Loading...
Circle K - Yelm (Yelm & Killion), WA - Envelope ReportAdministered by: ©2024 NEEA, All rights reserved Date: Nov 11, 2024 ENVELOPE COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC For Building Department Use: Project Address 9548 Killion Rd SE Yelm, WA 98597 Applicant Name Sean Stanton Applicant Phone 479-636-5004 Applicant Email EnergyBG@teamofchoice.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type(s)Retail, Convenience Store Building Cond. Floor Area 5,192 Project Scope New Building Space Conditioning Categories Fully Conditioned Walk-in Cooler Walk-in Freezer Project Cond. Floor Area 5,192 Floors Above Grade 1 Compliance Method General Prescriptive Envelope Project Description Envelope Compliance Scope and Method Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification New Building Walk-in Freezer Prescriptive NA No Calculation Adjustments allowed NA COMPLIES New Building Walk-in Cooler Prescriptive NA No Calculation Adjustments allowed NA COMPLIES New Building Fully Conditioned Prescriptive 8.33% / 0%None selected No alternates selected COMPLIES Additional Energy Efficiency (AEC) Measures Included No envelope or miscellaneous additional energy efficiency measures included in project Load Management (LDM) Measures Included No envelope or miscellaneous load management measures included in project Air Barrier Testing Air barrier testing not included Air Barrier Comments SIP Panels Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC Date Nov 11, 2024 Scope & Space Conditioning NEW BUILDING - WALK-IN FREEZER Compliance Verification COMPLIES Window-to-wall Ratio NA Skylight-to-roof-ratio NA Vertical Fenestration Alternate NA Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Walk-in freezer ceiling A1.6 Walk-In Freezer Ceiling Interior partition R-33 (< 0.04%)72 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Walk-in freezer wall A1.2 Hallway Wall Interior partition R-33 (< 0.04%)53 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in freezer wall A1.2 Side Wall Interior partition R-33 (< 0.04%)80 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in freezer wall A1.2 Storage Room Wall Interior partition R-33 (< 0.04%)80 Envelope assembly type:U-Factor Source: U-Factor Source Description: 11/11/24, 4:21 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 1/4 Walk-in freezer wall A1.2 Back Wall Interior partition R-33 (< 0.04%)53 Envelope assembly type:U-Factor Source: U-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Walk-in freezer door A6.0 D2 Interior partition R-32 24 U-Factor Source:U-Factor Source Description: Does opaque freezer door have glazing?: No Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC Date Nov 11, 2024 Scope & Space Conditioning NEW BUILDING - WALK-IN COOLER Compliance Verification COMPLIES Window-to-wall Ratio NA Skylight-to-roof-ratio NA Vertical Fenestration Alternate NA Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Walk-in cooler ceiling A1.2 Walk-in Cooler Ceiling Interior partition R-29 (< 0.04%)373 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler ceiling A4.0 Cold Vault Ceiling Interior partition R-29 (< 0.04%)224 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Walk-in cooler wall A1.2 Cooler (Back)Interior partition R-29 (< 0.04%)354 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cooler (Reach-In)Interior partition R-29 (< 0.04%)354 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cooler/Cold Vault (Cooler Side)Interior partition R-29 (< 0.04%)67 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cooler (Back Room)Interior partition R-29 (< 0.04%)67 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A2.1 Cold Vault (Back)Interior partition R-29 (< 0.04%)219 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cold Vault (Storage Room)Interior partition R-29 (< 0.04%)89 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cold Vault (Long Cavity)Interior partition R-29 (< 0.04%)44 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cold Vault (Short Cavity)Interior partition R-29 (< 0.04%)21 Envelope assembly type:U-Factor Source: U-Factor Source Description: 11/11/24, 4:21 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 2/4 Walk-in cooler wall A1.2 Cold Vault (Reach-In)Interior partition R-29 (< 0.04%)116 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cold Vault (Entrance)Interior partition R-29 (< 0.04%)59 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cold Vault (Lip)Interior partition R-29 (< 0.04%)5 Envelope assembly type:U-Factor Source: U-Factor Source Description: Walk-in cooler wall A1.2 Cooler/Cold Vault (Cold Vault Side)Interior partition R-29 (< 0.04%)84 Envelope assembly type:U-Factor Source: U-Factor Source Description: Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Walk-in cooler slab-on-grade floor N/A N/A Applying slab-on-grade floor exception?: No Walk-in cooler slab-on-grade floor N/A Cooler Floor Applying slab-on-grade floor exception?: No Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Walk-in cooler door A6.0 D2 Interior partition R-25 24 U-Factor Source:U-Factor Source Description: Does opaque cooler door have glazing?: No Walk-in cooler door A6.0 D2 Interior partition R-25 24 U-Factor Source:U-Factor Source Description: Does opaque cooler door have glazing?: No Walk-in cooler door A6.0 D2 Interior partition R-25 24 U-Factor Source:U-Factor Source Description: Does opaque cooler door have glazing?: No Glazed Doors Location in Documents Assembly ID Assembly Location Shading (PF)Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Transparent reach-in cooler doors A3.1 R007 Interior partition Reach-in cooler door glazing type: Double-pane filled with inert gas Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC Date Nov 11, 2024 Scope & Space Conditioning NEW BUILDING - FULLY CONDITIONED Compliance Verification COMPLIES Window-to-wall Ratio 8.33%Skylight-to-roof-ratio 0%Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Wood-framed and other - Commercial A5.2 Front Wall Exterior R-0 R-25.4 (< 0.04%)U-0.039 1,876 Which code target does wall comply with?: Wall Assembly U-factor U-Factor Source: U-Factor Source Description:Wall Framing Type: Standard Framing Depth:Other Framing Depth: Framing Spacing (OC): Wood-framed and other - Commercial A4.0 Side Entrance Wall Exterior R-0 R-25.4 (< 0.04%)U-0.039 742 Which code target does wall comply with?: Wall Assembly U-factor U-Factor Source: 11/11/24, 4:21 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 3/4 U-Factor Source Description:Wall Framing Type: Standard Framing Depth:Other Framing Depth: Framing Spacing (OC): Wood-framed and other - Commercial A5.1 Back Room Wall Exterior R-0 R-25.4 (< 0.04%)U-0.039 742 Which code target does wall comply with?: Wall Assembly U-factor U-Factor Source: U-Factor Source Description:Wall Framing Type: Standard Framing Depth:Other Framing Depth: Framing Spacing (OC): Wood-framed and other - Commercial A4.0 Rear Wall Exterior R-0 R-25.4 (< 0.04%)U-0.039 1,770 Which code target does wall comply with?: Wall Assembly U-factor U-Factor Source: U-Factor Source Description:Wall Framing Type: Standard Framing Depth:Other Framing Depth: Framing Spacing (OC): Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab A4.0 Floor At grade level R-10 318 Slab Insulation Method: Uninsulated slab F-Factor Source: F-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Swinging A6.0 111 Exterior U-0.37 43 What percentage of this opaque door is glazing?: 50% or less U-Factor Source: U-Factor Source Description:Is this a public entrance door?: Yes Door enclosed within a vestibule?: Yes Swinging A6.0 D2 Exterior U-0.37 24 What percentage of this opaque door is glazing?: 50% or less U-Factor Source: U-Factor Source Description:Is this a public entrance door?: No Vertical Fenestration Location in Documents Assembly ID Assembly Location Shading (PF)Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Fixed - Class AW or site built A6.0 A Exterior PF ≥ 0.5 SHGC-0.25 U-0.27 123 U-Factor & SHGC Source:U-Factor Source Description: Fixed - Class AW or site built A6.0 B Exterior PF ≥ 0.5 SHGC-0.25 U-0.27 256 U-Factor & SHGC Source:U-Factor Source Description: Fixed - Class AW or site built A6.0 C, C1 Exterior PF ≥ 0.5 SHGC-0.25 U-0.27 93 U-Factor & SHGC Source:U-Factor Source Description: 11/11/24, 4:21 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk4OTkmZnZpPTI3JnJlc2V0PTEmY3RpPTkx&debug=1 4/4