Mechanical Plans - APPROVED1.MOUNT THERMOSTATS 48" ABOVE FINISH FLOOR. 2.DUCTWORK AND EQUIPMENT SHOWN IS DIAGRAMMATIC. COORDINATE AND ROUTE DUCTWORK TO MEET JOB REQUIREMENTS. LOCATION OF EQUIPMENT MUST BE COORDINATED WITH ALL DISCIPLINES BEFORE FINAL LOCATIONS ARE SELECTED. WEIGHTS OF EQUIPMENT MUST BE VERIFIED AND COORDINATED WITH STRUCTURAL SYSTEMS BEFORE EQUIPMENT CAN BE INSTALLED AT JOBSITE. 3.SPACE ALLOCATED FOR MECHANICAL AND OTHER WORK ABOVE THE SUSPENDED CEILINGS IS CRITICAL. LIGHT FIXTURES AND AIR DIFFUSERS HAVE BEEN LOCATED TO ACHIEVE A DEFINITE ARCHITECTURAL EFFECT AND MAY NOT BE CHANGED WITHOUT THE CONSENT OF THE ARCHITECT. BECOME FAMILIAR WITH THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS PRIOR TO FABRICATING AND INSTALLING ANY MATERIALS. HANG DUCTWORK AS CLOSE AS POSSIBLE TO THE STRUCTURE ABOVE, UNLESSINDICATED OTHERWISE. 4.LOCATE CEILING DIFFUSERS, REGISTERS AND GRILLES AS SHOWN ON THE ARCHITECTURAL REFLECTED CEILING PLANS. 5.FLEXIBLE RUNOUTS TO BE SAME SIZE AS DIFFUSER NECK. REFER TO DIFFUSER SCHEDULE AND A MAX. OF 8'- 0" IN LENGTH . MECHANICAL SPECIFICATIONSMECHANICAL CONTRACTOR NOTES DUCTWORK: 1.GALVANIZED STEEL IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS. 2.ELBOWS; SQUARE TYPE WITH TURNING VANES. 3.BRANCH TAKE-OFF FROM MAIN DUCTS; SPLITTER DAMPERS OR EXTERNALLY ADJUSTABLE EXTRACTORS. 4.FLEXIBLE DUCTWORK; INSULATED WITH 1" THICK FIBERGLASS WITH A VAPOR BARRIER; FLAME SPREAD RATING NOT OVER 25 AND DEVELOPED SMOKE RATING NOT OVER 50. CONNECT WITH CIRCUMFERENTIAL COMPRESSION CLAMPS OF STAINLESS STEEL OR NYLON. 5.SPIN-IN FITTINGS; MANUFACTURED ROUND GALVANIZED COLLAR DESIGNED TO SCREW INTO A MATING HOLE, WITH AN AIR EXTRACTOR AND MANUAL BALANCING DAMPER. THERMAFLEX, WIREMOLD, CLEVAFLEX. 6.ALL DUCTWORK CONNECTION SHALL BE SEAL. THIS INCLUDE BUT NOT LIMITED TO WATER PROOF AND VAPOR PROOF SEAL. GC SHALL GUARANTEE DUCTWORK INSTALLATION WONT GENERATE CONDENSATION TO THE SPACE. INSULATION: 1.INSULATION, INCLUDING FACING, JACKETS, AND ADHESIVE USED TO ADHERE THE FACING OR JACKET; NOT EXCEEDING A FLAME SPREAD OF 25, NOR A SMOKE DEVELOPED RATING OF 50AS, TESTED IN ACCORDANCE WITH ASTM E84 AND UL LISTED. 2.SUPPLY DUCTWORK; 2" THICK BLANKET TYPE FIBERGLASS INSULATION WITH A MINIMUM DENSITY OF 1 LB/CU. FT., AND FACTORY APPLIED FLAME RETARDANT FOIL-REINFORCED KRAFT FACING. WRAP INSULATION ON THE DUCTWORK WITH ALL CIRCUMFERENTIAL JOINTS BUTTED AND LONGITUDINAL JOINTS OVERLAPPED A MINIMUM OF 2". ADHERE INSULATION WITH 4" STRIPS OF INSULATION BONDING ADHESIVE AT 8" CENTERS. FIBERGLASS SERIES ED- 100 OR EQUAL. AIR DISTRIBUTION: 1.AIR DISTRIBUTION DEVICES; AMCA CERTIFIED PERFORMANCE RATINGS, NOISE LEVELS NOT TO EXCEED NC- 35. STEEL ITEMS SHALL BE FINISHED WITH FACTORY APPLIED WHITE BAKED ENAMEL. CARNES, TITUS, TUTTLE & BAILEY, KRUGER, ANEMOSTAT. 2.MANUFACTURER'S NAMES AND CATALOG NUMBERS INDICATES MATERIALS ACCEPTED BY THE ENGINEER. SUBMIT SUBSTITUTES OF EQUIVALENT MATERIALS OF- SIMILAR QUALITY, THE SAME 3.OR BETTER WITH RESPECT TO STYLE AND FUNCTION, FOR REVIEW AND ACCEPTANCE, STATE PROPOSED EXCEPTIONS TO REQUIREMENTS CLEARLY IN ONE PLACE, INCLUDING REQUIRED RELATED CHANGES TO BUILDING SYSTEMS, OPERATING PROCEDURES, AND MAINTENANCE FUNCTIONS. HVAC EQUIPMENT: 1.EXISTING 2 TON UNIT - ROOFTOP EQUIPMENT- TO BE FIELD VERIFIED AS TO LOCATION. 2.GC SHALL PROVIDE NEW SUPPLY AND RETURN DUCTWORK AS SHOWN. REUSE SUPPLY AND RETURN DUCTWORK WHEN POSSIBLE. CODES: 1.THE ENTIRE INSTALLATION SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE, MECHANICAL CODE AND ALL LOCAL ADOPTED AMENDMENTS AND ORDINANCES. REFER TO THE ARCHITECTURAL COVER SHEET CODE REFERENCE FOR REFERENCED CODES. LAY-IN HVAC SUPPLY DIFFUSER. CONNECT TO TRUNK LINE ABOVE PER CODE. 24X24 TITUS OMNI OR EQ. THERMASTAT - MOUNT AT 48" A.F.F. FLEX DUCT RUN OUT TO DIFFUSER/RETURN LAY-IN HVAC SUPPLY DIFFUSER. CONNECT TO TRUNK LINE ABOVE PER CODE. 24X24 TITUS OMNI OR EQ. 14x12 14x12 RTU 200 CFM 8" Ø 200 CFM 8" Ø 200 CFM 8" Ø 200 CFM 8" Ø 10"Ø10"Ø 10x10 OUT OF SCOPE OF WORK 20240036 10.07.2024 ARCHITECTURE PLANNING PROGRAMMING INTERIORS AIA NCARB c - COPYRIGHT -2024 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H A B C D E F G H CO N F I D E N T I A L : T H E S E D O C U M E N T S A R E PR O P R I E T A R Y A N D T H E S O L E P R O P E R T Y O F FI N A N C I A L S U P E R M A R K E T S , I N C . & M A R K E T CO N T R A C T O R S , I N C . N O P A R T O F T H I S IN F O R M A T I O N S H A L L B E U S E D , C O P I E D , O R DI S T R I B U T E D B Y A N Y P E R S O N I N C L U D I N G TH E C L I E N T W I T H O U T T H E P R I O R W R I T T E N CO N S E N T O F F I N A N C I A L S U P E R M A R K E T S , IN C . A N D M A R K E T C O N T R A C T O R S , I N C . FI N A N C I A L S U P E R M A R K E T S , I N C . FS I S R PRINTING & REVISIONS BC A - S T U D I O S A R C H I T E C T S Ga i n e s v i l l e - A t l a n t a 41 0 B R A D F O R D S T R E E T N W GA I N E S V I L L E , G E O R G I A 3 0 5 0 1 1 W E S T C O U R T S Q A U R E SU I T E 5 4 0 DE C A T U R , G E O R G I A 3 0 3 0 3 47 0 - 4 8 0 - 5 5 6 0 CONSTRUCTION DOCUMENTS SA F E W A Y # 1 6 1 9 11 0 9 E Y E L M A V E YE L M , W A 9 8 5 9 7 A N E W S U P E R M A R K E T B A N K F O R : 45456 P R O F E S IONA L R E GIS T E R E D E N G INEER STA O F T E H N G JUS T I N R.H A R D Y WAS I T O N S M1.0 INSULATED FLEX DUCT SUPPORT STRAP CEILING T-BAR FRAME (TYP.)- PROVIDE METAL HANGER (TYP.) INSULATED SUPPLY ADAPTER/PLENUM PLANS LOCKING QUADRANT FOR SIZE SEE SPIN-IN FITTING WITH VOLUME DAMPER METAL DUCT DIFFUSER / RETURN DETAIL DEVICE NECK SIZE TO MATCH RUN OUT AIR SCOOP FRAME AT GYP INSTALLTIONS STEEL WIRE TO STRUCTURE (SUPPLY ONLY) MFG ACCESSORY FLAT OVAL CONNECTION HARD TRANSITION FLEX DUCT (3') ADJUST DIRECTIOAN BLADES FOR SIDEWAYS DISCHARGE SEE PLANS FOR AIRFLOW DIRECTION. SLOT DIFFUSER DETAIL HARD DUCT TO MAIN WITH SPIN-IN, SCOOP AND DAMPER LINED PLENUM MECHANICAL PLAN