Loading...
JB2019513_Yelm_Plans (22745)PROJECT FOOTAGES NEW AERIAL: 0 NEW UNDERGROUND: 117' EXISTING AERIAL/OVERLASH: 0 EXISTING UNDERGROUND: 0 TOTAL FOOTAGE: 117' OWNER / APPLICANT COMCAST CONTACT: BRIAN HOBACK; NETWORK PROJECT MANAGER MOBILE: (253) 254-1366 EMAIL: BRIAN_HOBACK@COMCAST.COM PACIFIC STORAGE PARTNERS LLC PROJECT #: 2019513 10013 D RAGT ST SE YELM, WA 98597 0 � a x `Cea51 Wyndstone Apartments Q 981h Way Southeast SeJ G �2a e° 1¢rra View St SE r°F 1� Duran) St S We SE 95lh Ave SE c 7-1 991h Ave SE Southeast O> Durant St SE V n Arctic Paws Kennel Q m A f- 99th Way Southeast E c Q Jessica Hills Photography + t L _ Cols ARNP E 1001h Ave SE Ave SE e \ `w icd Ln SE tOD9Dlir¢ St SF N o Lon erase Q Space Bear Bags Longmire St SE oDrrve Seuryeaat F ` 1Y °eeas Basketball court 0 A t a�OmaBpJtjVal W+ Tahcma Poulevard Southeast E Peel & Prep Catering Q S DESIGN BY K&B TECHNICAL SOLUTIONS P.O. BOX 2529 CLACKAMAS, OR 97015 CONTACT: BRAD ROLLINS MOBILE: (281) 923-8353 EMAIL: PERM ITS@KBMAIL.NET UNIT CODES FOR INTERNAL USE SHEETINDEX SHT DESCRIPTION CS COVER SHEET/VICINITY MAP 1 RIGHT-OF-WAY PLAN L LEGEND & TYPICALS ATTENTION: WASHINGTON LAW REQUIRES AN EXCAVATOR TO PROVIDE THE NOTICE TO A ONE -NUMBER LOCATOR SERVICE NOT LESS THAN TWO BUSINESS DAYS AND NOT MORE THAN TEN BUSINESS DAYS BEFORE THE SCHEDULED DATE FOR 7q COMMENCEMENT OF EXCAVATION, UNLESS OTHERWISE AGREED BY THE EXCAVATOR AND FACILITY OPERATORS. IF AN EXCAVATOR INTENDS TO WORK AT MULTIPLE SITES OR AT A LARGE PROJECT, THE EXCAVATOR MUST TAKE REASONABLE STEPS TO CONFER WITH FACILITY OPERATORS TO ENABLE THEM TO LOCATE UNDERGROUND K low whars below. FACILITIES REASONABLY ADVANCE OF THE START OF Call before you dig EXCAVATION FOR EACH PHASE OF THE WORK. z J w cn 00 O _M ' Q 2 <� �(D o� oelf M J LU J 00 W LL O U O � m 0, W z O ❑ u N C ❑ Y o0 E u) U N y J � eb ¢ L) m N — E U cc j Of w o m mm O a of m c E m a U ID QO U U ace N O U : o M In Y z , N o o O U) cl m =m m SHEET CS PROJECTID CMEX-51107-22745 N W E S 0 10, 20' SCALE: 1"=20' 14730 14712 Y WHEN WORKING OVER OR NEAR SIDEWALKS: PROVIDE SPOTTERS TO HOLD PEDESTRIAN TRAFFIC UNTIL CONSTRUCTION CAN BE PAUSED. OR IT IS SAFE TO PASS THROUGH THE WORK ZONE. BORE TO PLACE (1)-2" CONDUIT MIN. 36" BELOW GRADE PULL NEW CABLE THROUGH NEW CONDUIT 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR BETTER CONDITION. 2. UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS AND FIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. ATTENTION: Washington law requires an excavator to provide the notice to a one -number locator service not less than two business 3. IT IS THE CONSTRUCTION CONTRACTOR'S RESPONSIBILITY TO FIELD days and not more than ten business days before the scheduled date for commencement of excavation, unless otherwise agreed LOCATE ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. by the excavator and facility operatorsif an excavator intends to COMPLETE REPAIR OF ANY AND ALL DAMAGES INCURRED SHALL BE AT THE work at multiple sites or at a large project, the excavator must take EXPENSE OF THE CONTRACTOR. ,easonable steps to confer with facility operators to enable them to locate underground facilities reasonably in advance of the start of excavation for each nhace of the work. DIG UP AND INTERCE CONDUIT PLACED BY EXIT RIGHT-OF-WAY TI 4OG 12, 00 4 01' 9944 ,o 14827 W CO I— 6) C() Ln 00 d) UQ Q 0 W O O Z Q J 0_ Q L.L 0 M ' H Lr) _ M U O N J W H 0 1 r!') O rn� co z O 00 t tll Nm C r mrn— J U Yoo� N U N Y = LO N O U C"I w o m mm O a SHEET 1 PROJECTID CMEX-51107-22745 LINETYPES AERIAL CABLE EXISTING CONDUIT NEW CONDUIT ------------------- RIGHT-OF-WAY ROW EASEMENT ESMT PUBLIC UTILITY EASEMENT PUE PROPERTY LINE CENTERLINE FACE OF CURB FOC EDGE OF PAVEMENT EOP EDGE OF CONCRETE EOC EDGE OF GRAVEL EOG EDGE OF SIDEWALK S/w EXCAVATION LIMITS — — — — — — — — — — — SEWER S STORM SD WATER W GAS G POWER P TELEPHONE T FIBER OPTIC FO CATV CAN TRAFFIC SIGNAL TRS STREET LIGHT SLT FENCE LINE GUARD RAIL El RAILROAD TRACKS BUILDING FOOTPRINT SYMBOLS JOINT USE POLE ® POLE TAG JOINT USE POLE W/ TRANSFORMER ® POLE TAG POWER POLE W/ TRANSFORMER POLE TAG POWER POLE X POLE TAG CABLE POLE 0 POLE TAG TELEPHONE POLE 0 POLE TAG EXISTING CONDUIT RISER PROPOSED CONDUIT RISER (� EXISTING PEDESTAL EXISTING VAULT/HANDHOLE ❑V EXISTING MANHOLE MH PROPOSED PEDESTAL PROPOSED VAULT/HANDHOLE V❑ PROPOSED MANHOLE MH INLET VALVE X METER a] HYDRANT i7 POWER TRANSFORMER ❑0 STREET LIGHT POLE TRAFFIC SIGNAL POLE ❑o SIGNAL CONTROLLER CROSS WALK SIGNAL O RAILROAD SIGNAL �o TREE 0 CULVERT EXISTING SPLICE CASE PROPOSED SPLICE CASE W U ti U)Lo 00 H m U Q o M J W O } O 0 rm rnLI) U) of M z O 00Q) ❑ 0 N C @rn- Fu D YooE U5 U N y- J @ eb ¢ C) m U d.c . Z N = U ND_d w o m mm O a SHEET L PROJECTID CMEX-51107-22745 FILE NAME TIME DATE DESIGNED BY ENTERED BY CHECKED BY PROJ. ENGR. REGIONAL ADM.REVISION DATE BY SHEET OF SHEETS Washington State Department of Transportation P.E. STAMP BOX P.E. STAMP BOX DATE DATE LOCATION NO.CONTRACT NO. JOB NUMBER REGION NO. STATE FED.AID PROJ.NO. WASH PLOTTED BY PLAN REF NO FletcCo 9/18/2014 1:16:53 PM S:\Design R P& S\4-Standards\2-Plan Sheet Library\01-Published PSL\(TC) Work Zone Traffic Control\W(TC-1) One Lane, Two Way Traffic Control with Flaggers\TC-1.dgn Plot 1 TC1 TRAFFIC CONTROL PLAN LEGEND W20-1 48" 48" AHEAD WORK ROAD 48" 48" TO STOP PREPARED BE W20-7B 48" 48" W20-4 AHEAD ROAD ONE LANE 48" 48" W20-7A W20-1 48" 48" AHEAD WORK ROAD 48" 48" W20-4 AHEAD ROAD ONE LANE 48" 48" TO STOP PREPARED BE W20-7B 48" 48" W20-7A ROADWAY CONDITIONS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT INTERSECTIONS AND DRIVEWAYS. (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE URBAN STREETS 35 / 40 MPH 25 / 30 MPH 45 / 55 MPH 60 / 65 MPH 48" 48" W20-7A W20-1 48" 48" AHEAD WORK ROAD 48" 48" W20-4 AHEAD ROAD ONE LANE 48" 48" TO STOP PREPARED BE W20-7B LONGITUDINAL BUFFER SPACE = B 30 35 40 45 50 55 60 65 70 250 305 360 425 495 570 BUFFER DATA 200 THE WORK AREA. MAY BE A WORK VEHICLE STRATEGICALLY LOCATED TO SHIELD BUFFER VEHICLE ROLL AHEAD DISTANCE = R - 50/65 TAPER TANGENT 10 TO 20 NOTES: 1. 100 FEET MAX. TO 30 FEET MIN. SPEED (MPH)25 155 645 TRANSPORTABLE ATTENUATOR MANUFACTURERS RECOMMENDATION. WEIGHT SHALL BE IN ACCORDANCE WITH THE MINIMUM HOST VEHICLE WEIGHT 15,000 LBS. THE MAXIMUM LENGTH (FEET) PROTECTIVE VEHICLE REQUIRED DISTANCE NO SPECIFIED MPH SPACING (FEET) CHANNELIZATION DEVICE 35/45 25/30 10 TO 20 10 TO 20 40 60 80 SIGN SPACING = X (1) RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS RURAL ROADS, URBAN ARTERIALS, 25 MPH OR LESS »¿100’ »¿200’ »¿350’ »¿500 »¿800 2. 3. 4.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. ADDITIONAL DETAILS. FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS FOR NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT SHOULDER IS RECOMMENDED. EXTENDING THE CHANNELIZING DEVICE TAPER ACROSS ALL SIGNS ARE BLACK ON ORANGE. WITH FLAGGERS ONE-LANE, TWO-WAY TRAFFIC CONTROL NOT TO SCALE IN T E R S E C T I N G R O A D W A Y 40 MPH OR LESS) W20-7B (OPTIONAL IF 40 MPH OR LESS) W20-7B (OPTIONAL IF 40 MPH OR LESS) W20-7B (OPTIONAL IF PROTECTIVE VEHICLE CHANNELIZING DEVICES TEMPORARY SIGN LOCATION FLAGGING STATION 300’ 50’ TOX AREA WORK XMIN. 6 DEVICE 50’ TO 100’ BRMIN. 6 DEVICE 50’ TO 100’ XXXX X X X X X X MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANE Posted Speed (mph) WIDTH (feet) 25E�2'45'1 40 45 50 55 60 65 70 10 105 270 450 500 550 11 115 295 495 550 605 660 - - 12 125 320 540 600 660 720 780 840 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER Posted Speed (mph) WIDTH (feet) 25 1 30 35 40 45 50 55 60 65 70 81 40 40 60 90 120 130 150 1 160 170 1 190 10, 40 60 90 90 150 170 190 1 200 220 1 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. SIGN SPACING = X (1) FREEWAYS & EXPRESSWAYS 55 /70 MPH 1500't RURAL HIGHWAYS 60 /65 MPH 800't RURAL ROADS 45 /55 MPH 500't RURAL ROADS & URBAN ARTERIALS 35 /40 MPH 350't RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200't (2) URBAN STREETS 25 MPH OR LESS 100'! (2) (1)ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. CHANNELIZATION DEVICE SPACING (feet) TAPER TANGENT 480 IMPH 30 60 20 40 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 1 200 1 250 1 305 360 425 495 1 570 1 645 1 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HICLE WEIGHT ,000 lbs. < 45 MPH 45-55 MPH > 55 MPHL2T1. 55 MPH > 55 MPH 100, 123' 172' 150' PCMS 1 2 RIGHT 1 MILE LANE AHEAD CLOSURE 2.0 SEC 2.0 SEC FIELD LOCATE 1 MILE i IN ADVANCE OF LANE CLOSURE SIGNING. 9° NOTES RIGHT LANE 1. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. CLOSED LEGEND AHEAD 2. EXTEND DEVICE TAPER AT L/3 ACROSS SHOULDER. q TEMPORARY SIGN LOCATION 483. DEVICES SHALL NOT ENCROACH INTO THE ADJACENT LANE. W20-51`11 4. USE TRANSVERSE DEVICES IN CLOSED LANE EVERY 1000'(FT) ® TRAFFIC SAFETY DRUM (RECOMMENDED). �D SEQUENTIAL ARROW SIGN 5. DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE TRANSPORTABLE ATTENUATOR SINGLE -LANE CLOSURE FOR MULTI -LANE ROADWAYS 20'(FT). PCMS PORTABLE CHANGEABLE MESSAGE SIGN 6. ALL SIGNS ARE BLACK ON ORANGE. NOT TO SCALE FILE NAME S:1Desi n R P& SW-Standardsl2-Plan Sheet Libra 102-PSL Work in Pro ressTeml TC1-TC-17 Buffer Data table re IacementlTC-3.dgn Plot 1 TIME 8,18,31 AM —Tr FED.AID PROJ.NO. Amok Rux Rv DATE 1/312018 � PLOTTED BY Ilddelf WAS �I/ TC3� DESIGNED BY +oe x... eR ENTERED BY Washington State .... CHECKED BY coxTRnm x L-Anox Department of Transportation off PROJ. ENGR. re DATE TRAFFIC CONTROL PLAN REGIONAL ADM. REVISION DATE BY