Loading...
Circle K - Yelm (Yelm & Killion), WA - Architectural OTPABBREVIATIONS & = AND L = ANGLE @ = AT ℄= CENTERLINE ∅= DIAMETER OF ROUND # = POUND OR NUMBER (E) = EXISTING (R) = RELOCATED (N) = NEW A.B. = ANCHOR BOLT A.F.F. = ABOVE FINISH FLOOR AGGR. = AGGREGATE AL. = ALUMINUM APPROX. = APPROXIMATE ARCH. = ARCHITECTURAL ASPH. = ASPHALT BD. = BOARD BITUM. = BITUMINOUS BLDG. = BUILDING BLKG. = BLOCKING BM. = BEAM BOT. = BOTTOM BW = BACK OF WALK CAB. = CABINET CEM. = CEMENT CER. = CERAMIC C.I. = CAST IRON C.J. = CONTROL JOINT CLG. = CEILING CLR./CL. = CLEAR COL. = COLUMN CONC. = CONCRETE CONSTR. = CONSTRUCTION CONT. = CONTINUOUS CTSK. = COUNTERSUNK CNTR. = COUNTER CTR. = CENTER DEPT. = DEPARTMENT DET. = DETAIL DIA. = DIAMETER DIM. = DIMENSION DISP. = DISPENSER DN. = DOWN DR. = DOOR D.S. = DOWNSPOUT DWG. = DRAWING E = EAST EA. = EACH EL. = ELEVATION ELEC. = ELECTRICAL EQ. = EQUAL EXP. = EXPANSION EXT. = EXTERIOR F.F = FLOOR FINISH FDN. = FOUNDATION FG = FINISH GRADE FIN. = FINISH FL. = FLOOR FLASH'G = FLASHING FLUOR. = FLUORESCENT F.O.C. = FACE OF CONCRETE F.O.F. = FACE OF FINISH F.O.S. = FACE OF SHEATHING F.O.P. = FACE OF SIP PANEL F.R.P. = FIBERGLASS REINFORCED PANEL F.S. = FLOOR SINK FT. = FOOT OR FEET FTG. = FOOTING FURR. = FURRING FUT. = FUTURE G.A. = GAUGE GALV. = GALVANIZED GL. = GLASS GR. = GRADE GB = GRADE BREAK GSM = GALVANIZED SHEET METAL GYP. = GYPSUM GYP.BD. = GYPSUM BOARD H.B. = HOSE BIBB HDWE. = HARDWARE H.M. = HOLLOW METAL HORIZ. = HORIZONTAL HR. = HOUR HGT. = HEIGHT IE = INVERT ELEVATION I.D. = INSIDE DIAMETER INSUL. = INSULATION INT. = INTERIOR JT. = JOINT LAM. = LAMINATE LAV. = LAVATORY LIP = EDGE OF SWALE OR GUTTER MAX. = MAXIMUM MECH. = MECHANICAL MEMB. = MEMBRANE MFR. = MANUFACTURER MIN. = MINIMUM MISC. = MISCELLANEOUS M.O. = MASONRY OPENING MTD. = MOUNTED MUL. = MULLION N. = NORTH N.I.C. = NOT IN CONTRACT NO. OR # = NUMBER NOM. = NOMINAL N.T.S. = NOT TO SCALE O.C. = ON CENTER O.D. = OUTSIDE DIAMETER OPNG. = OPENING OPP. = OPPOSITE PB = LEVEL PAVEMENT AT DISPENSER PIT BOX PL. = PLATE P.LAM. = PLASTIC LAMINATE PLYWD. = PLYWOOD P.O.C. = POINT OF CURVATURE P.O.S. = POINT OF SALE R OR RAD. = RADIUS R.D. = ROOF DRAIN REF. = REFERENCE REINF. = REINFORCED REQ'D = REQUIRED RM. = ROOM R.O. = ROUGH OPENING R.O.W. = RIGHT OF WAY SCHED. = SCHEDULE SECT. = SECTION SHT. = SHEET SIM. = SIMILAR SIP = STRUCTURAL INSULATED PANEL SPEC. = SPECIFICATION SQ. = SQUARE S.ST. = STAINLESS STEEL STD. = STANDARD STL. = STEEL STOR. = STORAGE STRL. = STRUCTURAL SYM. = SYMMETRICAL T.C. = TOP OF CURB TG = TOP OF GRATE T.& G. = TONGUE & GROOVE THK. = THICK TI = TOP OF ISLAND T.O. = TOP OF TOW = TOP OF WALL TP = TOP OF PAVEMENT TS = TOP OF SLAB TW = TOP OF WALK TYP. = TYPICAL UNF. = UNFINISHED U.O.N. = UNLESS OTHERWISE NOTED VERT = VERTICAL V.I.F. VERIFY IN FIELD V.I.F. VERIFY IN FIELD W/ = WITH W.C. = WATER CLOSET WD. = WOOD W/O = WITHOUT WP. = WATERPROOF WSCT. = WAINSCOT WT. = WEIGHT PROJECT TEAM OWNER 1122 W. WARNER RD. TEMPE, AZ 85284 CIRCLE K STORES INC. ATTN: JIM EDWARDS TEL: (602) 721 6533 E MAIL: jim.edwards@circlek.com ARCHITECT 11921 FREEDOM DR. #1110 RESTON, VA 20190 RETAIL DESIGN COLLABORATIVE AOR: SEAN SLATER ATT: RASHMI MEHADIA CIVIL ENGINEER 1201 THIRD AVE, SUITE 2800 SEATTLE, WA 98101 KIMLEY HORN AND ASSOCIATES, INC. ATT: LIZ WILLMOT, PE TEL: (206) 677 8610 E MAIL: Liz.willomot@kimley horn.com LANDSCAPE ARCHITECT 1201 THIRD AVE, SUITE 2800 SEATTLE, WA 98101 KIMLEY HORN AND ASSOCIATES, INC. ATT: LIZ WILLMOT, PE TEL: (206) 677 8610 E MAIL: Liz.willomot@kimley horn.com STRUCTURAL ENGINEER 930 CENTRAL STREET KANSAS CITY, MO 64105 JOHNSTON BURKHOLDER ASSOCIATES BRIAN W. MAKOVEC TEL: (816) 421 4200 E MAIL: makovec@baengr.com ELECTRICAL ENGINEER 1805 N. 2ND ST. SUITE 5274 ROGERS, AR 72756 BENCHMARK GROUP ATTN: JASON C. ADAMS P.E. TEL: (479) 636 5004 E MAIL: jca@teamofchoice.com MECH/PLUMB ENGINEER 1805 N. 2ND ST. SUITE 5274 ROGERS, AR 72756 BENCHMARK GROUP ATTN: JASON M. SCATES, PE TEL: (479) 636 5004 E MAIL: jms@teamofchoice.com FUEL CANOPY STRUCT. ENGINEER P.O. BOX F. CASSIVILLE, MO 65625 AWNING COMPANIES ATTN: STEVEN WILLIAMS SCHAUB TEL: (417) 847 3131 TEL: (703) 659 8252 EMAIL: rashmi.mehadia@rdcollaborative.com SUPER STRUCTURE ENGINEER 8180 CORPORATE PARK DR. SUITE 235, CINCINNATI, OHIO 45242 PINNACLE ENGINEERING ATT: MICHAEL STREICHER, PE TEL: (513) 984 1663 E MAIL: projects@pinneng.com PROJECT ADDRESS: NWC YELM AVENUE & KILLION ROAD, YELM WA 98597 PROJECT NAME: CIRCLE K CONVENIENCE STORE, FUEL & DIESEL PUMPS PROJECT DESCRIPTION: PROPOSAL FOR A NEW CONVENIENCE STORE WITH ASSOCIATED FUEL SALES CONSISTING OF A 5,200 S.F.CONVENIENCE STORE AND A 4,608 S.F.FUEL CANOPY WITH [7]FUEL PUMPS. THE CONVENIENCE STORE WILL SELL BEER & WINE FOR OFFSITE CONSUMPTION. THE FACILITY WILL OPERATE 24 HOURS. PARCEL NUMBER:21724130100 PARCEL/SITE AREA:2.35 AC / ±102,366 S.F. EXISTING ZONING:C 1 COMMERCIAL GENERAL PLAN AND LAND USE DESIGNATION:COMMERCIAL MAX. BUILD. HEIGHT:23' 0" PROVIDED (40' 0" ALLOWED) MAX. CANOPY HEIGHT:18' 6" PROVIDED (55' 0" ALLOWED) GROSS C STORE AREA: C STORE AREA: 5,200 S.F. ENTRY CANOPY AREA; 218 S.F. TOTAL GROSS C STORE AREA 5,418 S.F. GROSS FUEL CANOPY: . . . . . . . . . . . . . . . .4,608 S.F. TOTAL GROSS C STORE + FUEL CANOPY AREA . . . . . . . . . 10,026 S.F. ALLOWABLE AREA (C STORE WITHOUT SPRINKLER) . . . . 9,000 S.F. (COMPLIES) ALLOWABLE AREA (FUEL CANOPY WITHOUT SPRINKLER) . . 8,500 S.F. (COMPLIES) GROSS LOT COVERAGE: GROSS BLDG. AREA/SITE AREA: 5,418 S.F. / ±102,366 S.F. = 5.29 % CONSTRUCTION TYPE (BUILDING): VB SPRINKLER IS NOT REQUIRED BY DEFAULT CONSTRUCTION TYPE (FUEL CANOPY): II B SPRINKLER IS NOT REQUIRED BY DEFAULT OCCUPANCY: M (MERCANTILE)BUILDING + CANOPY PARKING REQUIRED: 5,200 SF/250 = 21 PARKING STALLS (INCLUDING 1 REQ'D ACCESSIBLE STALL) PARKING PROVIDED: 21 STALLS (INCLUDING 1 ACCESSIBLE STALL) BICYCLE PROVIDED:2 BICYCLE RACKS PROVIDED LOADING PROVIDED: 3 TRUCK SPACES (14' X 58' 9") CONVENIENCE STORE BUILDING AREA: 1. ACCESSORY STORAGE AREA, MECHANICAL EQUIPMENT ROOM. A. AREA OF BACKROOM: = 571 S.F. B. AREA OF UTILITY/STORAGE: = 103 S.F. C. AREA OF WALK IN COOLER: = 803 S.F. D. CASHIER & PREP AREA: = 454 S.F. = 1,931 S.F. 2. SALES AREA: = 2,584 S.F. 3. AUXILL IARY AREAS (HALLWAY, RESTROOMS): = 685 S.F. TOTAL BUILDING AREA: 5,200 S.F. EXITING: 1. ACCESSORY STORAGE AREA, MECHANICAL EQUIPMENT ROOM: 1,931 S.F. /300 = 7 OCC. 2. SALES AREA 2,584 S.F. / 60 = 44 OCC. 3. AUXILIARY AREAS (HALLWAYS, RESTROOMS) 685 S.F. / 60 = 12 OCC. TOTAL OCCUPANT LOAD = 63 OCCUPANTS EXITS REQUIRED: 2 EXITS PROVIDED: 4 EGRESS WIDTH REQUIRED: 63 x 0.2 = 12.6" EGRESS WIDTH PROVIDED: 34" X 3 + 42" X 1 = 144" CODES USED: 2021 WASHINGTON STATE BUILDING CODE 2021 WASHINGTON STATE FIRE CODE 2021 WASHINGTON STATE MECHANICAL CODE 2021 WASHINGTON STATE PLUMBING CODE 2021 WASHINGTON STATE COMMERCIAL ENERGY CODE 2023 WASHINGTON STATE ELECTRICAL CODE, 2023 NFPA 70 2017 WASHINGTON STATE ACCESSIBILITY CODE, A117.1, 2017 PROJECT DATA GENERAL BIDDING NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION AND SUBMITTALS TO UTILITY COMPANIES FOR THIS PROJECT. 2. CONTRACTOR SHALL PROVIDE UNIT PRICING TO OWNER ON ALL PHONE, GAS, TELECOMMUNICATION, AND POWER COST FOR THIS PROJECT INCLUDING BUT NOT LIMITED TO TRENCHING, CONDUIT, LINE PULLS, CONNECTION, ETC. 3. CONTRACTOR SHALL BID THIS PROJECT COMPLETELY WITH NO EXCEPTIONS UNLESS INSTRUCTED BY OWNER. CONTRACTOR SHALL PROVIDE ALLOWANCES ON ANY ITEM THAT CAN NOT BE RESOLVED DURING THE BID PROCESS. 4. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONNECTIONS, EXISTING PLUMBING TAPS, ELECTRICAL PANEL LOCATIONS, GAS METERS AND MECHANICAL EQUIPMENT AGAINST THE PLANS AND REPORT ANY DISCREPANCIES DURING THE BID PROCESS 5. CONTRACTOR SHALL BE RESPONSIBLE FOR CLARIFICATION OF DOCUMENTS. SHOULD A BIDDER FIND DISCREPANCIES IN OR OMISSIONS FROM THE DRAWINGS OR DOCUMENTS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHALL NOTIFY THE ARCHITECT FIVE DAYS OR MORE BEFORE DATE SET TO RECEIVE BIDS, WHO WILL SEND, AFTER CONSIDERATION, IDENTICAL INSTRUCTIONS TO ALL BIDDERS. IN THE EVENT CLARIFICATION IS DEEMED NECESSARY, NEITHER OWNER NOR ARCHITECT WILL BE RESPONSIBLE FOR ORAL INSTRUCTIONS. 6. GENERAL CONTRACTOR SHALL VERIFY GOVERNING REQUIREMENTS PRIOR TO BID AND ALL REQUIREMENTS FOR A COMPLETE FIRE SPRINKLER SYSTEM ARE TO BE INCLUDED IN BID, IF BUILDING IS SPRINKLERED 7. THE ARCHITECT ASSUMES THE GENERAL CONTRACTOR HAS INCLUDED IN HIS BID/PRICING THE HIGHEST QUALITY AND GREATEST QUANTITY FOR THE PURPOSE OF RESOLVING ANY CONFLICTS IN THE CONSTRUCTION DOCUMENTS WHICH ARE IMPLIED OR UNDEFINED. 8. ALL BID NUMBERS SHOULD INCLUDE BREAKDOWN OF UNIT PRICE. 9. CONTRACTOR TO BASE BID ON PROVIDING 3 FIRE EXTINGUISHERS. CLIMATE ZONE: 4C GENERAL (PRESCRIPTIVE METHOD) C402.1 ITEM 2 C402.1; C402.2 & C402.1.3 PER TABLE C402.1.3 R VALUE BASED METHOD ROOF INSULATION REQUIRED R30ci; PROVIDED R33ci WOOD FRAMED EXTERIOR WALLS = REQUIRED R20; PROVIDED R24.7 UNHEATED SLABS REQUIRED R 10 FOR 24" BELOW; PROVIDED R 10 FOR 24" BELOW PER TABLE C402.3 FOR SINGLE PLY SYSTEM: TPO (THERMOPLASTIC POLYOLENM MEMBRANE) ROOFING SYSTEM OVER SIP ROOF PANEL. WHITE MECHANICALLY FASTENED SOLAR REFLECTANCE: .55 THERMAL EMITTANCE: .75 PER TABLE C402.4 U FACTOR STOREFRONT REQUIRED U 0.38; PROVIDED U 0.27 ENTRANCE DOOR REQUIRED U 0.77; PROVIDED U 0.27 OTHER DOORS REQUIRED U 0.45 ; PROVIDED U 0.27 STOREFRONT KAWNEER TRIFAB 451UT FRAMING SYSTEM OR EQUAL 1. COORDINATE ALL EQUIPMENT PLACEMENTS, SUPPORTS, AND CONNECTIONS WITH EQUIPMENT SUPPLIERS. 2. COMPLY WITH ALL LOCAL BUILDING CODES, ORDINANCES, AND CONSTRUCTION STANDARDS. 3. FOR COMPLETE MECHANICAL SYSTEM LOCATIONS AND SIZES OF SUPPLY, RETURN, AND DUCTWORK, SEE MECHANICAL PLANS. 4. FOR COMPLETE ELECTRICAL SYSTEM LOCATIONS AND SIZES OF LIGHTING, OUTLETS, PHONES, AND ELECTRICAL PANELS, SEE ELECTRICAL PLANS. 5. FOR COMPLETE PLUMBING LOCATIONS, SIZES, AND FIXTURE TYPES, SEE PLUMBING PLANS. 6. ALL NEW WALLS SHALL BE TAPED, TEXTURED, AND PAINTED PER OWNERS COLOR SELECTION / SPECIFICATIONS. 7. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. 8. ONE SET OF STAMPED, APPROVED DRAWINGS MUST BE MAINTAINED ON SITE AND MADE AVAILABLE TO CITY INSPECTORS ON DEMAND. 9. ALL WORK SHALL BE FURNISHED AND INSTALLED IN COMPLIANCE WITH APPLICABLE BUILDING CODES AND THE HIGHEST PROFESSIONAL WORKMANSHIP OF THE BUILDING TRADES PERFORMING UNDER THIS CONTRACT. 10. ALL REQUIRED CONTROLLED INSPECTIONS SHALL COMPLY WITH THE LOCAL BUILDING CODES. 11. ALL DIMENSIONS SHALL BE FIELD CHECKED, CHECKED IN SHOP, AND VERIFIED PRIOR TO THE PERFORMANCE OF ANY WORK, AND THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES IN WRITING BEFORE PERFORMANCE OF THE WORK. 12. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND SHALL BE RESPONSIBLE FOR THE SCHEDULING OF THE WORK. 13. ELECTRICAL SYSTEMS SHALL BE INSTALLED PER N.E.C. AND IN ACCORDANCE WITH ALL APPLICABLE UTILITY COMPANY SPECIFICATIONS AND MUNICIPAL JURISDICTIONAL CODES. 14. ALL PLUMBING AND ELECTRICAL PIPING CONDUIT SHALL BE CONCEALED EXCEPT AS OTHERWISE SPECIFIED. 15. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN WASHINGTON STATE AND SUBMITTED TO THE ARCHITECT. 16. COORDINATION OF PLANS AND SPECIFICATIONS: THE GENERAL CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION. HE SHALL IMMEDIATELY NOTIFY THE ARCHITECT, THE ARCHITECT WILL THEN MAKE SUCH CORRECTIONS AND INTERPRETATIONS AS MAY BE DEEMED NECESSARY FOR FULFILLING THE INTENT OF THE PLANS AND SPECIFICATIONS. 17. PROVIDE METAL ACCESS DOORS TO DUCTS AND OTHER MECHANICAL/ELECTRICAL EQUIPMENT THROUGH SPACES, OR CEILINGS AS REQUIRED BY MECHANICAL/ELECTRICAL DRAWINGS AND THE APPLICABLE REQUIREMENTS OF THE BUILDING CODES (BUILDING, MECHANICAL, ELECTRICAL). 18. PROPER STANDARDS OF CONSTRUCTION SHALL BE USED AS RECOMMENDED AS ACCEPTABLE STANDARDS IN THE INDUSTRY FOR ALL CONSTRUCTION EVEN IF NOT SPECIFIED IN DETAIL. 19. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. 20. PRIOR TO CONSTRUCTION, THE GENERAL CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR THE CORRECTNESS OF ALL DIMENSIONS. 21. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE, LOCATE AND CONFIRM ALL UNDERGROUND/ OVERHEAD PLUMBING AND ELECTRICAL STUB UPS. 22. GENERAL CONTRACTOR TO CAULK AND SEAL ALL EXPANS ION JOINTS AT ALL INTERIOR CONCRETE PRIOR TO FLOORING. 23. ALL EXPOSED UNFINISHED METAL AND WOOD SHALL BE PAINTED AS PER SPECIFICATION, PAINT TO MATCH ADJACENT COLOR. 24. GENERAL CONTRACTOR SHALL ENCLOSE, SEAL, AND COVER ALL PIPE, CONDUIT, DUCT, AND STRUCTURAL PENETRATIONS IN ALL WALLS. 25. UNLESS OTHERWISE NOTED, DIMENSIONS ARE TO THE FACE OF MASONRY, FACE OF CONC. AND THE FACE OF SHEATHING. 26. IN THE EVENT OF DISCREPANCIES BETWEEN ANY DRAWINGS AND/OR SPECIFICATIONS, THE MORE RESTRICTIVE CONDITION SHALL BE DEEMED AS THE CONTRACT REQUIREMENT, UNLESS OTHERWISE STATED. 27. GENERAL CONTRACTOR TO MAINTAIN ROAD CLEANLINESS DURING CONSTRUCTION. GENERAL NOTES HEALTH DEPT. NOTES TO GC 1. WALK IN UNIT WALLS, CEILING, AND FLOOR/WALL JUNCTURES SHALL BE METAL OR EQUAL AND PROPERLY COVED. 2. FLASH, TRIM, OR CAULK SPACES BETWEEN WALK IN UNIT AND ADJACENT WALLS. 3. WALK IN UNITS OR OTHER LARGE EQUIPMENT/SURFACES WITH SPACES 30 INCHES OR LESS IN HEIGHT BETWEEN THE TOP SURFACES AND THE CEILING REQUIRE FLASHING OR CLOSING OFF IN A CLEAN, TIGHT VERMIN PROOF MANNER. 4. ALL WOOD SHELVING OR WOODWORK SHALL BE SANDED SMOOTH, FREE OF OPEN JOINTS AND SEALED OR PAINTED TO A SMOOTH, FINAL FINISH. 5. PROVIDE AN APPROVED SMOOTH, COVE BASE (3/8" RADIUS OR GREATER) AT WALL AND FLOOR JUNCTURES AND EQUIPMENT BASES THROUGHOUT THE ESTABLISHMENT. 6. PROVIDE AN ADDITIONAL WATER LINE AT THE MOP SINK/UTILITY AREA TO SUPPLY CHEMICAL DISPENSERS. DO NOT USE THE MOP SINK FAUCET. Y VALVES AND DOWNSTREAM SHUT OFF DEVICES ARE NOT PERMITTED ON SINK FAUCETS OR CHEMICAL DISPENSERS. 7. ALL CONSTRUCTION SHALL MEET CURRENT COUNTY HEALTH CODE REQUIREMENTS. CIRCLE K GENERAL NOTES UNDER NO CIRCUMSTANCES WILL CIRCLE K ALLOW A CHANGE OF SUPERINTENDENTS DURING THE PROJECT(S). DEFERRED SUBMITTALS DEFERRED SUBMITTALS: (PER 2021 WBC) DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM. G.C. WILL FORWARD DESIGN PROFESSIONAL'S APPROVED DEFERRED SUBMITTAL TO THE BUILDING OFFICIAL FOR APPROVAL PRIOR TO INSTALLATION.A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING SHALL BE MADE ON THE DEFERRED SUBMITTAL. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. DEFERRED SUBMITTAL ITEMS: WOOD TRUSSES SIGNAGE SOIL TREATMENT CONTRACTOR TO PROVIDE AN EPA REGISTERED TERMITICIDE COMPLYING WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION, IN AN AQUEOUS SOLUTION FORMULATED TO PREVENT TERMITE INFESTATION. PROVIDE QUANTITY REQUIRED FOR APPLICATION AT THE LABEL VOLUME AND RATE FOR THE MAXIMUM TERMITICIDE CONCENTRATION ALLOWED FOR EACH SPECIFIC USE, ACCORDING TO PRODUCT'S EPA REGISTERED LABEL. PROJECT SITE ELEVATION INDICATOR REVISION MARK KEYED NOTE ROOM NUMBER IDENTIFICATION CEILING HEIGHT WALL SECTION DOOR NUMBER IDENTIFICATION INTERIOR PARTITION TYPE WINDOW NUMBER IDENTIFICATION DETAIL MARK ROOM NAME XXX DOOR # XX XX Sheet X # # Sheet x' x" x SYMBOL LEGEND CIRCLE K PROTOTYPE DATA PROTOTYPE REVISION :5200 R3.4.1 05/16/23 CONSTRUCTION BULLETINS : • 2305 COOLER RETAIL SHELVING • 2306 FLOOR TILE VE • 2309 TPO SPECIFICATION • 2401 COFFEE 2.0 • 2402 FFF ISLAND REVISION • 2404 BEVERAGE WALL DRAIN ACCESS PANELS • 2405 SIDE DOOR • 2406 GONDOLA END CAPS • 2308 AUGUST EQUIPMENT CHANGES (A, B, C, E, F) REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PERMIT SET PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC G1.0 PROJECT NUMBER: 24212 ZONING #:XXXX, ENG. #:XXXX; BLDG. #:XXXX FIRE PERMIT #, HEALTH PERMIT # COVER SHEET AND PROJECT INFORMATION STORE #XXXX NWC YELM AV & KILLION RD YELM, WA 98597 CIRCLE K CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 NUMBER NAME I S S U E A N D R E V I S I O N S P E R M I T S E T 1 1 / 1 2 / 2 4 GENERAL G1.0 COVER SHEET AND PROJECT INFORMATION ● SITE PLAN SD1.1 SITE PLAN ● SD1.2 SITE DETAILS ● SD1.3 SITE DETAILS ● CIVIL C0.0 COVER SHEET C1.0 GENERAL NOTES C2.0 DEMOLITION PLAN C3.0 EROSION SEDIMENT CONTROL PLAN C3.1 EROSION SEDIMENT CONTROL DETAILS C4.0 SITE PLAN C4.1 TRUCK ROUTING PLAN C5.0 GRADING PLAN C5.1 GRADING PLAN C5.2 TYPICAL DRAINAGE CROSS SECTION C6.0 UTILITY PLAN C7.0 CONSTRUCTION DETAILS C7.1 CONSTRUCTION DETAILS C7.2 CONSTRUCTION DETAILS C7.3 CONSTRUCTION DETAILS C7.4 CONSTRUCTION DETAILS C7.5 CONSTRUCTION DETAILS LANDSCAPE L5.0 LANDSCAPE PLAN L5.1 LANDSCAPE NOTES L5.2 LANDSCAPE DETAILS IR4.0 IRRIGATION PLAN IR4.1 IRRIGATION NOTES IR4.2 IRRIGATION DETAILS ARCHITECTURAL A1.0 EGRESS/ ACCESSIBILITY FLOOR PLAN ● A1.1 ACCESSIBLITY STANDARDS, NOTES/DETAILS ● A1.2 FLOOR PLAN ● A1.3 DIMENSIONED FLOOR PLAN, WALL TYPES, AND ENLARGED RESTROOM ● A1.4 EQUIPMENT PLAN ● A1.5.1 EQUIPMENT LIST ● A1.5.2 EQUIPMENT LIST ● A1.5.3 EQUIPMENT LIST ● A1.6 REFLECTED CEILING PLAN ● A1.7 ROOF PLAN AND DETAILS ● A1.8 FLOOR PENETRATION PLAN ● A1.9 SECURITY SYSTEM FLOOR PLAN ● A1.10 FLOOR FINISH PLAN ● A1.11 WALL FINISH PLAN AND FINISH SCHEDULE ● A2.1 EXTERIOR ELEVATIONS ● A3.1 INTERIOR ELEVATIONS ● A3.2 INTERIOR ELEVATIONS ● A3.3 INTERIOR ELEVATIONS ● A4.0 BUILDING SECTIONS ● A5.1 WALL SECTIONS ● A5.2 WALL SECTIONS ● A6.0 ROOM KEY PLAN, DOOR/ WINDOW SCHEDULE & TYPES, AND NOTES ● A6.1 EXTERIOR ARCHITECTURAL DETAILS ● A8.1 ARCHITECTURAL DETAILS (EXTERIOR)● A8.2 ARCHITECTURAL DETAILS (EXTERIOR/INTERIOR)● A8.3 EXTERIOR ARCHITECTURAL DETAILS ● A9.1 INTERIOR ARCHITECTURAL DETAILS ● A9.2 INTERIOR ARCHITECTURAL DETAILS ● A9.3 PILASTER DETAILS ● CA 1 FUEL CANOPY PLAN ● CA 2 FUEL CANOPY ELEVATIONS ● CA 3 FUEL CANOPY COLUMN DETAILS ● STRUCTURAL S0.1 GENERAL NOTES ● S0.2 DIAGRAMS AND SCHEDULES ● S0.3 TABLE OF SPECIAL INSPECTIONS ● S1.0 FOUNDATION PLAN ● S1.1 ROOF FRAMING PLAN ● S2.0 FOUNDATION DETAILS ● S2.1 FOUNDATION DETAILS ● S2.2 FOUNDATION DETAILS ● S3.0 ROOF FRAMING DETAILS ● MECHANICAL M1.1 MECHANICAL FLOOR PLAN ● M1.1.1 MECHANICAL ROOF PLAN ● M1.2 MECHANICAL DETAILS (1 OF 3)● M1.2.1 MECHANICAL DETAILS (2 OF 3)● M1.2.2 MECHANICAL DETAILS (3 OF 3)● M1.2.3 MECHANICAL SCHEDULES ● M1.2.4 MECHANCIAL NOTES ● M1.2.5 ENERGY MANAGEMENT SYSTEM ● M1.3 MECHANICAL SPECIFICATIONS ● M1.4 CO2 LAYOUT PLAN AND NOTES ● M1.5 CO2 CUT SHEETS ● PLUMBING P1.1 PLUMBING ROOF PLAN ● P1.1.1 PLUMBING FLOOR PLAN WASTE AND VENT ● P1.1.2 PLUMBING FLOOR PLAN DOMESTIC WATER ● P1.2 PLUMBING RISER ● P1.3 PLUMBING SCHEDULES AND DETAILS ● P1.4 PLUMBING SPECIFICATIONS ● ELECTRICAL E0.0 ELECTRICAL COVERSHEET AND LEGEND ● E0.1 ELECTRICAL SPECIFICATIONS ● E1.0 ELECTRICAL SITE PLAN ● E1.1 ELECTRICAL SITE DETAILS ● E1.2 ELECTRICAL SITE PHOTOMETRIC PLAN ● E1.3 EXTERIOR LIGHT FIXTURE CUT SHEETS ● E2.0 ELECTRICAL FLOOR PLAN ● E4.0 ROOF POWER PLAN ● E5.0 LIGHTING PLAN ● E5.1 IECC COMPLIANCE REPORT ● E6.0 CALCULATIONS AND SCHEMATICS ● E7.0 PANEL SCHEDULES ● E7.1 PANEL SCHEDULES ● FUEL CANOPY CS1 CANOPY FOUNDATION PLAN ● CS2 CANOPY ROOF PLAN & DETAILS ● AB1 CANOPY FOUNFATION SECTIONS AND DETAILS ● FUEL PLAN TK001 COVER SHEET ● TK002 GENERAL NOTES ● TK006 EQUIPMENT LIST ● TK007 EQUIPMENT LIST ● TK101 TANK & PIPING DETAILS ● TK102 SCHEMATIC WIRING, PIPING & DETAILS ● TK201 STANDARD TANKS ● TK301 TYPICAL UST PLAN AND SECTIONS ● TK500 TANK SUMP DETAILS ● TK501 TANK SUMP DETAILS ● TK502 TANK TOP HARDWARE DETAILS ● TK503 DISPENSER SUMP DETAILS ● TK503.1 DISPENSER SUMP DETAILS ● TK504 DUEL SYSTEM DETAILS ● TK505 FUEL SYSTEM DETAILS ● SHEET INDEX OCCUPANT LOAD FIXTURE TYPE FIXTURES REQUIRED FIXTURES PROVIDED SERVICE SINK WATER CLOSETS WATER CLOSETS URINALS LAVATORIES LAVATORIES PER WPC, WBC, AND TABLE 2902.1 FIXTURES PER PERSON 1 MALE: 32 FEMALE: 32 1 500 1 0 1 1 1 1 0 0 0 1 750 1 500 1 750 TOTAL:63 1 2 2 2 4 2 BUILDING ENVELOPE REQ'TS NUMBER NAME I S S U E A N D R E V I S I O N S P E R M I T S E T 1 1 / 1 2 / 2 4 W0.0 COVER PAGE ● W0.1 GENERAL NOTES ● W0.2 GENERAL NOTES ● W0.3 GENERAL NOTES ● W1.0 WALL PLAN ● W1.1 HOLD DOWN PLAN ● W2.0 ELEVATIONS ● W2.1 ELEVATIONS ● W2.2 ELEVATIONS ● W2.3 ELEVATIONS ● W2.4 ELEVATIONS ● W3.1 ROOF PLAN ● W4.0 SECTIONS ● W4.1 SECTIONS ● W5.0 DETAILS ● W5.1 DETAILS ● W5.2 DETAILS ● W5.3 DETAILS ● W5.4 DETAILS ● W5.5 DETAILS ● SIP PANEL SHOP DRAWINGS W YELM AVENUE / SR 510 KILLION ROAD SE (ACCESS ROAD) ACCESSIBLE PATH OF TRAVEL FIREFIGHTER WALKWAY ACCESS ROUTE PROPERTY LINE FIRE EXTINGUISHER, SEE FUEL TANK/GASF A. SIGNS REQUIRE A SEPARATE PERMIT. B. DUMPSTERS AND MECHANICAL EQUIPMENT WILL BE SCREENED FROM THE PUBLIC. C. NOT USED. D. PARKING WILL BE PAVED. E. PARKING WILL BE WITHIN 600' OF BUILDING. F. THERE SHALL BE NO OBSTRUCTION OF SITE SIGNAGE BY LANDSCAPE PLANT MATERIAL, AND SUCH MUST BE RELOCATED/CORRECTED BEFORE THE FIELD INSPECTION WILL ACCEPT/PASS THE SIGN IN THE FIELD OR ISSUE A CERTIFICATE OF OCCUPANCY FOR A PROJECT. G. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. H. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. I. ALL SITE IMPROVEMENTS, INCLUDING LANDSCAPE AND SITE CLEANUP, MUST BE COMPLETED PRIOR TO CERTIFICATE OF OCCUPANCY FOR ANY BUILDING WITHIN A PHASE. J. THE FIRE DEPT. DOUBLE CHECK ASSEMBLY SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR. K. ALL EXTERNAL LIGHTING SHALL BE LOCATED AND DESIGNED TO PREVENT RAYS FROM BEING DIRECTED OFF OF THE PROPERTY UPON WHICH THE LIGHTING IS LOCATED. PROJECT NAME: PROJECT ADDRESS: PROJECT DESCRIPTION: CIRCLE K CONVENIENCE STORE & FUEL PUMPS NWC YELM AVENUE & KILLION ROAD, YELM WA 98597 PROPOSAL FOR A NEW CONVENIENCE STORE WITH ASSOCIATED FUEL SALES CONSISTING OF A 5,200 S.F.CONVENIENCE STORE AND A 4,608 S.F.FUEL CANOPY WITH [7] FUEL PUMPS. THE CONVENIENCE STORE WILL SELL BEER AND WINE FOR OFFSITE CONSUMPTION. THE FACILITY WILL OPERATE 24 HOURS. PARCEL/SITE AREA:2.35 AC / ±102,366 S.F. EXISTING ZONING:C 1 COMMERCIAL PARCEL NUMBER:21724130100 MAX. BUILD. HEIGHT:23' 0" PROVIDED (60' ALLOWED) MAX. FUEL CANOPY HEIGHT:18' 6" PROVIDED (60' ALLOWED) PARKING: REQUIRED:5200 SF/250 = 21 PARKING STALLS PROVIDED: STANDARD PARKING: ACCESSIBLE PARKING: EVCS STALL: TOTAL PARKING PROVIDED: 20 SP 1 SP 0 SP 21 SP BICYCLE:2 BICYCLE RACK (4 SPACES) PROVIDED S27 S3 S6 S20 S7 S17 S19 S6 S4 S5 S27 S2 S23 S21 S11 S15 S27 S11 S16 S10 S4 SLEEVE DRIVE S27 S2 S28 S10 S3 S11 S11 S22 S13 S27 S9 CIRCLE K 5,200 S.F. F.F.F. = 353.50' S1 S24 S11S14S26 S2 S24 SLEEVE DRIVE E STOP E STOP FUEL CANOPY V 7 4,608 S.F. S24 UNDER COUNTER S2 S2 S18 S10 8K EO 20K REGULAR 12K DIESEL 12K SUL 20 ' 0 " 4 6 ' 0 " 113' 0" 8K CK CHOICE S32 S33 (SEE KEYNOTE A 30 ON SHEET A1.2) S30 S3 S5S5 S6 S10 S18 S18 S18 S18 S22 S30 S30 S31 24 ' 0 " 192' 0" S T O P R A D I U S (T Y P.) R =1 0 0' E M E R G E N C Y S T O P R A D I U S ( T Y P . ) R = 1 0 0 ' E M E R G E N C Y S8 S8 S25 S25 S30 95' 5 5/8" 21 S29 FFF F F F F S1. BUILDING AREA S2. PAVING AT DRIVEWAY AND PARKING AREA, SEE CIVIL PLANS. S3. LANDSCAPE AREA, SEE LANDSCAPE PLANS S4. PROPOSED PYLON/MONUMENT SIGN, UNDER SEPARATE PERMIT. SEE ELECTRICAL PLANS FOR POWER REQUIREMENTS S5. LANDSCAPE PLANTER AREA, SEE LANDSCAPE PLANS. S6. CONCRETE WALK, SEE CIVIL PLANS AND SITE DETAILS SHEET SD1.2 S7. ELECTRICAL TRANSFORMER PROPOSED LOCATION. POWER COMPANY TO DETERMINE FINAL LOCATION. S8. PROPOSED DIRECTIONAL SIGN, UNDER SEPARATE PERMIT. SEE ELECTRICAL PLANS FOR POWER REQUIREMENTS S9. TRASH ENCLOSURE PER CITY STANDARD DETAILS, AND CIRCLE K APPROVAL. SEE SITE DETAIL 9/SD1.3 S10. CONC. CURB AND GUTTER, SEE CIVIL PLANS S11. CONCRETE PAVING, SEE CIVIL PLANS S12. PARKING LIGHT POLE FIXTURE, SEE STRUCT. & ELECT. PLANS. S13. ACCESSIBLE RAMP, SEE CIVIL PLANS AND DETAIL 6/SD1.2 S14. ACCESSIBLE PARKING PER CITY REQUIREMENTS, SEE DETAIL 12/SD1.2 S15. VENT PIPES LOCATION, SEE FUEL PLAN. S16. FUEL CANOPY AREA, SEE FUEL SHEETS FOR MORE INFORMATION S17. BICYCLE RACK SEE DETAIL 14/SD1.2 S18. SCREEN WALL. SEE LANDSCAPE PLANS AND DETAILS. S19. CO2 WITH STORAGE CABINET SEE DETAILS 3/A1.3 S20. BUILDING SERVICE DISCONNECT, SEE ELECTRICAL S21. PROVIDE AND INSTALL FUEL STORAGE TANKS PER FUEL/GAS PLANS S22. 4" BOLLARD, SPACED EVERY 6', SEE DETAIL 1/SD1.2 S23. AIR/WATER MACHINE,PROVIDED BY CIRCLE K VENDOR, SEE CIVIL AND ELECT. PLANS S24. EMERGENCY SHUT OFF SWITCH, SEE FUEL PLAN S25. PROPOSE BIORETENTION POND, SEE CIVIL PLANS AND DETAILS. S26. OUTDOOR PAINTED STRIPES FOR NO PARKING AREA, SEE DETAIL 12/SD1.2 S27. PROPERTY LINE S28. 6" DIA FUEL CANOPY BOLLARDS WITH GRAY COVERS S29. GREASE INTERCEPTOR. S30. BUILDING SETBACK S31. EXISTING FIRE HYDRANT. S32. GREASE TRAP, SEE CIVIL AND PLUMBING DWGS. S33. EXTERIOR ROOF ACCESS LADDER REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC SD1.1 PROJECT NUMBER: 24212 SITE PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 SITE LEGEND PROJECT DATA GENERAL SITE NOTES KEY NOTES 1" = 20' 0" 1SITE PLAN 4" BOLLARD COVERED WITH "RED" POST GAURD PLASTIC SLEEVE 4" SCH. 40 STEEL PIPE CONCRETE FILLED BOLLARD CAULK SEAL BOLLARD COVER BASE, TYP. FOAM WRAP, TYP. FILL POST WITH CONCRETE 2500 PSI P.C. CONCRETE MINIMUM, TYP. 1' 0" 4" 2' 8 " 3' 6 " . 6' 6 " . 3" M I N . FRONT ENTRANCE 4" DIA. BOLLARD TYP. SEE DET. 1/SD1.2 NOTE: EXPANSION JOINTS PER INDUSTRY STANDARD C STORE NTI 10 ' 1 " 1' 6 " 10 ' 4 " 6' 0" TYP. BOLLARD COVERED WITH "RED POST GAURD PLASTIC SLEEVE" 4" SCH. 40 STEEL PIPE CONCRETE FILLED BOLLARD CAULK SEAL BOLLARD COVER BASE, TYP. FOAM WRAP, TYP. FILL POST WITH CONCRETE 2500 PSI P.C. CONCRETE MINIMUM, TYP. 1' 0" 4" 2' 8 " 3' 6 " . MINIMUM FINE $250 VAN ACCESSIBLE RESERVED PARKING 4" HANDICAP PLATE OR PERMIT ONLY 4" 4" 5' 0 " . RUST PROOF 2" ROUND GALVANOZED POST INSIDE THE STEEL BOLLARD AND ENCASED IN CONCRETE 2' 6 " 6" 6 " 1 ' 6 " 2" 2" 2" 2" 2" 2" 2" GREEN LETTERING 4" x 4" BLUE ACCESSIBLE SIGN WHITE REFLECTIVE BACKGROUND TYPICAL 1" GREEN LETTERING 11 GA. GALV. SHEET METAL BACKING PLATE PAINTED BOTH SIDES 2" GREEN LETTERING 3" M I N . NOTES: SIGNS SHALL BE MOUNTED TO POST WITH GALVANIZED OR CADMIUM PLATE 5/16" DIAMETER STEEL BOLTS, NUTS AND WASHERS. THE CONTRACTOR SHALL SUPPLY AND INSTALL 5/16" NYLON WASHERS BETWEEN BOLT HEADS AND SIGN FACE TO PROTECT FINISH. 1' 0" 6' 0" 5' 0" 6' 0" 6' 0 " SLOPE 1:12 MAX. SLOPE 1:12 MAX. S L O P E 1: 1 2 M A X . CONCRETE WALK, SEE PLAN TOOLED JOINTS AT 2" O.C. EDGE OF WALK TRUNCATED DOME CONCRETE PAVERS DETECTABLE SURFACE 'RED' OR 'YELLOW' COLOR NOTE: ALL A.D.A. REQUIREMENTS TO BE INSTALLED PER APPROVED ARCHITECT'S PLANS TRUNCATED DOME CONCRETE PAVERS DETECTABLE SURFACE 'RED' COLOR TOOLED JOINTS AT 2" O.C. LANDSCAPE AREA, SEE SITE PLAN LANDING LANDSCAPE AREA, SEE SITE PLAN CONCRETE WALK, SEE PLAN 5' 0"FLUSH W/ASPHAL T 6 0 " M I N . 2 ' 0 " S L O P E 1 :1 2 M A X . 6 ' 0 " M A X . SD1.2 10 5' 0" 5' 0 " 5' 0" 4" WIDE YELLOW PAINT STRIPING (TYP.) 4" WIDE YELLOW PAINT STRIPING (TYP.) THIS SIDE TOWARD DRIVE AISLE * 4" WIDE PAINT STRIPING (PAINTED WHITE) * 22' 0" 11' 0" 5' 0" 6' 0" BUILDING LINE ACCESSIBLE PARKING SIGN WITH BOLLARDS, SEE DETAIL 5/SD1.2 0" CURB DIAGONAL 4" PAINT STRIPING AT 24" O.C. (PAINTED WHITE) 8' ACCESS AISLE REQ'D 2.ACCESSIBLE SPACES MUST BE PROMINENTLY OUTLINED IN COLORS OR LATERALS CONTRASTING FROM REGULAR PARKING SPACES 3.INTERNATIONAL ACCESSIBLE SYMBOL REQ'D BLUE & YELLOW SYMBOL PREFERRED SYMBOL CAN BE DISPLAYED WITHOUT BLUE BACKGROUND 4.ACCESSIBLE SIGN REQ'D MUST NEVER BE OBSCURED SD1.2 15 *2% MAX. SLOPE EACH WAY EQ EQ 60 " M I N . 2' 4 " 1' 8" 2' 4 " 2' 2" 2" DIA. STEEL PIPE BIKE RACK, PRIMED & PAINTED 2 1/2" CONT. STEEL PLATE, PRIMED & PAINTED, WELD TO STEEL PIPE. 4" CONC. PAVING ON 4" A.B.C. 1/2" EXPANSION BOLT @ 26" O.C. 2 1/2" CONT. STEEL PLATE, PRIMED & PAINTED, WELD TO STEEL PIPE. 2" DIA. STEEL PIPE BIKE RACK, PRIMED & PAINTED 2' 2" 27 " M A X I M U M 6" 6" COMPACTED EARTH #4 REINFORCING BAR X 10" @ 4" O.C. ASPHALT PAVING C.I.P. CONC. CURB 3/4" R. TYP. LANDSCAPE PLANTER AREA . 1"4"1" 4" 8" 2" 6 " 8" SLOPE 1/4"/FT COMPACTED EARTH #4 REINFORCING BAR CONTINUOUS PLANTABLE FILL C.I.P. CONCRETE WALK OVER 4" A.B.C. 3/4" R. SLOPE 1/4"/FT COMPACTED EARTH #4 REINFORCING BAR CONTINUOUS BATTER 3:12 4" CONCRETE WALK OVER 4" A.B.C. 3/4" R. ASPHALT PAVING 6" 1' 0 " 4" 6" SLOPE 1" PER FOOT 1' 0 " 6" 4" 6" 1" COMPACTED EARTH #4 REINFORCING BAR CONTINUOUS ASPHALT PAVING 4" CONC. WALK OVER 4" A.B.C. 3/4" R. TRUNCATED DOME CONCRETE PAVERS DETECTABLE SURFACE TOOLED JOINTS @ 2" O.C. 1/2" CONTINUOUS EXPANSION JOINT FILLER CONCRETE SLAB, SEE STRUCT. 1/2" W x 1/2" D GROOVE W/ SEALANT AT SLAB FACE OF WALL REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC SD1.2 PROJECT NUMBER: 24212 SITE DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1" = 1' 0" 1GUARD POST 1/8" = 1' 0" 4TYP.FRONT CONCRETE + BOLLARD 1" = 1' 0" 5HANDICAP ACCESSIBLE SIGN 3/16" = 1' 0" 6ACCESSIBLE RAMPS 1/2" = 1' 0" 7NOT USED 1/2" = 1' 0" 15ACCESSIBLE PARKING SYMBOL 1/8" = 1' 0" 12ACCESSIBLE PARKING STALL 3/4" = 1' 0" 14BIKE RACK DETAIL (TYPICAL OF 2) 1" = 1' 0" 2TEMPORARY EXTRUDED CURB 1" = 1' 0" 8EDGE OF WALK AT PLANTER 1" = 1' 0" 9SIDEWALK TURNDOWN 1" = 1' 0" 10WALK AT RAMP 3" = 1' 0" 13TYPICAL SLAB AT GRADE 6' 6" T.O. ENCLOSURE FRAMING PIPE BOLLARD REF PLAN 6" STL. DIA. GALVANIZED PIPE POST FILLED WITH CONCRETE NICHIHA FIBER CEMENT PANELS 24 GA REVERSE R PANEL SHEATHING TREATED 2X4 HORIZONTAL SUPPORTS WOOD TO STEEL FENCE LINE / END ADAPTER 3" NOM. O.D. GALVANIZED STEEL POST 6 5/8" O.D. ROUND SCHEDULE 40 PIPE WITH MIN. CLEARANCE OF 3 1/2" AROUND PIPE GATE CLOSE POSITION GA T E O P E N P O S I T I O N ULTIMATE CLIP 20 GA. FLASHING, GC SUPPLIED COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA FIRESTONE MANSARD BROWN SR 1/2" APA RATED PLYWOOD TREATED 2X4 BLOCKING TOP OF COLUMN AND WOOD TO STEEL FENCE LINE / END ADAPTER BEYOND 3" NOM. O.D. GALVANIZED STEEL POST NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6115 TOTALLY TAN 3" SEALANT _______ SD1.3 7 _______ SD1.3 2 _______ SD1.3 8 _______ SD1.3 5 CONTROL JOINT, TYP. SL O P E 1/ 4 " / F T SD1.3 1 6" 26' 0" 6" 12' 6" 12' 6" EQ EQ EQ EQ EQ EQ 6" 1 3 ' 0 " 1' 0 " 1 ' 0 " 25' 0" 1' 0"10' 6"10' 6"1' 0" 11"4 1/2"10' 0"4"1' 9"4"10' 0"4 1/2"11" 3' 8" 3' 0" 3' 0" 3' 4" 3' 4" 3' 0" 3' 0" 3' 8" 5' 6 " CL R 3 1 / 2 " 4" EQ E Q 4' 0 " 4" 3 1 / 2 " (QTY. 7) 6"DIA x4' 0" TALL STEEL PIPE BOLLARD GROUT, GROUT AND SET 2' IN CONCRETE FOOTING. MOUNTED INSIDE ENCLOSURE 3" NOM O.D. GALVANIZED STEEL POST WITH WOOD TO STEEL ADAPTER (TYP) PROVIDE PVC SLEEVES IN CONCRETE TYP. PEDESTRIAN ACCESS GATE 6 5/8" O.D. ROUND SCHEDULE 40 PIPE WITH MIN. CLEARANCE OF 3 1/2" AROUND PIPE, TYP. 6" CONCRETE, DESIGN STRENGTH 3,000 PSI WITH NO. 4 REBARS AT 12" O.C. BOTH WAYS. RE F . C I V I L 6" 6 ' 0 " 20 GA. PRE FINISHED FLASHING COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6115 TOTALLY TAN 11 1 / 8 " 6" DIA. GALVANIZED PIPE POST COLOR TO MATCH #SW 6090 JAVA NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6115 TOTALLY TAN PROVIDE 3/4" PVC SLEEVES IN CONCRETE. TYP MUELLER URETHANE GATES INTERNALLY COLOR TO MATCH #SW 6090 JAVA 20 GA. PRE FINISHED FLASHING COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA 6" DIA. GALVANIZED BOLLARD 6' 0 " 20 GA. PRE FINISHED FLASHING COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA S.S. HANDLE PROVIDE 3/4" PVC SLEEVES IN CONCRETE. TYP PROVIDE 3/4" PVC SLEEVES IN CONCRETE. TYP 5/8" X 24" S.S. CANE BOLT AT EACH GATE. (ALTERNATE SIDES OF PANEL) MUELLER URETHANE GATES INTERNALLY COLOR TO MATCH #SW 6090 JAVA 6" DIA. GALVANIZED BOLLARD 20 GA. PRE FINISHED FLASHING COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA 6" DIA. GALVANIZED PIPE POST COLOR TO MATCH #SW 6090 JAVA NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6115 TOTALLY TAN 20 GA. PRE FINISHED FLASHING COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA TOP OF STEEL PIPE CONCRETE FILL TO BE STRIKED OFF FLAT 6 5/8" O.D. ROUND SCHEDULE 40 PIPE WITH MIN. CLEARANCE OF 3 1/2" AROUND PIPE, TYP. LOWER ALUM. BRACKET POST AND CONCRETE FOOTING UPPER ALUM. BRACKET SEE STRU. 4' 1 1 1 / 2 " 1 ' 4 " S E E S T R U . MI N 3" 20 GA. PRE FINISHED FLASHING COLOR TO MATCH SHERWIN WILLIAMS #SW 6090 JAVA NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6115 TOTALLY TAN 3" NOM. O.D. GALVANIZED STEEL POST TREATED 2X4 HORIZONTAL SUPPORTS (TYP) 22 GA. REVERSE R PANEL SHEATHING REF ARCH FOR SLAB THICKNESS AND REINFORCING #4 T&B WITH MATCHING CORNER BARS T.O. ENCLOSURE FRAMING 6' 6" 17 5 / 8 " 1 7 5 / 8 " 1 7 5 / 8 " 1 7 5 / 8 " 6 " SEE STRU. SD1.3 4 SE E S T R U . CL R 3" REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC SD1.3 PROJECT NUMBER: 24212 SITE DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1 1/2" = 1' 0" 1ENCLOSURE GATE HINGE 3" = 1' 0" 4DETAIL COPING 1/4" = 1' 0" 9TRASH ENCLOSURE (PLAN) 1/2" = 1' 0" 7TRASH ENCLOSURE REAR ELEVATION 1/2" = 1' 0" 2TRASH ENCLOSURE SIDE ELEVATION 1/2" = 1' 0" 8TRASH ENCLOSURE FRONT ELEVATION 1/2" = 1' 0" 5TRASH ENCLOSURE SIDE ELEVATION 1/2" = 1' 0" 6GATE BOLLARD DETAIL 1/2" = 1' 0" 3TRASH ENCLOSURE WALL SECTION A A B B 1 1 2 2 TURNING RADIUS ø 5' 0" TURNING RADIUS ø 5' 0" (TO FACE OF SIP) 113' 0" (TO FACE OF SIP) 46 ' 0 " (TO FACE OF SIP) 113' 0" REMOTE DISTANCE = 96' 10" TO EXIT #1 REMOTE DISTANCE = 36' 0" TO EXIT #2 = 116' 0" TO EXIT #1 = 84' 1" TO EXIT #3 REMOTE DISTANCE = 51' 2" REMOTE DISTANCE = 49' 9" REMOTE DISTANCE = 74' 0" TO EXIT #4 ADA 3' 0" ADA 3' 0" ADA 3' 0" ADA 3' 0" DIAGONAL DISTANCE = 120' 8" 1/2 DIAGONAL DISTANCE = 60' 4" ADA 3' 0" ADA 3' 0" AD A 3' 0 " AD A 3' 0 " AD A 3' 0 " REMOTE DISTANCE = 47' 8" TO EXIT #4 REMOTE DISTANCE = 58' 2" TO EXIT #1 CO M M O N P A T H O F T R A V E L D I S T A N C E = 4 2 ' 0 " COMMON PATH OF TRAVEL DISTANCE = 68' 8" SIGN 1 SIGN 2 SIGN 3 SIGN 3 SIGN 3 SIGN 4 SIGN 5 TURNING RADIUS ø 5' 0" WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 HALLWAY 111 PREP AREA 110 CASHIER 108 SALES FLOOR 107 WALK IN COOLER 104 BACK ROOM 109 AD A 3' 0 " (T O F A C E O F S I P ) 46 ' 0 " ADA 3' 0" EXIT #2 SIGN 6 SIGN 2 BC S BC S EXIT #3 EXIT #1 SIGN 2 SIGN 3 SIGN 6 EXIT #4 TURNING RADIUS ø 5' 0" CO2 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L W H ATM 4R V Z C 3 0 T 2 4R V Z C 3 0 4R V Z C 3 0 4R V Z C 3 0 T 2 CLEARANCE 3' 0" TURNING RADIUS ø 5' 0" EXTERIOR ROOF ACCESS LADDER SIGN 1 AD A 3' 0 " AD A 3' 0 " TURNING RADIUS ø 5' 0" ADA 3' 0" AD A 3' 0 " AD A 3' 0 " AD A 3' 0 " ADA 3' 0" STRAIGHT LINE DISTANCE = 82' 3" AD A 3' 0 " ADA 3' 0" AD A 3' 0 " ADA 3' 0" ADA 3' 0" MEN'S RESTROOM 102 WOMEN'S RESTROOM 101 OCCUPANCY: M 63 OCCUPANTS AD A 3' 0 " = ROUTE FROM THE REMOTEST ROOM OR SPACE TO NEAREST EXIT = STRAIGHT LINE DISTANCE BETWEEN EXITS = DIAGONAL DISTANCE OF THE BUILDING OR AREA 1. MEANS OF EGRESS SHALL BE ILLUMINATED WITH AT LEAST ONE FOOT CANDLE AT THE FLOOR LEVEL (WALKING SURFACE), REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION 2. CASHIER COUNTER HEIGHTS ARE 34", REFER TO INTERIOR ELEVATIONS ON SHEET A3.1. PARALLEL APPROACH IS PROVIDED AND COMPLY WITH ANSI 117.1 AND 2010 ADA STANDARDS SECTION 904.4.1 EXCEPTION = MOST REMOTE POINT WITHIN THIS AREA = ILLUMINATED EXIT SIGN = EMERGENCY LIGHT GENERAL NOTES LEGEND EXIT REQUIREMENTS TRAVEL DISTANCE COMMON PATH OF TRAVEL ALLOWABLE TRAVEL DISTANCE 200 FT PER WBC 2021 TABLE 1017.2 WITHOUT SPRINKLER COMMON PATH PER WBC 2021 TABLE 1006.2.1 OF TRAVEL DISTANCE WITHOUT SPRINKLER 75 FT ACTUAL COMMON PATH OF TRAVEL DISTANCE 68' 8" FT. MINIMUM NO. OF EXITS ARRANGEMENT MEANS OF EGRESS REQUIRED 2 PROVIDED 4 REQUIRED DISTANCE BETWEEN EXIT DOORS WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS. INTERLOCKING OR SCISSOR STAIRS SHALL BE COUNTED AS ONE EXIT STAIRWAY PER WBC 2021 1007.1.1 EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN ONE THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIMENSION OF THE AREA SERVED. ACTUAL STRAIGHT LINE DISTANCE BETWEEN EXITS EXIT #1 TO #2 = 82' 3" ACTUAL STRAIGHT LINE ACROSS PUBLIC AREA: DIAGONAL AT PUBLIC AREA = 120' 8" 1/2 DIAGONAL = 60' 4" CONCLUSION = = 82' 3" IS GREATER THAN 60' 4" (MEETS CODE FOR NON SPRINKLERED BUILDING) (NUMBER AND ARRANGEMENT OF EXITS) INTERNATIONAL SYMBOL OF ACCESSIBILITY ACCESSIBILITY SIGNS "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" LETTER MIN. 1" HIGH. SIGN MOUNTED ABOVE DOOR. TACTILE EXIT SIGN SHALL COMPLY ADA STANDARD SECTION 703.3 AND ANSI A117.1 2009 MEN RESTROOM WOMEN RESTROOM SIGN 1 SIGN 2 SIGN 3 SIGN 4 SIGN 5 NOTES: INSPECTOR MAY REQUIRE ADDITIONAL EXIT SIGNS AT THE TIME OF FINAL INSPECTION. SIGNAGE COMPANY AND GC TO BOTH MAKE SURE ALL UTILITY LINES HAVE BEEN LOCATED PRIOR TO DIGGING FOOTING. GC RESPONSIBLE TO CALL AND HAVE UTILITIES LOCATED. SIGNAGE COMPANY RESPONSIBLE TO CONFIRM THIS HAS BEEN DONE. EMPLOYEES ONLYSIGN 6 1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES. 2. THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX. GROSS SLOPE 2%. 3. WALKING SURFACE SLOPING GREATER THAN 2% SHALL BE SLIP RESISTANT. 4. PROVIDE A 60"x60" MIN. LANDING ON STRIKE SIDE OF DOOR W/ 44" MIN. WIDTH IN DIRECTION OF TRAVEL. 5. WALKS SHALL EXTEND 18" TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK. 6. THE SLOPE OF RAMPS SHALL NOT EXCEED 1' 0" IN 15' 0" U.N.O. 7. RAMPS SHALL HAVE A NON SLIP SURFACE. 8. RAMPS SHALL BE 48" WIDE MIN. 9. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3 FT. WIDE BY NOT LESS THAN 6" 8" HIGH CAPABLE OF OPENING 90° AND MOUNTED SO THAT THE CLEAR WIDTH OF THE EXIT WAY IS 32" MIN. 10.THRESHOLD TO BE A MAX. 1/2" ABOVE ADJACENT FINISH FLOOR. 11.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. 12.THE BOTTOM OF ALL DOORS WITHIN 10" OF FINISHED FLOOR EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 13.PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. (34" TO 48" A.F.F.) 14.EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT, FLUSH OR SURFACE BOLTS SHALL BE AUTOMATIC TYPE. LOCKABLE DOORS SHALL BE PROVIDED WITH A SIGN STATING " THESE DOORS TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" IN MIN. 1" HIGH LETTERS. 15.EXIT SIGNS WHERE NOTED OR REQUIRED SHALL BE WORDED "EXIT" IN AND LETTERS HAVING THE PRINCIPAL STROKE OF NOT LESS THAN 3/4" WIDE AND 6" HIGH AND SHALL CONFORM TO ALL APPLICABLE CODES. ACCESSIBILITY NOTES 16.PROVIDE ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING AT ALL EXIT CORRIDORS AS REQUIRED BY CODE. EMERGENCY LIGHTING SHALL PROVIDE ILLUMINATION OF ONE FOOT CANDLE AT FLOOR LEVEL. 17.POST INTERNATIONAL SYMBOL OF ACCESSIBILITY ON OR ADJACENT TO ALL ACCESSIBLE BUILDING ENTRANCES. LOCATION AS INDICATED BY OWNER. 18.DESIGNATED SEATING SHALL BE ACCESSIBLE IN ACCORDANCE WITH SECTION 902 OF ANSI 117.1 2009. 19.WORK SURFACES AT SYSTEMS AND FURNITURE FURNISHED AND INSTALLED BY CIRCLE K STORES INC. SHALL BE IN COMPLIANCE WITH SECTION 902 OF ANSI 117.1 2009. 20.SALES AND SERVICE COUNTERS: CUSTOMER SERVICE COUNTERS SHALL BE IN COMPLIANCE WITH SECTION 904.3.1 AND 904.3.2 OF ANSI 117.1 2009. AND 2010 ADA STANDARD SECTION 904.4 21.CHECK OUT COUNTERS SHALL BE IN COMPLIANCE WITH SECTION 904.4 OF ANSI 117.1 2009. 22.FOOD SERVICE COUNTERS AND CONDIMENT STATIONS SHALL BE IN COMPLIANCE WITH SECTION 904.4 OF ANSI 117.1 2009. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.0 PROJECT NUMBER: 24212 EGRESS/ ACCESSIBILITY FLOOR PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 NOTE: • PER ICC ANSI 117.1, 308. WHERE FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48 INCHES MAXIMUM AND THE LOW FORWARD REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FLOOR. TYPICAL. 3/16" = 1' 0" 1EGRESS / ACCESSIBILITY FLOOR PLAN 1' 3" (HOLD) CENTERLINE OF FIXTURE F. O . F . MIN. . CENTERLINE OF FIXTURE F. O . F . 1' 4" 1' 6" (HOLD)6" MAX. MA X . 1' 0 " 5' 0" 4' 6 " M I N . . 48" X 60" SPACE IN FRONT OF WATER CLOSET 8" MAX. .12" MAX .28" MINIMUM TO EDGE OF WATER CLOSET F. O . F . CENTERLINE OF FIXTURE F. O . F . 5' 0" .28" MIN. TO EDGE OF WATER CLOSET 6" MAX.CENTERLINE OF FIXTURE MIN. . . . 48 " M I N . CL E A R .24 " .32" MINIMUM CLEARANCE 60" MINIM U M DIA M E T E R C L E A R A N C E 1' 4" 1' 6" (HOLD)1' 3" (HOLD) SINGLE ACCOMMODATION ROOMS NEW CONSTRUCTION MINIMUM 1' 6" NOTE: SIDE TRANSFER MAY VARY DEPENDING ON STATE 15 0 0 56 " M I N . 1525 60" MIN. (A) ADULT WALL HUNG WATER CLOSET 16" 18" 14 2 0 59 " M I N . 1525 60" MIN. 16" 18" 15 0 6" M I N . 150 6" MIN. 30 5 12 " M I N . PARTITION (A) ELEVATION (B) PLAN (B) ADULT FLOOR MOUNTED WATER CLOSET AND CHILDREN'S WATER CLOSET TOE CLEARANCE 150 6" MIN. CLCL WHEELCHAIR ACCESSIBLE COMPARTMENT .6 0 " M I N I M U M D I A M E T E R C L E A R A N C E 1' 6 " MAX. 1' 0" 3' 6" MIN. 3' 3" 3' 6" . 11" 17" TO TOP OF TOILET SEAT 7" 9" 1 1 / 2 " 14 " M I N . 19 " M A X . 2' 9 " . 4' 6" MIN. . 39 " 4 1 " ROLL PAPER HOLDER WITHOUT STOPS MIN. 1' 0"MIN. 3' 0" MIN. 2' 0" 2' 9 " . . 1 1/2" MAX 1 1/4" 1 1/2" SOAP TRASH PRODUCT DISPENSER SEAT COVER DISPENSER 2' 0 " M I N . 3' 4 " M A X . WATER CLOSET AND ACCESSORIES: 1. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17" AND A MAXIMUM OF 19" MEASURED TO THE TOP OF A MAXIMUM 2" HIGH TOILET SEAT, EXCEPT THAT 3" SEATS SHALL BE PERMITTED ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS THAN 15" HIGH. 2. THE CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS. AUTOMATIC SPRING TO LIFTED POSITION SEATS ARE NOT ALLOWED. 3. THE FORCE REQUIRED TO ACTIVATE WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND FAUCET AND OPERATING MECHANISM CONTROLS, SHALL BE NO GREATER THAN 5 LBS. ELECTRONIC OR AUTOMATIC FLUSHING CONTROLS ARE ACCEPTABLE AND PREFERABLE. 4. WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, DISPENSERS, OR OTHER EQUIPMENT AND CONTROLS ARE PROVIDED, PROVIDE AT LEAST ONE OF EACH TYPE SHALL BE ON AN ACCESSIBLE ROUTE, WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM THE FINISHED FLOOR. 5. THE TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL WITHIN 7 9" OF THE FRONT EDGE OF THE TOILET SEAT, MOUNTED BELOW THE GRAB BAR AT A MINIMUM HEIGHT OF 15", AND 48" MAXIMUM AFF. DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED. GRAB BARS: 1. THE REAR GRAB BARS SHALL BE 36" LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12" MINIMUM ON ONE SIDE AND 24" MINIMUM ON THE OTHER SIDE. THE REAR GRAB BAR SHALL BE SECURELY ATTACHED AND CENTERED 33" ABOVE AND PARALLEL TO THE FLOOR, EXCEPT THAT WHERE A TANK TYPE TOILET IS USED, WHICH OBSTRUCTS PLACEMENT AT 33", THE BAR MAY BE AS HIGH AS 36", WITH A 1 1/2" MINIMUM BETWEEN THE BAR AND TOP OF THE TANK. 2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1 1/4" TO 2", OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL BE 1 1/2". 3. THE STRUCTURAL STRENGTH OF THE GRAB BARS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS: A. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF A 250 LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT. B. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250 LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESS SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. C. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A 250 LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD. D. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250 LB LOAD, SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING STRUCTURE. E. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 4. THE GRAB BARS AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". 1. ACCESSIBILITY STANDARDS MAY VARY SLIGHTLY FROM THOSE SHOWN HERE ACCORDING TO THE REFERENCED STANDARDS OF THE APPLICABLE CODES, (ANSI A117.1 (I.B.C.)), THE YEAR OF THE CODE ADOPTED AT THE TIME OF THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY, THE LOCAL JURISDICTION REQUIREMENTS, THE CODE ITSELF AS STATED (TITLE 24 OF THE C.B.C., B.O.C.A. OR THE I.B.C.), THE REQUIREMENTS OF AN ADOPTED STATE LAW OR A PRECEDENT PREVIOUSLY SET FOR COMPLIANCE BY THE JUSTICE DEPARTMENT (A.D.A.). 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INFORM THE ARCHITECT AND/OR THE CIVIL ENGINEER OF ANY DISCREPANCIES, SUBTLE OR OTHERWISE, FROM WHAT IS SHOWN HERE AND THE APPLICABLE CODE/LAW/ORDINANCE. 3. THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY AS AID FOR BUILDING AND CONSTRUCTION. GENERAL NOTES 16" 18" CL HAND DRYER DOOR NOTES: 1. WHEN INSTALLED, DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THE DOOR OPEN 90 DEGREES. 2. FOR HINGED DOORS, THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 3. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 4. THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60 INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF THE DOOR SWING OF 48 INCHES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION. WHERE THE PLANE OF THE DOORWAY IS OFFSET OR LOCATED IN AN ALCOVE A DISTANCE MORE THAN 8 INCHES MEASURED FROM THE PLANE OF THE DOORWAY TO THE FACE OF THE WALL, THE DOOR SHALL BE PROVIDED WITH 60 INCHES MANEUVERING CLEARANCE FOR FRONT APPROACH. 5. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS. WHERE THE PLANE OF THE DOORWAY IS OFFSET 8 OR MORE INCHES FROM ANY OBSTRUCTION WITHIN 18 INCHES MEASURED LATERALLY ON THE LATCH SIDE, THE DOOR SHALL BE PROVIDED WITH MANEUVERING CLEARANCE FOR FRONT APPROACH. 6. PROVIDE CLEAR SPACE OF 12 INCHES PAST STRIKE EDGE OF THE DOOR ON THE OPPOSITE SIDE TO WHICH THE DOOR SWINGS IF THE DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER. 7. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF THE DOORWAY. 8. THE BOTTOM OF ALL DOORS WITHIN 10" ABOVE FINISH FLOOR EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. THRESHOLD 2 1 1/ 4 " M A X . AT 1 : 2 S LO P E 1/ 2 " M A X . FLOOR FINISH TO BE FLUSH OR MEET SLOPE STANDARDS FOR TRANSITIONS AS SHOWN ON BOTH SIDES FINISH FLOOR EVEN THRESHOLD . COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD DOOR HARDWARE NOTES: 1. DOOR HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. MANUALLY OPERATED BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 2. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 3. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44INCHES ABOVE THE FLOOR. 4. WHEN AN AUTOMATIC OR POWER ASSISTED DOOR OPERATOR IS UTILIZED TO OPERATE A PAIR OF DOORS, AT LEAST ONE OF THE DOORS SHALL BE CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. AUTOMATIC DOORS SHALL COMPLY WITH BHMA A156.10 OR BHMA A156.19. EFFORT TO OPERATE DOOR 1. THE MAXIMUM FORCE REQUIRED TO PUSH OR PULL OPEN A DOOR SHALL COMPLY WITH THE FOLLOWING: A. PUSH OR PULL FORCE FOR A HINGED DOOR SHALL BE MEASURED PERPENDICULAR TO THE DOOR FACE AT THE DOOR OPENING HARDWARE OR 30 INCHES FROM THE HINGED SIDE, WHICHEVER IS FARTHER FROM THE HINGE. B. PUSH OR PULL FORCE FOR A SLIDING DOOR OR FOLDING DOOR SHALL BE MEASURED PARALLEL TO THE DOOR AT THE DOOR PULL OR LATCH. C. DOORS AND GATE OPENING FORCE PER 2010 ADA SECTION 404.2.9 FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: 1) INTERIOR HINGED DOORS AND GATES ; 5 POUNDS (22.2N) MAXIMUM. 2) SLIDING OR FOLDING DOORS : 5 POUNDS (22.2N) MAXIMUM. D. CLOSING SPEED DOOR AND GATE CLOSING SHALL COMPLY WITH SECTION 404.2.8 AS FOLLOWS: 1) DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. 2) DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES,THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM. . 3' 0" MIN. . 42 " M I N . 60 " M I N . 54" MIN. PULL SIDE PUSH SIDE *NOTE: 48" MINIMUM IF DOOR HAS BOTH A LATCH AND A CLOSER 4' 0 " M I N . . MIN. 1' 6"32" CLEAR .12" MIN. AS REQUIRED SPACE IS NECESSARY TO ALLOW BACKING AND TURNING SPACE FOR A WHEELCHAIR TO CLEAR ANY DOOR IN ANY POSITION MIN. 1' 0" 4' 0 " M I N . 5' 0 " M I N . 2' 0" MIN INTERIOR 1' 6" MIN. EXTERIOR REQUIRED CLEAR SPACE REQUIRED CLEAR SPACE PROVIDE THIS ADDITIONAL SPACE IF DOOR HAS A LATCH AND CLOSER PULL SIDE PUSH SIDE MIN. 2' 0" . . 42 " M I N . 48 " M I N I M U M DO O R P R O V I D E D WI T H C L O S E R 48 " M I N . 54 " M I N I M U M DO O R P R O V I D E D WI T H C L O S E R . . . . . *36" MIN. VERIFY EXIT OCCUPANCY LOAD 32" MIN. . 60 " M I N . 24 " M A X . LE N G H T 60" MIN. PR O T R U S I O N MINIMUM CLEAR WIDTH FOR TWO WHEELCHAIRS TERMINATION AT CORRIDORS/ HALL NOTE: 36" MINIMUM IF OCCUPANT LOAD IS LESS THAN 10.60" MIN.DOOR APPROACH AT HALLWAYS LATCH APPROACHDOOR APPROACH AT HALLWAYS HINGE APPROACHVESTIBULE DOORSSPACE AT DOORS FRONT APPROACH DOOR APPROACH AT HALLWAYS LATCH APPROACH MI N 48 " MIN 42" MIN 42"X<48" NOTE: 48" MINIMUM DISTANCE BETWEEN PROTRUSIONS MIN. 11"ú MAX. 6" MI N . 9" ú27 " M I N . CLR. 8" MIN. 34 " M A X . 15 " M I N . 8" MIN. 19" MAX. OF THE 48" CLR. FLOOR SPACE CAN EXTEND UNDER LAVATORY 30"x48" MIN. CLR. FLOOR SPACE KNEE CLEARANCE FROM 9" TO 27" A.F.F. TO BE 11" DEEP REDUCING TO 8" DEEP TOE CLEARANCE FROM 0" TO 9" A.F.F. TO BE 6" DEEP BEYOND KNEE CLEARANCELAVATORY SIDE ELEVATION CL 29 " M I N . LAVATORY NOTES: 1. PROVIDE A CLEAR SPACE 30"X48" MIN. IN FRONT OF THE LAVATORY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACE UNDER LAVATORY. 2. INSULATE OR CONFIGURE HOT WATER SUPPLY AND DRAIN PIPING UNDER LAVATORIES TO PREVENT CONTACT. 3. NO SHARP OR ABRASIVE ELEMENTS ARE ALLOWED UNDER LAVATORIES. 4. FAUCETS CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO BE OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED 5 LBF. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF EXCEPTABLE DESIGN. 5. SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 17" MIN. TO B O T T O M O F M R R O R 40 " M A X . 48 " M I N . 60 " M A X . 1. AT EVERY PRIMARY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL, THERE SHALL BE A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS SHALL INDICATE THE DIRECTION TO ACCESSIBLE BUILDING ENTRANCES AND FACILITIES. 2. WHEN A BUILDING CONTAINS AN ENTRANCE OTHER THAN THE MAIN ENTRANCE WHICH IS RAMPED OR LEVEL FOR USE BY DISABLED PERSONS, A SIGN SHOWING ITS LOCATION IS REQUIRED TO BE POSTED AT OR NEAR THE MAIN ENTRANCE. 3. PROVIDE SIGNS WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY INDICATING LOCATION OF EACH ACCESSIBLE ENTRY. PROVIDE ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED. WINDOW OPERATIOR . 15 " M I N . 48 " M A X . SI D E AP P R O A C H 15 " M I N . 48 " M A X . FR O N T AP P R O A C H CONVINIENCE OUTLET PULL CHORD SWITCH CONVENIENCE OR CONTROL DEVICE CONTROLS, SWITCHES AND OUTLETSNOTES: 1. THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES AND OTHER OPERABLE EQUIPMENT SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION MEETING THE CLEARANCES AND REACH RANGE REQUIREMENTS. 2. CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. 3. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. 4. EXISTING BUILDING MUST MEET SAME REQUIREMENTS AS NEW CONSTRUCTION UNLESS AN UNREASONABLE HARDSHIP IS GRANTED BY THE ENFORCING AGENCY. GRADE 2 BRAILLE RAISED CHARACTERS 48 " M I N . 60 " M A X . FINISHED FLOOR CHARACTERS ON SIGNS SHALL BE RAISED 1/32" MIN. AND HAVE A WIDTH TO HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATIO OF BETWEEN 1:5 AND 1:10. THE MINIMUM CHARACTER HEIGHT SHALL BE 5/8" MIN. AND 2" MAX. AND SANS SHERIF UPPER CASE. GRADE 2 BRAILLE DOTS SHALL BE 1/10" ON CENTER IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY TO THE RIGHT. ADA ROOM IDENTIFICATION SIGN STRIKE SIDE OF DOOR AREA FOR HARDWARE 34 " . 3". 48 " . 48 " M I N . 60 " M A X . UNISEX WOMEN MENGRADE 2 BRAILLE NOTES: 1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. 2. TACTILE CHARACTERS SHALL BE LOCATED 48" MIN. AFF, MEASURED FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER AND 60" MAX. AFF, MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. 3. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR. 4. LETTERS & NUMBERS ON SIGNS SHALL BE RAISED 1/32" MIN., SHALL BE A MIN. OF 5/8" HIGH, A MAX. OF 2" HIGH, & SHALL BE SANS SERIF UPPERCASE CHARACTERS ACCOMPANIED BY CONTRACTED GRADE 2 BRAILLE. OB S T R U C T I O N H E I G H T 34 " M A X . H RE A C H H E I G H T 48 " M A X . REACH DEPTH 24" MAX. D REACH RANGE LIMITS CORRESPONDING REACH HEIGHTS FOR GIVEN DEPTHS: WHEN D = 10" OR LESS, H = 48" MAX. WHEN D = 24", H = 46" MAX. 20" MAX. FORWARD REACH 24" MAX. SIDE REACH, 36" MIN. 27 " . 34 " . 46 " M A X . CL E A R F O R TA B L E S AN D CO U N T E R S 30 " M I N . WI D E @ PA Y P O I N T S ACCESS ON TWO SIDES 36" MIN. ACCESS ON ONE SIDE REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.1 PROJECT NUMBER: 24212 ACCESSIBLITY STANDARDS, NOTES/DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597N.T.S. D7COMPARTMENTS/TOE CLEARANCE N.T.S. D1WATER CLOSET AND TOILET ACCESSORIES NOTES AND INFORMATION N.T.S. A5DOORS N.T.S. K3DOOR OPENINGS & CORRIDORS/HALLS N.T.S. G7LAVATORIES N.T.S. G5ENTRY AND DIRECTIONAL SIGNS N.T.S. G13CONTROLS AND OPERATING MECHANISMS N.T.S. D5EXIT TACTILE SIGN N.T.S. A3RESTROOM SIGNS N.T.S. A1REACH RANGES N.T.S. K1AISLES KB A A B B 1 1 2 2 WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 HALLWAY 111 MEN'S RESTROOM 102 SALES FLOOR 107 PREP AREA 110 CASHIER 108 BACK ROOM 109 WALK IN COOLER 104 (TO FACE OF SIP) 113' 0" 103 102A 101A 101B 3 A8.2 ______ A8.2 4 1 A8.2 ______ A1.3 2 A9.2 3 A9.2 1 A6.1 4 (TO FACE OF SIP) 113' 0" (T O F A C E O F S I P ) 46 ' 0 " EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L 1 A8.2 ______ A8.2 2 A 4 A 9 A 10A 11 A 12A 12 A 12A 12 A 15A 16 A 17 A 17 A 18A 19 A 15 A 15 A 27 A 27 A 27 A 32 A 33 A 38 A 38 A 38 A 39 A 44 A 12A 12 A 27A 27 A 38 A 1A 1 A 41A 41 A 27 101C 101D 102B A 41A 41A 41A 41 A 1A 1 OCCUPANCY: M 63 OCCUPANTS A 47 A 4 A8.2 7 A 45 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EXTERIOR ROOF ACCESS LADDER A 2A 2 A 7 108A A 7 A 7A 25 B 108B C A 7 A 25 A B A 25 A 36 BC S A 41A 41 A 1A 1A 15 CO2 A 35 A 36 (T O F A C E O F S I P ) 46 ' 0 " A 22 6 A8.1 ______A8.2 6 6 A8.1 ______ A6.1 2 6 A8.1 ______ 4 A9.2 ______ 3 A8.2 ______ A8.2 2 A8.2 7 1 A4.0 ______1 A4.0 ______ 3 A4.0 ______ 3 A4.0 ______ A 37 A 9 _______ A2.1 2 _______ A2.1 1 _______ A2.1 3 _______ A2.1 4 A 31 A 9A 37 A 9 A 37 A 21 A 15 A 32 A 37 A 9 107 A 11 BELOW 4R V Z C 3 0 T 2 4R V Z C 3 0 4R V Z C 3 0 4R V Z C 3 0 T 2 BC S ATM WINE RACK A8.3 6 A 41A 41 A 41 TYP. A 31 A 13 A 44A 44 A 37 A 3 A 37 A 37 A 25 A 14 A 9 TYP. A 31 COMMISSARY RACKS A 41 A 32A 32 A 32 A 32 A 4 A 2A 2 A 32 A 32 A 50 A 42 A 38 A 42 A 48 A 41 A 17 A 6 A 4 A 4 A 43 A 43 A 6 A 15 A 6 A 15 A 6 A 4 A 27 A 10 A 6 A 4 A 4A 5 A 30 A 29 A 15 A 4 111 A 26 A 49 SHUT OFF SHUT OFFA 30 A 30 6 5/8" SIP WALL PANEL. SEE SIP VENDOR SHEETS 6" 20ga. METAL STUD AT 16" O.C. WITH BATT INSULATION. SEE SHEET A1.3 FOR WALL TYPES 3 5/8" 20ga. METAL STUD AT 16" O.C. (WITH BATT INSULATION IF APPLICABLE) SEE SHEET A1.3 FOR WALL TYPES 3 5/8" 20ga. METAL STUD AT 16" O.C. TO DECK WITH BATT INSULATION. SEE SHEET A1.3 FOR WALL TYPES 3 5/8" METAL STUD FURRED WALL (WHERE OCCURS) AT 16" O.C. FIBER CEMENT WAINSCOT/ PILASTER PRE MANUFACTURED FREEZER/COOLER WALL SIP PANEL WALL W/ F.R.P. PANELING, SEE KEYNOTES & SHT. A3.2 3/4" FRT. PLYWOOD W/ F.R.P. PANELING, SEE KEYNOTES 37 & SHT. A3.2 WINDOW TYPE: SEE WINDOWS SCHEDULE SHEET A6.0 DOOR TYPE: SEE DOOR SCHEDULE SHEET A6.0 X X REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.2 PROJECT NUMBER: 24212 FLOOR PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3/16" = 1' 0" 1FLOOR PLAN NUMBER DESCRIPTION A 1 CONCRETE SLAB WITH MINIMUM 15ML 'CLASS A' VAPOR BARRIER LAPPED A MINIMUM OF 6" & TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL A 2 CONCRETE WALK, BROOM FINISH, SEE CIVIL A 3 EXTERIOR ROOF ACCESS LADDER, SEE DETAIL 7/A8.3 A 4 CUSTOM CASEWORK SUPPLIED BY CIRCLE K, INSTALLED BY OTHERS A 5 SALES COUNTER, SEE SHEET A1.4 FOR EQUIPMENT. A 6 SOLID SURFACE COUNTER TOP SUPPLIED BY CIRCLE K, INSTALLED BY OTHERS A 7 ALUMINUM STOREFRONT SYSTEM, SEE SHEET A6.0 FOR DOOR & WINDOW SCHEDULES A 9 PEBBLE SURFACE MARLITE F.R.P. PANELING TO 6" ABOVE FINISH CEILING, P 100 WHITE, OR EQUAL. SEE SHT. A3.2. A 10 PROVIDE INTEGRAL SPLASH GUARD AT HAND SINK A 11 5 LB. 2A 10BC FIRE EXTINGUISHER, SURFACE MOUNTED AT 48" A.F.F., PROVIDE BLOCKING AS REQUIRED A 12 COOLER/FREEZER PROVIDED AND INSTALLED BY CIRCLE K. GENERAL CONTRACTOR RESPONSIBLE FOR ELECTRICAL AND PLUMBING CONNECTIONS. A 13 COOLER REACH IN DOOR, SUPPLIED/INSTALLED BY COOLER/FREEZER MANUFACTURER A 14 COLD VAULT DOOR & WINDOW, SUPPLIED/INSTALLED BY COOLER/FREEZER BY MANUFACTURER A 15 FLOOR SINK ACCESSIBLE FOR CLEANING, SEE PLUMBING DRAWING A 16 MOP SINK WITH FAUCET, SEE PLUMBING DRAWING FOR SPECIFIC INFORMATION (G.C. TO ADD 24" LONG GARDEN HOSE FOR MOP SINK FAUCET). A 17 HAND SINK, SEE PLUMBING DRAWINGS FOR SPECIFIC INFORMATION A 18 3 COMPARTMENT SINK, SEE PLUMBING DRAWINGS FOR SPECIFIC INFORMATION A 19 50 GALLON WATER HEATER ON SHELF ABOVE, SEE PLUMBING AND ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION A 21 LOCATION OF ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION A 22 LOCATION OF SERVICE DISCONNECT. IF REQUIRED, PROVIDE 4" CONCRETE HOUSEKEEPING PAD ABOVE SIDEWALK UNDER CABINET COORDINATE SIZE AND LOCATION PAD AND CABINET WITH ELECTRICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION. A 25 LINE OF CANOPY / SOFFIT ABOVE, SEE REFLECTED CEILING PLAN SHEET A1.6 AND EXT. ELEVATIONS SHEET A2.1 A 26 KNOX BOX LOCATION, SEE RECESS DETAILS 1/A8.1 (IF REQUIRED BY FIRE DEPARTMENT) A 27 PROVIDE SIGN ABOVE HAND SINK "EMPLOYEE MUST WASH HANDS BEFORE RETURNING TO WORK" A 29 34" HIGH ACCESSIBLE COUNTERTOP A 30 FUEL EMERGENCY SHUT OFF SWITCH WITH COVER, PROPOSED LOCATION WHEN REQUIRED, SEE FUEL PLAN. A 31 SIPS PANEL WALL, SEE DETAIL 8/A8.1, SIP SHEETS, STRUCTURAL, BUILDING SECTIONS AND EXTERIOR ELEVS. A 32 2" STAINLESS STEEL CORNER GUARDS TO 54" A.F.F. A 33 4" CONC. CURB AT ELECTRICAL PANELS A 35 CO2 TANK AT EXTERIOR WITH STORAGE TANK CABINET. SEE DET. 2/A9.1 FOR REQUIRED SIGNS. A 36 HOSE BIBB, SEE PLUMBING DRAWINGS A 37 FRP PANELING, SEE LEGEND AND SHT. A3.2. A 38 STORAGE LOFT, SEE INTERIOR ELEVATIONS FOR HEIGHT, SEE DETAIL 4/A9.2 OR ALTERNATE LOFT DETAIL 12/A9.2 A 39 FURRED OUT WALL TO CLOSE GAP BETWEEN WALL AND WALK IN COOLER FROM BOTTOM TO CEILING, SEE DETAIL 6/A9.2 A 41 FRP TILE FINISH, SEE FINISH SCHEDULE AND SHEETS A1.11, A3.1 & 3.3 A 42 LINE OF SOFFIT ABOVE A 43 PROVIDE HUB DRAIN AND ROUTE DRAIN TO NEAREST FLOOR SINK, SEE PLUMBING DRAWINGS A 44 BREAK METAL TO CLOSE GAP BETWEEN WALL AND WALK IN COOLER FROM BOTTOM TO CEILING, SEE DETAIL 3/A9.2 A 45 G.C. TO PROVIDE METAL KEY STORAGE BOX FROM GRAINGER MFR. A 47 6"X6" PIPE CHASE. A 48 WALK IN FREEZER RAMP, SUPPLIED/INSTALLED BY COOLER/FREEZER MANUFACTURER A 49 HI LO DRINKING FOUNTAIN. A 50 FILLER PANEL VENDOR PROVIDED, GC TO INSTALL. KEY NOTES LEGEND A A B B 1 1 2 2 WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 WALK IN COOLER 104 BACK ROOM 109 SALES FLOOR 107 HALLWAY 111 A A EE B E B 6' 11 1/2" 3' 0" 22' 0 1/4" (T O F A C E O F S I P ) 46 ' 0 " F F A9.3 4 A9.3 3 (TO FACE OF SIP) 113' 0" (T O F A C E O F S I P ) 46 ' 0 " CO2 PREP AREA 110 CASHIER 108 F 6' 0 " 1' 8 " USE 6" MTL. STUD 7' 1 1/2" 6' 0"7' 7 1/2" 45' 7 1/2" 11' 5 1/2" 8' 5" 7' 8 1/2" D 4' 1" 10' 9 1/2" (4) EQ. PANELS WINDOW 16' 10" 4' 0" 3' 2" (3) EQ. PANELS WINDOW 12' 8" 4' 2" (3) EQ. PANELS WINDOW 12' 8" 3' 2" 4' 0" 4' 4" (2) EQ. PANEL WINDOWS 8' 4" 6' 1 1/2" 4' 1" 7' 3 1/2" (TO FACE OF SIP) 113' 0" 10 ' 9 1 / 2 " 20' 9" 16' 0 3/8" 16' 7 7/8" 5' 9 5/8" FFF F F BC S BC S F. O . P . F. O . P . F. O . P . F. O . P . F. O . P . F. O . P . 21' 4" 80' 2 1/2" 11' 5 1/2" A1.3 2 F.O.P. F.O.P. 16' 7" 22' 10" 44' 8 3/8" 28' 10 3/4" EXTERIOR ROOF ACCESS LADDER F.O.P. F.O.P. 1' 6 " A A USE 3 5/8" MTL. STUD 7' 8" 31' 8" 5' 9" 22' 10" 5' 9" 31' 8" 7' 8" C 3 3 / 4 " 3 3 / 4 " A EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L 4' 6"2' 5 1/2" WH 4R V Z C 3 0 T 2 4 R V Z C 3 0 4R V Z C 3 0 4R V Z C 3 0 T 2 1 A4.0 ______1 A4.0 ______ 3 A4.0 ______ 3 A4.0 ______ 4 A4.0 ______ 4 A4.0 ______ USE 6" METAL STUD 4' 1 0 1 / 2 " 2' 7 1 / 2 " 6' 8 1 / 2 " A FA C A D E A B O V E 3' 1 " F.O.P. 12 ' 8 " 5 ' 4 " 2 8 ' 0 " F. O . P . F. O . P . F. O . P . F. O . P . F. O . P . F. O . P . F. O . P . F. O . P . F.O.P. F.O.P. F.O.P. F.O.P. 7' 8 " D AIR GAP 1" MIN. 8' 5 " 7' 3 1/2" AIR GAP 1" MIN. 10' 6 1/4" 5' 4" 7' 8 " 5 ' 0 " 7' 8 " 26 ' 1 1 3 / 4 " 26' 7" 24' 7 1/2" 2 6 ° 1' 6 " 5 ' 8 1 / 2 " 2 ' 9 1 / 4 " 2' 0 " 2' 1 1 " 11' 4 1/4" 7' 3 1 / 2 " 4' 0" 6' 4 5 / 8 " 3 ' 4 1 / 2 " 3 ' 5 " 3 ' 4 1 / 2 " 7 ' 2 1 / 2 " 4' 4 1/4" 2' 11 1/2" 4' 6" 2' 11 1/2" 4' 6" 2' 11 1/2" 5' 0" 2' 11 1/2" 10' 6 3/8" 5 1/4" MEN'S RESTROOM 102 WOMEN'S RESTROOM 101 VE E D E R RO O T 17 ' 2 1 / 4 " 1' 3 " 6' 9 " 9 ' 2 " 30 ' 7 3 / 4 " 4' 7 " 4' 9 1 / 4 " 7' 9 1/2" 5' 0"11' 0 1/2" 14' 0 1/2" 26' 10" 10' 5 1/2" 3' 0" 4' 10" 2' 6" 4' 0" 6' 0" 6' 6" 17 ' 4 7 / 8 " 5' 6 " 2 ' 0 " 2 ' 0 " 2 ' 0 " 4 ' 1 0 7 / 8 " 35 ' 6 3 / 4 " 5' 0" 4' 7 " 5' 0 " 5' 0"4' 0" 5' 5 " 4' 1 " 4' 6" USE 6" METAL STUD A3.33D 3C 3B 3A A3.3 4C 4D 4A 4B B 23 B 16 B 10 B 1 B 2 B 11 B 13 B 11B 11 B 1 B 11 B 7 B 11 B 10 B 10 B 10 B 16 B 3 B 8 B 23 B 9 B 10 B 10 B 12 B 23 60" MIN. 5' 0 1/4"CLEAR 12" MIN. 1' 6 " 6' 3 1 / 2 " 3 ' 2 " 3 ' 6 " 3 ' 1 1 / 2 " B 15 B 14 B 23 B 16 B 16 B 3 B 8 B 10 RR SIGN SEE 1/A9.1 2' 10 1/2" 12' 4 1/2" 4' 0" B 10 B 10 B 10 RR SIGN SEE 1/A9.1 B 10 B 11 B 10 B 2 B 10B 10 B 10B 10 B 6 B 10 B 12 B 10 B 10B 10 60" MIN. 5' 0 1/4" B 15 6' 3 1 / 2 " 3 ' 6 " 3 ' 2 " 3 ' 2 " 4' 6 1 / 2 " 2 2 ' 5 " 60" MIN. 5' 0 1/4" B 14 6' 0" CL CL CL CL CL CL CL B 24 B 10B 10 BC S BC S B 15 B 14 WC WC WC A3.3 6 UR B 2 B 19 B 6 B 10 B 10 B 5 B 18 UR MEN'S RESTROOM 102 WC B 10 B 10 B 10 B 10 B 10B 10B 10 B 25 CL E A R T YP . 5' 0 3 / 8 " M I N . CL E A R T YP . 5' 0 3 / 8 " M I N . B 22 B 1B 1 B 26 B 17 10' 5 1/2" 9' 11 1/2" 7' 1 1/2"7' 3 1/8" 20' 4 1/2" 4' 0" B 10 B 14 B 19CLEAR 5' 0"B 5 B 5 1' 4 1 / 2 " B 22 B 8 B 8 B 19 B 19 B 14 B 6 B 15 CLEAR 5' 0 1/2" 2' 9 " 2' 9 " 3' 1 " 1' 6 1 / 2 " 3' 1 " 1' 7 " 2' 9 " 1' 4 1 / 2 " 2' 9 " B 5 B 5 B 13 B 6 B 25 B 2 B 19 WOMEN'S RESTROOM 101 B 4 B 2 B 7 B 2 B 10B 10B 10 B 10B 10B 10 B 10B 10B 10 B 18 B 5B 19 B 14 B 12 B 12 B 12 B 12 B 12 B 12 5' 9 1 / 2 " A9.1 7 CL 5' 11 1/8" 1' 3" 2' 3" 1' 0" 6' 7 1/2" 3' 3" 1' 0" 3' 6" 3' 3" 3 ' 6 " A3.3 8 1. ALL INTERIOR NON METAL SURFACES TO BE PAINTED SHALL BE PRIMED WITH SHERWIN WILLIAMS ProMar® 200 Zero VOC Interior Latex Primer 2. ALL INTERIOR METAL SURFACES TO BE PAINTED SHALL BE PRIMED WITH SHERWIN WILLIAMS Pro Industrial™ Pro Cryl® Universal Acrylic Primer 3. ALL INTERIOR SURFACES TO BE PAINTED SHALL BE PAINTED WITH SHERWIN WILLIAMS Duration Home® Interior Acrylic Latex Paint ** SEE SHEET A2.1 "EXTERIOR ELEVATIONS" FOR PAINT TYPE SELECTION OF EXTERIOR WALLS ** DRYWALL INTERIOR/EXTERIOR DRYWALL MUST BE CLEAN AND DRY. ALL NAIL HEADS MUST BE SET AND SPACKLED. JOINTS MUST BE TAPED AND COVERED WITH A JOINT COMPOUND. SPACKLED NAIL HEADS AND TAPE JOINTS MUST BE SANDED SMOOTH AND ALL DUST REMOVED PRIOR TO PAINTING. EXTERIOR SURFACES MUST BE SPACKLED WITH EXTERIOR GRADE COMPOUNDS. STEEL SOLVENT CLEANING SOLVENT CLEANING IS A METHOD FOR REMOVING ALL VISIBLE OIL, GREASE, SOIL, DRAWING AND CUTTING COMPOUNDS, AND OTHER SOLUBLE CONTAMINANTS. SOLVENT CLEANING DOES NOT REMOVE RUST OR MILL SCALE. CHANGE RAGS AND CLEANING SOLUTION FREQUENTLY SO THAT DEPOSITS OF OIL AND GREASE ARE NOT SPREAD OVER ADDITIONAL AREAS IN THE CLEANING PROCESS. BE SURE TO ALLOW ADEQUATE VENTILATION. WOOD INTERIOR ALL FINISHING LUMBER AND FLOORING MUST BE STORED IN DRY, WARM ROOMS TO PREVENT ABSORPTION OF MOISTURE, SHRINKAGE, AND ROUGHENING OF THE WOOD. ALL SURFACES MUST BE SANDED SMOOTH, WITH THE GRAIN, NEVER ACROSS IT. SURFACE BLEMISHES MUST BE CORRECTED AND THE AREA CLEANED OF DUST BEFORE COATING. RESTROOM SIGN NOTE: SIGNS DENOTING THE RESTROOMS SHALL INCLUDE LETTERS AND NUMERALS THAT ARE RAISED 1/32", UPPER CASE, SANS SERIF OR SIMPLE SANS SERIF AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. MOUNTING HEIGHTS FOR THE SIGNS DENOTING THE RESTROOMS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR, MEASURED FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. MOUNTING LOCATION FOR THE SIGN SHALL BE SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF THE SIGN WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. A. WALL TYPE 'A', SEE 3/A9.1 B. WALL TYPE 'B', SEE 6/A9.1 C. WALL TYPE 'C', SEE 9/A9.1 D. WALL TYPE 'D', SEE 12/A9.1 E. WALL TYPE 'E', SEE 11/A9.1 F. WALL TYPE 'F', SEE 10/A9.1 & 7/A9.1 NOTES: A. SEE ROOM FINISH SCHEDULE ON SHEET A1.11. B. SEE EQUIPMENT SCHEDULE ON SHEETS A1.4, A1.5.1, A1.5.2 AND A1.5.3 C. SEE DETAIL 5/A3.3 FOR RESTROOM TYPICAL WALL TILE PATTERN. D. SEE SHEET A3.3 FOR RESTROOM ELEVATIONS AND DETAILS. 1. INTERIOR DIMENSIONS SHOWN ARE TO INTERIOR WALL FINISH, UNLESS OTHERWISE NOTED. 2. EXTERIOR DIMENSIONS SHOWN ARE TO FACE OF SIP WALL PANELS, UNLESS OTHERWISE NOTED. 3. SEE SHEETS A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT. 4. COORDINATE ALL DIMENSIONS IN AREAS OF WALK IN COOLERS WITH EQUIPMENT INSTALLERS. 5. INSTALL FULL THICKNESS ACOUSTICAL BATT INSULATION CONTINUOUS TO ROOF DECK IN ALL WALLS SEPARATING RESTROOMS FROM ADJACENT CONVENIENCE STORE AREAS. INSULATION TO BE NON COMBUSTIBLE, BEARING THE U.L. CLASSIFICATION MARKING. 6. BRACE STUDS ABOVE CEILING AS REQUIRED TO PROVIDE RIGID WALLS THROUGHOUT, SEE STRUCTURAL DRAWINGS. 7. ALL CABINETS IN FOOD OFFERING AREA, INCLUDING COFFEE BAR AND SALES COUNTER, TO HAVE SOLID TOP WITH METAL SIDES PAINTED AND KICK PLATE BASE PAINTED "BLACK". 8. USE FDA APPROVED FOOD GRADE CLEAR CAULKING BETWEEN COUNTERTOPS AND WALLS AND WHERE REQUIRED PER LOCAL AND COUNTY HEALTH DEPARTMENT REQUIREMENTS. 9. GENERAL CONTRACTOR SHALL COORDINATE WITH THE EQUIPMENT AND DRYWALL INSTALLERS TO ENSURE THAT ALL ELECTRICAL WIRING, WATER LINES AND REFRIGERATION LINES HAVE BEEN INSTALLED PROPERLY ON ALL EQUIPMENT PRIOR TO THE HANGING OF ANY DRYWALL, SEE THE CIRCLE K PROJECT MANAGER FOR ANY EQUIPMENT LOCATION CLARIFICATIONS. 10.PROVIDE 5/8" MOISTURE RESISTANT GYPSUM WALLBOARD THROUGHOUT, BEHIND COOLER/FREEZER, RESTROOMS, BEHIND 3 COMP SINK, BEHIND FRONT COUNTER UNDER GLASS, MOP SINK AND HOT WATER HEATER. 11.SEE SHEET A1.11 FOR ROOM FINISH SCHEDULE. 12.SEE SHEETS A3.1, A3.2, AND A3.3 FOR INTERIOR ELEVATIONS. NOTE: SERVICE HOSE SHALL BE FLEXIBLE POLYOLEFIN HOSE FOR MEDIUM PRESSURE SERVICE (STYLE 540P), COMPLIANT WITH FDA TITLE 21 FOR FOOD CONTACT, AND HAVE A MAXIMUM WORKING PRESSURE OF 2000 PSI. ALL PIPING, REGULATORS, AND PRESSURE REGULATORS SHALL BE KEPT TIGHT TO PREVENT LEAKAGE OF ANY CO2 GASES, AS PER NFPA 55:7.3.1.3.1 (2018 EDITION) CO2 SHALL BE EQUIPPED W/ AN EMERGENCY SHUT OFF DEVICE, AS PER NFPA 55:7.3.11 (2018 EDITION) EXTERIOR SIDE BACKROOM SIDE SEAL INTERIOR SIDE W/ SPRAY FOAM INSULATION. STUB OUT WALL 6" ABOVE FINISHED CEILING ROUTE TO FTN MACHINES. LINE TO BYPASS ALL ELECTRICAL & MECHANICAL CONNECTIONS SEAL EXTERIOR SIDE W/NP1 CONSTRUCTION GRADE SEALANT 1 1/2" PVC CHASE HOSE WD. TRUSS SYSTEM HOSE 6" . 10 ' 8 " T O U N D E R S I D E O F C E I L I N G 5' 6 " . CO2 TANK SIP WALL 6 5/8" SIP WALL PANEL. SEE SIP VENDOR SHEETS 6" 20ga. METAL STUD AT 16" O.C. WITH BATT INSULATION. SEE SHEET A1.3 FOR WALL TYPES 3 5/8" 20ga. METAL STUD AT 16" O.C. (WITH BATT INSULATION IF APPLICABLE) SEE SHEET A1.3 FOR WALL TYPES 3 5/8" 20ga. METAL STUD AT 16" O.C. TO DECK WITH BATT INSULATION. SEE SHEET A1.3 FOR WALL TYPES 3 5/8" METAL STUD FURRED WALL (WHERE OCCURS) AT 16" O.C. FIBER CEMENT WAINSCOT/ PILASTER PRE MANUFACTURED FREEZER/COOLER WALL SIP PANEL WALL W/ F.R.P. PANELING, SEE KEYNOTES & SHT. A3.2 3/4" FRT. PLYWOOD W/ F.R.P. PANELING, SEE KEYNOTES 37 & SHT. A3.2 WINDOW TYPE: SEE WINDOWS SCHEDULE SHEET A6.0 DOOR TYPE: SEE DOOR SCHEDULE SHEET A6.0 X X REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.3 PROJECT NUMBER: 24212 DIMENSIONED FLOOR PLAN, WALL TYPES, AND ENLARGED RESTROOM CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 NUMBER DESCRIPTION B 1 30"x48" ADA ACCESSIBLE SPACE AT LAV. B 2 PARTITION B 3 COUNTERTOP (SUPPLIED BY CK AND INSTALLED BY OTHERS) B 4 36"x48" ADA ACCESSIBLE SPACE AT URINAL B 5 CONVENIENCE HOOKS B 6 GRAB BAR 1 1/4" 1 1/2" DIAMETER, PROVIDE ADEQUATE BLOCKING. FOR EXTERIOR WALLS GC TO UTILIZE BLOCKING PROVIDED IN SIP. B 7 FLOOR DRAIN, SEE PLUMBING DWGS. B 8 INSULATED WATER AND DRAIN PIPES B 9 60" DIA. MIN. CLEAR FOR WHEELCHAIR B 10 FRP PANEL WALL B 11 PORCELAIN TILE FLOORS B 12 STEEL POST, SEE DETAIL 7/A9.1 'A' B 13 TOILET FLUSH VALVES TO BE ON THE WIDE SIDE OF STALL B 14 TOILET PAPER DISPENSER B 15 SANITARY NAPKIN DISPOSAL B 16 MIRROR B 17 SOLID BLOCKING AT WALL FOR ALL MOUNTED EQUIPMENT B 18 FLOOR SHALL SLOPE 1% TO DRAIN B 19 TOILET SEAT COVER DISPENSER B 22 BABY CHANGING TABLE TO BE INSTALLED BY G.C. REFER TO SIP DETAIL FOR EXTERIOR WALL INSTALLATION B 23 SOAP DISPENSERS B 24 S.S. TRASH CAN B 25 CONVENIENCE SHELF B 26 HAND DRYER WALL TYPES GENERAL NOTES LEGEND PAINTED SURFACES PREPARATION NOTES PAINT TYPE SPECIFICATION NOTES RESTROOMS KEY NOTES 3/16" = 1' 0" 1DIMENSIONED FLOOR PLAN SE 3/8" = 1' 0" 2ENLARGED RESTROOM PLAN SE 3" = 1' 0" 3CO2 CHASE LINE DETAIL A3.33D 3C 3B 3A A3.3 4C A A B B 4D 4A 4B 1 1 2 2 A3.3 2A 2C 2D A3.2 1B 1A 1D 1C A3.22D 2A 2B 2C A3.2 3A A3.2 4A 3B 3C 3D 4D 4C 4B A3.1 1A 1B 1C 1D S008 S008 S008 S008 S008S008S008 S003 S003 S003 S003 S003 S003 S007 S007 R101 B502 A9.1 2 WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 WALK IN COOLER 104 MEN'S RESTROOM 102 BACK ROOM 109 SALES FLOOR 107 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 HALLWAY 111 TRASH CAN (T O F A C E O F S I P ) 46 ' 0 " A9.1 1 LOTTO MACHINE SUNGLASS & CELL PHONE TELE COM LOTTO STAND (TO FACE OF SIP) 113' 0" (TO FACE OF SIP) 113' 0" 17 COOLER DOORS P403 M009 P403 R203 M104 S008 S008 S008 S008 S008S008S008 S003 S003 S003 S003 S003 S003 S007 V201 B501 P411 A9.1 1 TRASH CAN S008 FE PLATFORM R001 (T O F A C E O F S I P ) 46 ' 0 " C02 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L BC S CASHIER 108 PREP AREA 110 P411 F.S. COMMISSARY RACKS TRASH TRASH TRASH RE A C H I N F R E E Z E R 4 D O O R S 3 SIDED ENDCAP S007 BC S B504 _______ A2.1 2 (QTY. 2) (BELOW) (QTY. 2) (BELOW) WINE RACK R006 M012 BACK ROOM 109 18192021 R210 P102P101 P404 O008P311 P301 P301 O007 O008 P102 O007P304 O007P304 O007P304 P307 O008 P301 P301 O008 P404 P309 P311 P306 P106P108 P308P308 P307 P309 P309 P101 P305 P305 P101 P102 P305 P101 P102 P309 P106 P108 P105 P105 P108 P106 P306 P106P108 S007 R008 R007 R007 R007 R007 R007 R007 R007 R007 R007R007R007R007R007R007R007 P401 ABOVE BELOW R401 P201 P203 P001P002 P403O010P408P202O008 EXTERIOR ROOF ACCESS LADDER CB T D E S K BFP RACK MOP BUCKET F.D. ** * E L E C T R I C A L P A N E L C L E A R A N C E A R E A F.S. BELOW7 PS 60 ADVANCE BI B B I B B I B B I B B I B V001 V001 V001 V001 ** * O V E R H E A D ST O R A G E V004 V002 V003 V008 F007 F006 F005 B404 B403 B406 B405 B301 B405 V201 B101 B102 B507 B001 B002B505 B002B505B001 B301 B002B505B001 FE MUGS 12 H E A D FO U N T A I N W/ C U B E D I C E 12 H E A D FO U N T A I N W/ C U B E D I C E 12 H E A D FO U N T A I N W/ C U B E D I C E COLD CUP TOWER (2 ) T E A BR E W E R S CORNELI US 4 Head Froster VIPER CORNELI US 4 Head Froster VIPER DOME LIDS DISPENSER LIDS DISPENSER LIDS DISPENSER COLD CUP TOWER WA T E R F I L T E R EV 9 3 2 9 4 4 S003 S003 S003 S003 S003 S003 S003 S003 M011 M108 P404 B101 4' NOVELTY CASE T301 O003 O004 V007 T003 T201 T202T302 T303T304 V005 O010 V006 B603 B603 B603 B603 B603 O002O006 S101 ABOVE QTY. 4 FI L E CA B NE T W O R K I N G RA C K 6' 5 4 " X 3 6 " X 1 6 " B A S E 6' 5 4 " X 3 6 " X 1 6 " B A S E 6' 5 4 " X 3 6 " X 1 6 " B A S E 6' 5 4 " X 3 6 " X 1 6 " B A S E 12' 66" X 36" X 19" BASE 12' 66" X 36" X 19" BASE UC CIG 4' TOBACCO (54" TALL) 2' CIGS (54" TALL) 2' C I G S (6 4 " T A L L ) 2' CIGS (54" TALL) 2' C I G S (6 4 " T A L L ) 2' C I G S (6 4 " T A L L ) 8" P E G G E D / SH E L V E S B E L O W 6" SIDESPLASH ST O R A G E FL E X SP A C E FL E X SP A C E CO A T S 12" PEGGED/SHELVES BELOW FL O O R F A N S P A C E B E L O W HAND SINK UNOX OVENW/ HOOD UNOX OVENRACK 27 P A N E U R O B A K E R Y C A S E 48 " R E F R I G E R A T E D WO R K T A B L E OR G A N I Z E R 24 I N SM A L L W A R E S CA B I N E T PLASTICTRASH CAN F.D. LO C K A B L E CA R T O N ST O R A G E LO C K A B L E CA R T O N ST O R A G E LO C K A B L E CA R T O N ST O R A G E LO C K A B L E CA R T O N ST O R A G E K1 1 5 1 5 12" PEGGED/SHELVES BELOW 12" PEGGED/SHELVES BELOW 12" PEGGED/SHELVES BELOWSCANNERPRINTERMONITOR CASH BOXDNR MONITOR 32" CLEAR FOR SAFE SCANNER MO N I T O R CA S H B O X PRINTER 3' C I G S (6 4 " T A L L ) DESK MG R CO M P U T E R 3 D R A W E R S PLASTIC TRASH CAN 3' C I G S (6 4 " T A L L ) R006 F207 4R V Z C 3 0 T 2 4R V Z C 3 0 T 2 4R V Z C 3 0 4R V Z C 3 0 P102 P102 P101P302 P310P305O007P101 O007P302P305 P310 P304 T101 H401 V105 H201 H202H203 T107 T107 H211 R202H205 H302 T007 T105 T104 T104 R206 T010 T011 T011 T010 T001 T002 T008 T005T009 H301 P403 P404 T003 T004 T006 P204 M107 P403 P402 WOMEN'S RESTROOM 101 MUGSM011 WIRE RACK UNOX SPEEDPRO OVEN27" UNDER COUNTER FREEZER P406 MONITOR KEYBOARD PR I N T E R T003T001T005 T006T007T002 T004 T008T009 SMART DESK BE E R T U B 30 I N X 5 4 I N M014 DNR T012 T106 P413 M016 M016 M016 M016 M016M016M016M016M016M016M016M016M016 M016M016 M016 M016 M016 M016 M016 M016 M001 M001 M001 M001 M001 M001 VE E D E R RO O T R102 RAMP O008 PIPE CHASE TO W E L O005P205 M006 M007 M007 PACKAGED BAKERY SHADOWBOX WITH NESTING TABLES COFFEE CONDIMENT ISLAND C001 C107C107C001C001 (3) BREW ON DEMAND UNITS I. C . C U P / LI D D I S P . I. C . C U P / LI D D I S P . 6" S I D E S P L A S H K115155 HEAD CAPPUCCINO TE A P A C K E T S RA C K ICED COFFEE THEATER NI T R O CU P S NI T R O IC E MA C H I N E CU P S TOWEL P204O008C002 C106 P205 C004 C005C202 R310 P403 R309 11' 0" X 4' 0" SOUTHERN CASE ARTS ISLAND MERCHANDISER H209H209 O001 H108 H106 H303 H005H001H003 H206 H208 H104 O001 H001H003 O001 O001 H103 B006B006 PIZZA SPINNER CONDIMENT WARM RACK PIZZA WARMER PLATFORM (2) HOT DOG GRILL ACRYLIC BUN DISPLAY (2) MICROWAVES BELOW 4 P A N C O L D CO N D I M E N T BO T T L E CO N D I M E N T S PA C K A G E D BA K E R Y 36" FLEXSERVE HEATED MECHANDISERS 36" FLEXSERVE HEATED MECHANDISERS BEV. COOLER BEV. COOLER A3.3 8 B503 B503 B503 TOWEL O005 O005 H107 R207 UN D E R C O U N T E R RE F R I G E R A T O R RICOS NACHOS H109H110H111 C111 V004 V004 S003S003 OP E N AI R CO O L E R 12' 36" X 18" X 19" BASEM001 WATER PODS (MEADOW BROOK) WATER PODS (ZEPHYRHILLS) WATER PODS (ZEPHYRHILLS) WATER PODS (CNF) WATER PODS (CNF) Z001Z001 Z001 Z001 Z001Z001Z001 M101 M101 M102 B003 B003 M002 M105 P309 P403 R007 R007 R007 R007 F207 F207 C109 C109 P309 P103 P103 P104 P104 P305 V105 H207 T108 T109 V101 P414 END UNIT END UNIT END UNIT END UNITEND UNITEND UNITEND UNIT EN D U N I T P412 V207 V207 V004 1. SEE SHEET A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT LIST 2. EQUIPMENT SYMBOL 3. VERIFY EQUIPMENT LAYOUT WITH CIRCLE K 4. SEE SHEETS A3.1, A3.2, AND A3.3 FOR INTERIOR ELEVATIONS. * . . . . A REAR B RIGHT C FRONT D LEFT RM. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.4 PROJECT NUMBER: 24212 EQUIPMENT PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 GENERAL NOTES ROOM REFERENCE ORIENTATION 3/16" = 1' 0" 1EQUIPMENT PLAN SE REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.5.1 PROJECT NUMBER: 24212 EQUIPMENT LIST CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 C STORE EQUIPMENT SCHEDULE A1.5.1 EQUIPMENT CATEGORY Sub category CK ITEM # ITEM NAME NOT SHOWN IN PLAN USE DESCRIPTION QTY Manufacturer Model RESPONSIBILTY ELECTRICAL WATER WASTE REMARKS PR O T O T Y P E F I N I S H S C H E D U L E SUPPLIED BY INSTALLED BY MEP BY AM P S ( M C A ) Vo l t s Ph a s e PL U G DI R E C T PL U G & C O R D B Y G C FI L T E R E D FI L T E R & D E S C A L E CO L D HO T DI R E C T IN D I R E C T BEVERAGE AND ICE FOUNTAIN B001 12 HD SODA FOUNTAIN PACKAGE CORNELIUS FOUNTAIN/ADAPTER/LEGS 3 CORNELIUS ENDURO 300 CK CK GC 5.2 120 V 5 15P X X X 3/4" MAIN TRUNK LINE FROM FILTER, TEE 1/2" LINE W/ BRASS BALL VALVE AND 3/8" FLARE FITTING TO EACH PIECE OF EQUIPMENT BEVERAGE AND ICE FOUNTAIN B002 CARBONATOR FOR ED300 1 PER FOUNTAIN 3 CORNELIUS *416424000 CK CK GC 7.2 120 V 5 15P X 1/4" FLARE CO2 INLET, 3/8" FLARE WATER INLET, 3/8" FLARE SODA WATER OUTLET. TO BE INSTALLED ON SHELF ON TOP OF BIB RACK BEVERAGE AND ICE FOUNTAIN B003 TEA BREWER PACKAGE W/ (3) TCN URNS AND SS TRAY 2 WILBUR CURTIS RSTB, (3)TCN, DT24 CK CK GC 13.8 120 V 5 15P X 3/4" MAIN TRUNK LINE FROM FILTER, TEE 3/8" LINE W/ BRASS BALL VALVE, VENDOR TO INSTALL FROM SHUTOFF TO UNIT BEVERAGE AND ICE COLD B006 BEVERAGE COOLER 2 VARIES VARIES CK CK GC 2.2 115 V BEVERAGE AND ICE ICE B101 19" FOLLETT REMOTE CHEWBLET ICE ICE MAKER (1800LB) 1 OR 2 FOUNTAINS 2 FOLLETT HCD1810RHT CK CK GC 5.0 120 V 5 15P X X X <MOPD 15A>3/8" WATER LINE FROM SCALE INHIBITOR; 1/2"DRAIN LINE, GC TO PROVIDE CORD AND PLUG NEMA 5 15, REQUIRES DEDICATED 15A CIRCUIT BEVERAGE AND ICE ICE B102 30" MANITOWOC REMOTE ICE MAKER (1825LB) 1 FOUNTAIN AND/OR BAGGER 1 MANITOWOC IYF 1800C 161 CK CK GC 1.1 120 V 5 15P X X X <MOPD 15A>3/8" WATER LINE FROM SCALE INHIBITOR; 1/2"DRAIN LINE, GC TO PROVIDE CORD AND PLUG NEMA 5 15 BEVERAGE AND ICE ICE REF. B201 REMOTE CONDENSER FOR HCD1818RHT W/ LINE SET CONDENSER FOR ICE MACHINE 2 FOLLETT CK CK GC 15.7 208 V 3 X REFERENCE REFRIGERATON VENDOR DRAWINGS BEVERAGE AND ICE ICE REF. B202 REMOTE CONDENSER FOR IYF1800C W/LINE SET OPTIONAL 2ND ONE FOR BAGGER 1 MANITOWOC CVDF1800F 263A CK CK GC 20.0 208 V 3 X REFERENCE REFRIGERATON VENDOR DRAWINGS BEVERAGE AND ICE FROZEN B301 FOUR BARREL COUNTERTOP FCB PACKAGE STANDARD TO BE INSTALLED ON 4" LEGS W/ TALL TRANSLITE 2 CORNELIUS VIPER ELITE 4B CK CK GC 28.8 208 V L630P X X <208/1PH MCA 28.8A/FLA 23.1A/MOCP 30A W/BUCK BOOST>3/4" MAIN TRUNK LINE FROM FILTER, TEE 1/2" LINE W/BRASS BALL VALVE AND 3/8" FLARE FITTING TO EACH PIECE OF EQUIPMENT; 30PSI MIN. GC TO DO ELECT. ONLY BEVERAGE AND ICE DISPENSERS B403 COUNTERTOP CUP/LID DISPENSER CUPS LEFT 1 GENERUX FINE W.P. CUSTOM CK CK BEVERAGE AND ICE DISPENSERS B404 COUNTERTOP CUP/LID DISPENSER CUPS RIGHT 1 GENERUX FINE W.P. CUSTOM CK CK BEVERAGE AND ICE DISPENSERS B405 COUNTERTOP FCB DOME LID DISPENSER 2 FOOD CONCEPTS CK DOMELID CK CK BEVERAGE AND ICE DISPENSERS B406 COUNTERTOP LID/STRAW DISPENSER 1 FOOD CONCEPTS CK DISLIDST FOUNT CK CK BEVERAGE AND ICE MISC. B501 CO2 TANK 1 CARBOMIZER VARIES VENDOR VENDOR VENDOR BEVERAGE AND ICE MISC. B502 CO2 CABINET 1 ROYSTON CUSTOM CK CK BEVERAGE AND ICE MISC. B503 CO2 DETECTION SYSTEM X 1 LOGICO2 MK9 VENDOR VENDOR VENDOR 1.0 120 V 5 15P PROVIDED AND INSTALLED BY CO2 VENDOR, GC TO PROVIDE A SINGLE OUTLET ONLY NEAR THE BIB RACKS. BEVERAGE AND ICE MISC. B504 CO2 SIGNS X 1 NUCO2 VENDOR VENDOR BEVERAGE AND ICE MISC. B505 LEG SHROUD FOR ENDURO300 FOUNTAIN X ONE PER FOUNTAIN UNIT 3 FOOD CONCEPTS CK FTN ENDUROSHRD CK CK BEVERAGE AND ICE MISC. B507 LEG SHROUD FOR FCB X ONE PER FCB 2 FOOD CONCEPTS CK FTN FCBSHROUD CK CK BEVERAGE AND ICE BIB B603 3 WIDE BIB RACK PACKAGE PACKAGE WITH 5 SHELVES AND PUMP MOUNT 5 CORNELIUS 3BIFJ CK CK FOUNTAIN RACKS ARE PREASSEMBLED WITH SHELF AND PUMPS ALREADY MOUNTED. FCB AND OTHER REQUIRE ASSEMBLY AND PUMPS TO BE PROVIDED AND/OR MOUNTED BY CONTRACTOR. COFFEE BREWERS C001 3 HOPPER BEAN TO CUP BREWER 3 SCHAERER 040381 00058EUS CK VENDOR GC 16.0 208 V L620P X X SCHAERER CHECKLIST MUST BE COMPLETE L6 20R 250VAC, 20AMP, 1 PHASE, RANGE 205 240V, 20AMP BREAKER, 3" HOLE PER BREWER, 3/8" COMPRESSION SHUTOFF, 30 60PSI PRESSURE; HUB, WATER AND POWER 36" FROM MACHINE LOCATION COFFEE BREWERS C002 5 HD CAPPUCCINO 1 WILBUR CURTIS PCGT5 CK CK GC 15.0 120 V 5 15P X 3/4" MAIN TRUNK LINE FROM FILTER TO COFFEE BAR, TEE 1/2" LINE W/ BRASS BALL VALVE AND 1/4" FLARE FITTING TO EACH PIECE OF EQUIPMENT; SINGLE OUTLET COFFEE BREWERS C003 BEAN TO CUP COFFEE WATER FILTER X ONE PER SET OF (3) BEAN TO CUP BREWERS 3 SCHAERER HF40 S CK VENDOR VENDOR X COFFEE COND/MISC. C004 COLD DRAFT COFFEE DISPENSER COLD DRAFT COFFEE DISPENSER 1 BUNN NITRON COLD DRAFT C TOP 4:1 12:1 WITH REMOVABLE DOOR GRAPHIC CK CK GC 6 120 V 1 NEMA 5 15 P COFFEE COND/MISC. C005 COLD BREW COFFEE DISPENSER COLD BREW COFFEE DISPENSER 1 BUNN NITRON COLD DRAFT ALL NITRO W/RDG & NGM CK CK GC 6 120 V NEMA 5 15 P COFFEE COND/MISC. C106 TEA RACK 1 PURELEAF CK PURELEAF RACK 6 D S CK CK COFFEE COND/MISC. C107 ICED COFFEE CUP/LID DISPENSER 2 LIBERTY CUSTOM CK CK COFFEE COND/MISC. C108 4HD COFFEE CREAMER 1 DANONE ID 400 VENDOR CK GC 2.8 120 V 5 15P COFFEE COND/MISC. C111 REFRIGERATED COLD PANS NSF 7 REFRIGERATED COLD PANS 1 WELLS RCP 7200 CK CK GC 4.9 115 V NEMA 5 15 P REFERENCE TO CABINET VENDOR DRAWINGS COFFEE COND/MISC. C202 ICE AND WATER DISPENSER ICE AND WATER DISPENSER 1 FOLLETT 15CI100A NW NF ST 00 15 SERIES CHEWBLET ICE MACHINE AND WATER DISPENSER CK CK GC 5.0 115 V DECOR CATEGORIES D001 COFFEE BACKGROUND DÉCOR X INCLUDES WALL PANEL AND LETTERS 1 CUSTOM CK CK WALL COVERING OR ACRYLIC PANEL AND LETTERING DECOR CATEGORIES D002 POLAR POP DÉCOR PACKAGE X INCL. PP SIGN & HEADER PANELS 1 CUSTOM CK CK INCLUDES HANGING SIGNAGE, COIN FOR POLAR POP DECOR CATEGORIES D003 FROSTER DÉCOR PACKAGE X INCL. FROSTER SIGN, HEADER PANELS & FRAMES 1 CUSTOM CK CK INCLUDES HANGING SIGNAGE, COIN FOR FROSTER DECOR CATEGORIES D005 HOT FOOD DÉCOR PACKAGE X INCLUDES WALL PANEL AND LETTERS 1 CUSTOM CK CK INCLUDES HANGING SIGNAGE, COIN FOR FROSTER DECOR CATEGORIES D006 GRILL DÉCOR & POP PACKAGE X INCLUDES GRILL DRAWER KITS 1 CUSTOM CK CK INCLUDES ALL DECOR AND SINGNAGE NEEDED FOR HOT FOODS AREA DECOR POP D101 24"X36" BACKLIT LED FRAMES 1 CUSTOM CK CK GC 120 V 5 15P BACKLIT SNAP FRAMES FOR POP AND MENUS DECOR COLD D201 COOLERWALL DÉCOR PACKAGE X INCLUDES HEADER PANELS & ICONS 1 CUSTOM CK CK INCLUDES BUTTONS FOR ABOVE COOLER DOORS DECOR COLD D202 FREEZER WALL DÉCOR PACKAGE X INCLUDES HEADER PANELS & ICONS 1 CUSTOM CK CK INCLUDES BUTTONS FOR ABOVE COOLER DOORS DECOR COLD D203 COLD VAULT SIGN BACKLIT 1 CUSTOM CK CK GC 120 V 5 15P BACKLIT COLD VAULT LETTERING DECOR COLD D204 COLD VAULT GRAPHICS PACKAGE X 1 CUSTOM CK CK INCLUDES ALL DECOR AND SINGNAGE NEEDED FOR BEVERAGE CAVES INCLUDING COLD VAULT WALL COVERING DECOR CENTER D301 CENTER STORE HALO ELEMENT MERCHANDISING (TAKE IT EASY) X HALO & LETTERS 1 CUSTOM CK CK SUSPENDED ELEMENT AND WORD COPY NO POWER REQUIRED DECOR CENTER D302 CENTER STORE HALO ELEMENT CHEKCOUT (PAY HERE/NICE TO SEE YOU) X HALO & LETTERS 1 CUSTOM CK CK SUSPENDED ELEMENT AND WORD COPY NO POWER REQUIRED DECOR CENTER D303 CENTER STORE HALO ELEMENT FOOD (GOOD TO GO) X HALO & LETTERS 1 CUSTOM CK CK SUSPENDED ELEMENT AND WORD COPY NO POWER REQUIRED DECOR CENTER D304 RESTROOM DÉCOR SIGNS X 1 CUSTOM GC CK GC 120 V 5 15P RESTROOM SIGN ON BULKHEAD ABOVE COORIDOR AND RESTROOM ENTRANCE FUEL & FORCOURT FUEL F001 FUEL TANKS X 1 FS/XERXES/MODERN CUSTOM CK PETRO FUEL & FORCOURT FUEL F002 FUEL DISPENSERS X 1 GILBARCO 700S CK PETRO PETRO X X REFR TO PETRO PLANS FOR ELECTRICAL REQUIREMENTS FUEL & FORCOURT FUEL F003 PETROLEUM EQUIPMENT AND PIPING X 1 ANS VARIES CK PETRO PETRO FUEL & FORCOURT FUEL F004 SUBMERSIBLE TANK PUMPS (STP)X 1 RED JACKET VARIES CK PETRO PETRO X X REFR TO PETRO PLANS FOR ELECTRICAL REQUIREMENTS FUEL & FORCOURT FUEL F005 VEEDER ROOT X 1 VEEDER ROOT TLS 450PLUS CK PETRO PETRO 2.0 115 V X FUEL & FORCOURT FUEL F006 INTERCOM X 1 3M D2400 PETRO PETRO PETRO 8.0 120 V 5 15P IG QUADRUPLEX OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL. (PROVIDED AND INSTALLED BY PETROLEUM CONTRACTOR) FUEL & FORCOURT FUEL F007 PUMP CONTROL PANEL 1 FEPETRO STP SCI CK PETRO PETRO 30.0 120 V X FUEL & FORCOURT SITE F101 CANOPY & INSTALL X 1 JIMCO/ARNING N/A CK CANOPY FUEL & FORCOURT SITE F102 SITE SIGNAGE X 1 S.R./PATTISON N/A CK SIGN GC X X REFER TO SIGN VENDOR FOR ELECTRICAL REQUIREMENT FOR MID AND BUILDING SIGNS FUEL & FORCOURT SITE F103 3'x6' ELECTRONIC MESSAGE CENTER (EMC) X 1 ABLE N/A CK SIGN GC 15.0 120 V X REFER TO SIGN VENDOR FOR ELECTRICAL REQUIREMENT FOR MID AND BUILDING SIGNS FUEL & FORCOURT SITE F104 4'x8' ELECTRONIC MESSAGE CENTER (EMC) X 1 ABLE N/A CK SIGN GC 26.7 120 V X REFER TO SIGN VENDOR FOR ELECTRICAL REQUIREMENT FOR MID AND BUILDING SIGNS FUEL & FORCOURT MISC. F206 BOLLARD COVERS X 1 POSTGUARD VARIES CK GC/OPS GC. TO ASSEMBLE, OPERATIONS TO PLACE FUEL & FORCOURT MISC. F207 HOODED TRASH 3 MASONWAYS ARU/TB47 FUEL & FORCOURT MISC. F208 SINGLE SIDED AMENITY UNIT 1 MASONWAYS ARU2 HOT FOODS HOT DOGS H001 50 HOT DOG ROLLER GRILL (DURATIC ROLLS) 2 STAR 50SCBDEP CK CK GC 12.8 120 V 5 15P HOT FOODS HOT DOGS H002 SLANTED GLASS SNEEZE GUARD FOR STAR 50 GRILL X 2 CREATIVE DISPLAY CDW HT LED 50 CK CK GC 1.0 120 V 5 15P ASSEMBLED BY GC HOT FOODS HOT DOGS H003 4" BLACK STEEL LEGS HOT DOG GRILLS (WITH RUBBER FEET) (4 PER KIT) X 2 STAR RGLK KIT CK CK ALL GRILL NEED 4" LEGS, EXTEND ALL THE WAY OUT AND H004 THERMO DRAWER IS INSTALL ON COUNTERTOP UNDER EACH GRILL HOT FOODS HOT DOGS H005 BUN DISPLAY 1 DESERT STAR CK 10038 CK CK GC 1.2 120 V 5 15P HOT FOODS HOT DOGS H006 11" LED POP DISPLAY 1 CREATIVE DIPLAY 11 LED POP CK CK GC 1.2 120 V 5 15P HOT FOODS HOT DOGS H007 HOT DOG GRILL DIVIDER KIT X 1 FOOD CONCEPTS CK RG DK SCBD 50 CK CK GC 1 KIT PER GRILL HOT FOODS CONDIMENTS H103 4 BIN COLD CONDIMENT DISPENSER DROP IN 1 APW RTR 4DI CK CK GC 3.0 120 V 5 15P STAINLESS STEEL EXTERIOR & FOOD WELLS; HOLDS (6) 1/8 SIZE 4" DEEP PANS (PANS & COVER INCLUDED), CUTOUT FOR COUNTERTOP 16 11/16X 15 11/16 HOT FOODS CONDIMENTS H104 4 BIN COLD CONDIMENT DISPENSER COUNTERTOP 1 APW RTR 4 CK CK GC 3.0 120 V 5 15P STAINLESS STEEL EXTERIOR & FOOD WELLS; HOLDS (6) 1/8 SIZE 4" DEEP PANS (PANS & COVER INCLUDED), CUTOUT FOR COUNTERTOP 16 11/16X 15 11/16 HOT FOODS CONDIMENTS H106 WIRE SAUCES / CONDIMENT RACK 1 WIRECRAFT PMRK0404 CK CK HOT FOODS CONDIMENTS H107 CORRAL WIDE WITH 3 STEPS CONDIMENT RACK 1 DESERT STAR 10060 CK CK HOT FOODS CONDIMENTS H108 CONDIMENT CADDY WITH SOLID BASE 1 DESERT STAR 700641 CK CK HOT FOODS CONDIMENTS H109 3 TIER CHIP RACK RICOS 3 TIER CHIP RACK 1 RICOS #813936 3 TIER CHIP RACK CK CK NACHOS TO GO RACK AND 3 TIER CHIP RACK HOT FOODS CONDIMENTS H110 NACHOS TO GO RACK RICOS NACHOS TO GO RACK 1 RICOS #813035 NACHOS TO GO RACK CK CK NACHOS TO GO RACK AND 3 TIER CHIP RACK HOT FOODS CONDIMENTS H111 CHEESE CUP RACK RICOS CHEEESE CUP RACK 1 RICOS #813034 CHEESE CUP RACK CK CK NACHOS TO GO RACK AND 3 TIER CHIP RACK HOT FOODS HOT FOOD H201 ELECTRIC COMBI OVEN 1 UNOX XAVC 0511 EPR CK VENDOR GC 19.0 208 V 15 20P X X SEE SPEC SHEET FOR POWER SUPPLY & WATER REQUIREMENTS HOT FOODS HOT FOOD H202 UNOX VENTLESS HOOD X 1 UNOX XAVHC HC11 CK VENDOR GC 0.5 208 V 6 15P SEE SPEC SHEET FOR POWER SUPPLY & WATER REQUIREMENTS HOT FOODS HOT FOOD H203 UNOX OVEN STAND W/ PAN RACK X 1 UNOX XWVRC 0711 UH CUSTOM CK VENDOR HOT FOODS HOT FOOD H205 UNOX SPEEDPRO OVEN STAND X FOR USE WHEN STORE ONLY GETS 1 UNOX SPEED PRO 1 YES GROUP TBD CK CK HOT FOODS HOT FOOD H206 PIZZA WARMER W/ CIRCLE RACK W/ MOTOR 1 HATCO FSDT 1 CK CK GC 11.8 120 V 5 15P HOT FOODS HOT FOOD H207 PIZZA WARMER CURVE APPEAL X 1 HATCO FSD CTLH BK CK CK HOT FOODS HOT FOOD H208 PIZZA WARMER PLATFORM X 1 DESERT STAR 10026 18 CK CK HOT FOODS HOT FOOD H209 DISPLAY WARMER 2 FLEXESERVE 1000 CK CK GC 13.0 208 V 6 20P HOT FOODS HOT FOOD H211 UNOX SPEEDPRO OVEN 1 UNOX BAKERLUX SPEED.Pro CK CK GC 18 208 V NOT INCLUDED HOT FOODS MISC. H301 FOOD AT SCALE SMALLWARE PACKAGE X ONE PACKAGE PER FOOD CONVENIENCE STORE 1 E TUNDRA VARIOUS CK CK HOT FOODS MISC. H302 DAYMARK PRINTERS PACKAGE X PART OF SMALLWARES FOR FOOD 1 DAYMARK MATT85 CK CK GC 2.0 120 V 5 15P IG HOT FOODS MISC. H303 COMMERCIAL MICROWAVE OVEN 2 MENUMASTER MMS10TS CK CK GC 12.5 120 V 5 15P COMMERCIAL GRADE MICROWAVE HOT FOODS BAKERY H401 LARGE BAKERY CASE 1 JSI CK BAKE FXT017 CK CK GC 3.0 120 V 5 15P MARKETING FIXTURES CENTER STORE M001 INLINE GONDOLA PACKAGE 1 LOZIER/RPS/ROYSTON PACKAGE CK VENDOR CIRCLE K TO SUPPLY AND GC TO ASSEMBLE AND PLACE MARKETING FIXTURES CENTER STORE M002 COLD VAULT SHELVING PACKAGE 1 ETALEX QUOTE CK CK ASSEMBLED BY GC MARKETING FIXTURES CENTER STORE M006 LARGE NESTING TABLE LM TABLE 1 JSI LM TABLE CK CK MARKETING FIXTURES CENTER STORE M007 SMALL NESTING TABLE SM TABLE 2 JSI SM TABLE CK CK REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.5.2 PROJECT NUMBER: 24212 EQUIPMENT LIST CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 C STORE EQUIPMENT SCHEDULE A1.5.2 EQUIPMENT CATEGORY Sub category CK ITEM #ITEM NAME NOT SHOWN IN PLAN USE DESCRIPTION QTY Manufacturer Model RESPONSIBILTY ELECTRICAL WATER WASTE REMARKS PR O T O T Y P E F I N I S H S C H E D U L E SUPPLIED BY INSTALLED BY MEP BY AM P S ( M C A ) Vo l t s Ph a s e PL U G DI R E C T PL U G & C O R D B Y G C FI L T E R E D FI L T E R & D E S C A L E CO L D HO T DI R E C T IN D I R E C T MARKETING FIXTURES CENTER STORE M009 CENTER STORE DISPLAY PLATFORM 1 VARIES VARIES CK CK GC. TO ASSEMBLE, OPERATIONS TO PLACE MARKETING FIXTURES CENTER STORE M010 FRUIT STAND 1 MOBILE MERCH. K1430/3B MB CK CK GC. TO ASSEMBLE, OPERATIONS TO PLACE MARKETING FIXTURES CENTER STORE M011 MUG DISPLAY/RACK COUNTERTOP MODEL 2 FOOD CONCEPTS CK FTN RFLMR 2A CK CK MARKETING FIXTURES CENTER STORE M012 WINE DISPLAY FIXTURE 102" 1 AMERICAN DISPLAY CUSTOM CK CK GC 1.0 120 V 5 15P (2) STANDARD QUAD OUTLETS ON 1 CIRCUIT AT 86" AFF ABOVE WINE FIXTURE SEE PLANS MARKETING FIXTURES CENTER STORE M014 BEER TUB 30"x54" 1 CREATIVE DISPLAY CUSTOM MARKETING FIXTURES CENTER STORE M016 COOLER SHELVING PACKAGE 1 BRUEGMANN GROUP CUSTOM CK CK ASSEMBLED BY GC MARKETING FIXTURES EXTERIOR EQUIPMENT M101 PROPANE PAD OPTIONAL 2 LEER VARIES MARKETING FIXTURES SERVICES M102 WATER DISPENSER OPTIONAL 1 GLACIER G218 VENDOR VENDOR GC 20.0 120 V 5 20P X X X X EACH MACHINE MUST HAVE DEDICATED 20 AMP RECEPTICLE, (1) 1/2" WATER LINE PER (3) MACHINE 15 PSI MINIMUM, EACH UNIT TO HAVE DEDICATED BALL VALVE SHUTOFF, INDIRECT DRAIN. MARKETING FIXTURES SERVICES M104 LOTTERY VENDING UNIT OPTIONAL 1 VARIES VARIES VENDOR VENDOR GC 120 V 5 15P OPTIONAL MARKETING FIXTURES SERVICES M105 ICE MERCHANDISER OPTIONAL 1 LEER VARIES MARKETING FIXTURES SERVICES M106 AIR/WATER COMBINED X 1 VENWORKS HYGEIA VENDOR VENDOR GC 30.0 120 V X VENDOR SUPPLIED AND INSTALLED, GC TO RUN ELECTRICAL 3/4" CONDUIT, #10 WIRE W/ GROUND. STUB UP BEHIND PAD. PAD TO BE 60"X36" SEE CIVIL PLANS MARKETING FIXTURES SERVICES M107 ATM MACHINE 1 TRITON RL5000 CK VENDOR GC 2.0 120 V 5 15P IG DEDICATED ISOLATED GROUND POWER, PHONE LINE, AND DATA LINE MARKETING FIXTURES SERVICES M108 BITCOIN MACHINE 1 BITCOIN DEPOT 145 V MARKETING FIXTURES INT MISC. M201 WE ID SIGN X 1 A.B. N/A VENDOR CK GC 1.0 115 V 5 15P PROVIDE SINGLE OUTLET FOR POWER ONLY PER DRAWINGS MARKETING FIXTURES INT MISC. M202 PUSHER TRAYS, CHANNEL RAILS, PEGS HOOKS X 1 TRION INDUSTRIES VARIOUS CK OPS MARKETING FIXTURES INT MISC. M203 COOLER GLIDES BY BRUGEMANN X 1 PFI VARIOUS CK OPS MARKETING FIXTURES INT MISC. M204 POP BACK STRIPS X 1 GLADSON VARIOUS CK OPS MARKETING FIXTURES INT MISC. M301 SIDEWALK A FRAME SIGNAGE DISPLAY X 1 MAGICMASTER QLA GI CK OPS MARKETING FIXTURES INT MISC. M302 PUMP APPROACH SNAP FRAMES X 1 KDM POP SOL VARIOUS CK OPS MARKETING FIXTURES INT MISC. M303 INVERTED PUMP TOPPERS X 1 HICORP DB650SA CK CK MARKETING FIXTURES INT MISC. M304 BUILDING SNAP FRAMES X 1 VARIES VARIES CK GC OPERATIONS O001 NAPKIN DISPENSER 4 MCLANE N/A CK OPS COMES FROM MCLANE INSTALLED AT TIME OF OPERATION SETUP OPERATIONS O002 MANAGER DESK 1 ROYSTON CUSTOM CK VENDOR OPERATIONS O003 MANAGER CHAIR 1 OFFICE DEPOT LORELL 722306 CK OPS OPERATIONS O004 TELEPHONE 1 VTECH 532343 CK OPS VENDOR OPERATIONS O005 PAPER TOWEL DISPENSER TORK 3 TORK 5511282 CK GC PROVIDED BY OPERATIONS, USES REFILL 754374 OPERATIONS O006 SAFETY CABINET OPTIONAL 1 VARIES VARIES CK VENDOR OPERATIONS O007 TOILET PAPER DISPENSER 6 TORK 555528A CK GC PROVIDED BY OPERATIONS, USES REFILL 638916 OPERATIONS O008 SOAP DISPENSER 7 MCLANE/COREMARK 299743 CK GC PROVIDED BY OPERATIONS, USES REFILL MCLANE 570416 OPERATIONS O009 OPERATIONAL EXCELLENCE PACKAGE X 1 VARIES VARIES CK OPS/CK OPERATIONS O010 SAFEWORLD CLEANING KIT X 2 SAFE WORLD 429712 CK GC ORDERED BY MARKETING/ OPS FROM MCLANE OPERATIONS O011 CHEMICAL DISPENSER(S) X 1 DEMA PF651 OR PF652 CK GC SINGLE DISPENSER FOR MOP SINK, DUAL DISPENSER FOR 30COMP AS REQUIRED. PLUMBING WAREWASH P001 3 COMPARTMENT SINK W/ (2) 18" DRAIN BOARDS FAUCET SEPARATE 1 ADVANCE TAB 9 3 54 18RL CK GC GC X PROVIDE W/ PRE RINSE, OVERFLOW AND ADAPTA FAUCET; PLUMBING HOOK UP BY GC PLUMBING WAREWASH P002 PRE RINSE UNIT W/ FAUCET 1 KROWNE 17 109W CK GC GC X X WALL MOUNT, BASE FAUCET, 6" WALL BRACKET PLUMBING RESTROOMS P101 TOILET 6 AMERICAN STAND 3043.001 GC GC GC X TOILET SEAT #5901.100, WAX RING, AND CLOSET BOLTS TO BE PROVIDED WITH TOILET PLUMBING RESTROOMS P102 TOILET FLUSH VALVE AUTOMATIC HARDWIRED X 6 SLOAN SLOAN 111 ESS 1.28 TMO HW GC GC GC 1.5 120 V 5 15P X PLUMBING RESTROOMS P103 URINAL 2 AMERICAN STAND K 5016 ER 0 GC GC GC X PLUMBING RESTROOMS P104 URINAL FLUSH VALVE AUTOMATIC HARDWIRED X 2 SLOAN SLOAN 186 ESS 0.5 TMO HW GC GC GC 1.5 120 V 5 15P X PLUMBING RESTROOMS P105 RESTROOM VANITY COUNTERTOP 2 ROYSTON CUSTOM CK VENDOR X PLUMBING RESTROOMS P106 RESTROOM UNDERMOUNT LAVATORY BOWL 4 ROYSTON INTEGRATED GC VENDOR GC X PLUMBING RESTROOMS P108 HAND SINK FAUCET AUTOMATIC HARDWIRED 4 SLOAN SF 2400 GC GC GC 1.5 120 V 5 15 P X X HARDWIRED; FULL MODEL NUMBER SF 2400 4 PLG TEE CP 0.5GPM MLM IR FCT PLUMBING MISC SINKS P201 MOP SINK 1 MUSTEE 63M GC GC GC X PLUMBING MISC SINKS P202 MOP SINK FAUCET 1 AMERICAN STAND. 8344.012 GC GC GC X X PLUMBING MISC SINKS P203 WALL MOUNTED HAND SINK INCLUDES FAUCET 1 ADVANCE TAB 7 PS 60 CK GC GC X X X PLUMBING MISC SINKS P204 DROP IN HAND SINK 2 ELKAY OR EQUAL K11515 CK GC GC X X X SINK AND FAUCET SUPPLIED WITH ROYSTON CABINETS PLUMBING MISC SINKS P205 GOOSENECK FAUCET FOR DROP IN HAND SINK FAUCET HAND SINK WALL MOUNTED 2 CHICAGO FAUCETS 895 317CP CK GC GC X X X SINK AND FAUCET SUPPLIED WITH ROYSTON CABINETS PLUMBING RESTROOM ACC. P301 ANGLE FRAME MIRROR 4 BOBRICK B 290 GC GC PLUMBING RESTROOM ACC. P302 ADA HAND RAILS 2 BOBRICK B 5806 GC GC PLUMBING RESTROOM ACC. P304 WALL MOUNTED SANITARY NAPKIN DISPOSAL RECEPTACLE WOMEN'S COMPARTMENTS ONLY 4 BOBRICK B 270 GC GC PLUMBING RESTROOM ACC. P305 TOILET SEAT COVER DISPENSER 6 BOBRICK B 4221 GC GC PLUMBING RESTROOM ACC. P306 LAVATORY GAURD FOR HAND SINK 4 TRU BRO 102EZ GC GC PLUMBING RESTROOM ACC. P307 HORIZONTAL BABY CHANGING STATION OPTIONAL 2 BRADLEY 962 11 GC GC PLUMBING RESTROOMS ACC. P308 RESTROOM SIGNS 2 LOCKNET TBD GC GC PLUMBING RESTROOM ACC. P309 COAT HOOK 6 BOBRICK B 212 GC GC PLUMBING RESTROOMS ACC. P310 CONVENIENCE SHELF 2 BOBRICK B296 18 GC GC PLUMBING RESTROOMS ACC. P311 HAND DRYER EXCEL 2 EXCEL TA ABS CK GC 7 120 V X INSTALLER TO SET HEAT TO LOW PLUMBING MISC. P400 FIXED BLADDER TYPE EXPANSION TANK X 1 AMTROL FLEXCON / WATTS WLILKINS ST 12 / WH 18 / PLT 12 / XT 18 PLUMBING MISC. P401 ELECTRIC WATER HEATER ELECTRICAL SPECS VARY PER SIZE 1 AO SMITH DRE 52 24 GC GC GC 66.6 208 V X X X SPECS WILL VARY PER ARCHITECTS PLUMBING SCHEDULE PLEASE SEE MANUFACTURER DATA FOR ELECTRICAL AND /OR GAS SPECS PLUMBING MISC. P402 WATER FILTER 1 EVERPURE EV9437 10 CK GC GC X 1/2" NPT CONNECTION, PROVIDED BY FACILITIES PLUMBING MISC. P403 FLOOR SINK 7 ZURN Z1901 GC GC GC X PLEASE USE COMPONENTS LISTED WITH FLOOR SINK; P1900 SEMI DONE; GRATE TYPE WILL DEPEND ON LOCATION AND USE, VERIFY WITH CM DURING SUBMITTALS. PLUMBING MISC. P404 FLOOR DRAIN W/ TRAP PRIMER 4 WADE 1002STD6.1 GC GC GC X X SATIN NICKEL STRAINER PLUMBING SANITARY P405 FLOOR CLEANOUT FLOOR CLEANOUT 4 J.R. SMITH 4100 SERIES GC GC GC NICKEL BRONZE TOP. TWIST TO FLOOR ADJUSTMENT PLUMBING MISC. P406 BACKFLOW PREVENTER INLINE BEVERAGE CHECK VALVE X 1 WATTS SD3 GC GC GC X PLUMBING MISC. P407 1/4 TURN BRASS SHUTOFF VALVE X 1 FNW OR EQUAL VARIES GC GC GC 1/4 TURN BRASS BALL VALVE REQUIRED FOR ALL SHUTOFFS SIZE AND TYPE WILL VARY FOR APPLICATION, USE LEAD FREE IN INSULATIONS THAT WHERE WATER IS ATTACHED TO BEVERAGE EQUIPMENT OR DRINKING FOUNTAINS. PLUMBING MISC. P408 MIXING VALVE 1 ZURN ZW1017XL GC GC GC X X PLUMBING MISC. P409 CIRCULATION PUMP RECIRCULATION PUMP 1 TACO 003 BC4 GC GC GC 0.43 115 V 1 PLUMBING MISC. P411 ENCASED NON FREEZE HOSE BIB 2 MIFAB MHY 35 GC GC GC X PLUMBING MISC. P412 RECESSED GREASE TRAP X 1 JENSEN PRECAST JP750G GC GC GC X AHJ DETERMINES SIZE PLUMBING MISC. P413 DRINKING FOUNTAINS 1 OAISIS PG8ACSLTM GC GC GC 4.6 120 V 5 15P X X ONLY INSTALL IF REQUIRED BY AHJ PLUMBING P414 WATER PRESSURE BOOSTER PUMP WATER PRESSURE BOOSTER PUMP 1 XYLEM 2AB310HME02 PLUMBING MISC. P415 BACKFLOW PREVENTER RPZ ASSEMBLY 1 WATTS SS009 GC GC GC X ONLY INSTALL IF AHJ REQUIRES PLUMBING MISC. P416 BACKFLOW PREVENTER DC ASSEMBLY 1 WATTS LF007 GC GC GC X ONLY INSTALL IF AHJ REQUIRES PLUMBING MISC. P417 FREEZLESS ROOF HYDRANT 1 WOODFORD RHY2 MS GC GC GC X PLUMBING MISC. P418 TRAP PRIMER 5 SIOUX CHIEF SERIES 695 REFRIGERATION WIC R001 WALK IN COOLER 1 CROWN TONKA CUSTOM CK CK GC PLUMBING WIC R002 WALK IN COOLER EVAPORATOR 3 HTPG RUSSELL DOE RL6A141DDARE CK CK GC 2.9 120 V X X R404 REFRIGERANT PAGE 15 OF QUOTE PLUMBING WIC R003 WALK IN COLER REMOTE CONDENSER 1 HTPG RUSSELL DOE RFO4004SEAALNT CK CK GC 27.7 208 V X X R404 REFRIGERANT, 45AMP MOPD DISCONNECT ATTACHED TO CONDENSER RACK PLUMBING WIC R004 COLD VAULT EVAPORATOR 1 HTPG RUSSELL DOE RE6A204DDARE CK CK GC 3.6 120 V X X R404 REFRIGERANT PAGE 15 OF QUOTE PLUMBING WIC R005 COLD VAULT REMOTE CONDENSER 1 HTPG RUSSELL DOE RFO300E4SEAALNT CK CK GC 27.7 208 V X X R404 REFRIGERANT, 45AMP MOPD DISCONNECT ATTACHED TO CONDENSER RACK REFRIGERATION WIC R006 WALK IN METAL DOOR 36" WIDE 2 CROWN TONKA SELF CLOSE OVERLAP CK CK GC REFRIGERATION REACH IN R007 WALK IN DOORS 30X75 INCLUDES 36" SHELVING 21 ANTHONY 101 CK CK NO HEATERS IN DOOR REFRIGERATION WIC R008 COLD VAULT DOORS 1 ANTHONY 103B CK CK NO HEATERS IN DOOR REFRIGERATION WIF R101 WALK IN FREEZER 1 CROWN TONKA CUSTOM CK CK GC REFRIGERATION WIF R102 WALK IN FREEZER METAL DOOR 36" WIDE 1 CROWN TONKA SELF CLOSE OVERLAP CK CK GC 1.5 115 V X REFRIGERATION WIF R103 EVAPORATOR WALK IN FREEZER EVAPORATOR 1 HTPG RUSSELL DOE RL6E077DDARE CK CK GC 8.9 208 V 1 X X REFERENCE REFRIGERATON VENDOR DRAWINGS REFRIGERATION WIF R104 CONDENSER RACKS WALK IN FREEZER REMOTE CONDENSER 1 HTPG RUSSELL DOE RFO300L4SEANT CK CK GC 14.4 208 V 3 X REFERENCE REFRIGERATON VENDOR DRAWINGS REFRIGERATION REACH IN R202 27" UNDERCOUNTER FREEZER 1 TRUE TUC 27F LP HC CK CK GC 4.0 120 V 5 15P COMES WITH 8' CORD & 3" CASTORS REFRIGERATION REACH IN R203 4 DOOR GLASS DOOR FREEZER 4 DOOR UNIT 1 Zero Zone 4RHZC30 CK CK GC 13.9 208 V X X REFRIGERATION REACH IN R204 4 DOOR GLASS DOOR FREEZER CONDENSER 1 HEATCRAFT BCH0008LCAZ CK CK GC 20.0 208 V X X ELECTRIC DEFROST MOPD 20AMP, MCA 20AMP REFRIGERATION REACH IN R206 48" UNDERCOUNTER REFRIGERATOR 1 TRUE TUC 48 LP HC CK CK GC 2.3 120 V 5 15P REFRIGERATION REACH IN R207 27" UNDERCOUNTER REFRIGERATOR ORDER WITH 3" CASTERS 1 BEVERAGE AIR UCR 27 014 CK CK GC 2.5 120 V 5 15P TO BE INSTALLED UNDERCOUNTER AT THE HOT DOG ISLAND, MUST ORDER WITH 3" CASTERS REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.5.3 PROJECT NUMBER: 24212 EQUIPMENT LIST CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 C STORE EQUIPMENT SCHEDULE A1.5.3 EQUIPMENT CATEGORY Sub category CK ITEM #ITEM NAME NOT SHOWN IN PLAN USE DESCRIPTION QTY Manufacturer Model RESPONSIBILTY ELECTRICAL WATER WASTE REMARKS PR O T O T Y P E F I N I S H S C H E D U L E SUPPLIED BY INSTALLED BY MEP BY AM P S ( M C A ) Vo l t s Ph a s e PL U G DI R E C T PL U G & C O R D B Y G C FI L T E R E D FI L T E R & D E S C A L E CO L D HO T DI R E C T IN D I R E C T REFRIGERATION REACH IN R210 1 DOOR WINE REFRIGERATOR 1 TRUE GDM 26 HC TSL 01 CK CK GC 5.4 120 V 5 15P REFRIGERATION OPEN R309 ISLAND FRESH CASE 4'X11' NEW SPEC 1 SOUTHERN CASE ARTS 11.2 MDI 3M2P R CK GC GC 2.9 120 V 1 X X 1.24A FOR LIGHTS, 1.70A FOR FANS HARDWIRED REFRIGERATION OPEN R310 REMOTE CONDENSER FOR SOUTHERN FRESH CASE NEW SPEC 2 CK GC GC 20.9 208 V X X COMES WITH BOTH ISLAND FROM SOUTHERN CASE ARTS, MOPD 30AMPS, R404 REFIGERANT, 7/8 SUCTION LINE, 1/2 LIQUID LINE REFRIGERATION MISC. R401 BUBBLE TOP ICE CREAM NOVELTY CASE 1 VARIES VARIES VENDOR VENDOR GC 15.0 120 V 5 15P VENDOR PROVIDED STORAGE WIRE SHELVING S003 18"X 36" WIRE SHELVING UNIT UNIT INCLUDES (4) POSTS AND (4) SHELVES 16 EAGLE 1836VG/P74VG CK CK (4) SHELVES PER SECTION, (4) 72" POLES PER SECTION STORAGE WIRE SHELVING S007 24"X36" WIRE SHELVING UNIT UNIT INCLUDES (4) POSTS AND (4) SHELVES 5 EAGLE 2436VG/P74VG CK CK (4) SHELVES PER SECTION, (4) 72" POLES PER SECTION STORAGE WIRE SHELVING S008 24"X48" WIRE SHELVING UNIT UNIT INCLUDES (4) POSTS AND (4) SHELVES 8 EAGLE 2448VG/P74VG CK CK (4) SHELVES PER SECTION, (4) 72" POLES PER SECTION STORAGE WALL SHELVING S101 18” X 36" WALL MOUNTED WIRE SHELVING KIT KIT INCLUDES (2) BRACKETS & (1) SHELF 4 EAGLE 1836VG/WBI8 VG CK CK KIT COMES WITH (2) WALL END BRACKETS AND (1) SHELF PER KIT;SECURE TO WALL WITH BLOCKING STORAGE S201 WIRE STORAGE SHELVING CASTER X ENTER (4) PER SHELF AS NEEDED 1 FORTIER FOR/C5PSB CK CK CASTER ONLY ORDER (4) PER SHELF SECTION AS NEEDED TRANSACTION/CHECKOUT POS T001 EPOS RADIANT PACKAGE 2 NCR XR7 CK VENDOR GC 8.0 120 V 5 15P IG DEDICATED CIRCUIT; INCLUDES POS UNIT, CASH DRAWER, SCANNER, RECIEPT PRINTER, AND ALL CABLES TRANSACTION/CHECKOUT POS T002 PINPAD PACKAGE X 2 VERIFONE MX915 CK VENDOR GC TRANSACTION/CHECKOUT T003 UPS FOR POS AND NETWORK RACK BOH 3 TRIPPLITE OMNIVS800 CK VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT POS T004 UPS FOR NETWORK SWITCH X 2 TRIPPLITE BC350 CK VENDOR GC 120 V 5 15P IG DEDICATED SINGLE OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL TRANSACTION/CHECKOUT POS T005 COIN CHANGER PACKAGE X 2 GLORY GLOBAL MS9003 CK VENDOR GC TRANSACTION/CHECKOUT POS T006 RECEIPT PRINTER 2 NCR P201F074:T88V CK VENDOR GC TRANSACTION/CHECKOUT POS T007 LIFT STATION X 2 VERIFONE LIFT CK VENDOR GC TRANSACTION/CHECKOUT POS T008 COUPON PRINTER X 2 OUTSITE NETWORK APL01001 CK VENDOR GC TRANSACTION/CHECKOUT POS T009 PINPAD STAND X 2 OUTSITE NETWORK APL0300RC CK VENDOR GC TRANSACTION/CHECKOUT POS T010 MASHGIN SELF CHECKOUT PACKAGE 2 MASHGIN KIOSK V2.7 CK VENDOR GC 8.0 120 V 5 15P IG DEDICATED OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL TRANSACTION/CHECKOUT POS T011 GLORY SELF CHECKOUT CASH SYSTEM 2 GLOBAL GLORY CI 10 CK VENDOR GC 3.0 120 V 5 15P IG SHARE DEDICATED OUTLET WITH T010 UNIT TRANSACTION/CHECKOUT CHECKOUT MISC. T012 DNR 1 TYCO ELECTRONICS MS600596 CK VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT CHECKOUT MISC. T101 SMART SAFE VAULT + TUBE VEND 1 TIDEL SERIES 4 CK VENDOR GC 8.0 120 V 5 15P IG DEDICATED DUPLEX OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL TRANSACTION/CHECKOUT CHECKOUT MISC. T102 MONEY ORDER 2 HYPERCOM T7E CK VENDOR GC 3.0 120 V 5 15P IG QUADRUPLEX OUTLET WIRED THROUGH SURGE MANGEMENT PANEL TRANSACTION/CHECKOUT CHECKOUT MISC. T104 24 TICKET LOTTERY DISPLAY X 2 SCHAFER SYSTEMS 24 TMBL CK CK TRANSACTION/CHECKOUT CHECKOUT MISC. T105 36 GAME UNDERCOUNTER DISPENSER X 1 SCHAFER SYSTEMS 35/36 RHDT CK CK 120 V TRANSACTION/CHECKOUT CHECKOUT MISC. T106 LOTTO VERIFIER & PRINTER 1 VARIES VARIES VENDOR VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT CHECKOUT MISC. T107 CIG. BACK BAR 7 AMERICAN DISPLAY CUSTOM CK VENDOR GC 120 V 5 15P TRANSACTION/CHECKOUT CHECKOUT MISC. T108 LIQUOR BACK BAR OPTIONAL 1 ROYSTON CUSTOM CK VENDOR GC 120 V 5 15P TRANSACTION/CHECKOUT CHECKOUT MISC. T109 DOUBLE ACTING SWING GATE W/ POST 38" OPENING 1 ROYSTON CUSTOM CK CK TRANSACTION/CHECKOUT BO T201 BACK OFFICE COMPUTER, PRINTER, HANDHELD, AND ACCESSORIES 1 VARIOUS VARIES CK VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT BO T202 UPS FOR BO PC X 1 TRIPPLITE INTRNT OFFC 500R CK VENDOR GC 120 V 5 15P IG DEDICATED SINGLE OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL TRANSACTION/CHECKOUT FUEL/CREDIT T301 BACK RACK ACCESSORIES X 1 VARIOUS VARIES CK VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT FUEL/CREDIT T302 SITE CONTROLLER X 1 HP HP705 CK VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT FUEL/CREDIT T303 CREDIT CONTROLLER X 1 NCR EPC4 CK VENDOR GC 120 V 5 15P IG TRANSACTION/CHECKOUT FUEL/CREDIT T304 TIGER/PANTHER BOX X 1 PANTHER 32FP WEC7 CK PETRO GC 120 V 5 15P IG VARIOUS AND CONSTRUCTION ELECTRICAL/LV V001 ELECTRICAL PANEL SYSTEM 1 CPI/P.I. CUSTOM CK GC GC POWER INTEGRITY OR EQUIVALENT | SHOP DRAWINGS WILL BE PROVIDED WHEN NEW PANEL SYSTEM BEING USED VARIOUS AND CONSTRUCTION ELECTRICAL/LV V002 DSL BOX/FRAME RELAY X 1 VARIES CK VENDOR SUPPLIED BY CK, INSTALLED BY NETWORK INSTALLER VARIOUS AND CONSTRUCTION ELECTRICAL/LV V003 D MARC BOX X 1 VARIES VENDOR VENDOR GC SUPPLIED AND INSTALLED BY LOCAL PHONE COMPANY, COORDINATE WITH CIRCLE K CM FOR CONTACT. GC TO INSTALL GROUNDING LOCATION FOR D MARC VARIOUS AND CONSTRUCTION ELECTRICAL/LV V004 DOOR CHIME SYSTEM X 4 OPTEX RC 20U CK VENDOR GC 1.5 120 V 5 15P VARIOUS AND CONSTRUCTION ELECTRICAL/LV V005 SECURITY SYSTEM INSTALLED X INCLUDES DVR AND ALL HARDWARE 1 CBE CBE CK VENDOR GC 120 V 5 15P IG VARIOUS AND CONSTRUCTION ELECTRICAL/LV V006 NETWORK INSTALLED X INCLUDES ALL WIRING AND SWITCHES 1 CBE CBE CK VENDOR GC 120 V 5 15P IG VARIOUS AND CONSTRUCTION ELECTRICAL/LV V007 MUSIC SYSTEM INSTALLED X 1 ONKYO TX 8220 CK VENDOR GC 5.0 115 V 5 15P WILL NEED (1) QUAD OUTLET FROM PM PANEL FOR SYSTEM AND AMPLIFIER VARIOUS AND CONSTRUCTION ELECTRICAL/LV V008 LANDSCAPE CONTROLLER X 1 VARIES VARIES GC GC GC 120 V 5 15P INCLUDES ALL DECOR AND SIGNAGE NEEDED FOR BEVERAGE CAVES INCLUDING COLD VAULT WALL COVERING VARIOUS AND CONSTRUCTION FIXTURE/FURNITURE V101 METAL CABINETS 1 ROYSTON SEE SHOPS CK VENDOR PAINTED METAL CABINETS WITH LAMINATE ON DOORS AND SOLID SURFACE COUNTERTOP REFER TO SHOP DRAWING AND/OR DETAILS FOR COLOR SPECS VARIOUS AND CONSTRUCTION FIXTURE/FURNITURE V103 EXTERIOR FIRE EXINGUISHER ENCLOSURE X FORECOURT 7 CATO OR EQUAL CA 105 10 RRC H GC GC 5 OR 10LB DEPENDS ON AHJ VARIOUS AND CONSTRUCTION FIXTURE/FURNITURE V105 INTERIOR TRASH CAN X 2 ROYSTON CUSTOM CK CK VARIOUS AND CONSTRUCTION CONST. MATS. V201 FIRE EXTINGUISHER 2 KIDDE OR EQUAL 2A 10B C GC GC 5 OR 10LB DEPENDS ON AHJ VARIOUS AND CONSTRUCTION CONST. MATS. V202 INTERIOR LIGHTING X 1 FSG/RLA CREE CK GC GC VARIOUS AND CONSTRUCTION CONST. MATS. V203 EXTERIOR SITE LIGHTING X 1 FSG/RLA CREE CK GC GC VARIOUS AND CONSTRUCTION CONST. MATS. V204 CANOPY LIGHTING X 1 FSG/RLA CREE CK CANOPY PETRO VARIOUS AND CONSTRUCTION CONST. MATS. V205 CONDENSER RACKS (ALL) COOLERS, ICE & REMOTE CASES 1 PRECISION ALU. CUSTOM GC GC CONTACT PRECISION ALUMINIUM PRODUCTS, WWW.ACSTANDS.COM, (954) 480 6919 VARIOUS AND CONSTRUCTION CONST. MATS. V207 36" AIR CURTAIN OPTIONAL 2 MARS AIR STD236 1U CK GC GC 6.4 115 V 1 X VERIFY LOADS WITH MECHANICAL SCHEDULES VARIOUS AND CONSTRUCTION CONST. MATS. V208 60" AIR CURTAIN OPTIONAL 1 MARS AIR STD260 2U CK GC GC 12.75 115 V 1 X VERIFY LOADS WITH MECHANICAL SCHEDULES VARIOUS AND CONSTRUCTION CONST. MATS. V212 NICHIHA PANEL SYSTEM PACKAGE 1 NICHIHA CUSTOM CK GC CK TO ORDER VARIOUS AND CONSTRUCTION CONST. MATS. V213 INTERIOR TILE PACKAGE 1 DALTILE CUSTOM CK GC TILE PACKAGE INCLUDES RONDEC SCHLUTER, QUADEC SCHLUTER, ALL TILE, THINSET AND GROUTING MATERIALS VARIOUS AND CONSTRUCTION V501 OXBLUE CONSTRUCTION CAMERA X 1 OXBLUE CUSTOM CK GC GC 120 V 5 15P GC TO PROVIDE POLE AND TEMP POWER FOR EXTERIOR CAMERA AND TEMP POWER FOR INTERIOR CAMERA FOR THE DURATION OF CONSTRUCTION MARKETING FIXTURES EXTERIOR EQUIPMENT Z001 WATER PODS X 5 FOLLETT DB650SA CK OPS 10' 6" B.O. CANOPY A A B B 1 1 2 2 26' 8 1/2" 9' 0"9' 0" HEADER 10' 6" 10' 6" 8' 0"7' 8" ACT 4 ACT 3 CB1CB1 PREFAB WALK IN FREEZER 106 COLD VAULT 105 STORAGE ROOM 103 WALK IN COOLER 104 PREP AREA 110 CASHIER 108 SALES FLOOR 107 HALLWAY 111 MEN'S RESTROOM 102 10' 8" (T O F A C E O F S I P ) 46 ' 0 " 1' 3 " CB1 (TO FACE OF SIP) 113' 0" (TO FACE OF SIP) 113' 0" A9.2 10 7 A9.2 ______9 A9.2 ______ 5 A9.2 ______ 5 A9.2 ______ 5 A9.2 ______ A9.2 11 C 5 C 4 C 18 C 16 C 10C 10 C 10C 10 C 10C 10 C 19 C 12 C 22 C 20 C 12 C 15C 15C 15 C 5 C 21 C 14 C 13 C 13 C 9 C 9 C 9 CB1 10' 10" ? 2' 6 " 8 A9.2 ______ 10' 6" 2' 8 1 / 2 " ACT 1 10' 0" PREFAB C 14 8 21 C 14 9 7 A9.2 ______ 10' 8" C 20 C 10C 10 (T O F A C E O F S I P ) 46 ' 0 " 3 CB11 C 2 C 8 P3 P3 P3 C 10C 1016 14 13 2 C 8 15 CB1 P3 C 8 P2 7' 9" ℄OF SOFFIT ℄ C 14 10' 10" EXTERIOR ROOF ACCESS LADDER C 19 P2 P2 ACT 4 ACT 4 ACT 4 ACT 4 1' 9" EQ EQ 1' 3 " 10' 6" 10' 10" 10' 10" 10' 10"10' 10"10' 10" C 17 C 17 C 20 C 17 ACT 1 C 17 10' 8" C 17 C 17 C 19 C 17 C 17 C 15 C 15 C 10C 10 C 17 10' 10" C 10C 10 2 A8.1 ______ 9 A9.2 ______ 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" EQ EQC 7 C 9 C 5 C 6C 23C 23 CB1 P2 12' 2" B.O. CANOPY (PAINT TOASTY) C 16 ACT 1 10' 8" 7 2' 10" 1' 1 " 1 ' 1 " 2' 10" ACT 1 C 20 3 A1.6 ______ 3 A1.6 ______ SIM. C 24 C 24 C 24 17 ' 6 1 / 2 " 10' 10" 8 A9.2 ______ CB1 6 C 9 C 9 C 9 C 1 C 9 10 C 4 5 11 4 12 2' 2 " EQ EQ EQ E Q E Q E Q EQ. 4' 10 1/2" EQ. EQ. 4' 10 1/2" EQ. C 20 C 17 C 11 C 11 C 11 C 11 3' 2 1 / 2 " C 14PREFAB 1' 9" C 2 C 2 WOMEN'S RESTROOM 101 C 15 C 6 EQ E Q EQ BACK ROOM 109 ACT 1 8" STARTING TILE EMERGENCY BATTERY BACKUP LIGHT FIXTURE CAMERA LOCATION SUPPLY AIR DIFFUSER EXHAUST FAN CEILING ELECT. OUTLET ILLUMINATED EXIT SIGN2' CEILING TYPE CEILING HEIGHT SUSPENDED GRID, REFER TO ROOM FINISH SCHEDULE SHEET A1.2 2' 5/8" GYP. BD. CLNG. 2 X 4 LED LIGHT FIXTURE (PARABOLIC) 2 X 4 N.I. & EMERG. LED LIGHT FIXTURE XX MOISTURE PROOF FIXTURE SUPPLIED BY COOLER MFR. RECESSED OR SUSPENDED CAN LIGHT FIXTURE EXTERIOR WALL MOUNT LIGHT FIXTURE LED TRANSFORMER FOR INTERIOR SIGNAGE ABOVE CEILING LED x 2 x 2 LED LIGHT FIXTURE 2 x 2 N.L. & EMERG. LED LIGHT FIXTURE EMERGENCY RECESSED OR SUSPENDED CAN LIGHT FIXTURE EXTERIOR EMERGENCY WALL MOUNT LIGHT FIXTURE RETURN AIR GRILLE EMERG. MOISTURE PROOF FIXTURE SUPPLIED BY COOLER MFR. SURFACE FIXTURE SUPPLIED BY CIRCLE K/ INSTALLED BY GC 10 5 / 8 " 2 3 / 4 " LOPRO TRANSOM MOUNTING BRACKET (PART NUMBER J0041) BY MFR W/ (3) #12 HEX HEAD TEK SCREWS INTO STOREFRONT MULLION PROVIDE COMBINATION SIDE EXTENSION PLATES AS REQUIRED (B0020) (2) 3/8" BOLT , WASHER & NUT TO BRACKET IN PREDRILLED HOLE LOCATIONS @ EA. END OF HOUSING AIR CURTAIN, CENTER OVER OPENING. SEE MECH. MAX WEIGHT #150LBS STOREFRONT MULLION (20GA MIN) STOREFRONT DOOR SPANDREL GLASS WHEN WE HAVE AIR CURTAIN 1. SEE FINISH SCHEDULE ON SHEET A1.11 FOR FINISHES 2. DIMENSIONS FOR LIGHT FIXTURE LOCATIONS ARE TO CENTERLINE OF FIXTURE UNLESS OTHERWISE NOTED. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.6 PROJECT NUMBER: 24212 REFLECTED CEILING PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 NUMBER DESCRIPTION C 1 ROOF ACCESS LADDER, SEE DET. 7/A8.3 C 2 NICHIHA FIBER CEMENT WALL PANEL SYSTEM. COLOR TO MATCH SW 6095 TOASTY C 4 GYP. BOARD VALANCE ABOVE COOLER, FINISH SAME AS ADJACENT WALL. SEE DET. 5/A9.2. C 5 SOFFIT LINE. SEE DETAILS 9/A9.2 C 6 CONT. FRY REGLET VENT DCS 625 V 600. SEE DET. 2/A8.3 C 7 1' 8" X 2' 6" CEILING ACCESS DOOR PAINT TO MATCH SOFFIT, SEE DETAIL 2/A8.1 C 8 ILLUMINATED EMERGENCY EXIT SIGN. SEE ELECTRICAL C 9 EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS AND EXTERIOR ELEVATIONS C 10 SUSPENDED CEILING SYSTEM. SEE DETAILS 10/A9.2 & 11/A9.2. C 11 EMERGENCY BATTERY BACKUP LIGHT. SEE ELECTRICAL. C 12 24"x24" ACCESS PANEL ABOVE COOLER DOOR. C 13 MECHANICAL TOP UNIT ABOVE ROOF SHOWN FOR REFERENCE ONLY, SEE MECHANICAL AND ROOF PLAN C 14 EVAPORATORS, SEE MECH. C 15 EQUIPMENT BELOW, SHOW FOR REFERENCE ONLY. C 16 RECESSED LIGHT, SEE ELECT. C 17 LED LIGHT FIXTURE, SEE ELECT. C 18 GC TO COORDINATE WITH DECOR VENDOR FOR THE COFFEE WALL LIGHTING. C 19 LINE OF STORAGE LOFT SHELF, SEE DETAIL 4/A9.2 C 20 SURFACE LIGHT, SEE ELECT C 21 PIPE CHASE C 22 WALL MOUNTED SOFFIT SYSTEM BY BRAND VENDOR C 23 EXTERIOR EMERGENCY LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS AND EXTERIOR ELEVATIONS C 24 LINE OF MATERIAL CHANGE 3/16" = 1' 0" 1REFLECTED CEILING PLAN GENERAL NOTES 1 1/2" = 1' 0" 3AIR CURTAIN SECTION AT STOREFRONT TYPE DESCRIPTION ACT 1 SUSPENDED 2'x2' GRID WITH 1/2" THK WASHABLE LAY IN VINYL CLAD SHEET ROCK TILE (WHITE) ACT 2 NOT USED ACT 3 SUSPENDED 2'x2' GRID WITH 1/2" THK WASHABLE LAY IN VINYL CLAD SHEET ROCK TILE (ORANGE) ACT 4 SUSPENDED 2'X2' GRID WITH FINE FISSURED (WHITE) 2X2 LAY IN ACOUSTICAL CEILING TILES. SEE PAINT SPECS ON SHEET A1.11 CB1 5/8" GYP. CEILING BOARD, SEE PAINT SPECS ON SHEET A1.11 PREFAB PREFABRICATED INSULATED COOLER PANELS BY COOLER/FREEZER MANUFACTURER LEGEND N.T.S. 2NOT USED KEYNOTES CEILING TYPES A A B B 1 1 2 2 (TO FACE OF SIP) 113' 0" (TO FACE OF SIP ) 113' 0" SINGLE PLY SYSTEM: TPO (THERMOPLASTIC POLYOLEFIN MEMBRANE) ROOFING SYSTEM OVER RIGID INSULATION, WHITE MECHANICALLY FASTENED. SOLAR REFLECTANCE: .77 THERMAL EMITTANCE: .87 3' 0 " (T O F A C E O F S I P ) 46 ' 0 " TYP. D 15 11' 2" D 27WALK IN FREEZER CONDENSING WALK IN COOLER CONDENSING COLD VAULT CONDENSING D 2D 2 D 10 D 9 D 12 D 18 D 7 D 17 D 8 D 6 D 10 D 18 D 9 D 9 ICE MACHINE CONDENSING ISLAND SANDWICH CASE CONDENSING 3 A8.3 ______ 3 A8.1 ______ 3 A8.1 ______ 3 A8.1 ______ 5 A8.3 ______3 A8.3 ______3 A8.1 ______ 7' 3 1/2" 31' 9 5/8" D 4 D 17 EXTERIOR ROOF ACCESS LADDER 3 A8.3 ______ T.O. PARAPET 18' 6" 19' 4" 3 A8.1 ______ 3 A8.3 ______ 4' 9 5 / 8 " 3 A8.1 ______ TYP. D 14 3 A8.3 ______ 3 A8.1 ______ 2' 6 " TYP. D 3 TYP. D 14 D 17 D 2D 2 (TO FACE OF SIP ) 46 ' 0 " TYP. D 14 T.O. TOWER 23' 0" 4 A8.3 ______ 11 A8.3 ______ ZERO ZONE FREEZER CONDENSING D 18 39' 1 1/8" 43' 7 3/4" 30' 3 1/8" ICE MACHINE CONDENSING ICE MACHINE CONDENSING 11 ' 8 " 50' 1" 17' 5" 44' 4" TYP. D 15 TYP. D 3 D 4 D 21 D 20D 20 D 24 D 20 TYP. D 20 1 A4.0 ______1 A4.0 ______ 3 A4.0 ______ 3 A4.0 ______ 4 A4.0 ______ 4 A4.0 ______ SL O P E 1 / 4 " / 1 ' 0 " SL O P E 1 / 4 " / 1 ' 0 " SL O P E 1 / 4 " / 1 ' 0 " T.O. TOWER 23' 0" T.O. ROOF PANEL 17' 3 3/4" T.O. ROOF PANEL 17' 4" 10' 2 5/8" 23' 10" S L O P E 1 /2 " / 1 ' 0 "SLOPE 1/2" / 1' 0" D 17 D 22 7' 3 1/2" 48' 10" 9' 0 1/2" T.O. PARAPET 18' 6" D 1 D 21 T.O. PARAPET 18' 6" T.O. PARAPET 18' 6" T.O. TOWER 21' 6" T.O. TOWER 21' 6" 4' 1 1 " 8' 9" T.O. PARAPET 18' 6" 22' 11 5/8" D 18 3' 10" 7' 8" T.O. TOWER 23' 0" T.O. PARAPET 18' 6" T.O. PARAPET 18' 6" T.O. TOWER 21' 6" T.O. TOWER 21' 6" D 3 D 3 D 16 D 16 D 16 D 26 1 / 4 " - 1 '- 0 M I N . S L O P E 1/4" -1'-0 MIN. SLOPE D 3 D 3D 16 1' 0"10"2' 0" 22' 10" 22' 10" 2' 0" 10" 1' 0"A8.3 9 A8.3 12 3' 4 1 / 2 " 5' 4 " 11' 0 3/8" CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION SIP WALL PANELS REF. SIP VENDOR SHEETS ROOF DRAIN LEADER, SEE PLUMBING FOR SIZECONCRETE SLAB, REF. STRUCT NICHIHA CEMENT WALL PANEL WAINSCOT. INSTALL PER MFR. REQUIREMENTS WATER RESISTIVE BARRIER 1/2" EXPANSION MATERIAL SPLASH BLOCK PER ELEV.T.O. PARAPET CONTINUOUS 2X TREATED BLOCKING AS PART OF SIP WALL PANELS, SEE SIP VENDOR SHEETS SLOPE 3/4" PER FOOT PRE FINISHED METAL FASCIA, RE: EXT. ELEVATIONS SEALANT, TYP. TPO ROOFING TO CONTINUE UNDERNEATH OF METAL FASCIA AND RUNNING DOWN OVER PARAPET FRAMING. INSTALL PER MFR REQUIREMENTS. REFER TO SIP SHEETS FOR SPACING AND DETAILS. SIP ROOF PANEL SIP WALL PANEL 6 5/8" 10 " 2X6 SPF #2 OR BETTER AT 24" ON CENTER.REFER TO SIP DWGS. 7/16" OSB SHEATHING ATTACH W/ ANAILS. REFER TO SIP DWGS. PRE FABRICATED WOOD TRUSS @ 32' O.C. TPO ROOFING. INSTALL PER MFR REQUIREMENTS. REFER TO SIP SHEETS FOR SPACING AND DETAILS. CL L C CONDENSING UNIT, ATTACH TO CURB PER EQUIPMENT MANUFACTURER REQUIREMENTS/SPECIFICATIONS NOTE: PROVIDE STRAPS AS REQUIRED (2)2X4 WOOD NAILERS. SEE STRL. 4X4 PRESSURE TREATED WOOD SLEEPER WRAP WITH TPO SIP ROOF PANEL SYSTEM FRAMING AROUND PERIMETER OPENING. SEE SIP SHEETS VARIES SEE MECH 1. SEE DETAIL 8/A8.3 FOR FLASHING AT PIPE PENETRATIONS. 2. SEE BUILDING ELEVATIONS FOR PARAPET HEIGHTS. SINGLE PLY ROOFING SPECIFICATION ELEVATE TPO 60MIL (THERMOPLASTIC POLYOLEFIN MEMBRANE) MECHANICALLY FASTENED TPO WHITE ASTM D6878 CLASSIFICATION: UL CLASS: A FM CLASS: 1 45 PSF DESIGN MAX. SLOPE 1" DECK: COMBUSTIBLE INSULATION: 8 3/8" ROOF SIP PANEL W/ RIGID INSULATION. R VALUE R 33 TAPERED INSULATION: FACTORY TAPERED BOARDS FABRICATED TO PRODUCE SLOPE OF 1/4" PER FOOT. SLOPE TOWARDS DRAIN. CRICKETS: PROVIDE CRICKETS TAPERED. EDGE STRIPS WHERE INDICATED. AUXILIARY MATERIALS SHEET FLASHING: SAME SHEET AS FIELD SHEET BONDING ADHESIVE: MANUFACTURERS STANDARD BONDING ADHESIVE METAL TERMINATION BARS: PRE DRILLED STAINLESS STEEL OR ALUMINUM BARS FASTENERS: FACTORY COATED STEEL FASTENERS AND METAL PLATES MEETING CORROSION RESISTANCE PROVISIONS OF FMG 4470 MISCELLANEOUS: PROVIDE POURABLE SEALER, PREFORMED CONES, PREFORMED INSIDE AND OUTSIDE CORNER FLASHING, T JOINT COVERS, TERMINATION REGLETS, AND COVER STRIPS. WALK WAY PADS: FACTORY FORMED, NON POUROUS, HEAVY DUTY SLIP RESISTANT PADS OR ROLLS ACCEPTABLE TO MEMBRANE ROOFING SYSTEM MANUFACTURER. ROOF ASSEMBLY SHALL BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. PROVIDE PATCH OVER ALL 'T' LAP JOINTS IN THE ROOF. ROOFING WARRANTY FULL SYSTEM WARRANTY +/ 20 YEAR LIMITED WARRANTY COVERING MEMBRANE AND MEMBRANE ACCESSORIES. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.7 PROJECT NUMBER: 24212 ROOF PLAN AND DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 KEYNOTES GENERAL NOTES SINGLE PLY ROOFING SPECIFICATION 3/16" = 1' 0" 1ROOF PLAN 1" = 1' 0" 2ROOF DRAIN LEADER 1" = 1' 0" 3PARAPET BRACING DETAIL 1" = 1' 0" 4SLEEPER DETAIL CONDENSERS NUMBER DESCRIPTION D 1 METAL ROOF ACCESS LADDER WITH SECURITY DOOR BELOW. SEE DETAIL 7/A8.3 D 2 TPO (THERMOPLASTIC POLYOLEFIN MEMBRANE) ROOFING SYSTEM OVER SIP ROOF PANEL, WHITE MECHANICALLY FASTENED D 3 TAPERED DRAINAGE VALLEY CRICKET, MINIMUM SLOPE 1/4" PER. FOOT. SEE DETAIL 4/A8.3 D 4 ROOF TOP HVAC UNIT, SEE MECHANICAL AND SIP. DRAWINGS. D 6 COLD VAULT CONDENSING UNIT, SEE MECHANICAL DRAWINGS. D 7 WALK IN FREEZER CONDENSING UNIT, SEE MECHANICAL DRAWINGS. D 8 WALK IN COOLER CONDENSING UNIT, SEE MECHANICAL DRAWINGS D 9 ICE MACHINE CONDENSING UNIT (ITEM 16A), SEE MECHANICAL DRAWINGS D 10 4"x4" PRE TREATED WOOD SLEEPER CONDENSER SUPPORT WITH PROTECTION PAD. PROVIDE EQUIPMENT STRAPS TO SECURE CONDENSERS TO SLEEPERS, SEE DETAIL 4/A1.7 D 12 ISLAND SANDWICH CASE CONDENSING UNIT. SEE MECHANICAL. D 14 PRE FINISHED GALVANIZED METAL FASCIA, SEE EXTERIOR ELEVATIONS AND DETAIL 3/A8.3 D 15 30" WIDE WALKING PATH FOR EQUIPMENT ACCESS. "ULTRA PLY TPO" WALKWAY PAD BY FIRESTONE OR EQUAL. INSTALL PER MANUFACTURER INSTRUCTIONS. VERIFY PATH LOCATION WITH CIRCLE K PROJECT MANAGER. D 16 PARAPET BRACING AS REQUIRED, SEE DETAIL 3/A1.7 AND SIP VENDOR SHEETS. D 17 ROOF JACK FOR REFRIGERANT LINE, SEE DETAIL 2/M1.2.1, MECHANICAL AND ELECTRICAL D 18 VTR LOCATION, SEE PLUMBING DRAWINGS. D 20 PRE FAB WOOD TRUSSES, SEE SIP SHEETS. D 21 TPO ROOF AT PARAPET TYP. SEE DETAIL 3/A8.3 & 10/A8.3 D 22 FREEZELESS ROOF HYDRANT, SEE PLUMBING DRAWINGS D 24 ZERO ZONE FREEZER CONDENSING UNIT D 26 DRAFT STOP, SEE DETAIL 1/A8.3 D 27 SATELLITE DISH FOR LOTTERY MACHINE. GC TO COORDINATE WITH CK CONSTRUCTION MANAGER FOR FINAL LOCATION A A B B 1 1 2 2 WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 HALLWAY 111 MEN'S RESTROOM 102 SALES FLOOR 107 PREP AREA 110 CASHIER 108 BACK ROOM 109 WALK IN COOLER 104 14 ' 1 " FCO FCO 8' 11" F 03 19' 5" 2' 9" EXTERIOR ROOF ACCESS LADDER CL CL CL CL CL CL F 03 F 01 F 01 F 01 F 01 F 03 2' 2 " CL 11' 3" CL 40' 0" CL 15 ' 2 " 41' 4" F 03 9' 9" CL F 03 4' 3 " 9' 8" F 08 41' 8"CL CL A1.8 4 A1.8 5 A1.8 6 A1.8 7A1.8 3 F 04 TYP. F 06 41' 10" 4' 3 " F 02 44' 9" 2' 5 " F 02 48' 0" 55' 5" 62' 11" 8' 1 1 " 6' 2 " TYP. F 01 CL CL CL CL F 06 F 06 TYP. F 06 TYP. F 06 TYP. F 06 TYP. F 06 WOMEN'S RESTROOM 101 TYP. F 06 TYP. F 06 F 02 F 02CL CL SL O P E SL O P E SLOPE SLOPE SLOPESLOPE SL O P E SL O P E F 08 11 ' 0 " 16' 0" 5' 6" 29 ' 1 " CL CL CL CL CL 14 ' 2 " 24' 5" CL 26 ' 8 " 49' 9"CL56' 3" 40' 3" CL 13 ' 3 1 / 4 " 28' 6 1/4"CL CL TYP. F 05 9' 5 " 6 ' 1 0 " 8 ' 6 " FCO CL CL CL CL CL CL CL CL CL CL CL CL 10 ' 7 " 9 ' 1 " 9 ' 2 " 2' 2 7/8" 1' 11 1/4" 19 ' 8 " 20' 2 7/8" 20' 3 1/4" F 03F 09 TYP. F 06 TYP. F 06 TYP. F 06 F 07 15' 6"CL 1' 2 " CL F 03 F 03 CL A3.1 1 5/8" GYP. BD. ON 3 5/8" 20 GA. METAL STUDS AT 16" O.C. (SEE FINISH SCHEDULE AND WALL TYPES) REFRIGERANT LINE SEE MECHANICAL 4" CONDUIT SLEEVE PIPE CUT FLUSH WITH TOP OF CONRETE SLAB NOTE: MECHANICAL CONTRACTOR SHALL INSTALL A 4" DIAMETER PVC PIPE, SCHEDULE 40, FROM TOP OF SLAB, DOWN BELOW SLAB, OVER TO DELI CASE AND TERMINATE AT SLAB WITH PULL STRING AS SHOWN. THE REFRIGERANT PIPING WILL BE INSTALLED IN THIS PIPE SLEEVE. CONTRACTOR SHALL PROVIDE LONG RADIUS TYPE SWEEP ELBOWS. MECHANICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR THE TIMING OF THIS INSTALLATION. PIPING SHALL BE CAPPED AT OPEN ENDS AS SOON AS IT IS INSTALLED TO PREVENT DIRT, DEBRIS, AND WATER FROM COLLECTING INSIDE OF PIPE. COORDINATE TERMINATION POINT AT SLAB WITH DELI CASE INSTALLATION INSTRUCTIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ELEVATION OF PIPE BELOW SLAB WITH PLUMBING UTILITIES. 4" CONCRETE SLAB ON GRADE OVER VAPOR BARRIER, OVER 4" AGGREGATE BASE. SEE STRUCTURE ℄ 1. VERIFY ALL SLAB PENETRATION LOCATIONS WITH CIRCLE K PROJECT MANAGER AND EQUIPMENT 2. CONTRACTOR SHALL ADEQUATELY SEAL ALL FLOOR, WALL AND ROOF PENETRATIONS. TYP. F 06 TYP. F 06 TYP. F 06 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L GC TO REFER TO MANUFACTURER SUBMITTAL FOR FINAL STUB UP DETAIL 2' 0 " 3 ' 1 1 " 3 ' 1 1 " 3 ' 1 1 " 13 ' 9 " F 04 1' 3" 9" VE E D E R RO O T F 03 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.8 PROJECT NUMBER: 24212 FLOOR PENETRATION PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3/16" = 1' 0" 1FLOOR PENETRATION PLAN 1" = 1' 0" 2DELI ISLAND CONDUIT DETAIL NUMBER DESCRIPTION F 01 CONCRETE SLAB, SEE STRUCTURAL FOR REINFORCING F 02 FLOOR DRAINS, SEE PLUMBING DRAWINGS F 03 FLOOR SINK, SEE PLUMBING DRAWINGS F 04 4" CONC. CURB AT ELECTRICAL PANELS F 05 DOMESTIC WATER POINT OF ENTRY, REF. SHEET P1.1.2 F 06 CONDUIT STUB, SEE ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION. F 07 CONDUIT & SLEEVE PIPE UNDER SLAB FOR DELI ISLAND REFRIGERANT LINE, SLEEVE PIPE TO BE CUT FLUSH AND LEVEL WITH SLAB, SEE MECHANICAL DRAWINGS AND DETAIL 2/A1.8. F 08 HUB DRAINS, REF. SHEET P1.1.1 F 09 3" CONDENSATE LINE CHASE LARGE SWEEP KEY NOTES GENERAL NOTES 3/8" = 1' 0" 4ENLARGED AT CASHIER AREA 3/8" = 1' 0" 5ENLARGED AT HOTDOG AREA 3/8" = 1' 0" 6ENLARGED AT CONDIMENT AREA 3/8" = 1' 0" 7ENLARGED AT ELECTRICAL PANELS 3/8" = 1' 0" 3ENLARGED AT BEER TROUGH 1. VERIFY MUSIC & SPEAKERS LAYOUT WITH CIRCLE K REPRESENTATIVE 2. G.C. TO PULL ALL SPEAKER WIRE FOR STORE & CANOPY 1. SECURITY SYSTEM DESIGNED AND PROVIDED BY CIRCLE K 2. INDICATES APPROXIMATE CAMERA LOCATIONS 3. FINAL CAMERA LOCATIONS TO BE DETERMINED BY CIRCLE K X A A B B 1 1 2 2 WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 HALLWAY 111 MEN'S RESTROOM 102 WALK IN COOLER 104 BACK ROOM 109 SALES FLOOR 107 CASHIER 108 PREP AREA 110 1 2 3 9 8 21 EXTERIOR ROOF ACCESS LADDER 1314 1516 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L BC S BC S 4R V Z C 3 0 T 2 4 R V Z C 3 0 4R V Z C 3 0 4R V Z C 3 0 T 2 CO2 19 20 17 18 7 5 4 1110 12 6 WOMEN'S RESTROOM 101 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.9 PROJECT NUMBER: 24212 SECURITY SYSTEM FLOOR PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 GENERAL NOTES KEY NOTES 3/16" = 1' 0" 1SECURITY SYSTEM FLOOR PLAN (FOR REFERENCE ONLY)EXTERIOR ENVELOPE SEQUENCING MATRIX NOTE FOR GC: GC TO WORK WITH CK CM TO CLARIFY IF THE TPO SCOPE IS WITH GC OR PORTER CONDENSERS / RTU PROVIDED BY CK ● NON SIP BASED OVERHANGS/CANOPY ● ● PARAPET COPING ● ● ROOF PANEL TIE DOWNS ● ● TPO ROOFING ● ● TAPERED INSULATION ● ● CRICKETS / EDGE STRIPS ● ● GUTTERS/SCUPPERS/OVERFLOW ● ● ROOFTOP UNIT PENETRATIONS ● ● ROOFTOP UNIT CURBS ● ● PARAPET KICKER PANELS ● ● PARAPET RETURNS ● ● PARAPET (WHERE INDEPENDENT OF SIP WALL)● ● SIP BASED OVERHANGS/CANOPY ● ● ROOF PANELS ● ● ROOF FIBER CEMENT PANELS ● ● FIBER CEMENT PANEL CLIPS/SPACERS ● ● FIBER CEMENT PANEL FLASHING/ STARTER TRACK ● ● HORIZONTAL STARTER TRACK (UPSIDE DOWN...● ● KURASTONE VENEER PIECES UP TO SILL ● ● KURASTONE WAINSCOT SILL ● ● WAINSCOT STARTER FLASHING/CLIPS/SPACERS ● ● WALL FINISH AT EXTERIOR WOOD BLOCKING AT ROOFTOP PENETRATIONS ● ● GC TO COORD. WALL/ROOF FINISH FOR WEATHER TIGHT SEAL WOOD BLOCKING, UNO IN SIPS PLANS ● ● WOOD TRUSSES/BRACING ● ● EXCEPTION RTU/CONDENSER BLOCKING HANGERS PROVIDED & INSTALLED BY GC TRUSS HANGERS/CLIPS ● ● ROOF STRUCTURE WATER RESISTANT BARRIER AT WALLS ● ● ELECTRICAL INSTALL AT PRE DRILLED WIRE CHASE(S) GC TO COORD ELEC INSTALL W/SIP VENDOR INSTALLATION WOOD BLOCKING, UNO IN SIPS PLANS ● ● GLULAM/LVL HEADERS ● ● TOP PLATES, UNO IN SIPS PLANS ● ● TRANSITIONS/INTERSECTION/SPLINED TOGETHER ● ● PILASTERS ● ● SIPs LIFTED ONTO BASE ● ● SILL PLATE ANCHOR BOLTS & SIMPSON STHD 14 HOLD DOWN STRAPS ● ● ALL OTHER HOLD DOWNS PROVIDED & INSTALLED BY GC SILL SEALS ● ● WALLS FLOOR SLABS ● ● FOUNDATION FOOTINGS / STEM WALLS (IF ANY)● ● FOUNDATIONS GC SIP CONTRACTOR GC SIP CONTRACTOR MATERIAL/ELEMENT PROVIDED BY INSTALLED BY REMARKS A A B B 1 1 2 2 (T O F A C E O F S I P ) 46 ' 0 " (TO FACE OF SIP) 113' 0" (TO FACE OF SIP) 113' 0" WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 WALK IN COOLER 104 BACK ROOM 109 SALES FLOOR 107MEN'S RESTROOM 102 HALLWAY 111 PREP AREA 110 CASHIER 108 EXTERIOR ROOF ACCESS LADDER 3 A8.2 ______3 A8.2 ______ 1 A8.2 ______ G 02 G 03 G 03 G 01 G 01 G 08G 08 G 07 G 06G 06 G 06G 06 G 03 G 04 G 07 G 01 G 03 G 05 G 12 CS1 CS1 CS1 CS1 G 09 G 03 G 10 G 06G 06G 06 G 03 T1T1 G 06G 06G 06 T1 T1 (T O F A C E O F S I P ) 46 ' 0 " G 10 G 01 CO2 T1 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L 1 A8.2 ______ G 03 G 11 G 11 G 11 G 11G 11 G 03 G 11 G 11 G 11 G 11 G 11 G 03 PREFAB G 07 G 11 G 11 WOMEN'S RESTROOM 101 2' 0 " 2' 0" G 03 VE E D E R RO O T VE E D E R RO O T G 03 G 03 USE DETAIL 'A', FLOOR TILE TO METAL COVE SCHLUTER TO WALL TILE FOR RESTROOMS, HALLWAY AND SALES AREA. METAL COVE BASE SCHLUTER, SEE FINISH SCHEDULE FRP TILE, SEE FINISH SCHEDULE FLOOR TILE, SEE FINISH SCHEDULE 4" 24" X 24" PORCELAIN TILE FINISH. SEE TILE SPECS ON SHEET A1.11 EXPOSED SEALED CONCRETE, SEE SPECS ON SHEET A1.11 REFRIGERATED FLOOR PANEL AT WALK IN FREEZER . T1 CS1 PREFAB REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.10 PROJECT NUMBER: 24212 FLOOR FINISH PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3/16" = 1' 0" 1FLOOR FINISH PLAN 1 1/2" = 1' 0" ADETAIL 'A' METAL COVE BASE NOTE: SCHLUTER METAL COVE BASE FOR FLOOR TILE AND WALL TILE, SEE TR03 "INTERIOR FINISH" SPEC. ON SHEET A1.11 AND DETAIL A/A1.10 KEY NOTES FLOOR TYPES NUMBER DESCRIPTION G 01 ALUMINUM THRESHOLD G 02 START POINT OF TILE PATTERN G 03 FLOOR DRAIN AND FLOOR SINK, SEE PLUMBING DRAWINGS G 04 MOP SINK G 05 4" HIGH CONCRETE CURB FOR ELEC. PANELS & LOW VOLTAGE. G 06 WATERPROOFING MEMBRANE UNDER 9" AND UP TO WALL 9" G 07 PROVIDE SCHLUTER "RENO RAMP" FOR FLOOR TILE AND SEALED CONCRETE TERMINATION, SEE TR08 "INTERIOR FINISH" SPEC. ON SHEET A1.11 G 08 WALK IN FREEZER FLOORING BY FREEZER MANUFACTURER. G 09 IF NEEDED PROVIDE 4" CONCRETE HOUSEKEEPING PAD ABOVE SIDEWALK UNDER ELECTRICAL CABINET, COORDINATE SIZE AND LOCATION PAD AND CABINET WITH ELECTRICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION G 10 PROVIDE SOFT MOVEMENT JOINT LOCATION IN CERAMIC TILE FLOOR PER TCNA HANDBOOK DETAIL EJ171, EVERY 20 TO 25 FEET BOTH DIRECTIONS G 11 FLOOR OUTLET, SEE FLOOR PENETRATION PLAN SHEET A1.8 AND ELECTRICAL DRAWINGS. G 12 3" CONDENSATE LINE CHASE, SEE FLOOR PENETRATION PLAN SHEET A1.8 1. INTERIOR FINISHES & DRYWALL FINISHING LEVELS 2. WALL/CEILING BOARD FINISH LEVEL FINISH PANELS TO LEVELS INDICATED BELOW, ACCORDING TO ASTM C 840, FOR LOCATIONS INDICATED: LEVEL 1 CONCEALED AREAS : EMBED TAPE AT JOINTS IN CEILING PLENUM, BACK OF HOUSE AND OTHER CONCEALED AREAS UNLESS A HIGHER LEVEL OF FINISH IS REQUIRED FOR FIRE RESISTANCE RATED ASSEMBLIES AND SOUND RATED ASSEMBLIES. LEVEL 2 TILE SUBSTRATE: EMBED TAPE AND APPLY SEPARATE FIRST COAT OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES. LEVEL 3 WALLCOVERINGS AND TEXTURED FINISHES: EMBED TAPE AND APPLY SEPARATE FIRST AND FILL COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES. LEVEL 4 EXPOSED, PAINTED GYPSUM BOARD: EMBED TAPE AND APPLY SEPARATE FIRST, FILL, AND FINISH COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES WHERE FLAT PAINTS ARE INDICATED. LEVEL 5 EXPOSED, PAINTED GYPSUM BOARD: EMBED TAPE AND APPLY SEPARATE FIRST, FILL, AND FINISH COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES, AND APPLY SKIM COAT OF JOINT COMPOUND OVER ENTIRE SURFACE, WHERE EGGSHELL, SEMI GLOSS AND GLOSS PAINTS ARE INDICATED. 3. SEE SHEETS A3.1, A3.2 & A3.3 FOR INTERIOR ELEVATIONS. 4. SEE SHEET A1.6 FOR CEILING FINISH AND CEILING HEIGHTS. 5. SEE MILLWORK VENDOR FOR CABINET LAMINATE FINISH 6. SEE SHEET A1.10 FOR FLOOR FINISH A A B B 1 1 2 2 (T O F A C E O F S I P ) 46 ' 0 " (TO FACE OF SIP) 113' 0" (T O F A C E O F S I P ) 46 ' 0 " (TO FACE OF SIP) 113' 0" WALK IN FREEZER 106 STORAGE ROOM 103 COLD VAULT 105 WALK IN COOLER 104 BACK ROOM 109 SALES FLOOR 107 MEN'S RESTROOM 102 HALLWAY 111 PREP AREA 110 CASHIER 108 EXTERIOR ROOF ACCESS LADDER FRP2 TR 02 TR 03 TR 01 FRP3 TR 03 P1 B1 WB4 WB1 WB1 B2 FRP1 B1 WB1 B2 B2 P1 B1 P1 B1 WB1 DC1 WB1 FRP2 TR 03WB4 P4 WB1 TR 03 FRP2 DC1 WB1 TR 03 FRP2 B1 WB1 FRP1 B1 WB1 FRP1 FRP2 TR 02 WB4 FRP2 TR 02 WB4 FRP2 TR 02 TR 03 WB4 P1 FRP3 TR 03 WB4 WB4 P2 SOFFIT P3 SOFFIT CO2 EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L WB3 WB4 P2 SOFFIT FRP4 FRP4 FRP4 TR 03FRP4 TR 03 TR 01 P1 TR 01 P1 TR 01 P1 TR 01 P1 TR 01 P1 WOMEN'S RESTROOM 101 FRP2 TR 02 WB4 FRP4 P1 TR 01 TR 03 FRP2 TR 02 WB4FRP4 P1 TR 01 TR 03 VE E D E R RO O T P1 FRP2 TR 03 WB2 WB4 COOLER WALL STUD WALL ABOVE COOLER WB3 WB2 WB4 COOLER WALL STUD WALL ABOVE COOLER REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A1.11 PROJECT NUMBER: 24212 WALL FINISH PLAN AND FINISH SCHEDULE CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 GENERAL NOTES T1 DalTile 24"x24" Porcelain Slate Attache' Multi Brown Concrete Slab CK Floor Tile. Grout: G1, 3/16" Grout Line. Tile P7 RAL Powdercoat Gloss Silver Cloud Metal Cabinets N/A Provide on all cabinetry by manufacturer P6 RAL Powdercoat Gloss Black Metal Cabinets N/A Provide on some cabinetry & gondola by Manufacturer P5 Sherwin WIlliams Paint Semi Gloss SW7017 Dorian Gray Doors & Frames GC All interior doors and frames P4 Sherwin WIlliams Paint Eggshell SW6965 Hyper Blue WB1 GC Walls behind the fountain and Cold Beverage P3 Sherwin WIlliams Paint Eggshell SW6887 Navel WB1 GC CK Orange Walls and Soffits P2 Sherwin WIlliams Paint Flat SW7006 Extra White CB1 GC Hard Deck Ceilings P1 Sherwin WIlliams Paint Eggshell SW7006 Extra White WB1,WB2,WB3 GC Most Walls Paints ACT4 Varies 2'x2' Fine Fissured White Suspended GC 15/16" Suspension system with 2'x2' T Bar grid Prefinished White ACT3 Varies 2'x2' Vinyl Clad Sheetrock P3 Suspended GC 15/16" Suspension system with 2'x2' T Bar grid P3 ACT1 Varies 2'x2' Vinyl Clad Sheetrock White Suspended GC 15/16" Suspension system with 2'x2' T Bar grid Prefinished White Suspended Ceilings PLY1 Varies 5/8" Plywood GC WB4 Varies 5/8" CWB/SIP OSB LEVEL 2 See General Notes N/A Cooler Box/Rest GC 5/8" Cement wall board/SIP OSB Level 2 finish to accept tile. All other wall tile applications. WB3 Varies 1/2" CWB LEVEL 2 See General Notes N/A Cooler Box GC 1/4" Cement wall board Level 2 finish to accept tile. For Use on Cooler Walls. WB2 Varies 1/4" GWB LEVEL 3 See General Notes N/A To SIP GC 1/4" Gypsum Wall Board Level 3 Finish WB1 Varies 5/8" GWB LEVEL 3 See General Notes N/A To SIP/OSB GC 5/8" Gypsum Wall Board Level 3 Finish CB1 Varies 5/8" GCB LEVEL 4 See General Notes N/A To Studs GC 5/8" Gypsum Ceiling Board Level 4 Finish Substrates B3 DalTile Coved Tile Base 6X12 Tile Portfolio PF10 Cotto WB3 CK P36C9T. Use Cove Base inside and outside corners as needed. Grout: G1 B2 Everidge 4" Coved Metal Silver Embossed Cooler Box CK By Cooler/Freezer Vendor B1 Varies 4" Rubber Base N/A Black WB1, WB2 GC 4" High rubber base, use inside and outside corners as needed Base Key / Category Manufactuer Type Finish Color Substrate Provided By Description/Remarks INTERIOR FINISH MATERIALS SS 1 Wilsonart Solid Surface N/A Arctic Melange 9070ML Countertops CK Provide on all Cabinetry by Manufacturer PLAM1 Wilsonart Laminate 38 Finish Natural Rift 7954 38 Cabinetry N/A Provide on all Cabinetry by Manufacturer DC5 Décor Company Décor PVC Panel Blue Prism PREFAB CK Décor Panels By Décor Company DC4 Décor Company Décor PVC Panel Red Ribbed WB1 CK Décor Panels By Décor Company DC3 Décor Company Décor PVC Panel Orange Ribbed WB1 CK Décor Panels By Décor Company DC2 Décor Company Décor PVC Panel Blue Ribbed WB1 CK Décor Panels By Décor Company DC1 Décor Company Décor PVC Panel Red Sunrise WB1 CK Décor Panels By Décor Company FRP4 Marlite Symmetrix FRP Digital Tile Print 12"x24" Multi Brown WB4 CK Blue Sky Advance Finish, Marlite Aluminium Trim Molding FRP3 Marlite Symmetrix FRP Digital Tile Print Subway Orange WB3, WB4 CK Sani Coat FRP, marlite Aluminium Trim Molding FRP2 Marlite Symmetrix FRP Digital Tile Print Subway White WB3, WB4 CK Sani Coat FRP, marlite Aluminium Trim Molding FRP1 Marlite FRP Pebbled P 100 White or Equal PLY1 GC All Back Rooms Use all standard trim for panels. CS1 WR Meadows Concrete Sealer VoComp A20 Clear Concrete Slab GC Scrub & Seal Floors that are exposed concrete. Apply per mfg recommendation PREFAB Everidge Cooler Panel Aluminum Silver Embossed N/A CK Prefabricated insulated cooler box panels by manufacturer Misc. TR09 Varies 2X2 Outside Corner A560 Stainless Steel WB1 GC 2"X2" Outside Stainless Steel Corner Guards TR08 Schluter Reno Ramp AERP100B65 Satin Anodized Alum T1 GC Tile Installer to provide and install ramp for transition from Tile to Concrete TR07 Marlite Connectors Varies Satin Anodized Alum TR01, TR02, TR03 GC Any Connectors needed for Schluter to be provided by Installer TR06 Marlite Quadec In/Cnr A551 Satin Anodized Alum TR 02 CK Inside/Outside Corners to be used with inside corner trim TR03 Marlite EDGE A570 Satin Anodized Alum FRP2, FRP3 CK To be used where any floor tile meets wall tile. TR02 Marlite DIVSION A565 Satin Anodized Alum FRP4. FRP2 CK To be used to separate transition between T4 & T2; restrooms only. TR01 Marlite EDGE A570 Satin Anodized Alum FRP2, FRP3 CK To be used on all outside corner, and to cap/terminate Subway tile. Trims G1 Mapei Ultracolor Plus FA 3/16" Grout Line #10 Black T1 CK For Use with All Slate Attache' Tile Grouts Key / Category Manufactuer Type Finish Color Substrate Provided By Description/Remarks INTERIOR FINISH MATERIALS 3/16" = 1' 0" 1WALL FINISH PLAN FINISH FLOOR +0" A B3 A4.0 ______4 A4.0 ______ +8"+18" +18"0"+18" +18" +8" 0"0" +36" E. J . E. J . +10"+2" +2" +2" +2" +10" E. J . E. J . 12 A8.2 ______1 6 STARTER PANEL 1 STARTER PANEL 12 STARTER TRACK AT 3" TYPICAL T.O. WAINSCOT CAP+3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" B A H J A B BAHH B C C CB FGG JIE C D B C H F F B B E 8 E 7 E 17 E 11E 11 E 8 E 30 E 14 E 8E 3 E 5 TYP. E 15 TYP. E 24 E 22E 3 TYP. E 16E 34 E 8E 8 E 30E 5E 8 E 35 E 35 E 8 E 2 E 30 E 7 E 2 E 17 E 8 TYP. E 15 TYP. E 16 E 3 TYP. E 24 TYP. E 16 E 8 E 25 TYP. E 24 T.O. TOWER +23' 0" 3 A8.1 ______ 3 A8.1 ______ 3 A8.1 ______ 9 A8.1 ______ 8 A8.1 ______8 A8.1 ______ 9 A8.1 ______6 A8.1 ______ 6 A8.2 ______ 3 A8.3 ______ 1 A6.1 ______ 4 A6.1 ______ 3 A6.1 ______ 2 A6.1 ______ E 8 E 8E 8 E 11 E 8E 8E 8 E 4 E 4 E 4 E 7 E 37 E 37 E 37 E 15 G E 19 E 15 G FINISH FLOOR +0" AB 3 A4.0 ______4 A4.0 ______ +8"0"0"+8" 0"+8" 0"+8" 3 A8.1 ______ 3 A8.3 ______3 A8.1 ______ 5 A9.3 ______8 A8.1 ______8 A8.1 ______ 9 A8.1 ______ GF AH FG TYP. 0" TYP. 6 A9.3 ______ H B B A HBB +10" +2" +2" +10"+2"+8"+2"+2"+2" STARTER TRACK AT 3" TYPICAL +8" E. J . E. J . 12 A8.3 ______9 A8.3 ______ 4 A9.3 ______ 1 A9.3 ______1 A9.3 ______ T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" B.O. LIGHT FIXTURE +14' 6" A H E. J . A H A H AHH G FG GF 5 A8.1 ______5 A8.1 ______ 5 A8.1 ______ E 13 E 13 TYP. E 24 E 18 E 8 E 8 E 11 E 10 E 11 E 11E 11 E 7 E 29 E 9E 30 E 8 E 9 E 30 E 9 E 30E 8 E 8 E 8 E 7 E 8E 7E 7 E 8 E 8 E 7 E 15 E 16 E 16 E 15 TYP. E 24E 15 E 16 E 15 TYP. E 24E 16 T.O. TOWER +23' 0"E 36 H E 36 H E 15 E 37 FINISH FLOOR +0" 1 2 1 A4.0 ______ +8" 0" +8"0" 96" 362" +10" 3 A8.1 ______ 6 A9.3 ______ 5 A9.3 ______ 3 A8.3 ______ 8 A8.1 ______ 9 A8.1 ______ B AH B H A BGFAA +2"+10" A 0" H TYP. STARTER TRACK AT 3" TYPICAL ALIGN THE NICHIHA PANEL WITH THE DOOR OPENING 2" T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" T.O. PARAPET +18' 6" B.O. LIGHT FIXTURE +14' 6" EQ EQ A G EQ EQ E 8 E 31 E 8 E 33E 9 TYP. E 24E 8E 10E 25 E 11E 11E 12 E 9 E 8 E 15 E 26 E 7 E 7 E 8 E 8 E 37 E 16 E 15 TYP. E 24 T.O. TOWER +23' 0" E 29E 6 E 23 E 37 H FINISH FLOOR +0" 12 1 A4.0 ______ +8"0" 0"+8" 96" 468" 3 A8.3 ______ 9 A8.1 ______ 8 A8.1 ______ 6 A9.3 ______ 5 A9.3 ______ +10"+2" +2"+10" TYP. ALIGN THE NICHIHA PANEL WITH THE DOOR OPENING T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" T.O. PARAPET +18' 6" B.O. LIGHT FIXTURE +14' 6" B H A HH A G F A H AG HH A EQ EQ EQ EQ G 5 A9.3 ______ 6 A9.3 ______ E 8 E 31E 8 E 33E 9 TYP. E 24 E 8 E 11E 11 E 37E 12E 9 E 8 E 15E 26 E 7 E 7E 8E 37 E 16E 15E 42E 43 TYP. E 24 T.O. TOWER +23' 0" E 15 ***NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6095 TOASTY ***NICHIHA TUFF BLOCK COLOR TO MATCH #SW 6115 TOTALLY TAN 1" INSULATED, DOUBLE PANED GRAY TINTED GLASS *SHERWIN WILLIAMS #SW 4081 **SAFETY RED *SHERWIN WILLIAMS #SW 7005 CIRCLE K WHITE ***NICHIHA CHISELED SILL TAN ***NICHIHA LEDGESTONE BLUFF *SHERWIN WILLIAMS #SW 6090 JAVA FIRESTONE MANSARD BROWN SR (USE FOR PRE FINISHED METAL FASCIA) CIRCLE K ORANGE #PMS 144 *** NICHIHA TUFF BLOCK COLOR TO MATCH #SW 4081 * USE SHERWIN WILLIAMS MANUFACTURER ONLY ** COLOR TO BE PRE ORDERED TO ENSURE AVAILABILITY AT TIME OF CONSTRUCTION ***TO BE PURCHASED BY CIRCLE K/INSTALLED BY G.C. G.C. TO COORDINATE WITH CK PM AND OWNER'S REP circlek@nichiha.com J A B C D E F G H I 5 FASTENERS PER ULTIMATE CLIP @ 6” O.C. #8 OR #10 FULLY THREADED WOOD SCREW, 1” LONG FASTEN STARTER TRACK @ 12” O.C. #8 OR #10 FULLY THREADED WOOD SCREW, 1” LONG FACE FASTENERS TO CDX PLYWOOD @ 8” O.C. #8 OR #10 FULLY THREADED WOOD SCREW, 1 1/2” LONG FACE FASTENERS BACK TO STUDS @ 16” O.C. #8 OR #10 FULLY THREADED WOOD SCREW, 3 1/2” LONG, MIN. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A2.1 PROJECT NUMBER: 24212 EXTERIOR ELEVATIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 KEY NOTES FINISH SCHEDULE X X 3/16" = 1' 0" 1FRONT ELEVATION (SOUTH) 3/16" = 1' 0" 2BACK ELEVATION (NORTH) 3/16" = 1' 0" 3SIDE ELEVATION (EAST) 3/16" = 1' 0" 4SIDE ELEVATION (WEST) NOTE FOR GC: GC TO REVIEW DETAIL 9/ A8.1 & 12/A8.2, STARTER PANEL BEFORE STARTING TO INSTALL NICHIHA PANEL NUMBER DESCRIPTION E 2 LINE OF CANOPY / SOFFIT E 3 DARK BRONZE ANODIZED WINDOW FRAME W/ GRAY TINTED GLASS PER SOLARBAN SOLARGRAY SPECS, SEE GLAZING SCHEDULE ON SHEET A6.0 E 4 INTERNALLY ILLUMINATED SIGN (UNDER SEPERATE PERMIT) E 5 DARK BRONZE ANODIZED DOOR W/ GRAY TINTED GLASS STOREFRONT SYSTEM E 6 SERVICE DOOR, PAINT TO MATCH SURROUNDING WALL E 7 PRE FINISHED METAL FASCIA COPING E 8 NICHIHA FIBER CEMENT WALL PANEL SYSTEM E 9 WALL MOUNTED LIGHT FIXTURE, COLOR: BRONZE. SEE ELECTRICAL PLAN E 10 SERVICE DISCONNECT PANEL LOCATION. SEE ELECTRICAL PLAN E 11 ROOF LINE AND HVAC UNITS E 12 1 1/2" NICHIHA CORNER KEY EDGE, TYP. TO ALL CORNERS E 13 DOWNSPOUT, RE: PLUMBING PLAN E 14 ADDRESSING LOCATION: 8" TALL INCH BLACK NUMBERS. FINAL AREA LOCATION TO BE DETERMINED BY FIRE DEPARTMENT. E 15 1 3/8" THK. X 6" NICHIHA KURASTONE HIGH FIBER CEMENT WAINSCOT E 16 1 1/2" HIGH NICHIHA FIBER CEMENT CAP INSTALL PER MFR. SPECS. E 17 NICHIHA OVERHANG FLASHING, SEE DETAIL 2/A8.3 E 18 PARAPET WALL BEYOND E 19 (KNOX) KEY BOX AT 6' 0" AFF (IF REQUIRED BY FIRE DEPARTMENT). E 22 EMERGENCY FUEL SHUT OFF SWITCH, REFER TO FUEL SHEETS E 23 INSULATED METAL DOOR E 24 NICHIHA ESSENTIAL "STARTER" FLASHING 3" FROM THE HARD SURFACE. E 25 CO2 TANK WITH METAL LOUVERED CONTAINER E 26 EXTERIOR FINISH TO EXTEND ABOVE SIDEWALK/GRADE, SEE DET. 8/A8.1. E 29 METAL ROOF ACCESS LADDER WITH SECURITY DOOR LADDER GUARD MODEL # LG6 C1 P2 COTTERMAN E 30 CONTROL/EXPANSION JOINT "E.J." LOCATION, SEE DETAIL 5/A8.1 E 31 NICHIHA FIBER CEMENT SOFFIT PANEL. SEE DETAILS 1/A8.3 & 2/A8.3. E 33 WALL MOUNTED EMERGENCY LIGHT FIXTURE, COLOR: BRONZE. SEE ELECTRICAL PLAN E 34 DARK BRONZE ANODIZED WINDOW FRAME WITH SPANDREL GLASS. E 35 DOOR DECAL PROVIDED AND INSTALL BY GRAPHIC VENDOR. E 36 SCUPPER AND OVER FLOW DRAIN, SEE A1.7 & DETAIL 8/A8.3 & 9/A8.3 FOR SIZE E 37 PRE FINISHED METAL CORNICE E 42 EXIT DOOR PAINT TO MATCH SURROUNDING WALL E 43 INSULATED METAL DOUBLE LEAF DOOR IN HOLLOW METAL FRAME, SEE DOOR SCHEDULE A6.0 FASTENING SCHEDULE FOR NICHIHA PANEL FINISH FLOOR +0" B.O. CEILING+10' 10"FRP2 10.02 DC1 24"X36" LED SNAP FRAME SIGNS BY CIRCLE K DECOR VENDOR4" LETTERS BY CIRCLE K DECOR VENDOR 12" COOLERWALL ICONS QTY 8 BY CIRCLE K DECOR VENDOR 48" X 18" COOLER ICON CENTERED OVER COLD VAULT ENTRY BY CIRCLE K DECOR VENDOR FRP2 10 ' 1 0 " TYP. 08.03 B.O. TRUSS +12' 2" 3' 9 " 4' 1 3/4" 12' 7 5/8" SEE FLOOR PLAN 44' 8 5/8" 5 1/4" 11' 5 1/2" 8' 5" FRP2 13.04 R008 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 13.03 B1 TR 03 TR 03P1 DC3 10.02 06.02 16.07 P1 P2 H001 H001 H005 O001 B006 B503 FRP3 TR 03 TR 01 R007 R007 R007R007 P413 P1 FINISH FLOOR +0" FINISH FLOOR +0" B.O. CEILING +10' 10" 46" X 31" POLAR POP SIGN BY CIRCLE K DECOR VENDOR 46" X 31" FROSTER SIGN BY CIRCLE K DECOR VENDOR 24"x 36" LED SNAP FRAME BY CIRCLE K VENDOR VOMELA DC2 10.02 FRP2 30' 8 1/4" 4' 10 1/2" NOTE: GC TO COORDINATE WITH CK CM FOR THE CABINETS BELOW COUNTER B301B405 B301 B405 B406 B403 B001 B001 B101 B001 B404 B102 6' 9 " 4 ' 1 " P4 06.02 3' 9 " M011 B.O. TRUSS +12' 2" B.O. SOFFIT 10' 6" TR 03 10 ' 1 0 " M011B003B003 V101 FINISH FLOOR +0" M104 R401M107 LOTTO MACHINE LOTTO STANDTELE COM SUNGLASS & CELL PHONE SPINNER 4' 0 " V201 4" LETTERS BY CIRCLE K DECOR VENDOR 13.03 T001T001 13.0313.03 T107 06.02 08.01 DC1 P1 P1 P1 C001 C107 C107 C001C001 P204 M108 T011 T010 B1 DOOR DECAL PROVIDED AND INSTALL BY GRAPHIC VENDOR DOOR DECAL PROVIDED AND INSTALL BY GRAPHIC VENDOR B.O. TRUSS +12' 2" B.O. CEILING 10' 6" B.O. CEILING 10' 10" 16.06 16.06 B1 B1 24"x36" LED SNAP FRAMES (2) BY CIRCLE K DECOR VENDOR T108 B.O. CEILING 10' 6" P1 TR 09 TR 09 V004 V004 06.02 O008 O005 C002 C005 C109 C004 C106 8' 1 1/8"13' 10 3/8"29' 2"8' 3 7/8" P205 FINISH FLOOR +0" FINISH FLOOR +0" B.O. CEILING +10' 10" R203 33" x 22" RESTROOM SIGN BY CIRCLE K DECOR VENDOR DC410.02 FRP3 BEYOND P1 P1 P1 M012 R210 DOOR DECAL PROVIDED AND INSTALL BY GRAPHIC VENDOR B.O. TRUSS +12' 2" B.O. CEILING 10' 10" B1 B1 TR 03 FRP2 3' 9 " R008 27' 0" 6' 0" ? 10 ' 1 0 " 08.02 FFL 1 1 / 4 " 2' 5 " 2 3 / 4 " V101 2' 9 " 1 1 / 4 " 2 ' 5 " 2 3 / 4 " 4' 11" M007M006 2' 9 " 1 1 / 4 " 2 ' 5 " 2 3 / 4 " 5' 10" H206 H209 H106 O001 H209 V101 1 1 / 4 " 2 ' 4 3 / 4 " 3 3 / 4 " O001 H303 B006 H103 O001 H107 H104 H108 R207V101 2' 9 3 / 4 " 3 3 / 4 " 2' 4 3 / 4 " 1 1 / 4 " 4' 5" 3' 11" 2' 2" H109H110H111 FFL H209 O001 B006 V101 5' 1" 1 1 / 4 " 2' 4 3 / 4 " 3 1 / 2 " FFL V101 H104 H108 H206 H208 2' 9 3 / 4 " 5' 1" 3 3 / 4 " 2 ' 4 3 / 4 " 1 1 / 4 " M014 M014 1. SEE SHEET A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT. 2. VERIFY EQUIPMENT LAYOUT WITH CIRCLE K 3. ATM & BITCOIN SHALL COMPLY WITH SECTIONS 220 AND 707 OF THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN 4. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE EXPOSED PORTIONS OF DINING SURFACES AND WORK SURFACES. ICC A117.1 2009 CHAPTER 9, SEC 902.3 5. SEE SHEET A1.11 FOR INTERIOR FINISHES * * M014 H103O001 H111 H110H109 R207 H104 H107 H108 H206 H209 H209 O001 H106 O001 B006 H207 M007 M006 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A3.1 PROJECT NUMBER: 24212 INTERIOR ELEVATIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 GENERAL NOTES KEYNOTES NUMBER DESCRIPTION 06.02 CUSTOM CASEWORK SUPPLIED BY CIRCLE K, INSTALLED BY CIRCLE K VENDOR. 08.01 ALUMINUM STOREFRONT SYSTEM, SEE SHEET A6.0. 08.02 INSULATED METAL DOOR IN HOLLOW METAL FRAME. 08.03 HOLLOW METAL DOOR IN HOLLOW METAL FRAME. SEE DOOR SCHEDULE ON SHEET A6.0 10.02 GRAPHICS SUPPLIED AND INSTALLED BY CIRCLE K DECOR VENDOR NO WALL PENETRATIONS IN GRAPHIC AREAS. 13.03 COOLER REACH IN DOOR BY MANUFACTURER. 13.04 COLD VAULT DOOR BY MANUFACTURER. 16.06 LED LIGHTING BY VENDOR. 16.07 WALL MOUNTED BLUE LED LIGHTING. SEE ELECTRICAL. 1/4" = 1' 0" 1AREAR WALL ELEVATION (COLD VAULT/COOLER WALL/BACK ROOM) 1/4" = 1' 0" 1BRIGHT WALL (FOOD AREA/FOUNTAIN WALL) 1/4" = 1' 0" 1CFRONT WALL (COFFEE WALL/ENTRY/CASHIER/ENTRY/SEATING AREA) 1/4" = 1' 0" 1DLEFT WALL (REACH IN FREEZER WALL/HALLWAY/BEER CAVE) COFFEE CONDIMENTS ISLAND HOT FOOD + ROLLER GRILL ISLAND BEER TROUGH 1. INTERIOR ELEVATIONS AT SALES FLOOR (107) PLAN LEFT SIDE FRONT / REAR TYP.RIGHT SIDE RIGHT LEFT PLAN FRONT REAR FFL 30" X 54" BEER TROUGH PLAN RIGHT SIDE SIDE 2.CABINET ELEVATIONS AT SALES FLOOR (107) XX.XX FINISH FLOOR +0" FRP1 A9.2 4 B1 FRP1 08.03 V201 FRP1 4' 0 " B1TR 09 B.O. LOFT 7' 6" B.O. CEILING 10' 8" TR 09 FINISH FLOOR +0" P401 FRP1 A9.2 4 DRE 52 18 FRP1 FRP1 V201 B603 B603 B603 B603 B603 S003 S003 S003 4' 10" 4' 8" 14' 0" 6' 0" 16" X 16" ACCESS PANEL, GC TO COORDINATE LOCATION AS NEEDED FOR EQUIPMENT INSTALLATION B1 TR 09 P402 B1 B1 TR 09 B1TR 09 FRP1 4' 0 " B.O. LOFT 7' 6" B.O. CEILING 10' 8" 40 " M A X . VEEDER ROOT 1' 0 " 7 ' 0 " B503 B503 FINISH FLOOR +0" P001 P203 P401 A9.2 1 P002 MOP BUCKET FRP1 S101 S101 B1 B.O. LOFT 7' 6" B.O. CEILING 10' 8" O005 P414 FINISH FLOOR +0" T201 V005 O004 V006 B1B1 B1 08.02 V001 V001 V001 V001 S003 S003 S003 S003 S003 GC TO VERIFY SHOP DRAWING FOR STUB UP FRP1 FRP1 B.O. LOFT 7' 6" B.O. CEILING 10' 8" FINISH FLOOR +0" S007 FRP1 A9.2 4 S007 B.O. LOFT 7' 2" B1 B.O. CEILING 10' 8" FINISH FLOOR +0" A9.2 4 B1 S007 S007 B.O. LOFT 7' 2" B.O. CEILING 10' 8" FRP1 FINISH FLOOR +0" A9.2 4 S007S007 B.O. LOFT 7' 2" FRP1 B1 B.O. CEILING 10' 8" FINISH FLOOR +0" A9.2 4 08.03 FRP1 B1 B.O. LOFT 7' 2" B.O. CEILING 10' 8" FINISH FLOOR +0" B.O. CEILING +10' 10" T011T010 B.O. CEILING 10' 6" T011T010 2' 1 0 " T109 FINISH FLOOR +0" B.O. CEILING +10' 10" H202 H203 H201 64" TALL CIG RACK 64" TALL CIG RACK 64" TALL CIG RACK 64" TALL CIG RACK 64" TALL CIG RACK B.O. CEILING 10' 6" 06.02 FINISH FLOOR +0" B.O. CEILING +10' 10" 64" TALL CIG RACK T001 08.01 T107 P1 B1 B.O. CEILING 10' 6" T108 T104 06.02 FINISH FLOOR +0" B.O. CEILING +10' 10" UNDER COUNTER SAFE T101T105 T007 T011 T010 B.O. CEILING 10' 6" FINISH FLOOR +0" B.O. CEILING +10' 10" H211 H205 R202 H401 LOCKABLE CARTON STORAGE FLEX SPACE 06.02 B.O. CEILING 10' 6" B.O. CEILING +10' 10" H203 H202H201 R202 H205 H211 R206 P204 O005 O008 FINISH FLOOR +0" B.O. CEILING+10' 10" H202 H201 H203 H401 LOCKABLE CARTON STORAGE P1 B1 R206 08.01 B.O. CEILING 10' 6" B.O. CEILING +10' 10" LOCKABLE CARTON STORAGE LOCKABLE CARTON STORAGE LOCKABLE CARTON STORAGE LOCKABLE CARTON STORAGE COATS 06.02 1. SEE SHEET A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT. 2. VERIFY EQUIPMENT LAYOUT WITH CIRCLE K 3. SEE SHEET A1.2 FOR INTERIOR FINISHES * * REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A3.2 PROJECT NUMBER: 24212 INTERIOR ELEVATIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 GENERAL NOTES KEYNOTES NUMBER DESCRIPTION 06.02 CUSTOM CASEWORK SUPPLIED BY CIRCLE K, INSTALLED BY CIRCLE K VENDOR. 08.01 ALUMINUM STOREFRONT SYSTEM, SEE SHEET A6.0. 08.02 INSULATED METAL DOOR IN HOLLOW METAL FRAME. 08.03 HOLLOW METAL DOOR IN HOLLOW METAL FRAME. SEE DOOR SCHEDULE ON SHEET A6.0 1/4" = 1' 0" 1CFRONT ELEVATION 1/4" = 1' 0" 1DLEFT ELEVATION (FOUNTAIN WALL) 1/4" = 1' 0" 1AREAR ELEVATION 1/4" = 1' 0" 1BRIGHT ELEVATION 1/4" = 1' 0" 2DLEFT ELEVATION 1/4" = 1' 0" 2AREAR ELEVATION 1/4" = 1' 0" 2BRIGHT ELEVATION 1/4" = 1' 0" 2CFRONT ELEVATION 1/4" = 1' 0" 3AREAR ELEVATION 1/4" = 1' 0" 3BRIGHT ELEVATION 1/4" = 1' 0" 3CFRONT ELEVATION 1/4" = 1' 0" 3DLEFT ELEVATION 1/4" = 1' 0" 4AREAR ELEVATION 1/4" = 1' 0" 4BRIGHT ELEVATION 1/4" = 1' 0" 4CFRONT ELEVATION 1/4" = 1' 0" 4DLEFT ELEVATION F.R.P. ON GYP. + SIP + PLYWOOD WALL PANEL SEE SHEET A1.2 F.R.P. ON PLYWOOD SEE SHEET A1.2 F.R.P. ON PLYWOOD SEE SHEET A1.2 3. INTERIOR ELEVATIONS AT CASHIER (108)4. INTERIOR ELEVATIONS AT PREP AREA (110) 2. INTERIOR ELEVATIONS AT STORAGE ROOM (103) 1. INTERIOR ELEVATIONS AT BACK ROOM (109) F.R.P. OVER GYP. + SIP + PLYWOOD WALL PANEL. SEE SHEET A1.2 XX.XX 9' - 0" CEILING HT. 0' - 0" FIN. FLOOR SALES AND SERVICE COUNTERS ADAAG 904.4 NOTE: ADAAG GENERALLY SPECIFIES ACCESSIBLE COUNTER HEIGHTS UP TO 34" (902.3) MISC. FIXTURES 3' 0" FULL HEIGHT COUNTER 30 " . 2 4 " M A X . 34 " M A X . 24" MAX.30". COAT HOOK 48 " M A X . 40 " M A X . TRASH 1' 7 " . 2' 2". SEAT COVER DISPENSER 12". 3' 3 " . SANITARY NAPKIN DISPOSAL SANITARY NAPKIN / TAMPON DISPENSER T.P. HOLDER 1' 9 " . 2' 0" THERMOSTAT LIGHTS OUTLETS 15 " . BABY CHANGING TABLE 1' 7" 33 " M I N . MA X T O H A N D L E 4' 0 " 33 " 3 6 " BABY CHANGING TABLE OPTIONAL STRAP HANDLE IF REQUIRED 39 " 4 1 " 1 1 / 2 " M I N . MI N . 12 ' . 18 " M I N . 54" MIN. 7" 9" MAX. 48 " M A X . 15 " M I N . TOILET PAPER DISPENSER 42" MIN.12" MAX. 4" MAX. DEEP CONVENIENCE SHELF WITH ROUNDED EDGE TOILET ELEVATION SIDE 39" 41" TOILET ELEVATION FRONT * FOR ACCESSIBLE STALLS ONLY 33 " 3 6 " 16" 18" 17 " 1 9 " 24" MIN. MIN. 12". 36" MIN. ℄ TOILET PARTITION OR FINISHED FACE OF WALL FLUSH VALVE 17 " M A X . 48 " M A X . URINAL ELEVATIONDRINKING FOUNTAINSLAVATORY CLEARANCES 17" 19" 36 " M A X . 34 " . 27 " H O L D 9" M A X . 6" MAX.8" MIN. INSULATED PIPES MIRROR PROVIDE CODE COMPLIANT HAND CONTROLS SU R F A C E 40 " M A X . TO R E F L E C T I V E 34 " M A X . 29 " M I N . 27 " M I N . 18 " M I N . CLEARANCE 8" MAX. KNEE CLEARANCE 6" MAX. TOE 17" MIN.SIDEFRONT 20 " . HAND DRYER 3' 2 " ROYSTON SOLID SURFACE GUARD 40 " M A X . TOWEL DISPENSER FINISH FLOOR +0" B.O. CEILING +9' 0" P101 FRP2 TR 03 TR 02 P304 P302 P302 P305 O007 P1 TR 01 FINISH FLOOR +0" B.O. CEILING +9' 0"CONVENIENCE SHELF 06.03 O008 P101 A9.1 10 PARTITION WALL FRP3 P1 P301 P301 P304 O007 P304 O007 P304 O007 O008P1 FRP2 P305 P305 P302 P305 P305 TR 01 TR 01 TR 02 FRP4 TR 03 FRP2 TR 03 P101 P101 P101 P105 P106P106 P1 P1 24" MIN. 3' 0" FINISH FLOOR +0" B.O. CEILING +9' 0" P1 FRP3 FRP3 O008 P301 P311 TR 03 TR 03 TR 01 54 " P1 P106 FINISH FLOOR +0" B.O. CEILING +9' 0" 1' 8 " 1' 0 " PARTITION WALL FRP4 P307 FRP4 FRP2 FRP2TR 02 TR 01 TR 02 TR 03 4' 6 " P1 FINISH FLOOR +0" B.O. CEILING +9' 0" P101 P302 P305 TR 03 TR 02 FRP4 FRP2 TR 01 54 " O007 P1 FINISH FLOOR +0" B.O. CEILING +9' 0" PARTITION WALL 1' 8 " TR 01 FRP2TR 02 TR 03 P1 FRP2 TR 02 TR 03 P307 1' 0 " FRP4FRP4 TR 01 FINISH FLOOR +0" B.O. CEILING +9' 0" FRP3 P1 P301 O008 P311 FRP3 TR 01 54 " TR 03 P106 P1 P307 TR 01 B.O. CEILING +9' 0" PARTITION WALL CONVENIENCE SHELF FRP3 FRP2 06.03 P301 P101 A9.1 10 P301 O008 O008 FIN. FLOOR 0' 0"O007 FRP2 FRP4 TR 01 TR 02 TR 01 P103 P103 P106 P106 P305 TR 03TR 03 54 " P305 24" MIN. 3' 0" P302 P105 P1P1P1 O007 FRP4 A3.33D 3C 3B 3A A3.3 4C 4D 4A 4B MEN'S RESTROOM 102 HALLWAY 111 A3.3 2A 2C 2D BC S BC S TRASH CAN TRASH CAN WOMEN'S RESTROOM 101 A3.3 8 FINISH FLOOR +0" B.O. CEILING +9' 0" VERTICAL RUNNING BOND FRP PANEL STARTING POINT NOTE: THIS IS A GENERIC WALL ELEVATION FOR PATTERN AND STARTING POINT ONLY. FRP PANEL SCHLUTER QUADEC FRP PANEL COVE SCHLUTER FRP4 FRP2 P1 TR 01 TR 02 TR 03 WALL PAINT 12 " 2' 6 " 2 ' 0 " 4 ' 6 " FINISH FLOOR +0" P1 B.O. CEILING +10' 10" OPENING TO RESTROOM VESTIBULE FRP3 P1 FRP3 TR 01 TR 01 TR 03 TR 03 54 " FINISH FLOOR +0" B.O. CEILING +9' 0" B.O. CEILING +10' 10" 8' 6 " (HALLWAY)(RESTROOM VESTIBULE) 08.02 P1 TR 02 FRP3 FRP4 TR 01 TR 03 P1 TR 03 FRP2 FINISH FLOOR +0" B.O. CEILING +10' 10" 08.03 FRP3 P1 27 " M I N . SP O U T @ H . C . 36 " M A X . T . O . SP O U T @ S T A N D I N G 38 " M I N . T . O . TR 01 TR 02 TR 01 P1 FRP3 54 " TR 03 TR 03 P413 1. SEE SHEET A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT SCHEDULE. 2. CLEAR ACCESS A MIN. OF 44" IN WIDTH THROUGHOUT SANITARY FACILITY TO REACH THE HANDICAPPED COMPARTMENT. (48" CLEAR @ HINGE SIDE APPROACH TO COMPARTMENT). 3. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" DIA.. CIRCLE WITHIN THE SANITARY FACILITY ROOM AT A HEIGHT OF 27" A.F.F. DOORS OTHER THAN THE TOILET COMPARTMENT DOOR MAY NOT ENCROACH MORE THAN 12". 4. SEE SHEET A1.11 FOR INTERIOR FINISHES INTERIOR COMPARTMENT: 1. FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA. 2. MAXIMUM HEIGHT FROM FLOOR TO FLUSH VALVE TO COMPLY SECTION 308 (ICC/ANSI 117.1). 3. 5 lb. MAXIMUM FORCE TO OPERATE VALVE. 4. SEE TOILET ACCESSORY MOUNTING HEIGHTS DETAIL FOR HEIGHTS OF GRAB BARS AND ACCESSORIES. 5. VERTICAL GRAB BARS REQUIRED AT ALL ACCESSIBLE TOILETS. 6. PROVIDE 30X48 ADA ACCESSIBLE SPACE AT LAV. 7. INSULATE WATER AND DRAIN PIPES 8. INSTALL BACKING FOR CHANGING TABLE 9. CHANGING TABLE TO BE INSTALLED BY G.C. 10.PROVIDE SOLID BLOCKING AT WALL FOR SHELVING * * XX.XX WALL PAINT FRP PANEL VERTICAL RUNNING BOND COVE SCHLUTER P1 FRP3 TILE PATTERN STARTING POINT TR 01 TR 03 4' 6 " SCHLUTER RONDEC WALL PAINT COVE SCHLUTER P1 FRP3 TR 03 FRP PANEL VERTICAL RUNNING BOND SCHLUTER RONDEC 3 5/8" 20ga. METAL TRACK 3 5/8" 20ga. METAL STUDS @ 16" O.C. 5' 0"x3' 0" HOLLOW METAL DOOR, IN 7' 0"x3' 0" METAL FRAME OPEN OPEN OPEN OPEN 7C A9.1 ______10 A9.1 ______ 7 A9.1 ______ 7A A9.1 ______ 6" 3' 0" 7' 0 " 4" 1' 8 " 1' 0 " 7B A9.1 ______ FINISH FLOOR +0" B.O. CEILING +9' 0" P308 P308 P307 P307 FRP3 P1 TR 01 FRP2 TR 01 TR 02 FRP4 OPEN OPEN OPEN OPEN REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A3.3 PROJECT NUMBER: 24212 INTERIOR ELEVATIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1/4" = 1' 0" 1FIXTURE MOUNTING DETAILS 1/4" = 1' 0" 4CWOMEN'S RESTROOM FRONT ELEVATION 1/4" = 1' 0" 4DWOMEN'S RESTROOM LEFT ELEVATION 1/4" = 1' 0" 4AWOMEN'S RESTROOM REAR ELEVATION 1/4" = 1' 0" 4BWOMEN'S RESTROOM RIGHT ELEVATION 1/4" = 1' 0" 3CMEN'S RESTROOM FRONT ELEVATION 1/4" = 1' 0" 3DMEN'S RESTROOM LEFT ELEVATION 1/4" = 1' 0" 3AMEN'S RESTROOM REAR ELEVATION 1/4" = 1' 0" 3BMEN'S RESTROOM RIGHT ELEVATION 3/16" = 1' 0" 7RESTROOM KEY PLAN 1/4" = 1' 0" 5TYP. RESTROOM WALL PATTERN GENERAL NOTES KEYNOTES NUMBER DESCRIPTION 06.03 CUSTOM LAVATORY COUNTERTOP SUPPLIED BY CIRCLE K, INSTALLED BY OTHERS 08.02 INSULATED METAL DOOR IN HOLLOW METAL FRAME. 08.03 HOLLOW METAL DOOR IN HOLLOW METAL FRAME. SEE DOOR SCHEDULE ON SHEET A6.0 1/4" = 1' 0" 2CHALLWAY (111) FRONT ELEVATION 1/4" = 1' 0" 2DHALLWAY (111) LEFT ELEVATION 1/4" = 1' 0" 2AHALLWAY (111) REAR ELEVATION 1/4" = 1' 0" 6RESTROOM PARTITION WALL FRAMING 2. ELEVATIONS AT HALLWAY 1 (111) 3. ELEVATIONS AT MEN'S RESTROOM (102) 4. ELEVATIONS AT WOMEN'S RESTROOM (101)NOTE: G.C. TO PROVIDE SCHLUTER "RONDEC" TRIM (TR 01) ON ALL INSIDE / OUTSIDE TILE CORNERS 1/4" = 1' 0" 8RESTROOM ENTRY ELEVATION FINISH FLOOR +0" FINISH FLOOR +0" A B B.O. CEILING +9' 0" B.O. CEILING +10' 10" BACK ROOM 109 SALES FLOOR 107 MEN'S RESTROOM 102 A9.2 4SALES FLOOR 107 A5.1 2A5.1 3 T.O. WAINSCOT CAP +3' 1 3/4" T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" B.O. TRUSS +12' 2" T.O. TOWER +21' 6" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" T.O. PARAPET +18' 6" K 10 K 01K 01 K 03 K 06 K 09 K 08 K 08K 13K 14K 04 K 02 K 06 K 03 K 04 K 14 K 08K 08 WOMEN'S RESTROOM 101 (BEYOND) R008 3' 9 " K 16 K 16 FINISH FLOOR +0" FINISH FLOOR +0" 1 2 B.O. CEILING +10' 10" A5.2 2 WALK IN COOLER 104 SALES FLOOR 107 A9.2 5 HALLWAY 111T.O. WAINSCOT CAP +3' 1 3/4" T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" B.O. TRUSS +12' 2" T.O. ROOF PANEL+17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" K 01 K 04 K 05 K 07K 07 K 08 K 06 K 01 K 03 K 04K 02 B.O. CEILING 10' 6" T.O. TOWER +23' 0" K 16K 16 FINISH FLOOR +0" FINISH FLOOR +0" 1 2 B.O. CEILING +10' 10" A5.2 3 COLD VAULT 105 SALES FLOOR 107 HALLWAY 111 T.O. WAINSCOT CAP +3' 1 3/4" T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2"B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" T.O. PARAPET +18' 6" K 01 K 08 K 02K 03 K 04 K 08 K 06 K 16K 16 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A4.0 PROJECT NUMBER: 24212 BUILDING SECTIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 KEYNOTES 3/16" = 1' 0" 1BUILDING SECTION 3/16" = 1' 0" 3BUILDING SECTION 3/16" = 1' 0" 4BUILDING SECTION NUMBER DESCRIPTION K 01 CONCRETE SLAB WITH MINIMUM 15ML VAPOR BARRIER LAPPED A MINIMUM OF 6" & TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL. CONCRETE SLAB, SEE STRUCTURAL FOR REINFORCING. K 02 ROOF JOIST K 03 TPO ROOFING SYSTEM OVER SIP ROOF PANEL. WALKWAYS AS REQUIRED BY ROOFING MANUFACTURE. K 04 PARAPET BEYOND K 05 ROOF TOP HVAC UNIT, SEE MECHANICAL DRAWINGS. K 06 SIP WALL PANEL.SEE SIP SHEETS. K 07 WALK IN FREEZER/COOLER WALL. K 08 ALL DUCT WORK TO GO THROUGH TRUSSES. K 09 SWITCHGEAR CABINET BEYOND. K 10 EXTERIOR ROOF ACCESS LADDER WITH SECURITY DOOR. K 13 DRAFT STOP SEE DETAIL 1/A8.3. K 14 ROOF DRAIN SCUPPER AND EMERGENCY RELIEF SCUPPER. K 16 2" RIGID INSULATION BELOW GRADE 24" HORIZONTAL AND VERTICAL FINISH FLOOR +0" B BACK ROOM 109 A8.1 8 A8.1 9 A8.3 3 A8.3 10 T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" B.O. LIGHT FIXTURE +14' 6" J 03 J 01 J 02 J 36J 35 J 20 J 05 J 10 J 19 J 13J 11 J 30 J 30 J 14 J 23 J 24 J 19 J 40 J 40 FINISH FLOOR +0" A MEN'S RESTROOM 102 A8.3 3 A8.3 10 A8.1 8 A8.1 9 T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" J 11 J 09 J 05 J 23J 23 J 13 J 19 J 10 J 19 J 10 J 01 J 03 J 32 J 14 J 30 J 30 J 24 J 18 J 40 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A5.1 PROJECT NUMBER: 24212 WALL SECTIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 SHEET A5.1 AND A5.2 HAVE THE SAME KEY NOTES, APPLICABLE KEY NOTES ARE NOTED ON WALL SECTION KEYNOTES 1/2" = 1' 0" 2WALL SECTION 1/2" = 1' 0" 3WALL SECTION NUMBER DESCRIPTION J 01 CONCRETE SLAB WITH MINIMUM 15ML VAPOR BARRIER LAPPED A MINIMUM OF 6" & TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL. J 02 CONCRETE WALK, BROOM FINISH., SEE SITE PLAN SHEET SD1.1 /CIVIL PLANS J 03 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION. J 05 WOOD TRUSSES, SEE SIP DRAWINGS FOR SPECIFIC INFORMATION. J 09 2X BLOCKING, SEE SIP SHEETS. J 10 5/8" THK. X 17 7/8"H X 71 9/16"L FIBER CEMENT WALL NICHIHA PANEL SYSTEM PER MANUFACTURER SPECIFICATIONS OVER FELT WATER RESISTIVE BARRIER. REFER TO EXTERIOR DETAILS ON SHEETS A8.1, A8.2 & A8.3 J 11 TPO ROOFING SYSTEM OVER SIP ROOF PANEL. WALKWAYS LOCATED PER ROOF PLAN. SEE ROOF PLAN FOR R 33. J 13 EXTEND TPO ROOFING TO UNDERSIDE OF METAL FASCIA OVER TOP OF WALL. J 14 PARAPET/TOWER BEYOND J 18 GYPSUM BOARD CEILING J 19 SIP WALL PANEL.SEE SIP SHEETS. J 20 GRID CEILING, SEE RCP SHEET A1.6 AND DETAILS 10 & 11/A9.2. J 23 1/2" EXPANSION JOINT MATERIAL. J 24 PRE FINISHED SNAP ON GALV. METAL FASCIA J 30 FIBER CEMENT NICHIHA WALL PANEL SYSTEM BEYOND J 32 METAL STUDS CONSTRUCTION. J 35 STORAGE SHELF SEE DETAIL 4/A9.2 J 36 LINE OF MAIN SWITCHGEAR BEYOND J 40 2" THK. BELOW GRADE RIGID INSULATION 24" HORIZONTAL & VERTICAL FINISH FLOOR +0" B.O. CEILING +9' 0" 1 A8.3 3 B.O. TRUSS+12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" J 01 J 18 J 19 J 10 J 19 J 02 J 03 J 23 J 23 J 24 J 13 J 07 J 09 J 19 J 10 1/4" / 1' 0" 1' 6" J 07 A9.3 1 J 50 J 40 J 40 FINISH FLOOR +0" 1 B.O. CEILING+10' 10" A8.1 10 A8.1 6 A8.3 10 A8.3 3 A8.2 12 A8.3 2 T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" T.O. TOWER +21' 6" T.O. PARAPET +18' 6" J 03 J 01 J 04 J 28 J 30 J 29 J 25 J 26 J 39 J 10 J 31 J 09 J 09 J 13J 19 J 10 J 24 J 09 J 34 J 19 J 09 J 25 J 20 J 19 J 23 J 30 SALES FLOOR 107 1' 6" 1/4" / 1' 0" J 53 J 40 FINISH FLOOR +0" 1 B.O. CEILING +10' 10" A8.3 10 A8.2 4 A8.2 12 A8.2 3 A8.3 2 T.O. WAINSCOT CAP +3' 1 3/4" B.O. TRUSS +12' 2" T.O. ROOF PANEL +17' 4" J 01 J 03 J 23 J 29 J 30 J 10 J 27J 39 J 25 J 05 J 21 J 19 J 34 J 09 J 10 J 09 J 13 J 14 J 11 J 28 J 20 J 24 J 19 J 26 SALES FLOOR 107 J 10 3' 0" 1/4" / 1' 0" T.O. TOWER +23' 0" J 06 J 40 J 40 A8.1 3 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A5.2 PROJECT NUMBER: 24212 WALL SECTIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1/2" = 1' 0" 1WALL SECTION 1/2" = 1' 0" 3WALL SECTION 1/2" = 1' 0" 2WALL SECTION SHEET A5.1 AND A5.2 HAVE THE SAME KEY NOTES, APPLICABLE KEY NOTES ARE NOTED ON WALL SECTION KEYNOTES NUMBER DESCRIPTION J 01 CONCRETE SLAB WITH MINIMUM 15ML VAPOR BARRIER LAPPED A MINIMUM OF 6" & TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL. J 02 CONCRETE WALK, BROOM FINISH., SEE SITE PLAN SHEET SD1.1 /CIVIL PLANS J 03 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION. J 04 1 3/8" THK FIBER CEMENT KURASTONE NICHIHA WALL SYSTEM PER MANUFACTURER SPECIFICATIONS. REFER EXTERIOR DETAIL SHEET A8.1 J 05 WOOD TRUSSES, SEE SIP DRAWINGS FOR SPECIFIC INFORMATION. J 06 2X WOOD STUD @ 16" O.C., SEE SIP DRAWINGS. J 07 2X DOUBLE TOP PLATE @ 12' 2" A.F.F., SEE SIP SHEETS. J 09 2X BLOCKING, SEE SIP SHEETS. J 10 5/8" THK. X 17 7/8"H X 71 9/16"L FIBER CEMENT WALL NICHIHA PANEL SYSTEM PER MANUFACTURER SPECIFICATIONS OVER FELT WATER RESISTIVE BARRIER. REFER TO EXTERIOR DETAILS ON SHEETS A8.1, A8.2 & A8.3 J 11 TPO ROOFING SYSTEM OVER SIP ROOF PANEL. WALKWAYS LOCATED PER ROOF PLAN. SEE ROOF PLAN FOR R 33. J 13 EXTEND TPO ROOFING TO UNDERSIDE OF METAL FASCIA OVER TOP OF WALL. J 14 PARAPET/TOWER BEYOND J 18 GYPSUM BOARD CEILING J 19 SIP WALL PANEL.SEE SIP SHEETS. J 20 GRID CEILING, SEE RCP SHEET A1.6 AND DETAILS 10 & 11/A9.2. J 21 RECESSED SOFFIT LIGHT, SEE ELECT & RCP SHEET. J 23 1/2" EXPANSION JOINT MATERIAL. J 24 PRE FINISHED SNAP ON GALV. METAL FASCIA J 25 I BEAM, SEE STRUCTURAL J 26 FLY REGLET SOFFIT VENT, SEE DETAIL 2/A8.3 J 27 ATTIC ACCESS HATCH AT SOFFIT AREA, SEE SHEET A1.6 FOR LOCATION AND DETAIL 2/A8.1 J 28 PILASTER BEYOND J 29 ALUMINUM STOREFRONT SYSTEM J 30 FIBER CEMENT NICHIHA WALL PANEL SYSTEM BEYOND J 31 PROVIDE & INSTALL 1/2" GYPSUM BOARD VERTICALLY AT HORIZONTAL INTERVALS OF MAXIMUM 10' 0" SPACING FOR FIRE BLOCKING OF CONCEALED COMBUSTIBLE SPACES TO COMPLY WITH IBC SECTION 718.2.2 J 34 5/8" GYPSUM WALL BOARD EXTEND ABOVE CEILING J 39 NICHIHA WALL SYSTEM PANEL OVER OSB SHEATHING, SEE DETAIL 2/A8.3 J 40 2" THK. BELOW GRADE RIGID INSULATION 24" HORIZONTAL & VERTICAL J 50 ALL DUCT WORK TO GO THROUGH TRUSSES SEE MECH. J 53 WATER RESISTIVE BARRIER OVER SIP PANEL. 6 A8.2 ______ 12 A8.2 ______ 9 A8.2 ______ T 9 A8.2 ______ 6 A8.2 ______ 12 A8.2 ______ T 4 A8.2 ______ T 1 A6.1 ______2 A6.1 ______ 4 A6.1 ______ BA 7' 4 " 3 ' 1 3 / 4 " 10 ' 5 3 / 4 " 16' 10" 2" EQ. 2" EQ. 2" EQ. 2" EQ. 2" 2" 3 ' 1 3 / 4 " 2 " 7 ' 0 " 2"EQ. 2" EQ. 2" EQ. 2" 15' 10" B1 B1 B 15' 10" 2"EQ. 2" EQ. 2" EQ. 2" 2" 3' 0" 12' 8"12' 8" 3' 0" 2" 4' 2"2" 2"EQ. 2" EQ. 2" 12' 8" C 1 4' 4" 8' 4" B2 S S C B2 NOTE: G.C. TO USE 1" INSULATED, DOUBLE PANED GRAY TINTED GLASS FOR ALL STOREFRONT WINDOW PER SHEET A2.1 = TEMPERED SAFETY GLAZINGT = SPANDREL GLASS TO MATCH GRAYS 3 A6.1 ______6 A8.1 ______ T SS 1' 0 " 5 ' 6 " 6 " 7' 0 " 3' 0" 5" 2' 2" 5" D1 3' 0"3' 0" 7' 0 " D2 D3 3' 0" 7' 0 " D4 3' 7 " 1' 0 " 5 ' 0 " WIDTH DOOR D6 PANIC HARDWARE W/ BATTERY POWERED DOOR ALARM PROVIDE 30"X34" KICK PLATE (BOTH SIDES) INSULATED METAL DOOR PROVIDE 4"WX24"H TEMPERED VIEW PANEL T NOTE: INTERIOR DOOR AND DOOR FRAME PAINT, REFER FINISH P5 ON ROOM FINISH SCHEDULE SHEET A1.11 PROVIDE 30"X34" KICK PLATE (BOTH SIDES) 8' 0 " 2' 0" 3' 0" D5 PANIC HARDWARE W/ HARDWIRED DOOR ALARM INSULATED METAL DOOR PROVIDE 30" X 22" KICK PLATE PROVIDE 30"X34" KICK PLATE 1' 0 " 5 ' 0 " 1 ' 0 " 7' 0 " 2 " 2"2" 2" 7 ' 0 " 2"2" F1 F2 GALVANIZED COATING; PAINT AS SCHEDULED GALVANIZED COATED; FOR PAINT FINISH, REFER TO SHEET A1.11 2"2" 2" 8' 0 " F3 1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES. 2. PROVIDE A 60"x60" MIN. LANDING ON STRIKE SIDE OF DOOR W/ 44" MIN. WIDTH IN DIRECTION OF TRAVEL. 3. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3 FT. WIDE BY NOT LESS THAN 6' 8" HIGH CAPABLE OF OPENING 90°. SO THAT THE CLEAR WIDTH OF THE EXITWAY IS 32" MIN. THRESHOLD TO BE A MAX. 1/4" ABOVE ADJACENT FINISH FLOOR. 4. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. FOR INTERIOR DOOR AND 8 LBS. FOR EXTERIOR DOOR. 5. THE BOTTOM OF ALL DOORS WITHIN 12" OF FLOOR EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 6. PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. (30" TO 44" A.F.F.) 1. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND 1:10. 2. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED (3" MIN.) 3. LETTERS AND NUMERALS SHALL BE RAISED 1/32 IN. UPPER CASE, SANS SERIF OR SIMPLE TYPE AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8" (16mm) HIGH, BUT NO HIGHER THAN 2 IN. (50mm). PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERVAL DESCRIPTIONS PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 IN. (152mm) MINIMUM IN HEIGHT. 4. THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL MATTE OR OTHER NON GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 5. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE 48" MINIMUM MEASURED FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER OR 60" MAXIMUM MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY APPROACH WITHIN 3 IN (76mm) OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SET No. 1 1 CONTINUOUS HINGE PEMKO DFM_83SLF FINISH D 1 DEADLOCK ADAMS RITE MS1850S 310 FINISH 313 1 CORE YALE A600 MK FINISH 613E 1 THUMBTURN YALE S2053 MORTISE THUMBTURN FINISH 613E 1 PULL/PUSH BAR ROCKWOOD BF15847 33 T4HD MOUNTING FINISH US10B 1 SURFACE CLOSER YALE UNI 4400 690 488 293S FINISH 690 1 THRESHOLD PEMKO HALF SADDLE 2005AV36 (MSES25SS) FINISH A **WEATHER STRIPPING PACKAGE PROVIDED BY DOOR AND FRAME MFR. 1 PLASTIC SIGN: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". (IBC 2015 SECTION 1010.1.9.3) NOTE: DOOR PULL ON 108B ONLY SET No. 2 1 CONTINUOUS HINGE PEMKO CFM83_HD1 FINISH C 1 ELECTRONIC DIGITAL LOCK TRILOGY T2 DL27 00 IC/US26D 1 CORE YALE A600 MK 626 FINISH 626 1 SURFACE CLOSER YALE 3521T HOLD OPEN THUMBTURN FINISH 689 2 ARMOR PLATE ROCKWOOD K1050 30 X 34" LDW FINISH US32D 3 DOOR SILENCER ROCKWOOD 608 FINISH GRY SET No. 3 1 CONTINUOUS HINGE PEMKO CFM83_HD1 FINISH C 1 EXIT ALARM DEVICE YALE 6100 A ALR EO BSP (EXIT ONLY) FINISH BSP 1 CYLINDER YALE K640 MORTISE CYLINDER FINISH 626 1 CORE YALE A600 MK 626 FINISH 626 1 SURFACE CLOSER YALE UNI 4400 689 3' 0" DOOR FINISH 689 1 KICK PLATE ROCKWOOD K1050 30 X 34" LDW US32D FINISH US32D 1 THRESHOLD PEMKO 2005AP72 (MSES25SS) FINISH A 1 HEAD SEAL PEMKO 2891APK 36 FINISH A 2 SET OF SEALS PEMKO 303AS84 FINISH A 1 RAIN DRIP PEMKO 346A40 FINISH A 1 DOOR SWEEP PEMKO 3452APK36 FINISH A SET No. 4 2 CONTINUOUS HINGES PEMKO DFM83SLF FINISH D 2 FLUSH BOLT ROCKWOOD 555 US10B FINISH US10B 1 EXIT ALARM DEVICE ACCENTRA 6160 A ALR 36" EO 613E (EXIT ONLY) FINISH 613E (NO PUSH BAR ON INACTIVE LEAF) 1 WIRE HARNESS 60 7700 0290 999 (FOR EXIT ALARM DEVICE) 1 POWER SUPPLY 784 (FOR EXIT ALARM DEVICE) 1 CYLINDER ACCENTRA K660/ LOCKNET LN2049D MORTISE CYLINDER HOUSING FINISH 613 1 CORE ACCENTRA A600 MK FINISH 613E 1 SURFACE CLOSER ACCENTRA UNI 4400 690 488 6190 FINISH 690 1 OVERHEAD DOOR STOP RIXSON 10 136 613 (INSTALL: INACTIVE LEAF) FINISH 613 1 KICK PLATE ROCKWOOD K1050 30 X 34" LDW US32D FINISH US10B (ACTIVE LEAF) 1 KICK PLATE ROCKWOOD K1050 30X 22" LDW US32D FINISH US10B (INACTIVE LEAF) 2 SET OF SEALS PEMKO 303AS84 (@5200) FINISH D 1 HEAD SEAL PEMKO 2891APK 60 FINISH D 1 THRESHOLD PEMKO HALF SADDLE 2005AV36 FINISH A 1 DOOR SWEEP PEMKO 3452DPK24" FINISH D 1 DOOR SWEEP PEMKO 3452APK36" FINISH A 1 RAIN DRIP PEMKO 346C64 FINISH D 1 DUST PROOF STRIKE ROCKWOOD 570 US10B FINISH US10B 1 PLASTIC SIGN: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". 2 SECURITRON DPS M BK SET No. 5 2 STANDARD HINGE MCKINNEY 1502 4 1/2” X 4 1/2" US26D 1 STANDARD HINGE MCKINNEY T4A3786 4 1/2” X 4 1/2” (NRP) US26D (INSTALL TOP HINGE) 1 LATCHSET YALE AU R 8802FL LH 626 IND 1 COAT HOOK ROCKWOOD 790 US26D 2 DOOR SILENCER ROCKWOOD 608 1. ALL EXITS TO BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY SPECIAL KNOWLEDGE. 2. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. 3. ALL DOOR HARDWARE IS TO BE ACCESSIBLE BY DISABLED PERSON. KAWNEER 451UT FRAMING SYSTEM OR EQUAL. 102A 101A WALK IN FREEZER 106 COLD VAULT 105 STORAGE ROOM 103 BACK ROOM 109 PREP AREA 110 CASHIER 108 HALLWAY 111 MEN'S RESTROOM 102 101B 103 SALES FLOOR 107 101C 101D 102B 108B108AABB WALK IN COOLER 104 CO2 BC S BC S EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EL E C T R I C A L PA N E L EXTERIOR ROOF ACCESS LADDER C WH C 1 107 WOMEN'S RESTROOM 101 KAWNEER TRIFAB 450 2" VENEER SYSTEM GLAZING TO BE MANUFACTURED ACCORDING TO STOREFRONT MANUFACTURER'S SPECIFICATIONS REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A6.0 PROJECT NUMBER: 24212 ROOM KEY PLAN, DOOR/ WINDOW SCHEDULE & TYPES, AND NOTES CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1/4" = 1' 0" 3WINDOW SCHEDULE 1/4" = 1' 0" 2DOOR TYPES 1/4" = 1' 0" 1FRAME TYPES HARDWARE NOTES DOOR SIGNAGE NOTES ACCESSIBILITY NOTES HARDWARE SCHEDULE STOREFRONT NOTES 1/8" = 1' 0" 4DOOR / WINDOWS / ROOM KEY PLAN GLAZING SCHEDULE D 1 1 ENTRY DOORS ABOVE ENTRY DOORS 0.27 3.7 0.25 0.57 SEE DOOR TYPES / WINDOW SCHED.1"SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4" LITES TEMPERED AS SHOWN ON ELEVATIONS. C1 1 RIGHT OF ENTRY DOORS 0.27 3.7 0.25 0.57 8' 4" 7' 4" 1" VENEER STOREFRONT SYSTEM 1/4" GLAZING (SPANDREL) MATCH STOREFRONT GLAZING FINISH C 1 RIGHT OF ENTRY DOORS 0.27 3.7 0.25 0.39/0.57 4' 4" 7' 4" 1" SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4" LITES TEMPERED AS SHOWN ON ELEVATIONS. B2 2 ENTRY DOORS 0.27 3.7 0.25 0.57 3' 0" 7' 0" 1" SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4" LITES TEMPERED. B1 2 ABOVE ENTRY DOORS 0.27 3.7 0.25 0.57 3' 0" 3' 1 3/4" 1" SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4" LITES B 2 LEFT & RIGHT OF ENTRY DOORS 0.27 3.7 0.25 0.57 12' 8" 7' 4" 1" SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4" LITES TEMPERED AS SHOWN ON ELEVATIONS. A 1 LEFT OF ENTRY DOORS 0.27 3.7 0.25 0.39/0.57 16' 10" 7' 4" 1" SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4" LITES TEMPERED AS SHOWN ON ELEVATIONS. WIDTH HEIGHT THKN. MARK QTY. GLAZING LOCATION SUMMER U FACTOR R VALUE SHGC PF SIZE NOTES DOOR SCHEDULE STOREFRONT VENEER 2' 0" 8' 0" 1 3/4" 111 HALLWAY 3' 0" 8' 0" 1 3/4"D5 INSUL. MTL. PAINT H.M. PAINT F3 4 11/A8.2 2/A8.2 1/A8.2 DOUBLE LEAF DOOR EXIT ONLY 109 BACK ROOM EXTERIOR 3' 0" 7' 0" 1 3/4" D3 INSUL. MTL. PAINT H.M. PAINT F1 3 11/A8.2 2/A8.2 1/A8.2 EXIT DOOR 107 BACK ROOM 3' 0" 7' 0" 1 3/4" D4 H.M. PAINT H.M. PAINT F1 2 7/A8.2 7/A8.2 10/A8.2 WITH 4"x24" TEMPERED ONE WAY GLASS WINDOW 103 STORAGE 3' 0" 7' 0" 1 3/4" D2 H.M. PAINT H.M. PAINT F1 2 7/A8.2 7/A8.2 10/A8.2 102B RESTROOM PART. 2' 4" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED 102A RESTROOM PART. 3' 0" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED 101D RESTROOM PART. 2' 4" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED 101C RESTROOM PART. 2' 4" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED 101B RESTROOM PART. 2' 10" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED 101A RESTROOM PART. 3' 0" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED 108B STOREFRONT 3' 0" 7' 0" D1 ALUM/GLASS BRONZE ALUM BRONZE 1 4/A8.2 4/A8.2 3/A8.2 SINGLE SWING 108A STOREFRONT 3' 0" 7' 0" D1 ALUM/GLASS BRONZE ALUM BRONZE 1 4/A8.2 4/A8.2 3/A8.2 SINGLE SWING WIDTH HEIGHT THKN. SIZE TYPE MATERIAL FINISH MATERIAL FINISH TYPE SET NO. HEAD JAMB SILLMARK ROOM NO. DOOR FRAME HDW. DETAILS REMARKS DOOR SCHEDULE METAL FLASHING TO MATCH ADJACENT WALL COLOR 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING 1/2" CONT. SEALANT 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER NICHIHA FIBER CEMENT PANEL NICHIHA 10MM SPACER FACE FASTENER, FOLLOW MFRS GUIDELINE FOR INSTALLTION STOREFRONT VENEER SYSTEM BASIS OF DESIGN: KAWNEER, TRIFAB 450 5/8" GYP. BD., SEE FINISH SCHEDULE INTERIOREXTERIOR SIP PANEL SYSTEM NOTE: METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. SEE FINISH SCHEDULE SIP PANEL SYSTEM PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1" INSULATED DOUBLE PANED GLASS EXTERIOR INTERIOR 1/2" CONT. SEALANT, TYP. STOREFRONT VENEER SYSTEM BASIS OF DESIGN: KAWNEER, TRIFAB 450 SIP PANEL SYSTEM SEE FINISH SCHEDULE NOTE: 1. METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. 2. INSTALL NICHIHA SILL FIRST THEN WORK LEDGESTONE UP TO BOTTOM OF SILL. METAL FLASHING TO MATCH ADJACENT WALL COLOR KURASTONE CLIP MIN. OF (2) 8 SCREW PER CLIP KURASTONE PIECE CONT. SEALANT, TYP. STOREFRONT VENEER SYSTEM BASIS OF DESIGN: KAWNEER, TRIFAB 450 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER EXTERIOR GRADE PLYWOOD SHEATHING UPSIDE DOWN ULTIMATE HORIZONTAL STARTER TRACK (INSTALLED FIRST) KURASTONE SILL CHISELED ON UPSIDE DOWN SILL CHISELED CLIPS ON 5MM SPACER SILL CHISELED CLIP KURASTONE CLIP ATTACHED VERTICALLY CONTINOUS METAL FLASHING 4" MIN. VERTICAL INTERIOR EXTERIOR SEE FINISH SCHEDULE SIP WALL PANEL(S) SEE SIP PLANS FOR PANEL TO PANEL CONNECTIONS LINE OF SILL CHISELED CAP BELOW (JAMB) ULTIMATE CLIP, FOLLOW MFRG. FOR INSTALLATION 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER NICHIHA J MOLD METAL TRIM CONT. SEALANT, TYP. STOREFRONT VENEER SYSTEM BASIS OF DESIGN: KAWNEER, TRIFAB 450 PRE FINISHED ALUMINIUM STOREFRONT FRAMING WITH 1" SINGLE PANED SPANDREL GLASS NICHIHA FIBER CEMENT PANEL REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A6.1 PROJECT NUMBER: 24212 EXTERIOR ARCHITECTURAL DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3" = 1' 0" 1STOREFRONT VENEER HEAD 3" = 1' 0" 2STOREFRONT VENEER JAMB 3" = 1' 0" 3STOREFRONT VENEER SILL 3" = 1' 0" 4STOREFRONT VENEER JAMB 3' 1 3/4" T.O. WAINSCOTT CAP B.O. BOX AT 6' 0" AFF PER FIRE DEPT. VARIES PER ELEV. T.O.PARAPET CONTINUOUS 26 GA. 8" HIGH GSM FLASHING. BOTTOM EDGE TO EXTEND MIN. 4" BELOW FLOOR SLAB. SET IN FULL BED OF MASTIC. PAINT EXPOSED SURFACE TO MATCH FIBER CEMENT COLOR SIP WALL PANELS. SEE SIP SHEETS SEE FINISH PLANS SIP WALL PANEL SILL GASKET 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL ULTIMATE CLIP NICHIHA FIBER CEMENT PANEL 8" CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION ANCHOR BOLT, SEE STRUCT. SEE CIVIL AND LANDSCAPE MIN. DISTANCE TO HARD SURFACE WHERE OCCURS 4" NICHIHA STARTER FLASHING NICHIHA HORIZONTAL STARTER TRACK 1/4 " CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING SEE STRUCT. 3" 7" R 10 EDGE OF SLAB INSULATION CONTINUOUS 26 GA. 8" HIGH GSM FLASHING. BOTTOM EDGE TO EXTEND MIN. 4" BELOW FLOOR SLAB. SET IN FULL BED OF MASTIC. PAINT EXPOSED SURFACE TO MATCH FIBER CEMENT COLOR SIP WALL PANELS. SEE SIP SHEETS SEE FINISH PLANS SIP WALL PANEL SILL GASKET 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL ULTIMATE CLIP NICHIHA FIBER CEMENT PANEL 8" CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION ANCHOR BOLT, SEE STRUCT. SEE CIVIL AND LANDSCAPE MIN. DISTANCE TO HARD SURFACE WHERE OCCURS 4" NICHIHA STARTER FLASHING NICHIHA HORIZONTAL STARTER TRACK 1/4 " CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING SEE STRUCT. 3" R 10 EDGE OF SLAB INSULATION 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL KURASTONE CLIP KURASTONE PIECE NICHIHA FIBER CEMENT PANEL METAL FLASHING, SW TOTALLY TAN NICHIHA STARTER TRACK 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING FINISH WHERE APPLIES. SEE FINISH PLAN AND SCHEDULE SIP WALL PANEL. SEE SIP SHEETS NOTE: 1. METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. 2. INSTALL NICHIHA SILL FIRST THEN WORK LEDGESTONE UP TO BOTTOM OF SILL. UPSIDE DOWN ULTIMATE HORIZONTAL STARTER TRACK (INSTALLED FIRST) KURASTONE SILL CHISELED ON UPSIDE DOWN SILL CHISELED CLIPS ON 5MM SPACER SILL CHISELED CLIP KURASTONE CLIP ATTACHED VERTICALLY CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION CONTINUOUS 26 GA. 8" HIGH GSM FLASHING. BOTTOM EDGE TO EXTEND MIN. 4" BELOW FLOOR SLAB. SET IN FULL BED OF MASTIC. PAINT EXPOSED SURFACE TO MATCH FIBER CEMENT COLOR SEE CIVIL AND LANDSCAPE SIP WALL PANEL. SEE SIP SHEETS 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL NICHIHA FIBER CEMENT PANEL NICHIHA STARTER FLASHING SILL GASKET FINISH WHERE APPLIES. SEE FINISH PLAN AND SCHEDULE MIN. DISTANCE TO HARD SURFACE WHERE OCCURS ANCHOR BOLT, SEE STRUCT. NICHIHA HORIZONTAL STARTER TRACK FASTNER SPACING 12" O.C. 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING 3" 7" SEE STRUCT. 4" 8" R 10 EDGE OF SLAB INSULATION 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL NICHIHA CLIP NICHIHA FIBER CEMENT PANEL DOUBLE FLANGE SEALANT BACKER ATTACH DOUBLE PANEL FLANGE SEALANT BACKER TO SHEATHING REFER TO SIP SHEETS FOR PANEL CONNECTIONS. CONTINUOUS SEALANT SIP WALL PANEL SEE FINISH SCHEDULE WALL PANEL STONE PIECE KURASTONE CLIP 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL NICHIHA CLIP NICHIHA FIBER CEMENT PANEL DOUBLE FLANGE SEALANT BACKER ATTACH DOUBLE PANEL FLANGE SEALANT BACKER TO SHEATHING CONTINUOUS SEALANT REFER TO SIP SHEETS FOR PANEL CONNECTIONS. SIP WALL PANEL SEE FINISH SCHEDULE WATERPROOF SEALANT 1/4" MIN THICKNESS WITH BACKER ROD 5/8" GYPSUM BOARD SEE FINISH SCHEDULE CORNER BEAD, TYP. HEMMED METAL SILL FLASHING TO MATCH STOREFRONT COLOR SEALANT BOTH SIDES 1/4" WOOD SHIM AS REQUIRED 4 1/2" SIP WALL PANEL. SEE SIP SHEETS SEALANT UNDER FLASHING NOTE: 1. METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. 2. INSTALL NICHIHA SILL FIRST THEN WORK LEDGESTONE UP TO BOTTOM OF SILL. EXTERIORINTERIOR PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1" INSULATED DOUBLE PANED GLASS (TYP.) UPSIDE DOWN ULTIMATE HORIZONTAL STARTER TRACK (INSTALLED FIRST) KURASTONE CLIP ATTACHED VERTICALLY KURASTONE CLIP 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL KURASTONE PIECE KURASTONE SILL CHISELED ON UPSIDE DOWN SILL CHISELED CLIPS ON 5MM SPACER SILL CHISELED CLIP PER FOOT SLOPE 1/4" SIP WALL PANEL FINISH WHERE APPLIES. SEE FINISH PLAN BLOCKING AS REQUIRED. SEE SIP VENDOR SHEETS SIP WALL PANEL 1/4" CHALKING WITH BACKER ROD 1/4" CHALKING WITH BACKER ROD PROVIDE 26 GA. GSM FLASHING ALL AROUND 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OUTLINE OF KNOX BOX NICHIHA FIBER CEMENT PANEL NICHIHA 10MM SPACER BLOCKING AS REQUIRED. SEE SIP VENDOR SHEETS METAL FLASHING FASTENER AND SPACER FACE FASTENER TOGGLE BOLT BY SIP VENDOR (SPACING AT ACCESS DOOR ONLY) 26" O.C. WOOD CEILING JOIST OR TRUSS WOOD SCREW WOOD CEILING JOIST, OR TRUSS WOOD SCREWS IN HINGES 2x BLOCKING BEYOND LOCK SOFFIT FINISH TYPE, PER REFLECTED CEILING PLAN SOFFIT FINISH TYPE, PER REFLECTED CEILING PLAN TRIMLESS FLUSH MOUNTED ACCESS DOOR, PAINTED TO MATCH ADJACENT CEILING (SPACING AT ACCESS DOOR ONLY) 26" O.C. CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION CONTINUOUS 26 GA. 8" HIGH GSM FLASHING. BOTTOM EDGE TO EXTEND MIN. 4" BELOW FLOOR SLAB. SET IN FULL BED OF MASTIC. PAINT EXPOSED SURFACE TO MATCH FIBER CEMENT COLOR SEE CIVIL AND LANDSCAPE SIP WALL PANEL. SEE SIP SHEETS 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL KURASTONE CLIP KURASTONE PIECE NICHIHA STARTER FLASHING SILL GASKET FINISH WHERE APPLIES. SEE FINISH PLAN AND SCHEDULE MIN. DISTANCE TO HARD SURFACE WHERE OCCURS ANCHOR BOLT, SEE STRUCT. NICHIHA HORIZONTAL STARTER TRACK FASTNER SPACING 12" O.C. 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING 3" 7" SEE STRUCT. 4" 8" 1/2" R 10 EDGE OF SLAB INSULATION 12" WIDE 20 GA. GALV. ANCHOR CLIPS 3' 0" O.C. 8" WIDE CONCEALED SPLICE PLATE AT EACH JOINT PRE FINISHED METAL COPING COVER, 12" LENGTHS SLOPE 3/4" PER FOOT NICHIHA FIBER CEMENT PANEL CLIP FASTENED ON STUD FACE FASTENER SPACER WOOD BLOCKING, AS REQ 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER EXTERIOR GRADE PLYWOOD SHEATHING TPO ROOFING TO CONTINUE UNDERNEATH OF METAL COPING AND RUNNING VERTICALLY DOWN FACE BEHIND CLEAT. INSTALL PER MFR REQUIREMENTS SIP WALL PANEL. SEE SIP VENDOR DRAWINGS METAL FLASHING CONT. SEALANT SEALANT, TYP. 6 5/8" 1" 6" #9 X 1 1/2" STAINLESS STEEL FASTENER (PROVIDED), TYP. 3 1/2" 1' 0 " 7" 3 1 / 2 " 1 1 / 2 " REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A8.1 PROJECT NUMBER: 24212 ARCHITECTURAL DETAILS (EXTERIOR) CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3" = 1' 0" 12BASE SILL DETAIL FOR FRONT ELEVATION 3" = 1' 0" 11PERIMETER INSULATION DETAIL 3" = 1' 0" 9TRANSITION DETAIL 3" = 1' 0" 10BASE SILL DETAIL FOR REAR AND SIDE ELEVATION 3" = 1' 0" 7TYP. TRANSITION DETAIL PLAN 1 1/2" = 1' 0" 4NOT USED 3" = 1' 0" 5TYP. CONTROL/EXPANSION JOINT DETAIL 3" = 1' 0" 6WINDOW SILL DETAIL 3" = 1' 0" 1RECESS BOX DETAIL 3" = 1' 0" 2CEILING ACCESS PANEL 3" = 1' 0" 8BASE SILL DETAIL FOR FRONT ELEVATION 1 1/2" = 1' 0" 3PARAPET DETAIL DOOR W/ PAINT FINISH, SEE DOOR SCHEDULE HOLLOW METAL DOOR FRAME BEYOND WEATHER STRIPPING HALF SADDLE ALUMINUM THRESHOLD, SEE SPECS FLOORING AS SCHEDULED CONCRETE SLAB, SEE STRUCT. TOP OF CONC. 1:2 SLOPE, MAX. 1/2" EXPANSION MATERIAL 1/ 4 " 1/ 4 " 1/ 2 " M A X . 1" TEMPERED SAFETY GLAZING DOOR FRAME, FNISH TO MATCH STOREFRONT WEATHER STRIPPING HALF SADDLE ALUMINUM THRESHOLD SET IN A CONT. SEALANT BED TOP OF CONCRETE FLOORING AS SCHEDULED 2:1 MAX 1/ 4 " 1/ 4 " 1/ 2 " M A X 1/2" MAX THRESHOLD, SET IN FULL BED OF MASTIC 1/2" PRE MOLD EXPANSION JOINT WITH SEALANT 4 1/2" 2" PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1" INSULATED DOUBLE PANED GLASS DOOR METAL STOP DOOR FRAME, FINISH TO MATCH STOREFRONT 1" THICK TEMPERED GLASS DOOR (INTERIOR)(EXTERIOR) 2" 1/2" OVERLAP (TYP.) . . DOUBLE 3 5/8" METAL STUDS AT JAMB, TYP. TILE FINISH WHERE APPLICABLE 6" SEE PLAN FOR WALL TYPE SEALANT, TYP. TILE FINISH WHERE APPLICABLE JAMB ANCHOR (SINGLE SWING) PRE FINISHED ALUMINUM STOREFRONT SYSTEM PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1' INSULATED DOUBLE PANED GLASS (VERTICAL) 4 1/2" 2" PRE FINISHED ALUMINUM STOREFRONT SYSTEM (HORIZONTAL) 4 1 / 2 " PRE FINISHED ALUMINUM STOREFRONT SYSTEM WITH 1" INSULATED DOUBLE PANED GLASS INTERIOR DOOR PER DOOR SCHEDULE 1/ 2 " FLOOR FINISH PER FIN.SCHEDULE CHANGE FLOOR FINISH AT CENTRLIINE OF DOOR H.M. FRAME BEYOND (PAINT) TRANSITION STRIP CONC. FLOOR SLAB (SINGLE SWING) 4 1/2" 2" NICHIHA FIBER CEMENT PANEL METAL FLASHING, COLOR TO MATCH TOTALLY TAN NICHIHA 10MM SPACER 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL SEALANT WITH BACKER ROD FACE FASTENER 1 5 / 8 " INTERIOREXTERIOR 5/8" GYP. BD., SEE FINISH SCHEDULE GLULAM BEAM, SEE SIP SHEETS 1/4" SHIMS AS REQUIRED ALUMINUM STOREFRONT SYSTEM CORNER BEAD, TYP. CONT. SEALANT PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1" INSULATED DOUBLE PANED GLASS 2"5/8" 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL SIP WALL PANEL TILE WHERE APPLICABLE CONT. SEAL CONT. EACH SIDE KURASTONE WALL PANEL WAINSCOT. INSTALL PER MFR. REQUIREMENTS. CLIP AT VERTICAL JOINTS AND WITHIN 3" OF TERMINATION EDGES DOOR, SEE DOOR SCHEDULE EXTERIOR INTERIOR 1/4" BACK BEND (TYP.) SHIM AS REQUIRED HOLLOW METAL FRAME, PROVIDE MIN. OF 3 ANCHORS L ANGLE EDGING TO BE PROVIDED BY G.C. LINE OF SILL CHISELED CAP ABOVE. INSTALL PER MFR. REQUIREMENTS. 2" 5/ 8 " 1/ 4 " NICHIHA FIBER CEMENT PANEL METAL FLASHING 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL OSB SHEATHING SEALANT WITH BACKER ROD ALUMINUM EXTRUDED RAIN DROP GUARD NOTE: METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. NICHIHA 10MM SPACER FACE FASTENER INTERIOREXTERIOR SEE FINISH SCHEDULE 2X WOOD BLOCK, SEE SIP VENDOR SHEETS CONT. SEALANT SIP WALL PANEL HOLLOW METAL FRAME, PROVIDE MIN. OF 3 ANCHORS DOOR, SEE DOOR SCHEDULE 4 1 / 2 " 2"EXTERIOR INTERIOR NICHIHA FIBER CEMENT PANEL SEALANT BOTH SIDES SEE FINISH SCHEDULE SIP WALL PANEL 1/4" SHIMS AS REQUIRED ALUMINUM STOREFRONT SYSTEM ULTIMATE CLIP CORNER BEAD, TYP. NICHIHA J MOLD METAL TRIM LINE OF SILL CHISELED CAP BELOW (JAMB) 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1" INSULATED DOUBLE PANED GLASS 2"5/8" 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL SIP WALL PANEL TILE WHERE APPLICABLE CONT. SEAL CONT. EACH SIDE NICHIHA FIBER CEMENT PANEL ULTIMATE CLIP DOOR, SEE DOOR SCHEDULE EXTERIOR INTERIOR 1/4" BACK BEND (TYP.) SHIM AS REQUIRED HOLLOW METAL FRAME, PROVIDE MIN. OF 3 ANCHORS NICHIHA J MOLD METAL TRIM LINE OF SILL CHISELED CAP BELOW. INSTALL PER MFR. REQUIREMENTS. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A8.2 PROJECT NUMBER: 24212 ARCHITECTURAL DETAILS (EXTERIOR/INTERIOR) CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3" = 1' 0" 1THRESHOLD AT EXERIOR DOOR 3" = 1' 0" 3THRESHOLD AT STOREFRONT DOOR 3" = 1' 0" 4HEAD AT STOREFRONT (JAMB SIM.) 3" = 1' 0" 7INTERIOR DOOR JAMB (HEAD SIM.) 3" = 1' 0" 8NOT USED 3" = 1' 0" 9MULLION DETAIL 3" = 1' 0" 10INTERIOR DOOR THRESHOLD 3" = 1' 0" 12ALUMINUM WINDOW HEAD 3" = 1' 0" 2JAMB AT H.M. DOOR 3" = 1' 0" 11H.M. DOOR HEAD DETAIL 3" = 1' 0" 6ALUMINIUM WINDOW JAMB DETAIL 3" = 1' 0" 5JAMB AT H.M. DOOR VARIES PER ELEV. T.O. PARAPET +12' 2" B.O. SOFFIT NOTE: G.C. TO PROVIDE HILTI "SMOKE AND ACOUSTIC SEALANT CP 506" AT THROUGH/ PIPING/ DUCTWORK PENETRATIONS OF DRAFT STOP. PLYWOOD SHEATHING 2 10d EACH STUD MANUFACTURED TRUSSES PER PLANS 2x4 @ 16" O.C. FLAT MIN. 1/2" THK. GYPSUM BOARD DRAFTSTOP 2 10d EACH STUD GYP. BOARD OR TILE CEILING FINISH CONTINUOUS BEAD OF SEALANT STAINLESS STEEL CLAMPING RING PIPE PREMOLDED TPO PIPE FLASHING FASTENERS W/ PLATE @12" O.C. CONTINUOUS WELD EDGE SEALANT SIP ROOF PANEL TPO MEMBRANE ROOFING 1" TYP. 12 " M I N . PRESSURE TREATED WOOD NAILER INTERIOREXTERIOR ALUMINUM STOREFRONT SYSTEM 3" VTR PER PLUMBING INNER SECTION OF 2 PIECE PRE FINISHED PIPE CHASE ACOUSTICAL ADHESIVE FOAM TAPE W/ SEALANT EACH SIDE OUTER SECTION OF 2 PIECE PRE FINISHED PIPE CHASE 4 1/2" (VERTICAL) PRE FINISHED ALUM. STOREFRONT SYSTEM PRE FINISHED ALUMINUM STOREFRONT FRAMING WITH 1" INSULATED DOUBLE PANED GLASS 2 PIECE PRE FINISHED ALUMINUM PIPE CHASE 3" VTR PER PLUMBING LINE OF WALL BELOW ACOUSTICAL ADHESIVE FOAM TAPE SEALANT EACH SIDE 5" 8" 4 1 / 2 " 8" M I N . A B O V E H I G H E S T AD J A C E N T R O O F S U R F A C E 4" NOTE: 1. FLASHING REQ'TS SHALL BE VERIFIED W/ UNIT TYPE BEFORE FABRICATION. ROOFING MEMBRANE 1/2" THICK. 1" WIDE TAPE SEALANT, CONT., TOP & BOTTOM OF FLASHING CONT. GALV. METAL FLASHING, VERIFY SHAPE WITH UNIT DESIGN PRE FAB MTL. CURB W/ WD. NAILER AND INSULATION, CURB SHALL OFFSET ROOF SLOPE INSULATION CRICKET AT UPHILL SIDE, 4" MIN. RISE, SEE DETAIL 4/A8.3 MECH. UNIT ATTACH TO CURB PER MANUF. REQUIREMENTS CONT. SEALANT FRAMING, SEE SIP SHEETS FLASHING MEMBRANE, SEE DETAIL 10/A8.3 SIP ROOF PANEL TPO BONDING ADHESIVE TPO MEMBRANE WIDE WELDED SPLICETPO BONDING ADHESIVE TPO ROOFING TO CONTINUE TO UNDERNEATH OF METAL COPING. INSTALL PER MFR REQUIREMENTS SIP WALL PANEL. SEE SIP VENDOR SHEETS SIP ROOF PANEL HD OR HD PLUS SEAM PLATE AND ROOF SYSTEM FASTENER AT 12" O.C. MAX. 6"MAX. MIN. 1/2" 1/4" COVER BOARD GC NOTE: DETAIL WILL CHANGE BASED ON TPO SPECIFICATION. REFLECT COVER BOARD PER TPO REQUIREMENTS. 12 " T Y P . 1 2 " T Y P . 9 3_8" 4" 1' 6" 9 3 / 8 " 2"x3/8" BENT BAR AT 1/3 POINTS, BOTH SIDES, PAINTED LINE OF WALL 2"x3/8" STEEL BAR, PAINTED #6 REBAR AT 12" O.C. VERTICAL, PAINTED 3/8"x3" EXPN. BOLT TO FLOOR, PAINTED 2"x3/8" STEEL BAR, WELD TO UP RIGHT AND EXP. BOLT TO FLOOR, PAINTED #6 REBAR AT 12" O.C. VERTICAL, PAINTED 2"x3/8" STEEL BAR, WELD TO UP RIGHT AND EXP. BOLT TO FLOOR LINE OF WALL 5" GUTTER BEYOND. SEE 9/A8.3 4" A SECTION 'A' (PLAN) CL CL SIDE SECTION AFFL 3/8" DIA. STAINLESS OR GALV. THREADED ROD W/ WASHERS, INCLUDE 3/4" OD TUBE AS CRUSH SLEEVE . REFER TO SIP VENDOR DWGS. 3/8" DIA. STAINLESS OR GALV. THREADED ROD W/ WASHERS, INCLUDE 3/4" OD TUBE AS CRUSH SLEEVE . REFER TO SIP VENDOR DWGS. ROOFING MEMBRANE WALL OR CURB OPENING TAPERED INSULATION TAPERED INSULATION SIP ROOF PANEL TPO ROOFING MEMBRANE 10 " NOTE: METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. 6 5/8" SIP PARAPET/ WALL PANEL. SEE SIP PLANS. SLOPE 3/4" PRE FINISHED SNAP ON METAL FASCIA, COUNTER FLASHING, RE: EXT. ELEVATIONS PER FOOT NICHIHA FIBER CEMENT PANEL FACE FASTENER SPACER CLIP FASTENED ON STUD 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER EXTERIOR GRADE SIP WALL PANEL WOOD BLOCKING AS REQUIRED TPO ROOFING TO CONTINUE UNDERNEATH OF METAL FASCIA AND RUNNING VERTICALLY DOWN FACE BEHIND CLEAT. INSTALL PER MFR REQUIREMENTS NICHIHA FIBER CEMENT PANEL 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER OSB SHEATHING OVERHANG FLASHING BY NICHIHA VENDOR 2X BLOCKING, SEE SIP VENDOR SHEETS NICHIHA FIBER CEMENT PANEL, TUFF BLOCK, COLOR TO MATCH TOASTY SW#6095 FASTENER SPACER NICHIHA FIBER CEMENT PANEL SEALANT 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER FACE FASTENER 1/4" REQUIRED CLEARANCE PRE MANUFACTURED WOOD TRUSS. SEE SIP VENDOR SHEETS NICHIHA 10MM SPACER 1/ 4 " NICHIHA 10MM SPACER 4" WIDE x CONT. SOFFIT VENT, W/CORROSION RESISTANT METAL MESH W/1/4" MAX. OPENINGS, SEE REFLECTED CEILING PLAN FOR LENGTHS, LOCATIONS. PAINT TO MATCH SOFFITREFER TO FASTENING REQUIREMENTS FOR SOFFIT APPLICATION IN THE INSTALLATION GUIDELINE NICHIHA FIBER CEMENT PANEL WOOD BLOCKING, TYP. THRU WALL METAL EMERGENCY OVERFLOW SCUPPER, PROVIDE FLASHING AT OPEN ENDS. SEE EXT. ELEV. FOR PAINT COLOR SIP WALL PANEL ROOFING MEMBRANE OVER PLYWOOD SHEATHING EXT. GRADE PLYWOOD WOOD BLOCKING, TYP. SIP ROOF PANEL PROVIDE CLOSURE FLANGE SURROUND, SEAL AT PERIMETER. SEE EXT. ELEV. FOR PAINT COLOR PROVIDE CLOSURE FLANGE SURROUND, SEAL AT PERIMETER. SEE EXT. ELEV. FOR PAINT COLOR WOOD BLOCKING AS REQUIRED 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER, TYP. NICHIHA 10MM SPACER CLIP FASTENED ON STUD FACE FASTENERWOOD TRUSS 1_4" REQUIRED CLEARANCE REFER TO SHEET METAL & AIR CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION "SMACNA" DETAILS FOR OVERFLOW INSTALLATION FLANGE TO OVERLAP 1/4" WITH FIBER CEMENT FACE FASTENER SIP WALL PANEL 1/ 4 " 8" 1/ 4 " 2" 2X WOOD BLOCKING, TYP. SIP ROOF PANEL SIP WALL PANEL 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER, TYP. CLIP FASTENED ON STUD FACE FASTENER LEADER BOX, SEE PLUMBING DWGS. PT WOOD BLOCKING,TYP.THRU WALL METAL SCUPPER, SEE EXT. ELEV. FOR PAINT COLOR SIP WALL PANEL ROOFING MEMBRANE OVER PLYWOOD SHEATHINGWOOD BLOCKING AS REQUIRED NICHIHA 10MM SPACER NICHIHA FIBER CEMENT PANEL FACE FASTENER 10" 1/ 4 " 1/ 4 " 8" 10" 10 " 5" 4" REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A8.3 PROJECT NUMBER: 24212 EXTERIOR ARCHITECTURAL DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1 1/2" = 1' 0" 1DRAFT STOP 1 1/2" = 1' 0" 8SMALL PIPE PENETRATION 3" = 1' 0" 5ALUMINIUM WINDOW HEAD DETAIL 3" = 1' 0" 6MULLION DETAIL 1 1/2" = 1' 0" 11ROOF CURB DETAIL 6" = 1' 0" 10SINGLE PLY ROOFING AT PARAPET WALL 1 1/2" = 1' 0" 7ROOF LADDER DETAIL 6" = 1' 0" 4TAPERED INSULATION CRICKET 1 1/2" = 1' 0" 3PARAPET DETAIL 3" = 1' 0" 2OVERHANG FLASHING DETAIL 1 1/2" = 1' 0" 12OVERFLOW SCUPPER DETAIL 1 1/2" = 1' 0" 9SCUPPER DETAIL 5' 2 1/2" A.F.F. 4' 2 1/2" A.F.F. 2' 9" A.F.F. EL. SEE PLAN EL. +7' 4" EL. +6' 6" EL. +4' 6" EL. SEE PLAN EL. ±7' 4" MENWOMEN GRADE 2 BRAILLE 3/4" SIZE LETTERS IN HELVETICA FONT ATTACH WITH 1/2" CARRIAGE BOLT WITH LOCKING NUT @ EA CORNER 8" 8" 2"2" 8" 8" CARE MUST BE TAKEN TO AVOID SUFFOCATION & ASPHYXIATION CO2 STORAGE AREA 2 NON-FLAMMABLE GAS 2187 3 0 0 SA 12"x10" SIGN FONT: ARIAL BLACK 11"x11" SIGN FONT: ARIAL BLACK 5.5"x5.5" SIGN FONT: ARIAL BLACK SQUARES: 2.75"x2.75" WHITE LETTERING (FONT SIZE: 1 1/2") BLUE VINYL SQ. (FONT SIZE: 1 1/2") WHITE LETTERING (FONT SIZE: 1 1/8") RED VINYL BLACK VINYL BLACK LETTERING (FONT SIZE: 5/8") BLACK LETTERING (FONT SIZE: 1/2") GREEN VINYL WHITE VINYL 1/8" BORDER GREEN VINYL WHITE LETTERING (FONT SIZE: 3/4") 1"x1" WHITE SQUARES w/ BLACK LETTERING (FONT SIZE: 3/4") RED VINYL SQ. (FONT SIZE: 1 1/2") YELLOW VINYL SQ. (FONT SIZE: 1 1/2") WHITE VINYL SQ. (FONT SIZE: 3/4") ALL LETTERING TO BE BLACK ON THIS SIGN SIP ROOF PANEL SYSTEM. SEE SIP VENDOR SHEETS 362S137 33 STEEL STUD BLOCKING AT 4' 0" O.C. WITH SIMPSON SFC EACH END 14 GA. CONTINUOUS BENT PLATE OR DEEP LEG 14 GA SLIP TRACK BY STUD MFR. ROOF FRAMING, SEE STRUCTURAL BLOCKING AT MID SPAN (TYP.) SUSPENDED ACOUSTICAL CEILING TILE 5/8" GYP. BD. TO ROOF STRUCTURE ON 3 5/8" 20 GA. METAL STUDS AT 16" O.C. (WHERE OCC.) (SEE FINISH SCHEDULE) 3 1/2" THK. ACOUSTICAL BATT INSULATION BOTTOM TRACK WITH .145 DIA. x 1 1/4" POWER DRIVEN FASTENER AT 24" O.C. PER ICC ESR 2269 FINISH FLOOR NOTE: 1. PROVIDE 1/2" PLYWOOD WITH 1/4" SHEET ROCK FOR FOUNTAIN WALL AT THE SIDE OF SALES AREA. #8 SMS EA. SIDE SE E P L A N SIP ROOF PANEL SYSTEM. SEE SIP VENDOR SHEETS 2 #10 X 1 1/2" SCREWS AT EACH JOINT OR BLOCK 14 GA. CONTINUOUS BENT PLATE OR DEEP LEG 14 GA SLIP TRACK BY STUD MFR. CONT. 16 GAUGE STEEL TRACK WITH 3 #10 TEK SCREWS AT EACH STUD AND #10 SCREWS AT 12" O.C. TO BLOCKING. 5 1/2" THK. ACOUSTICAL BATT INSULATION 2 #10 SCREWS AT EACH JOIST (ONE TOP, ONE BOTTOM) 5/8" GYP. BD. OVER 6" 20 GA METAL STUD AT 24" O.C. BLOCKING AT MID SPAN (TYP.) 5/8" GYP. BD. ON 6" OR 3 5/8" 20 GA. METAL STUDS AT 16" O.C. (SEE FINISH SCHEDULE) BOTTOM TRACK WITH .145 DIA. x 1 1/4" POWER DRIVEN FASTENER AT 24" O.C. PER ICC ESR 2269 BASE, SEE SCHEDULE FIN. FLR. SEE SCHEDULE NOTE: 1. PROVIDE MOISTURE RESISTANT GYPSUM BOARD FOR ALL RESTROOM WALLS. 10 A9.1 ______HSS 3"x3"x3/16" STEEL POST ATTACH STUD EACH SIDE TO POST W/ #12 TEX SCREW @ 16" O.C. SPACED VERTICALLY 5/8" MOISTURE RESISTANT GYP. BD. AT ALL RESTROOM WALLS TILE FINISH NOTE: ALL METAL STUDS MEET ESR 3064 REQUIREMENTS. 3 5/8" 20 GA METAL STUDS AT 16" O.C. METAL STUDS PER ICC ES ESR=3069P CERAMIC TILE IN THIN SET GROUT, TYP. 3 5/8" 20 GA. METAL STUDS AT 16" O.C. METAL STUDS PER ICC ES ESR 3069P 3 1/2" THK. ACOUSTICAL BATT INSULATION ROOF STRUCTURE 362S137 33 STEEL STUD BLOCKING AT 4' 0" O.C. WITH SIMPSON SFC EACH END 14 GA. CONTINUOUS BENT PLATE OR DEEP LEG 14 GA SLIP TRACK BY STUD MFR. ROOF FRAMING. SEE STRUCTURAL 14 GA. CONTINUOUS BENT PLATE OR DEEP LEG 14 GA SLIP TRACK BY STUD MFR. A. STUD PARALLEL TO TRUSS B. STUD PERPENDICULAR TO TRUSS 2 #10 X 1 1/2" SCREWS AT EACH JOINT OR BLOCK #8 SMS EA. SIDE ROOF STRUCTURE 2 #10 X 1 1/2" SCREWS AT EACH JOINT OR BLOCK ROOF FRAMING, SEE SIP SHEETS #8 SMS EA. SIDE 3 5/8" METAL STUD, BRACE AT EACH TRUSS 1" M I N . MI N . 1" C L E A R 1" M I N . MI N . 1" C L E A R SIP ROOF PANEL SYSTEM. SEE SIP VENDOR SHEETS CONT. SLIP TRACK w/ (2) #10 WOOD SCREWS TO TRUSS #8 SMS EA. SIDE 2 #10 SCREWS (ONE TOP, ONE BOTTOM) 5/8" GYP. BD. ON METAL STUDS (WHERE OCCURS). SEE FINISH SCHED. SUSPENDED A.C.T. OR GYP. BD. CEILING (WHERE OCCURS) 3 5/8" METAL STUDS PER ESR 2281 CONT. FLOOR TRACK WITH POWER DRIVEN ANCHOR AT 24" O.C. PER ICC ESR 2269 FIN. FLR. SEE SCHEDULE T/ STUD SE E P L A N MI N . 6" 7 A9.1 ______ 7B A9.1 ______ 7A A9.1 ______ 5/8" MOISTURE RESISTANT GYP. BD. OVER 6" 20 GA METAL STUD AT 24" O.C. SCHLUTER TRIM ON ALL INSIDE/OUTSIDE TILE CORNERS, TYP. 5/8" MOISTURE RESISTANT GYP. BD. BOTH SIDES. FRP TILES, BOTH SIDES, TOP AND BOTTOM. (SEE FINISH SCHEDULE, A1.11) POST BEYOND PORCELAIN TILE IN THIN SET GROUT. (SEE FINISH SCHEDULE) 3 5/8" STUDS AT 16" O.C. W/ TRACK T&B 362S162 33 & 362T150 33 BOXED T&B OF WALL. CLIP TO SUPPORTS W/ 2X2X12GAx3" LG ANGLES EA. END USING (3) #12 SCREWS EA. LEG SE E P L A N 1' 8 " ALUMINUM TRIM MOLDINGS (REFER TO FINISH SCHEDULE, A1.11) PAINT (REFER TO FINISH SCHEDULE, A1.11) MI N 6" MI N 6" SE E P L A N REFER TO DETAIL 8/A9.1 FOR CONNECTION 3 1/2" THK ACOUSTICAL BATT INSULATION CONT. 16 GA STEEL TRACK WITH 3 #10 TEK SCREWS AT EACH STUD AND #10 SCREWS AT 12" O.C. TO BLOCKING 2 #10 SCREWS (ONE TOP, ONE BOTTOM) 5/8" GYP. BD. TO 6" O.C. ON 3 5/8" 20 GA METAL STUDS AT 16" O.C. SUSPENDED ACOUSTICAL TILE CEILING (BOTH SIDES FOR PREP AREA ONLY) SEE FINISH SCHEDULE BOTTOM TRACK WITH .145 DIA x 1 1/4" POWER DRIVEN FASTENER AT 24" O.C. PER ICC ESR 2269 FIN. FLR. SEE SCHEDULE BASE. SEE SCHEDULE 5/8" GYP. BD. OVER 6" 20 GA METAL STUD AT 24" O.C. CEILING WHERE APPLICABLE BLOCKING AT MID SPAN (TYP.) NOTE: 1. PROVIDE MOISTURE RESISTANT GYP. BD. FOR ALL RESTROOM SIDE WALLS. 2. PROVIDE 6" 20 GA. METAL STUDS FOR BACKROOM WHERE PLUMBING IS NEEDED. SIP ROOF PANEL SYSTEM. SEE SIP VENDOR SHEETS 5/8" GYP. BD. ON 3 5/8" 20 GA METAL STUDS AT 16" O.C. (SEE FINISH SCHED). METAL STUDS PER ESR 2281 SUSPENDED ACOUSTICAL TILE CEILING 3 1/2" CAL BATT INSULATION BOTTOM TRACK WITH .145 DIA x 1 1/4" POWER DRIVEN FASTENER AT 24" O.C. PER ICC ESR 2269 FIN. FLR. SEE SCHEDULE BASE. SEE SCHEDULE CONT. SLIP TRACK w/ (2) #10 WOOD SCREWS TO TRUSS6" MI N 6" MI N T/ STUD #8 SMS EA. SIDE 5/8" MOISTURE RESISTANT GYP. BD. OVER 1/4" FRT PLYWOOD OVER HSS 3"x3"x3/16" STEEL POST CERAMIC TILE IN THIN SET GROUT, TYP. DETAIL B 3" 3" HSS 3" X 3" X 3/16" STEEL POST 5"X5"X3/8" THK. A36 STEEL PLATE DETAIL 'A' 3/16" 3/16" T/SLAB (4) #3 x 3 5/8" LG REBAR INSTALL W/ SET XP EPOXY3 5 / 8 " 2" 2 " 3 5/8" 20 GA. METAL STUD CERAMIC TILE SCHLUTER TRIM 5/8" MOISTURE RESISTANT GYP. BD. DOOR FRAME SHIMDETAIL C REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A9.1 PROJECT NUMBER: 24212 INTERIOR ARCHITECTURAL DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3" = 1' 0" 1RESTROOM SIGNS 1 1/2" = 1' 0" 2CO2 SIGN DETAILS 1" = 1' 0" 3SECTION AT WALL TYPE A 1" = 1' 0" 6SECTION AT WALL TYPE B 1" = 1' 0" 7RESTROOM PARTITION WALL (PLAN VIEW) 1" = 1' 0" 8TYPICAL STUDS CONNECTION DETAIL 1" = 1' 0" 9SECTION AT WALL TYPE C 1" = 1' 0" 10SECTION AT WALL TYPE F 1" = 1' 0" 11SECTION AT WALL TYPE E 1" = 1' 0" 12SECTION AT WALL TYPE D 1" = 1' 0" 4NOT USED 1" = 1' 0" 5NOT USED SEE RCP . VARIES B.O. ROOF DECK/STRUCTURE VARIES REFER TO CLG PLAN 10 '-10" A.F.F. 10 '6" A.F.F. SEE RCP A.F.F. SEE RCP A.F.F. SEE PLAN A.F.F. +10' 8" B.O. CEILING SEE ELEVATIONS B.O. LOFT +12' 2" B.O. TRUSS +10' 8" B.O. CEILING +5' 6" T.O. MTL STUD SUPPORT SEE ELEVATIONS B.O. SHELF 6" 3 5/8" 20ga. METAL STUD @ 16" O.C., TYP. 5/8" MOISTURE RESISTANT GYP. BD., TYPICAL WALK IN COOLER/FREEZER WALL #10 SHEET METAL SCREW X 3/4"" LONG @ 8" O.C. 3 5/8" 20ga TRACK W/#10 SHEET METAL SCREW X 3/4" LONG PER CONNECTION BOTH SIDES TYP. 1/2" MOISTURE RESISTANT GYP. BD. SCREWED IN WITH STAGGERED JOINTS & LEVEL 5 TAPING FINISH 3 5/8" X 20 GAGE STEEL STUDS AT 4' 0.C. WITH 2#10 SCREWS INTO SLIP TRACK, ATTACH STUD TO TOP CHORD WITH SFC2.25 SIMPSON CONNECTOR USING SDS SCREWS INTO WOOD TRUSSES ROOF STRUCTURE CONT. SLIP TRACK SFC CLIP ROOF FRAMING,SEE SIP SHEETS LINE OF SUSPENDED A.C.T. CEILING WALK IN COOLER/ FREEZER WALL 1/4" GYP. BD. SCREWED IN WITH STAGGERED JOINTS AND LEVEL 5 TAPING FINISH 3 5/8" 20 GA TRACK W/ #10 SHEET METAL SCREW x 3/4" LONG PER CONNECTION BOTH SIDES TYP. 3 5/8" 20 GA MTL TRACK 5/8" MOISTURE RESISTANT GYP. BD. TYPICAL 11 A9.2 ______ 11 A9.2 ______ 11 A9.2 ______ TYP 8" MAX TY P 8" M A X MA I N R U N N E R S 2' 0 " O . C . CROSS "T" MEMBERS 2' 0" O.C. GENERAL NOTES: 1. ENDS OF MAIN BEAMS AND CROSS TEES MUST BE TIED TOGETHER TO PREVENT THEIR SPREADING. 2. INSTALL CLG GRID USING #12 GA WIRE HANGERS @ 4 FT MAX O.C. & 8" MAX FROM PERIMETER WALL. 3. INTERMEDIATE DUTY GRID SYSTEM REQUIRED. 4. CEILING MUST HAVE OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHER PENETRATIONS. PROVIDE 3/8" MIN CLEAR ON ALL SIDES. 5. LIGHT FIXTURES (ALL TYPES) TO BE MECHANICALLY ATTACHED TO GRID PER NEC 410 16 (TWO 12 GA WIRES PER FIXTURE UNLESS INDEPENDENTLY SUPPORTED). AIR TERMINALS SUPPORT REQUIREMENTS: · <20 LBS POSITIVELY ATTACHED TO GRID · 20 TO 56 LBS POSITIVELY ATTACHED TO GRID AND TWO 12 GA WIRES TO STRUCTURE (MAY BE SLACK) · >56 LBS SUPPORTED DIRECTLY TO STRUCTURE BY APPROVED HANGERS 12 GA HANGER WIRE STABILIZER BAR MIN CLR 3/8" AT PERIMETER 8" MAX ℄ 1 1 / 2 " M A X 1 9 ± 1 0 ANGLE BRACKET OR CLIP. ATTACH PER MANUFACTURER RECOMMENDATIONS. 12 GA VERTICAL SUPPORT WIRE @ 4' 0" O.C. EA. WAY. AND MAX 8" FROM ALL EDGES. WIRE MUST NOT EXCEED A 1:6 SLOPE (±10) MINIMUM OF 3 RIGHT TURNS AT ALL WIRES INTERMEDIATE DUTY SUSPENDED GRID SYSTEM MAIN RUNNER @ 2' 0" O.C. INTERMEDIATE DUTY SUSPENDED GRID SYSTEM CROSS "T" MEMBER @ 2' 0" OR 4' 0" O.C. (REFER TO SPECIFIC CEILING TYPE) ACOUSTICAL CEILING TILES STABILIIZER BAR 7/8" MIN. WALL MOLDING WALL OR SOFFIT FRAMING AND FINISHES. REFER TO SPECIFIC DETAILS. NOTE: FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LOCAL BUILDING DEPARTMENT REQUIREMENTS, IF APPLICABLE. CONFORM TO BASIC MINIMUM REQUIREMENTS ESTABLISHED IN ASTM C636 & ASTM E 580. REFER TO DETAIL 10/A9.2 FOR CEILING LAYOUT REQUIREMENTS. 6" 6" 5/8" GYP. BD. TRUSS, SEE STRUCT. 3 5/8" STUDS X 20 GA. AT 16" O.C. SIP ROOF PANEL TRUSS TOP CHORD 3 5/8" x 18 GA. METAL BLKG. AT 16" O.C. LINE OF SUSPENDED A.C.T. CEILING 3 5/8" x 16 GA. ROLLED METAL TRACK. TYP. SUSPENDED ACOUSTICAL CEILING TILE, SEE RCP SOFFIT CONNECTION TO TRUSS FRAMING, SEE STRU. DWGS. 3 5/8" X 20 GA. METAL SOFFIT AT 16" O.C.EXT. WALL, SEE SIP VENDOR SHEETS ANGLE BREAK METAL TO CLOSE GAP, PAINT TO MATCH FRP FINISH 1/4" GYP. BD. SCREWED IN WITH STAGGERED JOINTS & LEVEL 5 TAPING FINISH FRP PANELING WHERE APPLICABLE SIP WALL PANEL. SEE FINISH SHEDULE WALK IN COOLER/FREEZER WALL SCREW TO FASTEN CAULK ON BOTH EDGES SCREW TO FASTEN EXT. WALL, SEE SIP SHEETS 2#10 TEK SCREW @ 8" O.C. TYP. 3 5/8" x 16 G.A. ROLLED METAL TRACK. TYP.3 5/8" X 20 GA. METAL SOFFIT AT 16" O.C. W/ 5/8" GYP. BD. ONE SIDE TRUSS, SEE SIP SHEETS SUSPENDED ACCOUSTICAL CEILING TILE, SEE RCP 3 5/8" STUDS X 20 GA. AT 16"O.C. SIP ROOF PANEL TRUSS TOP CHORD SOFFIT CONNECTION TO TRUSS FRAMING SEE STRU. DWGS. 6" REFER TO RCP 6" SOFFIT CONNECTION TO TRUSS FRAMING, SEE STRU. DWGS. TRUSS, SEE SIP SHEETS SIP ROOF PANEL TRUSS TOP CHORD WALL TYPE PER PLAN MOUNTED LED LIGHT SUSPENDED ACOUSTICAL CEILING TILE, SEE RCP WALL CONNECTION PER DETAIL 8/A9.1 WALL MOUNTED SOFFIT SYSTEM PROVIDED BY DECOR VENDOR HINGED PANEL OPENING BY DECOR VENDOR 1/2" PLYWOOD SHEATHING W/ 10d AT 6" O.C. INSTALL 1/2"∅ALL THREAD RODS @ ENDS, CORNERS AND WHERE SPAN EXCEEDS 5' 0" COUNTERSUNK WASHER (2"∅) & BOLT (MIN. 3 THREADS) 5/8" GYP. BD. W/ FRP FINISH CORNER BEAD 1 1/4" ALUM. ANGLE RECESS TO PLYWOOD FRP (WHERE OCCURS) 2"X4" NAILERS W/ 2 16d PER STUD 2' 0" 2 2"X4" NAIL W/ 10d @ 6" O.C. TRUSS, SEE SIP SHEETS CEILING PER PLANS TRUSS TOP CHORD SIP ROOF PANEL 3"X6" BLOCKING W/ SIMPSON A35 EA. END STAGGER EA. SIDE OF TRUSS. SEE SIP SHEETS L 2 1/2" X 2 1/2" X 4" LONG OF 1/4" THK. W/ 2 1/4"∅LAG SCREWS AT 2" O.C., 2" EMBED (EQUALLY SPACED) 1/2"∅ALL THREAD RODS, PROVIDE EMT TO COVER THREADS 2"X4" @ 16" O.C. W/ SIMP "LU" HANGER EA. END SIP WALL PANEL 2"X4" NAILER W/ 10d @ 6" O.C. (2 @ 6" O.C.) 2x DOUBLE TOP PLATE PER SIP FRP FINISH FRP FINISH MI N . G Y P 6" GC TO COORDINATE WITH CK CM FOR OPTIONAL LOFT DETAIL 12/A9.2 FOR PROJECT USE (2) 8" SIP THREAD POINT SCREW @ 6" O.C. MOP SINK CAULK INTERSECTION OF MOP BASIN AND FRP (ALL THREE SIDES) 362S137 43 METAL STUDS AT 12" O.C. 20 GA. CONT. BLOCK W/ #10x3/4" SELF TAPPING SCREWS TO EA. STUD. PEBBLE SURFACE MARLITE FRP PANELING, TO BOTTOM OF WATER HEATER SHELF, P 100 WHITE, OR EQUAL. 5/8" GYP. BD. EACH SIDE, TYP. PROVIDE W.R. GYP. BD. AT INTERIOR OF WALL 362S137 43 METAL STUD @ EACH END AND 12" O.C., TYP., ATTACH TO STUD W/ 4 #12 SCREWS, TYP. EA. END. 2" 24 GA STAINLESS STEEL RETURN 2"2" 24 GA. STAINLESS STEEL OVER 3/4" C.D.X. PLYWOOD TOP AND BOTTOM OF PLATFORM. SCREW PLYWOOD TO STUD W/ 1/4"x2 1/2" TEX SCREW AT 6" O.C. DRAIN PAN. SEE PLUMBING 20 GA. BLOCK, BEND AS REQUIRED AND ATTACH TO JOIST W/ 2 #12 EA. END. ELECTRIC WATER HEATER, SEE PLUMBING PLANS, 550 LBS CEILING PER PLANS 2"x20 GA. STRAP WATER HEATER TO METAL STUD OR BLOCKING W/ 3 #10 SCREWS OR PER MFR'S SPECIFICATIONS, TYP. NICHIHA FIBER CEMENT PANEL 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER EXTERIOR GRADE SIP WALL PANEL (2) 8" SIP THREAD POINT SCREW @ 6" O.C. SIP WALL PANEL OR METAL STUD WALL DEPENDING ON LOCATION FRP (WHERE OCCURS) (2) 8" SIP THREAD POINT SCREW @ 6" O.C. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A9.2 PROJECT NUMBER: 24212 INTERIOR ARCHITECTURAL DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1 1/2" = 1' 0" 5VALANCE AT WALK IN EQUIPMENT 3" = 1' 0" 6COOLER SIDE CLOSURE DETAIL 1/8" = 1' 0" 10ACT CEILING LAYOUT 3" = 1' 0" 11ACOUSTICAL CEILING TILE 1 1/2" = 1' 0" 9SOFFIT DETAIL 3" = 1' 0" 3BREAK METAL AT COOLER 1 1/2" = 1' 0" 8SOFFIT DETAIL 1 1/2" = 1' 0" 7SIGNAGE VALANCE @ CEILING 1 1/2" = 1' 0" 4STORAGE LOFT DETAIL 1" = 1' 0" 1SECTION THRU WATER HEATER/MOP SINK 1 1/2" = 1' 0" 12STORAGE LOFT DETAIL CONTINUOUS 26 GA. 8" HIGH GSM FLASHING. BOTTOM EDGE TO EXTEND MIN. 4" BELOW FLOOR SLAB. SET IN FULL BED OF MASTIC. PAINT EXPOSED SURFACE TO MATCH FIBER CEMENT COLOR SEE FINISH PLANS SILL GASKET 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL NICHIHA FIBER CEMENT PANEL SEE STRUCT. CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION ANCHOR BOLT, SEE STRUCT. SACKED EXPOSED FOUNDATION, PAINT TO MATCH FIBER CEMENT COLOR, TYP. NICHIHA STARTER FLASHING NICHIHA HORIZONTAL STARTER TRACK 1/4" CLEARANCE BETWEENEDGE OF PANEL AND FLASHING 3" M I N . R 10 EDGE OF SLAB INSULATION 1' 6 " FA C E O F P A N E L SEE SHEET A1.3 PLAN FOR DIMENSION (F.O.S.) 2 X 6 FRAMING PER SIP VENDOR WALL FINISH PER PLAN AND FINISH SCHEDULE SIP WALL PANELS FACE OF PANEL TO ALIGN WITH FDN. SLAB SIP WALL PANEL 2 X CORNER FRAMING PER SIP VENDOR SINGLE FLANGE SEALANT BACKER, TYP. SINGLE FLANGE SEALANT BACKER, TYP. NICHIHA FIBER CEMENT PANEL 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL ULTIMATE CLIP FACE OF PANEL TO ALIGN WITH STEM WALL FDN. TYP. WALL FINISH PER PLAN AND FINISH SCHEDULE 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL FIBER CEMENT CLIP KURASTONE LEDGESTONE SIP WALL PANELS 2 X CORNER FRAMING PER SIP VENDOR 1' 1 1/2" WALL FINISH PER PLAN AND FINISH SCHEDULE 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL FIBER CEMENT CLIP KURASTONE LEDGESTONE SIP WALL PANELS 2 X CORNER FRAMING PER SIP VENDOR CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION CONTINUOUS 26 GA. 8" HIGH GSM FLASHING. BOTTOM EDGE TO EXTEND MIN. 4" BELOW FLOOR SLAB. SET IN FULL BED OF MASTIC. PAINT EXPOSED SURFACE TO MATCH FIBER CEMENT COLOR SEE CIVIL AND LANDSCAPE SIP WALL PANEL. SEE SIP SHEETS 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL KURASTONE CLIP KURASTONE PIECE NICHIHA STARTER FLASHING SILL GASKET FINISH WHERE APPLIES. SEE FINISH PLAN AND SCHEDULE MIN. DISTANCE TO HARD SURFACE WHERE OCCURS ANCHOR BOLT, SEE STRUCT. SACKED EXPOSED FOUNDATION, PAINT TO MATCH FIBER CEMENT COLOR, TYP. NICHIHA HORIZONTAL STARTER TRACK FASTNER SPACING 12" O.C. 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING 3" 7" SEE STRUCT. 4" 8" 1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE BARRIER OVER SIP WALL PANEL KURASTONE CLIP KURASTONE PIECE NICHIHA FIBER CEMENT PANEL METAL FLASHING, SW TOTALLY TAN (MISSING PER CB 12 AND 12 R1) NICHIHA STARTER TRACK 1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING FINISH WHERE APPLIES. SEE FINISH PLAN AND SCHEDULE SIP WALL PANEL. SEE SIP SHEETS NOTE: 1. METAL FLASHING IN ALL AREAS TO BE PROVIDED AND INSTALLED BY G.C. 2. INSTALL NICHIHA SILL FIRST THEN WORK LEDGESTONE UP TO BOTTOM OF SILL. UPSIDE DOWN ULTIMATE HORIZONTAL STARTER TRACK (INSTALLED FIRST) KURASTONE SILL CHISELED ON UPSIDE DOWN SILL CHISELED CLIPS ON 5MM SPACER SILL CHISELED CLIP KURASTONE CLIP ATTACHED VERTICALLY REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC A9.3 PROJECT NUMBER: 24212 PILASTER DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 3" = 1' 0" 1BASE SILL DETAIL 1 1/2" = 1' 0" 3PILASTER DETAIL 1 1/2" = 1' 0" 2FRONT CORNER DETAIL 1 1/2" = 1' 0" 4CORNER DETAIL (KURASTONE) 3" = 1' 0" 5BASE SILL DETAIL (KURASTONE) 1 1/2" = 1' 0" 6TRANSITION DETAIL TYP. CA 03 TYP. CA 03 TYP. CA 04 TYP. CA 01 TYP. CA 03 TYP. CA 03 TYP. CA 02 TYP. CA 02 TYP. CA 02 TYP. CA 02 CA 05CA 05 _______ CA 2 1 _______ CA 2 2 _______ CA 2 3_______ CA 2 4 12' 0" TYP. 28' 0" TYP. 28' 0" TYP. 28' 0" TYP. 28' 0" TYP. 28' 0" 28' 0" 12' 0" C STORE SIDE STREET SIDE STREET SIDE 14 13 12 11 10 9 8 7 6 5 4 3 2 1 (28' OPTIMUM) (25' MINIMUM) 24 ' 0 " 192' 0" CD 01 TYP. CA 01 CD 01 TYP. CA 01 REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC CA 1 PROJECT NUMBER: 24212 FUEL CANOPY PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 985971/8" = 1' 0" 1FUEL CANOPY PLAN NUMBER DESCRIPTION CA 01 MULTI PRODUCT DISPENSER, SEE FUEL DRAWINGS CA 02 CONCRETE PAVING. SEE CIVIL SHEET & STRUCT. DRAWINGS CA 03 36" HIGH, 6" BOLLARD, QTY. 2 AT EACH END OF DISPENSER. REFER TO FUEL DRAWINGS CA 04 STEEL CANOPY COLUMN. SEE FUEL CANOPY STRUCTURAL DRAWINGS CA 05 LINE OF CANOPY ABOVE CD 01 MASTER DISPENSER, SEE FUEL DRAWINGS KEYNOTES X CB 01 CB 01 CB 01 CB 02 CB 03 CB 04 CB 03 C B A D E F T.O. FASCIA 15' 6" T.O. FASCIA 18' 6" CB 01 CB 01 CB 01 CB 02 CB 05 CB 04 CB 03 CB 06CB 06 C B A E F A B T.O. FASCIA 15' 6" T.O. FASCIA 18' 6" CB 06 CB 06 CB 01 CB 01 CB 01 CB 03 CB 03 CB 04 CB 05 A B B A C F D E T.O. FASCIA 15' 6" T.O. FASCIA 18' 6" CB 04 E CB 01 CB 01 CB 01 CB 03 CB 02 CB 03 CB 05 CB 04 A B C F D E T.O. FASCIA 15' 6" T.O. FASCIA 18' 6" CIRCLE K RED #PMS 485 CIRCLE K WHITE CIRCLE K ORANGE #PMS 144 SHERWIN WILLIAMS SW6236 GRAYS HARBOR PVC BOLLARD SLEEVE DARK GRAY RAL9016 SHELL WARM WHITE A B C D E F REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC CA 2 PROJECT NUMBER: 24212 FUEL CANOPY ELEVATIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1/8" = 1' 0" 1REAR ELEVATION (NORTH) 1/8" = 1' 0" 2FRONT ELEVATION (SOUTH) 1/8" = 1' 0" 3SIDE ELEVATION (EAST) 1/8" = 1' 0" 4SIDE ELEVATION (WEST) NOTES: 1. COLORS SHOWN ON THESE ELEVATIONS ARE FOR ILLUSTRATION PURPOSES ONLY. FOR ACTUAL COLORS, REFER TO MANUFACTURER'S SAMPLES. 2. THE FASCIA PANELS ARE PRE FINISHED BY SIGNAGE VENDOR 3. ALL SIGNS REQUIRE A SEPARATE SUBMITTAL. 4. ALL LIGHTING ON CANOPY TO BE FLUSH MOUNTED WITH FASCIA KEY NOTES FINISH SCHEDULE X X NUMBER DESCRIPTION CB 01 ACM PANEL "TEX COTE CB 02 COLUMN FLAGS BY SIGNAGE VENDOR CB 03 STEEL COLUMN WITH PAINT FINISH CB 04 6"0 BOLLARD, 36" HIGH CB 05 FUEL PUMP CB 06 INTERNALLY ILLUMINATED SIGN UNDER SEPARATE PERMIT 3"∅PVC DRAIN, BY FUEL CANOPY VENDOR LC OF COLUMN NOTE: SEE STRUCTURAL FUEL CANOPY SHEETS FOR SPECIFIC INFO. AND CANOPY ELEVATIONS FOR FINISH SCHEDULE. STEEL COLUMN, SEE ELEVATIONS AND STRUCT. FUEL CANOPY DWGS. STEEL COLUMN, PAINT W/ STUCCOFLEX, SEE EXT. ELEVATIONS FOR COLOR 2 CA 3 ______ CONCRETE FOOTING, SEE FUEL CANOPY STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION TOP OF DRIVE HEADER DECK, SEE STRUCT. FUEL CANOPY DWGS. STEEL COLUMN, PAINT W/ STUCCOFLEX, SEE EXT. ELEVATIONS FOR COLOR CONCRETE, SEE CIVIL NOTE: SEE STRUCTURAL FUEL CANOPY DWGS FOR SPECIFIC INFO. AND CANOPY ELEVS FOR FINISH SCHEDULE. STEEL COLUMN, SEE STRUCT. FUEL CANOPY DWGS. 11 CA 3 ______ CANOPY DWGS. SEE STRUCT. FUEL GENERAL NOTES 1. SEE STRUCTURAL FUEL CANOPY DWGS FOR MORE INFORMATION. 2. SEE EXTERIOR CANOPY ELEVATIONS FOR FINISH. REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 OTP 11/12/24 YELM, WA SS PC RM PC CA 3 PROJECT NUMBER: 24212 FUEL CANOPY COLUMN DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 1" = 1' 0" 1FUEL CANOPY COLUMN PLAN TYP. 1" = 1' 0" 2COLUMN SECTION @FUEL CANOPY TYP. 05/18/22 06/20/22