Circle K - Yelm (Yelm & Killion), WA - Architectural OTPABBREVIATIONS
& = AND
L = ANGLE
@ = AT
℄= CENTERLINE
∅= DIAMETER OF ROUND
# = POUND OR NUMBER
(E) = EXISTING
(R) = RELOCATED
(N) = NEW
A.B. = ANCHOR BOLT
A.F.F. = ABOVE FINISH FLOOR
AGGR. = AGGREGATE
AL. = ALUMINUM
APPROX. = APPROXIMATE
ARCH. = ARCHITECTURAL
ASPH. = ASPHALT
BD. = BOARD
BITUM. = BITUMINOUS
BLDG. = BUILDING
BLKG. = BLOCKING
BM. = BEAM
BOT. = BOTTOM
BW = BACK OF WALK
CAB. = CABINET
CEM. = CEMENT
CER. = CERAMIC
C.I. = CAST IRON
C.J. = CONTROL JOINT
CLG. = CEILING
CLR./CL. = CLEAR
COL. = COLUMN
CONC. = CONCRETE
CONSTR. = CONSTRUCTION
CONT. = CONTINUOUS
CTSK. = COUNTERSUNK
CNTR. = COUNTER
CTR. = CENTER
DEPT. = DEPARTMENT
DET. = DETAIL
DIA. = DIAMETER
DIM. = DIMENSION
DISP. = DISPENSER
DN. = DOWN
DR. = DOOR
D.S. = DOWNSPOUT
DWG. = DRAWING
E = EAST
EA. = EACH
EL. = ELEVATION
ELEC. = ELECTRICAL
EQ. = EQUAL
EXP. = EXPANSION
EXT. = EXTERIOR
F.F = FLOOR FINISH
FDN. = FOUNDATION
FG = FINISH GRADE
FIN. = FINISH
FL. = FLOOR
FLASH'G = FLASHING
FLUOR. = FLUORESCENT
F.O.C. = FACE OF CONCRETE
F.O.F. = FACE OF FINISH
F.O.S. = FACE OF SHEATHING
F.O.P. = FACE OF SIP PANEL
F.R.P. = FIBERGLASS
REINFORCED PANEL
F.S. = FLOOR SINK
FT. = FOOT OR FEET
FTG. = FOOTING
FURR. = FURRING
FUT. = FUTURE
G.A. = GAUGE
GALV. = GALVANIZED
GL. = GLASS
GR. = GRADE
GB = GRADE BREAK
GSM = GALVANIZED SHEET METAL
GYP. = GYPSUM
GYP.BD. = GYPSUM BOARD
H.B. = HOSE BIBB
HDWE. = HARDWARE
H.M. = HOLLOW METAL
HORIZ. = HORIZONTAL
HR. = HOUR
HGT. = HEIGHT
IE = INVERT ELEVATION
I.D. = INSIDE DIAMETER
INSUL. = INSULATION
INT. = INTERIOR
JT. = JOINT
LAM. = LAMINATE
LAV. = LAVATORY
LIP = EDGE OF SWALE OR GUTTER
MAX. = MAXIMUM
MECH. = MECHANICAL
MEMB. = MEMBRANE
MFR. = MANUFACTURER
MIN. = MINIMUM
MISC. = MISCELLANEOUS
M.O. = MASONRY OPENING
MTD. = MOUNTED
MUL. = MULLION
N. = NORTH
N.I.C. = NOT IN CONTRACT
NO. OR # = NUMBER
NOM. = NOMINAL
N.T.S. = NOT TO SCALE
O.C. = ON CENTER
O.D. = OUTSIDE DIAMETER
OPNG. = OPENING
OPP. = OPPOSITE
PB = LEVEL PAVEMENT AT
DISPENSER
PIT BOX
PL. = PLATE
P.LAM. = PLASTIC LAMINATE
PLYWD. = PLYWOOD
P.O.C. = POINT OF CURVATURE
P.O.S. = POINT OF SALE
R OR RAD. = RADIUS
R.D. = ROOF DRAIN
REF. = REFERENCE
REINF. = REINFORCED
REQ'D = REQUIRED
RM. = ROOM
R.O. = ROUGH OPENING
R.O.W. = RIGHT OF WAY
SCHED. = SCHEDULE
SECT. = SECTION
SHT. = SHEET
SIM. = SIMILAR
SIP = STRUCTURAL INSULATED
PANEL
SPEC. = SPECIFICATION
SQ. = SQUARE
S.ST. = STAINLESS STEEL
STD. = STANDARD
STL. = STEEL
STOR. = STORAGE
STRL. = STRUCTURAL
SYM. = SYMMETRICAL
T.C. = TOP OF CURB
TG = TOP OF GRATE
T.& G. = TONGUE & GROOVE
THK. = THICK
TI = TOP OF ISLAND
T.O. = TOP OF
TOW = TOP OF WALL
TP = TOP OF PAVEMENT
TS = TOP OF SLAB
TW = TOP OF WALK
TYP. = TYPICAL
UNF. = UNFINISHED
U.O.N. = UNLESS OTHERWISE
NOTED
VERT = VERTICAL
V.I.F. VERIFY IN FIELD
V.I.F. VERIFY IN FIELD
W/ = WITH
W.C. = WATER CLOSET
WD. = WOOD
W/O = WITHOUT
WP. = WATERPROOF
WSCT. = WAINSCOT
WT. = WEIGHT
PROJECT TEAM
OWNER
1122 W. WARNER RD.
TEMPE, AZ 85284
CIRCLE K STORES INC.
ATTN: JIM EDWARDS
TEL: (602) 721 6533
E MAIL: jim.edwards@circlek.com
ARCHITECT
11921 FREEDOM DR. #1110
RESTON, VA 20190
RETAIL DESIGN COLLABORATIVE
AOR: SEAN SLATER
ATT: RASHMI MEHADIA
CIVIL ENGINEER
1201 THIRD AVE, SUITE 2800
SEATTLE, WA 98101
KIMLEY HORN AND ASSOCIATES, INC.
ATT: LIZ WILLMOT, PE
TEL: (206) 677 8610
E MAIL: Liz.willomot@kimley horn.com
LANDSCAPE ARCHITECT
1201 THIRD AVE, SUITE 2800
SEATTLE, WA 98101
KIMLEY HORN AND ASSOCIATES, INC.
ATT: LIZ WILLMOT, PE
TEL: (206) 677 8610
E MAIL: Liz.willomot@kimley horn.com
STRUCTURAL ENGINEER
930 CENTRAL STREET
KANSAS CITY, MO 64105
JOHNSTON BURKHOLDER ASSOCIATES
BRIAN W. MAKOVEC
TEL: (816) 421 4200
E MAIL: makovec@baengr.com
ELECTRICAL ENGINEER
1805 N. 2ND ST. SUITE 5274
ROGERS, AR 72756
BENCHMARK GROUP
ATTN: JASON C. ADAMS P.E.
TEL: (479) 636 5004
E MAIL: jca@teamofchoice.com
MECH/PLUMB ENGINEER
1805 N. 2ND ST. SUITE 5274
ROGERS, AR 72756
BENCHMARK GROUP
ATTN: JASON M. SCATES, PE
TEL: (479) 636 5004
E MAIL: jms@teamofchoice.com
FUEL CANOPY STRUCT. ENGINEER
P.O. BOX F.
CASSIVILLE, MO 65625
AWNING COMPANIES
ATTN: STEVEN WILLIAMS SCHAUB
TEL: (417) 847 3131
TEL: (703) 659 8252
EMAIL: rashmi.mehadia@rdcollaborative.com
SUPER STRUCTURE ENGINEER
8180 CORPORATE PARK DR. SUITE 235,
CINCINNATI, OHIO 45242
PINNACLE ENGINEERING
ATT: MICHAEL STREICHER, PE
TEL: (513) 984 1663
E MAIL: projects@pinneng.com
PROJECT ADDRESS: NWC YELM AVENUE & KILLION ROAD, YELM WA 98597
PROJECT NAME: CIRCLE K CONVENIENCE STORE, FUEL & DIESEL PUMPS
PROJECT DESCRIPTION: PROPOSAL FOR A NEW CONVENIENCE STORE WITH ASSOCIATED FUEL SALES
CONSISTING OF A 5,200 S.F.CONVENIENCE STORE AND A 4,608 S.F.FUEL
CANOPY WITH [7]FUEL PUMPS. THE CONVENIENCE STORE WILL SELL BEER
& WINE FOR OFFSITE CONSUMPTION. THE FACILITY WILL OPERATE 24 HOURS.
PARCEL NUMBER:21724130100
PARCEL/SITE AREA:2.35 AC / ±102,366 S.F.
EXISTING ZONING:C 1 COMMERCIAL
GENERAL PLAN AND LAND USE DESIGNATION:COMMERCIAL
MAX. BUILD. HEIGHT:23' 0" PROVIDED (40' 0" ALLOWED)
MAX. CANOPY HEIGHT:18' 6" PROVIDED (55' 0" ALLOWED)
GROSS C STORE AREA: C STORE AREA: 5,200 S.F.
ENTRY CANOPY AREA; 218 S.F.
TOTAL GROSS C STORE AREA 5,418 S.F.
GROSS FUEL CANOPY: . . . . . . . . . . . . . . . .4,608 S.F.
TOTAL GROSS C STORE + FUEL CANOPY AREA . . . . . . . . . 10,026 S.F.
ALLOWABLE AREA (C STORE WITHOUT SPRINKLER) . . . . 9,000 S.F. (COMPLIES)
ALLOWABLE AREA (FUEL CANOPY WITHOUT SPRINKLER) . . 8,500 S.F. (COMPLIES)
GROSS LOT COVERAGE:
GROSS BLDG. AREA/SITE AREA: 5,418 S.F. / ±102,366 S.F. = 5.29 %
CONSTRUCTION TYPE (BUILDING): VB SPRINKLER IS NOT REQUIRED BY DEFAULT
CONSTRUCTION TYPE (FUEL CANOPY): II B SPRINKLER IS NOT REQUIRED BY DEFAULT
OCCUPANCY: M (MERCANTILE)BUILDING + CANOPY
PARKING REQUIRED: 5,200 SF/250 = 21 PARKING STALLS
(INCLUDING 1 REQ'D ACCESSIBLE STALL)
PARKING PROVIDED: 21 STALLS
(INCLUDING 1 ACCESSIBLE STALL)
BICYCLE PROVIDED:2 BICYCLE RACKS PROVIDED
LOADING PROVIDED: 3 TRUCK SPACES (14' X 58' 9")
CONVENIENCE STORE BUILDING AREA:
1. ACCESSORY STORAGE AREA, MECHANICAL EQUIPMENT ROOM.
A. AREA OF BACKROOM: = 571 S.F.
B. AREA OF UTILITY/STORAGE: = 103 S.F.
C. AREA OF WALK IN COOLER: = 803 S.F.
D. CASHIER & PREP AREA: = 454 S.F.
= 1,931 S.F.
2. SALES AREA: = 2,584 S.F.
3. AUXILL IARY AREAS (HALLWAY, RESTROOMS): = 685 S.F.
TOTAL BUILDING AREA: 5,200 S.F.
EXITING:
1. ACCESSORY STORAGE AREA, MECHANICAL EQUIPMENT ROOM: 1,931 S.F. /300 = 7 OCC.
2. SALES AREA 2,584 S.F. / 60 = 44 OCC.
3. AUXILIARY AREAS (HALLWAYS, RESTROOMS) 685 S.F. / 60 = 12 OCC.
TOTAL OCCUPANT LOAD = 63 OCCUPANTS
EXITS REQUIRED: 2
EXITS PROVIDED: 4
EGRESS WIDTH REQUIRED: 63 x 0.2 = 12.6"
EGRESS WIDTH PROVIDED: 34" X 3 + 42" X 1 = 144"
CODES USED: 2021 WASHINGTON STATE BUILDING CODE
2021 WASHINGTON STATE FIRE CODE
2021 WASHINGTON STATE MECHANICAL CODE
2021 WASHINGTON STATE PLUMBING CODE
2021 WASHINGTON STATE COMMERCIAL ENERGY CODE
2023 WASHINGTON STATE ELECTRICAL CODE, 2023 NFPA 70
2017 WASHINGTON STATE ACCESSIBILITY CODE, A117.1, 2017
PROJECT DATA
GENERAL BIDDING NOTES
1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION AND SUBMITTALS TO UTILITY COMPANIES FOR THIS
PROJECT.
2. CONTRACTOR SHALL PROVIDE UNIT PRICING TO OWNER ON ALL PHONE, GAS, TELECOMMUNICATION, AND POWER
COST FOR THIS PROJECT INCLUDING BUT NOT LIMITED TO TRENCHING, CONDUIT, LINE PULLS, CONNECTION, ETC.
3. CONTRACTOR SHALL BID THIS PROJECT COMPLETELY WITH NO EXCEPTIONS UNLESS INSTRUCTED BY OWNER.
CONTRACTOR SHALL PROVIDE ALLOWANCES ON ANY ITEM THAT CAN NOT BE RESOLVED DURING THE BID PROCESS.
4. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONNECTIONS, EXISTING PLUMBING TAPS, ELECTRICAL
PANEL LOCATIONS, GAS METERS AND MECHANICAL EQUIPMENT AGAINST THE PLANS AND REPORT ANY
DISCREPANCIES DURING THE BID PROCESS
5. CONTRACTOR SHALL BE RESPONSIBLE FOR CLARIFICATION OF DOCUMENTS. SHOULD A BIDDER FIND
DISCREPANCIES IN OR OMISSIONS FROM THE DRAWINGS OR DOCUMENTS, OR SHOULD HE BE IN DOUBT AS TO THEIR
MEANING, HE SHALL NOTIFY THE ARCHITECT FIVE DAYS OR MORE BEFORE DATE SET TO RECEIVE BIDS, WHO WILL
SEND, AFTER CONSIDERATION, IDENTICAL INSTRUCTIONS TO ALL BIDDERS. IN THE EVENT CLARIFICATION IS
DEEMED NECESSARY, NEITHER OWNER NOR ARCHITECT WILL BE RESPONSIBLE FOR ORAL INSTRUCTIONS.
6. GENERAL CONTRACTOR SHALL VERIFY GOVERNING REQUIREMENTS PRIOR TO BID AND ALL REQUIREMENTS FOR A
COMPLETE FIRE SPRINKLER SYSTEM ARE TO BE INCLUDED IN BID, IF BUILDING IS SPRINKLERED
7. THE ARCHITECT ASSUMES THE GENERAL CONTRACTOR HAS INCLUDED IN HIS BID/PRICING THE HIGHEST QUALITY
AND GREATEST QUANTITY FOR THE PURPOSE OF RESOLVING ANY CONFLICTS IN THE CONSTRUCTION DOCUMENTS
WHICH ARE IMPLIED OR UNDEFINED.
8. ALL BID NUMBERS SHOULD INCLUDE BREAKDOWN OF UNIT PRICE.
9. CONTRACTOR TO BASE BID ON PROVIDING 3 FIRE EXTINGUISHERS.
CLIMATE ZONE: 4C
GENERAL (PRESCRIPTIVE METHOD) C402.1 ITEM 2 C402.1; C402.2 & C402.1.3
PER TABLE C402.1.3 R VALUE BASED METHOD
ROOF INSULATION REQUIRED R30ci; PROVIDED R33ci
WOOD FRAMED EXTERIOR WALLS = REQUIRED R20; PROVIDED R24.7
UNHEATED SLABS REQUIRED R 10 FOR 24" BELOW; PROVIDED R 10 FOR 24" BELOW
PER TABLE C402.3 FOR SINGLE PLY SYSTEM:
TPO (THERMOPLASTIC POLYOLENM MEMBRANE) ROOFING SYSTEM OVER SIP ROOF PANEL. WHITE
MECHANICALLY FASTENED
SOLAR REFLECTANCE: .55
THERMAL EMITTANCE: .75
PER TABLE C402.4
U FACTOR STOREFRONT REQUIRED U 0.38; PROVIDED U 0.27
ENTRANCE DOOR REQUIRED U 0.77; PROVIDED U 0.27
OTHER DOORS REQUIRED U 0.45 ; PROVIDED U 0.27
STOREFRONT KAWNEER TRIFAB 451UT FRAMING SYSTEM OR EQUAL
1. COORDINATE ALL EQUIPMENT PLACEMENTS, SUPPORTS, AND CONNECTIONS WITH EQUIPMENT SUPPLIERS.
2. COMPLY WITH ALL LOCAL BUILDING CODES, ORDINANCES, AND CONSTRUCTION STANDARDS.
3. FOR COMPLETE MECHANICAL SYSTEM LOCATIONS AND SIZES OF SUPPLY, RETURN, AND DUCTWORK, SEE
MECHANICAL PLANS.
4. FOR COMPLETE ELECTRICAL SYSTEM LOCATIONS AND SIZES OF LIGHTING, OUTLETS, PHONES, AND
ELECTRICAL PANELS, SEE ELECTRICAL PLANS.
5. FOR COMPLETE PLUMBING LOCATIONS, SIZES, AND FIXTURE TYPES, SEE PLUMBING PLANS.
6. ALL NEW WALLS SHALL BE TAPED, TEXTURED, AND PAINTED PER OWNERS COLOR SELECTION /
SPECIFICATIONS.
7. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED.
8. ONE SET OF STAMPED, APPROVED DRAWINGS MUST BE MAINTAINED ON SITE AND MADE AVAILABLE TO CITY
INSPECTORS ON DEMAND.
9. ALL WORK SHALL BE FURNISHED AND INSTALLED IN COMPLIANCE WITH APPLICABLE BUILDING CODES AND
THE HIGHEST PROFESSIONAL WORKMANSHIP OF THE BUILDING TRADES PERFORMING UNDER THIS CONTRACT.
10. ALL REQUIRED CONTROLLED INSPECTIONS SHALL COMPLY WITH THE LOCAL BUILDING CODES.
11. ALL DIMENSIONS SHALL BE FIELD CHECKED, CHECKED IN SHOP, AND VERIFIED PRIOR TO THE PERFORMANCE
OF ANY WORK, AND THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES IN WRITING
BEFORE PERFORMANCE OF THE WORK.
12. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND SHALL BE RESPONSIBLE FOR THE
SCHEDULING OF THE WORK.
13. ELECTRICAL SYSTEMS SHALL BE INSTALLED PER N.E.C. AND IN ACCORDANCE WITH ALL APPLICABLE UTILITY
COMPANY SPECIFICATIONS AND MUNICIPAL JURISDICTIONAL CODES.
14. ALL PLUMBING AND ELECTRICAL PIPING CONDUIT SHALL BE CONCEALED EXCEPT AS OTHERWISE SPECIFIED.
15. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN
ENGINEER REGISTERED IN WASHINGTON STATE AND SUBMITTED TO THE ARCHITECT.
16. COORDINATION OF PLANS AND SPECIFICATIONS: THE GENERAL CONTRACTOR SHALL TAKE NO ADVANTAGE OF
ANY APPARENT ERROR OR OMISSION. HE SHALL IMMEDIATELY NOTIFY THE ARCHITECT, THE ARCHITECT WILL
THEN MAKE SUCH CORRECTIONS AND INTERPRETATIONS AS MAY BE DEEMED NECESSARY FOR FULFILLING
THE INTENT OF THE PLANS AND SPECIFICATIONS.
17. PROVIDE METAL ACCESS DOORS TO DUCTS AND OTHER MECHANICAL/ELECTRICAL EQUIPMENT THROUGH
SPACES, OR CEILINGS AS REQUIRED BY MECHANICAL/ELECTRICAL DRAWINGS AND THE APPLICABLE
REQUIREMENTS OF THE BUILDING CODES (BUILDING, MECHANICAL, ELECTRICAL).
18. PROPER STANDARDS OF CONSTRUCTION SHALL BE USED AS RECOMMENDED AS ACCEPTABLE STANDARDS IN
THE INDUSTRY FOR ALL CONSTRUCTION EVEN IF NOT SPECIFIED IN DETAIL.
19. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION.
20. PRIOR TO CONSTRUCTION, THE GENERAL CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR THE
CORRECTNESS OF ALL DIMENSIONS.
21. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE, LOCATE AND CONFIRM ALL
UNDERGROUND/ OVERHEAD PLUMBING AND ELECTRICAL STUB UPS.
22. GENERAL CONTRACTOR TO CAULK AND SEAL ALL EXPANS ION JOINTS AT ALL INTERIOR CONCRETE PRIOR TO
FLOORING.
23. ALL EXPOSED UNFINISHED METAL AND WOOD SHALL BE PAINTED AS PER SPECIFICATION, PAINT TO MATCH
ADJACENT COLOR.
24. GENERAL CONTRACTOR SHALL ENCLOSE, SEAL, AND COVER ALL PIPE, CONDUIT, DUCT, AND STRUCTURAL
PENETRATIONS IN ALL WALLS.
25. UNLESS OTHERWISE NOTED, DIMENSIONS ARE TO THE FACE OF MASONRY, FACE OF CONC. AND THE FACE OF
SHEATHING.
26. IN THE EVENT OF DISCREPANCIES BETWEEN ANY DRAWINGS AND/OR SPECIFICATIONS, THE MORE RESTRICTIVE
CONDITION SHALL BE DEEMED AS THE CONTRACT REQUIREMENT, UNLESS OTHERWISE STATED.
27. GENERAL CONTRACTOR TO MAINTAIN ROAD CLEANLINESS DURING CONSTRUCTION.
GENERAL NOTES
HEALTH DEPT. NOTES TO GC
1. WALK IN UNIT WALLS, CEILING, AND FLOOR/WALL JUNCTURES SHALL BE METAL OR EQUAL AND PROPERLY
COVED.
2. FLASH, TRIM, OR CAULK SPACES BETWEEN WALK IN UNIT AND ADJACENT WALLS.
3. WALK IN UNITS OR OTHER LARGE EQUIPMENT/SURFACES WITH SPACES 30 INCHES OR LESS IN HEIGHT BETWEEN
THE TOP SURFACES AND THE CEILING REQUIRE FLASHING OR CLOSING OFF IN A CLEAN, TIGHT VERMIN PROOF
MANNER.
4. ALL WOOD SHELVING OR WOODWORK SHALL BE SANDED SMOOTH, FREE OF OPEN JOINTS AND SEALED OR
PAINTED TO A SMOOTH, FINAL FINISH.
5. PROVIDE AN APPROVED SMOOTH, COVE BASE (3/8" RADIUS OR GREATER) AT WALL AND FLOOR JUNCTURES AND
EQUIPMENT BASES THROUGHOUT THE ESTABLISHMENT.
6. PROVIDE AN ADDITIONAL WATER LINE AT THE MOP SINK/UTILITY AREA TO SUPPLY CHEMICAL DISPENSERS. DO
NOT USE THE MOP SINK FAUCET. Y VALVES AND DOWNSTREAM SHUT OFF DEVICES ARE NOT PERMITTED ON SINK
FAUCETS OR CHEMICAL DISPENSERS.
7. ALL CONSTRUCTION SHALL MEET CURRENT COUNTY HEALTH CODE REQUIREMENTS.
CIRCLE K GENERAL NOTES
UNDER NO CIRCUMSTANCES WILL CIRCLE K ALLOW A CHANGE OF SUPERINTENDENTS DURING THE PROJECT(S).
DEFERRED SUBMITTALS
DEFERRED SUBMITTALS: (PER 2021 WBC)
DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL
IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM. G.C. WILL FORWARD DESIGN PROFESSIONAL'S APPROVED
DEFERRED SUBMITTAL TO THE BUILDING OFFICIAL FOR APPROVAL PRIOR TO INSTALLATION.A NOTATION
INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND HAVE BEEN FOUND TO BE IN
GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING SHALL BE MADE ON THE DEFERRED SUBMITTAL. THE
DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE
BEEN APPROVED BY THE BUILDING OFFICIAL.
DEFERRED SUBMITTAL ITEMS:
WOOD TRUSSES
SIGNAGE
SOIL TREATMENT
CONTRACTOR TO PROVIDE AN EPA REGISTERED TERMITICIDE COMPLYING WITH REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, IN AN AQUEOUS SOLUTION FORMULATED TO PREVENT TERMITE INFESTATION. PROVIDE
QUANTITY REQUIRED FOR APPLICATION AT THE LABEL VOLUME AND RATE FOR THE MAXIMUM TERMITICIDE
CONCENTRATION ALLOWED FOR EACH SPECIFIC USE, ACCORDING TO PRODUCT'S EPA REGISTERED LABEL.
PROJECT SITE
ELEVATION INDICATOR
REVISION MARK
KEYED NOTE
ROOM NUMBER IDENTIFICATION
CEILING HEIGHT
WALL SECTION
DOOR NUMBER IDENTIFICATION
INTERIOR PARTITION TYPE
WINDOW NUMBER IDENTIFICATION
DETAIL MARK
ROOM
NAME
XXX
DOOR
#
XX
XX
Sheet
X
#
#
Sheet
x' x"
x
SYMBOL LEGEND
CIRCLE K PROTOTYPE DATA
PROTOTYPE REVISION :5200 R3.4.1 05/16/23
CONSTRUCTION BULLETINS :
• 2305 COOLER RETAIL SHELVING
• 2306 FLOOR TILE VE
• 2309 TPO SPECIFICATION
• 2401 COFFEE 2.0
• 2402 FFF ISLAND REVISION
• 2404 BEVERAGE WALL DRAIN ACCESS PANELS
• 2405 SIDE DOOR
• 2406 GONDOLA END CAPS
• 2308 AUGUST EQUIPMENT CHANGES (A, B, C, E, F)
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PERMIT SET
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
G1.0
PROJECT NUMBER: 24212
ZONING #:XXXX, ENG. #:XXXX; BLDG. #:XXXX
FIRE PERMIT #, HEALTH PERMIT #
COVER SHEET AND
PROJECT
INFORMATION
STORE #XXXX
NWC YELM AV & KILLION RD
YELM, WA 98597
CIRCLE K
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
NUMBER NAME I
S
S
U
E
A
N
D
R
E
V
I
S
I
O
N
S
P
E
R
M
I
T
S
E
T
1
1
/
1
2
/
2
4
GENERAL
G1.0 COVER SHEET AND PROJECT INFORMATION ●
SITE PLAN
SD1.1 SITE PLAN ●
SD1.2 SITE DETAILS ●
SD1.3 SITE DETAILS ●
CIVIL
C0.0 COVER SHEET
C1.0 GENERAL NOTES
C2.0 DEMOLITION PLAN
C3.0 EROSION SEDIMENT CONTROL PLAN
C3.1 EROSION SEDIMENT CONTROL DETAILS
C4.0 SITE PLAN
C4.1 TRUCK ROUTING PLAN
C5.0 GRADING PLAN
C5.1 GRADING PLAN
C5.2 TYPICAL DRAINAGE CROSS SECTION
C6.0 UTILITY PLAN
C7.0 CONSTRUCTION DETAILS
C7.1 CONSTRUCTION DETAILS
C7.2 CONSTRUCTION DETAILS
C7.3 CONSTRUCTION DETAILS
C7.4 CONSTRUCTION DETAILS
C7.5 CONSTRUCTION DETAILS
LANDSCAPE
L5.0 LANDSCAPE PLAN
L5.1 LANDSCAPE NOTES
L5.2 LANDSCAPE DETAILS
IR4.0 IRRIGATION PLAN
IR4.1 IRRIGATION NOTES
IR4.2 IRRIGATION DETAILS
ARCHITECTURAL
A1.0 EGRESS/ ACCESSIBILITY FLOOR PLAN ●
A1.1 ACCESSIBLITY STANDARDS, NOTES/DETAILS ●
A1.2 FLOOR PLAN ●
A1.3 DIMENSIONED FLOOR PLAN, WALL TYPES, AND
ENLARGED RESTROOM ●
A1.4 EQUIPMENT PLAN ●
A1.5.1 EQUIPMENT LIST ●
A1.5.2 EQUIPMENT LIST ●
A1.5.3 EQUIPMENT LIST ●
A1.6 REFLECTED CEILING PLAN ●
A1.7 ROOF PLAN AND DETAILS ●
A1.8 FLOOR PENETRATION PLAN ●
A1.9 SECURITY SYSTEM FLOOR PLAN ●
A1.10 FLOOR FINISH PLAN ●
A1.11 WALL FINISH PLAN AND FINISH SCHEDULE ●
A2.1 EXTERIOR ELEVATIONS ●
A3.1 INTERIOR ELEVATIONS ●
A3.2 INTERIOR ELEVATIONS ●
A3.3 INTERIOR ELEVATIONS ●
A4.0 BUILDING SECTIONS ●
A5.1 WALL SECTIONS ●
A5.2 WALL SECTIONS ●
A6.0 ROOM KEY PLAN, DOOR/ WINDOW SCHEDULE &
TYPES, AND NOTES ●
A6.1 EXTERIOR ARCHITECTURAL DETAILS ●
A8.1 ARCHITECTURAL DETAILS (EXTERIOR)●
A8.2 ARCHITECTURAL DETAILS (EXTERIOR/INTERIOR)●
A8.3 EXTERIOR ARCHITECTURAL DETAILS ●
A9.1 INTERIOR ARCHITECTURAL DETAILS ●
A9.2 INTERIOR ARCHITECTURAL DETAILS ●
A9.3 PILASTER DETAILS ●
CA 1 FUEL CANOPY PLAN ●
CA 2 FUEL CANOPY ELEVATIONS ●
CA 3 FUEL CANOPY COLUMN DETAILS ●
STRUCTURAL
S0.1 GENERAL NOTES ●
S0.2 DIAGRAMS AND SCHEDULES ●
S0.3 TABLE OF SPECIAL INSPECTIONS ●
S1.0 FOUNDATION PLAN ●
S1.1 ROOF FRAMING PLAN ●
S2.0 FOUNDATION DETAILS ●
S2.1 FOUNDATION DETAILS ●
S2.2 FOUNDATION DETAILS ●
S3.0 ROOF FRAMING DETAILS ●
MECHANICAL
M1.1 MECHANICAL FLOOR PLAN ●
M1.1.1 MECHANICAL ROOF PLAN ●
M1.2 MECHANICAL DETAILS (1 OF 3)●
M1.2.1 MECHANICAL DETAILS (2 OF 3)●
M1.2.2 MECHANICAL DETAILS (3 OF 3)●
M1.2.3 MECHANICAL SCHEDULES ●
M1.2.4 MECHANCIAL NOTES ●
M1.2.5 ENERGY MANAGEMENT SYSTEM ●
M1.3 MECHANICAL SPECIFICATIONS ●
M1.4 CO2 LAYOUT PLAN AND NOTES ●
M1.5 CO2 CUT SHEETS ●
PLUMBING
P1.1 PLUMBING ROOF PLAN ●
P1.1.1 PLUMBING FLOOR PLAN WASTE AND VENT ●
P1.1.2 PLUMBING FLOOR PLAN DOMESTIC WATER ●
P1.2 PLUMBING RISER ●
P1.3 PLUMBING SCHEDULES AND DETAILS ●
P1.4 PLUMBING SPECIFICATIONS ●
ELECTRICAL
E0.0 ELECTRICAL COVERSHEET AND LEGEND ●
E0.1 ELECTRICAL SPECIFICATIONS ●
E1.0 ELECTRICAL SITE PLAN ●
E1.1 ELECTRICAL SITE DETAILS ●
E1.2 ELECTRICAL SITE PHOTOMETRIC PLAN ●
E1.3 EXTERIOR LIGHT FIXTURE CUT SHEETS ●
E2.0 ELECTRICAL FLOOR PLAN ●
E4.0 ROOF POWER PLAN ●
E5.0 LIGHTING PLAN ●
E5.1 IECC COMPLIANCE REPORT ●
E6.0 CALCULATIONS AND SCHEMATICS ●
E7.0 PANEL SCHEDULES ●
E7.1 PANEL SCHEDULES ●
FUEL CANOPY
CS1 CANOPY FOUNDATION PLAN ●
CS2 CANOPY ROOF PLAN & DETAILS ●
AB1 CANOPY FOUNFATION SECTIONS AND DETAILS ●
FUEL PLAN
TK001 COVER SHEET ●
TK002 GENERAL NOTES ●
TK006 EQUIPMENT LIST ●
TK007 EQUIPMENT LIST ●
TK101 TANK & PIPING DETAILS ●
TK102 SCHEMATIC WIRING, PIPING & DETAILS ●
TK201 STANDARD TANKS ●
TK301 TYPICAL UST PLAN AND SECTIONS ●
TK500 TANK SUMP DETAILS ●
TK501 TANK SUMP DETAILS ●
TK502 TANK TOP HARDWARE DETAILS ●
TK503 DISPENSER SUMP DETAILS ●
TK503.1 DISPENSER SUMP DETAILS ●
TK504 DUEL SYSTEM DETAILS ●
TK505 FUEL SYSTEM DETAILS ●
SHEET INDEX
OCCUPANT LOAD FIXTURE TYPE
FIXTURES
REQUIRED
FIXTURES
PROVIDED
SERVICE SINK
WATER CLOSETS
WATER CLOSETS
URINALS
LAVATORIES
LAVATORIES
PER WPC, WBC, AND TABLE 2902.1
FIXTURES PER
PERSON
1
MALE: 32
FEMALE: 32
1 500 1
0
1
1
1
1 0
0 0
1 750
1 500
1 750
TOTAL:63 1
2
2
2
4
2
BUILDING ENVELOPE REQ'TS
NUMBER NAME I
S
S
U
E
A
N
D
R
E
V
I
S
I
O
N
S
P
E
R
M
I
T
S
E
T
1
1
/
1
2
/
2
4
W0.0 COVER PAGE ●
W0.1 GENERAL NOTES ●
W0.2 GENERAL NOTES ●
W0.3 GENERAL NOTES ●
W1.0 WALL PLAN ●
W1.1 HOLD DOWN PLAN ●
W2.0 ELEVATIONS ●
W2.1 ELEVATIONS ●
W2.2 ELEVATIONS ●
W2.3 ELEVATIONS ●
W2.4 ELEVATIONS ●
W3.1 ROOF PLAN ●
W4.0 SECTIONS ●
W4.1 SECTIONS ●
W5.0 DETAILS ●
W5.1 DETAILS ●
W5.2 DETAILS ●
W5.3 DETAILS ●
W5.4 DETAILS ●
W5.5 DETAILS ●
SIP PANEL SHOP DRAWINGS
W
YELM AVENUE / SR 510
KILLION ROAD SE
(ACCESS ROAD)
ACCESSIBLE PATH OF TRAVEL
FIREFIGHTER WALKWAY ACCESS ROUTE
PROPERTY LINE
FIRE EXTINGUISHER, SEE FUEL TANK/GASF
A. SIGNS REQUIRE A SEPARATE PERMIT.
B. DUMPSTERS AND MECHANICAL EQUIPMENT WILL BE SCREENED FROM THE PUBLIC.
C. NOT USED.
D. PARKING WILL BE PAVED.
E. PARKING WILL BE WITHIN 600' OF BUILDING.
F. THERE SHALL BE NO OBSTRUCTION OF SITE SIGNAGE BY LANDSCAPE PLANT MATERIAL, AND SUCH MUST BE
RELOCATED/CORRECTED BEFORE THE FIELD INSPECTION WILL ACCEPT/PASS THE SIGN IN THE FIELD OR ISSUE A
CERTIFICATE OF OCCUPANCY FOR A PROJECT.
G. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR
GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT.
H. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL
EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT.
I. ALL SITE IMPROVEMENTS, INCLUDING LANDSCAPE AND SITE CLEANUP, MUST BE COMPLETED PRIOR TO CERTIFICATE
OF OCCUPANCY FOR ANY BUILDING WITHIN A PHASE.
J. THE FIRE DEPT. DOUBLE CHECK ASSEMBLY SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR.
K. ALL EXTERNAL LIGHTING SHALL BE LOCATED AND DESIGNED TO PREVENT RAYS FROM BEING DIRECTED OFF OF THE
PROPERTY UPON WHICH THE LIGHTING IS LOCATED.
PROJECT NAME:
PROJECT ADDRESS:
PROJECT DESCRIPTION:
CIRCLE K CONVENIENCE STORE & FUEL PUMPS
NWC YELM AVENUE & KILLION ROAD, YELM WA 98597
PROPOSAL FOR A NEW CONVENIENCE STORE WITH ASSOCIATED FUEL SALES CONSISTING OF A
5,200 S.F.CONVENIENCE STORE AND A 4,608 S.F.FUEL CANOPY WITH [7] FUEL PUMPS. THE
CONVENIENCE STORE WILL SELL BEER AND WINE FOR OFFSITE CONSUMPTION. THE FACILITY
WILL OPERATE 24 HOURS.
PARCEL/SITE AREA:2.35 AC / ±102,366 S.F.
EXISTING ZONING:C 1 COMMERCIAL
PARCEL NUMBER:21724130100
MAX. BUILD. HEIGHT:23' 0" PROVIDED (60' ALLOWED)
MAX. FUEL CANOPY HEIGHT:18' 6" PROVIDED (60' ALLOWED)
PARKING:
REQUIRED:5200 SF/250 = 21 PARKING STALLS
PROVIDED:
STANDARD PARKING:
ACCESSIBLE PARKING:
EVCS STALL:
TOTAL PARKING PROVIDED:
20 SP
1 SP
0 SP
21 SP
BICYCLE:2 BICYCLE RACK (4 SPACES) PROVIDED
S27
S3
S6
S20
S7
S17
S19
S6
S4
S5
S27
S2
S23
S21
S11
S15
S27
S11
S16
S10
S4
SLEEVE
DRIVE
S27
S2
S28
S10
S3
S11 S11
S22
S13
S27
S9 CIRCLE K
5,200 S.F.
F.F.F. = 353.50'
S1
S24 S11S14S26
S2
S24
SLEEVE
DRIVE
E STOP E STOP
FUEL CANOPY V 7
4,608 S.F.
S24 UNDER COUNTER
S2 S2
S18
S10
8K EO
20K REGULAR
12K
DIESEL
12K SUL
20
'
0
"
4
6
'
0
"
113' 0"
8K CK CHOICE
S32
S33
(SEE KEYNOTE A 30 ON SHEET A1.2)
S30
S3
S5S5
S6
S10
S18
S18
S18
S18
S22
S30
S30
S31
24
'
0
"
192' 0"
S T O P R A D I U S (T Y P.)
R =1 0 0' E M E R G E N C Y
S
T
O
P
R
A
D
I
U
S
(
T
Y
P
.
)
R
=
1
0
0
'
E
M
E
R
G
E
N
C
Y
S8
S8
S25
S25
S30
95' 5 5/8"
21
S29
FFF F F F F
S1. BUILDING AREA
S2. PAVING AT DRIVEWAY AND PARKING AREA, SEE CIVIL PLANS.
S3. LANDSCAPE AREA, SEE LANDSCAPE PLANS
S4. PROPOSED PYLON/MONUMENT SIGN, UNDER SEPARATE PERMIT. SEE ELECTRICAL PLANS FOR POWER REQUIREMENTS
S5. LANDSCAPE PLANTER AREA, SEE LANDSCAPE PLANS.
S6. CONCRETE WALK, SEE CIVIL PLANS AND SITE DETAILS SHEET SD1.2
S7. ELECTRICAL TRANSFORMER PROPOSED LOCATION. POWER COMPANY TO DETERMINE FINAL LOCATION.
S8. PROPOSED DIRECTIONAL SIGN, UNDER SEPARATE PERMIT. SEE ELECTRICAL PLANS FOR POWER REQUIREMENTS
S9. TRASH ENCLOSURE PER CITY STANDARD DETAILS, AND CIRCLE K APPROVAL. SEE SITE DETAIL 9/SD1.3
S10. CONC. CURB AND GUTTER, SEE CIVIL PLANS
S11. CONCRETE PAVING, SEE CIVIL PLANS
S12. PARKING LIGHT POLE FIXTURE, SEE STRUCT. & ELECT. PLANS.
S13. ACCESSIBLE RAMP, SEE CIVIL PLANS AND DETAIL 6/SD1.2
S14. ACCESSIBLE PARKING PER CITY REQUIREMENTS, SEE DETAIL 12/SD1.2
S15. VENT PIPES LOCATION, SEE FUEL PLAN.
S16. FUEL CANOPY AREA, SEE FUEL SHEETS FOR MORE INFORMATION
S17. BICYCLE RACK SEE DETAIL 14/SD1.2
S18. SCREEN WALL. SEE LANDSCAPE PLANS AND DETAILS.
S19. CO2 WITH STORAGE CABINET SEE DETAILS 3/A1.3
S20. BUILDING SERVICE DISCONNECT, SEE ELECTRICAL
S21. PROVIDE AND INSTALL FUEL STORAGE TANKS PER FUEL/GAS PLANS
S22. 4" BOLLARD, SPACED EVERY 6', SEE DETAIL 1/SD1.2
S23. AIR/WATER MACHINE,PROVIDED BY CIRCLE K VENDOR, SEE CIVIL AND ELECT. PLANS
S24. EMERGENCY SHUT OFF SWITCH, SEE FUEL PLAN
S25. PROPOSE BIORETENTION POND, SEE CIVIL PLANS AND DETAILS.
S26. OUTDOOR PAINTED STRIPES FOR NO PARKING AREA, SEE DETAIL 12/SD1.2
S27. PROPERTY LINE
S28. 6" DIA FUEL CANOPY BOLLARDS WITH GRAY COVERS
S29. GREASE INTERCEPTOR.
S30. BUILDING SETBACK
S31. EXISTING FIRE HYDRANT.
S32. GREASE TRAP, SEE CIVIL AND PLUMBING DWGS.
S33. EXTERIOR ROOF ACCESS LADDER
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
SD1.1
PROJECT NUMBER: 24212
SITE PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
SITE LEGEND
PROJECT DATA
GENERAL SITE NOTES
KEY NOTES
1" = 20' 0"
1SITE PLAN
4"
BOLLARD COVERED WITH "RED"
POST GAURD PLASTIC SLEEVE
4" SCH. 40 STEEL PIPE
CONCRETE FILLED BOLLARD
CAULK SEAL BOLLARD COVER
BASE, TYP.
FOAM WRAP, TYP.
FILL POST WITH CONCRETE
2500 PSI P.C. CONCRETE
MINIMUM, TYP.
1' 0"
4"
2'
8
"
3'
6
"
.
6'
6
"
.
3"
M
I
N
.
FRONT ENTRANCE
4" DIA.
BOLLARD
TYP. SEE
DET. 1/SD1.2
NOTE: EXPANSION JOINTS PER
INDUSTRY STANDARD
C STORE NTI
10
'
1
"
1'
6
"
10
'
4
"
6' 0" TYP.
BOLLARD COVERED WITH "RED
POST GAURD PLASTIC SLEEVE"
4" SCH. 40 STEEL PIPE
CONCRETE FILLED BOLLARD
CAULK SEAL BOLLARD COVER
BASE, TYP.
FOAM WRAP, TYP.
FILL POST WITH CONCRETE
2500 PSI P.C. CONCRETE
MINIMUM, TYP.
1' 0"
4"
2'
8
"
3'
6
"
.
MINIMUM
FINE $250
VAN
ACCESSIBLE
RESERVED
PARKING
4"
HANDICAP
PLATE OR PERMIT
ONLY
4"
4"
5'
0
"
.
RUST PROOF 2" ROUND
GALVANOZED POST INSIDE
THE STEEL BOLLARD AND
ENCASED IN CONCRETE
2'
6
"
6"
6
"
1
'
6
"
2"
2"
2"
2"
2"
2"
2" GREEN LETTERING
4" x 4" BLUE ACCESSIBLE SIGN
WHITE REFLECTIVE BACKGROUND
TYPICAL
1" GREEN LETTERING
11 GA. GALV. SHEET METAL
BACKING PLATE PAINTED
BOTH SIDES
2" GREEN LETTERING
3"
M
I
N
.
NOTES:
SIGNS SHALL BE MOUNTED TO POST
WITH GALVANIZED OR CADMIUM PLATE
5/16" DIAMETER STEEL BOLTS, NUTS
AND WASHERS. THE CONTRACTOR
SHALL SUPPLY AND INSTALL 5/16"
NYLON WASHERS BETWEEN BOLT
HEADS AND SIGN FACE TO PROTECT
FINISH.
1' 0"
6' 0" 5' 0" 6' 0"
6'
0
"
SLOPE
1:12 MAX.
SLOPE
1:12 MAX.
S
L
O
P
E
1:
1
2
M
A
X
.
CONCRETE WALK,
SEE PLAN
TOOLED
JOINTS AT
2" O.C.
EDGE OF WALK
TRUNCATED DOME
CONCRETE PAVERS
DETECTABLE SURFACE
'RED' OR 'YELLOW'
COLOR
NOTE: ALL A.D.A. REQUIREMENTS
TO BE INSTALLED PER APPROVED
ARCHITECT'S PLANS
TRUNCATED DOME CONCRETE PAVERS
DETECTABLE SURFACE 'RED' COLOR
TOOLED JOINTS AT 2" O.C.
LANDSCAPE AREA,
SEE SITE PLAN
LANDING
LANDSCAPE AREA,
SEE SITE PLAN
CONCRETE WALK, SEE
PLAN
5' 0"FLUSH
W/ASPHAL
T
6 0 " M I N .
2 ' 0 "
S L O P E 1 :1 2 M A X .
6 ' 0 "
M A X .
SD1.2
10
5' 0"
5'
0
"
5' 0"
4" WIDE YELLOW PAINT
STRIPING (TYP.)
4" WIDE YELLOW PAINT
STRIPING (TYP.)
THIS SIDE TOWARD DRIVE
AISLE
*
4" WIDE PAINT
STRIPING
(PAINTED WHITE)
*
22' 0"
11' 0" 5' 0" 6' 0"
BUILDING LINE
ACCESSIBLE PARKING SIGN WITH BOLLARDS, SEE DETAIL 5/SD1.2
0" CURB
DIAGONAL 4" PAINT STRIPING AT
24" O.C. (PAINTED WHITE)
8' ACCESS AISLE REQ'D
2.ACCESSIBLE SPACES MUST BE
PROMINENTLY OUTLINED IN
COLORS OR LATERALS
CONTRASTING FROM REGULAR
PARKING SPACES
3.INTERNATIONAL ACCESSIBLE
SYMBOL REQ'D
BLUE & YELLOW SYMBOL
PREFERRED
SYMBOL CAN BE DISPLAYED
WITHOUT BLUE BACKGROUND
4.ACCESSIBLE SIGN REQ'D MUST
NEVER BE OBSCURED
SD1.2
15
*2% MAX. SLOPE EACH WAY
EQ EQ
60
"
M
I
N
.
2'
4
"
1' 8"
2'
4
"
2' 2"
2" DIA. STEEL PIPE
BIKE RACK, PRIMED &
PAINTED
2 1/2" CONT. STEEL
PLATE, PRIMED &
PAINTED, WELD TO
STEEL PIPE.
4" CONC. PAVING ON 4"
A.B.C.
1/2" EXPANSION BOLT
@ 26" O.C.
2 1/2" CONT. STEEL
PLATE, PRIMED &
PAINTED, WELD TO
STEEL PIPE.
2" DIA. STEEL PIPE
BIKE RACK, PRIMED &
PAINTED
2' 2"
27
"
M
A
X
I
M
U
M
6"
6"
COMPACTED EARTH
#4 REINFORCING BAR
X 10" @ 4" O.C.
ASPHALT PAVING
C.I.P. CONC. CURB
3/4" R. TYP.
LANDSCAPE PLANTER AREA
.
1"4"1"
4" 8"
2"
6
"
8"
SLOPE 1/4"/FT
COMPACTED EARTH
#4 REINFORCING BAR
CONTINUOUS
PLANTABLE FILL
C.I.P. CONCRETE
WALK OVER 4" A.B.C.
3/4" R.
SLOPE 1/4"/FT
COMPACTED EARTH
#4 REINFORCING BAR
CONTINUOUS
BATTER 3:12
4" CONCRETE WALK
OVER 4" A.B.C.
3/4" R.
ASPHALT PAVING
6"
1'
0
"
4" 6"
SLOPE 1" PER FOOT
1'
0
"
6"
4" 6"
1"
COMPACTED EARTH
#4 REINFORCING BAR
CONTINUOUS
ASPHALT PAVING
4" CONC. WALK OVER 4" A.B.C.
3/4" R.
TRUNCATED DOME
CONCRETE PAVERS
DETECTABLE SURFACE
TOOLED JOINTS
@ 2" O.C.
1/2" CONTINUOUS
EXPANSION JOINT FILLER
CONCRETE SLAB, SEE STRUCT.
1/2" W x 1/2" D GROOVE W/
SEALANT AT SLAB
FACE OF WALL
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
SD1.2
PROJECT NUMBER: 24212
SITE DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1" = 1' 0"
1GUARD POST
1/8" = 1' 0"
4TYP.FRONT CONCRETE + BOLLARD
1" = 1' 0"
5HANDICAP ACCESSIBLE SIGN
3/16" = 1' 0"
6ACCESSIBLE RAMPS
1/2" = 1' 0"
7NOT USED
1/2" = 1' 0"
15ACCESSIBLE PARKING SYMBOL
1/8" = 1' 0"
12ACCESSIBLE PARKING STALL
3/4" = 1' 0"
14BIKE RACK DETAIL (TYPICAL OF 2)
1" = 1' 0"
2TEMPORARY EXTRUDED CURB
1" = 1' 0"
8EDGE OF WALK AT PLANTER
1" = 1' 0"
9SIDEWALK TURNDOWN
1" = 1' 0"
10WALK AT RAMP
3" = 1' 0"
13TYPICAL SLAB AT GRADE
6' 6" T.O. ENCLOSURE
FRAMING
PIPE BOLLARD REF PLAN
6" STL. DIA. GALVANIZED PIPE POST
FILLED WITH CONCRETE
NICHIHA FIBER CEMENT
PANELS
24 GA REVERSE R PANEL
SHEATHING
TREATED 2X4 HORIZONTAL
SUPPORTS
WOOD TO STEEL FENCE
LINE / END ADAPTER
3" NOM. O.D. GALVANIZED
STEEL POST
6 5/8" O.D. ROUND
SCHEDULE 40 PIPE WITH MIN.
CLEARANCE OF 3 1/2"
AROUND PIPE
GATE CLOSE POSITION
GA
T
E
O
P
E
N
P
O
S
I
T
I
O
N
ULTIMATE CLIP
20 GA. FLASHING, GC SUPPLIED
COLOR TO MATCH SHERWIN WILLIAMS
#SW 6090 JAVA FIRESTONE MANSARD
BROWN SR
1/2" APA RATED
PLYWOOD
TREATED 2X4
BLOCKING
TOP OF COLUMN AND
WOOD TO STEEL
FENCE LINE / END
ADAPTER BEYOND
3" NOM. O.D.
GALVANIZED STEEL
POST
NICHIHA TUFF
BLOCK COLOR TO
MATCH #SW 6115
TOTALLY TAN
3"
SEALANT
_______
SD1.3
7
_______
SD1.3
2
_______
SD1.3
8
_______
SD1.3
5
CONTROL JOINT, TYP.
SL
O
P
E
1/
4
"
/
F
T
SD1.3
1
6" 26' 0" 6"
12' 6" 12' 6"
EQ EQ EQ EQ EQ EQ
6"
1
3
'
0
"
1'
0
"
1
'
0
"
25' 0"
1' 0"10' 6"10' 6"1' 0"
11"4 1/2"10' 0"4"1' 9"4"10' 0"4 1/2"11"
3' 8" 3' 0" 3' 0" 3' 4" 3' 4" 3' 0" 3' 0" 3' 8"
5'
6
"
CL
R
3
1
/
2
"
4"
EQ
E
Q
4'
0
"
4"
3
1
/
2
"
(QTY. 7) 6"DIA
x4' 0" TALL STEEL
PIPE BOLLARD
GROUT, GROUT AND
SET 2' IN CONCRETE
FOOTING. MOUNTED
INSIDE
ENCLOSURE
3" NOM O.D.
GALVANIZED
STEEL POST WITH
WOOD TO STEEL
ADAPTER (TYP)
PROVIDE PVC
SLEEVES IN
CONCRETE TYP.
PEDESTRIAN
ACCESS GATE
6 5/8" O.D. ROUND
SCHEDULE 40 PIPE
WITH MIN.
CLEARANCE OF
3 1/2" AROUND
PIPE, TYP.
6" CONCRETE, DESIGN
STRENGTH 3,000 PSI WITH
NO. 4 REBARS AT 12" O.C.
BOTH WAYS.
RE
F
.
C
I
V
I
L
6"
6
'
0
"
20 GA. PRE FINISHED FLASHING
COLOR TO MATCH SHERWIN WILLIAMS
#SW 6090 JAVA
NICHIHA TUFF BLOCK
COLOR TO MATCH #SW 6115 TOTALLY TAN
11
1
/
8
"
6" DIA. GALVANIZED PIPE POST
COLOR TO MATCH #SW 6090 JAVA
NICHIHA TUFF BLOCK
COLOR TO MATCH #SW 6115
TOTALLY TAN
PROVIDE 3/4" PVC
SLEEVES IN CONCRETE. TYP
MUELLER URETHANE GATES
INTERNALLY COLOR TO MATCH
#SW 6090 JAVA
20 GA. PRE FINISHED FLASHING COLOR TO
MATCH SHERWIN WILLIAMS #SW 6090 JAVA
6" DIA. GALVANIZED
BOLLARD
6'
0
"
20 GA. PRE FINISHED FLASHING COLOR TO
MATCH SHERWIN WILLIAMS #SW 6090 JAVA
S.S. HANDLE
PROVIDE 3/4" PVC
SLEEVES IN CONCRETE. TYP
PROVIDE 3/4" PVC
SLEEVES IN CONCRETE. TYP
5/8" X 24" S.S. CANE
BOLT AT EACH GATE.
(ALTERNATE SIDES OF PANEL)
MUELLER URETHANE GATES
INTERNALLY COLOR TO MATCH #SW
6090 JAVA
6" DIA. GALVANIZED
BOLLARD
20 GA. PRE FINISHED FLASHING
COLOR TO MATCH SHERWIN
WILLIAMS #SW 6090 JAVA
6" DIA. GALVANIZED PIPE POST COLOR
TO MATCH #SW 6090 JAVA
NICHIHA TUFF BLOCK
COLOR TO MATCH #SW 6115 TOTALLY TAN
20 GA. PRE FINISHED FLASHING COLOR TO
MATCH SHERWIN WILLIAMS #SW 6090 JAVA
TOP OF STEEL PIPE
CONCRETE FILL TO BE
STRIKED OFF FLAT
6 5/8" O.D. ROUND SCHEDULE
40 PIPE WITH MIN. CLEARANCE
OF 3 1/2" AROUND PIPE, TYP.
LOWER ALUM. BRACKET
POST AND CONCRETE
FOOTING
UPPER ALUM. BRACKET
SEE STRU.
4'
1
1
1
/
2
"
1
'
4
"
S
E
E
S
T
R
U
.
MI
N
3"
20 GA. PRE FINISHED FLASHING
COLOR TO MATCH SHERWIN WILLIAMS
#SW 6090 JAVA
NICHIHA TUFF BLOCK COLOR TO
MATCH #SW 6115 TOTALLY TAN
3" NOM. O.D. GALVANIZED STEEL POST
TREATED 2X4 HORIZONTAL SUPPORTS
(TYP)
22 GA. REVERSE R PANEL SHEATHING
REF ARCH FOR SLAB
THICKNESS AND
REINFORCING
#4 T&B WITH MATCHING CORNER
BARS
T.O. ENCLOSURE FRAMING
6' 6"
17
5
/
8
"
1
7
5
/
8
"
1
7
5
/
8
"
1
7
5
/
8
"
6
"
SEE STRU.
SD1.3
4
SE
E
S
T
R
U
.
CL
R
3"
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
SD1.3
PROJECT NUMBER: 24212
SITE DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1 1/2" = 1' 0"
1ENCLOSURE GATE HINGE
3" = 1' 0"
4DETAIL COPING
1/4" = 1' 0"
9TRASH ENCLOSURE (PLAN)
1/2" = 1' 0"
7TRASH ENCLOSURE REAR ELEVATION
1/2" = 1' 0"
2TRASH ENCLOSURE SIDE ELEVATION
1/2" = 1' 0"
8TRASH ENCLOSURE FRONT ELEVATION 1/2" = 1' 0"
5TRASH ENCLOSURE SIDE ELEVATION
1/2" = 1' 0"
6GATE BOLLARD DETAIL
1/2" = 1' 0"
3TRASH ENCLOSURE WALL SECTION
A
A
B
B
1 1
2 2
TURNING RADIUS
ø 5' 0"
TURNING RADIUS
ø 5' 0"
(TO FACE OF SIP)
113' 0"
(TO FACE OF SIP)
46
'
0
"
(TO FACE OF SIP)
113' 0"
REMOTE DISTANCE
= 96' 10" TO EXIT #1
REMOTE DISTANCE
= 36' 0" TO EXIT #2
= 116' 0" TO EXIT #1
= 84' 1" TO EXIT #3
REMOTE
DISTANCE
= 51' 2"
REMOTE
DISTANCE
= 49' 9"
REMOTE DISTANCE
= 74' 0" TO EXIT #4
ADA
3' 0"
ADA
3' 0"
ADA
3' 0"
ADA
3' 0"
DIAGONAL DISTANCE
= 120' 8"
1/2 DIAGONAL DISTANCE
= 60' 4"
ADA
3' 0"
ADA
3' 0"
AD
A
3'
0
"
AD
A
3'
0
"
AD
A
3'
0
"
REMOTE DISTANCE
= 47' 8" TO EXIT #4
REMOTE DISTANCE
= 58' 2" TO EXIT #1
CO
M
M
O
N
P
A
T
H
O
F
T
R
A
V
E
L
D
I
S
T
A
N
C
E
=
4
2
'
0
"
COMMON PATH OF TRAVEL DISTANCE = 68' 8"
SIGN 1
SIGN 2
SIGN 3
SIGN 3
SIGN 3
SIGN 4 SIGN 5
TURNING RADIUS
ø 5' 0"
WALK IN
FREEZER
106
STORAGE
ROOM
103
COLD VAULT
105
HALLWAY
111
PREP AREA
110
CASHIER
108
SALES FLOOR
107
WALK IN
COOLER
104
BACK ROOM
109
AD
A
3'
0
"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
ADA
3' 0"
EXIT #2
SIGN 6
SIGN 2
BC
S
BC
S
EXIT #3 EXIT #1
SIGN 2
SIGN 3
SIGN 6
EXIT #4
TURNING RADIUS
ø 5' 0"
CO2
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
W H
ATM
4R
V
Z
C
3
0
T
2
4R
V
Z
C
3
0
4R
V
Z
C
3
0
4R
V
Z
C
3
0
T
2
CLEARANCE
3' 0"
TURNING RADIUS
ø 5' 0"
EXTERIOR
ROOF
ACCESS
LADDER
SIGN 1
AD
A
3'
0
"
AD
A
3'
0
"
TURNING RADIUS
ø 5' 0"
ADA
3' 0"
AD
A
3'
0
"
AD
A
3'
0
"
AD
A
3'
0
"
ADA
3' 0"
STRAIGHT LINE DISTANCE
= 82' 3"
AD
A
3'
0
"
ADA
3' 0"
AD
A
3'
0
"
ADA
3' 0"
ADA
3' 0"
MEN'S
RESTROOM
102
WOMEN'S
RESTROOM
101
OCCUPANCY: M
63 OCCUPANTS
AD
A
3'
0
"
= ROUTE FROM THE REMOTEST
ROOM OR SPACE TO NEAREST
EXIT
= STRAIGHT LINE DISTANCE
BETWEEN EXITS
= DIAGONAL DISTANCE OF THE
BUILDING OR AREA
1. MEANS OF EGRESS SHALL BE ILLUMINATED WITH AT LEAST
ONE FOOT CANDLE AT THE FLOOR LEVEL (WALKING
SURFACE), REFER TO ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION
2. CASHIER COUNTER HEIGHTS ARE 34", REFER TO INTERIOR
ELEVATIONS ON SHEET A3.1. PARALLEL APPROACH IS
PROVIDED AND COMPLY WITH ANSI 117.1 AND 2010 ADA
STANDARDS SECTION 904.4.1 EXCEPTION
= MOST REMOTE POINT WITHIN
THIS AREA
= ILLUMINATED EXIT SIGN
= EMERGENCY LIGHT
GENERAL NOTES
LEGEND
EXIT REQUIREMENTS
TRAVEL DISTANCE COMMON PATH OF TRAVEL
ALLOWABLE TRAVEL DISTANCE
200 FT PER WBC 2021 TABLE 1017.2 WITHOUT SPRINKLER
COMMON PATH PER WBC 2021 TABLE 1006.2.1 OF TRAVEL
DISTANCE WITHOUT SPRINKLER
75 FT
ACTUAL COMMON PATH OF TRAVEL DISTANCE
68' 8" FT.
MINIMUM NO. OF EXITS ARRANGEMENT MEANS OF EGRESS
REQUIRED 2
PROVIDED 4
REQUIRED DISTANCE
BETWEEN EXIT DOORS
WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED
FROM ANY PORTION OF THE EXIT ACCESS, THE EXIT DOORS OR
EXIT ACCESS DOORWAYS SHALL BE PLACED A DISTANCE APART
EQUAL TO NOT LESS THAN ONE HALF OF THE LENGTH OF THE
MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR
AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN
EXIT DOORS OR EXIT ACCESS DOORWAYS. INTERLOCKING OR
SCISSOR STAIRS SHALL BE COUNTED AS ONE EXIT STAIRWAY PER
WBC 2021 1007.1.1
EXCEPTION:
WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN
AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH
SECTION 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE OF
THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS
THAN ONE THIRD OF THE LENGTH OF THE MAXIMUM OVERALL
DIMENSION OF THE AREA SERVED.
ACTUAL STRAIGHT LINE
DISTANCE BETWEEN EXITS
EXIT #1 TO #2 = 82' 3"
ACTUAL STRAIGHT LINE
ACROSS PUBLIC AREA:
DIAGONAL AT PUBLIC
AREA = 120' 8"
1/2 DIAGONAL = 60' 4"
CONCLUSION =
= 82' 3" IS GREATER THAN
60' 4" (MEETS CODE FOR NON SPRINKLERED BUILDING)
(NUMBER AND ARRANGEMENT OF EXITS)
INTERNATIONAL SYMBOL OF ACCESSIBILITY
ACCESSIBILITY SIGNS
"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE
IS OCCUPIED"
LETTER MIN. 1" HIGH. SIGN MOUNTED ABOVE DOOR.
TACTILE EXIT SIGN SHALL COMPLY ADA STANDARD
SECTION 703.3 AND ANSI A117.1 2009
MEN RESTROOM
WOMEN RESTROOM
SIGN 1
SIGN 2
SIGN 3
SIGN 4
SIGN 5
NOTES:
INSPECTOR MAY REQUIRE ADDITIONAL EXIT SIGNS AT THE TIME OF
FINAL INSPECTION.
SIGNAGE COMPANY AND GC TO BOTH MAKE SURE ALL UTILITY LINES
HAVE BEEN LOCATED PRIOR TO DIGGING FOOTING.
GC RESPONSIBLE TO CALL AND HAVE UTILITIES LOCATED.
SIGNAGE COMPANY RESPONSIBLE TO CONFIRM THIS HAS BEEN
DONE.
EMPLOYEES ONLYSIGN 6
1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES.
2. THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX. GROSS SLOPE 2%.
3. WALKING SURFACE SLOPING GREATER THAN 2% SHALL BE SLIP RESISTANT.
4. PROVIDE A 60"x60" MIN. LANDING ON STRIKE SIDE OF DOOR W/ 44" MIN. WIDTH IN
DIRECTION OF TRAVEL.
5. WALKS SHALL EXTEND 18" TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE
THAT SWINGS TOWARD THE WALK.
6. THE SLOPE OF RAMPS SHALL NOT EXCEED 1' 0" IN 15' 0" U.N.O.
7. RAMPS SHALL HAVE A NON SLIP SURFACE.
8. RAMPS SHALL BE 48" WIDE MIN.
9. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3 FT.
WIDE BY NOT LESS THAN 6" 8" HIGH CAPABLE OF OPENING 90° AND MOUNTED SO
THAT THE CLEAR WIDTH OF THE EXIT WAY IS 32" MIN.
10.THRESHOLD TO BE A MAX. 1/2" ABOVE ADJACENT FINISH FLOOR.
11.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS.
12.THE BOTTOM OF ALL DOORS WITHIN 10" OF FINISHED FLOOR EXCEPT AUTOMATIC
AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE.
13.PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH PULL ACTIVATING BARS, OR
OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE
ABILITY TO GRASP THE OPENING HARDWARE. (34" TO 48" A.F.F.)
14.EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A
KEY OR SPECIAL KNOWLEDGE OR EFFORT, FLUSH OR SURFACE BOLTS SHALL BE
AUTOMATIC TYPE. LOCKABLE DOORS SHALL BE PROVIDED WITH A SIGN STATING "
THESE DOORS TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" IN MIN. 1"
HIGH LETTERS.
15.EXIT SIGNS WHERE NOTED OR REQUIRED SHALL BE WORDED "EXIT" IN AND LETTERS
HAVING THE PRINCIPAL STROKE OF NOT LESS THAN 3/4" WIDE AND 6" HIGH AND SHALL
CONFORM TO ALL APPLICABLE CODES.
ACCESSIBILITY NOTES
16.PROVIDE ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING AT ALL
EXIT CORRIDORS AS REQUIRED BY CODE. EMERGENCY LIGHTING SHALL
PROVIDE ILLUMINATION OF ONE FOOT CANDLE AT FLOOR LEVEL.
17.POST INTERNATIONAL SYMBOL OF ACCESSIBILITY ON OR ADJACENT TO
ALL ACCESSIBLE BUILDING ENTRANCES. LOCATION AS INDICATED BY
OWNER.
18.DESIGNATED SEATING SHALL BE ACCESSIBLE IN ACCORDANCE WITH
SECTION 902 OF ANSI 117.1 2009.
19.WORK SURFACES AT SYSTEMS AND FURNITURE FURNISHED AND
INSTALLED BY CIRCLE K STORES INC. SHALL BE IN COMPLIANCE WITH
SECTION 902 OF ANSI 117.1 2009.
20.SALES AND SERVICE COUNTERS: CUSTOMER SERVICE COUNTERS SHALL
BE IN COMPLIANCE WITH SECTION 904.3.1 AND 904.3.2 OF ANSI 117.1
2009. AND 2010 ADA STANDARD SECTION 904.4
21.CHECK OUT COUNTERS SHALL BE IN COMPLIANCE WITH SECTION 904.4
OF ANSI 117.1 2009.
22.FOOD SERVICE COUNTERS AND CONDIMENT STATIONS SHALL BE IN
COMPLIANCE WITH SECTION 904.4 OF ANSI 117.1 2009.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.0
PROJECT NUMBER: 24212
EGRESS/
ACCESSIBILITY FLOOR
PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
NOTE:
• PER ICC ANSI 117.1, 308. WHERE FORWARD REACH IS
UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48
INCHES MAXIMUM AND THE LOW FORWARD REACH SHALL BE
15 INCHES MINIMUM ABOVE THE FLOOR. TYPICAL.
3/16" = 1' 0"
1EGRESS / ACCESSIBILITY FLOOR PLAN
1' 3" (HOLD)
CENTERLINE
OF FIXTURE
F.
O
.
F
.
MIN.
.
CENTERLINE
OF FIXTURE
F.
O
.
F
.
1' 4" 1' 6" (HOLD)6" MAX.
MA
X
.
1'
0
"
5' 0"
4'
6
"
M
I
N
.
.
48" X 60" SPACE
IN FRONT OF
WATER CLOSET
8"
MAX.
.12"
MAX
.28"
MINIMUM
TO EDGE OF
WATER CLOSET
F.
O
.
F
.
CENTERLINE
OF FIXTURE
F.
O
.
F
.
5' 0"
.28"
MIN.
TO EDGE OF
WATER
CLOSET
6" MAX.CENTERLINE
OF FIXTURE
MIN.
.
.
.
48
"
M
I
N
.
CL
E
A
R
.24
"
.32"
MINIMUM
CLEARANCE
60"
MINIM U M
DIA M E T E R
C L E A R A N C E
1' 4" 1' 6" (HOLD)1' 3" (HOLD)
SINGLE ACCOMMODATION ROOMS NEW CONSTRUCTION
MINIMUM
1' 6"
NOTE: SIDE TRANSFER MAY VARY DEPENDING ON STATE
15
0
0
56
"
M
I
N
.
1525
60" MIN.
(A)
ADULT WALL HUNG
WATER CLOSET
16" 18"
14
2
0
59
"
M
I
N
.
1525
60" MIN.
16" 18"
15
0
6"
M
I
N
.
150
6" MIN.
30
5
12
"
M
I
N
.
PARTITION
(A)
ELEVATION
(B)
PLAN
(B)
ADULT FLOOR MOUNTED WATER CLOSET
AND CHILDREN'S WATER CLOSET
TOE CLEARANCE 150
6" MIN.
CLCL
WHEELCHAIR ACCESSIBLE COMPARTMENT
.6 0 "
M I N I M U M
D I A M E T E R
C L E A R A N C E
1'
6
"
MAX.
1' 0" 3' 6" MIN.
3' 3" 3' 6"
.
11" 17"
TO TOP OF
TOILET SEAT
7" 9"
1
1
/
2
"
14
"
M
I
N
.
19
"
M
A
X
.
2'
9
"
.
4' 6" MIN.
.
39
"
4
1
"
ROLL PAPER
HOLDER
WITHOUT STOPS
MIN.
1' 0"MIN.
3' 0"
MIN.
2' 0"
2'
9
"
.
.
1 1/2"
MAX
1 1/4" 1 1/2"
SOAP
TRASH
PRODUCT
DISPENSER
SEAT
COVER
DISPENSER
2'
0
"
M
I
N
.
3'
4
"
M
A
X
.
WATER CLOSET AND ACCESSORIES:
1. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17" AND A MAXIMUM OF 19"
MEASURED TO THE TOP OF A MAXIMUM 2" HIGH TOILET SEAT, EXCEPT THAT 3" SEATS SHALL BE
PERMITTED ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS THAN 15" HIGH.
2. THE CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE
TOILET AREAS. AUTOMATIC SPRING TO LIFTED POSITION SEATS ARE NOT ALLOWED.
3. THE FORCE REQUIRED TO ACTIVATE WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND
FAUCET AND OPERATING MECHANISM CONTROLS, SHALL BE NO GREATER THAN 5 LBS. ELECTRONIC
OR AUTOMATIC FLUSHING CONTROLS ARE ACCEPTABLE AND PREFERABLE.
4. WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, DISPENSERS, OR OTHER EQUIPMENT AND
CONTROLS ARE PROVIDED, PROVIDE AT LEAST ONE OF EACH TYPE SHALL BE ON AN ACCESSIBLE
ROUTE, WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM THE FINISHED FLOOR.
5. THE TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL WITHIN 7 9" OF THE FRONT EDGE
OF THE TOILET SEAT, MOUNTED BELOW THE GRAB BAR AT A MINIMUM HEIGHT OF 15", AND 48"
MAXIMUM AFF. DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER
FLOW SHALL NOT BE USED.
GRAB BARS:
1. THE REAR GRAB BARS SHALL BE 36" LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE
WATER CLOSET 12" MINIMUM ON ONE SIDE AND 24" MINIMUM ON THE OTHER SIDE. THE REAR GRAB
BAR SHALL BE SECURELY ATTACHED AND CENTERED 33" ABOVE AND PARALLEL TO THE FLOOR,
EXCEPT THAT WHERE A TANK TYPE TOILET IS USED, WHICH OBSTRUCTS PLACEMENT AT 33", THE BAR
MAY BE AS HIGH AS 36", WITH A 1 1/2" MINIMUM BETWEEN THE BAR AND TOP OF THE TANK.
2. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1 1/4" TO 2", OR THE
SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTED ADJACENT
TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL BE 1 1/2".
3. THE STRUCTURAL STRENGTH OF THE GRAB BARS, FASTENERS, AND MOUNTING DEVICES SHALL MEET
THE FOLLOWING SPECIFICATIONS:
A. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM
THE APPLICATION OF A 250 LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE
MATERIAL OF THE GRAB BAR OR SEAT.
B. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250 LB POINT LOAD
SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR
SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED,
THEN DIRECT AND TORSIONAL SHEAR STRESS SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS.
C. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A 250
LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR
MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE
LOAD.
D. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250 LB LOAD, SHALL
BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING
STRUCTURE.
E. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
4. THE GRAB BARS AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY
SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8".
1. ACCESSIBILITY STANDARDS MAY VARY SLIGHTLY FROM THOSE SHOWN HERE ACCORDING TO
THE REFERENCED STANDARDS OF THE APPLICABLE CODES, (ANSI A117.1 (I.B.C.)), THE YEAR
OF THE CODE ADOPTED AT THE TIME OF THE ISSUANCE OF THE CERTIFICATE OF
OCCUPANCY, THE LOCAL JURISDICTION REQUIREMENTS, THE CODE ITSELF AS STATED
(TITLE 24 OF THE C.B.C., B.O.C.A. OR THE I.B.C.), THE REQUIREMENTS OF AN ADOPTED STATE
LAW OR A PRECEDENT PREVIOUSLY SET FOR COMPLIANCE BY THE JUSTICE DEPARTMENT
(A.D.A.).
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INFORM THE ARCHITECT AND/OR THE CIVIL
ENGINEER OF ANY DISCREPANCIES, SUBTLE OR OTHERWISE, FROM WHAT IS SHOWN HERE
AND THE APPLICABLE CODE/LAW/ORDINANCE.
3. THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND
ARE INTENDED ONLY AS AID FOR BUILDING AND CONSTRUCTION.
GENERAL NOTES
16" 18"
CL
HAND
DRYER
DOOR NOTES:
1. WHEN INSTALLED, DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THE DOOR OPEN 90
DEGREES.
2. FOR HINGED DOORS, THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90
DEGREES FROM ITS CLOSED POSITION.
3. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING
WIDTH OF 32 INCHES WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.
4. THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL AREA SHALL HAVE A
LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60 INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF THE
DOOR SWING OF 48 INCHES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION.
WHERE THE PLANE OF THE DOORWAY IS OFFSET OR LOCATED IN AN ALCOVE A DISTANCE MORE THAN 8 INCHES MEASURED
FROM THE PLANE OF THE DOORWAY TO THE FACE OF THE WALL, THE DOOR SHALL BE PROVIDED WITH 60 INCHES
MANEUVERING CLEARANCE FOR FRONT APPROACH.
5. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24 INCHES PAST THE STRIKE
EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS. WHERE THE
PLANE OF THE DOORWAY IS OFFSET 8 OR MORE INCHES FROM ANY OBSTRUCTION WITHIN 18 INCHES MEASURED
LATERALLY ON THE LATCH SIDE, THE DOOR SHALL BE PROVIDED WITH MANEUVERING CLEARANCE FOR FRONT
APPROACH.
6. PROVIDE CLEAR SPACE OF 12 INCHES PAST STRIKE EDGE OF THE DOOR ON THE OPPOSITE SIDE TO WHICH THE DOOR
SWINGS IF THE DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER.
7. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF THE DOORWAY.
8. THE BOTTOM OF ALL DOORS WITHIN 10" ABOVE FINISH FLOOR EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH,
UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP
OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCH HIGH SMOOTH PANEL SHALL BE
INSTALLED ON THE PUSH SIDE OF THE DOOR WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST
WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.
THRESHOLD
2
1
1/
4
"
M
A
X
.
AT
1
:
2
S
LO
P
E
1/
2
"
M
A
X
.
FLOOR FINISH TO BE FLUSH OR
MEET SLOPE STANDARDS FOR
TRANSITIONS AS SHOWN ON
BOTH SIDES
FINISH FLOOR
EVEN
THRESHOLD
.
COMPRESSED CARPET
1/4" MAX. BELOW
THRESHOLD
DOOR HARDWARE NOTES:
1. DOOR HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE SHALL NOT
REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. MANUALLY OPERATED BOLTS OR SURFACE
BOLTS ARE NOT PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION.
2. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH TRAVEL SHALL BE OPERABLE WITH A
SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO
PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.
3. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44INCHES ABOVE THE FLOOR.
4. WHEN AN AUTOMATIC OR POWER ASSISTED DOOR OPERATOR IS UTILIZED TO OPERATE A PAIR OF DOORS, AT LEAST ONE OF THE
DOORS SHALL BE CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WITH THE DOOR POSITIONED AT AN ANGLE OF 90
DEGREES FROM ITS CLOSED POSITION. AUTOMATIC DOORS SHALL COMPLY WITH BHMA A156.10 OR BHMA A156.19.
EFFORT TO OPERATE DOOR
1. THE MAXIMUM FORCE REQUIRED TO PUSH OR PULL OPEN A DOOR SHALL COMPLY WITH THE FOLLOWING:
A. PUSH OR PULL FORCE FOR A HINGED DOOR SHALL BE MEASURED PERPENDICULAR TO THE DOOR FACE AT THE DOOR OPENING
HARDWARE OR 30 INCHES FROM THE HINGED SIDE, WHICHEVER IS FARTHER FROM THE HINGE.
B. PUSH OR PULL FORCE FOR A SLIDING DOOR OR FOLDING DOOR SHALL BE MEASURED PARALLEL TO THE DOOR AT THE DOOR PULL
OR LATCH.
C. DOORS AND GATE OPENING FORCE PER 2010 ADA SECTION 404.2.9 FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE
ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE
OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:
1) INTERIOR HINGED DOORS AND GATES ; 5 POUNDS (22.2N) MAXIMUM.
2) SLIDING OR FOLDING DOORS : 5 POUNDS (22.2N) MAXIMUM.
D. CLOSING SPEED DOOR AND GATE CLOSING SHALL COMPLY WITH SECTION 404.2.8 AS FOLLOWS:
1) DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME
REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM.
2) DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES,THE DOOR OR GATE
SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM.
.
3' 0" MIN.
.
42
"
M
I
N
.
60
"
M
I
N
.
54" MIN.
PULL SIDE
PUSH SIDE
*NOTE: 48" MINIMUM IF
DOOR HAS BOTH A
LATCH AND A CLOSER
4'
0
"
M
I
N
.
.
MIN.
1' 6"32" CLEAR
.12" MIN.
AS REQUIRED
SPACE IS NECESSARY TO ALLOW BACKING
AND TURNING SPACE FOR A WHEELCHAIR
TO CLEAR ANY DOOR IN ANY POSITION
MIN.
1' 0"
4'
0
"
M
I
N
.
5'
0
"
M
I
N
.
2' 0" MIN INTERIOR
1' 6" MIN. EXTERIOR
REQUIRED
CLEAR
SPACE
REQUIRED
CLEAR
SPACE
PROVIDE THIS
ADDITIONAL SPACE IF
DOOR HAS A LATCH
AND CLOSER
PULL SIDE
PUSH SIDE
MIN.
2' 0"
.
.
42
"
M
I
N
.
48
"
M
I
N
I
M
U
M
DO
O
R
P
R
O
V
I
D
E
D
WI
T
H
C
L
O
S
E
R
48
"
M
I
N
.
54
"
M
I
N
I
M
U
M
DO
O
R
P
R
O
V
I
D
E
D
WI
T
H
C
L
O
S
E
R
.
.
.
.
.
*36" MIN.
VERIFY EXIT
OCCUPANCY
LOAD
32" MIN.
.
60
"
M
I
N
.
24
"
M
A
X
.
LE
N
G
H
T
60" MIN.
PR
O
T
R
U
S
I
O
N
MINIMUM CLEAR WIDTH
FOR TWO WHEELCHAIRS
TERMINATION AT CORRIDORS/ HALL
NOTE:
36" MINIMUM IF OCCUPANT
LOAD IS LESS THAN 10.60" MIN.DOOR APPROACH AT HALLWAYS LATCH APPROACHDOOR APPROACH AT HALLWAYS HINGE APPROACHVESTIBULE DOORSSPACE AT DOORS FRONT APPROACH DOOR APPROACH AT HALLWAYS LATCH APPROACH
MI
N
48
"
MIN
42"
MIN
42"X<48"
NOTE: 48" MINIMUM DISTANCE
BETWEEN PROTRUSIONS
MIN.
11"ú
MAX.
6"
MI
N
.
9"
ú27
"
M
I
N
.
CLR.
8" MIN.
34
"
M
A
X
.
15
"
M
I
N
.
8" MIN. 19" MAX. OF THE 48"
CLR. FLOOR SPACE CAN
EXTEND UNDER LAVATORY
30"x48" MIN.
CLR. FLOOR
SPACE
KNEE CLEARANCE
FROM 9" TO 27" A.F.F.
TO BE 11" DEEP
REDUCING TO 8" DEEP
TOE CLEARANCE FROM
0" TO 9" A.F.F. TO BE 6"
DEEP BEYOND KNEE
CLEARANCELAVATORY SIDE ELEVATION
CL
29
"
M
I
N
.
LAVATORY NOTES:
1. PROVIDE A CLEAR SPACE 30"X48" MIN. IN FRONT OF THE LAVATORY. THE CLEAR SPACE MAY
EXTEND INTO KNEE AND TOE SPACE UNDER LAVATORY.
2. INSULATE OR CONFIGURE HOT WATER SUPPLY AND DRAIN PIPING UNDER LAVATORIES TO
PREVENT CONTACT.
3. NO SHARP OR ABRASIVE ELEMENTS ARE ALLOWED UNDER LAVATORIES.
4. FAUCETS CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO BE OPERABLE WITH
ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING OR TWISTING OF THE WRIST. THE
FORCE REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED 5 LBF. LEVER OPERATED,
PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF
EXCEPTABLE DESIGN.
5. SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10
SECONDS.
17" MIN.
TO
B
O
T
T
O
M
O
F
M
R
R
O
R
40
"
M
A
X
.
48
"
M
I
N
.
60
"
M
A
X
.
1. AT EVERY PRIMARY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION ALONG OR
LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL, THERE SHALL BE A SIGN DISPLAYING
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS SHALL INDICATE THE DIRECTION
TO ACCESSIBLE BUILDING ENTRANCES AND FACILITIES.
2. WHEN A BUILDING CONTAINS AN ENTRANCE OTHER THAN THE MAIN ENTRANCE WHICH
IS RAMPED OR LEVEL FOR USE BY DISABLED PERSONS, A SIGN SHOWING ITS LOCATION
IS REQUIRED TO BE POSTED AT OR NEAR THE MAIN ENTRANCE.
3. PROVIDE SIGNS WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY INDICATING LOCATION
OF EACH ACCESSIBLE ENTRY. PROVIDE ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED.
WINDOW
OPERATIOR .
15
"
M
I
N
.
48
"
M
A
X
.
SI
D
E
AP
P
R
O
A
C
H
15
"
M
I
N
.
48
"
M
A
X
.
FR
O
N
T
AP
P
R
O
A
C
H
CONVINIENCE
OUTLET
PULL
CHORD
SWITCH
CONVENIENCE OR
CONTROL DEVICE
CONTROLS, SWITCHES AND OUTLETSNOTES:
1. THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES AND OTHER
OPERABLE EQUIPMENT SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION MEETING THE
CLEARANCES AND REACH RANGE REQUIREMENTS.
2. CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA
TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING
AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED
FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE
BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM.
3. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND
COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES
MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NO
LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR
RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM.
4. EXISTING BUILDING MUST MEET SAME REQUIREMENTS AS NEW CONSTRUCTION UNLESS AN
UNREASONABLE HARDSHIP IS GRANTED BY THE ENFORCING AGENCY.
GRADE 2 BRAILLE
RAISED CHARACTERS
48
"
M
I
N
.
60
"
M
A
X
.
FINISHED FLOOR
CHARACTERS ON SIGNS SHALL BE RAISED 1/32" MIN. AND HAVE A WIDTH
TO HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO
HEIGHT RATIO OF BETWEEN 1:5 AND 1:10. THE MINIMUM CHARACTER
HEIGHT SHALL BE 5/8" MIN. AND 2" MAX. AND SANS SHERIF UPPER CASE.
GRADE 2 BRAILLE DOTS SHALL BE 1/10" ON CENTER IN EACH CELL WITH
2/10" SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN
OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE
SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE
BACKGROUND.
SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH
OUTSIDE THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH
SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE
NEAREST ADJACENT WALL, PREFERABLY TO THE RIGHT.
ADA ROOM
IDENTIFICATION
SIGN
STRIKE SIDE
OF DOOR
AREA FOR
HARDWARE
34
"
.
3".
48
"
.
48
"
M
I
N
.
60
"
M
A
X
.
UNISEX
WOMEN
MENGRADE 2
BRAILLE
NOTES:
1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND.
2. TACTILE CHARACTERS SHALL BE LOCATED 48" MIN. AFF, MEASURED FROM THE BASELINE OF
THE LOWEST TACTILE CHARACTER AND 60" MAX. AFF, MEASURED FROM THE BASELINE OF
THE HIGHEST TACTILE CHARACTER.
3. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR.
4. LETTERS & NUMBERS ON SIGNS SHALL BE RAISED 1/32" MIN., SHALL BE A MIN. OF 5/8" HIGH,
A MAX. OF 2" HIGH, & SHALL BE SANS SERIF UPPERCASE CHARACTERS ACCOMPANIED BY
CONTRACTED GRADE 2 BRAILLE.
OB
S
T
R
U
C
T
I
O
N
H
E
I
G
H
T
34
"
M
A
X
.
H
RE
A
C
H
H
E
I
G
H
T
48
"
M
A
X
.
REACH DEPTH
24" MAX.
D
REACH RANGE LIMITS
CORRESPONDING REACH HEIGHTS
FOR GIVEN DEPTHS:
WHEN D = 10" OR LESS, H = 48" MAX.
WHEN D = 24", H = 46" MAX.
20" MAX. FORWARD REACH
24" MAX. SIDE REACH,
36" MIN.
27
"
.
34
"
.
46
"
M
A
X
.
CL
E
A
R
F
O
R
TA
B
L
E
S
AN
D
CO
U
N
T
E
R
S
30
"
M
I
N
.
WI
D
E
@
PA
Y
P
O
I
N
T
S
ACCESS ON TWO SIDES
36" MIN.
ACCESS ON ONE SIDE
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.1
PROJECT NUMBER: 24212
ACCESSIBLITY
STANDARDS,
NOTES/DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597N.T.S.
D7COMPARTMENTS/TOE CLEARANCE
N.T.S.
D1WATER CLOSET AND TOILET ACCESSORIES NOTES AND INFORMATION
N.T.S.
A5DOORS
N.T.S.
K3DOOR OPENINGS & CORRIDORS/HALLS
N.T.S.
G7LAVATORIES
N.T.S.
G5ENTRY AND DIRECTIONAL SIGNS
N.T.S.
G13CONTROLS AND OPERATING MECHANISMS
N.T.S.
D5EXIT TACTILE SIGN
N.T.S.
A3RESTROOM SIGNS
N.T.S.
A1REACH RANGES
N.T.S.
K1AISLES
KB
A
A
B
B
1 1
2 2
WALK IN
FREEZER
106
STORAGE
ROOM
103 COLD VAULT
105
HALLWAY
111
MEN'S
RESTROOM
102
SALES FLOOR
107
PREP AREA
110
CASHIER
108
BACK ROOM
109
WALK IN
COOLER
104
(TO FACE OF SIP)
113' 0"
103
102A 101A
101B
3
A8.2
______
A8.2
4
1
A8.2
______
A1.3
2
A9.2
3
A9.2
1
A6.1
4
(TO FACE OF SIP)
113' 0"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
1
A8.2
______
A8.2
2
A 4
A 9
A 10A 11
A 12A 12
A 12A 12
A 15A 16 A 17
A 17
A 18A 19
A 15
A 15
A 27
A 27
A 27
A 32
A 33
A 38
A 38
A 38
A 39
A 44
A 12A 12
A 27A 27
A 38
A 1A 1
A 41A 41
A 27
101C
101D
102B
A 41A 41A 41A 41
A 1A 1
OCCUPANCY: M
63 OCCUPANTS
A 47
A 4
A8.2
7
A 45
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EXTERIOR
ROOF ACCESS
LADDER
A 2A 2 A 7
108A
A 7 A 7A 25
B 108B C
A 7 A 25
A B
A 25
A 36
BC
S
A 41A 41
A 1A 1A 15
CO2
A 35
A 36
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
A 22
6
A8.1
______A8.2
6
6
A8.1
______
A6.1
2
6
A8.1
______
4
A9.2
______
3
A8.2
______
A8.2
2
A8.2
7
1
A4.0
______1
A4.0
______
3
A4.0
______
3
A4.0
______
A 37
A 9
_______
A2.1
2
_______
A2.1
1
_______
A2.1
3
_______
A2.1
4
A 31
A 9A 37
A 9
A 37
A 21
A 15
A 32
A 37
A 9
107
A 11
BELOW
4R
V
Z
C
3
0
T
2
4R
V
Z
C
3
0
4R
V
Z
C
3
0
4R
V
Z
C
3
0
T
2
BC
S
ATM
WINE RACK
A8.3
6
A 41A 41
A 41
TYP.
A 31
A 13
A 44A 44
A 37
A 3
A 37
A 37
A 25
A 14
A 9
TYP.
A 31
COMMISSARY RACKS
A 41
A 32A 32
A 32
A 32
A 4
A 2A 2
A 32
A 32
A 50
A 42
A 38
A 42
A 48
A 41
A 17
A 6 A 4
A 4
A 43
A 43
A 6 A 15 A 6
A 15
A 6 A 4
A 27
A 10
A 6 A 4
A 4A 5
A 30
A 29
A 15
A 4
111
A 26
A 49
SHUT
OFF
SHUT
OFFA 30
A 30
6 5/8" SIP WALL PANEL. SEE SIP VENDOR SHEETS
6" 20ga. METAL STUD AT 16" O.C. WITH BATT INSULATION.
SEE SHEET A1.3 FOR WALL TYPES
3 5/8" 20ga. METAL STUD AT 16" O.C. (WITH BATT INSULATION IF APPLICABLE)
SEE SHEET A1.3 FOR WALL TYPES
3 5/8" 20ga. METAL STUD AT 16" O.C. TO DECK WITH BATT INSULATION.
SEE SHEET A1.3 FOR WALL TYPES
3 5/8" METAL STUD FURRED WALL (WHERE OCCURS) AT 16" O.C.
FIBER CEMENT WAINSCOT/ PILASTER
PRE MANUFACTURED FREEZER/COOLER WALL
SIP PANEL WALL W/ F.R.P. PANELING, SEE KEYNOTES & SHT. A3.2
3/4" FRT. PLYWOOD W/ F.R.P. PANELING,
SEE KEYNOTES 37 & SHT. A3.2
WINDOW TYPE: SEE WINDOWS SCHEDULE SHEET A6.0
DOOR TYPE: SEE DOOR SCHEDULE SHEET A6.0
X
X
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.2
PROJECT NUMBER: 24212
FLOOR PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3/16" = 1' 0"
1FLOOR PLAN
NUMBER DESCRIPTION
A 1
CONCRETE SLAB WITH MINIMUM 15ML 'CLASS A' VAPOR
BARRIER LAPPED A MINIMUM OF 6" & TAPED PER
MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL
A 2 CONCRETE WALK, BROOM FINISH, SEE CIVIL
A 3 EXTERIOR ROOF ACCESS LADDER, SEE DETAIL 7/A8.3
A 4 CUSTOM CASEWORK SUPPLIED BY CIRCLE K, INSTALLED BY
OTHERS
A 5 SALES COUNTER, SEE SHEET A1.4 FOR EQUIPMENT.
A 6 SOLID SURFACE COUNTER TOP SUPPLIED BY CIRCLE K,
INSTALLED BY OTHERS
A 7 ALUMINUM STOREFRONT SYSTEM, SEE SHEET A6.0 FOR DOOR &
WINDOW SCHEDULES
A 9 PEBBLE SURFACE MARLITE F.R.P. PANELING TO 6" ABOVE
FINISH CEILING, P 100 WHITE, OR EQUAL. SEE SHT. A3.2.
A 10 PROVIDE INTEGRAL SPLASH GUARD AT HAND SINK
A 11 5 LB. 2A 10BC FIRE EXTINGUISHER, SURFACE MOUNTED AT 48"
A.F.F., PROVIDE BLOCKING AS REQUIRED
A 12
COOLER/FREEZER PROVIDED AND INSTALLED BY CIRCLE K.
GENERAL CONTRACTOR RESPONSIBLE FOR ELECTRICAL AND
PLUMBING CONNECTIONS.
A 13 COOLER REACH IN DOOR, SUPPLIED/INSTALLED BY
COOLER/FREEZER MANUFACTURER
A 14 COLD VAULT DOOR & WINDOW, SUPPLIED/INSTALLED BY
COOLER/FREEZER BY MANUFACTURER
A 15 FLOOR SINK ACCESSIBLE FOR CLEANING, SEE PLUMBING
DRAWING
A 16
MOP SINK WITH FAUCET, SEE PLUMBING DRAWING FOR
SPECIFIC INFORMATION (G.C. TO ADD 24" LONG GARDEN HOSE
FOR MOP SINK FAUCET).
A 17 HAND SINK, SEE PLUMBING DRAWINGS FOR SPECIFIC
INFORMATION
A 18 3 COMPARTMENT SINK, SEE PLUMBING DRAWINGS FOR
SPECIFIC INFORMATION
A 19 50 GALLON WATER HEATER ON SHELF ABOVE, SEE PLUMBING
AND ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION
A 21 LOCATION OF ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS
FOR SPECIFIC INFORMATION
A 22
LOCATION OF SERVICE DISCONNECT. IF REQUIRED, PROVIDE 4"
CONCRETE HOUSEKEEPING PAD ABOVE SIDEWALK UNDER
CABINET COORDINATE SIZE AND LOCATION PAD AND CABINET
WITH ELECTRICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS
FOR SPECIFIC INFORMATION.
A 25 LINE OF CANOPY / SOFFIT ABOVE, SEE REFLECTED CEILING
PLAN SHEET A1.6 AND EXT. ELEVATIONS SHEET A2.1
A 26 KNOX BOX LOCATION, SEE RECESS DETAILS 1/A8.1 (IF REQUIRED
BY FIRE DEPARTMENT)
A 27 PROVIDE SIGN ABOVE HAND SINK "EMPLOYEE MUST WASH
HANDS BEFORE RETURNING TO WORK"
A 29 34" HIGH ACCESSIBLE COUNTERTOP
A 30 FUEL EMERGENCY SHUT OFF SWITCH WITH COVER, PROPOSED
LOCATION WHEN REQUIRED, SEE FUEL PLAN.
A 31 SIPS PANEL WALL, SEE DETAIL 8/A8.1, SIP SHEETS,
STRUCTURAL, BUILDING SECTIONS AND EXTERIOR ELEVS.
A 32 2" STAINLESS STEEL CORNER GUARDS TO 54" A.F.F.
A 33 4" CONC. CURB AT ELECTRICAL PANELS
A 35 CO2 TANK AT EXTERIOR WITH STORAGE TANK CABINET. SEE DET.
2/A9.1 FOR REQUIRED SIGNS.
A 36 HOSE BIBB, SEE PLUMBING DRAWINGS
A 37 FRP PANELING, SEE LEGEND AND SHT. A3.2.
A 38 STORAGE LOFT, SEE INTERIOR ELEVATIONS FOR HEIGHT, SEE
DETAIL 4/A9.2 OR ALTERNATE LOFT DETAIL 12/A9.2
A 39 FURRED OUT WALL TO CLOSE GAP BETWEEN WALL AND WALK
IN COOLER FROM BOTTOM TO CEILING, SEE DETAIL 6/A9.2
A 41 FRP TILE FINISH, SEE FINISH SCHEDULE AND SHEETS A1.11, A3.1
& 3.3
A 42 LINE OF SOFFIT ABOVE
A 43 PROVIDE HUB DRAIN AND ROUTE DRAIN TO NEAREST FLOOR
SINK, SEE PLUMBING DRAWINGS
A 44 BREAK METAL TO CLOSE GAP BETWEEN WALL AND WALK IN
COOLER FROM BOTTOM TO CEILING, SEE DETAIL 3/A9.2
A 45 G.C. TO PROVIDE METAL KEY STORAGE BOX FROM GRAINGER
MFR.
A 47 6"X6" PIPE CHASE.
A 48 WALK IN FREEZER RAMP, SUPPLIED/INSTALLED BY
COOLER/FREEZER MANUFACTURER
A 49 HI LO DRINKING FOUNTAIN.
A 50 FILLER PANEL VENDOR PROVIDED, GC TO INSTALL.
KEY NOTES
LEGEND
A
A
B
B
1 1
2 2
WALK IN
FREEZER
106
STORAGE
ROOM
103
COLD VAULT
105
WALK IN
COOLER
104 BACK ROOM
109
SALES FLOOR
107
HALLWAY
111
A
A
EE
B E
B
6' 11 1/2"
3' 0"
22' 0 1/4"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
F F
A9.3
4
A9.3
3
(TO FACE OF SIP)
113' 0"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
CO2
PREP AREA
110
CASHIER
108
F
6'
0
"
1'
8
"
USE 6"
MTL. STUD
7' 1 1/2" 6' 0"7' 7 1/2"
45' 7 1/2" 11' 5 1/2" 8' 5"
7' 8 1/2"
D
4' 1" 10' 9 1/2"
(4) EQ. PANELS WINDOW
16' 10" 4' 0" 3' 2"
(3) EQ. PANELS WINDOW
12' 8" 4' 2"
(3) EQ. PANELS WINDOW
12' 8" 3' 2" 4' 0" 4' 4"
(2) EQ. PANEL WINDOWS
8' 4" 6' 1 1/2" 4' 1" 7' 3 1/2"
(TO FACE OF SIP)
113' 0"
10
'
9
1
/
2
"
20' 9"
16' 0 3/8" 16' 7 7/8" 5' 9 5/8"
FFF
F F
BC
S
BC
S
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
21' 4" 80' 2 1/2" 11' 5 1/2"
A1.3
2
F.O.P.
F.O.P.
16' 7" 22' 10" 44' 8 3/8" 28' 10 3/4"
EXTERIOR
ROOF ACCESS
LADDER
F.O.P.
F.O.P.
1'
6
"
A
A
USE 3 5/8"
MTL. STUD
7' 8" 31' 8" 5' 9" 22' 10" 5' 9" 31' 8" 7' 8"
C
3
3
/
4
"
3
3
/
4
"
A
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
4' 6"2' 5 1/2"
WH
4R
V
Z
C
3
0
T
2
4
R
V
Z
C
3
0
4R
V
Z
C
3
0
4R
V
Z
C
3
0
T
2
1
A4.0
______1
A4.0
______
3
A4.0
______
3
A4.0
______
4
A4.0
______
4
A4.0
______
USE 6"
METAL
STUD
4'
1
0
1
/
2
"
2'
7
1
/
2
"
6'
8
1
/
2
"
A
FA
C
A
D
E
A
B
O
V
E
3'
1
"
F.O.P.
12
'
8
"
5
'
4
"
2
8
'
0
"
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.
O
.
P
.
F.O.P.
F.O.P.
F.O.P.
F.O.P.
7'
8
"
D AIR GAP
1" MIN.
8'
5
"
7' 3 1/2"
AIR GAP
1" MIN.
10' 6 1/4"
5' 4"
7'
8
"
5
'
0
"
7'
8
"
26
'
1
1
3
/
4
"
26' 7" 24' 7 1/2"
2
6
°
1'
6
"
5
'
8
1
/
2
"
2
'
9
1
/
4
"
2'
0
"
2'
1
1
"
11' 4 1/4"
7'
3
1
/
2
"
4' 0"
6'
4
5
/
8
"
3
'
4
1
/
2
"
3
'
5
"
3
'
4
1
/
2
"
7
'
2
1
/
2
"
4' 4 1/4" 2' 11 1/2" 4' 6" 2' 11 1/2" 4' 6" 2' 11 1/2" 5' 0" 2' 11 1/2" 10' 6 3/8"
5 1/4"
MEN'S
RESTROOM
102
WOMEN'S
RESTROOM
101
VE
E
D
E
R
RO
O
T
17
'
2
1
/
4
"
1'
3
"
6'
9
"
9
'
2
"
30
'
7
3
/
4
"
4'
7
"
4'
9
1
/
4
"
7' 9 1/2"
5' 0"11' 0 1/2"
14' 0 1/2"
26' 10" 10' 5 1/2"
3' 0" 4' 10" 2' 6" 4' 0" 6' 0" 6' 6"
17
'
4
7
/
8
"
5'
6
"
2
'
0
"
2
'
0
"
2
'
0
"
4
'
1
0
7
/
8
"
35
'
6
3
/
4
"
5' 0"
4'
7
"
5'
0
"
5' 0"4' 0"
5'
5
"
4'
1
"
4' 6"
USE 6"
METAL
STUD
A3.33D
3C
3B
3A
A3.3
4C
4D
4A
4B
B 23
B 16
B 10
B 1
B 2
B 11
B 13
B 11B 11
B 1
B 11
B 7
B 11
B 10
B 10
B 10
B 16
B 3
B 8
B 23
B 9
B 10
B 10
B 12
B 23
60" MIN.
5' 0 1/4"CLEAR
12" MIN.
1'
6
"
6'
3
1
/
2
"
3
'
2
"
3
'
6
"
3
'
1
1
/
2
"
B 15 B 14
B 23
B 16
B 16
B 3
B 8
B 10
RR SIGN
SEE 1/A9.1
2' 10 1/2"
12' 4 1/2" 4' 0"
B 10 B 10
B 10
RR SIGN
SEE 1/A9.1 B 10
B 11
B 10
B 2
B 10B 10
B 10B 10
B 6
B 10
B 12
B 10
B 10B 10
60" MIN.
5' 0 1/4"
B 15
6'
3
1
/
2
"
3
'
6
"
3
'
2
"
3
'
2
"
4'
6
1
/
2
"
2
2
'
5
"
60" MIN.
5' 0 1/4"
B 14
6' 0"
CL
CL
CL
CL
CL
CL
CL
B 24
B 10B 10
BC
S
BC
S
B 15 B 14
WC
WC
WC
A3.3
6
UR
B 2
B 19
B 6
B 10 B 10
B 5
B 18
UR
MEN'S
RESTROOM
102
WC
B 10 B 10 B 10 B 10
B 10B 10B 10
B 25
CL
E
A
R
T
YP
.
5'
0
3
/
8
"
M
I
N
.
CL
E
A
R
T
YP
.
5'
0
3
/
8
"
M
I
N
.
B 22
B 1B 1
B 26
B 17
10' 5 1/2" 9' 11 1/2"
7' 1 1/2"7' 3 1/8"
20' 4 1/2"
4' 0"
B 10
B 14
B 19CLEAR
5' 0"B 5
B 5
1'
4
1
/
2
"
B 22
B 8 B 8
B 19
B 19
B 14
B 6
B 15
CLEAR
5' 0 1/2"
2'
9
"
2'
9
"
3'
1
"
1'
6
1
/
2
"
3'
1
"
1'
7
"
2'
9
"
1'
4
1
/
2
"
2'
9
"
B 5
B 5
B 13
B 6
B 25
B 2
B 19
WOMEN'S
RESTROOM
101
B 4
B 2
B 7
B 2
B 10B 10B 10
B 10B 10B 10
B 10B 10B 10
B 18
B 5B 19
B 14
B 12
B 12
B 12
B 12
B 12
B 12
5'
9
1
/
2
"
A9.1
7
CL
5' 11 1/8" 1' 3" 2' 3" 1' 0"
6' 7 1/2" 3' 3"
1' 0" 3' 6"
3' 3"
3 ' 6 "
A3.3
8
1. ALL INTERIOR NON METAL SURFACES TO BE PAINTED SHALL BE PRIMED WITH SHERWIN
WILLIAMS ProMar® 200 Zero VOC Interior Latex Primer
2. ALL INTERIOR METAL SURFACES TO BE PAINTED SHALL BE PRIMED WITH SHERWIN
WILLIAMS Pro Industrial™ Pro Cryl® Universal Acrylic Primer
3. ALL INTERIOR SURFACES TO BE PAINTED SHALL BE PAINTED WITH SHERWIN WILLIAMS
Duration Home® Interior Acrylic Latex Paint
** SEE SHEET A2.1 "EXTERIOR ELEVATIONS" FOR PAINT TYPE SELECTION OF EXTERIOR WALLS **
DRYWALL INTERIOR/EXTERIOR
DRYWALL MUST BE CLEAN AND DRY. ALL NAIL HEADS MUST BE SET AND SPACKLED. JOINTS
MUST BE TAPED AND COVERED WITH A JOINT COMPOUND. SPACKLED NAIL HEADS AND TAPE
JOINTS MUST BE SANDED SMOOTH AND ALL DUST REMOVED PRIOR TO PAINTING.
EXTERIOR SURFACES MUST BE SPACKLED WITH EXTERIOR GRADE COMPOUNDS.
STEEL SOLVENT CLEANING
SOLVENT CLEANING IS A METHOD FOR REMOVING ALL VISIBLE OIL, GREASE, SOIL, DRAWING AND
CUTTING COMPOUNDS, AND OTHER SOLUBLE CONTAMINANTS. SOLVENT CLEANING DOES NOT
REMOVE RUST OR MILL SCALE.
CHANGE RAGS AND CLEANING SOLUTION FREQUENTLY SO THAT DEPOSITS OF OIL AND GREASE
ARE NOT SPREAD OVER ADDITIONAL AREAS IN THE CLEANING PROCESS. BE SURE TO ALLOW
ADEQUATE VENTILATION.
WOOD INTERIOR
ALL FINISHING LUMBER AND FLOORING MUST BE STORED IN DRY, WARM ROOMS TO PREVENT
ABSORPTION OF MOISTURE, SHRINKAGE, AND ROUGHENING OF THE WOOD.
ALL SURFACES MUST BE SANDED SMOOTH, WITH THE GRAIN, NEVER ACROSS IT.
SURFACE BLEMISHES MUST BE CORRECTED AND THE AREA CLEANED OF DUST BEFORE
COATING.
RESTROOM SIGN NOTE:
SIGNS DENOTING THE RESTROOMS SHALL INCLUDE LETTERS AND NUMERALS THAT ARE
RAISED 1/32", UPPER CASE, SANS SERIF OR SIMPLE SANS SERIF AND SHALL BE ACCOMPANIED
WITH GRADE 2 BRAILLE.
MOUNTING HEIGHTS FOR THE SIGNS DENOTING THE RESTROOMS SHALL BE LOCATED 48
INCHES MINIMUM ABOVE THE FINISH FLOOR, MEASURED FROM THE BASELINE OF THE LOWEST
TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED FROM
THE BASELINE OF THE HIGHEST TACTILE CHARACTER. MOUNTING LOCATION FOR THE SIGN
SHALL BE SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF THE SIGN WITHOUT
ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR.
A. WALL TYPE 'A', SEE 3/A9.1
B. WALL TYPE 'B', SEE 6/A9.1
C. WALL TYPE 'C', SEE 9/A9.1
D. WALL TYPE 'D', SEE 12/A9.1
E. WALL TYPE 'E', SEE 11/A9.1
F. WALL TYPE 'F', SEE 10/A9.1 & 7/A9.1
NOTES:
A. SEE ROOM FINISH SCHEDULE ON SHEET A1.11.
B. SEE EQUIPMENT SCHEDULE ON SHEETS A1.4, A1.5.1, A1.5.2 AND A1.5.3
C. SEE DETAIL 5/A3.3 FOR RESTROOM TYPICAL WALL TILE PATTERN.
D. SEE SHEET A3.3 FOR RESTROOM ELEVATIONS AND DETAILS.
1. INTERIOR DIMENSIONS SHOWN ARE TO INTERIOR WALL FINISH, UNLESS OTHERWISE NOTED.
2. EXTERIOR DIMENSIONS SHOWN ARE TO FACE OF SIP WALL PANELS, UNLESS OTHERWISE
NOTED.
3. SEE SHEETS A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT.
4. COORDINATE ALL DIMENSIONS IN AREAS OF WALK IN COOLERS WITH EQUIPMENT INSTALLERS.
5. INSTALL FULL THICKNESS ACOUSTICAL BATT INSULATION CONTINUOUS TO ROOF DECK IN ALL
WALLS SEPARATING RESTROOMS FROM ADJACENT CONVENIENCE STORE AREAS. INSULATION TO
BE NON COMBUSTIBLE, BEARING THE U.L. CLASSIFICATION MARKING.
6. BRACE STUDS ABOVE CEILING AS REQUIRED TO PROVIDE RIGID WALLS THROUGHOUT, SEE
STRUCTURAL DRAWINGS.
7. ALL CABINETS IN FOOD OFFERING AREA, INCLUDING COFFEE BAR AND SALES COUNTER, TO
HAVE SOLID TOP WITH METAL SIDES PAINTED AND KICK PLATE BASE PAINTED "BLACK".
8. USE FDA APPROVED FOOD GRADE CLEAR CAULKING BETWEEN COUNTERTOPS AND WALLS AND
WHERE REQUIRED PER LOCAL AND COUNTY HEALTH DEPARTMENT REQUIREMENTS.
9. GENERAL CONTRACTOR SHALL COORDINATE WITH THE EQUIPMENT AND DRYWALL INSTALLERS
TO ENSURE THAT ALL ELECTRICAL WIRING, WATER LINES AND REFRIGERATION LINES HAVE BEEN
INSTALLED PROPERLY ON ALL EQUIPMENT PRIOR TO THE HANGING OF ANY DRYWALL, SEE THE
CIRCLE K PROJECT MANAGER FOR ANY EQUIPMENT LOCATION CLARIFICATIONS.
10.PROVIDE 5/8" MOISTURE RESISTANT GYPSUM WALLBOARD THROUGHOUT, BEHIND
COOLER/FREEZER, RESTROOMS, BEHIND 3 COMP SINK, BEHIND FRONT COUNTER UNDER GLASS,
MOP SINK AND HOT WATER HEATER.
11.SEE SHEET A1.11 FOR ROOM FINISH SCHEDULE.
12.SEE SHEETS A3.1, A3.2, AND A3.3 FOR INTERIOR ELEVATIONS.
NOTE:
SERVICE HOSE SHALL BE FLEXIBLE POLYOLEFIN HOSE FOR MEDIUM PRESSURE SERVICE
(STYLE 540P), COMPLIANT WITH FDA TITLE 21 FOR FOOD CONTACT, AND HAVE A MAXIMUM
WORKING PRESSURE OF 2000 PSI.
ALL PIPING, REGULATORS, AND PRESSURE REGULATORS SHALL BE KEPT TIGHT TO PREVENT
LEAKAGE OF ANY CO2 GASES, AS PER NFPA 55:7.3.1.3.1 (2018 EDITION)
CO2 SHALL BE EQUIPPED W/ AN EMERGENCY SHUT OFF DEVICE, AS PER NFPA 55:7.3.11
(2018 EDITION)
EXTERIOR
SIDE
BACKROOM
SIDE
SEAL INTERIOR SIDE W/ SPRAY FOAM
INSULATION. STUB OUT WALL 6"
ABOVE FINISHED CEILING ROUTE TO
FTN MACHINES. LINE TO BYPASS ALL
ELECTRICAL & MECHANICAL
CONNECTIONS
SEAL EXTERIOR SIDE
W/NP1 CONSTRUCTION
GRADE SEALANT
1 1/2" PVC CHASE
HOSE
WD. TRUSS SYSTEM
HOSE
6"
.
10
'
8
"
T
O
U
N
D
E
R
S
I
D
E
O
F
C
E
I
L
I
N
G
5'
6
"
.
CO2
TANK
SIP WALL
6 5/8" SIP WALL PANEL. SEE SIP VENDOR SHEETS
6" 20ga. METAL STUD AT 16" O.C. WITH BATT INSULATION.
SEE SHEET A1.3 FOR WALL TYPES
3 5/8" 20ga. METAL STUD AT 16" O.C. (WITH BATT INSULATION IF APPLICABLE)
SEE SHEET A1.3 FOR WALL TYPES
3 5/8" 20ga. METAL STUD AT 16" O.C. TO DECK WITH BATT INSULATION.
SEE SHEET A1.3 FOR WALL TYPES
3 5/8" METAL STUD FURRED WALL (WHERE OCCURS) AT 16" O.C.
FIBER CEMENT WAINSCOT/ PILASTER
PRE MANUFACTURED FREEZER/COOLER WALL
SIP PANEL WALL W/ F.R.P. PANELING, SEE KEYNOTES & SHT. A3.2
3/4" FRT. PLYWOOD W/ F.R.P. PANELING,
SEE KEYNOTES 37 & SHT. A3.2
WINDOW TYPE: SEE WINDOWS SCHEDULE SHEET A6.0
DOOR TYPE: SEE DOOR SCHEDULE SHEET A6.0
X
X
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.3
PROJECT NUMBER: 24212
DIMENSIONED FLOOR
PLAN, WALL TYPES,
AND ENLARGED
RESTROOM
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
NUMBER DESCRIPTION
B 1 30"x48" ADA ACCESSIBLE SPACE AT LAV.
B 2 PARTITION
B 3 COUNTERTOP (SUPPLIED BY CK AND INSTALLED BY
OTHERS)
B 4 36"x48" ADA ACCESSIBLE SPACE AT URINAL
B 5 CONVENIENCE HOOKS
B 6
GRAB BAR 1 1/4" 1 1/2" DIAMETER, PROVIDE
ADEQUATE BLOCKING. FOR EXTERIOR WALLS GC TO
UTILIZE BLOCKING PROVIDED IN SIP.
B 7 FLOOR DRAIN, SEE PLUMBING DWGS.
B 8 INSULATED WATER AND DRAIN PIPES
B 9 60" DIA. MIN. CLEAR FOR WHEELCHAIR
B 10 FRP PANEL WALL
B 11 PORCELAIN TILE FLOORS
B 12 STEEL POST, SEE DETAIL 7/A9.1 'A'
B 13 TOILET FLUSH VALVES TO BE ON THE WIDE SIDE OF
STALL
B 14 TOILET PAPER DISPENSER
B 15 SANITARY NAPKIN DISPOSAL
B 16 MIRROR
B 17 SOLID BLOCKING AT WALL FOR ALL MOUNTED
EQUIPMENT
B 18 FLOOR SHALL SLOPE 1% TO DRAIN
B 19 TOILET SEAT COVER DISPENSER
B 22
BABY CHANGING TABLE TO BE INSTALLED BY G.C.
REFER TO SIP DETAIL FOR EXTERIOR WALL
INSTALLATION
B 23 SOAP DISPENSERS
B 24 S.S. TRASH CAN
B 25 CONVENIENCE SHELF
B 26 HAND DRYER
WALL TYPES
GENERAL NOTES
LEGEND
PAINTED SURFACES PREPARATION NOTES
PAINT TYPE SPECIFICATION NOTES
RESTROOMS KEY NOTES
3/16" = 1' 0"
1DIMENSIONED FLOOR PLAN SE
3/8" = 1' 0"
2ENLARGED RESTROOM PLAN SE
3" = 1' 0"
3CO2 CHASE LINE DETAIL
A3.33D
3C
3B
3A
A3.3
4C
A
A
B
B
4D
4A
4B
1 1
2 2
A3.3
2A
2C
2D
A3.2 1B
1A
1D
1C
A3.22D
2A
2B
2C
A3.2
3A
A3.2
4A
3B
3C
3D
4D
4C
4B
A3.1
1A
1B
1C
1D
S008 S008 S008 S008 S008S008S008
S003
S003
S003
S003
S003
S003
S007
S007
R101
B502
A9.1
2
WALK IN
FREEZER
106
STORAGE
ROOM
103
COLD VAULT
105
WALK IN
COOLER
104
MEN'S
RESTROOM
102
BACK ROOM
109
SALES FLOOR
107
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
HALLWAY
111
TRASH CAN
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
A9.1
1
LOTTO
MACHINE
SUNGLASS
& CELL
PHONE
TELE
COM
LOTTO
STAND
(TO FACE OF SIP)
113' 0"
(TO FACE OF SIP)
113' 0"
17 COOLER DOORS
P403
M009
P403
R203
M104
S008 S008 S008 S008 S008S008S008
S003
S003
S003
S003
S003
S003
S007
V201
B501
P411
A9.1
1
TRASH CAN
S008
FE
PLATFORM
R001
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
C02
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
BC
S
CASHIER
108
PREP AREA
110
P411
F.S.
COMMISSARY RACKS
TRASH
TRASH TRASH
RE
A
C
H
I
N
F
R
E
E
Z
E
R
4
D
O
O
R
S
3 SIDED ENDCAP
S007
BC
S
B504
_______
A2.1
2
(QTY. 2)
(BELOW)
(QTY. 2)
(BELOW)
WINE RACK
R006
M012
BACK ROOM
109
18192021
R210
P102P101
P404
O008P311
P301
P301
O007
O008
P102
O007P304
O007P304
O007P304
P307
O008
P301
P301
O008
P404
P309
P311
P306
P106P108
P308P308
P307
P309
P309 P101
P305
P305
P101 P102
P305
P101 P102 P309
P106
P108
P105 P105
P108
P106
P306
P106P108
S007
R008
R007 R007 R007 R007 R007 R007 R007 R007 R007R007R007R007R007R007R007
P401
ABOVE BELOW
R401
P201 P203 P001P002
P403O010P408P202O008
EXTERIOR
ROOF ACCESS
LADDER
CB
T
D
E
S
K
BFP RACK
MOP
BUCKET
F.D.
**
*
E
L
E
C
T
R
I
C
A
L
P
A
N
E
L
C
L
E
A
R
A
N
C
E
A
R
E
A
F.S.
BELOW7 PS 60
ADVANCE
BI
B
B
I
B
B
I
B
B
I
B
B
I
B
V001
V001
V001
V001
**
*
O
V
E
R
H
E
A
D
ST
O
R
A
G
E
V004
V002
V003
V008
F007
F006
F005
B404
B403
B406
B405
B301
B405
V201
B101
B102
B507
B001
B002B505
B002B505B001
B301
B002B505B001
FE
MUGS
12
H
E
A
D
FO
U
N
T
A
I
N
W/
C
U
B
E
D
I
C
E
12
H
E
A
D
FO
U
N
T
A
I
N
W/
C
U
B
E
D
I
C
E
12
H
E
A
D
FO
U
N
T
A
I
N
W/
C
U
B
E
D
I
C
E
COLD CUP
TOWER
(2
)
T
E
A
BR
E
W
E
R
S
CORNELI
US
4 Head
Froster
VIPER
CORNELI
US
4 Head
Froster
VIPER
DOME LIDS
DISPENSER
LIDS
DISPENSER
LIDS
DISPENSER
COLD CUP TOWER
WA
T
E
R
F
I
L
T
E
R
EV
9
3
2
9
4
4
S003
S003
S003
S003
S003
S003
S003
S003
M011
M108
P404
B101
4' NOVELTY CASE
T301
O003
O004
V007
T003
T201
T202T302
T303T304
V005
O010
V006
B603
B603
B603
B603
B603
O002O006
S101
ABOVE
QTY. 4
FI
L
E
CA
B
NE
T
W
O
R
K
I
N
G
RA
C
K
6'
5
4
"
X
3
6
"
X
1
6
"
B
A
S
E
6'
5
4
"
X
3
6
"
X
1
6
"
B
A
S
E
6'
5
4
"
X
3
6
"
X
1
6
"
B
A
S
E
6'
5
4
"
X
3
6
"
X
1
6
"
B
A
S
E
12' 66" X 36" X 19" BASE
12' 66" X 36" X 19" BASE
UC CIG
4' TOBACCO
(54" TALL)
2' CIGS
(54" TALL)
2'
C
I
G
S
(6
4
"
T
A
L
L
)
2' CIGS
(54" TALL)
2'
C
I
G
S
(6
4
"
T
A
L
L
)
2'
C
I
G
S
(6
4
"
T
A
L
L
)
8"
P
E
G
G
E
D
/
SH
E
L
V
E
S
B
E
L
O
W
6" SIDESPLASH
ST
O
R
A
G
E
FL
E
X
SP
A
C
E
FL
E
X
SP
A
C
E
CO
A
T
S
12" PEGGED/SHELVES BELOW
FL
O
O
R
F
A
N
S
P
A
C
E
B
E
L
O
W
HAND
SINK
UNOX OVENW/ HOOD
UNOX OVENRACK
27
P
A
N
E
U
R
O
B
A
K
E
R
Y
C
A
S
E
48
"
R
E
F
R
I
G
E
R
A
T
E
D
WO
R
K
T
A
B
L
E
OR
G
A
N
I
Z
E
R
24
I
N
SM
A
L
L
W
A
R
E
S
CA
B
I
N
E
T
PLASTICTRASH CAN
F.D.
LO
C
K
A
B
L
E
CA
R
T
O
N
ST
O
R
A
G
E
LO
C
K
A
B
L
E
CA
R
T
O
N
ST
O
R
A
G
E
LO
C
K
A
B
L
E
CA
R
T
O
N
ST
O
R
A
G
E
LO
C
K
A
B
L
E
CA
R
T
O
N
ST
O
R
A
G
E
K1
1
5
1
5
12" PEGGED/SHELVES BELOW 12" PEGGED/SHELVES BELOW 12" PEGGED/SHELVES BELOWSCANNERPRINTERMONITOR CASH BOXDNR MONITOR
32" CLEAR FOR SAFE
SCANNER
MO
N
I
T
O
R
CA
S
H
B
O
X
PRINTER
3'
C
I
G
S
(6
4
"
T
A
L
L
)
DESK
MG
R
CO
M
P
U
T
E
R
3
D
R
A
W
E
R
S
PLASTIC
TRASH CAN
3'
C
I
G
S
(6
4
"
T
A
L
L
)
R006
F207
4R
V
Z
C
3
0
T
2
4R
V
Z
C
3
0
T
2
4R
V
Z
C
3
0
4R
V
Z
C
3
0
P102
P102
P101P302 P310P305O007P101
O007P302P305
P310
P304
T101
H401
V105
H201
H202H203
T107
T107
H211
R202H205
H302
T007
T105
T104
T104
R206
T010 T011
T011
T010
T001
T002
T008
T005T009
H301
P403
P404
T003
T004
T006
P204
M107
P403
P402
WOMEN'S
RESTROOM
101
MUGSM011
WIRE RACK
UNOX SPEEDPRO OVEN27" UNDER
COUNTER
FREEZER
P406
MONITOR
KEYBOARD
PR
I
N
T
E
R
T003T001T005
T006T007T002
T004
T008T009
SMART DESK
BE
E
R
T
U
B
30
I
N
X
5
4
I
N
M014
DNR
T012
T106
P413
M016 M016 M016 M016
M016M016M016M016M016M016M016M016M016 M016M016 M016 M016 M016 M016 M016 M016
M001
M001
M001 M001 M001 M001
VE
E
D
E
R
RO
O
T
R102
RAMP
O008 PIPE
CHASE
TO
W
E
L
O005P205
M006
M007
M007
PACKAGED
BAKERY
SHADOWBOX WITH
NESTING TABLES
COFFEE CONDIMENT ISLAND
C001 C107C107C001C001
(3) BREW ON DEMAND UNITS
I.
C
.
C
U
P
/
LI
D
D
I
S
P
.
I.
C
.
C
U
P
/
LI
D
D
I
S
P
.
6"
S
I
D
E
S
P
L
A
S
H
K115155 HEAD
CAPPUCCINO
TE
A
P
A
C
K
E
T
S
RA
C
K
ICED COFFEE
THEATER
NI
T
R
O
CU
P
S
NI
T
R
O
IC
E
MA
C
H
I
N
E
CU
P
S
TOWEL
P204O008C002
C106
P205
C004 C005C202
R310
P403
R309
11' 0" X 4' 0" SOUTHERN CASE ARTS
ISLAND MERCHANDISER
H209H209
O001
H108
H106
H303
H005H001H003
H206
H208
H104
O001
H001H003
O001
O001
H103 B006B006
PIZZA
SPINNER
CONDIMENT
WARM RACK
PIZZA
WARMER
PLATFORM
(2) HOT DOG GRILL
ACRYLIC
BUN
DISPLAY
(2) MICROWAVES
BELOW
4
P
A
N
C
O
L
D
CO
N
D
I
M
E
N
T
BO
T
T
L
E
CO
N
D
I
M
E
N
T
S
PA
C
K
A
G
E
D
BA
K
E
R
Y
36"
FLEXSERVE
HEATED
MECHANDISERS
36"
FLEXSERVE
HEATED
MECHANDISERS
BEV.
COOLER
BEV.
COOLER
A3.3
8 B503
B503
B503
TOWEL
O005
O005
H107
R207
UN
D
E
R
C
O
U
N
T
E
R
RE
F
R
I
G
E
R
A
T
O
R
RICOS
NACHOS
H109H110H111
C111
V004 V004
S003S003
OP
E
N
AI
R
CO
O
L
E
R
12' 36" X 18" X 19" BASEM001
WATER PODS
(MEADOW BROOK)
WATER PODS
(ZEPHYRHILLS)
WATER PODS
(ZEPHYRHILLS)
WATER PODS
(CNF)
WATER PODS
(CNF)
Z001Z001 Z001 Z001 Z001Z001Z001
M101 M101
M102
B003
B003
M002
M105
P309
P403
R007 R007 R007 R007
F207
F207
C109
C109
P309
P103
P103
P104
P104
P305
V105
H207
T108
T109
V101
P414
END UNIT END UNIT END UNIT
END UNITEND UNITEND UNITEND UNIT
EN
D
U
N
I
T
P412
V207 V207
V004
1. SEE SHEET A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT LIST
2. EQUIPMENT SYMBOL
3. VERIFY EQUIPMENT LAYOUT WITH CIRCLE K
4. SEE SHEETS A3.1, A3.2, AND A3.3 FOR INTERIOR ELEVATIONS.
*
.
.
.
.
A REAR
B RIGHT
C FRONT
D LEFT RM.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.4
PROJECT NUMBER: 24212
EQUIPMENT PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
GENERAL NOTES
ROOM REFERENCE ORIENTATION
3/16" = 1' 0"
1EQUIPMENT PLAN SE
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.5.1
PROJECT NUMBER: 24212
EQUIPMENT LIST
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
C STORE EQUIPMENT SCHEDULE A1.5.1
EQUIPMENT
CATEGORY Sub category CK ITEM # ITEM NAME
NOT
SHOWN
IN PLAN USE DESCRIPTION QTY Manufacturer Model
RESPONSIBILTY ELECTRICAL WATER WASTE
REMARKS PR
O
T
O
T
Y
P
E
F
I
N
I
S
H
S
C
H
E
D
U
L
E
SUPPLIED
BY
INSTALLED
BY MEP BY AM
P
S
(
M
C
A
)
Vo
l
t
s
Ph
a
s
e
PL
U
G
DI
R
E
C
T
PL
U
G
&
C
O
R
D
B
Y
G
C
FI
L
T
E
R
E
D
FI
L
T
E
R
&
D
E
S
C
A
L
E
CO
L
D
HO
T
DI
R
E
C
T
IN
D
I
R
E
C
T
BEVERAGE AND ICE FOUNTAIN B001 12 HD SODA FOUNTAIN PACKAGE CORNELIUS FOUNTAIN/ADAPTER/LEGS 3 CORNELIUS ENDURO 300 CK CK GC 5.2 120 V 5 15P X X X 3/4" MAIN TRUNK LINE FROM FILTER, TEE 1/2" LINE W/ BRASS BALL VALVE AND 3/8" FLARE FITTING TO EACH PIECE OF EQUIPMENT
BEVERAGE AND ICE FOUNTAIN B002 CARBONATOR FOR ED300 1 PER FOUNTAIN 3 CORNELIUS *416424000 CK CK GC 7.2 120 V 5 15P X 1/4" FLARE CO2 INLET, 3/8" FLARE WATER INLET, 3/8" FLARE SODA WATER OUTLET. TO BE INSTALLED ON SHELF ON TOP OF BIB RACK
BEVERAGE AND ICE FOUNTAIN B003 TEA BREWER PACKAGE W/ (3) TCN URNS AND SS TRAY 2 WILBUR CURTIS RSTB, (3)TCN, DT24 CK CK GC 13.8 120 V 5 15P X 3/4" MAIN TRUNK LINE FROM FILTER, TEE 3/8" LINE W/ BRASS BALL VALVE, VENDOR TO INSTALL FROM SHUTOFF TO UNIT
BEVERAGE AND ICE COLD B006 BEVERAGE COOLER 2 VARIES VARIES CK CK GC 2.2 115 V
BEVERAGE AND ICE ICE B101 19" FOLLETT REMOTE CHEWBLET ICE ICE MAKER (1800LB) 1 OR 2 FOUNTAINS 2 FOLLETT HCD1810RHT CK CK GC 5.0 120 V 5 15P X X X <MOPD 15A>3/8" WATER LINE FROM SCALE INHIBITOR; 1/2"DRAIN LINE, GC TO PROVIDE CORD AND PLUG NEMA 5 15, REQUIRES DEDICATED 15A CIRCUIT
BEVERAGE AND ICE ICE B102 30" MANITOWOC REMOTE ICE MAKER (1825LB) 1 FOUNTAIN AND/OR BAGGER 1 MANITOWOC IYF 1800C 161 CK CK GC 1.1 120 V 5 15P X X X <MOPD 15A>3/8" WATER LINE FROM SCALE INHIBITOR; 1/2"DRAIN LINE, GC TO PROVIDE CORD AND PLUG NEMA 5 15
BEVERAGE AND ICE ICE REF. B201 REMOTE CONDENSER FOR HCD1818RHT W/ LINE SET CONDENSER FOR ICE MACHINE 2 FOLLETT CK CK GC 15.7 208 V 3 X REFERENCE REFRIGERATON VENDOR DRAWINGS
BEVERAGE AND ICE ICE REF. B202 REMOTE CONDENSER FOR IYF1800C W/LINE SET OPTIONAL 2ND ONE FOR BAGGER 1 MANITOWOC CVDF1800F 263A CK CK GC 20.0 208 V 3 X REFERENCE REFRIGERATON VENDOR DRAWINGS
BEVERAGE AND ICE FROZEN B301 FOUR BARREL COUNTERTOP FCB PACKAGE STANDARD TO BE INSTALLED ON 4" LEGS W/ TALL TRANSLITE 2 CORNELIUS VIPER ELITE 4B CK CK GC 28.8 208 V L630P X X <208/1PH MCA 28.8A/FLA 23.1A/MOCP 30A W/BUCK BOOST>3/4" MAIN TRUNK LINE FROM FILTER, TEE 1/2" LINE W/BRASS BALL VALVE AND 3/8" FLARE FITTING TO EACH PIECE OF EQUIPMENT;
30PSI MIN. GC TO DO ELECT. ONLY
BEVERAGE AND ICE DISPENSERS B403 COUNTERTOP CUP/LID DISPENSER CUPS LEFT 1 GENERUX FINE W.P. CUSTOM CK CK
BEVERAGE AND ICE DISPENSERS B404 COUNTERTOP CUP/LID DISPENSER CUPS RIGHT 1 GENERUX FINE W.P. CUSTOM CK CK
BEVERAGE AND ICE DISPENSERS B405 COUNTERTOP FCB DOME LID DISPENSER 2 FOOD CONCEPTS CK DOMELID CK CK
BEVERAGE AND ICE DISPENSERS B406 COUNTERTOP LID/STRAW DISPENSER 1 FOOD CONCEPTS CK DISLIDST FOUNT CK CK
BEVERAGE AND ICE MISC. B501 CO2 TANK 1 CARBOMIZER VARIES VENDOR VENDOR VENDOR
BEVERAGE AND ICE MISC. B502 CO2 CABINET 1 ROYSTON CUSTOM CK CK
BEVERAGE AND ICE MISC. B503 CO2 DETECTION SYSTEM X 1 LOGICO2 MK9 VENDOR VENDOR VENDOR 1.0 120 V 5 15P PROVIDED AND INSTALLED BY CO2 VENDOR, GC TO PROVIDE A SINGLE OUTLET ONLY NEAR THE BIB RACKS.
BEVERAGE AND ICE MISC. B504 CO2 SIGNS X 1 NUCO2 VENDOR VENDOR
BEVERAGE AND ICE MISC. B505 LEG SHROUD FOR ENDURO300 FOUNTAIN X ONE PER FOUNTAIN UNIT 3 FOOD CONCEPTS CK FTN ENDUROSHRD CK CK
BEVERAGE AND ICE MISC. B507 LEG SHROUD FOR FCB X ONE PER FCB 2 FOOD CONCEPTS CK FTN FCBSHROUD CK CK
BEVERAGE AND ICE BIB B603 3 WIDE BIB RACK PACKAGE PACKAGE WITH 5 SHELVES AND PUMP MOUNT 5 CORNELIUS 3BIFJ CK CK FOUNTAIN RACKS ARE PREASSEMBLED WITH SHELF AND PUMPS ALREADY MOUNTED. FCB AND OTHER REQUIRE ASSEMBLY AND PUMPS TO BE PROVIDED AND/OR MOUNTED BY CONTRACTOR.
COFFEE BREWERS C001 3 HOPPER BEAN TO CUP BREWER 3 SCHAERER 040381 00058EUS CK VENDOR GC 16.0 208 V L620P X X SCHAERER CHECKLIST MUST BE COMPLETE L6 20R 250VAC, 20AMP, 1 PHASE, RANGE 205 240V, 20AMP BREAKER, 3" HOLE PER BREWER, 3/8" COMPRESSION SHUTOFF, 30 60PSI PRESSURE; HUB,
WATER AND POWER 36" FROM MACHINE LOCATION
COFFEE BREWERS C002 5 HD CAPPUCCINO 1 WILBUR CURTIS PCGT5 CK CK GC 15.0 120 V 5 15P X 3/4" MAIN TRUNK LINE FROM FILTER TO COFFEE BAR, TEE 1/2" LINE W/ BRASS BALL VALVE AND 1/4" FLARE FITTING TO EACH PIECE OF EQUIPMENT; SINGLE OUTLET
COFFEE BREWERS C003 BEAN TO CUP COFFEE WATER FILTER X ONE PER SET OF (3) BEAN TO CUP BREWERS 3 SCHAERER HF40 S CK VENDOR VENDOR X
COFFEE COND/MISC. C004 COLD DRAFT COFFEE DISPENSER COLD DRAFT COFFEE DISPENSER 1 BUNN NITRON COLD DRAFT
C TOP 4:1 12:1 WITH
REMOVABLE DOOR
GRAPHIC
CK CK GC 6 120 V 1 NEMA 5 15
P
COFFEE COND/MISC. C005 COLD BREW COFFEE DISPENSER COLD BREW COFFEE DISPENSER 1 BUNN NITRON COLD DRAFT
ALL NITRO W/RDG &
NGM
CK CK GC 6 120 V NEMA 5 15
P
COFFEE COND/MISC. C106 TEA RACK 1 PURELEAF CK PURELEAF RACK 6 D
S
CK CK
COFFEE COND/MISC. C107 ICED COFFEE CUP/LID DISPENSER 2 LIBERTY CUSTOM CK CK
COFFEE COND/MISC. C108 4HD COFFEE CREAMER 1 DANONE ID 400 VENDOR CK GC 2.8 120 V 5 15P
COFFEE COND/MISC. C111 REFRIGERATED COLD PANS NSF 7 REFRIGERATED COLD PANS 1 WELLS RCP 7200 CK CK GC 4.9 115 V NEMA 5 15
P
REFERENCE TO CABINET VENDOR DRAWINGS
COFFEE COND/MISC. C202 ICE AND WATER DISPENSER ICE AND WATER DISPENSER 1 FOLLETT 15CI100A NW NF ST 00
15 SERIES CHEWBLET ICE
MACHINE AND WATER
DISPENSER
CK CK GC 5.0 115 V
DECOR CATEGORIES D001 COFFEE BACKGROUND DÉCOR X INCLUDES WALL PANEL AND LETTERS 1 CUSTOM CK CK WALL COVERING OR ACRYLIC PANEL AND LETTERING
DECOR CATEGORIES D002 POLAR POP DÉCOR PACKAGE X INCL. PP SIGN & HEADER PANELS 1 CUSTOM CK CK INCLUDES HANGING SIGNAGE, COIN FOR POLAR POP
DECOR CATEGORIES D003 FROSTER DÉCOR PACKAGE X INCL. FROSTER SIGN, HEADER PANELS & FRAMES 1 CUSTOM CK CK INCLUDES HANGING SIGNAGE, COIN FOR FROSTER
DECOR CATEGORIES D005 HOT FOOD DÉCOR PACKAGE X INCLUDES WALL PANEL AND LETTERS 1 CUSTOM CK CK INCLUDES HANGING SIGNAGE, COIN FOR FROSTER
DECOR CATEGORIES D006 GRILL DÉCOR & POP PACKAGE X INCLUDES GRILL DRAWER KITS 1 CUSTOM CK CK INCLUDES ALL DECOR AND SINGNAGE NEEDED FOR HOT FOODS AREA
DECOR POP D101 24"X36" BACKLIT LED FRAMES 1 CUSTOM CK CK GC 120 V 5 15P BACKLIT SNAP FRAMES FOR POP AND MENUS
DECOR COLD D201 COOLERWALL DÉCOR PACKAGE X INCLUDES HEADER PANELS & ICONS 1 CUSTOM CK CK INCLUDES BUTTONS FOR ABOVE COOLER DOORS
DECOR COLD D202 FREEZER WALL DÉCOR PACKAGE X INCLUDES HEADER PANELS & ICONS 1 CUSTOM CK CK INCLUDES BUTTONS FOR ABOVE COOLER DOORS
DECOR COLD D203 COLD VAULT SIGN BACKLIT 1 CUSTOM CK CK GC 120 V 5 15P BACKLIT COLD VAULT LETTERING
DECOR COLD D204 COLD VAULT GRAPHICS PACKAGE X 1 CUSTOM CK CK INCLUDES ALL DECOR AND SINGNAGE NEEDED FOR BEVERAGE CAVES INCLUDING COLD VAULT WALL COVERING
DECOR CENTER D301 CENTER STORE HALO ELEMENT MERCHANDISING (TAKE IT
EASY)
X HALO & LETTERS 1 CUSTOM CK CK SUSPENDED ELEMENT AND WORD COPY NO POWER REQUIRED
DECOR CENTER D302 CENTER STORE HALO ELEMENT CHEKCOUT (PAY HERE/NICE TO
SEE YOU)
X HALO & LETTERS 1 CUSTOM CK CK SUSPENDED ELEMENT AND WORD COPY NO POWER REQUIRED
DECOR CENTER D303 CENTER STORE HALO ELEMENT FOOD (GOOD TO GO) X HALO & LETTERS 1 CUSTOM CK CK SUSPENDED ELEMENT AND WORD COPY NO POWER REQUIRED
DECOR CENTER D304 RESTROOM DÉCOR SIGNS X 1 CUSTOM GC CK GC 120 V 5 15P RESTROOM SIGN ON BULKHEAD ABOVE COORIDOR AND RESTROOM ENTRANCE
FUEL & FORCOURT FUEL F001 FUEL TANKS X 1 FS/XERXES/MODERN CUSTOM CK PETRO
FUEL & FORCOURT FUEL F002 FUEL DISPENSERS X 1 GILBARCO 700S CK PETRO PETRO X X REFR TO PETRO PLANS FOR ELECTRICAL REQUIREMENTS
FUEL & FORCOURT FUEL F003 PETROLEUM EQUIPMENT AND PIPING X 1 ANS VARIES CK PETRO PETRO
FUEL & FORCOURT FUEL F004 SUBMERSIBLE TANK PUMPS (STP)X 1 RED JACKET VARIES CK PETRO PETRO X X REFR TO PETRO PLANS FOR ELECTRICAL REQUIREMENTS
FUEL & FORCOURT FUEL F005 VEEDER ROOT X 1 VEEDER ROOT TLS 450PLUS CK PETRO PETRO 2.0 115 V X
FUEL & FORCOURT FUEL F006 INTERCOM X 1 3M D2400 PETRO PETRO PETRO 8.0 120 V 5 15P IG QUADRUPLEX OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL. (PROVIDED AND INSTALLED BY PETROLEUM CONTRACTOR)
FUEL & FORCOURT FUEL F007 PUMP CONTROL PANEL 1 FEPETRO STP SCI CK PETRO PETRO 30.0 120 V X
FUEL & FORCOURT SITE F101 CANOPY & INSTALL X 1 JIMCO/ARNING N/A CK CANOPY
FUEL & FORCOURT SITE F102 SITE SIGNAGE X 1 S.R./PATTISON N/A CK SIGN GC X X REFER TO SIGN VENDOR FOR ELECTRICAL REQUIREMENT FOR MID AND BUILDING SIGNS
FUEL & FORCOURT SITE F103 3'x6' ELECTRONIC MESSAGE CENTER (EMC) X 1 ABLE N/A CK SIGN GC 15.0 120 V X REFER TO SIGN VENDOR FOR ELECTRICAL REQUIREMENT FOR MID AND BUILDING SIGNS
FUEL & FORCOURT SITE F104 4'x8' ELECTRONIC MESSAGE CENTER (EMC) X 1 ABLE N/A CK SIGN GC 26.7 120 V X REFER TO SIGN VENDOR FOR ELECTRICAL REQUIREMENT FOR MID AND BUILDING SIGNS
FUEL & FORCOURT MISC. F206 BOLLARD COVERS X 1 POSTGUARD VARIES CK GC/OPS GC. TO ASSEMBLE, OPERATIONS TO PLACE
FUEL & FORCOURT MISC. F207 HOODED TRASH 3 MASONWAYS ARU/TB47
FUEL & FORCOURT MISC. F208 SINGLE SIDED AMENITY UNIT 1 MASONWAYS ARU2
HOT FOODS HOT DOGS H001 50 HOT DOG ROLLER GRILL (DURATIC ROLLS) 2 STAR 50SCBDEP CK CK GC 12.8 120 V 5 15P
HOT FOODS HOT DOGS H002 SLANTED GLASS SNEEZE GUARD FOR STAR 50 GRILL X 2 CREATIVE DISPLAY CDW HT LED 50 CK CK GC 1.0 120 V 5 15P ASSEMBLED BY GC
HOT FOODS HOT DOGS H003 4" BLACK STEEL LEGS HOT DOG GRILLS (WITH RUBBER FEET) (4
PER KIT)
X 2 STAR RGLK KIT CK CK ALL GRILL NEED 4" LEGS, EXTEND ALL THE WAY OUT AND H004 THERMO DRAWER IS INSTALL ON COUNTERTOP UNDER EACH GRILL
HOT FOODS HOT DOGS H005 BUN DISPLAY 1 DESERT STAR CK 10038 CK CK GC 1.2 120 V 5 15P
HOT FOODS HOT DOGS H006 11" LED POP DISPLAY 1 CREATIVE DIPLAY 11 LED POP CK CK GC 1.2 120 V 5 15P
HOT FOODS HOT DOGS H007 HOT DOG GRILL DIVIDER KIT X 1 FOOD CONCEPTS CK RG DK SCBD 50 CK CK GC 1 KIT PER GRILL
HOT FOODS CONDIMENTS H103 4 BIN COLD CONDIMENT DISPENSER DROP IN 1 APW RTR 4DI CK CK GC 3.0 120 V 5 15P STAINLESS STEEL EXTERIOR & FOOD WELLS; HOLDS (6) 1/8 SIZE 4" DEEP PANS (PANS & COVER INCLUDED), CUTOUT FOR COUNTERTOP 16 11/16X 15 11/16
HOT FOODS CONDIMENTS H104 4 BIN COLD CONDIMENT DISPENSER COUNTERTOP 1 APW RTR 4 CK CK GC 3.0 120 V 5 15P STAINLESS STEEL EXTERIOR & FOOD WELLS; HOLDS (6) 1/8 SIZE 4" DEEP PANS (PANS & COVER INCLUDED), CUTOUT FOR COUNTERTOP 16 11/16X 15 11/16
HOT FOODS CONDIMENTS H106 WIRE SAUCES / CONDIMENT RACK 1 WIRECRAFT PMRK0404 CK CK
HOT FOODS CONDIMENTS H107 CORRAL WIDE WITH 3 STEPS CONDIMENT RACK 1 DESERT STAR 10060 CK CK
HOT FOODS CONDIMENTS H108 CONDIMENT CADDY WITH SOLID BASE 1 DESERT STAR 700641 CK CK
HOT FOODS CONDIMENTS H109 3 TIER CHIP RACK RICOS 3 TIER CHIP RACK 1 RICOS #813936 3 TIER CHIP
RACK
CK CK NACHOS TO GO RACK AND 3 TIER CHIP RACK
HOT FOODS CONDIMENTS H110 NACHOS TO GO RACK RICOS NACHOS TO GO RACK 1 RICOS #813035 NACHOS TO GO
RACK
CK CK NACHOS TO GO RACK AND 3 TIER CHIP RACK
HOT FOODS CONDIMENTS H111 CHEESE CUP RACK RICOS CHEEESE CUP RACK 1 RICOS #813034 CHEESE CUP
RACK
CK CK NACHOS TO GO RACK AND 3 TIER CHIP RACK
HOT FOODS HOT FOOD H201 ELECTRIC COMBI OVEN 1 UNOX XAVC 0511 EPR CK VENDOR GC 19.0 208 V 15 20P X X SEE SPEC SHEET FOR POWER SUPPLY & WATER REQUIREMENTS
HOT FOODS HOT FOOD H202 UNOX VENTLESS HOOD X 1 UNOX XAVHC HC11 CK VENDOR GC 0.5 208 V 6 15P SEE SPEC SHEET FOR POWER SUPPLY & WATER REQUIREMENTS
HOT FOODS HOT FOOD H203 UNOX OVEN STAND W/ PAN RACK X 1 UNOX XWVRC 0711 UH CUSTOM CK VENDOR
HOT FOODS HOT FOOD H205 UNOX SPEEDPRO OVEN STAND X FOR USE WHEN STORE ONLY GETS 1 UNOX SPEED
PRO
1 YES GROUP TBD CK CK
HOT FOODS HOT FOOD H206 PIZZA WARMER W/ CIRCLE RACK W/ MOTOR 1 HATCO FSDT 1 CK CK GC 11.8 120 V 5 15P
HOT FOODS HOT FOOD H207 PIZZA WARMER CURVE APPEAL X 1 HATCO FSD CTLH BK CK CK
HOT FOODS HOT FOOD H208 PIZZA WARMER PLATFORM X 1 DESERT STAR 10026 18 CK CK
HOT FOODS HOT FOOD H209 DISPLAY WARMER 2 FLEXESERVE 1000 CK CK GC 13.0 208 V 6 20P
HOT FOODS HOT FOOD H211 UNOX SPEEDPRO OVEN 1 UNOX BAKERLUX SPEED.Pro CK CK GC 18 208 V NOT
INCLUDED
HOT FOODS MISC. H301 FOOD AT SCALE SMALLWARE PACKAGE X ONE PACKAGE PER FOOD CONVENIENCE STORE 1 E TUNDRA VARIOUS CK CK
HOT FOODS MISC. H302 DAYMARK PRINTERS PACKAGE X PART OF SMALLWARES FOR FOOD 1 DAYMARK MATT85 CK CK GC 2.0 120 V 5 15P IG
HOT FOODS MISC. H303 COMMERCIAL MICROWAVE OVEN 2 MENUMASTER MMS10TS CK CK GC 12.5 120 V 5 15P COMMERCIAL GRADE MICROWAVE
HOT FOODS BAKERY H401 LARGE BAKERY CASE 1 JSI CK BAKE FXT017 CK CK GC 3.0 120 V 5 15P
MARKETING FIXTURES CENTER STORE M001 INLINE GONDOLA PACKAGE 1 LOZIER/RPS/ROYSTON PACKAGE CK VENDOR CIRCLE K TO SUPPLY AND GC TO ASSEMBLE AND PLACE
MARKETING FIXTURES CENTER STORE M002 COLD VAULT SHELVING PACKAGE 1 ETALEX QUOTE CK CK ASSEMBLED BY GC
MARKETING FIXTURES CENTER STORE M006 LARGE NESTING TABLE LM TABLE 1 JSI LM TABLE CK CK
MARKETING FIXTURES CENTER STORE M007 SMALL NESTING TABLE SM TABLE 2 JSI SM TABLE CK CK
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.5.2
PROJECT NUMBER: 24212
EQUIPMENT LIST
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
C STORE EQUIPMENT SCHEDULE A1.5.2
EQUIPMENT CATEGORY Sub category
CK
ITEM
#ITEM NAME
NOT
SHOWN
IN PLAN USE DESCRIPTION QTY Manufacturer Model
RESPONSIBILTY ELECTRICAL WATER WASTE
REMARKS PR
O
T
O
T
Y
P
E
F
I
N
I
S
H
S
C
H
E
D
U
L
E
SUPPLIED
BY
INSTALLED
BY MEP BY AM
P
S
(
M
C
A
)
Vo
l
t
s
Ph
a
s
e
PL
U
G
DI
R
E
C
T
PL
U
G
&
C
O
R
D
B
Y
G
C
FI
L
T
E
R
E
D
FI
L
T
E
R
&
D
E
S
C
A
L
E
CO
L
D
HO
T
DI
R
E
C
T
IN
D
I
R
E
C
T
MARKETING FIXTURES CENTER STORE M009 CENTER STORE DISPLAY PLATFORM 1 VARIES VARIES CK CK GC. TO ASSEMBLE, OPERATIONS TO PLACE
MARKETING FIXTURES CENTER STORE M010 FRUIT STAND 1 MOBILE MERCH. K1430/3B MB CK CK GC. TO ASSEMBLE, OPERATIONS TO PLACE
MARKETING FIXTURES CENTER STORE M011 MUG DISPLAY/RACK COUNTERTOP MODEL 2 FOOD CONCEPTS CK FTN RFLMR 2A CK CK
MARKETING FIXTURES CENTER STORE M012 WINE DISPLAY FIXTURE 102" 1 AMERICAN DISPLAY CUSTOM CK CK GC 1.0 120 V 5 15P (2) STANDARD QUAD OUTLETS ON 1 CIRCUIT AT 86" AFF ABOVE WINE FIXTURE SEE PLANS
MARKETING FIXTURES CENTER STORE M014 BEER TUB 30"x54" 1 CREATIVE DISPLAY CUSTOM
MARKETING FIXTURES CENTER STORE M016 COOLER SHELVING PACKAGE 1 BRUEGMANN GROUP CUSTOM CK CK ASSEMBLED BY GC
MARKETING FIXTURES EXTERIOR EQUIPMENT M101 PROPANE PAD OPTIONAL 2 LEER VARIES
MARKETING FIXTURES SERVICES M102 WATER DISPENSER OPTIONAL 1 GLACIER G218 VENDOR VENDOR GC 20.0 120 V 5 20P X X X X EACH MACHINE MUST HAVE DEDICATED 20 AMP RECEPTICLE, (1) 1/2" WATER LINE PER (3) MACHINE 15 PSI MINIMUM, EACH UNIT TO HAVE DEDICATED BALL
VALVE SHUTOFF, INDIRECT DRAIN.
MARKETING FIXTURES SERVICES M104 LOTTERY VENDING UNIT OPTIONAL 1 VARIES VARIES VENDOR VENDOR GC 120 V 5 15P OPTIONAL
MARKETING FIXTURES SERVICES M105 ICE MERCHANDISER OPTIONAL 1 LEER VARIES
MARKETING FIXTURES SERVICES M106 AIR/WATER COMBINED X 1 VENWORKS HYGEIA VENDOR VENDOR GC 30.0 120 V X VENDOR SUPPLIED AND INSTALLED, GC TO RUN ELECTRICAL 3/4" CONDUIT, #10 WIRE W/ GROUND. STUB UP BEHIND PAD. PAD TO BE 60"X36" SEE CIVIL PLANS
MARKETING FIXTURES SERVICES M107 ATM MACHINE 1 TRITON RL5000 CK VENDOR GC 2.0 120 V 5 15P IG DEDICATED ISOLATED GROUND POWER, PHONE LINE, AND DATA LINE
MARKETING FIXTURES SERVICES M108 BITCOIN MACHINE 1 BITCOIN DEPOT 145 V
MARKETING FIXTURES INT MISC. M201 WE ID SIGN X 1 A.B. N/A VENDOR CK GC 1.0 115 V 5 15P PROVIDE SINGLE OUTLET FOR POWER ONLY PER DRAWINGS
MARKETING FIXTURES INT MISC. M202 PUSHER TRAYS, CHANNEL RAILS, PEGS HOOKS X 1 TRION INDUSTRIES VARIOUS CK OPS
MARKETING FIXTURES INT MISC. M203 COOLER GLIDES BY BRUGEMANN X 1 PFI VARIOUS CK OPS
MARKETING FIXTURES INT MISC. M204 POP BACK STRIPS X 1 GLADSON VARIOUS CK OPS
MARKETING FIXTURES INT MISC. M301 SIDEWALK A FRAME SIGNAGE DISPLAY X 1 MAGICMASTER QLA GI CK OPS
MARKETING FIXTURES INT MISC. M302 PUMP APPROACH SNAP FRAMES X 1 KDM POP SOL VARIOUS CK OPS
MARKETING FIXTURES INT MISC. M303 INVERTED PUMP TOPPERS X 1 HICORP DB650SA CK CK
MARKETING FIXTURES INT MISC. M304 BUILDING SNAP FRAMES X 1 VARIES VARIES CK GC
OPERATIONS O001 NAPKIN DISPENSER 4 MCLANE N/A CK OPS COMES FROM MCLANE INSTALLED AT TIME OF OPERATION SETUP
OPERATIONS O002 MANAGER DESK 1 ROYSTON CUSTOM CK VENDOR
OPERATIONS O003 MANAGER CHAIR 1 OFFICE DEPOT LORELL 722306 CK OPS
OPERATIONS O004 TELEPHONE 1 VTECH 532343 CK OPS VENDOR
OPERATIONS O005 PAPER TOWEL DISPENSER TORK 3 TORK 5511282 CK GC PROVIDED BY OPERATIONS, USES REFILL 754374
OPERATIONS O006 SAFETY CABINET OPTIONAL 1 VARIES VARIES CK VENDOR
OPERATIONS O007 TOILET PAPER DISPENSER 6 TORK 555528A CK GC PROVIDED BY OPERATIONS, USES REFILL 638916
OPERATIONS O008 SOAP DISPENSER 7 MCLANE/COREMARK 299743 CK GC PROVIDED BY OPERATIONS, USES REFILL MCLANE 570416
OPERATIONS O009 OPERATIONAL EXCELLENCE PACKAGE X 1 VARIES VARIES CK OPS/CK
OPERATIONS O010 SAFEWORLD CLEANING KIT X 2 SAFE WORLD 429712 CK GC ORDERED BY MARKETING/ OPS FROM MCLANE
OPERATIONS O011 CHEMICAL DISPENSER(S) X 1 DEMA PF651 OR PF652 CK GC SINGLE DISPENSER FOR MOP SINK, DUAL DISPENSER FOR 30COMP AS REQUIRED.
PLUMBING WAREWASH P001 3 COMPARTMENT SINK W/ (2) 18" DRAIN BOARDS FAUCET SEPARATE 1 ADVANCE TAB 9 3 54 18RL CK GC GC X PROVIDE W/ PRE RINSE, OVERFLOW AND ADAPTA FAUCET; PLUMBING HOOK UP BY GC
PLUMBING WAREWASH P002 PRE RINSE UNIT W/ FAUCET 1 KROWNE 17 109W CK GC GC X X WALL MOUNT, BASE FAUCET, 6" WALL BRACKET
PLUMBING RESTROOMS P101 TOILET 6 AMERICAN STAND 3043.001 GC GC GC X TOILET SEAT #5901.100, WAX RING, AND CLOSET BOLTS TO BE PROVIDED WITH TOILET
PLUMBING RESTROOMS P102 TOILET FLUSH VALVE AUTOMATIC HARDWIRED X 6 SLOAN SLOAN 111 ESS 1.28 TMO HW GC GC GC 1.5 120 V 5 15P X
PLUMBING RESTROOMS P103 URINAL 2 AMERICAN STAND K 5016 ER 0 GC GC GC X
PLUMBING RESTROOMS P104 URINAL FLUSH VALVE AUTOMATIC HARDWIRED X 2 SLOAN SLOAN 186 ESS 0.5 TMO HW GC GC GC 1.5 120 V 5 15P X
PLUMBING RESTROOMS P105 RESTROOM VANITY COUNTERTOP 2 ROYSTON CUSTOM CK VENDOR X
PLUMBING RESTROOMS P106 RESTROOM UNDERMOUNT LAVATORY BOWL 4 ROYSTON INTEGRATED GC VENDOR GC X
PLUMBING RESTROOMS P108 HAND SINK FAUCET AUTOMATIC HARDWIRED 4 SLOAN SF 2400 GC GC GC 1.5 120 V 5 15 P X X HARDWIRED; FULL MODEL NUMBER SF 2400 4 PLG TEE CP 0.5GPM MLM IR FCT
PLUMBING MISC SINKS P201 MOP SINK 1 MUSTEE 63M GC GC GC X
PLUMBING MISC SINKS P202 MOP SINK FAUCET 1 AMERICAN STAND. 8344.012 GC GC GC X X
PLUMBING MISC SINKS P203 WALL MOUNTED HAND SINK INCLUDES FAUCET 1 ADVANCE TAB 7 PS 60 CK GC GC X X X
PLUMBING MISC SINKS P204 DROP IN HAND SINK 2 ELKAY OR EQUAL K11515 CK GC GC X X X SINK AND FAUCET SUPPLIED WITH ROYSTON CABINETS
PLUMBING MISC SINKS P205 GOOSENECK FAUCET FOR DROP IN HAND SINK FAUCET HAND SINK WALL MOUNTED 2 CHICAGO FAUCETS 895 317CP CK GC GC X X X SINK AND FAUCET SUPPLIED WITH ROYSTON CABINETS
PLUMBING RESTROOM ACC. P301 ANGLE FRAME MIRROR 4 BOBRICK B 290 GC GC
PLUMBING RESTROOM ACC. P302 ADA HAND RAILS 2 BOBRICK B 5806 GC GC
PLUMBING RESTROOM ACC. P304 WALL MOUNTED SANITARY NAPKIN DISPOSAL
RECEPTACLE
WOMEN'S COMPARTMENTS ONLY 4 BOBRICK B 270 GC GC
PLUMBING RESTROOM ACC. P305 TOILET SEAT COVER DISPENSER 6 BOBRICK B 4221 GC GC
PLUMBING RESTROOM ACC. P306 LAVATORY GAURD FOR HAND SINK 4 TRU BRO 102EZ GC GC
PLUMBING RESTROOM ACC. P307 HORIZONTAL BABY CHANGING STATION OPTIONAL 2 BRADLEY 962 11 GC GC
PLUMBING RESTROOMS ACC. P308 RESTROOM SIGNS 2 LOCKNET TBD GC GC
PLUMBING RESTROOM ACC. P309 COAT HOOK 6 BOBRICK B 212 GC GC
PLUMBING RESTROOMS ACC. P310 CONVENIENCE SHELF 2 BOBRICK B296 18 GC GC
PLUMBING RESTROOMS ACC. P311 HAND DRYER EXCEL 2 EXCEL TA ABS CK GC 7 120 V X INSTALLER TO SET HEAT TO LOW
PLUMBING MISC. P400 FIXED BLADDER TYPE EXPANSION TANK X 1 AMTROL FLEXCON / WATTS
WLILKINS
ST 12 / WH 18 / PLT 12 / XT 18
PLUMBING MISC. P401 ELECTRIC WATER HEATER ELECTRICAL SPECS VARY PER SIZE 1 AO SMITH DRE 52 24 GC GC GC 66.6 208 V X X X SPECS WILL VARY PER ARCHITECTS PLUMBING SCHEDULE PLEASE SEE MANUFACTURER DATA FOR ELECTRICAL AND /OR GAS SPECS
PLUMBING MISC. P402 WATER FILTER 1 EVERPURE EV9437 10 CK GC GC X 1/2" NPT CONNECTION, PROVIDED BY FACILITIES
PLUMBING MISC. P403 FLOOR SINK 7 ZURN Z1901 GC GC GC X PLEASE USE COMPONENTS LISTED WITH FLOOR SINK; P1900 SEMI DONE; GRATE TYPE WILL DEPEND ON LOCATION AND USE, VERIFY WITH CM DURING
SUBMITTALS.
PLUMBING MISC. P404 FLOOR DRAIN W/ TRAP PRIMER 4 WADE 1002STD6.1 GC GC GC X X SATIN NICKEL STRAINER
PLUMBING SANITARY P405 FLOOR CLEANOUT FLOOR CLEANOUT 4 J.R. SMITH 4100 SERIES GC GC GC NICKEL BRONZE TOP. TWIST TO FLOOR ADJUSTMENT
PLUMBING MISC. P406 BACKFLOW PREVENTER INLINE BEVERAGE CHECK VALVE X 1 WATTS SD3 GC GC GC X
PLUMBING MISC. P407 1/4 TURN BRASS SHUTOFF VALVE X 1 FNW OR EQUAL VARIES GC GC GC 1/4 TURN BRASS BALL VALVE REQUIRED FOR ALL SHUTOFFS SIZE AND TYPE WILL VARY FOR APPLICATION, USE LEAD FREE IN INSULATIONS THAT WHERE
WATER IS ATTACHED TO BEVERAGE EQUIPMENT OR DRINKING FOUNTAINS.
PLUMBING MISC. P408 MIXING VALVE 1 ZURN ZW1017XL GC GC GC X X
PLUMBING MISC. P409 CIRCULATION PUMP RECIRCULATION PUMP 1 TACO 003 BC4 GC GC GC 0.43 115 V 1
PLUMBING MISC. P411 ENCASED NON FREEZE HOSE BIB 2 MIFAB MHY 35 GC GC GC X
PLUMBING MISC. P412 RECESSED GREASE TRAP X 1 JENSEN PRECAST JP750G GC GC GC X AHJ DETERMINES SIZE
PLUMBING MISC. P413 DRINKING FOUNTAINS 1 OAISIS PG8ACSLTM GC GC GC 4.6 120 V 5 15P X X ONLY INSTALL IF REQUIRED BY AHJ
PLUMBING P414 WATER PRESSURE BOOSTER PUMP WATER PRESSURE BOOSTER PUMP 1 XYLEM 2AB310HME02
PLUMBING MISC. P415 BACKFLOW PREVENTER RPZ ASSEMBLY 1 WATTS SS009 GC GC GC X ONLY INSTALL IF AHJ REQUIRES
PLUMBING MISC. P416 BACKFLOW PREVENTER DC ASSEMBLY 1 WATTS LF007 GC GC GC X ONLY INSTALL IF AHJ REQUIRES
PLUMBING MISC. P417 FREEZLESS ROOF HYDRANT 1 WOODFORD RHY2 MS GC GC GC X
PLUMBING MISC. P418 TRAP PRIMER 5 SIOUX CHIEF SERIES 695
REFRIGERATION WIC R001 WALK IN COOLER 1 CROWN TONKA CUSTOM CK CK GC
PLUMBING WIC R002 WALK IN COOLER EVAPORATOR 3 HTPG RUSSELL DOE RL6A141DDARE CK CK GC 2.9 120 V X X R404 REFRIGERANT PAGE 15 OF QUOTE
PLUMBING WIC R003 WALK IN COLER REMOTE CONDENSER 1 HTPG RUSSELL DOE RFO4004SEAALNT CK CK GC 27.7 208 V X X R404 REFRIGERANT, 45AMP MOPD DISCONNECT ATTACHED TO CONDENSER RACK
PLUMBING WIC R004 COLD VAULT EVAPORATOR 1 HTPG RUSSELL DOE RE6A204DDARE CK CK GC 3.6 120 V X X R404 REFRIGERANT PAGE 15 OF QUOTE
PLUMBING WIC R005 COLD VAULT REMOTE CONDENSER 1 HTPG RUSSELL DOE RFO300E4SEAALNT CK CK GC 27.7 208 V X X R404 REFRIGERANT, 45AMP MOPD DISCONNECT ATTACHED TO CONDENSER RACK
REFRIGERATION WIC R006 WALK IN METAL DOOR 36" WIDE 2 CROWN TONKA SELF CLOSE OVERLAP CK CK GC
REFRIGERATION REACH IN R007 WALK IN DOORS 30X75 INCLUDES 36" SHELVING 21 ANTHONY 101 CK CK NO HEATERS IN DOOR
REFRIGERATION WIC R008 COLD VAULT DOORS 1 ANTHONY 103B CK CK NO HEATERS IN DOOR
REFRIGERATION WIF R101 WALK IN FREEZER 1 CROWN TONKA CUSTOM CK CK GC
REFRIGERATION WIF R102 WALK IN FREEZER METAL DOOR 36" WIDE 1 CROWN TONKA SELF CLOSE OVERLAP CK CK GC 1.5 115 V X
REFRIGERATION WIF R103 EVAPORATOR WALK IN FREEZER EVAPORATOR 1 HTPG RUSSELL DOE RL6E077DDARE CK CK GC 8.9 208 V 1 X X REFERENCE REFRIGERATON VENDOR DRAWINGS
REFRIGERATION WIF R104 CONDENSER RACKS WALK IN FREEZER REMOTE CONDENSER 1 HTPG RUSSELL DOE RFO300L4SEANT CK CK GC 14.4 208 V 3 X REFERENCE REFRIGERATON VENDOR DRAWINGS
REFRIGERATION REACH IN R202 27" UNDERCOUNTER FREEZER 1 TRUE TUC 27F LP HC CK CK GC 4.0 120 V 5 15P COMES WITH 8' CORD & 3" CASTORS
REFRIGERATION REACH IN R203 4 DOOR GLASS DOOR FREEZER 4 DOOR UNIT 1 Zero Zone 4RHZC30 CK CK GC 13.9 208 V X X
REFRIGERATION REACH IN R204 4 DOOR GLASS DOOR FREEZER CONDENSER 1 HEATCRAFT BCH0008LCAZ CK CK GC 20.0 208 V X X ELECTRIC DEFROST MOPD 20AMP, MCA 20AMP
REFRIGERATION REACH IN R206 48" UNDERCOUNTER REFRIGERATOR 1 TRUE TUC 48 LP HC CK CK GC 2.3 120 V 5 15P
REFRIGERATION REACH IN R207 27" UNDERCOUNTER REFRIGERATOR ORDER WITH 3" CASTERS 1 BEVERAGE AIR UCR 27 014 CK CK GC 2.5 120 V 5 15P TO BE INSTALLED UNDERCOUNTER AT THE HOT DOG ISLAND, MUST ORDER WITH 3" CASTERS
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.5.3
PROJECT NUMBER: 24212
EQUIPMENT LIST
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
C STORE EQUIPMENT SCHEDULE A1.5.3
EQUIPMENT CATEGORY Sub category
CK
ITEM #ITEM NAME
NOT
SHOWN
IN
PLAN USE DESCRIPTION QTY Manufacturer Model
RESPONSIBILTY ELECTRICAL WATER WASTE
REMARKS PR
O
T
O
T
Y
P
E
F
I
N
I
S
H
S
C
H
E
D
U
L
E
SUPPLIED
BY
INSTALLED
BY MEP BY AM
P
S
(
M
C
A
)
Vo
l
t
s
Ph
a
s
e
PL
U
G
DI
R
E
C
T
PL
U
G
&
C
O
R
D
B
Y
G
C
FI
L
T
E
R
E
D
FI
L
T
E
R
&
D
E
S
C
A
L
E
CO
L
D
HO
T
DI
R
E
C
T
IN
D
I
R
E
C
T
REFRIGERATION REACH IN R210 1 DOOR WINE REFRIGERATOR 1 TRUE GDM 26 HC TSL 01 CK CK GC 5.4 120 V 5 15P
REFRIGERATION OPEN R309 ISLAND FRESH CASE 4'X11' NEW SPEC 1 SOUTHERN CASE ARTS 11.2 MDI 3M2P R CK GC GC 2.9 120 V 1 X X 1.24A FOR LIGHTS, 1.70A FOR FANS HARDWIRED
REFRIGERATION OPEN R310 REMOTE CONDENSER FOR SOUTHERN FRESH CASE NEW SPEC 2 CK GC GC 20.9 208 V X X COMES WITH BOTH ISLAND FROM SOUTHERN CASE ARTS, MOPD 30AMPS, R404 REFIGERANT, 7/8 SUCTION LINE, 1/2 LIQUID LINE
REFRIGERATION MISC. R401 BUBBLE TOP ICE CREAM NOVELTY CASE 1 VARIES VARIES VENDOR VENDOR GC 15.0 120 V 5 15P VENDOR PROVIDED
STORAGE WIRE SHELVING S003 18"X 36" WIRE SHELVING UNIT UNIT INCLUDES (4) POSTS AND (4) SHELVES 16 EAGLE 1836VG/P74VG CK CK (4) SHELVES PER SECTION, (4) 72" POLES PER SECTION
STORAGE WIRE SHELVING S007 24"X36" WIRE SHELVING UNIT UNIT INCLUDES (4) POSTS AND (4) SHELVES 5 EAGLE 2436VG/P74VG CK CK (4) SHELVES PER SECTION, (4) 72" POLES PER SECTION
STORAGE WIRE SHELVING S008 24"X48" WIRE SHELVING UNIT UNIT INCLUDES (4) POSTS AND (4) SHELVES 8 EAGLE 2448VG/P74VG CK CK (4) SHELVES PER SECTION, (4) 72" POLES PER SECTION
STORAGE WALL SHELVING S101 18” X 36" WALL MOUNTED WIRE SHELVING KIT KIT INCLUDES (2) BRACKETS & (1) SHELF 4 EAGLE 1836VG/WBI8 VG CK CK KIT COMES WITH (2) WALL END BRACKETS AND (1) SHELF PER KIT;SECURE TO WALL WITH BLOCKING
STORAGE S201 WIRE STORAGE SHELVING CASTER X ENTER (4) PER SHELF AS NEEDED 1 FORTIER FOR/C5PSB CK CK CASTER ONLY ORDER (4) PER SHELF SECTION AS NEEDED
TRANSACTION/CHECKOUT POS T001 EPOS RADIANT PACKAGE 2 NCR XR7 CK VENDOR GC 8.0 120 V 5 15P IG DEDICATED CIRCUIT; INCLUDES POS UNIT, CASH DRAWER, SCANNER, RECIEPT PRINTER, AND ALL CABLES
TRANSACTION/CHECKOUT POS T002 PINPAD PACKAGE X 2 VERIFONE MX915 CK VENDOR GC
TRANSACTION/CHECKOUT T003 UPS FOR POS AND NETWORK RACK BOH 3 TRIPPLITE OMNIVS800 CK VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT POS T004 UPS FOR NETWORK SWITCH X 2 TRIPPLITE BC350 CK VENDOR GC 120 V 5 15P IG DEDICATED SINGLE OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL
TRANSACTION/CHECKOUT POS T005 COIN CHANGER PACKAGE X 2 GLORY GLOBAL MS9003 CK VENDOR GC
TRANSACTION/CHECKOUT POS T006 RECEIPT PRINTER 2 NCR P201F074:T88V CK VENDOR GC
TRANSACTION/CHECKOUT POS T007 LIFT STATION X 2 VERIFONE LIFT CK VENDOR GC
TRANSACTION/CHECKOUT POS T008 COUPON PRINTER X 2 OUTSITE NETWORK APL01001 CK VENDOR GC
TRANSACTION/CHECKOUT POS T009 PINPAD STAND X 2 OUTSITE NETWORK APL0300RC CK VENDOR GC
TRANSACTION/CHECKOUT POS T010 MASHGIN SELF CHECKOUT PACKAGE 2 MASHGIN KIOSK V2.7 CK VENDOR GC 8.0 120 V 5 15P IG DEDICATED OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL
TRANSACTION/CHECKOUT POS T011 GLORY SELF CHECKOUT CASH SYSTEM 2 GLOBAL GLORY CI 10 CK VENDOR GC 3.0 120 V 5 15P IG SHARE DEDICATED OUTLET WITH T010 UNIT
TRANSACTION/CHECKOUT CHECKOUT MISC. T012 DNR 1 TYCO ELECTRONICS MS600596 CK VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT CHECKOUT MISC. T101 SMART SAFE VAULT + TUBE VEND 1 TIDEL SERIES 4 CK VENDOR GC 8.0 120 V 5 15P IG DEDICATED DUPLEX OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL
TRANSACTION/CHECKOUT CHECKOUT MISC. T102 MONEY ORDER 2 HYPERCOM T7E CK VENDOR GC 3.0 120 V 5 15P IG QUADRUPLEX OUTLET WIRED THROUGH SURGE MANGEMENT PANEL
TRANSACTION/CHECKOUT CHECKOUT MISC. T104 24 TICKET LOTTERY DISPLAY X 2 SCHAFER SYSTEMS 24 TMBL CK CK
TRANSACTION/CHECKOUT CHECKOUT MISC. T105 36 GAME UNDERCOUNTER DISPENSER X 1 SCHAFER SYSTEMS 35/36 RHDT CK CK 120 V
TRANSACTION/CHECKOUT CHECKOUT MISC. T106 LOTTO VERIFIER & PRINTER 1 VARIES VARIES VENDOR VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT CHECKOUT MISC. T107 CIG. BACK BAR 7 AMERICAN DISPLAY CUSTOM CK VENDOR GC 120 V 5 15P
TRANSACTION/CHECKOUT CHECKOUT MISC. T108 LIQUOR BACK BAR OPTIONAL 1 ROYSTON CUSTOM CK VENDOR GC 120 V 5 15P
TRANSACTION/CHECKOUT CHECKOUT MISC. T109 DOUBLE ACTING SWING GATE W/ POST 38" OPENING 1 ROYSTON CUSTOM CK CK
TRANSACTION/CHECKOUT BO T201 BACK OFFICE COMPUTER, PRINTER, HANDHELD, AND
ACCESSORIES
1 VARIOUS VARIES CK VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT BO T202 UPS FOR BO PC X 1 TRIPPLITE INTRNT OFFC 500R CK VENDOR GC 120 V 5 15P IG DEDICATED SINGLE OUTLET WIRED THROUGH SURGE MANAGEMENT PANEL
TRANSACTION/CHECKOUT FUEL/CREDIT T301 BACK RACK ACCESSORIES X 1 VARIOUS VARIES CK VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT FUEL/CREDIT T302 SITE CONTROLLER X 1 HP HP705 CK VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT FUEL/CREDIT T303 CREDIT CONTROLLER X 1 NCR EPC4 CK VENDOR GC 120 V 5 15P IG
TRANSACTION/CHECKOUT FUEL/CREDIT T304 TIGER/PANTHER BOX X 1 PANTHER 32FP WEC7 CK PETRO GC 120 V 5 15P IG
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V001 ELECTRICAL PANEL SYSTEM 1 CPI/P.I. CUSTOM CK GC GC POWER INTEGRITY OR EQUIVALENT | SHOP DRAWINGS WILL BE PROVIDED WHEN NEW PANEL SYSTEM BEING USED
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V002 DSL BOX/FRAME RELAY X 1 VARIES CK VENDOR SUPPLIED BY CK, INSTALLED BY NETWORK INSTALLER
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V003 D MARC BOX X 1 VARIES VENDOR VENDOR GC SUPPLIED AND INSTALLED BY LOCAL PHONE COMPANY, COORDINATE WITH CIRCLE K CM FOR CONTACT. GC TO INSTALL GROUNDING LOCATION FOR D MARC
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V004 DOOR CHIME SYSTEM X 4 OPTEX RC 20U CK VENDOR GC 1.5 120 V 5 15P
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V005 SECURITY SYSTEM INSTALLED X INCLUDES DVR AND ALL HARDWARE 1 CBE CBE CK VENDOR GC 120 V 5 15P IG
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V006 NETWORK INSTALLED X INCLUDES ALL WIRING AND SWITCHES 1 CBE CBE CK VENDOR GC 120 V 5 15P IG
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V007 MUSIC SYSTEM INSTALLED X 1 ONKYO TX 8220 CK VENDOR GC 5.0 115 V 5 15P WILL NEED (1) QUAD OUTLET FROM PM PANEL FOR SYSTEM AND AMPLIFIER
VARIOUS AND CONSTRUCTION ELECTRICAL/LV V008 LANDSCAPE CONTROLLER X 1 VARIES VARIES GC GC GC 120 V 5 15P INCLUDES ALL DECOR AND SIGNAGE NEEDED FOR BEVERAGE CAVES INCLUDING COLD VAULT WALL COVERING
VARIOUS AND CONSTRUCTION FIXTURE/FURNITURE V101 METAL CABINETS 1 ROYSTON SEE SHOPS CK VENDOR PAINTED METAL CABINETS WITH LAMINATE ON DOORS AND SOLID SURFACE COUNTERTOP REFER TO SHOP DRAWING AND/OR DETAILS FOR COLOR SPECS
VARIOUS AND CONSTRUCTION FIXTURE/FURNITURE V103 EXTERIOR FIRE EXINGUISHER ENCLOSURE X FORECOURT 7 CATO OR EQUAL CA 105 10 RRC H GC GC 5 OR 10LB DEPENDS ON AHJ
VARIOUS AND CONSTRUCTION FIXTURE/FURNITURE V105 INTERIOR TRASH CAN X 2 ROYSTON CUSTOM CK CK
VARIOUS AND CONSTRUCTION CONST. MATS. V201 FIRE EXTINGUISHER 2 KIDDE OR EQUAL 2A 10B C GC GC 5 OR 10LB DEPENDS ON AHJ
VARIOUS AND CONSTRUCTION CONST. MATS. V202 INTERIOR LIGHTING X 1 FSG/RLA CREE CK GC GC
VARIOUS AND CONSTRUCTION CONST. MATS. V203 EXTERIOR SITE LIGHTING X 1 FSG/RLA CREE CK GC GC
VARIOUS AND CONSTRUCTION CONST. MATS. V204 CANOPY LIGHTING X 1 FSG/RLA CREE CK CANOPY PETRO
VARIOUS AND CONSTRUCTION CONST. MATS. V205 CONDENSER RACKS (ALL) COOLERS, ICE & REMOTE CASES 1 PRECISION ALU. CUSTOM GC GC CONTACT PRECISION ALUMINIUM PRODUCTS, WWW.ACSTANDS.COM, (954) 480 6919
VARIOUS AND CONSTRUCTION CONST. MATS. V207 36" AIR CURTAIN OPTIONAL 2 MARS AIR STD236 1U CK GC GC 6.4 115 V 1 X VERIFY LOADS WITH MECHANICAL SCHEDULES
VARIOUS AND CONSTRUCTION CONST. MATS. V208 60" AIR CURTAIN OPTIONAL 1 MARS AIR STD260 2U CK GC GC 12.75 115 V 1 X VERIFY LOADS WITH MECHANICAL SCHEDULES
VARIOUS AND CONSTRUCTION CONST. MATS. V212 NICHIHA PANEL SYSTEM PACKAGE 1 NICHIHA CUSTOM CK GC CK TO ORDER
VARIOUS AND CONSTRUCTION CONST. MATS. V213 INTERIOR TILE PACKAGE 1 DALTILE CUSTOM CK GC TILE PACKAGE INCLUDES RONDEC SCHLUTER, QUADEC SCHLUTER, ALL TILE, THINSET AND GROUTING MATERIALS
VARIOUS AND CONSTRUCTION V501 OXBLUE CONSTRUCTION CAMERA X 1 OXBLUE CUSTOM CK GC GC 120 V 5 15P GC TO PROVIDE POLE AND TEMP POWER FOR EXTERIOR CAMERA AND TEMP POWER FOR INTERIOR CAMERA FOR THE DURATION OF CONSTRUCTION
MARKETING FIXTURES EXTERIOR EQUIPMENT Z001 WATER PODS X 5 FOLLETT DB650SA CK OPS
10' 6"
B.O. CANOPY
A
A
B
B
1 1
2 2
26' 8 1/2"
9' 0"9' 0"
HEADER
10' 6"
10' 6"
8' 0"7' 8"
ACT 4
ACT 3
CB1CB1
PREFAB
WALK IN
FREEZER
106
COLD VAULT
105
STORAGE
ROOM
103
WALK IN
COOLER
104
PREP AREA
110
CASHIER
108
SALES FLOOR
107
HALLWAY
111
MEN'S
RESTROOM
102
10' 8"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
1'
3
"
CB1
(TO FACE OF SIP)
113' 0"
(TO FACE OF SIP)
113' 0"
A9.2
10
7
A9.2
______9
A9.2
______
5
A9.2
______
5
A9.2
______
5
A9.2
______
A9.2
11
C 5
C 4
C 18
C 16
C 10C 10
C 10C 10
C 10C 10
C 19
C 12
C 22
C 20
C 12
C 15C 15C 15
C 5
C 21
C 14
C 13
C 13
C 9
C 9 C 9
CB1
10' 10"
?
2'
6
"
8
A9.2
______
10' 6"
2'
8
1
/
2
"
ACT 1
10' 0"
PREFAB
C 14
8
21
C 14
9
7
A9.2
______
10' 8"
C 20
C 10C 10
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
3
CB11
C 2
C 8
P3
P3
P3
C 10C 1016
14 13
2
C 8
15
CB1
P3 C 8
P2
7' 9"
℄OF SOFFIT
℄
C 14
10' 10"
EXTERIOR
ROOF ACCESS
LADDER
C 19
P2 P2
ACT 4
ACT 4
ACT 4
ACT 4
1' 9" EQ EQ
1'
3
"
10' 6"
10' 10"
10' 10"
10' 10"10' 10"10' 10"
C 17
C 17
C 20
C 17
ACT 1
C 17
10' 8"
C 17
C 17
C 19
C 17
C 17
C 15
C 15
C 10C 10
C 17
10' 10"
C 10C 10
2
A8.1
______
9
A9.2
______
8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2" 8' 2"
EQ EQC 7 C 9 C 5 C 6C 23C 23
CB1
P2
12' 2"
B.O. CANOPY (PAINT TOASTY)
C 16
ACT 1
10' 8"
7
2' 10"
1'
1
"
1
'
1
"
2' 10"
ACT 1
C 20
3
A1.6
______
3
A1.6
______
SIM.
C 24
C 24
C 24
17
'
6
1
/
2
"
10' 10"
8
A9.2
______
CB1
6
C 9 C 9 C 9 C 1
C 9
10
C 4
5
11
4
12
2'
2
"
EQ EQ
EQ
E
Q
E
Q
E
Q
EQ. 4' 10 1/2" EQ. EQ. 4' 10 1/2" EQ.
C 20
C 17
C 11
C 11
C 11
C 11
3'
2
1
/
2
"
C 14PREFAB
1' 9"
C 2
C 2
WOMEN'S
RESTROOM
101
C 15
C 6
EQ
E
Q
EQ
BACK ROOM
109
ACT 1
8"
STARTING TILE
EMERGENCY BATTERY
BACKUP LIGHT FIXTURE
CAMERA LOCATION
SUPPLY AIR DIFFUSER
EXHAUST FAN
CEILING ELECT. OUTLET
ILLUMINATED EXIT SIGN2'
CEILING TYPE
CEILING HEIGHT
SUSPENDED GRID, REFER
TO ROOM FINISH SCHEDULE
SHEET A1.2
2'
5/8" GYP. BD. CLNG.
2 X 4 LED LIGHT FIXTURE
(PARABOLIC)
2 X 4 N.I. & EMERG. LED
LIGHT FIXTURE
XX
MOISTURE PROOF FIXTURE
SUPPLIED BY COOLER MFR.
RECESSED OR SUSPENDED
CAN LIGHT FIXTURE
EXTERIOR WALL MOUNT
LIGHT FIXTURE
LED TRANSFORMER FOR
INTERIOR SIGNAGE ABOVE
CEILING
LED
x
2 x 2 LED LIGHT FIXTURE
2 x 2 N.L. & EMERG. LED
LIGHT FIXTURE
EMERGENCY RECESSED OR
SUSPENDED CAN LIGHT
FIXTURE
EXTERIOR EMERGENCY
WALL MOUNT LIGHT
FIXTURE
RETURN AIR GRILLE
EMERG. MOISTURE PROOF
FIXTURE SUPPLIED BY COOLER
MFR.
SURFACE FIXTURE SUPPLIED BY
CIRCLE K/ INSTALLED BY GC
10
5
/
8
"
2
3
/
4
"
LOPRO TRANSOM MOUNTING BRACKET
(PART NUMBER J0041) BY MFR W/ (3) #12
HEX HEAD TEK SCREWS INTO
STOREFRONT MULLION
PROVIDE COMBINATION SIDE EXTENSION
PLATES AS REQUIRED (B0020)
(2) 3/8" BOLT , WASHER & NUT TO
BRACKET IN PREDRILLED HOLE
LOCATIONS @ EA. END OF HOUSING
AIR CURTAIN, CENTER OVER
OPENING. SEE MECH. MAX
WEIGHT #150LBS
STOREFRONT
MULLION (20GA MIN)
STOREFRONT DOOR
SPANDREL GLASS WHEN
WE HAVE AIR CURTAIN
1. SEE FINISH SCHEDULE ON SHEET A1.11 FOR FINISHES
2. DIMENSIONS FOR LIGHT FIXTURE LOCATIONS ARE TO CENTERLINE OF FIXTURE UNLESS
OTHERWISE NOTED.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.6
PROJECT NUMBER: 24212
REFLECTED CEILING
PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
NUMBER DESCRIPTION
C 1 ROOF ACCESS LADDER, SEE DET. 7/A8.3
C 2 NICHIHA FIBER CEMENT WALL PANEL SYSTEM. COLOR TO MATCH SW 6095 TOASTY
C 4 GYP. BOARD VALANCE ABOVE COOLER, FINISH SAME AS ADJACENT WALL. SEE DET.
5/A9.2.
C 5 SOFFIT LINE. SEE DETAILS 9/A9.2
C 6 CONT. FRY REGLET VENT DCS 625 V 600. SEE DET. 2/A8.3
C 7 1' 8" X 2' 6" CEILING ACCESS DOOR PAINT TO MATCH SOFFIT, SEE DETAIL 2/A8.1
C 8 ILLUMINATED EMERGENCY EXIT SIGN. SEE ELECTRICAL
C 9 EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS AND EXTERIOR ELEVATIONS
C 10 SUSPENDED CEILING SYSTEM. SEE DETAILS 10/A9.2 & 11/A9.2.
C 11 EMERGENCY BATTERY BACKUP LIGHT. SEE ELECTRICAL.
C 12 24"x24" ACCESS PANEL ABOVE COOLER DOOR.
C 13 MECHANICAL TOP UNIT ABOVE ROOF SHOWN FOR REFERENCE ONLY, SEE
MECHANICAL AND ROOF PLAN
C 14 EVAPORATORS, SEE MECH.
C 15 EQUIPMENT BELOW, SHOW FOR REFERENCE ONLY.
C 16 RECESSED LIGHT, SEE ELECT.
C 17 LED LIGHT FIXTURE, SEE ELECT.
C 18 GC TO COORDINATE WITH DECOR VENDOR FOR THE COFFEE WALL LIGHTING.
C 19 LINE OF STORAGE LOFT SHELF, SEE DETAIL 4/A9.2
C 20 SURFACE LIGHT, SEE ELECT
C 21 PIPE CHASE
C 22 WALL MOUNTED SOFFIT SYSTEM BY BRAND VENDOR
C 23 EXTERIOR EMERGENCY LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS AND EXTERIOR
ELEVATIONS
C 24 LINE OF MATERIAL CHANGE
3/16" = 1' 0"
1REFLECTED CEILING PLAN
GENERAL NOTES
1 1/2" = 1' 0"
3AIR CURTAIN SECTION AT STOREFRONT
TYPE DESCRIPTION
ACT 1 SUSPENDED 2'x2' GRID WITH 1/2" THK WASHABLE LAY IN VINYL CLAD SHEET
ROCK TILE (WHITE)
ACT 2 NOT USED
ACT 3 SUSPENDED 2'x2' GRID WITH 1/2" THK WASHABLE LAY IN VINYL CLAD SHEET
ROCK TILE (ORANGE)
ACT 4 SUSPENDED 2'X2' GRID WITH FINE FISSURED (WHITE) 2X2 LAY IN ACOUSTICAL
CEILING TILES. SEE PAINT SPECS ON SHEET A1.11
CB1 5/8" GYP. CEILING BOARD, SEE PAINT SPECS ON SHEET A1.11
PREFAB PREFABRICATED INSULATED COOLER PANELS BY COOLER/FREEZER
MANUFACTURER
LEGEND
N.T.S.
2NOT USED
KEYNOTES
CEILING TYPES
A
A
B
B
1 1
2 2
(TO FACE OF SIP)
113' 0"
(TO FACE OF SIP )
113' 0"
SINGLE PLY SYSTEM:
TPO (THERMOPLASTIC POLYOLEFIN MEMBRANE)
ROOFING SYSTEM OVER RIGID INSULATION, WHITE
MECHANICALLY FASTENED.
SOLAR REFLECTANCE: .77
THERMAL EMITTANCE: .87
3'
0
"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
TYP.
D 15
11' 2"
D 27WALK IN
FREEZER
CONDENSING
WALK IN
COOLER
CONDENSING
COLD VAULT
CONDENSING
D 2D 2
D 10
D 9
D 12
D 18
D 7
D 17 D 8
D 6
D 10
D 18
D 9
D 9
ICE
MACHINE
CONDENSING
ISLAND SANDWICH
CASE
CONDENSING
3
A8.3
______
3
A8.1
______
3
A8.1
______
3
A8.1
______
5
A8.3
______3
A8.3
______3
A8.1
______
7' 3 1/2" 31' 9 5/8"
D 4
D 17
EXTERIOR
ROOF ACCESS
LADDER
3
A8.3
______
T.O. PARAPET
18' 6"
19' 4"
3
A8.1
______
3
A8.3
______
4'
9
5
/
8
"
3
A8.1
______
TYP.
D 14
3
A8.3
______
3
A8.1
______
2'
6
"
TYP.
D 3
TYP.
D 14
D 17
D 2D 2
(TO FACE OF SIP )
46
'
0
"
TYP.
D 14
T.O. TOWER
23' 0"
4
A8.3
______
11
A8.3
______
ZERO ZONE
FREEZER
CONDENSING
D 18
39' 1 1/8" 43' 7 3/4" 30' 3 1/8"
ICE
MACHINE
CONDENSING
ICE
MACHINE
CONDENSING
11
'
8
"
50' 1" 17' 5" 44' 4"
TYP.
D 15
TYP.
D 3
D 4
D 21
D 20D 20
D 24
D 20
TYP.
D 20
1
A4.0
______1
A4.0
______
3
A4.0
______
3
A4.0
______
4
A4.0
______
4
A4.0
______
SL
O
P
E
1
/
4
"
/
1
'
0
"
SL
O
P
E
1
/
4
"
/
1
'
0
"
SL
O
P
E
1
/
4
"
/
1
'
0
"
T.O. TOWER
23' 0"
T.O. ROOF PANEL
17' 3 3/4"
T.O. ROOF PANEL
17' 4"
10' 2 5/8"
23' 10"
S L O P E 1 /2 " / 1 ' 0 "SLOPE 1/2" / 1' 0"
D 17
D 22
7' 3 1/2"
48' 10" 9' 0 1/2"
T.O. PARAPET
18' 6"
D 1
D 21
T.O. PARAPET
18' 6"
T.O. PARAPET
18' 6"
T.O. TOWER
21' 6"
T.O. TOWER
21' 6"
4'
1
1
"
8' 9"
T.O. PARAPET
18' 6"
22' 11 5/8"
D 18
3' 10" 7' 8"
T.O. TOWER
23' 0"
T.O. PARAPET
18' 6"
T.O. PARAPET
18' 6"
T.O. TOWER
21' 6"
T.O. TOWER
21' 6"
D 3 D 3
D 16
D 16
D 16
D 26
1
/
4
"
-
1
'-
0
M
I
N
.
S
L
O
P
E
1/4" -1'-0 MIN.
SLOPE
D 3
D 3D 16
1' 0"10"2' 0" 22' 10"
22' 10" 2' 0"
10"
1' 0"A8.3
9
A8.3
12
3'
4
1
/
2
"
5'
4
"
11' 0 3/8"
CONCRETE FOOTING, SEE
STRUCTURAL DRAWINGS FOR
SPECIFIC INFORMATION
SIP WALL PANELS REF. SIP
VENDOR SHEETS
ROOF DRAIN LEADER,
SEE PLUMBING FOR SIZECONCRETE SLAB,
REF. STRUCT
NICHIHA CEMENT WALL PANEL
WAINSCOT. INSTALL PER MFR.
REQUIREMENTS
WATER RESISTIVE BARRIER
1/2" EXPANSION
MATERIAL
SPLASH BLOCK
PER ELEV.T.O. PARAPET
CONTINUOUS 2X TREATED
BLOCKING AS PART OF SIP WALL PANELS, SEE SIP VENDOR
SHEETS
SLOPE 3/4"
PER FOOT
PRE FINISHED
METAL FASCIA, RE:
EXT. ELEVATIONS SEALANT, TYP.
TPO ROOFING TO CONTINUE UNDERNEATH OF
METAL FASCIA AND RUNNING DOWN OVER PARAPET
FRAMING. INSTALL PER MFR REQUIREMENTS.
REFER TO SIP SHEETS FOR SPACING AND DETAILS.
SIP ROOF
PANEL
SIP WALL PANEL
6 5/8"
10
"
2X6 SPF #2 OR BETTER
AT 24" ON CENTER.REFER TO SIP DWGS.
7/16" OSB SHEATHING ATTACH
W/ ANAILS. REFER TO SIP DWGS.
PRE FABRICATED
WOOD TRUSS @ 32'
O.C.
TPO ROOFING. INSTALL PER MFR
REQUIREMENTS. REFER TO SIP
SHEETS FOR SPACING AND
DETAILS.
CL L
C
CONDENSING UNIT, ATTACH TO CURB PER
EQUIPMENT MANUFACTURER
REQUIREMENTS/SPECIFICATIONS
NOTE: PROVIDE STRAPS AS
REQUIRED
(2)2X4 WOOD NAILERS.
SEE STRL.
4X4 PRESSURE TREATED WOOD
SLEEPER WRAP WITH TPO
SIP ROOF PANEL SYSTEM
FRAMING AROUND PERIMETER
OPENING. SEE SIP SHEETS
VARIES SEE MECH
1. SEE DETAIL 8/A8.3 FOR FLASHING AT PIPE PENETRATIONS.
2. SEE BUILDING ELEVATIONS FOR PARAPET HEIGHTS.
SINGLE PLY ROOFING SPECIFICATION
ELEVATE
TPO 60MIL (THERMOPLASTIC POLYOLEFIN MEMBRANE) MECHANICALLY FASTENED TPO WHITE
ASTM D6878
CLASSIFICATION: UL CLASS: A FM CLASS: 1
45 PSF DESIGN
MAX. SLOPE 1"
DECK: COMBUSTIBLE
INSULATION: 8 3/8" ROOF SIP PANEL W/ RIGID INSULATION. R VALUE R 33
TAPERED INSULATION: FACTORY TAPERED BOARDS FABRICATED TO PRODUCE SLOPE OF 1/4"
PER FOOT. SLOPE TOWARDS DRAIN.
CRICKETS: PROVIDE CRICKETS TAPERED. EDGE STRIPS WHERE INDICATED.
AUXILIARY MATERIALS
SHEET FLASHING: SAME SHEET AS FIELD SHEET
BONDING ADHESIVE: MANUFACTURERS STANDARD BONDING ADHESIVE
METAL TERMINATION BARS: PRE DRILLED STAINLESS STEEL OR ALUMINUM BARS
FASTENERS: FACTORY COATED STEEL FASTENERS AND METAL PLATES MEETING CORROSION
RESISTANCE PROVISIONS OF FMG 4470
MISCELLANEOUS: PROVIDE POURABLE SEALER, PREFORMED CONES, PREFORMED INSIDE AND
OUTSIDE CORNER FLASHING, T JOINT COVERS, TERMINATION REGLETS, AND COVER STRIPS.
WALK WAY PADS: FACTORY FORMED, NON POUROUS, HEAVY DUTY SLIP RESISTANT PADS OR
ROLLS ACCEPTABLE TO MEMBRANE ROOFING SYSTEM MANUFACTURER.
ROOF ASSEMBLY SHALL BE INSTALLED PER MANUFACTURER RECOMMENDATIONS.
PROVIDE PATCH OVER ALL 'T' LAP JOINTS IN THE ROOF.
ROOFING WARRANTY FULL SYSTEM WARRANTY +/ 20 YEAR LIMITED WARRANTY COVERING
MEMBRANE AND MEMBRANE ACCESSORIES.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.7
PROJECT NUMBER: 24212
ROOF PLAN AND
DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
KEYNOTES
GENERAL NOTES
SINGLE PLY ROOFING SPECIFICATION
3/16" = 1' 0"
1ROOF PLAN
1" = 1' 0"
2ROOF DRAIN LEADER
1" = 1' 0"
3PARAPET BRACING DETAIL
1" = 1' 0"
4SLEEPER DETAIL CONDENSERS
NUMBER DESCRIPTION
D 1 METAL ROOF ACCESS LADDER WITH SECURITY DOOR BELOW. SEE DETAIL 7/A8.3
D 2 TPO (THERMOPLASTIC POLYOLEFIN MEMBRANE) ROOFING SYSTEM OVER SIP ROOF
PANEL, WHITE MECHANICALLY FASTENED
D 3 TAPERED DRAINAGE VALLEY CRICKET, MINIMUM SLOPE 1/4" PER. FOOT. SEE DETAIL
4/A8.3
D 4 ROOF TOP HVAC UNIT, SEE MECHANICAL AND SIP. DRAWINGS.
D 6 COLD VAULT CONDENSING UNIT, SEE MECHANICAL DRAWINGS.
D 7 WALK IN FREEZER CONDENSING UNIT, SEE MECHANICAL DRAWINGS.
D 8 WALK IN COOLER CONDENSING UNIT, SEE MECHANICAL DRAWINGS
D 9 ICE MACHINE CONDENSING UNIT (ITEM 16A), SEE MECHANICAL DRAWINGS
D 10
4"x4" PRE TREATED WOOD SLEEPER CONDENSER SUPPORT WITH PROTECTION
PAD. PROVIDE EQUIPMENT STRAPS TO SECURE CONDENSERS TO SLEEPERS, SEE
DETAIL 4/A1.7
D 12 ISLAND SANDWICH CASE CONDENSING UNIT. SEE MECHANICAL.
D 14 PRE FINISHED GALVANIZED METAL FASCIA, SEE EXTERIOR ELEVATIONS AND
DETAIL 3/A8.3
D 15
30" WIDE WALKING PATH FOR EQUIPMENT ACCESS. "ULTRA PLY TPO" WALKWAY
PAD BY FIRESTONE OR EQUAL. INSTALL PER MANUFACTURER INSTRUCTIONS.
VERIFY PATH LOCATION WITH CIRCLE K PROJECT MANAGER.
D 16 PARAPET BRACING AS REQUIRED, SEE DETAIL 3/A1.7 AND SIP VENDOR SHEETS.
D 17 ROOF JACK FOR REFRIGERANT LINE, SEE DETAIL 2/M1.2.1, MECHANICAL AND
ELECTRICAL
D 18 VTR LOCATION, SEE PLUMBING DRAWINGS.
D 20 PRE FAB WOOD TRUSSES, SEE SIP SHEETS.
D 21 TPO ROOF AT PARAPET TYP. SEE DETAIL 3/A8.3 & 10/A8.3
D 22 FREEZELESS ROOF HYDRANT, SEE PLUMBING DRAWINGS
D 24 ZERO ZONE FREEZER CONDENSING UNIT
D 26 DRAFT STOP, SEE DETAIL 1/A8.3
D 27 SATELLITE DISH FOR LOTTERY MACHINE. GC TO COORDINATE WITH CK
CONSTRUCTION MANAGER FOR FINAL LOCATION
A
A
B
B
1 1
2 2
WALK IN
FREEZER
106
STORAGE
ROOM
103 COLD VAULT
105
HALLWAY
111
MEN'S
RESTROOM
102
SALES FLOOR
107
PREP AREA
110
CASHIER
108
BACK ROOM
109
WALK IN
COOLER
104
14
'
1
"
FCO
FCO
8' 11"
F 03
19' 5"
2' 9"
EXTERIOR
ROOF ACCESS
LADDER
CL
CL
CL
CL
CL
CL
F 03
F 01
F 01
F 01
F 01
F 03
2'
2
"
CL 11' 3"
CL
40' 0"
CL
15
'
2
"
41' 4"
F 03
9' 9"
CL
F 03
4'
3
"
9' 8"
F 08
41' 8"CL
CL
A1.8
4
A1.8
5
A1.8
6
A1.8
7A1.8
3
F 04
TYP.
F 06
41' 10"
4'
3
"
F 02
44' 9"
2'
5
"
F 02
48' 0"
55' 5"
62' 11"
8'
1
1
"
6'
2
"
TYP.
F 01
CL
CL
CL
CL
F 06
F 06
TYP.
F 06
TYP.
F 06
TYP.
F 06
TYP.
F 06
WOMEN'S
RESTROOM
101
TYP.
F 06
TYP.
F 06
F 02 F 02CL CL
SL
O
P
E
SL
O
P
E
SLOPE SLOPE SLOPESLOPE
SL
O
P
E
SL
O
P
E
F 08
11
'
0
"
16' 0"
5' 6"
29
'
1
"
CL
CL
CL
CL
CL
14
'
2
"
24' 5"
CL
26
'
8
"
49' 9"CL56' 3"
40' 3"
CL
13
'
3
1
/
4
"
28' 6 1/4"CL
CL
TYP.
F 05
9'
5
"
6
'
1
0
"
8
'
6
"
FCO
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
10
'
7
"
9
'
1
"
9
'
2
"
2' 2 7/8" 1' 11 1/4"
19
'
8
"
20' 2 7/8"
20' 3 1/4"
F 03F 09
TYP.
F 06
TYP.
F 06
TYP.
F 06
F 07
15' 6"CL
1'
2
"
CL
F 03
F 03 CL
A3.1
1
5/8" GYP. BD. ON 3 5/8" 20 GA. METAL
STUDS AT 16" O.C.
(SEE FINISH SCHEDULE AND WALL
TYPES)
REFRIGERANT LINE
SEE MECHANICAL
4" CONDUIT SLEEVE PIPE CUT
FLUSH WITH TOP OF CONRETE SLAB
NOTE:
MECHANICAL CONTRACTOR SHALL INSTALL A 4"
DIAMETER PVC PIPE, SCHEDULE 40, FROM TOP OF SLAB,
DOWN BELOW SLAB, OVER TO DELI CASE AND TERMINATE
AT SLAB WITH PULL STRING AS SHOWN. THE
REFRIGERANT PIPING WILL BE INSTALLED IN THIS PIPE
SLEEVE. CONTRACTOR SHALL PROVIDE LONG RADIUS
TYPE SWEEP ELBOWS. MECHANICAL CONTRACTOR SHALL
COORDINATE WITH GENERAL CONTRACTOR THE TIMING
OF THIS INSTALLATION. PIPING SHALL BE CAPPED AT
OPEN ENDS AS SOON AS IT IS INSTALLED TO PREVENT
DIRT, DEBRIS, AND WATER FROM COLLECTING INSIDE OF
PIPE. COORDINATE TERMINATION POINT AT SLAB WITH
DELI CASE INSTALLATION INSTRUCTIONS. MECHANICAL
CONTRACTOR SHALL COORDINATE ELEVATION OF PIPE
BELOW SLAB WITH PLUMBING UTILITIES.
4" CONCRETE SLAB ON GRADE
OVER VAPOR BARRIER, OVER 4"
AGGREGATE BASE. SEE
STRUCTURE
℄
1. VERIFY ALL SLAB PENETRATION LOCATIONS WITH CIRCLE K PROJECT MANAGER AND
EQUIPMENT
2. CONTRACTOR SHALL ADEQUATELY SEAL ALL FLOOR, WALL AND ROOF PENETRATIONS.
TYP.
F 06
TYP.
F 06
TYP.
F 06
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
GC TO REFER TO MANUFACTURER
SUBMITTAL FOR FINAL STUB UP
DETAIL
2'
0
"
3
'
1
1
"
3
'
1
1
"
3
'
1
1
"
13
'
9
"
F 04
1' 3"
9"
VE
E
D
E
R
RO
O
T
F 03
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.8
PROJECT NUMBER: 24212
FLOOR PENETRATION
PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3/16" = 1' 0"
1FLOOR PENETRATION PLAN
1" = 1' 0"
2DELI ISLAND CONDUIT DETAIL
NUMBER DESCRIPTION
F 01 CONCRETE SLAB, SEE STRUCTURAL FOR REINFORCING
F 02 FLOOR DRAINS, SEE PLUMBING DRAWINGS
F 03 FLOOR SINK, SEE PLUMBING DRAWINGS
F 04 4" CONC. CURB AT ELECTRICAL PANELS
F 05 DOMESTIC WATER POINT OF ENTRY, REF. SHEET P1.1.2
F 06 CONDUIT STUB, SEE ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION.
F 07
CONDUIT & SLEEVE PIPE UNDER SLAB FOR DELI ISLAND REFRIGERANT LINE,
SLEEVE PIPE TO BE CUT FLUSH AND LEVEL WITH SLAB, SEE MECHANICAL
DRAWINGS AND DETAIL 2/A1.8.
F 08 HUB DRAINS, REF. SHEET P1.1.1
F 09 3" CONDENSATE LINE CHASE LARGE SWEEP
KEY NOTES
GENERAL NOTES
3/8" = 1' 0"
4ENLARGED AT CASHIER AREA
3/8" = 1' 0"
5ENLARGED AT HOTDOG AREA
3/8" = 1' 0"
6ENLARGED AT CONDIMENT AREA
3/8" = 1' 0"
7ENLARGED AT ELECTRICAL PANELS
3/8" = 1' 0"
3ENLARGED AT BEER TROUGH
1. VERIFY MUSIC & SPEAKERS LAYOUT WITH CIRCLE K REPRESENTATIVE
2. G.C. TO PULL ALL SPEAKER WIRE FOR STORE & CANOPY
1. SECURITY SYSTEM DESIGNED AND PROVIDED BY CIRCLE K
2. INDICATES APPROXIMATE CAMERA LOCATIONS
3. FINAL CAMERA LOCATIONS TO BE DETERMINED BY CIRCLE K
X
A
A
B
B
1 1
2 2
WALK IN
FREEZER
106
STORAGE
ROOM
103
COLD VAULT
105
HALLWAY
111
MEN'S
RESTROOM
102
WALK IN
COOLER
104
BACK ROOM
109
SALES FLOOR
107
CASHIER
108
PREP AREA
110
1 2
3
9
8
21
EXTERIOR
ROOF ACCESS
LADDER
1314
1516
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
BC
S
BC
S
4R
V
Z
C
3
0
T
2
4
R
V
Z
C
3
0
4R
V
Z
C
3
0
4R
V
Z
C
3
0
T
2
CO2
19
20 17
18
7
5 4
1110
12
6
WOMEN'S
RESTROOM
101
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.9
PROJECT NUMBER: 24212
SECURITY SYSTEM
FLOOR PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
GENERAL NOTES
KEY NOTES
3/16" = 1' 0"
1SECURITY SYSTEM FLOOR PLAN (FOR REFERENCE ONLY)EXTERIOR ENVELOPE SEQUENCING MATRIX
NOTE FOR GC: GC TO WORK WITH CK CM TO CLARIFY IF THE TPO SCOPE IS WITH GC OR PORTER
CONDENSERS / RTU PROVIDED BY CK ●
NON SIP BASED OVERHANGS/CANOPY ● ●
PARAPET COPING ● ●
ROOF PANEL TIE DOWNS ● ●
TPO ROOFING ● ●
TAPERED INSULATION ● ●
CRICKETS / EDGE STRIPS ● ●
GUTTERS/SCUPPERS/OVERFLOW ● ●
ROOFTOP UNIT PENETRATIONS ● ●
ROOFTOP UNIT CURBS ● ●
PARAPET KICKER PANELS ● ●
PARAPET RETURNS ● ●
PARAPET (WHERE INDEPENDENT OF SIP WALL)● ●
SIP BASED OVERHANGS/CANOPY ● ●
ROOF PANELS ● ●
ROOF
FIBER CEMENT PANELS ● ●
FIBER CEMENT PANEL CLIPS/SPACERS ● ●
FIBER CEMENT PANEL FLASHING/ STARTER TRACK ● ●
HORIZONTAL STARTER TRACK (UPSIDE DOWN...● ●
KURASTONE VENEER PIECES UP TO SILL ● ●
KURASTONE WAINSCOT SILL ● ●
WAINSCOT STARTER FLASHING/CLIPS/SPACERS ● ●
WALL FINISH AT EXTERIOR
WOOD BLOCKING AT ROOFTOP PENETRATIONS ● ●
GC TO COORD. WALL/ROOF FINISH
FOR WEATHER TIGHT SEAL
WOOD BLOCKING, UNO IN SIPS PLANS ● ●
WOOD TRUSSES/BRACING ● ●
EXCEPTION RTU/CONDENSER BLOCKING
HANGERS PROVIDED & INSTALLED BY GC
TRUSS HANGERS/CLIPS ● ●
ROOF STRUCTURE
WATER RESISTANT BARRIER AT WALLS ● ●
ELECTRICAL INSTALL AT PRE DRILLED
WIRE CHASE(S)
GC TO COORD ELEC INSTALL
W/SIP VENDOR INSTALLATION
WOOD BLOCKING, UNO IN SIPS PLANS ● ●
GLULAM/LVL HEADERS ● ●
TOP PLATES, UNO IN SIPS PLANS ● ●
TRANSITIONS/INTERSECTION/SPLINED TOGETHER ● ●
PILASTERS ● ●
SIPs LIFTED ONTO BASE ● ●
SILL PLATE ANCHOR BOLTS & SIMPSON STHD 14
HOLD DOWN STRAPS ● ●
ALL OTHER HOLD DOWNS PROVIDED &
INSTALLED BY GC
SILL SEALS ● ●
WALLS
FLOOR SLABS ● ●
FOUNDATION FOOTINGS / STEM WALLS (IF ANY)● ●
FOUNDATIONS GC SIP
CONTRACTOR GC SIP
CONTRACTOR
MATERIAL/ELEMENT PROVIDED BY INSTALLED BY
REMARKS
A
A
B
B
1 1
2 2
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
(TO FACE OF SIP)
113' 0"
(TO FACE OF SIP)
113' 0"
WALK IN
FREEZER
106
STORAGE
ROOM
103 COLD VAULT
105
WALK IN
COOLER
104
BACK ROOM
109
SALES FLOOR
107MEN'S
RESTROOM
102
HALLWAY
111
PREP AREA
110
CASHIER
108
EXTERIOR ROOF
ACCESS LADDER
3
A8.2
______3
A8.2
______
1
A8.2
______
G 02
G 03
G 03
G 01
G 01
G 08G 08
G 07
G 06G 06 G 06G 06
G 03
G 04
G 07
G 01
G 03
G 05
G 12
CS1 CS1
CS1
CS1
G 09
G 03
G 10
G 06G 06G 06
G 03
T1T1
G 06G 06G 06
T1
T1
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
G 10
G 01
CO2
T1
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
1
A8.2
______
G 03
G 11
G 11 G 11 G 11G 11
G 03
G 11
G 11
G 11
G 11
G 11
G 03
PREFAB
G 07
G 11
G 11
WOMEN'S
RESTROOM
101
2'
0
"
2' 0"
G 03
VE
E
D
E
R
RO
O
T
VE
E
D
E
R
RO
O
T
G 03
G 03
USE DETAIL 'A', FLOOR TILE TO METAL COVE SCHLUTER TO WALL
TILE FOR RESTROOMS, HALLWAY AND SALES AREA.
METAL COVE BASE
SCHLUTER, SEE FINISH
SCHEDULE
FRP TILE, SEE FINISH
SCHEDULE
FLOOR TILE, SEE FINISH
SCHEDULE
4"
24" X 24" PORCELAIN TILE FINISH. SEE TILE SPECS ON SHEET A1.11
EXPOSED SEALED CONCRETE, SEE SPECS ON SHEET A1.11
REFRIGERATED FLOOR PANEL AT WALK IN FREEZER .
T1
CS1
PREFAB
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.10
PROJECT NUMBER: 24212
FLOOR FINISH PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3/16" = 1' 0"
1FLOOR FINISH PLAN
1 1/2" = 1' 0"
ADETAIL 'A' METAL COVE BASE
NOTE: SCHLUTER METAL COVE BASE FOR FLOOR TILE AND WALL TILE, SEE
TR03 "INTERIOR FINISH" SPEC. ON SHEET A1.11 AND DETAIL A/A1.10
KEY NOTES
FLOOR TYPES
NUMBER DESCRIPTION
G 01 ALUMINUM THRESHOLD
G 02 START POINT OF TILE PATTERN
G 03 FLOOR DRAIN AND FLOOR SINK, SEE PLUMBING DRAWINGS
G 04 MOP SINK
G 05 4" HIGH CONCRETE CURB FOR ELEC. PANELS & LOW VOLTAGE.
G 06 WATERPROOFING MEMBRANE UNDER 9" AND UP TO WALL 9"
G 07 PROVIDE SCHLUTER "RENO RAMP" FOR FLOOR TILE AND SEALED CONCRETE
TERMINATION, SEE TR08 "INTERIOR FINISH" SPEC. ON SHEET A1.11
G 08 WALK IN FREEZER FLOORING BY FREEZER MANUFACTURER.
G 09
IF NEEDED PROVIDE 4" CONCRETE HOUSEKEEPING PAD ABOVE SIDEWALK UNDER
ELECTRICAL CABINET, COORDINATE SIZE AND LOCATION PAD AND CABINET WITH
ELECTRICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS FOR SPECIFIC
INFORMATION
G 10 PROVIDE SOFT MOVEMENT JOINT LOCATION IN CERAMIC TILE FLOOR PER TCNA
HANDBOOK DETAIL EJ171, EVERY 20 TO 25 FEET BOTH DIRECTIONS
G 11 FLOOR OUTLET, SEE FLOOR PENETRATION PLAN SHEET A1.8 AND ELECTRICAL
DRAWINGS.
G 12 3" CONDENSATE LINE CHASE, SEE FLOOR PENETRATION PLAN SHEET A1.8
1. INTERIOR FINISHES & DRYWALL FINISHING LEVELS
2. WALL/CEILING BOARD FINISH LEVEL
FINISH PANELS TO LEVELS INDICATED BELOW, ACCORDING TO ASTM C 840, FOR
LOCATIONS INDICATED:
LEVEL 1 CONCEALED AREAS : EMBED TAPE AT JOINTS IN CEILING PLENUM, BACK
OF HOUSE AND OTHER CONCEALED AREAS UNLESS A HIGHER LEVEL OF FINISH IS
REQUIRED FOR FIRE RESISTANCE RATED ASSEMBLIES AND SOUND RATED
ASSEMBLIES.
LEVEL 2 TILE SUBSTRATE: EMBED TAPE AND APPLY SEPARATE FIRST COAT OF
JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES.
LEVEL 3 WALLCOVERINGS AND TEXTURED FINISHES: EMBED TAPE AND APPLY
SEPARATE FIRST AND FILL COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND
TRIM FLANGES.
LEVEL 4 EXPOSED, PAINTED GYPSUM BOARD: EMBED TAPE AND APPLY SEPARATE
FIRST, FILL, AND FINISH COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM
FLANGES WHERE FLAT PAINTS ARE INDICATED.
LEVEL 5 EXPOSED, PAINTED GYPSUM BOARD: EMBED TAPE AND APPLY SEPARATE
FIRST, FILL, AND FINISH COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM
FLANGES, AND APPLY SKIM COAT OF JOINT COMPOUND OVER ENTIRE SURFACE,
WHERE EGGSHELL, SEMI GLOSS AND GLOSS PAINTS ARE INDICATED.
3. SEE SHEETS A3.1, A3.2 & A3.3 FOR INTERIOR ELEVATIONS.
4. SEE SHEET A1.6 FOR CEILING FINISH AND CEILING HEIGHTS.
5. SEE MILLWORK VENDOR FOR CABINET LAMINATE FINISH
6. SEE SHEET A1.10 FOR FLOOR FINISH
A
A
B
B
1 1
2 2
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
(TO FACE OF SIP)
113' 0"
(T
O
F
A
C
E
O
F
S
I
P
)
46
'
0
"
(TO FACE OF SIP)
113' 0"
WALK IN
FREEZER
106
STORAGE
ROOM
103 COLD VAULT
105
WALK IN
COOLER
104
BACK ROOM
109
SALES FLOOR
107
MEN'S
RESTROOM
102
HALLWAY
111
PREP AREA
110
CASHIER
108
EXTERIOR ROOF
ACCESS LADDER
FRP2
TR 02
TR 03
TR 01
FRP3
TR 03
P1
B1
WB4
WB1
WB1
B2
FRP1
B1
WB1
B2 B2
P1
B1
P1
B1
WB1
DC1
WB1
FRP2 TR 03WB4
P4
WB1
TR 03
FRP2
DC1
WB1
TR 03
FRP2
B1
WB1
FRP1
B1
WB1
FRP1
FRP2
TR 02
WB4
FRP2
TR 02
WB4
FRP2
TR 02
TR 03
WB4
P1
FRP3 TR 03 WB4
WB4
P2 SOFFIT
P3
SOFFIT CO2
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
WB3
WB4
P2
SOFFIT
FRP4 FRP4
FRP4
TR 03FRP4
TR 03
TR 01
P1
TR 01
P1
TR 01
P1 TR 01
P1
TR 01
P1
WOMEN'S
RESTROOM
101
FRP2
TR 02
WB4 FRP4
P1
TR 01
TR 03
FRP2
TR 02
WB4FRP4
P1
TR 01
TR 03
VE
E
D
E
R
RO
O
T
P1
FRP2
TR 03
WB2
WB4
COOLER WALL
STUD WALL ABOVE COOLER
WB3
WB2
WB4
COOLER WALL
STUD WALL ABOVE COOLER
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A1.11
PROJECT NUMBER: 24212
WALL FINISH PLAN
AND FINISH SCHEDULE
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
GENERAL NOTES
T1 DalTile 24"x24" Porcelain Slate Attache' Multi Brown Concrete Slab CK Floor Tile. Grout: G1, 3/16" Grout Line.
Tile
P7 RAL Powdercoat Gloss Silver Cloud Metal Cabinets N/A Provide on all cabinetry by manufacturer
P6 RAL Powdercoat Gloss Black Metal Cabinets N/A Provide on some cabinetry & gondola by Manufacturer
P5 Sherwin WIlliams Paint Semi Gloss SW7017 Dorian Gray Doors & Frames GC All interior doors and frames
P4 Sherwin WIlliams Paint Eggshell SW6965 Hyper Blue WB1 GC Walls behind the fountain and Cold Beverage
P3 Sherwin WIlliams Paint Eggshell SW6887 Navel WB1 GC CK Orange Walls and Soffits
P2 Sherwin WIlliams Paint Flat SW7006 Extra White CB1 GC Hard Deck Ceilings
P1 Sherwin WIlliams Paint Eggshell SW7006 Extra White WB1,WB2,WB3 GC Most Walls
Paints
ACT4 Varies 2'x2' Fine Fissured White Suspended GC 15/16" Suspension system with 2'x2' T Bar grid Prefinished White
ACT3 Varies 2'x2' Vinyl Clad Sheetrock P3 Suspended GC 15/16" Suspension system with 2'x2' T Bar grid P3
ACT1 Varies 2'x2' Vinyl Clad Sheetrock White Suspended GC 15/16" Suspension system with 2'x2' T Bar grid Prefinished White
Suspended Ceilings
PLY1 Varies 5/8" Plywood GC
WB4 Varies 5/8" CWB/SIP OSB LEVEL 2 See General Notes N/A Cooler Box/Rest GC 5/8" Cement wall board/SIP OSB Level 2 finish to accept tile. All other wall tile applications.
WB3 Varies 1/2" CWB LEVEL 2 See General Notes N/A Cooler Box GC 1/4" Cement wall board Level 2 finish to accept tile. For Use on Cooler Walls.
WB2 Varies 1/4" GWB LEVEL 3 See General Notes N/A To SIP GC 1/4" Gypsum Wall Board Level 3 Finish
WB1 Varies 5/8" GWB LEVEL 3 See General Notes N/A To SIP/OSB GC 5/8" Gypsum Wall Board Level 3 Finish
CB1 Varies 5/8" GCB LEVEL 4 See General Notes N/A To Studs GC 5/8" Gypsum Ceiling Board Level 4 Finish
Substrates
B3 DalTile Coved Tile Base 6X12 Tile Portfolio PF10 Cotto WB3 CK P36C9T. Use Cove Base inside and outside corners as needed. Grout: G1
B2 Everidge 4" Coved Metal Silver Embossed Cooler Box CK By Cooler/Freezer Vendor
B1 Varies 4" Rubber Base N/A Black WB1, WB2 GC 4" High rubber base, use inside and outside corners as needed
Base
Key / Category Manufactuer Type Finish Color Substrate Provided By Description/Remarks
INTERIOR FINISH MATERIALS
SS 1 Wilsonart Solid Surface N/A Arctic Melange 9070ML Countertops CK Provide on all Cabinetry by Manufacturer
PLAM1 Wilsonart Laminate 38 Finish Natural Rift 7954 38 Cabinetry N/A Provide on all Cabinetry by Manufacturer
DC5 Décor Company Décor PVC Panel Blue Prism PREFAB CK Décor Panels By Décor Company
DC4 Décor Company Décor PVC Panel Red Ribbed WB1 CK Décor Panels By Décor Company
DC3 Décor Company Décor PVC Panel Orange Ribbed WB1 CK Décor Panels By Décor Company
DC2 Décor Company Décor PVC Panel Blue Ribbed WB1 CK Décor Panels By Décor Company
DC1 Décor Company Décor PVC Panel Red Sunrise WB1 CK Décor Panels By Décor Company
FRP4 Marlite Symmetrix FRP Digital Tile Print 12"x24" Multi Brown WB4 CK Blue Sky Advance Finish, Marlite Aluminium Trim Molding
FRP3 Marlite Symmetrix FRP Digital Tile Print Subway Orange WB3, WB4 CK Sani Coat FRP, marlite Aluminium Trim Molding
FRP2 Marlite Symmetrix FRP Digital Tile Print Subway White WB3, WB4 CK Sani Coat FRP, marlite Aluminium Trim Molding
FRP1 Marlite FRP Pebbled P 100 White or Equal PLY1 GC All Back Rooms Use all standard trim for panels.
CS1 WR Meadows Concrete Sealer VoComp A20 Clear Concrete Slab GC Scrub & Seal Floors that are exposed concrete. Apply per mfg recommendation
PREFAB Everidge Cooler Panel Aluminum Silver Embossed N/A CK Prefabricated insulated cooler box panels by manufacturer
Misc.
TR09 Varies 2X2 Outside Corner A560 Stainless Steel WB1 GC 2"X2" Outside Stainless Steel Corner Guards
TR08 Schluter Reno Ramp AERP100B65 Satin Anodized Alum T1 GC Tile Installer to provide and install ramp for transition from Tile to Concrete
TR07 Marlite Connectors Varies Satin Anodized Alum TR01, TR02, TR03 GC Any Connectors needed for Schluter to be provided by Installer
TR06 Marlite Quadec In/Cnr A551 Satin Anodized Alum TR 02 CK Inside/Outside Corners to be used with inside corner trim
TR03 Marlite EDGE A570 Satin Anodized Alum FRP2, FRP3 CK To be used where any floor tile meets wall tile.
TR02 Marlite DIVSION A565 Satin Anodized Alum FRP4. FRP2 CK To be used to separate transition between T4 & T2; restrooms only.
TR01 Marlite EDGE A570 Satin Anodized Alum FRP2, FRP3 CK To be used on all outside corner, and to cap/terminate Subway tile.
Trims
G1 Mapei Ultracolor Plus FA 3/16" Grout Line #10 Black T1 CK For Use with All Slate Attache' Tile
Grouts
Key / Category Manufactuer Type Finish Color Substrate Provided By Description/Remarks
INTERIOR FINISH MATERIALS
3/16" = 1' 0"
1WALL FINISH PLAN
FINISH FLOOR
+0"
A B3
A4.0
______4
A4.0
______
+8"+18"
+18"0"+18"
+18" +8"
0"0"
+36"
E.
J
.
E.
J
.
+10"+2" +2" +2" +2" +10"
E.
J
.
E.
J
.
12
A8.2
______1
6
STARTER
PANEL
1 STARTER
PANEL
12
STARTER TRACK AT
3" TYPICAL
T.O. WAINSCOT CAP+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
B A H J A B BAHH
B C C CB FGG
JIE
C
D
B C
H
F F B B
E 8 E 7 E 17
E 11E 11 E 8 E 30
E 14
E 8E 3 E 5
TYP.
E 15
TYP.
E 24 E 22E 3
TYP.
E 16E 34 E 8E 8 E 30E 5E 8 E 35 E 35
E 8 E 2
E 30 E 7 E 2
E 17
E 8
TYP.
E 15
TYP.
E 16 E 3
TYP.
E 24
TYP.
E 16 E 8 E 25
TYP.
E 24
T.O. TOWER
+23' 0"
3
A8.1
______
3
A8.1
______
3
A8.1
______
9
A8.1
______
8
A8.1
______8
A8.1
______
9
A8.1
______6
A8.1
______
6
A8.2
______
3
A8.3
______
1
A6.1
______
4
A6.1
______
3
A6.1
______
2
A6.1
______
E 8 E 8E 8 E 11 E 8E 8E 8
E 4 E 4 E 4
E 7
E 37
E 37 E 37
E 15 G E 19 E 15 G
FINISH FLOOR
+0"
AB
3
A4.0
______4
A4.0
______
+8"0"0"+8" 0"+8" 0"+8"
3
A8.1
______
3
A8.3
______3
A8.1
______
5
A9.3
______8
A8.1
______8
A8.1
______
9
A8.1
______
GF
AH
FG
TYP.
0"
TYP.
6
A9.3
______
H
B B
A
HBB
+10" +2" +2" +10"+2"+8"+2"+2"+2"
STARTER TRACK AT
3" TYPICAL +8"
E.
J
.
E.
J
.
12
A8.3
______9
A8.3
______
4
A9.3
______
1
A9.3
______1
A9.3
______
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
B.O. LIGHT FIXTURE
+14' 6"
A
H
E.
J
.
A
H
A
H
AHH
G FG GF
5
A8.1
______5
A8.1
______
5
A8.1
______
E 13
E 13
TYP.
E 24
E 18
E 8
E 8
E 11
E 10
E 11 E 11E 11
E 7 E 29 E 9E 30
E 8 E 9 E 30
E 9 E 30E 8 E 8
E 8
E 7
E 8E 7E 7
E 8 E 8 E 7
E 15 E 16 E 16 E 15
TYP.
E 24E 15 E 16 E 15
TYP.
E 24E 16
T.O. TOWER
+23' 0"E 36 H E 36 H
E 15
E 37
FINISH FLOOR
+0"
1 2
1
A4.0
______
+8" 0"
+8"0" 96"
362"
+10"
3
A8.1
______
6
A9.3
______
5
A9.3
______
3
A8.3
______
8
A8.1
______
9
A8.1
______
B
AH
B H
A BGFAA
+2"+10"
A
0"
H
TYP.
STARTER TRACK AT
3" TYPICAL
ALIGN THE NICHIHA PANEL
WITH THE DOOR OPENING
2"
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
T.O. PARAPET
+18' 6"
B.O. LIGHT FIXTURE
+14' 6"
EQ EQ
A G
EQ EQ
E 8
E 31 E 8
E 33E 9
TYP.
E 24E 8E 10E 25
E 11E 11E 12 E 9
E 8
E 15 E 26
E 7
E 7 E 8
E 8 E 37
E 16 E 15
TYP.
E 24
T.O. TOWER
+23' 0"
E 29E 6 E 23
E 37 H
FINISH FLOOR
+0"
12
1
A4.0
______
+8"0" 0"+8"
96"
468"
3
A8.3
______
9
A8.1
______
8
A8.1
______
6
A9.3
______
5
A9.3
______
+10"+2" +2"+10"
TYP.
ALIGN THE NICHIHA
PANEL WITH THE
DOOR OPENING
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
T.O. PARAPET
+18' 6"
B.O. LIGHT FIXTURE
+14' 6"
B
H
A HH
A G F A
H
AG
HH
A
EQ EQ EQ EQ
G 5
A9.3
______
6
A9.3
______
E 8
E 31E 8
E 33E 9
TYP.
E 24 E 8
E 11E 11 E 37E 12E 9
E 8
E 15E 26
E 7
E 7E 8E 37
E 16E 15E 42E 43
TYP.
E 24
T.O. TOWER
+23' 0"
E 15
***NICHIHA TUFF BLOCK
COLOR TO MATCH #SW 6095 TOASTY
***NICHIHA TUFF BLOCK
COLOR TO MATCH #SW 6115 TOTALLY TAN
1" INSULATED, DOUBLE PANED GRAY TINTED GLASS
*SHERWIN WILLIAMS #SW 4081
**SAFETY RED
*SHERWIN WILLIAMS #SW 7005
CIRCLE K WHITE
***NICHIHA CHISELED SILL TAN
***NICHIHA LEDGESTONE BLUFF
*SHERWIN WILLIAMS #SW 6090 JAVA
FIRESTONE MANSARD BROWN SR (USE FOR PRE FINISHED METAL FASCIA)
CIRCLE K ORANGE #PMS 144
*** NICHIHA TUFF BLOCK
COLOR TO MATCH #SW 4081
* USE SHERWIN WILLIAMS MANUFACTURER ONLY
** COLOR TO BE PRE ORDERED TO ENSURE AVAILABILITY
AT TIME OF CONSTRUCTION
***TO BE PURCHASED BY CIRCLE K/INSTALLED BY G.C.
G.C. TO COORDINATE WITH CK PM AND OWNER'S REP
circlek@nichiha.com
J
A
B
C
D
E
F
G
H
I
5 FASTENERS PER ULTIMATE CLIP @ 6” O.C.
#8 OR #10 FULLY THREADED WOOD SCREW, 1” LONG
FASTEN STARTER TRACK @ 12” O.C.
#8 OR #10 FULLY THREADED WOOD SCREW, 1” LONG
FACE FASTENERS TO CDX PLYWOOD @ 8” O.C.
#8 OR #10 FULLY THREADED WOOD SCREW, 1 1/2” LONG
FACE FASTENERS BACK TO STUDS @ 16” O.C.
#8 OR #10 FULLY THREADED WOOD SCREW, 3 1/2” LONG, MIN.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A2.1
PROJECT NUMBER: 24212
EXTERIOR ELEVATIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
KEY NOTES
FINISH SCHEDULE
X
X
3/16" = 1' 0"
1FRONT ELEVATION (SOUTH)
3/16" = 1' 0"
2BACK ELEVATION (NORTH)
3/16" = 1' 0"
3SIDE ELEVATION (EAST)
3/16" = 1' 0"
4SIDE ELEVATION (WEST)
NOTE FOR GC: GC TO REVIEW DETAIL 9/ A8.1 &
12/A8.2, STARTER PANEL BEFORE STARTING
TO INSTALL NICHIHA PANEL
NUMBER DESCRIPTION
E 2 LINE OF CANOPY / SOFFIT
E 3 DARK BRONZE ANODIZED WINDOW FRAME W/ GRAY TINTED GLASS PER SOLARBAN
SOLARGRAY SPECS, SEE GLAZING SCHEDULE ON SHEET A6.0
E 4 INTERNALLY ILLUMINATED SIGN (UNDER SEPERATE PERMIT)
E 5 DARK BRONZE ANODIZED DOOR W/ GRAY TINTED GLASS STOREFRONT SYSTEM
E 6 SERVICE DOOR, PAINT TO MATCH SURROUNDING WALL
E 7 PRE FINISHED METAL FASCIA COPING
E 8 NICHIHA FIBER CEMENT WALL PANEL SYSTEM
E 9 WALL MOUNTED LIGHT FIXTURE, COLOR: BRONZE. SEE ELECTRICAL PLAN
E 10 SERVICE DISCONNECT PANEL LOCATION. SEE ELECTRICAL PLAN
E 11 ROOF LINE AND HVAC UNITS
E 12 1 1/2" NICHIHA CORNER KEY EDGE, TYP. TO ALL CORNERS
E 13 DOWNSPOUT, RE: PLUMBING PLAN
E 14 ADDRESSING LOCATION: 8" TALL INCH BLACK NUMBERS. FINAL AREA LOCATION TO
BE DETERMINED BY FIRE DEPARTMENT.
E 15 1 3/8" THK. X 6" NICHIHA KURASTONE HIGH FIBER CEMENT WAINSCOT
E 16 1 1/2" HIGH NICHIHA FIBER CEMENT CAP INSTALL PER MFR. SPECS.
E 17 NICHIHA OVERHANG FLASHING, SEE DETAIL 2/A8.3
E 18 PARAPET WALL BEYOND
E 19 (KNOX) KEY BOX AT 6' 0" AFF (IF REQUIRED BY FIRE DEPARTMENT).
E 22 EMERGENCY FUEL SHUT OFF SWITCH, REFER TO FUEL SHEETS
E 23 INSULATED METAL DOOR
E 24 NICHIHA ESSENTIAL "STARTER" FLASHING 3" FROM THE HARD SURFACE.
E 25 CO2 TANK WITH METAL LOUVERED CONTAINER
E 26 EXTERIOR FINISH TO EXTEND ABOVE SIDEWALK/GRADE, SEE DET. 8/A8.1.
E 29 METAL ROOF ACCESS LADDER WITH SECURITY DOOR LADDER GUARD MODEL # LG6
C1 P2 COTTERMAN
E 30 CONTROL/EXPANSION JOINT "E.J." LOCATION, SEE DETAIL 5/A8.1
E 31 NICHIHA FIBER CEMENT SOFFIT PANEL. SEE DETAILS 1/A8.3 & 2/A8.3.
E 33 WALL MOUNTED EMERGENCY LIGHT FIXTURE, COLOR: BRONZE. SEE ELECTRICAL
PLAN
E 34 DARK BRONZE ANODIZED WINDOW FRAME WITH SPANDREL GLASS.
E 35 DOOR DECAL PROVIDED AND INSTALL BY GRAPHIC VENDOR.
E 36 SCUPPER AND OVER FLOW DRAIN, SEE A1.7 & DETAIL 8/A8.3 & 9/A8.3 FOR SIZE
E 37 PRE FINISHED METAL CORNICE
E 42 EXIT DOOR PAINT TO MATCH SURROUNDING WALL
E 43 INSULATED METAL DOUBLE LEAF DOOR IN HOLLOW METAL FRAME, SEE DOOR
SCHEDULE A6.0
FASTENING SCHEDULE FOR NICHIHA PANEL
FINISH FLOOR
+0"
B.O. CEILING+10' 10"FRP2
10.02
DC1
24"X36" LED SNAP
FRAME SIGNS BY CIRCLE
K DECOR VENDOR4" LETTERS BY
CIRCLE K DECOR
VENDOR
12" COOLERWALL ICONS
QTY 8 BY CIRCLE K DECOR
VENDOR
48" X 18" COOLER ICON
CENTERED OVER COLD VAULT
ENTRY BY CIRCLE K DECOR
VENDOR
FRP2
10
'
1
0
"
TYP.
08.03
B.O. TRUSS
+12' 2"
3'
9
"
4' 1 3/4" 12' 7 5/8" SEE FLOOR PLAN 44' 8 5/8"
5 1/4"
11' 5 1/2" 8' 5"
FRP2
13.04
R008 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007 R007
13.03
B1
TR 03 TR 03P1
DC3
10.02
06.02
16.07
P1
P2
H001 H001 H005 O001 B006
B503
FRP3
TR 03
TR 01
R007 R007 R007R007
P413
P1
FINISH FLOOR
+0"
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
46" X 31" POLAR POP SIGN BY
CIRCLE K DECOR VENDOR
46" X 31" FROSTER SIGN BY
CIRCLE K DECOR VENDOR
24"x 36" LED SNAP
FRAME BY CIRCLE K
VENDOR VOMELA
DC2
10.02
FRP2
30' 8 1/4" 4' 10 1/2"
NOTE: GC TO COORDINATE WITH CK CM
FOR THE CABINETS BELOW COUNTER
B301B405 B301 B405 B406 B403 B001 B001
B101
B001 B404
B102
6'
9
"
4
'
1
"
P4
06.02
3'
9
"
M011
B.O. TRUSS
+12' 2"
B.O. SOFFIT
10' 6"
TR 03
10
'
1
0
"
M011B003B003
V101
FINISH FLOOR
+0"
M104
R401M107
LOTTO
MACHINE
LOTTO
STANDTELE
COM
SUNGLASS
& CELL
PHONE
SPINNER
4'
0
"
V201
4" LETTERS BY
CIRCLE K DECOR
VENDOR
13.03
T001T001
13.0313.03
T107
06.02
08.01
DC1
P1 P1 P1
C001
C107 C107
C001C001
P204
M108
T011 T010
B1
DOOR DECAL PROVIDED AND INSTALL
BY GRAPHIC VENDOR
DOOR DECAL PROVIDED AND INSTALL
BY GRAPHIC VENDOR
B.O. TRUSS
+12' 2"
B.O. CEILING
10' 6"
B.O. CEILING
10' 10"
16.06 16.06
B1 B1
24"x36" LED SNAP
FRAMES (2) BY CIRCLE
K DECOR VENDOR
T108
B.O. CEILING
10' 6"
P1
TR 09
TR 09
V004 V004
06.02
O008
O005
C002
C005 C109 C004
C106
8' 1 1/8"13' 10 3/8"29' 2"8' 3 7/8"
P205
FINISH FLOOR
+0"
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
R203
33" x 22" RESTROOM SIGN BY
CIRCLE K DECOR VENDOR
DC410.02
FRP3 BEYOND
P1
P1
P1
M012 R210
DOOR DECAL PROVIDED AND INSTALL
BY GRAPHIC VENDOR
B.O. TRUSS
+12' 2"
B.O. CEILING
10' 10"
B1 B1 TR 03
FRP2
3'
9
"
R008
27' 0" 6' 0"
?
10
'
1
0
"
08.02
FFL
1
1
/
4
"
2'
5
"
2
3
/
4
"
V101
2'
9
"
1
1
/
4
"
2
'
5
"
2
3
/
4
"
4' 11"
M007M006
2'
9
"
1
1
/
4
"
2
'
5
"
2
3
/
4
"
5' 10"
H206 H209 H106 O001 H209
V101
1
1
/
4
"
2
'
4
3
/
4
"
3
3
/
4
"
O001 H303 B006 H103 O001 H107 H104 H108
R207V101
2'
9
3
/
4
"
3
3
/
4
"
2'
4
3
/
4
"
1
1
/
4
"
4' 5" 3' 11" 2' 2"
H109H110H111
FFL
H209 O001 B006
V101
5' 1"
1
1
/
4
"
2'
4
3
/
4
"
3
1
/
2
"
FFL
V101
H104 H108 H206
H208
2'
9
3
/
4
"
5' 1"
3
3
/
4
"
2
'
4
3
/
4
"
1
1
/
4
"
M014 M014
1. SEE SHEET A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT.
2. VERIFY EQUIPMENT LAYOUT WITH CIRCLE K
3. ATM & BITCOIN SHALL COMPLY WITH SECTIONS 220 AND 707 OF THE 2010 ADA STANDARDS
FOR ACCESSIBLE DESIGN
4. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE EXPOSED PORTIONS OF
DINING SURFACES AND WORK SURFACES. ICC A117.1 2009 CHAPTER 9, SEC 902.3
5. SEE SHEET A1.11 FOR INTERIOR FINISHES
*
*
M014
H103O001
H111
H110H109
R207
H104
H107
H108
H206 H209 H209
O001
H106
O001
B006
H207
M007
M006
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A3.1
PROJECT NUMBER: 24212
INTERIOR ELEVATIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
GENERAL NOTES
KEYNOTES
NUMBER DESCRIPTION
06.02 CUSTOM CASEWORK SUPPLIED BY CIRCLE K, INSTALLED BY CIRCLE K VENDOR.
08.01 ALUMINUM STOREFRONT SYSTEM, SEE SHEET A6.0.
08.02 INSULATED METAL DOOR IN HOLLOW METAL FRAME.
08.03 HOLLOW METAL DOOR IN HOLLOW METAL FRAME. SEE DOOR SCHEDULE ON SHEET
A6.0
10.02 GRAPHICS SUPPLIED AND INSTALLED BY CIRCLE K DECOR VENDOR NO WALL
PENETRATIONS IN GRAPHIC AREAS.
13.03 COOLER REACH IN DOOR BY MANUFACTURER.
13.04 COLD VAULT DOOR BY MANUFACTURER.
16.06 LED LIGHTING BY VENDOR.
16.07 WALL MOUNTED BLUE LED LIGHTING. SEE ELECTRICAL.
1/4" = 1' 0"
1AREAR WALL ELEVATION (COLD VAULT/COOLER WALL/BACK ROOM)
1/4" = 1' 0"
1BRIGHT WALL (FOOD AREA/FOUNTAIN WALL)
1/4" = 1' 0"
1CFRONT WALL (COFFEE WALL/ENTRY/CASHIER/ENTRY/SEATING AREA)
1/4" = 1' 0"
1DLEFT WALL (REACH IN FREEZER WALL/HALLWAY/BEER CAVE)
COFFEE CONDIMENTS ISLAND HOT FOOD + ROLLER GRILL ISLAND BEER TROUGH
1. INTERIOR ELEVATIONS AT SALES FLOOR (107)
PLAN
LEFT SIDE FRONT / REAR TYP.RIGHT SIDE RIGHT
LEFT PLAN
FRONT REAR
FFL
30" X 54" BEER TROUGH
PLAN
RIGHT SIDE SIDE
2.CABINET ELEVATIONS AT SALES FLOOR (107)
XX.XX
FINISH FLOOR
+0"
FRP1
A9.2
4
B1
FRP1
08.03
V201
FRP1
4'
0
"
B1TR 09
B.O. LOFT
7' 6"
B.O. CEILING
10' 8"
TR 09
FINISH FLOOR
+0"
P401
FRP1
A9.2
4
DRE 52 18
FRP1 FRP1
V201
B603 B603 B603 B603 B603 S003 S003 S003
4' 10" 4' 8" 14' 0" 6' 0"
16" X 16" ACCESS PANEL, GC TO COORDINATE
LOCATION AS NEEDED FOR EQUIPMENT INSTALLATION
B1 TR 09
P402
B1 B1 TR 09 B1TR 09
FRP1
4'
0
"
B.O. LOFT
7' 6"
B.O. CEILING
10' 8"
40
"
M
A
X
.
VEEDER
ROOT
1'
0
"
7
'
0
"
B503
B503
FINISH FLOOR
+0"
P001
P203
P401
A9.2
1
P002
MOP
BUCKET
FRP1
S101 S101
B1
B.O. LOFT
7' 6"
B.O. CEILING
10' 8"
O005
P414
FINISH FLOOR
+0"
T201 V005 O004
V006
B1B1 B1
08.02 V001 V001 V001 V001
S003 S003 S003 S003 S003
GC TO VERIFY SHOP
DRAWING FOR STUB UP
FRP1 FRP1
B.O. LOFT
7' 6"
B.O. CEILING
10' 8"
FINISH FLOOR
+0"
S007
FRP1
A9.2
4
S007
B.O. LOFT
7' 2"
B1
B.O. CEILING
10' 8"
FINISH FLOOR
+0"
A9.2
4
B1
S007 S007
B.O. LOFT
7' 2"
B.O. CEILING
10' 8"
FRP1
FINISH FLOOR
+0"
A9.2
4
S007S007
B.O. LOFT
7' 2"
FRP1
B1
B.O. CEILING
10' 8"
FINISH FLOOR
+0"
A9.2
4
08.03
FRP1
B1
B.O. LOFT
7' 2"
B.O. CEILING
10' 8"
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
T011T010
B.O. CEILING
10' 6"
T011T010
2'
1
0
"
T109
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
H202
H203
H201
64"
TALL
CIG
RACK
64"
TALL
CIG
RACK
64"
TALL
CIG
RACK
64"
TALL
CIG
RACK
64"
TALL
CIG
RACK
B.O. CEILING
10' 6"
06.02
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
64"
TALL
CIG
RACK
T001
08.01
T107
P1
B1
B.O. CEILING
10' 6"
T108 T104
06.02
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
UNDER
COUNTER
SAFE
T101T105 T007 T011 T010
B.O. CEILING
10' 6"
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
H211
H205
R202
H401
LOCKABLE
CARTON
STORAGE FLEX
SPACE
06.02
B.O. CEILING
10' 6"
B.O. CEILING
+10' 10"
H203
H202H201
R202
H205 H211 R206 P204
O005
O008
FINISH FLOOR
+0"
B.O. CEILING+10' 10"
H202
H201
H203
H401
LOCKABLE
CARTON
STORAGE
P1
B1
R206
08.01
B.O. CEILING
10' 6"
B.O. CEILING
+10' 10"
LOCKABLE
CARTON
STORAGE
LOCKABLE
CARTON
STORAGE
LOCKABLE
CARTON
STORAGE
LOCKABLE
CARTON
STORAGE
COATS
06.02
1. SEE SHEET A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT.
2. VERIFY EQUIPMENT LAYOUT WITH CIRCLE K
3. SEE SHEET A1.2 FOR INTERIOR FINISHES
*
*
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A3.2
PROJECT NUMBER: 24212
INTERIOR ELEVATIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
GENERAL NOTES
KEYNOTES
NUMBER DESCRIPTION
06.02 CUSTOM CASEWORK SUPPLIED BY CIRCLE K, INSTALLED BY CIRCLE K VENDOR.
08.01 ALUMINUM STOREFRONT SYSTEM, SEE SHEET A6.0.
08.02 INSULATED METAL DOOR IN HOLLOW METAL FRAME.
08.03 HOLLOW METAL DOOR IN HOLLOW METAL FRAME. SEE DOOR SCHEDULE ON SHEET
A6.0
1/4" = 1' 0"
1CFRONT ELEVATION
1/4" = 1' 0"
1DLEFT ELEVATION (FOUNTAIN WALL)
1/4" = 1' 0"
1AREAR ELEVATION
1/4" = 1' 0"
1BRIGHT ELEVATION
1/4" = 1' 0"
2DLEFT ELEVATION
1/4" = 1' 0"
2AREAR ELEVATION
1/4" = 1' 0"
2BRIGHT ELEVATION
1/4" = 1' 0"
2CFRONT ELEVATION
1/4" = 1' 0"
3AREAR ELEVATION
1/4" = 1' 0"
3BRIGHT ELEVATION
1/4" = 1' 0"
3CFRONT ELEVATION
1/4" = 1' 0"
3DLEFT ELEVATION
1/4" = 1' 0"
4AREAR ELEVATION
1/4" = 1' 0"
4BRIGHT ELEVATION
1/4" = 1' 0"
4CFRONT ELEVATION
1/4" = 1' 0"
4DLEFT ELEVATION
F.R.P. ON GYP. + SIP +
PLYWOOD WALL PANEL
SEE SHEET A1.2
F.R.P. ON PLYWOOD
SEE SHEET A1.2
F.R.P. ON PLYWOOD
SEE SHEET A1.2
3. INTERIOR ELEVATIONS AT CASHIER (108)4. INTERIOR ELEVATIONS AT PREP AREA (110)
2. INTERIOR ELEVATIONS AT STORAGE ROOM (103)
1. INTERIOR ELEVATIONS AT BACK ROOM (109)
F.R.P. OVER GYP. + SIP +
PLYWOOD WALL PANEL.
SEE SHEET A1.2
XX.XX
9' - 0"
CEILING HT.
0' - 0"
FIN. FLOOR
SALES AND SERVICE
COUNTERS ADAAG 904.4
NOTE:
ADAAG GENERALLY SPECIFIES ACCESSIBLE
COUNTER HEIGHTS UP TO 34" (902.3)
MISC. FIXTURES
3' 0"
FULL HEIGHT COUNTER
30
"
.
2
4
"
M
A
X
.
34
"
M
A
X
.
24" MAX.30".
COAT
HOOK
48
"
M
A
X
.
40
"
M
A
X
.
TRASH
1'
7
"
.
2' 2".
SEAT COVER
DISPENSER
12".
3'
3
"
.
SANITARY
NAPKIN
DISPOSAL
SANITARY
NAPKIN /
TAMPON
DISPENSER
T.P. HOLDER
1'
9
"
.
2' 0"
THERMOSTAT
LIGHTS
OUTLETS
15
"
.
BABY CHANGING TABLE
1' 7"
33
"
M
I
N
.
MA
X
T
O
H
A
N
D
L
E
4'
0
"
33
"
3
6
"
BABY CHANGING TABLE
OPTIONAL STRAP
HANDLE IF REQUIRED
39
"
4
1
"
1
1
/
2
"
M
I
N
.
MI
N
.
12
'
.
18
"
M
I
N
.
54" MIN.
7" 9" MAX.
48
"
M
A
X
.
15
"
M
I
N
.
TOILET
PAPER
DISPENSER
42" MIN.12" MAX.
4" MAX. DEEP
CONVENIENCE SHELF
WITH ROUNDED EDGE
TOILET ELEVATION SIDE
39" 41"
TOILET ELEVATION FRONT
* FOR ACCESSIBLE
STALLS ONLY
33
"
3
6
"
16" 18"
17
"
1
9
"
24" MIN.
MIN.
12".
36" MIN.
℄
TOILET PARTITION
OR FINISHED FACE
OF WALL
FLUSH VALVE
17
"
M
A
X
.
48
"
M
A
X
.
URINAL ELEVATIONDRINKING FOUNTAINSLAVATORY CLEARANCES
17" 19"
36
"
M
A
X
.
34
"
.
27
"
H
O
L
D
9"
M
A
X
.
6" MAX.8" MIN.
INSULATED
PIPES
MIRROR
PROVIDE CODE
COMPLIANT HAND
CONTROLS
SU
R
F
A
C
E
40
"
M
A
X
.
TO
R
E
F
L
E
C
T
I
V
E
34
"
M
A
X
.
29
"
M
I
N
.
27
"
M
I
N
.
18
"
M
I
N
.
CLEARANCE
8" MAX. KNEE
CLEARANCE
6" MAX. TOE
17" MIN.SIDEFRONT
20
"
.
HAND
DRYER
3'
2
"
ROYSTON SOLID
SURFACE GUARD
40
"
M
A
X
.
TOWEL
DISPENSER
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
P101
FRP2
TR 03
TR 02
P304
P302
P302
P305
O007
P1
TR 01
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"CONVENIENCE
SHELF
06.03
O008
P101
A9.1
10
PARTITION
WALL
FRP3
P1
P301 P301
P304
O007
P304
O007
P304
O007
O008P1
FRP2
P305 P305
P302
P305
P305
TR 01 TR 01
TR 02
FRP4
TR 03
FRP2
TR 03 P101 P101 P101
P105 P106P106
P1
P1
24" MIN.
3' 0"
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
P1
FRP3 FRP3
O008
P301
P311
TR 03 TR 03
TR 01
54
"
P1
P106
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
1'
8
"
1'
0
"
PARTITION WALL
FRP4 P307
FRP4
FRP2 FRP2TR 02
TR 01
TR 02
TR 03
4'
6
"
P1
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
P101
P302
P305
TR 03
TR 02
FRP4
FRP2
TR 01
54
"
O007
P1
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
PARTITION WALL
1'
8
"
TR 01
FRP2TR 02
TR 03
P1
FRP2 TR 02
TR 03
P307
1'
0
"
FRP4FRP4
TR 01
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
FRP3
P1
P301
O008
P311
FRP3
TR 01
54
"
TR 03
P106
P1
P307
TR 01
B.O. CEILING
+9' 0"
PARTITION WALL
CONVENIENCE
SHELF
FRP3
FRP2
06.03
P301
P101
A9.1
10
P301
O008 O008
FIN. FLOOR
0' 0"O007
FRP2
FRP4
TR 01
TR 02
TR 01
P103 P103
P106 P106
P305
TR 03TR 03
54
"
P305
24" MIN.
3' 0"
P302
P105
P1P1P1
O007
FRP4
A3.33D
3C
3B
3A
A3.3
4C
4D
4A
4B
MEN'S
RESTROOM
102
HALLWAY
111
A3.3
2A
2C
2D
BC
S
BC
S
TRASH CAN TRASH CAN
WOMEN'S
RESTROOM
101
A3.3
8
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
VERTICAL
RUNNING
BOND
FRP PANEL
STARTING
POINT
NOTE:
THIS IS A GENERIC WALL ELEVATION FOR PATTERN AND
STARTING POINT ONLY.
FRP
PANEL
SCHLUTER
QUADEC
FRP
PANEL
COVE
SCHLUTER
FRP4
FRP2
P1
TR 01
TR 02
TR 03
WALL
PAINT
12
"
2'
6
"
2
'
0
"
4
'
6
"
FINISH FLOOR
+0"
P1
B.O. CEILING
+10' 10"
OPENING TO
RESTROOM
VESTIBULE
FRP3
P1
FRP3
TR 01 TR 01
TR 03 TR 03
54
"
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
B.O. CEILING
+10' 10"
8'
6
"
(HALLWAY)(RESTROOM
VESTIBULE)
08.02
P1
TR 02
FRP3
FRP4
TR 01
TR 03
P1
TR 03
FRP2
FINISH FLOOR
+0"
B.O. CEILING
+10' 10"
08.03
FRP3
P1
27
"
M
I
N
.
SP
O
U
T
@
H
.
C
.
36
"
M
A
X
.
T
.
O
.
SP
O
U
T
@
S
T
A
N
D
I
N
G
38
"
M
I
N
.
T
.
O
.
TR 01
TR 02
TR 01
P1
FRP3
54
"
TR 03 TR 03
P413
1. SEE SHEET A1.4, A1.5.1, A1.5.2 & A1.5.3 FOR EQUIPMENT SCHEDULE.
2. CLEAR ACCESS A MIN. OF 44" IN WIDTH THROUGHOUT SANITARY FACILITY TO REACH THE
HANDICAPPED COMPARTMENT. (48" CLEAR @ HINGE SIDE APPROACH TO COMPARTMENT).
3. A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" DIA.. CIRCLE WITHIN THE SANITARY FACILITY
ROOM AT A HEIGHT OF 27" A.F.F. DOORS OTHER THAN THE TOILET COMPARTMENT DOOR MAY NOT
ENCROACH MORE THAN 12".
4. SEE SHEET A1.11 FOR INTERIOR FINISHES
INTERIOR COMPARTMENT:
1. FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA.
2. MAXIMUM HEIGHT FROM FLOOR TO FLUSH VALVE TO COMPLY SECTION 308 (ICC/ANSI 117.1).
3. 5 lb. MAXIMUM FORCE TO OPERATE VALVE.
4. SEE TOILET ACCESSORY MOUNTING HEIGHTS DETAIL FOR HEIGHTS OF GRAB BARS AND
ACCESSORIES.
5. VERTICAL GRAB BARS REQUIRED AT ALL ACCESSIBLE TOILETS.
6. PROVIDE 30X48 ADA ACCESSIBLE SPACE AT LAV.
7. INSULATE WATER AND DRAIN PIPES
8. INSTALL BACKING FOR CHANGING TABLE
9. CHANGING TABLE TO BE INSTALLED BY G.C.
10.PROVIDE SOLID BLOCKING AT WALL FOR SHELVING
*
*
XX.XX
WALL
PAINT
FRP
PANEL
VERTICAL
RUNNING
BOND
COVE
SCHLUTER
P1
FRP3
TILE PATTERN
STARTING POINT
TR 01
TR 03
4'
6
"
SCHLUTER
RONDEC
WALL
PAINT
COVE
SCHLUTER
P1
FRP3
TR 03
FRP PANEL
VERTICAL
RUNNING
BOND
SCHLUTER
RONDEC
3 5/8" 20ga.
METAL TRACK
3 5/8" 20ga.
METAL STUDS
@ 16" O.C.
5' 0"x3' 0"
HOLLOW
METAL DOOR,
IN 7' 0"x3' 0"
METAL FRAME
OPEN
OPEN
OPEN
OPEN
7C
A9.1
______10
A9.1
______
7
A9.1
______
7A
A9.1
______
6"
3' 0"
7'
0
"
4"
1'
8
"
1'
0
"
7B
A9.1
______
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
P308 P308
P307 P307
FRP3
P1
TR 01
FRP2 TR 01
TR 02
FRP4
OPEN
OPEN
OPEN
OPEN
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A3.3
PROJECT NUMBER: 24212
INTERIOR ELEVATIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1/4" = 1' 0"
1FIXTURE MOUNTING DETAILS
1/4" = 1' 0"
4CWOMEN'S RESTROOM FRONT ELEVATION
1/4" = 1' 0"
4DWOMEN'S RESTROOM LEFT ELEVATION
1/4" = 1' 0"
4AWOMEN'S RESTROOM REAR ELEVATION
1/4" = 1' 0"
4BWOMEN'S RESTROOM RIGHT ELEVATION
1/4" = 1' 0"
3CMEN'S RESTROOM FRONT ELEVATION
1/4" = 1' 0"
3DMEN'S RESTROOM LEFT ELEVATION
1/4" = 1' 0"
3AMEN'S RESTROOM REAR ELEVATION
1/4" = 1' 0"
3BMEN'S RESTROOM RIGHT ELEVATION
3/16" = 1' 0"
7RESTROOM KEY PLAN
1/4" = 1' 0"
5TYP. RESTROOM WALL PATTERN
GENERAL NOTES
KEYNOTES
NUMBER DESCRIPTION
06.03 CUSTOM LAVATORY COUNTERTOP SUPPLIED BY CIRCLE K, INSTALLED BY OTHERS
08.02 INSULATED METAL DOOR IN HOLLOW METAL FRAME.
08.03 HOLLOW METAL DOOR IN HOLLOW METAL FRAME. SEE DOOR SCHEDULE ON SHEET
A6.0
1/4" = 1' 0"
2CHALLWAY (111) FRONT ELEVATION
1/4" = 1' 0"
2DHALLWAY (111) LEFT ELEVATION
1/4" = 1' 0"
2AHALLWAY (111) REAR ELEVATION
1/4" = 1' 0"
6RESTROOM PARTITION WALL FRAMING
2. ELEVATIONS AT HALLWAY 1 (111)
3. ELEVATIONS AT MEN'S RESTROOM (102)
4. ELEVATIONS AT WOMEN'S RESTROOM (101)NOTE:
G.C. TO PROVIDE SCHLUTER
"RONDEC" TRIM (TR 01) ON ALL
INSIDE / OUTSIDE TILE CORNERS
1/4" = 1' 0"
8RESTROOM ENTRY ELEVATION
FINISH FLOOR
+0"
FINISH FLOOR
+0"
A B
B.O. CEILING
+9' 0"
B.O. CEILING
+10' 10"
BACK ROOM
109
SALES FLOOR
107
MEN'S
RESTROOM
102
A9.2
4SALES FLOOR
107
A5.1
2A5.1
3
T.O. WAINSCOT CAP
+3' 1 3/4"
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
B.O. TRUSS
+12' 2"
T.O. TOWER
+21' 6"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
T.O. PARAPET
+18' 6"
K 10
K 01K 01
K 03
K 06
K 09
K 08 K 08K 13K 14K 04 K 02
K 06
K 03 K 04 K 14 K 08K 08
WOMEN'S
RESTROOM
101
(BEYOND)
R008
3'
9
"
K 16
K 16
FINISH FLOOR
+0"
FINISH FLOOR
+0"
1 2
B.O. CEILING
+10' 10"
A5.2
2
WALK IN
COOLER
104
SALES FLOOR
107
A9.2
5
HALLWAY
111T.O. WAINSCOT CAP
+3' 1 3/4"
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
K 01
K 04 K 05
K 07K 07
K 08
K 06
K 01
K 03 K 04K 02
B.O. CEILING
10' 6"
T.O. TOWER
+23' 0"
K 16K 16
FINISH FLOOR
+0"
FINISH FLOOR
+0"
1 2
B.O. CEILING
+10' 10"
A5.2
3
COLD VAULT
105
SALES
FLOOR
107
HALLWAY
111
T.O. WAINSCOT CAP
+3' 1 3/4"
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
T.O. PARAPET
+18' 6"
K 01
K 08 K 02K 03 K 04 K 08
K 06
K 16K 16
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A4.0
PROJECT NUMBER: 24212
BUILDING SECTIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
KEYNOTES
3/16" = 1' 0"
1BUILDING SECTION
3/16" = 1' 0"
3BUILDING SECTION
3/16" = 1' 0"
4BUILDING SECTION
NUMBER DESCRIPTION
K 01
CONCRETE SLAB WITH MINIMUM 15ML VAPOR BARRIER LAPPED A
MINIMUM OF 6" & TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE
STRUCTURAL. CONCRETE SLAB, SEE STRUCTURAL FOR REINFORCING.
K 02 ROOF JOIST
K 03 TPO ROOFING SYSTEM OVER SIP ROOF PANEL. WALKWAYS AS REQUIRED BY
ROOFING MANUFACTURE.
K 04 PARAPET BEYOND
K 05 ROOF TOP HVAC UNIT, SEE MECHANICAL DRAWINGS.
K 06 SIP WALL PANEL.SEE SIP SHEETS.
K 07 WALK IN FREEZER/COOLER WALL.
K 08 ALL DUCT WORK TO GO THROUGH TRUSSES.
K 09 SWITCHGEAR CABINET BEYOND.
K 10 EXTERIOR ROOF ACCESS LADDER WITH SECURITY DOOR.
K 13 DRAFT STOP SEE DETAIL 1/A8.3.
K 14 ROOF DRAIN SCUPPER AND EMERGENCY RELIEF SCUPPER.
K 16 2" RIGID INSULATION BELOW GRADE 24" HORIZONTAL AND VERTICAL
FINISH FLOOR
+0"
B
BACK ROOM
109
A8.1
8
A8.1
9
A8.3
3
A8.3
10
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
B.O. LIGHT FIXTURE
+14' 6"
J 03
J 01
J 02
J 36J 35
J 20
J 05
J 10
J 19
J 13J 11
J 30
J 30
J 14
J 23
J 24
J 19
J 40
J 40
FINISH FLOOR
+0"
A
MEN'S
RESTROOM
102
A8.3
3
A8.3
10
A8.1
8
A8.1
9
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
J 11
J 09
J 05
J 23J 23
J 13
J 19
J 10
J 19
J 10
J 01
J 03
J 32
J 14
J 30
J 30
J 24
J 18
J 40
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A5.1
PROJECT NUMBER: 24212
WALL SECTIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
SHEET A5.1 AND A5.2 HAVE THE SAME KEY NOTES, APPLICABLE KEY
NOTES ARE NOTED ON WALL SECTION
KEYNOTES
1/2" = 1' 0"
2WALL SECTION
1/2" = 1' 0"
3WALL SECTION
NUMBER DESCRIPTION
J 01 CONCRETE SLAB WITH MINIMUM 15ML VAPOR BARRIER LAPPED A MINIMUM OF 6" &
TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL.
J 02 CONCRETE WALK, BROOM FINISH., SEE SITE PLAN SHEET SD1.1 /CIVIL PLANS
J 03 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION.
J 05 WOOD TRUSSES, SEE SIP DRAWINGS FOR SPECIFIC INFORMATION.
J 09 2X BLOCKING, SEE SIP SHEETS.
J 10
5/8" THK. X 17 7/8"H X 71 9/16"L FIBER CEMENT WALL NICHIHA PANEL SYSTEM PER
MANUFACTURER SPECIFICATIONS OVER FELT WATER RESISTIVE BARRIER. REFER TO
EXTERIOR DETAILS ON SHEETS A8.1, A8.2 & A8.3
J 11 TPO ROOFING SYSTEM OVER SIP ROOF PANEL. WALKWAYS LOCATED PER ROOF PLAN.
SEE ROOF PLAN FOR R 33.
J 13 EXTEND TPO ROOFING TO UNDERSIDE OF METAL FASCIA OVER TOP OF WALL.
J 14 PARAPET/TOWER BEYOND
J 18 GYPSUM BOARD CEILING
J 19 SIP WALL PANEL.SEE SIP SHEETS.
J 20 GRID CEILING, SEE RCP SHEET A1.6 AND DETAILS 10 & 11/A9.2.
J 23 1/2" EXPANSION JOINT MATERIAL.
J 24 PRE FINISHED SNAP ON GALV. METAL FASCIA
J 30 FIBER CEMENT NICHIHA WALL PANEL SYSTEM BEYOND
J 32 METAL STUDS CONSTRUCTION.
J 35 STORAGE SHELF SEE DETAIL 4/A9.2
J 36 LINE OF MAIN SWITCHGEAR BEYOND
J 40 2" THK. BELOW GRADE RIGID INSULATION 24" HORIZONTAL & VERTICAL
FINISH FLOOR
+0"
B.O. CEILING
+9' 0"
1
A8.3
3
B.O. TRUSS+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
J 01
J 18
J 19
J 10
J 19
J 02
J 03
J 23
J 23
J 24
J 13
J 07
J 09
J 19
J 10
1/4" / 1' 0"
1' 6"
J 07
A9.3
1
J 50
J 40
J 40
FINISH FLOOR
+0"
1
B.O. CEILING+10' 10"
A8.1
10
A8.1
6
A8.3
10
A8.3
3
A8.2
12
A8.3
2
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
T.O. TOWER
+21' 6"
T.O. PARAPET
+18' 6"
J 03
J 01
J 04
J 28
J 30
J 29
J 25
J 26
J 39
J 10
J 31
J 09
J 09
J 13J 19
J 10
J 24
J 09
J 34
J 19
J 09
J 25 J 20
J 19
J 23
J 30 SALES
FLOOR
107
1' 6"
1/4" / 1' 0"
J 53
J 40
FINISH FLOOR
+0"
1
B.O. CEILING
+10' 10"
A8.3
10
A8.2
4
A8.2
12
A8.2
3
A8.3
2
T.O. WAINSCOT CAP
+3' 1 3/4"
B.O. TRUSS
+12' 2"
T.O. ROOF PANEL
+17' 4"
J 01
J 03
J 23
J 29
J 30
J 10
J 27J 39 J 25
J 05
J 21
J 19 J 34
J 09
J 10
J 09
J 13
J 14
J 11
J 28
J 20
J 24
J 19
J 26
SALES FLOOR
107
J 10
3' 0"
1/4" / 1' 0"
T.O. TOWER
+23' 0"
J 06
J 40
J 40
A8.1
3
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A5.2
PROJECT NUMBER: 24212
WALL SECTIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1/2" = 1' 0"
1WALL SECTION
1/2" = 1' 0"
3WALL SECTION
1/2" = 1' 0"
2WALL SECTION
SHEET A5.1 AND A5.2 HAVE THE SAME KEY NOTES, APPLICABLE KEY
NOTES ARE NOTED ON WALL SECTION
KEYNOTES
NUMBER DESCRIPTION
J 01 CONCRETE SLAB WITH MINIMUM 15ML VAPOR BARRIER LAPPED A MINIMUM OF 6" &
TAPED PER MANUFACTURER'S SPECIFICATIONS, SEE STRUCTURAL.
J 02 CONCRETE WALK, BROOM FINISH., SEE SITE PLAN SHEET SD1.1 /CIVIL PLANS
J 03 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS FOR SPECIFIC INFORMATION.
J 04 1 3/8" THK FIBER CEMENT KURASTONE NICHIHA WALL SYSTEM PER MANUFACTURER
SPECIFICATIONS. REFER EXTERIOR DETAIL SHEET A8.1
J 05 WOOD TRUSSES, SEE SIP DRAWINGS FOR SPECIFIC INFORMATION.
J 06 2X WOOD STUD @ 16" O.C., SEE SIP DRAWINGS.
J 07 2X DOUBLE TOP PLATE @ 12' 2" A.F.F., SEE SIP SHEETS.
J 09 2X BLOCKING, SEE SIP SHEETS.
J 10
5/8" THK. X 17 7/8"H X 71 9/16"L FIBER CEMENT WALL NICHIHA PANEL SYSTEM PER
MANUFACTURER SPECIFICATIONS OVER FELT WATER RESISTIVE BARRIER. REFER TO
EXTERIOR DETAILS ON SHEETS A8.1, A8.2 & A8.3
J 11 TPO ROOFING SYSTEM OVER SIP ROOF PANEL. WALKWAYS LOCATED PER ROOF PLAN.
SEE ROOF PLAN FOR R 33.
J 13 EXTEND TPO ROOFING TO UNDERSIDE OF METAL FASCIA OVER TOP OF WALL.
J 14 PARAPET/TOWER BEYOND
J 18 GYPSUM BOARD CEILING
J 19 SIP WALL PANEL.SEE SIP SHEETS.
J 20 GRID CEILING, SEE RCP SHEET A1.6 AND DETAILS 10 & 11/A9.2.
J 21 RECESSED SOFFIT LIGHT, SEE ELECT & RCP SHEET.
J 23 1/2" EXPANSION JOINT MATERIAL.
J 24 PRE FINISHED SNAP ON GALV. METAL FASCIA
J 25 I BEAM, SEE STRUCTURAL
J 26 FLY REGLET SOFFIT VENT, SEE DETAIL 2/A8.3
J 27 ATTIC ACCESS HATCH AT SOFFIT AREA, SEE SHEET A1.6 FOR LOCATION AND DETAIL
2/A8.1
J 28 PILASTER BEYOND
J 29 ALUMINUM STOREFRONT SYSTEM
J 30 FIBER CEMENT NICHIHA WALL PANEL SYSTEM BEYOND
J 31
PROVIDE & INSTALL 1/2" GYPSUM BOARD VERTICALLY AT HORIZONTAL INTERVALS OF
MAXIMUM 10' 0" SPACING FOR FIRE BLOCKING OF CONCEALED COMBUSTIBLE SPACES
TO COMPLY WITH IBC SECTION 718.2.2
J 34 5/8" GYPSUM WALL BOARD EXTEND ABOVE CEILING
J 39 NICHIHA WALL SYSTEM PANEL OVER OSB SHEATHING, SEE DETAIL 2/A8.3
J 40 2" THK. BELOW GRADE RIGID INSULATION 24" HORIZONTAL & VERTICAL
J 50 ALL DUCT WORK TO GO THROUGH TRUSSES SEE MECH.
J 53 WATER RESISTIVE BARRIER OVER SIP PANEL.
6
A8.2
______
12
A8.2
______
9
A8.2
______
T
9
A8.2
______
6
A8.2
______
12
A8.2
______
T
4
A8.2
______
T
1
A6.1
______2
A6.1
______
4
A6.1
______
BA
7'
4
"
3
'
1
3
/
4
"
10
'
5
3
/
4
"
16' 10"
2" EQ. 2" EQ. 2" EQ. 2" EQ. 2"
2"
3
'
1
3
/
4
"
2
"
7
'
0
"
2"EQ. 2" EQ. 2" EQ.
2"
15' 10"
B1 B1
B
15' 10"
2"EQ. 2" EQ. 2" EQ.
2"
2" 3' 0" 12' 8"12' 8" 3' 0"
2"
4' 2"2" 2"EQ. 2" EQ.
2"
12' 8"
C 1
4' 4" 8' 4"
B2 S S
C
B2
NOTE: G.C. TO USE 1" INSULATED, DOUBLE
PANED GRAY TINTED GLASS FOR ALL
STOREFRONT WINDOW PER SHEET A2.1
= TEMPERED SAFETY GLAZINGT
= SPANDREL GLASS TO MATCH GRAYS
3
A6.1
______6
A8.1
______
T
SS
1'
0
"
5
'
6
"
6
"
7'
0
"
3' 0"
5" 2' 2" 5"
D1
3' 0"3' 0"
7'
0
"
D2 D3
3' 0"
7'
0
"
D4
3'
7
"
1'
0
"
5
'
0
"
WIDTH
DOOR
D6
PANIC
HARDWARE
W/ BATTERY
POWERED
DOOR ALARM
PROVIDE 30"X34"
KICK PLATE
(BOTH SIDES)
INSULATED
METAL DOOR
PROVIDE
4"WX24"H
TEMPERED
VIEW PANEL
T
NOTE: INTERIOR DOOR AND
DOOR FRAME PAINT, REFER
FINISH P5 ON ROOM FINISH
SCHEDULE SHEET A1.11
PROVIDE 30"X34" KICK
PLATE (BOTH SIDES)
8'
0
"
2' 0" 3' 0"
D5
PANIC
HARDWARE
W/
HARDWIRED
DOOR ALARM
INSULATED
METAL DOOR
PROVIDE
30" X 22"
KICK
PLATE
PROVIDE
30"X34" KICK
PLATE
1'
0
"
5
'
0
"
1
'
0
"
7'
0
"
2
"
2"2"
2"
7
'
0
"
2"2"
F1 F2
GALVANIZED COATING;
PAINT AS SCHEDULED
GALVANIZED COATED; FOR PAINT
FINISH, REFER TO SHEET A1.11
2"2"
2"
8'
0
"
F3
1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES.
2. PROVIDE A 60"x60" MIN. LANDING ON STRIKE SIDE OF DOOR W/ 44" MIN. WIDTH IN
DIRECTION OF TRAVEL.
3. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3 FT. WIDE
BY NOT LESS THAN 6' 8" HIGH CAPABLE OF OPENING 90°. SO THAT THE CLEAR WIDTH OF
THE EXITWAY IS 32" MIN. THRESHOLD TO BE A MAX. 1/4" ABOVE ADJACENT FINISH FLOOR.
4. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. FOR INTERIOR DOOR AND
8 LBS. FOR EXTERIOR DOOR.
5. THE BOTTOM OF ALL DOORS WITHIN 12" OF FLOOR EXCEPT AUTOMATIC AND SLIDING SHALL
HAVE A SMOOTH UNINTERRUPTED SURFACE.
6. PROVIDE LEVER TYPE HARDWARE, PANIC BARS, PUSH PULL ACTIVATING BARS, OR OTHER
HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP
THE OPENING HARDWARE. (30" TO 44" A.F.F.)
1. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 3:5
AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND 1:10.
2. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING
DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS MEASURED USING
AN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED (3" MIN.)
3. LETTERS AND NUMERALS SHALL BE RAISED 1/32 IN. UPPER CASE, SANS SERIF OR SIMPLE
TYPE AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE
AT LEAST 5/8" (16mm) HIGH, BUT NO HIGHER THAN 2 IN. (50mm). PICTOGRAMS SHALL BE
ACCOMPANIED BY THE EQUIVALENT VERVAL DESCRIPTIONS PLACED DIRECTLY BELOW THE
PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 IN. (152mm)
MINIMUM IN HEIGHT.
4. THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL MATTE OR OTHER NON
GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND
EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT
BACKGROUND.
5. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES. SIGNS SHALL
BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE
IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS,
SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE
48" MINIMUM MEASURED FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER OR 60"
MAXIMUM MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER.
MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY APPROACH
WITHIN 3 IN (76mm) OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR
STANDING WITHIN THE SWING OF A DOOR.
SET No. 1
1 CONTINUOUS HINGE PEMKO DFM_83SLF FINISH D
1 DEADLOCK ADAMS RITE MS1850S 310 FINISH 313
1 CORE YALE A600 MK FINISH 613E
1 THUMBTURN YALE S2053 MORTISE THUMBTURN FINISH 613E
1 PULL/PUSH BAR ROCKWOOD BF15847 33 T4HD MOUNTING
FINISH US10B
1 SURFACE CLOSER YALE UNI 4400 690 488 293S FINISH 690
1 THRESHOLD PEMKO HALF SADDLE 2005AV36 (MSES25SS)
FINISH A
**WEATHER STRIPPING PACKAGE PROVIDED BY DOOR AND FRAME
MFR.
1 PLASTIC SIGN: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE
IS OCCUPIED". (IBC 2015 SECTION 1010.1.9.3)
NOTE: DOOR PULL ON 108B ONLY
SET No. 2
1 CONTINUOUS HINGE PEMKO CFM83_HD1 FINISH C
1 ELECTRONIC DIGITAL LOCK TRILOGY T2 DL27 00 IC/US26D
1 CORE YALE A600 MK 626 FINISH 626
1 SURFACE CLOSER YALE 3521T HOLD OPEN THUMBTURN
FINISH 689
2 ARMOR PLATE ROCKWOOD K1050 30 X 34" LDW
FINISH US32D
3 DOOR SILENCER ROCKWOOD 608 FINISH GRY
SET No. 3
1 CONTINUOUS HINGE PEMKO CFM83_HD1 FINISH C
1 EXIT ALARM DEVICE YALE 6100 A ALR EO BSP (EXIT
ONLY) FINISH BSP
1 CYLINDER YALE K640 MORTISE CYLINDER FINISH 626
1 CORE YALE A600 MK 626 FINISH 626
1 SURFACE CLOSER YALE UNI 4400 689 3' 0" DOOR FINISH 689
1 KICK PLATE ROCKWOOD K1050 30 X 34" LDW US32D FINISH US32D
1 THRESHOLD PEMKO 2005AP72 (MSES25SS) FINISH A
1 HEAD SEAL PEMKO 2891APK 36 FINISH A
2 SET OF SEALS PEMKO 303AS84 FINISH A
1 RAIN DRIP PEMKO 346A40 FINISH A
1 DOOR SWEEP PEMKO 3452APK36 FINISH A
SET No. 4
2 CONTINUOUS HINGES PEMKO DFM83SLF FINISH D
2 FLUSH BOLT ROCKWOOD 555 US10B FINISH US10B
1 EXIT ALARM DEVICE ACCENTRA 6160 A ALR 36" EO 613E
(EXIT ONLY) FINISH 613E (NO PUSH BAR ON INACTIVE
LEAF)
1 WIRE HARNESS 60 7700 0290 999 (FOR EXIT ALARM DEVICE)
1 POWER SUPPLY 784 (FOR EXIT ALARM DEVICE)
1 CYLINDER ACCENTRA K660/ LOCKNET LN2049D MORTISE
CYLINDER HOUSING FINISH 613
1 CORE ACCENTRA A600 MK FINISH 613E
1 SURFACE CLOSER ACCENTRA UNI 4400 690 488 6190
FINISH 690
1 OVERHEAD DOOR STOP RIXSON 10 136 613 (INSTALL:
INACTIVE LEAF) FINISH 613
1 KICK PLATE ROCKWOOD K1050 30 X 34" LDW US32D
FINISH US10B (ACTIVE LEAF)
1 KICK PLATE ROCKWOOD K1050 30X 22" LDW US32D FINISH
US10B (INACTIVE LEAF)
2 SET OF SEALS PEMKO 303AS84 (@5200) FINISH D
1 HEAD SEAL PEMKO 2891APK 60 FINISH D
1 THRESHOLD PEMKO HALF SADDLE 2005AV36 FINISH A
1 DOOR SWEEP PEMKO 3452DPK24" FINISH D
1 DOOR SWEEP PEMKO 3452APK36" FINISH A
1 RAIN DRIP PEMKO 346C64 FINISH D
1 DUST PROOF STRIKE ROCKWOOD 570 US10B
FINISH US10B
1 PLASTIC SIGN: "THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED".
2 SECURITRON DPS M BK
SET No. 5
2 STANDARD HINGE MCKINNEY 1502 4 1/2” X 4 1/2" US26D
1 STANDARD HINGE MCKINNEY T4A3786 4 1/2” X 4 1/2” (NRP)
US26D (INSTALL TOP HINGE)
1 LATCHSET YALE AU R 8802FL LH 626 IND
1 COAT HOOK ROCKWOOD 790 US26D
2 DOOR SILENCER ROCKWOOD 608
1. ALL EXITS TO BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY SPECIAL
KNOWLEDGE.
2. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS
ARE PROHIBITED.
3. ALL DOOR HARDWARE IS TO BE ACCESSIBLE BY DISABLED PERSON.
KAWNEER 451UT FRAMING SYSTEM OR EQUAL.
102A 101A
WALK IN
FREEZER
106 COLD VAULT
105
STORAGE
ROOM
103 BACK ROOM
109
PREP AREA
110
CASHIER
108
HALLWAY
111
MEN'S
RESTROOM
102
101B
103
SALES FLOOR
107
101C
101D
102B
108B108AABB
WALK IN
COOLER
104
CO2
BC
S
BC
S
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EL
E
C
T
R
I
C
A
L
PA
N
E
L
EXTERIOR
ROOF ACCESS
LADDER
C
WH
C 1
107
WOMEN'S
RESTROOM
101
KAWNEER TRIFAB 450 2" VENEER SYSTEM GLAZING TO BE MANUFACTURED ACCORDING TO
STOREFRONT MANUFACTURER'S SPECIFICATIONS
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A6.0
PROJECT NUMBER: 24212
ROOM KEY PLAN,
DOOR/ WINDOW
SCHEDULE & TYPES,
AND NOTES
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1/4" = 1' 0"
3WINDOW SCHEDULE
1/4" = 1' 0"
2DOOR TYPES
1/4" = 1' 0"
1FRAME TYPES
HARDWARE NOTES
DOOR SIGNAGE NOTES
ACCESSIBILITY NOTES
HARDWARE SCHEDULE
STOREFRONT NOTES
1/8" = 1' 0"
4DOOR / WINDOWS / ROOM KEY PLAN
GLAZING SCHEDULE
D 1
1
ENTRY DOORS
ABOVE ENTRY DOORS 0.27 3.7 0.25 0.57
SEE DOOR TYPES /
WINDOW SCHED.1"SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4"
LITES TEMPERED AS SHOWN ON ELEVATIONS.
C1 1 RIGHT OF ENTRY DOORS 0.27 3.7 0.25 0.57 8' 4" 7' 4" 1"
VENEER STOREFRONT SYSTEM 1/4" GLAZING (SPANDREL) MATCH STOREFRONT
GLAZING FINISH
C 1 RIGHT OF ENTRY DOORS 0.27 3.7 0.25 0.39/0.57 4' 4" 7' 4" 1"
SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4"
LITES TEMPERED AS SHOWN ON ELEVATIONS.
B2 2 ENTRY DOORS 0.27 3.7 0.25 0.57 3' 0" 7' 0" 1"
SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4"
LITES TEMPERED.
B1 2 ABOVE ENTRY DOORS 0.27 3.7 0.25 0.57 3' 0" 3' 1 3/4" 1"
SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4"
LITES
B 2 LEFT & RIGHT OF ENTRY DOORS 0.27 3.7 0.25 0.57 12' 8" 7' 4" 1"
SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4"
LITES TEMPERED AS SHOWN ON ELEVATIONS.
A 1 LEFT OF ENTRY DOORS 0.27 3.7 0.25 0.39/0.57 16' 10" 7' 4" 1"
SOLARBAN 60 (2) SOLARGRAY + CLEAR 1" UNITS W/ 1/2" AIR SPACE AND TWO 1/4"
LITES TEMPERED AS SHOWN ON ELEVATIONS.
WIDTH HEIGHT THKN.
MARK QTY. GLAZING LOCATION
SUMMER
U FACTOR R VALUE SHGC PF
SIZE NOTES
DOOR SCHEDULE
STOREFRONT VENEER
2' 0" 8' 0" 1 3/4"
111 HALLWAY
3' 0" 8' 0" 1 3/4"D5 INSUL. MTL. PAINT H.M. PAINT F3 4 11/A8.2 2/A8.2 1/A8.2 DOUBLE LEAF DOOR EXIT ONLY
109 BACK ROOM EXTERIOR 3' 0" 7' 0" 1 3/4" D3 INSUL. MTL. PAINT H.M. PAINT F1 3 11/A8.2 2/A8.2 1/A8.2 EXIT DOOR
107 BACK ROOM 3' 0" 7' 0" 1 3/4" D4 H.M. PAINT H.M. PAINT F1 2 7/A8.2 7/A8.2 10/A8.2 WITH 4"x24" TEMPERED ONE WAY GLASS WINDOW
103 STORAGE 3' 0" 7' 0" 1 3/4" D2 H.M. PAINT H.M. PAINT F1 2 7/A8.2 7/A8.2 10/A8.2
102B RESTROOM PART. 2' 4" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED
102A RESTROOM PART. 3' 0" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED
101D RESTROOM PART. 2' 4" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED
101C RESTROOM PART. 2' 4" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED
101B RESTROOM PART. 2' 10" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED
101A RESTROOM PART. 3' 0" 5' 0" 1 3/4" D6 H.M. PAINT H.M. PAINT F2 5 7/A8.2 GALVANIZED COATED FRAME; PAINT AS SCHEDULED
108B STOREFRONT 3' 0" 7' 0" D1 ALUM/GLASS BRONZE ALUM BRONZE 1 4/A8.2 4/A8.2 3/A8.2 SINGLE SWING
108A STOREFRONT 3' 0" 7' 0" D1 ALUM/GLASS BRONZE ALUM BRONZE 1 4/A8.2 4/A8.2 3/A8.2 SINGLE SWING
WIDTH HEIGHT THKN.
SIZE TYPE MATERIAL FINISH MATERIAL FINISH TYPE SET NO. HEAD JAMB SILLMARK ROOM NO.
DOOR FRAME HDW. DETAILS
REMARKS
DOOR SCHEDULE
METAL FLASHING TO
MATCH ADJACENT
WALL COLOR
1/4" CLEARANCE
BETWEEN EDGE OF
PANEL AND FLASHING
1/2" CONT. SEALANT
1 LAYER OF #15
ASPHALT FELT WATER
RESISTIVE BARRIER
NICHIHA FIBER
CEMENT PANEL
NICHIHA 10MM SPACER
FACE FASTENER,
FOLLOW MFRS GUIDELINE
FOR INSTALLTION
STOREFRONT VENEER
SYSTEM BASIS OF
DESIGN: KAWNEER,
TRIFAB 450
5/8" GYP. BD.,
SEE FINISH SCHEDULE
INTERIOREXTERIOR
SIP PANEL SYSTEM
NOTE:
METAL FLASHING IN ALL
AREAS TO BE PROVIDED AND
INSTALLED BY G.C.
SEE FINISH SCHEDULE
SIP PANEL SYSTEM
PRE FINISHED ALUMINUM STOREFRONT
FRAMING WITH 1" INSULATED DOUBLE
PANED GLASS
EXTERIOR
INTERIOR
1/2" CONT. SEALANT, TYP.
STOREFRONT VENEER SYSTEM BASIS
OF DESIGN: KAWNEER, TRIFAB 450
SIP PANEL SYSTEM
SEE FINISH SCHEDULE
NOTE:
1. METAL FLASHING
IN ALL AREAS TO BE
PROVIDED AND
INSTALLED BY G.C.
2. INSTALL NICHIHA
SILL FIRST THEN
WORK LEDGESTONE
UP TO BOTTOM OF
SILL.
METAL FLASHING TO MATCH
ADJACENT WALL COLOR
KURASTONE CLIP MIN. OF
(2) 8 SCREW PER CLIP
KURASTONE PIECE
CONT. SEALANT, TYP.
STOREFRONT VENEER SYSTEM
BASIS OF DESIGN:
KAWNEER, TRIFAB 450
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER EXTERIOR
GRADE PLYWOOD SHEATHING
UPSIDE DOWN ULTIMATE
HORIZONTAL STARTER TRACK
(INSTALLED FIRST)
KURASTONE SILL CHISELED ON UPSIDE DOWN
SILL CHISELED CLIPS ON 5MM SPACER
SILL CHISELED CLIP
KURASTONE CLIP ATTACHED VERTICALLY
CONTINOUS METAL FLASHING
4" MIN. VERTICAL
INTERIOR
EXTERIOR
SEE FINISH SCHEDULE
SIP WALL PANEL(S)
SEE SIP PLANS FOR
PANEL TO PANEL CONNECTIONS
LINE OF SILL CHISELED CAP BELOW (JAMB)
ULTIMATE CLIP, FOLLOW MFRG. FOR INSTALLATION
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER
NICHIHA J MOLD METAL TRIM
CONT. SEALANT, TYP.
STOREFRONT VENEER SYSTEM BASIS
OF DESIGN: KAWNEER, TRIFAB 450
PRE FINISHED ALUMINIUM STOREFRONT
FRAMING WITH 1" SINGLE PANED SPANDREL
GLASS
NICHIHA FIBER CEMENT PANEL
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A6.1
PROJECT NUMBER: 24212
EXTERIOR
ARCHITECTURAL
DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3" = 1' 0"
1STOREFRONT VENEER HEAD
3" = 1' 0"
2STOREFRONT VENEER JAMB
3" = 1' 0"
3STOREFRONT VENEER SILL
3" = 1' 0"
4STOREFRONT VENEER JAMB
3' 1 3/4"
T.O. WAINSCOTT CAP
B.O. BOX AT 6' 0" AFF
PER FIRE DEPT.
VARIES PER ELEV.
T.O.PARAPET
CONTINUOUS 26 GA. 8" HIGH GSM
FLASHING. BOTTOM EDGE TO EXTEND
MIN. 4" BELOW FLOOR SLAB. SET IN
FULL BED OF MASTIC. PAINT EXPOSED
SURFACE TO MATCH FIBER
CEMENT COLOR
SIP WALL
PANELS. SEE SIP SHEETS
SEE FINISH PLANS
SIP WALL
PANEL
SILL GASKET
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL
PANEL
ULTIMATE CLIP
NICHIHA FIBER CEMENT PANEL
8"
CONCRETE FOOTING,
SEE STRUCTURAL
DRAWINGS FOR
SPECIFIC
INFORMATION
ANCHOR BOLT, SEE STRUCT.
SEE CIVIL
AND
LANDSCAPE
MIN. DISTANCE TO HARD
SURFACE
WHERE OCCURS
4"
NICHIHA STARTER FLASHING
NICHIHA HORIZONTAL STARTER TRACK
1/4 " CLEARANCE BETWEEN
EDGE OF PANEL AND FLASHING
SEE STRUCT.
3"
7"
R 10 EDGE OF SLAB
INSULATION
CONTINUOUS 26 GA. 8" HIGH GSM
FLASHING. BOTTOM EDGE TO EXTEND
MIN. 4" BELOW FLOOR SLAB. SET IN
FULL BED OF MASTIC. PAINT EXPOSED
SURFACE TO MATCH FIBER
CEMENT COLOR
SIP WALL
PANELS. SEE SIP SHEETS
SEE FINISH PLANS
SIP WALL
PANEL
SILL GASKET
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL
PANEL
ULTIMATE CLIP
NICHIHA FIBER CEMENT PANEL
8"
CONCRETE FOOTING,
SEE STRUCTURAL
DRAWINGS FOR
SPECIFIC
INFORMATION
ANCHOR BOLT, SEE STRUCT.
SEE CIVIL
AND
LANDSCAPE
MIN. DISTANCE TO HARD
SURFACE
WHERE OCCURS
4"
NICHIHA STARTER FLASHING
NICHIHA HORIZONTAL STARTER TRACK
1/4 " CLEARANCE BETWEEN
EDGE OF PANEL AND FLASHING
SEE STRUCT.
3"
R 10 EDGE OF SLAB
INSULATION
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER OVER SIP
WALL PANEL
KURASTONE CLIP
KURASTONE PIECE
NICHIHA FIBER CEMENT PANEL
METAL FLASHING, SW TOTALLY TAN
NICHIHA STARTER TRACK
1/4" CLEARANCE BETWEEN EDGE
OF PANEL AND FLASHING
FINISH WHERE APPLIES. SEE
FINISH PLAN AND SCHEDULE
SIP WALL PANEL.
SEE SIP SHEETS
NOTE:
1. METAL FLASHING IN ALL AREAS
TO BE PROVIDED AND INSTALLED
BY G.C.
2. INSTALL NICHIHA SILL FIRST
THEN WORK LEDGESTONE UP TO
BOTTOM OF SILL.
UPSIDE DOWN ULTIMATE
HORIZONTAL STARTER TRACK
(INSTALLED FIRST)
KURASTONE SILL CHISELED ON
UPSIDE DOWN SILL CHISELED
CLIPS ON 5MM SPACER
SILL CHISELED CLIP
KURASTONE CLIP ATTACHED
VERTICALLY
CONCRETE FOOTING, SEE
STRUCTURAL DRAWINGS FOR
SPECIFIC INFORMATION
CONTINUOUS 26 GA. 8" HIGH GSM FLASHING.
BOTTOM EDGE TO EXTEND MIN. 4" BELOW
FLOOR SLAB. SET IN FULL BED OF MASTIC.
PAINT EXPOSED SURFACE TO MATCH FIBER
CEMENT COLOR
SEE CIVIL AND
LANDSCAPE
SIP WALL PANEL.
SEE SIP SHEETS
1 LAYER OF #15 ASPHALT FELT WATER
RESISTIVE BARRIER OVER SIP WALL
PANEL
NICHIHA FIBER CEMENT PANEL
NICHIHA STARTER FLASHING
SILL GASKET
FINISH WHERE APPLIES. SEE
FINISH PLAN AND SCHEDULE
MIN. DISTANCE TO HARD SURFACE
WHERE OCCURS
ANCHOR BOLT, SEE STRUCT.
NICHIHA HORIZONTAL STARTER TRACK
FASTNER SPACING 12" O.C.
1/4" CLEARANCE BETWEEN EDGE OF
PANEL AND FLASHING
3"
7"
SEE STRUCT.
4"
8"
R 10 EDGE OF
SLAB INSULATION
1 LAYER OF #15 ASPHALT FELT WATER
RESISTIVE BARRIER OVER SIP WALL
PANEL
NICHIHA CLIP
NICHIHA FIBER CEMENT PANEL
DOUBLE FLANGE SEALANT
BACKER
ATTACH DOUBLE PANEL
FLANGE SEALANT BACKER
TO SHEATHING
REFER TO SIP SHEETS FOR
PANEL CONNECTIONS.
CONTINUOUS SEALANT
SIP WALL PANEL
SEE FINISH SCHEDULE
WALL PANEL STONE PIECE
KURASTONE CLIP
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER OVER SIP
WALL PANEL
NICHIHA CLIP
NICHIHA FIBER CEMENT PANEL
DOUBLE FLANGE SEALANT
BACKER
ATTACH DOUBLE PANEL
FLANGE SEALANT BACKER
TO SHEATHING
CONTINUOUS SEALANT
REFER TO SIP SHEETS FOR
PANEL CONNECTIONS.
SIP WALL PANEL
SEE FINISH SCHEDULE
WATERPROOF SEALANT 1/4" MIN
THICKNESS WITH BACKER ROD
5/8" GYPSUM BOARD
SEE FINISH SCHEDULE
CORNER BEAD, TYP.
HEMMED METAL SILL FLASHING
TO MATCH STOREFRONT COLOR
SEALANT BOTH SIDES
1/4" WOOD SHIM AS
REQUIRED
4 1/2"
SIP WALL PANEL. SEE
SIP SHEETS
SEALANT UNDER FLASHING
NOTE:
1. METAL FLASHING IN ALL AREAS TO BE
PROVIDED AND INSTALLED BY G.C.
2. INSTALL NICHIHA SILL FIRST THEN
WORK LEDGESTONE UP TO BOTTOM OF
SILL.
EXTERIORINTERIOR PRE FINISHED ALUMINUM STOREFRONT
FRAMING WITH 1" INSULATED DOUBLE
PANED GLASS (TYP.)
UPSIDE DOWN ULTIMATE
HORIZONTAL STARTER TRACK
(INSTALLED FIRST)
KURASTONE CLIP ATTACHED
VERTICALLY
KURASTONE CLIP
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER OVER
SIP WALL PANEL
KURASTONE PIECE
KURASTONE SILL CHISELED ON
UPSIDE DOWN SILL CHISELED CLIPS
ON 5MM SPACER
SILL CHISELED CLIP
PER FOOT
SLOPE 1/4"
SIP WALL PANEL
FINISH WHERE APPLIES. SEE FINISH PLAN
BLOCKING AS REQUIRED. SEE SIP VENDOR SHEETS
SIP WALL PANEL
1/4" CHALKING WITH BACKER ROD
1/4" CHALKING WITH BACKER ROD
PROVIDE 26 GA. GSM
FLASHING ALL AROUND
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER
OUTLINE OF KNOX BOX
NICHIHA FIBER CEMENT PANEL
NICHIHA 10MM SPACER
BLOCKING AS REQUIRED. SEE
SIP VENDOR SHEETS
METAL FLASHING
FASTENER AND SPACER
FACE FASTENER
TOGGLE BOLT BY SIP VENDOR
(SPACING AT ACCESS
DOOR ONLY)
26" O.C.
WOOD CEILING JOIST OR TRUSS
WOOD SCREW
WOOD CEILING JOIST, OR TRUSS
WOOD SCREWS IN HINGES
2x BLOCKING BEYOND
LOCK
SOFFIT FINISH TYPE, PER
REFLECTED CEILING PLAN
SOFFIT FINISH TYPE, PER
REFLECTED CEILING PLAN
TRIMLESS FLUSH MOUNTED
ACCESS DOOR, PAINTED TO
MATCH ADJACENT CEILING
(SPACING AT ACCESS DOOR ONLY)
26" O.C.
CONCRETE FOOTING, SEE
STRUCTURAL DRAWINGS FOR
SPECIFIC INFORMATION
CONTINUOUS 26 GA. 8" HIGH GSM FLASHING.
BOTTOM EDGE TO EXTEND MIN. 4" BELOW
FLOOR SLAB. SET IN FULL BED OF MASTIC.
PAINT EXPOSED SURFACE TO MATCH FIBER
CEMENT COLOR
SEE CIVIL AND
LANDSCAPE
SIP WALL PANEL.
SEE SIP SHEETS
1 LAYER OF #15 ASPHALT FELT WATER
RESISTIVE BARRIER OVER SIP WALL
PANEL
KURASTONE CLIP
KURASTONE PIECE
NICHIHA STARTER FLASHING
SILL GASKET
FINISH WHERE APPLIES. SEE
FINISH PLAN AND SCHEDULE
MIN. DISTANCE TO HARD SURFACE
WHERE OCCURS
ANCHOR BOLT, SEE STRUCT.
NICHIHA HORIZONTAL STARTER TRACK
FASTNER SPACING 12" O.C.
1/4" CLEARANCE BETWEEN EDGE OF
PANEL AND FLASHING
3"
7"
SEE STRUCT.
4"
8"
1/2"
R 10 EDGE OF SLAB
INSULATION
12" WIDE 20 GA. GALV.
ANCHOR CLIPS 3' 0" O.C.
8" WIDE CONCEALED
SPLICE PLATE AT
EACH JOINT
PRE FINISHED METAL
COPING COVER, 12"
LENGTHS
SLOPE 3/4"
PER FOOT
NICHIHA FIBER
CEMENT PANEL
CLIP FASTENED ON
STUD
FACE FASTENER
SPACER
WOOD BLOCKING,
AS REQ
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER EXTERIOR
GRADE PLYWOOD
SHEATHING
TPO ROOFING TO CONTINUE
UNDERNEATH OF METAL COPING
AND RUNNING VERTICALLY
DOWN FACE BEHIND CLEAT.
INSTALL PER MFR REQUIREMENTS
SIP WALL PANEL. SEE SIP
VENDOR DRAWINGS
METAL FLASHING
CONT. SEALANT
SEALANT, TYP.
6 5/8"
1"
6"
#9 X 1 1/2" STAINLESS
STEEL FASTENER
(PROVIDED), TYP.
3 1/2"
1'
0
"
7"
3
1
/
2
"
1
1
/
2
"
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A8.1
PROJECT NUMBER: 24212
ARCHITECTURAL
DETAILS (EXTERIOR)
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3" = 1' 0"
12BASE SILL DETAIL FOR FRONT ELEVATION
3" = 1' 0"
11PERIMETER INSULATION DETAIL
3" = 1' 0"
9TRANSITION DETAIL
3" = 1' 0"
10BASE SILL DETAIL FOR REAR AND SIDE ELEVATION
3" = 1' 0"
7TYP. TRANSITION DETAIL PLAN
1 1/2" = 1' 0"
4NOT USED
3" = 1' 0"
5TYP. CONTROL/EXPANSION JOINT DETAIL
3" = 1' 0"
6WINDOW SILL DETAIL
3" = 1' 0"
1RECESS BOX DETAIL
3" = 1' 0"
2CEILING ACCESS PANEL
3" = 1' 0"
8BASE SILL DETAIL FOR FRONT ELEVATION
1 1/2" = 1' 0"
3PARAPET DETAIL
DOOR W/ PAINT FINISH, SEE
DOOR SCHEDULE
HOLLOW METAL DOOR FRAME
BEYOND
WEATHER STRIPPING
HALF SADDLE ALUMINUM
THRESHOLD, SEE SPECS
FLOORING AS SCHEDULED
CONCRETE SLAB, SEE
STRUCT.
TOP OF CONC.
1:2 SLOPE, MAX.
1/2" EXPANSION
MATERIAL
1/
4
"
1/
4
"
1/
2
"
M
A
X
.
1" TEMPERED SAFETY GLAZING
DOOR FRAME, FNISH TO MATCH
STOREFRONT
WEATHER STRIPPING
HALF SADDLE ALUMINUM
THRESHOLD SET IN A CONT.
SEALANT BED
TOP OF CONCRETE
FLOORING AS SCHEDULED
2:1 MAX
1/
4
"
1/
4
"
1/
2
"
M
A
X
1/2" MAX THRESHOLD, SET IN FULL
BED OF MASTIC
1/2" PRE MOLD EXPANSION JOINT
WITH SEALANT
4 1/2"
2"
PRE FINISHED ALUMINUM
STOREFRONT FRAMING WITH 1"
INSULATED DOUBLE PANED GLASS
DOOR METAL STOP
DOOR FRAME, FINISH TO MATCH
STOREFRONT
1" THICK TEMPERED
GLASS DOOR
(INTERIOR)(EXTERIOR)
2"
1/2" OVERLAP (TYP.)
.
.
DOUBLE 3 5/8" METAL STUDS AT JAMB, TYP.
TILE FINISH WHERE APPLICABLE
6"
SEE PLAN FOR WALL TYPE
SEALANT, TYP.
TILE FINISH WHERE APPLICABLE
JAMB ANCHOR
(SINGLE SWING)
PRE FINISHED ALUMINUM
STOREFRONT SYSTEM
PRE FINISHED ALUMINUM
STOREFRONT FRAMING WITH 1'
INSULATED DOUBLE PANED
GLASS
(VERTICAL)
4 1/2"
2"
PRE FINISHED ALUMINUM
STOREFRONT SYSTEM
(HORIZONTAL)
4
1
/
2
"
PRE FINISHED ALUMINUM
STOREFRONT SYSTEM WITH 1"
INSULATED DOUBLE PANED
GLASS
INTERIOR DOOR PER
DOOR SCHEDULE
1/
2
"
FLOOR FINISH PER
FIN.SCHEDULE
CHANGE FLOOR FINISH AT
CENTRLIINE OF DOOR
H.M. FRAME BEYOND
(PAINT)
TRANSITION STRIP
CONC. FLOOR SLAB
(SINGLE SWING)
4 1/2"
2"
NICHIHA FIBER CEMENT PANEL
METAL FLASHING, COLOR TO
MATCH TOTALLY TAN
NICHIHA 10MM SPACER
1/4" CLEARANCE BETWEEN
EDGE OF PANEL AND FLASHING
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL
PANEL
SEALANT WITH
BACKER ROD
FACE FASTENER
1
5
/
8
"
INTERIOREXTERIOR
5/8" GYP. BD.,
SEE FINISH SCHEDULE
GLULAM BEAM,
SEE SIP SHEETS
1/4" SHIMS
AS REQUIRED
ALUMINUM STOREFRONT SYSTEM
CORNER BEAD, TYP.
CONT. SEALANT
PRE FINISHED ALUMINUM
STOREFRONT FRAMING WITH
1" INSULATED DOUBLE
PANED GLASS
2"5/8"
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL PANEL
SIP WALL PANEL
TILE WHERE APPLICABLE
CONT. SEAL CONT. EACH SIDE
KURASTONE WALL PANEL
WAINSCOT. INSTALL PER MFR.
REQUIREMENTS.
CLIP AT VERTICAL JOINTS AND
WITHIN 3" OF TERMINATION
EDGES
DOOR, SEE DOOR SCHEDULE
EXTERIOR
INTERIOR
1/4" BACK BEND (TYP.)
SHIM AS REQUIRED
HOLLOW METAL FRAME,
PROVIDE MIN. OF 3 ANCHORS
L ANGLE EDGING TO BE
PROVIDED BY G.C.
LINE OF SILL CHISELED CAP
ABOVE. INSTALL PER MFR.
REQUIREMENTS.
2"
5/
8
"
1/
4
"
NICHIHA FIBER CEMENT PANEL
METAL FLASHING
1/4" CLEARANCE BETWEEN EDGE
OF PANEL AND FLASHING
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL
PANEL OSB SHEATHING
SEALANT WITH
BACKER ROD
ALUMINUM
EXTRUDED RAIN
DROP GUARD
NOTE:
METAL FLASHING IN ALL AREAS TO
BE PROVIDED AND INSTALLED BY
G.C.
NICHIHA 10MM SPACER
FACE FASTENER
INTERIOREXTERIOR
SEE FINISH SCHEDULE
2X WOOD BLOCK,
SEE SIP VENDOR
SHEETS
CONT. SEALANT
SIP WALL PANEL
HOLLOW METAL FRAME,
PROVIDE MIN. OF 3 ANCHORS
DOOR, SEE DOOR
SCHEDULE
4
1
/
2
"
2"EXTERIOR
INTERIOR
NICHIHA FIBER CEMENT PANEL
SEALANT BOTH SIDES
SEE FINISH SCHEDULE
SIP WALL PANEL
1/4" SHIMS AS REQUIRED
ALUMINUM STOREFRONT SYSTEM
ULTIMATE CLIP
CORNER BEAD, TYP.
NICHIHA J MOLD METAL
TRIM
LINE OF SILL CHISELED CAP
BELOW (JAMB)
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER
PRE FINISHED ALUMINUM STOREFRONT
FRAMING WITH 1" INSULATED DOUBLE
PANED GLASS
2"5/8"
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL PANEL
SIP WALL PANEL
TILE WHERE APPLICABLE
CONT. SEAL CONT. EACH SIDE
NICHIHA FIBER CEMENT PANEL
ULTIMATE CLIP
DOOR, SEE DOOR SCHEDULE
EXTERIOR
INTERIOR
1/4" BACK BEND (TYP.)
SHIM AS REQUIRED
HOLLOW METAL FRAME,
PROVIDE MIN. OF 3 ANCHORS
NICHIHA J MOLD METAL
TRIM
LINE OF SILL CHISELED CAP
BELOW. INSTALL PER MFR.
REQUIREMENTS.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A8.2
PROJECT NUMBER: 24212
ARCHITECTURAL
DETAILS
(EXTERIOR/INTERIOR)
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3" = 1' 0"
1THRESHOLD AT EXERIOR DOOR
3" = 1' 0"
3THRESHOLD AT STOREFRONT DOOR
3" = 1' 0"
4HEAD AT STOREFRONT (JAMB SIM.)
3" = 1' 0"
7INTERIOR DOOR JAMB (HEAD SIM.)
3" = 1' 0"
8NOT USED
3" = 1' 0"
9MULLION DETAIL
3" = 1' 0"
10INTERIOR DOOR THRESHOLD
3" = 1' 0"
12ALUMINUM WINDOW HEAD
3" = 1' 0"
2JAMB AT H.M. DOOR
3" = 1' 0"
11H.M. DOOR HEAD DETAIL
3" = 1' 0"
6ALUMINIUM WINDOW JAMB DETAIL
3" = 1' 0"
5JAMB AT H.M. DOOR
VARIES PER ELEV.
T.O. PARAPET
+12' 2"
B.O. SOFFIT
NOTE:
G.C. TO PROVIDE HILTI "SMOKE AND
ACOUSTIC SEALANT CP 506" AT
THROUGH/ PIPING/ DUCTWORK
PENETRATIONS OF DRAFT STOP.
PLYWOOD SHEATHING
2 10d EACH STUD
MANUFACTURED TRUSSES
PER PLANS
2x4 @ 16" O.C. FLAT
MIN. 1/2" THK. GYPSUM
BOARD DRAFTSTOP
2 10d EACH STUD
GYP. BOARD OR TILE
CEILING FINISH
CONTINUOUS BEAD OF SEALANT
STAINLESS STEEL CLAMPING RING
PIPE
PREMOLDED TPO PIPE FLASHING
FASTENERS W/ PLATE @12" O.C.
CONTINUOUS WELD
EDGE SEALANT
SIP ROOF PANEL
TPO MEMBRANE ROOFING
1" TYP.
12
"
M
I
N
.
PRESSURE TREATED WOOD NAILER
INTERIOREXTERIOR
ALUMINUM
STOREFRONT SYSTEM
3" VTR PER PLUMBING
INNER SECTION OF 2
PIECE PRE FINISHED
PIPE CHASE
ACOUSTICAL ADHESIVE
FOAM TAPE W/
SEALANT EACH SIDE
OUTER SECTION OF 2
PIECE PRE FINISHED
PIPE CHASE
4 1/2"
(VERTICAL)
PRE FINISHED ALUM.
STOREFRONT SYSTEM
PRE FINISHED ALUMINUM
STOREFRONT FRAMING
WITH 1" INSULATED
DOUBLE PANED GLASS
2 PIECE PRE FINISHED
ALUMINUM PIPE CHASE
3" VTR PER PLUMBING
LINE OF WALL BELOW
ACOUSTICAL ADHESIVE
FOAM TAPE
SEALANT EACH SIDE
5"
8"
4
1
/
2
"
8"
M
I
N
.
A
B
O
V
E
H
I
G
H
E
S
T
AD
J
A
C
E
N
T
R
O
O
F
S
U
R
F
A
C
E
4"
NOTE:
1. FLASHING REQ'TS SHALL BE VERIFIED W/
UNIT TYPE BEFORE FABRICATION.
ROOFING MEMBRANE
1/2" THICK. 1" WIDE TAPE
SEALANT, CONT., TOP &
BOTTOM OF FLASHING
CONT. GALV. METAL FLASHING,
VERIFY SHAPE WITH UNIT DESIGN
PRE FAB MTL. CURB W/ WD.
NAILER AND INSULATION, CURB
SHALL OFFSET ROOF SLOPE
INSULATION CRICKET AT
UPHILL SIDE, 4" MIN. RISE,
SEE DETAIL 4/A8.3
MECH. UNIT ATTACH TO
CURB PER MANUF.
REQUIREMENTS
CONT. SEALANT
FRAMING, SEE SIP
SHEETS
FLASHING MEMBRANE,
SEE DETAIL 10/A8.3
SIP ROOF PANEL
TPO BONDING
ADHESIVE
TPO MEMBRANE
WIDE WELDED SPLICETPO BONDING
ADHESIVE
TPO ROOFING TO CONTINUE
TO UNDERNEATH OF METAL
COPING. INSTALL PER MFR
REQUIREMENTS
SIP WALL PANEL. SEE SIP
VENDOR SHEETS
SIP ROOF PANEL
HD OR HD PLUS SEAM
PLATE AND ROOF SYSTEM
FASTENER AT 12" O.C.
MAX.
6"MAX.
MIN.
1/2"
1/4" COVER BOARD
GC NOTE:
DETAIL WILL CHANGE BASED ON TPO SPECIFICATION.
REFLECT COVER BOARD PER TPO REQUIREMENTS.
12
"
T
Y
P
.
1
2
"
T
Y
P
.
9 3_8"
4"
1' 6"
9
3
/
8
"
2"x3/8" BENT BAR AT 1/3
POINTS, BOTH SIDES, PAINTED
LINE OF WALL
2"x3/8" STEEL BAR, PAINTED
#6 REBAR AT 12" O.C.
VERTICAL, PAINTED
3/8"x3" EXPN. BOLT TO FLOOR,
PAINTED
2"x3/8" STEEL BAR, WELD TO
UP RIGHT AND EXP. BOLT TO
FLOOR, PAINTED
#6 REBAR AT 12" O.C.
VERTICAL, PAINTED
2"x3/8" STEEL BAR, WELD TO
UP RIGHT AND EXP. BOLT TO
FLOOR
LINE OF WALL
5"
GUTTER BEYOND. SEE 9/A8.3
4"
A
SECTION 'A' (PLAN)
CL
CL
SIDE SECTION
AFFL
3/8" DIA. STAINLESS OR GALV.
THREADED ROD W/ WASHERS,
INCLUDE 3/4" OD TUBE AS
CRUSH SLEEVE . REFER TO SIP
VENDOR DWGS.
3/8" DIA. STAINLESS OR GALV.
THREADED ROD W/ WASHERS,
INCLUDE 3/4" OD TUBE AS
CRUSH SLEEVE . REFER TO SIP
VENDOR DWGS.
ROOFING MEMBRANE
WALL OR CURB
OPENING
TAPERED INSULATION
TAPERED
INSULATION
SIP ROOF
PANEL
TPO ROOFING
MEMBRANE
10
"
NOTE:
METAL FLASHING IN ALL AREAS TO
BE PROVIDED AND INSTALLED BY
G.C.
6 5/8"
SIP PARAPET/
WALL PANEL. SEE
SIP PLANS.
SLOPE 3/4"
PRE FINISHED
SNAP ON METAL
FASCIA, COUNTER
FLASHING, RE: EXT.
ELEVATIONS PER FOOT
NICHIHA
FIBER
CEMENT PANEL
FACE FASTENER
SPACER
CLIP
FASTENED ON
STUD
1 LAYER OF #15
ASPHALT FELT WATER
RESISTIVE BARRIER
OVER EXTERIOR GRADE
SIP WALL PANEL
WOOD
BLOCKING AS
REQUIRED
TPO ROOFING TO CONTINUE
UNDERNEATH OF METAL FASCIA
AND RUNNING VERTICALLY
DOWN FACE BEHIND CLEAT.
INSTALL PER MFR REQUIREMENTS
NICHIHA FIBER
CEMENT PANEL
1 LAYER OF #15
ASPHALT FELT WATER
RESISTIVE BARRIER
OVER OSB SHEATHING
OVERHANG FLASHING
BY NICHIHA VENDOR
2X BLOCKING,
SEE SIP VENDOR
SHEETS
NICHIHA FIBER CEMENT PANEL,
TUFF BLOCK, COLOR TO MATCH TOASTY
SW#6095
FASTENER
SPACER
NICHIHA
FIBER CEMENT PANEL
SEALANT
1 LAYER OF #15
ASPHALT FELT
WATER RESISTIVE
BARRIER
FACE FASTENER
1/4" REQUIRED
CLEARANCE
PRE MANUFACTURED WOOD
TRUSS. SEE SIP VENDOR
SHEETS
NICHIHA 10MM SPACER
1/
4
"
NICHIHA 10MM SPACER 4" WIDE x CONT. SOFFIT VENT,
W/CORROSION RESISTANT METAL
MESH W/1/4" MAX. OPENINGS, SEE
REFLECTED CEILING PLAN FOR
LENGTHS, LOCATIONS. PAINT TO
MATCH SOFFITREFER TO FASTENING REQUIREMENTS
FOR SOFFIT APPLICATION IN THE
INSTALLATION GUIDELINE
NICHIHA FIBER CEMENT PANEL
WOOD BLOCKING, TYP.
THRU WALL METAL
EMERGENCY OVERFLOW
SCUPPER, PROVIDE
FLASHING AT OPEN ENDS.
SEE EXT. ELEV. FOR PAINT
COLOR
SIP WALL PANEL
ROOFING MEMBRANE
OVER PLYWOOD
SHEATHING
EXT. GRADE PLYWOOD
WOOD BLOCKING, TYP.
SIP ROOF PANEL
PROVIDE CLOSURE FLANGE
SURROUND, SEAL AT PERIMETER.
SEE EXT. ELEV. FOR PAINT COLOR
PROVIDE CLOSURE FLANGE
SURROUND, SEAL AT PERIMETER.
SEE EXT. ELEV. FOR PAINT COLOR
WOOD BLOCKING
AS REQUIRED
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER, TYP.
NICHIHA 10MM SPACER
CLIP FASTENED ON STUD
FACE FASTENERWOOD TRUSS
1_4" REQUIRED CLEARANCE
REFER TO SHEET METAL & AIR
CONDITIONING CONTRACTOR'S
NATIONAL ASSOCIATION "SMACNA"
DETAILS FOR OVERFLOW
INSTALLATION
FLANGE TO OVERLAP 1/4" WITH FIBER CEMENT
FACE FASTENER
SIP WALL
PANEL
1/
4
"
8"
1/
4
"
2"
2X WOOD
BLOCKING, TYP.
SIP ROOF PANEL
SIP WALL PANEL
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER,
TYP.
CLIP FASTENED ON STUD
FACE FASTENER
LEADER BOX, SEE
PLUMBING
DWGS.
PT WOOD
BLOCKING,TYP.THRU WALL METAL
SCUPPER, SEE EXT.
ELEV. FOR PAINT
COLOR
SIP
WALL
PANEL
ROOFING
MEMBRANE
OVER PLYWOOD
SHEATHINGWOOD
BLOCKING
AS REQUIRED
NICHIHA 10MM SPACER
NICHIHA FIBER CEMENT PANEL
FACE FASTENER 10"
1/
4
"
1/
4
"
8"
10"
10
"
5"
4"
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A8.3
PROJECT NUMBER: 24212
EXTERIOR
ARCHITECTURAL
DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1 1/2" = 1' 0"
1DRAFT STOP
1 1/2" = 1' 0"
8SMALL PIPE PENETRATION
3" = 1' 0"
5ALUMINIUM WINDOW HEAD DETAIL
3" = 1' 0"
6MULLION DETAIL
1 1/2" = 1' 0"
11ROOF CURB DETAIL
6" = 1' 0"
10SINGLE PLY ROOFING AT PARAPET WALL
1 1/2" = 1' 0"
7ROOF LADDER DETAIL
6" = 1' 0"
4TAPERED INSULATION CRICKET
1 1/2" = 1' 0"
3PARAPET DETAIL
3" = 1' 0"
2OVERHANG FLASHING DETAIL
1 1/2" = 1' 0"
12OVERFLOW SCUPPER DETAIL
1 1/2" = 1' 0"
9SCUPPER DETAIL
5' 2 1/2"
A.F.F.
4' 2 1/2"
A.F.F.
2' 9"
A.F.F.
EL. SEE PLAN
EL. +7' 4"
EL. +6' 6"
EL. +4' 6"
EL. SEE PLAN
EL. ±7' 4"
MENWOMEN
GRADE 2 BRAILLE
3/4" SIZE LETTERS IN
HELVETICA FONT
ATTACH WITH 1/2" CARRIAGE
BOLT WITH LOCKING NUT @ EA
CORNER
8"
8"
2"2"
8"
8"
CARE MUST BE TAKEN
TO AVOID
SUFFOCATION &
ASPHYXIATION
CO2 STORAGE AREA
2
NON-FLAMMABLE
GAS
2187
3
0
0
SA
12"x10" SIGN
FONT: ARIAL BLACK
11"x11" SIGN
FONT: ARIAL BLACK
5.5"x5.5" SIGN
FONT: ARIAL BLACK
SQUARES: 2.75"x2.75"
WHITE LETTERING
(FONT SIZE: 1 1/2")
BLUE VINYL SQ.
(FONT SIZE: 1 1/2")
WHITE LETTERING
(FONT SIZE: 1 1/8")
RED VINYL
BLACK VINYL
BLACK LETTERING
(FONT SIZE: 5/8")
BLACK LETTERING
(FONT SIZE: 1/2")
GREEN VINYL
WHITE VINYL 1/8" BORDER
GREEN VINYL
WHITE LETTERING
(FONT SIZE: 3/4")
1"x1" WHITE SQUARES w/
BLACK LETTERING
(FONT SIZE: 3/4")
RED VINYL SQ.
(FONT SIZE: 1 1/2")
YELLOW VINYL SQ.
(FONT SIZE: 1 1/2")
WHITE VINYL SQ.
(FONT SIZE: 3/4")
ALL LETTERING TO BE BLACK
ON THIS SIGN
SIP ROOF PANEL SYSTEM. SEE
SIP VENDOR SHEETS
362S137 33 STEEL STUD
BLOCKING AT 4' 0" O.C.
WITH SIMPSON SFC EACH END
14 GA. CONTINUOUS BENT PLATE
OR DEEP LEG 14 GA SLIP TRACK
BY STUD MFR.
ROOF FRAMING, SEE STRUCTURAL
BLOCKING AT MID SPAN (TYP.)
SUSPENDED ACOUSTICAL
CEILING TILE
5/8" GYP. BD. TO ROOF STRUCTURE
ON 3 5/8" 20 GA. METAL STUDS AT
16" O.C. (WHERE OCC.) (SEE FINISH
SCHEDULE)
3 1/2" THK. ACOUSTICAL BATT
INSULATION
BOTTOM TRACK WITH .145 DIA. x
1 1/4" POWER DRIVEN
FASTENER AT 24" O.C. PER ICC
ESR 2269
FINISH FLOOR
NOTE:
1. PROVIDE 1/2" PLYWOOD WITH
1/4" SHEET ROCK FOR FOUNTAIN
WALL AT THE SIDE OF SALES
AREA.
#8 SMS EA. SIDE
SE
E
P
L
A
N
SIP ROOF PANEL SYSTEM. SEE SIP VENDOR SHEETS
2 #10 X 1 1/2" SCREWS
AT EACH JOINT OR BLOCK
14 GA. CONTINUOUS BENT PLATE
OR DEEP LEG 14 GA SLIP TRACK
BY STUD MFR.
CONT. 16 GAUGE STEEL TRACK WITH 3 #10 TEK
SCREWS AT EACH STUD AND #10 SCREWS AT 12"
O.C. TO BLOCKING.
5 1/2" THK. ACOUSTICAL BATT INSULATION
2 #10 SCREWS AT EACH JOIST
(ONE TOP, ONE BOTTOM)
5/8" GYP. BD. OVER 6" 20 GA METAL
STUD AT 24" O.C.
BLOCKING AT MID SPAN (TYP.)
5/8" GYP. BD. ON 6" OR 3 5/8" 20 GA. METAL
STUDS AT 16" O.C. (SEE FINISH SCHEDULE)
BOTTOM TRACK WITH .145 DIA. x 1 1/4" POWER
DRIVEN FASTENER AT 24" O.C. PER ICC ESR 2269
BASE, SEE SCHEDULE
FIN. FLR. SEE SCHEDULE
NOTE:
1. PROVIDE MOISTURE RESISTANT GYPSUM
BOARD FOR ALL RESTROOM WALLS.
10
A9.1
______HSS 3"x3"x3/16" STEEL POST
ATTACH STUD EACH SIDE TO POST
W/ #12 TEX SCREW @ 16" O.C.
SPACED VERTICALLY
5/8" MOISTURE RESISTANT GYP. BD.
AT ALL RESTROOM WALLS
TILE FINISH
NOTE:
ALL METAL STUDS MEET ESR 3064
REQUIREMENTS.
3 5/8" 20 GA METAL STUDS AT
16" O.C. METAL STUDS PER
ICC ES ESR=3069P
CERAMIC TILE IN THIN SET
GROUT, TYP.
3 5/8" 20 GA. METAL STUDS AT 16"
O.C. METAL STUDS PER ICC ES
ESR 3069P
3 1/2" THK. ACOUSTICAL BATT
INSULATION
ROOF STRUCTURE
362S137 33 STEEL STUD
BLOCKING AT 4' 0" O.C.
WITH SIMPSON SFC EACH END
14 GA. CONTINUOUS BENT PLATE
OR DEEP LEG 14 GA SLIP TRACK
BY STUD MFR.
ROOF FRAMING. SEE STRUCTURAL
14 GA. CONTINUOUS BENT PLATE
OR DEEP LEG 14 GA SLIP TRACK
BY STUD MFR.
A. STUD PARALLEL TO TRUSS
B. STUD PERPENDICULAR TO TRUSS
2 #10 X 1 1/2" SCREWS
AT EACH JOINT OR BLOCK
#8 SMS EA. SIDE
ROOF STRUCTURE
2 #10 X 1 1/2" SCREWS
AT EACH JOINT OR BLOCK
ROOF FRAMING, SEE SIP SHEETS
#8 SMS EA. SIDE
3 5/8" METAL STUD, BRACE AT EACH
TRUSS
1"
M
I
N
.
MI
N
.
1"
C
L
E
A
R
1"
M
I
N
.
MI
N
.
1"
C
L
E
A
R
SIP ROOF PANEL SYSTEM.
SEE SIP VENDOR SHEETS
CONT. SLIP TRACK w/ (2) #10
WOOD SCREWS TO TRUSS
#8 SMS EA. SIDE
2 #10 SCREWS
(ONE TOP, ONE BOTTOM)
5/8" GYP. BD. ON METAL STUDS
(WHERE OCCURS).
SEE FINISH SCHED.
SUSPENDED A.C.T. OR GYP.
BD. CEILING (WHERE OCCURS)
3 5/8" METAL STUDS PER
ESR 2281
CONT. FLOOR TRACK WITH
POWER DRIVEN ANCHOR AT
24" O.C. PER ICC ESR 2269
FIN. FLR. SEE SCHEDULE
T/ STUD
SE
E
P
L
A
N
MI
N
.
6"
7
A9.1
______
7B
A9.1
______
7A
A9.1
______
5/8" MOISTURE RESISTANT GYP.
BD. OVER 6" 20 GA METAL STUD
AT 24" O.C.
SCHLUTER TRIM ON ALL
INSIDE/OUTSIDE TILE CORNERS,
TYP.
5/8" MOISTURE RESISTANT GYP. BD. BOTH
SIDES. FRP TILES, BOTH SIDES, TOP AND
BOTTOM. (SEE FINISH SCHEDULE, A1.11)
POST BEYOND
PORCELAIN TILE IN THIN SET GROUT.
(SEE FINISH SCHEDULE)
3 5/8" STUDS AT 16" O.C.
W/ TRACK T&B
362S162 33 & 362T150 33 BOXED
T&B OF WALL. CLIP TO SUPPORTS W/
2X2X12GAx3" LG ANGLES EA. END
USING (3) #12 SCREWS EA. LEG
SE
E
P
L
A
N
1'
8
"
ALUMINUM TRIM MOLDINGS
(REFER TO FINISH SCHEDULE,
A1.11)
PAINT (REFER TO
FINISH SCHEDULE, A1.11)
MI
N
6"
MI
N
6"
SE
E
P
L
A
N
REFER TO DETAIL 8/A9.1
FOR CONNECTION
3 1/2" THK ACOUSTICAL BATT INSULATION
CONT. 16 GA STEEL TRACK WITH 3 #10 TEK
SCREWS AT EACH STUD AND #10 SCREWS
AT 12" O.C. TO BLOCKING
2 #10 SCREWS
(ONE TOP, ONE BOTTOM)
5/8" GYP. BD. TO 6" O.C. ON 3 5/8" 20 GA
METAL STUDS AT 16" O.C.
SUSPENDED ACOUSTICAL TILE CEILING
(BOTH SIDES FOR PREP AREA ONLY)
SEE FINISH SCHEDULE
BOTTOM TRACK WITH .145 DIA x 1 1/4"
POWER DRIVEN FASTENER AT 24" O.C.
PER ICC ESR 2269
FIN. FLR. SEE SCHEDULE
BASE. SEE SCHEDULE
5/8" GYP. BD. OVER 6" 20 GA METAL STUD
AT 24" O.C.
CEILING WHERE APPLICABLE
BLOCKING AT MID SPAN (TYP.)
NOTE:
1. PROVIDE MOISTURE RESISTANT GYP. BD.
FOR ALL RESTROOM SIDE WALLS.
2. PROVIDE 6" 20 GA. METAL STUDS FOR
BACKROOM WHERE PLUMBING IS NEEDED.
SIP ROOF PANEL SYSTEM. SEE SIP
VENDOR SHEETS
5/8" GYP. BD. ON 3 5/8" 20 GA
METAL STUDS AT 16" O.C. (SEE
FINISH SCHED). METAL STUDS
PER ESR 2281
SUSPENDED ACOUSTICAL TILE
CEILING
3 1/2" CAL BATT INSULATION
BOTTOM TRACK WITH .145 DIA x 1
1/4" POWER DRIVEN FASTENER AT
24" O.C. PER ICC ESR 2269
FIN. FLR. SEE SCHEDULE
BASE. SEE SCHEDULE
CONT. SLIP TRACK w/ (2) #10 WOOD
SCREWS TO TRUSS6"
MI
N
6"
MI
N
T/ STUD
#8 SMS EA. SIDE
5/8" MOISTURE
RESISTANT GYP. BD.
OVER 1/4" FRT
PLYWOOD OVER HSS
3"x3"x3/16" STEEL
POST
CERAMIC TILE IN
THIN SET GROUT,
TYP.
DETAIL B
3"
3"
HSS 3" X 3" X 3/16" STEEL
POST
5"X5"X3/8" THK. A36
STEEL PLATE
DETAIL 'A'
3/16"
3/16"
T/SLAB
(4) #3 x 3 5/8" LG
REBAR INSTALL W/ SET
XP EPOXY3
5
/
8
"
2"
2
"
3 5/8" 20 GA. METAL STUD
CERAMIC TILE
SCHLUTER TRIM
5/8" MOISTURE RESISTANT GYP.
BD.
DOOR FRAME
SHIMDETAIL C
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A9.1
PROJECT NUMBER: 24212
INTERIOR
ARCHITECTURAL
DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3" = 1' 0"
1RESTROOM SIGNS
1 1/2" = 1' 0"
2CO2 SIGN DETAILS
1" = 1' 0"
3SECTION AT WALL TYPE A
1" = 1' 0"
6SECTION AT WALL TYPE B
1" = 1' 0"
7RESTROOM PARTITION WALL (PLAN VIEW)
1" = 1' 0"
8TYPICAL STUDS CONNECTION DETAIL
1" = 1' 0"
9SECTION AT WALL TYPE C
1" = 1' 0"
10SECTION AT WALL TYPE F
1" = 1' 0"
11SECTION AT WALL TYPE E
1" = 1' 0"
12SECTION AT WALL TYPE D
1" = 1' 0"
4NOT USED
1" = 1' 0"
5NOT USED
SEE RCP
.
VARIES
B.O. ROOF DECK/STRUCTURE
VARIES
REFER TO CLG PLAN
10 '-10"
A.F.F.
10 '6"
A.F.F.
SEE RCP
A.F.F.
SEE RCP
A.F.F.
SEE PLAN
A.F.F.
+10' 8"
B.O. CEILING
SEE ELEVATIONS
B.O. LOFT
+12' 2"
B.O. TRUSS
+10' 8"
B.O. CEILING
+5' 6"
T.O. MTL STUD SUPPORT
SEE ELEVATIONS
B.O. SHELF
6"
3 5/8" 20ga.
METAL STUD @
16" O.C., TYP.
5/8" MOISTURE
RESISTANT GYP.
BD., TYPICAL
WALK IN
COOLER/FREEZER
WALL
#10 SHEET METAL
SCREW X 3/4"" LONG
@ 8" O.C.
3 5/8" 20ga TRACK W/#10
SHEET METAL SCREW X
3/4" LONG PER
CONNECTION BOTH SIDES
TYP.
1/2" MOISTURE
RESISTANT GYP. BD.
SCREWED IN WITH
STAGGERED JOINTS &
LEVEL 5 TAPING FINISH
3 5/8" X 20 GAGE STEEL
STUDS AT 4' 0.C. WITH
2#10 SCREWS INTO SLIP
TRACK, ATTACH STUD TO
TOP CHORD WITH
SFC2.25 SIMPSON
CONNECTOR USING SDS
SCREWS INTO WOOD
TRUSSES
ROOF STRUCTURE
CONT. SLIP TRACK
SFC CLIP
ROOF FRAMING,SEE
SIP SHEETS
LINE OF
SUSPENDED A.C.T.
CEILING
WALK IN COOLER/
FREEZER WALL
1/4" GYP. BD. SCREWED IN WITH
STAGGERED JOINTS AND LEVEL 5
TAPING FINISH
3 5/8" 20 GA TRACK W/ #10
SHEET METAL SCREW x 3/4"
LONG PER CONNECTION
BOTH SIDES TYP.
3 5/8" 20 GA MTL TRACK
5/8" MOISTURE RESISTANT GYP.
BD. TYPICAL
11
A9.2
______
11
A9.2
______
11
A9.2
______
TYP
8" MAX
TY
P
8"
M
A
X
MA
I
N
R
U
N
N
E
R
S
2'
0
"
O
.
C
.
CROSS "T" MEMBERS
2' 0" O.C.
GENERAL NOTES:
1. ENDS OF MAIN BEAMS AND CROSS
TEES MUST BE TIED TOGETHER TO
PREVENT THEIR SPREADING.
2. INSTALL CLG GRID USING #12 GA WIRE
HANGERS @ 4 FT MAX O.C. & 8" MAX FROM
PERIMETER WALL.
3. INTERMEDIATE DUTY GRID SYSTEM
REQUIRED.
4. CEILING MUST HAVE OVERSIZED TRIM
RINGS FOR SPRINKLERS AND OTHER
PENETRATIONS. PROVIDE 3/8" MIN CLEAR
ON ALL SIDES.
5. LIGHT FIXTURES (ALL TYPES) TO BE
MECHANICALLY ATTACHED TO GRID PER
NEC 410 16 (TWO 12 GA WIRES PER
FIXTURE UNLESS INDEPENDENTLY
SUPPORTED).
AIR TERMINALS SUPPORT REQUIREMENTS:
· <20 LBS POSITIVELY ATTACHED TO GRID
· 20 TO 56 LBS POSITIVELY ATTACHED TO
GRID AND TWO 12 GA WIRES TO STRUCTURE
(MAY BE SLACK)
· >56 LBS SUPPORTED DIRECTLY TO
STRUCTURE BY APPROVED HANGERS
12 GA HANGER WIRE
STABILIZER BAR
MIN CLR
3/8"
AT PERIMETER
8" MAX ℄
1
1
/
2
"
M
A
X
1
9
±
1
0
ANGLE BRACKET OR CLIP. ATTACH
PER MANUFACTURER
RECOMMENDATIONS.
12 GA VERTICAL SUPPORT WIRE @
4' 0" O.C. EA. WAY. AND MAX 8" FROM
ALL EDGES. WIRE MUST NOT EXCEED
A 1:6 SLOPE (±10)
MINIMUM OF 3 RIGHT TURNS AT ALL
WIRES
INTERMEDIATE DUTY SUSPENDED
GRID SYSTEM
MAIN RUNNER @ 2' 0" O.C.
INTERMEDIATE DUTY SUSPENDED GRID
SYSTEM CROSS "T" MEMBER @ 2' 0" OR
4' 0" O.C. (REFER TO SPECIFIC CEILING
TYPE)
ACOUSTICAL CEILING TILES
STABILIIZER BAR
7/8" MIN. WALL MOLDING
WALL OR SOFFIT FRAMING AND FINISHES.
REFER TO SPECIFIC DETAILS.
NOTE:
FASTENING TO STRUCTURE ABOVE TO
COMPLY WITH LOCAL BUILDING
DEPARTMENT REQUIREMENTS, IF
APPLICABLE.
CONFORM TO BASIC MINIMUM
REQUIREMENTS ESTABLISHED IN
ASTM C636 & ASTM E 580.
REFER TO DETAIL 10/A9.2 FOR CEILING
LAYOUT REQUIREMENTS.
6"
6"
5/8" GYP. BD.
TRUSS, SEE
STRUCT.
3 5/8" STUDS X 20
GA. AT 16" O.C.
SIP ROOF PANEL
TRUSS TOP CHORD
3 5/8" x 18 GA.
METAL BLKG. AT 16"
O.C.
LINE OF
SUSPENDED A.C.T.
CEILING
3 5/8" x 16 GA.
ROLLED METAL
TRACK. TYP.
SUSPENDED ACOUSTICAL
CEILING TILE, SEE RCP
SOFFIT CONNECTION TO
TRUSS FRAMING,
SEE STRU. DWGS.
3 5/8" X 20 GA.
METAL SOFFIT AT 16"
O.C.EXT. WALL, SEE SIP VENDOR
SHEETS
ANGLE BREAK METAL
TO CLOSE GAP,
PAINT TO MATCH
FRP FINISH
1/4" GYP. BD.
SCREWED IN WITH
STAGGERED JOINTS
& LEVEL 5 TAPING
FINISH
FRP PANELING
WHERE APPLICABLE
SIP WALL PANEL. SEE
FINISH SHEDULE
WALK IN COOLER/FREEZER
WALL
SCREW TO FASTEN
CAULK ON BOTH
EDGES
SCREW TO FASTEN
EXT. WALL, SEE
SIP SHEETS
2#10 TEK SCREW
@ 8" O.C. TYP.
3 5/8" x 16 G.A.
ROLLED METAL TRACK. TYP.3 5/8" X 20 GA. METAL
SOFFIT AT 16" O.C. W/ 5/8"
GYP. BD. ONE SIDE
TRUSS, SEE
SIP SHEETS
SUSPENDED
ACCOUSTICAL CEILING
TILE, SEE RCP 3 5/8" STUDS X
20 GA. AT
16"O.C.
SIP ROOF
PANEL
TRUSS TOP CHORD
SOFFIT CONNECTION
TO TRUSS FRAMING
SEE STRU. DWGS.
6"
REFER TO RCP
6"
SOFFIT CONNECTION
TO TRUSS FRAMING,
SEE STRU. DWGS.
TRUSS, SEE
SIP SHEETS
SIP ROOF PANEL
TRUSS TOP
CHORD
WALL TYPE PER
PLAN
MOUNTED
LED LIGHT
SUSPENDED
ACOUSTICAL CEILING
TILE, SEE RCP
WALL
CONNECTION PER
DETAIL 8/A9.1
WALL MOUNTED SOFFIT
SYSTEM
PROVIDED BY DECOR
VENDOR
HINGED PANEL
OPENING BY DECOR
VENDOR
1/2" PLYWOOD SHEATHING
W/ 10d AT 6" O.C.
INSTALL 1/2"∅ALL THREAD RODS
@ ENDS, CORNERS AND WHERE
SPAN EXCEEDS 5' 0"
COUNTERSUNK WASHER (2"∅)
& BOLT (MIN. 3 THREADS)
5/8" GYP. BD. W/ FRP FINISH
CORNER BEAD
1 1/4" ALUM. ANGLE RECESS TO
PLYWOOD
FRP (WHERE OCCURS)
2"X4" NAILERS W/ 2 16d
PER STUD
2' 0"
2 2"X4" NAIL W/ 10d @ 6" O.C.
TRUSS, SEE SIP SHEETS
CEILING PER PLANS
TRUSS TOP CHORD
SIP ROOF PANEL
3"X6" BLOCKING W/ SIMPSON
A35 EA. END STAGGER EA. SIDE
OF TRUSS. SEE SIP SHEETS
L 2 1/2" X 2 1/2" X 4" LONG
OF 1/4" THK. W/ 2 1/4"∅LAG
SCREWS AT 2" O.C., 2" EMBED
(EQUALLY SPACED)
1/2"∅ALL THREAD RODS,
PROVIDE EMT TO COVER
THREADS
2"X4" @ 16" O.C. W/
SIMP "LU" HANGER EA.
END
SIP WALL PANEL
2"X4" NAILER W/ 10d @
6" O.C. (2 @ 6" O.C.)
2x DOUBLE TOP
PLATE PER SIP
FRP FINISH
FRP FINISH
MI
N
.
G
Y
P
6"
GC TO COORDINATE WITH CK CM FOR
OPTIONAL LOFT DETAIL 12/A9.2 FOR
PROJECT USE
(2) 8" SIP THREAD POINT
SCREW @ 6" O.C.
MOP SINK
CAULK INTERSECTION OF MOP BASIN AND
FRP (ALL THREE SIDES)
362S137 43 METAL STUDS AT 12" O.C.
20 GA. CONT. BLOCK W/ #10x3/4" SELF
TAPPING SCREWS TO EA. STUD.
PEBBLE SURFACE MARLITE FRP
PANELING, TO BOTTOM OF WATER
HEATER SHELF, P 100 WHITE, OR EQUAL.
5/8" GYP. BD. EACH SIDE, TYP.
PROVIDE W.R. GYP. BD. AT INTERIOR
OF WALL
362S137 43 METAL STUD @ EACH END
AND 12" O.C., TYP., ATTACH TO STUD W/
4 #12 SCREWS, TYP. EA. END.
2" 24 GA STAINLESS STEEL RETURN
2"2"
24 GA. STAINLESS STEEL OVER 3/4" C.D.X.
PLYWOOD TOP AND BOTTOM OF PLATFORM.
SCREW PLYWOOD TO STUD W/ 1/4"x2 1/2"
TEX SCREW AT 6" O.C.
DRAIN PAN. SEE PLUMBING
20 GA. BLOCK, BEND AS REQUIRED AND
ATTACH TO JOIST W/ 2 #12 EA. END.
ELECTRIC WATER HEATER, SEE
PLUMBING PLANS, 550 LBS
CEILING PER PLANS
2"x20 GA. STRAP WATER HEATER TO METAL
STUD OR BLOCKING W/ 3 #10 SCREWS OR
PER MFR'S SPECIFICATIONS, TYP.
NICHIHA
FIBER
CEMENT PANEL
1 LAYER OF #15
ASPHALT FELT WATER
RESISTIVE BARRIER
OVER EXTERIOR GRADE
SIP WALL PANEL
(2) 8" SIP THREAD POINT
SCREW @ 6" O.C.
SIP WALL PANEL OR METAL
STUD WALL DEPENDING ON
LOCATION
FRP (WHERE OCCURS)
(2) 8" SIP THREAD POINT SCREW
@ 6" O.C.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A9.2
PROJECT NUMBER: 24212
INTERIOR
ARCHITECTURAL
DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1 1/2" = 1' 0"
5VALANCE AT WALK IN EQUIPMENT
3" = 1' 0"
6COOLER SIDE CLOSURE DETAIL
1/8" = 1' 0"
10ACT CEILING LAYOUT
3" = 1' 0"
11ACOUSTICAL CEILING TILE
1 1/2" = 1' 0"
9SOFFIT DETAIL
3" = 1' 0"
3BREAK METAL AT COOLER
1 1/2" = 1' 0"
8SOFFIT DETAIL
1 1/2" = 1' 0"
7SIGNAGE VALANCE @ CEILING
1 1/2" = 1' 0"
4STORAGE LOFT DETAIL
1" = 1' 0"
1SECTION THRU WATER HEATER/MOP SINK
1 1/2" = 1' 0"
12STORAGE LOFT DETAIL
CONTINUOUS 26 GA. 8" HIGH GSM
FLASHING. BOTTOM EDGE TO EXTEND MIN.
4" BELOW FLOOR SLAB. SET IN FULL BED
OF MASTIC. PAINT EXPOSED SURFACE TO
MATCH FIBER CEMENT COLOR
SEE FINISH PLANS
SILL GASKET
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL PANEL
NICHIHA FIBER CEMENT PANEL
SEE STRUCT.
CONCRETE FOOTING,
SEE STRUCTURAL
DRAWINGS FOR
SPECIFIC
INFORMATION
ANCHOR BOLT, SEE
STRUCT.
SACKED EXPOSED FOUNDATION,
PAINT TO MATCH FIBER CEMENT
COLOR, TYP.
NICHIHA STARTER FLASHING
NICHIHA HORIZONTAL STARTER TRACK
1/4" CLEARANCE BETWEENEDGE OF
PANEL AND FLASHING
3"
M
I
N
.
R 10 EDGE OF SLAB
INSULATION
1'
6
"
FA
C
E
O
F
P
A
N
E
L
SEE SHEET A1.3 PLAN FOR DIMENSION (F.O.S.)
2 X 6 FRAMING
PER SIP VENDOR
WALL FINISH PER
PLAN AND FINISH
SCHEDULE
SIP WALL PANELS
FACE OF PANEL
TO ALIGN WITH FDN.
SLAB
SIP WALL PANEL
2 X CORNER FRAMING
PER SIP VENDOR
SINGLE FLANGE
SEALANT
BACKER, TYP.
SINGLE FLANGE
SEALANT
BACKER, TYP.
NICHIHA FIBER
CEMENT PANEL
1 LAYER OF #15 ASPHALT
FELT WATER RESISTIVE
BARRIER OVER SIP WALL
PANEL
ULTIMATE CLIP
FACE OF PANEL TO
ALIGN WITH STEM
WALL FDN. TYP.
WALL FINISH PER
PLAN AND FINISH
SCHEDULE
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER OVER
SIP WALL PANEL
FIBER CEMENT CLIP
KURASTONE LEDGESTONE
SIP WALL PANELS
2 X CORNER
FRAMING
PER SIP VENDOR
1' 1 1/2"
WALL FINISH PER
PLAN AND FINISH
SCHEDULE
1 LAYER OF #15 ASPHALT FELT
WATER RESISTIVE BARRIER OVER
SIP WALL PANEL
FIBER CEMENT CLIP
KURASTONE LEDGESTONE
SIP WALL PANELS
2 X CORNER
FRAMING
PER SIP VENDOR
CONCRETE FOOTING, SEE
STRUCTURAL DRAWINGS FOR
SPECIFIC INFORMATION
CONTINUOUS 26 GA. 8" HIGH GSM FLASHING.
BOTTOM EDGE TO EXTEND MIN. 4" BELOW
FLOOR SLAB. SET IN FULL BED OF MASTIC.
PAINT EXPOSED SURFACE TO MATCH FIBER
CEMENT COLOR
SEE CIVIL AND
LANDSCAPE
SIP WALL PANEL.
SEE SIP SHEETS
1 LAYER OF #15 ASPHALT FELT WATER
RESISTIVE BARRIER OVER SIP WALL
PANEL
KURASTONE CLIP
KURASTONE PIECE
NICHIHA STARTER FLASHING
SILL GASKET
FINISH WHERE APPLIES. SEE
FINISH PLAN AND SCHEDULE
MIN. DISTANCE TO HARD SURFACE
WHERE OCCURS
ANCHOR BOLT, SEE STRUCT.
SACKED EXPOSED FOUNDATION, PAINT
TO MATCH FIBER CEMENT COLOR, TYP.
NICHIHA HORIZONTAL STARTER TRACK
FASTNER SPACING 12" O.C.
1/4" CLEARANCE BETWEEN EDGE OF
PANEL AND FLASHING
3"
7"
SEE STRUCT.
4"
8"
1 LAYER OF #15 ASPHALT FELT WATER RESISTIVE
BARRIER OVER SIP WALL PANEL
KURASTONE CLIP
KURASTONE PIECE
NICHIHA FIBER CEMENT PANEL
METAL FLASHING, SW TOTALLY TAN (MISSING PER CB 12
AND 12 R1)
NICHIHA STARTER TRACK
1/4" CLEARANCE BETWEEN EDGE OF PANEL AND FLASHING
FINISH WHERE APPLIES. SEE
FINISH PLAN AND SCHEDULE
SIP WALL PANEL.
SEE SIP SHEETS
NOTE:
1. METAL FLASHING IN ALL AREAS
TO BE PROVIDED AND INSTALLED
BY G.C.
2. INSTALL NICHIHA SILL FIRST
THEN WORK LEDGESTONE UP TO
BOTTOM OF SILL.
UPSIDE DOWN ULTIMATE HORIZONTAL STARTER TRACK
(INSTALLED FIRST)
KURASTONE SILL CHISELED ON UPSIDE DOWN SILL
CHISELED CLIPS ON 5MM SPACER
SILL CHISELED CLIP
KURASTONE CLIP ATTACHED
VERTICALLY
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
A9.3
PROJECT NUMBER: 24212
PILASTER DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
3" = 1' 0"
1BASE SILL DETAIL
1 1/2" = 1' 0"
3PILASTER DETAIL
1 1/2" = 1' 0"
2FRONT CORNER DETAIL
1 1/2" = 1' 0"
4CORNER DETAIL (KURASTONE)
3" = 1' 0"
5BASE SILL DETAIL (KURASTONE)
1 1/2" = 1' 0"
6TRANSITION DETAIL
TYP.
CA 03
TYP.
CA 03
TYP.
CA 04
TYP.
CA 01
TYP.
CA 03
TYP.
CA 03
TYP.
CA 02
TYP.
CA 02
TYP.
CA 02
TYP.
CA 02
CA 05CA 05
_______
CA 2
1
_______
CA 2
2
_______
CA 2
3_______
CA 2
4
12' 0"
TYP.
28' 0"
TYP.
28' 0"
TYP.
28' 0"
TYP.
28' 0"
TYP.
28' 0" 28' 0" 12' 0"
C STORE SIDE
STREET SIDE
STREET SIDE
14 13 12 11 10 9 8 7 6 5 4 3 2 1
(28' OPTIMUM)
(25' MINIMUM)
24
'
0
"
192' 0"
CD 01
TYP.
CA 01
CD 01
TYP.
CA 01
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
CA 1
PROJECT NUMBER: 24212
FUEL CANOPY PLAN
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 985971/8" = 1' 0"
1FUEL CANOPY PLAN
NUMBER DESCRIPTION
CA 01 MULTI PRODUCT DISPENSER, SEE FUEL DRAWINGS
CA 02 CONCRETE PAVING. SEE CIVIL SHEET & STRUCT. DRAWINGS
CA 03 36" HIGH, 6" BOLLARD, QTY. 2 AT EACH END OF DISPENSER. REFER TO FUEL
DRAWINGS
CA 04 STEEL CANOPY COLUMN. SEE FUEL CANOPY STRUCTURAL DRAWINGS
CA 05 LINE OF CANOPY ABOVE
CD 01 MASTER DISPENSER, SEE FUEL DRAWINGS
KEYNOTES X
CB 01 CB 01 CB 01
CB 02
CB 03
CB 04
CB 03
C B A
D
E
F
T.O. FASCIA
15' 6"
T.O. FASCIA
18' 6"
CB 01 CB 01 CB 01
CB 02
CB 05
CB 04
CB 03
CB 06CB 06 C B A
E
F
A B
T.O. FASCIA
15' 6"
T.O. FASCIA
18' 6"
CB 06 CB 06 CB 01 CB 01
CB 01
CB 03
CB 03
CB 04
CB 05
A B B A
C
F
D
E
T.O. FASCIA
15' 6"
T.O. FASCIA
18' 6"
CB 04 E
CB 01 CB 01 CB 01
CB 03
CB 02
CB 03
CB 05
CB 04
A B C
F
D
E
T.O. FASCIA
15' 6"
T.O. FASCIA
18' 6"
CIRCLE K RED #PMS 485
CIRCLE K WHITE
CIRCLE K ORANGE #PMS 144
SHERWIN WILLIAMS SW6236 GRAYS HARBOR
PVC BOLLARD SLEEVE DARK GRAY
RAL9016 SHELL WARM WHITE
A
B
C
D
E
F
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
CA 2
PROJECT NUMBER: 24212
FUEL CANOPY
ELEVATIONS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1/8" = 1' 0"
1REAR ELEVATION (NORTH)
1/8" = 1' 0"
2FRONT ELEVATION (SOUTH)
1/8" = 1' 0"
3SIDE ELEVATION (EAST)
1/8" = 1' 0"
4SIDE ELEVATION (WEST)
NOTES:
1. COLORS SHOWN ON THESE ELEVATIONS ARE FOR ILLUSTRATION PURPOSES ONLY. FOR ACTUAL
COLORS, REFER TO MANUFACTURER'S SAMPLES.
2. THE FASCIA PANELS ARE PRE FINISHED BY SIGNAGE VENDOR
3. ALL SIGNS REQUIRE A SEPARATE SUBMITTAL.
4. ALL LIGHTING ON CANOPY TO BE FLUSH MOUNTED WITH FASCIA
KEY NOTES
FINISH SCHEDULE
X
X
NUMBER DESCRIPTION
CB 01 ACM PANEL "TEX COTE
CB 02 COLUMN FLAGS BY SIGNAGE VENDOR
CB 03 STEEL COLUMN WITH PAINT FINISH
CB 04 6"0 BOLLARD, 36" HIGH
CB 05 FUEL PUMP
CB 06 INTERNALLY ILLUMINATED SIGN UNDER SEPARATE PERMIT
3"∅PVC DRAIN,
BY FUEL CANOPY VENDOR
LC OF COLUMN
NOTE:
SEE STRUCTURAL FUEL CANOPY
SHEETS FOR SPECIFIC INFO. AND
CANOPY ELEVATIONS FOR FINISH
SCHEDULE.
STEEL COLUMN, SEE ELEVATIONS AND
STRUCT. FUEL CANOPY DWGS.
STEEL COLUMN, PAINT W/ STUCCOFLEX,
SEE EXT. ELEVATIONS FOR COLOR
2
CA 3
______
CONCRETE FOOTING, SEE
FUEL CANOPY STRUCTURAL
DRAWINGS FOR SPECIFIC
INFORMATION
TOP OF DRIVE
HEADER
DECK, SEE STRUCT.
FUEL CANOPY DWGS.
STEEL COLUMN, PAINT W/
STUCCOFLEX, SEE EXT.
ELEVATIONS FOR COLOR
CONCRETE, SEE CIVIL
NOTE:
SEE STRUCTURAL FUEL CANOPY DWGS
FOR SPECIFIC INFO. AND CANOPY
ELEVS FOR FINISH SCHEDULE.
STEEL COLUMN,
SEE STRUCT. FUEL CANOPY DWGS.
11
CA 3
______
CANOPY DWGS.
SEE STRUCT.
FUEL
GENERAL NOTES
1. SEE STRUCTURAL FUEL CANOPY DWGS FOR MORE INFORMATION.
2. SEE EXTERIOR CANOPY ELEVATIONS FOR FINISH.
REVISIONS
ISSUE DATE
COPYRIGHT NOTICE
This drawings is the property of the above
referenced Professional and is not to be
used for any purpose other than the specific
project and site named herein, and cannot be
reproduced in any manner without the
express written permission from the
professional
CIRCLE K STORE INC.
PROFESSIONAL SEAL
PROJECT NAME
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROTOCYCLE # R3.4.1 05/16/23
OTP 11/12/24
YELM, WA
SS
PC
RM
PC
CA 3
PROJECT NUMBER: 24212
FUEL CANOPY
COLUMN DETAILS
CIRCLE K
STORES, INC.
NWC YELM AV & KILLION RD
YELM, WA 98597
1" = 1' 0"
1FUEL CANOPY COLUMN PLAN TYP.
1" = 1' 0"
2COLUMN SECTION @FUEL CANOPY TYP.
05/18/22
06/20/22