Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Circle K - Yelm (Yelm & Killion), WA - Electrical Report
Administered by: ©2024 NEEA, All rights reserved Date: Nov 05, 2024 LIGHTING COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC For Building Department Use: Project Address 9548 Killion Rd SE Yelm, WA 98597 Applicant Name Sean Stanton Applicant Phone 479-636-5004 Applicant Email EnergyBG@teamofchoice.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Retail, Convenience Store Building Cond. Floor Area 5,192 General Project Types New Building New Building or Addition Lighting Scope Interior Lighting Exterior Lighting Alteration Lighting Scope Project Cond. Floor Area 5,192 Floors Above Grade 1 Compliance Method General Prescriptive Lighting Project Description Lighting Compliance Scope and Method Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification New Building Interior Lighting Space by space No Calculation Adjustments selected COMPLIES New Building Exterior Lighting Not applicable to exterior COMPLIES Additional Energy Efficiency (AEC) Measures Included No lighting or electrical additional energy efficiency measures included in project Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC Date Nov 05, 2024 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF)LPA (Watts/SF)Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD)Compliance Status Corridors General 130 0.41 53 Restroom General 538 0.63 339 Storage room General 498 0.38 189 Storage room General 373 0.38 142 Storage room 50-100 sf 88 0.38 33 Storage room 50-100 sf 72 0.38 27 Retail General sales 2,921 1.05 3,067 Retail General sales 224 1.05 235 Proposed Total LPD 4,073 Totals 4,086 4,073 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer A 43 41 1,763 11/5/24, 4:40 PM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfZXh0ZXJpb3IlN0NwZF9uZXdfYnVpbGRpbmcmdGZ2PWx0Z19zY29wZV9u… https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfZXh0ZXJpb3IlN0NwZF9uZXdfYnVpbGRpbmcmdGZ2PWx0Z19zY29wZV9uZXdfZXh0Z…1/3 Troffer AE 11 41 451 Troffer C 10 33 330 Troffer CE 2 33 66 Recessed downlight B 25 21 525 Suspended J 5 92 460 Suspended JE 1 92 92 Suspended K 4 44 176 Other fixture type D 4 30 120 Other fixture type DE 3 30 90 Proposed Total LPD 4,073 Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC Date Nov 05, 2024 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing-to-Remain Individual Fixtures Troffer A E0.0 LED New Fixture Description: 2'x4' H.E. Troffer Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Troffer AE E0.0 LED New Fixture Description: 2'x4' H.E. Troffer with Battery Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Troffer C E0.0 LED New Fixture Description: 2'x2' H.E. Troffer Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Troffer CE E0.0 LED New Fixture Description: 2'x2' H.E. Troffer with Battery Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Recessed downlight B E0.0 LED New Fixture Description: 6" Recessed Downlight Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Suspended J E0.0 LED New Fixture Description: 8' LED Linear Fixture Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Suspended JE E0.0 LED New Fixture Description: 8' LED Linear Fixture with Battery Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended K E0.0 LED New Fixture Description: 4' LED Linear Fixture Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Do these fixtures require specific application lighting controls?: None required Other fixture type D E0.0 LED New Fixture Description: 4' Gasketed Wrap Around Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type DE E0.0 LED New Fixture Description: 4' Gasketed Wrap Around With Battery Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC Date Nov 05, 2024 Lighting Power Calculation NEW BUILDING - EXTERIOR LIGHTING Compliance Verification COMPLIES Exterior Lighting Zone ZONE 2 Base Site Allowance 280 11/5/24, 4:40 PM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfZXh0ZXJpb3IlN0NwZF9uZXdfYnVpbGRpbmcmdGZ2PWx0Z19zY29wZV9u… https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfZXh0ZXJpb3IlN0NwZF9uZXdfYnVpbGRpbmcmdGZ2PWx0Z19zY29wZV9uZXdfZXh0Z…2/3 Exterior Lighting Power Allowance Exterior Surface Surface Sub-Type Surface Area (SF) LPA (Watts/SF) Linear Feet (LF) LPA (Watts/LF) Total Watts Allowed (LPA x SF) or (LPA x LF) Total Proposed Watts Compliance Status Building grounds Landscaping 32,660 0.025 817 Building grounds Outdoor dining area 858 0.273 234 Building grounds Walkways < 10 feet wide 6,228 0.07 436 Building grounds Walkways 10 feet and wider 1,588 0.07 111 Building entrances and exits Entry canopies 205 0.126 26 Outdoor sales Sales canopies - free standing 4,608 0.35 1,613 Uncovered parking areas and drives 43,242 0.026 1,124 Base Site Allowance 280 Totals 4,641 4,622 COMPLIES Proposed Exterior Lighting Power Density Fixture Type Fixture ID Exterior Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Canopy CAN1 Outdoor sales - Sales canopies - free standing 14 91 1,274 Canopy CAN2 Outdoor sales - Sales canopies - free standing 14 89 1,246 Ground recessed lighting L Building entrances and exits - Entry canopies 11 25 275 Pole-mounted A3B, A4B Uncovered parking areas and drives - 11 114 1,254 Pole-mounted A4B Building grounds - Outdoor dining area 1 114 114 Wall-mounted WP Building grounds - Walkways 10 feet and wider 3 51 153 Wall-mounted WP Building grounds - Walkways < 10 feet wide 2 51 102 Wall-mounted WP Building grounds - Landscaping 4 51 204 Proposed Total LPD 4,622 11/5/24, 4:40 PM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfZXh0ZXJpb3IlN0NwZF9uZXdfYnVpbGRpbmcmdGZ2PWx0Z19zY29wZV9u… https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PWx0Z19zY29wZV9uZXdfZXh0ZXJpb3IlN0NwZF9uZXdfYnVpbGRpbmcmdGZ2PWx0Z19zY29wZV9uZXdfZXh0Z…3/3