Circle K - Yelm (Yelm & Killion), WA - Mechanical OTPA A B B 22 11 8"Ø C 200 TYP 2 12"Ø A 450 TYP 2 10"Ø A 400 W/DAMPER IN VERTICAL 12"x12"B 350 FF 2 FF 3 FF 1 WALK-IN FREEZER WALK-IN COOLER CASHIER MEN'S RESTROOM WOMEN'S RESTROOM STORAGE ROOM BACK ROOM SALES FLOOR 2 COLD VAULT SALES FLOOR 1 HALLWAY 1 2 2 2 CO CO 4 5 5 6 7 RTU1 8 12"Ø A 450 W/DAMPER IN VERTICAL CO2 18"Ø 10 " Ø 1" CD 3/4" CD 12"Ø 8" Ø 8" Ø 10"Ø 12"Ø A 450 TYP 2 S DS 20 " x 2 2 " 14"Ø 9 11 113/4" CD 3/4" CD SALES FLOOR 3 RESTROOM ENTRY 12 " Ø 18 " x 2 4 " 18"Ø 12"Ø A 450 18"Ø 333 3 3/4" CD CO 3 3/4" CD CO B501 B502 14 " Ø 12"Ø PREP AREA 2 12"x12"E 225 TYP 2 12 14"Ø 13 S14 10"Ø 10"Ø A 400 14"Ø CO CO 12"Ø RTU1 14"Ø OAU1 900 18 " x 1 0 " 10"Ø A 400 12"Ø A 425 10"Ø 12"Ø 8"Ø A 75 12 " Ø 18"Ø 14"Ø 14"Ø 18"Ø 2 . . 2 2 14 0 15 12 " Ø 8"Ø A 100 2 12"Ø 15 10"Ø 8" Ø 10 12"x12"F 1 TYP 5 - REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.1 PROJECT NUMBER: 24212 MECHANICAL - FLOOR PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS 3/16" = 1'-0" 1 MECHANICAL FLOOR PLAN A. EQUIPMENT SHALL COMPLY WITH ASHRAE STANDARDS. B. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, ACTS, AND AUTHORITIES HAVING JURISDICTION. C. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE INDUSTRY STANDARD OF GOOD PRACTICE AND SAFETY, AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. D. ALL WORK SHALL BE LOCATED TO PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN AND PROPER OPERATION AND SERVICE OF EQUIPMENT. E. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES. CLOSELY COORDINATE ALL WORK WITH ALL OTHER TRADES. FAILURE OF THE CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES SHALL RELIEVE THE OWNER/ENGINEER FROM ANY ADDED COSTS. KEYNOTES 1 PROGRAMMABLE THERMOSTAT WITH REMOTE TEMPERATURE SENSORS. REF ENERGY MANAGEMENT SYSTEM DRAWING. 2 ROUTE ALL DUCTWORK WITHIN THE JOISTS UNLESS OTHERWISE SPECIFIED. 3 PROVIDE COPPER DRAIN LINES FROM COOLER/FREEZER EVAPORATORS. VERIFY LOCATIONS WITH REFRIGERATION PLANS (EVAPORATORS PROVIDED BY CK/OTHERS). DRAIN LINES IN FREEZER SHALL BE INSULATED AND HEAT TRACED. HEAT TRACE SHALL BE SELF REGULATING 120V, 5 W/FT RAY-CHEM XL-TRACE OR EQUIVALENT. REFER TO ELECTRICAL SHEETS FOR POWER SUPPLY. 4 COPPER CONDENSATE DRAIN FROM COOLERS AND FREEZER EVAPORATORS THRU WALL 12" AFF. ROUTE TO GRASSY AREA. PROVIDE TRAP AT TERMINATION. HEAT TRACE PIPING EXPOSED TO FREEZING. 5 MECHANICAL CONTRACTOR SHALL INSTALL A 6" DIAMETER PVC PIPE, SCHEDULE 40, FROM TOP OF SLAB, DOWN BELOW SLAB, OVER TO DELI CASE AND TERMINATE AT SLAB WITH PULL STRING AS SHOWN. THE REFRIGERANT PIPING WILL BE INSTALLED IN THIS PIPE SLEEVE. CONTRACTOR SHALL PROVIDE LONG RADIUS TYPE SWEEP ELBOWS AS REQUIRED. MECHANICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR THE TIMING OF THIS INSTALLATION. PIPING SHALL BE CAPPED AT OPEN ENDS AS SOON AS IT IS INSTALLED TO PREVENT DIRT, DEBRIS, AND WATER FROM COLLECTING INSIDE OF PIPE. COORDINATE TERMINATION POINT AT SLAB WITH DELI CASE INSTALLATION INSTRUCTIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ELEVATION OF PIPE BELOW SLAB WITH PLUMBING UTILITIES. 6 CO2 LOUVRED CABINET. SEE SHEET M1.4 FOR DETAIL. 7 ALL AIR GAPS TO BE MINIMUM TWICE THE DIAMETER OF THE INDIRECT WASTE PIPE AS PER IPC 802.3.1. 8 SMOKE DETECTOR FOR UNIT SHUT-DOWN TO BE FACTORY INSTALLED BY MANUFACTURER. 9 PROVIDE CO2 DETECTOR AND ALARM. SEE SHEET M1.5 FOR DETAIL OF CO2 DETECTOR AND ALARM SYSTEM. 10 EXTERIOR ROOF ACCESS. 11 MECHANICAL CONTRACTOR TO PROVIDE COPPER DRAIN LINES FROM ROOFTOP EQUIPMENT. 12 PROVIDE RUNNING TRAP IN COOLER. 13 COPPER DRAIN LINE FROM COOLER AND FREEZER EVAPORATORS DOWN IN WALL. TERMINATE AT FLOOR SINK WITH MINIMUM 2" AIR GAP. 14 REMOTE TEMPERATURE SENSOR IN SUPPLY AND RETURN AIR DUCT. 15 FULL SIZE SUPPLY & RETURN AIR DUCTS DOWN THRU ROOF FROM ROOFTOP PACKAGE UNIT. GENERAL NOTES OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST A A B B 22 11 1 1 1 1 1 1 1 2 2 3 4 5 6 3 3 7 1 8 9 3 9 OAU1 RTU1 10 7 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.1.1 PROJECT NUMBER: 24212 MECHANICAL - ROOF PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA MKE JMS SAG JMS 3/16" = 1'-0" 1 MECHANICAL ROOF PLAN A. EQUIPMENT SHALL COMPLY WITH ASHRAE STANDARDS. B. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, ACTS, AND AUTHORITIES HAVING JURISDICTION. C. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE INDUSTRY STANDARD OF GOOD PRACTICE AND SAFETY, AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. D. ALL WORK SHALL BE LOCATED TO PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN AND PROPER OPERATION AND SERVICE OF EQUIPMENT. E. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES. CLOSELY COORDINATE ALL WORK WITH ALL OTHER TRADES. FAILURE OF THE CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES SHALL RELIEVE THE OWNER/ENGINEER FROM ANY ADDED COSTS. GENERAL NOTES KEYNOTES 1 CONDENSING UNIT FOR REFRIGERATION EQUIPMENT BY VENDOR SHOWN FOR REFERENCE ONLY. 2 VTR'S SHOWN FOR REFERENCE ONLY, REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. PROVIDE MINIMUM 10'-0" SEPARATION FROM OUTSIDE AIR INTAKES ON HVAC UNITS. 3 PIPE PORTAL FOR REFRIGERANT PIPING, ELECTRICAL CONDUIT AND/OR CONDENSATE LINE AS REQUIRED, REFER TO REFRIGERANT LINE GOOSENECK DETAIL. 4 3" GREASE TRAP VENT DOWN IN WALL AND CONNECT TO GREASE TRAP. 5 SATELLITE DISH SHOWN FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR INFO. 6 FREEZE LESS ROOF HYDRANT. REFERENCE PLUMBING SHEETS. 7 MECHANICAL CONTRACTOR TO PROVIDE COPPER DRAIN LINES FROM ROOFTOP EQUIPMENT. 8 EXTERIOR ROOF ACCESS SHOWN FOR REFERENCE ONLY, REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. 9 RUSKIN SD60 30'x20' SMOKE DAMPER INSTALLED IN DRAFT STOP. DAMPER SHALL INCLUDE 24V NO FLOW DUCT SMOKE DETECTOR AND 24V FAST ACTING ACTUATOR. GC TO FIELD VERIFY EXACT LOCATION. 10 ROOFTOP HVAC UNIT INSTALLED ON FACTORY CURB ON ROOF. OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST MANUFACTURERS LABEL PER 2021 WSMC SECTION 301.9 IDENTIFICATION LABEL PER 2021 WSMC SECTION 301.9 OUTSIDE AIR INTAKE HOOD LABEL TO BE ENGRAVED UV STABLE PLASTIC SCREWED TO UNIT FILTER ACCESS PANEL FLEX CONNECTION ON SUPPLY & RETURN ACOUSTICALLY LINED SUPPLY AND RETURN AIR DUCTS, SAME SIZE AS UNIT CONNECTION REFER TO SPECS FOR INSULATION REQUIREMENTS CONDENSATE DRAIN, SEE PLAN FOR SIZING AND ROUTING CLEAN OUT 4" THICK, 6 PCF DENSITY INSULATION INSIDE CURB AROUND DUCT DROPS. INSULATION INSTALLED FULLY INSIDE CURB PERIMETER. 14" HIGH FACTORY SUPPLIED CURB SECURELY ANCHORED TO ROOF, FLASH AND COUNTER-FLASH WATERTIGHT (SET UNIT LEVEL). SECURE UNIT TO CURB; REF RTU ANCHOR BRACKET DETAIL. SECURE UNIT TO ROOF CURB, CAULK WATERTIGHT. PROVIDE ADEQUATE CLEARANCE AROUND PIPING TO REMOVE ACCESS PANEL ON UNIT. ROOFTOP UNIT DUCT HVAC UNIT POWER SOURCE NOTES: TO FIRE DETECTION OR ALARM SYSTEM (IF PRESENT) "LOW FLOW" TYPE DUCT SMOKE DETECTOR MOUNTED ON THE RETURN AIR DUCT WHERE SHOWN. FURNISHED, INSTALLED, AND CONTROL WIRING BY MECHANICAL CONTRACTOR UNLESS FACTORY INSTALLED IN RTU. POWER WIRING BY ELECTRICAL/FIRE ALARM CONTRACTOR. SEE PLANS FOR ALL LOCATIONS. PROVIDE REMOTE VISIBLE AND AN AUDIBLE SIGNAL ALONG WITH LED BELOW CEILING AS REQUIRED PER 2021 WS MECH CODE AND NFPA. MECHANICAL CONTRACTOR SHALL FURNISH, INSTALL, AND PROVIDE WIRING TO HVAC UNIT TO SHUT DOWN UNIT UPON DETECTION OF SMOKE UNLESS FACTORY INSTALLED IN RTU. MECHANICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY RELAYS, CONTRACTORS, POWER MODULES, ETC. AS NECESSARY TO PROVIDE A COMPLETE OPERATIONAL SYSTEM. COORDINATE WITH ELECTRICAL/FIRE ALARM CONTRACTOR TO VERIFY VOLTAGE REQUIREMENTS, LOCATIONS, ETC. ELECTRICAL/FIRE ALARM CONTRACTOR SHALL PROVIDE WIRING IF FIRE DETECTION OR ALARM SYSTEMS ARE PROVIDED FOR THE BUILDING, THE SMOKE DETECTORS SHALL BE SUPERVISED BY SUCH SYSTEMS. SMOKE DETECTORS REQUIRED BY 2021 WSMC SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. DUCT SMOKE DETECTORS REQUIRE A REMOTE LED INDICATOR THRU THE CEILING LEVEL. NFPA 72 3-8.3. DUCT SMOKE DETECTORS SHALL ACTIVATE A VISIBLE AND AUDIBLE SIGNAL AT A NORMALLY OCCUPIED LOCATION AND SHALL BE MONITORED BY THE FACP AND REPORT AS A SUPERVISORY SIGNAL PER NFPA 72 AND THE 2021 WS MECH CODE . DUCT SMOKE DETECTORS TO PROVIDE SHUTDOWN IN 30 SECONDS OR LESS. 3 3 4 1 2 1 2 4 DS INTERNAL DRAIN PAN IN UNIT CLEAN OUT COIL 3" 3" OPEN 6" CONDENSATE DRAIN LINE, SEE PLAN FOR SIZE NOTES: ~ 1. CONDENSATE DRAIN LINES SHALL BE GRADED CONTINUOUSLY AND UNIFORMLY TO POINT OF DISCHARGE. MINIMUM OF 1/8" PER FOOT. 2. CONDENSATE DRAIN LINES SHALL BE TYPE "M" HARD DRAWN COPPER TUBING ASTM B-88. 3. GENERAL CONTRACTOR TO SUPPLY AND INSTALL ALL CONDENSATE DRAINS PER MANUFACTURER'S RECOMMENDATIONS. 4. INSULATE PRIMARY COIL CONDENSATE INSIDE BUILDING IN ACCORDANCE WITH SHEET SPECIFICATIONS CENTERLINE CE N T E R L I N E CENTERLINE RADIUS = 1.5W W R NOTE: RADIUS ELBOWS WITH MITERED THROAT ARE NOT ALLOWED RADIUS ELBOWMITERED ELBOW WITH TURNING VANES STRAP SHEET METAL SCREWS NOTE: USE EITHER ANGLE OR STRAP ANGLERODS REFER TO SMACNA HVAC DUCT CONSTRUCTION STANDARDS TABLE 4-1 FOR "RECTANGULAR DUCT HANGERS MINIMUM SIZE". SHEET METAL SCREW OR POP RIVETS ROD STRAP STRAP 1 1 / 2 " STRAP 1/4" BOLT REFER TO SMACNA HVAC DUCT CONSTRUCTION STANDARDS TABLE 4-2 FOR "MINIMUM HANGER SIZES FOR ROUND DUCT". NOTE: AIR FLOW AI R F L O W BRANCH DUCT MAIN DUCT 1. FABRICATE PER SMACNA DUCT CONSTRUCTION STANDARDS FIGURE #2-8. 2. DO NOT USE EXTRACTORS IN BRANCH DUCTWORK. 3 0 ° W W/ 4 ( M I N . 4 " ) 30° 3 0 ° 45° AIR FLOW AIR FLOW BRACKET ATTACHMENT HVAC UNIT BRACKET #12 TEK SCREWS (TYP SIX PER BRACKET)CURB ROOF ∅3/16 SCREW HOLES TWO PER ROW EQ SPACED TYP BRACKETS ARE FURNISHED WITH RTU. BRACKET CONSTRUCTION, QUANTITIES, AND SPACING SHOWN ON THIS DETAIL IS FOR GENERAL COORDINATION ONLY. INSTALL BRACKETS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. COORDINATE FINAL BRACKET LOCATIONS WITH EQUIPMENT. DO NOT OBSTRUCT OPENINGS OR UTILITY CONNECTIONS. RTU BRACKET 16 GA GALV TYP BRACKET TYP RTU BRACKET LAYOUT ∅3/16 SCREW HOLES FOUR PER ROW EQ SPACED TYP BRANCH DUCT LAY-IN CEILING TYPICAL CEILING DIFFUSER OR RETURN GRILLE SPIN-IN OR FLANGED FITTING WITH LOCKING QUADRANT AND 2" STANDOFF. 13"DIA AND LARGER TO HAVE SOLID ROD, NYLON BUSHINGS LOCKING QUADRANT AND 2" STANDOFF, REFERENCE SMACNA DETAIL 7-4, 2005 EDITION 1", 26 GA. SUPPORT FROM STRUCTURE @ MAX. 4'-0" O.C. TAPE AROUND SNUGGLY Z WRAPS PRIOR TO INSTALLING LINE STRAP RIGID DUCT WHERE BRANCH DUCT EXTENDS 4'-0" AND LONGER THERMAFLEX TYPE M-KE FLEX DUCT WITH CPE LINER & R=6.0 INSULATION, CLASS 1 FLEXIBLE DUCT. DIAMETER EQUAL TO DIFFUSER NECK SIZE (MAX LENGTH 4'-0") 1" WIDE X 20 GA. STRAP W/ TIGHTENING SCREW -SECURE STRAP W/ SHEET METAL SCREWS 3" O.C. MAXIMUM (TYPICAL) PROVIDE MIAMI TECH #LJ10 OR EQUAL 4" OPENING 7" CLEARANCE SEAL OPENING WATERTIGHT PROVIDE AIR-TIGHT FOAM SEAL AROUND PIPING AND CONDUITS PROVIDE INSULATION AT ROOF INTERFACE AROUND PIPING EQUIVALENT TO ROOF INSULATION AMOUNT PROVIDE SHEET METAL ENCLOSURE PANEL WITH OPENINGS FOR PIPING AND CONDUIT REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.2 PROJECT NUMBER: 24212 MECHANICAL - DETAILS (1 OF 3) CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS N.T.S. 1 ROOF-TOP PACKAGE UNIT DETAIL N.T.S. 5 DUCT SMOKE DETECTOR CONNECTION DETAIL N.T.S. 10 CONDENSATE DRAIN TRAP DETAIL N.T.S. 7 DUCT ELBOW DETAILS N.T.S. 9 RECTANGULAR DUCT HANGER DETAIL N.T.S. 4 ROUND DUCT HANGER DETAIL N.T.S. 6 DUCT CONNECTION N.T.S. 2 RTU ANCHOR BRACKET DETAIL OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST N.T.S. 8 DIFFUSER/GRILLE CONNECTION DETAIL N.T.S. 3 REFRIGERANT LINE GOOSENECK DETAIL REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.2.1 PROJECT NUMBER: 24212 MECHANICAL - DETAILS (2 OF 3) CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS OTP 11/12/24 FOR INOFRMATION ONLY REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.2.2 PROJECT NUMBER: 24212 MECHANICAL - DETAILS (3 OF 3) CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS OTP 11/12/24 FOR INOFRMATION ONLY 1. SIZE ALL UNITS ON SUMMER AMBIENT TEMPERATURE: 95° F. 2. VERIFY VOLTAGE/PHASE WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 3. COOLING CAPACITY, MINIMUM HEAT CAPACITY AND CFM ARE MINIMUM OUTPUT REQUIRED. ALL UNITS SHALL HAVE NO LESS THAN 98% OF THESE CAPACITIES. COOLING CAPACITY IS GROSS COIL CAPACITY REQUIRED (FAN HEAT NOT DEDUCTED). 4. UNITS TO BE FURNISHED WITH FACTORY INSTALLED RETURN AIR SMOKE DETECTORS. 5. PROVIDE 14" ROOF MOUNTING CURB. VERIFY INSULATION HEIGHT. PROVIDE SEISMIC/WIND RESTRAINT BRACKETS. 6. PROGRAMMABLE THERMOSTAT WITH REMOTE SENSORS BY EMS SUPPLIER. 7. PROVIDE FACTORY INSTALLED ECONOMIZER WITH ENTHALPY SENSOR AND CONTROL ACCESSORIES. 8. PROVIDE WITH AUXILIARY HEATER. 9. PROVIDE WITH HAIL GUARDS 10. PROVIDE FACTORY INSTALLED DISCONNECT. 11. PROVIDE WITH UNPOWERED GFCI CONVENIENCE OUTLET. 12. PROVIDE COIL COATING. 13. PROVIDE CONDENSATE OVERFLOW SHUTDOWN SWITCH. NOTES: 1. FIELD PAINT ALL DIFFUSERS AND GRILLES - COLOR WHITE 2. SA=SUPPLY AIR 3. EA=EXHAUST AIR 4. RA=RETURN AIR 5. TA=TRANSFER AIR 6. PROVIDE VOLUME / BALANCE DAMPERS WHERE INDICATED ON DRAWINGS. a. ROUND (MANUFACTURER / MODEL): RUSKIN / MDRS25, DAYTON / 2TF (OR EQUIVALENT) b. RECTANGULAR (MANUFACTURER / MODEL): RUSKIN / MD25, DAYTON / 22CV (OR EQUIVALENT) 7. PROVIDE DIFFUSER TO DUCT CONNECTION TRANSITION AS REQUIRED. 8. PROVIDE MANUFACTURERS SECTORIZING BAFFLES WHERE INDICATED BY FLOW ARROWS ON PLAN. USE A 4- WAY THROW IF NO THROW ARROWS ARE SHOWN. NOTE: A. PROVIDE WALL MOUNTED CONTROL PANEL. B. PROVIDE HARD-WIRED ROLLER TYPE MICROSWITCH AT DOOR/WINDOW. NO OTHER ON/OFF SWITCH IS TO BE PROVIDE/INSTALLED. C. PROVIDE INLET LOUVER AND FILTER. D. PROVIDE WALL MOUNTING BRACKETS. NOTES: 1. CALCULATIONS WERE PERFORMED WITH TRANE TRACE 700 SOFTWARE PROGRAM IN COMPLIANCE WITH ASHRAE FUNDAMENTALS. 2. EQUIPMENT SIZING MEETS THE IECC 403.2.2 REQUIREMENTS 3. ALL MECHANICAL AIR CONDITIONING EQUIPMENT TO HAVE MINIMUM EFFICIENCY RATING PER 2021 WSEC, TABLE C403.2.3. SUBMIT MECHANICAL AC EQUIPMENT TO OWNER OR ENGINEER FOR REVIEW AND APPROVAL PRIOR TO ORDER. NOTES: REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.2.3 PROJECT NUMBER: 24212 MECHANICAL - SCHEDULES CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS AIR DEVICE SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL FRAME MATERIAL- MODULE A SA TITUS TMSA LAY-IN STEEL 24X24 B EA TITUS 23R LAY-IN STEEL 24X24 C SA TITUS TDC SURFACE MOUNT STEEL12X12 E EA TITUS 23R SURFACE MOUNT STEEL12X12 F RA TITUS 23R LAY-IN STEEL 24X24 AIR CURTAIN SCHEDULE MARK LOCATION MANUFACTURER MODEL FPM MOTOR SONES WEIGHT NOTESPOWER VOLTAGE PH HZ MCA FF 1 HALLWAY MARS AIR STD260-2U 3400 0.50 hp 115 V 1 60 Hz 12.75 A 68 90 lb A,B,C,D FF 2 SALES FLOOR 2 MARS AIR STD236-1U 1800 0.50 hp 115 V 1 60 Hz 6.40 A 66 60 lb A,B,C,D FF 3 SALES FLOOR 3 MARS AIR STD236-1U 1800 0.50 hp 115 V 1 60 Hz 6.40 A 66 60 lb A,B,C,D ROOFTOP UNIT SCHEDULE MARK MANUFACTURER MODEL SUPPLY FAN COOLING CAPACITY HEAT PUMP HEAT RATING OR NATURAL GAS HEAT OUTSIDE AIR CFM WEIGHT (LBS) ELECTRICAL DATA AUXILIARY ELEC HEAT CFM ESP (IN.)HP BTU/HR VOLTS PH HZ MCA MOCP KW RTU1 Carrier 50FCQ 4,000 10.0 ton 3 60 Hz OUTSIDE AIR CALCULATION OUTSIDE AIR REQUIREMENTS PER TABLE 403.3 AND 403.3.1.2, 2021 IMC NAME MINIMUM EXHAUST AREA # PEOPLE/ 1000 FT² NUMBER OF PEOPLE OUTDOOR AIR PER PERSON OUTDOOR AIR PER AREA PEOPLE LOAD REQUIRED (PLR) OSA BUILDING LOAD REQUIRED (BLR) OSA SYSTEM EFFICENCY VALUE TOTAL OSA REQUIRED [(PLR+BLR)/SYSTEM EFFICENCY] CASHIER 0 226 SF 15 3 7.5 CFM 0.12 CFM/SF 25 CFM 27 CFM 0.8 66 CFM HALLWAY 0 93 SF 15 1 7.5 CFM 0.12 CFM/SF 10 CFM 11 CFM 0.8 27 CFM MEN'S RESTROOM 200 222 SF 0 0.0 CFM 0.00 CFM/SF 0 CFM 0 CFM 0.8 0 CFM REAR ENTRY HALLWAY 0 49 SF 9 0 7.5 CFM 0.12 CFM/SF 3 CFM 6 CFM 0.8 12 CFM RESTROOM ENTRY 0 91 SF 0 0.0 CFM 0.00 CFM/SF 0 CFM 0 CFM 0.8 0 CFM SALES FLOOR 1 0 633 SF 7 5 7.5 CFM 0.06 CFM/SF 35 CFM 38 CFM 0.8 92 CFM SALES FLOOR 2 0 517 SF 7 4 7.5 CFM 0.06 CFM/SF 29 CFM 31 CFM 0.8 75 CFM STORAGE ROOM 0 87 SF 20 2 0.0 CFM 0.12 CFM/SF 0 CFM 10 CFM 0.8 13 CFM WOMEN'S RESTROOM 200 223 SF 0 0.0 CFM 0.00 CFM/SF 0 CFM 0 CFM 0.8 0 CFM BACK ROOM 0 494 SF 20 10 0.0 CFM 0.12 CFM/SF 0 CFM 59 CFM 0.8 74 CFM PREP AREA 0 224 SF 15 3 7.5 CFM 0.12 CFM/SF 25 CFM 27 CFM 0.8 65 CFM SALES FLOOR 3 0 1315 SF 7 10 7.5 CFM 0.06 CFM/SF 73 CFM 79 CFM 0.8 190 CFM TOTALS 4174 SF 39 202 CFM 289 CFM 613 CFM AIR BALANCE SCHEDULE MARK O.A. E.A. PRESSURE OAU1 900 CFM 0 CFM 900 CFM TOTAL EXHAUST: 1 900 CFM 900 CFM 2021 WSEC LOAD SUMMARY AREA COOLING LOAD CALCULATION (MBH) PROVIDED EQUIPMENT COOLING CAPACITY (MBH) SENSIBLE TOTAL SENSIBLE TOTAL RTU1 100.1 110.6 93.4 125.3 SALES OSA RATE USES SUPERMARKET OCCUPANCY CLASSIFICATION OTP 11/12/24 .75 2.4 115000 0 1293 208 133 150 24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST 800 CFM 100 CFM 100 CFM800 CFM T ~~ ~~ ~ ~ ~ ~ ~ ~ ~~ ~ ~ 2021 WSEC COMPLIANCE NOTES SECONDARY CONDENSATE DRAIN PIPING FLOWSTREAM ID PIPE FITTING SYMBOLS TEE CONNECTION CAPPED OUTLET FLEX CONNECTION TOP CONNECTION, 45° OR 90° BOTTOM CONNECTION, 45° OR 90° STRAINER, FLANGED ECCENTRIC REDUCER SWITCH, PRESSURE SWITCH, TEMPERATURE TEST & PRESSURE (T&P) FITTING PRESSURE GAUGE W/ COCK PRESSURE GAGE W/O COCK REDUCER OR INCREASER DIRECTION OF FLOW POINT OF NEW CONNECTION TO EXISTING NEW PIPE CONNECTION TO EXISTING PIPING SLOPE IN DIRECTION SHOWN (DOWN) EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN NEW PIPING DN F P T UNION ORIFICE UNION THERMOMETER FLANGED UNION STRAINER SWITCH, FLOW FLEX PIPE PIPE CAP RISE IN PIPE PIPE PLUG PIPE GUIDES DROP AT END DROP AT MID ANCHOR ANCHOR, WALL BLIND FLANGE ABBREVIATIONS CD SCD D CONDENSATE DRAIN DRAIN LINE GENERAL NOTES CODE INFORMATION ANNOTATION SYMBOLS HEX SYMBOL INDICATES NEW EQUIPMENT NUMBER REFERS TO SPECIFIC EQUIPMENT IDENTIFIED IN EQUIPMENT SCHEDULE DUCTWORK SYMBOLS XXX CFM MARK (AS SHOWN ON SCHEDULE) NECK SIZE (Ø DIA. OR H" x W" RECTANG.) NUMBER REFERS TO SPECIFIC EQUIPMENT SYMBOL INDICATES NEW EQUIPMENT OUTSIDE AIR CFM REQUIRED POINT OF NEW CONNECTION TO EXISTING NORTH ARROW FLOW ARROWS ROOM NUMBER KEYED NOTE DESCRIPTIONSYMBOL AIR TERMINAL SYMBOLS V12 X REVISION TRIANGLE REVISION NUMBER DETAIL NUMBER DETAIL SYMBOL DRAWING WHERE DETAIL APPEARS OVAL SYMBOL INDICATES A CONTROL VALVE V-NUMBER REFERS TO A SPECIFIC VALVE IDENTIFIED IN THE CONTROL VALVE SCHEDULE X XXX X SECTION CUT SYMBOL SECTION LETTER SECTION LETTER SECTION CUT SYMBOL DRAWING WHERE SECTION APPEARS ACCESS DOOR 1-1/2 X BRANCH DUCT FROM SIDE OF MAIN SQUARE ELBOW WITH TURNING VANES DUCT TRANSITION EXISTING DUCTWORK RADIUS TYPE 90° ELBOW ACCESS PANEL (AP) NEW EXISTING RELOCATED N E R NEW/RELOCATED SUPPLY DIFFUSER, NECK SIZE, ANDBALANCE AIR AS INDICATED (MATCH EXISTING) NEW/RELOCATED RETURN GRILLE WITH BOOT(MATCH EXISTING) EXISTING SUPPLY DIFFUSER EXISTING RETURN GRILLE WITH BOOT RELOCATED EXISTING GRILLE OR DIFFUSER RELOCATED ROOM THERMOSTAT, ELECTRICR EXISTING ROOM THERMOSTAT, ELECTRICE EXISTING DUCT TO BE REMOVED DUCT TRANSITION FROM RECTANGULAR TO ROUND DUCT OVER/UNDER ANOTHER DUCT CONICAL TAP FITTING SHOE TAP FITTING POINT OF NEW CONNECTION TO EXISTING SIDEWALL EXHAUST OR RETURN AIR GRILLE EXHAUST CEILING REGISTER OR GRILLE MANUAL VOLUME DAMPER (VD) EXISTING DUCT TO BE REMOVED 30° RISE(R)/DROP(D) IN DUCTWORK IN DIRECTION OF ARROW FIRE/SMOKE DAMPER (FSD) THROUGH WALL/ FLOOR CONNECT NEW DUCT TO EXISTING DUCT FIRE DAMPER (FD) THROUGH WALL/ FLOOR ECCENTRIC DUCT REDUCER CONCENTRIC DUCT REDUCER MOTOR OPERATED DAMPER EXISTING DUCT M ROOM THERMOSTAT DUCT SMOKE DETECTOR (DS) ROOM TEMPERATURE SENSORS DIFFUSER UNDER DUCT SIDEWALL SUPPLY REGISTER ROUND DIFFUSER SMALL RADIUS ELBOW LARGE RADIUS ELBOW RETURN DUCT -SECTION/ END VIEW SUPPLY DUCT -SECTION/ END VIEW EXHAUST DUCT -SECTION/ END VIEW RECTANGULAR DUCT, WIDTH x DEPTH (INCHES) CROSS SECTION THROUGH ROUND DUCT FLEXIBLE CONNECTION 12x8 W/1"AL FLEXIBLE DUCT ACOUSTICAL DUCT LINING OVAL DUCT (INCHES)12x8Ø ROUND DUCT (INCHES) 12x8 12Ø LINEAR DIFFUSER RETURN AIR CEILING GRILLE AND RETURN AIR CEILING GRILLE WITH SOUND BOOT VANED ELBOW (PROVIDE ALL SQUARE OR RECTANGULAR ELBOWS WITH VANES EXCEPT TRANSFER AIR SOUND ELBOW) CEILING DIFFUSERS (ARROWS DENOTE THROW PATTERN IF THROW IS SOMETHING OTHER THAN 4-WAY) SYMBOL DESCRIPTION SINGLE LINE DUCTWORK SYMBOL DESCRIPTIONSYMBOLDESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION AD BF CI CO CONT. DB D Db DIA. C EFF FB FD FD FCU ENT EXH FS GA GAL FLEX FT. FT HB HORZ HP KW IN HR F.G. AC AFF AL AMP BHP AP BOD BOP BTU BTUH BD CFM DBT DX °F FCO FPM FPS GPH FSD GPM HD KWH KVA EMCS NC. MIN LBS MAX OA NTS QTY QUAD RA SA S.DPR. RM REQ SPEC ST TEMP TSTAT TYP V SQ WB Z VEL VERT MA MCC N/A NIC #,NO. NO NC OBD PRV PSI PD PSIG RH RPM SCD SDVV VAC VTR WCO WH VAV SP TP ZONE TOTAL PRESSURE (INCHES OF WATER) STATIC PRESSURE (INCHES OF WATER) VARIABLE AIR VOLUME WALL HYDRANT WALL CLEANOUT VENT THRU ROOF VOLTS, ALTERNATING CURRENT SINGLE DUCT VARIABLE VOLUME SMOKE CONTROL DAMPER REVOLUTIONS PER MINUTE RELATIVE HUMIDITY POUNDS PER SQUARE INCH GAUGE PRESSURE DROP POUNDS PER SQUARE INCH PRESSURE REDUCING VALVE OPPOSED BLADE DAMPER NORMALLY CLOSED NORMALLY OPEN NUMBER (QUANTITY) NOT IN CONTRACT NOT APPLICABLE MOTOR CONTROL CENTER MAIN AIR (CONTROLS) VERTICAL VELOCITY WET BULB SQUARE VOLTS TYPICAL THERMOSTAT TEMPERATURE SOUND TRAP SPECIFICATION REQUIRED ROOM SMOKE DAMPER SUPPLY AIR RETURN AIR QUADRANT QUANTITY NOT TO SCALE OUTSIDE AIR MAXIMUM POUNDS MINIMUM NOISE CRITERIA ENERGY MANAGEMENT CONTROL SYSTEM KILOVOLT-AMPERE KILOWATT HOUR HAND DAMPER (VOLUME DAMPER) GALLONS PER MINUTE FIRE/SMOKE DAMPER GALLONS PER HOUR FEET PER SECOND FEET PER MINUTE FLOOR CLEANOUT DEGREES FAHRENHEIT DIRECT EXPANSION DRY BULB TEMPERATURE CUBIC FEET PER MINUTE BACKDRAFT DAMPER BTU PER HOUR BRITISH THERMAL UNIT BOTTOM OF PIPE BOTTOM OF DUCT ACCESS PANEL BRAKE HORSE POWER AMPERE (AMPS) ACOUSTICAL LINING ABOVE FINISHED FLOOR AIR CONDITIONING UNIT FILTER GAUGE HOUR(S) INCHES KILOWATT HORSEPOWER HORIZONTAL HOSE BIBB FLAT TOP FEET FLEXIBLE GALLONS GAUGE FLOOR SINK EXHAUST ENTERING FAN COIL UNIT FIRE DAMPER FLOOR DRAIN FLAT BOTTOM EFFICIENCY CELSIUS DIAMETER DECIBEL DRAIN DRY BULB CONTINUATION CLEANOUT CAST IRON BELOW FLOOR ACCESS DOOR ABBREVIATION DESCRIPTION XX XX X * * FLEXIBLE DUCT UC UNDERCUT SYMBOLS LIST NOTES A. DESIGN HEATING AND COOLING LOADS FOR THE BUILDING HAVE BEEN CALCULATED USING CARRIER HAP USING PROCEDURES RECOMMENDED BY ASHRAE. B. ALL EQUIPMENT AND SYSTEMS HAVE BEEN SIZED TO BE NO GREATER THAN NEEDED TO MEET CALCULATED LOADS. C. HUMIDIFICATION SYSTEMS HAVE NOT BEEN PROVIDED ON THIS PROJECT. D. EACH HEATING OR COOLING SYSTEM ZONE HAS BEEN PROVIDED WITH ITS OWN TEMPERATURE CONTROL DEVICE. E. THE PROGRAMMABLE THERMOSTATS SHALL BE CAPABLE OF SETTING BACK TEMPERATURE TO 55 DEGREES F DURING HEATING AND SETTING UP TO 85 DEGREES F DURING COOLING, CAPABLE OF AUTOMATICALLY SETTING BACK OR SHUTTING DOWN SYSTEMS DURING UNOCCUPIED HOURS USING 7-DIFFERENT DAY SCHEDULES, HAVE A ACCESSIBLE MANUAL 2-HOUR OVERRIDE THAT ALLOWS TEMPORARY OPERATION OF THE SYSTEM FOR UP TO 2 HOURS, HAVE A BATTERY BACK-UP CAPABLE OF MAINTAINING PROGRAMMED SETTINGS FOR AT LEAST 10 HOURS WITHOUT POWER. A SETBACK OR SHUTOFF CONTROL IS NOT REQUIRED ON THERMOSTATS THAT CONTROL SYSTEMS SERVING AREAS THAT OPERATE CONTINUOUSLY SUCH AS THE ELEVATOR EQUIPMENT ROOM AND ELECTRICAL ROOMS IF APPLICABLE. F. OUTDOOR-AIR SUPPLY SYSTEMS WITH DESIGN AIRFLOW RATES GREATER THAN 3000 CFM AND ALL EXHAUST SYSTEMS MUST HAVE DAMPERS THAT ARE AUTOMATICALLY CLOSED WHILE EQUIPMENT IS NOT OPERATING IF APPLICABLE. G. OUTSIDE VENTILATION HAS BEEN DESIGNED PER 2021 WSMC. H. ALL SUPPLY AND RETURN AIR DUCTS MUST BE INSULATED W ITH A MINIMUM OF R-6 (2" MINIMUM THICKNESS DUCT WRAP OR 1-1/2" WHEN DUCT IS LINED). ALL DUCTS LOCATED OUTSIDE THE BUILDING MUST BE INSULATED WITH A MINIMUM OF R-8. I. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS, MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS, MESH AND MASTIC SEALING SYSTEMS, OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 181B. J. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT, INCLUDING MULTIPLE-ZONE TERMINAL UNITS. K. OPERATOR AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES EQUIPMENT INPUT AND OUTPUT CAPACITY AND REQUIRED MAINTENANCE ACTIONS, EQUIPMENT OPERATION AND MAINTENANCE MANUALS, HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS. DESIRED OR FIELD DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON THE CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. A COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. L. EACH SUPPLY AIR OUTLET OR DIFFUSER MUST HAVE ITS OW N BALANCING DEVICE. ACCEPTABLE BALANCING DEVICES INCLUDE ADJUSTABLE DAMPERS LOCATED WITHIN THE DUCTWORK AND SUPPLY AIR DIFFUSERS. M. WATER-HEATING EQUIPMENT AND HOT WATER STORAGE TANKS SHALL MEET THE REQUIREMENTS OF TABLE 404.2 OF THE 2021 WSEC. THE EFFICIENCY SHALL BE VERIFIED THROUGH DATA FURNISHED BY THE MANUFACTURER OR THROUGH CERTIFICATION UNDER AN APPROVED CERTIFICATION PROGRAM. N. SERVICE WATER-HEATING EQUIPMENT MUST BE PROVIDED WITH CONTROLS THAT ALLOW THE USER TO SET WATER TEMPERATURE TO 100 DEGREES F FOR DWELLING UNITS AND 90 DEGREES F FOR OTHER OCCUPANCIES. CONTROL MUST LIMIT OUTPUT TEMPERATURES OF LAVATORIES IN PUBLIC FACILITY REST ROOMS TO 110 DEG REES F. O. WATER-HEATING EQUIPMENT NOT PROVIDED WITH INTEGRAL HEAT TRAPS AND SERVING NON-CIRCULATING SYSTEMS SHALL BE PROVIDED WITH HEAT TRAPS ON THE SUPPLY AND DISCHARGE PIPING ASSOCIATED WITH THE EQUIPMENT. P. FOR AUTOMATIC-CIRCULATING HOT WATER SYSTEMS, PIPING SHALL BE INSULATED WITH 1" OF INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU-IN/(H xFT2x°F). THE FIRST 8'-0" OF PIPING IN NON- CIRCULATING WATER HEATING SYSTEMS SERVED BY EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS SHALL BE INSULATED WITH 1/2" PIPE INSULATION OF MATERIAL HAVING CONDUCTIVITY NOT EXCEEDING 0.27 BTU-IN/(H xFT2x°F). DUCT SMOKE DETECTOR TESTING T T DS A CFM X TYP # TYPICAL OF NUMBER SHOWN ON SYSTEM, OR INSTALL NOTE. A. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN FURRED CHASES OR SUSPENDED CEILINGS, UNLESS OTHERWISE NOTED. B. PROVIDE ACCESS PANELS OR DOORS IN UNACCESSIBLE CEILINGS AND/OR CHASES FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, COILS, FANS, CONTROLS, ETC. ACCESS DOOR RATING SHALL MATCH CLASSIFICATION OF WALL AND CEILING FIRE RATING. C. COORDINATE THE LOCATION OF ALL DIFFUSERS, GRILLES, REGISTERS, ACCESS DOORS, ETC., WITH THE ARCHITECTURAL REFLECTED CEILING PLAN(S). D. ALL ROUND RUNOUTS AND DROPS TO DIFFUSERS SHALL BE THE SAME NOMINAL SIZE AS THE SCHEDULED DIFFUSER NECK SIZE. E. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. ALL DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE DIMENSIONS. F. PROVIDE TURNING VANES IN ALL SQUARE ELBOWS. EXCEPT TRANSFER AIR SOUND ELBOWS. G. THE CFM OF EACH DIFFUSER, REGISTER, ETC., IS INDICATED IN THE SYMBOL DESIGNATION ON THE DRAWINGS. H. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE RATED AND/OR SMOKE RATED WALLS AND ASSEMBLIES. PROVIDE APPROVED FIRE AND FIRE/SMOKE DAMPERS IN ALL REQUIRED PENETRATIONS FOR DUCTWORK, GRILLES, REGISTERS AND DIFFUSERS. ALL PIPE AND DUCTWORK PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIG HT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL. I. CONTRACTOR SHALL COORDINATE ALL DUCTWORK, PIPING, PLUMBING AND FIRE PROTECTION PIPING WITH STRUCTURAL AND ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY. J. CONTRACTOR SHALL FURNISH ALL NECESSARY STRUCTURES, INSERTS, SLEEVES, AND HANGING DEVICES FOR INSTALLATION OF MECHANICAL AND PLUMBING EQUIPMENT, DUCTWORK AND PIPING, ETC. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND ALL BUILDING TRADES TO AVOID CONFLICTS AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY. K. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY MISCELLANEOUS ANGLES, CHANNELS, UNISTRUT, ETC., AS MAY BE REQUIRED TO ADEQUATELY SUPPORT THE MECHANICAL PIPING, DUCTWORK, AND EQUIPMENT IN A MANNER APPROVED BY THE ARCHITECT WHICH WILL NOT OVERLOAD THE BUILDING STRUCTURAL SYSTEM. L. CONTRACTOR SHALL PROVIDE RETURN AIR OR TRANSFER AIR OPENINGS IN FULL HEIGHT WALLS SIZED AT 500 FPM (UNLESS OTHERWISE SPECIFICALLY SHOWN ON THE DRAWINGS) TO CREATE AND/OR MAINTAIN A RETURN AIR PATH AS REQUIRED. FIRE DAMPERS AND/OR SMOKE DAMPERS SHALL BE PROVIDED IN SUCH OPENINGS WHERE REQUIRED BY NOTE "H". M. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, DUCT WALL PENETRATIONS AND FITTING CONNECTIONS ON ALL DUCT SYSTEMS. 2021 WASHINGTON STATE BUILDING CODE (WSBC), 2021 WASHINGTON STATE MECHANICAL CODE (WSMC), 2021 WASHINGTON STATE ENERGY CODE (WSEC) AND 2021 WASHINTON STATE PLUMBING CODE (WSPC). ALL SYSTEMS SHALL BE IN COMPLIANCE WITH THE ABOVE CODES AS ADOPTED BY THE CITY OF YELM, WA OUTDOOR AIR VENTILATION PROVIDED AND BASED ON CHAPTER 4, SECTION 403.2 AND TABLE 403.3. SEE SHEET M1.2.2 FOR VENTILATION CALCULATIONS. ALL ROOFTOP EQUIPMENT SHALL BE PERMANENTLY IDENTIFIED AS TO THE AREA SERVED WITH A RUST-PROOF METAL NAMEPLATE PER 2021 WSMC. DUCT SMOKE DETECTORS REQUIRED BY 2021 WSMC SECTION 606 SHALL BE INSTALLED IN THE RETURN DUCTWORK AS SHOWN ON THE PLANS PER WSMC 606.2.1, 606.2.2, 606.3, AND NFPA 72. IF A FIRE ALARM SYSTEM IS AVAILABLE, THAT THE DUCT SMOKE DETECTOR(S) SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM (WSMC 606.4.1) AND IF A FIRE ALARM SYSTEM IS NOT AVAILABLE, PROVIDE A VISIBLE AND AUDIBLE SUPERVISORY SIGNAL AT A CONSTANTLY SUPERVISED LOCATION TRIGGERED BY THE ACTIVATION OF A DUCT SMOKE DETECTOR. INCLUDE THE AIR DUCT DETECTOR TROUBLE INDICATOR (LED AT THE CEILING BELOW THE DUCT DETECTOR) AS REQUIRED BY WSMC 606.4.1, EXCEPTION 2. EQUIPMENT AND APPLIANCES SHALL BE INSTALLED AS REQUIRED BY THE TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING, THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND THIS CODE. MANUFACTURERS INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON THE JOB SITE AT THE TIME OF INSPECTION PER WSMC SECTION 304.1. ACCESS TO ROOF MOUNTED EQUIPMENT COMPLIES WITH 2021 WSMC. SEE ARCHITECTURAL DRAWINGS FOR ROOF ACCESS DETAILS. 1. SYMBOLS LISTS, NOTES, ABBREVIATIONS, ETC. ARE FOR GENERAL REFERENCE ONLY. THE PRESENCE OF SYMBOLS, NOTES, ABBREVIATIONS, ETC. DOES NOT IMPLY ITS USE ON THIS PROJECT. REFER TO DRAWINGS FOR SPECIFIC SYMBOLS, NOTES, ABBREVIATIONS, ETC. USED. TESTING AND INSPECTION OF SMOKE CONTROL DEVICES A.PRIOR TO TESTING SMOKE CONTROL DEVICES: 1.VERIFY PROPER OPERATION OF EACH EXISTING SMOKE DETECTOR. ACTIVATION TESTING SHALL BE PERFORMED USING "CANNED SMOKE" ACCEPTABLE TO THE AUTHORITIES HAVING JURISDICTION. 2.VERIFY ACTIVATION OF THE EXISTING SMOKE DETECTOR SHUTS DOWN THE APPROPRIATE AIR-MOVING SYSTEM(S). VERIFY ACTIVATION OF THE SMOKE DETECTOR IS SHOWN BY THE FIRE ALARM SYSTEM WHERE MONITORING IS REQUIRED. B.INSPECTION & TESTING OF SMOKE CONTROL DEVICES: 1.TESTING OF FIRE/SMOKE DAMPERS AND SMOKE DETECTORS SHALL BE ACCOMPANIED BY THE ELECTRICIAN AND/OR THE CONTROLS SYSTEM SUPPLIER. IF THE BUILDING HAS A FIRE ALARM SYSTEM, A REPRESENTATIVE OF THE MANUFACTURER MUST BE PRESENT DURING THE TESTING. AN AIR BALANCE REPORT SHOWING FRESH AIR COMPLIANCE IS REQUIRED BY THE MECHANICAL INSPECTOR FOR FINAL INSPECTION APPROVAL. VENTILATION SYSTEMS SHALL BE BALANCED BY AN APPROVED METHOD. A BALANCE REPORT SHALL VERIFY THAT THE VENTILATION SYSTEM IS CAPABLE OF SUPPLYING AIRFLOW RATES REQUIRED BY SECTION 403 (2021 WSMC SECTION 403.3). VENTILATION VERIFICATION ? - --- H HUMIDISTAT REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.2.4 PROJECT NUMBER: 24212 MECHANICAL - NOTES CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST RTU1 T# 1 18/8 22/2 LOW CAPACITANCE COMM CABLE VICONICS 8650 THERMOSTAT BY EMS SUPPLIER. EDGE 534 R R R R R 18/2 WALK-IN COOLER SENSOR BEER CAVE SENSOR WALK-IN DAIRY SENSOR WALK-IN FREEZER SENSOR REAR FREEZER SENSOR INSIDE CPI PANEL NETWORK SWITCH CAT5E EMS CABLE SPECIFICATIONS 18/2 TSP -WINDY CITY #002352-S OR EQUAL 22/2 TSP -WINDY CITY #043004AL OR EQUAL NOTE:ALL WIRING TO BE CONTINUOUS, WITH NO SPLICES AND LABELED ON BOTH ENDS. S# 1 RS # 1 18/2 18/2 RETURN SENSORS SUPPLY SENSORS ROOFTOP UNIT RTU SETPOINTS COOLING HEATING HUMIDITY RTU-1 74°F 68°F 55%RH THERMOSTAT WIRING FROM RTU TO THERMOSTAT LOCATION BY MECHANICAL CONTRACTOR. FINAL CONNECTION TO THERMOSTAT BY EMS SUPPLIER. OAU1 OAU1 IS INTENDED TO OPERATE CONTINUOUSLY WHILE BUILDING IS OCCUPIED TO MEET BOTH VENTILATION AND EXHAUST REQUIREMENTS. SUPPLY AIR SHALL BE NEUTRAL (~70F DB, 55% RH) COORDINATE FIELD INSTALLED SENSOR REQUIREMENTS WITH EMS SUPPLIER AND OWNER 1. REFERENCE MECHANICAL NOTES SHEET AND MECHANICAL SPECIFICATIONS FOR CONTROLS INFORMATION. 2. TERMINATIONS SHALL BE MADE IN ACCORDANCE WITH EMS SUPPLIER INSTRUCTIONS. NO FOIL OR UNUSED WIRE(S) SHALL BE EXPOSED AFTER APPLICATION OF HEAT SHRINK. 3. MINOR CHANGES IN MATERIALS OR TERMINATION POINTS SHALL NOT INCREASE CONTRACT COST. 4. ROUTE EMS CONDUITS CONCEALED IN SALES AREA. GENERAL EMS NOTES REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.2.5 PROJECT NUMBER: 24212 ENERGY MANAGMENT SYSTEM CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS N.T.S. 1 EMS RISER OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST MECHANICAL SPECIFICATIONSSECTION 1. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL VENTILATOR(S) AND/OR EXHAUST FAN(S) AS SHOWN AND SCHEDULED. THE UNIT(S) SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, AND SHALL PERFORM AT THE CONDITIONS SCHEDULED. 2. INSTALL VENTILATOR(S) AND/OR EXHAUST FAN(S) WITH CLEARANCES FOR SERVICE AND MAINTENANCE. 3. THE MECHANICAL CONTRACTOR SHALL PROVIDE ONE (1) BACKDRAFT DAMPER FOR EACH VENTILATOR AND/OR EXHAUST FAN, OR SHALL VERIFY A BACKDRAFT DAMPER HAS BEEN FACTORY INSTALLED. 4. THE MECHANICAL CONTRACTOR SHALL ADJUST DAMPER LINKAGES FOR PROPER OPERATION. 15853 POWERED VENTILATORS 1. ALL DUCTWORK SHALL BE CONSTRUCTED FROM HOT NEW DIPPED GALVANIZED SHEET IRON OR STEEL, ASTM A-120, IN COMPLIANCE WITH 2021 W.S.M.C. CHAPTER 6, AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS FOR GAGE AND REINFORCEMENT. ALL DUCTWORK SHALL BE SEALED AND INSULATED IN ACCORDANCE WITH IECC. 2. ALL LOW VELOCITY AIR CONDITIONING SUPPLY AIR AND RETURN AIR DUCTWORK SHALL BE 2-INCH DUCT CONSTRUCTION. CONSTRUCT AND ERECT DUCTWORK IN ACCORDANCE WITH THE CURRENT ISSUES OF THE WSMC, SMACNA STANDARDS AND ASHRAE HANDBOOKS. DUCTS SHALL CONFORM TO DIMENSIONS ON THE DRAWINGS UNLESS LOCATION OF STRUCTURAL MEMBERS PROHIBITS. IN CASE OF CHANGE IN DIMENSIONS, CROSS SECTIONAL AREAS SHALL BE MAINTAINED. 3. ROUND FLEX DUCT SHALL BE USED FOR DIFFUSER-GRILL CONNECTIONS ABOVE LAY-IN CEILINGS. FLEXDUCT MAY BE USED IN OTHER AREAS WHERE THE DUCT AND GRILLE ARE PERMANENTLY AND REASONABLY ACCESSIBLE. MAXIMUM FLEX DUCT LENGTH IS 5'-0'' AND THE DUCTWORK SHALL BE PRE-LINED WITH 1" INSULATION. PERFORMANCE OF FLEXIBLE DUCT SHALL MEET OR EXCEED THE RIGID DUCTWO RK. 4. FLEXIBLE DUCTS SHALL BE THERMAFLEX II TYPE M-KE, FACTORY FABRICATED ASSEMBLY, SPIRAL CONSTRUCTION, FIBERGLASS BLANKET INSULATION (R=6.0), AND MYLAR SHEATH. FLEXIBLE DUCTS UL LISTED FOR CLASS 0 DUCT AND COMPLY WITH NFPA-90A. 5. PAINT ALL DUCTWORK, TURNING VANES, INSULATION ECT., THAT IS VISIBLE THROUGH GRILLES, REGISTERS, OR CEILING DIFFUSERS FLAT BLACK. 6. TAPE ALL JOINTS IN SHEET METAL DUCTWORK WITH ARABOL AND CANVAS OR EQUAL ADHESIVE. 7. FLEXIBLE CONNECTIONS SHALL BE 30 OUNCE, CLOSELY WOVEN, NEOPRENE COATED GLASS FABRIC THAT IS FIRE RETARDENT, WEATHERPROOF AND AIRTIGHT, A MINIMUM OF 6" WIDTH. 8. FABRICATE ALL SHEET METAL DUCTS OF PRIME GRADE, LOCKING FORMING QUALITY GALVANIZED STEEL SHEETS USING GAUGES OF METAL AND REINFORCING BETWEEN JOINTS AS FOLLOWS A. 12" AND SMALLER (LONGEST SIDE)-24 GAUGE B. 13"-18" (LONGEST SIDE) - 24 GAUGE. C. 19"-30" (LONGEST SIDE) - 24 GAUGE, WITH 1"x1"x1/8" ANGLES AT 5 FT. ON CENTER D. 31"-42" (LONGEST SIDE) - 22 GAUGE, WITH 1"x1"x1/8" ANGLES AT 5 FT. ON CENTER 9. DUCT LINER SHALL HAVE A FLAME SPREAD AND SMOKE DEVELOPMENT 25 OR LESS AND 50 OR LESS WHEN TESTED BY ASTM E-84 (NFPA 255) METHOD. 10. INSULATE THE FIRST 10 FEET OF ALL RECTANGULAR SUPPLY AIR AND ALL RECTANGULAR RETURN AIR SHEET METAL DUCTWORK INTERNALLY WITH JOHNS-MANVILLE LINACOUSTIC RC FIBERGLASS DUCT LINER WITH REINFORCED COATING SYSTEM, THICKNESS 1" (R=6.0) AND DENSITY 1-1/2 PCF. ALL OTHER RECTANGULAR SUPPLY AIR AND RIGID ROUND DUCTWORK SHALL BE INSULATED WITH 2" THICK (R=6.0) JOHNS-MANVILLE MICROLITE DUCT WRAP WITH FSK VAPOR BARRIER. 15891 METAL DUCTWORK SYSTEMS 1. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING VOLUME DAMPERS, TURNING VANES, ACCESS DOORS, VIBRATION ISOLATORS, ETC. 2. THE ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS. 15910 DUCT ACCESSORIES 15975 TEMPERATURE CONTROLS 1. THE MECHANICAL CONTRACTOR SHALL SUBCONTRACT AN AIR BALANCER TO BALANCE THE SYSTEMS DESCRIBED BELOW. 2. THE BALANCING SHALL BE COMPLETED BY AN INDEPENDENT AIR BALANCER WHO IS NOT AN EMPLOYEE OF THE MECHANICAL CONTRACTOR. 3. THE BALANCING SHALL BE DONE BY A QUALIFIED AIR BALANCER THAT HAS AT LEAST (3) YEARS OF DOCUMENTED AIR BALANCING EXPERIENCE. 4. PER COMPLIANCE WITH IECC, THE BALANCER SHALL SUBMIT AN AIR BALANCE REPORT TO THE ENGINEER AND CITY INSPECTOR. 5. THE BALANCE REPORT SHALL SHOW PROOF THAT THE SYSTEM HAS BEEN BALANCED TO +/- 5% OF THE DESIGNED AIRFLOW. IT IS THE MECHANICAL CONTRACTOR AND AIR BALANCER'S DUTY TO PROVIDE ACCURATE DATA, SO AREAS OF INCORRECT FLOW MAY BE DISCLOSED TO THE ENGINEER, INSPECTOR, AND OWNER. 6. ALL AIRSIDE SYSTEMS, COMPONENTS, ETC. INCLUDING SUPPLY, RETURN, OUTDOOR, AND EXHAUST AIR SYSTEMS SHALL BE BALANCED. THE BALANCER SHALL PROVIDE SHEAVES AND BELTS AS NEEDED TO PROPERLY BALANCE EQUIPMENT TO +/- 5% OF THE DESIGNED AIRFLOWS. ALL DIFFUSERS, REGISTERS, GRILLES, AND LOUVERS SHALL BE INDIVIDUALLY BALANCED AND LISTED IN THE BALANCE REPORT. ALL AIRSIDE EQUIPMENT, SUPPLY, RETURN, AND OUTDOOR AIR FLOWRATES SHALL BE LISTED IN THE BALANCE REPORT. 15990 TESTING, ADJUSTING, AND BALANCING 15010 BASIC MECHANICAL REQUIREMENTS MECHANICAL SPECIFICATIONSSECTION 15140 SUPPORTS AND ANCHORS 1. FURNISH PIPE AND DUCT HANGERS, WHERE REQUIRED, FIRMLY SUPPORTED FROM BUILDING STEEL, CONCRETE OR MASONRY STRUCTURE. 2. SUPPORT PIPING SYSTEMS SECURELY WHILE ALLOWING FOR PIPE AND BUILDING EXPANSION AND CONTRACTION. PROVIDE COPPER PLATED HANGERS FOR COPPER PIPE. USE ADJUSTABLE STEEL BAND HANGERS. MAXIMUM SPACING SHALL BE 5' FOR 1/2" PIPING, 7' FOR 3/4'' TO 1-1/4" PIPING, AND 9' FOR 1-1/2" PIPING. 3. FURNISH MECHANICAL EQUIPMENT SUPPORTS AS DETAILED OR AS REQUIRED TO SAFELY AND PERMANENTLY CARRY THE WEIGHT OF THE EQUIPMENT. 1. INSULATE ALL METAL SUPPLY AND RETURN DUCTWORK WITH 2'' FOIL BACKED FIBERGLASS INSULATION. IN UNHEATED ATTICS OR IN AREAS LOCATED ABOVE THE LINE OF BUILDING INSULATION, INSULATE ALL DUCTWORK, INCLUDING RETURN AIR AND EXHAUST AIR DUCTWORK, WITH 3'' FOIL-BACKED INSULATION, AND REQUEST THAT GENERAL CONTRACTOR BLOW ATTIC INSULATION OVER THE TOP OF THE INSULATED DUCTWORK, EXPOSED SPIRAL DUCTWORK, OR DUCTWORK LOCATED WITHIN A HEATED SPACE DOES NOT REQUIRE INSULATION. 2. LINE ALL SUPPLY AND RETURN DUCTWORK WITHIN FIFTEEN (15) FEET OF SUPPLY FAN WITH 1/2" DUCT LINER TO REDUCE SOUND. 3. ALL INSULATION MATERIALS TO HAVE A FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPMENT RATING OF 50 OR LESS AS TESTED BY ASTM E-84, UL-723, NFPA 90A-90-B. 15250 MECHANICAL INSULATION 1. THE OWNER SHALL FURNISH AND GENERAL CONTRACTOR SHALL INSTALL PACKAGED ROOF-TOP UNIT(S) AS SHOWN AND SCHEDULED. THE UNIT(S) SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, AND SHALL PERFORM AT THE CONDITIONS SCHEDULED. 2. THE MECHANICAL CONTRACTOR SHALL PROVIDE TWO (2) SETS OF FILTERS FOR EACH UNIT AND SHALL BE RESPONSIBLE FOR CHANGING FILTERS WITHIN TWO (2) WEEKS OF START-UP. 3. THE MECHANICAL CONTRACTOR SHALL PROVIDE A SINGLE POWER SOURCE CONNECTION DISCONNECT AND A 15 AMP DUPLEX, WEATHERPROOF CONVENIENCE OUTLET BOX FOR EACH ROOF TOP UNIT INSTALLED. 15782 ROOF-TOP UNITS 1. CONDENSATE DRAIN PIPING SHALL BE ASTM B-88, TYPE "M" HARD DRAWN COPPER WITH WROT COPPER FITTINGS AND SOLDERED JOINTS, 50/50 SOLDER. INSULATE WITH 1/2" THICK FLEXIBLE CLOSED CELL FOAMED PLASTIC PIPE INSULATION, ARMSTRONG ARAMFLEX, OR EQUAL FOR ENTIRE LENGTH. FITTINGS FIELD FABRICATED OF NESTING SIZES, SECURED WITH ADHESIVE. REFRIGERANT SUCTION LINES SHALL BE INSULATED TO 1" THICKNESS. 2. ALL PIPING SHALL CONFORM TO ASTM B88-72. 3. FITTINGS SHALL WROUGHT COPPER, DRAINAGE TYPE FOR LINES 1-1/4" AND LARGER. SOLDER WITH 50/50 SOLDER. 15783 CONDENSATE AND COOLER DRAINS 1. ALL WORK TO BE DONE AND MATERIALS FURNISHED COMPLYING WITH APPLICABLE LAWS, AND RESOLUTIONS, INCLUDING THE CURRENTLY ENFORCED VERSIONS OF THE INTERNATIONAL MECHANICAL CODE (IMC), INTERNATIONAL PLUMBING CODE (IPC), INTERNATIONAL BUILDING CODE (IBC), AND LOCAL, STATE, AND FEDERAL FIRE SAFETY CODES (NFPA). 2. ALL MATERIALS USED SHALL BE NEW AND UNDAMAGED. 3. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH CURRENT CONSTRUCTION INDUSTRY STANDARDS AND WORKMANSHIP. 4. PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO ENSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. 5. AT SUBSTANTIAL COMPLETION OF THE CONSTRUCTION, FURNISH AS-BUILT PLANS TO ARCH/ENGINEER FOR APPROVAL BEFORE THEY ARE TURNED OVER TO OWNER 6. ALL MANUFACTURED EQUIPMENT, ACCESSORIES AND MATERIALS SHALL BE USED AS INTENDED BY THE MANUFACTURER, IN STRICT ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS. 7. THE MECHANICAL CONTRACTOR SHALL PROVIDE, IN ADDITION TO ANY OTHER WARRANTIES SPECIFIED, A ONE(1) YEAR FULL LABOR AND MATERIAL WARRANTY ON ALL WORKMANSHIP, MATERIAL AND EQUIPMENT FURNISHED FOR THIS PROJECT. THE CONTRACTOR SHALL REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT, AND MATERIALS WITHOUT ADDITIONAL CHARGES, INCLUDING ALL REFRIGERANT CAUSED TO BE LOST BY REPAIR OF DEFECTIVE WORK OR MATERIALS. 8. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR INSTRUCTING THE OWNER IN PROPER OPERATION AND MAINTENANCE OF THE EQUIPMENT. A WIRING DIAGRAM WITH INSTRUCTIONS FOR THE OPERATIO N, INSTALLER'S NAME, PHONE NUMBER, MODEL, AND MAKE OF EQUIPMENT PROVIDED, ETC., SHALL BE FURNISHED TO OWNER. AT A TIME DESIGNATED, PROVIDE AN ENGINEER OR MECHANIC TO GO OVER SYSTEM WITH OWNER'S REPRESENTATIVE TO THOROUGHLY FAMILIARIZE HIM WITH THE OPERATION AND MAINTENANCE OF THE SYSTEM. 9. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL OPENINGS AND REQUIRED LINTELS NEEDED FOR GENERAL CONTRACTOR FOR THE INSTALLATION OF MECHANICAL EQUIPMENT. 10. SAWCUTS, LINTELS, HEADERS, AND STRUCTURAL MODIFICATIONS TO THE BUILDING STRUCTURE NEEDED FOR THE INSTALLATION OF MECHANICAL EQUIPMENT SHALL BE APPROVED BY THE GENERAL CONTRACTOR, BEFORE INSTALLATION. 11. IN GENERAL, OPENINGS AND REQUIRED LINTELS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING DETAILS AND TEMPLATES OF ALL OPENINGS NECESSARY FOR MECHANICAL EQUIPMENT INSTALLATION INCLUDING: HOUSING, ACCESS DOORS, INSPECTION DOORS, AND PASSAGE WAYS FOR MECHANICAL EQUIPMENT. THE MECHANICAL CONTRACTOR iS RESPONSIBLE FOR SEALING CRACKS AND FINISHING ROUGH EDGES LEFT FOLLOWING MECHANICAL INSTALLATION. 12. THE USE OF THE MECHANICAL EQUIPMENT FOR HEATING, COOLING, OR DRYING DURING CONSTRUCTION IS PROHIBITED, UNLESS APPROVED BY WRITTEN DOCUMENTATION BY THE OWNER. 13. ALL OTHER MANUFACTURERS BESIDES THE SPECIFIED PRODUCT MUST BE PRE-APPROVED PRIOR TO BIDDING. SUBMIT DETAILED EQUIPMENT CUT- SHEETS AND CLEARLY IDENTIFY ANY DIFFERENCES FROM THE SPECIFIED PRODUCT. ANY EQUIPMENT SUBMITTED DURING THE REGULAR SUBMITTAL PROCESS THAT WAS NOT PRE-APPROVED WILL BE AUTOMATICALLY BE REJECTED. 14. PERMITS AND INSPECTIONS: MECHANICAL CONTRACTOR IS RESPONSIBLE TO OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND LICENSES. WHEN REQUIRED BY CODE, ALL WORK MUST BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TO FINAL APPROVAL, FURNISH THE ARCHITECT/OWNER WITH CERTIFICATES OF INSPECTION AND APPROVALS BY LOCAL AUTHORITIES. 15. PRIOR TO SUBMITTING BID, THE MECHANICAL CONTRACTOR SHALL CAREFULLY EXAMINE THE PLANS FOR THE PROPER FITTING OF THE MATERIAL AND APPARATUSES INTO THE BUILDING. ARRANGE WORK SCHEDULE FOR MINIMUM INTERFERENCE WITH THE WORK OF OTHER TRADES. SHOULD THE PARTICULAR EQUIPMENT PROPOSED FOR INSTALLATION REQUIRE OTHER ARCHITECTURAL, STRUCTURAL, PLUMBING, OR ELECTRICAL CONDITIONS THAT THOSE SHOWN, ARRANGE FOR SUCH SPACE BEFORE SUBMITTING BID. ALL CHANGES NECESSITATED BY THE FAILURE TO COMPLY WITH THIS CLAUSE, SHALL BE MADE AT NO ADDED EXPENSE TO THE OWNER. 16. WITHIN 10 DAYS AFTER AWARD OF CONTRACT, SUBMIT (4) COPIES OF A COMPLETE WRITTEN LIST OF ALL MAJOR ITEMS OF EQUIPMENT AND MATERIALS AS WELL AS ADDITIONAL COPIES, THAT THE CONTRACTOR MAY NEED RETURNED. THE SUBMITTAL SHALL DEFINITELY AND CLEARLY STATE WHERE SUBMITTED EQUIPMENT DOES NOT AGREE WITH THE CONTRACT DOCUMENTS, AND LIST DEVIATIONS IN COLOR OTHER THAN RED. SUBMIT ALL ITEMS AT ONE TIME AND IN A NEAT AND ORDERLY MANNER. PARTIAL LISTS WILL NOT BE ACCEPTABLE. SUBMITTALS SHALL INCLUDE MANUFACTURER'S SPECIFICATIONS, PHYSICAL DIMENSIONS AND RATINGS OF ALL EQUIPMENT SUBMITTED. SUBMITTALS SHALL BE INDEXED, SEPARATED BY DIVIDERS, AND BOUND IN LOOSE LEAF RING BINDERS. 1. THE OWNER SHALL FURNISH OR CONTRACT A TEMPERATURE CONTROL CONTRACTOR TO FURNISH ALL MOTORS, DRIVES, CONTROLLERS INTEGRAL TO THE MECHANICAL EQUIPMENT SYSTEM, AND FACTORY MOUNTED CONTROLS FOR ALL MECHANICAL EQUIPMENT. 2. THE MECHANICAL CONTRACTOR OR CONTRACTED TEMPERATURE CONTROL CONTRACTOR SHALL FURNISH AND INSTALL ALL SWITCHES, FIRE STATS, FREEZE STATS, THERMOSTATS, RELAYS, TIMERS, CONTROL CABINETS, AND OTHER SPECIALIZED EQUIPMENT PERTAINING TO MECHANICAL CONTROL. 3. THE ROOF MOUNTED UNITS (RTU#) SHALL BE CONTROLLED BY A PROGRAMMABLE THERMOSTAT WITH REMOTE TEMPERATURE SENSORS. A. THE TEMPERATURE CONTROLS SHALL BE ELECTRONIC, 7-DAY PROGRAMMABLE, WITH FUNCTION: AUTO, MANUAL, AND FAN ONLY, UNLESS SPECIFICALLY REQUESTED BY THE OWNER, AND SHALL BE PROVIDED BY THE CONTRACTED TEMPERATURE CONTROL CONTRACTOR. B. DEHUMIDIFICATION SYSTEMS SHALL BE CONTROLLED BY MANUFACTURER'S HUMIDISTAT. C. ALL CONTROL WIRING SHALL BE IN CONDUIT. CONDUIT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR LOCATION FOR CONDUITS. THE CONTRACTOR RESPONSIBLE TO INSTALL THE CONTROLS SHALL BE RESPONSIBLE TO PULL THE CONTROL WIRE. D. THE ROOF TOP UNIT SHALL UTILIZE TEMPERATURE CONTROL SYSTEM FURNISHED AS PART OF THE UNIT, OR SPECIFIED TO BE PROVIDED AS OPTIONS OR ACCESSORIES BY THE MANUFACTURER BY OF THE UNIT. ALL WIRING WILL BE DONE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS FURNISHED BY THE MANUFACTURER. 4. ELECTRICAL WIRING: ALL WIRING AND STARTERS ARE INCLUDED IN THE ELECTRICAL DIVISION OF THIS PROJECT, BUT ALL CONTROLS, RELAYS, ETC., ARE INCLUDED UNDER THIS DIVISION. ROOM THERMOSTATS AND CONTROL SWITCHES SHALL BE LOCATED AS SHOWN OR DIRECTED, AND ALL CONTROLS, RELAYS, STARTERS AND WIRING SHALL CONFORM TO THE CURRENTLY ENFORCED VERSION OF THE NATIONAL ELECTRICAL CODE (NEC). ALL CONTROLS SHALL BE FURNISHED AND PROPERLY IDENTIFIED, WITH INSTRUCTIONS FOR PROPER ELECTRICAL CONNECTIONS. RESPONSIBILITY FOR PROPER CONNECTIONS AND OPERATION IS INCLUDED HEREIN. REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.3 PROJECT NUMBER: 24212 MECHANICAL - SPECIFICATIONS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST A A B B 22 11 B504 B603 B603 B603 B603 CASHIER SALES FLOOR 2SALES FLOOR 1 BACK ROOMWALK-IN COOLER COLD VAULT STORAGE ROOMWALK-IN FREEZER MEN'S RESTROOM WOMEN'S RESTROOM HALLWAY STROBE ALARM OVER BACK DOOR 18" BELOW CEILING CONTROL PANEL IN CASHIER AREA. REF ELECTRICAL FOR CONDUIT LOCATIONS FOR ROUTING UNDER SLAB. *B603 B503 D AT 1' -0" AFF B503 N AT 8'-0" AFF *B501 B502 B503 N AT 8'-0" AFF PREP AREA SALES FLOOR 3 1. PRESSURED RELIEF DEVICES SHALL BE PIPED TO THE OUTDOORS WHERE THE DISCHARGE WILL NOT IMPINGE ON THE STRUCTURE, PERSONNEL, OR MEANS OF EGRESS AND WILL NOT CREATE A HAZARDOUS CONCENTRATION OF CARBON DIOXIDE. (NFPA 55, 13.1.1.2). THE TERMINATION OF THE PRESSURE RELIEF VENT DISCHARGE PIPING SHALL BE OUT DOORS AND A MINIMUM OF 10 FEET FROM THE OPENING INTO THE BUILDING. 2. CONTAINERS, CYLINDERS, AND TANKS SHALL BE PROVIDED WITH A PRESSURE GAUGE AND A LEVEL GAUGE OR DEVICE FOR INDICATING THE QUANTITY OF LIQUID CARBON DIOXIDE. (NFPA 55, 13.1.2.1) 3. ROOMS OR AREAS WHERE CONTAINER SYSTEMS ARE FILLED AND USED INDOORS OR IN ENCLOSED OUTDOOR LOCATIONS SHALL BE PROVIDED WITH A GAS DETECTION AND ALARM SYSTEM THAT IS CAPABLE OF DETECTING AND NOTIFYING THE BUILDING OCCUPANTS OF A GAS RELEASE THAT CREATES CARBON DIOXIDE VAPORS IN EXCESS OF ITS PEL. (NFPA 55, 13.2.2) 4. CARBON DIOXIDE GAS DETECTION SHALL BE AS FOLLOWS: A. PRE-ALARM (1500 PPM) NOTIFYING AY INCLUDE, BUT NOT LIMITED TO THE BUILDING OWNER, WORKING SUPERVISOR, OR MAINTENANCE COMPANY. B. ALARM (30,000 PPM) NOTIFICATION SHALL INCLUDE THE COMPLETE AREA, OR BUILDING EVACUATION AND ACTIVATION OF THE 911 SYSTEM, TO NOTIFY THE YELM FIRE DEPARTMENT OF A CARBON DIOXIDE GAS DETECTION ALARM. (PFD POLICY CARBON DIOXIDE 1.1) 5. CARBON DIOXIDE DETECTION SHALL BE LOCATED AT ALL POINTS OF USE LOCATIONS INSIDE THE BUILDING. (R3000.1) A. NOTE. THE DETECTION SHOULD BE PLACED AT A LEVEL ACCEPTABLE BASED ON THE PROPERTIES OF THE GAS (HEAVIER OR LIGHTER THAN AIR) 12-18 INCHES AFF OR BFC 6. ACTIVATION OF THE GAS DETECTION SYSTEM SHALL INITIATE AN AUDIBLE ALARM WITHIN THE ROOM OR AREA IN WHICH THE SYSTEM IS INSTALLED (NFPA 55, 13.2.2.1) 7. A WARNING SIGN SHALL BE POSTED AT THE ENTRANCE TO THE BUILDING, ROOM, ENCLOSURE, OR CONFINED AREA WHERE THE CONTAINER IS LOCATED. (NFPA 55, 13.2.3) 8. THE WARNING SIGN SHALL BE AT LEAST 8 IN. (200 MM) WIDE AND 6 IN. (150MM) HIGH AND STATE THE FOLLOWING: A. CAUTION: CARBON DIOXIDE GAS. VENTILATE THE AREA BEFORE ENTERING. A HIGH CARBON DIOXIDE (CO2) GAS CONCENTRATION IN THIS AREA CAN CAUSE SUFFOCATION. (NFPA 55, 13.2.3.1) 9. PROVIDE MINIMUM OF TWO NOTIFICATION DEVICES, ONE NEAR THE AREA/ROOM WHERE CYLINDER IS LOCATED, ON IN COMMON AREA WHERE THE PUBLIC GATHERS. DEVICES SHALL BE RATED AT 100 CD FOR VISUAL EFFECT AND 75 DB FOR AUDIBLE EFFECT UNLESS FULL FIRE ALARM IS PRESENT. (R3000.1) A. *NOTE - IF THE BUILDING IS EQUIPPED WITH A FIRE ALARM NOTIFICATION SYSTEM; THE USE OF THE SYSTEM IS ACCEPTABLE, PROVIDED THE GAS DETECTION HAS AUDIBLE AND VISIBLE CLEAR INDICATORS IN THE HAZARD AREA UPON BOTH THE WARNING LEVEL AND ALARM LEVEL OF THE GAS. 10. GAS DETECTION SYSTEM SHALL BE TIED INTO THE MONITORING SYSTEM IF PROVIDED (R3000.1) 11. PROVIDE LABEL ON PIPING TO INDICATE EXACT CONTENTS AND DIRECTION OF FLOW. THESE LABELS SHALL BE PLACED EVERY 20 FEET, MAJOR CHANGE IN DIRECTION AND WHERE PIPING ENTERS AND LEAVING WALLS. NOTES LEGEND * CO2 TANK TUBING SHUT OFF VALVE LOCATION B503 D B501 B603 B502 B503 N -POINT OF USE (BAG IN THE BOX) -CO2 TANK CABINET -DETECTION DEVICE -NOTIFICATION DEVICE (REPEATER) NOTE: SEE ALSO SHEET A1.5 & A3.2 FOR ADDITIONAL INFORMATION -CO2 CABINET B504 -CO2 SIGN, SEE DETAIL 2/A9.1 REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.4 PROJECT NUMBER: 24212 CO2 LAYOUT PLAN AND NOTES CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS 3/16" = 1'-0" 1 CO2 LAYOUT PLAN (FOR REFERENCE ONLY) OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY M1.5 PROJECT NUMBER: 24212 CO2 CUT SHEETS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS FOR INFORMATION ONLY OTP 11/12/24 A A B B 22 11 3" VTR 3" VTR 3" VTR 1 2 3 4 3 P417 5 2 P1.1 6 7 7 7 7 7 7 7 7 1 CD CD OAU1 RTU1 24 " ROOF HYDRANT, SEE SCHEDULES DUAL CHECK BACKFLOW BOOT COVER AND FLASHING SECURE CASING TO TOP AND BOTTOM CORDS OF BAR JOIST. (OR WOOD TRUSS) EXTEND DRAIN LINE FROM DRAIN PORT ON CLOSURE VALVE TO MOP SINK, FLOOR DRAIN OR OPEN FIXTURE WASTE WITH AIR GAP ROOF BAR JOIST (OR WOOD TRUSS) 3/4" COLD WATER SUPPLY REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY P1.1 PROJECT NUMBER: 24212 PLUMBING - ROOF PLAN CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS KEYNOTES 1 ROOF DRAINAGE WITH 4" LEADER. SEE DETAIL 9/A8.3. REFER TO ROOF DRAIN CALCULATION FOR SIZING INFO. 2 3" GREASE TRAP VENT. 3 3" VTR. MAINTAIN 10'-0" FROM ALL OUTDOOR AIR INTAKES. 4 3/4" CW UP FROM BELOW TO FREEZE LESS ROOF HYDRANT. 5 SATELLITE DISH LOCATION. REFERENCE THE ARCH ROOF PLAN FOR EXACT LOCATION. 6 EXTERIOR ROOF ACCESS SHOWN FOR REFERENCE ONLY, REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. 7 CONDENSING UNIT FOR REFRIGERATION EQUIPMENT BY VENDOR SHOWN FOR REFERENCE ONLY. 3/16" = 1'-0" 1 PLUMBING ROOF PLAN N.T.S. 2 FREEZELESS ROOF HYDRANT ROOF DRAIN CALCULATIONS 0.0104 = CONVERSION FACTOR - GPM/SQFT FOR 1"/HR RAINFALL. AREA NAME AREA (A1) PARAPET AREA 1/2 PARAPET WALL AREA (A2) RAIN FALL RATE (R IN INCHES) GPM=0.0104 x R x (A1+A2), [EQ 11-1 WPC 1106.2.1] 2021 WASHINGTON PLUMBING CODE: MINIMUM VERTICAL PRIMARY DRAIN SIZE PER TABLE 1106.3 LEFT SCUPPER 2599 ft² 342 ft² 171 ft² 1 29 2.5" RIGHT SCUPPER 2612 ft² 399 ft² 200 ft² 1 29 2.5" 5211 ft² 371 ft² OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST ~ ~~ A A B B 22 11 P201 P203 P001 P404 P403 P405 P405 P403 HD TYP 4 HD P204 P404 P204 P403 P403 P405 P403P404 P101 P404 P101 P101 P106 P106 P106 P106 P405 3" SS 3" SS 4" SS 4" SS 4" SS 4" SS 4" SS 3" SS 3" SS 4" SS SALES FLOOR 2 CASHIER SALES FLOOR 1 BACK ROOM WALK-IN COOLER COLD VAULT STORAGE ROOM WALK-IN FREEZER MEN'S RESTROOM WOMEN'S RESTROOM HALLWAY 1 2 3 4 5 65 7 P412 2" V P101P103 P103 TYP 3 P1.3 WCO P413 3" SS 8 P403 SALES FLOOR 3 FF = 353.50 FT YCO YCO YCO C001 TYP 3 B301 TYP 2 6" GW 9 WCO H201 4 6 B001 TYP 3 YCO YCO YCO YCO M10210 P101 P101 P403 WCO TYP 3 WCO C002 C004 C202C005 B003 TYP 2 PREP AREA 4" SS SEE CIVIL DRAWINGS FOR CONTINUATION (INV. 349.5 FT) 6" SS 4" SS 4" GW SEE CIVIL DRAWINGS FOR CONTINUATION (INV. 349.5 FT) 4" H.D. FLOOR SINK 4" H.D. 4" H.D. FINISH FLOOR 2% MIN. FLOOR SINK 4" H.D. FINISH FLOOR WALL 4" H.D. BEVERAGE COUNTER 4" H.D. BEVERAGE COUNTER FINISH FLOOR WALL WALL FOUNTAIN MACHINE COUNTER FINISH FLOOR 2% MIN. 2" 2" 3" 3" 3" 3" 2" 2" 2" 2" 2" 2" INSTALL HUB DRAIN 24" AFFINSTALL HUB DRAIN 24" AFF 4" AIR GAP4" AIR GAP 4" H.D. 2" FLOW FLOW COLD BEVERAGE STATIONFOUNTAIN MACHINE 4" H.D. 2" 4" H.D. 2" REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY P1.1.1 PROJECT NUMBER: 24212 PLUMBING FLOOR PLAN - WASTE AND VENT CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS 3/16" = 1'-0" 1 PLUMBING FLOOR PLAN - WASTE AND VENT KEYNOTES 1 PROVIDE 3-COMPARTMENT SINK DRAIN LINES WITH FLOW CONTROL DEVICE AND RUN TO FLOOR SINK. PROVIDE (3) 1 1/2" INDIRECT WASTE, 1 FOR EACH COMPARTMENT OF SINK. 2 CONTRACTOR TO COORDINATE UNDERGROUND SEWER PIPING WITH WALL FOOTING. 3 3" VTR. MAINTAIN 10'-0" FROM ALL OUTDOOR AIR INTAKES. 4 PROVIDE WALL CLEANOUT. REFER TO SHEET P1.2 5 AIR GAP TO BE TWICE THE EFFECTIVE OPENING OF THE INDIRECT WASTE PIPE. 6 REFER TO DETAIL 2/P1.1.1 FOR TYPICAL HUB DRAIN INSTALLATION. 7 2" VTR. MAINTAIN 10'-0" FROM ALL OUTDOOR AIR INTAKES. 8 ROUTE PIPING IN CHASE PROVIDED. 9 PROVIDE SAMPLING PORT WITH YCO AT GRADE PER AHJ. 10 WATER DISPENSER IS EQUIPPED WITH A PUMPED DRAIN. ROUTE 1/2" PUMPED DRAIN PIPING TO NEAREST FLOOR SINK AND DISCHARGE WITH AN AIR GAP. ROUTE PIPING CONCEALED IF ROUTED WITHIN CUSTOMER AREA. N.T.S. 2 HUB DRAIN DETAIL SLOPE MINIMUM 1/8" PER FOOT OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST A A B B 22 11 WALK-IN FREEZER STORAGE ROOM COLD VAULT WALK-IN COOLER SALES FLOOR 1 SALES FLOOR 2 HALLWAY MEN'S RESTROOM WOMEN'S RESTROOM BACK ROOM CASHIER 1 P204 1" HW 3/4" HWR 1" HW 1" CW 1" HW 3/4" HWR 3/4" CW 2" CW 1" HW 1" HW 1/2" CW 1" CW 3/4" HW P410 P410 3/4" CW 1/2" FDW 1/2" FW 2 B003 TYP 2 B301 TYP 2 C001 TYP 3 3 4 5P101 P101P101 P108 P108 P108 P108 P401 P201 P203 P001 P103 P103 P101 1 P1.3 4 P1.3 2 P1.3 3/4" HW 3/4" HW P413 1/2" CW 6 P402 B603 TYP 5 2" MAIN DOMESTIC WATER SERVICE FROM 2" METER AND REDUCED PRESSURE BACKFLOW PREVENTER. SEE CIVIL PLAN FOR CONTINUATION. 7 8 WHA H201 9 M102 B102 P101P101 TYP 2 P204 P414 C004 C005 C202 C002 B001 TYP 3 B101 TYP 2 1/2" FW 10FUTURE CONNECTION PREP AREA 11 SALES FLOOR 3 12 GENERAL NOTES IF POST MIX IS INSTALLED A STAINLESS R.P.B.A. MUST BE USED OR WILKINS 375X1 WITH NO COPPER INSTALLED DOWNSTREAM OF R.P.B.A. PLUMBING SYMBOLS WALL CLEANOUT HOSE BIBB FREEZE PROOF WALL HYDRANT YARD CLEANOUT FLOOR SINK ROOF DRAIN/OVERFLOW ROOF DRAIN FLOOR DRAIN T & P RELIEF VALVE WATER HAMMER ARRESTOR BACKFLOW PREVENTER SHUT-OFF VALVE IN VERTICAL LINE CHECK VALVE PLUG VALVE BALL VALVE TEE - TURNED UP TEE - TURNED DOWN ELBOW - TURNED UP ELBOW - TURNED DOWN COMPRESSED AIR NATURAL GAS DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN DOMESTIC COLD WATER OVERFLOW ROOF DRAIN LINE ROOF DRAIN LINE OIL WASTE GREASE WASTE SANITARY SEWER 110°F TEMPERED WATER WATER METER FILTERED WATER STORM SEWER IRRIGATION WATER THERMOSTATIC MIXING VALVE GAS COCK GAS PRESSURE REGULATOR PLUMBING VENT REVERSE OSMOSIS WATER CONDENSATE DRAIN CONNECT TO EXISTING EXISTING TO REMAIN PLUMBING VACUUM DEMO PIPE AREA OF SLAB CUT FLOW CONTROL VALVE THERMOMETER SS GW OW ST RD ORD IW T UNION FW G A CD RO V VAC M WHA TMV FD FS YCO FPWH HB WCO ETR RD VENT BELOW FLOORVBF FLOOR CLEANOUTFCO ?KEYNOTE CALLOUT SYMBOL (? = NUMBER) ?PLUMBING FIXTURE CALLOUT SYMBOL EF 1 MECHANICAL EQUIPMENT CALLOUT FOR PLUMBING REFERENCE LOCATION FILTERED + DESCALED WATERFDW REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY P1.1.2 PROJECT NUMBER: 24212 PLUMBING FLOOR PLAN-DOMESTIC WATER CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS 3/16" = 1'-0" 1 PLUMBING FLOOR PLAN HOT AND COLD WATER KEYNOTES 1 MAIN WATER SUPPLY LINE UP IN WALL TO ABOVE CEILING. COORDINATE EXACT LOCATION. 2 1-1/2" CW TO WATER FILTER (OR SIZE AS REQUIRED BY EQUIPMENT SUPPLIER). PROVIDE ACCESSIBLE BACKFLOW PREVENTER AS REQUIRED BY A.H.J. COORDINATE REQUIREMENTS WITH EQUIPMENT SUPPLIER. 3 SHUT-OFF (BALL VALVE) ABOVE CEILING. PROVIDE ACCESS (TYPICAL). 4 3/4" CW DOWN IN WALL/EXPOSED TO FREEZELESS HB. 5 CO2 LINE TO RUN UP WALL THEN OVERHEAD TO CONNECT TO CARBONATORS. INSTALL PER MANUFACTURERS' INSTALLATION INSTRUCTIONS. 6 ROUTE PIPING IN CHASE PROVIDED. 7 3/4" CW UP THROUGH ROOF TO FREEZELESS ROOF HYDRANT. 8 PROVIDE TRAP PRIMER FOR FLOOR DRAIN, CONNECT WITH NEAREST COLD WATER LINE. 9 FILTERED AND DESCALED WATER LINE ABOVE CEILING. 10 FILTERED WATER ABOVE CEILING. 11 HOSE BIBB ROUTED ABOVE CEILING AND DOWN INTERIOR WALL THEN TURN OUT. 12 PROVIDE NORMALLY CLOSED BYPASS LINE WITH VALVES. OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST P403 P403 P403 P403 P404 P404 P404 P403 P204 P204 P403 P403 P201 P203 P404 P101 P101 P106 P106 P106 P106 P101 P405 P405 1 1/2" V3" VTR 3" VTR 3" VTR P405 P405 3" SS 4" SS 4" SS 1 1/2" V 4" SS 4" SS 4" GW 4" GW 1 1/2" V 1 1/2" V 2" V 1 1/2" V P412 3" V H201 P103 P103 P101 2" V WCO 3" SS P413 3" SS P001 WCO 2" V YCO YCO2" V WCO M102 WCO YCO TYP 6 4" GW P101 P101 P204 P204 P201 P001 P203 P101 P101 P108 P108 P108 P108 P101 P410 P417 C001 TYP 3 B001 TYP 3 B003 TYP 2 B301 TYP 2 P401 P400 P410 1" HW 1" HW 1/2" CW 2" CW 2" CW 3/4" HWR 3/4" HW 1/2" CW 1" HW 2" CW 1" HW 1" CW 1" CW 1 1/2" CW 3/4" FDW H201 3/4" CW 3/4" CW P103 P103 3/4" CW END CAP FOR FUTURE CONNECTION TYP END CAP FOR FUTURE CONNECTION TYP 1/2" FW 1/2" FW 1/2" FDW P406 2" CW P413 1/2" CW P418 TYP P409 B101 TYP 2 B102 1/2" FDW 1/2" FDW P402 WHA P101 1" CW P418 TYP 2 1 P1.3 P101 P101 1" HW P414 1/2" FW M102 C004 C005 C202 C002 3/4" CW YELM, WA 48 PSI 110.9 (PREDOMINANTLY FLUSH VALVES) PER 2021 WPC 85.5 2" (VERIFY WITH WATER COMPANY) 48.0 PSI (PRESSURE IN MAIN) -8.3 PSI (LOSS THROUGH 2" METER) -2 PSI (LOSS THROUGH TAP) -25 PSI (FIXTURE LOSS AT END, FLUSH VALVE) -7 PSI (14 DROP FOR ELEVATION, 0.5 PSI LOSS PER FT) -12 PSI (BACKFLOW PREVENTER) 22.9 PSI (BOOSTER PUMP) 16.6 PSI (AVAILABLE PRESSURE) PIPE LENGTH (TAP TO METER) 38 FT PIPE LENGTH (METER TO BUILDING)196 FT PIPE LENGTH (BUILDING TO LAST FIXTURE)119 FT VERTICAL LENGTH 20 FT EQUIVALENT LENGTH OF FITTINGS 42 FT TOTAL DEVELOPED LENGTH 415 FT PRESSURE AVAILABLE 16.6 X 100 = 4.0 PSI/100 FT TOTAL LENGTH 415 SITE LOCATION: STATIC PRESSURE: TOTAL WATER SUPPLY FIXTURE UNIT: GPM: WATER MAIN: MAX ALLOWABLE LOSS (PER 100 FT OF PIPE): A PRESSURE TEST IS TO BE PERFORMED IMMEDIATELY AFTER AWARDING OF BID. IF PRESSURE IS LOWER THAN LISTED ABOVE, NOTIFY ENGINEER IMMEDIATELY. 1. PROVIDE IAPMO APPROVED BACKFLOW PREVENTER IN- LINE TO EACH "NON-CARBONATED" KITCHEN BEVERAGES EQUIPMENT. 2. PROVIDE IAPMO APPROVED REDUCED PRESSURE BACKFLOW PREVENTER TO EACH "CARBONATED" KITCHEN BEVERAGES EQUIPMENT (STAINLESS STEEL) 3. BEVERAGES LINES OF "CARBONATORS" SHALL NOT HAVE ANY COPPER LINES DOWNSTREAM OF REDUCED PRESSURE BACKFLOW PREVENTER. 4. BACKFLOW PREVENTERS SHALL HAVE PROPER DRAINS AND ACCESSIBLE FOR MAINTENANCE. NOTES: REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY P1.2 PROJECT NUMBER: 24212 PLUMBING RISERS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS N.T.S. 1 WASTE AND VENT PLUMBING RISER N.T.S. 2 HOT AND COLD WATER RISER GREASE INTERCEPTOR FIXTURES TAG DESCRIPTION DRAINAGE PER COUNT DRAINAGE TOTAL (DFU) P001 3-COMPARTMENT SINK W/ (2) 18" DRAIN BOARDS 3 1 3 P201 MOP SERVICE SINK 3 1 3 P203 WALL MOUNTED HAND SINK 2 1 2 P403 FLOOR SINK 0.5 1 0.5 P404 FLOOR DRAIN WITH TRAP PRIMER 0 1 0 Grand total 5 8.5 PLUMBING LOADS TAG DESCRIPTION CWFU HWFU DRAINAGE PER (DFU)COUNT CW TOTAL (CWFU) HW TOTAL (HWFU) DRAINAGE TOTAL (DFU) TOTAL WATER (WSFU) TOTAL WATER GPM P001 3-COMPARTMENT SINK W/ (2) 18" DRAIN BOARDS 3 3 3 1 3 3 3 6 3 P101 TOILET 10 0 10 6 60 0 60 60 30 P103 URINAL 10 0 4 2 20 0 8 20 10 P106 DROP-IN HAND SINK 0 0 3 4 0 0 12 0 0 P108 HAND SINK FAUCET - AUTOMATIC 2.25 2.25 0 4 9 9 0 18 9 P201 MOP SERVICE SINK 3 3 3 1 3 3 3 6 3 P203 WALL MOUNTED HAND SINK 2.25 2.25 2 1 2.25 2.25 2 4.5 2.25 P204 DROP-IN HAND SINK 2.25 2.25 3 2 4.5 4.5 6 9 4.5 P205 MANUAL SINK FAUCET 2.25 2.25 3 2 4.5 4.5 6 9 4.5 P402 WATER FILTER 1 0 0 0 0 0 P403 FLOOR SINK 0.5 7 0 0 3.5 0 0 P404 FLOOR DRAIN WITH TRAP PRIMER 0 0 0 4 0 0 0 0 0 P410 ENCASED NON-FREEZE HOSE BIB 1 0 0 2 2 0 0 2 1 P413 DRINKING FOUNTAIN 0.25 0 0.25 1 0.25 0 0.25 0.25 0.125 P417 FREEZELESS ROOF HYDRANT 1 0 0 1 1 0 0 1 0.5 Grand total 39 109.5 26.25 103.75 135.75 67.875 N.T.S. 3 WATER SUPPLY CALCULATION P001 HAS 2 MINUTE DRAIN TIME P403 ONLY RECIVES WASTE FROM P001 P404 IS EMERGENCY USE ONLY OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST - - - - - - - - - - - - - - - 85.5 1000 GAL GRAVITY GREASE INTERCEPTOR TO BE USED. 8.5 DFU'S REQUIRES A 750 MIN GAL GRAVITY GREASE INTERCEPTOR -WPC TABLE 1014.3.6 ~ ~ ~~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ UNION 1/2"CW TUBING SEAL WATERTIGHT 1/2"CW BELOW FLOOR STUD WALL 1/2"CW 1/2"CW TO TRAP, CONNECT AS REQ'D. FLOOR DRAIN FINISHED FLOOR STEEL ACCESS PANEL LAVATORY PROVIDE WITH TRAP COVER 18 " M I N . CONFIRM LOCATION OF DRAIN PIPE WHEN AT SIP WALL. B001 B001 B003 B003 B101 B102 C001 C001 C001 C004 C005 C002 P406 P406 H201 M102 WATER FILTER ITEM # 52 3/4" 3/4" 3/4" NO NC NO - NORMALLY OPEN NC - NORMALLY CLOSED NO ROUTE FW LINES IN CEILING SPACE OVER TO EQUIPMENT ROUTE FW LINES IN CEILING SPACE OVER TO EQUIPMENT FOUNTAIN OUTLET 3/4" FNPT FILTERED + DESCALED FILTERED ONLY TYP TYP B001 CARBONATOR INCLUDES BUILT-IN ASSE 1022 BACKFLOW PREVENTER NO B301 B301 B101 C202 BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD 6" PVC WASTE LINE WASTE LINE FINISHED GRADE 16"∅CONCRETE PAD TROWEL SMOOTH & EDGE WASTE LINE 3/4" T&P AND 1" DRAIN FROM DRAIN PAN TO MOP SINK 1-1/4" COLD WATER FEED W/ VACUUM RELIEF VALVE P400 INSTALL EWH IN GALV. PAN 24 GAGE & 1-1/2" MIN. RUN INDIRECT DRAIN TO MOP SINK ASME TEMPERATURE AND PRESSURE RELIEF VALVE. 3/4" RECIRC PUMP 1 1/4" INSTALL MINIMUM 1" INSULATION ON ALL HOT WATER PIPING AND THE FIRST 8' OF COLD WATER PIPING AT THE TANK. REFER TO DETAIL 1 ON A9.2. IN THE ARCHITECTURAL DWG. FOR WATER HEATER SHELF DETAIL. REFER TO 1/A9.2 FOR HOT WATER SUPPORT AND WALL CONSTRUCTION. CHECK VALVE TYP 140° F. 1 1/4" UNION TYP PROVIDE BALANCING VALVE SET TO 3 GPM A. SLOPE SANITARY PIPING 2 1/2" AND SMALLER AND ALL GREASE WASTE PIPING AT 1/4" PER FOOT FALL. SLOPE SANITARY SEWER PIPING 3" TO 6" AT 1/8" PER FOOT FALL. COORDINATE BUILDING SEWER LOCATION AND INVERT ELEVATION WITH CIVIL DRAWINGS. B. FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, FEES, PERMITS, CERTIFICATE OF INSPECTION, ETC. NECESSARY OR REASONABLE, REQUIRED FOR THE COMPLETE INSTALLATION OF ALL PLUMBING WORK. C. WORK SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL CODES, LAWS, ACTS, ORDINANCES, REGULATIONS AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. D. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL THE APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE, SAFETY, AND THE MANUFACTURERS STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. E. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL MAKE MODIFICATIONS INCLUDING OFFSETS, TURNS, AND RE-ROUTING REQUIRED TO COMPLETE THE INSTALLATION. DO NOT SCALE LOCATION OF EQUIPMENT OR PIPING. F. COORDINATE ALL PLUMBING WORK, INCLUDING EQUIPMENT AND PIPING, WITH OTHER TRADES PRIOR TO WORK. G. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING EQUIPMENT SO THAT NO INTERFERENCES ARE ENCOUNTERED WITH OTHER EQUIPMENT OR WITH STRUCTURAL ELEMENTS. H. ALL PLUMBING WORK IS TO RUN IN A NEAT AND PROFESSIONAL MANNER, WITH THE AESTHETICS OF THE FACILITY OF PARAMOUNT IMPORTANCE. ALL ROUGH-IN WORK TO BE HIDDEN WITHIN WALLS AND ABOVE CEILING UNLESS OTHERWISE NOTED. I. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES. CLOSELY COORDINATE ALL WORK WITH ALL OTHER TRADES. FAILURE OF THE CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES SHALL RELIEVE THE OWNER FROM ANY ADDED COSTS. J. THE CONTRACTOR SHALL DO ALL NECESSARY CUTTING OF WALLS AND CEILING. PATCH AROUND ALL OPENINGS TO MATCH EXISTING CONSTRUCTION. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT PERMISSION FROM THE ENGINEER. K. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE LOCATIONS OF FIXTURES, GENERAL NOTES REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY P1.3 PROJECT NUMBER: 24212 PLUMBING- SCHEDULES AND DETAILS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS P001 3-COMPARTMENT SINK W/ (2) 18" DRAIN BOARDS ADVANCE TABCO 9-3-54-18RL 0" 0" 0" 0" 1 GC TO SUPPLY AND INSTALL SINK P101 TOILET AMERICAN STANDARD 3043.001 1" 4" 6 VALVE, SLOAN 111 ESS-1.25-TMO-HW - WATER CONSERVATION 1.28 GALLONS PER FLUSH. OPEN FRONT SEAT - OLSONITE #10CC. P103 URINAL AMERICAN STANDARD 6590.001 3/4" 2" 2 URINAL FLUSH VALVE SLONE 186-ESS-0.5-TMO-HW AUTOMATIC HARD WIRED. WALL BRACKET SUPPORT SET AT ELEV. TO MEET ADA P106 DROP-IN HAND SINK ROYSTON INTEGRATED 3/8" 3/8" 0" 1 1/4" 4 SLOAN#SF2400. PROVIDE WITH F FLOW CONTROL. PROVIDE WITH TRAP COVER - TRUEBRO MODEL# 100 E-Z OR EQUAL CHROME STOPS 1/4 TURN, SUPPLIES INSUL SUPPLIES & TRAP PER ADA PROVIDE P408. P108 HAND SINK FAUCET - AUTOMATIC SLOAN SF-2400 3/8" 3/8" 0" 0" 4 HARDWIRED; FULL MODEL NUMBER SF-2400-4-PLG-TEE-CP-0.5GPM-MLM-IR-FCT PROVIDE P408. P201 MOP SERVICE SINK MUSTEE 63M 3/4" 3/4" 0" 3" 1 AMERICAN STANDARD #8344.111 WALL MOUNT FAUCET TOP BRACE, VACUUM BREAKER, STOPS P203 WALL MOUNTED HAND SINK ADVANCE TABCO 7-PS-60 1/2" 1/2" 0" 1 1/2" 1 PROVIDE P408. P204 DROP-IN HAND SINK ELKAY OR EQUAL K11515 3/8" 3/8" 0"2" 2 FAUCET BY G.C. CHROME STOPS 1/4 TURN SUPPLIES AND P-TRAP PROVIDE P408. P205 MANUAL SINK FAUCET CHICAGO FAUCETS 895-317CP 3/8" 3/8" 0" 2" 2 FOR USE WITH P204. P400 FIXED BLADDER TYPE EXPANSION TANK. AMTROL FLEXCON WATTS WILKINS ST-12 WH-18 PLT-12 XT-18 1 1/4" 0" 0" 0" 1 4.4 GALLON MINIMUM TOTAL CAPACITY, FACTORY STANDARD PRECHARGE CAPACITY. P401 ELECTRIC WATER HEATER A.O. SMITH DRE-52-24 1 1/4" 1 1/4" 1 3/4" P & T RELIEF VALVE. 52 GAL STORAGE. ELECTRICAL, 24 KW, 208V, 3PH. P402 WATER FILTER PENTAIR EVERPURE EV9437-10 3/4" 0" 0" 3/4" 1 3/4" NPT CONNECTION, PROVIDED BY FACILITIES P403 FLOOR SINK ZURN Z1901 7 1/2 GRATE WITH 12"X12" (6" DEEP) PORCELAIN SEDIMENT BUCKET P404 FLOOR DRAIN WITH TRAP PRIMER WADE 1000-S-TD6.1 4 SATIN STRAINER P405 FLOOR CLEANOUT J.R. SMITH 4100 SERIES 4 ADJUSTABLE FLOOR CLEANOUT, 5 IN ROUND NICKEL BRONZE TOP, 4 IN PIPE, GAS TIGHT GASKETED BRASS PLUG, NO HUB OUTLET, MD LOAD RATING. P406 DUAL CHECK VALVE ATMOSPHERIC PORT & STRAINER WATTS SD-3 3/8" 0" 0" 0" 15 STAINLESS STEEL BODY CONSTRUCTION WITH INTERNAL RUBBER COMPONENTS AND IS DESIGNED FOR CONTINUOUS OR INTERMITTENT PRESSURE APPLICATIONS. WITH A WYE PATTERN STRAINER. MAXIMUM WORKING PRESSURE: 150PSI (10 BAR) P408 LEAD-FREE THERMOSTATIC MIXING VALVE ZURN WILKINS ZW3870XLT 7 3/8" COMPRESSION CONNECTIONS, CHROME PLATED ASSE 1070 SET TO 110°F P409 RECIRCULATION PUMP TACO 003-BC4 3/4" 0" 0" 0" 1 HP: 1/40 - CONNECTION SIZES: 3/4” SWEAT P410 ENCASED NON-FREEZE HOSE BIB MIFAB MHY-20 3/4" 0" 0" 0" 2 ANTI-SIPHON VACUUM BREAKER PROTECTED. VANDAL RESISTANT VACUUM BREAKER. P412 1000 GALLON GREASE INTERCEPTOR. JENSEN PRECAST JP1000EE-G 1 OR EQUIVALENT MAKE/MODEL. INTERCEPTOR DESIGN AND INSTALLATION SHALL COMPLY WITH LOCAL AHJ REQUIREMENTS. PROVIDE SAMPLING PORT AS REQUIRED BY AHJ. PROVIDE WITH H20 TRAFFIC RATED INSTALLATION. P413 DRINKING FOUNTAIN OASIS PG8ACSLTM 3/8" 0" 1/2" 1 1/4"1 P414 WATER PRESSURE BOOSTER PUMP XYLEM 2AB310HME02 1 1/4" 0" 1 INTEGRATED VARIABLE SPEED CONSTANT PRESSURE SYSTEM. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 2HP VARIABLE SPEED CONTROLLER, PUMP, AND TANK INCLUDED. P417 FREEZELESS ROOF HYDRANT WOODFORD RHY2-MS 3/4" 0" 0" 0" 1 PROVIDE MOUNTING SYSTEM AND DRAIN. ROUTE 1/8" DRAIN LINE TO NEAREST APPROVED DRAIN WITH AIR GAP. HYDRANT TO BE PROVIDED WITH A DOUBLE CHECK BACKFLOW PREVENTER. P418 TRAP PRIMER SIOUX CHIEF SERIES 695 1/2" 0" 0" 0" 4 OR APPROVED EQUIVALENT. AMOUNTS AS REQUIRED PLUMBING FIXTURE SCHEDULE TAG DESCRIPTION MFG. MODEL ROUGH-IN SIZE COUNT TRIM/REMARKSCW HW FW SAN B001 FOUNTAIN DRINK DISPENSER CORNELIUS ED-300 0" 0" 1/2"3/4" 3 B003 ICED TEA BREWER WILBURT CURTIS RSTB 0" 0" 1/4" 0" 2 B101 ICE MAKER FOLLETT HCD1810RHT 0" 0" 3/8" 3/4" 2 19" FOLLETT REMOTE CHEWBLET B102 1 FOUNTAIN AND/OR BAGGER MANITOWOC IYF-1800C-161 0" 0" 3/8" 3/4" 1 30" MANITOWOC REMOTE ICE MAKER (1825LB) B301 FOUR BARREL COUNTERTOP FCB CORNELIUS VIPER ELITE-4B 0" 0" 1/2" 0" 2 B603 3 WIDE BIB RACK PACKAGE CORNELIUS 3BIFJ 0" 0" 0" 0" 5 C001 3-HOPPER BEAN TO CUP BREWER SCHAERER 040381-00058 EUS 0" 0" 3/8" 0" 3 C002 5-HD CAPPUCCINO WILBURT CURTIS PCGT5 0" 0" 1/4" 0" 1 C004 COLD DRAFT COFFEE DISPENSER BUNN NITRON COLD DRAFT C-TOP 4:1=12:1 WITH REMOVABLE DOOR GRAPHIC 0" 0" 3/8" 0" 1 C005 COLD BREW COFFEE DISPENSER BUNN NITRON COLD DRAFT ALL-NITRO W RDG & NGM 0" 0" 3/8" 0" 1 C202 ICE AND WATER DISPENSER FOLLETT 15CI100A-NW-NF-ST-00 - 15 SERIES CHEWBLET ICE MACHINE AND WATER DISPENSER 0" 0" 1/4" 0" 1 H201 ELECTRIC COMBI OVEN UNOX XAVC-0511-EPR 0" 0" 3/4" 1 1/4" 1 OVEN REQUIRES FILTERED AND DESCALED WATER. HD PVC HUB DRAIN --- ---7 SIZING PER P1.1.1 N.T.S. 1 TRAP PRIMER ASSEMBLY N.T.S. 2 EVERPURE WATER FILTER SYSTEM N.T.S. 3 2-WAY CLEANOUT DIAGRAM N.T.S. 4 WALL MOUNTED WATER HEATER M102 WATER DISPENSER GLACIER G21B 0" 0" 1/2" 0" 1 (1) 1/2" WATER LINE PER (3) MACHINES 15 PSI MINIMUM. EACH UNIT TO HAVE DEDICATED BALL VALVE SHUTOFF. INDIRECT DRAIN. OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST 1. ALL WORK TO BE DONE AND MATERIALS FURNISHED COMPLYING WITH APPLICABLE LAWS AND REGULATIONS, INCLUDING THE STATE OF WASHINGTON MECHANICAL, PLUMBING AND FIRE SAFETY CODES. OBTAIN AND PAY FOR REQUIRED PERMITS AND FEES. 2. ALL MATERIALS USED SHALL BE NEW AND UNDAMAGED. 3. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH CURRENT CONSTRUCTION INDUSTRY STANDARDS AND WORKMANSHIP. 4. FURNISH SHOP DRAWINGS TO ARCH/ENGINEER FOR APPROVAL PRIOR TO PLACING DELIVERY ORDERS. PROVIDE SHOP DRAWINGS OF ALL MANUFACTURED EQUIPMENT AND MATERIALS EXCEPT PIPE, PIPE FITTINGS AND GALVANIZED DUCTWORK. 5. FURNISH ACCESS DOORS (RATED OR NON-RATED AS REQUIRED) WHERE VALVES OR EQUIPMENT ARE CONCEALED BEHIND A NON ACCESSIBLE CEILING OR WALL. FURNISH ACCESS DOORS TO GENERAL CONTRACTOR FOR INSTALLATION. 6. FURNISH STEEL PIPE SLEEVES WHERE PIPES PENETRATE RATED WALLS. PROVIDE FIRESTOPPING MATERIALS AND SYSTEM TO MAINTAIN THE REQUIRED RATING OF THE WALL PENETRATED. PROVIDE SHOP DRAWINGS SHOWING LISTING AND RATING OF FIRESTOPPING MATERIALS. 7. ALL MANUFACTURED EQUIPMENT, ACCESSORIES AND MATERIALS SHALL BE USED AS INTENDED BY THE MANUFACTURER IN STRICT ACCORDANCE W ITH THE MANUFACTURER'S WRITTEN INSTALLATION, OPERATI0N AND MAINTENANCE INSTRUCTIONS. 8. CONTRACTOR SHALL PROVIDE IN ADDITION TO ANY OTHER WARRANTIES SPECIFIED, A ONE YEAR FULL LABOR AND MATERIAL WARRANTY ON ALL WORKMANSHIP, MATERIAL AND EQUIPMENT FURNISHED FOR THIS PROJECT. 9. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL OPENINGS AND REQUIRED LINTELS NEEDED FOR THE GENERAL CONTRACTOR FOR THE INSTALLATION OF MECHANICAL EQUIPMENT. 10. SAWCUTS, LINTELS, HEADERS, AND STRUCTURAL MODIFICATIONS TO THE BUILDING STRUCTURE NEEDED FOR THE INSTALLATION OF MECHANICAL EQUIPMENT SHALL BE APPROVED BY THE GENERAL CONTRACTOR, BEFORE INSTALLATION. 11. IN GENERAL, OPENINGS AND REQUIRED LINTELS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR PROVIDING DETAILS AND TEMPLATES OF ALL OPENINGS NECESSARY FOR MECHANICAL EQUIPMENT INSTALLATION INCLUDING: HOUSING, ACCESS DOORS, INSPECTION DOORS, AND PASSAGEWAYS FOR MECHANICAL EQUIPMENT. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR SEALING CRACKS AND FINISHING ROUGH EDGES LEFT FOLLOWING MECHANICAL INSTALLATION. 12. APPROVAL EQUALS: PLUMBING ITEMS MANUFACTURED BY A COMPANY OTHER THAN THAT WHICH WAS SPECIFIED IN THE SCHEDULE MAY BE SUBSTITUDED BY APPROVED SHOP DRAWINGS CONTIGENT UPON MEETING THE DESIGN, APPEARANCE, AND FUNCTIONAL STANDARDS ESTABLISHED BY THE ORIGINALLY SPECIFIED ITEM(S). THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS, CLEARANCES, ASSEMBLY, FIT, ETC. OF THE APPROVED EQUAL(S), AND THEIR AFFECT ON OTHER EQUIPMENT FIT AND OPERATION. THE CONTRACTOR IS LIABLE FOR ANY ADDED COSTS TO HIMSELF OR OTHERS CAUSED BY THE APPROVED EQUALS. PLUMBING SPECIFICATIONSSECTION 15010 BASIC MECHANICAL REQUIREMENTS 1. BALL VALVES SHALL BE CLASS 125 FOR WATER WITH ENDS AND MATERIALS TO MATCH PIPING SYSTEMS. 2. BALL VALVES 2" AND SMALLER SHALL HAVE BRONZE BODY, STAINLESS STEEL BALL, TEFLON SEATS, AND STUFFING BOX RING, LEVER HANDLE AND BALANCING STOPS, ENDS TO MATCH PIPING SYSTEM. PLUMBING SPECIFICATIONSSECTION 15100 VALVES 1. FURNISH PIPE AND DUCT HANGERS, WHERE REQUIRED, FIRMLY SUPPORTED FROM BUILDING STEEL, CONCRETE OR MASONRY STRUCTURE. SUPPORT PIPING SYSTEMES SECURELY WHILE ALLOWING FOR PIPE AND BUILDING EXPANSION AND CONTRACTION. PROVIDE COPPER PLATED HANGERS, FOR COPPER PIPE. USE ADJUSTABLE CLEVIS HANGERS OR ADJUSTABLE STEEL BAND HANGERS. MAXIMUM SPACING SHALL BE 5' FOR 1/2" PIPING, 7' FOR 3/4" TO 1/4" PIPING, 9' FOR 1-1/2" TO 2" PIPING. FURNISH PLUMBING EQUIPMENT SUPPORTS AS DETAILED OR AS REQUIRED TO SAFELY AND PERMANENTLY CARRY THE WEIGHT OF THE EQUIPMENT. 15140 SUPPORTS & ANCHORS 1. INSULATE ABOVE FLOOR WATER PIPING WITH ELASTOMERIC PLACTIC PERFORMED PIPE INSULATION WITHOUT JACKETING. ALL INSULATING MATERIALS TO HAVE FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPMENT RATING O F 50 OR LESS AS TESTED BY ANSI/ASTM E 84 (NFPA 233) METHOD. INSULATE ALL PIPING WITH SURFACE TEMPERATURES BELOW 75 DEGREE F WITH 1/2" INSULATION. INSULATE ALL PIPING WITH SURFACE TEMPERATURES 75 DEGREES F AND HIGHER WITH 1" THICK INSULATION. INSTALL MINIMUM 1" INSULATION ON ALL HOT WATER PIPING AND THE FIRST 8' OF COLD WATER PIPING AT THE TANK. JOINTS IN INSULATION SHALL BE GLUED, NOT TAPED. WHERE PIPES ARE EXPOSED AND LESS THAN 8' ABOVE FLOOR, PROVIDE HEAVY DUTY METAL JACKETING OVER INSULATION. INSULATE ABOVE FLO OR HORIZONTAL STORM PIPING WITH 1" FIBERGLASS PERFORMED PIPE INSULATION WITH FACTORY APPLIED ALL PURPOSE COVER. 15250 PLUMBING INSULATION 15411 WATER DISTRIBUTION 1. WITHIN BUILDING, SCHEDULE 40 PVC, DWV TYPE PIPE AND SOLVENT WELDED PIPE FITTINGS, SCHEDULE 30 PVC PIPE MAY BE USED FOR VENT PIPING WHERE PERMITTED BY CODE. HORIZONTAL PIPE SHALL BE SUPPORTED BY ADJUSTABLE RING HANGERS EQUAL TO ITT-GRINNEL FIG. 97. VERTICAL PIPING SHALL BE SUPPORTED AT EACH FLOOR OR ATTIC LEVEL BY RISER. INSTALL UNDERGROUND PVC PIPE ACCORDING TO ASTM D2321. 15420 DRAINAGE & VENT SYSTEMS 1. PROVIDE AIR CHAMBERS AT EACH FIXTURE CONNECTION. AIR CHAMBERS SHALL BE ONE SIZE LARGER THAN SUPPLY PIPE AND SHALL BE 12" LONG. WHERE REQUIRED BY PLUMBING CODE, FURNISH AND INSTALL MANUFACTURED WATER HAMMER ARRESTORS. 2. PLUMBING FIXTURES SHALL BE INSTALLED WHERE SHOWN ON THE ARCHITECTURAL DRAWINGS. INSTALL FIXTURES LEVEL AND PLUMB. FURNISH TRAPS WHERE REQUIRED. FIXTURES SHALL BE EASILY REMOVABLE FOR SERVICE AND CLEANING. 3. PROVIDE CHROME PLATED RIGID OR FLEXIBLE SUPPLIES TO FIXTURES WITH STOP VALVES, CHROME PLATED 17 GAUGE BRASS TRAPS WITH CHROME PLATED ESCUTCHEONS. 4. SEAL ALL FIXTURES TO WALL AND FLOOR USING SILICO NE SEALANT. MATCH SEALANT COLOR TO FIXTURE COLOR. 5. FIXTURES DESIGNATED BARRIER FREE SHALL BE INSTALLED IN COMPLIANCE WITH AMERICAN'S WITH DISABILITIES ACT. 6. ALL CLEANOUT COVERS TO BE STAINLESS STEEL. 15440 PLUMBING 1. ABOVE GRADE: WATER PIPING SHALL BE CROSSLINKED PE (PEX) TUBING: PEX TUBE SHALL BE TESTED AND CERTIFIED FOR POTABLE WATER SYSTEMS, AND SHALL COMPLY WITH ANSI/NSF STANDARD 14, ANSI/NSF STANDARD 61, AND ASTM F876 AND/OR ASTM F877. TUBE SHALL BE LABELED WITH THE ABOVE CERTIFICATIONS. PROVIDE PEX TUBING SYSTEM BY ONE OF THE FOLLOWING: UPONOR, OR APPROVED PEX ALTERNATIVE. FITTINGS AND CONNECTORS SHALL BE BY THE SAME MANUFACTURER AND ASSEMBLED WITH THE MANUFACTURER’S APPROVED TOOLS. THE SAME CO NNECTION METHOD SHALL BE USED THROUGHOUT THE INSTALLATION. a. AT CONTRACTOR’S OPTION, IN LIEU OF PEX PIPING SYSTEM AS SPECIFIED ABOVE TYPE L COPPER ASTM B 75, ASTM B 88, ASTM 251, ASTM B 447 WITH WROUGHT COPPER SOLDER-JOINT FITTINGS ASME B 16. 2. BELOW GRADE: WATER PIPING SHALL BE PEX PIPING SYSTEM IN COMPLIANCE WITH THE UPONOR PLUMBING DESIGN ASSISTANCE MANUAL (PDAM), CURRENT EDITION AND THE UPONOR PIPING SYSTEMS INSTALLATION GUIDE, CURRENT EDITION (OR APPROVED ALTERNATIVE). CROSSLINKED PE (PEX) TUBING, ASTM F876 WITHOUT JOINTS BENEATH THE SLAB. a. AT CONTRACTOR’S OPTION, IN LIEU OF PEX PIPING TYPE K COPPER WITH WROUGHT COPPER SOLDER-JOINT FITTINGS. SOLDER SHALL BE 9596-396 TIN-ANTIMONY ANSI/ASTM B 32 FOR HEATING SYSTEM PIPING. 3. THOROUGHLY FLUSH AND CLEAN ALL NEW AND EXISTING WATER PIPING SYSTEMS. TEST ALL PIPING SYSTEMS PER REGULATIONS IN ITEM NO.1 OR AT 225 PSI FOR A MINIMUM OF 2 HOURS WITH NO PRESSURE DROP INDICATED PRIOR TO INSULATING. 4. STERILIZE ALL DOMESTIC WATER PIPING PRE REQUIREMENTS OF LOCAL HEALTH DEPARTMENT. REVISION ISSUE DATE COPYRIGHT This drawings is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORE PROFESSIONAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY P1.4 PROJECT NUMBER: 24212 PLUMBING- SPECIFICATIONS CIRCLE K STORES, INC. 9548 KILLION RD SE, YELM, WA 98597 YELM, WA DBS JMS SAG JMS OTP 11/12/24 JOB NO.: SUITE 5274 479-636-5004 ROGERS, AR 72756 DESIGNED BY: DBS 1805 N 2ND ST