Loading...
Tahoma Terra Storage FireTa h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g A Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III FA-1 1 10 FACP BPS1 BPS2 120vac 120vac 120vac12vdcBattery12vdcBattery12vdcBattery12vdcBattery 12vdcBattery 12vdcBattery F MM F F F F F F MM MM MM MM MM F MM MM Building A Building B Building C Building D Building H Building K Building L Building J QTY-5 QTY-5 QTY-5 QTY-5 QTY-5 QTY-5 QTY-5 QTY-5 QTY-3 QTY-1 QTY-1 QTY-1 QTY-1 QTY-1 QTY-1 QTY-1 QTY-1 QTY-1 QTY-1 FPLP 14/2c FPLP 14/2c FPLP 14/2c FPLP 16/2c 115cd115cd115cd115cd115cd115cd115cd115cd 15cd 15cd 30cd 75cd 30cd SBUS FPLP 16/4cSBUS FPLP 16/4c Panel Located in Building A Panel Located in Building D Panel Located in Building L One Line Riser Diagram FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 15.75" W FINISHED CEILING HERE FIGHTER PHONE PERMITTED HERE 6" H DEVICE INSTALLATION REQUIREMENTS SMOKE/HEAT DETECTOR 6" MIN FROM CEILING PERMITTED 3.9" D 15.75" W FACP 3' MIN 48" AFF 28" H FIRE MANUAL DETECTOR PULL SMOKE/HEAT PERMITTED HERE 3.9" D FIRE 4" 96" MAX SMOKE/HEAT DETECTOR 72" AFF FINISHED FLOOR CABINET HVAC SUPPLY FIRE ALARM 80" MIN FI N I S H E D W A L L 28.1" H 72" AFF AUDIO & VISUAL DEVICES 21.59" W FIRE 28" H 8.5" W 72" AFF SMOKE/HEAT DETECTOR PHONE STATION NOT DIFFUSER ANNNUCIATOR FIGHTER NOT PERMITTED HERE 66" AFF 5.05" D PULL HANDSET JACK 1.5" D 3' MIN 4" 12" MAX Device Type Qty Total Qty Total 6808 Control Panel 1 x 0.190000 =0.190000 1 x 0.250000 =0.250000 SK-PHOTO 3 x 0.000300 =0.000900 3 x 0.000300 =0.000900 x 0.000200 =x 0.000450 = 1. Control Panel 2. Addressable SLC Devices IntelliKnight 6808 Battery Calculation Secondary Power Source Requirements Standby Current (amps)Secondary Alarm Current (amps) Current Draw Current Draw x 0.000375 =x 0.000375 = SK-MONITOR 40 x 0.000375 =0.015000 40 x 0.000375 =0.015000 x 0.000375 =x 0.000375 = SK-PULL-SA 10 x 0.000375 =0.003750 10 x 0.000375 =0.003750 x 0.000375 =x 0.000375 = x 0.000000 =x 0.000000 = NAC 1 0.000000 =0.165000 =0.165000 NAC 2 0.000000 =0.105000 =0.105000 NAC 3 0.000000 =0.218000 =0.218000 NAC 4 0.000000 =0.218000 =0.218000 0.209650 0.975650 8. Notification Appliance Circuits Total Standby Load Total Alarm Load Note 2: Use the dropdowns in the yellow cells to enter values. x =5.032 AH x =0.082 AH 5.114 AH =x 1.20 6.14 AH Total Current Load Multiply by the Derating Factor 1.2 Total Ampere Hours Required Recommended Batteries: BAT-1270 - 7AH Batteries Required Alarm Time in Minutes 5 Minutes Alarm Load Current (Amps)0.97565 Amps 0.084 Calculation in Total Sheet Required Standby Time in Hours 24 Hours Standby Load Current 0.20965 Amps 24 IntelliKnight 6808 Battery Calculation Note 1: You are fully responsible for verifying these calculations. Starting Voltage Minimum Voltage @ EOL Voltage Drop Warning % Wire Type Actual Resistance Percent Drop Circuit Name AWG Ohms Percent NAC 1 #14 Solid 1.23 0.99% NAC 2 #14 Solid 1.54 0.79% NAC 3 #14 Solid 0.61 0.66% NAC 4 #14 Solid 3.07 3.28% 0.218 3.07 100 20.27 0.218 3.07 500 19.73 0.165 3.07 200 20.20 0.105 3.07 250 20.24 Current Draw Resistance Length Voltage @ EOL Amps Ohms/1000 ft. Feet (One Way)Volts IntelliKnight 6808 EOL Voltage Drop 20.4 Volts 16 Volts 10.00% 24 5 1.2 Date: 10 Panel ID: Model:3.0 Amps Location: Volts:24 VDC 6.0 Amps Wire AWG Ohms Per Length(ft)Actual Volts @ Standby Alarm & Type 1000 Ft.One-Way Ohms EOL 5496 1 0.040 0.160 NAC #1 ###0.000 0.218 #14 Solid 2.52 150 0.76 20.24 0.81% NAC #2 ###0.000 0.218 #14 Solid 2.52 450 2.27 19.91 2.42% NAC #3 ###0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% NAC #4 ###0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% 0.040 0.596 24 0.083 (5 Mins) 0.960 0.050 %DropCurrent Draw 5496 Pwr Module Part.#Description Qty 1.20Multiply By The Derating Factor Circuit 4 Standby Time In Hours Circuit 2 Circuit 1 Circuit 3 Voltage Drop Warning Threshold % : Standby Hours: Alarm Mins: Derating Factor: Project Name:Tahoma Terra Storage Project ID: Prepared By:Brian Rudebeck Command Shortcuts Total Standby AH Required 5496 Power Expander Calculations Max NAC Current: Max Panel Current: Building D Riser Room Version 02.24.09 BPS 1 5496 Power Expander Total Alarm Current (Amps)Total Standby Current (Amps) Alarm Time In Minutes / 60 Minimum Battery AmpHours Required 1.21 1.01Total Combined AH Required Total Alarm AH Required Global Project Values: Configure Circuits Print Page 24 5 1.2 Date: 10 Panel ID: Model:3.0 Amps Location: Volts:24 VDC 6.0 Amps Wire AWG Ohms Per Length(ft)Actual Volts @ Standby Alarm & Type 1000 Ft.One-Way Ohms EOL 5496 1 0.040 0.160 NAC #1 ###0.000 0.218 #14 Solid 2.52 150 0.76 20.24 0.81% NAC #2 ###0.000 0.218 #14 Solid 2.52 450 2.27 19.91 2.42% NAC #3 ###0.000 0.218 #14 Solid 2.52 650 3.28 19.69 3.50% NAC #4 ###0.000 0.218 #14 Solid 2.52 700 3.53 19.63 3.77% 0.040 1.032 24 0.083 (5 Mins) 0.960 0.086 %DropCurrent Draw 5496 Pwr Module Part.#Description Qty 1.20Multiply By The Derating Factor Circuit 4 Standby Time In Hours Circuit 2 Circuit 1 Circuit 3 Voltage Drop Warning Threshold % : Standby Hours: Alarm Mins: Derating Factor: Project Name:Tahoma Terra Storage Project ID: Prepared By:Brian Rudebeck Command Shortcuts Total Standby AH Required 5496 Power Expander Calculations Max NAC Current: Max Panel Current: Building L Riser Room Version 02.24.09 BPS 2 5496 Power Expander Total Alarm Current (Amps)Total Standby Current (Amps) Alarm Time In Minutes / 60 Minimum Battery AmpHours Required 1.26 1.05Total Combined AH Required Total Alarm AH Required Global Project Values: Configure Circuits Print Page FACP Battery and Voltage Drop Calcs BPS1 Battery and Voltage Drop Calcs BPS2 Battery and Voltage Drop Calcs .165 .105 .218 .218 .218 .218 .218 .218 .218 .218 C N 8 8 ° 1 5 ' 1 5 " W 49 1 . 0 1 ' N 10°26' 4 7 " E 93.40' 458 . 8 2 ' S 38 ° 4 6 ' 1 9 " E 147 . 3 9 ' N 42 ° 1 0 ' 5 4 " W 33.77' 254.80' 254.80' S 01°42'11" W S 5 2 ° 5 2 ' 1 4 " E 98. 0 1 ' S 01°16'01" W 33.44' 99. 2 2 ' RI V E R RO C K PI L E BE R R Y V A L L E Y R D S E TAHOMA BLVD SE ME T A L PI P E C Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g A Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III FA-2 2 10 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g A Golf c a r H F A C P F Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III F 75cd 15cdEOLC-2 FACPC-2 30cdEOLC-1 75cd 15cd30cd FACPC-1 FACPC-3 115cdEOLC-3 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM 3 FA-3 FACP F BPS1 MM BPS2 WP WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) F 10 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g B Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III 4 FA-4 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM 115cdEOLC-3 FACPCircuit 4 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) F 10 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g C Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III 5 FA-5 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM F 115cdEOLC-3 BPS 1Circuit 2 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 10 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g D Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III 6 FA-6 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM F 115cdEOLC-3 BPS 1Circuit 1 BPS1 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 10 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g H Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III FA-8 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM F 115cdEOLC-3 BPS2Circuit 3 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 107 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g J Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III FA-9 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM F 115cdEOLC-3 BPS2Circuit 4 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 108 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g K Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III FA-10 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM F 115cdEOLC-3 BPS2Circuit 2 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 109 Ta h o m a T e r r a S t o r a g e Ta h o m a B o u l e v a r d Ye l m , W a s h i n g t o n Bu i l d i n g L Brian Rudebeck NICET Certification No. 147647 Fire Alarm Systems - Level III FA-11 WF MM MM MM Water Flow Riser Tamper Riser Tamper Backflow Tamper Backflow TamperMM F 115cdEOLC-3 BPS2 BPS2Circuit 1 WP FACP F BPS1 MM BPS2 WP Fire Alarm Control Panel Booster Power Supply 1 Booster Power Supply 2 Smoke Detector Manual Pull Station Input Module Strobe Horn/Strobe Outdoor Horn/Strobe Device Legend (Purpose marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) (Candela setting marked on drawing) 1010