Loading...
2021.0028-2021.0028 YELM APTS - BLDG 1 FIRE - 07-26-2022-approvedA 16 FPLR 2 SLC ADDRESSABLE CIRCUIT B 14 FPLR 2 NOTIFICATION CIRCUIT C 16 CI-FPLR SHIELDED 2 FIREFIGHTER PHONE VOICE CIRCUIT D 16 CI-FPLR SHIELDED 2 FIREFIGHTER PHONE SLC CIRCUIT E 16 FPLR 4 ANNUCIATOR CIRCUIT W/ 24VDC POWER F 18 CMR 2 2-WAY COMMUNICATION SYSTEM POWER G 18 TWISTED SHIELDED 2-PAIR CMR 2 2-WAY COMMUNICATION SYSTEM VOICE H 24 CAT 5 CMP 8 TELCO SERVICE CONNECTION I 16 TWISTED SHIELDED 2 VOICE EVACUATION SPEAKER CIRCUIT J 14 FPLP 2 24VDC AUX POWER CIRCUIT TAHOMA APARTMENTS BUILDING 1 15035 BERRY VALLEY RD. SE YELM, WA 98597 HVAC CONTRACTOR SHALL PROVIDE, INSTALL AND PROVIDE POWER TO ANY REQUIRED DUCT DETECTORS. HVAC CONTRACTOR SHALL ALSO MAKE ALL CONNECTIONS AND TERMINATIONS TO HVAC SYSTEMS TO FACILITATE FAN SHUT DOWN FROM DUCT DETECTORS AND HVAC CONTRACTOR SHALL ALSO MAKE AVAILABLE A COMMON TERMINATION POINT FOR CONNECTION TO THE FIRE ALARM SYSTEM TO FACILITATE FAN SHUT DOWN UPON RECEIPT OF A GENERAL FIRE ALARM IF SUCH A FUNCTION IS REQUIRED PER APPLICABLE BUILDING CODES. ELEVATOR CONTRACTOR SHALL MAKE ALL NECESSARY CONTROL CONNECTIONS INSIDE ELEVATOR CONTROL EQUIPMENT AND PROVIDE A REPRESENTATIVE IN A TIMELY MANNER TO FACILATE AN ELEVATOR SYSTEMS PRETEST PRIOR TO REQUESTING AN ELEVATOR SYSTEMS FINAL INSPECTION, ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED 120V 20 AMP DEDICATED CIRCUITS AS NECESSARY TO POWER ALL FIRE ALARM CONTROL EQUIPMENT AND LABEL ELECTRICAL SERVICE PANEL CLEARLY IN RED TO INDICATE FIRE ALARM POWER CIRCUITS. ALL FIRE ALARM POWER CIRCUIT BREAKERS WILL HAVE LOCK OUT DEVICES INSTALLED BY ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE AND TERMINATE ALL REQUIRED CONNECTIONS TO SMOKE DAMPERS IF PRESENT AND PROVIDE AND TERMINATE THE LINE VOLTAGE POWER CONNECTIONS TO A 24VDC COIL RELAY LOCATED AT THE FIRE ALARM CONTROL PANEL TO FACILITATE CONNECTION TO SAID RELAY FOR THE PURPOSE OF ACTIVATING SMOKE DAMPER UPON RECEIPT OF GENERAL FIRE ALARM ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT NECESSARY TO FACILITATE ACCESS TO OTHERWISE UNREACHABLE PORTIONS OF THE STRUCTURE AND/ OR LOCATIONS DETACHED FROM THE STRUCTURE THAT REQUIRE CONNECTION TO FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO SPRINKLER SYSTEM POST INDICATOR, VALVES REMOTE WATER SUPPLY PITS THAT WILL CONTAIN TAMPER SWITCHES, ETC. 6)ELECTRICAL CONTRACTOR SHALL PROVIDE ALL BOXES AND HARDWARE NECESSARY TO FACILITATE ABOVE LISTED ELECTRICAL SCOPE OF SYSTEMS INTEGRATION. GENERAL CONTRACTOR SHALL COORDINATE AND BE MADE RESPONSIBLE FOR THE COMPLETION OF ALL TRADES INVOLVED IN THE FIRE ALARM SYSTEM INSTALLATION PROCESS. GENERAL CONTRACTOR SHALL ADHERE TO THE REQUIREMENTS OF THE BELOW LISTED FIRE ALARM SYSTEMS COMPLETION CHECK LIST AND THIS SECTION AND WILL ENSURE ALL ASPECTS OF WORK HAVE BEEN COMPLETED PRIOR TO REQUESTING A FINAL FIRE ALARM SYSTEMS INSPECTION. THESE DRAWINGS RELATE TO FIRE ALARM INSTALLATION ONLY AND IN NO WAY SHOULD BE CONSTRUED AS GENERAL CONSTRUCTION DOCUMENTS OR AN ADDENDUM TO ANY OTHER CONSTRUCTION DRAWINGS. ALL CIRCUITS TO BE CLASS B SUPERVISION, FIRE ALARM SYSTEM TO REPORT BY DEVICE ADDRESSABLE POINT IN MULTIPLEX SYSTEM OR BY ZONE IN CONVENTIONAL SYSTEMS AS NOTED IN SUBMITTAL DOCUMENTS AND THIS PAGE ALL WIRING TO BE FIRE POWER LIMITED AND PROPERLY RATED FOR INSTALLATION ENVIRONMENT SMOKE DETECTORS SHALL NOT BE INSTALLED CLOSER THAN 36" TO ANY HVAC INLET/OUTLET AREA SMOKE DETECTORS SHALL NOT BE INSTALLED MORE THAN 30' APART CENTER TO CENTER AND NO MORE THAN 15' FROM ANY WALL OR PROTECTED AREA CORRIDOR SMOKE DETECTORS SHALL NOT BE INSTALLED MORE THAN 42' APART CENTER TO CENTER AND NO MORE THAN 15' FROM ANY WALL OR PROTECTED AREA ALL WALL MOUNTED NOTIFICATION AND INITIATING DEVICES SHALL BE MOUNTED PER MOUNTING DETAIL ON THIS PAGE FACP TO BE OPERATED AT A TEMPERATURE NO LOWER THAN 32 DEGREES GENERAL NOTES INSTALLATION NOTES PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA000 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542COVER PAGE SHEET INDEX SHEET NUMBER SHEET TYPE FA000 COVER PAGE FA001 DETAILS FA002 BATTERY CALCS FA003 BATTERY CALCS FA004 BATTERY CALCS FA005 RISER FA100 FLOOR PLAN WIRE LEGEND WIRE CALLOUT SIZE-IN./AWG TYPE #CONDUCTORS FUNCTION P AMM 2 1 SMOKE DETECTOR ADDRESSABLE GAMEWELL ASD-PL2F 3-0 NL ON 4 SQ DP N/A-3.0 RING PULL STATION GAMEWELL MS-7AF SG NL ON-4 SQ DP N/A-SG RING WATERFLOW SWITCH VALVE TAMPER SWITCH AND PIV VALVE DUAL INPUT MONITOR MODULE WEATHERPROOF WALL MOUNT HORN STROBE EXTERIOR BELL AND STROBE FIRE ALARM CONTROL PANELFACP N/A N/A BY OTHERS BY OTHERS N/A N/A BY OTHERS BY OTHERS GAMEWELL AMM-2IF 2G NL ON-4 SQ DP N/A-2G RING SYSTEM SENSOR P2WL SG NL ON-4 SQ DP N/A-SG RING SYSTEM SENSOR DG WP MANUFACTURER SUPPLIED BOXSSM24-10 GAMEWELL SURFACE RECESSED N/AGWF-7075 1 1 3 2 1 1 1 QTY SYMBOL DESCRIPTION MANUFACTURER MODEL #MOUNT DEVICE MOUNT ACC. SYMBOL LEGEND WP L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:19 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA001 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542SHEET_NAME BLDG 1 THIS PERMIT BLDG 3 BLDG 4 TAHOMA BOULEVARD SEGRAVELBLDG 2 NOT TO SCALE SITE PLAN PIV LOCATION 3/4" PVC TO SPRINKLER RISER ROOM L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:21 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA002 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542SHEET_NAME CABINETINNER DOOR REDGREENGRAYBROWNREDGREENGRAYBROWNNO C NC RELAY 2 NO C NC RELAY 1 NO C NC TROUBLE -+-+ SLC IN SLC OUT -+-+A B SBUS -+ NAC 1 -+ NAC 2SLC PROG MODEL #7860 MODEL #7860 CONNECTION OF TELEPHONE LINES L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:21 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA003 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542SHEET_NAME TYPICAL NAC DEVICE CONNECTION FROM FACPTYPICAL NAC DEVICE CONNECTION FROM BPS 1A-1 1A-2 EOL 2A-22A-1 120VAC DEDICATED CIRCUIT NEUTRAL GROUND HOT TO PM-9 TB2-2 TO PM-9 TB2-1 PSN-106 POTTER BOOSTER PANEL SUPPLY EOL EOL ASD-PL2F SMOKE DETECTOR ATD-2LF HEAT DETECTOR T6 T7 T2 T1 RELAY COMMON 2 NORMALLY CLOSED 2 NORMALLY OPEN 2 RELAY COMMON 1 NORMALLY CLOSED 1 AOM-2RF NORMALLY OPEN 1 IF ANY WIRING TO TERMINALS 3-9 IS NOT POWER LIMITED, THE CB500 BARRIER IS REQUIRED. THE CB500 INCLUDES A NON POWER LIMITED LABEL, WHICH MUST BE PLACED OVER THE POWER LIMITED TERMINAL INFO. ON THE NAME PLATE. 9 8 7 6 5 0 1 2 3 4 AMM 4F TYPICAL SLC DEVICE CONNECTIONS 1 2 3 4 MS-7 PULL STATION TYPICAL SPRINKLER DEVICE CONNECTION 3 2 1 3 2 1 47K EOL DNR DUCT DETECTOR TEST COIL + TEST COIL - COMM + OUT (CONV ONLY) + COMM - RA/RTS - RA + RTS + TEST COIL + TEST COIL - COMM + OUT (CONV ONLY) + COMM - RA/RTS - RA + RTS + RTS151KEY REMOTE TEST STATION 1 2 3 4 5 JUMPER - SLC OUT AMM-21F DUAL MONITOR MODULE 9 8 7 6 5 0 1 2 3 4 47K EOL 47K EOL H L TO NEXT SLC DEVICE TYPICAL SPRINKLER DEVICE CONNECTIONS 0 151413 12 11 10 9 8765 4 3 2 1 0 9 8765 4 3 2 1 TO SLC LOOP (-)(+) (+)(-) AMM-2F +-+- 47K EOL + SLC OUT TO GWF - 7075 TYPICAL NAC DEVICE CONNECTION FROM FACPTYPICAL NAC DEVICE CONNECTION FROM BPS 1A-1 1A-2 EOL 2A-22A-1 120VAC DEDICATED CIRCUIT NEUTRAL GROUND HOT TO PM-9 TB2-2 TO PM-9 TB2-1 PSN-106 POTTER BOOSTER PANEL SUPPLY EOL EOL ASD-PL2F SMOKE DETECTOR ATD-2LF HEAT DETECTOR T6 T7 T2 T1 RELAY COMMON 2 NORMALLY CLOSED 2 NORMALLY OPEN 2 RELAY COMMON 1 NORMALLY CLOSED 1 AOM-2RF NORMALLY OPEN 1 IF ANY WIRING TO TERMINALS 3-9 IS NOT POWER LIMITED, THE CB500 BARRIER IS REQUIRED. THE CB500 INCLUDES A NON POWER LIMITED LABEL, WHICH MUST BE PLACED OVER THE POWER LIMITED TERMINAL INFO. ON THE NAME PLATE. 9 8 7 6 5 0 1 2 3 4 AMM 4F TYPICAL SLC DEVICE CONNECTIONS 1 2 3 4 MS-7 PULL STATION TYPICAL SPRINKLER DEVICE CONNECTION 3 2 1 3 2 1 47K EOL DNR DUCT DETECTOR TEST COIL + TEST COIL - COMM + OUT (CONV ONLY) + COMM - RA/RTS - RA + RTS + TEST COIL + TEST COIL - COMM + OUT (CONV ONLY) + COMM - RA/RTS - RA + RTS + RTS151KEY REMOTE TEST STATION 1 2 3 4 5 JUMPER - SLC OUT AMM-21F DUAL MONITOR MODULE 9 8 7 6 5 0 1 2 3 4 47K EOL 47K EOL H L TO NEXT SLC DEVICE TYPICAL SPRINKLER DEVICE CONNECTIONS 0 151413 12 11 10 9 8765 4 3 2 1 0 9 8765 4 3 2 1 TO SLC LOOP (-)(+) (+)(-) AMM-2F +-+- 47K EOL + SLC OUT TO GWF - 7075 L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:22 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA004 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542SHEET_NAME L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:22 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings FACP B 1-1 110CD WP EOL 5.1K P AMM 2 A A 4.7K EOL 4.7K EOL 4.7K EOL WATERFLOWBACKFLOW INBACKFLOW OUTA B 4.7K EOL AMM 2 4.7K EOL 4.7K EOL A TO TELCO (2) LINES BY OTHERS TO 120 VAC DEDICATED CIRCUIT BY OTHERS LEVEL 2 LEVEL 1 POST INDICATOR VALVE (PIV)PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA005 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542SHEET_NAME FIRE ALARM DEVICE MOUNTING HEIGHT DETAIL MINI HORN APPLIANCE 90" AF.F.. AND AT LEAST 6" DOWN FROM CEILING HORN/STROBE - STROBE APPLIANCE 80" A.F.F. LOW FREQUENCY - STROBE APPLIANCE IN SLEEPING AREA 28" DOWN FROM CEILING AND WITHIN 16' OF PILLOW-MUST BE 110 CD MANUAL PULL STATION 48" A.F.F. TOP OF BOX P M LF L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:24 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings 4.7K EOL 1-1 110CD 4.7K EOL WP FACP P B AMM 2 AMM 2 PIV 3/4" PVC W/ (2) 18 AWG STRANDED TYPE THWN B 4.7K EOL PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA100 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542BLDG 1 MAIN FLOOR 1/8" = 1'-0" BLDG 1 MAIN FLOOR 2" GRADE 2"2" GRADE 1½"1½"2"2"2"12"2"2"6" 120VAC ALARM BELL TO BE CONNECTED TO WATER FLOW SWITCH. (INSTALLATION AND WIRING BY OTHERS) 2" CHECK VALVE 2" MALE ADAPTOR FSI START 2" MALE ADAPTOR FSI START 1" MALE ADAPTOR 2" FEMALE ADAPTOR RISER NOTES 1 - ALL CONTROL VALVE HANDLE TO BE REMOVED AND PLACED IN HEAD BOX AT TIME OF FINAL 2 - WIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS 3 - 2" SUPPLY LINE TO BE PROVIDED BY OTHERS RISER LEGEND 1 - 2" WATER SUPPLY LINE 2 - 2" DERINGER 30 (DCDA) 3 - WATER FLOW ALARM SWITCH WIRED TO ALARM BELL 4 - WATER PRESSURE GAUGE 5 - 1" VALVE FOR DRAIN 6 - 1" DRAIN LINE PIPED TO EXTERIOR OF BUILDING 7 - UPRIGHT SPRINKLER TO PROTECT RISER 8 - 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING 9 - 2" CHECK VALVE 10 - TO REMOTE FDC (BY OTHERS) N.T.S. SPRINKLER RISER DETAIL AMM 2 47K EOL 47K EOL 47K EOL A WATER FLOW SWITCH BACK FLOW IN BACK FLOW OUT GAMEWELL 7075 FACP 15.12" x 12.71" A A A A P MAIN PULL TO 120 VAC DEDICATED CIRCUIT TO TELCO (2) LINES BY OTHERS 6' A.F.F. N.T.S. FIRE ALARM RISER DETAIL B 47K EOL AMM 2 47K EOL A POST INDICATOR VALVE (PIV) A L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:24 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings PROJECT NAMEPROJECT TYPEPROJECT LOCATIONPROJECT NUMBER SHEET NAME DRAWN DATE DRAWING NUMBER CITY APPROVAL STAMP DESIGNER OF RECORD FA101 CW LC220007 07-20-2022PLAN SET NOTESTAHOMA APARTMENTS BLDG 1FIRE ALARM15035 BERRY VALLEY ROAD SEYELM, WA 985971234567NICET Certifcation Number: 148653 Engineering Technician, Level III Paul J. Powloski Authorizing Signature: ______________________ Fire Alarm Systems PUYALSOKNELUPPA11409 58Th Ave E-Puyallup, WA. PH 253-848-6998 FX 253-848-0542BLDG 1 SECOND FLOOR 1/8" = 1'-0" BLDG 1 SECOND FLOOR L:\(2) ACTIVE JOBS\X - YELM APARTMENTS - SCHUUR BROS, KORY\(5) DESIGNS\(1) FIRE ALARM\BLDG 1\YELM APTS - BLDG 1 FIRE - 07-11-2022.dwg, 7/26/2022 8:01:24 AMTOWNZEN & ASSOCIATES REVIEWED FOR CODE COMPLIANCE The plans submitted for review have been reviewed in accordance with local and state applicable standards. This does not relieve the applicant of the responsibility of compliance with the applicable codes. 4 09/13/2022 No Comments Comments Noted on drawings