Circle K - Yelm (Yelm & Killion), WA - Electrical OTPREVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E0.0 PROJECT NUMBER: 24212 ELECTRICAL COVER SHEET AND LEGEND CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 2023 NATIONAL ELECTRICAL CODE W/ WASHINGTON STATE AMENDMENTS 2021 WASHINGTON STATE BUILDING CODE 2021 WASHINGTON STATE FUEL GAS CODE 2021 WASHINGTON STATE FIRE CODE 2021 WASHINGTON STATE ENERGY CODE CODE COMPLIANCE INFORMATION SD J OS2S OSS 3S DS MS KS S STANDARD 20A, SINGLE PHASE SPST TOGGLE SWITCH SMOKE DETECTOR / DUCT SMOKE DETECTOR HORN / STROBE, CANDELA AS INDICATED, COORDINATE WITH FIRE ALARM PLANS ABBREVIATIONS SURFACE MOUNTED PANELBOARD, REFERENCE PANEL SCHEDULE FOR RATINGS AND COMPONENTS FLUSH MOUNTED PANELBOARD, REFERENCE PANEL SCHEDULE FOR RATINGS AND COMPONENTS TELEPHONE OUTLET WITH (2) RJ45 PORTS U.O.N., PROVIDE 3/4"C TO ACCESSIBLE CEILING SPACE OR AS OTHERWISE INDICATED DISCONNECT SWITCH, AMPS, POLES AND FUSE SIZE AS SHO WN (FUSE SIZE CALLED OUT IF REQUIRED) STANDARD 20A, 120V 1PH GROUNDING TYPE SIMPLEX RECEPTACLE JUNCTION BOX. SIZED BY THE CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND / OR CONDUCTORS PASSING THROUGH. (WALL MOUNTED/CEILING MOUNTED) KEYED SWITCH DIMMER SWITCH, SINGLE PHASE SLIDING TYPE SWITCH. LUTRON "NOVA-T" SERIES OR APPROVED EQUAL. PROVIDE SEPARATE NEUTRAL FOR EACH DIMMER CIRCUIT. MANUAL MOTOR SWITCH 3-WAY SWITCH LIGHT FIXTURE, NIGHT LIGHT LIGHT FIXTURE (WALL MOUNTED/CEILING MOUNTED) LIGHT FIXTURE (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) SYMBOL DESCRIPTION SINGLE POLE OCCUPANCY SENSOR SWITCH DOUBLE POLE OCCUPANCY SENSOR SWITCH EXIT SIGN, WITHOUT OR WITH INTEGRATED EMERGENCY LIGHTING (WALL MOUNTED/CEILING MOUNTED) EMERGENCY LIGHT (WALL MOUNTED/CEILING MOUNTED) a, b, c LOWER CASE LETTERS INDICATE SWITCHING CONFIGURATION AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE C CONDUIT CCT CIRCUIT CF CEILING FAN CW CASH WRAP EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EM EMERGENCY LIGHTING FIXTURE ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER G GROUND GFEP GROUND FAULT EQUIPMENT PROTECTION GFI GROUND FAULT CIRCUIT INTERRUPTER IG ISOLATED GROUND ELECTRICAL SYMBOLS LEGEND LCU LIGHTING CONTROL UNIT NL NIGHT LIGHT NTS NOT TO SCALE REC REFRIGERATION ELECTRICAL CONTRACTOR RC REFRIGERATION CONTRACTOR RH RADIANT HEATER SC SECURITY CAMERA TR TAMPER RESISTANT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE WH WATER HEATER WP WEATHER PROOF WR WEATHER RESISTANT INV EMERGENCY POWER INVERTER PE CEILING MOUNTED LINE VOLTAGE PHOTOCELL SENSOR, LEVITON "PCCSD-W" OR EQUAL. CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR, LEVITO N ODC05-MDW OR EQUAL. STANDARD 20A, 120V 1PH GROUNDING TYPE DUPLEX RECEPTACLE STANDARD 20A, 120V 1PH GROUNDING TYPE QUADRUPLEX RECEPTACLE STANDARD 20A, 120V 1PH GROUNDING "GROUND FAULT INTERRUPTER" GFI RECEPTACLE STANDARD 20A, 120V 1PH ISOLATED GROUND TYPE DUPLEX RECEPTACLE, ORANGE IN COLOR STANDARD 20A, 120V 1PH GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED IN FLUSH FLOOR OUTLET BOX STANDARD 20A, 120V 1PH GROUNDING TYPE QUADRUPLEX RECEPTACLE MOUNTED IN FLUSH FLOOR OUTLET BOX SPECIAL RECEPTACLE - VERIFY NEMA CONFIGURATION WITH INSTALLED EQUIPMENT MANUFACTURER REQUIREMENTS. CEILING MOUNTED RECEPTACLE, STANDARD 20A, 120V 1PH GROUNDING TYPE DUPLEX RECEPTACLE SD 110cd DATA OUTLET WITH (2) RJ45 PORTS U.O.N., PROVIDE 3/4"C TO ACCESSIBLE CEILING SPACE OR AS OTHERWISE INDICATED COMBINATION TELEPHONE / DATA OUTLET WITH (4) RJ45 PORTS U.O.N., PROVIDE (2) 3/4"C TO ACCESSIBLE CEILING SPACE OR AS OTHERWISE INDICATED SECURITY CAMERA BY OTHERS. ALL LIGHTING FIXTURES ARE SUPPLIED BY CIRCLE K, INSTALLED BY THE ELECTRICAL CONTRACTOR LIGHTING FIXTURE SCHEDULE TYPE ITEM TYPE DESCRIPTION MANUFACTURER MODEL LAMP WATTS VOLTAGE COMMENTS COUNT A INTERIOR LIGHTING 2'x4' H.E. TROFFER CREE RLA-FLX24-50L-940-CRV-10V10-UNV LED 41 W 120 V 43 AE INTERIOR LIGHTING 2'x4' H.E. TROFFER WITH BATTERY CREE RLA-FLX24-50L-940-CRV-10V10-UNV-EB LED 41 W 120 V WITH EMERGENCY BALLAST 11 B INTERIOR LIGHTING 6" RECESSED DOWNLIGHT CREE RLA-LR6X-18L-40K LED 21 W 120 V 25 C INTERIOR LIGHTING 2'x2' H.E. TROFFER CREE RLA-FLX22-40L-940-CRV-10V10-UNV LED 33 W 120 V 10 CE INTERIOR LIGHTING 2'x2' H.E. TROFFER WITH BATTERY CREE RLA-FLX22-40L-940-CRV-10V10-UNV-EB LED 33 W 120 V WITH EMERGENCY BALLAST 2 D INTERIOR LIGHTING 4' GASKETED WRAP AROUND CREE RLA-WS4-C-40L-LRA-40K-8-UL LED 30 W 120 V 4 DE INTERIOR LIGHTING 4' GASKETED WRAP AROUND WITH BATTERY CREE RLA-WS4-C-40L-LRA-40K-8-UL+ LIGHT ALARMS LALDR-14 LED 30 W 120 V 3 J INTERIOR LIGHTING 8' LED LINEAR FIXTURE CREE RLA -LS8-120L-950-R-UL-10V LED 92 W 120 V 5 JE INTERIOR LIGHTING 8' LED LINEAR FIXTURE WITH BATTERY CREE RLA -LS8-120L-950-R-UL-10V-EB1 LED 92 W 120 V 1 K INTERIOR LIGHTING 4' LED LINEAR FIXTURE CREE RLA-LS4-60L-950-R-UL-10V LED 44 W 120 V 4 A3B EXTERIOR SITE LIGHTING SINGLE MEDIUM EXTERIOR POLE FIXTURE LITHONIA RSX2 LED P2 50K R3 MVOLT SPA HS FAO LED 114 W 120 V 4 A4B EXTERIOR SITE LIGHTING SINGLE MEDIUM EXTERIOR POLE FIXTURE LITHONIA RSX2 LED P2 50K R4S MVOLT SPA HS FAO LED 114 W 120 V 8 INV EXTERIOR SITE LIGHTING EMERGENCY BATTERY BACKUP FOR EXT DOWNLIGHTS - 90 MIN DUAL-LITE LG125T1AO LED 21 W 120 V 1 L EXTERIOR SITE LIGHTING 6" RECESSED DOWNLIGHT LITHONIA LBR6 ALO2 20LM SWW1 (4000K) AR LSS MWD 90CRI WL LED 25 W 120 V VERIFY COLOR AND FINISH WITH ARCH/OWNER 11 WP EXTERIOR SITE LIGHTING EXT. WALL PACK ("EM" - INVERTER BACK-UP) LITHONIA ARC2 LED P5 50K MVOLT LED 51 W 120 V VERIFY COLOR AND FINISH WITH ARCH/OWNER 9 EM EMERGENCY LIGHTING LED EMERGENCY DUAL HEAD LIGHTALARMS RLA-LCA-2LED LED 12 W 120 V 4 EX EMERGENCY LIGHTING LED EXIT SIGN / EMERGENCY LIGHT COMBO LIGHTALARMS RLA-UQLXN500X-2LED LED 12 W 120 V 4 W EMERGENCY LIGHTING WET-LISTED EMERGENCY REMOTE DUAL HEAD LIGHTALARMS CAM-SD-XX LED 2 W 120 V (2) 1W HEADS GRAY FINISH 2 CAN1 CANOPY LIGHTING CANOPY LIGHT LITHONIA XPCNY LED ALO2-13L SWW2-50K FPCL MVOLT DWHXD M3 LED 91 W 208 V CANOPY LIGHT 14 CAN2 CANOPY LIGHTING CANOPY LIGHT LITHONIA XPCNY LED ALO2-13L SWW2-50K FTL MVOLT DWHXD M3 LED 89 W 208 V CANOPY LIGHT 14 OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST 1.SECTION 16010 -BASIC ELECTRICAL REQUIREMENTS A.THE WORK OF EACH OF THE ELECTRICAL SECTIONS INCLUDES FURNISHING AND INSTALLING THE MATERIAL, EQUIPMENT, AND SYSTEMS COMPLETE AS SPECIFIED AND/OR INDICATED ON THE DRAWINGS. THE ELECTRICAL INSTALLATIONS, WHEN FINISHED, SHALL BE COMPLETE AND COORDINATED, READY FOR SATISFACTORY SERVICE. B.THE WORK UNDER THIS CONTRACT SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE MUNICIPAL, STATE AND OTHER LOCAL CODES, THE 2023 EDITION OF THE NATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS AND THE 2010 ADA STANDARDS. C.THE CONTRACTOR SHALL MAKE APPLICATION AND PAY FOR ALL PERMITS, LICENSES AND INSPECTIONS AS REQUIRED UNDER THE ABOVE CODES. D.THE GENERAL ARRANGEMENT OF CONDUIT, WIRING AND EQUIPMENT SHALL BE AS IDENTIFIED ON THE CONTRACT DRAWINGS. THE CONTRACTOR SHALL CAREFULLY INVESTIGATE THE SITE, STRUCTURAL, AND FINISH CONDITIONS AFFECTING HIS WORK AND SHALL ARRANGE SUCH WORK ACCO RDINGLY, PROVIDING SUCH FITTINGS AND ACCESSORIES AS MAY BE REQUIRED TO MEET SUCH CONDITIONS. E.THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND SERVICES NECESSARY FOR AND REASONABLY INCIDENTAL TO THE COMPLETE INSTALLATION OF THE ELECTRICAL WORK AND RELATED SYSTEMS AS INDICATED ON THE DRAWINGS OR AS NECESSARY TO PROVIDE A COMPLETE SYSTEM. F.THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY WIRING, LIGHTING AND CONSTRUCTION POWER FOR ALL TRADES AS REQUIRED TO COMPLETE THE PROJECT. G.ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND COMPLETED IN A FIRST CLASS WORKMANLIKE MANNER. ALL MATERIALS SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE KINDS. ALL EQUIPMENT AND SYSTEMS SHALL BE APPROVED BY UL OR SIMILAR NATIONALLY ACCEPTED TESTING AGENCY SUCH AS ETL TESTING LABORATORIES. H.THE CONTRACTOR SHALL VISIT THE SITE AND OBSERVE THE CONDITIONS UNDER WHICH THE WORK SHALL BE COMPLETED. NO ALLOWANCE WILL BE MADE SUBSEQUENTLY IN THIS CONTRACT FOR ANY ERROR OR NEGLIGENCE IN THE CONTRACTOR'S PART. I.THE CONTRACTOR SHALL SUBMIT DETAILED DIMENSIONED SHOP DRAWINGS, TOGETHER WITH WIRING DIAGRAMS, SPECIFICATIONS, OPERATING DATA, AND/OR CATALOG CUTS FOR ALL EQUIPMENT. J.A THOROUGH TEST SHALL BE MADE PRIOR TO ENERGIZING THE SYSTEM TO DEMONSTRATE THAT THE SYSTEM IS ENTIRELY FREE FROM GROUND FAULTS, SHORT CIRCUITS, AND OPEN CIRCUITS; THAT THE RESISTANCE TO GROUND OF ALL NON-GROUNDED CIRCUITS, BEFORE AND AFTER CONNECTION OF EQUIPMENT MEETS THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND IEEE STANDARDS/RECOMMENDATIONS. K.IDENTIFY ALL MOTOR STARTERS, SWITCHES, CONTROLS, PANELBOARDS, SWITCHBOARDS, TERMINAL BOARDS, CONTROL CENTERS AND OTHER EQUIPMENT. IDENTIFICATION PLATES SHALL BE LAMINATED PLASTIC, BLACK AND WHITE ENGRAVED LETTERS. LETTERING FOR CONTROL CENTERS, CONTROL PANELS, METERING AND INSTRUMENT PANELS SHALL BE 3/8" HIGH. L.THE MATERIAL AND WORKMANSHIP OF ALL PARTS OF THE ELECTRICAL INSTALLATION SPECIFIED HEREIN SHALL BE GUARANTEED UNCONDITIONALLY FOR A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL CERTIFICATE OF OCCUPANCY OR GRAND OPENING, WHICH EVER COMES FIRST. M.UPON COMPLETION OF THE ELECTRICAL INSTALLATION, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE SET OF SCANNED DIGITAL PRINTS OF ELECTRICAL CONTRACT DRAWINGS WHICH SHALL BE LEGIBLY MARKED IN RED TO SHOW ALL ADDITIONS, CHANGES AND DEPARTURES OF THE INSTALLATION AS COMPARED WITH THE ORIGINAL DESIGN. THEY SHALL BE SUITABLE FOR USE IN PREPARATION OF RECORD DRAWINGS. N.THE CONTRACTOR SHALL PREPARE A RECORD AND INFORMATION MANUAL. THE MANUAL SHALL BE SCANNED INTO A DIGITAL FORMAT AND FORWARDED TO CIRCLE K CONSTRUCTION. PROVIDE THE FOLLOWING DATA IN THE RECORD AND INFORMATION MANUAL: 1)CUT SHEETS OF ALL EQUIPMENT WITH TECHNICAL SPECIFICATIONS. 2)OPERATION AND MAINTENANCE PROCEDURES. 3)SERVICING INSTRUCTIONS. 4)COPIES OF PANELBOARD DIRECTORIES. 5)COPIES OF WARRANTIES. 6)LIST OF LAMPS SHOWING QUANTITY, TYPE, WATTAGE, MANUFACTURER, CATALOG NUMBER, ETC., FOR EACH FIXTURE TYPE. 7)COPIES OF TEST REPORTS. O.EXACT LOCATIONS OF OUTLETS SHALL BE COORDINATED WITH DOOR SWINGS AND VARIOUS PROTRUSIONS. MOUNTING HEIGHTS OF THE VARIOUS ELECTRICAL DEVICES SHALL BE AS FOLLOWS: SWITCHES 46" AFF TO CENTER OF BOX RECEPTACLES 20" AFF TO CENTER OF BOX TELEPHONE OUTLETS 20" AFF TO CENTER OF BOX EXIT LIGHTS CENTERED BETWEEN CEILING AND TOP OF DOOR (UP TO 1'-0" ABOVE DOOR), SURFACE OR CEILING MOUNTED AS SHOWN DISCONNECTING SWITCHES 52" AFF TO CENTER OF SWITCH P.PROVIDE A DISCONNECT SWITCH FOR EACH MOTOR AS SHOWN ON THE DRAWINGS SIZED AS REQUIRED TO MEET THE NEC AND PROVIDE ALL WIRING CONNECTIONS FROM SOURCE. PROVIDE REQUIRED VOLTAGE. Q.SEAL ALL CONDUIT PENETRATIONS THRU RATED WALLS AND FLOORS TO MAINTAIN FIRE INTEGRITY. REFER TO ARCHITECTURAL DRAWING FOR FIRE WALL LOCATIONS. R.ELECTRICAL CONTRACTOR SHALL VERIFY ALL VOLTAGES OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. 2.SECTION 16050 -BASIC ELECTRICAL MATERIALS AND METHODS A.INSTALL ALL WIRING CONDUIT EXCEPT AS OTHERWISE INDICATED. MINIMUM CONDUIT SIZE SHALL BE 3/4". ALL CONDUIT EMBEDDED IN CONCRETE SHALL BE 3/4" MINIMUM. INSTALL ALL CONDUIT CONCEALED UNLESS ON UNFINISHED WALLS, ON UNFURRED CEILINGS OR MECHANICAL EQUIPMENT SPACES. PROVIDE CONDUIT AS FOLLOWS: 1)RIGID STEEL CONDUIT FOR WORK EXPOSED TO WEATHER OR EMBEDDED IN CONCRETE OR MASONRY. 2)GALVANIZED ELECTRICAL METALLIC TUBING (EMT) FOR INTERIOR EXPOSED WORK, CONCEALED WORK ABOVE SUSPENDED CEILINGS, AND WITHIN INTERIOR PARTITIONS OR NON-MASONRY WALLS. 3)FLEXIBLE METAL CONDUIT IN SHORT LENGTHS (6' MAXIMUM) FOR THE CONNECTION OF RECESSED LIGHTING FIXTURES AND MOTORS. 4)LIQUID TIGHT FLEXIBLE METAL CONDUIT WHEREVER MOISTURE MAY BE PRESENT AND MOTORS IN MECHANICAL EQUIPMENT SPACES. 5)POLYVINYLCHLORIDE (PVC) SCHEDULE 40 AND 80 CONDUIT WITH GROUND CONDUCTOR FOR UNDERGROUND OUTSIDE OF BUILDING (SITE) INSTALLATION AS PERMITTED BY NEC ARTICLE 352. B.INSTALL CONDUITS PARALLEL AND PERPENDICULAR TO WALLS AND INTERIOR SURFACES. CLEAN AND PLUG AND PROVIDE A PULL LINE IN EACH CONDUIT LEFT EMPTY. USE MANUFACTURED ELBOWS AND SCREW JOINTED CONDUIT FITTINGS. USE CAPPED BUSHINGS OR "PUSH PENNY" PLUGS. ALL FITTINGS SHALL BE STEEL OR MALLEABLE IRON. ALL EMT FITTINGS SHALL BE COMPRESSION TYPE. C.ALL OUTLET, SWITCH AND JUNCTION BOXES, SHALL BE STAINLESS STEEL BY STEEL CITY, RACO, APPLETON, VALEN, OR EQUIVALENT. OUTLET BOXES IN CONCRETE CONSTRUCTION SHALL BE OCTAGONAL. NO "THRU-WALL" BOXES SHALL BE USED IN PARTITIONS. ALL BOXES SHALL BE FURNISHED WITH APPROPRIATE COVERS. D.JUNCTION AND PULL BOXES SHALL BE FURNISHED AND INSTALLED AS INDICATED OR WHERE REQUIRED TO FACILITATE PULLING OF WIRES OR CABLES. BOXES FOR EXTERIOR WORK SHALL BE CAST ALUMINUM OR GALVANIZED CAST IRON TYPE WITH THREADED HUBS, UNLESS OTHERWISE DIRECTED. GASKETED COVER PLATES SHALL BE FURNISHED FOR OUTDOOR INSTALLATIONS. E.BUILDING WIRE, UNLESS OTHERWISE INDICATED, SHALL BE COPPER, 600 VOLT, TYPE THWN/THHN INSULATION, #12 AWG MINIMUM, FOR INTERIOR AND EXTERIOR USE. FOR BRANCH CIRCUITS TYPE MC (METAL CLAD) CABLE MAY BE USED WHERE PERMITTED BY THE NEC AND LOCAL CODES. NO ROMEX OR AC (BX) CABLE WILL BE ALLOWED ON THE PROJECT. F.MINIMUM WIRE SIZE SHALL BE NUMBER TWELVE (12) AWG. NO SPLICES SHALL BE MADE EXCEPT WITHIN OUTLET OR JUNCTION BOXES. WIRES NUMBER EIGHT (8) AWG AND LARGER SHALL BE STRANDED. WIRES AND CABLES SHALL BE MANUFACTURED BY PIRELLI, ROYAL, TRIANGLE OR EQUIVALENT. G.THE COLOR CODING SYSTEM LISTED BELOW SHALL BE USED THROUGHOUT THE BUILDING: SYSTEM PHASE A PHASE B PHASE C NEUTRAL GROUND ISOLATED GROUND 120/208V BLACK RED BLUE WHITE GREEN GREEN/YELLOW 277/480V BROWN ORANGE YELLOW GRAY GREEN GREEN/YELLOW H.THE WIRE SIZE INDICATED IN THE HOMERUN SHALL BE USED THROUGH THE CIRCUIT. I.PROVIDE DISCONNECT SWITCHES WHERE INDICATED AND AS REQUIRED. SWITCHES SHALL BE OF SIZE, NUMBER OF POLES AND FUSED OR NONFUSED, AS REQUIRED FOR JOB CONDITIONS AND THE NATIONAL ELECTRICAL CODE. ALL SAFETY SWITCHES SHALL BE NEMA I ENCLOSURE "HD" WITH INTERLOCKING COVER AND HANDLE, MANUFACTURED BY SQUARE "D" OR APPROVED EQUAL. PROVIDE NEMA 3R ENCLOSURES WHERE REQUIRED. J.PROVIDE STARTERS AND CONTROL WIRING AS INDICATED ON THE DRAWINGS, OR SPECIFIED HEREIN. ALL TEMPERATURE CONTROL WIRING AND COMPONENTS SHALL BE UNDER DIVISION 15. K.PROVIDE THERMAL MANUAL MOTOR STARTING SWITCHES FOR FRACTIONAL HORSEPOWER, SINGLE PHASE MOTORS. THE STARTERS SHALL BE SQUARE D COMPANY, CLASS 2510, ALLEN BRADLEY BULLETIN 600, OR APPROVED EQUAL FOR SING LE SPEED MOTORS. ENCLOSURES SHALL BE NEMA I FOR INTERIOR USE AND NEMA 3R FOR EXTERIOR USE. L.THREE PHASE MOTOR STARTERS SHALL BE 3 POLE, FULL-VOLTAGE, MAGNETIC TYPE. ENCLOSURES SHALL BE NEMA I FOR INTERIOR USE AND NEMA 3R FOR EXTERIOR USE. PROVIDE HOA SWITCH WHEN AUTOMATICALLY CONTROLLED, PILOT INDICATING LIGHT, CONTROL TRANSFORMER, AND NO/NC AUXILIARY CONTACTS. STARTERS SHALL BE SQUARE D COMPANY, CLASS 8536 AND CLASS 8538 COMBINATION TYPE OR APPROVED EQUAL. M.WIRING DEVICES SHALL BE ARROW HART, GENERAL ELECTRIC, P & S LEVITON OR HUBBELL: 1)WALL SWITCHES: ARROW HART 1991. THREE AND FOUR-WAY SWITCHES SHALL BE OF THE SAME MANUFACTURER AND GRADE. 2)RECEPTACLES: ARROW HART 5362 FOR 20 AMPERES. GFCI SHALL BE #GFCS20 RATED 20 AMPERE, 120 VOLT. PROVIDE TAMPER RESISTANT AND MOISTURE RESISTANT TYPE WHERE REQUIRED BY NEC. 3)DIMMERS: 600/1000/1500/2000 WATTS AS REQUIRED BY JOB CONDITIONS. LUTRON 'NOVA' SERIES OR EQUAL. 4)DEVICE PLATES: ARROW HART SWITCH PLATES SI-S6 SERIES. ARROW HART RECEPTACLE PLATES S8. ARROW HART TELEPHONE BLANK PLATES S14. N.MOUNT WEATHERPROOF DEVICES IN CAST METAL BOXES WITH GASKETED, SPRING-HINGED LID-TYPE LOCKING COVERS HAVING CORROSION-RESISTANT FINISH. O.THE ENTIRE ELECTRICAL SYSTEM SHALL BE SOLIDLY GROUNDED INCLUDING MAIN SERVICE EQUIPMENT, DISCONNECT SWITCHES, WIRING TROUGHS AND PULL BOXES, CONDUIT SYSTEM, OUTLET BOXES, MOTORS, ELECTRIC HEATING EQUIPMENT, LIGHTING FIXTURES, TRANSFORMERS, EMERGENCY SYSTEMS, UPS SYSTEMS, AND FIRE ALARM SYSTEMS. P.PROVIDE EQUIPMENT GROUNDING CONDUCTORS IN ALL BRANCH CIRCUITS AND FEEDERS SIZED IN ACCORDANCE WITH THE NEC TABLE 250.112. Q.ALL BRANCH CIRCUITS SHALL BE RUN CONCEALED IN EXISTING AND NEW WALLS. CUT AND PATCH EXISTING WALLS AND SURFACES AS REQUIRED. R.ALL D.C. WIRING SHALL BE #10 AWG MINIMUM. S.GROUND, PHASE AND NEUTRAL CONDUCTORS SHALL BE PIG -TAILED IN OUTLET BOXES OR MULTI-OUTLET ASSEMBLY FOR RECEPTACLES SO THAT GROUND AND ELECTRICAL SERVICE W ILL NOT BE DISRUPTED TO OTHER RECEPTACLES ON THE SAME MULTI-WIRE CIRCUIT IF RECEPTACLE IS REMOVED. 3.SECTION 16400 -SERVICE AND DISTRIBUTION A.COORDINATE ALL SERVICE ENTRANCE WORK WITH THE ELECTRIC UTILITY. B.DISTRIBUTE POWER AT 120/208V, 3 PHASE, 4 WIRE, LED LIGHTING, AIR CONDITIONING, ELECTRIC HEATING, MOTOR CIRCUITS, AND 120/208V FOR RECEPTACLES, INCANDESCENT LIGHTS AND SMALL MOTORS. C.PANELBOARDS SHALL BE 120/208 VOLTS, THREE PHASE EMPLOYING BREAKERS MINIMUM 10,000 SYMMETRICAL AIC AT 120 VOLTS. FURNISH PANELBOARDS AS INDICATED ON DRAWINGS E6.0, E7.0 AND E7.1. D.PANELBOARDS SHALL BE FACTORY ASSEMBLED WITH BOLT-ON TYPE CIRCUIT BREAKERS. BUSS SHALL BE ALUMINUM. PROVIDE 50% GROUND BUS BAR. PANELS CONNECTED TO K-RATED TRANSFORMERS SHALL HAVE 200% RATED NEUTRAL BUS BARS. E.PROVIDE THREE (3) 3/4 INCH SPARE CONDUITS FROM EACH RECESSED PANEL TO THE CEILING SPACE. F.FUSES FOR SERVICE ENTRANCE EQUIPMENT SHALL BE U.L. LISTED CLASS L, J, OR RKI. FUSES FOR FEEDER CIRCUITS AND PANELBOARDS SHALL BE U.L. CLASS RKI FAST-ACTING TYPE. FUSES FOR MOTOR OVERCURRENT, MOTOR CONTROLLER, AND TRANSFORMER PROTECTION SHALL BE DUAL-ELEMENT, U.L. CLASS RKI TIME-DELAY TYPE. G.PROVIDE ENERGY EFFICIENT, NEMA TP-1, SELF-COOLED, DRY TYPE TRANSFORMERS OF KVA, PHASE, "K" AND VOLTAGE RATINGS AS INDICATED. TRANSFORMERS 15 KVA AND LESS SHALL HAVE A CLASS F INSULATION, 115 DEGREES C RISE. TRANSFORMERS ABOVE 15 KVA SHALL HAVE CLASS H INSULATION, 115 DEGREE C RISE. PROVIDE FOUR 2-1/2 TAPS BELOW TWO 2-1/2 TAPS ABOVE RATED PRIMARY VOLTAGE. TRANSFORMERS OF 150 KVA AND LESS SHALL BE RATED 45 DB, LARGER TRANSFORMERS SHALL BE RATED 55 DB. NEUTRALS AND NEUTRAL CONNECTIONS OF ALL "K" RATED DRY TYPE TRANSFORMERS SHALL BE 200% OF THE PHASE CONDUCTOR SIZE. TRANSFORMER SHALL BE HEVI-DUTY ELECTRIC COMPANY, GENERAL ELECTRIC, SORGEL, ACME OR HOWARD INDUSTRIES. 4.SECTION 16500 -LIGHTING A.PROVIDE A COMPLETE LIGHTING FIXTURE AT EACH LOCATION INDICATED ON THE DRAWINGS. FIXTURES SHALL BE SPECIFIED ON THE LIGHTING FIXTURE SCHEDULE ON THE DRAWINGS. B.ALL PLASTIC DIFFUSERS SHALL BE 100 PERCENT VIRGIN ACRYLIC (NOMINAL .125 INCH THICK) AND ALL LEXAN DIFFUSERS SHALL BE LEXAN TYPE MR-4000, OR EQUAL. C.8-FOOT TANDEM UNITS MAY BE USED IN LIEU OF 4 FOOT UNITS IN CONTINUOUS ROWS. D.THE CONTRACTOR SHALL CONSULT THE CEILING CONTRACTOR AND ARCHITECT'S DRAWINGS FOR APPROVED REFLECTED CEILING PLANS BEFORE ORDERING FIXTURES TO INSURE THAT ALL ARE COMPATIBLE WITH THE CEILING SYSTEM AND PROPERLY LOCATED. VERIFY THAT ADEQUATE CLEARANCE FO R INSTALLATION, MAINTENANCE, AND HEAT DISSIPATION IS AVAILABLE. E.PROVIDE A MINIMUM OF TWO (2) GALVANIZED STEEL #12 GAUGE HANGER WIRES (ALTERNATE CORNERS) ON ALL RECESSED FIXTURES. F.CONTRACTOR SHALL PROVIDE ADDITIONAL EXIT LIGHTS AND EMERGENCY BATTERY PACK WITH DUAL HEADS AS NEEDED TO MEET FIRE MARSHAL'S WALK-THROUGH AND ACCEPTANCE. G.CONNECT EXIT LIGHTS, EMERGENCY BATTERY UNITS AND NIGHT LIGHTS (NL) TO UNSWITCHED PORTION OF LIGHTING CIRCUIT SERVING RESPECTIVE AREA. 5.SECTION 16700 -COMMUNICATION SYSTEMS A.TELEPHONE SERVICE SHALL BE INSTALLED BY THE TELEPHO NE COMPANY. B.PROVIDE WALL OUTLETS IN 4" SQUARE 2-1/8" DEEP BOX WITH RAISED SINGLE GANG COVERS EQUIPPED WITH BLANK STAINLESS STEEL DEVICE PLATES. EXTEND 3/4" EMPTY CONDUIT FROM EACH OUTLET TO THE CEILING SPACE AND TERMINATE WITH INSULATED BUSHINGS. PROVIDE NYLON PULL WIRE IN ALL CONDUITS LEFT EMPTY. REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E0.1 PROJECT NUMBER: 24212 ELECTRICAL SPECIFICATIONS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST W/C ONCAVE S E A T S SG 150D O R S G 150P WABA S H VAL LEY 46" R OUND T ABL E W/C ONCAVE S E A T S SG 150D O R S G 150P WABA S H VAL LEY 46" R OUND T ABL E SHUT- O FF SHUT- O FF EXTERI O R RO O FACCE SS LAD DER W 12 K D I E S E L ( 1 0 ' D I A . ) 8K CK CHOICE12K SUL 20K REGULAR JJJJJJ J J J J JJ J JJJJJ J J J J 1 0 ' - 0 " SLEEVE DRIVE SLEEVE DRIVE C - 29 6 G -2 G -6 G -10 G -14 G -18 G -26 REFERENCE DETAIL 5-E1.1 FOR ENLARGED DISPENSER DETAIL, TYP A3B A4B A4B A4B A4B 3/4"C,2#10,#10G 3/4"C,2#10,#10G A - 2,4 1"C,4#10,2#10G 7 A - 6,8 1"C,4#10,2#10G 7 C - 17 3/4"C,2#10,#10G 8 T 9 10 1112TYP 13 14 15 16 17 1814 1914 20 TYP 21 2122 G - 1,3 22 21 21 21 22 G - 17,19 21 21 22 23 23 2TYP 24 25 1 1 3/4"C,2#8,#8G2122 G - 13,15 21 G - 5,7 G - 9,11 21 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 11 26 A3B A4B A - 22 A3B A - 20 A4B A3B 1 ROUTE A-4 VIA LIGHTING CONTROL ROUTE A-8 VIA LIGHTING CONTROL 1 G -30 G -34 3/4"C,2#10, 1#10 GR 3/4"C,2#10, 1#10 GR 1 0' - 0" 2 0' - 0" 2 0 ' - 0 " 23 A4B A4B G -22REFERENCE DETAIL 3-E1.1 FOR LIGHT POLE BASE DETAIL, TYP CAN2 CAN2 CAN1CAN1 CAN1 CAN1 CAN2CAN2 CAN2 CAN2 CAN1CAN1 CAN1 CAN1 CAN2CAN2 CAN2 CAN2 CAN1CAN1 CAN2 CAN2 CAN1CAN1 CAN1 CAN1 CAN2CAN2 A-13,15 A-13,15A-13,15 A-13,15A-13,15 A-13,15A-13,15 A-13,15A-13,15 A-13,15 A-13,15 A-13,15A-13,15 A-13,15A-9,11 A-9,11A-9,11 A-9,11A-9,11 A-9,11A-9,11 A-9,11A-9,11 A-9,11 A-9,11 A-9,11A-9,11 A-9,11 A - 13,15A - 9,11 11 2 TYP 2#10,#10G,3/4"C 2#10,#10G,3/4"C 14 ' - 0 " TYP TYP TY P TY P TY P A - 5 A - 1,3 A - 1 A - 5 A - 5 A - 5 A - 5 A - 5A - 5 3 3 4 TYP 5 5 2#10,#10G,3/4"C 5' - 0 " 5' - 0 " 2#12,#12G,3/4"C 7' - 0"7' - 0" A -1 27TYP 1 1 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E1.0 PROJECT NUMBER: 24212 ELECTRICAL SITE PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 1" = 20'-0" 1 ELECTRICAL SITE PLAN 1" = 10'-0" 2 CANOPY LIGHTING PLAN KEYNOTES 1 SITE LIGHTING CIRCUITS SHALL BE ROUTED VIA 20A ELECTRICALLY HELD LIGHTING CONTACTORS CONTROLLED BY THE 'EPO' SWITCHES AND PHOTOCELL. 'EPO' SWITCHES LOCATED AT THE FUEL CANOPY AND STORE ON THE SITE. REFERENCE DETAIL 2/E6.0. 2 PROVIDE SEAL-OFF FITTINGS AT EACH END OF CONDUIT IN CONJUNCTION WITH / G.V.R. DISPENSER MANUAL. REFERENCE DETAIL 4/E1.1. 3 PROVIDE AND INSTALL WP JUNCTION BOXES IN CANOPY FOR WHITE SPEAKERS. MAKE CONNECTIONS TO CONDUITS PROVIDED IN CANOPY COLUMN. 4 CANOPY EYEBROW LED STRIP LIGHTS. ONE DOUBLE KWIK BOX POWER CONNECTION PER EACH GROUP OF FOUR SECTIONS. 5 WP JUNCTION BOX FOR COMPLETE CONNECTION OF CANOPY SIGN. VERIFY EXACT LOCATION IN FIELD. 6 PROVIDE WEATHERPROOF DISCONNECT SWITCH FOR WATER / AIR FILL STATION. VERIFY EXACT LOCATION IN FIELD, AND VERIFY REQUIREMENTS PRIOR TO ROUGH-IN 7 PROVIDE WEATHERPROOF DISCONNECT SWITCH. COORDINATE EXACT CONNECTION AND WIRING REQUIREMENTS WITH SIGN CONTRACTOR AND FINAL SECTION PRIOR TO INSTALLATION. PROVIDE (2) 1" CONDUITS, ONE FOR POWER AND ONE FOR PHONE AND COMMUNICATION. 8 HEAT TRACE TO BE PROVIDED FOR BACKFLOW PREVENTER IN COLD REGION. 9 PROVIDE HOUSEKEEPING PAD FOR POWER CO. PAD MOUNTED TRANSFORMER PER UTILITY COMPANY REQUIREMENTS. 10 REFER TO ONE-LINE DIAGRAM FOR CONDUCTOR AND CONDUIT SIZES. VERIFY WITH POWER COMPANY. 11 FUEL DISPENSER CONDUITS FOR POWER, INTERCOM, CRIND DATA AND SENSORS. REFERENCE DETAIL 5/E1.1 AND FUEL SYSTEM VENDOR DRAWINGS. 12 (1) 3/4" CONDUIT AND (3) 1" CONDUITS FROM ELECTRICAL ROOM / MECHANICAL ROOM, TO CLOSEST CANOPY COLUMN. ROUTE CONDUITS UP TO CANOPY DECK FOR SPEAKER/SECURITY CAMERA CONNECTIONS. PROVIDE PULL STRINGS IN ALL CONDUITS. 13 CLASS 1 DIVISION 2 HAZARDOUS AREA: OUTDOOR DISPENSING DEVICE: UP TO 18" OF DISPENSER ENCLOSURE, EXTENDING 20 FT. HORIZONTALLY IN ALL DIRECTIONS FROM DISPENSER ENCLOSURE. PER NEC TABLE 514.3(8)(1). 14 ALL WIRING IN THIS AREA INCLUDING BELOW GRADE SHALL BE INSTALLED IN RIGID CONDUIT PER NEC ARTICLE 514.8. HOWEVER, PER NEC 514.8 EXCEPTION 2, NONMETALLIC RIGID CONDUIT (PVC) HAVING A MINIMUM OF 24" OF GROUND COVER IS ALLOWED. IN ADDITION, THREADED RIGID METAL CONDUIT OR THREADED STEEL INTERMEDIATE METAL CONDUIT SHALL BE USED FOR THE LAST 2 FEET OF THE UNDERGROUND RUN TO EMERGENCE OR TO THE POINT OF CONNECTION TO THE ABOVE GROUND RACEWAY, AND AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INCLUDED. PROVIDE ALL EXPLOSION PROOF FITTINGS AND SEALS NECESSARY TO COMPLETE CONDUIT SYSTEMS. NO SUBSTITUTIONS SHALL BE MADE UNLESS APPROVED BY THE AUTHORITY HAVING JURISDICTION. PROVIDE EXPLOSION PROOF JUNCTION BOXES (CROUSE HINDS) MODEL GUP215 WITH 0302 'O' RING OR OWNER APPROVED EQUAL. 15 CLASS 1 DIVISION 1 HAZARDOUS AREA: UNDERGROUND TANK VENT: WITHIN 5 FT. OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. PER NEC TABLE 514.3(B)(1). 16 CLASS 1 DIVISION 2 HAZARDOUS AREA: UNDERGROUND TANK VENT: BETWEEN 5 FT. AND 10 FT. OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. PER NEC TABLE 514.3(B)(1). 17 VENT RISERS FROM TANKS. 18 CLASS 1 DIVISION 2 HAZARDOUS AREA: UNDERGROUND TANK FILL OPENING: UP TO 18" ABOVE GRADE LEVEL, EXTENDING 5 FT. HORIZONTALLY IN ALL DIRECTIONS FROM ANY LOOSE-FILL CONNECTION. PER NEC TABLE 514.3(B)(1). 19 CLASS 1 DIVISION 1 HAZARDOUS AREA: UNDERGROUND TANK: INSIDE TANK - ENTIRE INSIDE VOLUME. FILL OPENING - ENTIRE SPACE WITHIN ANY PIT OR BOX BELOW GRADE LEVEL. PER NEC TABLE 514.3(B)(1). 20 TANK FILL STATION. 21 3/4" CONDUIT FOR POWER/STP CONTROL. REFERENCE DETAIL 1/E1.0 FOR POWER CIRCUIT DESIGNATION, CONDUIT AND WIRE SIZE. PROVIDE 4#12 THWN2 FOR STP AUTHORIZATION. VERIFY STP AUTHORIZATION CONDUCTOR QUANTITY, SIZE AND TYPE PER DISPENSER WITH FUEL VENDOR DRAWINGS. 22 3/4" CONDUIT FOR TANK MOTION SENSORS. INSTALL CONDUIT TO SUMP AND INTERSTITIAL SENSORS AT TANKS. REFERENCE FUEL SYSTEM VENDOR DRAWINGS FOR CONDUCTORS TO BE INSTALLED TO SENSORS. 23 "EMERGENCY POWER OFF" SWITCH PER NEC ARTICLE 514.11. PROVIDE SIGNAGE PER IFC SECTION 2204, 2205 (VERIFY EXACT LOCATION WITH CIRCLE 'K' CONSTRUCTION MANAGER). 24 SERVICE ENTRANCE DISCONNECT PER UTILITY REQUIREMENTS. 25 (2) 4" EMPTY CONDUITS FOR TELEPHONE SERVICE. VERIFY EXACT QUANTITY AND SIZE WITH SERVING TELEPHONE COMPANY. 26 STORE ELECTRICIAN SHALL ROUGH IN CONDUIT AT ELECTRICAL ROOM AND RUN TO PETROLEUM ELECTRICIAN'S POINT OF INTERCEPTION 30 FEET FROM FRONT OF STORE. PETROLEUM ELECTRICIAN SHALL INTERCEPT CONDUIT AND COMPLETE RUNS TO DISPENSERS, CANOPY AND FUEL TANKS. PETROLEUM ELECTRICIAN SHALL FURNISH AND INSTALL ALL WIRING. REFERENCE FUEL SYSTEM VENDOR DRAWINGS FOR ALL REQUIRED CONDUIT, WIRE AND CIRCUITRY. 27 CANOPY GROUNDING: REFERENCE DETAILS 1 & 2/E1.1. GENERAL NOTES 1. ALL EXTERIOR DEVICES SHALL BE WEATHERPROOF. 2. ALL FUEL ISLAND CONDUIT SHALL BE ROUTED TO THE RESPECTIVE PANELS AND / OR TO THE FUEL CONTROL PANELS LOCATED IN THE MANAGER'S OFFICE / STORAGE ROOM. 3. PROVIDE EMPTY CONDUITS WITH PULL STRING. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL UTILITY COMPANY FOR THE EXACT LOCATION OF ALL PRIMARY SERVICE EQUIPMENT, TRENCH LOCATIONS, TRANSFORMER LOCATION, METER LOCATION, ETC. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY SECONDARY CONDUITS, POWER TRENCHING, BACKFILL, CONCRETE PADS FOR TRANSFORMERS AND SERVICE EQUIPMENT AND CONDUIT STUBS INTO TRENCH AS REQUIRED BY ELECTRICAL UTILITY COMPANY SPECIFICATIONS. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH TELEPHONE UTILITY COMPANY FOR THE EXACT LOCATION OF ALL PRIMARY SERVICE EQUIPMENT, SERVICE EQUIPMENT, TRENCH LOCATIONS, ETC. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY TELEPHONE TRENCHING, BACKFILL AND CONDUIT STUBS INTO TRENCH AS REQUIRED BY TELEPHONE UTILITY COMPANY SPECIFICATIONS. 7. ALL WIRING OUTSIDE SHALL BE A MINIMUM OF #10 COPPER WITH TYPE 'XHHW-2' INSULATION FOR UNDERGROUND CIRCUIT RUN IN PVC, PROVIDE A #10 COPPER BOND IN ADDITION TO CIRCUIT CONDUCTORS. 8. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION AND COMPLIANCE WITH THE UTILITY COMPANY'S REQUIREMENTS. WITHIN TWO WEEKS AFTER AWARD OF CONTRACT, SUBMIT (2) COMPLETE SETS OFF PLANS, INCLUDING PLOT OF SURVEY, TO UTILITY COMPANY FOR COORDINATION. ROUTING OF INCOMING POWER AND TELEPHONE SERVICE SHOWN ARE FOR ESTIMATING PURPOSES ONLY. ACTUAL ROUTING, CONDUIT, TRENCH AND PAD REQUIREMENTS SHALL BE AS SPECIFIED BY THE UTILITY COMPANY. CONFIRM ALL REQUIREMENTS WITH UTILITIES PRIOR TO INSTALLATION.. 9. ALL UNDERGROUND CABLE, PIPE AND CONDUITS SHALL BE DETECTABLE (METALLIC) OR HAVE A DETECTABLE UNDERGROUND DEVICE INSTALLED PER LOCAL CODES. OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST J METAL FRAME COMPRESSION LUG OR EXOTHERMIC WELD GROUNDING CONNECTION. TYPICAL. BONDING JUMPER, TYPICAL SE E E L E C T . & P H O T O M E T R I C #3/0 AWG LUMINAIRE, REFERENCE SITE LIGHTING VENDOR PLAN SQUARE STEEL POLE WITH FINISH TO MATCH FIXTURE AND BE APPLIED BY MFR. CEM-TEK OR EQUAL. WIND LOAD RATING -97 MPH AB'S AS REQUIRED BY MFR. (MIN 24' EMBED) GROUND LUG FOR BOND CONDUCTORS (INSIDE POLE ACCESSIBLE FROM HANDHOLE) HANDHOLE 3' -0" 23 ' M A X . C O M M E R C I A L A R E A 15 ' M A X . N E X T T O R E S I D E N T I A L A R E A FINISHED GRADE NOTE: SEE STRUCTURAL FOR LIGHT POLE BASE REINFORCING LIQUID SEALANT FILLER OPENING WITH CAP POWER AND COMMUNICATION WIRING TO FIT500 ENCLOSURE SEALING FITTING CONDUIT SEALANT GROUND LEVEL TO SITE POWER AND SITE CONTROLLER CONDUIT ENTERING THE HAZARDOUS AREA MUST HAVE A SEAL-OFF INSTALLED +18" ABOVE GRADE TO PREVENT LIQUID OR FUMES FROM ENTERING THE AREA REF DETAIL 1-E1.0 FOR CIRCUIT DESIGNATION 1 23 4 5 TYP FUEL DISPENSER. COORDINATE CONDUIT ENTRANCE LOCATIONS WITH MANUFACTURER INSTRUCTIONS20' - 0 " C L A S S I F I E D A R E A R A D I U S LOW VOLTAGE SECTION FUEL CONTROLS, PANELS A, B &G PANELS MDP, C, D, E LIGHTING CNTRL, PANEL U DISPENSER LOW VOLTAGE CONTROLS AND MONITORING CONDUITS FUEL TANK SENSOR CONDUITS DISPENSER POWER CONDUITS FUEL TANK POWER CONDUITS FUEL CANOPY LIGHTING AND SIGNAGE POWER CONDUITS 13' - 9" 1' - 0 " INTEGRATED SWITCHGEAR DETAIL IS DIAGRAMMATIC IN NATURE. REFERENCE FUEL VENDOR DRAWINGS FOR EXACT QUANTITY AND SIZE OF REQUIRED DISPENSER, TANK AND CANOPY CONDUITS. REFERENCE SWITCHGEAR VENDOR DRAWINGS FOR EXACT LOCATION OF CONDUIT ENTRY LOCATIONS IN SWITCHGEAR SECTIONS. FUEL CANOPY SPEAKER AND SECURITY CAMERA CONDUITS GAS CANOPY STEEL COLUMN (TYPICAL) #3/0 CU, EQUIPOTENTIAL GROUND (TYPICAL) GROUND ROD GROUND ROD REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E1.1 PROJECT NUMBER: 24212 ELECTRICAL SITE PLAN DETAILS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA KEYNOTES 1 PROVIDE SEAL-OFF FITTINGS AT EACH END OF CONDUIT IN CONJUNCTION WITH / G.V.R. DISPENSER MANUAL. REFERENCE DETAIL 4/E1.1. 2 3/4" CONDUIT FOR POWER/STP CONTROL. REFERENCE DETAIL 1/E1.0 FOR POWER CIRCUIT DESIGNATION, CONDUIT AND WIRE SIZE. PROVIDE 4#12 THWN2 FOR STP AUTHORIZATION. VERIFY STP AUTHORIZATION CONDUCTOR QUANTITY, SIZE AND TYPE PER DISPENSER WITH FUEL VENDOR DRAWINGS. 3 3/4" CONDUIT FOR DISPENSER MONITORING SENSOR IN DISPENSER SUMP. REFERENCE FUEL SYSTEM VENDOR DRAWINGS FOR QUANTITY AND TYPE OF CONDUCTORS TO BE INSTALLED. 4 3/4" CONDUIT TO SWITCHGEAR LOW VOLTAGE SECTION FOR DISPENSER INTERCOM. REFERENCE FUEL SYSTEM VENDOR DRAWINGS FOR QUANTITY AND TYPE OF CONDUCTORS TO BE INSTALLED PER DISPENSER. 5 3/4" CONDUIT FOR CRIND DATA. REFERENCE FUEL SYSTEM VENDOR DRAWINGS FOR QUANTITY AND TYPE OF CONDUCTORS TO BE INSTALLED PER DISPENSER. N.T.S. 2 CANOPY GROUNDING N.T.S. 3 LIGHT POLE BASE N.T.S. 4 SEAL OFF DETAIL 3/16" = 1'-0" 5 FUEL DISPENSER ENLARGED 1/2" = 1'-0" 6 SITE FUEL EQUIPMENT CONDUIT ROUGH-IN N.T.S. 1 CANOPY GROUNDING DETAIL OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST 1.8 3.2 5.3 6.8 8.0 7.7 6.6 5.1 3.3 2.5 2.8 4.1 5.8 7.2 8.2 7.4 6.0 4.3 2.5 2.0 2.5 1.5 2.6 4.2 5.6 6.1 6.7 6.6 6.1 5.8 4.5 3.8 4.0 5.3 6.0 6.4 6.8 6.5 5.8 5.1 3.4 2.8 3.9 4.6 1.6 2.4 3.4 4.7 5.5 5.6 5.7 5.8 5.9 6.0 5.6 5.1 5.3 5.9 5.9 5.9 5.8 5.7 5.6 5.2 4.1 3.4 4.3 5.6 5.7 3.9 3.1 4.5 6.7 8.4 9.4 9.7 9.8 10.0 9.9 10.0 10.1 9.9 10.0 10.0 9.9 9.9 9.9 9.7 9.5 8.8 7.5 5.9 5.3 6.5 7.8 8.5 8.9 6.7 6.1 10.7 23.0 29.1 30.3 31.0 31.2 31.1 31.4 31.6 31.2 31.9 31.5 31.7 31.8 31.6 31.7 31.5 30.6 29.6 26.3 17.1 8.2 7.4 8.2 6.2 9.1 7.5 7.8 7.8 12.3 7.6 7.1 1.9 4.6 6.8 6.1 4.9 7.4 13.6 7.4 6.1 4.7 2.6 2.0 2.8 3.9 3.0 2.9 6.1 11.0 6.0 4.4 1.8 9.3 7.6 4.6 2.5 1.8 1.7 1.7 2.3 4.1 9.1 16.1 20.1 21.8 22.1 22.2 22.6 22.3 22.4 22.7 22.4 22.4 22.3 22.3 22.3 22.2 22.1 22.0 20.3 18.1 13.1 6.3 4.0 3.1 1.9 7.8 8.7 6.9 5.6 2.4 1.6 1.4 1.4 1.9 2.9 5.0 7.3 9.0 9.9 10.3 10.4 10.4 10.5 10.5 10.5 10.5 10.5 10.5 10.4 10.5 10.5 10.2 10.1 9.5 8.1 6.0 3.9 3.1 4.0 4.7 4.2 2.1 1.1 1.2 3.0 5.9 7.2 6.2 4.1 2.1 1.4 1.1 1.6 2.3 2.9 3.3 4.1 4.9 5.3 5.7 5.8 5.7 5.8 5.8 5.7 5.7 5.7 5.7 5.8 5.9 5.9 5.8 5.6 5.2 4.4 3.5 2.8 2.9 5.2 6.9 6.7 5.3 5.5 2.5 1.6 2.2 4.3 6.3 7.3 5.1 2.6 1.1 1.1 4.2 5.3 5.0 3.0 2.7 3.0 3.3 3.6 3.8 3.8 3.6 3.4 3.3 3.3 3.3 3.4 3.6 4.0 4.3 4.5 4.3 3.8 3.4 2.9 2.6 3.1 6.1 9.2 9.9 5.0 8.2 6.5 5.1 2.4 2.4 5.2 6.8 7.9 7.6 3.6 7.1 8.1 6.7 3.2 2.2 2.4 2.8 3.5 4.4 4.4 3.3 2.6 2.2 2.1 2.2 2.5 3.1 4.4 5.7 6.0 5.9 5.4 5.4 5.0 4.2 4.0 3.3 8.8 8.3 6.6 3.5 2.7 5.3 7.7 10.0 6.4 8.5 9.0 6.5 3.2 2.1 2.6 3.6 5.3 8.8 8.9 4.4 2.3 1.8 1.6 1.7 2.1 3.4 7.4 11.2 9.2 8.0 7.5 7.4 6.9 5.9 4.9 3.2 6.4 4.2 2.5 2.0 3.3 6.0 6.3 7.7 6.8 3.2 2.4 3.5 6.4 7.4 9.0 15.0 12.2 10.3 9.8 9.5 10.3 10.4 10.2 14.4 13.5 8.5 9.3 8.4 8.2 7.4 5.0 3.4 1.8 1.6 1.2 1.1 1.1 3.5 5.3 5.6 9.4 5.2 2.7 6.3 7.0 3.7 1.8 1.6 2.2 5.3 5.4 3.4 7.8 6.5 5.0 8.5 5.8 34 38 41 45 45 46 46 44 45 47 47 46 46 44 46 46 47 46 45 45 47 47 46 46 44 46 47 47 46 45 44 46 46 45 45 41 38 34 40 33 36 45 53 53 45 36 41 55 53 54 43 0 45 54 53 49 39 39 49 53 54 45 0 43 54 53 54 41 36 45 53 53 45 36 32 40 39 38 41 53 53 53 53 43 46 54 53 54 54 27 54 54 54 54 45 45 54 54 54 54 27 54 54 53 54 46 42 53 53 52 53 41 37 39 36 30 40 42 48 49 49 51 47 50 51 50 48 51 49 50 51 50 52 52 50 51 50 49 51 48 50 51 50 47 51 49 49 48 42 39 31 35 34 38 41 47 44 45 48 47 48 46 45 46 48 47 48 46 45 48 47 47 48 45 46 48 47 48 46 45 46 47 47 48 44 44 46 40 37 33 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.8 1.2 1.2 0.8 0.6 0.5 0.5 0.5 0.5 0.6 1.0 1.3 1.0 0.6 0.5 0.5 0.5 0.6 0.6 0.3 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 1.1 2.0 3.6 3.2 1.7 1.2 0.9 0.9 0.9 1.0 1.3 2.4 3.8 2.7 1.4 0.9 0.8 0.9 1.2 1.3 0.6 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.6 1.0 2.7 1.4 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.6 0.9 3.4 0.6 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.4 0.6 0.9 1.1 1.3 0.5 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 1.1 2.1 4.3 2.9 0.9 0.3 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.7 2.3 3.3 1.1 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.9 2.2 0.8 0.3 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.2 0.1 0.1 0.2 0.1 0.3 0.5 0.6 0.7 1.9 2.1 0.8 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.3 0.5 1.4 2.0 0.9 0.7 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.5 0.5 0.4 0.5 1.1 3.2 1.2 1.1 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.3 0.6 0.8 0.7 0.7 0.8 2.6 4.1 2.2 0.9 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.4 1.2 2.5 6.3 3.3 1.1 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.6 3.1 7.2 3.2 0.8 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.5 0.9 1.7 3.4 3.5 1.8 0.7 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.5 2.2 1.4 0.8 2.1 2.1 1.4 0.8 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.2 1.2 2.3 3.0 0.4 0.9 0.7 1.5 1.1 0.7 0.5 0.4 0.2 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.3 0.7 1.2 0.9 0.9 0.6 0.5 0.6 1.1 4.0 3.6 4.7 10.3 11.9 6.7 3.8 2.8 1.6 1.1 0.8 0.7 0.7 0.6 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.5 0.5 0.4 0.4 0.3 0.3 0.4 0.5 0.3 6.9 6.7 5.2 7.5 6.3 7.7 5.0 2.2 1.4 1.2 1.5 1.9 1.0 0.6 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.2 9.3 7.4 4.6 4.5 3.2 4.0 3.4 1.9 1.3 1.8 4.2 5.6 2.6 0.9 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 1.3 4.5 7.5 7.5 5.5 4.0 6.3 5.2 7.0 4.4 1.8 1.2 1.9 5.0 7.4 3.0 0.9 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.7 1.5 1.7 1.7 3.5 9.5 8.8 11.2 5.5 1.7 0.8 1.4 4.7 7.5 2.4 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.5 1.0 2.4 5.7 5.0 1.8 6.0 9.2 4.9 4.8 9.3 6.7 4.0 7.6 8.3 3.0 3.2 5.7 3.5 1.2 0.6 0.4 0.7 1.5 1.9 1.0 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.6 1.2 1.9 1.9 2.6 6.3 9.0 5.7 5.7 9.2 7.2 4.9 7.8 8.2 3.6 1.8 1.8 1.4 0.7 0.4 0.2 0.2 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.7 0.8 1.4 2.4 3.0 2.6 2.7 3.2 2.9 2.5 2.9 2.8 1.6 1.0 0.7 0.6 0.4 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.6 0.8 0.9 1.0 1.0 1.1 1.0 1.0 1.0 0.9 0.7 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 41 L 42 L 43 L 44 L 45 L 46 L 47 L 48 L 49 L 50 L 51 L 77 WP 78 WP 79 WP 80 WP 81 WP 82 WP 83 WP 84 WP 85 WP 1 A3B 2 A3B 3 A3B 4 A3B 5 A4B 6 A4B 7 A4B 8 A4B 9 A4B 10 A4B 11 A4B 12 A4B 13 CAN1 14 CAN1 15 CAN1 16 CAN1 17 CAN1 18 CAN1 19 CAN1 20 CAN1 21 CAN1 22 CAN1 23 CAN1 24 CAN1 25 CAN1 26 CAN1 27 CAN2 28 CAN2 29 CAN2 30 CAN2 31 CAN2 32 CAN2 33 CAN2 34 CAN2 35 CAN2 36 CAN2 37 CAN2 38 CAN2 39 CAN2 40 CAN2 52 SF04 53 SF04 54 SF04 55 SF04 56 SF04 57 SF04 58 SF04 59 SF04 60 SF12 61 SF12 62 SF12 63 SF12 64 SF12 65 SF12 66 SF12 67 SF12 68 SF12 69 SF12 70 SF12 71 SF12 72 SF12 73 SF12 74 SF12 75 SF12 76 SF12 LUMINAIRE SCHEDULE SYMBOL QTY LABEL ARRANGEMENT LUMENS LLF BUG RATING WATTS/LUMINAIRE TOTAL WATTS MANUFACTURER CATALOG LOGIC 4 A3B Single 12072 1.030 B1-U0-G2 114.07 456.28 Lithonia Lighting RSX2 LED P2 50K R3 MVOLT SPA HS FAO 8 A4B Single 11790 1.030 B1-U0-G3 114.07 912.56 Lithonia Lighting RSX2 LED P2 50K R4S MVOLT SPA HS FAO 14 CAN1 Single 14198 1.030 B3-U0-G1 91.38 1279.32 Lithonia Lighting XPCNY LED ALO2-13L SWW2-50K FPCL MVOLT DWHXD M3 14 CAN2 Single 14940 1.030 B3-U0-G2 88.88 1244.32 Lithonia Lighting XPCNY LED ALO2-13L SWW2-50K FTL MVOLT DWHXD M3 11 L SINGLE 2238 1.030 N.A. 25.15 276.65 Lithonia Lighting LBR6 ALO2 20LM SWW1 (4000K) AR LSS MWD 90CRI WL 8 SF04 SF 4FT 110 1.000 N.A. 1.04 116.48 P-LED PL-OP2-PD324-P-NW 17 SF12 SF 12FT_1 110 1.000 N.A. 1.04 777.92 P-LED PL-OP2-PD324-P-NW 9 WP SINGLE 6659 1.030 B1-U0-G1 51.2609 461.348 Lithonia Lighting ARC2 LED P5 50K MVOLT FOOTCANDLE LEVELS CALCULATED AT GRADE USING INITIAL LUMEN VALUES LABEL AVG MAX MIN AVG/MIN MAX/MIN PAVED AREA 7.40 31.9 1.1 6.73 29.00 UNDER CANOPY 45.68 55 0 N.A. N.A. UNDEVINED 0.81 11.9 0.0 N.A. N.A. LUMINAIRE LOCATION SUMMARY LUM NO.LABEL MTG. HT. 1 A3B 18 2 A3B 18 3 A3B 18 4 A3B 18 5 A4B 18 6 A4B 18 7 A4B 18 8 A4B 18 9 A4B 18 10 A4B 18 11 A4B 18 12 A4B 18 13 CAN1 15.5 14 CAN1 15.5 15 CAN1 15.5 16 CAN1 15.5 17 CAN1 15.5 18 CAN1 15.5 19 CAN1 15.5 20 CAN1 15.5 21 CAN1 15.5 22 CAN1 15.5 23 CAN1 15.5 24 CAN1 15.5 25 CAN1 15.5 26 CAN1 15.5 27 CAN2 15.5 28 CAN2 15.5 29 CAN2 15.5 30 CAN2 15.5 31 CAN2 15.5 32 CAN2 15.5 33 CAN2 15.5 34 CAN2 15.5 35 CAN2 15.5 36 CAN2 15.5 37 CAN2 15.5 38 CAN2 15.5 39 CAN2 15.5 40 CAN2 15.5 41 L 12 42 L 12 43 L 12 LUMINAIRE LOCATION SUMMARY LUM NO. LABEL MTG. HT. 44 L 12 45 L 12 46 L 12 47 L 12 48 L 12 49 L 12 50 L 12 51 L 12 52 SF04 18.5 53 SF04 18.5 54 SF04 18.5 55 SF04 18.5 56 SF04 18.5 57 SF04 18.5 58 SF04 18.5 59 SF04 18.5 60 SF12 18.5 61 SF12 18.5 62 SF12 18.5 63 SF12 18.5 64 SF12 18.5 65 SF12 18.5 66 SF12 18.5 67 SF12 18.5 68 SF12 18.5 69 SF12 18.5 70 SF12 18.5 71 SF12 18.5 72 SF12 18.5 73 SF12 18.5 74 SF12 18.5 75 SF12 18.5 76 SF12 18.5 77 WP 14.5 78 WP 14.5 79 WP 14.5 80 WP 14.5 81 WP 14.5 82 WP 14.5 83 WP 14.5 84 WP 14.5 85 WP 14.5 NOTE: - ALL AREA LIGHTS ON NEW 15 FT. POLE MOUNTED ON 3 FT. CONCRETE BASE NA TURA L GRO UND NA TURA L GRO UND NA TURA L GRO UND A S P H A LT S U R F A C E ~ ~ W/CO NCAVE SE ATS SG150D OR SG 150P WABASH VA LLEY 46" RO UND TA BLE W/CO NCAVE SE ATS SG150D OR SG 150P WABASH VA LLEY 46" RO UND TA BLE SHUT- OFF SHUT- OFF EXTERIO R ROO FACCESS LADDER TRANSFORMER PAD (APPROX) APPROX LOCATION OF GREASE TRAP; 3 INCH INTERNAL DROP EXCAVATION HOLE K I L L I O N R O A D S E (MAJOR COLLECTOR) Y E L M A V E N U E / S R 5 1 0 ( M IN O R A R T E RIA L) (ACCESS ROAD) TRANSFORMER PAD (APPROX) W 12 K D I E S E L ( 1 0 ' D I A . ) 8K CK CHOICE12K SUL 20K REGULAR E XCE PTION 20' B.S.L.20' B.S.L. 2 0' B .S.L. 15' B.S.L. 15' B.S.L. 15' B.S.L. 15' B.S.L. 15' B.S.L. 8.5' 6.0' 3.9' E E W * * * S 39 °01'29"W 1 99.78' S88°15'36"E 433.15' 413.15'147.35' (151') N 4 7 °0 4'2 9 "E 9 1.2 4'(9 5.0 0') S 5 0 °23'1 2"E 6 07.8 6' S 5 0 °23'1 2"E 1 04.4 7'(1 07') S 5 0 °23'1 2"E 6 07.8 6' N01°30'23"E 437.31' E E E E E E E G G G G G G G G 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 8"S D 1 2"S D 12"SD L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S L/S MAG NAIL WITH WASHER MARKED "E-TRUE LS 2422 1" [N4 7°0 4'2 9"E 2 .33 '] 1/2" REBAR WITH CAP IL LEGIBLE E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T E/T T T T T T T T T T (#3926418) EASEMENT REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E1.2 PROJECT NUMBER: 24212 ELECTRICAL SITE PHOTOMETRIC PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA N.T.S. 1 ELECTRICAL SITE PHOTOMETRIC PLAN FOR INFORMATION ONLY OTP 11/12/24 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E1.3 PROJECT NUMBER: 24212 EXTERIOR LIGHT FIXTURE CUT SHEETS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA TYPE "A3B" & "A4B" LIGHT FIXTURE TYPE "CAN1" & "CAN2" LIGHT FIXTURE TYPE "L" LIGHT FIXTURE TYPE "WP" LIGHT FIXTURE FOR INFORMATION ONLY OTP 11/12/24 KB J J JJ J J J J J J JJ J J J J JJ SM SM SM SM SM J JJ JJ J J SM J J J C - 1 , 3 C - 2 , 4 C - 6 , 8 B - 2 2 C - 3 2 B - 15 B - 1 B - 3 B - 5 B - 4 B - 6 B - 2 C - 1 0 A - 2 5 9'-10" 9'-10" E - 3 9 C - 2 5 D - 3 0 FF -3 B - 23 B - 2 0 , 2 1 +90" +48" +90" +48" +90" +48" C - 34 9'-10" U - 2 U - 4 6'-6" U - 7 U - 5 B - 10 B - 9 B - 12,14 B - 11,13 B - 3 3 B - 3 1 B - 4 0 B - 3 2 B - 4 2 B - 3 6 C - 2 3 C - 2 4 , 2 6 D - 3 8 , 4 0 B - 17 C - 3 3 C - 3 5 A - 38,40,42 D - 2 5 C - 30 +4 4 " A - 24 SURFACE MOUNT AT CEILING, TYP EXTERIOR ROOF ACCESS LADDER B - 7 D - 26 FF-1 +18"+18" +30"+36" +30" +30" +30" +30" D - 7 D - 1 9 D - 12,15 D - 15 D - 1 0 D - 4 2 WP E - 31,33 D - 23 C - 36 B - 1 8 D - 5 B - 16 D - 1 7 , 1 9 9' -10 " A - 23 A - 32 A - 37 C - 31 WP (PART 1/2) B - 7 (PART 2/2) 9'-10"C - 9 (PART 1/2) (PART 2/2) C - 9 D - 14D - 16 +48" +48" C - 27 D - 3 D - 6 B - 37,39,41 B - 25,27,29 C - 37,39,41 D - 27,29 D - 9 U - 3 C - 40 U - 6 1TYP 22 TYP 3 TYP 4 5 6 7 8TYP 99 10 TYP 11 12TYP OF 2 A - 19 D - 8 1313 13 14 TYP INTERIOR E-STOP/CASHIER CONTROL PANEL MOUNTED UNDER COUNTER, FIELD VERIFY LOCATION WITH CONSTRUCTION MANAGER A - 28 WP WP WP WP WP WP WP D - 21 DOOR POINT OF ELECTRICAL CONNECTION, TYP +4 4 " +4 4 " +30"+36" FF - 2 15 16 9' -10 " 15 17 1818 4 E - 4 1 D - 1 1 + 88" C - 21 + 88" + 88" 19 WP EVAPORATOR COIL, TYP D - 1 +24" +24" +24"+24" +42"+42" 2020 D - 35 D - 37 B - 35 C - 38 U - 8 U - 1 SPLIT QUAD, CIRCUIT EACH HALF TO ONE CIRCUIT WP WP C - 42 WALK-IN COOLER 104 BACK ROOM 109 STORAGE ROOM 103 COLD VAULT 105WALK-IN FREEZER 106 SALES FLOOR 107 MEN'S RESTROOM 102 PREP AREA 110 CASHIER 108 STORE SERVICE ENTRANCE DISCONNECT UTILITY CT CABINET / METER PER UTILITY REQUIREMENTS DI S T R I B U T I O N P A N E L D P 1"C,3#4,#8G 99 3/4"C,2#10, #10G 3/4"C,3#10,#10G 21 22 WOMEN'S RESTROOM 101 D - 2 8 23 24 25 21 E - 42 E - 40 C - 19 26 + 10" C - 20,22 3/4"C,3#10,#10G FUEL DISPENSER CONDUITS INTERCOM G-39 DISTRIBUTION DATA G-41 DISTRIBUTION PANEL DP IS AN INTEGRATED ASSEMBLY INCLUDING PANELS A, B, C, D, E, G & U. REFERENCE VENDOR SHEETS 27 25 24 28 29 SITE LIGHTING AND FUEL CANOPY LIGHTING CONDUITS G - 37 30+36" +4 4 " B - 24 B - 8 C - 1 1 C - 1 2 D - 2,4 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E2.0 PROJECT NUMBER: 24212 ELECTRICAL FLOOR PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 1. ALL ELECTRICAL DEVICES SHALL BE WEATHERPROOF. 2. ALL 125V THROUGH 250V RECEPTACLES SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150V OR LESS TO GROUND, 50A OR LESS, AND ALL RECEPTACLES SUPPLIED BY THREE-PHASE CIRCUITS RATED 150V OR LESS TO GROUND, 100A OR LESS LOCATED AT FOOD PREPARATION, FOOD SERVICE OR BEVERAGE COUNTERS SHALL BE PROTECTED BY A READILY ACCESSIBLE GFCI DEVICE PER NEC 210.8(B) (2). GFCI DEVICE MAY BE LOCATED EITHER IN A RECEPTACLE OR CIRCUIT BREAKER. FACE PLATE OF RECEPTACLE CONTROLLED BY GFCI DEVICE SHALL BE MARKED WITH GFCI PROTECTED SYMBOL. 3. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH PULL STRINGS. 4. REFER TO DRAWING A1.5 FOR EQUIPMENT SCHEDULE AND TERMINATION REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR ISLAND DETAILS. 5. ALL EQUIPMENT WITH REMOTE CONDENSERS MOUNTED ON THE ROOF SHALL HAVE 1/2" EMPTY CONDUIT (SEE POWER GENERAL NOTE 3) BETWEEN THE EQUIPMENT AND THE REMOTE CONDENSER FOR CONTROL CIRCUITS. 6. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTIONS, MOUNTING HEIGHTS AND CORD REQUIREMENTS WITH EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. ALL EQUIPMENT SHALL BE LISTED FOR ITS INTENDED USE PER NEC ART. 400.7. 7. PROVIDE HEAT TAPE FOR ALL EXPOSED PIPING. HEAT TAPE TO BE FROM THE SAME CIRCUIT SERVING EQUIPMENT. SEE MECHANICAL SHEETS FOR DETAILS. 8. ELECTRICAL CONVEYANCES FROM BREAKERS TO OUTLET OR FIXTURE SHALL BE ENCLOSED WITHIN CEILING SPACE, FINISHED WALLS OR CABINETRY AND NOT EXPOSED. CODE 6-201.12. 9. PROVIDE POWER TO SMOKE DAMPER WITH DISCONNECT. COORDINATE WITH MECHANICAL FOR LOCATION. CIRCUIT NUMBER IS A-39. POWER GENERAL NOTES 3/16" = 1'-0" 1 ELECTRICAL FLOOR PLAN KEYNOTES 24 (1) 1" EMPTY CONDUIT WITH PULL STRING FOR INTERCOM FROM PANEL DP LOW VOLTAGE SECTION 1 TO CHECKOUT. REFERENCE DP MANUFACTURER INFORMATION. 25 (1) 2" EMPTY CONDUIT WITH PULL STRING FROM PANEL DP LOW VOLTAGE SECTION 1 TO CHECKOUT CABINET. REFERENCE DP MANUFACTURER INFORMATION. 26 WINE RACK RECEPTACLES: REFERENCE MANUFACTURER INSTRUCTION FOR EXACT LOCATION OF RECEPTACLES WITHIN DISPLAY. 27 (1) 2" EMPTY CONDUIT WITH PULL STRING TO MANAGER'S DESK. 28 FUEL ISLAND DISPENSER / FUEL TANK POWER, CONTROL AND MONITORING CONDUIT ENTRANCES. REFERENCE SHEET E1.0, DETAILS 5/E1.1, 6/E1.1 AND FUEL SYSTEM VENDOR DRAWINGS. 29 CONDUIT ENTRY POINT FOR FUEL CANOPY LIGHTING / SIGNAGE AND SITE LIGHTING CONDUIT(S). REFERENCE SHEETS E1.0 AND E1.1. 30 VEEDER ROOT TLS450 MONITOR SYSTEM. PROVIDE (4) 1" CONDUITS WITH PULL STRING STUBBED UP +30" AFF AT MONITOR LOCATION, ROUTED UNDERSLAB TO LOW VOLTAGE CONTROL SECTION 1 IN SWITCHGEAR DP. REFERENCE SWITCHGEAR VENDOR DRAWINGS FOR LOW VOLTAGE SECTION LOCATION. VEEDER ROOT MONITOR CONSOLE TO BE INSTALLED +48" AFF TO CENTER BY PETROLEUM SYSTEMS ELECTRICIAN. COORDINATE EXACT LOCATION WITH PETROLEUM SYSTEMS ELECTRICIAN. KEYNOTES 12 MOUNT RECEPTACLE TO ACCESSIBLE CEILING IN COOLER / BEER CAVE FOR LOW VOLTAGE SIGNAGE. SEAL SLEEVE WITH POLY SILICON CAULKING TO PREVENT MOISTURE AND AIR FROM ENTERING AND DAMAGING THE TRANSFORMER AND LOW VOLTAGE WIRING. 13 PROVIDE JUNCTION BOX WITH DUPLEX RECEPTACLE FOR PLUG IN ABOVE THE CEILING GRID. 14 PROVIDE JUNCTION BOX ABOVE CEILING FOR HARDWIRED ELECTRICAL CONNECTION. 15 COOLER EVAPORATOR. PROVIDE 20A 250V 1P + EQUIPMENT GROUND, FUSIBLE HEAVY DUTY SAFETY SWITCH IN NEMA 3R ENCLOSURE. PROVIDE 2#12 1#12 GND, IN 3/4" CONDUIT. PROVIDE SEAL-OFF DEVICE PER NEC 300.7 AND PROVIDE GROUND FAULT PROTECTION FOR HEAT TRACE PER NEC 427.22. PROVIDE WP GFCI RECEPTACLE FOR MAINTENANCE. 16 CO2 ALARM STROBE JUNCTION BOX. SINGLE GANG JUNCTION BOX MOUNTED 8" BELOW CEILING CENTERED ON DOOR WITH CONDUIT TO ACCESSIBLE BACKROOM CEILING SPACE FOR LOW VOLTAGE COMMUNICATION WIRING BY OTHERS. 17 FREEZER EVAPORATOR. PROVIDE 20A 250V 2P + EQUIPMENT GROUND, FUSIBLE HEAVY DUTY SAFETY SWITCH IN NEMA 3R ENCLOSURE. PROVIDE 2#12 1#12 GND, IN 3/4" CONDUIT. PROVIDE SEAL-OFF DEVICE PER NEC 300.7 AND PROVIDE GROUND FAULT PROTECTION FOR HEAT TRACE PER NEC 427.22. PROVIDE WP GFCI RECEPTACLE FOR MAINTENANCE. 18 PROVIDE FLUSH MOUNT RECEPTACLE IN CEILING FOR WINDOW DISPLAYS. 19 JUNCTION BOX AND RECEPTACLE FOR CO2 MONITOR CONTROL PANEL. CATEGORY 5 CONTROL WIRING TO BE CONCEALED WITHIN WALL. NO EXPOSED WIRING IN SALES AREA. 20 HAND DRYER: INSTALL PER MANUFACTURER INSTRUCTIONS. 21 PROVIDE (1) 2" EMPTY CONDUIT WITH PULL STRING FROM CHECKOUT ISLAND TO CHECKOUT CABINET. 22 PROVIDE (1) 2" EMPTY CONDUIT WITH PULL STRING FROM CHECKOUT ISLAND TO NETWORK RACK. 23 (1) 2" EMPTY CONDUIT WITH PULL STRING FROM CHECKOUT CABINET TO MANAGER'S DESK. KEYNOTES 1 JUNCTION BOX FOR AUTOMATIC FLUSH SENSOR. COORDINATE EXACT MOUNTING HEIGHT WITH MANUFACTURER INSTRUCTIONS AND PLUMBING CONTRACTOR. 2 PROVIDE NEMA L15 SPECIAL OUTLET AND MATCHING CORD/PLUG FOR COMPLETE CONNECTION OF EQUIPMENT. 3 PROVIDE FLUSH RECESSED HUBBELL FLOOR BOX WITH BRASS COVER PLATE FOR POWER TO DISPLAYS AND EQUIPMENT. 4 JUNCTION BOX WITH (1) 3/4" EMPTY CONDUIT TO NETWORK SWITCH IN OFFICE AREA FOR ATM DATA. 5 PROVIDE AND INSTALL CONDUIT(S) UNDER SLAB FROM THE PANELS IN THE BACK OF THE HOUSE TO THE FOOD PREP AREA IN FRONT OF STORE. TRANSITION FROM PVC TO GRC 90 DEGREE ELL TO STUB-UP THROUGH SLAB AND CONTINUE CIRCUIT TO EQUIPMENT RECEPTACLE USING ARMORED FLEX. PROVIDE A MEANS OF MOUNTING FOR RECEPTACLE UNDER THE EQUIPMENT. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH OWNER PRIOR TO INSTALLATION. 6 PROVIDE CEILING MOUNTED RECEPTACLE FOR NEON SIGNAGE AT COLD VAULT. 7 PROVIDE JUNCTION BOX FOR HARD WIRE CONNECTION TO RE-CIRC PUMP AND AQUA-STAT TIMER. PROVIDE MOTOR RATED SWITCH PER 422.31 (C). VERIFY EXACT LOCATION AND MOUNTING HEIGHT PRIOR TO ROUGH-IN. 8 PROVIDE 3/4" CONDUIT UNDER SLAB FROM CASEWORK BACK TO WALL FOR 120V POWER TO FLOOR BOXES. ROUTE IN FIELD TO NEAREST ACCESSIBLE POINT AND MINIMIZE INTERFERENCES. REFER TO ARCHITECTURAL PLANS FOR MORE INFORMATION. 9 PROVIDE SPECIAL OUTLET FOR COMPLETE CONNECTION OF EQUIPMENT. VERIFY EXACT NEMA CONFIGURATION WITH SUPPLED EQUIPMENT. 10 WATER HEATER AT 208V 3PH. PROVIDE 100A 250V 3P+EQUIPMENT GROUND, NON-FUSIBLE DISCONNECT SWITCH INSTALLED IN READILY ACCESSIBLE LOCATION. 11 E.C. SHALL PROVIDE A HEAT TAPE FOR RECEPTACLES. CONNECT TO RECEPTACLE CIRCUIT WITH 2#12, 1#12 GND IN 3/4" CONDUIT. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL CONTRACTOR. NOTE: REFER TO SHEETS A1.5.1 AND A1.5.2 FOR ADDITIONAL EQUIPMENT ELECTRICAL INFORMATION AND REQUIREMENTS. COORDINATE ROUTING OF BRANCH CIRCUITS IN SIPS PANEL WITH VENDOR INSTALLED CHASES OR IN FURRED OUT WALLS. CIRCUITS SHALL NOT BE ROUTED EXPOSED ON SIPS PANELS OR WALLS. MINIMAL CUTTING OF SIPS PANELS FOR RECESSED BOXES OR DEVICES IS ALLOWED. COORDINATE LOCATIONS WITH PANEL MANUFACTURER SECURITY CAMERAS AND MONITORS ARE FURNISHED AND INSTALLED BY OTHERS. CONTRACTOR TO PROVIDE ALL PENETRATIONS AND WIRING IN ACCORDANCE WITH LOCAL CODE. SECURITY CONTRACTOR IS RESPONSIBLE FOR LOW VOLTAGE PERMITTING AND INSPECTIONS. ALL PENETRATIONS IN EXTERIOR WALLS AND WALK-IN COOLERS SHALL BE SEALED PER SPECIFICATIONS. CONTRACTOR TO COORDINATE WITH SECURITY SYSTEM INSTALLER. OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST SD SD J PE C - 5 WP WP WP WP 1 EXTERIOR ROOF ACCESS LADDER E - 2,4,6 E - 8,10,12 ISLAND MERCH. ICE MACHINE ICE MACHINE ICE MACHINE E - 7,9,11 E - 13,15,17 3/4"C,3#10,1#10G 30AS/30AF, NEMA 3R E - 19,21,23 E - 25,27,29 E - 14,16,18 E - 20,22,24 3/4"C,3#10,1#10G 30AS/20AF, NEMA 3R 3/4"C,3#12,1#12G 30AS/20AF, NEMA 3R 3/4"C,3#8,1#10G 60AS/50AF, NEMA 3R 3/4"C,3#10,1#10G 30AS/20AF, NEMA 3R WALK-IN FREEZER WALK-IN COOLER COLD VAULT ZERO ZONE FREEZER B - 19 DP - 7 DP - 8 WP 2 1 3 4 5 4 4 6 6 1"C,3#3,1#8G 4 7 7 3/4"C,3#10,1#10G 30AS/25AF, NEMA 3R 3/4"C,3#10,1#10G 30AS/25AF, NEMA 3R 3/4"C,3#10,1#10G 30AS/25AF, NEMA 3R 1 - 1 1/2"C,3#1/0,1#6G 5 OAU1 RTU1 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E4.0 PROJECT NUMBER: 24212 ROOF POWER PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 3/16" = 1'-0" 1 ROOF POWER PLAN KEYNOTES 1 WP, GFCI WEATHER RESISTANT RECEPTACLE ON ROOF. 2 WP JUNCTION BOX ON ROOF FOR SATELLITE DISH WITH 1" EMPTY CONDUIT TO CASHIER COUNTER LOTTO MACHINE. VERIFY EXACT LOCATION OF SATELLITE DISH IN FIELD. 3 MOUNT PHOTOCELL TO INTERIOR WALL OF PARAPET. ROUTE CONDUIT THROUGH PARAPET WALL TO LIGHTING CONTROL. DETAIL 2/E6.0. 4 ROOF TOP UNIT IS PROVIDED WITH MANUFACTURER FACTORY INSTALLED DISCONNECT AND GFI MAINTENANCE RECEPTACLE. CIRCUIT AS SHOWN. 5 DUCT SMOKE DETECTOR. 6 WP GFCI RECEPTACLE FOR MAINTENANCE. MOUNT ADJACENT TO DISCONNECT. 7 EXTEND CONDUIT AND WIRE TO THERMOSTAT FOR LINE VOLTAGE CONNECTION. COORDINATE WITH MECHANICAL CONTRACTOR. 1. ALL EXTERIOR DEVICES SHALL BE WEATHERPROOF RATED. 2. ALL EQUIPMENT WITH REMOTE CONDENSERS MOUNTED ON THE ROOF SHALL HAVE (1) 1/2" EMPTY CONDUIT BETWEEN THE EQUIPMENT AND THE REMOTE CONDENSER FOR CONTROL CIRCUITS. 3. ROUTE CONDUIT(S) FOR CONDENSERS THROUGH SAME WEATHERPROOF GOOSENECK USED FOR CONDENSATE PIPING - REFER TO DETAIL #2 ON SHEET M1.2.1. 4. SEAL ALL BUILDING PENETRATIONS. 5. HEAT TRACE TO BE PROVIDED IN COLD REGIONS. ROOF POWER GENERAL NOTES OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST J J J J J J J J J J J JJJ J J J J J J J J J J J J J J J J J J J J J J J J IN V SM J JJ J J J S J J J J J J J PE PE PE PE PE PE PE J J J J A B 2 1 a b a b a a a a a b b b b b b ba a b a b b a a a a a a a 1 2 c c c c c c d d dd NL/EM NL/EM NL/EM NL/EM NL/EM NL/EM NL/EM NL/EM NL/EM NL/EM NL/EM NL/EMNL/EM NL/EM 33 3 333 3 3 3 3 3 3 3 3 DAYLIGHT ZONE SECONDARY DAYLIGHT ZONE DAYLIGHT ZONE LIMIT SECONDARY DAYLIGHT ZONE LIMIT DAYLIGHT ZONE SECONDARY DAYLIGHT ZONE DAYLIGHT ZONE SECONDARY DAYLIGHT ZONE A - 17 VIA 'c' & 'd' NL/EM 3 VIA 'a' & 'b' EX e e e A - 30 A - 16 VIA 'e' EX INVERTER A - 33 LOGO SIGN 14'-6" AGL 4 14'-6" AGL 14'-6" AGL 14'-6" AGL 14'-6" AGL14'-6" AGL 14'-6" AGL WP A - 27 A - 21 5 5 A - 14 K J EX W EX L B B B B BB EM EM EM BBBB B B B B EM A A AAE A AE A A AE AA A A A A A C C C CECCE C C C C C C A AE A A AA A A AE A AAA A AE AA AE A A A AAEA DDEDDED AD DE AA K J W 8'-0" AFF 10'-6" AFF A A A b a b AE BB AE LL L LLLLL LL BBB A A A TO INVERTER A - 10 TO FRONT ENTRANCE LIGHTS VIA LIGHTING CONTROLS e e BB NL/EM 3 JJ J JE K K NL/EM 3 WP WP WPWPWP WP WP B 66 AE A a A a 7 VIA LIGHTING CONTROLS SALES FLOOR 107 WALK-IN COOLER 104 BACK ROOM 109 COLD VAULT 105 STORAGE ROOM 103 WALK-IN FREEZER 106 MEN'S RESTROOM 102 CASHIER 108 PREP AREA 110 7 WOMEN'S RESTROOM 101 4 B B 14'-6" AGL WP 14'-6" AGL WP B ON OFF A-30 a CIRCUIT CONTROLLED (TYP.) CONTROL IDENTIFICATION ON OFF A-30 b ON OFF A-17 c ON OFF A-17 d ON OFF A-16 e TS C MULTI-POLE LIGHTING CONTACTOR OR TIME SWITCH TO EXTERIOR FIXTURES TYPE L120V 120V EXTERIOR AUTOMATIC LIGHTING CONTROLS NEUTRAL 120V 120V UNSWITCHED BRANCH CIRCUIT TO EXTERIOR EGRESS FIXTURES TYPE W EMERGENCY BATTERY SWITCHED BRANCH CIRCUIT REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E5.0 PROJECT NUMBER: 24212 LIGHTING PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 3/16" = 1'-0" 1 ELECTRICAL LIGHTING PLAN N.T.S. 2 SWITCHBANK DETAIL N.T.S. 3 EXTERIOR EMERGENCY LIGHTING DETAIL KEYNOTES 1 REFER TO SWITCH BANK DETAIL 2/E5.0 FOR SWITCHING OF SALES FLOOR LIGHTING. VERIFY FINAL LOCATION WITH OWNER. 2 REFER TO ARCHITECTURAL SHEETS FOR ACCESS PANEL FOR SIGNAGE IN THIS SOFFIT AREA. 3 PROVIDE WITH EMERGENCY BATTERY BACK-UP BALLAST - BODINE B50. 4 PROVIDE HIGHLITES EMERGENCY BATTERY PACK - PCF 250 - BLACK IN COLOR (SEE DETAIL 3/E5.0) 5 PROVIDE TEMPERATURE SEAL / FIRE STOP FOR ALL CONDUITS AND HOME RUNS IN THESE AREAS PER NEC 300.7. 6 RESTROOM OCCUPANCY SENSOR: SET SENSOR FOR 20 MINUTE TIME DELAY 7 ROUTE CIRCUIT VIA PHOTOCELL CONTROLLED CONTACTOR. REFERENCE DETAIL 2/E6.0. A. COORDINATE ALL WORK WITH OTHER TRADES AND THE PROJECT MANAGER. B. VERIFY LOCATION AND MOUNTING HEIGHT OF ALL LIGHT FIXTURES WITH THE ARCHITECT / OWNER PRIOR TO ROUGH-IN. C. THE EXIT, EMERGENCY AND NIGHT LIGHT FIXTURES SHALL NOT BE SWITCHED. D. RGS CONDUIT SHALL BE USED IN ALL EXTERIOR LOCATIONS. E. MINIMUM CONDUIT SIZE SHALL BE 1/2". F. MINIMUM WIRE SIZE SHALL BE #12 THHN/THWN CU. G. ALL EXTERIOR LIGHT FIXTURES SHALL BE CONTROLLED VIA PHOTOCELL. REFERENCE DETAIL 2/E6.0. H. REFER TO THE PANEL SCHEDULES ON SHEETS E7.0 AND E7.1 FOR LOAD DESIGNATIONS. THERE SHALL BE NO SHARED NEUTRALS. I. CONDUIT(S) SHALL NOT BE ROUTED EXPOSED ON ANY EXTERIOR OR INTERIOR WALL. J. ALL EXTERIOR DEVICES SHALL BE WEATHERPROOF RATED. K. REFER TO SHEET E0.0 FOR THE LIGHT FIXTURE SCHEDULE. L. PROVIDE STAINLESS STEEL SWITCH COVERS FOR ALL CUSTOMER ACCESSIBLE AREAS. (RESTROOMS, HALLWAY, COOLER, SALES AREA). M. ALL EMERGENCY EQUIPMENT SHALL BE LISTED TO UL924 AND BE INSTALLED PER NEC 700. N. OCCUPANCY SENSORS SHALL BE SET TO MAXIMUM DELAY PER MANUFACTURER INSTRUCTIONS. LIGHTING GENERAL NOTES OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E5.1 PROJECT NUMBER: 24212 LIGHTING COMPLIANCE REPORT CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST 20/1 L N A-12 NC 'EPO' -EMERGENCY POWER OFF SWITCH A-4 A-8 A-10 A-33 A-5 A-20 A-22 SPARE LTG MONUMENT SIGN LTG MONUMENT SIGN LTG EXTERIOR LTG FRONT LOGO SIGN LTG CANOPY EYEBROW LTG PARKING LOT LTG PARKING LOT SPARE NC PHOTOCELL "TORK" 2100 SERIES, MOUNT ON ROOF, AIM NORTH A-9 A-11 A-13 A-15 TO CANOPY LIGHTING TO CANOPY LIGHTING SPARE SPARE A-1 A-3 SPARE CANOPY SIGN CANOPY SIGN SPARE REFERENCE VENDOR EQUIPMENT DRAWINGS FOR EXACT CONTROL WIRING DIAGRAMS AND CONTRACTOR WIRED EQUIPMENT 30-AMP, 4-POLE, 250V, ELECTRICALLY HELD LIGHTING CONTACTOR FACTORY INSTALLED IN SWITCHGEAR DP, TYP OF 4. REFERENCE VENDOR DRAWINGS. #3/0 CU. EQUIP. BOND N G #3/0 CU. MAIN BONDING JUMPER #3/0 CU. TO BUILDING STEEL #6 BARE CU. TO 3/8"x10' GROUND ROD TRIAD #4 CU. UFER GROUND #3 CU. BOND TO METALLIC COLD WATER PIPING SYSTEMS / FIRE SPRINKLER / COMPRESSED AIR PIPING #3 CU. BOND TO METALLIC GAS PIPING SYSTEMS PORTABLE GENERATOR (NOT PROVIDED) MCT. C-STORE SERVICE ENTRANCE DISCONNECT 1,000A, 120/208V-3PH-4W, 65K AIC RMS, NEMA 3R REFER TO GROUND DETAIL 3/E6.0. MAIN BONDING JUMPER #3/0 AWG CU 1000A F2X 1000A MAIN BREAKER AND GENERATOR BREAKER FURNISHED WITH KIRK-KEY INTERLOCK, REF VENDOR EQUIPMENT DRAWINGS PORTABLE GENERATOR CONNECTION TO UTILITY TRANSFORMER. TRANSFORMER SHALL BE PROVIDED AND SIZED BY UTILITY COMPANY. PROVIDE 3 -3"C, 4-400KCMIL EACH PER 2023 NEC 110.24 SERVICE EQUIPMENT LEGIBLY MARKED IN THE FIELD WITH MAXIMUM AVAILABLE FAULT CURRENT AND INCLUDE THE DATE THE FAULT CURRENT CALCULATION WAS PERFORMED ON EQUIPMENT. NOTE: CONTRACTOR SHALL FURNISH INSTALLATION MANUAL FOR EACH EQUIPMENT SUCH AS PANELBOARD, CONTROL EQUIPMENT, ETC.SERIES RATING GENERAL NOTES 1.THE MOTOR CONTRIBUTION TO THE FAULT CURRENT MEETS THE 1% CRITERIA STATED IN NEC 240.86(C) 2.NO DESIGN CHANGES MAY BE MADE TO THE SYSTEM WITHOUT THE PRIOR APPROVAL OF THE DESIGN ELECTRICAL ENGINEER AND THE ELECTRICAL INSPECTOR. ONE-LINE KEYNOTES 1.THIS SERVICE IS A SERIES RATED SYSTEM: 2-TIER 65/10. ALL SERVICE ENTRANCE EQUIPMENT SYSTEM COMPONENTS SHALL BE RATED 65K, WITH SERIES RATED DOWNSTREAM. 2.CONTRACTOR SHALL LABEL SERVICE ENTRANCE EQUIPMENT "CAUTION -SERIES RATED SYSTEM (65). 65,000 AMPS AVAILABLE IDENTIFIED REPLACEMENT COMPONENT REQUIRED." IN ACCORDANCE WITH NEC 110.22. 3.CONTRACTOR SHALL LABEL PANEL(S) "CAUTION -SERIES RATED SYSTEM ("X"). "X" AMPS AVAILABLE IDENTIFIED REPLACEMENT COMPONENT REQUIRED IN ACCORDANCE WITH NEC 110.22". (REFER TO SHORT CIRCUIT CALCULATIONS FOR ACTUAL AMPS TO BE LABELED). 4.CIRCUIT BREAKERS SHALL BE A BOLT-ON TYPE U.L. LISTED SERIES RATED COMBINATION WITH THE BREAKERS AT DISTRIBUTION PANEL "DP". 5.REFER TO E4.0 ROOF POWER PLAN FOR WIRE AND CONDUIT SIZE FOR ROOF TOP UNITS. 6.MAXIMUM CIRCUIT BREAKER HEIGHT EQUAL TO 6'-7" AFF OR AFG. 1 3 -3"C, 4-400KCMIL, 1#2/0 GR EACH METER / CT CABINET PER UTILITY REQUIREMENTS 3 -3"C, 4-400KCMIL, EACH #12CU. (8-FT MIN.) TIMECLOCK AND LTG. CONTROL RELAYS F9X NOTE: FEEDERS FROM PANEL DP TO PANEL BOARDS SHOWN DASHED ARE FACTORY INSTALLED. REFERENCE SWITCHGEAR VENDOR DRAWINGS. 6KVA POWER CONDITIONER SECTION #2 SECTION #3 SECTION #4 47" F4 F8 F5 F7 PANEL 'G' PANEL 'B' PANEL PANEL 'E' 208/120V 3PH, 4W 208/120V 3PH, 4W 208/120V 3PH, 4W 208/120V 3PH, 4W 24" SECTION #1 47" F3-F8 FUEL CONTROLS F3 PANEL 'A' 208/120V 3PH, 4W F6 PANEL 'D' 208/120V 3PH, 4W 'C' 47" F10X 'DP' DISTRIBUTION PANELTC C 2 3 4 3 4 3 4 3 4 6 PNL 'C' PANEL 'DP' 225/3 225/3 225/3 125/3 30/3 225/3225/3 90/3 5 5 PNL 'A' PNL 'B' PNL 'G' RTU1 PNL 'E' PNL 'D' OAU1 SPD150/3 RS E -1 RS E -1 SP D ------ FUEL CONTROLS F10 PANEL 'U' 240/120V LIGHTING CONTACTOR CONTROLS F1X U1 X REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E6.0 PROJECT NUMBER: 24212 CALCULATIONS AND SCHEMATICS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA N.T.S. 2 LIGHTING CONTROL DIAGRAM N.T.S. 3 GROUNDING DETAIL - 1000 AMP SERVICE N.T.S. 1 RISER DIAGRAM OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E7.0 PROJECT NUMBER: 24212 PANEL SCHEDULES CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 1. TERMINATE GROUND ON ISOLATED GROUND BUS. 2. INSTALL LOCKING DEVICE ON BREAKER PER NEC (LOCK-OFF FOR MAINTENANCE). 3. INSTALL LOCKING DEVICE ON BREAKER PER NEC (LOCK-ON FOR CRITICAL LOAD). 4. GFI BREAKER FOR PERSONNEL PROTECTION (5MA). 5. REFER TO ONE-LINE DIAGRAM FOR CONDUCTOR SIZES. 6. PROVIDE LOCK-OFF DEVICE TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS PER NEC. 7. FIRE ALARM CIRCUIT. PROVIDE RED MARKING AND LABEL "FIRE ALARM CIRCUIT CONTROL" ON BREAKER. 8. OPTIONAL EQUIPMENT: REVISE TO FILLER SPACE IF NOT USED ON SITE. 9. FACTORY INSTALLED WIRING IN UNITIZED SWITCHGEAR. PANELBOARD CIRCUIT NOTES 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 11.55 125.00% 14.44 Spare Capacity Percent:57 9 Computer Outlets 0.00 0.00% 0.00 Spare Capacity:97 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.00 0.00% 0.00 5 Kitchen (Commercial) 0.00 0.00% 0.00 4 Motors 0.00 0.00% 0.00 Total Est. Demand:128 A 3 Special Loads 24.30 100.00% 24.30 Total Conn.:117 A 2 Receptacles 1.56 100.00% 1.56 Total Est. Demand:46.17 1 Lighting - Continuous 4.69 125.00% 5.87 Total Conn. Load:42.10 0 Lighting - Non-Continuous 0.00 0.00% 0.00 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:117 A 123 A 112 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:13.98 14.69 13.44 kVA 41 -- FILLER SPACE -- -- 1 -- 8.00 42 39 2 SMOKE DAMPER POWER 3,7 20 A 1 0.18 8.00 40 37 2 IRRIGATION CONTROLS 20 A 1 0.30 8.00 3 90 A WATER HEATER 3 38 35 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 36 33 10 CIRCLE K FRONT LOGO SIGN 20 A 1 0.60 -- 1 -- -- FILLER SPACE -- 34 31 -- FILLER SPACE -- -- 1 -- 0.18 1 20 A DOOR CHIME 2 32 29 -- SPARE -- 20 A 1 0.00 1.80 1 20 A LTG. SALES FLOOR 1 30 27 10; 1 LTG. RESTROOMS / STOCKROOM 20 A 1 0.69 0.08 1 20 A LTG/HTR COLD VAULT DOORS 1 28 25 2 LED FRAME - COFFEE 20 A 1 0.15 0.00 1 20 A -- SPARE -- 26 23 2 LED FRAME - FOOD 20 A 1 0.10 0.60 1 20 A LTG/HTR WALK-IN CLR DOORS 1 24 21 10; 1 LTG. COOLER / COLD VAULT 20 A 1 0.15 0.62 1 20 A LTG. EXTERIOR PARKING - POLES 10 22 19 2 LTG. COOLER SIGNS 20 A 1 0.65 0.62 1 20 A LTG. EXTERIOR PARKING - POLES 10 20 17 1 LIGHTING CASHIER / PREP 20 A 1 0.53 0.00 1 20 A -- SPARE -- 18 15 0.60 0.48 1 20 A LTG. COFFEE & DRINKS 1 16 13 10 FUEL CANOPY LIGHTING 20 A 2 0.60 0.35 1 20 A LTG. BACK ROOM / OFFICE 10; 1 14 11 0.60 0.30 1 20 A MISC. - LTG CONTACTOR 3 12 9 10 FUEL CANOPY LIGHTING 20 A 2 0.60 0.50 1 20 A LTG. EXTERIOR BUILDING 10; 1 10 7 -- FILLER SPACE -- -- 1 -- 0.96 1 20 A LTG. - MONUMENT SIGN - LOGO 10 8 5 10 FUEL CANOPY EYEBROW 20 A 1 0.54 0.96 1 20 A LTG. - MONUMENT SIGN - PRICE 10 6 3 10 FUEL CANOPY SIGN 20 A 1 1.20 0.96 1 20 A LTG. - MONUMENT SIGN - LOGO 10 4 1 10 FUEL CANOPY SIGN 20 A 1 1.20 0.96 1 20 A LTG. - MONUMENT SIGN - PRICE 10 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B C Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, installed by EC Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Series Neutral Busbar:100% A System:3Ø, 4W A.I.C. Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Mains Type:M.L.O.Busbar Material:CUPANELBOARD Bus Rating:225 A Main Rating Upstream:225 A Location:DIST. DP 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 0.00 0.00% 0.00 Spare Capacity Percent:43 9 Computer Outlets 0.00 0.00% 0.00 Spare Capacity:127 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.00 0.00% 0.00 5 Kitchen (Commercial) 22.54 65.00% 14.65 4 Motors 0.21 100.00% 0.21 Total Est. Demand:98 A 3 Special Loads 9.90 100.00% 9.90 Total Conn.:120 A 2 Receptacles 10.21 98.97% 10.11 Total Est. Demand:35.19 1 Lighting - Continuous 0.26 125.00% 0.33 Total Conn. Load:43.12 0 Lighting - Non-Continuous 0.00 0.00% 0.00 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:134 A 104 A 127 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:15.75 12.51 14.85 kVA 41 2.17 0.26 1 20 A H002 / H005 HOT DOG ROLLER 5 42 39 2.17 0.32 1 20 A H101 / H002 SNEEZE GUARD 5 40 37 5 H211 UNOX SPEEDPRO OVEN (OPTIONAL)8 20 A 3 2.17 -- 1 -- -- FILLER SPACE -- 38 35 2 B503 REC. CO2 DETECTION 3 20 A 1 0.18 1.54 1 20 A H001 HOT DOG ROLLER 5 36 33 5 H303 U.C. MICROWAVE 20 A 1 1.50 -- 1 -- -- FILLER SPACE -- 34 31 5 H303 U.C. MICROWAVE 20 A 1 1.50 1.54 1 20 A H001 / H005 HOT DOG ROLLER 5 32 29 2.17 -- 1 -- -- FILLER SPACE -- 30 27 2.17 -- 1 -- -- FILLER SPACE -- 28 25 5 H211 UNOX SPEEDPRO OVEN 20 A 3 2.17 -- 1 -- -- FILLER SPACE -- 26 23 2 C101 2 EA.-2 VALVE CREAMER 20 A 1 0.66 1.20 1 20 A B006 BEVERAGE COOLER 5 24 21 4 R306 SCA REFRG CASE FANS/HTRS 20 A 1 0.21 0.78 1 20 A C201 COUNTERTOP ICE MAKER 2 22 19 3 DUCT SMOKE DETECTORS 3,7 20 A 1 0.30 0.14 1 20 A R306 SCA REFRG CASE LIGHTS 1 20 17 5 R207 27" U.C. FRIDGE 20 A 1 0.48 0.18 1 20 A 4,8 WATER COOLERS 2 18 15 2 REC. BIB EQ B601, B602, B603 20 A 1 1.20 0.12 1 20 A RI FRZR & COLD VLT OVALS LED 1 16 13 2.40 2.40 14 11 3 B301 4-HEAD FROSTED VIPER 30 A 2 2.40 2.40 2 30 A B301 4-HEAD FROSTED VIPER 3 12 9 2 B003 ICE TEA CURTIS 20 A 1 1.65 1.65 1 20 A B003 ICE TEA CURTIS 2 10 7 2 RECS. GENERAL BACK RM 4 20 A 1 0.72 1.20 1 20 A B006 BEVERAGE COOLER 5 8 5 2 B001 12-HEAD SODA FOUNTAIN 20 A 1 0.62 0.60 1 20 A B101 ICE MAKER 2 6 3 2 B001 12-HEAD SODA FOUNTAIN 20 A 1 0.62 0.13 1 20 A B102 ICE MAKER 2 4 1 2 B001 12-HEAD SODA FOUNTAIN 20 A 1 0.62 0.60 1 20 A B101 ICE MAKER 2 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B C Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, installed by EC Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Series Neutral Busbar:100% B System:3Ø, 4W A.I.C. Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Mains Type:M.L.O.Busbar Material:CUPANELBOARD Bus Rating:225 A Main Rating Upstream:225 A Location:DIST. DP 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 0.00 0.00% 0.00 Spare Capacity Percent:39 9 Computer Outlets 0.00 0.00% 0.00 Spare Capacity:138 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.00 0.00% 0.00 5 Kitchen (Commercial) 10.99 90.00% 9.89 4 Motors 2.80 100.00% 2.80 Total Est. Demand:87 A 3 Special Loads 0.00 0.00% 0.00 Total Conn.:112 A 2 Receptacles 26.15 69.12% 18.08 Total Est. Demand:31.45 1 Lighting - Continuous 0.00 0.00% 0.00 Total Conn. Load:40.49 0 Lighting - Non-Continuous 0.54 125.00% 0.68 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:117 A 101 A 123 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:13.83 12.14 14.52 kVA 41 2.28 0.36 1 20 A REC. POS 2 42 39 2.28 0.72 1 20 A REC. POS 2 40 37 5 H201 COMBI OVEN 25 A 3 2.28 0.36 1 20 A REC ISLAND POS 2 38 35 2 REC. AT PIZZA PREP. STATION 4 20 A 1 0.18 0.72 1 20 A RECS. CONVENIENCE OUTLET 2 36 33 2 H101,H102,H104 COLD WELL REC 20 A 1 0.54 0.36 1 20 A RECS. CONVENIENCE OUTLET 2 34 31 0 LTG. LED CONTROL / REC. 20 A 1 0.54 0.18 1 20 A REC. CONVENIENCE OUTLET 2 32 29 4 WATER / AIR FILL STATION 20 A 1 1.80 1.00 1 20 A RECIRC. PUMP / AQUA STAT 4 30 27 2 RECS. PREP CONVENIENCE 20 A 1 0.36 -- 1 -- -- FILLER SPACE -- 28 25 2 R401 6' NOVELTY CASE 20 A 1 1.80 1.35 26 23 5 H206 HATCO FSD-2 20 A 1 1.44 1.35 2 20 A 8 H209 FLEXESERVE 1000 (OPTIONAL) 5 24 21 2 WINE RACK RECEPTS 20 A 1 0.72 1.67 22 19 2 R201 WINE REFRIG 20 A 1 0.65 1.67 2 30 A R203 4DR REACH-IN FREEZER 2 20 17 2 HOT BOX - BACKFLOW PREVENTOR 8 20 A 1 1.20 -- 1 -- -- FILLER SPACE -- 18 15 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 16 13 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 14 11 2 C004 NITRO BREWER 20 A 1 0.72 0.72 1 20 A C005 NITRO BREWER 2 12 9 2 FROSTER, POLAR POP BACKGRND 20 A 1 0.36 1.80 1 20 A C002 5-HEAD CAPPUCCINO 2 10 7 -- SPARE -- 20 A 1 0.00 1.66 8 5 2 ROOF RECEPTACLES 20 A 1 1.08 1.66 2 20 A C001 COFFEE BREWER 2 6 3 1.66 1.66 4 1 2 C001 COFFEE BREWER 20 A 2 1.66 1.66 2 20 A C001 COFFEE BREWER 2 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B C Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, installed by EC Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Series Neutral Busbar:100% C System:3Ø, 4W A.I.C. Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Mains Type:M.L.O.Busbar Material:CUPANELBOARD Bus Rating:225 A Main Rating Upstream:225 A Location:DIST. DP 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 0.36 125.00% 0.45 Spare Capacity Percent:31 9 Computer Outlets 1.20 100.00% 1.20 Spare Capacity:155 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.50 100.00% 0.50 5 Kitchen (Commercial) 3.04 90.00% 2.74 4 Motors 7.75 100.00% 7.75 Total Est. Demand:70 A 3 Special Loads 1.84 100.00% 1.84 Total Conn.:72 A 2 Receptacles 11.27 94.36% 10.64 Total Est. Demand:25.12 1 Lighting - Continuous 0.00 0.00% 0.00 Total Conn. Load:25.97 0 Lighting - Non-Continuous 0.00 0.00% 0.00 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:67 A 72 A 78 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:8.07 8.57 9.32 kVA 41 3.84 1.20 1 20 A M104 LOTTERY VENDING MACHINE 2 42 39 2; 9 PANEL U VIA 6KVA POWER CONDITIONER 9 40 A 2 2.22 1.35 40 37 3 WOMENS HAND DRYER 2 20 A 1 0.92 1.35 2 20 A 8 H209 FLEXESERVE 1000 (OPTIONAL) 5 38 35 3 MENS HAND DRYER 2 20 A 1 0.92 -- 1 -- -- FILLER SPACE -- 36 33 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 34 31 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 32 29 0.05 0.77 1 20 A 2,8 FF-3 AIR CURTAIN 4 30 27 5 H202 VENTLESS HOOD 20 A 2 0.05 0.77 1 20 A 2,8 FF-2 AIR CURTAIN 4 28 25 2 REC. GONDOLA FLOOR 20 A 1 0.36 1.53 1 20 A 2,8 FF-1 AIR CURTAIN 4 26 23 6; 2 WALK-IN FRZR DOOR HEAT 20 A 1 0.68 -- 1 -- -- FILLER SPACE -- 24 21 4 WALK IN COOLER EVAPS 20 A 1 1.44 -- 1 -- -- FILLER SPACE -- 22 19 2 M001 GONDLOA FLOOR RECS. 20 A 1 0.36 -- 1 -- -- FILLER SPACE -- 20 17 2 M001 GONDOLA FLOOR RECS. 20 A 1 0.72 -- 1 -- -- FILLER SPACE -- 18 15 2 GONDOLA FLOOR RECS. 20 A 1 0.36 0.18 1 20 A 4,8 M105 ICE MERCHANDISER 2 16 13 -- SPARE -- 20 A 1 0.00 0.18 1 20 A 4,8 M102 WATER DISPENSER 2 14 11 2 CEILING RECEPTACLES 20 A 1 0.18 0.36 1 20 A GONDOLA FLOOR RECS. 2 12 9 10 H401 EURO. BAKERY CASE 20 A 1 0.36 0.18 1 20 A FRONT WALL GONDOLA 2 10 7 2 REC. RESTROOMS 20 A 1 0.18 0.48 1 20 A COLD VAULT EVAP 4 8 5 2 REC. SHOW WINDOW 20 A 1 0.36 0.24 1 20 A R202 27" U.C. FREEZER 5 6 3 2 R206 UNDER COUNTER REFRIG 4 20 A 1 0.28 1.38 4 1 2 CIGARETTE BACK BAR RECS. 20 A 1 1.33 1.38 2 20 A BOOSTER PUMP 4 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B C Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, Installed by EC Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Series Neutral Busbar:100% D System:3Ø, 4W A.I.C. Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Mains Type:M.L.O.Busbar Material:CUPANELBOARD Bus Rating:225 A Main Rating Upstream:225 A Location:DIST. DP 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 0.00 0.00% 0.00 Spare Capacity Percent:66 9 Computer Outlets 0.00 0.00% 0.00 Spare Capacity:76 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.00 0.00% 0.00 5 Kitchen (Commercial) 0.00 0.00% 0.00 4 Motors 52.32 100.00% 52.32 Total Est. Demand:149 A 3 Special Loads 0.00 0.00% 0.00 Total Conn.:149 A 2 Receptacles 1.20 100.00% 1.20 Total Est. Demand:53.52 1 Lighting - Continuous 0.00 0.00% 0.00 Total Conn. Load:53.52 0 Lighting - Non-Continuous 0.00 0.00% 0.00 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:149 A 154 A 145 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:17.78 18.38 17.36 kVA 41 2 REC. BITCOIN ATM 20 A 1 0.24 0.36 1 20 A SELF CHECK DRN RECEPT 2 42 39 2 REC. ATM 20 A 1 0.24 0.36 1 20 A SELF CHECK DRN RECEPT 2 40 37 -- SPARE -- 20 A 1 0.00 -- 1 -- -- FILLER SPACE -- 38 35 -- SPARE -- 20 A 1 0.00 -- 1 -- -- FILLER SPACE -- 36 33 1.02 -- 1 -- -- FILLER SPACE -- 34 31 4 WALK-IN FREEZER EVAP 15 A 2 1.02 -- 1 -- -- FILLER SPACE -- 32 29 1.80 -- 1 -- -- FILLER SPACE -- 30 27 1.80 -- 1 -- -- FILLER SPACE -- 28 25 4 COLD VAULT CONDENSER 20 A 3 1.80 -- 1 -- -- FILLER SPACE -- 26 23 1.92 1.80 24 21 1.92 1.80 22 19 4 ZERO ZONE FRZR CONDENSER 20 A 3 1.92 1.80 3 20 A WALK-IN FREEZER CONDENSER 4 20 17 2.51 2.55 18 15 2.51 2.55 16 13 4 R306 REF. ISLAND MERCHDSR 30 A 3 2.51 2.55 3 50 A WALK-IN CLR 17DR CONDENSER 4 14 11 2.40 1.89 12 9 2.40 1.89 10 7 4 B202 ICE MACHINE CONDENSER 25 A 3 2.40 1.89 3 25 A B201 ICE MACHINE CONDENSER 4 8 5 -- FILLER SPACE -- -- 1 -- 1.89 6 3 -- FILLER SPACE -- -- 1 -- 1.89 4 1 -- FILLER SPACE -- -- 1 -- 1.89 3 25 A B201 ICE MACHINE CONDENSER 4 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B C Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, installed by GC Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Fully Neutral Busbar:100% E System:3Ø, 4W A.I.C. Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Mains Type:M.L.O.Busbar Material:CUPANELBOARD Bus Rating:225 A Main Rating Upstream:225 A Location:DIST. DP 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 0.00 0.00% 0.00 Spare Capacity Percent:39 9 Computer Outlets 0.00 0.00% 0.00 Spare Capacity:77 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.00 0.00% 0.00 5 Kitchen (Commercial) 0.00 0.00% 0.00 4 Motors 13.75 100.00% 13.75 Total Est. Demand:48 A 3 Special Loads 2.37 100.00% 2.37 Total Conn.:48 A 2 Receptacles 1.26 100.00% 1.26 Total Est. Demand:17.38 1 Lighting - Continuous 0.00 0.00% 0.00 Total Conn. Load:17.38 0 Lighting - Non-Continuous 0.00 0.00% 0.00 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:55 A 45 A 47 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:6.53 5.46 5.64 kVA 41 2 DISTRIBUTION BOX (E3) 20 A 1 0.36 0.01 42 39 2 INTERCOM CONTROLLER (E2) 20 A 1 0.36 0.01 40 37 3 VEEDER ROOT (E1) 20 A 1 0.24 0.01 3 30 A 9 SPD 3 38 35 2 SPARE ELECTRONICS 20 A 1 0.36 -- 1 -- -- SWITCHED NEUTRAL -- 36 33 2 E-STOP CONTROL PWR 9 15 A 1 0.18 0.26 1 20 A MISC. - DIESEL DISPENSER #2 3 34 31 -- SWITCHED NEUTRAL -- -- 1 -- -- 1 -- -- SWITCHED NEUTRAL -- 32 29 -- FILLER SPACE -- -- 1 -- 0.26 1 20 A MISC. - DIESEL DISPENSER #1 3 30 27 -- FILLER SPACE -- -- 1 -- -- 1 -- -- SWITCHED NEUTRAL -- 28 25 -- FILLER SPACE -- -- 1 -- 0.26 1 20 A MISC. - DISPENSER #7 3 26 23 -- FILLER SPACE -- -- 1 -- -- 1 -- -- SWITCHED NEUTRAL -- 24 21 -- FILLER SPACE -- -- 1 -- 0.26 1 20 A MISC. - DISPENSER #6 3 22 19 1.38 -- 1 -- -- SWITCHED NEUTRAL -- 20 17 4 SUBMRG. 2HP PUMP DIESEL 20 A 2 1.38 0.26 1 20 A MISC. - DISPENSER #5 3 18 15 1.38 -- 1 -- -- SWITCHED NEUTRAL -- 16 13 4 SUBMRG. 2HP PUMP SUL 20 A 2 1.38 0.26 1 20 A MISC. - DISPENSER #4 3 14 11 1.38 -- 1 -- -- SWITCHED NEUTRAL -- 12 9 4 SUBMRG. 2HP PUMP CK CHOICE 20 A 2 1.38 0.26 1 20 A MISC. - DISPENSER #3 3 10 7 1.38 -- 1 -- -- SWITCHED NEUTRAL -- 8 5 4 SUBMRG. 2HP PUMP REGULAR 20 A 2 1.38 0.26 1 20 A MISC. - DISPENSER #2 3 6 3 1.38 -- 1 -- -- SWITCHED NEUTRAL -- 4 1 4 SUBMRG. 2HP PUMP REGULAR 20 A 2 1.38 0.26 1 20 A MISC. - DISPENSER #1 3 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B C Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, installed by EC Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Fully Neutral Busbar:100% G System:3Ø, 4W A.I.C. Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Mains Type:M.L.O.Busbar Material:CUPANELBOARD Bus Rating:125 A Main Rating Upstream:225 A Location:DIST. DP OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST FAULT CURRENT CALCULATIONS THE FOLLOWING CALCULATIONS ARE BASED ON THE "POINT-BY-POINT" METHOD WHERE: Isc = Isc x M M= 1/(1+f)f =1.73 x L x I XFMR:IP(sca)= IP(sca)x Vp x%Z IS(sca)=Vp x M x IS(sca) C x E x n 100,000 x KVA Vs(ALL CALCULATIONS UTILIZE COPPER CONDUCTORS) Source Fault Panel /(Fault Source I Conduit X'FMR X'FMR Point Transformer Point)(amps)Type Wire/Bus Size 'C' value E (volts) L (length)KVA Z f M Isc F1 SERVICE DISC 65,000 F2 DIST. DP F1 M 3 Set(s) of 400 KCM 20,566 208 5 0.037 0.96 53,308 F3 PANEL 'A' F2 1 Set(s) of 4/0 15,082 208 3 F4 PANEL 'B' F2 1 Set(s) of 4/0 208 5 F5 PANEL 'C' F2 1 Set(s) of 4/0 208 F6 PANEL 'D' F2 1 Set(s) of 4/0 208 F7 PANEL 'G' F2 1 Set(s) of 1 7,293 208F8 LTG. CONTACT F3 48,983 1 Set(s) of 12 617 208 8 5.289 0.16 7,789 PANEL 'U' F6 Set(s) of 8 1,557 208 3 0.786 0.56 27,427 F9 48,983 1F10 PANEL 'E' F2 208 0.921Set(s) of 4/0 M M M M M M M M 55,298 55,298 0.088 0.92 0.147 0.87 0.92 0.92 46,470 0.85 45,077 48,983 15,082 15,082 15,082 15,082 3 3 3 3 0.183 U1 UTILITY XFRM 65,000 65,000 U1 M 3 Set(s) of 208 20 0.176 0.85400 KCM 20,566 53,308 0.088 0.088 0.088 48,983 48,983 48,983 53,308 53,308 53,308 53,308 53,308 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY E7.1 PROJECT NUMBER: 24212 PANEL SCHEDULES CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA LHO SAG SAG JCA 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 11.91 125.00% 14.89 Spare Capacity Percent:76 9 Computer Outlets 1.20 100.00% 1.20 Spare Capacity:243 A 7 Cooling 0.00 0.00% 0.00 6 Heating 0.50 100.00% 0.50 5 Kitchen (Commercial) 36.58 65.00% 23.78 4 Motors 156.10 100.00% 156.10 Total Est. Demand Current:757 A 3 Special Loads 38.44 100.00% 38.44 Total Conn. Current:838 A 2 Receptacles 51.66 59.68% 30.83 Total Est. Demand:272.60 1 Lighting - Continuous 4.95 125.00% 6.19 Total Conn. Load:301.88 0 Lighting - Non-Continuous 0.54 125.00% 0.68 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Circuit Numbering By Pole Position Demand Loads May Vary From Connected Loads Because of Demand Factors 857 A 818 A 851 A Amps 102.38 98.18 101.56 kVA 10 3 SPD 9 30 A 3 0.01 0.01 0.01 9 -- FILLER SPACE -- 3 -- -- -- 8 4 RTU 1 150 A 3 15.97 15.97 15.97 7 4 OAU 1 90 A 3 10.45 10.45 10.45 6 2; 4; 3 PANEL G 9 125 A 3 6.53 5.46 5.64 5 2; 4 PANEL E 9 225 A 3 17.78 18.38 17.36 4 6; 2; 4; 10; 5; 3; 9 PANEL D 9 225 A 3 8.07 8.57 9.32 3 2; 4; 5; 0 PANEL C 9 225 A 3 13.83 12.14 14.52 2 2; 4; 5; 1; 3 PANEL B 9 225 A 3 15.75 12.51 14.85 1 2; 10; 1; 3 PANEL A 9 225 A 3 13.98 14.69 13.44 CCT No.Load Codes Load Description Notes Brkr Size Poles A B C Remarks Furnished by Owner, installed by EC Feed Thru Lugs:No Terminations:75°C CU Sections:4 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-On IG Ground Busbar:No Mounting:Cabinet Fully/Series:Fully Neutral Busbar:100% DP System:3Ø, 4W Aic Rating:65,000 A Ground Busbar:Yes Voltage:208Y/120 V Main Type:M.L.O.Busbar Material:CUSWITCHBOARD Bus Rating:1000 A Main Rating Upstream:1000 A Location:DIST. DP 1. TERMINATE GROUND ON ISOLATED GROUND BUS. 2. INSTALL LOCKING DEVICE ON BREAKER PER NEC (LOCK-OFF FOR MAINTENANCE). 3. INSTALL LOCKING DEVICE ON BREAKER PER NEC (LOCK-ON FOR CRITICAL LOAD). 4. GFI BREAKER FOR PERSONNEL PROTECTION (5MA). 5. REFER TO ONE-LINE DIAGRAM FOR CONDUCTOR SIZES. 6. PROVIDE LOCK-OFF DEVICE TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS PER NEC. 7. FIRE ALARM CIRCUIT. PROVIDE RED MARKING AND LABEL "FIRE ALARM CIRCUIT CONTROL" ON BREAKER. 8. OPTIONAL EQUIPMENT: REVISE TO FILLER SPACE IF NOT USED ON SITE. 9. FACTORY INSTALLED WIRING IN UNITIZED SWITCHGEAR. PANELBOARD CIRCUIT NOTESGROUND WIRE SIZING CHART BRKR AMPS PHASE WIRE SIZE GROUND 12 10 8 6 4 15-20 12 10 8 6 4 PHASE GROUND 10 8 6 4 25-30 10 8 6 4 PHASE GROUND 8 6 4 3 2 35-50 10 8 4 4 4 PHASE GROUND 6 4 3 2 1 60 10 6 6 4 4 PHASE GROUND 6 4 3 2 1 70 8 4 4 3 2 PHASE GROUND 4 3 2 1 1/0 80-90 8 6 4 4 3 PHASE GROUND 3 2 1 1/0 2/0 100 8 6 4 4 3 PER NEC 250.122(B) 3 3 20A WIRE SIZING SCHEDULE 385 FT. 770 FT. 255 FT. ALL WIRE SIZES SHOWN ON PANEL SCHEDULES ARE INTENDED TO BE MINIMUM ACCEPTABLE WIRE SIZE. THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE WIRE FOR 20 AMP CIRCUITS (120 VOLT). LENGTHS (IN FEET) ARE INTENDED TO BE MAXIMUM. 6-10 AMPS 1-5 AMPS 120 VOLT 11-15 AMPS 325 FT. 110 FT. 160 FT. #12 200 FT. 70 FT. 100 FT. 490 FT. 165 FT. 245 FT. #10 #8 #6 12 Modular Furniture Outlets 0.00 0.00% 0.00 11 Miscellaneous - Continuous 0.00 0.00% 0.00 10 Exterior Lighting 0.00 0.00% 0.00 9 Computer Outlets 1.20 100.00% 1.20 7 Cooling 0.00 0.00% 0.00 6 Heating 0.00 0.00% 0.00 5 Kitchen (Commercial) 0.00 0.00% 0.00 4 Motors 0.00 0.00% 0.00 Total Est. Demand:25 A 3 Special Loads 0.00 0.00% 0.00 Total Conn.:25 A 2 Receptacles 4.86 100.00% 4.86 Total Est. Demand:6.06 1 Lighting - Continuous 0.00 0.00% 0.00 Total Conn. Load:6.06 0 Lighting - Non-Continuous 0.00 0.00% 0.00 Load Codes Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Demand Loads May Vary From Connected Loads Because of Demand Factors Total Amps:19 A 32 A Amps Circuit Numbering By Pole Position Circuit Total Connect Load:2.22 3.84 kVA 15 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 16 13 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 14 11 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 12 9 -- FILLER SPACE -- -- 1 -- -- 1 -- -- FILLER SPACE -- 10 7 2 REC. DATA COMMUNICATIONS 20 A 1 0.36 0.96 1 20 A T101 SAFE REC 2 8 5 2 REC. SECONDARY COMMUNICATION 20 A 1 0.36 0.36 1 20 A RECS. LOTTO EQ 44 2 6 3 2 SELF CHECK POS SYSTEM 20 A 1 1.32 1.20 1 20 A REC. BACK OFFICE COMPUTER 9 4 1 2 SELF CHECK POS SYSTEM 20 A 1 1.32 0.18 1 20 A REC. CCTV SERVICE 2 2 CCT No. Load Code Load Description Notes Brkr Size Poles A B Poles Brkr Size Notes Load Description Load Code CCT No. Furnished by Owner, installed by EC. Feed Thru Lugs:No Terminations:75°C CU Sections:1 Nema Rating:1 Feed Type:Bottom Skirt Type:None Status: New Trim:Door-In-Door Branch Breaker Type:Bolt-on IG Ground Busbar:No Mounting:Cabinet Fully / Series:Series Neutral Busbar:100% U System:1Ø, 3W A.I.C. Rating:35,000 A Ground Busbar:Yes Voltage:120/240 V Mains Type:M.C.B.Busbar Material:CUPANELBOARD Bus Rating:100 A Main Rating Upstream:40A Location:DIST. DP 1. CIRCUIT BREAKERS IN PANELBOARDS SHALL BE U.L. LISTED SERIES RATED WITH SPECIFIED 65K AIC UPSTREAM CIRCUIT BREAKER AND DOWNSTREAM 10K AMP RATED BRANCH CIRCUIT BREAKERS. 2. PROVIDE A PERMANENT LABEL READING "CAUTION - SERIES RATED SYSTEM 65K, "X" AMPS AVAILABLE." IDENTIFIED (LABELED) REPLACEMENT COMPONENTS REQUIRED. (REFER TO SHORT CIRCUIT CALCULATIONS FOR ACTUAL AMPS TO BE LABELED). 3. CIRCUIT BREAKERS SHALL BE A BOLT-ON TYPE, U.L. LISTED SERIES-RATED COMBINATION FROM PUBLISHED COMBINATION LISTINGS. GENERAL PANELBOARD NOTES OTP 11/12/24 JOB NO.: 33080 SUITE 5268 479-636-5004 ROGERS, AR 72756 DESIGNED BY: LHO 1805 N 2ND ST