Circle K - Yelm (Yelm & Killion), WA - SIP OTPSCALE DATE ORDER NUMBER - POSITION REVISION NTS W-0.0 Ci r c l e K Y e l m W A 9 8 5 9 7 NW C Y e l m A v e . & K i l l i o n R o a d COVER PAGE DATE 11/12/2024 81280 - 000 DAG ... ... ... ... . . . . If checked above, fabrication may begin. The check does not authorize changes to the sales order unless stated separately. If checked above, fabrication will not begin. Please mark necessary corrections for resubmittal. Corrections made will be limited to items marked up. Reviewing of shop drawings is the responsibility of the customer. Once these drawings are approved, the measurements and dimensions become the responsibility of the customer/purchaser of the panels. By signing below, the customer acknowledges: 1) the correctness of the prints (including any redline changes) 2) these prints are ready to enter into production 3) the customer gives PorterCorp approval to produce the product according to these prints PorterCorp is not responsible if any issues arise that would have been prevented by the customers thorough panel review once the plans are signed by the customer and received by PorterCorp. As a supplier of SIP materials only, PorterCorp does not assume responsibility for errors in design, engineering or dimensions. Any subsequent alterations made after signing the documents that result in field modifications costs or field technician visit costs will be the responsibility of the customer. THIS ORDER USES THE FOLLOWING PANEL TYPES TOP SKIN: 7/16" OSB BOTTOM SKIN: 19/32" OSB OSB TREATMENTS: NONE TOP SKIN: 7/16" OSB BOTTOM SKIN: 7/16" OSB OSB TREATMENTS: NONE TOP SKIN: 7/16" OSB BOTTOM SKIN: 7/16" OSB OSB TREATMENTS: NONE SIP WALL PANEL: SIP ROOF PANEL: SIP FLOOR PANEL: THIS CHECKLIST IS PROVIDED TO ASSIST CUSTOMERS WITH THE REVIEW OF THE SIP PANEL LAYOUT DRAWINGS AGAINST THE INFORMATION PROVIDED ON FILE. THIS HELPS TO ENSURE THE QUALITY OF THE SIP PRODUCT AND EASE OF CONSTRUCTION IN THE FIELD. SIP DRAWING SET IS BASED OFF: 1) ARCHITECTURAL DWGS DATED: 2) STRUCTURAL DWGS DATED: 3) CAD DRAWINGS DATED: R-VALUE @ 75° F U-FACTOR @ 75° F R-VALUE @ 25° F U-FACTOR @ 25° F R-VALUE @ -25° F U-FACTOR @ -25° F 4-5/8" 6-5/8" 8-3/8" 10-3/8" 12-3/8" 3-3/4" CORE THICKNESS EPS TYPE 1 5-3/4" 7-1/2" 9-1/2" 11-1/2" 15.6 23.3 NOMINAL PANEL THICKNESS (7/16" OSB) 30.1 37.9 45.6 0.064 0.043 0.033 0.026 0.022 16.9 25.4 32.8 41.3 49.8 0.059 0.039 0.030 0.024 0.020 18.5 27.8 33.9 42.6 51.4 0.054 0.036 0.028 0.022 0.018 12 SIP PANEL ELEVATION MARKER SLOPE MARKER CONCRETE WINDOW / DOOR N 1 A-1.1 DETAIL CALLOUT A-1.1 1 SECTION MARKER 1 REVISION 1 HOLD DOWN X PLAN NORTH DESIGN CODE: 2021 WSBC SNOW LOAD: Pg = 18 PSF ROOF LOADS: LL = 20 PSF DL = PER PLAN WIND LOAD: Wind Speed: 97 MPH Wind Exposure: C SEISMIC DESIGN: Ss = 1.294 Si = 0.468 Design Category: D Site Class: D A.B. = ANCHOR BOLTS EXT. = EXTERIOR INT. = INTERIOR O.C. = ON CENTER R.O. = ROUGH OPENING SIM. = SIMILAR S.F.B.O. = STICK FRAMED BY OTHERS SJS = INSULATED HEADER TRIM. = TRIMMER TYP. = TYPICAL U.N.O. = UNLESS NOTED OTHERWISE TYPICAL PANEL NUMBERING SYSTEM: 100 SERIES = SIP WALL PANEL NUMBERS 400 SERIES = SIP FLOOR PANEL NUMBERS 600 SERIES = SIP ROOF PANEL NUMBERS W-0.0 COVER PAGE W-0.1 GENERAL NOTES W-0.2 GENERAL NOTES W-0.3 GENERAL NOTES W-1.0 FIRST FLOOR PLAN W-1.1 HOLD DOWN LOCATIONS W-2.0 NORTH / SOUTH ELEV. W-2.1 WEST / EAST ELEVATION W-2.2 WALL ELEVATIONS W-2.3 WALL ELEVATIONS W-2.4 WALL ELEVATIONS W-3.1 ROOF PANEL PLAN W-4.0 BUILDING SECTION W-4.1 BUILDING SECTION W-5.0 CONSTRUCTION DETAILS W-5.1 CONSTRUCTION DETAILS W-5.2 CONSTRUCTION DETAILS W-5.3 CONSTRUCTION DETAILS W-5.4 CONSTRUCTION DETAILS W-5.5 CONSTRUCTION DETAILS OUTSIDE SKIN: 7/16" OSB INSIDE SKIN: 7/16" OSB OSB TREATMENTS: NONE OUTSIDE SKIN: 7/16" OSB INSIDE SKIN: 7/16" OSB OSB TREATMENTS: NONE PERMIT SET NOTE: DUE TO SEISMIC CATEGORY D, CONSTRUCTION ADHESIVE IS NOT PERMITTED AT THE SIP PANEL JOINT CONNECTIONS. HOWEVER, CONSTRUCTION ADHESIVE IS ALLOWED WHEN JOINING MULTI-PLY LUMBER PIECES TOGETHER. STAPLES ARE NOT PERMITTED AT THE SIP PANEL JOINTS, ONLY SPECIFIED NAILS. 8 1 7 / 3 2 " " NONE 6 5 / 8 " 4 5 / 8 " NONE DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREI C H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 001 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION REVISION DATE NTS Ci r c l e K Y e l m W A GENERAL NOTES W-0.1 DAG ENGINEERING SEAL (IF REQ'D) DESIGN CRITERIA: BUILDING CODE: 2021 WASHINGTON STATE BUILDING CODE (BASED ON 2021 IBC) OCCUPANCY CATEGORY = II LIVE LOAD ROOF LIVE LOAD: 20 PSF GROUND SNOW LOAD (Pg): 18 PSF FLAT ROOF SNOW LOAD (Pf): 18 PSF SNOW EXPOSURE FACTOR (Ce): 1.0 SNOW LOAD IMPORTANCE FACTOR (I): 1.0 THERMAL FACTOR (Ct): 1.1 NOTE: ADDITIONAL LOADING DUE TO DRIFTING AT CHANGES IN ROOF ELEVATIONS AND ICE AT OVERHANGS PER APPLICABLE CODE. DEAD LOAD ROOF DEAD LOAD: PER FRAMING PLAN PSF WIND LOAD BASIC WIND SPEED (V): 97 MPH WIND IMPORTANCE FACTOR (I): 1.0 EXPOSURE CATEGORY: C SEISMIC LOAD DESIGN CATEGORY: D SITE CLASSIFICATION: D SEISMIC IMPORTANCE FACTOR (Ie): 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION Ss = 1.294 S1 = 0.468 SPECTRAL RESPONSE COEFFIENTS SDs = 0.863 SD1 = 0.571 NOTE: THE STRUCTURE IS DESIGNED FOR THE ABOVE LIVE LOADS IN ADDITION TO THE LATERAL LOADS, SUPERIMPOSED DEAD LOADS AND SELF-WEIGHT OF THE STRUCTURE. WHERE APPLICABLE, THE LIVER LOADS ARE REDUCED IN ACCORDANCE WITH THE PROVISIONS OF THE BUILDING CODE. THE SNOW LOADS ON LOWER ROOFS ADJACENT TO HIGH ROOFS OR SLOPED ROOFS ARE INCREASED FOR THE EFFECT OF DRIFTING. BUILDING IS NOT DESIGNED FOR FUTURE VERTICAL OR HORIZONTAL EXPANSION. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS . . . . PERMIT SET ... ... ... ... 1. POST INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. DO NOT USE IMPACT WRENCH TO SET OR TIGHTEN POST-INSTALLED ANCHORS. ALL POST-INSTALLED ANCHORS SHALL BE TORQUED TO MANUFACTURE'S REQUIREMENTS. ALL POST-INSTALLED ANCHORS SHALL REQUIRE CONTINUOUS SPECIAL INSPECTION PER LOCAL CODE. 2. ADHESIVE ANCHORS (CONCRETE): COMPLY WITH ICC AC 308, AND SHALL BE ONE OF THE FOLLOWING: 1. SIMPSON SET-XP (ICC-ES ESR-2508) 2. HILTI HIT-HY 200 (ICC-ES ESR-2322) OR APPROVED EQUAL 3. EXPANSION ANCHORS (CONCRETE): COMPLY WITH ICC AC 193, AND SHALL BE ONE OF THE FOLLOWING: 1. SIMPSON STRONG-BOLT WEDGE ANCHOR (ICC-ES ESR-1771) OR APPROVED EQUAL 4. SCREW ANCHORS (CONCRETE): COMPLY WITH ICC AC 193, AND SHALL BE ONE OF THE FOLLOWING: 1. SIMPSON TITEN HD (ICC-ES ESR-2713) OR APPROVED EQUAL. 5. MINIMUM EMBEDMENT OF BOLTS IN GROUT, OR CONCRETE: AS NOTED ON SIP DETAIL PAGE. 6. POST INSTALLED ANCHORS TO BE INSTALLED IN CONCRETE BASE MATERIAL SHALL HAVE CURRENT ICC APPROVAL FOR USE IN BOTH CRACKED AND UNCRACKED CONCRETE IN ACCORDANCE WITH ACI 355.2, ICC ES AC193, AND ICC ES AC308. POST-INSTALLED ANCHORS: POST INSTALLED ANCHORS (CONT.) 7. POST INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIED IN THE DRAWINGS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER OF RECORED PRIOR TO USING POST INSTALLED ANCHORS IN PLACE OF MISSING OR INCORRECTLY LOCATED CAST-IN-PLACE ANCHORS. CARE SHOULD BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REBAR. 8. POST INSTALLED ANCHORS IN CONCRETE OR CONCRETE MASONRY UNITS WHEN NOT EXPOSED TO EARTH, WEATHER, OR CORROSIVE ENVIRONMENT SHALL BE AS NOTED BELOW: - EXPANSION ANCHORS SHALL BE STUD TYPE WITH A STEEL EXPANSION SLEEVE (WEDGE) AND ZINC COATING IN ACCORDANCE WITH ASTM B633. - THREADED ANCHOR RODS FOR EPOXY ADHESIVE ANCHORS IN CONCRETE SHALL BE ASTM A193 GRADE B7, ASTM A36, ASTM F1554 GRADE 36 OR AS NOTED IN THE DRAWINGS. -POST INSTALLED ANCHORS IN CONCRETE OR CONCRETE MASONRY UNITS WHEN EXPOSED TO EARTH, WEATHER, OR CORROSIVE ENVIRONMENT SHALL BE MANUFACTURED FROM AISI 304/316 STAINLESS STEEL. -HOLES SHALL BE DRILLED WITH A BIT AND SHALL BE CLEAN & FREE OF DUST USING A METHOD THAT COMPLIES WITH ALL THE MANUFACTURER'S WRITTEN INSTRUCTIONS. DO NOT CUT OR DAMAGE REINFORCING STEEL OR TENDONS DURING DRILLNG OPERATIONS. WOOD CONSTRUCTION 1. STRUCTURAL SAWN LUMBER, GLUED LAMINATED TIMBER AND CONNECTIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 2018 NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. 2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH THE APA "1998 PLYWOOD DESIGN SPECIFICATION". 3. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5456 WITH THE FOLLOWING ALLOWABLE DESIGN STRESSES: MICROLAM LVL E = 1900 KSI Fb = 2600 PSI Fc(par) = 2310 PSI Fc(perp) = 750 PSI Fv = 285 PSI PARALLAM PSL E = 2000 KSI Fb = 2900 PSI Fc(par) = 2900 PSI Fc(perp) = 650 PSI Fv = 290 PSI TIMBER STRAND LSL E = 1500 KSI Fb = 2250 PSI Fc(par) = 1950 PSI Fc(perp) = 650 PSI Fv = 285 PSI 4. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO "VOLUNTARY PRODUCT STANDARD PS2- 10 PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL - SIP PANELS". 5. PREFABRICATED WOOD I-JOIST SHALL CONFORM TO ASTM D 5055 6. ROOF SHEATHING OVER WOOD FRAMING: USE 1/2" A.P.A. RATED PLYWOOD WITH EXTERIOR GLUE PS 1 OR A.P.A. RATED ORIENTED STRAND BOARD (O.S.B.) WITH EXTERIOR GLUE PS 2, 32/16 SPAN INDEX. PANEL EDGES SHALL BEAR ON THE FRAMING MEMBER AND BUTT ALONG THEIR CENTER LINE. STAGGER JOINTS. FASTEN SHEATHING WITH 8d COMMON, 0.131 x 2 1/2" FASTENER SPACINGS SHALL BE 6" O.C. AT DIAPHRAGM BOUNDARY NAILING AND AT SUPPORTED PANEL EDGES, AND 12" O.C. AT INTERMEDIATE SUPPORTS INCLUDING EACH OF ANY MULTIPLE MEMBERS. MINIMUM EDGE DISTANCE 3/8" WITH 1/8" GAP BETWEEN SHEETS. LAY UP SHEATHING WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. SHEATHING SHALL CONFORM TO ICC ESR-2586. 7. PROVIDE ONE LINE OF BRIDGING FOR EACH 8'-0" OF SPAN FOR ROOF JOISTS AND FLOOR JOISTS. THE BRIDGING SHALL CONSIST OF 1" BY 3" LUMBER, DOUBLE NAILED AT EACH END OR EQUIVALENT METAL BRACING OF EQUAL RIGIDITY OR FULL DEPTH SOLID BLOCKING. 8. JOIST SHALL BE SUPPORTED LATERALLY AT THE ENDS AND AT EACH SUPPORT BY SOLID BLOCKING NOT LESS THAN 2" IN THICKNESS AND THE FULL DEPTH OF THE JOIST. 9. HOLES BORED IN JOISTS SHALL NOT BE WITHIN 2" OF THE TOP OR BOTTOM OF THE JOIST AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED 1/3 THE DEPTH OF THE JOIST. BORING HOLES IN PRE-ENGINEERED JOIST ARE NOT ALLOWED WITHOUT APPROVAL FROM THE MANUFACTURER. 10. JOIST FRAMING FROM OPPOSITE SIDE OF A BEAM, GIRDER OR BEARING WALL SHALL BE LAPPED AT LEAST 3". 11. JOIST FRAMING INTO THE SIDE OF A WOOD GIRDER SHALL BE SUPPORTED BY FRAMING ANCHORS OR JOIST HANGERS. 12. ALL STRUCTURAL LUMBER FOR STUDS AND FRAMING LUMBER GRADE (MINIMUM): SPF NO.2 OR BETTER, UNLESS NOTED OTHERWISE. 13. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE TOP PLATES INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOISTS IN DOUBLE TOP PLATES SHALL BE OFFSET AT LEAST 48" AND SHALL BE NAILED WITH NOT LESS THAN (8) 16D FACE NAILS ON EACH SIDE OF THE JOINT. 14. BOLTS AND LAG SCREWS SHALL CONFORM TO ASTM A307. 15. NAILS, SPIKES AND STAPLES SHALL CONFORM TO ASTM F-1667. 16. THE NAILING SCHEDULE FOR WOOD FRAMING ELEMENTS SHALL COMPLY WITH THE BUILDING CODE OF RECORD. 17. LUMBER SHALL BE HANDLED AND COVERED AS TO PREVENT MARRING AND MOISTURE ABSORBTION FROM SNOW OR RAIN UNTIL THE BUILDING IS ENCLOSED. 18. ERECTION OF STRUCTURAL TIMBER FRAMING SHALL BE IN ACCORDANCE WITH AITC-105 AND THE CODE OF STANDARD PRACTICE AITC-106. 19. FABRICATED WOOD STRUCTURAL ELEMENTS AND ASSEMBLIES OF WOOD CONSTRUCTION, SUCH AS WOOD TRUSSES, SHALL BE BY AN APPROVED FABRICATOR OR MANUFACTURE. 20. FASTENERS, INCLUDING NUTS AND WASHERS, IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE OF HOT-DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. WOOD CONSTRUCTION (CONT.) DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 002 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION REVISION DATE NTS Ci r c l e K Y e l m W A GENERAL NOTES W-0.2 DAG . . . ENGINEERING SEAL (IF REQ'D) PREFABRICATED WOOD TRUSSES I. SUBMITTALS A. WOOD TRUSS SHOP DRAWINGS 1. TRUSS LAYOUT DEPICTING THE TRUSS ID AND LOCATION, SPACING, SPANS, GIRDER LOCATIONS, PIGGYBACK BASE AND CAP LOCATION AND REQUIRED HANGERS AND/OR CLIPS. EXACT PLACEMENT TO BE DETERMINED BY THE TRUSS MANUFACTURE. 2. TRUSS SHOP DRAWINGS AND CALCULATIONS SEALED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THE PROJECT. DESIGN LOADS LISTED SHALL BE BASED ON SITE SPECIFIC WIND AND GROUND SNOW LOADS AND MEET ALL STATE AND LOCAL BUILDING CODES. ALL BRACING REQUIREMENTS NOTED ON THE SHOP DRAWING. 3. SUBMIT SEALED SHOP DRAWINGS AND CALCULATIONS FOR REVIEW TO ARCHITECT / E.O.R./ SIP ENGINEER FOR THE ASSEMBLY OF PREFABRICATED, ENGINEERED WOOD TRUSSES AND TRUSS GIRDERS, TOGETHER WITH ALL BRACING, CONNECTIONS AND OTHER STRUCTURAL ELEMENTS. B. QUALITY ASSURANCE 1. ALL PREFRABICATED WOOD TRUSSES SHALL BE DESIGNED TO MEET THE JOB SITE LOADING REQUIREMENTS. FABRICATION AND ERECTION SHALL BE PER TRUSS PLATE INSTITUTE, AMERICAN FOREST PORDUCTS ASSOCIATION, WOOD TRUSS COUNCIL OF AMERICA AND NATIONAL DESIGN STANDARD SPECIFICATIONS. 2. WOOD TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURE. THE MANUFACTURE'S ENGINEER SHALL BE RESPONSIBLE FOR THE DESIGN ADEQUACY AND SAFETY OF ALL WOOD TRUSSES. 3. FOR TRUSSES BROKEN OR SPLIT WEBS / CHORDS, DAMAGED OR MISSING PLATES OR ANY FIELD MODIFICATIONS, THE FOLLOWING INFORMATION NEEDS TO BE RELAYED TO THE TRUSS MANUFACTURE'S ENGINEER: -TRUSS ID - LOCATION OF TRUSS ON LAYOUT - IS TRUSS INSTALLED OR ON GROUND - EXACT LOCATION AND DIMENSION OF BREAK OR DAMAGE - PHOTOGRAPH OF AREA IN QUESTION C. MATERIALS 1. TOP CHORDS, BOTTOM CHORDS AND WEBS CONSISTING OF MSR/MEL LUMBER TO MEET DESIGN REQUIREMENTS. LUMBER SHOULD BE FREE OF DEFECTS, SUCH AS KNOTS, WANE OR SPLITTING. 2. ATTACHMENTS OF CHORDS OR WEBS SHALL BE A GALVANIZED METAL PLATE IN ACCORDANCE TO ANSI / TPI 1 -20 1 4. PLATE SIZE AND PLACEMENT TO MATCH REQUIREMENTS NOTED ON TRUSS DRAWING. DAMAGED, MIS-ALLIGNED OR PULLED OUT PLATES MUST BE REVIEWED BY TRUSS MANUFACTURE'S ENGINEER. 3. CONNECTIONS OF WOOD TRUSSES SHALL BE MADE WITH APPROPRIATE TRUSS HANGERS SIZED BY TRUSS MANUFACTURE. HANGERS, CLIPS OR HOLD DOWNS MANUFACTURED BY SIMPSON STRONG-TIE COMPANY OR AN APPROVED ALTERNATIVE FOR LOADS SPECIFIED. D. HANDLING & INSTALLATION 1. INSPECT TRUSSES UPON ARRIVAL TO JOB SITE FOR CONFORMANCE WITH TRUSS DRAWINGS, DAMAGED OR MISSING PLATES, CRACKED OR BROKEN MEMBERS OR ANY OTHER DAMAGE. DO NOT CUT OR DRILL HOLES INTO ANY TRUSS MEMBER OR METAL CONNECTOR. 2. THE DESIGN AND ERECTION OF WOOD TRUSSES, INCLUDING PERMANENT BRACING AND TEMPORARY BRACING, SHALL CONFORM TO THE COMMENTARY AND RECOMMENDATIONS OF THE TRUSS PLATE INSTITUTE. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS . PERMIT SET ... ... ... ... SIP GENERAL / STANDARD NOTES: I . BEFORE ASSEMBLING THE PORTERSIP PACKAGE, PORTERCORP REQUIRES THE PANEL INSTALLER, GENERAL CONTRACTOR, PROJECT MANAGER, DEVELOPER AND ARCHITECT TO BE FAMILIAR WITH THE PORTERSIP INSTALLATION DRAWINGS. BY USE OF THESE SIP DRAWINGS AND DOCUMENTS, THE GENERAL CONTRACTOR, DEVELOPER AND PROJECT MANAGER CERTIFY THAT THEY HAVE STUDIED THESE SUBMITTAL DRAWINGS AND ACCEPT THE CONTENT. 2. PORTERCORP PUTS FORTH GREAT EFFORT TO PRODUCE THE MOST COMPLETE SET OF SUBMITTAL DRAWINGS POSSIBLE BASED ON THE MOST RECENT SET OF ARCHITECTURAL DRAWINGS PROVIDED. IT IS THE RESPONSIBILITY OF THE ARCHITECT TO CHECK AND VERIFY ALL DIMENSIONS, NOTES AND DETAILS ON THE PANEL DRAWINGS FOR CONFORMITY WITH THE CONSTRUCTION DOCUMENTS AND EXISTING CONDITIONS PRIOR TO BEGINNING THE PROJECT. 3. IT IS NOT PORTERCORP'S RESPONSIBILITY TO VERIFY CODE REQUIREMENTS. THIS RESPONSIBILITY WILL BE THE GENERAL CONTRACTOR, DEVELOPER AND PROJECT MANAGER. 4. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PROVIDE A LEVEL AND SQUARE FOUNDATION / SLAB TO SAFEGUARD A GOOD FIT OF THE PORTERSIP PRODUCT. PORTERCORP WILL NOT ASSUME RESPONSIBILITY FOR ANY VARIANCES FROM THE FINAL SIGNED PANEL DRAWINGS AND SPECIFICATIONS OR ADJUSTMENTS REQUIRED RESULTING FROM THE CONDITIONS REALIZED ON THE SITE, AND IT IS THE SOLITARY RESPONSIBILITY OF THE GENERAL CONTRACTOR. 5. ALL STATED DIMENSIONS DEMONSTRATED ON THESE DRAWINGS, SECTIONS AND DETAILS TAKE PRIORITY OVER SCALED DRAWINGS. 6. THE INSTALLER/GC SHALL ASSUME RESPONSIBILITY TO DETERMINE ALL MATERIALS REQUIRED FOR PROPER SIP PANEL INSTALLATION. THIS INCLUDES MATERIALS SUPPLIED BY PORTER AND ADDITIONAL MATERIALS REQUIRED TO COMPLETE THE SIP INSTALLATION. ALL LUMBER TO BE SPF #2 OR BETTER GRADE. 7. THE INSTALLER/GC IS RESPONSIBLE TO ENSURE PROPER SIP PANEL INSTALLATION WITH ADHESIVE AND FOAM FOLLOWING THE CONNECTION DETAILS PROVIDED. IT IS IMPORTANT TO AVOID ANY POTENTIAL AIR LEAKS OR CONDENSATION ISSUES. 8. FOR SIP ROOFS, INSTALL A VAPOR-PERMEABLE ROOF MEMBRANE AFTER ALLOWING ROOF TO DRY IF THE ROOF BECOMES WET. APPLY SIP TAPE AT THE PANEL JOINTS ON THE "WARM" SIDE OF THE ROOF. IN MOST COLD CLIMATES, TAPE SHOULD BE PLACED ON THE INTERIOR SIDE OF PANELS. IN HOT AND HUMID CLIMATES, SUCH AS GULF COAST AND FLORIDA, THE TAPE SHOULD BE PLACED ON THE EXTERIOR OF PANELS. 9. AN AIR TIGHT BUILDING IS CREATED WHEN A SIP BUILDING IS PROPERLY SEALED. IT IS THE GC'S RESPONSIBILITY TO ENSURE THE VENTILATION OF THE BUILDING WILL MEET PROPER HUMIDITY LEVELS AND AIR QUALITY. 1 0. THE INSTALLER/GC MAY EXPERIENCE GROWTH IN PANELS AT PANEL JOINTS DUE TO VARIABLES SUCH AS LUMBER THICKNESS, SIP PANEL SWELLING, FABRICATION TOLERANCES, ETC. FIELD CUTTING THE SIP PANEL MAY BE REQUIRED TO MAINTAIN THE DIMENSION ON THE PLANS. ADVICE CAN BE GIVEN ON THIS ISSUE BY CONTACTING OUR QUALITY CONTROL DEPARTMENT. SIP GUIDELINES: SIP DELIVERY / STORAGE COORDINATION OF TRADES: AFTER THE SIP STRUCTURE HAS BEEN ASSEMBLED, ANY ALTERATIONS, CUTS, PENETRATIONS, DAMAGE, ETC. OF THE INTERIOR AND/OR EXTERIOR OSB SKINS OF THE SIP PANELS ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. IF FOR ANY REASON, FIELD MODIFICATIONS OF THE SIP PANELS ARE REQUIRED, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND PROJECT MANAGER TO NOTIFY PORTERCORP, PRIOR TO FIELD MODIFICATION, FOR APPROVAL. SIP PANELS ARE OFTEN DELIVERED VIA TRACTOR AND FULL-LENGTH TRUCK. DUE TO THE SIZE AND WEIGHT OF THE TRUCK, AN IMPROVED ROADWAY SURFACE WITH SUFFICIENT CLEARANCE (APPROX. 13') IS REQUIRED. THE OFF-LOADING OF PANELS IS THE RESPONSIBILITY OF THE INSTALLER / GC. LARGE CAPACITY FORKLIFT WITH MINIMUM 5' FORKS OR FORK EXTENSIONS IS RECOMMENDED. IN ORDER TO REDUCE FREIGHT COSTS AND REDUCE THE NUMBER OF TRUCKS REQUIRED, SIP PANELS ARE NOT SHIPPED IN NUMERICAL SEQUENCE. FOR ORDERS OF 3 TRUCKS OR LARGER, COLOR CODES WILL BE USED TO GROUP THE PANELS BY AREAS OF THE BUILDING AND THESE COLOR GROUPS WILL BE SHIPPED TOGETHER. PANELS WILL BE DELIVERED WRAPPED IN HEAT SHRINK PLASTIC. IF FOR ANY REASON THE PANELS ARE NOT WRAPPED WHEN ARRIVAL, TARP THEM TO PROTECT FROM THE ELEMENTS AND USE SUPPORTS APPOXIMATELY EVERY 8' MAXIMUM TO KEEP PANELS ELEVATED AND UNIFORM ON LEVEL GROUND. EXTENDED STORAGE FOR MORE THAN 60 DAYS MAY CREATE PROBLEMS WITH THE SIP PANELS, SUCH AS EDGE SWELLING OR MOLD AND MILDEW OF WHICH PORTER WILL NOT ASSUME RESPONSIBILITY FOR. 1. ALWAYS HANDLE SIPS WITH CARE. DO NOT LIFT PANELS BY TOP SKIN OR DROP ON CORNERS. 2. USE MANUFACTURE CONSTRUCTION SEALANT ON ALL WOOD TO WOOD CONNECTIONS. USE MANUFACTURE FOAM SEALANT ON WOOD TO EPS AND EPS TO EPS CONNECTIONS. FILL ALL VOIDS WITH EXPANDING FOAM. 3. SIP WALL PANELS CANNOT BEAR DIRECTLY ON CONCRETE. TREATED LUMBER WITH SILL SEAL REQUIRED UNDER SIP OSB SKINS. TREATED PLATE TO BE RIPPED TO WIDTH OF SIP WALL PANELS. CLEAN DEBRIS FROM SILL PLATE BEFORE INSTALLING SIP PANELS. 4. PROVIDE LEVEL AND SQUARE FOUNDATIONS OR FLOOR DECKS TO SUPPORT SIP WALLS. TOLERANCES SHOULD BE 1/4" OR LESS IN 40'-0". 5. DO NOT INSTALL RECESSED CAN LIGHTING INTO SIP PANELS, AS THE HEAT CAN DAMAGE THE EPS FOAM CORE. 6. DO NOT CUT OSB SKINS FOR ELECTRICAL WIRE CHASES, USE FACTORY PROVIDED WIRE CHASES (1" DIAMETER). PLUMBING IS NOT ALLOWED INSIDE SIP PANELS. 7. USE TRUFAST SIP FASTENERS TO SECURE SIP PANELS. DO NOT OVER TIGHTEN SCREWS, WASHERS ARE RECOMMENDED TO PREVENT OVERTIGHTENING. USE SIPTP SCREWS FOR SIP TO WOOD CONNECTIONS, SIPLD SCREWS FOR SIP TO 18 GA THRU 22 GA METAL CONNECTIONS AND SIPHD SCREWS FOR SIP TO 16 GA THRU 1/4" STEEL. PROPER DRILL RPM MUST BE MAINTAINED FOR SIPHD SCREWS TO PREVENT DRILL TIP BURN OUT. 8. LUMBER GRADE USED IN SIP PANELS TO BE MINIMUM #2 SPF OR BETTER, KILN DRIED. 9. 12-3/8" SIP PANEL WEIGHS 3.8 PSF, 10-3/8" SIP PANEL WEIGHS 3.6 PSF, 8-3/8" SIP PANEL WEIGHS 3.5 PSF, 6-5/8" SIP PANEL WEIGHS 3.3 PSF & 4-5/8" SIP PANEL WEIGHS 3.2 PSF (DOES NOT INCLUDE ANY LUMBER OR SPLINES INSTALLED IN PANEL). 1 0. MECHANICAL VENTILATION IS RECOMMENDED, SUCH AS HRV OR ERV. CONSULT AN HVAC CONTRACTOR TO PROPER SIZE MECHANICAL SYSTEMS. 1 1. ALL NAILS SUPPLIED BY CONTRACTED INSTALLER. 1 2. PROTECT SIP PANELS FROM THE ELEMENTS AFTER INSTALLATION. DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 0025 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION REVISION DATE NTS Ci r c l e K Y e l m W A GENERAL NOTES W-0.3 DAG . . . ENGINEERING SEAL (IF REQ'D)CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS . PERMIT SET ... ... ... ... 2015 & 2018 IBC 2021 IBC INSPECTION CONDITION SPECIAL INSPECTION DESCRIPTION 1705.1.1 1705.1.1 ALL ALL DRILLED AND EPOXIED ANCHOR BOLTS 1705.3, TABLE 1705.3, TYPE 3 1705.3, TABLE 1705.3, TYPE 3 1705.3, TABLE 1705.3, TYPE 12 1705.3, TABLE 1705.3, TYPE 12 ALL ALL 1705.11.1 1705.12.1 IN WIND EXPOSURE CATEGORY B, WHERE V ult IS 154 MPH OR GREATER. IN WIND EXPOSURE CATEGORY C OR D, WHERE V ult IS 141 MPH OR GREATER. ALL ANCHORS CAST IN CONCRETE INSPECT FORM WORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE BEING FORMED. WHERE THE FASTENER SPACING AT PANEL EDGES IS 4 INCHES OR LESS, INSPECT NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF ELEMENTS OF THE SEISMIC FORCE-RESISTING SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, SHEAR PANELS AND HOLD DOWNS. SPECIAL INSPECTIONS: 1. PROVIDE SPECIAL INSPECTIONS IN ACCORDANCE WITH CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE FOR THE ITEMS SHOWN BELOW. 2. SPECIAL INSPECTORS SHALL PROVIDE WRITTEN DOCUMENTATION TO THE BUILDING OFFICIAL DEMONSTRATING THE COMPETENCE AND RELEVANT EXPERIENCE OR TRAINING OF THE SPECIAL INSPECTORS WHO WILL PERFORM THE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION. EXPERIENCE OR TRAINING SHALL BE CONSIDERED RELEVANT WHERE THE DOCUMENTED EXPERIENCE OR TRAINING IS RELATED IN COMPLEXITY TO THE SAME TYPE OF SPECIAL INSPECTION OR TESTING ACTIVITIES FOR PROJECTS OF SIMILAR COMPLEXITY AND MATERIAL QUALITIES. 3. SPECIAL INSPECTORS SHALL KEEP RECORDS OF SPECIAL INSPECTIONS AND TESTS. THE SPECIAL INSPECTORS SHALL SUBMIT REPORTS OF SPECIAL INSPECTIONS AND TESTS TO THE BUILDING OFFICIAL, AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT WORK INSPECTED OR TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF IT IS NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL, AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PRIOR TO THE COMPLETION OF THAT PHASE OF THE WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND TESTS, AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS OR TESTS, SHALL BE SUBMITTED AT A POINT IN TIME AGREED UPON, PRIOR TO THE START OF WORK BY THE OWNER OR OWNER’S REPRESENTATIVE TO THE BUILDING OFFICIAL PRIOR TO THE ISSUANCE OF CERTIFICATE OF OCCUPANCY. 4. ITEMS REQUIRING PERIODIC SPECIAL INSPECTIONS PER CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE FOR THIS SIP BUILDING CONSTRUCTION ARE AS FOLLOWS: DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 003 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION WALL PLAN REVISION DATE W-1.0 3/16" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) 1 SCALE: 3/16" = 1'-0" WALL PLAN 113'-0" 46 ' - 0 " 113'-0" 46 ' - 0 " 16 ' - 0 " 17'-6"12'-8"4'-0"15'-10"4'-2"15'-10"4'-0"16'-10"22'-2" 1' - 6 " 1' - 6 " 1' - 6 " 1' - 6 " 122'-0 1/16"¯ 120'-6 13/16"¯ W-5.0 3 W-5.0 1 W-5.0 3 W-5.0 2 PRE-FABRICATED WOOD TRUSSES AT 32" O.C. MAX. SPACING WALL 1 WALL 3 WA L L 2 WA L L 4 WA L L 5 WALL 6 WA L L 7 WA L L 8 WALL 9 WA L L 1 0 WALL 11 (UPPER)WALL 12 (UPPER) WALL 13 (UPPER)WALL 14 (UPPER) WALL 15 (UPPER) WA L L 1 6 ( U P P E R ) 4'-1"4'-1" NOTE: ALL EMBEDDED ANCHORS INSTALLED AND PROVIDED BY OTHERS. PLACE EMBEDDED ANCHORS WITHINT 8" OF DOOR OPENINGS. ASSUME 16'-0" SILL PLATE WHEN LOCATIONS ANCHORS. PROVIDE ANCHORS @ 12" FROM END OF BREAK BETWEEN 16' PLATES AND 8" FROM END OF WALL. = HDU14-SDS2.5 SIMPSON HOLD DOWN ANCHOR LOCATION - SEE DETAIL 16/W5.2 BY PORTER. W-5.3 26 W-5.2 18 NOTE: 1" DIAMETER ANCHOR ROD SUPPLIED AND INSTALLED BY OTHERS, EMBED PER STRUCTURAL DRAWINGS WALL 50 (B.O.)WALL 51 (B.O.) WA L L 5 2 ( B . O . ) WA L L 5 3 ( B . O . ) WA L L 5 4 ( B . O . ) WA L L 5 5 ( B . O . ) 7'-10 1/8"31'-9 5/8"43'-7 3/4"22'-11 5/8"7'-10 1/8" LEGEND = 2x6 FRAMING AND 7/16" OSB SHEATHING. SEE DETAIL 26 / W-5.3 WALL 57 (B.O.)WALL 58 (B.O.)WALL 59 (B.O.)W-5.0 1 W-5.4 33 NOTE: SEE SHEAR WALL SCHEDULE SHEET W-1.1 FOR SHEAR WALL DETAILS = STHD14 SIMPSON HOLDDOWN ANCHOR LOCATION (BY OTHERS) - SEE DETAIL 1/W-5.0 & 2/W-5.0 46'-5 13/16"+ WA L L 1 7 ( U P P E R ) = 2x6 FRAMING AND 7/16" OSB SHEATHING. SEE DETAIL 32 / W-5.4 = 2x6 FRAMING AND 7/16" OSB SHEATHING. SEE DETAIL 33 / W-5.4 W-5.4 32 WA L L 1 8 ( U P P E R ) WA L L 1 9 ( U P P E R ) WA L L 2 1 ( U P P E R ) WA L L 2 2 ( U P P E R ) WA L L 2 3 ( U P P E R ) WA L L 2 4 ( U P P E R ) WA L L 2 5 ( U P P E R ) WA L L 2 0 ( U P P E R ) WA L L 2 6 ( U P P E R ) W-5.1 8 39'-1 1/8"43'-7 3/4"30'-3 1/8" 12 ' - 7 3 / 4 " 5' - 4 1 / 2 " 27 ' - 1 1 3 / 4 " W-5.2 17 LOWER WALLS UPPER WALLS BU M P O U T D I M E N S I O N S BU M P O U T D I M E N S I O N S BUMP OUT DIMENSIONS 2'-10 3/4" 3'-4 1/2" 39'-8 3/4" W-5.1 8 LADDER WALL 56 (B.O.) 8'-2 5/8"31'-8"5'-9"22'-10"5'-9"31'-8"8'-2 5/8" 7'-8"4'-0"9'-2"7'-10"55'-8"7'-10"13'-2"7'-8" 6 5/8" 7'-8" 28'-4 1/4" 1'-6" 5'-8 1/2" 2'-9 1/4" 6 5/8" 6 5 / 8 " 7' - 8 " 30 ' - 8 " 7' - 8 " 6 5 / 8 " W-5.5 35 WALL 60 WALL 61 6'-8 7/8"6'-8 7/8" NOTE: DUE TO SEISMIC CATEGORY D, CONSTRUCTION ADHESIVE IS NOT PERMITTED AT THE SIP PANEL JOINT CONNECTIONS. HOWEVER, CONSTRUCTION ADHESIVE IS ALLOWED WHEN JOINING MULTI-PLY LUMBER PIECES TOGETHER. STAPLES ARE NOT PERMITTED AT THE SIP PANEL JOINTS, ONLY SPECIFIED NAILS. 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 0031 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION HOLD DOWN PLAN REVISION DATE W-1.1 3/16" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET NOTE: ALL EMBEDDED ANCHORS INSTALLED AND PROVIDED BY OTHERS. PLACE EMBEDDED ANCHORS WITHINT 8" OF DOOR OPENINGS. ASSUME 16'-0" SILL PLATE WHEN LOCATIONS ANCHORS. PROVIDE ANCHORS @ 12" FROM END OF BREAK BETWEEN 16' PLATES AND 8" FROM END OF WALL. NOT REQUIRED CHORDNAILING SHEAR WALL SCHEDULE PANEL DESIGNATION SW2 SHEATHING HOLD DOWN (1) 2X6 #2 SPF TREATED PLATE ATTACHMENT SW1 6-5/8" SIP .131" x 2-1/2" NAIL AT 4" O.C. AT EDGE AND INTERIOR 6x6 #1 SYP MINIMUM6-5/8" SIP AT EDGE AND INTERIOR SIMPSON STHD14 STRAP .131" x 2-1/2" NAIL AT 4" O.C. (2) 2x6 #2 SPF MIN. (INTERIOR PANEL EDGE) SW3 ENGINEERING SEAL (IF REQ'D) HOLD DOWN PLAN 1 SCALE: 3/16" = 1'-0" (2 ) J - B O L T T= 0.865 KIP WALL 9 113'-0" 1' - 6 " 113'-0" (INCLUDE UNDER WINDOW)(2) J-BOLTS 46 ' - 0 " 7 1 / 1 6 " WALL 6T= 5.021 KIP 120'-6 13/16"¯ WA L L 4 2'-10 3/4" 3'-4 1/2" 122'-0 1/16"¯ (INCLUDE UNDER WINDOW) 46 ' - 0 " 1' - 6 " WALL 1 WALL 3 WA L L 2 T=2.738 KIP T = 5.021 KIP T=2.898 KIP T= 4.945 KIPWA L L 7 (INCLUDE UNDER WINDOW) 7'-3 1/2"4'-1"90'-3"4'-1"7'-3 1/2" WA L L 5 WA L L 8 WA L L 1 0 7 1 / 1 6 " 7 1 / 1 6 " (2 ) J - B O L T (2 ) J - B O L T (2 ) J - B O L T (2) J-BOLTS LADDER (INCLUDE UNDER WINDOW) 1 W-5.0 1 W-5.0 W-5.0 1 W-5.0 1 31 W-5.4 30 W-5.4 30 W-5.4 NOTE: 1" DIAMETER ANCHOR ROD SUPPLIED AND INSTALLED BY OTHERS. REFER TO STRUCTURAL DRAWINGS FOR EMBEDMENT DEPTH = STHD14 SIMPSON HOLDDOWN ANCHOR LOCATION (BY OTHERS) - SEE DETAIL 1/W-5.0 & 2/W-5.0 = HDU14-SDS2.5 SIMPSON HOLD DOWN ANCHOR LOCATION - SEE DETAIL 16/W5.2 BY PORTER. CENTERLINE DIMENSION TO STHD14 STRAP CENTERLINE DIMENSION TO STHD14 STRAP 6-5/8" SIP .131" x 2-1/2" NAIL AT 4" O.C. AT EDGE AND INTERIOR SIMPSON HDU14-SDS2.5 w/ 1" ANCHOR (B.O.) 12 ' - 7 3 / 4 " 5' - 4 1 / 2 " NOTE: BUMPOUT 5/8" J-BOLT ANCHORS AT 48" ON CENTER 6 5 / 8 " 7' - 8 " 30 ' - 8 " 7' - 8 " 6 5 / 8 " 8'-2 5/8"31'-8"5'-9"22'-10"5'-9"31'-8"8'-2 5/8" 6 5/8" 2'-9 1/4" 5'-8 1/2" 1'-6" 28'-4 1/4" 7'-8" 6 5/8" T= 4.945 KIP 7' - 1 5 / 1 6 " C/ L L O C A T I O N O F R O D 22'-0 1/2"17'-4 1/2" 5/8" ANCHOR @ 24" O.C. w/ 3"x4-1/2" WASHERS - 3 GAGE MINIMUM 5/8" ANCHOR @ 24" O.C. w/ 3"x4-1/2" WASHERS - 3 GAGE MINIMUM 5/8" ANCHOR @ 24" O.C. w/ 3"x4-1/2" WASHERS - 3 GAGE MINIMUM 3 5/16" 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" 7- 1 / 1 6 " 3 5/16" HDU14-SDS2.5 1" ANCHOR ROD LOCATION - SEE DETAIL 16 / W-5.2 LOCATED AT GRID LINE 1/A & 1/B AND GRID LINE 2/A STHD14 SIMPSON HOLD DOWN LOCATED AT GRID LINE 2/B OF FOUNDATION & AT MIDDLE OF WALL 1 FRONT/BACK WALL SI D E W A L L 3 5/16" B 2 DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 004 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION ELEVATIONS REVISION DATE W-2.0 1/4" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) 1 FRONT SOUTH ELEVATION 2 REAR NORTH ELEVATION ELEV. 12'-2" ELEV. 10-6" ELEV. 3'-1 3/4" ELEV. 0'-0" T.O. WINDOW T.O. SILL ELEV. 0'-0" ELEV. 16'-4" T.O. SIP ROOF ELEV. 23'-0" ELEV. 21'-6" T.O. TOWER / PARAPET T.O. TOWER B.O. TRUSS ELEV. 21'-6" T.O. TOWER T.O. PARAPET ELEV. 18'-6" ELEV. 18'-6" T.O. PARAPET 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 005 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION ELEVATIONS REVISION DATE W-2.1 01/10/2024 Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) 3 EAST SIDE ELEVATION 4 WEST SIDE ELEVATION ELEV. 7'-2 3/8" ELEV. 0'-0" ELEV. 8'-2 3/8" ELEV. 0'-0" T.O. DOOR T.O. DOOR T.O. TOWER ELEV. 21'-6" ELEV. 21'-6" T.O. TOWER T.O. BUMP OUT DOOR ELEV. 9'-5" T.O. PARAPET ELEV. 18'-6" T.O. PARAPET ELEV. 18'-6" 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 006 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION ELEVATIONS REVISION DATE W-2.2 1/4" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) WA L L 2 WA L L 4 PRE-FABRICATED WOOD TRUSSES AT 32" O.C. 6-5/8" SIP INFILL PANELS BETWEEN TRUSSES - (42) 6-5/8" SIP PANELS PROVIDED AT 2'-6 1/2" WIDE. TRIM TO FIT SMALLER TRUSS SPACING (REFER TO DETAIL 7 / W-5.0) 113'-0" 3-PLY 18-7/8" LVL BEAM 3-PLY 18-7/8" LVL BEAM 3-PLY 18-7/8" LVL BEAM 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S W-5.4 28 W-5.0 1 W-5.0 7 1-1/8" DOUBLE TOP PLATE - BY PORTER NOTE: ALL RECESSES IN PANELS ARE 1-1/2" U.N.O. WALL 1 SIP ROOF 46'-0" WALL 2 W-5.0 1 1 W-5.0 5- 1 / 2 " R E C E S S - 6 x 6 P O S T 5- 1 / 2 " R E C E S S - 6 x 6 P O S T 5- 1 / 2 " R E C E S S - 6 x 6 P O S T 5- 1 / 2 " R E C E S S - 6 x 6 P O S T 3 W-5.0 2 W-5.0 W-5.0 2 3 W-5.0 BEVEL CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CUSTOM WIRE CHASE 16'-10"12'-8" CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E 7' - 2 3 / 8 " 2'-8 5/8"3'-6"7'-0"2'-7"3'-8"1'-4"1'-4"1'-4" 6' - 4 " 1'-5"1'-4"1'-0"1'-4" 4-5/8" SIP PANEL INSTALL PANEL FLUSH TO INSIDE OF BUILDING SIP WALL 4'-4"8'-4" 12 ' - 2 " 3-PLY 18-7/8" LVL BEAM 0.131" x 2-1/2" NAILS AT 4" O.C.0.131" x 2-1/2" NAILS AT 4" O.C. = HDU11-SDS2.5 SIMPSON HOLD DOWN ANCHOR LOCATION - SEE DETAIL 16/W5.2 BY PORTER. 0.131" x 2-1/2" NAILS AT 4" O.C. 3" R E C E S S NOTE: 1" DIAMETER ANCHOR ROD SUPPLIED AND INSTALLED BY OTHERS, EMBED PER STRUCTURAL DRAWINGS CU S T O M W I R E C H A S E WA L L 5 5 ( B . O . ) WA L L 5 2 ( B . O . ) 1'-9 3/8"1' - 9 3 / 8 " 9 5 / 8 " 10 3 / 8 " 5 5 / 8 " WA L L 5 1 ( B . O . ) WA L L 5 0 ( B . O . ) 46'-0" 0.131" x 2-1/2" NAILS AT 4" O.C. 15'-10" 6" R E C E S S - ( 2 ) J A C K S & ( 2 ) K I N G S 15'-10" 1'-4 3/4"1'-4" 10 ' - 6 " 10 ' - 6 " 7' - 4 1 / 4 " 3' - 1 3 / 4 " (2 ) 2 x 6 S P L I N E (2 ) 2 x 6 S P L I N E 4 W-5.0 7 1/16"7 1/16" WALL 4 7 1/16" 8' - 0 " 7' - 0 " 4' - 0 " 4' - 0 " 7' - 0 " 6' - 0 1 / 4 " 3' - 8 1 / 2 " 3' - 4 1 / 2 " 2' - 1 0 3 / 4 " 3" RECESS3" RECESS 31 W-5.4 30 W-5.4W-5.4 30 3'-1 3/4" 7'-4 1/4" 1'-6 7/8" 1 1/8" 2'-6 1/2" 3" RECESS 3" RECESS 11.b W-5.1 11.b W-5.1 11.b W-5.1 11.b W-5.1 (3 ) 2 X 6 S P L I N E (3 ) 2 X 6 S P L I N E (3 ) 2 X 6 S P L I N E (3 ) 2 X 6 S P L I N E 3'-6"3'-6" 4- 1 / 2 " R E C E S S - ( 2 ) J A C K S & ( 1 ) K I N G 4- 1 / 2 " R E C E S S - ( 2 ) J A C K S & ( 1 ) K I N G 11.a W-5.1 8'-0"4'-7 3/4"5'-4 1/2"3'-11 3/4"8'-0"8'-0"8'-0" 9"3'-11" W-5.0 3 W-5.0 5 W-5.0 5 WA L L 5 6 ( B . O . ) WA L L 5 9 ( B . O . ) (3 ) 2 X 6 S P L I N E (3 ) 2 X 6 S P L I N E 6 5 / 8 " 5' - 4 1 / 2 " 1' - 3 " 2' - 3 " 2' - 8 " 2' - 3 " 1' - 3 " 6' - 6 7 / 8 " 16 ' - 1 0 " 4' - 0 " 3' - 4 1 / 2 " 12 ' - 5 1 / 2 " 4' - 2 " 12 ' - 5 1 / 2 " 3' - 4 1 / 2 " 4' - 0 " 12 ' - 8 " 7' - 1 1 1 / 2 " 8' - 0 " 11 7 / 8 " 6 5 / 8 " 6 5 / 8 " 8- 1 / 2 " R E C E S S - ( 2 ) J A C K S & ( 1 ) 6 x 6 K I N G P O S T 3-PLY 14" LVL (RECESSED) 4- 1 / 2 " R E C E S S - ( 2 ) J A C K S & ( 1 ) K I N G 7'-1 5/16" W-5.2 19 3' - 1 3 / 4 " 3' - 1 3 / 4 " 11.c W-5.1 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 3' - 0 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 6 5/8"7'-8"28'-4 1/4"9'-11 3/4"6 5/8" 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 3' - 0 " 7'-8"30'-8"7'-8" 3-PLY 14" LVL (RECESSED) 8' - 2 3 / 8 " NOTE: DUE TO SEISMIC CATEGORY D, CONSTRUCTION ADHESIVE IS NOT PERMITTED AT THE SIP PANEL JOINT CONNECTIONS. HOWEVER, CONSTRUCTION ADHESIVE IS ALLOWED WHEN JOINING MULTI-PLY LUMBER PIECES TOGETHER. STAPLES ARE NOT PERMITTED AT THE SIP PANEL JOINTS, ONLY SPECIFIED NAILS. = STHD14 SIMPSON HOLDDOWN ANCHOR LOCATION (BY OTHERS) - SEE DETAIL 1/W-5.0 & 2/W-5.0 Project architect to coordinate with PorterSIP designer for custom wire chase locations and openings greater than 4”x4” for plumbing and mechanical trades. It shall not be assumed it is the designer’s responsibility. Plumbing inside the SIP panel cavity is not allowed; however, it is allowed to pass perpendicular through the SIP panel. The use of furring panels or stud wall is a possible solution to accommodate these trades. 4'-4 7/8"¯ 0 1/8"+ 4' - 5 " INFILL PANEL (x42) 17 ' - 3 9 / 1 6 " 16 ' - 7 " 1 1 / 2 " 11 ' - 1 1 3 / 8 " 1 1 / 8 " 4' - 5 " 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 007 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION ELEVATIONS REVISION DATE W-2.3 1/4" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) NOTE: ALL RECESSES IN PANELS ARE 1-1/2" U.N.O. SIP ROOF WA L L 2 WA L L 4 PRE-FABRICATED WOOD TRUSSES AT 32" O.C. 6-5/8" SIP INFILL PANELS BETWEEN TRUSSES - (42) 6-5/8" SIP PANELS PROVIDED AT 2'-6 1/2" WIDE. TRIM TO FIT SMALLER TRUSS SPACING 113'-0" W-5.0 1 1-1/8" DOUBLE TOP PLATE - BY PORTER W-5.0 3 W-5.0 6 WALL 3 1'-6"3'-6 3/8"11 3/8"11 3/8"3'-6 3/8"1'-6" WALL 5 WALL 6 WALL 7 WALL 8 WALL 9 WALL 10 WA L L 5 WA L L 6 WA L L 9 WA L L 1 0 WALL 11 WALL 12 BEVEL BEVEL WALL 13 WALL 14 WALL 15 WALL 16 WALL 17 WA L L 1 5 WA L L 1 5 16'-0" 6 5/8"15'-5 3/8" INFILL PANEL (x42) BEVELED CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E CU S T O M W I R E C H A S E 6'-4"8'-8"2'-7"6'-10"3'-0" 12 ' - 2 " 12 ' - 2 " 12 ' - 2 " 1 1 / 2 " 11 ' - 1 1 3 / 8 " 1 1 / 8 " 1 1 / 2 " 11 ' - 1 1 3 / 8 " 1 1 / 8 " 1 1 / 2 " 11 ' - 1 1 3 / 8 " 1 1 / 8 " 1 1 / 2 " 11 ' - 1 1 3 / 8 " 1 1 / 8 " 12 ' - 2 " WA L L 5 4 ( B . O . ) WA L L 5 3 ( B . O . ) WALL 20 & 26 (2 PCS) 1'-8"1'-0"1'-7"5" 6 5 / 8 " 6 5 / 8 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 7' - 1 0 3 / 4 " 8' - 0 " 8' - 0 " 8' - 0 " 6 5 / 8 " 6 5 / 8 " 1 1 / 2 " 18 ' - 4 1 / 2 " 18 ' - 6 " 1 1 / 2 " 18 ' - 4 1 / 2 " 18 ' - 6 " 7'-3 1/2" 7'-3 1/2" 1' - 2 1 / 4 " + 3'-0" 0.131" X 2-1/2" NAILS @ 4" O.C. 5' - 1 1 3 / 4 " 5' - 7 7 / 8 " + 15'-5 3/8"6 5/8" 5' - 7 7 / 8 " + 5' - 1 1 3 / 4 " 16'-0" 2'-6 1/2" 1' - 9 " 1'-8 9/16" 0 7/16" 1'-9" WALL 18 & 19 (2 PCS)WALL 21 - 25 (5 PCS) 24'-0"7'-3" 31'-3" 0 1/8"+ 1'-2 1/8" 22'-5" 0 1/8"+ 5'-7 3/4" 5' - 7 7 / 8 " + 23'-10 7/8"19'-8 7/8" 43'-7 3/4" 29 W-5.4 1' - 4 " = STHD14 SIMPSON HOLDDOWN ANCHOR LOCATION (BY OTHERS) - SEE DETAIL 1/W-5.0 & 2/W-5.0 19 W-5.2 WALL 60 WALL 61 4'-10" 4' - 1 0 " 4'-10" 4' - 1 0 " 4'-9 7/8"¯ 0 1/8"+ 4'-9 7/8"¯ 0 1/8"+ 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 4' - 4 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 3' - 0 " 7'-1 3/8"4'-0"21'-11"24'-0"24'-0"23'-9"7'-1 3/8" 6 5/8"6'-8 7/8" 6'-8 7/8"6 5/8" 5' - 1 7 / 8 " ¯ 0 3/4" 5'-1 1/8"¯ 3'-0 3/4"+ 3'-0" 0 3/4"+3' - 0 3 / 4 " + NOTE: DUE TO SEISMIC CATEGORY D, CONSTRUCTION ADHESIVE IS NOT PERMITTED AT THE SIP PANEL JOINT CONNECTIONS. HOWEVER, CONSTRUCTION ADHESIVE IS ALLOWED WHEN JOINING MULTI-PLY LUMBER PIECES TOGETHER. STAPLES ARE NOT PERMITTED AT THE SIP PANEL JOINTS, ONLY SPECIFIED NAILS. 18 ' - 6 " Project architect to coordinate with PorterSIP designer for custom wire chase locations and openings greater than 4”x4” for plumbing and mechanical trades. It shall not be assumed it is the designer’s responsibility. Plumbing inside the SIP panel cavity is not allowed; however, it is allowed to pass perpendicular through the SIP panel. The use of furring panels or stud wall is a possible solution to accommodate these trades. 3'-5 1/2" 0 1/8"+ 3' - 5 5 / 8 " + 22'-10"2'-0"10"1'-0"22'-10"2'-0"10"1'-0" 3'-0" 1'-2 7/16" 0 1/8"+4' - 2 9 / 1 6 " + 4' - 2 9 / 1 6 " + 3'-0" 1'-2 7/16" 0 1/8"+ 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 008 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION ELEVATIONS REVISION DATE W-2.4 1/4" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... PERMIT SET ENGINEERING SEAL (IF REQ'D) NOTE: ALL RECESSES IN PANELS ARE 1-1/2" U.N.O. 6-5/8" SIP BUMP OUT PANELS 7'-10 1/8" WA L L 5 1 ( B . O . ) WALL 50 WALL 51 WALL 52 WALL 53 WALL 54 WALL 55 W-5.0 1 W-5.0 1 WALL 56 WALL 57 WALL 58 WALL 59 * SEE DETAIL 21/W-5.3 FOR BUMP OUT PANEL TO WALL CONNECTION WA L L 5 0 ( B . O . ) 7'-10 1/8" 1 1 / 2 " 18 ' - 4 1 / 2 " 1 1 / 2 " 18 ' - 4 1 / 2 " 18 ' - 6 " 18 ' - 6 " WA L L 5 6 ( B . O . ) WA L L 5 9 ( B . O . ) TYP.9' - 5 " 7'-11 3/4"2'-0" 9'-11 3/4" 1'-6"5'-8 1/2"9 1/4" W-5.0 3 5'-9"5'-9" NOTE: NO WIRE CHASES IN BUMP OUT PANELS, UNLESS SHOWN OTHERWISE. 6 5/8"7'-8"7'-8" 8'-2 5/8" 4'-0"4'-2 5/8" CU S T O M W I R E C H A S E 3' - 6 1 1 / 1 6 " 4' - 1 5 / 1 6 " 8'-2 5/8" 4'-0"4'-2 5/8" 7'-8" 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " 1 1 / 2 " 21 ' - 4 1 / 2 " 21 ' - 6 " NOTE: DUE TO SEISMIC CATEGORY D, CONSTRUCTION ADHESIVE IS NOT PERMITTED AT THE SIP PANEL JOINT CONNECTIONS. HOWEVER, CONSTRUCTION ADHESIVE IS ALLOWED WHEN JOINING MULTI-PLY LUMBER PIECES TOGETHER. STAPLES ARE NOT PERMITTED AT THE SIP PANEL JOINTS, ONLY SPECIFIED NAILS. Project architect to coordinate with PorterSIP designer for custom wire chase locations and openings greater than 4”x4” for plumbing and mechanical trades. It shall not be assumed it is the designer’s responsibility. Plumbing inside the SIP panel cavity is not allowed; however, it is allowed to pass perpendicular through the SIP panel. The use of furring panels or stud wall is a possible solution to accommodate these trades. DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E ST E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 010 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION ROOF PLAN REVISION DATE W-3.1 3/16" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... NOTE: NO WIRE CHASES IN SIP ROOFPERMIT SET ENGINEERING SEAL (IF REQ'D) A B 1 2 1 SCALE: 3/16" = 1'-0" ROOF PLAN (8-9/16" SIP U.N.O.) - 19/32" OSB BOTTOM SKIN 15'-10 3/4"24'-0"24'-0"24'-0"24'-0" 6 5/8"111'-10 3/4"6 5/8" 46'-0" 1'-6" 1'-6" SPAN OF PANELS 3" R E C E S S F O R ( 2 ) 2 x A T P A N E L T O P E D G E F O R M S T C S T R AP - S E E D E T A I L 1 3 - C / W - 5 . 1 3" R E C E S S F O R ( 2 ) 2 x A T P A N E L T O P E D G E F O R M S T C S T R AP - S E E D E T A I L 1 3 - C / W - 5 . 1 PARAPAET SIP WALLS - SEE WALL PLAN & ELEVATION FOR DETAILS (2) MSTC SIMPSON STRAPS AT 2x JOINT SIDE EDGE - SEE DETAIL 13-A / W-5.1 W-5.0 5 6 W-5.0 7 W-5.0 27 W-5.3 3 W-5.0 PRE-FABRICATED WOOD TRUSSES AT 32" O.C. MAX. SPACING C C B B A A D D NOTE: FOR NON-CONTINUOUS SUB-FASCIA LUMBER BETWEEN PANEL JOINTS, ATTACH (2)-2X8 SUBFASCIA LUMBER WITH A MINIMUM 4'-0" STAGGERED JOINTS ATTACHED W/ (3) ROWS OF 3”x 0.131” NAILS @ 4" O.C. FOR 4'-0" IN EACH DIRECTION FROM JOINT. 113'-0" (2) MSTC SIMPSON STRAPS AT 2x JOINT SIDE EDGE - SEE DETAIL 13-A / W-5.1 (2) MSTC SIMPSON STRAPS AT 2x JOINT SIDE EDGE - SEE DETAIL 13-A / W-5.1 (TOP FACE - SEE DETAIL 13-B/W-5.1)(TOP FACE - SEE DETAIL 13-B/W-5.1) NOTE: ROOF MOUNTED CONDENSING UNITS ARE ACCOUNTED FOR LOADING. ATTACH CONDENSER UNITS PER DETAIL 27 / W-5.3 (2) 2x8's - 3" RECESS (2) 2x8's - 3" RECESS (1) 2x8 (1) 2x8 450 LBS RCU 450 LBS RCU RCU 450 LBS 450 LBS RCU RCU 450 LBS RCU 450 LBS RCU 450 LBS RCU 450 LBS 3 W-5.0 27 W-5.3 3" RECESS 3" RECESS 3" RECESS 3" RECESS 3" RECESS 12 W-5.1 W-5.0 5 46'-0" 1'-6" 1'-6" 6 5 / 8 " 6' - 8 7 / 8 " 6 5 / 8 " 31 ' - 3 " 43 ' - 7 3 / 4 " 22 ' - 5 " 6 5 / 8 " 6' - 8 7 / 8 " 6 5 / 8 " 39'-1 1/8"43'-7 3/4"30'-3 1/8" NOTE: E.O.R. FOR PROJECT TO PROVIDE TRUSS MANUFACTURER WITH ALL APPLIED TRUSS LOADINGS AND PERTINENT INFORMATION (BY OTHERS). REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF MECHANICAL EQUIPMENT FASTEN 2x8(s) AT THIS ADJOINING PANEL SEAM w/ (2) 3" x 0.131" NAILS AT 6" O.C. 3" RECESS 3" RECESS NOTE: DUE TO SEISMIC CATEGORY D, CONSTRUCTION ADHESIVE IS NOT PERMITTED AT THE SIP PANEL JOINT CONNECTIONS. HOWEVER, CONSTRUCTION ADHESIVE IS ALLOWED WHEN JOINING MULTI-PLY LUMBER PIECES TOGETHER. STAPLES ARE NOT PERMITTED AT THE SIP PANEL JOINTS, ONLY SPECIFIED NAILS. Project architect to coordinate with PorterSIP designer for custom wire chase locations and openings greater than 4”x4” for plumbing and mechanical trades. It shall not be assumed it is the designer’s responsibility. Plumbing inside the SIP panel cavity is not allowed; however, it is allowed to pass perpendicular through the SIP panel. The use of furring panels or stud wall is a possible solution to accommodate these trades. W-5.2 15 DOAS 1,279 lbs. RTU 1,726 lbs. 50'-1 3/8"17'-5"44'-4 3/8" 3' - 4 1 / 2 " 5' - 4 " DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E ST E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 011 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION SECTIONS REVISION DATE W-4.0 1/4" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) PRE-FABRICATED WOOD TRUSS AT 32" O.C. MAX. 46'-0" .25 / 12 PITCH 1-1/8" DOUBLE TOP PLATE - BY PORTER RIPPED TO 6-5/8" 2x TREATED PLATE - BY PORTER (TYP.) SECTION A-A SIP FILL-IN PANEL BETWEEN TRUSSES PRE-FABRICATED WOOD TRUSS AT 32" O.C. MAX. RIPPED TO 6-5/8" 2x TREATED PLATE - BY PORTER (TYP.) SECTION B-B 46'-0" .25 / 12 PITCH 1-1/8" DOUBLE TOP PLATE - BY PORTER 3-PLY 18-7/8" LVL 1-1/8" DOUBLE TOP PLATE - BY PORTER 1-1/8" DOUBLE TOP PLATE - BY PORTER 1 W-5.0 W-5.0 1 6 W-5.0 6 SIP FILL-IN PANEL BETWEEN TRUSSES 12 ' - 2 " 1'-6" SIP FILL-IN PANEL BETWEEN TRUSSES SIP FILL-IN PANEL BETWEEN TRUSSES 12 ' - 2 " 7'-6 1/8"8'-0"8'-0"8'-0"8'-0"8'-0" W-5.0 8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"1'-0 1/8" WA L L 1 WA L L 1 WA L L 3 WA L L 3 WA L L 1 3 WA L L 1 5 18 ' - 6 " 18 ' - 6 " 18 ' - 6 " 23 ' - 0 " 3'-0" 3'-1 3/4" 7'-4 1/4" 1'-6 7/8" 1 1/8" 4'-5 3/4" 8 9/16" TYP. TYP. W-5.0 7 W-5.0 7 12'-2" 4'-5 3/8" 8 9/16" 1'-2 1/16" 17 ' - 3 1 5 / 1 6 " 12'-2" 3'-5 1/2" 8 9/16" 2'-1 15/16" 16 ' - 4 1 / 1 6 " 12'-2" 3'-5 1/2" 8 9/16" 2'-1 15/16" 16 ' - 4 1 / 1 6 " 17 ' - 4 5 / 1 6 " 5' - 7 1 1 / 1 6 " 5' - 7 1 3 / 1 6 " + 2' - 1 1 3 / 1 6 " ¯ 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS M I C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E ST E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 012 SCALE DATE 11/12/2024 ORDER NUMBER - POSITION SECTIONS REVISION DATE W-4.1 1/4" = 1'-0" Ci r c l e K Y e l m W A DAG . . . . ... ... ... ... WIRE CHASE HORIZONTAL WIRECHASE @ 16" & 44" VERTICLE WIRECHASE @APPROX. 48" O.C.PERMIT SET ENGINEERING SEAL (IF REQ'D) PRE-FABRICATED WOOD TRUSS AT 32" O.C. MAX. .25 / 12 PITCH 1'-6"46'-0" SECTION C-C RIPPED TO 6-5/8" 2x TREATED PLATE - BY PORTER (TYP.) 1-1/8" DOUBLE TOP PLATE - BY PORTER 1-1/8" DOUBLE TOP PLATE - BY PORTER SECTION D-D 113'-0" PRE-FABRICATED WOOD TRUSS AT 32" O.C. MAX. RIPPED TO 6-5/8" 2x TREATED PLATE - BY PORTER (TYP.) 1 W-5.0 6 W-5.0 1 W-5.0 5 SIP FILL-IN PANEL BETWEEN TRUSSES SIP FILL-IN PANEL BETWEEN TRUSSES W-5.0 7'-6 1/8"8'-0"8'-0"8'-0"8'-0"8'-0" 5 W-5.0 24'-0"24'-0"24'-0"24'-0"15'-10 3/4" WA L L 1 3 WA L L 1 WA L L 6 WA L L 3 WA L L 2 WA L L 4 18 ' - 6 " 18 ' - 6 " 18 ' - 6 " 8 9/16" 7 W-5.0 TYP. TYP. W-5.0 5 9' - 2 3 / 8 " 9' - 3 5 / 8 " 10 ' - 6 " 14" 3-PLY LVL HEADER - BY PORTER 12'-2" 4'-5 3/8" 8 9/16" 1'-2 1/16" 17 ' - 3 1 5 / 1 6 " 16 ' - 4 1 / 1 6 " 12'-2" 3'-5 1/2" 8 9/16" 2'-1 15/16" 1" DIAMETER - WIRE CHASE CENTERED IN FOAM TYPICAL 6 5/8" DETAIL 2 7/8" 5 3/4" DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 013 SCALE DATE ORDER NUMBER - POSITION REVISION DATE Ci r c l e K Y e l m W A NTS DETAILS 11/12/2024 W-5.0 DAG . . . . ... ... ... ... 3 1-1/2" PANEL-TO-PANEL CONNECTION WITH INSUL-SPLINE 4 PANEL-TO-PANEL CONNECTION WITH DOUBLE LUMBER 1 1/2" 5 ENGINEERING SEAL (IF REQ'D) UNLESS SPECIFICALLY NOTED ON THE PO AND/OR PORTERCORP SALES ORDER, ALL NAILS, SCREWS, STAPLES AND/OR LUMBER AS SHOWN IN DETAILS ARE TO BE PROVIDED BY OTHERS. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS ROOF TO WALL CONNECTION @ SIDE WALL LEDGER PERMIT SET 2 5- 1 / 2 " CORNER CONNECTION SPACING LOCATION SEE W-5.2 & INTERIOR/EXTERIOR WALLS ROOF PANELS TO TRUSSES TYPE SIPTP 10" SCREW SIPTP 8" SCREW 12" O.C. U.N.O.ALL WALL CORNERS - TYP. SIPTP 12" SCREW PARAPET TO BLOCKING 6 7 REAR WALL SIP CONNECTION FRONT WALL SIP CONNECTION ELEV. 12'-2"ELEV. 12'-2" ELEV. 12'-2" 45.0 45.0 CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D 1 4-1/2" SIMPSON STHD14 HOLD-DOWN ANCHOR PANEL ON SLAB DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 014 SCALE DATE ORDER NUMBER - POSITION REVISION DATE Ci r c l e K Y e l m W A NTS DETAILS 11/12/2024 W-5.1 DAG . . . . ... ... ... ... 12 PANEL-TO-PANEL CONNECTION AT C/L OF TRUSSES 14 ENGINEERING SEAL (IF REQ'D) UNLESS SPECIFICALLY NOTED ON THE PO AND/OR PORTERCORP SALES ORDER, ALL NAILS, SCREWS, STAPLES AND/OR LUMBER AS SHOWN IN DETAILS ARE TO BE PROVIDED BY OTHERS. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS INTERIOR FRAMED WALL TO SIP WALL CONNECTION PERMIT SET 8 13 SIMPSON MSTC40 STRAP DETAIL DETAIL A STRAP APPLIED TO SIDE OF PANEL DOUBLE STRAP APPLIED TO TOP SKIN DETAIL B SINGLE STRAP APPLIED TO TOP SKIN DETAIL C SPACING LOCATION SEE W-5.2 & INTERIOR/EXTERIOR WALLS ROOF PANELS TO TRUSSES TYPE SIPTP 10" SCREW SIPTP 8" SCREW 12" O.C. U.N.O.ALL WALL CORNERS - TYP. SIPTP 12" SCREW PARAPET TO BLOCKING SCREEN WALL CONNECTION 9 10 3-PLY LVL FASTENING PATTERN 2" 2" 1 3/4" 5-1/2" WIDE 3-PLY LVL FASTENING PATTERN 11 TYPICAL CONSTRUCTION OF ROUGH OPENING INCLUDING (LVL) HEADER LEFT RIGHT RIGHTLEFT RIGHTLEFT CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY DNOT USEDDBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 015 SCALE DATE ORDER NUMBER - POSITION REVISION DATE Ci r c l e K Y e l m W A NTS DETAILS 11/12/2024 W-5.2 DAG . . . . ... ... ... ... 15 ENGINEERING SEAL (IF REQ'D) UNLESS SPECIFICALLY NOTED ON THE PO AND/OR PORTERCORP SALES ORDER, ALL NAILS, SCREWS, STAPLES AND/OR LUMBER AS SHOWN IN DETAILS ARE TO BE PROVIDED BY OTHERS. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS RTU SUPPORT DETAILS PERMIT SET 16 5- 1 / 2 " HDU11-SDS2.5 AT CORNERSSIMPSON HDU14 HOLD DOWN 17 MID-WALL CONNECTION DETAIL CORNER CONNECTION 18 7 1 / 1 6 " 3 5/16" 19 RTU UNIT SPACING LOCATION SEE W-5.2 & INTERIOR/EXTERIOR WALLS ROOF PANELS TO TRUSSES TYPE SIPTP 10" SCREW SIPTP 8" SCREW 12" O.C. U.N.O.ALL WALL CORNERS - TYP. SIPTP 12" SCREW PARAPET TO BLOCKING SIP INFILL PANEL 1- 1 / 2 " 20 MAIN BUILDING ROOF ATTACHMENT SCHEDULE CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D (1) # 14 SIP SCREW AT: ROOF ATTACHMENT TO LONG FRONT & REAR WALLS / PARAPET: ASCE 7-16 ROOF ATTACHMENT SCHEDULE: 9" O.C. 3 3 0.2h ZONE 3: 12" O.C. ROOF ATTACHMENT TO TRUSSES: ZONE 1: ZONE 2: (1) # 14 SIP SCREW AT:24" O.C. (1) # 14 SIP SCREW AT: (1) # 14 SIP SCREW AT: 24" O.C. (1) # 14 SIP SCREW AT: 33 1 1 1 12 1' 2 2 2 0.6h 0.6h 0.6h 0. 6 h 0. 2 h h = 16'-8" 0.2h = 3'-4" 0.6h = 10'-0" ZONE 1': 12" O.C. ROOF ATTACHMENT TO SHORT SIDE WALLS / PARAPET: 12" O.C.(2) # 14 SIP SCREWS AT: DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 016 SCALE DATE ORDER NUMBER - POSITION REVISION DATE Ci r c l e K Y e l m W A NTS DETAILS 11/12/2024 W-5.3 DAG . . . . ... ... ... ... ENGINEERING SEAL (IF REQ'D) UNLESS SPECIFICALLY NOTED ON THE PO AND/OR PORTERCORP SALES ORDER, ALL NAILS, SCREWS, STAPLES AND/OR LUMBER AS SHOWN IN DETAILS ARE TO BE PROVIDED BY OTHERS. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS PERMIT SET 21 6-5/8" SIP BUMP OUT TO 6-5/8" SIP WALL CONNECTION 18 " BOX FOR SWITCH OR OUTLET ELECTRICAL INSTALLATION 22 23 24 25 FULL LENGTH OF PANEL - X'-X" (VARIES) 3'-0" FULL LENGTH OF PANEL - X'-X" (VARIES) PLAN VIEW 3'-0" 26 SUBFASCIA LUMBER AT ROOF STRAP ATTACHMENT AT TOP SIDE 27 CONDENSER SUPPORT DETAIL CONDENSING UNIT SPACING LOCATION SEE W-5.2 & INTERIOR/EXTERIOR WALLS ROOF PANELS TO TRUSSES TYPE SIPTP 10" SCREW SIPTP 8" SCREW 12" O.C. U.N.O.ALL WALL CORNERS - TYP. SIPTP 12" SCREW PARAPET TO BLOCKING UNFRAMED ROOF PENETRATION 1" MIN. 6" MAX. PARAPET FRAMING / SHEATHING 45.0 4' - 1 0 " M I N . DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 017 SCALE DATE ORDER NUMBER - POSITION REVISION DATE Ci r c l e K Y e l m W A NTS DETAILS 11/12/2024 W-5.4 DAG . . . . ... ... ... ... ENGINEERING SEAL (IF REQ'D) UNLESS SPECIFICALLY NOTED ON THE PO AND/OR PORTERCORP SALES ORDER, ALL NAILS, SCREWS, STAPLES AND/OR LUMBER AS SHOWN IN DETAILS ARE TO BE PROVIDED BY OTHERS. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS PERMIT SET SPACING LOCATION SEE W-5.2 & INTERIOR/EXTERIOR WALLS ROOF PANELS TO TRUSSES TYPE SIPTP 10" SCREW SIPTP 8" SCREW 12" O.C. U.N.O.ALL WALL CORNERS - TYP. SIPTP 12" SCREW PARAPET TO BLOCKING 2 1/4" 1 1/2" PANEL-TO-PANEL CONNECTION WITH (3)-2x LUMBER FOR BATHROOM GRAB BAR 28 29 LADDER CONNECTION DETAIL SIP SILL PANEL DETAIL WINDOW FRAME TREATED PLATE 1ST BOTTOM PLATE DOOR FRAME 2ND BOTTOM PLATE 6" M I N . 6" SIP SILL PANEL DETAIL WITH DOOR 30 WINDOW FRAME 3' - 1 3 / 4 " 6" M I N . 6" TREATED PLATE 2ND BOTTOM PLATE 1ST BOTTOM PLATE 31 10 " M I N . PARAPET FRAMING / SHEATHING 32 1' - 8 " M I N . 33 PARAPET FRAMING / SHEATHING 45.0 45.0 CONSTRUCTION SEALANT SHOWN, BUT SHOULD NOT BE USED FOR THIS PROJECT DUE TO IT BEING SIESMIC CATEGORY D DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024 81280 - 018 SCALE DATE ORDER NUMBER - POSITION REVISION DATE Ci r c l e K Y e l m W A NTS DETAILS 11/12/2024 W-5.5 DAG . . . . ... ... ... ... ENGINEERING SEAL (IF REQ'D) UNLESS SPECIFICALLY NOTED ON THE PO AND/OR PORTERCORP SALES ORDER, ALL NAILS, SCREWS, STAPLES AND/OR LUMBER AS SHOWN IN DETAILS ARE TO BE PROVIDED BY OTHERS. CLICK CODE TO REFERENCE WEBSITE FOR INSTALLATION GUIDE, NTA REPORT OR CONSTRUTION DETAILS / TECHNICAL BULLETINS PERMIT SET SPACING LOCATION SEE W-5.2 & INTERIOR/EXTERIOR WALLS ROOF PANELS TO TRUSSES TYPE SIPTP 10" SCREW SIPTP 8" SCREW 12" O.C. U.N.O.ALL WALL CORNERS - TYP. SIPTP 12" SCREW PARAPET TO BLOCKING 34 BABY CHANGING STATION ATTACHMENT TO SIP WALL 8 1 / 4 " 35 PARAPET FRAMING / SHEATHING 45.0 4' - 1 0 " M I N . DBA Pinnacle Engineering, Inc. Engineering Company License Number 21006421 8180 Corporate Park Drive Suite 235 Cincinnati, Ohio 45242 (513) 984-1663 wwww.pinneng.com projects@pinneng.com AWFO ETATS MI C H A E L STREIC H E N E N G I N EER IS EF O R P SHIN T O N R E S T E R E D G 24015241 G I S O LA R 11/11/2024