Circle K - Yelm (Yelm & Killion), WA - Structural OTPJOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S0.1 PROJECT NUMBER: 24212 GENERAL NOTES CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB C. THE DUTIES OF THE SPECIAL INSPECTOR SHALL INCLUDE, BUT ARE NOT LIMITED TO, VERIFICATION OF CONSTRUCTION QUALITY CONTROL, TESTING, COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS, BUILDING CODE REQUIREMENTS, AND LOCAL BUILDING DEPARTMENT REQUIREMENTS. D. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE PROPER NOTIFICATION TO THE SPECIAL INSPECTOR AND PROCEED WITH THE CONSTRUCTION ONLY AFTER THE SPECIAL INSPECTOR'S APPROVAL. E. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR: 1. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE INSPECTOR MAY NOT ALTER, MODIFY, ENLARGE OR WAIVE ANY OF THE REQUIREMENTS OF THE DOCUMENTS. 2. SPECIAL INSPECTORS SHALL KEEP RECORDS OF INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE CONSTRUCTION OFFICIAL, AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE, THE CONTRACTOR AND THE OWNER. REPORTS SHALL INDICATE THAT WORK INSPECTED WAS DONE IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR AND THE OWNER FOR CORRECTION, IF THE DISCREPANCIES ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE AND THE OWNER PRIOR TO THE COMPLETION OF THAT PHASE OF THE WORK. 3. A FINAL REPORT OF INSPECTIONS DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS SHALL BE SUBMITTED PERIODICALLY AT A FREQUENCY AGREED UPON BY THE PERMIT APPLICANT AND THE BUILDING OFFICIAL PRIOR TO THE START OF WORK. WHERE SPECIAL INSPECTION REQUIREMENTS DUPLICATE THE REQUIREMENTS OF SPECIFIED QUALITY ASSURANCE TESTING, DUPLICATE INSPECTIONS SHALL NOT BE REQUIRED. 11. STRUCTURAL ENGINEER OF RECORD (SER) NOTIFICATION OF CONSTRUCTION PROGRESS AND SITE VISIT (WHEN APPLICABLE): A. CONTRACTOR SHALL NOTIFY ARCHITECT FIVE (5) WORKING DAYS PRIOR TO THE FOLLOWING CONSTRUCTION MILESTONES: 1. SPREAD FOOTING FOUNDATIONS: AFTER FOUNDATION REINFORCING IS PLACED AND BEFORE PLACING CONCRETE AT THE FOUNDATIONS. 2. WOOD WALL CONSTRUCTION: AFTER WALL STUDS ARE ERECTED AND BEFORE INTERIOR SHEATHING IS PLACED. 3. ROOF STRUCTURE: AFTER STRUCTURE IS ERECTED AND BEFORE INSULATION AND ROOFING IS INSTALLED. CONTRACTOR SHALL ARRANGE A PRE-ROOFING MEETING BEFORE ANY ROOFING WORK IS STARTED. 4. PUNCH LIST: AFTER ALL STRUCTURAL ITEMS ARE COMPLETE. B. FAILURE TO NOTIFY ARCHITECT OF ANY CONSTRUCTION MILESTONE MAY RESULT IN CONTRACTOR HAVING TO REMOVE WORK FOR THE PURPOSE OF REVIEW AT CONTRACTOR'S EXPENSE. C. PREMATURE NOTIFICATION FOR SITE VISIT WILL RESULT IN AN ADDITIONAL SITE VISIT WITH ALL EXPENSES AND FEES PAID BY THE CONTRACTOR. 12. SIPS PANELS A. THE STRUCTURAL INSULATED PANEL (SIPS) SUPPLIER SHALL BE CERTIFIED BY THE STRUCTURAL INSULATED PANEL ASSOCIATION (SIPA) PRIOR TO THE START OF PRODUCTION OF PANELS AND SHALL HAVE A MINIMUM OF TW O YEARS OF EXPERIENCE PRODUCING PANELS. B. SIPS PANELS SHALL COMPLY WITH THE PERFORMANCE AND DESIGN CRITERIA IN THE CONTRACT DOCUMENTS. SIPS SUPPLIER SHALL ENGAGE A QUALIFIED PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED TO DESIGN ALL STRUCTURAL COMPONENTS AND CONNECTIONS. SIPS PANELS SHALL WITHSTAND THE EFFECTS OF ALL DESIGN LOADS WITHOUT EXCEEDING THE ALLOWABLE WORKING STRESSES. SIP PANEL DEFLECTIONS SHALL BE LIMITED TO A MAXIMUM DEFLECTION OF L/240 OF THE SPAN. C. THE SIPS SUPPLIER SHALL PRODUCE A COMPLETE SET OF SEALED SHOP DRAWINGS AND CALCULATIONS FOR REVIEW BY THE EOR. THE SHOP DDRAWINGS SHALL INCLUDE ALL INFORMATION REQUIRED TO PROPERLY INSTALL THE PANELS, AND ANY DETAILS AND ALL DESIGN LOADINGS REQUIRED FOR INTERFACING WITH THE BUILDING FOUNDATION AND SLAB SYSTEM. D. THE PANELS SHALL BE BRACED DURING INSTALLATION. BRACING TO BE DESIGNED BY THE SIPS SUPPLIER AND SHALL REVIEW THE INSTALLATION PROCEDURES WITH THE GENERAL CONTRACTOR TO ENSURE PROPER INSTALLATION. E. SIP PANEL MANUFACTURER SHALL BE APPROVED TO PERFORM WORK WITHOUT SPECIAL INSPECTION. AT COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE OWNER OR THE OWNER'S AUTHORIZED AGENT FOR SUBMITTAL TO THE BUILDING OFFICIAL AS SPECIFIED IN SECTION 1704.5 STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. G. VAPOR BARRIER, IF NOT SPECIFIED BY ARCHITECTURAL SPECIFICATION OR SOILS REPORT SHALL CONSIST OF A MINIMUM 15 MIL ASTM E1745 CLASS A MATERIAL LAPPED A MINIMUM OF 6" AND TAPED PER MANUFACTURER RECOMMENDATIONS. THE BARRIER SHALL BE PLACED ON TOP OF COMPACTED AGGREGATE BASE COURSE. THE FLOOR SLAB SHALL BE PLACED ON TOP OF THE VAPOR BARRIER. ANY DAMAGE TO VAPOR BARRIER SHALL BE REPAIRED PRIOR TO SLAB PLACEMENT. CARE SHALL BE TAKEN TO KEEP MOISTURE AWAY FROM THE COMPACTED SUBBASE. SUBGRADE MUST BE ALLOWED TO DRY AFTER RAINS PRIOR TO SLAB PLACEMENT. FLOOD CURING IS NOT ALLOWED. SAND IS NOT AN ALTERNATIVE FOR THE SUB-BASE COURSE. H. UNLESS NOTED, FLOOR CONTRACTION JOINTS FOR SLAB-ON-GRADE SHALL BE SPACED EQUALLY. CONTRACTION JOINTS SPACING SHALL BE REDUCED AT HOT AND/OR DRY CLIMATE. SAW CUT SLAB (1/8" WIDE X SLAB THICKNESS/4 U.N.O.) AS SOON AS THE SURFACE IS FIRM ENOUGH SO THAT IT WILL NOT BE DAMAGED BY THE BLADE. JOINT FILLER SHALL BE PLACED IN CLEAN JOINTS, OVERFILLED AND SHAVED FLUSH. THE OPTIMUM TIME TO CUT THE SLAB WILL BE THE CONTRACTOR'S RESPONSIBILITY. SLABS WITH CRACKS AND/OR SLAB WHICH EXHIBIT "SLAB CURLING" WILL NOT BE ACCEPTED. SLAB REPLACEMENT SHALL BE AT OPTION OF THE OWNER AT CONTRACTOR'S EXPENSE. I. REF ARCHITECTURAL AND CIVIL DRAWINGS FOR SIDEWALKS, EXTERIOR SLABS, INTERIOR SLABS, SLAB DEPRESSIONS, AND ELEVATIONS. J. SLAB-ON-GRADE AT CORNERS OF OPENINGS, CUT OUTS AND PENETRATIONS SHALL BE REINFORCED WITH 2-#4 (3'-0" LONG). K. AT SLAB-ON-GRADE, SEAL COLUMN BOX-OUTS, CONSTRUCTION JOINTS AND CONTRACTION JOINTS TO PREVENT WATER PENETRATION UNDER SLAB DURING & AFTER CONSTRUCTION TO PREVENT SOILS FROM EXPANDING. L. PIPES, DUCTS, CONDUITS, ETC. SHALL NOT BE PLACED IN SLABS UNLESS APPROVED BY THE STRUCTURAL ENGINEER. (PLACE A MINIMUM 4" BELOW SLAB). M. THE GENERAL CONTRACTOR, INCLUDING SUB CONTRACTORS AND SUPPLIERS SHALL NOT DRIVE OR PARK HEAVY EQUIPMENT ON THE CONCRETE SLAB. ANY DAMAGE TO SLAB DUE TO HEAVY EQUIPMENT SHALL BE REPLACED AT CONTRACTOR'S EXPENSE. N. COMBUSTION HEATERS SHALL NOT BE USED DURING CONCRETE PLACEMENT UNLESS PRECAUTIONS ARE TAKEN TO PREVENT EXPOSURE OF THE CONCRETE TO EXHAUST GASES. O. REF ARCH SPECIFICATIONS FOR ALL FLOOR SLAB FINISHES. P. PROVIDE NEW TROWEL BLADES FOR CONCRETE FINISHING OF FLOOR SLABS. 7. POST-INSTALLED ANCHORING SYSTEM: A. UNLESS NOTED, ALL ANCHORS IN CONCRETE SHALL BE CARBON STEEL HILTI KWIK HUS-EZ SCREW ANCHORS PER ICC ESR-3056 OR APPROVED ICC EQUIVALENT. B. WHERE NOTED ON THE DRAWINGS FOR CONCRETE ANCHORAGE, USE HILTI HIT HY-100 THREADED ROD ADHESIVE ANCHORING SYSTEM (ICC ESR-3574) OR APPROVED ICC EQUIVALENT. UNLESS NOTED, ANCHOR EMBEDMENT SHALL BE AS FOLLOWS: 3/8" DIA. - 3 3/8", 1/2" DIA. - 4 1/2", 5/8" DIA. - 5 5/8", 3/4" DIA. - 6 3/4". C. UNLESS NOTED, ANCHOR SPACING (AS) AND ANCHOR EDGE DISTANCE (ED) SHALL BE AS PUBLISHED BY THE MOST CURRENT APPROVED HILTI REPORT IN ORDER TO DEVELOP MAXIMUM WORKING LOAD. D. ALL ANCHORS SHALL BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS AND UNDER MANUFACTURER'S SUPERVISION IN ORDER TO DEVELOP THE PUBLISHED WORKING LOADS. E. MINIMUM CONCRETE COMPRESSIVE STRENGTH REQUIRED AT TIME OF INSTALLATION OF ANY ANCHORS SHALL BE 2500 PSI. 8. WOOD FRAMING: A. ALL NAILING NOT NOTED SHALL BE PER TYPICAL DETAIL AND COMMON NAIL DIAMETER TABLE BELOW. ALL BOLTING SHALL BE PER STRUCTURAL STEEL SECTION ABOVE. WOOD CONNECTORS SHALL BE AS MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT AND EQUIVALENT ICC APPROVAL. WHERE "TYPE" OF CONNECTOR IS INDICATED ON THE DRAWINGS, THE CONNECTOR AND ATTACHMENT SHALL BE PER THE MAXIMUM MODEL NUMBER BASED ON THE SIZE OF THE MEMBERS CONNECTED. B. WOOD FRAMING MEMBERS SHALL NOT BE NOTCHED OR DRILLED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. NAIL TYPE REQ'D DIA REQ'D GA LENGTH NAIL TYPE REQ'D DIA REQ'D GA LENGTH 6d 0.113" 11 1/2 2" 12d 0.148" 9 3 1/4" 8d 0.131" 10 1/4 2 1/2" 16d 0.162" 8 3 1/2" 10d 0.148" 9 3" 20d 0.192" 6 4" C. WOOD STUDS AND TRUSSES SHALL HAVE A MAXIMUM MOISTURE CONTENT OF 19% WHEN DELIVERED TO THE JOB SITE. D. PRESERVATIVE-TREATED WOOD: 1. ALL SILL PLATES IN CONTACT WITH CONCRETE SHALL BE PRESERVATIVE-TREATED WOOD. WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY OR CONCRETE WALLS BELOW GRADE SHALL BE PRESERVATIVE-TREATED WOOD. 2. ALL WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING THAT ARE IN CONTACT WITH EXTERIOR WALLS AND ARE LESS THAN 8 INCHES FROM FINISHED GRADE SHALL BE PRESERVATIVE-TREATED WOOD. 3. ALL FASTENERS INCLUDING NUTS AND WASHERS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE HOT-DIPPED ZINC-COATED GALVANIZED STEEL OR STAINLESS STEEL. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE PER ASTM A153. FASTENERS OTHER THAN NAILS, WOOD SCREWS AND LAG SCREWS ARE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC-COATED STEEL WITH COATING WEIGHTS PER ASTM B695, CLASS 55 MINIMUM. 4. ALL FASTENERS INCLUDING NUTS AND WASHERS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE HOT-DIPPED ZINC-COATED GALVANIZED STEEL OR STAINLESS STEEL. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE PER ASTM A153. FASTENERS OTHER THAN NAILS, WOOD SCREWS AND LAG SCREWS ARE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC-COATED STEEL WITH COATING WEIGHTS PER ASTM B695, CLASS 55 MINIMUM. E. FRAMING LUMBER SHALL COMPLY WITH THE REFERENCED EDITION OF THE GRADING RULES OF THE WWPA OR THE WCLIB. ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY AND SHALL HAVE MINIMUM PROPERTIES WHICH MEET OR EXCEED THE FOLLOWING WOOD TYPES: 1. EXTERIOR WALL STUDS: DOUGLAS FIR-LARCH (DF-L) No. 2 OR BETTER, OR SOUTHERN PINE No. 2 OR BETTER. 2. HEADERS: DOUGLAS FIR-LARCH (DF-L) No. 2 OR BETTER, OR SOUTHERN PINE No. 2 OR BETTER. 3. BEARING PLATES AND TOP PLATES: DOUGLAS FIR-LARCH (DF-L) No. 2 OR BETTER, OR SOUTHERN PINE No. 2 OR BETTER. 9. PREFABRICATED WOOD TRUSS FRAMING MEMBERS: A. FRAMING MEMBERS SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS STATED IN THE GENERAL STRUCTURAL NOTES OR AS LOCATED ON PLANS. BRIDGING SIZE AND SPACING BY FABRICATOR UNLESS NOTED OTHERWISE. ALL CONNECTORS SHALL HAVE CURRENT ICC APPROVAL. FRAMING MEMBERS SHALL BE AGENCY STAMPED AND CONFORM TO THE REFERENCED BUILDING CODE AND ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL CONNECTED WOOD TRUSS CONSTRUCTION." CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER IN THE PROJECT LOCATION STATE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. SAID SUBMITTAL, IN ADDITION TO LOADS SPECIFIED IN THE G.S.N. AND PLANS, SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 1. DEFLECTION/CAMBER: ROOFS WITHOUT PLASTER OR GYPBOARD CEILINGS TOTAL LOAD MAXIMUM = L/180, LIVE LOAD MAXIMUM = L/240. ROOFS WITH PLASTER OR GYPBOARD CEILINGS TOTAL LOAD MAXIMUM = L/240, LIVE LOAD MAXIMUM = L/360. FABRICATOR SHALL DESIGN ROOF MEMBERS FOR PONDING WHERE ROOF SLOPES ARE LESS THAN 1/4" PER FOOT. FRAMING MEMBERS SHALL BE CAMBERED FOR 1.0 TIMES THE DEAD LOAD DEFLECTION. MAXIMUM TOTAL LOAD DEFLECTION OF MEMBERS SHALL BE 1"; FABRICATOR SHALL DESIGN ADJACENT MEMBERS FOR MAXIMUM OF 1/4" DIFFERENTIAL DEFLECTION. 2. TOP CHORD MEMBER WOOD SPECIES SHALL HAVE A SPECIFIC GRAVITY OF 0.42 OR GREATER. B. VERIFY SIZE, WEIGHT AND LOCATION OF SUPPORTED EQUIPMENT WITH ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL, SPRINKLER AND THEIR RELATED DRAWINGS. ADDITIONAL FRAMING MEMBERS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT EQUIPMENT. C. FABRICATOR SHALL HAVE ICC APPROVAL OR BE APPROVED ACCORDING TO THE BUILDING JURISDICTION. 10. SPECIAL INSPECTIONS: A. SPECIAL INSPECTOR (SI) SHALL BE RETAINED AND PAID BY THE OWNER AND PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER SECTION 1704 OF THE IBC AS PER TABLE ON S0.3. B. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. D. CONTRACTOR TO PREPARE SUBGRADE FOR BUILDING PAD AND PAVING AREAS PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. THE SITE SHALL BE PREPARED UNIFORMLY IN ACCORDANCE WITH CIVIL DRAWINGS. E. WHERE FILL IS REQUIRED IT SHALL BE PLACED IN ACCORDANCE WITH RECOMMENDATIONS AND UNDER THE OBSERVATION OF A QUALIFIED GEOTECHNICAL ENGINEER. F. ALL EXCAVATIONS AND BUILDING PADS SHALL BE OBSERVED BY A QUALIFIED GEOTECHNICAL ENGINEER TO VERIFY THE DESIGN CRITERIA AND REPORT ADVERSE CONDITIONS. (GEOTECHNICAL ENGINEER TO BE HIRED AND PAID BY THE OWNER) CERTIFICATION OF EXCAVATION SHALL BE PROVIDED TO BUILDING OFFICIAL. IN CASE OF CONFLICT BETWEEN THE GEOTECHNICAL REPORT, SPECIFICATIONS AND DRAWINGS, THE MORE STRINGENT REQUIREMENT SHALL APPLY. G. FOOTING ELEVATIONS GIVEN ARE FOR PURPOSE OF CONTRACT AND SHALL BE ADJUSTED (LOWERED) AT TIME OF EXCAVATION TO MEET SOIL CONDITIONS. ENGINEER SHOULD BE CONSULTED. H. GRANULAR BASE BELOW SLAB-ON-GRADE AND SPREAD FOOTINGS SHALL BE PLACED AND COMPACTED IN ACCORDANCE WITH THE RECOMMENDATIONS AND UNDER THE OBSERVATION OF A QUALIFIED GEOTECHNICAL ENGINEER. I. BACKFILL AGAINST WALLS SHALL BE DEPOSITED EVENLY AGAINST BOTH SIDES OF THE WALLS UNTIL THE LOWER GRADE IS REACHED. J. THE CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ARCHITECT THE LOCATION OF EXISTING UTILITIES AND PROCEED WITH THE WORK ONLY AFTER WRITTEN APPROVAL FROM THE ARCHITECT. K. EXCAVATIONS FOR CONTINUOUS FOOTINGS SHALL BE MADE TRUE TO LINE AND GRADE. THE SIDES OF THE FOOTINGS SHALL BE FORMED, EXCEPT WHERE SOIL CONDITIONS ARE SUCH THAT THE SIDES OF THE EXCAVATION STAND FIRM AND SQUARE. EXCAVATIONS SHALL BE MADE TO FIRM, CLEAN BEARING SOIL. L. EXCAVATIONS FOR FOOTINGS AND FOUNDATIONS, WHICH ARE TO SERVE AS FORMS, SHALL BE THOROUGHLY WET PRIOR TO PLACING CONCRETE. 4. CONCRETE: A. CONCRETE SHALL CONFORM WITH ACI BUILDING CODE (ACI-318) AND SHALL HAVE A 28-DAY COMPRESSIVE STRENGTH, AND DENSITY, AND WATER/CEMENT IN ACCORDANCE WITH THE FOLLOWING: LOCATION STRENGTH, PSI DENSITY, PCF MAX W/C RATIO INTERIOR SLABS 3000 145 0.55 FOUNDATIONS 3000 145 0.55 ALL OTHER CONCRETE (UNO) 3000 145 0.55 NOTE: DESIGN STRENGTH BASED ON 2,500 PSI CONCRETE B. UNLESS NOTED, CEMENT SHALL CONFORM TO ASTM C150, TYPE I OR II. AGGREGATES SHALL BE NORMAL WEIGHT CONFORMING TO ASTM C33. ADMIXTURES CONTAINING CHLORIDES SHALL NOT BE USED. C. CONCRETE EXPOSED TO WEATHER (I.E., EXPOSED EXTERIOR SLABS, CONCRETE WALLS, RETAINING WALLS, ETC.) SHALL BE AIR-ENTRAINED IN ACCORDANCE WITH ACI 318. D. UNLESS NOTED, MAXIMUM SLUMP FOR CONCRETE SHALL BE 4 INCHES (PLUS OR MINUS ONE INCH) AT POINT OF PLACEMENT. WHERE APPROVED BY THE ENGINEER OF RECORD, LARGER SLUMP IS PERMITTED WITH THE ADDITION OF HIGH RANGE WATER REDUCING ADMIXTURE. E. CONCRETE CURING SHALL COMPLY WITH ACI 308. CURING PROCESS SHALL START IMMEDIATELY FOLLOWING INITIAL SET. CONCRETE SHALL BE MAINTAINED IN MOIST CONDITION FOR AT LEAST 7 DAYS AFTER PLACEMENT UNLESS PROVISIONS OF ACI-318 ARE FOLLOWED. F. HOT WEATHER CONCRETING: SPECIAL PRECAUTIONS RECOMMENDED BY ACI 305 SHALL BE TAKEN WHEN THE AMBIENT TEMPERATURE IS ABOVE 80 DEGREES FAHRENHEIT OR WHEN MAXIMUM RATE OF EVAPORATION IN THE CONCRETE EXCEEDS 0.2 LB/SF/HR. THIS RATE IS AFFECTED BY AIR TEMPERATURE, RELATIVE HUMIDITY, CONCRETE TEMPERATURE AND WIND VELOCITY. AFTER FINISHING CONCRETE, USE LIGHT FOG SPRAY UNTIL CURING COMPOUND IS USED, OR WET CURING METHOD IS IMPLEMENTED. G. COLD WEATHER CONCRETING: WHEN, FOR MORE THAN THREE (3) CONSECUTIVE DAYS, THE MEAN DAILY TEMPERATURE DROPS BELOW 40 DEGREES FAHRENHEIT, SPECIAL MATERIALS AND PROCEDURES SHALL BE PROVIDED DURING PLACING AND CURING OF CONCRETE PER ACI 306. 5. REINFORCING STEEL: A. REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60 (U.N.) AND GRADE 40 FOR #3 AND SMALLER BARS. GRADE 60 REINFORCING MAY NOT BE RE-BENT OR FIELD BENT WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. B. WELDED WIRE REINFORCING SHALL CONFORM TO ASTM A-1064, MINIMUM LAP SHALL BE 8" U.N.O. C. REINFORCING THAT IS WELDED SHALL BE WELDABLE TYPE, ASTM A-706. D. NO TACK WELDING OF REINFORCING IN THE FIELD WILL BE PERMITTED. E. ALL DETAILING, FABRICATION AND PLACING OR REINFORCING BARS, UNLESS OTHERWISE NOTED, SHALL CONFORM TO ACI 318, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" AND THE LATEST ACI "MANUAL OF STANDARD PRACTICE FOR DETAIL REINFORCED CONCRETE STRUCTURES". F. MINIMUM LAP SPLICE AND TENSION DEVELOPMENT DIMENSION TABLE BASED ON 3000 PSI NORMAL WEIGHT CONCRETE, Fy = 60 KSI, NON-COATED BARS, LAP CLASS B, WITH 3" MIN CLR: BAR TOP BAR SPLICE DEVELOPMENT BAR OTHER BAR SPLICE DEVELOPMENT #3 21" 16" #3 16" 12" #4 23" 18" #4 18" 14" #5 28" 22" #5 22" 17" #6 34" 26" #6 26" 20" WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLER BAR OR THE ANCHORAGE DIMENSION OF THE LARGER BAR. USE WHICHEVER DIMENSION IS LARGER. G. MINIMUM CONCRETE COVER FOR REINFORCING CONCRETE REINFORCING SHALL BE PLACED PER THE TOLERANCES OF ACI 117 AND ACI 318 LOCATION MINIMUM COVER FOOTINGS, GRADE BEAMS AND SLABS CAST AGAINST & PERMANENTLY EXPOSED TO EARTH 3" SLABS ON GRADE MID-DEPTH INTERIOR SLABS AND STAIRS 1" EXTERIOR SLABS AND STAIRS #5 AND SMALLER 1 1/2" EXTERIOR SLABS AND STAIRS #6 AND LARGER 2" WALLS INTERIOR FACE 1" WALLS INTERIOR FACE #5 AND SMALLER 1 1/2" WALLS INTERIOR FACE #6 AND LARGER 2" *VERIFY W/ ENVIRONMENTAL CONDITIONS PER ACI 318, CHAPTER 19. 6. SLABS: A. MAXIMUM SLUMP WITHOUT A PLASTICIZER AT POINT OF PLACEMENT SHALL BE 5 INCHES. MIX DESIGNS SHALL TAKE CARE TO PROVIDE THE LARGEST POSSIBLE SIZE OF COARSE AGGREGATE WHILE MAINTAINING CONCRETE WORKABILITY. NOMINAL MAXIMUM AGGREGATE SIZE SHALL NOT BE LESS THAN 3/4 INCH NOR MORE THAN 1/3 THE DEPTH OF THE SLAB. B. FOR INTERIOR SLABS ON GRADE, PROVIDE CONCRETE WITH AN ULTIMATE SHRINKAGE LES THAN 0.05% AT 28 DAYS. LABORATORY TEST RESULTS SHALL BE SUBMITTED INDICATING THAT THE CONCRETE SLAB ON GRADE MIX DESIGN (OR COMPARABLE) MEETS THE ULTIMATE SHRINKAGE REQUIREMENTS. SHRINKAGE VALUES FOR CONCRETE SPECIMENS SHALL BE TESTED PER ASTM C157 AND THE PROCEDURES IN ACI 209R TO PREDICT THE ULTIMATE DRYING SHRINKAGE. C. CONCRETE SHALL BE MIXED, PLACED, FINISHED AND CURED PER REFERENCED EDITION OF ACI 302.1 FOR THE APPROPRIATE FLOOR CLASS TYPE. CURING COMPOUND SHALL BE COMPATIBLE WITH ARCHITECTURAL FLOOR FINISH. SLABS SHALL BE PLACED ON A FLAT, SMOOTH, FIRM, COMPACTED SUBGRADE. D. FOR SUBGRADE AND SUBBASE PREPARATION, SEE GEOTECHNICAL REPORT AND SPECIFICATIONS. E. IMMEDIATELY PRIOR TO POURING EACH SLAB, A QUALIFIED GEOTECHNICAL ENGINEER (TO BE PAID BY OWNER) SHALL INSPECT THE PAD AND PROVIDE A CERTIFICATE STATING THAT THE PAD MEETS THE PROJECT DESIGN REQUIREMENTS. IF WEATHER CONDITIONS CHANGE, RE-CERTIFICATION WILL BE REQUIRED. F. SLAB-ON-GRADE REINFORCING SHALL BE SUPPORTED ON CHAIRS AT MID-DEPTH OF SLAB WITH SAND PLATES OR PRECAST CONCRETE SUPPORTS (PRECAST CONCRETE SUPPORTS SHOULD BE AT LEAST 4" SQUARE AT THE BASE W /MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI) OF SUFFICIENT HEIGHT TO INSURE THAT REINFORCING IS AT THE PROPER HEIGHT WITH MAXIMUM SPACING OF 3'-0" EACH WAY FOR WELDED WIRE FABRIC. PLACEMENT OF REINFORCING USING THE PULL- UP METHOD IS NOT PERMITTED. 1. GENERAL: A. APPLICABLE STRUCTURAL CODE: WASHINGTON STATE BUILDING CODE - 2021 EDITION (BASED ON THE 2021 IBC), IN CONJUNCTION WITH ASCE 7-16 AND LOCAL AMENDMENTS. B. THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. EXCEPT WHERE NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE STRUCTURAL ENGINEER OF RECORD SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS). C. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE REFERENCED EDITION AND/OR ADDENDA. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A REGISTERED ENGINEER RECOGNIZED BY THE BUILDING CODE JURISDICTION OF THIS PROJECT. D. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPENCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. E. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, AND ELECTRICAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL REQUIREMENTS INTO THE SHOP DRAWINGS AND CONSTRUCTION. F. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. G. CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE RESPONSIBILITY OF THE DISCIPLINES WHO ARE MAKING THESE ATTACHMENTS. THESE ATTACHMENTS SHALL BE DESIGNED TO RESIST ALL GRAVITY, WIND, WIND UPLIFT, THERMAL LOADS, ETC. H. WHERE A DETAIL, TYPICAL DETAIL, SECTION, TYPICAL SECTION OR A NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. I. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS WITH THE ARCHITECTURAL DRAWINGS & FIELD CONDITIONS. BUILDING DIMENSIONS AND ELEVATIONS, WHERE SHOWN, WERE PROVIDED BY THE ARCHITECT AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE RESOLVED THROUGH THE ARCHITECT. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING AND ELECTRICAL ITEMS WITH THE APPROPRIATE TRADE DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. J. ENGINEER'S REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC. DOES NOT RELIEVE THE CONTRACTOR FROM MEETING THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITING OF ANY SPECIFIC DEVIATIONS AND OBTAIN ENGINEER'S WRITTEN APPROVAL FOR THE SPECIFIC DEVIATION. K. UNLESS NOTED, SUBMIT SHOP DRAWINGS OF ALL FABRICATED MATERIALS FOR REVIEW. DESIGN DRAWINGS SHALL NOT BE REPRODUCED FOR USE AS SHOP DRAWINGS. SHOP DRAWINGS WILL NOT BE REVIEWED UNLESS THEY WERE CHECKED, BEAR THE INITIAL OF THE CHECKER AND ARE STAMPED "APPROVED" BY THE GENERAL CONTRACTOR. L. ALL REQUIRED TESTING REPORTS SHALL BE AVAILABLE AT THE JOB SITE. M. NO SUPPORT PROVISIONS HAVE BEEN MADE FOR EQUIPMENT OVER 300 POUNDS OR PIPES OVER 4" DIAMETER EXCEPT AS SHOWN. UNLESS NOTED, EQUIPMENT SHALL BE SUPPORTED BY TWO (2) BEAMS OR TRUSSES WHERE EACH SUPPORTS HALF OF THE EQUIPMENT WEIGHT. ANY ADDITIONAL REQUIREMENTS SHOULD BE APPROVED BY THE ENGINEER. EQUIPMENT AND PIPES SHALL BE BRACED LATERALLY BY THE INSTALLER TO RESIST SEISMIC FORCES. N. EQUIPMENT WEIGHTS SHOWN ON THE STRUCTURAL DRAWINGS ARE MAXIMUM OPERATING WEIGHTS INCLUDING CURBS AND MISCELLANEOUS ITEMS. THE CONTRACTOR SHALL VERIFY AND BRING TO THE ATTENTION OF THE ENGINEER ANY DEVIATIONS. O. WHERE ROOF DRAINS ARE USED FOR ROOF DRAINAGE, AN EMERGENCY DRAINAGE SYSTEM SHALL BE PROVIDED TO MINIMIZE WATER ACCUMULATION (REF ARCHITECTURAL DRAWINGS). P. JOHNSTON BURKHOLDER ASSOCIATES, ITS EMPLOYEES, AND REPRESENTATIVES SHALL NOT BE RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION MEANS AND METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH CONSTRUCTION; NOR WILL THEY BE RESPONSIBLE FOR ANY FAILURE BY THE CONTRACTOR TO PERFORM OR COMPLETE CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. JOBSITE VISITS BY JOHNSTON BURKHOLDER ASSOCIATES SHALL NOT CONSTITUTE APPROVAL, AWARENESS, OR LIABILITY FOR ANY HAZARDOUS CONDITIONS. 2. DESIGN CRITERIA: A. DEAD LOADS - REF FRAMING PLAN B. LIVE LOADS - ROOF = 20 PSF C. RISK CATEGORY = II D. SNOW LOADS 1. GROUND SNOW LOAD = 18 PSF 2. FLAT-ROOF SNOW LOAD = 17.6 PSF 3. SNOW EXPOSURE FACTOR, Ce = 1.0 4. THERMAL FACTOR, Ct = 1.0 (MAIN BUILDING) 5. SNOW LOAD IMPORTANCE FACTOR, I = 1.0 6. ALL APPLICABLE EFFECTS DUE TO SNOW DRIFTING E. WIND LOADS 1. CODE MINIMUM ULTIMATE WIND SPEED = 97 MPH 2. DESIGN ULTIMATE WIND SPEED = 115 MPH 3. WIND LOAD IMPORTANCE FACTOR = 1.0 4. WIND EXPOSURE CATEGORY = C FOR MAIN WIND FORCE-RESISTING SYSTEM 5. WIND EXPOSURE CATEGORY = C FOR COMPONENTS AND CLADDING F. SEISMIC LOADS 1. SEISMIC IMPORTANCE FACTOR, I = 1.0 2. MAPPED SPECTRAL RESPONSE ACCELERATIONS - Ss = 1.294 - S1 = 0.467 3. SITE CLASS = D 4. DESIGN SPECTRAL RESPONSE PARAMETERS - Sds = 0.863 - Sd1 = 0.571 5. SEISMIC DESIGN CATEGORY = D 6. BASIC SEISMIC-FORCE-RESISTING SYSTEM = LIGHT FRAME WOOD WALLS WITH STRUCTURAL WOOD SHEAR PANELS 7. DESIGN BASE SHEAR, V = Cs*W 8. SEISMIC RESPONSE COEFFICIENT, Cs = 0.133 9. RESPONSE MODIFICATION FACTOR, R = 6.5 10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE ANALYSIS G. DESIGN LOAD COMBINATIONS (ASD) 1. D 2. D + (Lr OR S OR R) 3. D + (0.6W OR 0.7E) 4. D + 0.75(Lr OR S OR R) + 0.75(0.6W OR 0.7E) 5. 0.6D + 0.6W 6. 0.6D + 0.7E STRESS INCREASES: INCREASES IN ALLOWABLE STRESSES SPECIFIED IN THE APPROPRIATE MATERIAL CHAPTER OR THE REFERENCED STANDARDS SHALL NOT BE USED WITH THE LOAD COMBINATIONS, EXCEPT THAT A DURATION OF LOAD INCREASE SHALL BE PERMITTED IN ACCORDANCE WITH CHAPTER 23. 3. SHALLOW FOUNDATIONS AND BUILDING PAD: A. THE FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS MADE IN THE GEOTECHNICAL ENGINEERING INVESTIGATION PREPARED BY MOORE TWINING ASSOCIATES, INC, DATED MARCH 20, 2024. B. CONTINUOUS FOOTINGS AND SPREAD FOOTINGS SHALL BEAR ON SOIL CAPABLE OF SUSTAINING A NET ALLOWABLE BEARING PRESSURE OF 2,500 PSF AT A DEPTH OF 18 INCHES. C. MAXIMUM TOTAL FOUNDATION AND SLAB SETTLEMENT 1" AND DIFFERENTIAL SETTLEMENT 1/2" OVER A DISTANCE OF 50 FEET. MINIMUM SUBGRADE MODULUS 100 PCI. PARAMETERS SHALL BE VERIFIED BY A QUALIFIED GEOTECHNICAL ENGINEER. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPORT ADVERSE CONDITIONS. GENERAL NOTES OTP 11/12/24 11/12/24 ROOF TOP UNIT (RTU) INDICATES CONCENTRATED LOAD; REF NOTES FOOTING MARK; REF SCHEDWFX OFOP OUTSIDE FACE OF PANEL AND CONCRETE STEM WALL APPROXIMATE LOCATION OF SHEAR WALL HOLD DOWN. REF SIPS PANEL DRAWINGS FOR HOLD DOWN DETAILS AND EXACT LOCATIONS 4 6 55 4.6 FT 4.6 FT WALL PARAPET COMPONENT AND CLADDING WIND PRESSURE DIAGRAM -WALLS NOTES: 1. THE VALUES PROVIDED HEREIN ARE ALLOWABLE STRESS DESIGN LOADS (ALREADY INCLUDE 0.6 FACTOR) AND ARE INTENDED FOR SERVICEABILITY LIMITS. THESE VALUES DO NOT REFLECT THE ULTIMATE LOADING THAT MAY BE EXPERIENCED BY THE BUILDING. 2. THE ROOFING SYSTEM SHALL BE BASED ON AN EFFECTIVE WIND AREA OF 10 SF. C&C ZONE EFFECTIVE WIND AREA (SF) POSITIVE PRESSURE (PSF) 10 1 20 50 100 +10.0 +10.0 +10.0 +10.0 NEGATIVE PRESSURE (PSF) -28.0 -26.2 -23.7 -21.9 C&C ZONE EFFECTIVE WIND AREA (SF) POSITIVE PRESSURE (PSF) 10 4 20 50 100 +16.1 +15.4 +14.4 +13.7 NEGATIVE PRESSURE (PSF) -17.4 -16.7 -15.8 -15.1 10 2 20 50 100 +16.1 +15.4 +14.4 +13.7 -37.0 -34.6 -31.4 -29.1 10 5 20 50 100 +16.1 +15.4 +14.4 +13.7 -21.5 -20.0 -18.2 -16.7 10 3 20 50 100 +16.1 +15.4 +14.4 +13.7 -50.5 -45.8 -39.5 -34.7 10 6 20 50 100 +51.3 +48.0 +43.6 +40.3 -34.6 -32.3 -29.3 -27.0 RO O F W A L L S COMPONENT AND CLADDING WIND PRESSURE SCHEDULE (115 MPH) 12 2 2 2 333 10' - 0" 10 ' - 0 " 10 ' - 0 " 10' - 0" COMPONENT AND CLADDING WIND PRESSURE DIAGRAM -ROOF 3 3 3 3 TYP AT CORNERS 3' - 6" 10' - 0" 10 ' - 0 " 10 ' - 0 " 10' - 0" TRUSS NET WIND UPLIFT NET PRESSURE DIAGRAM (115 MPH) TYP AT CORNERS 3' - 6" 27.5 PSF AT CORNER ZONES, TYP 14.7 PSF 21.9 PSF 21.9 PSF 27.5 PSF ROOF DL AND RLL/SLL PER GENERAL NOTES ROOF NET WIND UPLIFT = REF 1-S0.2 FOR ROOF NET UPLIFT PRESSURES (SERVICE LEVEL) PREFABRICATED ROOF TRUSS BY TRUSS SUPPLIER NOTES: 1. REF FRAMING PLAN FOR LOCATION OF MECH EQUIPMENT POINT LOADS ARE ADDITIONAL AND TO BE INCLUDED IN TRUSS DEAD LOAD. 2. REF SIPs PANEL FOR ADDITIONAL LOADS TO THE WOOD TRUSSES 3. DESIGN ALL TRUSSES FOR 300 LB POINT LOAD ANYWHERE ALONG TRUSS, FOR FUTURE MECH ROOFTOP EQUIPMENT 9'-11" ALL FOUR SIDES SNOW DRIFT (AT PARAPETS ONLY) 40 . 2 P S F JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S0.2 PROJECT NUMBER: 24212 DIAGRAMS AND SCHEDULES CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB ABBREVIATIONS AB ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE AFF ABOVE FINISHED FLOOR AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE ARCH ARCHITECTURAL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY BFF BELOW FINISHED FLOOR BL BLOCK LINTEL BM BEAM BO BOTTOM OF BOS BOTTOM OF STEEL BRG BEARING CJ CONTRACTION JOINT CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE COND CONDENSER UNIT CONST CONSTRUCTION CONT CONTINUOUS DBA DEFORMED BAR ANCHOR DIA DIAMETER EF EXHAUST FAN EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL EQ EQUAL EW EACH WAY FDN FOUNDATION FF FINISHED FLOOR FS FAR SIDE FTG FOOTING FV FIELD VERIFY GA GAUGE GC GENERAL CONTRACTOR GYP GYPSUM BOARD H HEIGHT HORIZ HORIZONTAL HSA HEADED STUD ANCHOR HSS HOLLOW STRUCTURAL SHAPE INFO INFORMATION ISO ISOLATION JBE JOIST BEARING ELEVATION JST JOIST JT JOINT KSI KIPS PER SQUARE INCH L LENGTH LB POUNDS LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LONG LONGITUDINAL MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANOUS MO MASONRY OPENING MTL METAL NIC NOT IN CONTRACT NO NUMBER NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFOP OUTSIDE FACE OF PANEL OH OPPOSITE HAND OSL OUTSTANDING LEG PAF POWER ACTUATED FASTENER PC PRECAST PCF POUNDS PER CUBIC FOOT PL PLATE PLF POUNDS PER LINEAR FOOT PLUMB PLUMBING PMEJ PREMOLDED EXPANSION JOINT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH QTY QUANITY RCU REFRIGERATION CONDENSING UNIT REF REFER TO REINF REINFORCING REQD REQUIRED REV REVERSE RLL ROOF LIVE LOAD RO ROUGH OPENING ROT ROTATE RTU ROOF TOP UNIT SCHED SCHEDULE SDI STEEL DECK INSTITUTE SIM SIMILAR SIP STRUCTURAL INSULATED PANEL SJI STEEL JOIST INSTITUTE SPCS SPACES SPECS SPECIFICATIONS STRUC STRUCTURAL T&B TOP AND BOTTOM THK THICKNESS TL TOTAL LOAD TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FOOTING TOGB TOP OF GRADE BEAM TOS TOP OF STEEL TOW TOP OF WALL TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL W WIDTH WP WORK POINT WWR WELDED WIRE REINFORCEMENT LEGEND NTS 1COMPONENTS & CLADDING WIND PRESSURES 3/4" = 1'B0" 2TYPICAL WOOD TRUSS LOADING DIAGRAM OTP 11/12/24 11/12/24 1. HIGH-LOAD DIAPHRAGMS: A. VERIFY GRADE AND THICKNESS OF PANEL SHEATHING, NOMINAL SIZE OF FRAMING MEMBERS AT ADJOINING PANEL EDGES, THE NAIL DIAMETER AND LENGTH, THE MEMBER OF FASTENER LINES AND THAT THE SPACING BETWEEN FASTENERS IN EACH LINE AND AT EDGE MARGINS. - VERIFICATION AND INSPECTION FREQUENCY REFERENCED STANDARD CONCRETE CONSTRUCTION (ACI 318-19) VERIFICATION AND INSPECTION FREQUENCY REFERENCED STANDARD 1. INSPECTION OF REINFORCING STEEL AND PLACEMENT PERIODIC 4A. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS - ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. INSPECTIONS SHALL INCLUDE HOLE SIZE AND DEPTH, CLEANING PROCEDURE, MATERIALS, AND LOCATION. CONTINUOUS 3. INSPECTION OF ANCHORS CAST IN CONCRETE INCLUDING, SIZE, LENGTH, PROJECTION, AND LOCATION.PERIODIC 5. INSPECTION TO VERIFY USE OF REQUIRED DESIGN MIX.PERIODIC 6. INSPECTION PRIOR TO CONCRETE PLACEMENT, AND AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS, FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. REF TO GENERAL NOTES, CAST-IN-PLACE CONCRETE EXECUTION FOR TESTING REQUIREMENTS. 7. INSPECTION OF CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.CONTINUOUS 8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.PERIODIC 10. INSPECT ERECTION OF PRECAST (OR SITE CAST) CONCRETE MEMBERS.PERIODIC 12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.PERIODIC 4B. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS - MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4A.INSPECTIONS SHALL INCLUDE HOLE SIZE AND DEPTH, CLEANING PROCEDURE, MATERIALS, AND LOCATION. PERIODIC CONTINUOUS 2. NOT USED.- 9. NOT USED. - 11. NOT USED. - STRUCTURAL SPECIAL INSPECTIONS (2021 WASBC) WOOD CONSTRUCTION: 1. WIND-RESISTING SYSTEM AND SEISMIC RESISTING SYSTEM VERIFICATION AND INSPECTION FREQUENCY REFERENCED STANDARD WOOD LATERAL FORCE RESISTING SYSTEM: CONTINUOUS A. VERIFY NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF COMPONENTS WITH IN THE MAIN LATERAL FORCE RESISTING SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES AND HOLD-DOWN WHERE NAIL SPACING OF WOOD DIAPHRAGMS AND WOOD SHEAR WALLS IS 4" OR LESS. PERIODIC - CONTINUOUS - B. INSPECTION OF FIELD-GLUING OPERATION OF ELEMENTS OF THE MAIN WIND FORCE-RESISTING SYSTEM WHERE NAIL SPACING OF WOOD DIAPHRAGMS AND WOOD SHEAR WALLS IS 4" OR LESS. A. INSPECTION IS REQUIRED FOR THE FASTENING OF THE FOLLOWING SYSTEMS AND COMPONENTS: -i. ROOF COVERING, ROOF DECK AND ROOF FRAMING CONNECTIONS. - 2. WIND-RESISTING COMPONENTS ii. EXTERIOR WALL COVERING AND WALL CONNECTIONS TO ROOF AND FLOOR DIAPHRAGMS AND FRAMING. PERIODIC PERIODIC ACI 318: Ch 20, 25.2, 25.3, 26.6.1-26.6.3 ACI 318: 17.8.2.4 ACI 318: 17.8.2 ACI 318: CH. 19, 26.4.3, 26.4.4 ASTM C172, ASTM C31; ACI 318: 26.5, 26.12 ACI 318: 26.5 ACI 318: 26.5.3-26.5.5 ACI 318: CH. 26.9 ACI 318: 26.11.1.2(b) ACI 318: 17.8.2 - - - SOILS 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY PERIODIC - 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL PERIODIC - 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS PERIODIC - 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND COMPACTION OF COMPACTED FILL.CONTINUOUS - 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.PERIODIC - VERIFICATION AND INSPECTION FREQUENCY REFERENCED STANDARD EXCEPTIONS TO CONCRETE SPECIAL INSPECTION: 1. INSPECTION IS NOT REQUIRED FOR PLACEMENT OF SLAB-ON-GRADE CONCRETE. INSPECTION OF SLAB-ON-GRADE REINFORCEMENT IS REQUIRED PRIOR TO PLACEMENT OF CONCRETE. 2. INSPECTION IS NOT REQUIRED FOR FOR PLACEMENT OF FOUNDATION CONCRETE (DESIGN f'c OF 2,500 PSI). INSPECTION OF FOUNDATION REINFORCEMENT IS REQUIRED PRIOR TO PLACEMENT OF CONCRETE. JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S0.3 PROJECT NUMBER: 24212 TABLE OF SPECIAL INSPECTIONS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB OTP 11/12/24 11/12/24 A A B B 11 22 1' - 6 " 46 ' - 0 " 46 ' - 0 " 113' - 0" REF ARCH 7' - 3 1/2"4' - 1"90' - 3" 1010 10 10 99 8 TYP 6' - 0"CJ AT (2) EQUAL SPACES CJ AT (2) EQUAL SPACES CJ AT (3) EQUAL SPACES CJ AT (3) EQUAL SPACES 6' - 0" 1 S2.1 1 S2.1 2 S2.1 2 S2.1 3 S2.1 3 S2.1 3 S2.1 TYP TYP 1' - 6 " 3 S2.1 1 S2.0 1 S2.0 S2.0 9TYP REF 10-S2.0 FOR LIGHT POLE BASE DETAIL. REF CIVIL FOR LIGHT POLE BASE LOCATIONS. OFOPOFOP OFOPOFOP OF O P OF O P OF O P OFOPOFOP OF O P 10 6' - 0 " CJ A T ( 2 ) E Q S P A C E S CJ A T ( 2 ) E Q S P A C E S 6' - 0 " OF O P OF O P TOF EL -1' - 4" TOF EL -1' - 4" TOF EL -1' - 4" TOF EL -1' - 4" 4" CONCRETE SLAB ON GRADE WITH 6X6 -W2.1 X W2.1 WWR IN SHEETS ON CHAIRS (OVERLAP 8" MIN) CENTERED IN SLAB, OVER 15 MIL VAPOR BARRIER, OVER 4" NON-RECYCLED AGGREGATE BASE, OVER ENGINEERED FILL EXTENDING TO THE DEPTH RECOMMENDED BELOW FOUNDATIONS PER THE GEOTECHNICAL REPORT -TYP U.N.O. AT CONTRACTOR'S OPTION, CONCRETE SLAB ON GRADE CAN BE POURED MONOLITHICALLY WITH CONCRETE STEM WALLS. FINISHED FLOOR EL = PER CIVIL DRAWING REFERENCE FINISHED FLOOR EL = 0' -0" WF1 WF 1 WF1 W F 1 12 12 12 12 13 13 13 13 1 S2.1 TYP 113' - 0" OFOPOFOP 4' - 1"7' - 3 1/2" 11 11 11 11 11 14 11 REF 5-S2.2 FOR TRASH ENCLOSURE FOUNDATION DETAILS. RE F A R C H 1 S2.1TYP 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 4 S2.1 11 STRUCTURAL INSULATED PANELS (SIPS) WALL LEGEND APPROXIMATE LOCATION OF SHEAR WALL HOLD DOWN. REF SIPS PANEL DRAWINGS FOR HOLD DOWN DETAILS AND EXACT LOCATIONS JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S1.0 PROJECT NUMBER: 24212 FOUNDATION PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB 3/16" = 1'@0" 1FOUNDATION PLAN FOUNDATION PLAN NOTES NUMBER PLAN NOTE GENERAL PLAN NOTES 1 REF SHEET S0.1, S0.2 AND S0.3 FOR GENERAL NOTES, LEGEND AND SPECIAL INSPECTIONS REQUIREMENTS. 2 ALL ELEVATIONS REFERENCED FROM FINISH FLOOR ELEVATION OF 0'-0" (AT BLDG SLAB) FOR REFERENCE ONLY. 3 TOP OF FOOTING ELEVATION SHALL BE ASSUMED TO BE CONSTANT BETWEEN ELEVATIONS SHOWN ON PLAN U.N.O. (FOUNDATION REQUIREMENTS ENSCRIBED ON S0.1 PER GEOTECHNICAL ENGINEER RECOMMENDATIONS SHALL BE FOLLOWED AS GRADING CONDITIONS VARY, REF CIVIL). 4 FOR TYPICAL REINFORCING BAR BEND DETAILS, REF 4-S2.0. 5 FOR PIPING RUNNING PARALLEL AND PERPENDICULAR TO THE FOUNDATION REF 6-S2.0 & 7-S2.0. 6 THE GENERAL CONTRACTOR, INCLUDING SUBCONTRACTORS AND SUPPLIERS, SHALL NOT ALLOW ANY VEHICULAR TRAFFIC ON THE BUILDING PAD AFTER THE PAD CERTIFICATION OR THE CONCRETE SLAB ONCE PLACED. ANY DAMAGE TO THE PAD DUE TO THE VEHICULAR TRAFFIC SHALL BE REPAIRED/REPLACED AT THE EXPENSE OF THE CONTRACTOR 7 FOOTER CONTRACTOR NEEDS TO CONTACT THE ELECTRICAL CONTRACTOR SO THEY CAN INSTALL THE UFER BEFORE THE FOOTER IS INSPECTED REFERENCED PLAN NOTES 8 FOR TYPICAL FLOOR CONSTRUCTION JOINT, REF 1-S2.0; FOR TYPICAL FLOOR CONTRACTION JOINT, REF 2-S2.0. 9 COORDINATE SLAB SLOPES AT DRAIN LOCATIONS WITH THE ARCH DRAWINGS. 10 CONCRETE STEM WALL BELOW, REF DETAIL 1-S2.1 FOR DETAILS AND FACE OF WALL LOCATION. REF DETAILS 2-S2.2 THRU 4-S2.2 FOR CONCRETE STEM WALL DETAILS. 11 INDICATES SHEAR WALL HOLDDOWN; REF SIPS PANEL DRAWINGS FOR DETAILS AND EXACT LOCATIONS. ALL HOLDDOWN ANCHORS REQUIRING ANCHOR BOLTS SHALL BE EMBEDDED INTO THE CONTINUOUS FOOTING THE SPECIFIED AMOUNT SHOWN IN DETAIL 1-S2.2. 12 SIPS WALL PANELS DESIGNED TO SUPPORT ALL BUILDING CODE REQUIRED LOADS AND DESIGNED AS SHEAR WALLS TO RESIST ALL SEISMIC/WIND LOADS. 13 REF ARCH FOR ALL WALL OPENING SIZES AND LOCATIONS WITH THE ARCH DRAWINGS. REF 11-S2.0 FOR RE-ENTRANT BARS AT OPENINGS. 14 STEP TOP OF FOOTING PER 8-S2.0 AS REQUIRED FOR INSTALLATION OF CONDUIT. INSTALL SLEEVES IN CONCRETE STEM WALL FOR CONDUITS. WALL FOOTING SCHEDULE MARK WIDTH THICKNESS REINF (TRANS) REINF (LONG) REINF LOCATION WF1 2' - 0" 1' - 0" #5 AT 24" (3) #5 BOT OTP 11/12/24 11/12/24 A A B B 11 22 RTU (1760 LBS) RTU (1760 LBS) RCU (400 LBS) RCU (400 LBS) RCU (400 LBS) BO TRUSS EL REF ARCH BO TRUSS EL REF ARCH RCU (450 LBS) RCU (450 LBS) RCU (450 LBS) RCU (400 LBS) 46 ' - 0 " 46 ' - 0 " 113' - 0" 113' - 0" 7 TYP 10 10 10 8 8 4 S3.0 5 S3.0 11 9 TYP TYP TYP 12 OFOP OFOP OFOPOFOP OF O P OF O P OF O P DO U B L E T R U S S DO U B L E T R U S S OF O P RCU (400 LBS)PRE-FABRICATED ROOF TRUSSES BY SIPS SUPPLIER REF SIPS DRAWINGS FOR TRUSS LAYOUT AND ALL CONNECTION DETAILING REF ARCH FOR TOP OF SIP PANEL ELEVATIONS, TYP TYP 3 S3.0 TYP 2 S3.0TYP 2 S3.0 TYP 1/ 4 " P E R 1 2 " RO O F S L O P E 5 S3.0 5 S3.0 11 TYP 11TYP 10 TYP TYP TYP NOTE: ROOF PARAPET BRACES NOT SHOWN. REF ARCH AND SIPS DRAWINGS FOR LOCATIONS (IF APPLICABLE) DEAD LOADS MEMBRANE (UNBALASTED) = 1.0 PSF SIP PANEL = 4.0 PSF WOOD TRUSSES = 3.0 PSF MECH/ELEC/FIRE SPRINK = 5.0 PSF MISC = 4.0 PSF TOTAL = 17.0 PSF ROOF DEAD LOADS STRUCTURAL INSULATED PANELS (SIPS) WALL LEGEND APPROXIMATE LOCATION OF SHEAR WALL HOLD DOWN. REF SIPS PANEL DRAWINGS FOR HOLD DOWN DETAILS AND EXACT LOCATIONS JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S1.1 PROJECT NUMBER: 24212 ROOF FRAMING PLAN CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB 3/16" = 1'@0" 1ROOF FRAMING PLAN ROOF FRAMING PLAN NOTES NUMBER PLAN NOTE REFERENCED PLAN NOTES 7 SIP PANEL ROOF DESIGNED TO SUPPORT ALL BUILDING CODE REQUIRED LOADS AND DESIGNED AS A DIAPHRAGM TO DISTRIBUTE WIND/SEISMIC LOADS TO SHEAR WALLS. REF 1-S3.0 FOR ADDITIONAL FRAMING AT OPENINGS. 8 REF 1-S3.0 FOR RTU DUCT OPENING AND ROOF OPENING FRAMES. GC TO VERIFY LOCATION, SIZE AND WEIGHT OF MECHANICAL UNITS. OPERATING WEIGHT SHALL NOT EXCEED THE WEIGHT NOTED ON THE PLAN. 9 EXTERIOR ROOF ACCESS LADDER, REF ARCH FOR LOCATION. SIP PANEL MANUFACTURER TO COORDINATE CONNECTION. 10 DESIGN TRUSSES FOR AN ADDITIONAL 50 PSF STORAGE SHELF LOAD (RLL), TYP AT THIS STYLE HATCH. REF ARCH FOR LOCATIONS AND DETAILS. 11 INTERIOR SOFFIT FRAMING, REF ARCH FOR LOCATIONS AND REF APPLICABLE STRUC FRAMING SECTIONS FOR SUPPORT AND ADDITIONAL LOADS TO TRUSSES. 12 SOFFIT ACCESS HATCH BELOW ROOF, REF ARCH FOR SIZE AND LOCATION. ROOF FRAMING PLAN NOTES NUMBER PLAN NOTE GENERAL PLAN NOTES 1 REF SHEET S0.1, S0.2 AND S0.3 FOR GENERAL NOTES AND SPECIAL INSPECTIONS REQUIREMENTS. 2 REF ARCH DRAWINGS FOR ADDITIONAL INFORMATION AND DIMENSIONS. 3 ALL ITEMS SUCH AS MECHANICAL EQUIPMENT, DUCT WORK, PIPES, CEILINGS, FIXTURES, ETC. THAT ARE TO BE SUPPORTED OR HUNG FROM THE WOOD TRUSSES SHALL BE FRAMED WITH AUXILIARY FRAMING TO THE PANEL POINTS OF THE TRUSS. METHODS OF FRAMING THAT INDUCE BENDING TO THE TRUSS CHORD OR WEB MEMBERS WILL NOT BE PERMITTED. COORDINATE BRIDGING LOCATIONS SO AS NOT TO INTERFERE WITH ANY MECHANICAL EQUIPMENT. 4 APPROXIMATE WEIGHTS OF ROOF TOP EQUIPMENT ARE SHOW N ON PLAN. VERIFY ALL LOADS, LOCATIONS, CURB SIZES AND OPENING SIZES WITH MECHANICAL CONTRACTOR PRIOR TO FABRICATION. ADJUST SPACING OF WOOD TRUSSES AS REQUIRED FOR MECHANICAL OPENINGS. REF TYPICAL RTU SUPPORT DETAIL 2-S3.0 FOR FRAMING. 5 RTUS AND RCUS MUST BE PLACED ON OR BETWEEN TRUSSES DESIGNED FOR THE ADDITIONAL LOAD AS SHOWN. REF MECHANICAL FOR EXACT LOCATIONS. 6 PLACEMENT OF SPRINKLER CONTRACTOR'S PIPING AND TRUSS BRIDGING SHALL BE COORDINATED BY THE GENERAL CONTRACTOR. THE CONTRACTOR SHALL MAKE PROVISIONS FOR THE TRUSS SUPPLIER TO ADJUST/RELOCATE BRIDGING OR SPRINKLER CONTRACTOR TO ADJUST PIPING VERTICALLY WHERE CONFLICTS OCCUR. ALL CHANGES REQUIRED OF THE TRUSS BRIDGING SHALL BE DESIGNED BY TRUSS MANUFACTURER. OTP 11/12/24 11/12/24 1/8" RADIUS EACH SIDE OF JOINT (REQUIRED FOR ACCEPTANCE) 1/2" DIA x 1'-6" SMOOTH BARS AT 12" O.C, TYP. LOCATE BARS AT MID-DEPTH OF SLAB AND OIL ONE END ONLY (1) #4 EACH SIDE OF JOINT, DISCONTINUOUS AT CONTROL JOINTS, TYP SEALANT, REF SPECS COAT EDGE OF SLAB WITH BOND BREAKING COMPOUND BEFORE ADJACENT SLAB IS PLACED COMPACTED SUBGRADE PER GEOTECH AGGREGATE BASE PER GEOTECH VAPOR BARRIER, REF FDN PLAN CONC SLAB ON GRADE, REF FDN PLAN SLAB REINF, REF FDN PLAN NOTE: 1. SMOOTH BARS SHALL BE INSTALLED HORIZONTALLY. SL A B T EQ EQ 1/8" WIDE x 1" DEEP "SOFT CUT" EARLY ENTRY SAW-CUT JOINT, REF DETAIL 3-S2.0, TYP. AGGREGATE BASE PER GEOTECH COMPACTED SUBGRADE PER GEOTECH NOTE: 1. SPACE CONTROL JOINTS AT 12'-0" OC MAX. 2. SLAB CUTTING AS SOON AS POSSIBLE AFTER FINISHING. WITHIN 1 HOUR IN HOT WEATHER, WITHIN 4 HOURS IN COLD WEATHER. 3. JOINT FILLER SHALL BE PLACED IN CLEAN JOINTS, OVER FILLED, AND SHAVED FLUSH. VAPOR BARRIER, REF FDN PLAN CONC SLAB ON GRADE, REF FDN PLAN SLAB REINF, REF FDN PLAN T FULL DEPTH SEMI-RIGID JOINT FILLER, OVER FILL AND SHAVE FLUSH INTERIOR FILLED JOINT EXTERIOR SEALED JOINT T LE S S T H A N 1 / 4 " T/ 2 B U T N O T 1 / 8 " SEALANT, REF MANUF. SPECIFICATIONS BACKER ROD (PER SEALNT MNFR. RECOMMENDATIONS) IF REQUIRED 1/4" SECOND CUT 1/8" FIRST CUT 1 2 " D " "D " "d " 4" MIN 4 "d" OR UN O 12 " d " 90 DEGREE BAR HOOK 180 DEGREE BAR HOOK TYPICAL COLUMN BAR OFFSET 135 DEGREE BAR HOOK "D" "d " O R 4 " M I N 1 0 " d " U N O 1 2 "d " NOTE: 1. PROVIDE THESE HOOKSHROUGHOUT WORK AS INDICATED ON DRAWINGS. BAR SIZE "D" #3 THRU #8 6 "d" #9 THRU #11 8 "d" #14 THRU #18 10 "d" "d " EDGE OF SLAB AT OPENING AND CORNER (2) #4 x 3'-0" LONG AT MID-DEPTH OF SLAB (BEND AS REQUIRED TO INSTALL) E Q U A L 3 " 3 " EQUAL TRENCH FOR PIPE OR ELECTRICAL CONDUIT LARGER THAN 3" DIA FINISHED GRADE BOTTOM OF TRENCH SHALL NOT BE BELOW THIS LINE 2 1 MI N 9" CONCRETE FTG, REF FDN PLAN CONC WALL, REF FDN PLAN DE P T H FO O T I N G 3' - 0 " M A X MI N 6" MIN 3" TYP STEEL SLEEVE 2" LARGER THAN PIPE, CAULK AS REQUIRED PIPES PERPENDICULAR TO FTG STEEL PIPE SLEEVE, REF MFR MIN 9" 2-SACK SLURRY MIX (2500 PSI MIN) BELOW FOOTING, PLACE CONC AGAINST UNDISTURBED SOIL, TYP NOTE: 1. NO PIPES TO PENETRATE THRU FOOTING. 2. WHERE PIPES DO OCCUR AT FOOTING ELEVATION, STEP FOOTING DOWN SO PIPES PASS THROUGH FOOTING WALL. REF DETAIL 8-S2.0 FOR FTG STEP DETAIL. 3. MAX PIPE DIAMETER SHALL BE 6 INCHES. MIN 6" SECTION CONCRETE FTG, REF FDN PLAN CONC WALL, REF FDN PLAN MIN 48 BAR DIA MIN 2x "H" "H" "H" DEPTH FTG DEPTH FTG MIN 48 BAR DIA CLR 3" MIN FTG DEPTH FORM AND COMPACT SOIL REINFORCING SHALL MATCH SIZE AND SPACING OF REINF IN ADJACENT FOOTING SECTION PROVIDE TOP REINF ONLY WHERE NOTED TOP (WHERE APPLICABLE) AND BOTTOM HORIZ REINF, TYP 2'-0"x2'-0" CORNER BARS MATCHING HORIZ FTG REINF SIZE, TYP 2'-0"x2'-0" CORNER BARS MATCHING HORIZ FTG REINF SIZE, TYP 25'-0" TALL (MAX) LIGHT POLE AND BASE CONNECTION BY OTHERS (3) #3 TIES IN TOP 5" 3/4" CHAMFER, TYP FINISHED GRADE OR CONCRETE PAVING, REF CIVIL 24" DIA. CONCRETE CAISSON TYPE FTG WITH (5) #5 VERT AND #3 TIES AT 12" OC TYP 3" 6" 7'-0" MIN 3'-0" MAX NOTE: 1. REF CIVIL FOR LOCATION OF LIGHT POLES. 2' - 0" DIA 2" CLR3" SLAB EDGE (1) #5, LOCATE 2" BELOW TOP OF SLAB OMIT BAR WHERE CJ INTERSECTS RE-ENTRANT CORNER 10" 2 ' - 6 " JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S2.0 PROJECT NUMBER: 24212 FOUNDATION DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB 3/4" = 1'@0" 1TYPICAL CONSTRUCTION JOINT 3/4" = 1'@0" 2TYPICAL CONTRACTION JOINT 3/4" = 1'@0" 3TYPICAL CONCRETE SLAB JOINT DETAIL 3/4" = 1'@0" 4TYPICAL REINFORCING BARS BENDS DETAIL 3/4" = 1'@0" 5TYPICAL REINFORCEMENT AT SLAB OPENING 3/4" = 1'@0" 6UTILITY LINE PARALLEL TO FDN 3/4" = 1'@0" 7UTILITY LINE PERPENDICULAR TO FDN 3/4" = 1'@0" 8DETAIL AT STEPPED FOOTING 1" = 1'@0" 9CONCRETE FOOTING CORNER BAR REINFORCEMENT 3/4" = 1'@0" 10TYP LIGHT POLE FTG 3/4" = 1'@0" 11SLAB REINFORCEMENT AT DOOR OPENINGS OTP 11/12/24 11/12/24 GRID #4 DOWELS AT 18" OC WITH 90 DEGREE HOOKS INTO FTG; ALTERNATE DIRECTION CONCRETE SLAB ON GRADE, REF FDN PLAN REF WALL FTG SCHED FOR TRANS REINF REF WALL FTG SCHED FOR LONG REINF REF FDN PLAN TOF EL NOTE: 1. BOTTOM OF FOUNDATION SHALL BE PLACED PER GEOTECHNICAL RECOMMENDATIONS. FOR ADDITIONAL INFO, REF GENERAL NOTES ON SHEET S0.1. REF FDN PLAN FF EL #4 CONT AT 12" OC MAX (2 MIN) CONCRETE STEM WALL MATCHING SIPS PANEL THICKNESS (REF SIPS PANEL SUPPLIER) FACE OF SIPS PANEL = FACE OF CONC STEM WALL CL R 3" TYP 3" CLR RE F S C H E D (2) #4 HORIZ CONT AT TOP OF WALL EQ EQ REF ARCH FOR FINISH MATERIAL REF SIPS PANEL DRAWINGS FOR ANCHORAGE TO CONCRETE STEM WALL PREMOLDED JOINT MATERIAL TYP REF ARCH (STEM WALL AND SLAB MAY BE POURED MONOLITHICALLY AT CONTRACTOR'S OPTION) REF SUPPLIER FOR SIPS WALL PANEL REF SCHED GRID CONCRETE SLAB ON GRADE, REF FDN PLAN REF WALL FTG SCHED FOR TRANS REINF REF WALL FTG SCHED FOR LONG REINF REF FDN PLAN TOF EL NOTE: 1. BOTTOM OF FOUNDATION SHALL BE PLACED PER GEOTECHNICAL RECOMMENDATIONS. FOR ADDITIONAL INFO, REF GENERAL NOTES ON SHEET S0.1. REF FDN PLAN FF EL #4 CONT AT 12" OC MAX (2 MIN) FACE OF SIPS PANEL = EDGE OF SLAB CL R 3" TYP 3" CLR RE F S C H E D (2) #4 HORIZ CONT REF ARCH FOR FINISH MATERIAL REF SIPS PANEL DRAWINGS FOR ANCHORAGE TO CONCRETE STEM WALL REF SUPPLIER FOR SIPS WALL PANEL REF SCHED 8"EQ EQ CONTRACTOR'S OPTION #4 DOWELS AT 18" OC WITH 90 DEGREE HOOK INTO FTG; ALTERNATE DIRECTION 1 1 EDGE OF CONT STEM WALL BEYOND CONCRETE SLAB ON GRADE, REF FDN PLAN CONC PAVING/FINISH GRADE, REF CIVIL REF 1-S2.1 FOR CONC STEM WALL REINF #5 AT 12" OC MAX SPACING AS REQUIRED (2 MIN)REF SCHED NOTE: 1. FOR ADDITIONAL INFORMATION NOT SHOWN, REFER TO DETAIL 1-S2.1. 1 RE F S C H E D 3" C L R CONCRETE STEM WALL MATCHING SIPS PANEL THICKNESS (REF SIPS PANEL SUPPLIER) 4" MIN TYP 3" CLR REF PLAN REF ARCH FOR FINISH MATERIAL REF SUPPLIER FOR SIPS WALL PANEL FACE OF SIPS PANEL = FACE OF CONC STEM WALL FACE OF SIPS PANEL = FACE OF CONC STEM WALL REF FDN PLAN TOF EL EDGE OF CONT FTG BEYOND #4 PEDESTAL HAIRPIN DOWELS AT 18" OC. CONCRETE SLAB ON GRADE, REF FDN PLAN CONC PAVING/FINISH GRADE, REF CIVIL #5 AT 12" OC MAX SPACING AS REQUIRED (2 MIN)REF SCHED NOTE: 1. FOR ADDITIONAL INFORMATION NOT SHOWN, REFER TO DETAIL 1-S2.1. 1 RE F S C H E D 3" C L R 4" MIN TYP 3" CLR REF PLAN REF ARCH FOR FINISH MATERIAL REF SUPPLIER FOR SIPS WALL PANEL FACE OF SIPS PANEL = EDGE OF SLAB FACE OF SIPS PANEL = EDGE OF SLAB REF FDN PLAN TOF EL EDGE OF CONT FTG BEYOND #4 PEDESTAL HAIRPIN DOWELS AT 18" OC. CONTRACTOR'S OPTION REF 1-S2.1 FOR CONC TURNDOWN REINF EDGE OF SLAB TURNDOWN BEYOND CONCRETE SLAB TURNDOWN MATCHING SIPS PANEL THICKNESS (REF SIPS PANEL SUPPLIER) REF FDN PLAN FF EL (2) #4 CONT, REF 1-S2.1 CONC SLAB ON GRADE, REF FDN PLAN #4 DOWELS x 3'-0" AT 12" OC AT DOOR OPENINGS ONLY (MIN 3 EACH LOCATION) CONC PAVING, REF CIVIL 1' - 0" NOTE: 1. FOR ADDITIONAL INFORMATION NOT SHOWN, REFER TO DETAIL 1-S2.1. GRID 8" #4 HORIZ CONT AT 12" OC MAX (2 MIN)REF 1-S2.1 FOR CONC STEM WALL FACE OF CONC BELOW REF FDN PLAN TOF EL RE F S C H E D REF SCHED REF 1-S2.1 FOR CONT FTG REF 1-S2.1 FOR FOOTING DOWELS REF FDN PLAN FF EL (2) #4 CONT, REF 1-S2.1 CONC SLAB ON GRADE, REF FDN PLAN #4 DOWELS x 3'-0" AT 12" OC AT DOOR OPENINGS ONLY (MIN 3 EACH LOCATION) CONC PAVING, REF CIVIL 1' - 0" NOTE: 1. FOR ADDITIONAL INFORMATION NOT SHOWN, REFER TO DETAIL 1-S2.1. GRID #4 HORIZ CONT AT 12" OC MAX (2 MIN) FACE OF CONC BELOW REF FDN PLAN TOF EL RE F S C H E D REF SCHED REF 1-S2.1 FOR CONT FTG REF 1-S2.1 FOR FOOTING DOWELS CONTRACTOR'S OPTION GRID REF FDN PLAN TOF EL REF FDN PLAN FF ELCONCRETE STEM WALL MATCHING SIPS PANEL THICKNESS (REF SIPS PANEL SUPPLIER) FACE OF SIPS PANEL = FACE OF CONC STEM WALL REF ARCH FOR FINISH MATERIAL REF SIPS PANEL DRAWINGS FOR ANCHORAGE TO CONCRETE STEM WALL REF SUPPLIER FOR SIPS WALL PANEL NOTE: 1. FOR ADDITIONAL INFORMATION NOT SHOWN, REFER TO DETAIL 1-S2.1. ADDITIONAL #4 PEDESTAL HAIRPIN DOWELS AT 18" OC CONTRACTOR'S OPTION GRID #4 PEDESTAL HAIRPIN DOWELS AT 18" OC CONCRETE SLAB ON GRADE, REF FDN PLAN REF FDN PLAN TOF EL REF FDN PLAN FF EL CONCRETE SLAB TURNDOWN MATCHING SIPS PANEL THICKNESS (REF SIPS PANEL SUPPLIER) FACE OF SIPS PANEL = EDGE OF SLAB REF ARCH FOR FINISH MATERIAL REF SUPPLIER FOR SIPS WALL PANEL REF SIPS PANEL DRAWINGS FOR ANCHORAGE TO CONCRETE STEM WALL #4 PEDESTAL HAIRPIN DOWELS AT 18" OC CONC PAVING/FINISH GRADE, REF CIVIL REF 1-S2.1 FOR CONC TURNDOWN REINF NOTE: 1. FOR ADDITIONAL INFORMATION NOT SHOWN, REFER TO DETAIL 1-S2.1. ADDITIONAL #4 CONT AT 12" O.C. MAX (2 MIN) JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S2.1 PROJECT NUMBER: 24212 FOUNDATION DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB 3/4" = 1'@0" 1TYPICAL SIPS PANEL WALL SECTION 3/4" = 1'@0" 2WALL SECTION AT PILASTER 3/4" = 1'@0" 3CONCRETE SLAB AT OPENING 3/4" = 1'@0" 4WALL SECTION AT PILASTER OTP 11/12/24 11/12/24 MIN 1' - 6" DIA 1 1 CL R 3" MIN 1' - 9" CONT ARCH REF CL POST 2' - 6 " M I N REF ARCH FOR SLAB THICKNESS AND REINFORCING #4 DOWELS AT 12" OC 2'-0" #4 T&B WITH MATCHING CORNER BARS TRASH ENCLOSURE FOUNDATION WALL SECTION REF ARCH FOR WALL DETAILS GATE BOLLARD FOUNDATION DETAIL 3' - 0 " M I N MIN 3" CL FOUNDATION AND POST REF ARCH FOR GATE DETAILS REF SIPS VENDOR FOR WOOD POST AT HOLD-DOWN REF SIPS VENDOR FOR CONT SILL PLATE REF 1-S2.1 FOR CONCRETE STEM WALL OR SLAB TURNDOWN REF FDN SCHEDULE FOR CONTINUOUS WALL FOOTING REF SIPS VENDOR FOR SIMPSON HOLD-DOWN AND SIMPSON PAB ANCHOR BOLT DIAMETER STEP FOOTING DOWN AS REQUIRED ANCHOR 10". CLR 3" SECTION VIEW ISOMETRIC VIEW REF SIPS VENDOR FOR WOOD POST AT HOLD-DOWN REF SIPS VENDOR FOR SIMPSON HOLD-DOWN AND SIMPSON PAB ANCHOR BOLT DIAMETER R E F F D N P L A N F F E L / T O S T E M W A L L E L R E F F D N P L A N T O F E L 10 " AN C H O R E M B E D M E N T REF 1-S2.1 FOR CONC STEM WALL OR SLAB TURNDOWN FF EL / TO STEM WALL EL REF FDN PLAN TOF EL REF FDN PLAN REF FDN SCHEDULE FOR CONTINUOUS WALL FOOTING REF SIPS VENDOR FOR CONTINUOUS SILL PLATE 8"8"1 1 EM B E D M E N T CONCRETE WALL, REF FDN PLAN AND DETAILS #4 HORIZ CORNER BARS AT 12" OC 2'-0" 2' - 0 " V-JOINT REVEAL BOTH SIDES OF WALL REF SECTIONS FOR WALL REINFORCEMENT 2x4 KEY AT CL WALL #4x3'-0" HORIZ AT 12" OC, CENTER ON JOINT TERMINATE EVERY OTHER HORIZONTAL BAR 3" FROM JOINT, TOP MOST BARS IN WALL TO BE CONTINUOUS V-JOINT BOTH SIDES AT 20'-0" OC MAX SPACING 1 1/2" MAX MIN 3/4" MIN 3/4" OFFSET 2" MAX JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S2.2 PROJECT NUMBER: 24212 FOUNDATION DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB 3/4" = 1'@0" 5TRASH ENCLOSURE FOUNDATION DETAILS 3/4" = 1'@0" 1SHEAR WALL HOLD@DOWN 3/4" = 1'@0" 2CONCRETE WALL CORNER DETAIL 1" = 1'@0" 3CONCRETE WALL CONSTRUCTION JOINT 1" = 1'@0" 4CONCRETE WALL CONTROL JOINT OTP 11/12/24 11/12/24 TOP CHORDS OF PREFABRICATED WOOD TRUSS FOR SPACING REF SIP DRAWINGS 2x4 WITH SIMPSON LU24 HANGER EACH END (2) 2x4 WITH SIMPSON LUS24-2 HANGER EACH END; IF REQD, PREFAB WOOD TRUSS GIRDER WITH HANGER PER MFR PREFAB WOOD TRUSS WITH HANGER PER MFR (IF REQD) DOUBLE TRUSS, REF FRAMING PLAN NOTES: 1. ATTACH SIP ROOF PANEL AT OPENING WITH #14 PANEL SCREW 12" OC. 2. * FOR OPENING DIMENSION, REF MECH AND ARCH DRAWINGS 4' - 0 " M A X * (2) 2x4 WITH SIMPSON LUS24-2 HANGER EACH END; IF REQD, PREFAB WOOD TRUSS GIRDER WITH HANGER PER MFR DESIGN TRUSS FOR 110 LB POINT LOAD AT PERPENDICULAR SOFFIT LOCATIONS, TYP 2x6 BLOCKING AT 16" OC WITH (3) 16d TOE NAILS EA END 362S162-43 MTL STUDS AT 16" OC NOTE: 1. LOCATE SOFFITS PER ARCH DRAWINGS. 2. REF ARCH FOR ADDITIONAL INFORMATION 362T125-43 CONT TRACK WITH #10-16 SCREWS EA FLANGE AT EA STUD BO STUD EL REF ARCH MIN 16 GA CLIP ANGLE WITH (4) #10-16 SCREWS EA STUD AND (3) 1/4" DIA SCREWS TO BLOCKING, TYP PREFAB WOOD TRUSS, REF PLAN 2x4 BLOCKING AT 16" OC WITH (3) 16d TOE NAILS EA END 2x4 DIAGONAL BRACING EVERY OTHER TRUSS SPACE WITH (2) 16d TOE NAILS EA END DESIGN TRUSS FOR 40 PLF LOAD AT PARALLEL SOFFIT LOCATIONS, TYP 2x6 BLOCKING AT 16" OC WITH (3) 16d TOE NAILS EA END 362S162-43 MTL STUDS AT 16" OC NOTE: 1. LOCATE SOFFITS PER ARCH DRAWINGS. 2. REF ARCH FOR ADDITIONAL INFORMATION 362T125-43 CONT TRACK WITH #10-16 SCREWS EA FLANGE AT EA STUD BO STUD EL REF ARCH (4) #10 WOOD SCREWS EA STUD, TYP PREFAB WOOD TRUSS, REF PLAN 2x4 DIAGONAL BRACING AT 16" OC WITH (2) 16d TOE NAILS EA END 2x4 BLOCKING AT 16" OC WITH (3) 16d TOE NAILS EA END MECHANICAL UNIT, REF MECHANICAL; ATTACH TO CURB PER MANUFACTURER REQUIREMENTS RTU CURB, REF ARCH; ATTACH TO TRUSS/BLOCKING WITH #14 PANEL SCREWS AT 12" OC, TYP SIP ROOF PANEL (2) 2x6 BLOCKING WITH SIMPSON LUS 26-2 HANGER EA END AT ALL (4) SIDES OF RTU CURB (NOT REQUIRED IF CURB IS ALIGNED WITH TRUSS) PREFAB WOOD TRUSS, REF PLAN (2) 2x6 BLOCKING WITH SIMPSON LUS 26-2 HANGER AT 48" OC MAX; LOCATE AT TRUSS PANEL POINT DUCT OPENING BEYOND, REF 1-S3.0 FOR FRAMING 4x4 WOOD SLEEPERS CONT PER ARCH SIP ROOF PANEL CONDENSING UNIT, REF MECHANICAL, ATTACH TO SLEEPER PER MANUFATURER REQUIREMENTS #14 PANEL SCREW AT EACH 2x4, TYP PREFAB WOOD TRUSS, REF PLAN 2x4 AT 48" OC MAX WITH LU24 SIMPSON HANGER EA END; LOCATE AT TRUSS PANEL POINT JOHNSTON B A URKHOLDER SSOCIATES c o n s u l t i n g s t r u c t u r a l e n g i n e e r s 930 C 816.421.4200 · · K C MO ENTRAL ANSAS ITY,64105 WWW.JBAENGR.COM REVISIONS ISSUE DATE COPYRIGHT NOTICE This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site named herein, and cannot be reproduced in any manner without the express written permission from the professional CIRCLE K STORES, INC. PROFESSIONAL SEAL PROJECT NAME PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROTOCYCLE # R3.4.1 05/16/23 JBA PROJECT #24226 S3.0 PROJECT NUMBER: 24212 ROOF FRAMING DETAILS CIRCLE K STORES, INC. NWC YELM AV & KILLION RD YELM, WA 98597 YELM, WA JBA JNF KSH BCB NTS 1TYP FRAMING AROUND SMALL ROOF OPNG 3/4" = 1'B0" 5SOFFIT DETAIL PERPENDICULAR TO TRUSS 3/4" = 1'B0" 4SOFFIT DETAIL PARALLEL TO TRUSS 3/4" = 1'B0" 3RTU SUPPORT NTS 2CONDENSING UNIT SUPPORT OTP 11/12/24 11/12/24