Loading...
2021.0028-2021.0028 7677 - Tahoma Blvd Apts - Bldg 1 - Sprinkler Plan-approvedBATT TYPE INSULATION TENTED OVER ALL ATTIC SPRINKLER PIPE (BY OTHERS)9'-0"9'-0"FLOOR LINE R-10 RIGID INSUL TOP OF SLAB 12 SAND AND GRAVEL BASE. 2 X 4 STUDS AT 16" O.C. WITH 5/8" GYP. BD. MANUF. TRUSSES MANUF. TRUSSES (WARM SIDE) GABLE END VENT 2X6 OVERFRAME 4 TOP PLATE FLOOR LINE RUN 24" MIN BELOW 4" CONC. SLAB W/ 6 MIL. VAPOR RUN 24" MIN BELOW INTERIOR WALLS- GABLE-END PER TRUSS MANUF 24" O.C. MAX VAPOR BARRIER @ 24" O.C. 12 TOP PLATE SEE STRUCTURAL TOP OF SLAB 4 BARRIER OVER 4" COMPACT R-10 RIGID INSUL UNLESS OTHERWISE NOTED. 24" O.C. MAX 2 X 6 STUDS AT 16" O.C. @ RESTROOMS SEE EXT ELEVATIONS GIRDER TRUSS R-49 INSULATION W/ CONT. UNIT B KITCHEN LIVING LIVING KITCHEN LIVINGKITCHEN UNIT BUNIT B KITCHEN LIVING UNIT B 32280.4' 2-BED UNIT UNIT 2B 2-BED UNIT UNIT 2D 2-BED UNIT UNIT 2A 2-BED UNIT UNIT 2C 32280.4' UP UP W D D W D D W W 1¼ -DN1¼ -DN1¼ -DN1¼ -DN1002 1001 1004 1003 1 1 1 11 1 1111 1 1 1 11 11 11 111 1 111 1 1 1 111111 11 111 11 111 111 1 1111 1 11 11 11 111 1 11 111 11 1 11 11111 1 11 1 11 1 1 111 111 1 1 1111 111122 120 101 102 121 103 8'-0" CLG BEDROOM KITCHEN 9'-0" CLG WIC 9'-0" CLG MSTR <55FT² LIVING ROOM BEDROOM 3 LIVING ROOM BEDROOM BEDROOM 9'-0" CLG 9'-0" CLG MSTR 8'-0" CLG LIVING ROOM 9'-0" CLG BEDROOM 3 <55FT² UTILITY BATH LIVING ROOM WIC BATH UTILITY MSTR WICBEDROOM 3 MSTR 9'-0" CLG 9'-0" CLG BATHBATH WIC 9'-0" CLG UTILITY BATH <55FT² UTILITY KITCHEN 9'-0" CLG BATHBATH 9'-0" CLG BEDROOM 3 8'-0" CLG 9'-0" CLG 9'-0" CLG <55FT² BEDROOM 8'-0" CLG KITCHENKITCHEN BATH CONC.PATIO CONC.PATIO CONC. PATIO PATIO CONC. 2 (UNDERGROUND) 1FP1 2-BED UNIT UNIT D *1B TYPE 'B' UNIT 2-BED UNIT UNIT D *1D TYPE 'B' UNIT 2-BED UNIT UNIT D *1A TYPE 'B' UNIT 2-BED UNIT UNIT D *1C TYPE 'B' UNIT 32280.4' UP UP D W W W W D D D 2 -DN112 2 -DN1112 -UP1 1 1 1 11¼11111 1 1 11 1 1 11 11¼ 1 11¼ 1 111 11 1111¼1¼1¼111 1 1¼1¼1¼1¼1 1 1 11¼11 1 11 1 11 11 11 11¼ 1 1¼1¼1¼11 11 11 1 1¼1111111111¼1¼11¼111111111¼1¼1½1½1½1½1½1½1½ 1½1¼107 106 124 123 108 105 109 104 110 1¼ -UP1¼ -UP1¼ -UP1¼ -UPMSTRBEDROOM 9'-0" CLG 8'-0" CLGBEDROOM 39'-0" CLG WIC BATH<55FT²BATH LIVING ROOM 9'-0" CLG KITCHENUTILITY 9'-0" CLG <55FT² BEDROOM 3 BEDROOM UTILITY LIVING ROOM BATH WIC MSTR KITCHEN BATH 8'-0" CLG 9'-0" CLG BEDROOM 9'-0" CLG 9'-0" CLG BEDROOM 3 BEDROOM MSTR LIVING ROOM BEDROOM 3 UTILITY LIVING ROOM BATH WIC MSTR 9'-0" CLG BATH WIC UTILITY <55FT² KITCHEN BATH 9'-0" CLG8'-0" CLG 9'-0" CLG 8'-0" CLG KITCHEN BATH CONC.PATIO CONC.PATIO PATIOCONC. CONC.PATIO <55FT² 9'-0" CLG9'-0" CLG GRAVEL91' PVC211' PVC6"6"61' PVC2"TAHOMA BOULEVARD SE105' DI 52 30' DI 52 33' PVC 1 0 5 ' D I 5 2 27' DI 526' DI 5256' PVC10' PVC 178' PVC52' PVC224' PVC 127' PVC32' PVC2"7' PVC 2" 10' PVC 6"6" 8 "6"6" 6"6"6" 2"2"2"30' PVC9' PVC 2"2"2" 6" 4 - 1" MALE ADAPTER 2" DERINGER 30 (DCDA) WIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS (INSTALLATION AND 6 ALL CONTROL VALVE HANDLES TO BE REMOVED2 RISER LEGEND 2"2"1" VALVE FOR DRAIN5 - GRADE 1 - 2" FEMALE ADAPTER 2 - 7 1 - 3 2"2"2" CHECK VALVE 2" MALE ADAPTER 2" 1½"11" DRAIN LINE PIPED TO EXTERIOR OF BUILDING FSI START 6 - 2 - 2" SUPPLY LINE TO BE PROVIDED BY OTHERS WIRING BY OTHERS) 8 RISER NOTES 6" 120VAC ALARM BELL 4 7 -2"1½"2"3'-0"WATER PRESSURE GAUGE 8 -9 - 3 - GRADE 3 - WATER FLOW SWITCH.2" WATER SUPPLY LINE AND PLACED IN HEAD BOX AT TIME OF FINAL TO BE CONNECTED TO 5 UPRIGHT SPRINKLER TO PROTECT RISER 1 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING 9 WATER FLOW ALARM SWITCH WIRED TO ALARM BELL 2" CHECK VALVE 2" 10 -TO REMOTE FDC (BY OTHERS) 10 FSI START2" MALE ADAPTER 2"SCOPE OF WORK: INSTALL NEW NFPA 13R FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE PER NFPA 13R (2019) GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2019). 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. RISER ASSEMBLY LOCATED IN ATTACHED RISER ROOM (FSI START POINT). 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13R MULTI FAMILY RESIDENCE. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF YELM. 4. MATERIALS PER NFPA #13R STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13R AND CITY OF YELM. 6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE FIELD NOTES: 1. ALL NEW PIPE IS TO BE CPVC. 2. ALL NEW FITTINGS ARE TO BE CPVC. 3. DESIGN CRITERIA TO BE BASED ON NFPA 13R: A. SPRINKLER SPACING NOT TO EXCEED (16' X 16') OR (8') OFF OF WALLS MAXIMUM. B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 16' X 16' = 13 GPM @ 7 PSI. TOLCO FIG. #28M NTS HANGER TYPE CP ATTIC INSULATION (BY OTHERS). BOTTOM CHORD OF TRUSS USE BATT TYPE INSULATION GWB CEILING (BY OTHERS). USE BATT TYPE TENT FIRE SPRINKER PIPEBEFORE INSULATING ATTIC WET PIPE FREEZE CPVC FIRE SPRINKLER PIPE FOR TENTING INSULATION FOR TENTING. NTS PROTECTION DETAIL TOLCO FIG. #24 NTS HANGER TYPE CP NTS HANGER TYPE CP TOLCO FIG. #29 FP1 1 ½"8QR½"155QRWHC. PENDBRC. PEND200804.9BR4.9WHN/A1551QR½"BR5.61"QR155CH8CH5.61"RA1664DRY ECSWQR155RELIABLECH6CHDRY HSWVK494VIKINGVIKINGVK494VIKNGVK178UPRIGHTVIKINGVK4674.9REVISIONS: REV# DATE: SCALE: DATE BY HANGER LEGEND: DESCRIPTION AHJ: CONTRACT WITH: SHEET NUMBER: REVIEWED BY: DRAWN BY: JOB NUMBER: DRAWING SYMBOLS:QTY103SPRINKLER LEGENDSYMMFRSINRESPTYPEKTEMPTHRDFINISHESCTOTAL THIS PROJECT =T D TOP BEAM CLAMP W/ STRAP H X - S SAMMY SUPER SCREW (GST20/30) TRAPEZE CP CPVC HANGER HILTI KWIK HUS-EZ SD SAMMY SIDEWINDER (SWDR 516) (SEE CHART) - ELEVATION - CENTERLINE A.1 - HYDRAULIC NODE - WELDED - FLEXIBLE GROOVED FFAFF CC DATUMDATUM 1 COUPLING - BRANCHLINE - ELEVATION10'-10"- SEISMIC BRACE LL TSTS DECK PIPE TAG DECK & LENGTH CUT #1 NUMBER - CENTERLINE 9'-0- PIPE HANGER - PIPE SIZE - RIGID GROOVED CAC LL0'-10"0'-10"OF PIPE TOOF PIPE TO COUPLING AS NOTED CCS 05/17/22 7677 CITY OF YELM JNZ FP1 OF 1 YELM, WA 9859715035 BERRY VALLEY ROAD SETAHOMA BLVD APARTMENTSPUYALLUP, WA 98371 SCHUUR BROS INC GC: JERRY SCHUUR - 253-651-3786 PO BOX 597 1524 45TH STREET EAST, SUITE 102 SUMNER, WA 98390 (253) 826-0099WWW.FIRESPRINKLERSINC.COM BUILDING SECTION A SCALE: NTS SCALE: 1/8" = 1'-0"NORTHVICINITY MAP NORTHSCALE: 1/8" = 1'-0" MAIN FLOOR - SPRINKLER PIPING PLAN NORTHSCALE: NTS UPPER FLOOR - SPRINKLER PIPING PLAN SCALE: NTSNORTH BUILDING 1 SITE PLAN SCALE: NTS RISER DETAIL HYDRAULICALLY DESIGNED GPM FLOWING: 54 1130 56 HYDRAULICALLY DESIGNED DATE & TIME: THIS SYSTEM IS NOT RESIDUAL: - THIS SYSTEM IS STATIC: - FLOW TEST - HYDRAULIC DESIGN INFO "OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE FOR CPVC AND IPS PIPE HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER "DOUBLE OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE WA CL# FIRESI*988RJ X GATE VALVE (BY OTHERS) 2½" X 2½" SINGLE OUTLET OPEN SNOOT FDC (BY OTHERS) +/- 175' OF 2" PVC SUPPLY (BY OTHERS) DCDA LOCATED INSIDE RISER ROOM FIRE SPRINKLER RISER ROOM W/ KNOX BOX (BY OTHERS) FIRE HYDRANT EXISTING 8" WATER MAIN (EFFECTIVE POINT OF FLOW TEST) 6" PVC SITE SUPPLY (BY OTHERS) FIRE HYDRANT (BY OTHERS) YARD POST INDICATING VALVE (BY OTHERS) BLDG 3BLDG 2 THIS PERMIT BLDG 4 BLDG 1 115 116 117 118 1 111 110 112 113 114 112 SITE 16' X 16' RESIDUAL: HYDRAULIC DESIGN INFO 52.60 GPM @ 44.507 PSI THIS AREA HAS BEEN HYDRAULICALLY CALCULATEDTO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D) OF: REMOTE AREA #1 MAX AREA/HEAD: SYSTEM DEMAND: DENSITY: K-FACTOR: HYDRAULICALLY DESIGNED THIS SYSTEM IS 54 HYDRAULICALLY DESIGNED AREA 1 56 .05 GPM / SQ FT -DATE & TIME: 4.9K 13 GPM @ 7.0 PSI USING 16' X 16' HEAD SPACING GPM FLOWING: - SYSTEM DESIGN - - FLOW TEST - REMOTE AREA: THIS SYSTEM IS NOT STATIC: 1130 Christopher Cameron Smith 0087-0618-C Level 3 Fire Sprinklers Incorporated FIRESI*988RJ 05/23/2022Detail provided by applicant. NFPA 13R-Section 6.8.9 requires piping shall be provided downstream of all back flow prevention valves for forward flow tests at at a minimum flow rate of the system demand. TOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 06/23/2022 4 No Comments Comments Noted on drawings