Issued for Rev.Date
Drawing No.
Scale
Drawn By
Project No.
DRAWING TITLE
Date
Froula Alarm Systems, Inc.
861 Industry Drive
Tukwila, WA 98188
206-575-1962
20
2
4
205272-124-2975
12/5/2024
JCN
AS NOTED
FA0.00 - SHT. 1 OF 4
COVER SHEET
1ISSUED FOR PERMIT 12/5/24
IN
D
I
G
O
M
U
L
T
I
C
A
R
E
T
I
-
Y
E
L
M
RU
S
H
C
O
M
M
E
R
C
I
A
L
C
O
N
S
T
R
U
C
T
I
O
N
93
7
W
.
Y
E
L
M
A
V
E
.
,
Y
E
L
M
,
W
A
9
8
5
9
7
FIRE ALARM SYSTEM EQUIPMENT LEGEND
SYMBOL QTY PART #MANUFACTURER DESCRIPTION MOUNTING BACK BOX
1 EXISTING 6700 SILENT KNIGHT
EXISTING INTELLIGENT
FIRE ALARM SYSTEM
CONTROL PANEL
MAX 66” AFF TO CENTER OF DOOR OF
PANEL, MINIMUM 36” OPENING
CLEARANCE BETWEEN MULTIPLE
PANELS IN ROOMS
INCLUDED
1 NEW PSN-106 POTTER BOOSTER POWER SUPPLY
MAX 66” AFF TO CENTER OF DOOR OF
PANEL, MINIMUM 36” OPENING
CLEARANCE BETWEEN MULTIPLE
PANELS IN ROOMS
INCLUDED
6 NEW PC2WLED SYSTEM SENSOR LED HORN STROBE -
CEILING MOUNT - WHITE CEILING-MOUNTED 4" SQUARE
13 NEW SCWLED SYSTEM SENSOR LED STROBE - CEILING
MOUNT - WHITE CEILING-MOUNTED 4" SQUARE
FACP
BPS
INDIGO MULTICARE TI - YELM
RUSH COMMERCIAL CONSTRUCTION
937 W. YELM AVE., YELM, WA 98597
PROJECT SITE MAP
PROJECT FIRE ALARM SYSTEM NOTES:
1.ALL WORK TO CONFORM TO 2019 ED. NFPA 72, 2021 IBC, INCLUDING WA STATE
AMENDMENTS, AND 2020 NFPA 70 (NEC) STANDARDS.
2.SYSTEM DESIGN BASED ON INTERNATIONAL FIRE CODE 2021 AND/OR LOCAL
AUTHORITY HAVING JURISDICTION CODES AND/OR ADDENDUM CRITERIA.
3.WALL MOUNT NOTIFICATION DEVICES TO BE MOUNTED 84" AFF, OR 6" BELOW
CEILING (WHICHEVER DISTANCE IS LOWER), TO STROBE LENS OR SOUNDER.
4.PULL STATIONS TO BE MOUNTED:
4.1.NO GREATER THAN 48" AFF TO DEVICE HANDLE.
4.2.WITHIN 5' OF THE DOOR.
5.FIRE ALARM CONTROL PANEL TO BE ON UN-SWITCHED, DEDICATED 120VAC
CIRCUIT WITH CIRCUIT BREAKER LOCK ON.
6.WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT
WILL BE CONTAINED WITHIN CONDUIT UNLESS IN OCCUPANCY WHERE
CONDUIT IS REQUIRED THROUGH OUT.
7.SMOKE AND HEAT DETECTORS TO BE INSTALLED:
7.1.12" MAX FROM SIDEWALLS
7.2.MORE THAN 36" FROM ANY HVAC DIFFUSER
7.3.NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING
7.4.AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING
8.ALL JUNCTION BOXES, MUD RINGS, AND BOX COVERS TO BE PAINTED RED
(INSIDE AND OUT).
9.EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING
STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD.
INPUT/OUTPUT MATRIX
PROJECT CONTACTS
SALESPERSON:ANDREW EARLE
861 INDUSTRY DRIVE
TUKWILA, WA 98188
PHONE: (206) 920-4321
PROJECT DESIGNER: CHRIS NORRIS
PROJECT DESIGNER
861 INDUSTRY DRIVE
TUKWILA, WA 98188
PHONE: (425) 420-8786
PROJECT MANAGER: BILL HUGGINS
PROJECT MANAGER
861 INDUSTRY DRIVE
TUKWILA, WA 98188
PHONE: (206) 472-3867
NOTE: THIS IS A TYPICAL MATRIX DESIGN. NOT ALL ASPECTS MAY BE APPLICABLE TO SPECIFIC JOB.
N
FIRE ALARM SYSTEM WIRE LEGEND
SYMBOL DESCRIPTION COLOR CODING CIRCUIT APPLICATION NOTES
14 AWG 2 CONDUCTOR BARE COPPER,
TWISTED, NON-SHIELDED PLENUM FIRE
ALARM, FPLP (UL)
WINDY CITY P/N 767963 RED
JACKET w/ YELLOW STRIPE NAC POWER CIRCUIT
NOTES: **STRIPES ARE NOT REQUIRED. HOWEVER IT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION.
1- NOT USED
2- FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS
3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, IE: PLENUM, RISER, UNDERGROUND, ETC.
4- NOT USED
5- THIS CABLE MUST BE INSTALLED IN A CONTINUOUS PATH POINT-TO-POINT. ABSOLUTLEY NO SPLICES ARE ALLOWED.
6- THIS IS A SPECIFIC CABLE, NO ALTERNATES ARE ALLOWED
B
CODE INFORMATION
FIRE ALARM AUTHORITY HAVING JURISDICTION
THURSTON COUNTY FIRE MARSHAL
FIRE ALARM DESIGNER OF RECORD
HOWARD WILLIAMSON
NICET LEVEL IV, FIRE ALARM SYSTEMS
NICET ID: 82289
PROJECT CODE REFERENCES:
·THURSTON COUNTY FIRE CODE (2021ED)
·INTERNATIONAL BUILDING CODE (2021ED), INC. WASH. STATE AMENDMENTS
·INTERNATIONAL FIRE CODE (2021ED), INC. WASH. STATE AND THURSTON
COUNTY AMENDMENTS
·INTERNATIONAL MECHANICAL CODE (2021ED)
·NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72, 2019ED)
·NATIONAL ELECTRICAL CODE (NFPA 70, 2020ED)
PROJECT DESCRIPTION
THE INTENT OF THIS DESIGN IS TO PROVIDE AND ADD TO EXISTING FIRE ALARM
SYSTEM THAT ACTIVATES THE OCCUPANT NOTIFICATION SYSTEM IN THIS TENANT
IMPROVEMENT DURING A FIRE EMERGENCY.
COMMUNICATION METHOD
COMMUNICATION OF ALL TROUBLE, SUPERVISORY, AND ALARM SIGNALS SHALL BE
PROVIDED AND INSTALLED WITH A COMMUNICATOR/COMMUNICATION MEANS
ACCEPTABLE BY THE AHJ, VIA THE FACP.
CO
P
Y
R
I
G
H
T
C
FR
O
U
L
A
A
L
A
R
M
S
Y
S
T
E
M
S
(
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
)
Issued for Rev.Date
Drawing No.
Scale
Drawn By
Project No.
DRAWING TITLE
Date
Froula Alarm Systems, Inc.
861 Industry Drive
Tukwila, WA 98188
206-575-1962
20
2
4
205272-124-2975
12/5/2024
JCN
AS NOTED
FA0.01 - SHT. 2 OF 4
TYPICAL DEVICE
WIRING DETAILS
1ISSUED FOR SUBMITTAL 12/5/24
IN
D
I
G
O
M
U
L
T
I
C
A
R
E
T
I
-
Y
E
L
M
RU
S
H
C
O
M
M
E
R
C
I
A
L
C
O
N
S
T
R
U
C
T
I
O
N
93
7
W
.
Y
E
L
M
A
V
E
.
,
Y
E
L
M
,
W
A
9
8
5
9
7
-++
MOUNTING PLATE
WALL & CEILING HORN-STROBE
ST
R
I
P
G
U
A
G
E
-++
MOUNTING PLATE
WALL & CEILING HORN-STROBE
ST
R
I
P
G
U
A
G
E
-++
MOUNTING PLATE
WALL & CEILING HORN-STROBE
ST
R
I
P
G
U
A
G
E
5.1k
HORN-STROBE MOUNTING PLATE
BACKBOX & MOUNTING ISOMETRICS
HORN-STROBE MOUNTING PLATE
4"x4"2.25
"
DEEP BO
X
(-
)
(
+
)
(
+
)
N
NAC4 B-
NAC4 B+
NAC3 B-
NAC3 B+
NAC2 B-
NAC2 B+
NAC1 B-
NAC1 B+
NO
NC
CO
M
TB2
TB3
NA
C
4
A-
A+
NA
C
3
NA
C
2
NA
C
1
TB2
A-
A+
A-
A+
A-
A+
NAC5 B-
NAC5 B+
NAC6 B-
NAC6 B+
NAC OUTPUT #2
NAC OUTPUT #3
NAC OUTPUT #4
NAC OUTPUT #1
DB
BPS NAC POWER SUPPLY
A HORN-STROBE MOUNTING PLATE
NNNN
HORN-STROBE MOUNTING PLATE
NN
FROM NAC
SOURCE
STROBE CONTROL & OUTPUTS
FROM BPS NAC POWER SUPPLY
Scale: NTS
COMBINATION HORN-STROBE
VIA BPS NAC POWER SUPPLY6
CO
P
Y
R
I
G
H
T
C
FR
O
U
L
A
A
L
A
R
M
S
Y
S
T
E
M
S
(
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
)
Issued for Rev.Date
Drawing No.
Scale
Drawn By
Project No.
DRAWING TITLE
Date
Froula Alarm Systems, Inc.
861 Industry Drive
Tukwila, WA 98188
206-575-1962
20
2
4
205272-124-2975
12/5/2024
JCN
AS NOTED
FA0.02 - SHT. 3 OF 4
TYPICAL DEVICE
MOUNTING
REQUIREMENTS
1ISSUED FOR PERMIT 12/5/24
IN
D
I
G
O
M
U
L
T
I
C
A
R
E
T
I
-
Y
E
L
M
RU
S
H
C
O
M
M
E
R
C
I
A
L
C
O
N
S
T
R
U
C
T
I
O
N
93
7
W
.
Y
E
L
M
A
V
E
.
,
Y
E
L
M
,
W
A
9
8
5
9
7
36" MINIMUM4" MINIMUM
EXIT
CONDUIT
INSTALL PER NATIONAL
ELECTRIC CODE
MOUNT ON AN
APPROVED BOX
SMOKE/HEAT
DETECTOR
AIR SUPPLY DIFFUSER
OR RETURN AIR OPENING
MOUNT AUDIBLE & VISUAL
DEVICES ON APPROVED BOXES
GRAPHIC
ANNUNCIATOR
HORN/STROBE
CONTROL
PANEL
STROBE
MANUAL PULL
STATION
HORN
SMOKE/HEAT
DETECTOR
FINISHED FLOOR
HINGED SIDE
6" MIN
4" MIN
12" MAX
80" MIN
DISTANCE
TO BOTTOM
OF DEVICE
96" MAX
DISTANCE
TO TOP OF
DEVICE
60" MAX
44"
(42" MIN,
48" MAX)
66"
54"
Scale: 1" = 1'-0"
TYPICAL DEVICE MOUNTING REQUIREMENTS1
LOUNGE
100
COPY
102
COMMUNITY
SUITE
103
FAMILY
SUITE
104
KIDS
SUITE
105
UTILITY
ROOM
126
HEALING
SUITE
106
CLARITY
SUITE
108
JANITOR
118
IT
119
CLEAN
SUPPLY
120
SOILED
SUPPLY
121
STAFF
LOUNGE
123
REGISTRATION
100A
RESTROOM
114
RESTROOM
113
POCT
115
STORAGE
116
CARE
TEAM
110
HALL
109
HALL
117
HALL
125
HALL
107
WHEELCHAIR
ALCOVE
111
CRASH
CART
112
DINAMAPS
124
FOCUS
101
FACPBPS
N1:07
15cd
N1:01
15cd
N1:02
15cd
N1:03
15cd
N1:04
15cdN1:05
15cd
N1:06
30cd
5.1kΩ
N2:03
15cd
N2:05
15cd
N2:06
15cd
N2:01
15cd
N2:04
15cd
N2:02
15cd
5.1kΩ
N3:01
75cd
N3:05
15cd
N3:04
15cd
N3:02
15cd
N3:06
15cd
N3:03
15cd
5.1kΩ
BB
B
B
BB
BB
B
B
B
B
B
B
B
B
B
B
B
CO
P
Y
R
I
G
H
T
C
FR
O
U
L
A
A
L
A
R
M
S
Y
S
T
E
M
S
(
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
)
Issued for Rev.Date
Drawing No.
Scale
Drawn By
Project No.
DRAWING TITLE
Date
Froula Alarm Systems, Inc.
861 Industry Drive
Tukwila, WA 98188
206-575-1962
20
2
4
205272-124-2975
12/5/2024
JCN
AS NOTED
FA2.01 - SHT. 4 OF 4
FIRE ALARM
SYSTEM PLAN
1ISSUED FOR PERMIT 12/5/24
IN
D
I
G
O
M
U
L
T
I
C
A
R
E
T
I
-
Y
E
L
M
RU
S
H
C
O
M
M
E
R
C
I
A
L
C
O
N
S
T
R
U
C
T
I
O
N
93
7
W
.
Y
E
L
M
A
V
E
.
,
Y
E
L
M
,
W
A
9
8
5
9
7
Scale: 1/4" = 1'-0"
FIRE ALARM SYSTEM PLAN1 1/4"=1'-0"
04'4 8
N
Scale: NTS
RISER DIAGRAM2
SCOPE OF WORK:
1.UPDATE FIRE ALARM SYSTEM FOR TENANT
IMPROVEMENT TO ACCOMMODATE NEW FLOOR
PLAN.
GENERAL NOTES:
1.DEVICES SHOWN IN BLACK ARE EXISTING;
DEVICES SHOWN IN RED OR BLUE ARE NEW;
DEVICES SHOWN IN ORANGE ARE RELOCATED;
ALL DEVICES SHOWN ARE INTEGRATED INTO
EXISTING FIRE ALARM SYSTEM.
5.1kΩ
5.1kΩ
N2:01
15cd
N2:02
15cd
B
B
N1:01
15cdFACP
N1:02
15cd
N1:03
15cd
N1:04
15cd
N2:03
15cd
N2:04
15cd
N2:05
15cd
5.1kΩ
N3:01
75cd
N3:02
15cd
B N3:03
15cd
N3:04
15cd
N3:05
15cd
BPS
N1:05
15cd
N1:06
30cd
N1:07
15cd
N2:06
15cd
N3:06
15cd
EXISTING FACP