Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
24-091 TwinStar Credit Union TI Equipment Submittal 11-15
KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DR. SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 LICENSE NO. KNIGHFP044LK Fire Sprinkler System Equipment Submittal TwinStar Credit Union - TI 1109 E Yelm Ave. Yelm, WA 98597 KFP Job #24-091 KFP Job #12-113 www.reliablesprinkler.com Features • Standard Coverage, Concealed Pendent (K2.8, 4.2, 5.6, & 8.0 [40, 60, 80, & 115 metric]) • Flat concealed cover plate available in a variety of finishes. • Available with Stainless Steel Clad cover plate (see Table I). • 3/4-inch (19 mm) cover plate adjustment. • Cover plate available with optional gasket. Product Description Model G5 series sprinklers are standard coverage, flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets. All Model G5 series sprinklers use a fusible-link operating element. The sprinklers are offered with a standard Model G5 cover plate, a Model G5 cover plate with a quick-response (QR) gasket, or a Model G5 cover plate with a standard-response (SR) gasket. Model G5 sprinklers with a gasketed cover plate are intended for use in dust free environments such as clean rooms. Model G5 sprinklers must only be used with the Model G5 cover plate listed or approved with the sprinkler. Table A provides a summary of available Model G5 series sprinklers, along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary Table A Sprinkler Model K-Factor gpm/psi1/2 (L/min/bar1/2) Cover Plate Model Listings and Approvals Sensitivity Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) G5-28 2.8 (40) G5 cULus QR 175 (12)RA3411FMSR G5 QR Gasket cULus QR G5 SR Gasket cULus, FM SR G5-42 4.2 (60) G5 cULus QR 175 (12)RA3413G5 QR Gasket G5 SR Gasket cULus SR G5-56 5.6 (80) G5 cULus QR 250 (17) RA3415 FM, LPCB, VdS, CE, UKCA SR 175 (12) G5 QR Gasket cULus QR 250 (17) G5 SR Gasket cULus SR 250 (17) FM SR 175 (12) G5-56 300 5.6 (80) G5 cULus QR 300 (21)RA4014G5 QR Gasket G5 SR Gasket cULus SR G5-80 8.0 (115) G5 cULus QR 175 (12)RA3412G5 QR Gasket G5 SR Gasket cULus SR G5-80F 8.0 (115) G5 FM SR 175 (12)RA3417G5 SR Gasket Note: Gasket material is silicone rubber, available in white only. Model G5 Cover Plate with SR Gasket Model G5 Cover Plate with QR Gasket Model G5 Cover Plate Model G5 Series Sprinklers Standard Spray, Flat Concealed Pendent Available with Gasketed Cover Plate Bulletin 034 April 2023 Model G5-56 Standard Coverage, Concealed Pendent Sprinkler SIN RA3415 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Fusible Link: Beryllium Nickel Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing washer: Nickel with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Temperature Ratings Ordinary 165°F (74°C) (Sprinkler) [135°F (57°C) (Cover Plate)] Intermediate 212°F (100°C) (Sprinkler) [165°F (74°C) (Cover Plate)] Sensitivity (See Table D) Cover Plates Model G5 Model G5 QR Gasket (cULus only) Model G5 SR Gasket (cULus and FM only) Cover Plate Finishes (See Table I) Sprinkler Wrench Model W3 Model FC Listings and Approvals cULus Listed (Light & Ordinary Hazard only) FM Approved LPCB Approved VdS Approved [165°F (74°C) only] CE Listed (2831-CPR-S2062) UKCA: 0832-UKCA-CPR-S5045 Model G5-56 Sprinkler Components and Dimensions Figure 3 Model G5-56 Sensitivity Table D Cover Plate Model Listing or Approval Agency cULus FM LPCB, VdS, CE, UKCA G5 QR SR SR G5 QR Gasket QR ---- G5 SR Gasket SR SR -- QR: Quick-response SR: Standard-response Bulletin 034 April 2023 Page 4 of 9 www.reliablesprinkler.com Installation Dimensions and Cover Plate Information Table H Cover Plate Model Cover Plate Diameter Inch (mm) Recommended Hole Diameter in Ceiling Inch (mm) Cover Plate Adjustment Inch (mm) Min. to Max. Face of Fitting to Ceiling(1) Inch (mm) Min. to Max. Dropped Deflector Distance below Ceiling Inch (mm) Cover Plate Temperature Rating °F (°C) G5 3-5/16 (84) 2-5/8 (67) 3/4 (19) 1-1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 135°F(3) (57°C) or 165°F(4) (74°C) G5 QR Gasket(2)3-11/16 (94) G5 SR Gasket(2)4 (101 mm) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 QR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model G5 QR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. 3. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 4. For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Cover plates do not carry corrosion resistant listings or approvals. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with QR sealing gasket. 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Application Model G5 series sprinklers are standard coverage, flat plate concealed pendent sprinklers. The sprinklers are intended for use in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets, as well as the requirements of the applicable approval agencies. Model G5 series sprinklers are available as either Quick-response (QR) or Standard-response (SR) depending on the approval agency and cover plate selected. Model G5 series sprinklers use Model G5 flat cover plates. Model G5 QR Gasket and G5 SR Gasket cover plates are available to limit air and dust movement through the ceiling. Listing & Approval Agencies Individual Model G5 series sprinkler may be listed or approved by the following agencies: • Underwriters Laboratories, Inc. and UL Canada (cULus) Listing Category: Sprinklers, Automatic and Open Guide Number: VNIV • FM Approvals (FM) • Loss Prevention Certification Board (LPCB) • VdS Schadenverhütung GmbH (VdS) • EC-Certificate of Conformity 0832-CPD-2062 (CE) • UKCA EN12259-1 : 1999 +A3:2006 See Table A and the individual sprinkler data sheets in this Bulletin for listings and approvals applicable to each sprinkler. Standard Finishes Special Application Finishes White Paint Chrome(4) Off-White Paint Black Paint Custom Color Paint (Specify)(3) Raw Brass (Lacquered) Bright Brass(4) Finished Bronze (4) Satin Chrome (4) Stainless Steel Clad(5) Custom Printed Cover Plate Finishes(1)(2)Table I Installation Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Data Sheets, and the requirements of applicable authorities having jurisdiction. Model G5 series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model G5 series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model G5 series sprinklers is not permitted and may damage the sprinkler. Bulletin 034 April 2023 Page 8 of 9 www.reliablesprinkler.com Replace any sprinkler or cover plate which has been painted (other than factory applied). Properly installed Model G5 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model G5 series sprinklers have holes in the cup that must remain unobstructed. Replace any sprinkler which has been damaged. A stock of spare sprinklers should be maintained to allow quick re-placement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model G5 series sprinklers may be covered by one or more of the following patents: U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent 8,776,903, U.S. Patent 9,248,327 Ordering Information Specify the following when ordering. Sprinkler • Model [G5-28] [G5-42] [G5-56] [G5-56 300] [G5-80] [G5-80F] • Temperature Rating [165°F (74°C)] [212°F (100°C)] • Threads [NPT or ISO 7-1] Cover Plate • Model [G5, G5 QR Gasket, G5 SR Gasket] • Finish (See Table I) Sprinkler Wrench • Model W3 • Model FC P/ N 9 9 9 9 9 7 0 4 2 1 Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2” square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is specified in Table J. Installation Torque Table J Sprinkler Threads Recommended Installation Torque (min. – max.) ft.lb N·m ½” NPT or ISO7-1R1/2 8-18 11-24 ¾” NPT or ISO7-1R3/4 14-20 19-27 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand, pushing and then turning the cover in the clockwise direction until it is tight against the ceiling. For Model G5 QR Gasket and Model G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt only. Do not glue the gasket in place or allow the gasket to overlap both the cover plate and the flange of the skirt. Maintenance Reliable Model G5 series sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non- operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Model FC For use with Model G5 Series sprinklers without wrench-able cap installed Wrench Model W3 For use with Model G5 Series sprinklers with wrench-able cap installed Bulletin 034 April 2023 Page 9 of 9 www.reliablesprinkler.com victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1219, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. • Series AH2-CC Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1219, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. • Sprinkler Reducers: ½" and ¾"/15 and 20 mm sprinkler connections and 5.75, 9, 13"/140, 230, 330 mm straight lengths and short, long 90º elbows. Note: The short 90° elbow is typically used with concealed sprinklers while the long 90º elbow is typically used in the installation of recessed pendent sprinklers. Low Profile long, and short 90° elbows for use with Style AB11 Bracket. • Inlet Connections: • 1"/25 mm Grooved IGS • 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • ¾"/20 mm NPT or BSPT adapter nipples available for VdS. • 1 ¼"/ 32mm BSPT adapter nipples available for LPCB. • Brackets: • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong® TechZone™ ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) Victaulic® Vic-Flex™ Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 2 victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) Connections • To adapter nipple (inlet) via • 1"/25.4 mm Grooved IGS • 1"/25.4 mm NPT or BSPT male thread • ¾"/20 mm BSPT male thread (VdS only) • 1 ¼"/32 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via ½" or ¾"/15 mm or 20 mm Minimum Bend Radius • 7"/178 mm (FM Approval) • 2"/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (½"/15mm reducer) K5.6/8,1 (S.I.), (¾"/20mm reducer) K14.0/20,2 (S.I.) • cULus (½"/15mm reducer) K8.0/11,5 (S.I.), (¾"/20mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (½"/15mm reducer) K5.6/8,1 (S.I.), (¾"/20mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 3.0 SPECIFICATIONS – MATERIAL Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Low Profile Elbows: Stainless Steel Brackets: Carbon Steel, Zinc-Plated Series AH2-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 • Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 4 victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose B 371 2 4685 A Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve Hose Length Dimensions Hose Length A B inches mm inches mm inches mm 31/790 25.3/641 31/790 36/915 31.3/794 36/915 48/1219 42.3/1073 48/1220 60/1525 54.3/1378 60/1525 72/1830 66.3/1683 72/1830 Series AH2-CC Braided Hose Hose Length A B inches mm inches mm inches mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 BA 3712 468 5 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 4.0 DIMENSIONS (C ontinued) Standard Reducer 1234 5.75"/140 mm straight reducer Optional Reducers 9.0"/229 mm straight reducer 13.0"/330 mm straight reducer 2.62"/ 66.5 mm 4.83"/ 122.7 mm 6.57"/ 166.9 mm 2.62"/ 66.5 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 6 victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings • Hard-Lid Ceilings (FM Only) Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Center Bracket 3 End Bracket *Both sizes FM/VdS/LPCB approved, cULus listed Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket *Both sizes FM/VdS/LPCB approved, cULus listed Style AB3 • Surface Mount Applications • FM Approved 3 2 1 3 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel *Both sizes FM/VdS approved, cULus listed Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket *Both sizes FM/VdS approved, cULus listed Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket *Both sizes FM/VdS approved. Style AB7 Adjustable • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) *Both sizes FM/VdS approved. 3 2 1 3 3 2 1 3 3 2 1 3 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 8 victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB8 • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket *Both sizes FM/VdS approved. Style AB9 • Hard-Lid ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket for Hat Furring Channel *Both sizes FM/VdS approved. Style AB10 • Suspended ceilings • Armstrong® TechZone™ Item Description 1 6"/152 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket *FM/VdS approved, cULus listed. 3 2 1 3 3 2 1 3 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 9 victaulic.com 4.3 DIMENSIONS (C ontinued) VicFlex Brackets Style AB11 • Suspended ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket *FM/VdS approved, cULus listed. Low Profile 2.84"/ 72 mm 1.4"/ 36 mm 1.4"/ 36 mm 4.59"/ 116 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers Style AB1, AB2, AB4, AB5 and AB10 Brackets Equivalent Length of 1"/33.7 mm Sch. 40 Pipe (C=120) Maximum Number of 90° Bends at 2"/51 mm Bend Radius inches/mm inches/mm/type feet/meters 31/775 ½"/15/Straight 16/4.9 4 ¾"/20/Straight 17/5.2 4 36/900 ½"/15/Straight 21/6.4 5 ¾"/20/Straight 23/7.0 5 48/1200 ½"/15/Straight 32/9.8 8 ¾"/20/Straight 37/11.3 8 60/1500 ½"/15/Straight 46/14.0 10 ¾"/20/Straight 46/14.0 10 72/1800 ½"/15/Straight 55/16.8 12 ¾"/20/Straight 53/16.2 12 Series AH2 Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 2"/51 mm Bend Radius inches/mm inches/mm feet/meters 31/775 ½"/15 24/7.3 4 ¾"/20 24/7.3 4 36/900 ½"/15 26/7.9 5 ¾"/20 28/8.5 5 48/1200 ½"/15 43/13.1 8 ¾"/20 42/12.8 8 60/1500 ½"/15 49/14.9 10 ¾"/20 50/15.2 10 72/1800 ½"/15 65/19.8 12 ¾"/20 63/19.2 12 19 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (C ontinued) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius Length of Stainless Steel Flexible Hose Outlet Size 1 Bend 2 Bends 3 Bends 4 Bends 5 Bends 6 Bends 7 Bends 8 Bends 9 Bends 10 Bends 11 Bends 12 Bends inches/ mm inches/ mm feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters 31/775 ½"/15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A ¾"/20 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N.A N.A N.A N.A N.A N.A 36/900 ½"/15 13.5/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A N.A N.A N.A N.A N.A N.A ¾"/20 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 48/1200 ½"/15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A ¾"/20 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 60/1500 ½"/15 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A ¾"/20 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 72/1800 ½"/15 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 ¾"/20 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 41.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 NOTES: • Values for use with 5.75"/140 mm straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 20 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4-AB9, I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 6.0 NOTIFICATIONS WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 7.0 REFERENCE MATERIALS – CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends Minimum bend radius 90° Minimum bend radius Minimum bend radius 2X Minimum bend radius OR NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB4-AB9 Minimum bend radius Minimum bend radius Minimum bend radius 2X Minimum bend radius Minimum bend radius OR 24 victaulic.com Material Specifications Gasket Materials Properties as designated in accordance with ASTM D2000 Grade “E” EPDM (Green color code) -40°F to 150°F (Service Temperature Range (-40°C to 66°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Housing Ductile Iron conforming to ASTM A536, Grade 65-45-12. Coatings Rust inhibiting paint Color: Orange (standard) Hot Dipped Zinc Galvanized (optional) U-Bolt Plated U-bolt conforming to ASTM A307 with plated hex nuts conforming to ASTM A563. Lubrication Standard Gruvlok Gruvlok Xtreme The Gruvlok Figure 7043 Branch Outlet is for direct connection of sprinkler heads and drop nipples. Just cut a hole, saddle up and fasten it with the U-bolt. The branch outlet provides an economical, quick, and easy outlet at any location along a pipe. Specially engineered to conform to the pipe O.D., the Fig. 7043 provides a leak tight reliable seal in both positive pressure and vacuum conditions. Ductile iron housings with Grade E gasket and carbon steel U-bolt (3⁄8" dia.) with flanged nuts. Ductile iron housing is available painted or galvanized . The maximum working pressure for all sizes is 175 PSI (12.1 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered Solutions™ Sales Representative. PS-03.14 page 1 PS-SUB-7043-v01 20210816 Branch Outlet Fig. 7043 Gruvlok® Branch Outlets For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: asc-es.com Note: § – For additional Bolt Torque information, see page 204. See Installation & Assembly directions on page 181. Not for use with copper systems. Gruvlok® Branch Outlets Branch Outlet Fig. 7043 Nominal Size O.D.Home Diameter Dimensions Specified Torque §Approx. Wt. EachMin. Dia.Max. Dia.A B C Take-out T Min.Max. In./DN(mm)In./mm In./mm In./mm In./mm In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./kg 1 1/4 x 1/2 1.660 x 0.840 1 3/16 1 1/4 2 1/16 3 1/2 2 7/32 1 3/8 27 33 0.8 32 x 15 42.4 x 21.3 30 32 53 89 56 35 ——0.4 1 1/4 x 3/4 1.660 x 1.050 1 3/16 1 1/4 2 1/16 3 1/2 2 7/32 1 3/8 27 33 0.8 32 x 20 42.4 x 26.7 30 32 53 89 56 35 ——0.4 1 1/4 x 1 1.660 x 1.315 1 3/16 1 1/4 2 3/16 3 1/2 2 7/32 1 1/2 27 33 0.9 32 x 25 42.4 x 33.7 30 32 56 89 56 38 ——0.4 1 1/2 x 1/2 1.900 x 0.840 1 3/16 1 1/4 2 5/32 3 1/2 2 7/32 1 3/8 27 33 0.8 40 x 15 48.3 x 21.3 30 32 55 89 56 35 ——0.4 1 1/2 x 3/4 1.900 x 1.050 1 3/16 1 1/4 2 5/32 3 1/2 2 7/32 1 3/8 27 33 0.8 40 x 20 48.3 x 26.7 30 32 55 89 56 35 ——0.4 1 1/2 x 1 1.900 x 1.315 1 3/16 1 1/4 2 9/32 3 1/2 2 7/32 1 1/2 27 33 0.9 40 x 25 48.3 x 33.7 30 32 58 89 56 38 ——0.4 2 x 1/2 2.375 x 0.840 1 3/16 1 1/4 2 1/2 3 7/8 2 7/32 1 5/8 27 33 0.8 50 x 15 60.3 x 21.3 30 32 64 98 56 42 ——0.4 2 x 3/4 2.375 x 1.050 1 3/16 1 1/4 2 1/2 3 7/8 2 7/32 1 5/8 27 33 0.8 50 x 20 60.3 x 26.7 30 32 64 98 56 42 ——0.4 2 x 1 2.375 x 1.315 1 3/16 1 1/4 2 5/8 3 7/8 2 7/32 1 3/4 27 33 0.9 50 x 25 60.3 x 33.7 30 32 67 98 56 45 ——0.4 2 1/2 x 1/2 2.875 x 0.840 1 3/16 1 1/4 2 11/16 4 3/8 2 7/32 2 27 33 0.8 65 x 15 73.0 x 21.3 30 32 69 111 56 51 ——0.4 2 1/2 x 3/4 2.875 x 1.050 1 3/16 1 1/4 2 11/16 4 3/8 2 7/32 2 27 33 0.9 65 x 20 73.0 x 26.7 30 32 69 111 56 51 ——0.4 2 1/2 x 1 2.875 x 1.315 1 3/16 1 1/4 2 13/16 4 3/8 2 7/32 2 1/8 27 33 1.0 65 x 25 73.0 x 33.7 30 32 72 111 56 54 ——0.5 PS-03.14 page 2 PS-SUB-7043-v01 20210816 asc-es.com Branch Outlets / Installation Specified Bolt Torque The nuts must be tightened alternately and evenly until fully tightened. Caution: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure, battery strength and operational variations. CAUTION: Proper torquing of the U-bolts is required to obtain the specified performance. Over-torquing the U-bolts may result in damage to the U-bolt and/or casting which could result in lower pressure retention capabilities, lower bend load capabilities, pipe joint leakage and pipe joint separation. Pipe joint separation may result in significant property damage and serious injury. 1 Pipe Preparation & Gasket Lubrication Cut a 13⁄16" hole in the pipe and remove any burrs. Be sure to remove the slug from inside the pipe. Clean the gasket sealing surface within 5⁄8" of the hole and visually inspect the sealing surface for defects that may prevent proper sealing of the gasket. Remove the gasket from the housing and apply a thin layer of Gruvlok® lubricant to the back surface of the gasket. Be careful that foreign particles do not adhere to the lubricated surfaces. Insert the gasket back into the outlet housing making sure the tabs in the gasket line up with the tab recesses in the housing. 2 Gasket Installation Lubricate the exposed surface of the gasket with Gruvlok lubricant. 3 Alignment Align the outlet housing over the pipe hole making sure that the locating collar is in the pipe hole. 4 Housing Assembly Attach the U-bolt from the other side and fasten the nuts finger tight. 5 Tighten Nuts Making sure the fitting is properly located over the pipe hole, tighten the nuts alternately and evenly to the specifed torque of 27 to 33 Lbs.-Ft. (37 to 45 N-m). 6 Assembly is Complete Visually inspect the assembly, the gasket will extrude out from under the housing. ALWAYS USE A GRUVLOK LUBRICANT FOR PROPER BRANCH OUTLET ASSEMBLY Thorough lubrication of the gasket is essential to assist the gasket into the proper sealing position. Fig. 7043 Branch Outlet PS-03.14 page 3 PS-SUB-7043-v01 20210816 1 2 3 4 56