Loading...
Circle K - Yelm (Yelm & Killion), WA - Mechanical ReportAdministered by: ©2021 NEEA, All rights reserved Date: Nov 11, 2024 MECHANICAL COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R1, R2, and Group R3 & R4 over 3 stories Project & Applicant Informaon Project Title Cirkle K Yelm, WA - BG #33080 - 2021 WSEC For Building Department Use: Project Address 9548 Killion Rd SE Yelm, WA 98597 Applicant Name Sean Stanton Applicant Phone 479-636-5004 Applicant Email EnergyBG@teamofchoice.com Mechanical Compliance Summary Scope - Compliance verificaon provided in this report is limited to code minimum efficiency requirements for mechanical equipment types defined in Tables C403.3.2(1) through C403.3.2(16) of the 2021 WSEC-C. This includes efficiency mulpliers for economizer excepons. Performance criteria for addional energy efficiency and load management measures ARE NOT included in this report. Addional documentaon is required to demonstrate compliance with all other provisions of the energy code, including beer than code efficiency criteria for Secon C406. For quesons about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com. General Occupancy All Commercial General Building Use Type(s)Retail, Convenience Store Building Cond. Floor Area 5,192 General Project Types New Building New Building or Addion Mechanical Scope Single Zone Systems & Equipment Alteraon Mechanical Scope Project Cond. Floor Area 5,192 Floors Above Grade 1 Overall Compliance Path General Prescripve Mechanical Project Descripon Mechanical Compliance Scope and Method Project Type Mechanical Scope Economizer Excepon(s) Applied? DOAS Venlaon Provided? Equipment Efficiency Compliance Verificaon New Building Single Zone Systems & Equipment Yes Yes COMPLIES Addional Energy Efficiency Measures (AEM) No mechanical addional energy efficiency measures included in project Load Management Measures (LDM) No mechanical load management measures included in project Does building include occupancy classificaons requiring DOAS?Yes Does project include DOAS equipment?Yes Based on project scope do TSPR requirements apply?Yes Do all systems comply with Appendix D standard reference design or qualify for an excepon to TSPR?Yes Scope & Space Condioning NEW BUILDING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verificaon COMPLIES Single Zone Air Systems Category - Dedicated outside air system (DOAS) Air Systems Summary Informaon System/Equip ID Paired with other Systems/Equip Venlaon Airflow Control Venlaon Standard Venlaon CFM Venlaon energy recovery Energy Recovery Efficiency (%) OAU-1 Paired w/ one single zone system or equipment Constant volume IMC Venlaon 900 Yes per C403.3.5.1 DOAS ER 73.15 Air Systems & Equipment - Cooling System/ Equip ID Cooling System/Equip Type Specific Type Cooling Capacity (Btu/h) Econo Excepon Mulplier (Full) Required Cooling Efficiency (Code Min + Econo) Proposed Cooling Efficiency CE Units Efficiency Compliance Verificaon OAU-1 DX-DOAS, air cooled With energy recovery 29,000 0 5.2 6.1 ISMRE COMPLIES Air Systems & Equipment - Heang System /Equip ID Heang System/Equip Type Specific Type Heang Output Capacity Heat Pump Heang Capacity (Btu/h) Cooling Capacity (Btu/h) Required Heat Pump Heang Efficiency Proposed Heat Pump Heang Efficiency HPH Units Efficiency Compliance Verificaon 11/11/24, 4:19 PM Mechanical Compliance Summary https://waenergycodes.com/print_project_summary_form/mec?project_id=29899&form_version_id=24 1/2 (Btu/h)(Idencal to Cooling Table) OAU-1 DOAS Energy recovery venlator (ERV)0 0 0 COMPLIES Air Systems & Equipment Details System/Equip ID Discrete Area(s) Served Locaon In Project Documents - Plan/Detail #System/Equip Compliance Path OAU-1 1 M1.2.1 General Prescripve WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(12&13) DX-DOAS Units, With & Without ER Economizer Compliance Method: Air-side economizer provided Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, Room) Air Systems Summary Informaon System/Equip ID Quanty of Items Supply Airflow Control Venlaon Standard Venlaon CFM (Total if Mulple Items) Venlaon Air Source Paired with DOAS Venlaon energy recovery Energy Recovery Efficiency (%) RTU1 Constant volume IMC Venlaon 4000 Integral Air Systems & Equipment - Cooling System/ Equip ID Cooling System/Equip Type Specific Type Cooling Capacity per item (Btu/h) Econo Excepon Mulplier (Full) Required Cooling Efficiency (Code Min + Econo) Proposed Cooling Efficiency CE Units Efficiency Compliance Verificaon RTU1 Heat pump, terminal (PTHP)Packaged terminal HP, standard size 118,000 0 0 COMPLIES Air Systems & Equipment - Heang System /Equip ID Heang System/Equip Type Specific Type Heat Pump Heang Capacity per item (Btu/h) Cooling Capacity per Item (Btu/h) (Idencal to Cooling Table) Required Heat Pump Heang Efficiency Proposed Heat Pump Heang Efficiency HPH Units Efficiency Compliance Verificaon RTU1 Heat pump, terminal (PTHP), heang Packaged terminal HP, standard size 115,000 118,000 0 COMPLIES Air Systems & Equipment Details System/Equip ID Discrete Area(s) Served Locaon In Project Documents - Plan/Detail #System/Equip Compliance Path RTU1 1 M1.2.3 General Prescripve WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(4) Packaged Terminal, Vercal AC & HP and Room AC Units Economizer Compliance Method: Air-side economizer provided WSEC Equip Efficiency Reference Table - Heang: Table C403.3.2(4) Packaged Terminal, Vercal AC & HP and Room AC Units 11/11/24, 4:19 PM Mechanical Compliance Summary https://waenergycodes.com/print_project_summary_form/mec?project_id=29899&form_version_id=24 2/2