Loading...
Plans Civil STC LD20220109929394 84 696168606766 58 65 TRACT 'E' 6463 7062 2 TRACT 'G' 42 41 46 47 TR A C T ' D ' 71 TR A C T ' C ' 83 72 80 TRACT 'B' 82 81 TRACT 'J' TRACT 'A' 79 76 77 78 74 75 73 24 1 21 22 108 106 105 53 54 56 57 28 31 25 TRACT 'I' 5150 49 59 91 89 88 87 85 97 18 23 8690 38 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 TRACT 'K' 52 3 102 100 99 9596 103 98 101 36 37 35 14 6 13 5 12 4 11 10 9 16 8 15 7 17 31 36 37 39 40 35 34 33 32 30 14 20 13 19 12 11 10 9 8 15 7 29 27 26 13 12 11 10 9 8 7 17 31 27 26 28 31 21 18 38 36 37 39 40 35 34 33 32 30 14 6 20 13 5 19 12 4 11 10 9 16 8 15 7 17 29 27 26 17 6 9 18 38 11 JA C K S O N S T S E 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-COVER.dwg C0.1 1 COVER SHEET N GRAPHIC SCALE 0 120 240 1" = 120 FEET 60 AHBL ENGINEERS, PLANNERS, & SURVEYORS 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 CONTACT: SCOTT KAUL, P.E. COPPER RIDGE, LLC P.O. BOX 73790 PUYALLUP, WA 98373-0790 CONTACT: MR. KURT WILSON AHBL ENGINEERS, PLANNERS, & SURVEYORS 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 CONTACT: DAVE FOLLANSBEE, PLS. TOPOGRAPHIC SURVEY WAS PREPARED BY AHBL, INC. FIELD DATA WAS COLLECTED IN APRIL 2023. NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. NAD 1983/11 WASHINGTON STATE PLANE SOUTH PROJECTION, BASED ON GPS OBSERVATION USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. SEE SHEET C0.2 - EXISTING CONDITIONS FOR LEGAL DESCRIPTION PARCEL NUMBERS:21724230100, 21723140000, 21723140102 ADDRESS:14444 BERRY VALLEY RD SE YELM WA, 98597 SITE AREA:1,505,994 SF (34.57 ACRES) (AFTER PROPOSED BLA) EXISTING ZONING:R-4, RESIDENTIAL N EXISTING DESCRIPTION PROPOSED LEGEND SITE DATA LEGAL DESCRIPTION BASIS OF BEARING VERTICAL DATUM DEVELOPER CIVIL ENGINEER SURVEYOR VICINITY MAP NOT TO SCALE SITE AREA 1,505,994 SF (34.57 AC) (AFTER PROPOSED BLA) MAX. DENSITY (4 DU) = 138.28 UNITS (USE 138 UNITS) PROPOSED DENSITY = 109 UNITS GROSS DEVELOPABLE ACREAGE X ALLOWED DENSITY IN DWELLING UNITS = ALLOWABLE NUMBER OF DWELLING UNITS CUT = 92,250 CU. YDS FILL = 81,750 CU. YDS NET = 10,500 CU. YDS EXPORT NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS. DO NOT USE FOR BID PURPOSES. THE QUANTITIES DO NOT HAVE STRIPPING, COMPACTION, OR CUT OR FILL ADJUSTMENT FACTORS APPLIED TO THEM, NOR DO THEY ACCOUNT FOR ROADWAY SECTION. THE WETLAND DELINEATION AND STREAM ASSESSMENT REPORT PREPARED BY LAND SERVICES NORTHWEST IDENTIFIES THREE WETLANDS AND A TYPE F STREAM ON THE PROJECT SITE. THE DELINEATED WETLANDS AND STREAM WITH ASSOCIATED BUFFERS ARE SHOWN IN THIS PLAN SET. SITE PROJECT SITE SCALE 1"=120' WETLAND DELINEATION EARTHWORK QUANTITIES DENSITY CALCULATIONS 21723140102 EVANS, JEFFREY B CEMENT CONC. PAVEMENT NATURAL GAS LINE CONIFER TREE DECIDUOUS TREE ASPHALT CONC. PAVEMENT STANDARD DUTY PAVING SANITARY SEWER LINE STORM DRAIN LINE POWER/TELE. POLE CHAIN LINK FENCE FIRE SERVICE WATER LINE CONTOURS WIRE FENCE WOOD FENCE WATER METER WATER VALVE SIGN HYDRANT STORM DRAIN MH SANITARY SEWER MH CATCH BASIN TELEPHONE MH TELEPHONE RISER GUY WIRE LIGHT W D ELEV D W SS F ELEV G LAND SERVICES NORTHWEST 120 STATE AVENUE, NE PMB 190 OLYMPIA, WA 98501 PH. (360) 481-4208 CONTACT: ALEX CALLENDER, MS PWS WETLAND BIOLOGIST BOUNDARY LINE PER BLA22-0109YL BLAM 5010000 EXISTING WELL SETBACK RO A D 3 21723110300 MOSS, WILLIAM R & DEBRA A 21724220200 VALENZUELA, MICHAEL LAWRENCE 21724210500 SCHOOL DISTRICT #2 21 7 2 4 2 3 0 1 0 1 JE N K I N S , T A M M Y M 21724230105 KIMBROUGH, WILBERT L 21724230200 HOBART, DELYNN B 21724230900 SOETEBER, MARK W 21724230400 GERRISH FAMILY REVOCABLE LIVING TRUST DA I N S T . S E 78640100019 TAHOMA TERRA HOLDINGS LLC 21723420000 DDD WASHINGTON LLC 21723130000 DDD WASHINGTON LLC 21723120400 HUDDLESTON, JOE D 21724230100 PURVIS, DAVID A 21723140000 PURVIS, DAVID A EXISTING INGRESS/EGRESS & UTILITY EASEMENT (TO BE VACATED) EXISTING UTILITY EASEMENT (TO BE VACATED)EXISTING WELL TO BE ABANDONED 21723140101 (FOR TAX PURPOSES) BERRY VALL E Y R O A D S E ROAD 1 JAC K S O N S T . S E ROAD 2 BERRY VALLEY ROAD SE Sheet List Table Sheet Number Sheet Title C0.1 COVER SHEET C0.2 EXISTING CONDITIONS C1.2 PLAT MAP (NE) C1.3 PLAT MAP (NW) C1.4 PLAT MAP (S) C2.1 TESC AND DEMOLITION PLAN C2.2 TESC AND DEMOLITION PLAN C2.3 TESC NOTES AND DETAILS C2.4 TESC NOTES AND DETAILS C3.0 OVERALL GRADING PLAN C3.1 GRADING AND ROOF DRAINAGE PLAN (NE) C3.2 GRADING AND ROOF DRAINAGE PLAN (NW) C3.3 GRADING AND ROOF DRAINAGE PLAN (S) C3.4 BERRY VALLEY ROAD C3.5 BERRY VALLEY ROAD C3.6 JACKSON STREET PLAN & PROFILE C3.7 JACKSON STREET PLAN & PROFILE C3.8 ROAD 1, ROAD 2 & ROAD 3 PLAN & PROFILE C3.9 ROAD SECTIONS C3.10 ROAD SECTIONS C3.11 THOMPSON CREEK CROSS SECTIONS C3.12 THOMPSON CREEK CROSSING DETAILS C4.1 INTERSECTION DETAILS C4.2 INTERSECTION DETAILS C4.3 INTERSECTION DETAILS C4.4 PUBLIC ROAD NOTES & DETAILS C4.5 PUBLIC ROAD NOTES & DETAILS C4.6 PUBLIC ROAD NOTES & DETAILS C5.1 TRACT E STORM POND PLAN & PROFILE C5.2 TRACT F STORM POND PLAN & PROFILE C5.3 TRACT A BIORETENTION POND PLAN & PROFILE C5.4 TRACT K STORM POND PLAN & PROFILE C5.5 STORM DRAINAGE NOTES AND DETAILS C5.6 STORM DRAINAGE NOTES AND DETAILS C5.7 STORM DRAINAGE NOTES AND DETAILS C5.8 ON LOT INFILTRATION PLAN C6.0 OVERALL UTILITY MAP C6.1 UTILITY MAP (NE) C6.2 UTILITY MAP (NW) C6.3 UTILITY MAP (S) C7.1 BERRY VALLEY ROAD WATER PLAN & PROFILE C7.2 BERRY VALLEY ROAD WATER PLAN & PROFILE C7.3 JACKSON STREET WATER PLAN & PROFILE C7.4 JACKSON STREET WATER PLAN & PROFILE C7.5 ROAD 1, ROAD 2 & ROAD 3 WATER PLAN & PROFILE C7.6 WATER NOTES & DETAILS C7.7 WATER NOTES & DETAILS C8.1 BERRY VALLEY ROAD STEP PLAN & PROFILE C8.2 JACKSON STREET STEP PLAN & PROFILE C8.3 JACKSON STREET STEP PLAN & PROFILE C8.4 ROAD1, ROAD 2, & ROAD 3 STEP PLAN & PROFILE C8.5 SEWER STEP NOTES AND DETAILS C8.6 SEWER STEP NOTES AND DETAILS C9.1 WETLAND BUFFER AVERAGING PLAN SEE OFFSITE SET #______ FOR IMPROVEMENTS ON BERRY VALLEY RD WETLAND RESOURCES, INC. 9505 19TH AVE SE, SUITE 106 EVERETT, WA 98208 CONTACT: JEFF MALLAHAN (SENIOR ECOLOGIST) STORM CROSSING - HPA PERMIT TEMPORARY CONSTRUCTION EASEMENT PER TC REC. NO. 5028283 10/09/2024 BOUNDARY LINE AFTER PROPOSED BLA JA C K S O N S T S E 21723140102 EVANS, JEFFREY B 21723110300 MOSS, WILLIAM R & DEBRA A 21724220200 VALENZUELA, MICHAEL LAWRENCE 21724210500 SCHOOL DISTRICT #2 21 7 2 4 2 3 0 1 0 1 JE N K I N S , T A M M Y M 21724230105 KIMBROUGH, WILBERT L 21724230200 HOBART, DELYNN B 21724230900 SOETEBER, MARK W 21724230400 GERRISH FAMILY REVOCABLE LIVING TRUST DA I N S T . S E 78640100019 TAHOMA TERRA HOLDINGS LLC 21723420000 DDD WASHINGTON LLC 21723130000 DDD WASHINGTON LLC 21723120400 HUDDLESTON, JOE D 21724230100 PURVIS, DAVID A 21723140000 PURVIS, DAVID A 21723140101 (FOR TAX PURPOSES) DATE: May 2, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-EXST-COND.dwg C0.2 2 EXISTING CONDITIONS N GRAPHIC SCALE 0 120 240 FEET 1" = 120 FEET 600 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX PARCEL A: LOT A OF BOUNDARY LINE ADJUSTMENT NO. BLA-99-8233-YL, AS RECORDED ON JULY 13, 2000 UNDER RECORDING NOS. 3302940 AND 3302942; PARCEL B: THAT PART OF THE SOUTHWEST QUARTER OF THE NORTHWEST QUARTER OF SECTION 24, TOWNSHIP 17 NORTH, RANGE 1 EAST LYING NORTHERLY OF A LINE RUNNING FROM A POINT ON THE WEST LINE OF SAID SUBDIVISION THAT IS 406 FEET SOUTH OF ITS NORTHWEST CORNER TO A POINT ON THE EAST LINE OF SAID SUBDIVISION THAT IS 312 FEET SOUTH OF ITS NORTHEAST CORNER; EXCEPT THE EAST 400 FEET THEREOF; AND EXCEPT THAT PORTION, IF ANY, CONVEYED TO THURSTON COUNTY FOR ROAD PURPOSES DESCRIBED IN DEEDS RECORDED NOVEMBER 19, 1969 AND FEBRUARY 2, 1992 UNDER AUDITOR'S FILE NOS. 812829, 9202070138, AND 9202070139; AND BEGINNING AT A POINT ON THE EAST LINE OF THE SOUTHWEST QUARTER OF THE NORTHWEST QUARTER OF SECTION 24, TOWNSHIP 17 NORTH, RANGE 1 EAST, W.M., SOUTH 01°02'46" WEST 266.97 FEET FROM THE NORTHEAST CORNER THEREOF; THENCE SOUTH 80°25'13" WEST TO INTERSECT THE SOUTH LINE OF THAT CERTAIN PARCEL CONVEYED TO JOSEPH H. CLARAMBEAU AND RECORDED UNDER AUDITOR'S FILE NO. 215228, AND THE TRUE POINT OF BEGINNING OF THIS DESCRIPTION; THENCE CONTINUING SOUTH 80°25'13" WEST TO THOMPSON CREEK, THENCE NORHWESTERLY ALONG THOMPSON CREEK TO SAID SOUTH LINE OF SAID 20 FOOT WIDE STRIP RESERVED BY DEED RECORDED UNDER AUDITOR'S FILE NO. 215228; THENCE EASTERLY ALONG SAID SOUTH LINE TO THE TRUE POINT OF BEGINNING; EXCEPT THAT PORTION, IF ANY, CONVEYED TO THURSTON COUNTY FOR ROAD PURPOSES DESCRIBED IN DEEDS RECORDED NOVEMBER 19, 1969 AND FEBRUARY 2, 1992 UNDER AUDITOR'S FILE NOS. 812829, 9202070138, AND 9202070139; PARCEL C: LOT B OF BOUNDARY LINE ADJUSTMENT NO. BLA-99-8233-YL, AS RECORDED ON JULY 13, 2000 UNDER RECORDING NOS. 3302940 AND 3302942; EXCEPT ANY MOBILE HOMES LOCATED THEREON; IN THURSTON COUNTY, WASHINGTON LEGAL DESCRIPTION DECOMMISSION WELLS AND SEPTIC SYSTEM 10/09/2024 4000 S.F. 92 4000 S.F. 93 4000 S.F. 94 5500 S.F. 84 5000 S.F. 69 5000 S.F. 68 5000 S.F. 67 5000 S.F. 66 5000 S.F. 65 4000 S.F. 64 4000 S.F. 63 5000 S.F. 70 20 3 8 S . F . TR A C T ' D ' 4003 S.F. 71 35 9 1 S . F . TR A C T ' C ' 5499 S.F. 83 4071 S.F. 72 4500 S.F. 80 15145 S.F. TRACT 'B' 7447 S.F. 82 4500 S.F. 81 244050 S.F. TRACT 'J' 13332 S.F. TRACT 'A' 4200 S.F. 79 4000 S.F. 76 4000 S.F. 77 4000 S.F. 78 5226 S.F. 74 4002 S.F. 75 7389 S.F. 73 40.00' 10 0 . 0 0 ' 40.00' 40.00' 10 0 . 0 0 ' 40.00' 50.00' 10 0 . 0 0 ' 50.00' 50.00' 10 0 . 0 0 ' 50.00' 50.00' 10 0 . 0 0 ' 50.00' 50.00' 10 0 . 0 0 ' 50.00' 50.00' 10 0 . 0 0 ' 50.00' 50.00' 10 0 . 0 0 ' 50.00' 15 .2 9 ' 24.73' 40.00' 10 0 . 6 6 ' 28.8 2 ' 18.97' 10 3 . 4 8 ' 40.00' 88 . 9 1 ' 6 2 . 7 7 ' 111 . 1 5 ' 33.36' 51.04' 5 0 . 0 0 ' 100 . 4 1 ' 5 1.3 2' 4 0 . 0 0 ' 100 . 0 0 ' 2 7 . 9 9 ' 12 . 0 2 ' 4 0 . 0 0 ' 100 . 0 0 ' 4 0 . 0 0 ' 4 0 . 0 0 ' 100 . 0 0 ' 4 0 . 0 0 ' 4 0 . 0 0 ' 100 . 0 0 ' 4 0 . 0 0 ' 4 0 . 0 0 ' 105 . 0 0 ' 4 0 . 0 0 ' 5.00' 4 5 . 0 0 ' 100 . 0 0 ' 4 5 . 0 0 ' 100 . 0 0 ' 4 5 . 0 0 ' 4 5 . 0 0 ' 100 . 0 0 ' 4 5 . 2 9 ' 2 4 . 9 7 ' 11 9 . 0 0 ' 73.3 7' 9 .9 5' 99 . 5 9 ' 55.00' 10 0 . 0 0 ' 45.06'55.00' 55.00' 10 0 . 0 0 ' 5.64' 69 . 4 1 ' 39 . 2 7 '37.40' 61.77' 3 1 . 8 0 ' 1 4 . 0 1 ' 40 . 0 0 ' 150.97' 7 9.3 7'42 . 6 6 ' 193.95' 11.51' 5 6.30' 169.72'4 0 . 0 0 ' 124.59' 3 6 . 4 0 ' 3 6 . 7 2 ' 3 6 . 7 2 ' 122.81' 31.80' 4 0 . 3 6 ' 13.61'40.00'40.00'55.37' 1 4.01' 5.64' 10 0 . 0 0 ' 31.00'39. 2 7 ' 69 . 4 1 ' 40.00' 10 0 . 0 0 ' 40.00' 10 0 . 0 0 ' 40.00' 26.39' 10 0 . 0 0 ' 50.45' 2 2 . 2 3 ' 1 1 3 . 2 2 ' 6 4 . 0 5 ' 11.60' 41.50' 111.74' 7 4 . 9 3 ' 52. 4 5' 239.59' 69 . 5 7 ' 57 . 2 5 ' 20.30' 20.18' 20.22' 13.45' 6.55' 34 5 . 0 2 ' 825.25' 250.37' 49 . 7 3 ' 165.43' 139.19' 5 4 . 7 2 ' 91.00' 5 4 . 5 5 ' 91.00' 5465 S.F. 91 5286 S.F. 89 5867 S.F. 88 8819 S.F. 87 6105 S.F. 85 6403 S.F. 865384 S.F. 90 4972 S.F. TRACT 'K' 1.00' RO A D 3 (L O C A L AC C E S S R E S . ) BERRY VALLEY ROAD SE (NEIGHBORHOOD COLLECTOR) N88° 17' 08"W922.84' N1 ° 1 7 ' 0 1 " E 34 5 . 0 2 ' S80° 39' 28" W 369.12' N87° 39' 50"E 555.81' N1 ° 0 6 ' 0 0 " E 98 4 . 9 9 ' N88° 41' 33"W1323.48' S83° 40' 08"W 434.28' S83° 40' 08"W 55.20' 1 0 1 . 0 0 ' 28 . 0 0 ' 25.50'30.50' 5 6 . 0 0 ' 2 8 . 0 0 ' 56 . 0 0 ' 28 . 0 0 ' 1 1 1 25.00'25.00' S88° 41' 33"E 415.77'S88° 41' 33"E 192.96' 2+ 0 0 N1 ° 1 8 ' 2 7 " E 17 5 . 4 7 ' 4+00 5+00 6+00 7+00 8 + 0 0 9 + 0 0 1 0 + 0 0 11 + 0 0 12+00 13 + 0 0 14+00 15+00 16+00 17+00 18+00 STA: 5+15.77 BERRY VALLEY= STA: 2+75.47 ROAD 3 L=127.40'R =15 0.0 0' Δ=48°39'43" S 4 0 ° 0 1 ' 5 0 " E 2 1 0 . 2 2 ' L = 1 2 9.93'R =200.00' Δ = 3 7°13'25" S77° 1 5 ' 1 5 " E 78.55' Δ=16°53'15" R=150.00' L=44.21' S60° 22' 00"E 4.78' L=102.31'R=150.0 0 ' Δ=39°04'51" N80° 33' 09" E 699.02' PC STA:14+06.13 PC STA:13+03.82 PC STA:12+99.04 PC STA:12+54.83 PC STA:11+76.28 PC STA:10+46.34 PC STA:8+36.13 PC STA:7+08.73 3+003+00 N83° 40' 08"E 15.71' STA: 14+37.61 JACKSON= 60' AC C E S S E A S M E N T P E R AFN 91 0 5 1 6 0 1 0 9 250' BY 80' INGR E S S / E G R E S S A N D UTILITY EASEM E N T P E R B L A 3302942 40' UTILITY EASMENT PER AFN 9206010033 60 ' 40 ' 20 ' 60' ACCESS ROAD EASEMENT A.F.N. 9105160109 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX SE E S H E E T C1 . 3 DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-PLAT-MAP.dwg C1.2 3 PLAT MAP (NE) PROPOSED ACCESS EASEMENT EXISTING PARCEL LINE 150 . 0 0 ' 150 . 0 0 ' WETLAND BUFFER WETLAND BUFFER EDGE OF WETLAND (THOMPSON CREEK) BUILDING SETBACK (TYP.) 10' UTILITY EASEMENT (TYP.) 56.00' R50' R 2 5 ' ( T Y P . ) 21723140102 EVANS, JEFFREY B 21724220200 VALENZUELA, MICHAEL LAWRENCE 21 7 2 4 2 1 0 5 0 0 SC H O O L D I S T R I C T # 2 21 7 2 4 2 3 0 1 0 1 JE N K I N S , T A M M Y M 21724230105 KIMBROUGH, WILBERT L 21724230200 HOBART, DELYNN B 21724230900 SOETEBER, MARK W 21724230400 GERRISH FAMILY REVOCABLE LIVING TRUST 21723110300 MOSS, WILLIAM R & DEBRA A STATISTICAL BREAKDOWN ITEM DESCRIPTION OR AREA SQUARE FEET ACRES SITE AREA (AFTER PROPOSED BLA)1,505,994 CRITICAL AREAS PROPOSED ONSITE ROAD ROW GROSS DEVELOPMENT AREA EXISTING & PROPOSED ZONING: 421,115 206,293 1,505,994 R-4, RESIDENTIAL MAXIMUM DENSITY (4 DU/ACRE) TOTAL NO. OF LOTS PROPOSED (SINGLE FAMILY) LARGEST LOT AREA (LOT 77) SMALLEST LOT AREA (MULTIPLE LOTS) AVERAGE LOT AREA OPEN SPACE (NOT INCLUDING WETLAND AREA) (28.93%) TOTAL IMPERVIOUS SURFACE (31.09%) ROAD ROW ROOF AREA (2,200 SF AVG. x 109 UNITS) 34.57 9.67 109 4.74 34.57 138.28 (USE 138) 8,819 4,000 0.20 0.09 5,297 0.12 435,269 9.99 3.90 58,500 1.34 468,222 10.75 169,922 239,800 5.51 TRACT IDENTIFICATION SQUARE FEET ACRES 13,332 0.31 ITEM TRACT 'A' - STORM DRIVEWAYS (500 SF x 107 UNITS + 2,500 SF x 2 UNITS) LOT SETBACKS - SINGLE FAMILY FRONT YARD LOCAL ACCESS 15 FT NEIGHBORHOOD COLLECTOR 25 FT MIN. DRIVEWAY APPROACH 20 FT SIDE YARD 5 FT 15 FT (CORNER LOT) REAR YARD 25 FT 15,145 0.35TRACT 'B' - OPEN SPACE 3,591 0.08TRACT 'C' - UTILITY 2,038 0.05TRACT 'D' - UTILITY 48,200 1.11TRACT 'E' - STORM 45,804 1.05TRACT 'F' - STORM 115,117 2.64TRACT 'G' - CRITICAL AREA/OPEN SPACE INGRESS/EGRESS EASEMENT (TO BE VACATED) 6 0 . 0 0 ' 8,288 0.19TRACT 'H' - ACCESS 221,834 5.09TRACT 'I' - CRITICAL AREA/OPEN SPACE 241,621 5.55TRACT 'J' - CRITICAL AREA/OPEN SPACE TRACT 'K' - STORM 7,400 0.17 KEYNOTES: 2' ROOF DRAIN EASEMENT1 ACCESS EASEMENT TO BE VACATED 21724230105 KIMBROUGH, WILBERT L 10/09/2024 6 0 ' 5836 S.F. 51 5929 S.F. 50 5935 S.F. 49 5914 S.F. 108 5590 S.F. 106 5320 S.F. 105 5045 S.F. 53 5047 S.F. 54 5050 S.F. 56 5050 S.F. 57 4000 S.F. 94 4000 S.F. 61 4000 S.F. 60 5050 S.F. 58 48074 S.F. TRACT 'E' 4000 S.F.4000 S.F. 63 4000 S.F. 62 5050 S.F. 2 115117 S.F. TRACT 'G' 5800 S.F. 42 5800 S.F. 41 5389 S.F. 46 5220 S.F. 47 5050 S.F. 1 1 0 1 . 0 0 ' 50.00' 1 0 1 . 0 0 ' 50.00' 50.00' 1 0 1 . 0 0 ' 44.73' 31.00' 3 9 .27' 7 6 . 0 0 ' 56.00' 92 . 1 3 ' 110.2 6 ' 3 2 .0 6 ' 87.29' 25.8 1 ' 24.1 9 ' 37. 5 9 ' 10 0 . 0 5 ' 1 0 5 . 3 1 ' 50. 0 0 ' 1 1 6 . 0 0 ' 50. 0 0 ' 1 1 6 . 0 0 ' 50. 0 0 ' 1 1 5 . 8 8 ' 81.6 8 ' 1 0 5 . 0 0 ' 1 0 3 . 4 5 ' 50. 0 0 ' 1 0 1 . 9 4 ' 5.85' 50. 0 0 ' 1 0 7 . 7 9 ' 50.4 6 ' 1 0 1 . 0 0 ' 53. 1 1 ' 1 0 1 . 1 6 ' 7 .0 9 ' 4 9 .7 8 ' 71.4 3 ' 9 7 . 6 7 ' 4 9 .7 8 ' 4.57' 66.83 ' 1 0 1 . 0 0 ' 4 7 .3 3 ' 68.44' 1 0 3 . 2 9 ' 10 0 . 8 8 ' 21.54' 2 6 .81' 60.40' 10 0 . 9 1 ' 50.00' 50.00' 10 0 . 9 5 ' 50.00' 50.00' 26 . 9 7 ' 4 6 . 8 8 ' 4 1 . 4 9' 37.18' 60.00' 50 . 0 0 ' 101.00' 50 . 0 0 ' 101.00' 50 . 0 0 ' 50 . 0 0 ' 101.00' 101.00' 50 . 0 0 ' 50 . 0 0 ' 56.00' 10 0 . 0 0 ' 31.00' 3 9 .2 7' 75 . 0 0 ' 40.00' 10 0 . 0 0 ' 40.00' 40.00' 10 0 . 0 0 ' 40.00' 40.00' 10 0 . 0 0 ' 40.00' 40.00' 10 0 . 0 0 ' 40.00' 40.00' 40.00' 4 0 . 0 0 ' 3 6 . 7 2 ' 3 6 . 7 2 ' 4 0 . 3 6 ' 13.61' 10 0 . 0 0 ' 40.00' 26.39' 10 0 . 0 0 ' 40.00' 10 5 . 3 6 ' 40.50' 39.20' 40 . 0 0 ' 58 . 2 7 ' 80.77' 105.09' 2 8 . 7 0 '10 . 9 7 ' 39.2 7 ' 100.73' 1 3 . 0 7 ' 3 4 . 2 2 ' 4 3 . 1 0 ' 4 0 . 0 0 ' 4 0 . 0 0 ' 4 0 . 0 0 ' 100.73' 1 3 . 0 0 ' 206.45' 1 3 . 0 0 ' 100.73' 4 3 . 1 0 ' 50.45' 7 8 . 9 1 ' 41.83' 1 0 4 . 0 1 ' 34.63'35.9 4 ' 8.20' 1 0 8 . 9 4 ' 50.45' 50.01' 1 1 4 . 6 5 ' 50.45' 50.01' 1 1 9 . 8 3 ' 13 .5 3 ' 36.86' 50.01' 1 1 4 . 2 4 ' 5 0 .3 9 ' 7 2 .4 6 ' 40. 3 1 ' 326.39' 15 . 0 0 ' 76 . 9 5 ' 2 7 . 5 1 ' 9 4 . 7 1 ' 5 3 . 1 6 ' 9 3 . 8 0 ' 27. 7 1 ' 6 6 . 1 8 ' 133.7 7 ' 56 5 . 4 9 ' 230.63' 164.6 2 ' 65 . 6 9 ' 55.20' 7 9.7 4 '2 3 .6 4 ' 23. 3 2 ' 50. 0 0 ' 50. 0 0 ' 42. 8 8 ' 39. 9 8 ' 50. 0 0 ' 50. 0 0 ' 27. 3 5 ' 1 5 .18 '7.53' 9.34' 5 4.0 9' 39.0 7 ' 6 1 . 8 7 ' 6 7 . 6 4 ' 9 5 . 9 8 ' 19.07' 5 4 . 1 7 ' 56.00'4.28' 56.00' 5466 S.F. 59 4493 S.F. 98 6361 S.F. 97 5288 S.F. TRACT 'L' 5756 S.F. 104 5873 S.F. 107 8112 S.F. 109 5805 S.F. 43 5206 S.F. 48 6016 S.F. 55 7137 S.F. 45 8288 S.F. TRACT 'H' 7387 S.F. 44 5 6 . 0 0 ' 5508 S.F. 52 1 2 . 4 2 ' 2 7 . 5 8 ' 40.36' 1.00' 5522 S.F. 3 7189 S.F. 102 4341 S.F. 103 4029 S.F. 100 4029 S.F. 99 4107 S.F. 95 4367 S.F. 96 9782 S.F. 101 10.69' 48.74' 40.33' 33.13' 7 . 9 1 ' 4 . 5 9 ' 111.68' 7511 S.F. 4 5288 S.F. 40 J A C K S O N S T . S E ( L O C A L A C C E S S R E S . ) ROAD 2 (LOCAL ACCESS RES.) BERRY VALLEY ROAD SE (NEIGHBORHOOD COLLECTOR) ROAD 1 (LOCAL ACCESS RES.) N88° 41' 33"W1323.48' S1 ° 1 4 ' 5 9 " W 13 2 4 . 4 4 ' S6 ° 2 5 ' 4 7 " W S83° 40' 08"W 55.20' S 6 ° 1 9 ' 5 2 " E 1 0 1 . 0 0 ' 11 + 0 0 1 2 + 0 0 1 3 + 0 0 1 4 + 0 0 1 5 + 0 0 16 + 0 0 17 + 0 0 17 + 5 0 Δ=7°38'19" R=300.00' L=39.99' 3 0 . 5 0 ' 2 5 . 5 0 ' 30.50'25.50' 28 . 0 0 ' 28 . 0 0 ' 28.00'28.00' 3 0 . 5 0 ' 2 5 . 5 0 ' 56.00' 30.50'25.50' N63° 4 5 ' 5 5 " E N76° 43' 1 2 " E S88° 41' 33"E 1 1 1 1 1 1 1 1 1 1 S88° 41' 33"ES88° 41' 33"E 415.77' 2+0 0 3+0 0 4+00 5+00 6+00 7+00 L =6 1 .3 7 'R =2 0 2 .5 0 ' Δ =1 7 °2 1 '4 8 " N45 ° 5 2 ' 3 7 " E 167 . 3 4 ' L =1 5 6 .6 0 'R =1 9 7 .5 0 ' Δ =4 5 °2 5 '4 9 " S88° 41' 33"E 221.61' 2+00 3+00 N1 ° 1 8 ' 2 7 " E 58 . 5 1 ' N1 ° 1 8 ' 2 7 " E 12 8 . 0 0 ' N6° 19' 52"W 70.74' N6° 19' 52"W 218.39' N6° 19' 52"W 218.39' Δ=57°55'53" R=227.50' L=230.02' 2+00 3+003+00 N83° 40' 08"E 184.29' N83° 40' 08"E 15.71' STA: 11+82.47 JACKSON= STA: 1+00.00 ROAD 1 STA: 14+37.61 JACKSON= STA: 7+06.91 ROAD 2 PC STA:4+85.30 PC STA:3+28.70 PC STA:1+61.37 60' INGRESS/EG R E S S A N D UTILITIES EASE M E N T A F N 3136584 STA: 1+00 BERRY VALLEY= STA: 16+06.86 JACKSON PC: 9+81.28 PC: 15+08.35 PT: 12+11.31 PT: 15+48.35 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SE E S H E E T C1 . 2 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX SEE SHEET C1.4 DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-PLAT-MAP.dwg C1.3 4 PLAT MAP (NW) 21723110300 MOSS, WILLIAM R & DEBRA A 21723130000 DDD WASHINGTON LLC 21723120400 HUDDLESTON, JOE D INGRESS/EGRESS EASEMENT (TO BE VACATED) WETLAND BUFFER EDGE OF WETLAND BUILDING SETBACK (TYP.) 10' UTILITY EASEMENT (TYP.) 5 0 . 0 0 ' 56 . 0 0 ' 56.00' 5 6 . 0 0 ' R5 0 . 0 0 ' R 2 5 . 0 0 ' ( T Y P . ) 5 8 . 0 0 ' WETLAND BUFFER KEYNOTES: 2' ROOF DRAIN EASEMENT1 10/09/2024 6 0 ' JA C K S O N S T S E 5914 S.F. 5590 S.F. 6301 S.F. 28 6473 S.F. 31 5050 S.F. 25 232002 S.F. TRACT 'I' 5050 S.F. 2 5800 S.F. 42 5800 S.F. 41 5050 S.F. 24 5050 S.F. 1 4080 S.F. 21 4887 S.F. 22 1 0 1 . 0 0 ' 50.00' 1 0 1 . 0 0 ' 50.00' 50.00' 1 0 1 . 0 0 ' 44.73' 31.00' 3 9.27' 7 6 . 0 0 ' 56.00' 92 . 1 3 ' 110.2 6 ' 32.0 6 ' 87.29' 40 . 5 0 ' 121.3 9 ' 62.0 8 ' 1 2 3 . 1 4 ' 49 . 6 9 ' 40.0 0 ' 1 1 3 . 2 6 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 1 0 . 0 0 ' 40.0 0 ' 1 0 9 . 0 3 ' 3.20' 105.26'3 5 . 2 9 ' 108.3 3 ' 4 0 . 0 0 ' 102.5 7 ' 7.97' 6 . 0 3 ' 4 0 . 0 0 ' 102.9 3 ' 4 0 . 0 9 ' 32 . 5 3 ' 103.32' 2 4 . 5 8 ' 3 6 . 6 7 ' 40 . 0 0 ' 101.00'11 . 3 7 ' 2 8 . 7 5 ' 50 . 0 0 ' 101.00' 50 . 0 0 ' 101.00' 50 . 0 0 ' 101.00' 50 . 0 0 ' 3 1 . 9 6 ' 101.0 0 ' 6 9 . 2 1 ' 11 . 3 7 ' 6 . 0 3 ' 5 0 . 1 4 ' 101.0 0 ' 7 7 . 5 9 ' 101.00' 77 . 7 1 ' 101.00' 78 . 0 8 ' 101 . 0 0 ' 77 . 2 0 ' 1 0 1 . 0 0 ' 79. 1 6 ' 1 0 0 . 0 0 ' 50.0 0 ' 1 0 0 . 0 0 ' 50.0 0 ' 1 0 0 . 0 0 ' 50.0 0 ' 1 0 0 . 0 0 ' 50.0 0 ' 1 0 0 . 0 0 ' 50.0 0 ' 1 0 0 . 0 0 ' 50.0 0 ' 1 0 0 . 0 0 ' 25.8 1 ' 24.1 9 ' 1 0 0 . 0 0 ' 37. 5 9 ' 10 0 . 0 5 ' 1 0 5 . 3 1 ' 50. 0 0 ' 1 1 6 . 0 0 ' 50. 0 0 ' 1 1 6 . 0 0 ' 50. 0 0 ' 1 1 5 . 8 8 ' 81.6 8 ' 1 0 5 . 0 0 ' 1 0 3 . 4 5 ' 1 0 1 . 9 4 ' 4 0 . 0 0 ' 4 3 . 1 0 ' 4 3 . 1 0 ' 50.45' 7 8 . 9 1 ' 41.83' 1 0 4 . 0 1 ' 8.20' 1 0 8 . 9 4 ' 50.01' 1 1 4 . 6 5 ' 50.01' 1 1 9 . 8 3 ' 50.01' 1 1 4 . 2 4 ' 40. 3 1 ' 9 3 . 8 0 ' 27. 7 1 ' 6 6 . 1 8 ' 133.7 7 ' 164.6 2 ' 65 . 6 9 ' 259.03' 69 3 . 2 6 ' 55.20' 7 9 .7 4 '2 3 .6 4 ' 23. 3 2 ' 50. 0 0 ' 39. 9 8 ' 50. 0 0 ' 50. 0 0 ' 27. 3 5 ' 1 5 .1 8 '7.53' 9.34' 5 4.0 9' 39.0 7 ' 6 1 . 8 7 ' 40 . 0 0 ' 6 7 . 6 4 ' 9 5 . 9 8 ' 19.07' 5 4 . 1 7 ' 56.00'4.28' 56.00' 6214 S.F. 18 4062 S.F. 23 5000 S.F. 38 5288 S.F. TRACT 'L' 5873 S.F. 8112 S.F. 109 5805 S.F. 43 7137 S.F. 45 8288 S.F. TRACT 'H' 7387 S.F. 44 5 6 . 0 0 ' 1.00' 5522 S.F. 3 4341 S.F. 103 10.69' 48.74' 40.33' 33.13' 27.46' 4 1.2 5' 4 0 .17 ' 39.5 3 ' 40.0 0 ' 40.0 0 ' 40.0 0 ' 40.0 0 ' 40.0 0 ' 40.0 0 ' 40.0 0 ' 23.9 1 ' 115.61' 6 0 . 1 8 ' 2 3 . 3 2 ' 7 . 9 1 ' 4 .5 9 ' 111.68' 6 7.0 4' 44.7 2 ' 50.0 0 ' 50.0 0 ' 50.0 0 ' 50.0 0 ' 50.0 0 ' 48.7 2 ' 2 3 . 3 2 ' 4 9 . 6 1 ' 4 9 . 7 3 ' 50.11' 5 1.5 4 ' 53.40' 8679 S.F. 6 4611 S.F. 5 7511 S.F. 4 4400 S.F. 16 5000 S.F. 36 5000 S.F. 37 5532 S.F. 39 5288 S.F. 40 5000 S.F. 35 5000 S.F. 34 5000 S.F. 33 6437 S.F. 32 6346 S.F. 30 4400 S.F. 14 4400 S.F. 13 4400 S.F. 12 4400 S.F. 10 4400 S.F. 9 4444 S.F. 8 4400 S.F. 15 4705 S.F. 7 4395 S.F. 17 5030 S.F. 27 5792 S.F. 26 6311 S.F. 29 4216 S.F. 20 5159 S.F. 19 ROAD 1 (LOCAL ACCESS RES.) JAC K S O N S T . S E (LO C A L A C E S S R E S . ) S1 ° 1 4 ' 5 9 " W 13 2 4 . 4 4 ' S88° 50' 35"E 1326.93' S1 ° 0 9 ' 2 5 " W 12 2 . 5 3 ' S 2 2 ° 5 8 ' 4 6 " E 1 5 1 . 9 6 ' S51 ° 3 6 ' 0 1 " W 505 . 2 8 ' S6 ° 2 5 ' 4 7 " W 18 2 . 3 2 ' S83° 40' 08"W 55.20' S 6 ° 1 9 ' 5 2 " E 1 0 1 . 0 0 ' 2+ 0 0 3 + 0 0 4 + 0 0 5+ 0 0 6+0 0 7+0 0 8+0 0 9+0 0 10+ 0 0 11 + 0 0 1 2 + 0 0 1 3 + 0 0 N31° 28' 35"W 29.35' Δ=32°38'00" R=152.50' L=86.86' L = 2 3 1 . 9 9 ' R = 1 6 0 . 0 0 ' Δ = 8 3 ° 0 4 ' 3 6 " 30.50'25.50' 3 0 . 5 0 ' 2 5 . 5 0 ' 30. 5 0 ' 25. 5 0 ' 56.00' 30.50'25.50' 1 1 1 1 1 1 1 1 1 2+0 0 L =6 1 .3 7 'R =2 0 2 .5 0 ' Δ =1 7 °2 1 '4 8 " N45 ° 5 2 ' 3 7 " E 167 . 3 4 ' N6° 19' 52"W 218.39' Δ=57°55'53" R=227.50' L=230.02' 2+00 3+003+00 N83° 40' 08"E 184.29' N83° 40' 08"E 15.71' STA: 11+82.47 JACKSON= STA: 1+00.00 ROAD 1 PC STA:3+28.70 PC STA:1+61.37 60' INGRESS/EG R E S S A N D UTILITIES EASE M E N T A F N 3136584 PC: 2+89.64 PC: 4+05.85 PC: 9+81.28 PT: 3+76.50 PT: 6+37.84 PT: 12+11.31 3 5 . 0 0 ' G R A D I N G E A S E M E N T N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX SEE SHEET C1.3 DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-PLAT-MAP.dwg C1.4 5 PLAT MAP (S) 21723140102 EVANS, JEFFREY B 78640100019 TAHOMA TERRA HOLDINGS LLC 21723420000 DDD WASHINGTON LLC 21723130000 DDD WASHINGTON LLC WETLAND BUFFER EDGE OF WETLAND BUILDING SETBACK (TYP.) 5 0 . 0 0 ' 56.0 0 ' 5 6 . 0 0 ' R2 5 . 0 0 ' (T Y P . ) 10' UTILITY EASEMENT (TYP.) INGRESS/EGRESS EASEMENT (TO BE VACATED) KEYNOTES: 2' ROOF DRAIN EASEMENT1 TEMPORARY CONSTRUCTION EASEMENT PER TC REC. NO. 5028283 10/09/2024 JA C K S O N S T S E S1 ° 1 4 ' 5 9 " W 13 2 4 . 4 4 ' S88° 50' 35"E 1326.93' SEDIMENT POND (SOUTH) TOP BERM: 358 TOP OF SPILLWAY: 357.5 TOP RISER: 357 MINIMUM SURFACE AREA AT TOP OF RISER 8,300 SF 4 C2.3 SEDIMENT POND (WEST) TOP BERM: 346 TOP OF SPILLWAY: 345.5 TOP RISER: 345 MINIMUM SURFACE AREA AT TOP OF RISER 8,070 SF 4 C2.3 SEDIMENT POND (EAST) TOP BERM: 336 TOP OF SPILLWAY: 335.5 TOP RISER: 335 MINIMUM SURFACE AREA AT TOP OF RISER 7,280 SF 4 C2.3 SEDIMENT POND OUTLET IE: 341.50 58LF 12" CPEP @ 5.59% IE: 338.26 SEDIMENT POND OUTLET IE: 353.50 IE: 352.75 42LF 12" CPEP @1.79% SEDIMENT POND OUTLET IE: 331.50 IE: 330.71 33LF 12" CPEP @ 2.39% ROCK OUTFALL 6 C2.3 ROCK OUTFALL 6 C2.3 350 34 8 35 2 35 4 35 6 358 35 8 3 5 6 3 5 4 3 5 2 35 0 34 8 346 344 342 340 332 3 6 4 3 6 2 360 358 356 354 352 36 6 364 362 360 3 5 8 3 5 6 3 5 8 368 3 3 0 3 3 2 35 0 34 6 34 8 35 2 35 4 35 6 35 8 34 0 352354356 356358 346364366 340 346 346 334 334 3 4 0 3 4 6 3 4 6 3343 3 4 360356358362 35 2 35 4 3 5 6 3 5 4 37 0 36 2 36 4 36 6 36 8 38 2 386 378 382 376378 36 8 3 7 6 356 3 7 4 370 350 35 6 35 8 330 330 370 380 364 366 368 372 374 376 378 38 2 35 2 35 4 TESC AND DEMO LEGEND INLET PROTECTION CLEARING LIMITS FILTER FABRIC FENCE INTERCEPTOR DITCH CONSTRUCTION ENTRANCE RIP-RAP PROTECTION 4"x6" SPALLS REMOVE EXISTING FENCE EXISTING GRADE CONTOUR ROCK CHECK DAM EXISTING TREE TO BE REMOVED SF CL IP CE CD ID 1 C2.4 2 C2.4 6 C2.3 1 C2.3 1 C2.2 5 C2.3 RR CONDITIONS FROM HEARING EXAMINER (HE) DECISION TO BE MET PRIOR TO DEMOLITION OF EXISTING BUILDINGS HE CONDITION 1: CONDUCT ASBESTOS SURVEY BY ASBESTOS HAZARDOUS EMERGENCY RESPONSE ACT BUILDING INSPECTOR AND AN ORCAA DEMOLITION NOTIFICATION TO BE SUBMITTED. HE CONDITION 2: REMOVE ANY POTENTIALLY DANGEROUS OR HAZARDOUS MATERIALS HEARING EXAMINER CONDITIONS EXISTING TOPSOIL SHALL BE STRIPPED AND STOCKPILED ON-SITE. STOCKPILE AND COVER SOIL WITH WEED BARRIER MATERIAL THAT SHEDS MOISTURE YET ALLOWS AIR TRANSMISSION, IN APPROVED LOCATION, PRIOR TO GRADING. REPLACE STOCKPILED TOPSOIL PRIOR TO PLANTING. IF PLACED TOPSOIL PLUS COMPOST OR OTHER ORGANIC MATERIAL WILL AMOUNT TO LESS THAN 12 INCHES: SCARIFY OR TILL SUBGRADE TO DEPTH NEEDED TO ACHIEVE 12 INCHES OF LOOSENED SOIL AFTER TOPSOIL AND AMENDMENT ARE PLACED. ENTIRE SURFACE SHOULD BE DISTURBED BY SCARIFICATION. DO NOT SCARIFY WITHIN DRIP LINE OF EXISTING TREES TO BE RETAINED. WITHIN STORMWATER DRAINAGE SYSTEM LOCATIONS OR LANDSCAPED AREAS (EXCEPT BIO-RETENTION AREAS) (10 PERCENT ORGANIC CONTENT) – PLACE AND ROTOTILL 3 INCHES OF COMPOSTED MATERIAL INTO 5 INCHES OF REPLACED SOIL (A TOTAL DEPTH OF ABOUT 9.5 INCHES, FOR A SETTLED DEPTH OF 8 INCHES). SUBSOILS BELOW THIS LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES, FOR A FINISHED MINIMUM DEPTH OF 12 INCHES OF UNCOMPACTED SOIL. RAKE BEDS TO SMOOTH AND REMOVE ROCKS LARGER THAN 2 INCHES IN DIAMETER. MULCH AREAS WITH 2 INCHES OF ORGANIC MULCH OR STOCKPILED DUFF. WITHIN LAWN AREAS (5 PERCENT ORGANIC CONTENT) – PLACE AND ROTOTILL 1.75 INCHES OF COMPOSTED MATERIAL INTO 6.25 INCHES OF REPLACED SOIL (A TOTAL AMENDED DEPTH OF ABOUT 9.5 INCHES, FOR A SETTLED DEPTH OF 8 INCHES). SUBSOILS BELOW THIS LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES, FOR A FINISHED MINIMUM DEPTH OF 12 INCHES OF UNCOMPACTED SOIL. WATER OR ROLL TO COMPACT SOIL TO 85 PERCENT OF MAXIMUM. RAKE TO LEVEL, AND REMOVE SURFACE WOODY DEBRIS AND ROCKS LARGER THAN 1 INCH IN DIAMETER. POST CONSTRUCTION SOIL QUAILIITY AND DEPTH CONSTRUCTION SEQUENCE 1.ARRANGE AND ATTEND PRE-CONSTRUCTION CONFERENCE WITH THE CITY OF YELM AND CONFIRM REQUIRED INSPECTIONS. 2.STAKE CLEARING AND GRUBBING LIMITS. 3.INSTALL PERIMETER CONTROLS INCLUDING FILTER FABRIC FENCE, OFFSITE INLET PROTECTION, AND CONSTRUCTION ENTRANCE. 4.FLAG INFILTRATION AREA TO LIMIT COMPACTION AND SEDIMENT LADEN RUNOFF FROM THIS AREA. 5.INSTALL/IMPLEMENT EROSION CONTROL BMPS. 6.CONSTRUCT TEMPORARY SEDIMENT CONTROL POND PER PLAN. 7.PROVIDE SITE DEMOLITION AND ABANDON/DECOMISSION WELL AND SEPTIC TANK PER HEALTH DEPARTMENT STANDARDS. 8.CLEAR AND GRUB SITE AS NECESSARY TO INSTALL SITE IMPROVEMENTS. DURING WET SEASON, DO NOT CLEAR ANY MORE AREA THAN CAN BE STABILIZED, PER THE GRADING AND EROSION CONTROL PLAN, IN A GIVEN WORKDAY. DO NOT COMPACT INFILTRATION AREAS. 9.GRADE SITE PER GRADING PLAN. 10.INSTALL STORM SYSTEM PER PLANS. INSTALL INLET PROTECTION FOR NEW CATCH BASINS. 11.INSTALL FORCE MAIN AND STEP SYSTEM TANKS. 12.INSTALL WATER MAIN AND FIRE SUPPRESSION LINES. 13.CONSTRUCT DRIVE AREAS. 14.INSTALL BIORETENTION SOILS AND PLANTINGS. DO NOT PLACE INFILTRATION FACILITIES ON LINE UNTIL THE SITE IS FULLY STABILIZED. 15.STABILIZE UNPAVED AREAS OF THE SITE BY HYDRO-SEEDING OR OTHER APPROPRIATE METHODS PER THE EROSION CONTROL NOTES. 16.ONCE THE SITE HAS BEEN FULLY STABILIZED PLACE INFILTRATION FACILITIES ONLINE. 17.PAVE ONSITE DRIVE AREAS. 18.REMOVE ALL TEMPORARY EROSION CONTROL FACILITIES AFTER SITE HAS BEEN PERMANENTLY STABILIZED AND APPROVED BY THE CITY. 19.CLEAN STORM DRAINAGE SYSTEM PIPING AND CATCH BASINS. 20.CALL FOR FINAL INSPECTION(S). N GRAPHIC SCALE 0 80 160 FEET 1" = 80 FEET 40 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-TESC-DEMO.dwg C2.1 6 TESC AND DEMOLITION PLAN MA T C H L I N E S E E S H E E T C2 . 2 KEYNOTES DECOMMISSION SEPTIC SYSTEM DECOMMISSION WELL DEMOLISH EXISTING STRUCTURES REMOVE EXISTING BARB WIRE FENCING PRESERVE/PROTECT EXISTING CYPRESS TREES 1 2 3 4 5 1 2 33 3 5 4TYP CD (TYP.)SF (TYP.)CL (TYP.) IP(TYP.) CD (TYP.) IP(TYP.) ID (TYP.) ID (TYP.) RR TEMPORARY CONSTRUCTION EASEMENT PER TC REC. NO. 5028283 10/09/2024 BERRY VALLEY RD SE 3 3 0 330 330 330 33 0 3 2 6 3 2 8 328 328 5 TESC AND DEMO LEGEND INLET PROTECTION CLEARING LIMITS FILTER FABRIC FENCE INTERCEPTOR DITCH CONSTRUCTION ENTRANCE RIP-RAP PROTECTION 4"x6" SPALLS REMOVE EXISTING FENCE EXISTING GRADE CONTOUR ROCK CHECK DAM EXISTING TREE TO BE REMOVED SF CL IP CE CD ID 1 C2.4 2 C2.4 6 C2.3 1 C2.3 1 C2.2 5 C2.3 RR BERRY VALLEY RD SE 100.00' N GRAPHIC SCALE 0 20 40 FEET 1" = 20 FEET 10 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-TESC-DEMO.dwg C2.2 7 TESC AND DEMOLITION PLAN MA T C H L I N E S E E S H E E T C2 . 1 MA T C H L I N E A A MA T C H L I N E A A SE E O F F S I T E I M P R O V E M E N T S P E R M I T # NOTES: 1.FILTERS SHALL BE i NSPECTED AFTER EACH STORM EVENT AND CLEANED OR REPLACED WHEN 1/3 FULL. 2.INSTALL INLET PROTECTION IN ALL NEW STORM STRUCTURES THAT WILL COLLECT STORMWATER AS THEY ARE INSTALLED. ADAPTOR SKIRT RETRIEVAL STRAP OVERFLOW (TO BYPASS PEAK STORM VOLUMES) EXISTING CATCH BASIN SEDIMENT ACCUMULATION GEOTEXTILE FABRIC 24 " 36"48" 1 NOT TO SCALE INLET PROTECTION KEYNOTES REMOVE EXISTING ASPHALT ROAD WITHIN EXISTING AND PROPOSED ROW. MAINTAIN ACCESS TO LOCAL RESIDENTS. REMOVE EXISTING 24" CONCRETE CREEK CULVERTS (2). REMOVE EXISTING BARB WIRE FENCING PROVIDE TEMPORARY IMPERMEABLE BARRIER TO FACILITATE CULVERT CONSTRUCTION COORDINATE WITH PURVEYOR FOR RELOCATION OF COMMUNICATION LINES WITH ROAD AND CULVERT REPLACEMENT. INSTALL TEMPORARY 12" DIA. GRAVITY BYPASS LINE FOR CREEK 1 2 3 4 5 6 1 1 1 2 CL SF TYP TYP 3 TYP 3TYP CE IP TYP TEMPORARY BYPASS INLET TEMPORARY BYPASS OUTLET 4 4 6 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-TESC-DEMO.dwg C2.3 8 TESC NOTES AND DETAILS CHECK DAM 20 5 10 10 6 15 5 20 4 25 2 50 100 % 1 SPACING (FT.) DITCH SLOPE CHECK DAM SPACING A AND B ARE OF EQUAL ELEVATION L = THE DISTANCE SUCH THAT POINTS 2:1 SLOPES 3: 1 L A TOP OF DITCH B 3:1 2"-4" ROCK 24" MIN. BOTTOM AND SIDES OF THE DITCH ROCK MUST COMPLETELY COVER THE 6" MIN. 4"-8" QUARRY SPALLS GEOTEXTILE 12" MIN. THICKNESS EXIST I N G R O A D R = 25' MIN. INGRESS/EGRESS AREA PROVIDE FULL WIDTH OF 20' M I N . RUNOFF DRAINS OFF THE PAD ENTRANCE BE CROWNED SO THAT IT IS RECOMMENDED THAT THE 1 0 0 ' 1.QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 2.IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON-SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, THE CONSTRUCTION OF A SMALL SUMP SHALL BE CONSIDERED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP. 4.ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 5.IF VEHICLES ARE ENTERING OR EXITING THE SITE AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. MAINTENANCE STANDARDS PROVIDE DIP CULVERT FOR TEMPORARY CONTROL OF DRAINAGE. 1' M I N . INLET/OUTFALL PIPE OUTFALL P I P E SECTION VIEW PLAN VIEW EXISTING AND/OR PROPOSED GROUND 12" MIN. DEPTH (12"Ø PIPE) 18" MIN. DEPTH (15"-18"Ø PIPE) 24" MIN. ( 24"-36"Ø PIPE) 4" MIN. FACE QUARRY ROCK DIA. +4" OVERFLOW SPILLWAY 6' MINIMUM WIDTH 0.5' FREEBOARD 1' OF 3 4" -3" WASHED ROCK 1' OF QUARRY SPALLS SPILLWAY ELEV PER PLANS TOP OF BERM: PER PLANS 3 NOT TO SCALE SEDIMENT POND RISER1NOT TO SCALE GRAVEL CHECK DAM 2 NOT TO SCALE EMERGENCY OVERFLOW SPILLWAY 4 NOT TO SCALE TEMPORARY SEDIMENT POND 5 NOT TO SCALE CONSTRUCTION ENTRANCE 6 NOT TO SCALE ROCK OUTFALL 12" CPEP BERM ELEVATION: PER PLAN MAX WATER SURFACE ELEVATION: PER PLAN1' FREEBOARD 1' MIN. 2 : 1 M A X . 3H : 1 V M A X . 3 H : 1 V M A X . NOTES: 1. A STAFF GAUGE SHALL BE PLACE IN THE POND WITH 1 FOOT MEASUREMENTS SHOWN TO A HEIGHT OF 5 FEET ABOVE POND BOTTOM TO MONITOR SEDIMENT LEVELS. WIRE BACKED SILT FENCE "KEYED" INTO SLOPE TO PREVENT FLOW AROUND. PER PLANS OUTLET ELEVATION PER PLAN BOTTOM ELEVATION: PER PLAN 1. 0 0 ' SE D I M E N T ST O R A G E 3. 5 0 ' SE T T L I N G D E P T H 6.0' MIN. 10" MIN POLYETHYLENE CAP PERFORATED POLYETHYLENE DRAINAGE TUBING, DIAMETER MIN. 2" LARGER THAN DEWATERING ORIFICE. TUBING SHALL COMPLY WITH ASTM F667 AND AASHTO M294 PROVIDE ADEQUATE STRAPPING WATERPROOF COUPLING DEWATERING ORIFICE, SCHEDULE 40 STEEL STUB MIN 2.50" DIAMETER ORIFICE ALTERNATIVELY, METAL STAKES AND WIRE MAY BE USED TO PREVENT FLOTATION TACK WELD CONCRETE BASE CORRUGATED METAL RISER TEMPORARY SEDIMENT POND BOTTOM 6" M I N 18 " M I N 2x RISER DIAMETER (MIN) 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-TESC-DEMO.dwg C2.4 9 TESC NOTES AND DETAILS CONSTRUCTION NOTES 5. 4. 3. 2.UTILITIES INSPECTOR PRIOR TO CONSTRUCTION. SHALL SECURE THE NECESSARY PERMITS FROM THE YELM CONSTRUCTED IN THE YELM RIGHT-OF-WAY, THE APPLICANT IF WATER OR OTHER UTILITIES ARE REQUIRED TO BE BE IN ATTENDANCE. THE DEVELOPER AND HIS/HER CONTRACTOR(S) MUST YELM'S DEVELOPMENT AND UTILITIES INSPECTOR. PRECONSTRUCTION CONFERENCE SHALL BE SCHEDULED WITH OR IMPROVEMENTS TO EXISTING ROADWAY FACILITIES, A PRIOR TO ANY ON SITE IMPROVEMENTS, ROADWAY CONSTRUCTION, CONSTRUCTED FACILITIES OR ADJACENT PROPERTIES. UNDERTAKEN DURING CONSTRUCTION TO AVOID DAMAGE TO TEMPORARY EROSION AND SEDIMENTATION CONTROL SHALL BE IS RESPONSIBLE FOR SCHEDULING THIS WORK. QUALIFIED LICENSED SURVEYOR. THE DEVELOPER OR CONTRACTOR CONSTRUCTION STAKING SHALL BE BY THE DESIGN ENGINEER OR A CONSTRUCTION USE BY THE ENGINEER. RESPECTS, INCLUDING SAND EQUIVALENT, WILL BE APPROVED FOR NATIVE MATERIALS MEETING THE SPECIFICATIONS IN ALL ASSOCIATION, AND CITY OF YELM PUBLIC WORKS STANDARDS. AND WASHINGTON STATE CHAPTER, AMERICAN PUBLIC WORKS JOINTLY BY WASHINGTON STATE DEPARTMENT OF TRANSPORTATION FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, PUBLISHED MOST CURRENT STANDARD SPECIFICATIONS FOR ROAD SPECIFICATIONS WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE1. A SILT SOCK SHALL BE INSTALLED AT EACH CATCH BASIN LOCATION.6. SEDIMENTS OR BUILD A NEW FENCE PARALLEL TO THE OLD ONE. WHEN SEDIMENT BUILDUP BECOMES EXCESSIVE, REMOVE THE AND DAILY DURING PROLONGED RAIN AND REPAIR THEM AS NECESSARY. POSSIBLE. INSPECT FILTER FABRIC FENCES AFTER EACH RUNOFF EVENT STORM WATER DISCHARGED OFF SITE IS AS FREE OF SEDIMENT AS 9. FILTER FABRIC FENCES SHALL BE MAINTAINED IN ORDER THAT DURING CONSTRUCTION AND SHALL WATER DOWN AREAS AS NECESSARY 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL ON SITE AND IN CONFORMANCE WITH THE PERTINENT CITY OF YELM ORDINANCES. STABILIZED BY SEEDING AND MULCHING. UNWORKED REGULARLY OR FOR AN EXTENDED TIME SHALL BE DISTURBED AREAS GREATER THAN 5,000 S.F. THAT ARE LEFT 5. DURING THE TIME PERIOD OF NOVEMBER 1 THROUGH APRIL 30, ALL 6. STOCKPILED DIRT MATERIAL SHALL BE COVERED. BY THE CITY. THROUGHOUT DURATION OF PROJECT CONSTRUCTION AS DIRECTED 4. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES ROCK ACCESS DRIVEWAY SHALL BE IN PLACE, AS SHOWN ON PLAN. 3. PRIOR TO ANY OTHER WORK ON SITE, EROSION CONTROL FENCING AND CITY OF YELM OR OTHER GOVERNING AUTHORITY OR AGENCY. 2. COMPLY WITH ALL OTHER PERMITS AND OTHER REQUIREMENTS BY FOLLOWING COMPLETION OF CONSTRUCTION. SHALL BE CLEANED OF ALL SILTS, SAND AND OTHER MATERIALS WATER POLLUTION/FLOOD ACTIVITIES AND CONVEYANCE SYSTEMS USED AS PART OF THE TEMPORARY EROSION CONTROL AND B. ALL PERMANENT STORAGE AND DETENTION AREAS MANUAL. REQUIREMENTS OF TABLE 9.1 OF THE THURSTON REGION DRAINAGE 8. ALL DISTURBED AREAS SHALL BE SEEDED PER THE STABILIZATION PRECLUDE ANY CONSTRUCTION ACTIVITY ON THE SITE. SUBMITTAL AND APPROVAL OF THESE PLANS SHALL SHALL BE SUBMITTED TO AND APPROVED BY THE COUNTY. A. SOIL EROSION AND WATER POLLUTION/FLOOD CONTROL PLANS SPECIFICATIONS AND AS FOLLOWS: REQUIRED IN ACCORDANCE WITH SECTION 1-07.15 OF THE STANDARD 1. TEMPORARY EROSION/WATER POLLUTION MEASURES SHALL BE DRAINAGE, GRADING AND OTHER TREATMENT. CONTRACTOR, BUT MUST BE AUGMENTED WITH MULCH, NETTING, OR HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE APPLICANT/ APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED, SEEDING ALONE WILL BE ACCEPTABLE ONLY DURING THE MONTHS OF TREATMENT APPLICABLE TO THE TIME OF YEAR IN QUESTION. GRASS MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH NO FURTHER WORK IS ANTICIPATED FOR A PERIOD OF 30 DAYS OR 16. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE AND/OR STORM DRAINAGE SYSTEMS. ADJACENT PROPERTIES, SENSITIVE AREAS, NATURAL WATER COURSES SHALL INSTALL ADDITIONAL FACILITIES AS NECESSARY TO PROTECT CONTROL EROSION AND SEDIMENTATION, THE APPLICANT/CONTRACTOR MEASURES AS SHOWN ON THIS DRAWING NOT PROVE ADEQUATE TO 15. SHOULD THE TEMPORARY EROSION AND SEDIMENTATION CONTROL SATISFIED. CONTINUE UNTIL SUCH TIME AS THE AFFECTED PROPERTY OWNER IS COMMENCE RESTORATION METHODS. RESTORATION ACTIVITY WILL MUST CEASE, AND THE OWNER/CONTRACTOR WILL IMMEDIATELY DEVELOPMENT THAT WILL AGGRAVATE THE SITUATION IN THE FUTURE PROPERTY OWNERS, ALL CONSTRUCTION WORK WITHIN THE 14. IN CASE EROSION OR SEDIMENTATION OCCURS TO ADJACENT IN A FIELD BY A SOILS ENGINEER OR ENGINEERING GEOLOGIST. NATIVE SOILS. HEIGHT AND WIDTH OF THE BENCH WILL BE DETERMINED (HORIZONTAL TO VERTICAL) SHALL BE BENCHED AS DIRECTED INTO 13. PLACEMENT OF FILL SECTIONS ON SLOPES GREATER THAN 4:1 BACKFILL SHALL BE COMPACTED AS SPECIFIED ABOVE. DENSITY BEFORE PLACING THE NEXT LIFT. ALL UTILITY TRENCH MOISTURE CONTENT, AND COMPACTED TO THE SPECIFIED MINIMUM EIGHT INCHES LOOSE THICKNESS, CONDITIONED TO THE OPTIMUM 12. ALL FILL SHALL BE PLACED IN UNIFORM HORIZONTAL LIFTS OF SIX TO CONSULTANT FOR USE. SUBSTITUTED WITH PRIOR APPROVAL BY A GEOTECHNICAL ANSI/ASTM D-1140 TEST PROCEDURE. OTHER MATERIAL MAY BE MORE THAN 7% BY WEIGHT SHALL PASS THE #200 SCREEN AS TESTED BY DETERMINED BY ANSI/ASTM TEST METHOD D-2487) SHALL BE USED. NO GRADED GRAVEL OR GRAVELY SAND (CLASSIFYING AS GW OR SW AS 11. FOR IMPORTED STRUCTURAL FILL A CLEAN, SIX-INCH MINUS, WELL CONTROL FACILITIES ONLY WHEN THE ENTIRE SITE IS STABILIZED. 17. REMOVE ALL REMAINING TEMPORARY EROSION AND SEDIMENTATION TEMPORARY EROSION CONTROL NOTES IN AREAS UNDER STRUCTURES, PAVING SECTIONS, SIDEWALKS, AND OTHER AREAS TO BE GRADED, STRIP ALL TOPSOIL AND ORGANIC MATERIAL. STOCKPILE AND COVER WITH PLASTIC ALL STOCKPILED TOPSOIL. ALL TOPSOIL AND SOD NOT TO BE REUSED SHALL BE REMOVED FROM SITE AND DISPOSED OF PROPERLY AT THE CONTRACTORS EXPENSE. FOR STRUCTURAL FILL IN AREAS UNDER FOOTINGS AND SLABS ON GRADE, ALL SOILS SHALL BE COMPACTED TO A MINIMUM DENSITY OF 90% OF ASTM D-1557 OR 95% OF UBC 70-1. THIS INCLUDES PROOF-ROLLING NATIVE SOILS EXPOSED IN THE BOTTOM OF THE EXCAVATION PRIOR TO PLACEMENT OF FILL. MATERIALS UNDER THE PAVING SECTION SHALL ALSO BE COMPACTED TO THE MINIMUM DENSITY BY PROOF-ROLLING PRIOR TO PLACEMENT OF THE PAVING SECTION; THIS INCLUDES PROOF-ROLLING IN-PLACE SOILS, SOILS THAT HAVE BEEN DISTURBED DURING CONSTRUCTION AND ALL STRUCTURAL FILL MATERIALS. 1.STOCKPILES SHALL BE STABILIZED (WITH PLASTIC COVERING OR OTHER APPROVED DEVICE) DAILY BETWEEN NOVEMBER 1 AND MARCH 31. 2.IN ANY SEASON, SEDIMENT LEACHING FROM STOCK PILES MUST BE PREVENTED. 3.TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR SEEDING. 4.PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO BE TOPSOILED SHALL BE MAINTAINED ACCORDING TO THE APPROVED PLAN. 1.MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE APPLIED AT THE RATE OF 2 TONS/ACRE. (MIN. 2" THICK) 2.MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED SLOPES GREATER THAN 2:1. 3.MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON. 4.ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1. 1.CONTRACTOR SHALL DESIGNATE A WASHINGTON STATE CERTIFIED EROSION AND SEDIMENT CONTROL LEAD WHO SHALL HAVE THE RESPONSIBILITY TO MONITOR AND IMPLEMENT EROSION CONTROL MEASURES. 2.CONTRACTOR SHALL PROVIDE AN EROSION AND SEDIMENT CONTROL LEAD (ESCL) WHO WILL BE ON-SITE OR ON CALL AT ALL TIMES. THE EROSION CONTROL LEAD SHALL HAVE THE AUTHORITY TO IMPLEMENT THE STORMWATER POLLUTION PREVENTION PLAN BASED ON SITE CONDITIONS WITHIN THEIR SCOPE. IF THE METHODS INDICATED FOR EROSION AND SEDIMENT CONTROL ARE NOT ADEQUATE, THE ESCL SHALL IMPLEMENT ADDITIONAL METHODS AS REQUIRED. 3.CONTRACTOR SHALL PREPARE A CONSTRUCTION SWPPP FOR THIS PROJECT. REFER TO THE PROJECT MANUAL FOR A SAMPLE SWPPP FOR THIS PROJECT. RETAIN A COPY OF THE SWPPP ON-SITE AT ALL TIMES AND AVAILABLE TO THE JURISDICTIONS HAVING AUTHORITY. 4.CONTRACTOR TO COORDINATE AREAS FOR LAY DOWN, STOCK PILE, TRAILERS & PARKING WITH WMD CONSTRUCTION PROJECT MANAGER BRAD OLSON. 5.CONTRACTOR TO REMOVE CONSTRUCTION DEBRIS, MUD, ROCKS, DIRT, ETC FROM EXISTING ROAD AND PARKING LOT DAILY. MULCHING NOTES TESC/SWPPP NOTES SOIL STOCKPILE NOTES 1.THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST WITH A MINIMUM SIX-INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST. 2.THE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS (WHERE FEASIBLE). THE FENCE POSTS SHALL BE SPACED A MAXIMUM OF SIX FEET APART AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 30") 3.A TRENCH SHALL BE EXCAVATED, ROUGHLY EIGHT INCHES WIDE AND TWELVE INCHES DEEP, UPSLOPE AND ADJACENT TO THE WOOD POST TO ALLOW THE FILTER FABRIC TO BE BURIED. 4.WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT LEAST ONE INCH LONG, TIE WIRES, OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF FOUR INCHES AND SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. 5.THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE, AND TWENTY INCHES OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT BE STAPLED TO EXISTING TREES. 6.WHEN EXTRA-STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE ELIMINATED. IN SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS WITH ALL OTHER PROVISIONS OF STANDARD NOTE (S) APPLYING. 7.THE TRENCH SHALL BE BACKFILL WITH 3/4 INCH MINIMUM DIAMETER WASHED GRAVEL. 8.FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. 9.FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. 10.CONTRIBUTING LENGTH TO FENCE SHALL NOT BE MORE THAN 100 FEET. 11.DO NOT INSTALL BELOW AN OUTLET PIPE OR WEIR. 12.DO NOT DRIVE OVER OR FILL OVER FILTER FABRIC FENCE. SIDE VIEW NOTES: FRONT VIEW CHAINLINK FENCE 8" 2.0' MIN. 5. 0 ' 1. 0 ' 2. 0 ' 0. 5 ' 6' MAX. 5.0' 2.0' 2.5' 2" X 4" WOOD POSTS, STANDARD OR BETTER, OR STEEL FENCE POST BURY BOTTOM OF FILTER MATERIAL IN 8"X12" TRENCH 2" X 4" BY 14 GA. WIRE FABRIC OR EQUIVALENT EXISTING GRADE ORANGE FILTER FABRIC MATERIAL 60" WIDE ROLLS - USE RINGS TO ATTACH ATTACH TO WIRE FABRIC 2" X 4" WOOD POST OR STEEL FENCE POST PROVIDE 3/4" - 1 1/2" WASHED GRAVEL BACKFILL IN TRENCH AND ON BOTH SIDES OF FILTER FENCE FABRIC ON THE SURFACE 2" X 2" BY 14 GA. WIRE FABRIC OR EQUIVALENT, AFFIX TO POST FILTER FABRIC MATERIAL MIRAFI 100 NS OR EQUIVALENT 2' MIN 1' MIN. 2 1 SPACING (FEET) 2 1 1' MIN SLOPE 1.SEED AND MULCH SHALL BE APPLIED WITHIN 5 DAYS OF DIKE CONSTRUCTION. (SEE HYDROSEEDING NOTES) 2.THE UPSLOPE SIDE OF THE DIKE SHALL PROVIDE POSITIVE DRAINAGE TO THE DIKE OUTLET. 3.NO EROSION SHALL OCCUR AT THE DIKE OUTLET. PROVIDE ENERGY DISSIPATION MEASURES AS NECESSARY. 4.SEDIMENT LADEN RUNOFF MUST BE RELEASED THROUGH A SEDIMENT TRAPPING FACILITY SUCH AS A POND, TRAP, OR SILT FENCE AS APPROPRIATE TO DRAINAGE AREA SIZE. TEMPORARY DIKE AND SWALE NOTES GRASS OR ROCK LEVEL BOTTOM SPACING=100', 200' OR 300' DEPENDING ON SLOPE (SEE TABLE) 1 NOT TO SCALE FILTER FABRIC FENCE 2 NOT TO SCALE INTERCEPTOR SWALE 10/09/2024 JA C K S O N S T S E 51 50 49 108 106 105 53 54 56 57 25 TRACT 'I' 929394 84 69 61 68 60 6766 58 65TRACT 'E'6463 70 62 2 TRACT 'G' 42 41 46 47 71 83 72 8 0 TRACT 'B' 8 2 8 1 TRACT 'A' 7 9 7 6 7 7 7 8 7 4 7 5 7 3 24 1 21 22 59 91 89 88 87 85 97 18 23 8690 38 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 TR A C T ' D ' TR A C T ' C ' 52 3 102 100 99 9596 103 98 101 14 13 12 11 10 9 8 15 7 31 28 31 18 38 6 9 29 18 38 36 37 35 34 33 11 5 4 20 19 16 17 6 13 12 11 10 9 8 7 30 27 26 39 40 32 s sss s s s s s s ssss s ss s s s s s s s s s s s s ss s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s ss ss ss ss ss s s s ss s s s s s s s s s s s s s s s s s s s s s s s s s s s s N88° 41' 33"W1323.48' S1 ° 1 4 ' 5 9 " W 13 2 4 . 4 4 ' BERRY VALLEY ROAD SE RO A D 3 ROAD 2 ROAD 1 JAC K S O N S T S E SE E S H E E T C3 . 1 SE E S H E E T C3 . 2 SEE SHEET C3.3 SEE SHEET C3.2 S1 ° 1 4 ' 5 9 " W 13 2 4 . 4 4 ' S88° 50' 35"E 1326.93' S1° 09' 25"W 122.53' S22° 58' 46"E 151.96' S51° 36' 01"W 505.28' S6° 25' 47"W 182.32' S83° 40' 08"W 55.20' S6° 19' 52"E 101.00' 350 34 8 35 2 35 4 35 6 358 35 8 3 5 6 3 5 4 3 5 2 35 0 34 8 346 344 342 340 332 3 6 4 3 6 2 360 358 356 354 352 36 6 364 362 360 3 5 8 3 5 6 3 5 8 368 3 3 0 3 3 2 36 0 35 6 35 8 36 2 34 0 352354356 362 364366 340 346 346 334 334 3 4 0 3 4 6 3 4 6 3343 3 4 360356358362 35 2 35 4 3 5 6 3 5 4 37 0 36 2 36 4 36 6 36 8 38 2 386 378 382 376 378 36 8 3 7 6 356 3 7 4 370 352 35 6 35 8 36 0 36 2 36 4 N GRAPHIC SCALE 0 80 160 FEET 1" = 80 FEET 40 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 7, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-GRAD-OVERALL.dwg C3.0 10 OVERALL GRADING PLAN TEMPORARY SLOPE GRADING EASEMENT TEMPORARY SLOPE GRADING EASEMENT RETAINING WALL DESIGNED BY OTHERS BOTTOM OF WALL (BW) TOP WALL AT PAD GRADE (TW) 1 NOT TO SCALE WALL LABELING NOMENCLATURE 10/09/2024 929394 84 69686766 656463 70 71 83 72 8 0 TRACT 'B' 8 2 8 1 TRACT 'J' TRACT 'A' 7 9 7 6 7 7 7 8 7 4 7 5 7 3 91 89 88 87 85 8690 TRACT 'K' TR A C T ' D ' TR A C T ' C ' s s s s s s ss s s s s s s s s s s s s s s s s s s s s s s s RO A D 3 3+003+00 35 6 358 35 8 3 5 6 3 5 4 3 5 2 35 0 34 8 346 344 342 340 335 332 36 6 364 362 360 3 5 8 365 367 3 3 0 3 3 1 3 3 2 34 0 355352353354356 350355 360 346365364 3 7 5 3 7 6 349 S83° 40' 08"W 55.20' 1 0 1 . 0 0 ' WETLAND BUFFER WETLAND BUFFER EDGE OF WETLAND (THOMPSON CREEK) APPROXIMATE FEMA ZONE A ELEV. 326.5 APPROXIMATE FEMA ZONE A ELEV. 326.5 BIO-INFILTRATION /INFILTRATION #2 INFILTRATION TRENCH, TYP SEE ON-LOT PLANS INFILTRATION POND #1 5.00% 3:1 3:1 2:1 6. 9 4 % 2:1 PAD 362.25 PAD 363.50 PAD 357.25 PAD 358.00 PAD 358.20 PAD 355.50 PAD 353.00 PAD 349.75 PAD 358.00PAD 358.00 PAD 357.00 PAD 357.75 PAD 356.50 PAD 354.50 PAD 351.75 PAD 348.00 PAD 346.25 P A D 3 4 4 . 5 0 P A D 3 4 2 . 2 5 P A D 3 4 0 . 2 5 P A D 3 3 7 . 0 0 P A D 3 3 6 . 0 0 P A D 3 3 5 . 0 0 P A D 3 3 6 . 2 5 P A D 3 3 9 . 7 5 PAD 364.00 P A D 3 3 8 . 0 0 PAD 365.25 PAD 363.00 P A D 3 3 7 . 5 0 PAD 356.25 TW: 342.66 BW: 346.00 TW: 347.02 TW: 349.00TW: 352.75 TW: 363.00 TW: 353.00 TW: 363.00 TW: 344.75 TW: 362.00 TW: 364.00 BW: 342.57 BW: 339.75BW: 345.65 BW: 345.65BW: 349.75 BW: 349.75 BW: 361.88 BW: 352.63 BW: 348.80 BW: 331.86 BW: 338.31 BW: 330.73 TW: 330.73 TW: 338.31 TW: 344.44 BW: 358.00 TW: 358.00TW: 365.89 BW: 352.81 TW: 349.75 6.94% BW: 347.02 BW: 341.35 BW: 337.81 BW: 341.32 BW: 332.59 BW: 331.84 BW: 331.00 TW: 337.00 TW: 338.00 TW: 339.98 TW: 357.75 TW: 354.50 TW: 351.75 2:1 BW: 339.75 TW: 344.75 TW: 330.09 BW: 326.85 TW: 329.87 BW: 326.22 BW: 354.00 TW: 364.00 BW: 359.88 TW: 361.98 BW: 358.00 TW: 362.25 370 TW: 363.00 CB#3 RIM: 357.95 CB#4 RIM: 357.32 CB#5 RIM: 356.64 CB#6 RIM: 347.28 CB#7 RIM: 347.28 CB#8 RIM: 344.19 CB#10 RIM: 340.12 CB#11 RIM: 334.47 CB#12 RIM: 334.47 CB#41 RIM: 327.58 RDCO BVR 12 RDCO BVR 13 RDCO BVR 5 RDCO BVR 6 RDCO RD3 4 RDCO RD3 3 RDCO RD3 2 RDCO RD3 1 RDCO BVR 3 RDCO RD1 3 CB#9 RIM: 340.12 CB#39 RIM: 329.21 CB#40 RIM: 329.21 RDCO BVR 25 RDCO BVR 26 RDCO BVR 24 RDCO BVR 23 RDCO BVR 20 RDCO BVR 21 RDCO BVR 22 RDCO BVR 14 RDCO BVR 15 RDCO BVR 16 RDCO BVR 17 RDCO BVR 18 RDCO BVR 19 CB#13 RIM: 335.60 RD OUTLET TO EAST POND IE: 328.00 8" (W) OUTLET TO EAST POND IE: 328.50 12" (W) BVR -P 6 RD3 -P 1 RD 3 - P 4 RD3 -P 6 RD3 -P 2 BVR -P 14 BVR -P 16BVR -P 15 BVR -P 18BVR -P 17 B V R -P 19 BVR -P 20 BVR -P 21 BVR -P 22 BVR -P 24 BVR -P 25 BVR -P 23 BVR -P 26 BVR -P 27 BVR -P 28 20 LF 12" CPEP @ 1.95% BVR -P 5 BVR -P 13 BW: 355.50 TW: 363.00 BW: 356.31 TW: 364.00 BW: 364.00 TW: 364.00 OUTLET TO WQ STRUCTURE IE: 331.20 12" (SW) OUTLET FROM WQ IE: 328.90 12" (E) BW: 332.20 TW: 346.25 BW: 355.97 TW: 360.32 BW: 358.00 TW: 358.00 TW: 358.00 BW: 355.94 ROOF RUNOFF NOTE ROOF RUNOFF SHALL BE INFILTRATED WITHIN PRIVATE SYSTEMS LOCATED ON EACH LOT FOR LOTS #66 THROUGH #87. FILL MATERIAL PLACED IN AND AROUND AREAS OF INFILTRATION TRENCHES SHALL BE FREE DRAINING FILL MATERIAL. PAD GRADE NOTES 1.ALL PAD GRADES SHOWN ARE STRUCTURAL PAD GRADES. CLEANOUT INFORMATION CLEANOUT CB#13 TYPE 1 STA: 10+28.77, 39.31' L RDCO BVR 5 CO STA: 3+59.27, 39.00' R RDCO BVR 6 CO STA: 3+98.95, 39.00' R RDCO BVR 12 CO STA: 3+49.00, 39.00' L RDCO BVR 13 CO STA: 3+91.00, 39.00' L RDCO BVR 14 CO STA: 4+78.62, 39.03' L RDCO BVR 15 CO STA: 5+28.98, 38.80' L RDCO BVR 16 CO STA: 5+79.27, 38.99' L RDCO BVR 17 CO STA: 6+30.30, 38.98' L INFORMATION RIM = 335.60 IE = 332.74 (6" NW) IE = 331.72 (8" E) RIM = 357.60 IE = 353.56 (6" E) IE = 353.56 (6" W) IE = 353.56 (6" S) RIM = 358.41 IE = 354.16 (6" W) IE = 354.16 (6" S) RIM = 357.58 IE = 353.13 (6" E) IE = 353.13 (6" W) IE = 353.13 (6" N) RIM = 358.53 IE = 354.48 (6" W) IE = 354.48 (6" N) RIM = 358.84 IE = 356.33 (6" E) RIM = 358.02 IE = 355.51 (6" W) IE = 355.51 (6" E) RIM = 356.65 IE = 351.35 (6" W) IE = 351.35 (6" E) RIM = 354.51 IE = 351.10 (6" W) IE = 351.10 (6" E) CLEANOUT INFORMATION CLEANOUT RDCO BVR 18 CO STA: 6+79.47, 39.18' L RDCO BVR 19 CO STA: 7+39.12, 39.21' L RDCO BVR 20 CO STA: 7+83.75, 39.03' L RDCO BVR 21 CO STA: 8+23.45, 38.97' L RDCO BVR 22 CO STA: 8+53.26, 38.87' L RDCO BVR 23 CO STA: 9+00.48, 38.80' L RDCO BVR 24 CO STA: 9+41.04, 38.82' L RDCO BVR 25 CO STA: 9+80.25, 39.04' L RDCO BVR 26 CO STA: 10+18.29, 39.09' L INFORMATION RIM = 351.75 IE = 349.05 (6" W) IE = 349.05 (6" E) RIM = 346.96 IE = 344.30 (6" W) IE = 344.13 (8" SW) RIM = 344.50 IE = 341.98 (6" SE) RIM = 342.27 IE = 339.76 (6" NW) IE = 339.76 (6" SE) RIM = 340.58 IE = 337.62 (6" NW) IE = 337.62 (8" SW) RIM = 338.57 IE = 336.06 (6" SE) RIM = 337.39 IE = 334.40 (6" NW) IE = 334.40 (6" SE) RIM = 336.46 IE = 333.94 (6" NW) IE = 333.94 (6" SE) RIM = 335.62 IE = 332.79 (6" NW) IE = 332.79 (6" SE) CLEANOUT INFORMATION CLEANOUT RDCO RD3 1 CO STA: 0+53.07, 36.47' L RDCO RD3 2 CO STA: 1+02.47, 58.45' L RDCO RD3 3 CO STA: 1+43.16, 40.61' L RDCO RD3 4 CO STA: 2+29.72, 38.52' L INFORMATION RIM = 366.20 IE = 361.45 (6" NW) IE = 361.45 (6" W) RIM = 363.97 IE = 359.77 (6" S) IE = 359.77 (6" N) IE = 359.77 (6" W) RIM = 362.32 IE = 356.59 (6" SW) IE = 356.59 (6" NE) IE = 356.59 (6" W) RIM = 358.25 IE = 354.66 (6" SE) IE = 354.66 (8" NE) IE = 354.66 (6" SW) PIPE TABLE NAME BVR -P 5 BVR -P 6 BVR -P 13 BVR -P 14 BVR -P 15 BVR -P 16 SIZE 6" 6" 6" 6" 6" 6" LENGTH 40' 40' 40' 42' 50' 50' SLOPE 2.50% 1.50% 5.00% 3.21% 1.63% 8.26% MATERIAL PVC PVC PVC PVC PVC PVC PIPE TABLE NAME BVR -P 17 BVR -P 18 BVR -P 19 BVR -P 20 BVR -P 21 BVR -P 22 SIZE 6" 6" 6" 8" 6" 6" LENGTH 51' 49' 68' 25' 50' 33' SLOPE 0.50% 4.16% 7.03% 0.50% 4.45% 6.45% MATERIAL PVC PVC PVC PVC PVC PIPE TABLE NAME BVR -P 23 BVR -P 24 BVR -P 25 BVR -P 26 BVR -P 27 BVR -P 28 SIZE 8" 6" 6" 6" 6" 8" LENGTH 24' 41' 39' 38' 10' 42' SLOPE 0.55% 4.08% 1.17% 3.02% 0.50% 8.82% MATERIAL PVC PVC PVC PVC PIPE TABLE NAME RD3 -P 1 RD3 -P 2 RD3 -P 4 RD3 -P 6 SIZE 6" 6" 6" 8" LENGTH 56' 45' 69' 27' SLOPE 3.00% 7.00% 2.20% 1.00% MATERIAL PVC PVC PVC88' PVC BVR -P 28 PVC PVC PVC SITE WALL NOTES 1.SEE DETAIL 1 SHEET C3.0 FOR WALL LABELING NOMENCLATURE. N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SE E S H E E T C3 . 2 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-GRAD-STRM.dwg C3.1 11 GRADING AND ROOF DRAINAGE PLAN (NE) BERRY VALLEY ROAD SE 1 C5.8 2 C5.8 2 C5.8 REPAVED DRIVEWAY TO PARCEL 21724230200 WITHIN EXISTING ROW. COORDINATE WITH PROPERTY OWNER REPAVED DRIVEWAY TO PARCEL 21724230900 WITHIN EXISTING ROW. COORDINATE WITH PROPERTY OWNER PAVE DRIVEWAY FOR PARCEL 21724230105. COORDINATE WITH PROPERTY OWNER OFFSITE ROAD IMPROVEMENTS FOR BERRY VALLEY ROAD ARE UNDER SEPARATE PLAN SET 10/09/2024 51 50 49 108 106 105 53 54 56 57 94 6160 58 TRACT 'E' 646362 2 TRACT 'G' 42 41 46 47 1 59 97 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 52 3 102 100 99 9596 103 98 101 4 40 s sss s s s s s s ssss s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s TW: 365.27 2+00 3+003+00 PAD 355.75 TW: 363.77 BW: 363.77 TW: 365.25 BW: 365.25 BW: 362.50 TW: 367.77 BW: 361.50 350 34 8 35 2 35 4 35 6 3 6 4 3 6 2 358 356 354 352 3 5 6 3 5 8 351 339 346 346 335334 335334 3 3 9 3 4 6 3 4 6 333334 3 3 4 341 360359 35 2 35 1 357 35 3 3 5 7 3 5 1 36 7 36 8 3 7 5 3 7 6 36 0 36 5 36 5 35 8 35 8 35 8 35 9 36 1 36 2 36 3 36 4 S6 ° 2 5 ' 4 7 " W S83° 40' 08"W 55.20' S 6 ° 1 9 ' 5 2 " E 1 0 1 . 0 0 ' TYPICAL DISPERSION TRENCH (TYP.) 50:1 14:1 7 : 1 2:1 50:1 2: 1 50 : 1 2 : 1 Horizontal 3 : 1 3:1 2:1 2:1 3:1 9:1 2:1 2 : 1 PAD 357.00 PAD 354.25 PAD 352.00 PAD 350.25 PAD 349.50 PAD 353.50 PAD 356.75 PAD 352.75 PAD 354.75 PAD 359.50 PAD 360.50 PAD 362.50 PAD 360.50 PAD 358.00PAD 357.00 PAD 356.00 PAD 355.00PAD 354.00 PAD 352.50 PAD 351 . 2 2 PAD 351 . 7 5 PAD 352 . 2 5 PAD 352. 7 5 PAD 353.2 5 PAD 354.00 PAD 355.00 PAD 356.00 PAD 357.00 PAD 357.75 PAD 350.25 PAD 347.50 PAD 346.25 PAD 367.77PAD 365.27 PAD 363.77 PAD 363.15 PAD PAD 351 . 7 5 PAD 351 . 2 5 PAD 350 . 7 5 PAD 350 . 2 5 PAD 350 . 6 0 PAD 361.50 PAD 356.25 BW: 358.00 TW: 365.89TW: 342.58 BW: 342.58 TW: 341.38 BW: 341.38 TW: 360.03 BW: 355.75 TW: 360.50 BW: 356.25BW: 357.50 TW: 360.50 TW: 352.75 BW: 352.75 BW: 356.75 TW: 356.75 BW: 348.93 TW: 348.93 BW: 348.90 TW: 349.93 TW: 341.42 BW: 338.58 TW: 341.45 BW: 338.48 BVR -P 12 BVR -P 4 BVR -P 5 BVR -P 13 360 BW: 358.00 TW: 362.25 355 TW: 354.37 BW: 354.37 TW: 358.00 TW: 363.50 TW: 363.50 BW: 358.00 BW: 358.00 BW: 363.71 TW: 350.25 BW: 341.25 TW: 350.25 BW: 340.30 TW: 350.29 BW: 350.27 TW: 351.75 BW: 341.75 TW: 352.25 BW: 342.25 TW: 352.75 BW: 342.74 TW: 353.25 BW: 343.25 TW: 354.00 BW: 344.00 TW: 354.00 BW: 346.01 TW: 353.69 BW: 353.19 TW: 357.00 BW: 346.60 BW: 363.00 TW: 363.00 CB#27 RIM: 358.97 CB#21 RIM: 363.51 CB#20 RIM: 363.65 CB#22 RIM: 364.46 CB#23 RIM: 364.13 CB#24 RIM: 364.13 CB#25 RIM: 359.94 CB#26 RIM: 358.68 CNTRL#2 RIM: 358.84 CB#37 RIM: 354.97 CB#38 RIM: 354.89 CB#36 RIM: 353.51 CB#28 RIM: 352.39 CB#35 RIM: 351.45 CB#34 RIM: 351.45 CB#32 RIM: 350.45 CB#33 RIM: 350.43 CB#1 RIM: 349.84 CB#2 RIM: 349.84 CB#31 CNTRL#1 CB#30 RIM: 345.94 CB#29 RIM: 345.94 WEST POND DISPERSAL BASIN IE: 335.80 18" (SE) OUTLET FROM WEST POND IE: 335.50 18" (W)OUTLET TO WEST POND IE: 336.00 12" (SE) OUTLET FROM SOUTH POND IE: 351.50 18" (SW) OUTLET TO SOUTH POND IE: 353.00 12" (E) OUTLET SOUTH POND IE: 352.75 18" (N) RDCO BVR 12 RDCO RD2 16RDCO RD2 15 RDCO RD2 14RDCO RD2 13 RDCO RD2 12 RDCO RD2 5 RDCO RD2 4 RDCO RD2 3 RDCO RD2 2 RDCO RD2 1 RDCO RD2 6 RDCO RD2 7 RDCO RD2 8 RDCO RD2 9 RDCO RD2 10 RDCO RD2 11 RDCO RD2 17 RDCO RD2 18 RDCO RD2 19 RDCO RD2 20 RDCO RD2 21 RDCO JX 36 RDCO JX 37 RDCO JX 38 RDCO JX 39 RDCO JX 40 RDCO JX 41 RDCO BVR 1 RDCO BVR 2 RDCO BVR 3 RDCO BVR 4 RDCO BVR 11 RDCO BVR 10 RDCO BVR 9 RDCO BVR 8 RDCO BVR 7 RDCO JX 42 RDCO JX 43 RDCO JX 44 RDCO JX 45 RDCO RD1 3 RDCO RD1 2 RDCO RD1 1 RDCO JX 34 RDCO JX 33 RDCO JX 32 JX -P 34 JX -P 37 JX -P 47 JX -P 48 JX -P 45 JX -P 42 JX -P 40 JX -P 39 JX -P 41 JX -P 38 JX -P 35 JX -P 36 RD1 -P 4 RD1 -P 1 BVR -P 1 RD2 -P 4 RD2 -P 24 RD2 -P 21 RD2 -P 19RD2 -P 13 RD2 -P 12 RD2 -P 7 RD2 -P 18RD2 -P 15 RD2 -P 14 RD2 - P 1 1 RD2 -P 8 RD2 -P 5 RD2 -P 6 RD2 -P 9 RD2 - P 1 0 RD2 -P 16 RD2 -P 17 RD2 -P 20 RD2 -P 23 RD1 -P 3 BVR -P 8 BVR -P 9 BVR -P 10 BVR -P 11 BVR -P 3 JX - P 4 6 BVR -P 14 BVR -P 2 JX -P 43 RD2 -P 1 BVR -P 13 JX -P 44 BW: 355.97 TW: 360.32 PAD GRADE NOTES 1.ALL PAD GRADES SHOWN ARE STRUCTURAL PAD GRADES. SITE WALL NOTES 1.SEE DETAIL 1 SHEET C3.0 FOR WALL LABELING NOMENCLATURE. CLEANOUT INFORMATION CLEANOUT RDCO BVR 1 CO STA: 1+53.00, 39.00' R RDCO BVR 2 CO STA: 2+38.77, 39.00' R RDCO BVR 3 CO STA: 2+79.27, 39.00' R RDCO BVR 4 CO STA: 3+19.27, 39.00' R RDCO BVR 7 CO STA: 1+53.57, 39.00' L RDCO BVR 8 CO STA: 1+89.32, 39.00' L RDCO BVR 9 CO STA: 2+29.00, 39.00' L RDCO BVR 10 CO STA: 2+69.00, 39.00' L RDCO BVR 11 CO STA: 3+09.32, 39.00' L RDCO JX 36 CO STA: 13+48.62, 36.50' R RDCO JX 37 CO STA: 13+80.67, 36.50' R RDCO JX 38 CO STA: 14+17.67, 36.50' R RDCO JX 39 CO STA: 14+60.96, 36.50' R RDCO JX 40 CO STA: 15+04.57, 37.31' R RDCO JX 41 CO STA: 15+20.81, 38.27' R RDCO JX 42 CO STA: 16+29.86, 39.00' L RDCO JX 43 CO STA: 16+40.05, 39.00' L RDCO JX 44 CO STA: 16+79.84, 39.00' L RDCO JX 45 CO STA: 17+19.79, 39.00' L INFORMATION RIM = 351.22 IE = 347.42 (6" SW) IE = 347.42 (8" N) IE = 347.42 (6" E) RIM = 352.75 IE = 349.14 (6" E) IE = 349.14 (6" W) IE = 349.14 (6" S) RIM = 354.75 IE = 351.16 (6" E) IE = 351.16 (6" W) IE = 351.16 (6" S) RIM = 356.28 IE = 352.56 (6" E) IE = 352.56 (6" W) IE = 352.56 (6" S) RIM = 350.16 IE = 346.10 (6" E) IE = 346.10 (8" S) IE = 345.98 (6" N) RIM = 350.82 IE = 346.64 (6" E) IE = 346.64 (6" W) IE = 346.34 (6" N) RIM = 352.39 IE = 347.53 (6" E) IE = 347.53 (6" W) IE = 347.53 (6" N) RIM = 354.44 IE = 349.13 (6" E) IE = 349.13 (6" W) IE = 349.13 (6" N) RIM = 356.22 IE = 351.15 (6" E) IE = 351.15 (6" W) IE = 351.15 (6" N) RIM = 361.96 IE = 358.01 (6" N) IE = 358.01 (6" E) RIM = 361.35 IE = 357.37 (6" S) IE = 357.37 (6" N) IE = 357.37 (6" E) RIM = 360.50 IE = 356.81 (6" S) IE = 356.81 (6" N) IE = 356.81 (6" E) RIM = 359.50 IE = 356.16 (6" S) IE = 356.16 (8" W) IE = 356.38 (6" E) RIM = 356.75 IE = 353.23 (6" E) IE = 353.23 (6" N) RIM = 355.67 IE = 350.89 (6" S) IE = 350.89 (6" N) IE = 350.89 (6" E) RIM = 350.25 IE = 346.75 (6" N) IE = 346.75 (6" W) RIM = 349.23 IE = 344.98 (6" S) IE = 344.98 (6" N) RIM = 347.50 IE = 344.00 (6" S) IE = 344.00 (6" N) IE = 344.00 (6" W) RIM = 346.25 IE = 343.00 (6" S) IE = 343.00 (8" E) IE = 343.00 (6" W) CLEANOUT INFORMATION CLEANOUT RDCO RD2 1 CO STA: 1+35.82, 44.20' R RDCO RD2 2 CO STA: 1+61.37, 36.50' R RDCO RD2 3 CO STA: 1+94.05, 36.50' R RDCO RD2 4 CO STA: 2+44.68, 36.50' R RDCO RD2 5 CO STA: 2+95.72, 36.50' R RDCO RD2 6 CO STA: 1+62.08, 41.51' L RDCO RD2 7 CO STA: 1+90.92, 41.51' L RDCO RD2 8 CO STA: 2+40.46, 41.50' L RDCO RD2 9 CO STA: 2+93.16, 41.50' L RDCO RD2 10 CO STA: 3+66.05, 41.50' L RDCO RD2 11 CO STA: 3+84.39, 41.50' L RDCO RD2 12 CO STA: 4+56.52, 36.50' R RDCO RD2 13 CO STA: 4+85.30, 36.50' R RDCO RD2 14 CO STA: 5+29.19, 36.56' R RDCO RD2 15 CO STA: 5+79.50, 36.63' R RDCO RD2 16 CO STA: 6+29.83, 36.70' R RDCO RD2 17 CO STA: 4+56.52, 41.50' L RDCO RD2 18 CO STA: 4+66.32, 41.50' L RDCO RD2 19 CO STA: 5+11.74, 41.50' L INFORMATION RIM = 350.69 IE = 347.17 (6" N) IE = 347.17 (6" SE) RIM = 351.39 IE = 346.51 (6" SW) IE = 348.65 (8" NW) IE = 348.65 (6" NE) IE = 346.51 (6" SE) RIM = 351.69 IE = 349.47 (6" NE) IE = 349.47 (6" SW) IE = 347.33 (6" SE) RIM = 352.20 IE = 349.98 (6" NE) IE = 349.98 (6" SW) IE = 347.84 (6" SE) RIM = 352.67 IE = 351.00 (6" SW) IE = 348.86 (6" SE) RIM = 352.00 IE = 346.37 (6" NE) IE = 346.37 (8" SE) IE = 346.37 (6" NW) RIM = 351.77 IE = 347.24 (6" NE) IE = 347.24 (6" SW) IE = 347.24 (6" NW) RIM = 352.26 IE = 347.74 (6" NE) IE = 347.74 (6" SW) IE = 347.74 (6" NW) RIM = 352.80 IE = 348.27 (6" SW) IE = 348.27 (6" NW) RIM = 353.52 IE = 348.29 (6" NE) IE = 348.29 (8" SE) IE = 348.29 (6" NW) RIM = 353.69 IE = 349.40 (6" SW) IE = 349.40 (6" NW) RIM = 354.92 IE = 350.49 (6" E) IE = 350.49 (8" N) IE = 350.49 (6" S) RIM = 355.44 IE = 351.66 (6" E) IE = 351.66 (6" W) IE = 351.66 (6" S) RIM = 356.26 IE = 352.54 (6" E) IE = 352.54 (6" W) IE = 352.54 (6" S) RIM = 357.23 IE = 353.55 (6" E) IE = 353.55 (6" W) IE = 353.55 (6" S) RIM = 358.19 IE = 354.56 (6" S) IE = 354.56 (6" W) RIM = 355.02 IE = 350.81 (6" E) IE = 350.81 (8" S) IE = 350.81 (6" N) RIM = 355.10 IE = 351.99 (6" E) IE = 351.99 (6" W) IE = 351.99 (6" N) RIM = 356.02 IE = 352.48 (6" E) IE = 352.48 (6" W) IE = 352.48 (6" N) PIPE TABLE NAME BVR -P 1 BVR -P 2 BVR -P 3 BVR -P 4 BVR -P 5 BVR -P 8 BVR -P 9 BVR -P 10 BVR -P 11 BVR -P 12 BVR -P 13 JX -P 38 JX -P 39 SIZE 8" 6" 6" 6" 6" 8" 6" 6" 6" 6" 6" 6" 6" LENGTH 24' 86' 40' 40' 40' 24' 36' 40' 40' 40' 40' 32' 37' SLOPE 7.60% 2.00% 5.00% 3.50% 2.50% 1.50% 1.50% 2.25% 4.00% 5.00% 5.00% 2.00% 1.50% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PIPE TABLE NAME JX -P 40 JX -P 41 JX -P 42 JX -P 43 JX -P 44 JX -P 45 JX -P 46 JX -P 47 JX -P 48 SIZE 6" 8" 6" 6" 6" 6" 6" 6" 8" LENGTH 43' 18' 15' 30' 20' 10' 40' 40' 24' SLOPE 1.50% 8.77% 15.92% 7.02% 7.02% 17.36% 2.47% 2.50% 1.00% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PIPE TABLE NAME RD2 -P 1 RD2 -P 4 RD2 -P 5 RD2 -P 6 RD2 -P 7 RD2 -P 8 RD2 -P 9 RD2 -P 10 RD2 -P 11 RD2 -P 12 RD2 -P 13 RD2 -P 14 RD2 -P 15 SIZE 6" 8" 6" 6" 6" 8" 6" 6" 6" 8" 6" 8" 6" LENGTH 7' 19' 33' 51' 51' 24' 29' 50' 53' 24' 22' 18' 23' SLOPE 2.00% 2.00% 2.50% 1.00% 2.00% 1.00% 3.00% 1.00% 1.00% 13.55% 5.00% 12.26% 5.00% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PIPE TABLE NAME RD2 -P 16 RD2 -P 17 RD2 -P 18 RD2 -P 19 RD2 -P 20 RD2 -P 21 RD2 -P 23 RD2 -P 24 SIZE 6" 6" 6" 8" 6" 6" 6" 6" LENGTH 44' 50' 50' 24' 12' 23' 50' 50' SLOPE 2.00% 2.00% 2.00% 26.28% 10.00% 1.00% 2.00% 2.00% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC CLEANOUT INFORMATION CLEANOUT RDCO RD2 20 CO STA: 5+62.16, 41.50' L RDCO RD2 21 CO STA: 6+11.84, 41.50' L INFORMATION RIM = 357.03 IE = 353.49 (6" E) IE = 353.49 (6" W) IE = 353.49 (6" N) RIM = 358.34 IE = 354.48 (6" W) IE = 354.48 (6" N) ROOF RUNOFF NOTE ROOF RUNOFF FROM THE ROOFS OF LOTS 45-50 SHALL BE DISPERSED WITHIN PRIVATE SYSTEMS TO THE WETLAND BUFFER.2 C5.5 KEYNOTES CLEANOUT FOR DISPERSAL TRENCH. STUB ROOF DRAIN THROUGH SITE WALL.1 STORM STRUCTURE TABLE STRUCTURE NAME DISPTRNCH CO-LOT45 N 596036.12 E 1106607.55 DISPTRNCH CO-LOT46 N 596074.23 E 1106641.07 DISPTRNCH CO-LOT47 N 596105.71 E 1106680.38 DISPTRNCH CO-LOT48 N 596140.56 E 1106719.21 DISPTRNCH CO-LOT49 N 596181.53 E 1106776.49 DISPTRNCH CO-LOT50 N 596197.00 E 1106803.54 STRUCTURE DETAILS RIM = 350.25 IE = 338.27 (6" NW) RIM = 351.11 IE = 338.27 (6" NW) RIM = 351.75 IE = 338.27 (6" NW) RIM = 352.25 IE = 338.27 (6" NW) RIM = 352.75 IE = 338.27 (6" NW) RIM = 353.25 IE = 338.27 (6" NW) PIPE TABLE NAME DISP TRNCH PIPE - LOT 45 DISP TRNCH PIPE - LOT 46 DISP TRNCH PIPE - LOT 47 DISP TRNCH PIPE - LOT 48 DISP TRNCH PIPE - LOT 49 DISP TRNCH PIPE - LOT 50 SIZE 6" 6" 6" 6" 6" 6" LENGTH 10' 6' 6' 6' 6' 6' SLOPE 15.00% 22.88% 22.88% 22.88% 22.88% 22.88% MATERIAL PVC PVC PVC PVC PVC PVC N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SE E S H E E T C3 . 1 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX SEE SHEET C3.3 DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-GRAD-STRM.dwg C3.2 12 GRADING AND ROOF DRAINAGE PLAN (NW) WETLAND BUFFER EDGE OF WETLAND J A C K S O N S T . S E ROAD 2 BERRY VALLEY ROAD SE DETENTION/ WETPOND #1 LEVEL-SPREADER DISPERSION TRENCH DISCHARGE WETLAND BUFFER 1 C5.5 3'± HIGH RETAINING WALL. BIDDER DESIGN 33' 49' 1 1 1 1 1 1 1 C5.5 10/09/2024 JA C K S O N S T S E 108 106 105 25 TRACT 'I' 2 42 41 46 24 1 21 22 18 23 38 TRACT 'L' 107 109 43 45 TRACT 'H' 44 3 102 103 14 13 12 11 10 9 8 15 7 31 28 31 18 38 6 9 29 18 38 36 37 35 34 33 11 5 4 20 19 16 17 6 13 12 11 10 9 8 7 30 27 26 39 40 32 s s s s s s s s s s s s s s s s s s s s s s s s s s ss ss ss ss s s ss s s s s s s s s s s 2+0 0 3 6 4 351 35 2 35 1 357 35 3 3 5 7 3 5 1 35 1 38 2 38 9 385386 369 379 384 377378 369 36 7 36 8 37 7 3 7 5 3 7 6 355 360 365 3 5 5 3 6 0 3 6 5 3 7 0 3 7 5 35 0 35 5 36 0 36 5 37 0 36 0 36 5 36 5 35 8 35 8 35 8 35 9 36 1 36 2 36 3 36 4 DISPERSION TRENCH (TYP.) Horizontal 3 : 1 3:1 2:1 2:1 3:1 9:1 2 : 1 2:1 2:1 2:1 2:1 2 : 1 2 : 1 2 : 1 2 : 1 2:1 2:1 2 : 1 PAD 358.00PAD 357.00 PAD 356.00 PAD 355.00PAD 354.00 PAD 352.50 PAD 351 . 2 2 PAD 367.77PAD 365.27 PAD 363.77 PAD 363.15 PAD 363.00 PAD 363.10 PAD 363.80 PAD 364.15 PAD 364.50 PAD 365.00 PAD 365.35 PAD 365.75 PAD 367.00 PAD 367.58 PAD 375.00 PAD 378.00 PAD 379.75 PAD 380.75 PAD 380.80PAD 381.00 PAD 381.00 PAD 377.25 PAD 375.25 PAD 373.00 PAD 371.25 PAD 369.50 PAD 368.00 PAD 367.25 PAD 366.75 PAD 366.25 PAD 365.75 PAD 365.25 PAD 364.75 PAD 364.25 PAD 363.50 PAD 351 . 7 5 PAD 351 . 2 5 PAD 350 . 7 5 PAD 350 . 2 5 PAD 350 . 6 0 PAD 361.50 PAD 363.40 PAD 366.15 PAD 366.50 PAD 370.00 PAD 381.25 TW: 369.50 BW: 360.32 BW: 356.36 TW: 368.00 BW: 362.55 TW: 368.00 BW: 367.25 TW: 367.25 BW: 374.45 TW: 374.58 BW: 375.00 TW: 375.00 TW: 363.77 BW: 363.77 BW: 361.50 TW: 365.27 BW: 362.50 TW: 367.77 BW: 365.25 TW: 365.25 TW: 358.00 TW: 363.50 TW: 363.50 BW: 358.00 BW: 358.00 BW: 363.71 TW: 371.25 TW: 373.00 TW: 373.00 BW: 361.64 BW: 364.50 BW: 372.93 BW: 340.30 TW: 350.29 BW: 350.27 BW: 367.71 TW: 367.98 BW: 367.00 TW: 367.94 BW: 366.50 TW: 369.14 BW: 365.75 TW: 366.16 BW: 365.75 TW: 369.32 BW: 365.35 TW: 368.80 BW: 365.00 TW: 367.96 BW: 364.50 TW: 368.08 BW: 364.15 TW: 368.05 BW: 363.80 TW: 367.41 BW: 363.40 TW: 366.76 BW: 363.10 TW: 366.35 BW: 363.10 TW: 364.80 BW: 363.00 TW: 363.00 CB#16 RIM: 368.25CB#14 RIM: 369.80 CB#15 RIM: 368.33 CB#17 RIM: 366.50 CB#18 RIM: 366.42 CB#21 RIM: 363.51 CB#19 RIM: 364.40 CB#20 RIM: 363.65 CB#22 RIM: 364.46 CB#23 RIM: 364.13 CB#24 RIM: 364.13 CNTRL#2 RIM: 358.84 CB#35 RIM: 351.45 CB#34 RIM: 351.45 CB#32 RIM: 350.45 CB#33 RIM: 350.43 OUTLET FROM SOUTH POND IE: 351.50 18" (SW) OUTLET TO SOUTH POND IE: 353.00 12" (E) OUTLET SOUTH POND IE: 352.75 18" (N) RDCO RD2 5 RDCO RD2 4 RDCO RD2 3 RDCO RD2 2 RDCO RD2 1 RDCO RD2 6 RDCO RD2 7 RDCO RD1 3 RDCO RD1 2 RDCO RD1 1 RDCO JX 34 RDCO JX 33 RDCO JX 32 RDCO JX 31 RDCO JX 30 RDCO JX 29 RDCO JX 28 RDCO JX 27 RDCO JX 26 RDCO JX 25 RDCO JX 24 RDCO JX 23 RDCO JX 22 RDCO JX 21 RDCO JX 9 RDCO JX 8 RDCO JX 7 RDCO JX 5 RDCO JX 4 RDCO JX 3 RDCO JX 12 RDCO JX 13 RDCO JX 14 RDCO JX 15 RDCO JX 17 RDCO JX 18 RDCO JX 20 RDCO JX 2 RDCO JX 1 RDCO JX 11 RDCO JX 16 RDCO JX 6 RDCO JX 19 RDCO JX 35 RDCO JX 10 JX -P 34 JX -P 33 JX -P 29 JX -P 32 JX - P 3 1 J X -P 2 8 JX -P 37 JX -P 19 JX -P 18 JX -P 16 JX -P 27 JX -P 26 JX -P 25 JX -P 24 JX -P 23 JX -P 22 JX -P 10 JX -P 7 JX -P 5 J X - P 3 JX -P 21 JX -P 15 JX -P 14 JX -P 13 JX -P 35 JX -P 36 RD1 -P 4 RD1 -P 1 RD2 -P 4 RD2 -P 12 RD2 -P 7 RD2 - P 1 1 RD2 -P 8 RD2 -P 5 RD2 -P 6 RD2 -P 9 RD2 - P 1 0 RD1 -P 3 JX -P 8 JX -P 2 JX -P 1JX -P 11 RD2 -P 1 JX -P 20 JX -P 17 JX -P 6 J X - P 4 JX -P 9 2 C5.5 PAD GRADE NOTES 1.ALL PAD GRADES SHOWN ARE STRUCTURAL PAD GRADES. SITE WALL NOTES 1.SEE DETAIL 1 SHEET C3.0 FOR WALL LABELING NOMENCLATURE. CLEANOUT INFORMATION CLEANOUT RDCO JX 1 CO STA: 2+73.13, 36.50' R RDCO JX 2 CO STA: 3+08.64, 35.95' R RDCO JX 3 CO STA: 3+32.89, 36.01' R RDCO JX 4 CO STA: 3+65.12, 36.27' R RDCO JX 5 CO STA: 4+02.81, 36.40' R RDCO JX 6 CO STA: 4+16.32, 36.19' R RDCO JX 7 CO STA: 4+76.29, 36.26' R RDCO JX 8 CO STA: 4+99.24, 36.83' R RDCO JX 9 CO STA: 6+10.88, 36.30' R RDCO JX 10 CO STA: 6+31.32, 36.34' R RDCO JX 11 CO STA: 2+73.26, 41.50' L RDCO JX 12 CO STA: 3+71.02, 41.50' L RDCO JX 13 CO STA: 3+82.22, 41.50' L RDCO JX 14 CO STA: 4+18.96, 41.85' L RDCO JX 15 CO STA: 4+61.22, 41.93' L INFORMATION RIM = 381.78 IE = 378.48 (6" N) IE = 378.48 (6" E) RIM = 382.08 IE = 378.29 (6" S) IE = 378.29 (6" N) IE = 378.29 (6" E) RIM = 381.26 IE = 377.99 (6" N) IE = 377.99 (6" S) IE = 377.99 (6" NE) RIM = 380.24 IE = 376.40 (6" SE) IE = 376.40 (6" NW) IE = 376.40 (6" NE) RIM = 378.00 IE = 374.38 (6" SE) IE = 374.38 (6" NW) IE = 374.38 (6" NE) RIM = 377.52 IE = 372.70 (6" SE) IE = 372.70 (6" NW) RIM = 374.88 IE = 371.77 (6" S) IE = 371.77 (6" N) IE = 371.77 (6" E) RIM = 373.74 IE = 367.77 (6" S) IE = 367.77 (6" N) RIM = 369.54 IE = 366.91 (6" SW) IE = 366.91 (6" NE) IE = 366.91 (6" SE) RIM = 368.69 IE = 366.75 (6" SW) IE = 366.75 (8" NW) RIM = 381.00 IE = 377.57 (6" N) IE = 377.57 (6" W) RIM = 380.85 IE = 377.19 (6" NW) IE = 377.19 (6" SE) IE = 377.19 (6" SW) RIM = 377.25 IE = 374.76 (6" SE) IE = 374.76 (6" NW) RIM = 377.25 IE = 373.96 (6" SE) IE = 373.96 (6" NW) IE = 373.96 (6" SW) RIM = 375.54 IE = 372.89 (6" S) IE = 372.89 (6" N) IE = 372.89 (6" W) CLEANOUT INFORMATION CLEANOUT RDCO JX 16 CO STA: 4+69.64, 41.76' L RDCO JX 17 CO STA: 5+02.70, 41.68' L RDCO JX 18 CO STA: 5+44.94, 41.66' L RDCO JX 19 CO STA: 5+53.84, 41.51' L RDCO JX 20 CO STA: 5+76.45, 41.52' L RDCO JX 21 CO STA: 6+96.47, 36.57' R RDCO JX 22 CO STA: 7+36.90, 36.45' R RDCO JX 23 CO STA: 7+76.97, 36.56' R RDCO JX 24 CO STA: 7+97.33, 36.29' R RDCO JX 25 CO STA: 8+56.68, 36.46' R RDCO JX 26 CO STA: 8+96.76, 36.69' R RDCO JX 27 CO STA: 9+36.78, 36.39' R RDCO JX 28 CO STA: 9+77.02, 36.38' R RDCO JX 29 CO STA: 10+11.52, 36.51' R RDCO JX 30 CO STA: 10+47.15, 36.58' R INFORMATION RIM = 373.09 IE = 370.48 (6" S) IE = 370.48 (6" N) RIM = 373.00 IE = 369.65 (6" S) IE = 369.65 (6" N) IE = 369.65 (6" W) RIM = 371.25 IE = 368.59 (6" S) IE = 368.59 (6" N) IE = 368.59 (6" W) RIM = 369.73 IE = 367.14 (6" S) IE = 367.14 (6" N) RIM = 369.50 IE = 366.57 (6" SW) IE = 366.57 (8" SE) IE = 366.57 (6" NW) RIM = 368.04 IE = 365.79 (6" NE) IE = 366.69 (6" SE) RIM = 367.05 IE = 365.30 (6" SW) IE = 365.30 (6" NE) IE = 364.09 (6" SE) RIM = 366.64 IE = 364.70 (6" SW) IE = 364.70 (6" NE) IE = 363.29 (6" SE) RIM = 366.59 IE = 364.30 (6" SW) IE = 364.30 (8" NW) IE = 362.89 (6" SE) RIM = 365.94 IE = 362.60 (6" NE) IE = 362.60 (6" SE) RIM = 365.45 IE = 362.20 (6" SW) IE = 362.20 (6" NE) IE = 362.20 (6" SE) RIM = 365.15 IE = 361.80 (6" SW) IE = 361.80 (6" NE) IE = 364.80 (6" SE) RIM = 364.95 IE = 361.40 (6" SW) IE = 361.40 (6" NE) IE = 361.40 (6" SE) RIM = 364.60 IE = 361.01 (6" SW) IE = 361.01 (6" NE) IE = 361.01 (6" SE) RIM = 364.27 IE = 360.60 (6" NE) IE = 360.60 (6" SE) IE = 360.60 (6" SW) CLEANOUT INFORMATION CLEANOUT RDCO JX 31 CO STA: 10+77.13, 36.54' R RDCO JX 32 CO STA: 11+12.05, 36.51' R RDCO JX 33 CO STA: 11+45.28, 36.58' R RDCO JX 34 CO STA: 11+55.84, 42.70' R RDCO JX 35 CO STA: 10+05.96, 41.62' L RDCO RD1 1 CO STA: 1+47.73, 42.72' L RDCO RD1 2 CO STA: 12+24.20, 86.50' R RDCO RD1 3 CO STA: 2+39.29, 41.46' L INFORMATION RIM = 364.04 IE = 360.25 (6" SW) IE = 360.25 (6" NE) IE = 360.25 (6" E) RIM = 363.38 IE = 359.85 (6" S) IE = 359.85 (6" N) IE = 359.85 (6" E) RIM = 363.33 IE = 359.46 (6" S) IE = 359.46 (6" N) IE = 359.46 (6" E) RIM = 363.15 IE = 359.32 (6" SW) IE = 359.32 (8" N) RIM = 364.34 IE = 361.15 (8" SE) IE = 361.15 (6" NW) RIM = 364.12 IE = 361.35 (6" E) IE = 361.35 (8" S) IE = 361.35 (6" N) RIM = 365.27 IE = 362.61 (6" E) IE = 362.61 (6" W) IE = 362.61 (6" N) RIM = 367.77 IE = 364.11 (6" W) IE = 364.11 (6" N) PIPE TABLE NAME JX -P 1 JX -P 2 JX -P 3 JX -P 4 JX -P 5 JX -P 6 JX -P 7 JX -P 8 JX -P 9 JX -P 10 JX -P 11 JX -P 13 JX -P 14 SIZE 6" 6" 6" 6" 6" 6" 6" 6" 6" 8" 6" 6" 6" LENGTH 10' 30' 40' 40' 11' 46' 18' 86' 16' 18' 10' 10' 40' SLOPE 0.50% 1.00% 4.00% 5.00% 15.11% 2.00% 22.57% 1.00% 1.00% 2.25% 0.50% 25.00% 2.00% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PIPE TABLE NAME JX -P 15 JX -P 16 JX -P 17 JX -P 18 JX -P 19 JX -P 20 JX -P 21 JX -P 22 JX -P 23 JX -P 24 JX -P 25 JX -P 26 JX -P 27 SIZE 6" 6" 6" 6" 6" 6" 8" 6" 6" 6" 8" 6" 6" LENGTH 53' 11' 42' 53' 11' 28' 24' 40' 40' 20' 17' 40' 40' SLOPE 2.00% 22.69% 2.00% 2.00% 12.93% 2.00% 4.41% 1.20% 1.50% 2.00% 2.00% 1.00% 1.00% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PIPE TABLE NAME JX -P 28 JX -P 29 JX -P 31 JX -P 32 JX -P 33 JX -P 34 JX -P 35 JX -P 36 JX -P 37 SIZE 6" 6" 6" 6" 6" 6" 6" 8" 8" LENGTH 40' 39' 41' 35' 40' 39' 14' 26' 24' SLOPE 1.00% 1.00% 1.00% 1.00% 1.00% 1.00% 1.00% 13.75% 1.00% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PIPE TABLE NAME RD1 -P 1 RD1 -P 3 RD1 -P 4 SIZE 8" 6" 6" LENGTH 35' 36' 50' SLOPE 4.87% 3.00% 3.00% MATERIAL PVC PVC PVC KEYNOTES CLEANOUT FOR DISPERSAL TRENCH. STUB ROOF DRAIN THROUGH SITE WALL. CLEANOUT FOR DISPERSAL TRENCH. 1 2 STORM STRUCTURE TABLE STRUCTURE NAME DISPTRNCH CO-LOT32 N 595515.75 E 1106721.93 DISPTRNCH CO-LOT33 N 595575.53 E 1106784.50 DISPTRNCH CO-LOT34 N 595610.67 E 1106825.07 DISPTRNCH CO-LOT35 N 595641.41 E 1106865.66 DISPTRNCH CO-LOT37 N 595705.35 E 1106948.15 DISPTRNCH CO-LOT38 N 595733.49 E 1106980.66 DISPTRNCH CO-LOT39 N 595756.07 E 1107010.37 DISPTRNCH CO LOT36 N 595672.17 E 1106903.55 STRUCTURE DETAILS RIM = 368.00 IE = 338.27 (6" NW) RIM = 367.25 IE = 338.27 (6" NW) RIM = 366.75 IE = 338.27 (6" NW) RIM = 366.25 IE = 338.27 (6" NW) RIM = 365.17 IE = 338.27 (6" NW) RIM = 364.75 IE = 338.27 (6" NW) RIM = 364.25 IE = 338.27 (6" NW) RIM = 365.75 IE = 338.27 (6" NW) PIPE TABLE NAME DISP TRNCH PIPE - LOT 32 DISP TRNCH PIPE - LOT 33 DISP TRNCH PIPE - LOT 34 DISP TRNCH PIPE - LOT 35 DISP TRNCH PIPE - LOT 36 DISP TRNCH PIPE - LOT 37 DISP TRNCH PIPE - LOT 38 DISP TRNCH PIPE - LOT 39 SIZE 6" 6" 6" 6" 6" 6" 6" 6" LENGTH 21' 34' 36' 36' 33' 28' 21' 21' SLOPE 6.93% 4.27% 4.04% 4.00% 4.38% 5.24% 6.88% 7.10% MATERIAL PVC PVC PVC PVC PVC PVC PVC PVC N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SEE SHEET C3.2 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-GRAD-STRM.dwg C3.3 13 GRADING AND ROOF DRAINAGE PLAN (S) WETLAND BUFFER EDGE OF WETLAND ROAD 1 JACK S O N S T . S E DETENTION/WETPOND #2 10'± MAX HEIGHT RETAINING WALL. BIDDER DESIGN. ROOF RUNOFF NOTE ROOF RUNOFF FROM THE ROOFS OF LOTS 32-39 SHALL BE DISPERSED WITHIN PRIVATE SYSTEMS TO THE WETLAND BUFFER. 2 C5.5 42' 58' 76' 40' 50' 4'± MAX HEIGHT RETAINING WALL. BIDDER DESIGN. 3'± MAX HEIGHT RETAINING WALL. BIDDER DESIGN. 1 1 2 2 2 2 2 2 6" DEPTH GRAVEL MAINTENANCE ACCESS PATH 10/09/2024 929394 84 69 61 68 60 6766 656463 70 62 2 71 83 72 80 TRACT 'B' 82 81 TRACT 'A' 79 76 77 78 74 75 73 1 59 91 89 88 87 85 98 97 8690 TRACT 'L' 104 55 TR A C T ' D ' TR A C T ' C ' 3 102 100 99 9596 103 101 s s s s s s s s s ss s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 2+00 3+003+00 S 6 ° 1 9 ' 5 2 " E 1 0 1 . 0 0 ' CB#28 CB#2 CB#1 CB#3 CB#4 CB#5 CB#6 CB#7 CB#8 CB#9 CB#10 CB#11 CB#12 OUTLET TO WQ STRUCTURE 350 34 8 35 2 35 4 35 6 358 35 8 3 5 6 3 5 4 3 5 2 35 0 34 8 346 344 342 340 332 3 6 4 3 6 2 360 358 356 354 352 36 6 364 362 360 3 5 8 368 3 3 0 3 3 2 35 036 0 35 2 35 4 35 6 35 8 36 2 356358 346364 3 7 6 350 PC : 7 + 0 8 . 7 3 PT: 8 + 3 6 . 1 3 PC: 1 0 + 4 6 . 3 4 PT : 1 1 + 7 6 . 2 8 PC : 1 2 + 5 4 . 8 3 PT : 1 2 + 9 9 . 0 4 PC : 1 3 + 0 3 . 8 2 338 340 336 338 35 4 35 6 35 8 35 2 35 4 35 4 35 6 356356 35 6 35 8 35 8 352 34 6 34 8 35 0 35 2 35 4 360358362 360 362364 3 6 4 3 6 0 STA: 7+06.91 ROAD 2= STA: 14+37.61 JACKSON 360362 364 366 2+00 3+00 4+00 5+00 6+00 7+00 8 + 0 0 9 + 0 0 1 0 + 0 0 1 1 + 0 0 12+00 13 + 0 0 7+00 STA: 1+00 BERRY VALLEY= STA: 16+06.86 JACKSON 35 4 35 6 358 STA: 5+15.77 BERRY VALLEY= STA: 2+75.47 ROAD 3 STA:2+84.45 END ROAD IMPROVEMENTS CB#13 RD OUTLET TO EAST POND 320 325 330 335 340 345 350 355 360 365 370 375 320 325 330 335 340 345 350 355 360 365 370 375 320 325 330 335 340 345 350 355 320 325 330 335 340 345 350 355 1+00 35 0 . 9 9 35 0 . 4 9 1+50 35 0 . 2 0 35 0 . 3 6 2+00 35 0 . 9 5 35 1 . 9 9 2+50 35 3 . 2 4 35 4 . 4 9 3+00 35 5 . 6 5 35 6 . 6 3 3+50 35 7 . 4 3 35 8 . 0 5 4+00 35 8 . 4 9 35 8 . 7 5 4+50 35 8 . 8 3 35 8 . 7 4 5+00 35 8 . 4 6 35 8 . 0 0 5+50 35 7 . 3 6 35 6 . 5 5 6+00 35 5 . 5 5 35 4 . 3 8 6+50 35 3 . 0 2 35 1 . 4 9 34 8 . 2 4 7+50 34 6 . 6 1 34 4 . 9 9 8+00 34 3 . 3 6 34 1 . 8 3 8+50 34 0 . 4 8 33 9 . 3 1 9+00 33 8 . 3 3 33 7 . 5 3 9+50 33 6 . 9 2 33 6 . 4 0 10+00 33 5 . 8 8 33 5 . 3 5 10+50 33 4 . 8 3 33 4 . 3 1 11+00 33 3 . 7 9 33 3 . 2 7 11+50 33 2 . 7 4 33 2 . 2 2 12+00 33 1 . 7 4 33 1 . 3 5 12+50 33 1 . 0 3 33 0 . 8 1 13+00 33 0 . 6 2 33 0 . 4 3 GRADE BREAK STA: 1+00.00 ELEV: 350.99 PVI: 364.49 PVI STA: 4+75.00 K: 34.78 400' VC BV C S : 2 + 7 5 . 0 0 BV C E : 3 5 4 . 4 9 EV C S : 6 + 7 5 . 0 0 EV C E : 3 5 1 . 4 9 HI P T : 4 + 4 8 . 9 1 EL E V : 3 5 8 . 8 3 PROPOSED SEWER FM 2.00% 5.00% PVI: 349.49 PVI STA: 1+75.00 K: 14.29 100' VC BV C S : 1 + 2 5 . 0 0 BV C E : 3 5 0 . 4 9 EV C S : 2 + 2 5 . 0 0 EV C E : 3 5 1 . 9 9 LO W P T : 1 + 5 3 . 5 7 EL E V : 3 5 0 . 2 0 6. 5 0 % 2.09% PVI: 338.49 PVI STA: 8+75.00 K: 34.00 150' VC BV C S : 8 + 0 0 . 0 0 BV C E : 3 4 3 . 3 6 EV C S : 9 + 5 0 . 0 0 EV C E : 3 3 6 . 9 2 PVI: 331.18 PVI STA: 12+25.00 K: 74.35 100' VC BV C S : 1 1 + 7 5 . 0 0 BV C E : 3 3 2 . 2 2 EV C S : 1 2 + 7 5 . 0 0 EV C E : 3 3 0 . 8 1 PROPOSED WATER MAIN STA: 2+43.75, 15.50' L IE: 353.89 12" (E) IE: 354.39 8" (SW) RIM: 357.95 CB#3, CB TYPE 1 STA: 2+43.75, 15.50' R IE: 353.58 12" (W) IE: 353.58 12" (NE) RIM: 357.32 CB#4, CB TYPE 1 STA: 5+61.77, 14.92' R IE: 352.42 12" (SW) IE: 352.42 12" (E) RIM: 356.64 CB#5, CB TYPE 1 STA: 7+81.70, 14.92 R IE: 340.68 12" (W) IE: 340.68 12" (SE) RIM: 344.19 CB#8, CB TYPE 1 STA: 7+34.18, 14.92 L IE: 344.27 12" (S) IE: 344.00 8" (NE) RIM: 347.28 CB#7, CB TYPE 1 STA: 7+34.18, 14.92 R IE: 344.12 12" (W) IE: 344.12 12" (E) IE: 344.12 12" (N) RIM: 347.28 CB#6, CB TYPE 1 STA: 8+50, 14.92 R IE: 336.95 12" (NW) IE: 336.95 12" (SE) IE: 336.91 12" (NE) RIM: 340.12 CB#9, CB TYPE 1 STA: 8+50, 14.92 L IE: 337.06 12" (SW) IE: 337.49 8" (NE) RIM: 340.12 CB#10, CB TYPE 1 STA: 10+50, 14.92' R IE: 331.52 12" (NW) IE: 331.52 12" (NE) RIM: 334.47 CB#11, CB TYPE 1 STA: 10+50, 14.92 L IE: 331.37 12" (SW) IE: 331.37 12" (NE) RIM: 334.47 CB#12, CB TYPE 1 31 LF 12" CPEP @ 1.00% 35 LF 12" CPEP @ 3.34% 17 0 L F 1 2 " C P E P @ 4 . 8 9 % 30 LF 12" CPEP @ 0.51%30 LF 12" CPEP @ 0.51% 62 L F 1 2 " C P E P @ 5 . 9 8 % 4 3 L F 1 2 " C P E P @ 8 . 0 7 % 200 L F 1 2 " C P E P @ 2 . 7 1 % 30 LF 12" CPEP @ 0.51% STA: 1+53.57, 14.92 L IE: 343.60 12" (S) IE: 345.74 8" (N) RIM: 349.84 CB#1, CB TYPE 1 STA: 1+53.57, 14.92 R IE: 343.00 12" (N) IE: 343.00 12" (W) IE: 345.59 8" (S) RIM: 349.84 CB#2, CB TYPE 1 STA: 15+77.36, 14.08 L IE: 341.31 12" (N) IE: 341.31 12" (W) IE: 341.31 12" (E) IE: 341.31 12" (S) RIM: 352.39 CB#28, 48" TYPE 2 CB N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.4 14 BERRY VALLEY ROAD BERRY VALLEY ROAD SE PROFILE (STA. 1+00 - STA. 13+50) HORIZ. 1"=50', VERT. 1"=5' BERRY VALLEY ROAD SE PLAN - NEIGHBORHOOD COLLECTOR (STA. 1+00 - STA. 13+50) 1"=50' BERRY VALLEY ROAD SE EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD SEE C3.8SEE C3.7 SEE C3.7 RO A D 3 JA C K S O N S T S E SE E C3 . 5 A C3.9 INFILTRATION TRENCH (TYP.) 10' UTILITY EASEMENT (TYP.) 56' ROW 10' UTILITY EASEMENT (TYP.) SEE SHEET C5.3 FOR TRACT A POND DESIGN 10/09/2024 TRACT 'J' TRACT 'K' CB#41 CB#40 CB#39 CB#41 1.10 ROW DEDICATION EXISTING ROW S80° 39' 28"W PROPOSED ROW S80° 33' 09"W 26.00 16.0 16.0 CB#42 10.0 CENTERLINE PROPOSED ROAD N80° 33' 09"E OUTLET TO WQ STRUCTURE PC : 1 2 + 5 4 . 8 3 PT: 1 2 + 9 9 . 0 4 PC : 1 3 + 0 3 . 8 2 PT : 1 4 + 0 6 . 1 3 330 33 0328328 1 3 + 0 0 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 30 LF 12" DI @ 0.50% OUTLET TO TRACT K POND IE: 325.50 12" (S) 26.0 1 C3.5 21 LF 12" DI @ 0.38% PARCEL # 21724230101 JENKINS, TAMMY M PARCEL # 21724230400 GERRISH FAMILY REVOCABLE LIVING TRUST PARCEL # 21724230100 PURVIS, DAVID A 330 326328 STA:14+65.75, 16.50' L BEGIN TAPER STA:15+15.75, 23.00' L END TAPER STA:14+42.86, 16.00' R BEGIN TAPER STA:15+32.86, 10.00' R END TAPER SEE SHEET C5.4 FOR TRACT K POND DESIGN WORK EAST OF STATION 18+00 IS COVERED UNDER A SEPARATE ROW PERMIT FOR BERRY VALLEY ROAD OFFSITE IMPROVEMENTS 3: 1 RD OUTLET TO EAST POND 315 320 325 330 335 340 345 315 320 325 330 335 340 345 13+50 33 0 . 2 5 33 0 . 0 6 14+00 32 9 . 8 8 32 9 . 6 9 14+50 32 9 . 5 1 32 9 . 3 2 15+00 32 9 . 1 3 32 8 . 9 5 15+50 32 8 . 7 6 32 8 . 5 8 16+00 32 8 . 3 9 32 8 . 2 1 16+50 32 8 . 0 5 32 7 . 9 6 17+00 32 7 . 9 4 32 7 . 9 7 17+50 32 8 . 0 7 32 8 . 2 3 18+00 32 8 . 4 2 32 8 . 6 1 18+50 32 8 . 8 0 32 8 . 9 9 19+00 32 9 . 1 8 32 9 . 3 7 19+50 32 9 . 5 9 32 9 . 8 4 20+00 33 0 . 1 2 33 0 . 3 9 20+50 33 0 . 6 6 0.74%0.76% 1.10% PVI: 327.66 PVI STA: 16+99.04 K: 99.83 150' VC BV C S : 1 6 + 2 4 . 0 4 BV C E : 3 2 8 . 2 1 EV C S : 1 7 + 7 4 . 0 4 EV C E : 3 2 8 . 2 3 LO W P T : 1 6 + 9 8 . 2 0 EL E V : 3 2 7 . 9 4 PVI: 329.55 PVI STA: 19+48.86 K: 147.86 50' VC BV C S : 1 9 + 2 3 . 8 6 BV C E : 3 2 9 . 3 6 EV C S : 1 9 + 7 3 . 8 6 EV C E : 3 2 9 . 8 3 STA: 14+41.44, 14.92 L IE: 327.06 12" (S) IE: 327.06 12" (E) RIM: 329.21 CB#40, CB TYPE 1 STA: 16+98.20, 14.92 L IE: 325.58 12" (W) IE: 325.58 12" (N) RIM: 327.58 CB#41, CB TYPE 1 STA: 17+87.74, 14.92 R IE: 324.98 12" (S) RIM: 328.03 CB#42, CB TYPE 1 PROPOSED WAT E R M A I N 21 LF 12" DI CL52 @ 0.38% 257 LF 12" DI CL52 @ 0.58 % 15 LF 12" CPEP @ 0.50% 30 LF 12" DI CL52 @ 0.50% STA: 14+41.44, 14.92 R IE: 327.21 12" (N) RIM: 329.21 CB#39, CB TYPE 1 0.42' ROW DEDICATION 32.0 5.5 5.5 1.50' BACK OF SW TO ROW PROPOSED HEADWALL PER GEOTECHNICAL DESIGN EDGE OF WETLAND (THOMPSON CREEK) PT : 1 4 + 0 6 . 1 3 330 14+00 CB#39 30 L F 1 2 " D I @ 0 . 5 0 % CB#40 STA:14+42.86, 16.00' R END CONCRETE CURB, GUTTER AND SIDEWALK START OF GRAVEL SHOULDER 13+71.24, 21.51' R TW: 330.33 BW: 330.33 13+78.19, 21.54' R TW: 330.28 BW: 328.37 13+95.00, 21.54' R TW: 330.15 BW: 327.32 14+45.16, 21.50' R TW: 327.73 BW: 327.03 14+41.70, 21.50' R TW: 329.81 BW: 326.39 14+20.00, 21.50' R TW: 329.97 BW: 324.20 PROPOSED ARCH PIPE AND FOOTINGS 330 326 328 3: 1 PROVIDE PEDESTRIAN RAILING 1 C3.9 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.5 15 BERRY VALLEY ROAD BERRY VALLEY ROAD SE PROFILE (STA. 13+50 - STA. 21+00) HORIZ. 1"=50', VERT. 1"=5' BERRY VALLEY ROAD SE PLAN - NEIGHBORHOOD COLLECTOR (STA. 13+50 - STA. 20+50) 1"=50' BERRY VALLEY ROAD SE EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD SE E C3 . 4 WETLAND BUFFER SE E O F F S I T E I M P R O V E M E N T S B C3.9 ROW DEDICATION WIDTH VARIES MATCH CL BEARING 7.0 5.0 C C3.9 WETLAND BUFFER PE R M I T N O . PROPOSED 8'-9" SPAN x 2'-6" RISE CULVERT 1 SCALE: 1" = 10' ENLARGEMENT N 1 C3.12 10/09/2024 JACKSON ST SE 28 31 25 24 21 22 18 23 38 36 37 35 13 12 11 31 20 19 4400 S.F. 11 28 31 18 38 18 38 14 13 12 11 16 15 17 39 40 34 33 32 27 26 s s s s s s s s s s s s s s s s s s s s s s s s s ss s 1+00 2+00 3+00 4+00 5+00 6 + 0 0 7 + 0 0 8 + 0 0 9 + 0 0 CB#18 CB#17 CB#15 CB#14 CB#16 382384386388390392 394 3 8 0 3 7 6 3 7 8 3 8 2 3 8 4 3 7 0 3 7 2 3 7 4 3 7 8 3 7 2 3 7 4 370 366 368 37 0 366 36 8 37 2 3 7 4 3 8 0 3 7 8 364 364 STA:2+89.68, 17.50' R EDGE OF PAVEMENT STA:2+89.59, 17.50' L EDGE OF PAVEMENT STA:1+00.26, 3.84' L STA:2+28.12, 14.84' R EDGE OF PAVEMENT MATCH EXISTING ROLLED CURB STA:2+28.27, 20.24' L EDGE OF PAVEMENT MATCH EXISTING ROLLED CURB 370 3 8 0 36 6 368 37 237 4 37 6 3 7 8 382 3 6 0 3 5 4 3 5 6 3 5 8 3 6 2 3 6 4 3 6 6 355 360 365 370 375 380 385 390 395 355 360 365 370 375 380 385 390 395 1+00 1+50 2+00 38 0 . 9 4 2+50 38 1 . 7 8 38 2 . 2 6 3+00 38 2 . 2 9 38 1 . 8 8 3+50 38 1 . 0 3 37 9 . 8 1 4+00 37 8 . 5 6 37 7 . 3 1 4+50 37 6 . 0 6 37 4 . 8 1 5+00 37 3 . 5 6 37 2 . 3 3 5+50 37 1 . 2 5 37 0 . 3 3 6+00 36 9 . 5 8 36 8 . 9 9 6+50 36 8 . 5 8 36 8 . 3 0 7+00 36 8 . 0 5 36 7 . 8 0 7+50 36 7 . 5 5 36 7 . 3 0 8+00 36 7 . 0 5 36 6 . 8 0 8+50 36 6 . 5 5 36 6 . 3 0 9+00 36 6 . 0 5 PROPOSED WATER MAIN CB#14, 48" TYPE 2 STA 5+77.02, 17.83' L RIM: 369.80 IE: 365.03 12" (NE) IE: 365.53 8" (NW) STA: 6+31.82, 18.73 R IE: 366.35 12" (NW) IE: 366.35 8" (SE) RIM: 368.25 CB#16, CB TYPE 1 CB#15, 48" TYPE 2 STA 6+31.82, 17.88' L RIM: 368.33 IE: 362.99 12" (SW) IE: 362.99 12" (NE) IE: 366.17 12" (SE) STA: 7+97.70, 18.72' R IE: 363.95 12" (NW) IE: 363.95 8" (SE) RIM: 366.42 CB#18, CB TYPE 1 CB#17, 48" TYPE 2 STA 7+97.79, 17.85L RIM: 366.50 IE: 361.86 12" (SW) IE: 361.86 12" (NE) IE: 363.77 12" (SE)STA: 2+28.26 ELEV: 381.16 BEGIN ROAD IMPROVEMENTS MATCH EXISTING 37 LF 12" CPEP @ 0.50% 37 LF 12" CPEP @ 0.50% 61 LF 12" CPEP @ 3.37% 167 LF 12" CPEP @ 0.68%207 LF 12" CPEP @ 0. 7 0 % 3.50% -5. 0 0 % -1.00% GR A D E B R E A K S T A : 2 + 0 9 . 4 3 EL E V : 3 8 0 . 3 9 PVI: 383.56 PVI STA: 3+00.00 K: 14.12 120' VC BV C S : 2 + 4 0 . 0 0 BV C E : 3 8 1 . 4 6 EV C S : 3 + 6 0 . 0 0 EV C E : 3 8 0 . 5 6 HI P T : 2 + 8 9 . 4 1 EL E V : 3 8 2 . 3 3 3.50% -5. 0 0 % -1.00% GR A D E B R E A K S T A : 2 + 0 9 . 4 3 EL E V : 3 8 0 . 3 9 PVI: 383.56 PVI STA: 3+00.00 K: 14.12 120' VC BV C S : 2 + 4 0 . 0 0 BV C E : 3 8 1 . 4 6 EV C S : 3 + 6 0 . 0 0 EV C E : 3 8 0 . 5 6 HI P T : 2 + 8 9 . 4 1 EL E V : 3 8 2 . 3 3 PVI: 369.18 PVI STA: 5+87.73 K: 37.50 150' VC BV C S : 5 + 1 2 . 7 3 BV C E : 3 7 2 . 9 3 EV C S : 6 + 6 2 . 7 3 EV C E : 3 6 8 . 4 3 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.6 16 JACKSON STREET PLAN & PROFILE JACKSON STREET SE PROFILE (STA. 1+00 - STA. 9+00) HORIZ. 1"=50', VERT. 1"=5' JACKSON STREET SE PLAN - LOCAL ACCESS RESIDENTIAL (STA. 1+00 - STA. 9+00) 1"=50' J A C K S O N S T . S E EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD BEGIN ROAD CONSTRUCTION MATCH EXISTING SEE C3.7 D C3.10 10' UTILITY EASEMENT (TYP.) 56' ROW 10' UTILITY EASEMENT (TYP.) PROPOSED SEWER FORCEMAIN 10/09/2024 106 105 53 54 56 57 61 60 58 2 59 97 38 TRACT 'L' 104 107 55 3 100 99 96 103 98 11 10 9 8 7 38 6 9 38 37 11 5 4 6 11 10 9 8 7 39 40 s s s s s s sss s ss s s s s s s s s s s s ss s s s ss s s s 9 + 0 0 1 0 + 0 0 11+ 0 0 12+00 13+00 14+00 15+00 16+00 17+00 17+50 35 0 34 8 352 364 362 36 0 35 8 35 6 3 5 4 3 5 2 358352 35 4 350 352 3 6 0 3 6 2 3 6 4 364 364 3 6 2 364 35 0 34 8 CB#21 CB#19 CB#20 CB#22 CB#23 CB#24 CB#25 CB#26 CB#27 CB#28 CB#2 CB#1 CB#30 CB#29 STA: 16+06.86 JACKSON= STA: 0+99.94 BERRY VALLEY STA: 11+82.47 JACKSON= STA: 1+00.00 ROAD 1 STA: 14+37.61 JACKSON= STA: 7+06.91 ROAD 2 360 356 358 2+ 0 0 354356 3 5 8 36 6 335 340 345 350 355 360 365 370 375 380 385 335 340 345 350 355 360 365 370 375 380 385 9+00 36 5 . 8 5 36 5 . 6 0 9+50 36 5 . 3 5 36 5 . 1 0 10+00 36 4 . 8 5 36 4 . 6 0 10+50 36 4 . 3 5 36 4 . 1 2 11+00 36 4 . 0 3 36 4 . 0 9 11+50 36 4 . 3 1 36 4 . 6 7 12+00 36 4 . 9 3 36 4 . 8 3 12+50 36 4 . 4 0 36 3 . 9 0 13+00 36 3 . 4 0 36 2 . 9 0 13+50 36 2 . 4 0 36 1 . 9 0 14+00 36 1 . 4 0 36 0 . 7 7 14+50 35 9 . 8 9 35 8 . 7 7 15+00 35 7 . 3 9 35 5 . 8 9 15+50 35 4 . 3 9 35 2 . 8 9 16+00 35 1 . 3 9 34 9 . 9 8 16+50 34 8 . 7 7 34 7 . 7 4 17+00 34 6 . 9 0 34 6 . 0 5 17+50 PVI: 365.20 PVI STA: 12+10.30 K: 17.14 60' VC BV C S : 1 1 + 8 0 . 3 0 BV C E : 3 6 4 . 7 5 EV C S : 1 2 + 4 0 . 3 0 EV C E : 3 6 4 . 6 0 HI P T : 1 2 + 0 6 . 0 1 EL E V : 3 6 4 . 9 4 PVI: 360.40 PVI STA: 14+50.00 K: 25.00 100' VC BV C S : 1 4 + 0 0 . 0 0 BV C E : 3 6 1 . 4 0 EV C S : 1 5 + 0 0 . 0 0 EV C E : 3 5 7 . 4 0 3.00 % 2.00% 6. 0 0 % 1.50% PVI: 348.40 PVI STA: 16+50.00 K: 33.33 100' VC BV C S : 1 6 + 0 0 . 0 0 BV C E : 3 5 1 . 4 0 EV C S : 1 7 + 0 0 . 0 0 EV C E : 3 4 6 . 9 0 PVI: 363.73 PVI STA: 11+12.40 K: 39.98 100' VC BV C S : 1 0 + 6 2 . 4 0 BV C E : 3 6 4 . 2 3 EV C S : 1 1 + 6 2 . 4 0 EV C E : 3 6 4 . 4 8 LO W P T : 1 1 + 0 2 . 4 3 EL E V : 3 6 4 . 0 3 STA: 15+77.36, 14.08' L IE: 341.31 12" (N) IE: 341.31 12" (W) IE: 341.31 12" (E) IE: 341.31 12" (S) RIM: 352.39 CB#28, 48" TYPE 2 CB STA: 11+03.78, 18.50 R IE: 361.24 12" (W) RIM: 363.51 CB#21, CB TYPE 1 STA: 10+07.12, 17.89 L IE: 360.41 12" (SW) IE: 360.41 12" (NE) IE: 360.91 8" (NW) RIM: 364.40 CB#19, 48" TYPE 2 STA: 11+03.80, 17.89 L IE: 359.97 12" (SW) IE: 359.97 12" (N) IE: 359.97 12" (E) RIM: 363.65 CB#20, 48" TYPE 2 STA: 14+26.38, 21.74' L IE: 353.10 12" (N) RIM: 359.94 CB#25, CB TYPE 1 STA: 14+60.96, 18.72' R IE: 354.10 12" (W) IE: 354.60 8" (E) RIM: 358.97 CB#27, CB TYPE 1 STA: 14+60.83, 21.54' L IE: 342.96 12" (W) IE: 342.96 12" (E) IE: 342.96 12" (N) IE: 342.96 12" (S) RIM: 358.68 CB#26, 48" TYPE 2 CB STA: 17+19.86, 14.92' R IE: 342.90 12" (W) RIM: 345.94 CB#30, CB TYPE 1 STA: 11+79.13, 19.15 L IE: 358.29 12" (S) IE: 355.15 12" (W) IE: 355.15 12" (E) RIM: 364.46 CB#22, 48" TYPE 2 STA: 14+37.82 ELEV: 360.36 INTERSECTION ROAD 2 STA: 11+81.53 ELEV: 364.80 INTERSECTION ROAD 1 STA: 16+07.07 ELEV: 350.99 INTERSECTION BERRY VALLEY ROAD SE STA: 17+23.07 ELEV: 346.21 END ROAD IMPROVEMENTS 40 LF 12" CPEP @ 27.67% 36 LF 12" CPEP @ 3.49% 30 LF 12" CPEP @ 2.14% 88 LF 12" CPEP @ 0.50%69 LF 1 2 " C P E P @ 2.44 % 34 LF 12" CPEP @ 29.43% 119 LF 12" C P E P @ 1 . 3 9 % PROPOSED WATER MAIN CB#29, CB TYPE 1 STA 17+19.86, 14.92' L RIM: 345.94 IE: 342.26 12" (E) IE: 342.26 12" (S) IE: 342.76 8" (W) 143 LF 12" CPEP @ 0.67% -2.00% 1.00% GR A D E B R E A K S T A : 1 2 + 7 2 . 5 0 EL E V : 3 6 3 . 9 5 -2.00% 1.00% GR A D E B R E A K S T A : 1 2 + 7 2 . 5 0 EL E V : 3 6 3 . 9 5 PVI: 365.12 PVI STA: 12+14.12 K: 20.01 60' VC BV C S : 1 1 + 8 4 . 1 2 BV C E : 3 6 4 . 8 2 EV C S : 1 2 + 4 4 . 1 2 EV C E : 3 6 4 . 5 2 HI P T : 1 2 + 0 4 . 1 0 EL E V : 3 6 4 . 9 2 PVI: 364.02 PVI STA: 11+03.75 K: 50.03 100' VC BV C S : 1 0 + 5 3 . 7 5 BV C E : 3 6 4 . 5 2 EV C S : 1 1 + 5 3 . 7 5 EV C E : 3 6 4 . 5 2 LO W P T : 1 1 + 0 3 . 7 8 EL E V : 3 6 4 . 2 7 207 LF 12" CPEP @ 0. 7 0 % 365 370 375 380 385 88 LF 12" CPEP 69 LF 1 2 " C P E P -2.00% 1.00%-2.00% 1.00% PVI: 365.12 PVI STA: 12+14.12 K: 20.01 60' VC BV C S : 1 1 + 8 4 . 1 2 BV C E : 3 6 4 . 8 2 EV C S : 1 2 + 4 4 . 1 2 EV C E : 3 6 4 . 5 2 HI P T : 1 2 + 0 4 . 1 0 EL E V : 3 6 4 . 9 2 PVI: 364.02 PVI STA: 11+03.75 K: 50.03 100' VC BV C S : 1 0 + 5 3 . 7 5 BV C E : 3 6 4 . 5 2 EV C S : 1 1 + 5 3 . 7 5 EV C E : 3 6 4 . 5 2 LO W P T : 1 1 + 0 3 . 7 8 EL E V : 3 6 4 . 2 7 207 LF 12" CPEP @ 0.7 0 % N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.7 17 JACKSON STREET PLAN & PROFILE JACKSON STREET SE PROFILE (STA. 9+00 - STA. 17+50) HORIZ. 1"=50', VERT. 1"=5' JACKSON STREET SE PLAN - LOCAL ACCESS RESIDENTIAL (STA. 9+00 - STA. 17+50) 1"=50' JACKSON ST. SE EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD END ROAD CONSTRUCTION MATCH EXISTING R O A D 1 RO A D 2 BE R R Y VA L L E Y SEE C3.6 SEE C3.8 SEE C3.4 SEE C3.8 D C3.10 A C3.9 10' UTILITY EASEMENT (TYP.) 56' ROW 10' UTILITY EASEMENT (TYP.) SEE SHEET C5.2 FOR TRACT L POND DESIGN CONSTRUCT WEDGE CURB AT END OF RAOD 10/09/2024 2 1 TRACT 'L' 3 4 s s s s s 2+00 3+003+00 3 6 4 36 8 3 7 6 3 6 4 CB#24 CB#23 CB#22 STA: 1+00 ROAD 1= STA: 11+82.47 JACKSON STA:2+84.45 END ROAD IMPROVEMENTS 345 350 355 360 365 370 375 380 345 350 355 360 365 370 375 380 0+50 1+00 36 4 . 4 0 1+50 36 4 . 4 9 36 5 . 1 1 2+00 36 6 . 2 2 36 7 . 4 2 2+50 36 8 . 6 2 36 9 . 8 2 3+00 2.00% 4.80% PVI: 363.81 PVI STA: 1+49.75 K: 11.76 80' VC BV C S : 1 + 0 9 . 7 5 BV C E : 3 6 4 . 6 1 EV C S : 1 + 8 9 . 7 5 EV C E : 3 6 5 . 7 3 LO W P T : 1 + 3 3 . 2 8 EL E V : 3 6 4 . 3 7 PROPOSED WATER MAIN STA: 11+79.13, 19.15 L IE: 358.29 12" (S) IE: 355.15 12" (W) IE: 355.15 12" (E) RIM: 364.46 CB#22, 48" TYPE 2 STA: 1+34.09, 10.39 R IE: 355.68 12" (N) IE: 355.68 12" (W) IE: 355.68 8" (S) RIM: 364.13 CB#23, 48" TYPE 2 STA: 1+00.00 ELEV: 364.52 INTERSECTION JACKSON ST SE 66 LF 12" CPEP @ 3.24%53 LF 12" CPEP @ 1.00% 2-INCH SEWER FM STA: 2+84.45 ELEV: 370.25 END ROAD IMPROVEMENTS 51 50 49 108 106 105 53 54 42 41 46 47 97 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 52 3 100 99 103 98 4 40 s sss s s s s s s ssss s ss s s s s s s s s s s s s CB#2 3 6 4 3 6 2 360 358 356 354 3 5 6 3 5 8 35 2 35 4 3 5 6 3 5 4 360 362364 3 6 4 362 3 6 4 3 5 0 3 6 0 3 5 2 3 5 4 3 5 6 3 5 8 CB#24 CB#23 CB#22 CB#33 CB#36 CB#37 CB#38 CB#26 CB#25 CB#27 CB#32 CB#35 CB#34 STA: 7+06.91 ROAD 2= STA: 14+37.61 JACKSON STA: 1+00 ROAD 1= STA: 11+82.47 JACKSON 2+0 0 3+0 0 4+00 5+00 6+00 7+00 STA: 1+00 BERRY VALLEY= STA: 16+06.86 JACKSON 35 6 358 92 84 91 89 88 87 85 86 90 s s s s s s s s s ss s s s s 3 5 8 35 8 356 354 36 6 36 4 36 2 36 0 358 3 6 8 3 6 4 358 35 2 354 36 0 35 8 36 2 STA: 2+75.47 ROAD 3= STA: 5+15.77 BERRY VALLEY CB#3 CB#4 CB#5 36 0 36 2 3 6 4 3 6 6 2+00 4+ 0 0 5+ 0 0 6+ 0 0 337 340 345 350 355 360 365 370 337 340 345 350 355 360 365 370 0+50 35 0 . 9 7 1+00 35 1 . 2 2 35 1 . 4 7 1+50 35 1 . 7 2 35 1 . 9 7 2+00 35 2 . 2 2 35 2 . 4 7 2+50 35 2 . 7 2 35 2 . 9 7 3+00 35 3 . 2 2 35 3 . 4 7 3+50 35 3 . 7 2 35 4 . 0 0 4+00 35 4 . 3 5 35 4 . 7 5 4+50 35 5 . 2 2 35 5 . 7 2 5+00 35 6 . 2 2 35 6 . 7 2 5+50 35 7 . 2 2 35 7 . 7 2 6+00 35 8 . 2 2 35 8 . 7 2 6+50 35 9 . 2 2 35 9 . 7 2 7+00 36 0 . 2 2 7+50 2-INCH SEWER FM 1.00% 2.00% PVI: 354.22 PVI STA: 4+00.00 K: 100.00 100' VC BV C S : 3 + 5 0 . 0 0 BV C E : 3 5 3 . 7 2 EV C S : 4 + 5 0 . 0 0 EV C E : 3 5 5 . 2 2 PROPOSED WATER MAIN STA: 0+65.06, 17.99 L IE: 348.30 12" (NE) IE: 348.30 12" (SE) RIM: 350.43 CB#33, CB TYPE 1 CB#32, CB TYPE 1 STA 0+67.84, 18.16R RIM: 350.45 IE: 348.48 12" (NW) STA: 1+61.37, 17.89 L IE: 345.63 12" (SW) IE: 345.63 12" (NE) IE: 347.92 12" (SE) IE: 346.13 8" (NW) RIM: 351.45 CB#34, 48" TYPE 2 CB#35, 48" TYPE 2 STA 1+61.37, 17.89R RIM: 351.45 IE: 348.28 12" (NW) IE: 348.28 8" (SE) STA: 3+66.05, 17.89 L IE: 344.59 12" (SW) IE: 344.59 12" (E) IE: 345.09 8" (NW) RIM: 353.51 CB#36, 48" TYPE 2 CB STA: 4+56.52, 18.72 R IE: 348.31 12" (N) IE: 348.31 8" (S) RIM: 354.89 CB#38, CB TYPE 1 CB#37, 48" TYPE 2 CB STA 4+56.52, 17.87L RIM: 354.97 IE: 344.10 12" (W) IE: 344.10 12" (E) IE: 344.10 12" (S) IE: 344.60 8" (N) CB#27, CB TYPE 1 STA 14+60.96, 18.72' R RIM: 358.97 IE: 354.10 12" (W) IE: 354.60 8" (E) CB#25, CB TYPE 1 STA 14+26.38, 21.74' L RIM: 359.94 IE: 353.10 12" (N) STA: 14+60.83, 21.54 L IE: 342.96 12" (W) IE: 342.96 12" (E) IE: 342.96 12" (N) IE: 342.96 12" (S) RIM: 358.68 CB#26, 48" TYPE 2 CB STA: 0+75.00 ELEV: 350.97 CENTER CDS STA: 7+06.91 ELEV: 360.36 INTERSECTION JACKSON ST SE 36 LF 12" DI CL52 @ 0.50% 36 LF 12" CPEP @ 1.00% 37 LF 12" CPEP @ 11.50% 34 LF 12" CPEP @ 29.43% 90 LF 1 2 " D I C L 5 2 @ 2.9 5 % 208 LF 12" CPEP @ 0.50%98 LF 12" CPEP @ 0.50%228 LF 12" CPEP @ 0.50% 40 LF 12" CPEP @ 27.67% 343 345 350 355 360 365 370 375 343 345 350 355 360 365 370 375 0+50 1+00 36 4 . 6 9 36 3 . 1 9 1+50 36 1 . 6 9 36 0 . 1 9 2+00 35 8 . 7 7 35 7 . 9 4 2+50 35 7 . 7 7 35 8 . 1 9 3+00 2-INCH SEWER FM 2.00% 6. 0 0 % PVI: 357.19 PVI STA: 2+25.00 K: 9.38 75' VC BV C S : 1 + 8 7 . 5 0 BV C E : 3 5 9 . 4 4 EV C S : 2 + 6 2 . 5 0 EV C E : 3 5 7 . 9 4 LO W P T : 2 + 4 3 . 7 5 EL E V : 3 5 7 . 7 5 PROPOSED WATER MAIN STA: 2+43.75, 15.50' R IE: 353.58 12" (W) IE: 353.58 12" (NE) RIM: 357.32 CB#4, CB TYPE 1 STA: 2+43.75, 15.50' L IE: 353.89 12" (E) IE: 354.39 8" (SW) RIM: 357.95 CB#3, CB TYPE 1 STA: 1+00.00 ELEV: 364.69 CENTER CDS STA: 2+75.00 ELEV: 358.19 INTERSECTION BERRY VALLEY ROAD SE 31 LF 12" CPEP @ 1.00%35 LF 12" CPEP @ 3.34% STA: 5+61.77, 14.92 R IE: 352.42 12" (SW) IE: 352.42 12" (E) RIM: 356.64 CB#5, CB TYPE 1 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.8 18 ROAD 1, ROAD 2 & ROAD 3 PLAN & PROFILE ROAD 1 PROFILE HORIZ. 1"=50', VERT. 1"=5' EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD SEE C3.7 SEE C3.7 SEE C3.7 ROAD 3 J A C K S O N N ROAD 3 - LOCAL ACCESS RESIDENTIAL 1"=50' ROAD 1 - LOCAL ACCESS RESIDENTIAL 1"=50' SEE C3.4 SEE C3.4 ROAD 2 - LOCAL ACCESS RESIDENTIAL 1"=50' SEE C3.7 ROAD 2 PROFILE HORIZ. 1"=50', VERT. 1"=5' ROAD 3 PROFILE HORIZ. 1"=50', VERT. 1"=5' EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD BE R R Y V A L L E Y J A C K S O N ROAD 2 ROAD 1 N D C3.10 D C3.10 D C3.10 GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 PROPOSED GRADE @ CL OF ROAD 56' ROW 10' UTILITY EASEMENT (TYP.) 10' UTILITY EASEMENT (TYP.) 10' UTILITY EASEMENT (TYP.) 56' ROW 10' UTILITY EASEMENT (TYP.) 10' UTILITY EASEMENT (TYP.) 56' ROW 10' UTILITY EASEMENT (TYP.) 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.9 19 ROAD SECTIONS 0.25' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE 2%2%2%2% 56' RIGHT OF WAY CEMENT CONCRETE SIDEWALK PER YELM DWG. NO. 2-11 RO W RO W 28' RIGHT OF WAY 16' FL O W L I N E 7' LANDSCAPE 5' SIDEWALK CL PROFILE GRADE 2%2% 16' FL O W L I N E 7' LANDSCAPE 5' SIDEWALK 28' RIGHT OF WAY CEMENT CONCRETE BARRIER CURB AND GUTTER PER YELM DETAIL 2-13 2% CL PROFILE GRADE2% 16' FL O W L I N E 5.5' SIDEWALK 2% 2% 16' FL O W L I N E 5.5' END OF ARCH CULVERT RETAINING/ HEADWALL APPROX. 6FT HEIGHT SIDEWALK A NOT TO SCALE BERRY VALLEY ROAD (STA 1+50 TO 13+09 NEIGHBORHOOD COLLECTOR) B NOT TO SCALE BERRY VALLEY ROAD NARROWED SECTION AT THOMPSON CREEK (STA 13+52 TO 14+43 NEIGHBORHOOD COLLECTOR) C NOT TO SCALE BERRY VALLEY ROAD - OFFSITE (STA 14+43 TO 17+87 NEIGHBORHOOD COLLECTOR) 2% VARIES 16'-10' (STA 14+43 TO15+17) 10' (STA 15+17 TO 17+87) CL PROFILE GRADE 2%2% 16' FL O W L I N E 7' LANDSCAPE 5' SIDEWALK 2:1 MAX TO MATCH EXISTING GRADE 2:1 MAX TO MATCH EXISTING GRADE STORM SYSTEM AS REQUIRED VARIES 3.2-3.3' EX R O A D CL & C R O W N EX I S T I N G R O W VARIES 19.7'-19.8' VARIES 26.8'-27.4' EX I S T I N G R O W PR O P O S E D R O W ROW DEDICATION 0.7'-1.1' EXISTING ROAD PAVEMENT 9.0' EXISTING ROAD PAVEMENT 9.0' VARIES ~2.2' EX R O A D CL & C R O W N EXISTING ROAD PAVEMENT VARIES > 9.5' EXISTING ROAD PAVEMENT 8.8' EX I S T I N G R O W VARIES > 20.3' VARIES >31' PR O P O S E D R O W 23' 5' PR O P O S E D R O W 28' 2' SHOULDER 0.25' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE 10' DRY UTILITY EASEMENT 2' STORM EASEMENT 10' DRY UTILITY EASEMENT 2' STORM EASEMENT CONSTRUCTION / ROAD CENTERLINE CONSTRUCTION / ROAD CENTERLINE CONSTRUCTION / ROAD CENTERLINE CEMENT CONCRETE SIDEWALK PER YELM DWG. NO. 2-11 CEMENT CONCRETE BARRIER CURB AND GUTTER PER YELM DETAIL 2-13 3:1 SLOPE 0.50' GRAVEL PROPOSED 8" WATER, 3.5' TYP. COVER 3. 5 ' PROPOSED 8" WATER, 3.5' TYP. COVER 3. 5 ' PROPOSED 8" WATER 11.00' PROPOSED SEWER FORCEMAIN, SIZE VARIES 5.5' TYP. COVER 5. 5 ' 11.00' 1 NOT TO SCALE HAND RAILING PEDESTRIAN RAILING WHERE WALL HEIGHT EXCEEDS 30" 1 C3.9 1.0', MIN 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-ROAD&PROF.dwg C3.10 20 ROAD SECTIONS 2% 2%2%2% 2% 56' RIGHT OF WAY CL O F R O W CEMENT CONCRETE SIDEWALK PER YELM DWG. NO. 2-11 CEMENT CONCRETE ROLLED CURB AND GUTTER PER YELM DWG. NO. 2-13 RO W RO W 30.5' RIGHT OF WAY25.5' RIGHT OF WAY 2.5' 18.5' FL O W L I N E 1' BA C K O F C U R B 6' LANDSCAPE 5' SIDEWALK 18.5' FL O W L I N E 1' BA C K O F C U R B 6' LANDSCAPE CL PROFILE GRADE D NOT TO SCALE ROAD 1 - 3 & JACKSON STREET (LOCAL ACCESS RESIDENTIAL) 10' DRY UTILITY EASEMENT 2' STORM EASEMENT 10' DRY UTILITY EASEMENT 2' STORM EASEMENT CONSTRUCTION / ROAD CENTERLINE 0.25' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE PROPOSED 8" WATER, 3.5' TYP. COVER 3. 5 ' 11.00' PROPOSED SEWER FORCEMAIN, SIZE VARIES 5.5' TYP. COVER 5. 5 ' 11.00' 10/09/2024 S3° 21' 19"E 49.73' CB#39 CB TYPE 1 RIM: 329.21 IE: 327.21 12" (N) CB#40 CB TYPE 1 RIM: 329.21 IE: 327.06 12" (S) IE: 327.06 12" (E) 30 LF 12" DI @ 0.50% 25 7 L F 1 2 " D I @ 0 . 5 8 % 33 0 33 0 33 0 3 2 8 BE R R Y V A L L E Y R D S E 10+00 10+50 11+00 11+50 11+75 51.00' R.O.W. 3 C3.11 ST A : 1 0 + 3 5 . 0 0 ST A : 1 0 + 6 5 . 9 8 0 0 ST A : 1 0 + 7 5 . 0 0 ST A : 1 1 + 2 0 . 4 4 0 0 S T A : 1 1 + 4 0 . 0 0 S T A : 1 1 + 6 5 . 8 6 3 2 7 3 2 8 3 2 9 32 9 3 3 0 330 32 9 14 + 0 0 14 + 5 0 15 + 0 0 PT: 14+06.13 FG: 323.68 FG: 323.33 FG: 323.70 FG: 323.73 FG: 323.69 FG: 323.49 FG: 324.43 FG: 323.56 FG: 323.91 FG: 324.13 PROPOSED ARCH PIPE BOX CULVERT, SEE SHEET C3.12 FOR MORE INFORMATION NO SLOPE CREEK FG: 324.6 OHWM FG: 324.6 OHWM FG: 324.3 OHWM FG: 324.3 OHWM FG: 324.8 OHWM FG: 324.8 OHWM EDGE OF WETLAND EDGE OF WETLAND FG: 324.3 OHWM 316 320 325 330 335 316 320 325 330 335 10+00 10+50 32 9 . 8 6 11+00 32 9 . 7 1 11+50 38 LF 24" EXST. CONC. @ - -0.56% EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE AT CULVERT CENTERLINE EXISTING GRADE AT SECTION LINE APPROX. 6' TALL HEADWALL 3:1 1. 7 1 ' EXISTING ROW / PROPERTY LINE PROPOSED 8" WATER ROW BE R R Y V A L L E Y R D S E CE N T E R L I N E 55 LF 8'-9" SPAN x 2-6" RISE CULVERT @ 0.00% PROPOSED GRADE ELEVATION AT SECTION LINE STA: 10+57.88 SCALE: H:20, V:2 316 320 324 328 332 336 316 320 324 328 332 336 0 10 200-10-20 STA: 10+75.00 SCALE: H:20, V:2 316 320 324 328 332 336 316 320 324 328 332 336 0 10 200-10-20 STA: 10+35.00 SCALE: H:20, V:2 312 316 320 324 328 332 336 312 316 320 324 328 332 336 0 10 200-10-20 STA: 11+20.44 SCALE: H:20, V:2 312 316 320 324 328 332 336 312 316 320 324 328 332 336 0 10 200-10-20 STA: 11+40.00 SCALE: H:20, V:2 312 316 320 324 328 332 336 312 316 320 324 328 332 336 0 10 200-10-20 STA: 11+65.86 SCALE: H:20, V:2 316 320 324 328 332 336 316 320 324 328 332 336 0 10 200-10-20 EXISTING GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED CULVERT PROPOSED CULVERT 319 320 325 330 335 340 319 320 325 330 335 340 13+50 33 0 . 2 5 33 0 . 0 6 14+00 32 9 . 8 8 32 9 . 6 9 14+50 32 9 . 5 1 14+75 32 9 . 3 2 0.74% EXISTING 24" PIPE TO BE REMOVED PROPOSED GRADE AT ROAD CENTERLINE ELEV: 324.14 1.50' MIN COVER EXISTING 24" PIPE TO BE REMOVED INSTALL 16" STEEL CASING CULVERT FOOTING 3 C3.12 PROPOSED ARCH PIPE BOX CULVERT, SEE SHEET C3.12 FOR MORE INFORMATION N GRAPHIC SCALE 0 20 40 FEET 1" = 20 FEET 10 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-CREEK.dwg C3.11 21 THOMPSON CREEK CROSS SECTIONS 3 SCALE: H:1" = 20', V:1" = 5' THOMPSON CREEK CULVERT PROFILE1SCALE: H:1" = 20', V:1" = 2' THOMPSON CREEK CROSS SECTIONS 2 SCALE: H:1" = 20', V:1" = 5' CULVERT CROSS SECTION CULVERT FOOTING SECTION AT CULVERT OUTLET SECTION AT CULVERT OUTLET OHWM ELEV: 324.3 OHWM ELEV: 324.6OHWM ELEV: 324.6 OHWM ELEV: 324.1 OHWM ELEV: 324.3 OHWM ELEV: 324.3 OHWM ELEV: 324.8 OHWM ELEV: 324.6 THOMPSON CREEK CULVERT CROSSING. REFER TO SEPARATE HPA PERMIT FOR ADDITIONAL REQUIREMENTS. 10/09/2024 INSIDE STRUCTURE FG INSIDE CULVERT INSIDE STRUCTURE FG INSIDE CULVERT 4" MIN. 8" WATER MAIN CROSSING NOTES: 1.) SCOUR POTENTIAL HAS NOT BEEN ADDRESSED IN THIS DESIGN. 2.) THE ALLOWABLE BEARING CAPACITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION BY A COMPETENT GEOTECHNICAL ENGINEER. ALLOWABLE BEARING CAPACITY = 4,000 psf HEIGHT OF COVER = 1.4 TO 2.5 ft 2" 2" 10" 10" 2' 2' 4" 4" SPREAD FOOTING SPREAD FOOTING WORKING POINT SPAN (8'-5") 8'-9" SPAN WORKING POINT SPAN (8'-5") 8'-9" SPAN NON-METALIC, NON-SHRINK GROUT OR 4,000 PSI FIBER-REINFORCED CONCRETE W/ SMALL AGGREGATE NON-METALIC, NON-SHRINK GROUT OR 4,000 PSI FIBER-REINFORCED CONCRETE W/ SMALL AGGREGATE SUPPORT FOR CARRIER PIPE INSIDE CASING PER DETAIL 2' MIN. 2' MIN. 70.03° 7 1 4" APPROXIMATE AREA = 18.4 SQ. FT. 8'-9" 2'-6" REINFORCING RIB R24'-9 1 2" R2'-6 14" FG INSIDE CULVERT 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-CREEK.dwg C3.12 22 THOMPSON CREEK CROSSING DETAILS STEEL CASING PIPE 1 NOT TO SCALE OPEN BOTTOM BOX CULVERT DETAIL 2 NOT TO SCALE CULVERT FOOTING DETAIL 3 NOT TO SCALE SUPPORT FOR CARRIER PIPE INSIDE CASING 10/09/2024 350 349 35 1 35 2 353 354 350 35 3 1+00 1+50 PI : 1 + 0 0 . 0 0 15 + 5 0 16 + 0 0 16 + 5 0 PROVIDE STOP / STREET SIGN STA:1+44.72, 19.90' LT BERRY VALLEY ROAD SE JA C K S O N S T . S E BCR STA: 1+51.00, 16.00' LT FL: 349.82 BCR STA: 1+46.00, 16.00' RT FL: 349.84 3 5 1 352 3 5 3 3543 5 4 354 350 34 9 351 352 353 CB#2 RIM: 349.84CB#27 RIM: 352.39 CB#1 RIM: 349.84 1.74 % 1. 7 0 % 5.0' 5.0' 5.0' 5.0' FL: 353.38 FL: 353.46 FL: 353.59 FL: 353.68 FL: 351.42 FL: 351.51 FL: 349.21 FL: 349.13 FL: 349.20 FL: 349.13 1/2 Δ FL: 349.17 1/2 Δ FL: 351.84 FG: 353.11 FG: 353.20 FG: 352.01 FG: 351.92 FG: 353.88 FG: 353.95 FG: 349.62 FG: 349.70 FG: 349.63 FG: 349.71 7 . 5 0 % 7.50% 1. 5 0 % 7.5 0 % 7.50% 7.50% 5.0' 1. 5 0 % 6.5' 6.5' 1.0' 5.0' 6.5' FG: 350.42 FG: 350.32 FG: 349.81 FG: 349.73 FG: 349.41 FG: 349.31 2.0 0 % 2.0 0 % 7. 6 2 % 5 . 3 3 % 2.00% 2.0 0 % 1 . 6 1 % 6.2' 9.0' 2.00% 3. 6 8 % 7. 9 4 % 2.00% 2.00% 1. 5 0 % FG: 349.49 FG: 349.39 FG: 349.72 FG: 349.80 FG: 350.51 FG: 350.41 35 0 349 3 5 1 3 5 2 3 5 3 1.74 % 7.7 2 % 1. 8 8 % 1.00% 1.00% 0 . 5 0 % 0 . 5 0 % 9.31% FG: 351.95 FG: 352.03 FG: 350.45 FG: 350.55 FG: 353.25 FG: 353.16 2. 0 0 % 5.0' 15.0' 14.6'6.0' 12.0' 5. 4 9 % 2.00% 1. 5 0 % 8. 0 1 % 2.00% 2.00% FG: 353.65 FG: 353.55 FG: 353.98 FG: 354.05 FG: 355.02 FG: 354.92 S88° 41' 33"E 608.73' PROVIDE MONUMENT JACKSON STA:15+48.35, 0.00' PROVIDE MONUMENT JACKSON STA: 16+06.86 = BERRY VALLEY STA: 0+99.99 ECR STA: 16+57.86, 16.00' RT FL: 348.04 ECR STA: 15+55.86, 11.00' RT FL: 353.75 10.0' UTILITY EASEMENT TC: 354.25 TC: 354.18 ROW 1 1 1 1 1 2 2 2 22 2 2 2 2 2 2 2 2 R25.00' R25.00' 55 56 57 59 97 CONSTRUCTION CENTERLINE Δ=90°00'00" R=35.00' L=54.98' Δ=90°00'00" R=35.00' L=54.98' 35 7 358 358 4+50 5+00 5+50 2+ 5 0 3+ 0 0 3+ 0 0 PROVIDE MONUMENT BERRY VALLEY STA: 5+15.77 = ROAD 3 STA: 2+75.47 BERRY VALLEY ROAD SE RO A D 3 35 735 8 359 359 ECR STA: 4+69.77, 16.00' RT FL: 358.39 ECR STA: 5+61.77, 16.00' RT FL: 356.62 BCR STA: 2+24.47, 11.00' LT FL: 357.67 BCR STA: 2+24.47, 11.00' RT FL: 357.67 CB#3 RIM: 357.95 CB#4 RIM: 357.32 CB#5 RIM: 356.64 4.0' 7.5' 7 . 5 0 % 1.5 0 % 7.78 % 9.7 0 % 5.0' 5.0' 2. 0 0 % 1 . 3 2 % 7.84% 6.5' 5.0' FL: 358.09 FL: 358.01 TC:357.17 FL: 357.17 TC:357.11 FL: 357.11 TC:357.81 FL: 357.31 TC:357.51 FL: 357.01 FL: 357.29FL: 357.37 1/2 Δ FL: 358.03 1/2 Δ FL: 357.14 FG: 359.00 FG: 359.10 FG: 357.68 FG: 357.74 FG: 357.85 FG: 357.51 FG: 357.43 FG: 357.63 2. 0 0 % 1.50% 5.0' 2.00% 0.54% 2. 0 0 % BC: 358.24 BC: 358.14 11.0'TC: 358.81 TC: 358.74 6.5' 9.0'6.0'5.0' 2. 0 0 % 2. 0 0 % 2. 0 0 % FG: 358.34 FG: 357.61 FG: 357.53 FG: 357.84 FG: 358.24 FG: 357.74 8.14%1.50%5.13% 3 5 7 358 S88° 41' 33"E 608.73'S88° 41' 33"E 608.73' N1 ° 1 8 ' 2 7 " E 17 5 . 4 7 ' CONSTRUCTION CENTERLINE 10.0' UTILITY EASEMENT 1 1 FG: 357.82 FG: 357.76 1.5 0 % 2 . 0 0 % 1 2 2 1 2 2 ROW ROLLED CURB TRANSITION TC: 357.98 TC: 358.17 TC: 358.17 TC: 357.98 R25.00'R25.00' 66 67 68 8591 Δ=90°00'00" R=35.00' L=54.98' Δ=90°00'00" R=35.00' L=54.98' ABBREVIATIONS STA STATION EG EXISTING GRADE FG FINISH GRADE FL FLOW LINE TC TOP OF CURB BC BOTTOM OF CURB LT LEFT RT RIGHT BCR BEGIN CURB RADIUS ECR END CURB RADIUS L LENGTH R RADIUS HP HIGH POINT LP LOW POINT KEYNOTES ADA RAMP LANDING. SLOPE NOT TO EXCEED 2% IN ANY DIRECTION. ADA RAMP. SLOPE SHALL NOT EXCEED 8.3% IN DIRECTION OF TRAVEL UNLESS APPLYING 15-FOOT MAXIMUM LENGTH. CROSS SLOPES SHALL NOT EXCEED 2%. 1 2 N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 10, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-INTX.dwg C4.1 23 INTERSECTION DETAILS 2 SCALE: 1" = 10' BERRY VALLEY RD SE & JACKSON ST SE INTERSECTION 3 SCALE: 1" = 10' BERRY VALLEY RD SE & ROAD 3 INTERSECTION 5' 5.0' 6' 8' ROLLED CURB TRANSITION CEMENT CONCRETE BARRIER CURB AND GUTTER TA P E R M A I N T A I N E D G E O F C O N C R E T E C U R B CEMENT CONCRETE ROLLED CURB & GUTTER 3' H A N D TR O W E L L E D SE C T I O N 1 NOT TO SCALE CURB TRANSITION DETAIL 1 C4.1 1 C4.1 N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 10/09/2024 3 6 5 36 5 3 6 2 3 6 3 3 6 4 11 + 5 0 1 2 + 0 0 0+50 1+00 PROVIDE STOP / STREET SIGN STA:1+34.14, 15.32' LT ROAD 1 J A C K S O N S T . S E 3 6 5 36 5 CB#22 RIM: 364.13 CB#23 RIM: 364.13 CB#21 RIM: 364.46 FL: 364.50 FL: 364.55 FL: 364.44 FL: 364.34 1/2 Δ FL: 364.24 1/2 Δ FL: 364.09 TC: 364.23 TC: 364.23 FG: 364.02 FG: 364.12 FG: 364.85 FG: 364.88 5.0' 1.99% 1 . 0 5 % BC: 363.69 BC: 363.64 7.10% 2 . 0 0 % 11.58% 14.73% 5.0' 6.0' 1.00' 5.00' 6.00' N83° 40' 08"E 184.29' L=230.02' R =2 2 7.5 0' Δ=57°5 5'5 3" L = 2 3 0 . 0 2 ' R = 2 2 7 . 5 0 ' Δ = 5 7 ° 5 5 ' 5 3 " N 6 ° 1 9 ' 5 2 " W 2 9 7 . 0 5 ' 1.99%FG: 364.98 FG: 364.95 PROVIDE MONUMENT JACKSON STA:12+19.22, 0.00' ECR STA: 11+76.31, 31.01' RT FL: 364.08 ECR STA: 12+18.70, 11.00' RT FL: 364.72 BCR STA: 11+96.12, 36.59' RT FL: 364.10 BCR STA: 11+54.95, 11.00' RT FL: 364.09 PROVIDE MONUMENT JACKSON STA: 11+82.47 = ROAD 1 STA: 1+00.00 CONSTRUCTION CENTERLINE 1 . 9 7 % 10.0' UTILITY EASEMENT 5.0' 1 1 2 2 0 . 4 2 % ROW R25.00' 3 4 TRACT L TRACT F Δ=90°00'00" R=25.00' L=39.27' R25.00' R197.00' Δ=75°47'28" R=25.00' L=33.07' 10.0' UTILITY EASEMENT 360 358 359 36 1 1 4 + 0 0 1 4 + 5 0 6+50 7+00 7+507+50 PROVIDE STOP / STREET SIGN STA:6+72.98, 15.13' RT J A C K S O N S T . S E ROAD 2 361 359 3 5 9 357 358 359 N 6 ° 1 9 ' 5 2 " W 2 9 7 . 0 5 ' CB#25 RIM: 358.68 CB#24 RIM: 359.94 CB#26 RIM: 358.97 1/2 Δ FL: 358.69 1/2 Δ FL: 360.21 BC: 359.77 BC: 359.74 TC: 360.15 TC: 360.27 FG: 361.39 FG: 361.49 FL: 359.62 FL: 359.70 FL: 358.78 FG: 359.03 FG: 358.93 TC: 359.06 TC: 359.13 2 . 4 9 % 2.00% 2.00% 1 . 0 1 % 1 . 5 0 % 6.0' 5.0' 5.0' 15.0' 2.00% 1 1 . 4 7 % 1 . 9 3 % 0 . 7 4 % 0.50% BC: 358.88 BC: 358.78 1.50% S88° 41' 33"E 221.61' N 6 ° 1 9 ' 5 2 " W 2 9 7 . 0 5 ' ECR STA: 14+79.43, 16.00' LT FL: 358.16 ECR STA: 14+54.65, 44.32' LT FL: 359.15 BCR STA: 14+30.89, 32.68' LT FL: 359.45 ECR STA: 14+06.12, 11.00' LT FL: 360.98 PROVIDE MONUMENT JACKSON STA: 14+37.61 = ROAD 2 STA: 7+06.91CONSTRUCTION CENTERLINE CONSTRUCTION CENTERLINE 10.0' UTILITY EASEMENT TC: 359.34 TC: 359.65 1 1 6.0' 2 2 6.0' ROW R25.00' R25.00'98 99 100 101 104 55 Δ=97°38'19" R=25.00' L=42.60' Δ=82°21'41" R=25.00' L=35.94' ABBREVIATIONS STA STATION EG EXISTING GRADE FG FINISH GRADE FL FLOW LINE TC TOP OF CURB BC BOTTOM OF CURB LT LEFT RT RIGHT BCR BEGIN CURB RADIUS ECR END CURB RADIUS L LENGTH R RADIUS HP HIGH POINT LP LOW POINT KEYNOTES ADA RAMP LANDING. SLOPE NOT TO EXCEED 2% IN ANY DIRECTION. ADA RAMP. SLOPE SHALL NOT EXCEED 8.3% IN DIRECTION OF TRAVEL UNLESS APPLYING 15-FOOT MAXIMUM LENGTH. CROSS SLOPES SHALL NOT EXCEED 2%. 1 2 N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 10, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-INTX.dwg C4.2 24 INTERSECTION DETAILS 1 SCALE: 1" = 10' JACKSON ST SE & ROAD 2 INTERSECTION 2 SCALE: 1" = 10' JACKSON ST SE & ROAD 1 INTERSECTION ROLLED CURB TRANSITION 1 C4.1 N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 10/09/2024 362 363 364 0+ 5 0 1+ 0 0 1+ 5 0 RO A D 3 BCR STA: 1+43.05, 18.50' LT FL: 361.67 ECR, BCR STA: 1+25.96, 25.25' LT FL: 362.60 ECR, BCR STA: 1+28.85, 27.23' RT FL: 362.39 ECR STA: 1+47.83, 18.50' RT FL: 361.39 365 366 36 7 365 365 366 366 366 367 368 STA: 1+00.00, 0.00' FG: 364.69 360 3 5 6 3 5 7 358359 360 361 1/2 Δ FL: 366.61 3/4 Δ FL: 364.501/4 Δ FL: 364.83 7/8 Δ FL: 363.451/8 Δ FL: 363.72 3/8 Δ FL: 365.94 5/8 Δ FL: 365.55 10.0' UTILITY EASEMENT 5.0'6.0' N1 ° 1 8 ' 2 7 " E 50 . 0 0 ' N1 ° 1 8 ' 2 7 " E 17 5 . 4 7 ' R25.00' ROW R25.00' 86 87 88 89 90 Δ=43°06'01" R=25.00' L=18.81' Δ=49°23'55" R=25.00' L=21.55' Δ=272°29'56" R=38.00' L=180.73' CONSTRUCTION CENTERLINE CENTER OF CUL-DE-SAC STA:1+00.00, 2.50' RT 0+50 1+00 1+5 0 ROAD 2 3 5 0 3 5 1 35 1 351 351 351 35 2 BCR STA: 1+54.48, 18.50' LT FL: 351.33 ECR, BCR STA: 1+29.83, 28.80' LT FL: 350.86 ECR, BCR STA: 1+25.66, 24.27' RT FL: 350.92 BCR STA: 1+39.36, 18.50' RT FL: 351.18 STA: 1+61.37, 0.00' FG: 351.84 L =6 1 .3 7 'R =2 0 2 .5 0 ' Δ =1 7 °2 1 '4 8 " N63° 1 4 ' 2 5 " E 50.00 ' N45 ° 5 2 ' 3 7 " E 167 . 3 4 ' STA: 1+00.00, 0.00' FG: 351.22 3 5 0 3 4 7 3 4 8 3 4 9 CB#32 RIM: 350.43 CB#31 RIM: 350.45 CB#35 RIM: 351.45 CB#33 RIM: 351.45 1/2 Δ FL: 350.76 3/4 Δ FL: 350.64 1/4 Δ FL: 350.61 7/8 Δ FL: 350.78 1/8 Δ FL: 350.74 3/8 Δ FL: 350.48 5/8 Δ FL: 350.50 10.0' UTILITY EASEMENT ROW R50.00' R25.00' R25.00' 43 44 45 TRACT H CONSTRUCTION CENTERLINE Δ=271°05'24" R=38.00' L=179.79' Δ=57°32'54" R=25.00' L=25.11' Δ=37°49'12" R=25.00' L=16.50' CENTER OF CUL-DE-SAC STA:1+00.00, 2.50' LT ABBREVIATIONS STA STATION EG EXISTING GRADE FG FINISH GRADE FL FLOW LINE TC TOP OF CURB BC BOTTOM OF CURB LT LEFT RT RIGHT BCR BEGIN CURB RADIUS ECR END CURB RADIUS L LENGTH R RADIUS HP HIGH POINT LP LOW POINT N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 10, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-INTX.dwg C4.3 25 INTERSECTION DETAILS 1 SCALE: 1" = 10' ROAD 3 CUL-DE-SAC 2 SCALE: 1" = 10' ROAD 2 CUL-DE-SAC 5.0'6.0' R50.00' N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 10/09/2024 DATE: September 10, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-INTX.dwg C4.4 26 PUBLIC ROAD NOTES & DETAILS 4"1.0' SEE NOTE 1 GENERAL NOTES 1.MATERIALS AND CONSTRUCTION REQUIREMENTS SHALL BE PER LATEST EDITION OF WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION UNLESS OTHERWISE NOTED. PL 6' MIN FROM PL DRIVEWAY PORTION OF SIDEWALK TO BE 6" THICK 6' 20' MAX. 5' SIDEWALK PER CITY OF YELM DWG NO. 2-11 BACK OF CURB 6" THICK CEMENT CONCRETE DRIVEWAY 2%2% 2% 4" CONCRETE (6" @ DRIVEWAY LOCATIONS) CEMENT CONCRETE ROLLED CURB AND GUTTER 5' SIDEWALK 6' LANDSCAPE 1.SEE CITY OF YELM DWG. NO 2-11 FOR ADDITIONAL NOTES & DETAILS 2.MINIMUM CONCRETE DEPTH OF 6" IS REQUIRED AT ALL PROPOSED DRIVEWAY LOCATIONS NOTES 1.DRIVEWAY LOCATIONS TO BE IDENTIFIED BY THE CONTRACTOR PRIOR TO POURING THE SIDEWALKS OR ALL SIDEWALKS SHALL BE 6" THICK. NOTES 1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS, AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL IN ACCORDANCE WITH MUTCD. PRIOR TO DISRUPTION OF ANY TRAFFIC, TRAFFIC CONTROL PLANS SHALL BE PREPARED AND SUBMITTED TO THE CITY FOR APPROVAL. NO WORK SHALL COMMENCE UNTIL ALL APPROVED TRAFFIC CONTROL IS IN PLACE. 3.ALL CURB AND GUTTER, STREET GRADES, SIDEWALK GRADES, AND ANY OTHER VERTICAL AND/OR HORIZONTAL ALIGNMENT SHALL BE STAKED BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK. 4.WHERE NEW ASPHALT JOINS EXISTING, THE EXISTING ASPHALT SHALL BE CUT TO A NEAT VERTICAL EDGE AND TACKED WITH ASPHALT EMULSION TYPE CSS-1 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. THE NEW ASPHALT SHALL BE FEATHERED BACK OVER EXISTING TO PROVIDE FOR A SEAL AT THE SAW CUT LOCATION AND THE JOINT SEALED WITH GRADE AR-4000W PAVING ASPHALT. 5.COMPACTION OF SUBGRADE, ROCK, AND ASPHALT SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. 6.SUBGRADE INSPECTION SHALL BE PERFORMED BY AN APPROVED TESTING FIRM AND FORMS SHALL BE INSPECTED FOR LINE AND GRADE BY AN ENGINEER BEFORE POURING CONCRETE. 7.CERTIFICATION AS TO CONFORMANCE SHALL BE PROVIDED TO THE CITY PRIOR TO ACCEPTANCE OF WORK. 8.THE CONTRACTOR/DEVELOPER SHALL FURNISH AND INSTALL ALL PERMANENT SIGNING. GENERAL NOTES (STREET CONSTRUCTION) 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX 6 NOT TO SCALE ASPHALT WEDGE CURB 7 NOT TO SCALE SIDEWALK DETAIL 8 NOT TO SCALE DRIVEWAY PLACEMENT 1 NOT TO SCALE ON-STREET PARKING 2 NOT TO SCALE CEMENT CONCRETE SIDEWALK 3 NOT TO SCALE CEMENT CONCRETE CURBS 4 NOT TO SCALE CAST IN PLACE MONUMENT 5 NOT TO SCALE STREET TREE 10/09/2024 6" 5.6' 2.0' 2.6' 1.4' 5.0' SIDEWALK 4.0' MIN DATE: September 10, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-INTX.dwg C4.5 27 PUBLIC ROAD NOTES & DETAILS INSTALLATION REQUIREMENTS SPECIFIED IN USPS STD-4C INCLUDE: 1. AT LEAST ONE CUSTOMER COMPARTMENT SHALL BE POSITIONED LESS THAN 48" FROM THE FINISHED GRADE. 2. NO PARCEL LOCKER (INTERIOR BOTTOM SHELF) SHALL BE POSITIONED LESS THAN 15" FROM FINISHED GRADE. 3. NO PATRON (TENANT) LOCK SHALL BE POSITIONED MORE THAN 67" ABOVE FINISHED GRADE. 4. NO CUSTOMER COMPARTMENT (INTERIOR BOTTOM SHELF) SHALL BE POSITIONED LESS THAN 28" FROM FINISHED GRADE. 5. THE USPS ARROW LOCK SHALL BE POSITIONED 36"-48" ABOVE FINISHED GRADE. 1.19' 16 3 4" 62 3 4" 48 14" 30 12" 6" 18"MOUNT ON PEDESTAL PROVIDED WITH N.D.C.B.U. UNIT 18" CEMENT CONCRETE ROLLED CURB AND GUTTER 6.0' BUFFER CONTRACTOR IS RESPONSIBLE TO VERIFY MAILBOX CLUSTER LOCATIONS WITH USPS PRIOR TO INSTALLATION. CONTACT: JEM ROGERS, (360) 458-4715 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX 1 NOT TO SCALE MAILBOX PLACEMENT 10/09/2024 DATE: September 10, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-INTX.dwg C4.6 27 PUBLIC ROAD NOTES & DETAILS 1 NOT TO SCALE PERMANENT BARRICADE 3 NOT TO SCALE STOP SIGN 2 NOT TO SCALE SIGN SUPPORT 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX 10/09/2024 LEVEL-SPREADER DISPERSAL TRENCH DISCHARGE 34 0 35 0 33 6 33 8 34 2 34 4 34 6 34 8 340 340 334 336 338 342 342 344 344 346 346 33 4 33 4 33 6 33 6 3 4 0 3 4 0 3 3 4 3 3 6 3 3 8 3 4 2 3 4 2 3 4 4 3 4 4 3 4 6 3 4 6 CB#31 RIM: 346.05 N 596246.00 E 1107030.87 IE: 338.31 12" (E) IE: 338.31 12" (NW) CNTRL#1 RIM: 346.84 N 596333.47 E 1106791.05 IE: 338.00 18" (E) IE: 338.00 18" (NW) IE: 335.15 8" (NE) 120 LF 12" CPEP @ 2.50% 66 LF 12" CPEP @ 3.53% 38 LF 18" CPEP @ 6.59% 43 LF 18" CPEP @ 5.14% WEST POND DISPERSAL BASIN RIM: 338.03 IE: 335.80 18" (SE) OUTLET FROM WEST POND IE: 335.50 18" (W) OUTLET TO WEST POND IE: 336.00 12" (SE) 34 0 35 0 342 344 346 34 8 10+ 0 0 10+ 5 0 11+00 11+50 12+00 12+50 13+00 15.0 0 ' A C5.1 20 + 0 0 20 + 5 0 21 + 0 0 21 + 5 0 21 + 8 7 3 4 2 3 4 4 3 4 6 15 . 0 0 ' 15 . 0 0 ' BW: 338.44 EW: 342.94 TW: 342.94 BW: 338.44 TW: 342.94 EW: 342.94 SITE RETAINING WALL TO BE BIDDER DESIGNED EMERGENCY OVERFLOW SPILLWAY 5 C5.5 1 0 . 2 0 ' 1 C5.1 1 C5.5 GRAVEL ACCESS ROAD3 C5.5 R25 . 0 0 ' R 2 5 . 0 0 ' R25.00' R2 6 . 5 0 ' R2 5 . 0 0 ' 6' CHAINLINK FENCE 36 LF 8" 8" CPEP @ 0.98% W POND GRAVITY DRAIN OUTLET IE: 335.50 8" (SW) BW: 338.44 TW: 342.94 330 335 340 345 350 330 335 340 345 350 34 0 . 0 0 10+50 34 6 . 0 1 33 7 . 7 8 11+00 33 4 . 0 0 33 4 . 0 0 11+50 33 4 . 0 0 33 7 . 0 0 12+00 33 3 . 0 0 33 3 . 0 0 12+50 34 0 . 2 4 34 7 . 2 3 2:1 3 : 1 2:1 2 : 1 3:1 BOTTOM OF WETPOND #1 ELEV: 334.00 BOTTOM OF WETPOND #2 ELEV: 333.00EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE ELEVATION AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE 15.00' POND ACCESS ROAD PROPERTY LINE PROPERTY LINE LOT 57 PAD: 347.50 TOP FC STORAGE ELEV: 345.00 WATER QUALITY ELEV: 338.00 TOP SEDIMENT STORAGE BOTTOM WQ ELEV: 334.00 4.0' 1.0' IE: 335.50 38 LF 18" CPEP @ 6.59% 43 LF 18" CPEP @ 5.14% CNTRL#1 RIM: 346.84 IE: 338.00 18" (E) IE: 338.00 18" (NW) IE: 335.15 8" (NE) IE: 336.53 IE: 337.00 66 LF 12" CPEP @ 3.53% TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER INTERNAL BERM ELEV: 337.00 RETAINING WALL BIDDER DESIGNED 3:1 3:1 3 : 1 3.00' GRADING BENCH 4.50'3.00' GRADING BENCH IE: 335.50 4.5' 7.0' 330 335 340 345 350 330 335 340 345 350 34 6 . 0 1 20+50 33 8 . 4 4 33 4 . 0 0 21+00 33 4 . 0 0 33 4 . 3 0 21+50 34 4 . 1 3 33 9 . 3 1 EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE ELEVATION AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE 15.00' POND ACCESS ROAD BOTTOM OF WETPOND #2 ELEV: 334.00 6:1 3 : 1 3 : 1 3:1 2 : 1 BOUNDARY LINE PROPERTY LINE LOT 51 PAD: 344.00 TOP FC STORAGE ELEV: 345.00 WATER QUALITY ELEV: 338.00 4.0' 7.0' 6.00' BERM WIDTH 3:1 RETAINING WALL BIDDER DESIGNED TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER RETAINING WALL BIDDER DESIGNED 3.00' GRADING BENCH 3.00' GRADING BENCH 4.5'4.5' 3.00' GRADING BENCH N GRAPHIC SCALE 0 20 40 FEET 1" = 20 FEET 10 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.1 29 TRACT E STORM POND PLAN & PROFILE A SCALE: H:1" = 20', V:1" = 4' POND SECTION 1 B SCALE: H:1" = 20', V:1" = 4' POND SECTION 2 NOTES: 1.PIPE SUPPORTS AND RESTRICTOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2" IN WALL. 2.THE RESTRICTOR/SEPARATOR SHALL BE FABRICTED FROM .060" ALUMINUM, OR .064" ALUMINIZED STEEL, OR .064" GALVANIZED STEEL PIPE; IN ACCORDANCE WITH AASHTO M 36, M 196, M 197 AND M 274. GALVANIZED STEEL SHALL HAVE TREATMENT 1. 3.OUTLET SHALL BE CONNECTED TO DRAIN PIPE WITH A STANDARD COUPLING BAND FOR CORRUGATED METAL PIPE. 4.THE VERTICAL RISER STEM OF THE RESTICTOR SHALL BE THE SAME DIAMETER AS THE HORIZONTAL OUTLET PIPE. 5.FRAME AND LADDER OR STEPS OFFSET SO THAT: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB.SECTION 18" SD FROM POND18" SD TO DISPERSAL TRENCH IE= 338.00 PIPE SUPPORT(S): 3" x 0.090" TOP OF FLAT SLAB = 346.17 ELEV = 345.00 8.0-INCH NOTCH 4.0-INCH FROM TOP PIPE POLYPROPYLENE-COATED STEEL STEPS OR LADDER. CLEANOUT GATE: SHEAR GATE IE= 338.0 54" DIA. 2. 0 ' 2. 0 ' 1.0' MIN. 18 " M A X . 6" MI N . 12" RISER RESTRICTOR PLAN W/ ONE 1.47" ORIFICE. ORIFICE ELEV = 336.00 RIM = 346.84 PLAN 18 " O U T 18" IN FROM POND T O C O U N T Y S Y S T E M 1 NOT TO SCALE WEST POND CONTROL STRUCTURE (CNTRL#1)TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER 1 C5.7 B C5.1 10/09/2024 J A C K S O N S T . S E 350 352 354 356 358 3 5 8 350 352 354 356 35 8 35 8 35 2 35 4 356 3 5 6 3 5 4 360 352 354 356 358 362 352 354 356 358 CB#22 RIM: 364.46 N 595847.25 E 1107180.82 IE: 358.29 12" (S) IE: 355.15 12" (W) IE: 355.15 12" (E) CB#24 RIM: 364.13 CNTRL#2 RIM: 358.84 N 595871.59 E 1106964.35 IE: 354.00 18" (NE) IE: 354.00 18" (S) IE: 351.24 8" (N) 66 LF 12" CPEP @ 3.24% 26 LF 18" CPEP @ 9.77% 31 LF 18" CPEP @ 4.09% OUTLET FROM SOUTH POND IE: 351.50 18" (SW) OUTLET TO SOUTH POND IE: 353.00 12" (E) OUTLET SOUTH POND IE: 352.75 18" (N) 3 6 0 3 5 2 3 5 4 3 5 6 3 5 8 3 6 2 A C5.2 0+ 0 0 1+ 0 0 1 + 7 2 B C5.2 JA C K S O N ST . S E 1 C5.2 8.43' EMERGENCY OVERFLOW SPILLWAY 5 C5.5 GRAVEL ACCESS ROAD3 C5.5 15 . 0 0 ' 15 . 0 0 ' 15. 0 0 ' R2 5 . 0 0 ' 6' CHAINLINK FENCE R 4 0 . 0 0 ' R40.00' 26 LF 8" 8" CPEP @ 1.00% S POND GRAVITY DRAIN OUTLET IE: 351.50 8" (S) 340 345 350 355 360 365 340 345 350 355 360 365 35 3 . 5 0 10+50 35 0 . 0 0 35 0 . 0 0 11+00 35 0 . 0 0 35 0 . 0 0 11+50 35 0 . 0 0 35 1 . 6 5 12+00 35 0 . 0 0 34 9 . 0 0 12+50 35 3 . 3 2 36 0 . 0 3 EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE ELEVATION AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE 2 : 1 3 : 1 2:1 2 : 1 3:1 TOP FC STORAGE ELEV: 357.00 WATER QUALITY ELEV: 354.00 TOP SEDIMENT STORAGE BOTTOM WQ ELEV: 350.00 4.0' 3.00' 1.0' IE: 353.00 66 LF 12" CPEP @ 3.24% 1.0' FREEBOARD 6.00' INTERNAL BERM WIDTH ELEV: 350.00 ELEV: 349.00 INTERNAL BERM ELEV: 353.003.50' 3.00' BENCH 3.50'3:1 3.50' 3.00' BENCH 343 345 350 355 360 343 345 350 355 360 35 7 . 7 9 0+50 35 4 . 2 3 35 0 . 0 0 1+00 35 0 . 0 0 35 0 . 0 0 1+50 35 6 . 4 9 TOP FC STORAGE ELEV: 357.00 WATER QUALITY ELEV: 354.00 31 LF 18 " C P E P @ 4 . 0 9 % 26 LF 18" CPEP @ 9.77% 1.0' FREEBOARD IE: 351.50 4.0' 3.00' EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE 6.00' BERM WIDTH ELEV: 350.00 TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER IE: 351.50 26 LF 8" CPEP @ 1.00% IE: 352.35 3.00' BENCH 3.00' BENCH 3:1 3:1 3 : 1 3 : 1 N GRAPHIC SCALE 0 20 40 FEET 1" = 20 FEET 10 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.2 30 TRACT F STORM POND PLAN & PROFILE A SCALE: H:1" = 20', V:1" = 4' TRACT F POND SECTION A B SCALE: H:1" = 20', V:1" = 4' TRACT F POND SECTION B NOTES: 1.PIPE SUPPORTS AND RESTRICTOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2" IN WALL. 2.THE RESTRICTOR/SEPARATOR SHALL BE FABRICTED FROM .060" ALUMINUM, OR .064" ALUMINIZED STEEL, OR .064" GALVANIZED STEEL PIPE; IN ACCORDANCE WITH AASHTO M 36, M 196, M 197 AND M 274. GALVANIZED STEEL SHALL HAVE TREATMENT 1. 3.OUTLET SHALL BE CONNECTED TO DRAIN PIPE WITH A STANDARD COUPLING BAND FOR CORRUGATED METAL PIPE. 4.THE VERTICAL RISER STEM OF THE RESTICTOR SHALL BE THE SAME DIAMETER AS THE HORIZONTAL OUTLET PIPE. 5.FRAME AND LADDER OR STEPS OFFSET SO THAT: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. SECTION 18" SD FROM POND18" SD TO DISPERSAL IE= 354.00 PIPE SUPPORT(S): 3" x 0.090" TOP OF FLAT SLAB = 358.17 ELEV = 357.00 5.9" NOTCH 0.64 FT FROM TOP PIPE POLYPROPYLENE- COATED STEEL STEPS OR LADDER. CLEANOUT GATE: SHEAR GATE IE= 354.00 54" DIA. 2. 0 ' 2. 0 ' 1.0' MIN. 18 " M A X . 6" MI N . 18" RISER RESTRICTOR PLAN W/ ONE 3.05" ORIFICE. ORIFICE ELEV = 352.00 RIM = 358.84 PLAN 18 " I N F R O M P O N D 18" OUTLET TO WETLAND OUTLET 1 NOT TO SCALE SOUTH POND CONTROL STRUCTURE (CNTRL#2) 1 C5.7 1 C5.3 10/09/2024 332 334 330 3 3 0 3 2 8 32 8 3 3 2 332 3 3 2 CB#11 CB TYPE 1 RIM: 334.47 IE: 331.52 12" (NW) IE: 331.52 12" (NE) CB#12 CB TYPE 1 RIM: 334.47 IE: 331.37 12" (SW) IE: 331.37 12" (NE) OUTLET TO WQ STRUCTURE IE: 331.20 12" (SW) 2 0 0 L F 1 2 " C P E P @ 2 . 7 1 % 23 LF 12" CPEP @ 0.75% 10+ 0 0 11+ 0 0 11+ 7 5 332 334 33 6 336 3 3 6 3 3 2 3 3 4 336 3 C5.3 B E R R Y V A L L E Y R D 30 LF 12" CPEP @ 0.51% 3,840 SF MINIMUM INFILTRATION AREA 24 LF 12" 12" CPEP @ 1.68%OUTLET TO EAST POND IE: 328.50 12" (SW) OUTLET FROM WQ IE: 328.90 12" (NE) CB#13 TYPE 1 RIM: 335.60 IE: 332.74 6" (NW) IE: 331.72 8" (E) RD OUTLET TO EAST POND IE: 328.00 8" (W) 320 325 330 335 340 320 325 330 335 340 33 4 . 5 8 10+50 33 4 . 8 5 33 5 . 1 8 11+00 32 9 . 6 9 32 8 . 0 0 11+50 32 9 . 9 3 PROPERTY LINE 56' ROW BERRY VALLEY ROAD STA: 10+18.10, 4.06 L IE: 331.52 12" (NW) IE: 331.52 12" (NE) RIM: 334.47 CB#11, CB TYPE 1 30 LF 12" CPEP @ 0.51% STA: 10+47.93, 4.61 L IE: 331.37 12" (SW) IE: 331.37 12" (NE) RIM: 334.47 CB#12, CB TYPE 1 23 LF 12" CPEP @ 0.75% IE: 331.20 3:1 2 : 1 EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE ELEVATION AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE 3.0' INFILTRATION POND STORAGE DEPTH 6.00' BERM WIDTH 3 : 1 1.0' FREEBOARD INFILTRATION POND. DO NOT COMPACT NATIVE MATERIALS. PROTECT DURING CONSTRUCTION TO PRESERVE INFILTRATION ABILITY TILL BERM. COMPACT IN 8" LIFTS (95%) TO SATISFACTION OF GEOTECHNICAL ENGINEER BOTTOM OF INFILTRATION POND ELEV: 328.00 IE: 328.90 RIM: 335.35 24 LF 12" 12" CPEP @ 1.68% IE: 328.50 INTO POND N GRAPHIC SCALE 0 20 40 FEET 1" = 20 FEET 10 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.3 31 TRACT A BIORETENTION POND PLAN & PROFILE EXISTING AND/OR PROPOSED GROUND 1' M I N . 4" MIN. FACE QUARRY ROCK 12" MIN. DEPTH OUTFALL P I P E OUTFALL PIPE GEOTEXTILE FABRIC UNDER ROCK 7' MIN 4' M I N . 1 NOT TO SCALE ROCK FALL PROTECTION 3 SCALE: H:1" = 20', V:1" = 4' TRACT A SECTION STORMFILTER WATER QUALITY STRUCTURE WITH MINIMUM 9 - 18" CARTRIDGES, OR APPROVED EQUIVALENT TREATING 0.2476 CFS OFF-LINE OR 0.4389 CFS ONLINE 2 NOT TO SCALE WATER QUALITY STRUCTURE 2 C5.3 10/09/2024 S80° 39' 28" W CB#41 CB TYPE 1 RIM: 327.58 IE: 325.58 12" (W) IE: 325.58 12" (N) 257 LF 12" D I @ 0 . 5 8 % 21 LF 12" DI @ 0.38% BERRY VAL L E Y R D OUTLET TO TRACT K POND IE: 325.50 12" (S) 3 2 6 3 2 6 326 326 328328 328 328 2 C5.4 3 C5.4 320 325 330 320 325 330 320 325 330 320 325 330 32 5 . 5 0 10+50 32 5 . 5 0 32 5 . 5 0 32 5 . 5 0 10+50 32 6 . 0 6 EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE ELEVATION AT SECTION LINE EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED GRADE ELEVATION AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE IE: 325.50 21 LF 12" DI @ 0.38% 3 : 1 3:1 3 : 1 1: 1 0.5' BIORETENTION PONDING DEPTH 0.5' BIORETENTION PONDING DEPTH BIORETENTION/INFILTRATION DO NOT COMPACT NATIVE MATERIALS. PROTECT DURING CONSTRUCTION TO PRESERVE INFILTRATION ABILITY N GRAPHIC SCALE 0 20 40 FEET 1" = 20 FEET 10 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.4 32 TRACT K STORM POND PLAN & PROFILE 2 SCALE: H:1" = 20', V:1" = 4' EAST WEST SECTION VIEW 3 SCALE: H:1" = 20', V:1" = 4' NORTH SOUTH SECTION VIEW S E E O F F S I T E I M P R O V E M E N T S P E R M I T N O . SEE PERMIT #______ FOR OFFSITE IMPROVEMENTS 1 NOT TO SCALE BIORETENTION BIORETENTION PLANTING NOTES ALL BIORETENTION AREAS SHALL BE SEEDED BY AN APPROVED HYDROSEEDER WHICH UTILIZES WATER AS THE CARRYING AGENT, AND MAINTAINS CONTINUOUS AGITATION THROUGH PADDLE BLADES. IT SHALL HAVE AN OPERATING CAPACITY SUFFICIENT TO AGITATE, SUSPEND, AND MIX INTO A HOMOGENEOUS SLURRY THE SPECIFIED AMOUNT OF SEED, WATER, FERTILIZER AND MULCH. GRASS SEED ALL GRASS MIXTURES SHALL CONTAIN FRESH, CLEAN, NEW CROP SEED. SEED IS TO BE MIXED MECHANICALLY ON THE SITE, OR MAY BE MIXED BY THE DEALER. IF SEED IS MIXED ON-SITE, EACH VARIETY SHALL BE DELIVERED IN THE ORIGINAL CONTAINERS BEARING THE DEALER'S GUARANTEED ANALYSIS. IF SEED IS MIXED BY THE DEALER, THE CONTRACTOR SHALL FURNISH TO THE LANDSCAPE ARCHITECT THE DEALER'S GUARANTEED STATEMENT OF THE COMPOSITION OF THE MIXTURE AND THE PERCENTAGE OF PURITY AND GERMINATION OF EACH VARIETY. GRASS SEED SHALL BE PURCHASED FROM A RECOGNIZED DISTRIBUTOR AND SHALL BE COMPOSED OF THE FOLLOWING VARIETIES MIXED IN THE PROPORTIONS INDICATED. SEED SHALL MEET THE MINIMUM PERCENTAGES OF PURITY AND GERMINATION SPECIFIED. SEED "A" THROUGH "H" SHALL BE APPLIED AT THE RATE OF 240 POUNDS PER ACRE, UNLESS OTHERWISE SPECIFIED BELOW ON THE APPROVED PROJECT PLANS. WATER THE CONTRACTOR IS RESPONSIBLE FOR ENSURING A WELL-ESTABLISHED STAND OF GRASS THAT IS ACCEPTABLE TO THE LANDSCAPE ARCHITECT FOR THE PURPOSE INTENDED. WATERING IS SUGGESTED AT LEAST TWICE A WEEK DURING THE GROWING SEASON AND AS NEEDED AFTERWARDS. WHEN GRASS IS REQUIRED AS A BEST MANAGEMENT PRACTICE ON STEEP SLOPES, NON-GERMINATED SEEDS SHALL BE KEPT MOIST, AND ROOTED GRASS SHALL HAVE AT LEAST 1 INCH OF WATER PER MONTH DURING THE PERIOD FROM MAY 15 THROUGH SEPTEMBER 15. FERTILIZER FERTILIZER SHALL BE A COMMERCIAL MIX WITH A 16-14-8 FORMULA, INCLUDING 50 PERCENT SLOW RELEASE NITROGEN, OR THAT MIX AS RECOMMENDED BY THE SEED SUPPLIER AND APPROVED FOR USE BY THE LANDSCAPE ARCHITECT. GRASS MIXES USED SHALL MEET THE FOLLOWING SPECIFICATIONS: % BY WEIGHT BIORETENTION GRASS: FESTUCA ARUNDINACEA / TALL FESCUE 33% HYDROSEED FESTUCA RUBRA / RED FESCUE 33% HYDROSEED LOLIUM PERENNE / PERENNIAL RYEGRASS 33% HYDROSEED REFER TO LANDSCAPE PLAN SHEETS L1.2 - L1.4 FOR BIORETENTION POND PLANTINGS. BIORETENTION NOTES: 1.BIORETENTION SOIL MEDIA SHALL BE A MIXTURE OF 50% AGGREGATE AND 50% TOPSOIL. 2.AGGREGATE SHALL BE SCREEN OR UTILITY SAND WITH: A.2% TO 4% PASSING THE #200 SIEVE B.A COEFFICIENT OF UNIFORMITY (CU) GREATER THAN 6 C.A COEFFICIENT OF CURVE(CC) BETWEEN 1 AND 3 3.BIORETENTION SOIL MEDIA SHALL HAVE A MEASURED INFILTRATION RATE NO GREATER THAN 12 INCHES PER HOUR AND A MINIMUM LONG TERM INFILTRATION RATE OF 3 INCHES PER HOUR. 4.BIO-RETENTION AREA SHALL BE HYDROSEEDED PER BIORETENTION HYDROSEED NOTES ON THIS SHEET. 5.EXTEND BIORETENTION MIX TO W.Q. SURFACE. 6" 18 " M I N . PER PLAN BOTTOM ELEVATION PER PLAN 3 H : 1 V 3H: 1 V NATIVE SUBGRADE, DO NOT COMPACT NATIVE MATERIAL UNDER BIO-RETENTION SWALES. BIORETENTION SOIL MIX SEE NOTE 2 389.0 BIORETENTION SOIL MIX NOTES: 1.BIORETENTION MIX SHALL MEET THE DEFAULT BIORETENTION SOIL MIX AS DETERMINED IN THE PIERCE COUNTY STORMWATER MANAGEMENT MANUAL UNDER VOLUME III SECTION 3.4.6. ALSO SEE CHECKLIST 14: BIORETENTION CELLS, SWALES, AND PLANTER BOXES ATTACHED TO STORM REPORT. 2.BIORETENTION SOIL SHALL CONSIST OF TWO PARTS FINE COMPOST (APPROXIMATELY 35 TO 40 PERCENT) BY VOLUME AND THREE PARTS MINERAL AGGREGATE (APPROXIMATELY 60 TO 65 PERCENT), BY VOLUME. THE MIXTURE SHALL BE WELL BLENDED TO PRODUCE A HOMOGENOUS MIX. 2.1.MINERAL AGGREGATE, MINERAL AGGREGATE GRADATION, AND COMPOST MATERIAL SHALL MEET THE SPECIFICATIONS UNDER THE PIERCE COUNTY SWMM VOLUME III SECTION 3.4.6. 2.2.COMPOST TO AGGREGATE RATIO: 60-65 PERCENT MINERAL AGGREGATE, 35-40 PERCENT COMPOST. 2.3.ORGANIC MATTER CONTENT: 5-8 PERCENT BY WEIGHT. 2.4.CATION EXCHANGE CAPACITY (CEC) MUST BE GREATER THAN 5 MILLIEQUIVALENTS/100G DRY SOIL. ACCEPTABLE COMPOST PRODUCT SOURCES INCLUDE: ·CEDAR GROVE COMPOSTING, WASHINGTON ·OTHER APPROVED EQUAL (MEETING THE SPECIFICATIONS IDENTIFIED ABOVE) ALTERNATIVE: CUSTOM BIORETENTION MIX MAY BE ACCEPTED IF TESTED TO MEET REQUIREMENTS IN THE PIERCE COUNTY STORMWATER MANAGEMENT MANUAL AND APPROVED BY ENGINEER AND COUNTY. 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.5 33 STORM DRAINAGE NOTES AND DETAILS YELM STORMWATER NOTES 1.THE CONTRACTOR SHALL OBTAIN ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM (CITY) PRIOR TO THE START OF CONSTRUCTION. A GRADING PERMIT FOR STORM POND CONSTRUCTION MAY BE REQUIRED. 2.STORM DRAIN PIPE SHALL BE ON THE WSDOT QUALIFIED PRODUCTS LIST FOR THE SPECIFICATION LISTED BELOW: A.PLAIN CONCRETE STORM SEWER PIPE OR REINFORCED CONCRETE STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.7. B.SOLID WALL PVC STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9- 05.12(1). C.DUCTILE IRON SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.13. D.HANCOR BLUE SEAL ™ AND ADVANCED DRAINAGE SYSTEMS (ADS/HANCOR) N-12 HDPE AND (ADS/HANCOR) SANITITE UP TO 36” IN DIAMETER PER WSDOT STANDARD SPECIFICATIONS 9-05.20 AND 9-05.24. E.CONTECH DUROMAXX STEEL RIB REINFORCED POLYETHYLENE PIPE, IN DIAMETERS FROM 24 INCH TO 60 INCH PER WSDOT STANDARD SPECIFICATION 9-05.22. 3.ALL STORM DRAINAGE SYSTEMS SHALL BE AIR TESTED AT 4 PSI EXCEPT CONCRETE PIPE, WHICH SHALL BE TESTED PER WSDOT/APWA STANDARD FOR CONCRETE STORM PIPE. ALL FLEXIBLE PIPE SHALL BE MANDREL TESTED PER WSDOT/APWA STANDARDS. TESTING SHALL BE DONE BY THE CONTRACTOR. 4.TESTING OF THE STORM SEWER SHALL INCLUDE VIDEOTAPING OF THE MAIN BY THE CONTRACTOR. IMMEDIATELY PRIOR TO VIDEOTAPING, ENOUGH WATER SHALL BE RUN DOWN THE LINE SO IT COMES OUT THE LOWER CATCH BASIN. A COPY OF THE VIDEO TAPE SHALL BE SUBMITTED TO THE CITY. ACCEPTANCE OF THE LINE WILL NOT BE MADE UNTIL AFTER THE TAPE HAS BEEN REVIEWED AND APPROVED BY THE CITY. TESTING SHALL TAKE PLACE AFTER ALL UNDERGROUND UTILITIES ARE INSTALLED AND COMPACTION OF THE ROADWAY SUBGRADE IS COMPLETE. 5.SPECIAL STRUCTURES, OIL/WATER SEPARATORS AND OUTLET CONTROLS SHALL BE INSTALLED PER PLANS AND MANUFACTURERS' RECOMMENDATIONS. WHERE OIL/WATER SEPARATORS ARE CONNECTED TO A SEWER SYSTEM, THEY SHALL BE INSTALLED WITH A P-TRAP OR CHECK VALVE TO PREVENT ODORS. 6.ALL DISTURBED AREAS SHALL BE STABILIZED IN ACCORDANCE WITH MINIMUM REQUIREMENT 2 OF THE LATEST EDITION OF THE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON (SWMMWW). FOR SITES WHERE VEGETATION HAS BEEN PLANTED THROUGH HYDRO SEEDING, THE FINANCIAL GUARANTEE WILL NOT BE RELEASED UNTIL THE VEGETATION HAS BEEN THOROUGHLY ESTABLISHED. 7.WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", THE CONTRACTOR SHALL EXPOSE SUCH CONNECTION POINTS AND FITTINGS 48 HOURS PRIOR TO DISTRIBUTING SHUTDOWN NOTICES. 8.ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER AND THE CITY’S CIVIL REVIEW ENGINEER. 9.ALL STORM PIPE SHALL BE A MINIMUM OF 12-INCH DIAMETER FOR MAINS AND CROSSINGS. WHEN PRIVATE STORMWATER (I.E. ROOF, LOT OR FOOTING DRAINS) CANNOT BE INFILTRATED ON INDIVIDUAL LOTS, THE MINIMUM STANDARD PIPING CONNECTION TO THE PUBLIC SYSTEM SHALL BE 8-INCH PVC. THE 8-INCH MAIN USED FOR CONNECTION SHALL BEGIN AT THE RIGHT-OF-WAY, AND THE CONNECTION TO THE CATCH BASIN OR MANHOLE SHALL BE CORED AND GROUTED. 10.ALL STORM MAINS AND RETENTION/DETENTION AREAS SHALL BE STAKED FOR GRADE AND ALIGNMENT BY AN ENGINEERING OR SURVEY FIRM LICENSED TO PERFORM SUCH WORK. 11.THE MINIMUM STAKING OF STORM SEWER SYSTEMS SHALL BE IN ACCORDANCE WITH SECTION 3.00.050 OF THESE STANDARDS, AND AS FOLLOWS: A.STAKE LOCATION OF ALL CATCH BASINS, MANHOLES AND OTHER FIXTURES FOR GRADE AND ALIGNMENT. B.STAKE LOCATION, SIZE, AND DEPTH OF RETENTION/DETENTION FACILITY. C.STAKE FINISHED GRADE OF ALL STORMWATER FEATURES, INCLUDING BUT NOT LIMITED TO CATCH BASIN/MANHOLE RIM ELEVATIONS, OVERFLOW STRUCTURES, WEIRS, AND INVERT ELEVATIONS OF ALL PIPES IN CATCH BASINS, MANHOLES, AND PIPES THAT DAYLIGHT. 12.PIPE MATERIALS USED FOR STORMWATER CONVEYANCE SHALL BE AS APPROVED BY THE CITY. PIPE SIZE, SLOPE, COVER, ETC., SHALL BE AS SPECIFIED IN THE CITY OF YELM DEVELOPMENT GUIDELINES AND ENGINEERING STANDARDS. 13.ALL DRIVEWAY CULVERTS SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. CULVERTS SHALL HAVE BEVELED END SECTIONS TO MATCH THE SIDE SLOPE. 14.IF DRAINAGE OUTLETS (STUB-OUTS) ARE TO BE PROVIDED FOR EACH INDIVIDUAL LOT, THE STUB OUTS SHALL CONFORM TO THE FOLLOWING: A.EACH OUTLET SHALL BE LOCATED AT THE LOWEST ELEVATION ON THE LOT, TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE. EACH OUTLET SHALL HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORM WATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B.OUTLETS ON EACH LOT SHALL BE LOCATED WITH A 5-FOOT HIGH, 2"X 4" STAKE MARKED "STORM" OR "DRAIN." THE STUB-OUT SHALL VISIBLY EXTEND ABOVE SURFACE LEVEL AND BE SECURED TO THE STAKE.PIPE MATERIAL SHALL BE AS APPROVED BY THE CITY. C.DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. D.THE DEVELOPER AND/OR CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB-OUT CONVEYANCE LINES WITH RESPECT TO THE UTILITIES E.POWER, GAS, TELEPHONE, TELEVISION). ALL INDIVIDUAL STUB-OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOMEOWNER. 15.THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO APPROVED PLANS ON FILE WITH THE CITY. ANY MATERIAL DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY. 16.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR SIMILARLY STABILIZED TO THE SATISFACTION OF THE CITY. FOR SITES WHERE GRASS HAS BEEN PLANTED THROUGH HYDRO SEEDING, THE PERFORMANCE BOND WILL NOT BE RELEASED UNTIL THE GRASS HAS BEEN THOROUGHLY ESTABLISHED, UNLESS OTHERWISE APPROVED BY THE CITY. 17.ALL BUILDING DOWNSPOUTS ON COMMERCIAL SITES SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS OTHERWISE APPROVED BY THE CITY. 18.ALL EROSION CONTROL AND STORMWATER FACILITIES SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE CONTRACTOR DURING THE CONSTRUCTION PHASE OF THE DEVELOPMENT PROJECT. 19.NO FINAL CUT OR FILL SLOPE SHALL EXCEED TWO (2) HORIZONTAL TO ONE (1) VERTICAL WITHOUT STABILIZATION BY ROCKERY OR BY A STRUCTURAL RETAINING WALL. 20.THE PROJECT ENGINEER SHALL VERIFY THE LOCATIONS, WIDTHS, THICKNESSES, AND ELEVATIONS OF ALL EXISTING PAVEMENTS AND STRUCTURES, INCLUDING UTILITIES AND OTHER FRONTAGE IMPROVEMENTS, THAT ARE TO INTERFACE WITH NEW WORK, AND PROVIDE ALL TRIMMING, CUTTING, SAW CUTTING, GRADING, LEVELING, SLOPING, COATING, AND OTHER WORK, INCLUDING MATERIALS NECESSARY TO CAUSE THE INTERFACE WITH EXISTING WORKS TO BE PROPER, WITHOUT CONFLICT, ACCEPTABLE TO THE PROJECT ENGINEER AND THE CITY’S CIVIL REVIEW ENGINEER, COMPLETE IN PLACE, AND READY TO USE. 21.COMPACTION OF ALL FILL AREAS SHALL BE PER CURRENT APWA SPECIFICATIONS. FILL SHALL BE PROVIDED IN 6" MAXIMUM LIFTS AND SHALL BE COMPACTED TO 95 PERCENT OF ITS MAXIMUM RELATIVE DENSITY. SECTION A-A PLAN 1.THIS TRENCH SHALL BE CONSTRUCTED SO AS TO PREVENT POINT DISCHARGE AND/OR EROSION. 2.TRENCHES MAY BE PLACED NO CLOSER THAN 50 FEET TO ONE ANOTHER. (100 FEET ALONG FLOWLINE) 3.TRENCH AND GRADE BOARD MUST BE LEVEL. ALIGN TO FOLLOW CONTOURS OF SITE. 4.SUPPORT POST SPACING AS REQUIRED BY SOIL CONDITIONS TO ENSURE GRADE BOARD REMAINS LEVEL. NOTES: *20% MAX 15% M A X A FLOW TO SECOND DISPERSAL TRENCH IF NECESSARY FLOW TO OTHER BRANCHING CB'S AS NECESSARY *15% MAX FOR FLOW CONTROL/WATER QUALITY TREATMENT IN RURAL AREAS. 18" O.C. 2" 2" 2" GRADE BOARD NOTCHES FILTER FABRIC 4"x4" SUPPORT POST 6" MI N . CLEAN - (<5% FINES) 3/4" - 1 1/2" WASHED ROCK 6" MIN. PERFORATED PIPE LAID FLAT 12 " M I N . - 3 6 " M A X . 2"x12" PRESSURE TREATED GRADE BOARD GALVANIZED BOLTS PIPE O.D. 1'-0" MIN. 1'-0" MIN. TYPE I CATCH BASIN WITH SOLID COVER A 50 ' NOTCHED GRADE BOARD 2"x2" NOTCHES 18" O.C. CLEAN OUT WYE FROM PIPE INFLUENT PIPE (MAX DESIGN - FLOW <0.5 CFS PER TRENCH) TYPE I CATCH BASIN WITH SOLID COVER (LOCKING) 4" OR 6" PERFORATED PIPE LAID FLAT/LEVEL CLEAN OUT WYE FROM PIPE END CAP OR PLUG 1'-0" MIN. PIPE O.D. 1'-0" MIN. NOTES: 1.DEPTHS ARE COMPACTED THICKNESS. 2.THE CONTRACTOR SHALL EXPOSE EXISTING FILL, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. 6" CRUSHED SURFACING TOP COURSE PER WSDOT 9.03-9(3) 12" COMPACTED SUBGRADE TO 95% 1 NOT TO SCALE DISPERSION TRENCH - NOTCHED BOARD 3 NOT TO SCALE POND ACCESS ROAD SECTION 5 NOT TO SCALE EMERGENCY OVERFLOW SPILLWAY - SOUTH POND 12" MIN. THICKNESS ROCK PROTECTION 10: 1 10:1 TOP OF SPILLWAY/BERM ELEV=358.00 TOP OF ROCK. ELEV=357.10 BOTTOM OF ROCK. ELEV.=356.10 OVERFLOW WATER SURFACE 357.50 3 1 3 1 SECTION BB SEPARATION GEOTEXTILE FABRIC COMPACTED TILL BERM FOR ANTI-SEEPAGE BOTTOM OF BIORETENTION POND ELEV: 348.79 DESIGN MAXIMUM WATER SURFACE ELEV: 357.10 1' ROCK PROTECTION 1' MIN. FREEBOARD DESIGN WATER SURFACE NOTE: PROVIDE QUARRY SPALLS FOR ROCK PROTECTION WSDOT SPEC 9-13.1. REASONABLY WELL GRADED, MAX. STONE SIZE 12", MEDIAN STONE SIZE 8", MIN. STONE SIZE 2" COMPACTED TILL BERM 8.4' 0. 4 ' 0. 5 ' MI N . 6'± AT SPILLWAY BB 2 NOT TO SCALE DISPERSION TRENCH SIZING 12" MIN. THICKNESS ROCK PROTECTION 10: 1 10:1 TOP OF SPILLWAY/BERM ELEV=346.00 TOP OF ROCK. ELEV=345.10 BOTTOM OF ROCK. ELEV.=344.10 OVERFLOW WATER SURFACE 345.50 3 1 3 1 SECTION BB SEPARATION GEOTEXTILE FABRIC COMPACTED TILL BERM FOR ANTI-SEEPAGE BOTTOM OF DETENTION POND ELEV: 334.00 DESIGN MAXIMUM WATER SURFACE ELEV: 345.10 1' ROCK PROTECTION 1' MIN. FREEBOARD DESIGN WATER SURFACE NOTE: PROVIDE QUARRY SPALLS FOR ROCK PROTECTION WSDOT SPEC 9-13.1. REASONABLY WELL GRADED, MAX. STONE SIZE 12", MEDIAN STONE SIZE 8", MIN. STONE SIZE 2" COMPACTED TILL BERM 10.2' 0. 4 ' 0. 5 ' MI N . 6'± AT SPILLWAY BB 4 NOT TO SCALE EMERGENCY OVERFLOW SPILLWAY - WEST POND AA AA SECTION AA SECTION AA FILTER FABRIC SEPARATION 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.6 34 STORM DRAINAGE NOTES AND DETAILS CAP AT END 7-3/4" 15" 8" 7" PACKING 45° (1/8) BEND 2-7/8" 2'-0"10" 8-3/4" 1-1/4" 1/2"2" 9" 1" 1" FIBRE JOINT4" 1. PIPE MATERIAL AS SPECIFIED BY THE ENGINEER. 2. PIPE DIAMETER AS SHOWN 5/8" 1'-0" NOTES: 1/2" PER PLAN. RAISE - 1/2" WIDE BORDER PROVIDE COUPLINGS & REDUCERS AS NECESSARY 3000 PSI CLASS C CONCRETE (TYP.) (LANDSCAPE AREAS ONLY) NOTE BACKFILL MATERIAL SHALL NOT HAVE PARTICLE SIZE GREATER THAN 1" WITHIN 6" OF THE PIPE OR THE CONTRACTOR HAS THE OPTION TO USE GRAVEL BACKFILL PIPE ZONE BEDDING CONFORMING TO W.S.D.O.T. 9-03.12 (3). 6" PVC FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 3" 4" M I N . ( T Y P . ) 34" 5" #3 BAR EACH WAY SEE NOTE 1 NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED ACCORDING TO THE STANDARD SPECIFICATIONS), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'. 4.THE FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP OR DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1:24 OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE BASIN HAS BEEN PLACED. #3 BAR EACH CORNER #3 BAR EACH CORNER 18" MIN. 26" (SEE N O T E 6 ) 22 " (S E E N O T E 6 ) 4" 44 " 21 " M I N . 24" 30 " 20 " 5" 6" OR 12" ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT ALTERNATIVE PRECAST BASE SECTION #3 BAR EACH SIDE SECTION B-B #3 BAR HOOP *CORRUGATED POLYETHYLENE STORM SEWER PIPE PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP* (STD. SPEC. 9-05.20)12" SOLID WALL PVC (STD. SPEC. 9-05.12(1))15" PROFILE WALL PVC (STD. SPEC. 9-05.12(2))15" NOTE: 1.NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2.THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3.THE RECTANGULAR FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP OR DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4.KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. SEPARATE BASE PRECAST INTEGRAL BASE PRECAST WITH RISER 6" 24 " M I N . 12 " MA X . 1" M I N 2. 5 " M A X . 12 " (T Y P . ) 15 ' - 0 " M A X . ( F O R M A I N T E N A N C E ) 6" 12" REINFORCED STEEL (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING STEPS OR LADDER MORTAR FILLET MORTAR (TYP.) 48", 54", 60", 72", 84" OR 96" FLAT SLAB TOP RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION HAND HOLD 28 " M A X . 4" M I N . 16 " M A X . CATCH BASIN FRAME AND VANED GRATE OR MANHOLE RING AND COVER PIPE ALLOWANCES CATCH BASIN DIAMETER PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP SOLID WALL PVC PROFILE WALL PVC 48"24"30"24"27"30" 54"30"36"30"27"36" 60"36"42"36"36"42" 72"42"54"42"36"48" 84"54"60"54"36"48" 96"60"72"60"36"48" CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) (STD. SPEC. 9-05.12(1)) (STD. SPEC. 9-05.12(2)) 1 2 3 1 2 3 CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48"4"6"36"8" 54"4.5"8"42"8" 60"5"8"48"8" 72"6"8"60"12" 84"8"12"72"12" 96"8"12"84"12" 6" 0D 6" MIN FLEXIBLERIGID (DI, CONC) TRENCH WIDTH PER WSDOT 2-09.4 0. 5 x O D (CPEP, CMP, PVC) BACKFILL UTILITY TRENCHES WITHIN PAVED AREAS WITH BANKRUN GRAVEL PER WSDOT 9-03.19. COMPACT TO A MINIMUM OF 95% UNLESS NOTED OTHERWISE IN PROJECT SPECIFICATIONS. TRENCHES MAY BE BACKFILLED WITH NATIVE MATERIAL AND COMPACTED TO 90% IN UNPAVED AREAS. PIPE BEDDING PER W.S.D.O.T. 9-03.12(3), 95% COMPACTION PIPE AS SPECIFIED ON PLAN OR SPECS SUBGRADE ELEVATION 1 NOT TO SCALE STORM CLEANOUT 2 NOT TO SCALE STORM TRENCH SECTION 3 NOT TO SCALE TYPE 1 CATCH BASIN 4 NOT TO SCALE TYPE 2 CATCH BASIN 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.7 35 STORM DRAINAGE NOTES AND DETAILS 1 NOT TO SCALE CHAIN LINK FENCE WSDOT STD. PLAN L-20.10-03 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-POND.dwg C5.8 36 ON LOT INFILTRATION PLAN PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E R. O . W . L I N E 5.0' SIDEYARD SETBACK STRUCTURE DRIVEWAY DRAIN TO STREET INFILTRATION TRENCH SEDIMENT CONTROL STRUCTURE INSTALL CLEANOUT AT ALL 90° BENDS 4" PVC PIPE @ 1.0% MIN. 15' HOUSE SETBACK 10.0' UTILITY EASEMENT 25.0' REAR YARD SETBACK 10.0' TRENCH SETBACK NOTE: TRENCH SHOWN IS SCHEMATIC. FINAL LOCATION AND CONFIGURATION TO BE CONFIRMED WITH EACH BUILDING PERMIT. *ON-LOT INFILTRATION NOTE: INFILTRATION TRENCHES MAY BE PLACED IN FILL MATERIAL IF THE FILL IS PLACED AND COMPACTED UNDER THE DIRECT SUPERVISION OF A GEOTECHNICAL ENGINEER OR PROFESSIONAL CIVIL ENGINEER WITH GEOTECHNICAL EXPERTISE, AND IF THE MEASURED INFILTRATION RATE IS AT LEAST 8 INCHES PER HOUR. INFILTRATION RATES CAN BE TESTED USING THE METHODS DESCRIBED IN APPENDIX III-A OF THE 2015 PIERCE COUNTY STORMWATER MANAGEMENT AND SITE DEVELOPMENT MANUAL. 10' TRENCH SETBACK GEOTEXTILE FABRIC 4.5' MAX. 3.0' MIN. 2.0' MIN. 10.0' MAX. 4" PERF PIPE @ 0.0% SLOPE CENTERED IN TRENCH WASHED ROCK 1 1/2" - 3/4" WASHED ROCK TO EXTEND TO EXISTING GRADE INFILTRATABLE SOILS. DEPTHS MAY VARY NOTES: 1.TRENCH LENGTH AND WIDTH SHALL BE CALCULATED TO PROVIDE MINIMUM REQUIRED BOTTOM AREA PER TRENCH SIZE TABLE. 2.THE PERFORATIONS SHALL BE CIRCULAR AND A MINIMUM 1/2" DIAMETER. 3.PERFORATIONS SHALL BE CLEANLY CUT AND BE SMOOTH AND UNIFORM WITH NO EXCESS MATERIAL LEFT FROM THE HOLE PERFORATIONS PROCESS. 4.THERE SHALL BE A MINIMUM OF 7 SETS OF PERFORATIONS WITH 2 HOLES PER SET OF PERFORATIONS FOR EACH 3.5' OF PIPE LENGTH. 5.RUBBER GASKETS OR GROUTING OF THE JOINTS FOR PERFORATED PIPE RUNS WILL NOT BE REQUIRED. 6.INSPECTION OF THE PERFORATED PIPE SHALL BE MADE BY THE MUNICIPALITY BEFORE INSTALLATION OF THE PIPE IN THE GROUND. 7.REFER TO ON-LOT INFILTRATION NOTE ON THIS SHEET. 8.PERFORATED PIPE SHALL NOT EXCEED 5.0' MAXIMUM DEPTH TO INVERT FOR RESIDENTIAL SEDIMENT CONTROL STRUCTURE. TRENCH SIZE IMPERVIOUS PROPOSED (SF)BOTTOM AREA REQUIRED (SF) 1,000 62 1,500 100 1,750 114 2,000 124 2,250 140 2,500 166 3,000 188 ON 40' WIDE LOTS, A MAXIMUM TRENCH LENGTH OF 20' IS ALLOWED IN ORDER TO ACCOMMODATE 10' SETBACKS. TRENCH WIDTH MAY VARY TO PROVIDE REQUIRED BOTTOM AREA. THIS TABLE SHOULD BE USED TO SIZE TRENCHES ON ALL LOTS. AN INFILTRATION RATE OF 20 INCHES PER HOUR WAS USED TO DETERMINE THESE DIMENSIONS, PER THE GEOTECHNICAL REPORT. EXTEND TRENCH BOTTOM TO NATIVE SOIL* * 1 NOT TO SCALE TYPICAL INFILTRATION TRENCH DIAGRAM 2 NOT TO SCALE INFILTRATION TRENCH 3 NOT TO SCALE SEDIMENT CONTROL STRUCTURE 10/09/2024 JA C K S O N S T S E 929394 84 696168606766 58 65 TRACT 'E' 6463 7062 2 TRACT 'G' 42 41 46 47 TR A C T ' D ' 71 TR A C T ' C ' 83 72 80 TRACT 'B' 82 81 TRACT 'A' 79 76 77 78 74 75 73 24 1 21 22 108 106 105 53 54 56 57 28 31 25 TRACT 'I' 51 50 49 59 91 89 88 87 85 97 18 23 8690 38 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 52 3 102 100 99 9596 103 98 101 36 37 35 14 6 13 5 12 4 11 10 9 16 8 15 7 17 31 36 37 39 40 35 34 33 32 30 14 20 13 19 12 11 10 9 8 15 7 29 27 26 13 12 11 10 9 8 7 17 31 27 26 28 31 21 18 38 36 37 39 40 35 34 33 32 30 14 6 20 13 5 19 12 4 11 10 9 16 8 15 7 17 29 27 26 17 6 9 18 38 11 s sss s s s s s s ssss s ss ss s s s s s s s s s s ss ss s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s ss ss s s ss ss s s s ss s s s s s s s s s s s s s s s s s s s s s s s s s s s s CB#40 CB#39 N88° 41' 33"W2646.96' N88° 17' 08"W1322.86' 369.12' S3° 21' 19"E 49.73'N87° 39' 50"E 555.81' N1 ° 0 6 ' 0 0 " E 26 4 1 . 9 4 ' S88° 50' 35"E 2653.86' S1 ° 1 4 ' 5 9 " W 26 4 8 . 8 9 ' S83° 40' 08"W 434.28' S6° 19' 52"E 101.00' S83° 40' 08"W 55.20' S6° 25' 47"W 182.32' S51 ° 3 6 ' 0 1 " W 505 . 2 8 ' S22° 58' 46"E 151.96' S1° 09' 25"W 122.53' BERRY VALLEY ROAD SE RO A D 3 ROAD 2 ROAD 1 JAC K S O N S T S E S E E S H E E T C 6 . 1 S E E S H E E T C 6 . 2 SEE S H E E T C6. 3 SEE S H E E T C6. 2 TRACT 'J' TRACT 'K' CB#41 N1 ° 1 7 ' 0 1 " E 34 5 . 0 2 ' S80° 39' 28" W 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 24, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-UTIL-OVERALL.dwg C6.0 36 OVERALL UTILITY MAP N GRAPHIC SCALE 0 80 160 FEET 1" = 80 FEET 40 SE E C6 . 0 O F F S I T E I M P R O V E M E N T S SE E C6 . 0 10/09/2024 929394 84 69686766656463 70 TR A C T ' D ' 71 TR A C T ' C ' 83 72 80 TRACT 'B' 82 81 TRACT 'J' TRACT 'A' 79 76 77 78 74 75 73 91 89 88 87 85 8690 TRACT 'K' s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 3+00 S83° 40' 08"W 55.20' 1 0 1 . 0 0 ' N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SE E S H E E T C6 . 2 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 24, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-UTIL.dwg C6.1 38 UTILITY MAP (NE) WETLAND BUFFER WETLAND BUFFER EDGE OF WETLAND (THOMPSON CREEK) RO A D 3 BERRY VAL L E Y R O A D S E 1" SERVICE CONNECTION DOUBLE SERVICE CONNECTION (TYP.) PROPOSED STEP MAIN PROPOSED 8" WATER MAIN DUAL METER SERVICE (TYP.) PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT SINGLE METER SERVICE (TYP.) PROPOSED STEP MAIN BLOW OFF PROPOSED FIRE HYDRANT O F F S I T E I M P R O V E M E N T S SSFM END OF LINE CLEANOUT 10/09/2024 94 6160 58 TRACT 'E' 646362 2 TRACT 'G' 42 41 46 47 1 108 106 105 53 54 56 57 51 50 49 59 97 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 52 3 102 100 99 9596 103 98 101 4 4040 4 s sss s s s s s s ssss s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 3+00 1+00 2+00 S6 ° 2 5 ' 4 7 " W S83° 40' 08"W 55.20' S 6 ° 1 9 ' 5 2 " E 1 0 1 . 0 0 ' STA: 1+00 ROAD 1= STA: 11+83.49 JACKSON PROPOSED FIRE HYDRANT N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SE E S H E E T C6 . 1 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX SEE SHEET C6.3 DATE: September 24, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-UTIL.dwg C6.2 39 UTILITY MAP (NW) WETLAND BUFFER EDGE OF WETLAND J A C K S O N S T . S E ROAD 2 BERRY VALLEY ROAD SE SINGLE SERVICE CONNECTION (TYP.) DOUBLE SERVICE CONNECTION (TYP.) PROPOSED 8" WATER MAIN DUAL METER SERVICE (TYP.) PROPOSED FIRE HYDRANT SINGLE METER SERVICE (TYP.) PROPOSED STEP MAIN PROPOSED FIRE HYDRANT BLOW OFF PROPOSED 8" WATER MAIN BLOW OFF PROPOSED STEP MAIN WETLAND BUFFER SSFM END OF LINE CLEANOUT SSFM END OF LINE CLEANOUT PROPOSED 8" WATER MAIN 10/09/2024 JA C K S O N S T S E 2 42 41 24 1 21 22 108 106 105 28 31 25 TRACT 'I' 18 23 38 TRACT 'L' 107 109 43 45 TRACT 'H' 44 3 102 103 36 37 35 14 6 13 5 12 4 11 10 9 16 8 15 7 17 31 36 37 39 40 35 34 33 32 30 14 20 13 19 12 11 10 9 8 15 7 29 27 26 13 12 11 10 9 8 7 17 31 27 26 28 31 21 18 38 36 37 39 40 35 34 33 32 30 14 6 20 13 5 19 12 4 11 10 9 16 8 15 7 17 29 27 26 17 6 9 18 38 11 s s s s ss s s s s s s s s s s s s s s s s s s s s ss ss ss ss ss ss s s s s s s s s s s 0+50 1+00 2+0 0 434.28' PROPOSED FIRE HYDRANT N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 SEE SHEET C6.2 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 24, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-UTIL.dwg C6.3 40 UTILITY MAP (S) WETLAND BUFFER EDGE OF WETLAND ROAD 1 JAC K S O N S T . S E SINGLE SERVICE CONNECTION (TYP.) DOUBLE SERVICE CONNECTION (TYP.) PROPOSED 8" WATER MAIN DUAL METER SERVICE (TYP.) PROPOSED FIRE HYDRANT SINGLE METER SERVICE (TYP.) PROPOSED STEP MAIN PROPOSED FIRE HYDRANT CONNECT TO EXST. WATER STUB CONNECT TO EXISTING STEP MAIN PROPOSED 8" WATER MAIN BLOWOFF 10/09/2024 s s s s s s s s s ss s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 929394 84 69 61 68 60 6766 656463 70 62 2 71 83 72 80 TRACT 'B' 82 81 TRACT 'A' 79 76 77 78 74 75 73 1 59 91 89 88 87 85 98 97 8690 TRACT 'L' 104 55 TR A C T ' D ' TR A C T ' C ' 3 102 100 99 9596 103 101 3+00 7+00 2+00 3+00 4+00 5+00 6+00 7+00 8 + 0 0 9 + 0 0 1 0 + 0 0 1 1 + 0 0 12+00 13 + 0 0 LOT 84 & 85 LOT 82 LOT 78 & 79 LOT 76 & 77 LOT 74 & 75 LOT 72 & 73 LOT 70 & 71LOT 68 & 69 LOT 66 & 67 LOT 64 & 65LOT 62 & 63 LOT 93 & 94 LOT 83 LOT 80 & 81 FH1 FH3 WA4 350 34 8 35 2 35 4 35 6 358 35 8 3 5 6 3 5 4 3 5 2 35 0 34 8 346 344 342 340 332 3 6 4 358 356 354 352 3 6 6 364 362 360 3 5 8 368 3 3 0 3 3 2 35 0 34 6 34 8 35 2 35 4 35 6 35 8 34 0 352354356 356358 346364366 360356358362 350 3 6 2 WF5 WF6 WF8 WF9 WF11 LOT 59 LOT 60 & 61 LOT 95 & 96 LOT 91 & 92 WF1 WF3 WF7 WF25 WF4 WF10 WF29 Profile View of BERRY VALLEY26 BERRY VALLEY 340 345 350 355 360 365 370 375 340 345 350 355 360 365 370 375 324 325 330 335 340 345 350 324 325 330 335 340 345 350 35 0 . 4 9 1+50 35 0 . 2 0 35 0 . 3 6 2+00 35 0 . 9 5 35 1 . 9 9 2+50 35 3 . 2 4 35 4 . 4 9 3+00 35 5 . 6 5 35 6 . 6 3 3+50 35 7 . 4 3 35 8 . 0 5 4+00 35 8 . 4 9 35 8 . 7 5 4+50 35 8 . 8 3 35 8 . 7 4 5+00 35 8 . 4 6 35 8 . 0 0 5+50 35 7 . 3 6 35 6 . 5 5 6+00 35 5 . 5 5 35 4 . 3 8 6+50 35 3 . 0 2 35 1 . 4 9 34 8 . 2 4 7+50 34 6 . 6 1 34 4 . 9 9 8+00 34 3 . 3 6 34 1 . 8 3 8+50 34 0 . 4 8 33 9 . 3 1 9+00 33 8 . 3 3 33 7 . 5 3 9+50 33 6 . 9 2 33 6 . 4 0 10+00 33 5 . 8 8 33 5 . 3 5 10+50 33 4 . 8 3 33 4 . 3 1 11+00 33 3 . 7 9 33 3 . 2 7 11+50 33 2 . 7 4 33 2 . 2 2 12+00 33 1 . 7 4 33 1 . 3 5 12+50 33 1 . 0 3 33 0 . 8 1 13+00 33 0 . 6 2 33 0 . 4 3 2.00% 5.00% 6. 5 0 % 2.09% WF5 WF6 WF8 WF9 12" STORM BOT 346.59 8" WATER BOT 345.94 ENCASE WATER PIPE PER CROSSING NOTES ON C7.3 12" STORM BOT 331.40 8" WATER TOP 329.90 12" STORM BOT 336.93 8" WATER TOP 335.43 12" STORM BOT 344.15 8" WATER TOP 342.65 68LF 8" C900 PVC 24LF 8" C900 PVC 39LF 8" C900 PVC 37LF 8" C900 PVC 3.50', TYP COVER 3.50', TYP COVER WF7 WF3 377LF 8 " 8 " C 9 0 0 P V C WF2 21 8 L F 8 " 8 " C 9 0 0 P V C WF1 265LF 8" C900 PVC 213LF 8" C900 PVC WATER FITTING TABLE NAME WF1 WF2 WF3 WF5 WF6 WF7 WF8 WF9 STRUCTURE INFORMATION 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 9 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 9 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET BERRY VALLEY STA:1+11.00, 11.00' L BERRY VALLEY STA:1+49.00, 11.00' L BERRY VALLEY STA:5+26.77, 11.00' L BERRY VALLEY STA:7+42.60, 15.18' L BERRY VALLEY STA:8+05.27, 14.47' L BERRY VALLEY STA:10+70.17, 11.00' L BERRY VALLEY STA:12+87.21, 14.83' L BERRY VALLEY STA:13+10.69, 11.80' L WATER METER TABLE LOT/S LOT 56 LOT 59 LOT 60 & 61 LOT 62 & 63 LOT 64 & 65 LOT 66 & 67 LOT 68 & 69 DESCRIPTION SINGLE METER SINGLE METER DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER ALIGNMENT STATION OFFSET JACKSON STA:15+89.86, 19.50' L BERRY VALLEY STA:1+83.00, 19.50' L BERRY VALLEY STA:2+24.00, 19.50' L BERRY VALLEY STA:3+04.00, 19.50' L BERRY VALLEY STA:3+84.00, 19.50' L BERRY VALLEY STA:4+84.00, 19.50' L BERRY VALLEY STA:5+84.00, 19.50' L WATER METER TABLE LOT/S LOT 70 & 71 LOT 72 & 73 LOT 74 & 75 LOT 76 & 77 LOT 78 & 79 LOT 80 & 81 LOT 82 DESCRIPTION DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER SINGLE METER ALIGNMENT STATION OFFSET BERRY VALLEY STA:6+84.00, 19.50' L BERRY VALLEY STA:7+57.92, 19.50' L BERRY VALLEY STA:8+25.93, 19.50' L BERRY VALLEY STA:9+04.12, 19.50' L BERRY VALLEY STA:9+84.12, 19.50' L BERRY VALLEY STA:9+26.42, 19.50' R BERRY VALLEY STA:8+25.85, 19.50' R WATER METER TABLE LOT/S LOT 83 LOT 84 & 85 LOT 91 & 92 LOT 93 & 94 LOT 95 & 96 DESCRIPTION SINGLE METER DUAL METER DUAL METER DUAL METER DUAL METER ALIGNMENT STATION OFFSET BERRY VALLEY STA:6+64.53, 19.72' R ROAD 3 STA:2+55.66, 92.89' R ROAD 3 STA:2+55.65, 81.51' L BERRY VALLEY STA:3+54.16, 19.68' R BERRY VALLEY STA:2+74.22, 19.71' R WATER METERS SHALL BE 5 8" SEE CITY OF YELM DWG NO. 4-1 ON SHEET C7.6 FOR SINGLE METER SERVICE, AND CITY OF YELM DWG NO 4-2 ON SHEET C7.6 FOR DUAL METER SERVICE. WATER TABLE NAME FH1 FH3 DESCRIPTION Hydrant Hydrant ALIGNMENT STATION, OFFSET BERRY VALLEY STA:1+49.00, 20.00' L BERRY VALLEY STA:10+70.10, 20.00' L N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR.dwg C7.1 41 BERRY VALLEY ROAD WATER PLAN & PROFILE BERRY VALLEY ROAD SE PROFILE (STA. 1+00 - STA. 13+50) HORIZ. 1"=50', VERT. 1"=5' BERRY VALLEY ROAD SE PLAN - NEIGHBORHOOD COLLECTOR (STA. 1+00 - STA. 13+50) 1"=50' BERRY VALLEY ROAD SE EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD SEE C7.5SEE C7.4 SEE C7.4 RO A D 3 JA C K S O N S T S E SE E C7 . 2 56 10/09/2024 TRACT 'K' 1 3 + 0 0 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 FH5 FH4WF9 WF11 WF12WF10 WF10 320 325 330 335 340 345 320 325 330 335 340 345 EXISTING 24" CULVERTS 33 0 . 0 6 14+00 32 9 . 8 8 32 9 . 6 9 14+50 32 9 . 5 1 32 9 . 3 2 15+00 32 9 . 1 3 32 8 . 9 5 15+50 32 8 . 7 6 32 8 . 5 8 16+00 32 8 . 3 9 32 8 . 2 1 16+50 32 8 . 0 5 32 7 . 9 6 17+00 32 7 . 9 4 32 7 . 9 7 17+50 32 8 . 0 7 32 8 . 2 3 18+00 32 8 . 4 2 0.74% BOX CULVERT BOT 324.14 8" WATER TOP 322.60 3.50', TYP COVER 40LF 8" C900 PVC WF11 WF12 1.50' MIN COVER 33LF 8" 8" C900 PVC WF10 3 C3.12 403LF 8" C900 PVC WATER FITTING TABLE NAME WF10 WF11 WF12 STRUCTURE INFORMATION 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 9 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 16 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET BERRY VALLEY STA:13+54.19, 15.95' L BERRY VALLEY STA:13+91.21, 10.31' L BERRY VALLEY STA:17+95.62, 11.00' L WATER TABLE NAME FH4 FH5 DESCRIPTION Hydrant Hydrant ALIGNMENT STATION, OFFSET BERRY VALLEY STA:13+54.64, 24.94' L BERRY VALLEY STA:17+95.64, 21.69' L N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR.dwg C7.2 42 BERRY VALLEY ROAD WATER PLAN & PROFILE BERRY VALLEY ROAD SE PROFILE (STA. 13+50 - STA. 21+00) HORIZ. 1"=50', VERT. 1"=5' BERRY VALLEY ROAD SE PLAN - NEIGHBORHOOD COLLECTOR (STA. 13+50 - STA. 21+00) 1"=50' BERRY VALLEY ROAD SE EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD SE E C7 . 1 PROPOSED HEADWALL PROPOSED HEADWALL WETLAND BUFFER EDGE OF WETLAND (THOMPSON CREEK) PROPOSED ARCHED CULVERT WITH FOOTINGS SE E O F F S I T E I M P R O V E M E N T S PE R M I T N O . INSTALL 16" STEEL CASING FOR WATER THROUGH CULVERT FOOTING PROPOSED ARCH PIPE BOX CULVERT, SEE SHEET C3.12 FOR MORE INFORMATION 10/09/2024 JACKSON ST SE s s s s s s s s s s s s s s s s s s s s s s s s s ss s 28 31 25 24 21 22 18 23 38 36 37 35 13 12 11 31 20 19 4400 S.F. 11 28 31 18 38 18 38 14 13 12 11 16 15 17 39 40 34 33 32 27 26 1+00 2+00 3+00 4+00 5+00 6 + 0 0 7 + 0 0 8 + 0 0 9 + 0 0 WA1 WF21 FH6 LOT 25 LOT 12 & 13 LOT 14 & 15 LOT 16 & 17 LOT 18 LOT 21 & 22 LOT 23 & 24 LOT 26 & 27 LOT 28 & 29 LOT 30 & 31 LOT 32 & 33 LOT 34 & 35 LOT 36 & 37 LOT 38 & 39 LOT 19 & 20 382 3 8 6 3 7 6 3 7 8 3 5 6 3 7 0 370 3 8 0 3 6 6 3 6 8 37 237 4 37 6 3 7 8 3 8 2 382 WF13 WF14 WF15 WF16 WF17 WF18 WF19 WF20 355 360 365 370 375 380 385 390 395 355 360 365 370 375 380 385 390 395 1+00 1+50 2+00 38 0 . 9 3 2+50 38 1 . 7 7 38 2 . 2 5 3+00 38 2 . 2 9 38 1 . 8 8 3+50 38 1 . 0 3 37 9 . 8 1 4+00 37 8 . 5 6 37 7 . 3 1 4+50 37 6 . 0 6 37 4 . 8 1 5+00 37 3 . 5 6 37 2 . 3 2 5+50 37 1 . 2 0 37 0 . 2 5 6+00 36 9 . 4 7 36 8 . 8 5 6+50 36 8 . 4 0 36 8 . 1 1 7+00 36 7 . 8 6 36 7 . 6 1 7+50 36 7 . 3 6 36 7 . 1 1 8+00 36 6 . 8 5 36 6 . 6 0 8+50 36 6 . 3 5 36 6 . 1 0 9+00 36 5 . 8 5 3.50% 5.0 0 % 1.00% STA: 2+28.26 ELEV: 381.16 BEGIN ROAD IMPROVEMENTS MATCH EXISTING WF13 WF14 WF15 WF16 WF17 3LF 8" C900 PVC 22LF 8" C900 PVC 67LF 8" C900 PVC 28LF 8" C900 PVC 68 L F 8 " C 9 0 0 P V C 47 L F 8 " C 9 0 0 P V C 12" STORM BOT 366.23 8" WATER TOP 365.00 ENCASE WATER PIPE 12" STORM BOT 363.60 8" WATER TOP 363.16 ENCASE WATER PIPE 3.50', TYP COVER WA1 34LF 8" 8" C900 PVC WF20 WF19 WF18 WF21 32LF 8" C900 PVC 54 L F 8 " C 9 0 0 P V C 400LF 8" C900 PVC WATER FITTING TABLE NAME WF13 WF14 WF15 WF16 WF17 WF18 WF19 WF20 WF21 STRUCTURE INFORMATION 1 - 8" 11.25° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 11.25° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 7 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" 11.25° BEND (MJ) CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET JACKSON STA:2+32.39, 2.50' R JACKSON STA:2+54.99, 7.49' R JACKSON STA:3+21.22, 10.99' R JACKSON STA:3+48.04, 13.88' R JACKSON STA:4+15.37, 11.92' R JACKSON STA:4+66.84, 10.77' R JACKSON STA:5+26.03, 12.04' R JACKSON STA:5+61.73, 15.95' R JACKSON STA:5+98.75, 12.27' R WATER METER TABLE LOT/S LOT 12 & 13 LOT 14 & 15 LOT 16 & 17 LOT 18 LOT 19 & 20 LOT 21 & 22 LOT 23 & 24 LOT 25 LOT 26 & 27 LOT 28 & 29 LOT 30 & 31 LOT 32 & 33 LOT 34 & 35 LOT 36 & 37 DESCRIPTION DUAL METER DUAL METER DUAL METER SINGLE METER DUAL METER DUAL METER DUAL METER SINGLE METER DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER ALIGNMENT STATION OFFSET JACKSON STA:8+21.78, 22.37' R JACKSON STA:7+41.75, 22.37' R JACKSON STA:6+61.75, 22.37' R JACKSON STA:4+83.72, 22.39' R JACKSON STA:4+09.78, 22.36' R JACKSON STA:3+35.24, 22.40' R JACKSON STA:2+78.26, 22.21' R JACKSON STA:2+48.27, 23.16' L JACKSON STA:3+76.50, 22.50' L JACKSON STA:4+64.71, 22.85' L JACKSON STA:5+48.24, 20.28' L JACKSON STA:6+36.56, 22.84' L JACKSON STA:7+36.42, 24.88' L JACKSON STA:8+36.42, 24.88' L WATER METERS SHALL BE 5 8" SEE CITY OF YELM DWG NO. 4-1 ON SHEET C7.6 FOR SINGLE METER SERVICE, AND CITY OF YELM DWG NO 4-2 ON SHEET C7.6 FOR DUAL METER SERVICE. WATER TABLE NAME FH6 WA1 DESCRIPTION Hydrant CONNECT TO EXISTING 12" WATERMAIN 1- 12"x8" REDUCER (MJ) ALIGNMENT STATION, OFFSET JACKSON STA:5+61.70, 23.05' R JACKSON STA:2+28.26, 2.50' R UTILITY CROSSING NOTES 1.AT ALL UTILITY CROSSINGS: STORM PIPE SHALL BE CONSTRUCTED OF ONE SEGMENT OF THE MAXIMUM STANDARD LENGTH OF PIPE (BUT NOT LESS THAN 18 FEET LONG) WITH THE PIPES CENTERED TO MAXIMIZE JOINT SEPARATION. 2.STORM CROSSING WITHIN 18" ABOVE WATER: THE WATER PIPE SHALL BE ENCASED IN PIPE, OR CONCRETE. CONCRETE ENCASEMENT CAN ONLY BE INSTALLED WHEN SPECIFICALLY DIRECTED BY THE CITY ENGINEER. STORM SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE OR STANDARD SEWER PIPE IN A CASING EQUIVALENT TO THAT SPECIFIED IN TABLE C1-4 OF THE WASHINGTON STATE DEPARTMENT OF ECOLOGY'S CRITERIA FOR SEWAGE WORKS DESIGN (ORANGE BOOK) FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING. 3.PRESSURE SEWERS UNDER WATER LINES: THESE PRESSURE SEWERS SHALL BE CONSTRUCTED ONLY UNDER WATER LINES WITH DUCTILE IRON PIPE OR STANDARD SEWER PIPE IN A CASING EQUIVALENT TO THAT SPECIFIED ABOVE IN C1-9.1.4A OF DOE'S ORANGE BOOK. FOR A DISTANCE OF AT LEAST 10 FEET ON EACH SIDE OF THE CROSSING. N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR.dwg C7.3 43 JACKSON STREET WATER PLAN & PROFILE JACKSON STREET SE PROFILE (STA. 1+00 - STA. 9+00) HORIZ. 1"=50', VERT. 1"=5' JACKSON STREET SE PLAN - LOCAL ACCESS RESIDENTIAL (STA. 1+00 - STA. 9+00) 1"=50' J A C K S O N S T . S E EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD SEE C7.4 10/09/2024 s s s s s s s s sss s ss s s s s s s s s s s s s s ss s s s ss s s s 106 105 53 54 56 57 61 60 58 62 2 1 59 98 97 38 TRACT 'L' 104 107 55 3 102 100 99 95 96 103 101 37 11 10 9 8 7 4400 S.F. 11 38 6 9 38 6 11 10 9 8 7 5 4 39 40 9 + 0 0 1 0 + 0 0 11+ 0 0 12+00 13+00 14+00 15+00 16+00 17+00 17+50 STA: 11+83.49 JACKSON= STA: 1+00.16 ROAD 1 2+ 0 0 3+ 0 0 WF22 STA: 16+06.86 JACKSON= STA: 1+00.00 BERRY VALLEY WA2 LOT 56 LOT 40 LOT 57 & 58 LOT 97 LOT 100 & 101 LOT 102 & 103 LOT 6 & 7 LOT 8 & 9 LOT 10 & 11 LOT 38 & 39 LOT 104 & 105 LOT 106 & 107 LOT 53 & 54 LOT 98 & 99 STA: 14+37.61 JACKSON= STA: 7+06.91 ROAD 2 35 0 34 8 352 354 364 35 8 35 6 3 5 4 3 5 2 358352 35 4 368 362 LOT 4 & 5 WF1WF23 WF24 WF25 WATER TABLE NAME WA2 DESCRIPTION END WATER MAIN 1 - 4" CAP W/ 2" THREADED TAP (FL) 1 - 2" GATE FALVE W/ 2" THREADED FLANGE (FL) 1 - 2" BLOWOFF ASSEMBLY SEE YELM STD DWG. 4-9 SHEET C7.6 CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET JACKSON STA:17+27.86, 11.00' R WATER FITTING TABLE NAME WF1 WF22 WF23 WF24 WF25 WF29 STRUCTURE INFORMATION 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET BERRY VALLEY STA:1+11.00, 11.00' L JACKSON STA:10+02.11, 11.90' R JACKSON STA:10+72.03, 15.09' R JACKSON STA:11+65.30, 15.96' R JACKSON STA:11+91.72, 11.89' R JACKSON STA:14+52.18, 11.00' R WATER METER TABLE LOT/S LOT 4 & 5 LOT 6 & 7 LOT 8 & 9 LOT 10 & 11 LOT 38 & 39 LOT 40 LOT 56 LOT 57 & 58 LOT 97 LOT 98 & 99 LOT 100 & 101 LOT 102 & 103 DESCRIPTION DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER SINGLE METER SINGLE METER DUAL METER SINGLE METER DUAL METER DUAL METER DUAL METER ALIGNMENT STATION OFFSET JACKSON STA:11+15.90, 22.37' R JACKSON STA:10+55.26, 22.40' R JACKSON STA:9+81.77, 22.37' R JACKSON STA:9+01.75, 22.37' R JACKSON STA:9+36.42, 24.88' L JACKSON STA:10+74.81, 26.97' L JACKSON STA:15+89.86, 19.50' L JACKSON STA:16+84.86, 19.50' L JACKSON STA:15+16.41, 22.39' R JACKSON STA:14+63.30, 22.40' R JACKSON STA:13+83.28, 22.51' R JACKSON STA:13+57.23, 22.41' R WATER METERS SHALL BE 5 8" SEE CITY OF YELM DWG NO. 4-1 ON SHEET C7.6 FOR SINGLE METER SERVICE, AND CITY OF YELM DWG NO 4-2 ON SHEET C7.6 FOR DUAL METER SERVICE. 337 340 345 350 355 360 365 370 375 380 337 340 345 350 355 360 365 370 375 380 9+00 36 5 . 8 5 36 5 . 6 0 9+50 36 5 . 3 5 36 5 . 1 0 10+00 36 4 . 8 5 36 4 . 6 0 10+50 36 4 . 3 5 36 4 . 1 2 11+00 36 4 . 0 3 36 4 . 0 9 11+50 36 4 . 3 1 36 4 . 6 7 12+00 36 4 . 9 3 36 4 . 8 3 12+50 36 4 . 4 0 36 3 . 9 0 13+00 36 3 . 4 0 36 2 . 9 0 13+50 36 2 . 4 0 36 1 . 9 0 14+00 36 1 . 4 0 36 0 . 7 7 14+50 35 9 . 8 9 35 8 . 7 7 15+00 35 7 . 3 9 35 5 . 8 9 15+50 35 4 . 3 9 35 2 . 8 9 16+00 35 1 . 3 9 34 9 . 9 8 16+50 34 8 . 7 7 34 7 . 7 4 17+00 34 6 . 9 0 34 6 . 0 5 17+50 3.00 % 2.00% 6. 0 0 % 1.50% STA: 17+23.07 ELEV: 346.21 END ROAD IMPROVEMENTS STA: 16+06.86 ELEV: 350.99 INTERSECTION BERRY VALLEY ROAD SE STA: 14+37.61 ELEV: 360.36 INTERSECTION ROAD 2 STA: 11+83.49 ELEV: 364.82 INTERSECTION ROAD 1 EXISTING ELEVATION @ CL OF ROAD PROPOSED ELEVATION @ CL OF ROAD EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD 12" STORM BOT 360.55 8" WATER TOP 360.10 3.50', TYP COVER 402LF 8" C900 PVC 12" STORM BOT 342.53 8" WATER TOP 342.12 ENCASE WATER PIPE PER CROSSING NOTES ON C7.3 WA2 WF22 SSFM BOT 358.72 12" STORM TOP 356.38 73LF 8" C900 PVC 8" WATER BOT 353.08 12" STORM TOP 350.00 STORM CROSSING 263LF 8 " 8 " C 9 0 0 P V C WF29 WF1 110 L F 8 " 8 " C 9 0 0 P V C WF23 WF24 WF2527LF 8" C900 PVC STORM CROSSING 126LF 8" C900 PVC 163LF 8" 8" C900 PVC N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR.dwg C7.4 44 JACKSON STREET WATER PLAN & PROFILE JACKSON STREET SE PROFILE (STA. 9+00 - STA. 17+50) HORIZ. 1"=50', VERT. 1"=5' JACKSON STREET SE PLAN - LOCAL ACCESS RESIDENTIAL (STA. 9+00 - STA. 17+50) 1"=50' JACKSON ST. SE R O A D 1 RO A D 2 BE R R Y V A L L E Y R D SEE C7.3 SEE C7.5 SEE C7.1 SEE C7.5 10/09/2024 352 355 360 365 370 375 380 352 355 360 365 370 375 380 0+50 36 4 . 6 7 1+00 36 4 . 7 5 36 4 . 4 0 1+50 36 4 . 4 9 36 5 . 1 1 2+00 36 6 . 2 2 36 7 . 4 2 2+50 36 8 . 6 2 36 9 . 8 2 3+00 2.00% 4.80% STA: 1+01.14 ELEV: 364.78 INTERSECTION JACKSON ST SE STA: 2+84.29 ELEV: 370.25 END ROAD IMPROVEMENTS EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD 124L F 8 " C 9 0 0 P V C 3.50', TYP COVER SSFM BOT 358.30 12" STORM TOP 357.45 PROPOSED GRADE @ CL OF ROAD WF25 12LF 8" 8" C900 PVC WF26 30LF 8" 8" C900 PVC WF27 WF28 4LF 8" 8" C900 PVC WA3 340 345 350 355 360 365 340 345 350 355 360 365 0+25 0+50 35 0 . 9 6 35 0 . 9 7 1+00 35 1 . 2 2 35 1 . 4 7 1+50 35 1 . 7 2 35 1 . 9 7 2+00 35 2 . 2 2 35 2 . 4 7 2+50 35 2 . 7 2 35 2 . 9 7 3+00 35 3 . 2 2 35 3 . 4 7 3+50 35 3 . 7 2 35 4 . 0 0 4+00 35 4 . 3 5 35 4 . 7 5 4+50 35 5 . 2 2 35 5 . 7 2 5+00 35 6 . 2 2 35 6 . 7 2 5+50 35 7 . 2 2 35 7 . 7 2 6+00 35 8 . 2 2 35 8 . 7 2 6+50 35 9 . 2 2 35 9 . 7 2 7+00 36 0 . 1 9 36 0 . 0 6 7+50 35 9 . 5 0 STA: 0+75.00 ELEV: 350.97 CENTER CDS STA: 7+06.91 ELEV: 360.36 INTERSECTION JACKSON ST SE EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD 1.00% 2.00% WF31 WF32 93LF 8" C90 0 P V C 3.50', TYP COVER EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROADWA5 18LF 8" C900 PVC 12" STORM CROSSING 2.5" SEWER CROSSING WF30 WF33 WF29 SSFM BOT: 353.82 12" STORM TOP: 349.87 SSFM BOT: 349.44 12" STORM TOP: 347.20 12" STORM BOT: 348.05 8" WATER TOP: 346.48 12" STORM BOT: 348.41 8" WATER TOP: 346.91 212LF 8" C 9 0 0 P V C 54LF 8" C900 PVC 307LF 8" C900 PVC 345 350 355 360 365 370 375 345 350 355 360 365 370 375 0+50 36 7 . 1 6 36 6 . 1 9 1+00 36 4 . 6 9 36 3 . 1 9 1+50 36 1 . 6 9 36 0 . 1 9 2+00 35 8 . 7 7 35 7 . 9 4 2+50 35 7 . 8 0 35 8 . 1 8 3+00 35 8 . 4 7 2.00% 6. 0 0 % STA: 1+00.00 ELEV: 364.69 CENTER CDS STA: 2+75.00 ELEV: 358.19 INTERSECTION BERRY VALLEY ROAD SE EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD 18 0 L F 8 " C 9 0 0 P V C 3.50', TYP COVER EXISTING GRADE @ CL OF ROAD PROPOSED GRADE @ CL OF ROAD WF3 51LF 8" 8" C900 PVC WF4 WA4 12" STORM BOT 354.57 8" WATER TOP 352.86 WATER METER TABLE LOT/S LOT 1 LOT 2 & 3 DESCRIPTION SINGLE METER DUAL METER ALIGNMENT STATION OFFSET ROAD 1 STA:2+49.45, 23.50' L ROAD 1 STA:1+84.45, 23.50' L " SEE CITY OF YELM DWG NO. 4-1 LOT 55 LOT 104 & 105 LOT 106 & 107 LOT 108 SINGLE METER DUAL METER DUAL METER SINGLE METER ROAD 2 STA:6+52.98, 15.00' L ROAD 2 STA:6+23.36, 22.50' R ROAD 2 STA:5+21.76, 22.50' R ROAD 2 STA:4+13.98, 22.48' R WATER METER TABLE LOT/S LOT 84 & 85 LOT 86 & 87 LOT 88 & 89 LOT 90 LOT 91 & 92 DESCRIPTION DUAL METER DUAL METER DUAL METER SINGLE METER DUAL METER ALIGNMENT STATION OFFSET ROAD 3 STA:2+55.66, 92.89' R ROAD 3 STA:1+06.14, 44.05' R ROAD 3 STA:0+73.22, 35.31' L ROAD 3 STA:1+46.47, 22.50' L ROAD 3 STA:2+55.65, 81.51' L WATER METERS SHALL BE 5 8" SEE CITY OF YELM DWG NO. 4-1 ON SHEET C7.6 FOR SINGLE METER SERVICE, AND CITY OF YELM DWG NO 4-2 ON SHEET C7.6 FOR DUAL METER SERVICE. WATER FITTING TABLE NAME WF3 WF4 WF29 WF30 WF31 WF32 WF33 STRUCTURE INFORMATION 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 9 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 17 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 3 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET BERRY VALLEY STA:5+26.77, 11.00' L ROAD 3 STA:2+34.16, 11.00' R JACKSON STA:14+52.18, 11.00' R ROAD 2 STA:0+53.51, 11.01' L ROAD 2 STA:3+62.75, 14.14' L ROAD 2 STA:4+50.42, 14.29' L ROAD 2 STA:6+60.79, 11.07' L WATER TABLE NAME FH2 FH7 FH8 FH9 DESCRIPTION Hydrant Hydrant Hydrant Hydrant ALIGNMENT STATION, OFFSET ROAD 3 STA:2+34.16, 16.07' R ROAD 1 STA:1+27.04, 18.82' L ROAD 2 STA:0+53.51, 28.96' L ROAD 2 STA:6+60.71, 15.00' L WATER FITTING TABLE NAME WF25 WF26 WF27 WF28 STRUCTURE INFORMATION 1 - 8" TEE (FL) 3 - 8" GATE VALVE (FLxMJ) CONC. THRUST BLOCKING 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FLxMJ) 11 LF 6" DI CL52 1 - FIRE HYDRANT ASSEMBLY SEE YELM DWG. 4-7 SHEET C7.6 CONC. THRUST BLOCKING 1 - 8" 45° BEND (MJ) CONC. THRUST BLOCKING 1 - 8" 45° BEND (MJ) CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET JACKSON STA:11+91.72, 11.89' R ROAD 1 STA:1+26.99, 8.02' L ROAD 1 STA:1+57.53, 8.02' L ROAD 1 STA:1+60.54, 11.01' L WATER TABLE NAME WA3 WA4 WA5 DESCRIPTION END WATER MAIN 1 - 4" CAP W/ 2" THREADED TAP (FL) 1 - 2" GATE FALVE W/ 2" THREADED FLANGE (FL) 1 - 2" BLOWOFF ASSEMBLY SEE YELM STD DWG. 4-9 SHEET C7.6 CONC. THRUST BLOCKING END WATER MAIN 1 - 4" CAP W/ 2" THREADED TAP (FL) 1 - 2" GATE FALVE W/ 2" THREADED FLANGE (FL) 1 - 2" BLOWOFF ASSEMBLY SEE YELM STD DWG. 4-9 SHEET C7.6 CONC. THRUST BLOCKING END WATER MAIN 1 - 8" CAP W/ 2" THREADED TAP (FL) 1 - 2" GATE FALVE W/ 2" THREADED FLANGE (FL) 1 - 2" BLOWOFF ASSEMBLY SEE YELM STD DWG. 4-9 SHEET C7.6 CONC. THRUST BLOCKING ALIGNMENT STATION, OFFSET ROAD 1 STA:2+84.45, 11.01' L ROAD 3 STA:0+52.59, 11.00' R ROAD 2 STA:0+33.73, 11.00' L WATER METER TABLE LOT/S LOT 41 & 109 LOT 42 & 43 LOT 44 LOT 45 & 46 LOT 47 & 48 LOT 49 & 50 LOT 51 & 52 LOT 53 & 54 DESCRIPTION DUAL METER DUAL METER SINGLE METER DUAL METER DUAL METER DUAL METER DUAL METER DUAL METER ALIGNMENT STATION OFFSET ROAD 2 STA:2+88.72, 22.50' R ROAD 2 STA:1+88.72, 22.50' R ROAD 2 STA:0+95.28, 39.23' R ROAD 2 STA:1+85.82, 22.50' L ROAD 2 STA:2+85.82, 22.50' L ROAD 2 STA:3+77.96, 22.50' L ROAD 2 STA:4+61.96, 22.78' L ROAD 2 STA:5+56.77, 22.50' L s s s s 2 1TRACT 'L'3 4 3+002+00 STA: 1+01.14 ROAD 1= STA: 11+82.62 JACKSON WA3 FH7 LOT 1 LOT 2 & 3 3 6 4 37 6 LOT 4 & 5 WF24 WF25 WF26 s sss s s s s s s ssss s s s s s s s s s s s s s s 51 50 49 108 106 105 53 54 42 41 46 47 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 52 40 2+0 0 3+0 0 4+00 5+00 6+00 7+00 STA: 7+06.91 ROAD 2= STA: 14+37.61 JACKSON WF31 WF32 FH8 LOT 55 LOT 44 LOT 108 LOT 40 LOT 104 & 105LOT 106 & 107 LOT 41 & 109 LOT 42 & 43 LOT 45 & 46 LOT 47 & 48 LOT 49 & 50 LOT 51 & 52 LOT 53 & 54 FH9 WA5 3 6 4 358 356 354 3 5 6 3 5 8 35 2 35 4 3 5 6 3 5 4 3 6 2 WF29 WF30 WF33 s s s s s s s ss s s s s 92 91 89 88 87 85 90 2+00 STA: 2+75.47 ROAD 3= STA: 5+15.77 BERRY VALLEY 4+ 0 0 5+ 0 0 6+ 0 0 LOT 90 LOT 86 & 87 LOT 88 & 89 35 8 356 36 6 36 4 36 2 36 0 358 3 6 8 3 6 4 3 6 6 WF3 WF4 LOT 91 & 92 LOT 84 & 85 N 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR.dwg C7.5 45 ROAD 1, ROAD 2 & ROAD 3 WATER PLAN & PROFILE ROAD 1 PROFILE HORIZ. 1"=50', VERT. 1"=5' SEE C7.4 SE E C7. 4 SEE C7.4 ROAD 3 JA C K S O N ROAD 3 - LOCAL ACCESS RESIDENTIAL 1"=50' ROAD 1 - LOCAL ACCESS RESIDENTIAL 1"=50' SEE C7.1 SEE C7.1 ROAD 2 - LOCAL ACCESS RESIDENTIAL 1"=50' SEE C7.4 ROAD 2 PROFILE HORIZ. 1"=50', VERT. 1"=5' ROAD 3 PROFILE HORIZ. 1"=50', VERT. 1"=5' BE R R Y V A L L E Y J A C K S O N ROAD 2 ROAD 1 N N 86 354.36 347.94 348.30 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: May 13, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR-DETL.dwg C7.6 46 WATER NOTES & DETAILS 1.ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION. 2.ALL WORK IN CITY RIGHT-OF-WAY REQUIRES A PERMIT FROM THE CITY OF YELM. PRIOR TO ANY WORK COMMENCING, THE GENERAL CONTRACTOR SHALL ARRANGE FOR A PRECONSTRUCTION MEETING TO BE ATTENDED BY ALL MAJOR CONTRACTORS, REPRESENTATIVES OF INVOLVED UTILITIES, AND THE CITY OF YELM. THE CONTRACTOR IS RESPONSIBLE TO HAVE A SET OF APPROVED PLANS AT THE MEETING. 3.WATER MAINS SHALL MEET THE FOLLOWING SPECIFICATIONS: 3.1.POLYVINYL CHLORIDE (PVC) PIPE (UNDER 4 INCHES): PIPE MATERIAL SHALL BE PVC 1120, PVC 1220, OR PVC 2120, AND HAVE MINIMUM WALL THICKNESS EQUAL TO OR LESS THAN THE STANDARD DIMENSION RATIO (SDR) OF 21, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)B. 3.2.POLYVINYL CHLORIDE (PVC) PIPE (4 THROUGH 12 INCHES): SHALL MEET THE REQUIREMENTS OF AWWA C900, CLASS 150 WALL THICKNESS EQUAL TO OR GREATER THAN THE SDR OF 18, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)A. 3.3.POLYVINYL CHLORIDE (PVC) PIPE (14 THROUGH 20 INCHES): SHALL MEET THE REQUIREMENTS OF AWWA C905 WALL THICKNESS EQUAL TO OR GREATER THAN THE SDR OF 18. 3.4.DUCTILE IRON PIPE (DIP): DIP SHALL CONFORM TO AWWA C151 CLASS 50 OR GREATER, AND SHALL BE 1/16-INCH CEMENT LINED AND SEALED IN ACCORDANCE WITH ANSI/AWWA C104/A21.4-90, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9- 30.2.(1). SIX-INCH FIRE HYDRANT SPOOLS SHALL BE CLASS 52. 4.GATE VALVES SHALL BE RESILIENT WEDGE, NRS (NON RISING STEM) WITH O-RINGS SEALS. VALVE ENDS SHALL BE MECHANICAL JOINT OR ANSI FLANGES. VALVES SHALL CONFORM TO AWWA 509-80. VALVES SHALL BE MUELLER, M & H, KENNEDY, CLOW R/W OR WATEROUS SERIES 500. EXISTING VALVES TO BE OPERATED BY CITY EMPLOYEES ONLY. 5.HYDRANTS SHALL BE M & H RELIANT STYLE 929, MUELLER CENTURION, OR CLOW MEDALLION OR AVK. HYDRANTS SHALL BE BAGGED UNTIL SYSTEM IS APPROVED. FIRE FLOW TESTING SHALL BE CONDUCTED PRIOR TO ACCEPTANCE. 6.ALL LINES SHALL BE CHLORINATED AND TESTED IN CONFORMANCE WITH THE ABOVE REFERENCED SPECIFICATION (NOTE 1). 7.ALL PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" TO 18" UNDER THE FINAL GROUND SURFACE. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED WATER 2-INCH-WIDE MINIMUM, WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. IN ADDITION TO TRACER TAPE, INSTALL 14 GAUGE HEAVY DUTY DIRECT BURY COATED COPPER WIRE (PAIGE "UF" SINGLE CONDUCTOR OR EQUAL), WRAPPED AROUND THE PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY. ALL WIRE CONNECTIONS SHALL USE WIRE NUTS AND A DBR SPLICE KIT, MANUFACTURED BY 3-M OR APPROVED EQUAL. ALL LOCATOR WIRE FOR SERVICE PIPE SHALL BE CONNECTED TO THE LOCATOR WIRE ON THE WATER MAIN. 8.PROVIDE TRAFFIC CONTROL PLAN(S) AS REQUIRED IN ACCORDANCE WITH MUTCD. 9.ALL WATER MAINS SHALL BE STAKED FOR GRADES AND ALIGNMENT BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK. 10.ALL SERVICE LINE LOCATIONS SHALL BE MARKED ON THE FACE OF THE CURB WITH AN EMBOSSED "W" 1/4 INCH INTO CONCRETE. 11.CALL UNDERGROUND LOCATE AT 1-800-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATIONS. 12.THE CITY WILL BE GIVEN 72 HOURS NOTICE PRIOR TO SCHEDULING A SHUTDOWN. WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", CONNECTION POINTS WILL BE EXPOSED BY CONTRACTOR AND FITTINGS VERIFIED 48 HOURS PRIOR TO DISTRIBUTING SHUT-DOWN NOTICES. 13.AT ANY CONNECTION TO AN EXISTING LINE WHERE A NEW VALVE IS NOT INSTALLED, THE EXISTING VALVE MUST BE PRESSURE TESTED TO CITY STANDARDS PRIOR TO CONNECTION. IF AN EXISTING VALVE FAILS TO PASS THE TEST, THE CONTRACTOR SHALL MAKE THE NECESSARY PROVISIONS TO TEST THE NEW LINE PRIOR TO CONNECTION TO THE EXISTING SYSTEM OR INSTALL A NEW VALVE. 14.AFTER COMPLETION OF ALL ITEMS SHOWN ON THESE PLANS AND BEFORE ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL OBTAIN A “PUNCH LIST” PREPARED BY THE CITY’S INSPECTOR DETAILING REMAINING ITEMS OF WORK TO BE COMPLETED. ALL ITEMS OF WORK SHOWN ON THESE PLANS SHALL BE COMPLETED TO THE SATISFACTION OF THE CITY PRIOR TO ACCEPTANCE OF THE WATER SYSTEM AND PROVISION OF WATER SERVICE. 15.A COPY OF THESE APPROVED PLANS AND APPLICABLE CITY DEVELOPER SPECIFICATIONS AND DETAILS SHALL BE ONSITE DURING CONSTRUCTION. 16.ANY REVISIONS MADE TO THESE PLANS MUST BE REVIEWED BY THE DEVELOPER’S ENGINEER AND THE CITY OF YELM PRIOR TO ANY IMPLEMENTATION IN THE FIELD. THE CITY SHALL NOT BE RESPONSIBLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE PLANS. GENERAL NOTES (WATER MAIN INSTALLATION) 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: May 13, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WATR-DETL.dwg C7.7 47 WATER NOTES & DETAILS 10/09/2024 929394 84 69 61 68 60 6766 656463 70 62 2 71 83 72 8 0 TRACT 'B' 8 2 8 1 TRACT 'A' 7 9 7 6 7 7 7 8 7 4 7 5 7 3 1 59 91 89 88 87 85 97 8690 TRACT 'L' 104 55 TR A C T ' D ' TR A C T ' C ' 3 102 100 99 9596 103 98 101 s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 3+003+00 7+00 2+00 3+00 4+00 5+00 6+00 7+00 8 + 0 0 9 + 0 0 1 0 + 0 0 1 1 + 0 0 12+00 13 + 0 0 1 3 + 0 0 1 4 + 0 0 1 5 + 0 0 16 + 0 0 17 + 0 0 STA: 1+01.14 ROAD 1= STA: 11+82.62 JACKSON 2.5" SEWER STEP MAIN 254LF 2.5" PVC SDR-21 167LF 2.5" PVC SDR-21 2.5" SEWER STEP MAIN STA:2+39.45, 11.00' R END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 STA: 5+15.77 BERRY VALLEY= STA: 2+75.47 ROAD 3 STA: 1+04.80 11.00' LT 1 - 2" x 1.5" REDUCER 1.5" SEWER STEP MAIN STA: 9+44.12 11.00' RT 1 - 2" x 1.5" REDUCER STA: 5+42.50 11.00' RT 1 - 2.5" x 2" REDUCER STA: 10+27.62 11.00' RT END SEWER STEP MAIN PROVIDE END OF LINE CLEANOUT PER YELM DWG. NO. 5-20 ON SHEET C8.5 1.5" SEWER STEP MAIN 2" SEWER STEP MAIN STA:5+04.75 1 - 2.5" TEE 2 - 2.5" GATE VALVE (E,W) 1 - 2.5"x2" REDUCER (S) 1 - 2" GATE VALVE (S) CONC. THRUST BLOCKING STA:14+30.11 1 - 2.5" TEE 2 - 2.5" GATE VALVE (N,S) 1 - 2.5"x2" REDUCER (W) 1 - 2" GATE VALVE (W) CONC. THURST BLOCKING Profile View of BERRY VALLEY26 BERRY VALLEY 340 345 350 355 360 365 370 375 340 345 350 355 360 365 370 375 320 325 330 335 340 345 350 355 320 325 330 335 340 345 350 355 35 0 . 4 9 1+50 35 0 . 2 0 35 0 . 3 6 2+00 35 0 . 9 5 35 1 . 9 9 2+50 35 3 . 2 4 35 4 . 4 9 3+00 35 5 . 6 5 35 6 . 6 3 3+50 35 7 . 4 3 35 8 . 0 5 4+00 35 8 . 4 9 35 8 . 7 5 4+50 35 8 . 8 3 35 8 . 7 4 5+00 35 8 . 4 6 35 8 . 0 0 5+50 35 7 . 3 6 35 6 . 5 5 6+00 35 5 . 5 5 35 4 . 3 8 6+50 35 3 . 0 2 35 1 . 4 9 34 8 . 2 4 7+50 34 6 . 6 1 34 4 . 9 9 8+00 34 3 . 3 6 34 1 . 8 3 8+50 34 0 . 4 8 33 9 . 3 1 9+00 33 8 . 3 3 33 7 . 5 3 9+50 33 6 . 9 2 33 6 . 4 0 10+00 33 5 . 8 8 33 5 . 3 5 10+50 33 4 . 8 3 33 4 . 3 1 11+00 33 3 . 7 9 33 3 . 2 7 11+50 33 2 . 7 4 33 2 . 2 2 PROPOSED 12" STORM PROPOSED WATER MAIN STA: 5+04.77 1 - 2.5" TEE 2 - 2.5" GATE VALVE 1 - 2.5"x2" REDUCER 1 - 2" GATE VALVE CONC. THRUST BLOCKING 1 - 2.5" x 2" REDUCER 1 - 2" x 1.5" REDUCER STA: 10+27.62 END SEWER STEP MAIN PROVIDE END OF LINE CLEANOUT PER YELM DWG. NO. 5-20 ON SHEET C8.5 2.00% 5.00% 6. 5 0 % 2.09% PC 7+ 0 8 . 7 3 EL E V = 3 4 9 . 2 9 PT 8+ 3 6 . 1 3 EL E V = 3 4 1 . 2 0 PC 10 + 4 6 . 3 4 EL E V = 3 3 4 . 9 1 PT 11 + 7 6 . 2 8 EL E V = 3 3 2 . 2 0 421L F 2 . 5 " P V C S D R - 2 1 33LF 2.5" PVC SDR-21 392LF 2" PVC SDR-21 84LF 1.5" PVC SDR-21 SEWER STUB TABLE STUB NAME LOT 71 & 72 LOT 73 & 74 LOT 75 & 76 LOT 77 & 78 LOT 79 LOT 80 LOT 81 & 82 LOT 83 LOT 84 LOT 85 LOT 96 STUB INFORMATION STA: 7+20.16, 17.09' L 2" DUAL SERVICE CONNECTION STA: 7+83.15, 17.09' L 2" DUAL SERVICE CONNECTION STA: 8+64.12, 17.09' L 2" DUAL SERVICE CONNECTION STA: 9+44.12, 17.09' L 2" DUAL SERVICE CONNECTION STA: 10+22.62, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 9+69.92, 19.50' R 1" SINGLE SERVICE CONNECTION STA: 8+81.42, 17.09' R 2" DUAL SERVICE CONNECTION STA: 7+18.36, 19.49' R 1" SINGLE SERVICE CONNECTION STA: 6+46.52, 19.87' R 1" SINGLE SERVICE CONNECTION STA: 5+71.20, 19.86' R 1" SINGLE SERVICE CONNECTION STA: 2+34.77, 19.50' R 1" SINGLE SERVICE CONNECTION ROAD NAME BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY SEWER STUB TABLE STUB NAME LOT 59 LOT 60 LOT 61 & 62 LOT 63 & 64 LOT 65 LOT 66 STUB INFORMATION STA: 1+37.41, 22.84' L 1" SINGLE SERVICE CONNECTION STA: 1+93.00, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 2+64.00, 17.09' L 2" DUAL SERVICE CONNECTION STA: 3+44.00, 17.09' L 2" DUAL SERVICE CONNECTION STA: 4+24.25, 19.59' L 1" SINGLE SERVICE CONNECTION STA: 4+44.25, 19.51' L 1" SINGLE SERVICE CONNECTION ROAD NAME BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY SEWER STUB TABLE STUB NAME LOT 67 LOT 68 LOT 69 & 70 LOT 91 LOT 92 & 93 LOT 94 & 95 STUB INFORMATION STA: 5+32.00, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 5+42.50, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 6+34.00, 17.09' L 2" DUAL SERVICE CONNECTION STA: 4+68.91, 19.86' R 1" SINGLE SERVICE CONNECTION STA: 3+94.29, 17.35' R 2" DUAL SERVICE CONNECTION STA: 3+14.14, 17.35' R 2" DUAL SERVICE CONNECTION ROAD NAME BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY BERRY VALLEY N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-SSWR.dwg C8.1 48 BERRY VALLEY ROAD STEP PLAN & PROFILE BERRY VALLEY ROAD SE PROFILE (STA. 1+00 - STA. 13+50) HORIZ. 1"=50', VERT. 1"=5' BERRY VALLEY ROAD SE PLAN - NEIGHBORHOOD COLLECTOR (STA. 1+00 - STA. 13+50) 1"=50' BERRY VALLEY ROAD SE EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD SEE C8.4SEE C8.3 SEE C8.3 RO A D 3 JA C K S O N ST S E 1.SEE CITY OF YELM DWG. NO. 5-1 ON SHEET C8.5 FOR 1" SINGLE SERVICE CONNECTION. 2.SEE CITY OF YELM DWG. NO. 5-2 ON SHEET C8.5 FOR 2" DOUBLE SERVICE CONNECTION. SEWER STUB NOTES EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD SEWER STEP MAIN SIZING BERRY VALLEY ROAD SE (STA: 0+94 TO STA: 5+43) NUMBER OF PUMP CORES CONNECTED:38 MAX. PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):6 PROPOSED STEP MAIN SIZE:2.5" FLOW VELOCITY (TABLE 5):3.99 fps FRICTION HEAD LOSS (TABLE 5):2.2 FT/100FT BERRY VALLEY ROAD SE (STA: 5+43 TO 9+44) NUMBER OF PUMP CORES CONNECTED:18 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):4 PROPOSED STEP MAIN SIZE:2" FLOW VELOCITY (TABLE 5):3.89 fps FRICTION HEAD LOSS (TABLE 5):2.63 FT/100FT BERRY VALLEY ROAD SE (STA: 9+44 TO 10+28) NUMBER OF PUMP CORES CONNECTED:2 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):2 PROPOSED STEP MAIN SIZE:1.5" FLOW VELOCITY (TABLE 5):3.47 fps FRICTION HEAD LOSS (TABLE 5):2.97 FT/100FT *FORCE MAIN DESIGN PERFORMED USING RECOMMENDATIONS IN THE 'DESIGN HANDBOOK FOR LOW PRESSURE SEWER SYSTEMS' PREPARED BY ENVIRONMENT ONE. 10/09/2024 JACKSON ST SE 25 24 21 22 18 23 38 14 15 36 37 35 34 33 20 19 16 17 13 12 11 27 26 39 40 32 s s s s s s s s s s s s s s s s s s s s s s s s s ss s 1+00 2+00 3+00 4+00 5+00 6 + 0 0 7 + 0 0 8 + 0 0 9+00 STA:2+20.65 CONNECT TO EXISTING 4" SEWER STEP SYSTEM 1-4"x3" REDUCER 3" S E W E R S T E P M A I N 355 360 365 370 375 380 385 390 395 355 360 365 370 375 380 385 390 395 1+00 1+50 2+00 38 0 . 9 3 2+50 38 1 . 7 7 38 2 . 2 5 3+00 38 2 . 2 9 38 1 . 8 8 3+50 38 1 . 0 3 37 9 . 8 1 4+00 37 8 . 5 6 37 7 . 3 1 4+50 37 6 . 0 6 37 4 . 8 1 5+00 37 3 . 5 6 37 2 . 3 2 5+50 37 1 . 2 0 37 0 . 2 5 6+00 36 9 . 4 7 36 8 . 8 5 6+50 36 8 . 4 0 36 8 . 1 1 7+00 36 7 . 8 6 36 7 . 6 1 7+50 36 7 . 3 6 36 7 . 1 1 8+00 36 6 . 8 5 36 6 . 6 0 8+50 36 6 . 3 5 36 6 . 1 0 9+00 36 5 . 8 5 PROPOSED WATER MAIN PROPOSED 12" STORMSTA: 2+20.65 CONNECT TO EXISTING 4" SEWER STEP SYSTEM 1-4"x3" REDUCER 12" STORM BOT 366.23 12" STORM BOT 363.81 3.50% 5.0 0 % 1.00% GRADE BREAK STA: 2+09.43 ELEV: 380.39 42 5 L F 3 " P V C S D R - 2 1 SEWER STUB TABLE STUB NAME LOT 11 & 12 LOT 13 & 14 LOT 15 & 16 LOT 17 & 18 LOT 19 LOT 20 & 21 LOT 22 & 23 LOT 24 LOT 25 & 26 LOT 27 & 28 LOT 29 & 30 LOT 31 & 32 LOT 33 & 34 LOT 35 & 36 LOT 37 & 38 STUB INFORMATION STA: 8+62.72, 4.60' L 2" DUAL SERVICE CONNECTION STA: 7+81.54, 8.59' L 2" DUAL SERVICE CONNECTION STA: 7+00.32, 0.01' R 2" DUAL SERVICE CONNECTION STA: 6+16.38, 20.58' R 2" DUAL SERVICE CONNECTION STA: 4+72.09, 22.11' R 1" SINGLE SERVICE CONNECTION STA: 3+69.77, 19.97' R 2" DUAL SERVICE CONNECTION STA: 3+14.28, 19.97' R 2" DUAL SERVICE CONNECTION STA: 2+41.30, 19.41' R 1" SINGLE SERVICE CONNECTION STA: 2+78.26, 20.09' L 2" DUAL SERVICE CONNECTION STA: 4+23.20, 20.37' L 2" DUAL SERVICE CONNECTION STA: 5+06.28, 19.60' L 2" DUAL SERVICE CONNECTION STA: 5+91.67, 16.65' L 2" DUAL SERVICE CONNECTION STA: 6+81.68, 37.28' L 2" DUAL SERVICE CONNECTION STA: 7+78.92, 48.71' L 2" DUAL SERVICE CONNECTION STA: 8+76.67, 43.27' L 2" DUAL SERVICE CONNECTION ROAD NAME JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-SSWR.dwg C8.2 49 JACKSON STREET STEP PLAN & PROFILE JACKSON STREET SE PROFILE (STA. 1+00 - STA. 9+00) HORIZ. 1"=50', VERT. 1"=5' JACKSON STREET SE PLAN - LOCAL ACCESS RESIDENTIAL (STA. 1+00 - STA. 9+00) 1"=50' J A C K S O N S T . S E EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD SEE C8.3 1.SEE CITY OF YELM DWG. NO. 5-1 ON SHEET C8.5 FOR 1" SINGLE SERVICE CONNECTION. 2.SEE CITY OF YELM DWG. NO. 5-2 ON SHEET C8.5 FOR 2" DOUBLE SERVICE CONNECTION. SEWER STUB NOTES SEWER STEP MAIN SIZING JACKSON STREET SE (STA: 2+21 TO STA: 11+80) NUMBER OF PUMP CORES CONNECTED:109 MAX. PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):8 PROPOSED STEP MAIN SIZE:3" FLOW VELOCITY (TABLE 5):3.59 fps FRICTION HEAD LOSS (TABLE 5):1.44 FT/100FT *FORCE MAIN DESIGN PERFORMED USING RECOMMENDATIONS IN THE 'DESIGN HANDBOOK FOR LOW PRESSURE SEWER SYSTEMS' PREPARED BY ENVIRONMENT ONE. 10/09/2024 106 105 53 54 56 57 61 60 58 2 59 97 38 TRACT 'L' 104 107 55 3 100 99 96 103 98 37 5 4 6 11 10 9 8 7 39 40 s s s s s s s sss s ss s s s s s s s s s s s ss s s s ss s s s 2 + 0 0 5+ 0 0 6+ 0 0 7+ 0 0 2+ 0 0 17+50 8 + 0 0 9+00 1 0 + 0 0 11+ 0 0 12+00 13+00 14+00 15+00 16+00 17+00 STA: 1+01.14 ROAD 1= STA: 11+82.62 JACKSON STA:17+27.86 END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 STA: 16+60.86 11.00' LT 1 - 2" x 1.5" REDUCER STA: 7+06.91 ROAD 2= STA: 14+37.61 JACKSON 2 " S E W E R S T E P M A I N STA:11+83.09 1 - 2.5" TEE 1 - 3"x2.5" REDUCER (S) 2 - 2.5" GATE VALVE (S,N) 1 - 2.5"x2" REDUCER (E) 1 - 2" GATE VALVE (E) CONC. THURST BLOCKING STA:14+30.11 1 - 2.5" TEE 2 - 2.5" GATE VALVE (N,S) 1 - 2.5"x2" REDUCER (W) 1 - 2" GATE VALVE (W) CONC. THURST BLOCKING STA:15+95.86 1 - 2.5" TEE 2 - 2.5" GATE VALVE (S,E) 1 - 2.5"x2" REDUCER (N) 1 - 2" GATE VALVE (N) CONC. THRUST BLOCKING 335 340 345 350 355 360 365 370 375 380 335 340 345 350 355 360 365 370 375 380 EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD 9+00 36 5 . 8 5 36 5 . 6 0 9+50 36 5 . 3 5 36 5 . 1 0 10+00 36 4 . 8 5 36 4 . 6 0 10+50 36 4 . 3 5 36 4 . 1 2 11+00 36 4 . 0 3 36 4 . 0 9 11+50 36 4 . 3 1 36 4 . 6 7 12+00 36 4 . 9 3 36 4 . 8 3 12+50 36 4 . 4 0 36 3 . 9 0 13+00 36 3 . 4 0 36 2 . 9 0 13+50 36 2 . 4 0 36 1 . 9 0 14+00 36 1 . 4 0 36 0 . 7 8 14+50 35 9 . 9 0 35 8 . 7 8 15+00 35 7 . 4 0 35 5 . 9 0 15+50 35 4 . 4 0 35 2 . 9 0 16+00 35 1 . 4 0 35 0 . 0 0 16+50 34 8 . 7 8 34 7 . 7 5 17+00 34 6 . 9 0 17+50 PROPOSED 12" STORM STA: 17+28.07 END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 12" STORM BOT 360.54 12" STORM BOT 355.29 3.00 % 2.00% 6. 0 0 % 1.50%959 LF 3" PVC SDR-21 374LF 2.5" PVC SDR-21 445LF 2.5" PVC SDR-21 1 - 2.5" TEE 2 - 2.5" GATE VALVE (N,S) 1 - 2.5"x2" REDUCER (W) 1 - 2" GATE VALVE (W) CONC. THRUST BLOCKING 1 - 2.5" TEE 1 - 3"x2.5" REDUCER (S) 2 - 2.5" GATE VALVE (S,N) 1 - 2.5"x2" REDUCER (E) 1 - 2" GATE VALVE (E) CONC. THRUST BLOCKING 1 - 2.5" TEE 2 - 2.5" GATE VALVE (S,E) 1 - 2.5"x2" REDUCER (N) 1 - 2" GATE VALVE (N) CONC. THRUST BLOCKING 67LF 1.5" PVC SDR-21 65LF 2" PVC SDR-21 SEWER STUB TABLE STUB NAME LOT 3 LOT 4 LOT 5 & 6 LOT 7 & 8 LOT 9 & 10 LOT 39 & 40 LOT 56 LOT 57 LOT 58 LOT 59 LOT 97 LOT 98 LOT 99 & 100 LOT 103 LOT 104 STUB INFORMATION STA: 12+04.67, 49.58' R 1" SINGLE SERVICE CONNECTION STA: 1+08.12, 43.32' R 1" SINGLE SERVICE CONNECTION STA: 10+79.37, 15.66' R 2" DUAL SERVICE CONNECTION STA: 10+18.51, 14.10' R 2" DUAL SERVICE CONNECTION STA: 9+43.00, 9.71' R 2" DUAL SERVICE CONNECTION STA: 9+76.51, 26.99' L 2" DUAL SERVICE CONNECTION STA: 16+27.52, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 16+38.52, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 17+14.86, 19.50' L 1" SINGLE SERVICE CONNECTION STA: 1+37.41, 22.84' L 1" SINGLE SERVICE CONNECTION STA: 15+65.52, 16.51' R 1" SINGLE SERVICE CONNECTION STA: 14+92.99, 22.48' R 1" SINGLE SERVICE CONNECTION STA: 14+23.26, 20.02' R 2" DUAL SERVICE CONNECTION STA: 13+16.21, 22.27' R 1" SINGLE SERVICE CONNECTION STA: 6+64.11, 22.50' R 1" SINGLE SERVICE CONNECTION ROAD NAME JACKSON ROAD 1 JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON JACKSON BERRY VALLEY JACKSON JACKSON JACKSON JACKSON ROAD 2 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-SSWR.dwg C8.3 50 JACKSON STREET STEP PLAN & PROFILE JACKSON STREET SE PROFILE (STA. 9+00 - STA. 17+50) HORIZ. 1"=50', VERT. 1"=5' JACKSON STREET SE PLAN - LOCAL ACCESS RESIDENTIAL (STA. 9+00 - STA. 17+50) 1"=50' JACKSON ST. SE END ROAD CONSTRUCTION MATCH EXISTING R O A D 1 RO A D 2 BE R R Y VA L L E Y SEE C8.2 SEE C8.4 SEE C8.1 SEE C8.4 1.SEE CITY OF YELM DWG. NO. 5-1 ON SHEET C8.5 FOR 1" SINGLE SERVICE CONNECTION. 2.SEE CITY OF YELM DWG. NO. 5-2 ON SHEET C8.5 FOR 2" DOUBLE SERVICE CONNECTION. SEWER STUB NOTESSEWER STEP MAIN SIZING JACKSON STREET SE (STA: 2+21 TO STA: 11+80) NUMBER OF PUMP CORES CONNECTED:109 MAX. PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):8 PROPOSED STEP MAIN SIZE:3" FLOW VELOCITY (TABLE 5):3.59 fps FRICTION HEAD LOSS (TABLE 5):1.44 FT/100FT JACKSON STREET SE (STA: 11+80 TO STA: 16+01) NUMBER OF PUMP CORES CONNECTED:70 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):7 PROPOSED STEP MAIN SIZE:2.5" FLOW VELOCITY (TABLE 5):4.65 fps FRICTION HEAD LOSS (TABLE 5):2.93 FT/100FT JACKSON STREET SE (STA: 16+01 TO STA: 17+28) NUMBER OF PUMP CORES CONNECTED:3 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):2 PROPOSED STEP MAIN SIZE:1.5" FLOW VELOCITY (TABLE 6):3.47 fps FRICTION HEAD LOSS (TABLE 6):2.97 FT/100FT *FORCE MAIN DESIGN PERFORMED USING RECOMMENDATIONS IN THE 'DESIGN HANDBOOK FOR LOW PRESSURE SEWER SYSTEMS' PREPARED BY ENVIRONMENT ONE. 1 - 2"X1.5" REDUCER 3" SSFM 2.5" SSFM 2" SSFM 2" SSFM 2.5" SSFM 2" SSFM 1.5" SSFM 2.5" SSFM 10/09/2024 s s s s s 2+00 3+003+00 3 6 4 3 7 6 3 7 0 3 6 8 STA: 1+01.14 ROAD 1= STA: 11+82.62 JACKSON STA:2+39.45, 11.00' R END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 2" SEWER STEP M A I N STA:0+90.29 1 - 2.5" TEE 1 - 3"x2" REDUCER (E) 2 - 2.5" GATE VALVE (N,S) 1 - 2.5"x2" REDUCER (E) 1 - 2" GATE VALVE (E) CONC. THURST BLOCKING 355 360 365 370 375 380 355 360 365 370 375 380 EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD 0+50 36 4 . 6 7 1+00 36 4 . 7 5 36 4 . 4 0 1+50 36 4 . 4 9 36 5 . 1 1 2+00 36 6 . 2 2 36 7 . 4 2 2+50 36 8 . 6 2 36 9 . 8 2 3+00 2.00% 4.80% PROPOSED 12" STORM PROP O S E D W A T E R M A I N STA: 2+39.45 END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD 108L F 2 " P V C S D R - 2 1 1 - 2.5" TEE 1 - 3"x2.5" REDUCER (S) 2 - 2.5" GATE VALVE (S,N) 1 - 2.5"x2" REDUCER (E) 1 - 2" GATE VALVE (E) 51 50 49 108 106 105 53 54 42 41 46 47 97 TRACT 'L' 104107 109 43 48 55 45 TRACT 'H' 44 52 3 100 99 103 98 4 s sss s s s s s s ssss s s s s s s s s s s s s s s s 2+0 0 3+0 0 4+00 5+00 6+00 7+00 3 6 4 3 6 2 360 358 356 354 3 5 6 3 5 8 35 2 35 4 3 5 6 3 5 4 352 354 STA: 1+01.14 ROAD 1= STA: 11+82.62 JACKSON STA:0+56.85, 10.88' R END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 2" SEWER STEP M A I N 2" S E W E R S T E P M A I N STA: 7+06.91 ROAD 2= STA: 14+37.61 JACKSON STA:6+97.00 1 - 2.5" TEE 2 - 2.5" GATE VALVE (N,S) 1 - 2.5"x2" REDUCER (W) 1 - 2" GATE VALVE (W) CONC. THRUST BLOCKING STA:0+90.29 1 - 2.5" TEE 1 - 3"x2" REDUCER (E) 2 - 2.5" GATE VALVE (N,S) 1 - 2.5"x2" REDUCER (E) 92 84 91 89 88 87 85 86 90 s s s s s s s s s ss s s s s 2+00 4+ 0 0 5+ 0 0 6+ 0 0 35 8 356 354 36 6 36 4 36 2 36 0 358 3 6 8 3 6 6 3 7 0 3 6 8 STA:0+56.95, 10.97' L END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 STA: 2+75.47 ROAD 3= STA: 5+15.77 BERRY VALLEY STA: 1+04.80 11.00' LT 1 - 2" x 1.5" REDUCER 1.5" SEWER STEP MAIN 2" SEWER STEP MAIN STA:2+64.47 1 - 2.5" TEE 2 - 2.5" GATE VALVE (E,W) 1 - 2.5"x2" REDUCER (S) 1 - 2" GATE VALVE (S) CONC. THRUST BLOCKING 340 345 350 355 360 365 340 345 350 355 360 365 EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD 0+50 35 0 . 9 7 1+00 35 1 . 2 2 35 1 . 4 7 1+50 35 1 . 7 2 35 1 . 9 7 2+00 35 2 . 2 2 35 2 . 4 7 2+50 35 2 . 7 2 35 2 . 9 7 3+00 35 3 . 2 2 35 3 . 4 7 3+50 35 3 . 7 2 35 4 . 0 0 4+00 35 4 . 3 5 35 4 . 7 5 4+50 35 5 . 2 2 35 5 . 7 2 5+00 35 6 . 2 2 35 6 . 7 2 5+50 35 7 . 2 2 35 7 . 7 2 6+00 35 8 . 2 2 35 8 . 7 2 6+50 35 9 . 2 2 35 9 . 7 2 7+00 36 0 . 2 2 7+50 PROPOSED 12" STORM PROPOSED WATE R M A I N 1 - 2.5" TEE 2 - 2.5" GATE VALVE 1 - 2.5"x2" REDUCER 1 - 2" GATE VALVE CONC. THRUST BLOCKING STA: 0+56.83 END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 1.00% 2.00% GRADE BREAK STA: 0+75.00 ELEV: 350.97 GRADE BREAK STA: 7+06.91 ELEV: 360.36 PT 1+ 6 1 . 3 7 EL E V = 3 5 1 . 8 4 PC 3+ 2 8 . 7 0 EL E V = 3 5 3 . 5 1 PT 4+ 8 5 . 3 0 EL E V = 3 5 5 . 9 3 EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD 634LF 2" P V C S D R - 2 1 345 350 355 360 365 370 345 350 355 360 365 370 EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD EXISTING GRADE @ CL OF ROAD FINISHED GRADE @ CL OF ROAD 0+50 36 7 . 1 6 36 6 . 1 9 1+00 36 4 . 6 9 36 3 . 1 9 1+50 36 1 . 6 9 36 0 . 1 9 2+00 35 8 . 7 7 35 7 . 9 4 2+50 35 7 . 8 0 35 8 . 1 8 3+00 35 8 . 4 7 2.00% 6. 0 0 % PROPOSED 12" STORM PROPOSED WATER MAIN 1 - 2.5" TEE 2 - 2.5" GATE VALVE 1 - 2.5"x2" REDUCER 1 - 2" GATE VALVE CONC. THRUST BLOCKING STA: 0+56.83 END OF FORCE MAIN PROVIDE END OF LINE CLEANOUT PER YELM DW 5-20 ON SHEET C8.5 16 4 L F 2 " P V C S D R - 2 1 48LF 1.5" PVC SCH-40 SEWER STUB TABLE STUB NAME LOT 41 & 42 LOT 43 & 44 LOT 45 LOT 46 & 47 LOT 48 & 49 LOT 50 & 51 LOT 52 & 53 LOT 54 & 55 LOT 104 LOT 105 & 106 STUB INFORMATION STA: 2+38.72, 20.09' R 2" DUAL SERVICE CONNECTION STA: 1+40.81, 21.00' R 2" DUAL SERVICE CONNECTION STA: 1+49.24, 23.57' L 1" SINGLE SERVICE CONNECTION STA: 2+35.82, 20.09' L 2" DUAL SERVICE CONNECTION STA: 3+34.84, 20.09' L 2" DUAL SERVICE CONNECTION STA: 4+21.09, 20.09' L 2" DUAL SERVICE CONNECTION STA: 5+06.79, 20.09' L 2" DUAL SERVICE CONNECTION STA: 6+06.79, 20.09' L 2" DUAL SERVICE CONNECTION STA: 6+64.11, 22.50' R 1" SINGLE SERVICE CONNECTION STA: 5+72.74, 20.09' R 2" DUAL SERVICE CONNECTION ROAD NAME ROAD 2 ROAD 2 ROAD 2 ROAD 2 ROAD 2 ROAD 2 ROAD 2 ROAD 2 ROAD 2 ROAD 2 SEWER STUB TABLE STUB NAME LOT 107 & 108 LOT 109 STUB INFORMATION STA: 4+69.61, 20.09' R 2" DUAL SERVICE CONNECTION STA: 3+37.06, 22.50' R 1" SINGLE SERVICE CONNECTION ROAD NAME ROAD 2 ROAD 2 SEWER STUB TABLE STUB NAME LOT 85 LOT 86 LOT 87 LOT 88 LOT 89 & 90 LOT 91 STUB INFORMATION STA: 5+71.20, 19.86' R 1" SINGLE SERVICE CONNECTION STA: 1+36.99, 25.56' R 1" SINGLE SERVICE CONNECTION STA: 0+66.68, 28.12' R 1" SINGLE SERVICE CONNECTION STA: 0+61.48, 23.19' L 1" SINGLE SERVICE CONNECTION STA: 1+05.59, 36.70' L 2" DUAL SERVICE CONNECTION STA: 4+68.91, 19.86' R 1" SINGLE SERVICE CONNECTION ROAD NAME BERRY VALLEY ROAD 3 ROAD 3 ROAD 3 ROAD 3 BERRY VALLEY SEWER STUB TABLE STUB NAME LOT 1 & 2 LOT 3 LOT 4 STUB INFORMATION STA: 2+34.45, 21.09' L 2" DUAL SERVICE CONNECTION STA: 12+04.67, 49.58' R 1" SINGLE SERVICE CONNECTION STA: 1+08.12, 43.32' R 1" SINGLE SERVICE CONNECTION ROAD NAME ROAD 1 JACKSON ROAD 1 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: October 8, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-SSWR.dwg C8.4 51 ROAD1, ROAD 2, & ROAD 3 STEP PLAN & PROFILE ROAD 1 PROFILE HORIZ. 1"=50', VERT. 1"=5' SEE C8.3 SEE C8.3 SEE C8.3 ROAD 3 J A C K S O N ROAD 3 - LOCAL ACCESS RESIDENTIAL 1"=50' ROAD 1 - LOCAL ACCESS RESIDENTIAL 1"=50' SEE C8.1 SEE C8.1 ROAD 2 - LOCAL ACCESS RESIDENTIAL 1"=50' SEE C8.3 ROAD 2 PROFILE HORIZ. 1"=50', VERT. 1"=5'ROAD 3 PROFILE HORIZ. 1"=50', VERT. 1"=5' BE R R Y V A L L E Y J A C K S O N ROAD 2 ROAD 1 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1.SEE CITY OF YELM DWG. NO. 5-1 ON SHEET C8.5 FOR 1" SINGLE SERVICE CONNECTION. 2.SEE CITY OF YELM DWG. NO. 5-2 ON SHEET C8.5 FOR 2" DOUBLE SERVICE CONNECTION. SEWER STUB NOTES SEWER STEP MAIN SIZING ROAD 1 NUMBER OF PUMP CORES CONNECTED:2 MAX. PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):2 PROPOSED STEP MAIN SIZE:2" FLOW VELOCITY (TABLE 5):1.95 fps FRICTION HEAD LOSS (TABLE 5):0.73 FT/100FT ROAD 2 NUMBER OF PUMP CORES CONNECTED:21 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):5 PROPOSED STEP MAIN SIZE:2" FLOW VELOCITY (TABLE 5):4.87 fps FRICTION HEAD LOSS (TABLE 5):3.97 FT/100FT ROAD 3 (STA: 1+05 TO STA: 2+69) NUMBER OF PUMP CORES CONNECTED:5 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):3 PROPOSED STEP MAIN SIZE:2" FLOW VELOCITY (TABLE 5):2.92 fps FRICTION HEAD LOSS (TABLE 5):1.54 FT/100FT *FORCE MAIN DESIGN PERFORMED USING RECOMMENDATIONS IN THE 'DESIGN HANDBOOK FOR LOW PRESSURE SEWER SYSTEMS' PREPARED BY ENVIRONMENT ONE. ROAD 3 (STA: 0+57 TO STA: 1+05) NUMBER OF PUMP CORES CONNECTED:2 PUMP CORES RUNNING SIMULTANEOUSLY (TABLE 3):2 PROPOSED STEP MAIN SIZE:1.5" FLOW VELOCITY (TABLE 6):3.47 fps FRICTION HEAD LOSS (TABLE 6):2.97 FT/100FT 1 - 2" x 1.5" REDUCER 4 123 10/09/2024 s s 40.00'40.00' 93 92 TYPICAL DOUBLE SERVICE VALVE BOX CONNECTION 6.50' LANDSCAPE BUFFER 5.00' SIDEWALK 5.00' SIDE SETBACK (TYP.) 10.00' UTILITY EASEMENT 20.00' DRIVEWAY 20.00' DRIVEWAY 1" SERVICE 25.00' FRONT SETBACK BERRY VALLEY RD SEWER CLEANOUT MIN 2.5' FROM STRUCTURE 5.00' MIN. 5.00' MIN, 2.00' MIN. 2" SERVICE LINE 5.00' MIN. 5.00' MIN. 5.00' SIDE SETBACK (TYP.) SEWER CLEANOUT MIN 2.5' FROM STRUCTURE 1,500 GAL. CONCRETE STEP TANK. SEE YELM DWG 5-9 ON SHEET C8.6 PRELOS 1,500 GAL. STEP TANK (8' DIA.), SEE CUT SHEET C8.6 2' MIN. 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: May 30, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-SSWR-DETL.dwg C8.5 52 SEWER STEP NOTES AND DETAILS CONCEPTUAL LAYOUT TANK UNDER DRIVEWAY NOTES: 1.THIS TYPICAL STEP LOCATION PLAN IS CONCEPTUAL ONLY. ACTUAL LOCATIONS AND SIZES OF SEPTIC TANKS MAY VARY. 2.STEP PIPELINES CONSTRUCTED AND SIZED WITHIN PRIVATE DEVELOPMENTS AND PUBLIC RIGHT-OF-WAY SHALL CONFORM TO THE CITY OF YELM SEWER COMPREHENSIVE PLAN AND THE DOE DESIGN MANUAL. 3.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION AND THE ELEVATION OF ALL EXISTING SEWER LINES PRIOR TO INSTALLING THE INDIVIDUAL TANK. STEP TANKS SHALL BE LOCATED IN FRONT OF BUILDING UNLESS OTHERWISE APPROVED BY THE CITY OF YELM. 4.IT IS ANTICIPATED THAT EXISTING UTILITY LINES WILL BE ENCOUNTERED DURING INSTALLATION OF THE STEP TANK AND APPURTENANCES. PRIOR TO STARTING CONSTRUCTION THE CONTRACTOR WILL NOTIFY THE PROPER UTILITY FOR UNDERGROUND LOCATIONS AND ALSO CONTACT THE PROPERTY OWNER TO DETERMINE LOCATION OF FOUNDATION DRAINS, ELECTRICAL LINES, ETC. N GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 CONCEPTUAL LAYOUT TANK OUTSIDE OF DRIVEWAY 1 NOT TO SCALE TYPICAL STEP TANK LOCATIONS 10/09/2024 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: May 30, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-SSWR-DETL.dwg C8.6 53 SEWER STEP NOTES AND DETAILS 1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION (WSDOT/APWA). 2.ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM SHALL BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 3.IF CONSTRUCTION IS TO TAKE PLACE IN THE CITY RIGHT-OF-WAY, THE CONTRACTOR SHALL NOTIFY THE CITY AND OBTAIN ALL THE REQUIRED APPROVALS AND PERMITS. 4.A PRECONSTRUCTION MEETING SHALL BE HELD WITH THE CITY OF YELM PRIOR TO THE START OF CONSTRUCTION. 5.THE CITY OF YELM SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE OF A TAP CONNECTION TO AN EXISTING MAIN. A CITY REPRESENTATIVE SHALL BE PRESENT AT THE TIME OF THE TAP. 6.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-800-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. 7.SIDE SEWER SERVICES SHALL BE PVC, ASTM D 3034 SDR 35 WITH FLEXIBLE GASKETED OR SOLVENT WELD JOINTS. 8.ALL PLASTIC PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE, INSTALLED 12" TO 18" UNDER THE PROPOSED SUBGRADE. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED "SEWER" WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. IN ADDITION, STEP SYSTEMS AND FORCE MAINS SHALL BE INSTALLED WITH 14 GAUGE, HEAVY COATED UF DIRECT BURY COPPER WIRE WRAPPED AROUND ALL PLASTIC PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. THE TAPE AND WIRE SHALL BE FURNISHED BY THE CONTRACTOR. 9.ALL BURIED POWER FOR STEP SYSTEMS SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12 ABOVE THE BURIED POWER. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE BACKING MARKED “POWER”. TAPE SHALL BE FURNISHED BY CONTRACTOR. 10.BEDDING OF THE SEWER MAIN AND ALL APPURTENANCES SHALL BE SAND AND COMPACTION OF THE BACKFILL MATERIAL SHALL BE REQUIRED IN ACCORDANCE WITH THE ABOVE MENTIONED SPECIFICATION (SEE GENERAL NOTE 5.60-A). 11.TEMPORARY STREET PATCHING SHALL BE ALLOWED FOR AS APPROVED BY THE CITY ENGINEER. TEMPORARY STREET PATCHING SHALL BE PROVIDED BY PLACEMENT AND COMPACTION OF 2 INCH MINIMUM ASPHALT CONCRETE COLD MIX. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE AS REQUIRED. 12.EROSION CONTROL MEASURES SHALL BE TAKEN BY THE CONTRACTOR DURING CONSTRUCTION TO PREVENT INFILTRATION OF EXISTING AND PROPOSED STORM DRAINAGE FACILITIES AND ROADWAYS. 13.PROVIDE TRAFFIC CONTROL PLAN(S) IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AS REQUIRED. 14.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A COPY OF THESE APPROVED PLANS ON CONSTRUCTION SITE AT ALL TIMES. 15.ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE CITY OF YELM. 16.ALL STEP MAINS SHALL BE HYDROSTATICALLY TESTED IN CONFORMANCE WITH THE ABOVE-REFERENCED SPECIFICATION FOR TESTING WATER MAINS. (SEE NOTE 1.) IN ADDITION, ALL STEP MAINS SHALL BE PIGGED/CLEANED IN THE PRESENCE OF THE CITY INSPECTOR PRIOR TO PLACING STEP MAIN IN SERVICE. 17.PRIOR TO BACKFILL ALL MAINS AND APPURTENANCES SHALL BE INSPECTED AND APPROVED BY THE CITY OF YELM. APPROVAL SHALL NOT RELIEVE THE CONTRACTOR FOR CORRECTION OF ANY DEFICIENCIES AND/OR FAILURES AS DETERMINED BY SUBSEQUENT TESTING AND INSPECTIONS. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO NOTIFY THE CITY OF YELM FOR THE REQUIRED INSPECTIONS. 18.PUMP CONTROL PANELS SHALL BE LOCATED ON GARAGE WALL OR REMOTE POST, 5- FEET FROM TOP OF PANEL TO FINISH GRADE, UNLESS OTHERWISE AUTHORIZED BY THE CITY OF YELM. 19.IN THE EVENT THAT THE DEPARTMENT OF LABOR AND INDUSTRIES OR THE CITY SHOULD REQUIRE A SEPARATE "ON-OFF" SWITCH CONTROLLING POWER TO THE PUMP CONTROL PANEL, SAID SWITCH SHALL HAVE A LOCKING COVER MODEL # 5031-0 RAYNTITE SINGLE GANG WEATHERPROOF COVER 1.406" DIAMETER. 20.INSPECTIONS FOR ONSITE STEP INSTALLATIONS ARE REQUIRED. A 48 HOUR NOTICE TO THE SEWER DEPARTMENT IS REQUIRED PRIOR TO THE INSPECTION. ITEMS NEEDING INSPECTION ARE: 20.1.TANK INSTALLATION, IE; BEDDING AND LOCATION 20.2.TANK INFILTRATION, EXFILTRATION TEST 20.3.S.S. PRESSURE TEST 20.4.SERVICE LINE PRESSURE TEST 20.5.FINAL INSPECTION 21.ALL POSTS USED TO SUPPORT PUMP CONTROL PANELS, MUST BE HOT DIP GALVANIZED UNISTRUT OR APPROVED EQUAL. GENERAL NOTES (SANITARY SEWER MAIN INSTALLATION) 10/09/2024 JACKSON ST SE 51 50 49 108 106 105 53 54 56 57 28 31 25 TRACT 'I' 58 TRACT 'E' TRACT 'G' 42 41 46 47 24 21 22 18 23 38 TRACT 'L' 104 107 109 43 48 55 45 TRACT 'H' 44 52 36 37 35 13 12 11 10 9 8 31 20 19 4400 S.F. 11 28 31 18 38 9 18 38 14 13 12 11 10 9 16 8 15 17 39 40 34 33 32 3029 27 26 N8 8 ° 4 1 ' 3 3 " W 13 2 3 . 4 8 ' S1° 14' 59"W1324.44' JACKSON ST. S E RO A D 2 LEVEL-SPREADER DISCHARGE DETENTION/WETPOND #1 EDGE OF WETLAND EXISTING WETLAND BUFFER EXISTING WETLAND BUFFER EDGE OF WETLAND EXISTING WETLAND BUFFER WETLAND "A" WETLAND "A" WETLAND "C" SPLIT RAIL FENCE (TYP.) SPLIT RAIL FENCE (TYP.) 40' MIN. BUFFER 40' MIN. BUFFER 1 C9.11 C9.1 40' MIN. BUFFER 52.23' SPLIT RAIL FENCE (TYP.) 1 C9.1 WETLAND LEGEND BUFFER REDUCTION BUFFER ADDITION 40' MIN. WETLAND BUFFER EXISTING WETLAND BUFFER SPLIT RAIL FENCE (PROPOSED WETLAND BUFFER) WETLAND BOUNDARY BUFFER AVERAGING TABLE WETLAND CATEGORY BUFFER CODE MINIMUM BUFFER EXISTING BUFFER AREA (SF) BUFFER REDUCTION (SF) BUFFER ADDITION (SF) DIFFERENCE (+/-) (SF) A IV 50'40'138,520 10,160 24,649 +14,489 C IV 50'40'14,439 143 500 +357 TOTAL 150,382 10,160 24,649 +14,489 N GRAPHIC SCALE 0 50 100 FEET 1" = 50 FEET 25 1 2 3 4 TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES 54 JMWGCHMCH 10/8/2024 PERMIT SET 2220471.10 P.O. BOX 73790 PUYALLUP, WA 98373-0790 COPPER RIDGE, LLC THE SUMMIT AT THOMPSON CREEK A PORTION OF THE SE 1/4 OF THE NE 1/4 OF SEC. 23 , AND A PORTION OF THE SW 1/4 OF THE NW 1/4 OF SEC. 24 TWN. 17 N., RGE. 1 E., W.M., CITY OF YELM, THURSTON COUNTY, WASHINGTON THE SUMMIT AT THOMPSON CREEK Know what's below. before you dig.Call R APPLICATION # 2024.00XX DATE: September 26, 2024 FILENAME: Q:\2022\2220471\10_CIV\CAD\_FINAL DESIGN\2220471-SH-WETL-BUFF-MITI.dwg C9.1 53 WETLAND BUFFER AVERAGING PLAN ALL FENCE POSTS SHALL BE INSTALLED PLUMB FRONT VIEW PLAN VIEW 2' - 6 " M I N 1' - 2 " 1' - 8 " 6' - 0 " 8" COMPACTED BACKFILL 12" FROM BOTTOM OF POST 18" MIN GIRTH MEASURED 18"NOTE: 10' SPLIT CEDAR RAIL 12" MIN. GIRTH PREDRILL AND NAIL THROUGH POST INTO EACH RAIL END WITH 16d CASING NAIL 1 NOT TO SCALE SPLIT RAIL FENCE 10/09/2024