Indigo, Yelm Plumbing Permit Set 12.01.24758(
1257+
INDIGO, YELM - PLUMBING PERMIT SET 12/01/24
VICINITY MAP
PROJECT LOCATION
':5()
67$))
/281*(
&20081,7<
68,7(
)$0,/<
68,7(
.,'6
68,7(
32&7
5(675220
5(675220
6725$*(
&$5(
7($0
+$//
+$//
+$//
+$//
87,/,7<
5220
+($/,1*
68,7(
&/$5,7<
68,7(
-$1,725
&/($1
6833/<
62,/('
6833/<
&23<
)2&86
/281*(
5(*,675$7,21
$
N
POINT OF CONNECTION TO
EXISTING 4" SANITARY SEWER
POINT OF CONNECTION TO
EXISTING 4"SANITAY SEWER
(E) 4" FCO
POINT OF CONNECTION TO
EXISTING 4" SANITARY SEWER
POINT OF CONNECTION TO
EXISTING 4"SANITARY SEWER
2" SS
(E) 4"
WCO
(E) 4" FS
(E) 4" FS
EXISTING 4" SANITARY SEWER
P-3
P-2P-2P-2
P-5
P-5
P-9 3" WCO
P-4
P-1
P-1
P-1 P-8(A)
P-8(B)
2" SS
4" SS
4" WCO
2" WCO
P-7
2" WCO
2" WCO
2" WCO
2" WCO
2" SANITARY SEWER
2" SANITARY SEWER
2" SS
2" SS
2" SS
2" SS
3" SANITARY SEWER
3" SS
3" SS
2"
S
A
N
I
T
A
R
Y
S
E
W
E
R
(E
)
4
"
S
A
N
I
T
A
R
Y
S
E
W
E
R
2"
S
S
2"
S
S
4"
S
S
(E
)
4
"
S
A
N
I
T
A
R
Y
S
E
W
E
R
(
E
)
4
"
S
A
N
I
T
A
R
Y
S
E
W
E
R
(E) 4" SS
(E) 4" SS
2" SS2" SS
SANITARY SEWER FOUNDATION FLOOR PLAN
DW-1
':5()
67$))
/281*(
&20081,7<
68,7(
)$0,/<
68,7(
.,'6
68,7(
32&7
5(675220
5(675220
6725$*(
&$5(
7($0
+$//
+$//
+$//
+$//
87,/,7<
5220
+($/,1*
68,7(
&/$5,7<
68,7(
-$1,725
&/($1
6833/<
62,/('
6833/<
&23<
)2&86
/281*(
5(*,675$7,21
$
N
2" SV2" SV
2" SV
3" SANITARY VENT
THROUGH ROOF
2" SV
2" SV
2" SV
2" SV
2" SANITARY VENT
2" SV 2" SV 2" SANTARY VENT
2" SV
(E) 4" SANITARY VENT
THROUGH ROOF
POINT OF CONNECTION TO
EXISTING 2" SANITARY VENT
(E) 2" SV
POINT OF CONNECTION TO
EXISTING 2" SANITARY VENT
2" SV
2"
S
V
2"
S
V
2"
S
V
2"
S
V
2"
S
V
2"
S
V
2"
S
V
2"
S
V
(E
)
2
"
S
V
2"
S
V
P-4
P-1
P-5 P-9
P-5
P-8(B)P-1
P-1 P-8(A)
P-7
P-2 P-2 P-2
P-3
SANITARY VENT FLOOR PLAN
DW-1
':5()
67$))
/281*(
&20081,7<
68,7(
)$0,/<
68,7(
.,'6
68,7(
32&7
5(675220
5(675220
6725$*(
&$5(
7($0
+$//
+$//
+$//
+$//
87,/,7<
5220
+($/,1*
68,7(
&/$5,7<
68,7(
-$1,725
&/($1
6833/<
62,/('
6833/<
&23<
)2&86
/281*(
5(*,675$7,21
$
N
zz
z
z
zz ET-1
CP-1
WH-1
EXISTING 2" DOMESTIC COLD
WATER SERVICE & REDUCED
PRESSUE BACKFLOW ASSEMBLY
POINT OF CONNECTION TO
EXISTING 2" DOMESTIC
COLD WATER SERVICE
WITH INDEPENDENT SUITE
ISOLATION VALVE.
1-1/2"
1/2 DCW
1" DCW
1" DCW
1" DCW3/4" DCW
3/4" DCW3/4" DCW1/2" CW
1" DHW 1" DHW 1" DHW 1" DHW
1" DHW
1/2" DHW
1" DHW
1" DHW 1" DHW
1" DHW1" DHW
3/4" DHW 3/4" DHW
3/4" DHW
3/4" DHW
3/4" DCW
3/4" DCW 1" DCW 1" DCW
3/4" DCW1/2" DCW
1"
D
H
W
1"
D
H
W
1"
D
H
W
1/
2
"
D
H
W
1/
2
"
D
C
W
1"
D
C
W
3/
4
"
D
C
W
1/
2
"
D
C
W
1/
2
"
D
C
W
1/
2
"
H
W
1/
2
"
H
W
1/
2
"
C
W
1/
2
"
H
W
1/
2
"
H
W
1/
2
"
C
W
1/
2
"
C
W
1/
2
"
H
W
1"
D
C
W
1"
D
H
W
1-
1
/
2
"
D
C
W
1
"
D
C
W
3/
4
"
D
H
W
3/
4
"
D
H
W
1/
2
"
D
H
W
R
1"
D
C
W
1/
2
"
C
W
P-7 P-2
P-2 P-2
P-8(A)
P-8(B)
P-1
P-1
TMV-1
TMV-1
P-5
P-4
P-1 P-5 P-9
P-3
DOMESTIC WATER FLOOR PLAN
(E) 2" DCW
(E
)
2
"
D
C
W
(E
)
2
"
D
C
W
1/2" DCW 1/2" DCW
CM-1
BFP-1
IM-1 DW-1