORDINATE INSTALLATION. 2 EQUIPMENT PROVIDED AND INSTALLED BY FINANCIAL INSTITUTION TEMPERED BUTT-JOINT 1/2" GLASS WITH PENCIL POLISHED EDGES. ALL EXPOSED EDGES ARE TO BE EASED AND SMOOTHED. ENSURE NO SHARP EDGES. GLASS EXTENDS FROM TOP OF LOW WALL OR CURB TO BOTTOM OF HEADER BEAM WITH STOPS AT TOP AND BOTTOM. SEE WINDOW SCHEDULE. WIRE CHASE IN WALL PANEL - SEE DETAIL SHEET 6.0 PRINTER WELL WITH 16"x16" OPENING IN COUNTERTOP TEMPERED 1/2" GLASS WITH PENCIL POLISHED EDGE AT TOP. ALL EXPOSED EDGES ARE TO BE EASED AND SMOOTHED. ENSURE NO SHARP EDGES. GLASS EXTENDS FROM TOP OF LOW WALL OR CURB TO HEIGHT INDICATED ON WINDOW SCHEDULE WITH STOP AT BOTTOM AND SIDES. TL-15 SAFE 26"W x 26"D x 26"H WITH CASH TRAYS PROVIDED AND INSTALLED BY F.S.I. ADA COMPLIANT TURNING SPACE (CIRCULAR OR T-SHAPED) 14 WALL WRAPS/NON-ILLUMINATED SIGNAGE PROVIDED AND INSTALLED BY FINANCIAL INSTITUTION - PROVIDE TYPICAL WALL PANEL REVEALS 15 YALE STYLE CABINET LOCKS CL2 AT TELLER CPU/COIN CABINETS 16 PROVIDE "HIDDEN" ACCESS DOOR WITH PUSH LATCH, FLUSH WITH SURROUNDING WALL, LAMINATED TO MATCH - SIZE AS REQUIRED TO ACCESS ELECTRICAL PANEL RECESSED IN WALL PANEL. PROVIDE ADA COMPLIANT "ELECTRICAL PANEL INSIDE" SIGN WITH TACTILE TEXT AND GRADE 2 BRAILLE ADHERED TO HIDDEN DOOR - ADASIGNDEPOT.COM ITEM #ADA-1229 WHITE-ON-BLACK TEMPERED 1/2" GLASS. GLASS EXTENDS FROM TOP OF LOW WALL OR CURB TO BOTTOM OF HEADER BEAM WITH STOPS AT ALL SIDES. SEE WINDOW SCHEDULE. EXACT LOCATION AND NUMBER OF FIRE EXTINGUISHER(S) TO BE DETERMINED BY AUTHORITY HAVING JURISDICTION.17 "VAPOR STRANDZ" FINISH SCHEDULE PLASTIC LAMINATE: L2 FINISH KEY L1 LOCATION #4939K-18 #5487-26 "OILED WALNUT" COLOR/NO. WILSONART MANUFACTURER FORMICA ACOUSTICAL CEILING TILECEILING:C1 24" x 24" x 3/4" SQUARE LAY-IN MESA TILES #680 IN PRELUDE EXPOSED TEE GRID, 15/16" GRID FACE, WHITE (WH) OR EQUAL ARMSTRONG CABINET FACES, TELLER KNEEWALL, HEADERS, CURBS, TELLER COLUMNS FULL HEIGHT WALLS EXCEPT ACCENT WALLS FLOOR:F1 MOHAWK BOLDER C0010 "PEBBLE" #925LUXURY VINYL TILE - LOBBY SS #757 "LUNA SAND"FORMICACOUNTERTOPS AND DESKTOPSSOLID SURFACE: F2 SHAW"EXPOSE" #26761CARPET TILE - OFFICE BASE MOULDING:B1 JOHNSONITERUBBER BASE 9"x36" ASHLAR DOOR HINGES, LEVER HANDLES, CABINET HANDLES, COVER & SWITCH PLATES HARDWARE:H1 #626 SATIN CHROME CHAIRSUPHOLSTERY FABRIC:U1 "EARL GREY" "SATIN STAINLESS"L3 #4830K-18 WILSONARTTELLER PARAPETS AND TOEKICKS, DOORS, LOW WALL, OFFICE COLUMN GLITCH TILE #5T128 P1 SHERWIN WILLIAMSPAINT: #38 PEWTER, 4.25"H "REVEAL" #MW-38-F "MILLWORK" WALL BASE TRIM TOP TO FIT UNDER TOEKICKS AS NEEDED HON MOXIE #SX40 #SW 6965 "HYPER BLUE"REAR WALL, ATM HEADER, LIGHT COVE ACCENTS 36"x36" MONOLITHIC FINISH NOTES 1. FABRICATOR TO SUPPLY ONE EXTRA SHEET OF EACH LAMINATE FABRICATOR TO SUPPLY COLOR MATCH CAULKING IN COLORS OF 2. 3. NECESSARY REPAIRS. EACH LAMINATE SPECIFIED TO BE TAKEN TO SITE AT INSTALLATION 4.FABRICATOR TO SUPPLY (4) 8'-0"x3-3/4" TRIM PIECES FINISHED ON 3 SIDES TO BE TAKEN TO SITE AT INSTALLATION FOR ANY FOR ANY NECESSARY REPAIRS. SPECIFIED TO BE TAKEN TO SITE AT INSTALLATION FOR ANY NECESSARY REPAIRS. 8'-0" PLYWOOD LAMINATED ON 2 EDGES & 1 SIDE. 5.TRIM FOR MISC. USE: PROVIDE (10) PIECES 3/4" x 2-1/2" x SEE REFLECTED CEILING PLAN. 2x2 WHITE ACOUSTICAL CEILING TILE, TYP. FLOORING SUBCONTRACTOR TO PROVIDE ZERO VOC ADHESIVES.6. WALL LEGEND EXISTING WALL NEW MILLWORK PARTITION 1 PARTITION TYPE (SEE DETAIL 1/2.1, SHEET 2.1 FOR PARTITION DETAILS) FIRE EXTINGUISHER (SEE NOTE 17 CONSTRUCTION PLAN NOTES) F.E. 1111 1 2 1 17 F.E. 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 2.0 CONSTRUCTION PLAN & NOTES, FINISHES SCALE: 1 2.1 PRE-ASSEMBLED COMPOSITE WALL PANEL 1" = 1'-0" FRAMING MATERIAL SHEATHING MATERIAL HIGH PRESSURE PLASTIC LAMINATE FLAME SPREAD: CLASS B TESTED IN ACCORDANCE WITH ASTM E-84 FINISH MATERIAL A B C WALL PANEL MATERIALS 0'-0" EXISTING CONCRETE SLAB J-BOX HT VARIES SEE ELECT. PLAN 18GA 1 4" WIDE X 1.25" LONG STAPLES USED TO ASSEMBLE PLYWOOD WALL PANEL FRAME & 'L'-SHAPED WALL BRACKET, TO ATTACH PLYWD SHEATHING TO FRAME IN SHOP YELLOW WOOD GLUE - ALIPHATIC RESIN EMULSION STAPLES GLUE (USED W/ STAPLES & PIN NAILS) #8 X 2" DRYWALL SCREWS USED TO ATTACH WALL PANELS TO EACH OTHER, TO ATTACH 'L'-SHAPED WALL BRACKET TO TOP OF WALL PANELS AND TO EXISTING WALL DRYWALL SCREWS S G D WALL PANEL FASTENERS USED TO ASSEMBLE PLYWOOD WALL PANEL FRAME & 'L'-SHAPED WALL BRACKET AND TO ATTACH PLYWOOD SHEATHING TO FRAME 1 4" X 2 1 2" TAPCON CONCRETE SCREWS USED TO ATTACH WALL PANELS TO EXISTING CONCRETE FLOOR SLAB TAPCON SCREWST T NEXT TO EACH PANEL JOINT 18GA X 1.25" LONG HEADLESS PIN NAILS USED TO ATTACH PLYWOOD SHEATHING TO FRAME IN FIELD PIN NAILSN A B C S EXTERIOR FINISH FOR ALL WALL PANELS ALL PANEL SHEATHING ALL PANEL FRAMING AND REVEALS - 2" OR 4" WIDE X 3 4" THICK - VERTICAL FRAMING MEMBERS TO BE DOUBLE THICKNESS (1 1 2" TOTAL) AT 16" O.C. OR AS REQUIRED 5 MIN. AT EACH FRAMING JOINT, TYPICAL S APPROX. 6" O.C. ALONG EACH FRAMING MEMBER ASSEMBLED IN SHOP, TYPICAL TO ATTACH SHEATHING TO FRAME G G CONTINUOUS N APPROX. 6" O.C. ALONG TOP AND BOTTOM FRAMING, 30" O.C. ALONG VERTICAL EDGES WHEN SHEATHING IS ATTACHED IN FIELD, TYPICAL G CONTINUOUS D 16" O.C. AT PANEL JOINTS STEEL CONDUIT STRAPS FOR RIGID CONDUIT- ATTACHED TO BLOCKING - SPACED PER NEC - NO MORE THAN 36" APART ALONG LENGTH OF CONDUIT 3 4" RIGID CONDUIT EXTENDS 6" ABOVE TOP PLATE OF WALL PANEL, TYP. ELECTRICAL JUNCTION BOXES ATTACHED TO BLOCKING, TYP. U.L. LABEL - STAPLE TO TOP OF EACH WALL PANEL CONTAINING CONDUIT 9'-11" OR 9'-0" A.F. SEE REFLECTED CEILING PLAN 10'-0" OR 9'-1" A.F. TOP OF WALL PANELS 6" 3" OR 5" SEE PLAN B 1 2" x 2" BLOCKING FOR ATTACHMENT OF ELECTRICAL JUNCTION BOXES, TYP. ELECTRICAL JUNCTION BOXES, STAGGERED - SEE ISOMETRIC VIEW A 3 4" X 4" X 4" X 2'-0" LONG PLYWOOD 'L' BRACKET ATTACHED TO TOP PLATE OF WALL & TO EXISTING WALL WITH D 3 4" RIGID CONDUIT EXTENDS 6" ABOVE TOP PLATE OF WALL PANEL, TYP. EXISTING WALL A PANEL FRAMING- 2" OR 4" WIDE X 3 4" OR 1 1 2" THICK B 1 2" SHEATHING A PANEL FRAMING- 2" OR 4" WIDE X 3 4" THICK T ATTACH PANELS TO FLOOR -EACH PANEL ISOMETRIC VIEW C EXTERIOR FINISH FOR ALL WALL PANELS 3'-11 . 7 5 " P A N E L W I D T H OR A S R E Q ' D - N O T T O E X C E E D 5 ' - 0 " 3 4" X 1 2" REVEAL BETWEEN WALL PANELS - SEE REVEAL DTL ONE SIDE OF SHEATHING INSTALLED IN FIELD AFTER WALL PANELS ARE ATTACHED TO EACH OTHER AND TO FLOOR 1/2" THICK MEDITE FLAME RETARDANT MDF, CLASS 1 (A) FLAME SPREAD: 20 SMOKE DEVELOPED: 100 TESTED IN ACCORDANCE WITH ASTM E-84 3/4" THICK FIRE RETARDANT TREATED PLYWOOD, CLASS 1 (A) FLAME SPREAD: 25 OR LESS SMOKE DEVELOPED: 100 OR LESS TESTED IN ACCORDANCE WITH ASTM E-84 1 INTERIOR PERIMETER PARTITION (NONLOAD-BEARING) NON-RATED FIRE RETARDENT PLYWOOD - CLASS 1A 2 INTERIOR PARTITION (NONLOAD BEARING) NON-RATED FIRE RETARDENT PLYWOOD - CLASS 1APARTITION TYPES 1 1 P1001 UNISTRUT @ 48" O.C. 400S137-33 STUD BRACES @ 48" O.C., ALT. SIDES. SCALE: 2 2.1 TYP. P-LAM. JOINT & REVEAL DETAIL FULL SCALE FILL REVEALS BEHIND BASE MOLDING AND CEILING GRID WITH LAMINATED BLOCKING TO CONCEAL GAP 3/4" PLYWOOD TONGUE AND GROOVE JOINT 1/2" MDF SKINS 3/4"SCREW THROUGH TONGUE AND GROOVE JOINT TO SECURE WALL PANEL CONNECTION - SLIDE LAMINATE STRIP OVER FACE OF REVEAL TO FINISH P. LAM. @ ALL INTERIOR SURFACES OF REVEAL TO MATCH ADJACENT FACE OF P. LAM. SCALE: 3 2.1 TYPICAL DOOR ELEVATIONS N.T.S. TYPE A SEE SCHEDULE SE E S C H E D U L E 7 8" 1/ 8 " 11 1 / 8 " 6"6" 6" SEE SCHEDULE 11 1 / 8 " 6"6" 6" INTERIOR SIDEEXTERIOR SIDE DR2 DL1 3' - 0 " DR1 MANUAL SLIDING DOOR WITH TRACKLESS BOTTOM DH1 DR2 7 1 2" c SCALE: 4 2.1 WINDOW ELEVATION N.T.S. a TEMPERED GLASS b TYPICAL DOOR HARDWARE TYPE KEY DESCRIPTION MODEL NO.MANUFACTURERFINISH HINGES SOFT CLOSE SLIDING BYPASS DOOR SYSTEM W/TRACKLESS BOTTOM DOOR GUIDES 100 SERIES JOHNSON HARDWARE SATIN CHROME LOCKS DH1 DL1 HARDWARE DR1 DR2 4550 MS DEADLOCK LEVER HANDLE 4550 ADAMS RITECLEAR ANODIZED 19" LADDER PULL HANDLE 701DHH2R 1002170 RICHELIEUSTAINLESS STEEL MS SERIES DEADLOCK WITH HOOK BOLT MS1850S-450 -628 ADAMS RITECLEAR ANODIZED 'c' 0'-10" 'b' 7'-8" 'a' 2'-9" WIDTH HEIGHT DISTANCE A.F.WINDOW MATERIAL WINDOW SCHEDULE REMARKS 1/4" TEMP. GLASS1 HARDWARE: ALL DOOR HANDLES SHALL BE LEVER HANDLE TYPE AND FULLY ACCESSIBLE FOR THE HANDICAPPED. WINDOW + DOOR NOTES ALL WINDOW + DOOR HEADS TO ALIGN, TYPICAL, U.O.N. 2. 1. GLAZING TO COMPLY WITH THE FOLLOWING: IBC 2406.3, 2406.3.1 & 2407.1 - SAFETY GLASS SHALL BEAR PERMANENT IDENTIFYING MARKS ON EACH PIECE. IBC 2406.4 & 2407.1 - GLASS SUBJECT TO IMPACT SHALL BE SAFETY GLAZED. WIRED GLASS IS NOT PERMITTED AS SAFETY GLAZING. 3. PEEPHOLE PANEL GLAZED GLAZINGWIDTHDOORHEIGHT DOOR SCHEDULE NO8'-11"YES3'-9" REMARKS 1 3/4" THICKNESS A TYPE DOOR LAMINATED L3 NO. 1 LOCK HINGE DL1 DH11/4" TEMPERED GLASS PROVIDE DR1 AND DR2 FIXED WINDOW PANEL TO VISUALLY MATCH DOOR 1 SEE DOOR DETAIL 3/2.1 SEE WINDOW DETAIL 4/2.1 SEE HEADER DETAIL 5/5.0 3'-4"5'-8"2 NO. 1/2" THICK TEMPERED BUTT-JOINT GLASS W/ PENCIL POLISHED EDGES 4 PANES FACETED ON CURVE SEE CONSTRUCTION NOTE 6 2'-8 1/4" EACH PANE 3 0'-10"8'-2"3'-3"1/2" THICK TEMPERED GLASS SEE CONSTRUCTION NOTE 84 5 0'-10"8'-2"3'-3"1/2" THICK TEMPERED GLASS W/ PENCIL POLISHED TOP EDGE SEE CONSTRUCTION NOTE 76 7 8 ALL GLAZING LESS THAN 1/2" THICK TO HAVE STOPS ON ALL SIDES.4. 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 2.1 WALL PANEL & JOINT DETAILS, WINDOW & DOOR SCHEDULES SCALE: 1 3.0 FRONT ELEVATION 1/2"=1'-0" FINISHED FLOOR 0'-0" B1 VIDEO DISPLAY 9'-11" A.F.F. A.C.T.CLG. L2 B1 B1L1 L2 L3 ATM P1 L1 L3L3 P1 L2 L3 B1L1B1 P1 P1 P1 L1 L2L1L1L1L1L1L1 B1 L3 L3 L3B1L3 L1 L1 L1 L1 L3L3 SS SS SSSS 5" 11 " 8' - 2 " G L A S S , T Y P . 10 " 5' - 1 " SCALE: 2 3.0 BUILDING SECTION 1/2" = 1'-0" FINISHED FLOOR 0'-0" A.C.T. CLG. 9'-11" A.F.F. L2 9'-6" A.F.F. B/DECORATIVE BEAM B1 L1 B1 CEILING SUSPENDED FROM STRUCTURE ABOVE L1L1 L1 SS L3 L2 L1 L1 SCALE: 3 3.0 END ELEVATION 1/2"=1'-0" FINISHED FLOOR 0'-0" 9'-11" A.F.F. A.C.T.CLG. L2 L1 B1 5" SCALE: 4 3.0 ELEVATION - TELLER RIGHT 1/2" = 1'-0" 9'-11" A.F.F. KEY AS SCHEDULEDB1 SS L2 L1 14 4.0 2 4.1 1'-8"1 1 2"1'-4" L2 3' - 0 " SIM. INSTANT ISSUE INSIDE SCALE: 5 3.0 ELEVATION - REAR WALL 1/2" = 1'-0" 9'-11" A.F.F. B1 P1 VIDEO DISPLAY SAMSUNG QB85C OFOI WB1 MM1 5' - 9 " T O C E N T E R O F IN - W A L L B O X & M O U N T 13'-6" FROM RIGHT SIDE WALL TO CENTER OF IN-WALL BOX & MOUNT SCALE: 6 3.0 ELEVATION - TELLER LEFT 1/2" = 1'-0" 9'-11" A.F.F. KEY AS SCHEDULEDB1 SS L3 L1 14 4.0 1 4.1 1'-8"4"1'-10" 3' - 0 " L1 P1 3' - 4 " CHECK PRINTER INSIDE SCALE: 7 3.0 ELEVATION - TELLER REAR 1/2" = 1'-0" 9'-11" A.F.F. KEY AS SCHEDULED SS 10 4.0 1'-8" L1 3' - 0 " LOCKING DRAWER W/ CASH TRAY INSERT, TYP. LOCKING STORAGE DRAWER, TYP. LOCKING CABINET W/ TRASH SLOT IN DOOR, TYP. PROVIDE DOOR- MOUNT TRASH CAN INSIDE EACH CABINET DOOR. WIRE CHASE, TYP. SIDE OF CABINET FACING TCR TO BE OPEN FOR VENTILATION AND ACCESS TO REAR OF TCR, TYP. (CASH) 9" L1 KNEE WALL SS L1 TCR 3' - 4 1 / 2 " SS 2'-4"1 1 2" L1 L1 L3 10 " 1'-8" (CASH) 1'-8" 1'-10"6"1'-10"3'-0" SS L3 L1 L1 CL2 YALE LOCK AT TELLER CPU/COIN CABINET, TYP. L1 L1 1'-8" (CASH) TCR 3' - 4 1 / 2 " 1'-8" (CASH) 1'-8"2'-4" 3' - 0 " 1 1 2"3'-0" L1 KNEE WALL 10 " 1'-10"6"1'-10"3'-0" SSL3 SS L1 L1 SSL3 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 3.0 BRANCH SECTION & ELEVATIONS, MILLWORK SECTIONS SCALE: 1 3.1 ELEVATION - OFFICE DESK 1/2" = 1'-0" 9'-11" A.F.F. 2' - 6 1 / 2 " B13'-6" SINGLE SPACE 3" DIA. SUPPORT LEG - BRUSHED ALUMINUM MODESTY PANEL L1 3'-5" 1'-11" SS L1 8 4.0 L3 2'-0" KEY AS SCHEDULED L1 L3 3' - 4 " 2'-8 1/8" WIRE CHASEL1 L3 SCALE: 2 3.1 ELEVATION - OFFICE CREDENZA 1/2" = 1'-0" 9'-11" A.F.F. P1 SS 1 1 2"1'-9" KEY AS SCHEDULED 2' - 6 1 / 2 " 3' - 4 " 13B 4.0 L1 2 4.0 1'-9" B1 L3 L1 WIRE CHASE L3 L1 13A 4.0 P1 2'-9" SINGLE SPACE 2'-8" SINGLE SPACE 2 4.0 ALARM PANEL INSIDE ALARM PANEL INSIDE ALARM POWER SUPPLY INSIDE 1'-5" SCALE: 3 3.1 ELEVATION - OFFICE EQUIP. CABINET 1/2" = 1'-0" 9'-11" A.F.F. KEY AS SCHEDULED SS 11 4.0 3 4.0 2'-9 3/4" SINGLE SPACE 1 1 2" EQUIP RACK INSIDE 2'-8 1/2" SINGLE SPACE L1 1 4.0 SAFE INSIDE 1 1 2"1 1 2"2'-8 1 8"13 4" 1 1 2" 2' - 6 1 / 2 " L1 L1 2' - 8 1 / 2 " 1 1 2"2'-95 8" 3 4.1 FLUSH ACCESS DOOR - ELEC. PANEL INSIDE 4' - 8 " L2 L2 L2 B1 OPENING TO WIRE CHASE INSIDE INSTALL (6) ADHESIVE HEADSET MOUNTS HH1 1' - 0 " 8"8"5" 1' - 0 " 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 3.1 MILLWORK ELEVATIONS 4" 11 2" 7" 1' - 1 " 2' - 6 1 2" SCALE: 13B 4.0 SECTION - CREDENZA 1" = 1'-0" 13A 4.0 HANGING BRACKETS TO RECEIVE ALUMINUM FILE HANGING BAR - SPACE AS REQUIRED FOR LEGAL AND LETTER SIZE FILES. TYP. ALL FILE DRAWERS NOTE: 13B/4.0 - CABINET OPEN INSIDE W/ (1) SHELF ON SHELF PINS LINE BORE CABINET SIDES @ 1" O.C. - ONLY UPPER DRAWER @ 13B/4.0 DRAWER @ 13A ONLY DRAWER @ 13A ONLY WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - NO HOLES ON END PANELS 5" 2'-0" LAMINATE TOE KICK SAME AS FACE 3" x 1/2" BACKSPLASH WHERE COUNTER MEETS WALLS - FINISH SAME AS COUNTER 1- 1 / 2 " 1 2" LEGAL C CL BRACKET L BRACKET 1'-01 4" 1'-31 4" ONLY WHERE INDICATED ON PLAN TOP DRAWER TO ACCOMMODATE CASH TRAY INSERT 14-3/4"W x 14-13/16"D x 3-1/4"H PROVIDE 1/2"x1/8" THICK ALUM. BARS TO SUPPORT HANGING FILE FOLDERS - SET UP + FIT IN SHOP TO ENSURE ACCURATE AND FUNCTIONAL FIT (DASHED) MILLWORK NOTES PROVIDE CAM LOCKS AT CABINETS AND DRAWERS AS INDICATED ON ELEVATIONS. KEY AS SCHEDULED. 1. 2. ALL MILLWORK EXCEPT CABINET DOORS TO BE OF CABINET GRADE BIRCH PLYWOOD. ALL MILLWORK INTERIORS TO BE OF PREFINISHED CABINET GRADE PLYWOOD WITH A DURABLE CLEAR FINISH. ALL CABINET DOORS TO BE MDF. LAMINATE INSIDE OF DOORS SAME AS FACE. EDGE BAND DOORS AND SHELVES IN EDGE BANDING TAPE OR LAMINATE TO MATCH FACE. 3. PROVIDE BLOCKING IN WALL PANELS TO SUPPORT INSTALLATION OF WALL MOUNTED MILLWORK OR EQUIPMENT (CABINETS, SHELVES, MONITORS, BROCHURE RACKS, CHECKWRITERS, ETC.) AS SHOWN ON PLAN. 4. LAMINATE GRAIN: VERTICAL AT ALL WALLS, CABINET FACES, CABINET DOORS, DOORS, GATES, KNEEWALLS, TELLER PARAPETS, TELLER LINE TRIM, LOW WALLS, COLUMNS AND OTHER GENERALLY VERTICAL OBJECTS U.N.O.; HORIZONTAL AT ALL HORIZONTAL BEAMS, HORIZONTAL CHASES, SIGN PLAQUES AND OTHER GENERALLY HORIZONTAL OBJECTS U.N.O. 5. 4" 11 2" 3" 2' - 6 1 2" SCALE: 8 4.0 SECTION - CPU CABINET 1" = 1'-0" 1' - 1 0 " 10" LAMINATE TOE KICK SAME AS FACE 3" x 1/2" BACKSPLASH WHERE COUNTER MEETS WALLS - FINISH SAME AS COUNTER VENTILATION SLOT, CONTINUOUS WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - HOLES ON END PANELS VENTILATION SLOT, CONTINUOUS 4" 1 1 2" 7" 1' - 5 " 3' - 0 " SCALE: 14 4.0 SECTION - BASE CABINET 1" = 1'-0" WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS 6 1 2" 2'-0" LAMINATE TOE KICK SAME AS FACE 3" x 1/2" BACKSPLASH WHERE COUNTER MEETS WALLS - FINISH SAME AS COUNTER HARDWARE SCHEDULE HARDWARE KEY DESCRIPTION MODEL NO.MANUFACTURER CARPET METAL TRIM 1-1/4" SEAM BINDER FLOORING TRANSITION STRIP 3" FLIP TOP ROUND GROMMET SET GROMMETS CM 703 HMF FUTURA XG3-23 DOUG MOCKETT FINISH HAMMERED MILL FINISH METALLIC SILVER FLEXIBLE DOOR STOP 4" PROJECTION DOOR STOPS 061 F26D IVESSATIN CHROME CABINET/DRAWER LOCKS CAM LOCKS LP-700 COMPX TIMBERLINE SATIN NICKEL CABINET/DRAWER PULLS DRAWER GUIDES HEAVY DUTY SLIDES FOR FILE DRAWERS 4034 ACCURIDECLEAR ZINC MEDIUM DUTY SLIDES FOR BOX DRAWERS 3832 ACCURIDECLEAR ZINC CABINET HINGES "CLIP TOP" CONCEALED HINGES 73T5580-180 BLUMNICKEL HEAVY DUTY FULL EXTENSION SLIDES FOR PULL-OUT SHELF ACCURIDECLEAR ZINC 1-GANG BLANK WALLPLATESWITCH/OUTLET COVER PLATES LEV 84014-40 1G SS LEVITONBRUSHED STAINLESS 1-GANG DUPLEX RECEPTACLE WALLPLATE LEV 84003-40 S8-N 1G SS LEVITONBRUSHED STAINLESS MONITOR MOUNTS 1-GANG DECORA SWITCH WALLPLATE LEV 84401-40 S1-N 1G SS LEVITONBRUSHED STAINLESS 2-GANG DUPLEX RECEPTACLE WALLPLATE LEV 84016-40 S82N 2G SS LEVITONBRUSHED STAINLESS 2-GANG DECORA SWITCH WALLPLATE LEV 84409-40 2G SS LEVITONBRUSHED STAINLESS 3-GANG DECORA SWITCH WALLPLATE LEV 84411-40 3G SS LEVITONBRUSHED STAINLESS GR1 FT1 CP1 CP2 CP3 CP4 CP5 CP6 DS1 CL1 DP1 DG1 DG2 DG3 MM1 HI1 IN-WALL BOX WB1 CHIEF MANUFACTURING 4.5" CONTEMPORARY METAL HANDLE BOW PULL 3511 FINISH 195 RICHELIEUBRUSHED NICKEL FT2 SLIM LINE TRANSITION FOR STRAIGHT APPLICATIONS SLT-38-B JOHNSONITE"PEWTER" #38 BLACK RMF3MEDIUM FIT FIXED DISPLAY WALL MOUNT SERIES 3 FOR 32"-65" DISPLAYS WHITEPROXIMITY IN-WALL STORAGE BOX WITH FLANGE & COVER, SMALL (9"H x 14.25"W x 3.9"D) PAC525FCW CHIEF MANUFACTURING YALE STYLE MECHANICAL CABINET LOCKS DY311KA ULTIMATESECURITY DEVICES.COM CL2 3/4" x 10'-0" STAINLESS STEEL CORNER GUARDS CORNER GUARDS STAINLESS STEELCG1 HEADSET HANGER HH1 TOTALMOUNTBLACKSTUDIO HEADPHONE HOLDER - TWO PACK (PROVIDE TOTAL OF 6 PIECES) AMAZON ASIN B09GXMV284 KEY SCHEDULE KEY NO.LOCATION 100 101 102 TELLER AREA - ALL LOCKS EXCEPT TELLER STATION CPU/COIN CABINETS CL1 1 TELLER STATION #1 CPU/COIN CABINET CL2 2 TELLER STATION #2 CPU/COIN CABINET CL2 3 OFFICE - ALL LOCKS AS SHOWN ON ELEVATIONS EXCEPT SHRED BIN CL1 4 SHRED BIN CL1 TELLER STATION #3 CPU/COIN CABINET CL2 TELLER STATION #4 CPU/COIN CABINET CL2 SCALE: 2 4.0 SECTION - FULL HT CABINET 1" = 1'-0" 4" 2' - 8 " 2' - 7 " 2' - 2 " 1'-4" 9'-11" A.F.F. 2" 2' - 0 " LINE BORE CABINET SIDES AT 1" O.C. - PROVIDE ADJ. 5mm SHELF PINS FOR SHELF SUPPORT LINE BORE CABINET SIDES AT 1" O.C. - PROVIDE ADJ. 5mm SHELF PINS FOR SHELF SUPPORT LAMINATE TOE KICK SAME AS FACE LINE BORE CABINET SIDES AT 1" O.C. - PROVIDE ADJ. 5mm SHELF PINS FOR SHELF SUPPORT WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - NO HOLES ON END PANELS SCALE: 1 4.0 SECTION - EQUIPMENT CABINET 1" = 1'-0" 1" 2'-10" 2' - 9 " 9'-11" A.F.F. 4' - 2 " FULL DEPTH PULL-OUT SHELF ON HEAVY DUTY GLIDES TOP OF CABINET OPEN WITH WIRE MESH COVER FOR VENTILATION VAULT EQUIP RACK 2" PROVIDE FOUR 3" AIRFLOW OPENINGS - PAINT EDGES BLACK 2' - 1 0 " PROVIDE FOUR 3" AIRFLOW OPENINGS - PAINT EDGES BLACK SCALE: 3 4.0 SECTION - FULL HT CABINET 1" = 1'-0" 4" 2' - 0 " 2' - 7 " 2' - 2 " 1'-4" 9'-11" A.F.F. 2" 2' - 0 " LINE BORE CABINET SIDES AT 1" O.C. - PROVIDE ADJ. 5mm SHELF PINS FOR SHELF SUPPORT LAMINATE TOE KICK SAME AS FACE 4" 2" 2" FULL WIDTH SLOT WITH FULL WIDTH STAINLESS STEEL DEFLECTOR AFFIXED INSIDE BELOW SLOT 2"2" 1' - 1 0 1 2" PROVIDE 4 HOOKS (ONE AT EACH UPPER CORNER) TO HOLD COLLECTION BAG (BAG PROVIDED BY FINANCIAL INSTITUTION) 1"x2" LEDGER TO SUPPORT BAG HOOKS 1' - 0 " 1' - 0 " INSTALL (6) ADHESIVE HEADSET MOUNTS HH1 WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - NO HOLES ON END PANELS SCALE: 10 4.0 SECTION - TELLER CABINET 1" = 1'-0" TOP DRAWER TO ACCOMMODATE CASH TRAY INSERT 14-3/4"W x 14-13/16"D x 3-1/4"H 1 1 2" 7" 3' - 0 " 4" LAMINATE TOE KICK SAME AS FACE1'-11" WIRE CHASE SS 1 1 2" 2' - 0 1 2" 10 " 4 1 2" 1 2"4"5" L1 L3 7" L1 1' - 5 " 6 1 2" TRASH CAN TRASH SLOT 1"2" 10 " 2'-11" REAR OF CABINET OPEN FOR WIRING ACCESS - THIS NEEDS TO ALLOW ACCESS TO OUTLETS INSTALLED IN KNEEWALL/WIRE CHASE CPU & STACKED COIN TRAYS 4" 1 1 2" 1' - 0 1 2" 1' - 0 1 2" 2' - 6 1 2" SCALE: 11 4.0 SECTION - LATERAL FILE 1" = 1'-0" HANGING BRACKETS TO RECEIVE ALUMINUM FILE HANGING BAR - SPACE AS REQUIRED FOR LEGAL AND LETTER SIZE FILES. TYP. ALL FILE DRAWERS WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - NO HOLES ON END PANELS 2'-0" LAMINATE TOE KICK SAME AS FACE 3" x 1/2" BACKSPLASH WHERE COUNTER MEETS WALLS - FINISH SAME AS COUNTER LEGAL C CL BRACKET L BRACKET 1'-0 1 4" 1'-3 1 4" 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 4.0 MILLWORK SECTIONS & DETAILS, KEY & HARDWARE SCHEDULE 4" 2'-1" 3' - 0 " 1' - 9 1 / 2 " SCALE: 2 4.1 SECTION - INSTANT ISSUE 1" = 1'-0" 1 1 / 2 " WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - NO HOLES ON END PANELS LAMINATE TOE KICK SAME AS FACE 3" x 1/2" BACKSPLASH WHERE COUNTER MEETS WALLS - SAME FINISH AS COUNTER TOP INSTANT ISSUE MACHINE FULL DEPTH PULL-OUT SHELF ON HEAVY DUTY FULL EXTENSION GLIDES DG3 1 1/2" 9" 1/2" 1'-9 1/2" 1' - 6 1 / 4 " CL E A R 4" 2'-0" 3' - 0 " 1' - 5 1 / 2 " SCALE: 1 4.1 SECTION - PRINTER WELL 1" = 1'-0" 1 1 / 2 " WIRE ACCESS HOLES TO ALIGN WITHIN BANK OF CABINETS - NO HOLES ON END PANELS LAMINATE TOE KICK SAME AS FACE 3" x 1/2" BACKSPLASH WHERE COUNTER MEETS WALLS - SAME FINISH AS COUNTER TOP PRINTER 1'-4" CUT-OUT IN COUNTERTOP FOR PRINTER ACCESS - FINISH INSIDE EDGES FULL DEPTH PULL-OUT SHELF ON HEAVY DUTY GLIDES 2" 1' - 1 " HANGING BRACKETS TO RECEIVE ALUMINUM FILE HANGING BAR - SPACE AS REQUIRED FOR LEGAL AND LETTER SIZE FILES. TYP. ALL FILE DRAWERS 1' - 2 1 / 4 " CL E A R SCALE: 3 4.1 SECTION - UPPER CABINET 1" = 1'-0" 9'-11" A.F.F. 1'-4" 4" 4' - 2 " 2' - 6 " FULL OVERLAY DOOR LINE BORE CABINET SIDES AT 1" O.C. - PROVIDE ADJ. 5mm SHELF PINS FOR SHELF SUPPORT FINISH WITH WHITE CABINET LINER UNDERCABINET LIGHT FIXTURE PROVIDE REMOVABLE COVER FOR LIGHT FIXTURE POWER SUPPLY CONTINUOUS UNDER CABINET AT WALL POWER LOCATION WITH WIRE OPENING FACING LIGHT FIXTURE - MOUNT CONNECTING WIRE TIGHT TO INSIDE CORNERS TO KEEP OUT OF VIEW 2" 2' - 0 " SEISMIC CEILING APPLICATIONS GUIDE - IBC CATEGORY "D, E & F" BASIC CONNECTIONS, PERIMETER, AND LATERAL SPLAY BRACING REQUIREMENTS MINIMUM INTERSECTION STRENGTH LIMITS @ MT / CT 180 LBS VERTICAL HANGER WIRE 12-GAUGE @ 4' O.C. REQUIRED CONNECTION DEVICE FROM VERTICAL WIRE TO THE STRUCTURE ABOVE MUST SUSTAIN MIN 100 LBS REQUIRED MAIN TEE CLASSIFICATIONS HEAVY-DUTY 1 IN 6 MAX PLUMB OF VERTICAL HANGER WIRES REQUIRED PERIMETER VERTICAL HANGER WIRES NOT MORE THAN 8" FROM WALL REQUIRED GRID END/WALL CLEARANCE MIN 3/4" PERIMETER CLOSURE (MOLDING) WIDTH MIN 2 " GRID CONNECTION TO PERIMETER ATTACHED ON TWO ADJACENT WALLS REQUIRED PERIMETER TEE ENDS TIED TOGETHER REQUIRED HORIZONTAL RESTRAINT (SPLAY WIRES OR RIGID BRACING) WITHIN 2" OF INTERSECTION AND SPLAYED 90° APART AT 45° ANGLES REQUIRED COMPRESSION POSTS (STRUTS) 12' O.C. IN BOTH DIRECTIONS, STARTING 6' FROM WALLS REQUIRED SPLAY BRACING CONNECTION STRENGTH 200 LBS OR THE DESIGN LOAD, WHICHEVER IS GREATER REQUIRED PARTITION ATTACHMENT BRACING INDEPENDENT OF CEILING SPLAY BRACING SEISMIC SEPARATION JOINT4 REQUIRED FOR AREAS > 2,500 SQ. FT. (OR FULL HEIGHT PARTITION) RIGID BRACING FOR CEILING PLANE ELEVATION CHANGES REQUIRED LIGHT FIXTURE ATTACHMENT REQUIREMENTS LIGHT FIXTURE (ALL TYPES) MECHANICALLY ATTACHED TO GRID NEC 410-16 (TWO PER FIXTURE UNLESS INDEPENDENTLY SUPPORTED)REQUIRED SURFACE-MOUNTED FIXTURES ATTACHED TO GRID NOT REQUIRED PENDANT-HUNG FIXTURES DIRECTLY SUPPORTED FROM STRUCTURE WITH 9-GAUGE WIRE (OR APPROVED ALTERNATIVE)REQUIRED RIGID LAY-IN OR CAN LIGHT FIXTURES ≤ 10 LBS – ONE WIRE TO STRUCTURE (MAY BE SLACK)REQUIRED 11 TO 56 LBS – TWO WIRES FROM HOUSING TO STRUCTURE (MAY BE SLACK)REQUIRED ≥ 57 LBS – SUPPORTED DIRECTLY TO STRUCTURE BY APPROVED REQUIRED LIGHT FIXTURE SUPPLEMENTARY HANGER WIR REQUIREMENTS INTERMEDIATE DUTY MAIN TEES WITH CROSS TEE RATING BELOW 16 LBS./LF REQUIRED MIN. 12-GAUGE HANGER WIRES MUST BE ATTACHED TO THE GRID MEMBERS WITHIN 3 INCHES OF EACH CORNER OF EACH LIGHT FIXTURE. HEAVY DUTY MAIN TEES WITH CROSS TEE RATING BELOW 16 LBS./LF REQUIRED MIN. 12-GAUGE HANGER WIRES MUST BE ATTACHED TO THE SUPPORTING CROSS TEE WITHIN 3 INCHES OF THE CORNER OF EACH LIGHT FIXTURE. SUPPLEMENTARY HANGER WIRES FOR HEAVY DUTY MAIN TEES WITH CROSS TEE RATING EQUAL TO 16 LBS./LF NOT REQUIRED SERVICE APPLICATIONS REQUIREMENTS AIR TERMINALS 20 LBS – POSITIVELY ATTACHED TO GRID REQUIRED 21 TO 56 LBS – POSITIVELY ATTACHED TO GRID AND TWO WIRES TO STRUCTURE (MAY BE SLACK) REQUIRED ≥ 57 LBS – DIRECTLY SUPPORTED TO STRUCTURE REQUIRED SPRINKLER HEADS AND OTHER PENETRATION CLEARANCE MIN 2" DIA. OPENING OR A SWING JOINT CABLE TRAYS AND ELECTRICAL CONDUIT INDEPENDENTLY SUPPORTED AND BRACED REQUIRED NOTES 1. REFERS TO CISCA INSTALLATION RECOMMENDATIONS FOR ZONES 3-4 VIA ASCE 7. 2. THE ABOVE INFORMATION IS CORRECT TO THE BEST OF OUR KNOWLEDGE AT THE DATE OF ISSUANCE. BECAUSE CODES CONTINUE TO EVOLVE, CHECK WITH A LOCAL OFFICIAL PRIOR TO DESIGNING AND INSTALLING A CEILING SYSTEM. THIS IS ONLY INTENDED AS A QUICK REFERENCE. 3. REQUIRED FOR CEILINGS LARGER THAN 1,000 SQUARE FEET. 4. WHERE SUBSTANTIATING DESIGN CALCULATIONS ARE NOT PROVIDED. USG SEISMIC CEILING RESOURSE CENTER 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 4.1 MILLWORK SECTIONS & DETAILS SCALE: 1 5.0 REFLECTED CEILING/ LIGHTING PLAN 1/2" = 1'-0" 15/16" SCALE: 2 5.0 SUSP. CLG SYS. DETAIL FULL SCALE 3/4" X 3/4" ANGLE FIELD CUT SCALE: 3 5.0 SUSPENDED CLG SYS.DTL N.T.S. HANGER WIRE (12 GAUGE GALVANIZED STEEL WIRE) WRAP 3 FULL TIMES CROSS "T" MAIN RUNNER ACOUSTICAL LAY-IN PANEL WALL ANGLE LIGHT COVE UNSWITCHED NIGHT LIGHT ALWAYS ON FOR SECURITY x C 9'-6" A.F.F. BOTTOM OF DECORATIVE BEAM 9'-11" A.F.F. A.C.T. CLG. 9'-11" A.F.F. A.C.T. CLG. 4 5.0 A1 C A1 A1 A1 A1A1 A2 D (IN COVE) D (IN COVE) D ( I N C O V E ) B ( S U S P E N D E D ) B ( S U S P E N D E D ) B ( S U S P E N D E D ) B ( S U S P E N D E D ) E- 3 0 " (U N D E R C A B . ) x 5 5.0 2'-5"3' - 6 " 8'-6"8'-6"5'-0"3' - 6 " 2'-0" 2' - 1 0 " 4' - 7 " 1' - 0 " 6" 4' - 1 " 4' - 1 " 4' - 1 " 4' - 1 " CE N T E R O F C A N O P Y . T Y P . 5'-4" TO CENTER OF CANOPY, TYP. 7'-10"5'-4"4'-3" 4' - 0 " 3' - 6 " 3' - 6 " 8'-4" A.F.F. EXISTING BULKHEAD 9'-11" A.F.F. EXISTING A.C.T. CLG. EXISTING GRID, SPRINKLERS, AND STORE LIGHT FIXTURES TO REMAIN, TYP. (DASHED) 9'-0" A.F.F. BOTTOM OF HEADER 9'-0" A.F.F. BOTTOM OF HDR REPLACE EXISTING CEILING TILES TO MATCH EXISTING AS NEEDED ALONG LEASE LINE TO REPAIR ANY DAMAGE INCURRED DURING DEMOLITION OR CONSTRUCTION 7'-8" A.F.F. BOTTOM OF FIXTURE, TYP. OF 4 LIGHT COVE z1 z1 z1 z2 z2 z2 z2 z2 z2 y y y y y 9'-0" A.F.F. BOTTOM OF DECORATIVE BEAM, TYP OF 6 6 5.0 D (IN COVE) SYMBOLS LEGEND 2'x2' WHITE ACOUSTICAL CEILING TILE AND SUSPENSION SYSTEM - SEE FINISH SCHEDULE C1 ITEM KEY MANUFACTURER & NUMBER INPUT WATTSDESCRIPTION QTY THERMOSTAT - MOUNT AT 48" A.F.F. TO BE INSTALLED TO EXTEND THROUGH NEW A.C.T. CEILING PER PLAN AND PER CODE - BY SPRINKLER CONTRACTOR 1 LAY-IN PLAQUE-FACED HVAC SUPPLY DIFFUSER. CONNECT TO TRUNK LINE ABOVE PER CODE. SEE MECHANICAL. LAY IN PLAQUE-FACED HVAC RETURN GRILLE. CONNECT TO TRUNK LINE ABOVE PER CODE. SEE MECHANICAL. SEE FINISH SCHEDULE C1 24x24 TITUS OMNI OR EQUAL 24x24 TITUS OMNI OR EQUAL WHITE, FLUSH MOUNT, CONCEALED SPRINKLER HEADS 6 1 JESCO FLEX2 MODULAR LINEAR LED STRIP LIGHTING SYSTEM - STD OUTPUT - LOW PROFILE, FLEXIBLE, 120° BEAM ANGLE, 24V DC, 18 LEDS/FT, 30FT MAX RUN, 3800-4150K COLOR TEMP, 128.6 L/FT, 90+ CRI, ADHESIVE TAPE MOUNT 1.33W/ FT JESCO DL-FLEX2-UP- 4090 PORTFOLIO 6-INCH ROUND LED RECESSED WIDE BEAM DOWNLIGHT, 1000 LUMENS, 0-10V DIMMING, 120V-277V, 90CRI, 4000K, SPUN ALUMINUM MEDIUM BEAM REFLECTOR, WHITE PAINTED SELF FLANGED, SPECULAR CLEAR PORTFOLIO LD6C 10 9040 D010 B26 W2LI 10.04W 23FT A1 A2 16.17W LITHONIA 2'X2' LED RECESSED DIRECT/INDIRECT LIGHT FIXTURE - 0-10V (DIMS TO 1%) DIMMING DRIVER, 2073 LUMENS, 80CRI, 4000K COLOR TEMP. 15.9WLITHONIA 2VTL2-20L-ADP-EZ1- LP840 2 C B (SUSPENDED) E-30" (UNDER CAB.) aspectLED 30" LED UNDER CABINET LIGHT BAR - 30" LONG x 3 8"H x 3 4"W, 580 LUMENS, NEUTRAL/ COOL WHITE, MOUNTING CLIPS INCLUDED aspectLED AL-LB-LP-30IN 24VDC NW - PROVIDE NON-DIMMING POWER SUPPLY 7.3W PORTFOLIO 6" ROUND NEW CONSTR. DOWNLIGHT WALL WASH, 1500 LUMENS, 90 CRI, 4000K, WITH HANGING BARS, SINGLE WALL WASH SPUN ALUM., WHITE PAINTED SELF-FLANGED, SPECULAR CLEAR REFLECTOR PORTFOLIO LD6C- 15-9040-D010-B26- SWN-2LI 4PLT SOLUTIONS 4FT LINEAR SUSPENDED 30%UP/70%DOWN DIRECT/INDIRECT LED FIXTURE, 1860 LUMENS UP/ 4340L DOWN, 0-10V DIMMING, 120V-277V, 80CRI, SET TO 4000K, SILVER W/ FROSTED PC LENS, 124 EFFICACY PLT SOLUTIONS PLT-90272 (SET TO 4000K, MIDDLE COLOR SETTING) 50W ITEM KEY MANUFACTURER & NUMBER DESCRIPTION SCALE: 4 5.0 SECTION - SLIDING DOOR HEADER 1" = 1'-0" LAMINATE BOTTOM OF COVE WHITE A.C.T. CLG. 9'-11" A.F.F. 9'-0" A.F.F. BOTTOM OF SLIDING DOOR HEADER 11 " L1 L1 2 1 2"5 1 2"INTERIOR EXTERIOR PLYWOOD BOX BEAM - LAMINATED 1/2" PLYWOOD SKINS ON 3/4" PLYWOOD RIBS AT 16" O.C. OR AS REQUIRED 3 5/8" 20 GA. METAL STUDS DIAGONAL BRACING TO STRUCTURE ABOVE @ 4'-0" O.C., ALTERNATE DIRECTION CONTINUOUS FIRE RETARDANT PLYWOOD BLOCKING. SUPPORT W/ 1/2" DIA. THREADED ROD @ 4'-0"O.C. MAX., ATTACH TO EXISTING STRUCTURE ABOVE. COUNTERSINK ROD IN BLOCKING. FLEXIBLE LED COVE LIGHTING, CONTINUOUS. POSITION IN COVE FACING UP 5"3" 6" P1 SCALE: 5 5.0 SECTION - OFFICE WALL HEADER 1" = 1'-0" LAMINATE BOTTOM OF COVE WHITE A.C.T. CLG. 9'-11" A.F.F. 9'-0" A.F.F. BOTTOM OF HEADER 11 " L1 L1 8 1 2"INTERIOR EXTERIOR PLYWOOD BOX BEAM - LAMINATED 1/2" PLYWOOD SKINS ON 3/4" PLYWOOD RIBS AT 16" O.C. OR AS REQUIRED 3 5/8" 20 GA. METAL STUDS DIAGONAL BRACING TO STRUCTURE ABOVE @ 4'-0" O.C., ALTERNATE DIRECTION FLEXIBLE LED COVE LIGHTING, CONTINUOUS. POSITION IN COVE FACING UP 5"3" 6" P1 1/2" BUTT-JOINT GLAZING SCALE: 6 5.0 SECTION - iTM ALCOVE 1" = 1'-0" FLEXIBLE LED COVE LIGHTING, CONTINUOUS, POSITION IN OUTSIDE UPPER CORNER FACING DOWN 6" L1 P1HEADER HEADER L2 INSIDE ALCOVE ATM ALCOVE 45 8" 5'-6" A.F.F. A.C.T. CEILING 5'-1" A.F.F. BOTTOM OF HEADER 9'-0" A.F.F. BOTTOM OF HEADER LAMINATE BOTTOM OF COVE WHITE 11 " PLYWOOD BOX BEAM - LAMINATED 1/2" PLYWOOD SKINS ON 3/4" PLYWOOD RIBS AT 16" O.C. OR AS REQUIRED FLEXIBLE LED COVE LIGHTING, CONTINUOUS. POSITION IN COVE FACING UP 5"3" 6" P1 9'-11" A.F.F. EXISTING A.C.T. CEILING LAMINATE INSIDE OF COVE WHITE 9'-6" A.F.F. TOP OF COVE L2SIDE WALLS 8" 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS 10.07.2024 SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : STATE OF WASHINGTON JEFFERY S. CROCKER REGISTERED ARCHITECT 10718 5.0 REFLECTED CEILING PLAN 1.MOUNT THERMOSTATS 48" ABOVE FINISH FLOOR. 2.DUCTWORK AND EQUIPMENT SHOWN IS DIAGRAMMATIC. COORDINATE AND ROUTE DUCTWORK TO MEET JOB REQUIREMENTS. LOCATION OF EQUIPMENT MUST BE COORDINATED WITH ALL DISCIPLINES BEFORE FINAL LOCATIONS ARE SELECTED. WEIGHTS OF EQUIPMENT MUST BE VERIFIED AND COORDINATED WITH STRUCTURAL SYSTEMS BEFORE EQUIPMENT CAN BE INSTALLED AT JOBSITE. 3.SPACE ALLOCATED FOR MECHANICAL AND OTHER WORK ABOVE THE SUSPENDED CEILINGS IS CRITICAL. LIGHT FIXTURES AND AIR DIFFUSERS HAVE BEEN LOCATED TO ACHIEVE A DEFINITE ARCHITECTURAL EFFECT AND MAY NOT BE CHANGED WITHOUT THE CONSENT OF THE ARCHITECT. BECOME FAMILIAR WITH THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS PRIOR TO FABRICATING AND INSTALLING ANY MATERIALS. HANG DUCTWORK AS CLOSE AS POSSIBLE TO THE STRUCTURE ABOVE, UNLESSINDICATED OTHERWISE. 4.LOCATE CEILING DIFFUSERS, REGISTERS AND GRILLES AS SHOWN ON THE ARCHITECTURAL REFLECTED CEILING PLANS. 5.FLEXIBLE RUNOUTS TO BE SAME SIZE AS DIFFUSER NECK. REFER TO DIFFUSER SCHEDULE AND A MAX. OF 8'- 0" IN LENGTH . MECHANICAL SPECIFICATIONSMECHANICAL CONTRACTOR NOTES DUCTWORK: 1.GALVANIZED STEEL IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS. 2.ELBOWS; SQUARE TYPE WITH TURNING VANES. 3.BRANCH TAKE-OFF FROM MAIN DUCTS; SPLITTER DAMPERS OR EXTERNALLY ADJUSTABLE EXTRACTORS. 4.FLEXIBLE DUCTWORK; INSULATED WITH 1" THICK FIBERGLASS WITH A VAPOR BARRIER; FLAME SPREAD RATING NOT OVER 25 AND DEVELOPED SMOKE RATING NOT OVER 50. CONNECT WITH CIRCUMFERENTIAL COMPRESSION CLAMPS OF STAINLESS STEEL OR NYLON. 5.SPIN-IN FITTINGS; MANUFACTURED ROUND GALVANIZED COLLAR DESIGNED TO SCREW INTO A MATING HOLE, WITH AN AIR EXTRACTOR AND MANUAL BALANCING DAMPER. THERMAFLEX, WIREMOLD, CLEVAFLEX. 6.ALL DUCTWORK CONNECTION SHALL BE SEAL. THIS INCLUDE BUT NOT LIMITED TO WATER PROOF AND VAPOR PROOF SEAL. GC SHALL GUARANTEE DUCTWORK INSTALLATION WONT GENERATE CONDENSATION TO THE SPACE. INSULATION: 1.INSULATION, INCLUDING FACING, JACKETS, AND ADHESIVE USED TO ADHERE THE FACING OR JACKET; NOT EXCEEDING A FLAME SPREAD OF 25, NOR A SMOKE DEVELOPED RATING OF 50AS, TESTED IN ACCORDANCE WITH ASTM E84 AND UL LISTED. 2.SUPPLY DUCTWORK; 2" THICK BLANKET TYPE FIBERGLASS INSULATION WITH A MINIMUM DENSITY OF 1 LB/CU. FT., AND FACTORY APPLIED FLAME RETARDANT FOIL-REINFORCED KRAFT FACING. WRAP INSULATION ON THE DUCTWORK WITH ALL CIRCUMFERENTIAL JOINTS BUTTED AND LONGITUDINAL JOINTS OVERLAPPED A MINIMUM OF 2". ADHERE INSULATION WITH 4" STRIPS OF INSULATION BONDING ADHESIVE AT 8" CENTERS. FIBERGLASS SERIES ED- 100 OR EQUAL. AIR DISTRIBUTION: 1.AIR DISTRIBUTION DEVICES; AMCA CERTIFIED PERFORMANCE RATINGS, NOISE LEVELS NOT TO EXCEED NC- 35. STEEL ITEMS SHALL BE FINISHED WITH FACTORY APPLIED WHITE BAKED ENAMEL. CARNES, TITUS, TUTTLE & BAILEY, KRUGER, ANEMOSTAT. 2.MANUFACTURER'S NAMES AND CATALOG NUMBERS INDICATES MATERIALS ACCEPTED BY THE ENGINEER. SUBMIT SUBSTITUTES OF EQUIVALENT MATERIALS OF- SIMILAR QUALITY, THE SAME 3.OR BETTER WITH RESPECT TO STYLE AND FUNCTION, FOR REVIEW AND ACCEPTANCE, STATE PROPOSED EXCEPTIONS TO REQUIREMENTS CLEARLY IN ONE PLACE, INCLUDING REQUIRED RELATED CHANGES TO BUILDING SYSTEMS, OPERATING PROCEDURES, AND MAINTENANCE FUNCTIONS. HVAC EQUIPMENT: 1.EXISTING 2 TON UNIT - ROOFTOP EQUIPMENT- TO BE FIELD VERIFIED AS TO LOCATION. 2.GC SHALL PROVIDE NEW SUPPLY AND RETURN DUCTWORK AS SHOWN. REUSE SUPPLY AND RETURN DUCTWORK WHEN POSSIBLE. CODES: 1.THE ENTIRE INSTALLATION SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE, MECHANICAL CODE AND ALL LOCAL ADOPTED AMENDMENTS AND ORDINANCES. REFER TO THE ARCHITECTURAL COVER SHEET CODE REFERENCE FOR REFERENCED CODES. LAY-IN HVAC SUPPLY DIFFUSER. CONNECT TO TRUNK LINE ABOVE PER CODE. 24X24 TITUS OMNI OR EQ. THERMASTAT - MOUNT AT 48" A.F.F. FLEX DUCT RUN OUT TO DIFFUSER/RETURN LAY-IN HVAC SUPPLY DIFFUSER. CONNECT TO TRUNK LINE ABOVE PER CODE. 24X24 TITUS OMNI OR EQ. 14x12 14x12 RTU 200 CFM 8" Ø 200 CFM 8" Ø 200 CFM 8" Ø 200 CFM 8" Ø 10"Ø10"Ø 10x10 OUT OF SCOPE OF WORK 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : 45456 P R O F E S IONA L R E GIS T E R E D E N G INEER STA O F T E H N G JUS T I N R.H A R D Y WAS I T O N S M1.0 INSULATED FLEX DUCT SUPPORT STRAP CEILING T-BAR FRAME (TYP.)- PROVIDE METAL HANGER (TYP.) INSULATED SUPPLY ADAPTER/PLENUM PLANS LOCKING QUADRANT FOR SIZE SEE SPIN-IN FITTING WITH VOLUME DAMPER METAL DUCT DIFFUSER / RETURN DETAIL DEVICE NECK SIZE TO MATCH RUN OUT AIR SCOOP FRAME AT GYP INSTALLTIONS STEEL WIRE TO STRUCTURE (SUPPLY ONLY) MFG ACCESSORY FLAT OVAL CONNECTION HARD TRANSITION FLEX DUCT (3') ADJUST DIRECTIOAN BLADES FOR SIDEWAYS DISCHARGE SEE PLANS FOR AIRFLOW DIRECTION. SLOT DIFFUSER DETAIL HARD DUCT TO MAIN WITH SPIN-IN, SCOOP AND DAMPER LINED PLENUM MECHANICAL PLAN ɸ J E1.0 ELECTRICAL POWER PLAN 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : 50664 P R O F E S IONA L R E GIS T E R E D E N G IN EER STA O F T E H N G GUID O I N OA AL V A R E Z WAS I T O N S COMcheck Software Version 4.1.5.5 Interior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Construction Site: SAFEWAY #1619 1109 E YELM AVE YELM, WA 98597 Owner/Agent:Designer/Contractor: WILMAN DIAZ CONVERGE ENGINEERING Project Information Energy Code: Twin Star Credit Union Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Retail 460 0.95 439 Total Allowed Watts =439 Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Retail LED 1: A: DOWN LIGHT: Other:1 6 16 97 LED 2: A2: DOWNLIGHT: Other:1 1 10 10 LED 3: B: LINEAR LED: Other:1 4 50 200 LED 4: C: 2X2 PANEL LED: Other:1 2 16 32 LED 5: D: IN COVE: Other:1 23 1 31 LED 6: E-30": LED UC LIGHT BAR: Other:1 1 7 7 Total Proposed Watts =377 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 14% better than code Project Title: Data filename: Twin Star Credit Union S:\Shared Folders\PROJECTS\2024\241272-US-FSI TwinStar Credict Union - Yelm, WA\Drawings\FSI-Twin Star , WA.cck Report date: 10/11/24 Page 1 of 6 Wilman Diaz 10/11/2024 ELECTRICAL LIGHTING PLAN 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : 50664 P R O F E S IONA L R E GIS T E R E D E N G IN EER STA O F T E H N G GUID O I N OA AL V A R E Z WAS I T O N S E2.0SCALE: 1 E2.0 ELECTRICAL LIGHTING PLAN 1/2" = 1'-0" 1 FP1 FIRE PROTECTION PLAN 1/2" = 1'-0" NEW REPOSITION REPOSITION REPOSITION REPOSITION OUT OF SCOPE OF WORK 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : 45456 P R O F E S IONA L R E GIS T E R E D E N G INEER STA O F T E H N G JUS T I N R.H A R D Y WAS I T O N S FIRE PROTECTION PLAN FP1 1.BIDDING CONTRACTORS MUST REVIEW ALL DRAWINGS, CONSTRUCTION DOCUMENTS AND SPECIFICATION PRIOR TO BID. 2.FIRE SPRINKLER CONTRACTOR'S START POINT SHALL BE AT THE LARGEST PIPING MAIN SERVING THIS AREA, REUSING EXISTING MAINS, HEADS, AND BRANCHES WHERE POSSIBLE AND PROVIDING NEW BRANCHES AS REQUIRED FOR NEW HEAD LAYOUT. 3.SELECTED CONTRACTOR SHALL PREPARE FIRE SPRINKLER SHOP DRAWINGS AND HYDRAULIC CALCULATIONS IN ACCORDANCE WITH NFPA 13, AND FIRE SPRINKLER SPECIFICATION. FIRE SPRINKLER CONTRACTOR SHALL CONFIRM THE OCCUPANCY OF EACH SPACE PRIOR TO START OF WORK TO DETERMINE THE OCCUPANCY CLASSIFICATION. DRAWINGS SHALL BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION. FABRICATION AND INSTALLATION SHALL NOT COMMENCE WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER PRIOR TO OBTAINING APPROVED SHOP DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CURRENT FLOW TEST FOR THE HYDRAULIC CALCULATIONS. 4.DESIGN , MATERIALS, AND INSTALLATION SHALL CONFORM TO THE APPLICABLE CODES AS SHOWN, THE LOCAL FIRE DEPARTMENT (AHJ). 5.ALL MATERIALS USED SHALL BE UL LISTED AND FM APPROVED. 6.SPRINKLER PIPE SHALL BE PER NFPA STANDARDS, ACCORDING TO THEIR LISTINGS. ALL PIPING SHALL HAVE A CORROSION RESISTANT RATIO OF 1.0 OR GREATER. CRIMP TYPE INSTALLATIONS ARE NOT ACCEPTABLE. 7.CONTRACTOR TO PROVIDE ACCESS PANELS FOR ALL VALVES IN CONCEALED SPACES. 8.CONTRACTOR TO LABEL ALL SPRINKLER PIPING .. 9.THE CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR SHALL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS THE DESIGN PROFESSIONAL FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 10.THE FIRE PROTECTION ENGINEER OF RECORD SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE CONSTRUCTION WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, NOR SHALL THEY BE REQUIRED TO SUPERVISE THE CONDUCT OF THE WORK, THE CONSTRUCTION PROCEDURES FOLLOWED BY RESPECTIVE ANY PERSON OTHER THAN THE ENGINEERING FIRMS EMPLOYEES. 11.THE INSTALLING FIRE SPRINKLER CONTRACTOR SHALL PERFORM ALL FIRE PROTECTION AND RELATED SYSTEMS ACCEPTANCE TESTING TO BE WITNESSED BY OWNERS CONSULTANT. TESTING WILL OCCUR AFTER INSTALLATION OF ALL SYSTEMS HAVE BEEN COMPLETED. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE A LIFT, AIR AND WATER PUMPS FOR SYSTEM PRESSURIZATION, AND ANY NECESSARY HAND TOOLS AND APPARATUS FOR COMPLETE TESTING AND DRAINING OF THE SYSTEMS. ONE TEST OF ALL SYSTEMS SHOULD BE COMPLETED WITHIN (1) DAY. IF ALL OR ANY SYSTEM SHOULD FAIL, THE CONTRACTOR SHALL BE RESPONSIBLE TO BE PRESENT AND FURNISH ALL ITEMS LISTED ABOVE UNTIL SUCH TIME THAT THE SYSTEMS ARE FOUND ACCEPTABLE AND IN ACCORDANCE WITH NFPA 13,, 25, BUILDING AND FIRE CODES (INCLUDING LOCAL ORDINANCES) AND THE BID DOCUMENTS. 12.ALL SPRINKLER HEADS TO BE PENDANT MOUNT.