Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans 2190AB 2024-11-01
; WEATHER RESISTANT BARRIER OVER SHEATHING OR SUBSTRATE FINISH SIDING GSM TRIM FLASHING WITH 5" MIN. VERTICAL LEO HORIZONTAL WOOD TRIM HOR IZ. TRIM 061T STUDS N.T.S. REAR ELEVATION 1 /411= I 1-011 12 RIGHT ELEVATION /411= 1 1_011 2x6 EXTERIOR WALL 1/16, PLY OR OSB SHEATHING, TYP. SIDING PER ELEVATIONS OVER VAPOR BARRIER, PRE -FINISHED CONTINUOUS - SWEETMETAL FLASHING, TYP. COMP. ROOFING OVER VAPOR BARRIER ATOP 1/16' PLY OR 055 SHEATHING, TYP. IA IL TRUSS OR RAFTER PER PLAN \ " ROOF TO WALL. FLASHING DOTAL N.T.S. 12 LEFT ELEVATION /'4n- 11_Ou :S COMP ROOF 5/4x8 BARGE B4B SIDING CONT. GUTTER 6" EXP. HORIZ. SIDING ?ADE TO SLOPE AWAY FROM FOUNDATION A MIN. OF 6" WITHIN THE FIRST 10' z V r M--1 M W V. a ♦♦♦ y � oN0 � III W Q z1.4 h N ♦ O �a E 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2M-2190-2L Date: 10-24-24 0 �n ' a� 0 ' N U_ 2'-11' 6/Ox4l& XO 4/Ox4/6 XO 1 EG 1 SS O O O O1 x N 0 M. BATH 50 CE�d0 O �e 0 I r 8' CLG. It I ' i'-i 0 I 76 MASTER EDROOM � 3 S'X I -r VAULTS CLG. w 110V I 0 I I n_56 I t I MIN. I-ISPF 110 Al G 1 t 1 1 MAX BTU/HR 8 CLG. 1 ' xx xxx 6'-5'-1' ------------- 6 2X6 WALL O O Lw. PANASONIC TUB/ BATH �� XHAUST FAN _ `t SHWR 8' CLG. R UAL I t50 � UTIL.022X30 8' CLG, mA.A. 0 0 110V 0° O 0 u 5EDROOM-2 x 8' CLG. 61 w z lu ®B.P. 2'-8' I n4 110V I � WIG S.D. 8' CLG. BEDROOM-3 WIG 8' CLG. 8' CLG. I EGRESS 6/Ox44 XOX cn S C ON I LOFT 0-I u � 1 1 M� 8' CLG. p _1z - 4� QI � ? 1 Om -I 3: tll 110V © cA O S.D. 5EDROOM-4 ®6' CLG. P. EGRESS Px4/1'o XOX 0 U r O U_ e tt N N W O ' O Q m 4'-6' 5'-10' 5'-10' op 01 4- 13'-0' I1'-8' 30' -0' UPPER 1=1.00iZ PLAN 1/4"=1'-O" INTERIOR STAIRWAY ILLUMINATION PER SEC R303.1 I INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING: WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN I FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. i - FLOOR LINEI ABOVE- - - - - - - ------ - PANTRY S' CLG. DINING 9' CLG. O � x �z x El N GREAT ROOM 9' CLG. DIRECT VENT NATURAL GAS J METAL FIREPLACE INSTALL PER MFR SPECS. PROVIDE V SQ IN. OUTSIDE AIR a - KITCHEN 0 S' CLG. 100 EF �'-11' 3'-11j' 3'-6j' 3'-i' 4'-41 4 r REFER o O s i 771 0 RANGE - - `" 0 2 6 WALL 8/ HIGH G.O. 2X6 WALL 0 LEC. HEAT PUMP No' MIN. SOLID CORE 0o WATER HEATER 1..1{ SELF CLOSING DOOR/Z 0 VEHICLE BARRIER WOOD,STEEL �HWH OR 20 MIN. RACED P%ND 6 NOTES PROVIDE EXPANSION TANK 9 LG. 3 'X36' MI NDING ® / - PROVIDE SEISMIC STRAPPING 4 U, 0 L / - TPRV TO TERMINATE TO r OPT./ �\ W OPT. DR OUTSIDE F X24�A. PILOT 4 CONTROLS TO BE 16' fi r �4 MIN. OFF FLOOR - PER ASH RAE SO-A-60 - - - - NAT GAS WATER HTR. W/ MIN. EF - - - X OF 0.62 WE V - ELECTRIC WATER HTR W/ MIN. EFLU 0 OF 0.S3 ° H L q 0 HEAT DETECTOR Z U_ 01 INTERCONNECTED O B PER 31423 ° 2 GAR GARAGE G %5 Q LINE ABV.= CD USE 1/2' GWB ON ALL WARM AND -SLR - _ - STRUCTURAL WALLS. (1) LAYER 5/8' TYPE `" 'X' ON CEILINGS. WRAP ALL EXPOSED POSTS ENTRY AND BEAMS IN 1/2' GW15 9 CLG. Z" NO DUCT OPENINGS UP 1IR - IN GARAGE. DUCTS THROUGH CLG OR WALL COMMON TO HOUSE, SG MIN. 26 GAGE STEEL. 0 1/6x6 0 FX 16/0 x 8/0 O.H. I DOOR 16'-3" R.O. L- - - - - - - - - - - - - - - -- BLUE 14 AWG TRACER I COVERED LANDING AT 'EXIT' DOOR WIRE REQUIRED AT NON- NOT TO BE LOWER THAN FORCH 9 METAL WATER SERVICE IB INCHES FROM TOP OF 0 PIPING PER UPC 604.10.1 THRESHOLD. (R3113.1) CONC. 0 0 UTILITY ROOM NOTES/MAKE UP Al PER IRC G243S I. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 Ft OF THE EXHAUST DUCT CONNECTION PER G243S.IB. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243SB. = 100 SQ INCH TRANSFER GRILL 2'-0' ISI-0' I1'-0' 30'-0' MA I N FLOOR PLAN /4"=1'-O° WHOLE HOUSE VENTILATION: •REFER TO SHEET N-2 TABLE 1505.43(1) 4 1505.43(2) FOR FAN SIZING AND RUN TIMES FURNACE TO HAVE A DUCT FOR OUTSIDE AIR, MOTORIZED DAMPER WITH TIMER AND CONTROLS ARE TO BE ADDED FOR THE REQUIRED FRESH AIR EXCHANGE. 2X STUD WALL / CONC WALL 2-1/4' 0 X 5' LAG SCREWS STUD WALL 2-3/8' 0 X 5' BOLTS W/ SIM SON VGC ADHESIVE • CONC WALL 16 GA STEEL STRAPPING ArpUD WATER HEATER W TI W N THE UPPER t LOWER ONE-THIRD OF THE APPL. 4 A MIN. OF 4' FROM CONTROLS HOLD WATER HEATER TIGHT TO CsWB * BACK FLEXIBLE WATER CONNECTIONS 2X4 LEDGER PRESSURE TREATED *CONC WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER < LOWER ONE-THIRD OF THE APPL. 4 A MIN. OF 4' FROM CONTROLS ANCHOR WH TO BASE - BASE TO FLOOR NO SCALE WATER HEATER SUPPORT GENERAL NOTES: 1. ALL WORK TO BE IN CONFORMANCE WITH 2O21 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE DRAIN. 6. SHOWERHEADS 4 KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.11011 FLOW. 1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET TO BE SAFETY GLASS. 6. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS S. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE 0 IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. ° =SMOKE ALARM -CARBON MONOXIDE COMBO. C 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR 4 OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2021 IRC 4 WA. STATE AMENDMENTS SEC R315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC R403B3. 12. ALL DUCTS 4 EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303.52. 14. GAS PIPING IS t0 BE PROTECTED PER G2415.1. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC 4 CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE 4 WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 1-1. DRYER DUCT SPECIFIED LENGTH PER SEC M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 16. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2021 WSEC TABLE R402.4.1.1. IS. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) MAIN FLOOR: 54a 0. PT. UPPrER r-LOOR: 1542 50. PT. TOTAL: 21CIO 0. PT. GARAGE: 5rt 1 SQ . PT. FRONT PORCH: 128 50. PT. Z 0 00 ® O 0-4(D V 1 Ch M 00 � �, •� z a ♦♦♦ E yN E ORN A gym z o �� C M h N� O �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. I Plan No: L2M-2190-2L Date: Ifs-24-24 0j, ill 1 N BI 0 Cq 0 03 4" N BEDROOM-2 S' CLG. W z 110V [� S.D. BEDROOM-3 6' CLG. EGRESS 6/0x4/6 XOX 13' -0' cn 110V [� S.D. BEDROOM-3 6' CLG. EGRESS 6/0x4/6 XOX 13' -0' cn G I I- LOFT QI u m S' CLG. i 9 -0 I I A 411 I It I � tll 0 t '0 cn S.D. 8' I 5EDROOM-4 ®� P 8' CLG. 9 XOX UPPER r-LOOR PLAID 1/4n= 1 i-Ou INTERIOR STAIRWAY ILLUMINATION PER SEC R3031 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN I FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. 76 A r 4" r 9 m �r °O U u @ 0 ' 0 �4 On N 0 ua LL m O ' O %0 d U1 UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 I. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G2439.IB. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243c3B. E ::1 100 SQ INCH TRANSFER GRILL PANTRY V CLG. DINING 9' CLG. X El 24'-61' GREAT ROOM V CLG. DIRECT VENT NATURAL GAS METAL FIREPLACE INSTALL PER MFR SPECS. PROVIDE 6' SQ IN OUTSIDE AIR 7 KITCHEN 100 CFM E.F. i -11 3 -� 4 4 REFER O 0 s cq E `1' 0o ELEC i' 13ke' MIN. SOLID CORE 2X& WALLS/0 HIGH G.O. 2X6 WALL I, I WATER HEATER SELF CLOSING DOOR VEHICLE BARRIER WOOD,STEEL �HWH NOTES OR 20 MIN. RATED 6 P%�fl I PROVIDE EXPANSION TANK 9LG. 1�M1 ® / - PROVIDE SEISMIC STRAPPING 0 _ OPT. - TPRV TO TERMINATE TO DR / OUTSIDE 5 �_ F X24-C.A. - PILOT E CONTROLS TO BE 18' MIN. OFF FLOOR (:�} - PER ASH RAE 90-A-80 - - - - - NAT GAS WATER HTR. W/ MIN. EF OF 0.62 (K y - ELECTRIC WATER HTR W/ MIN. EF - - - OF 0.93 o H Z HEAT DETECTOR INTERCONNECTED PER 3142.3 °0 C 2 GAR 6ARA E USE 1/2' GWB ON ALL WARM AND FLR LINE ABV. 3: _ _ - STRUCTURAL WALLS. (1) LAYER 5/6' TYPE - 'X' ON CEILINGS. WRAP ALL EXPOSED POSTS ENTRY AND BEAMS IN 1/2' GWB V CLG. NO DUCT OPENINGS UP 1-IR m IN GARAGE. DUCTS THROUGH CLG OR WALL COMMON TO HOUSE, SIG MIN. 26 GAGE STEEL. AV- 1/6x6(0 FX 16/0 x 8/0 O.H. DOOR 16'-3' RO. L- - - - - - - - - - - - - - - I COVERED RGH IL NC. I- I I I - - - - - - - - - - 9'-6' 9'-6'01 MAID FLOOR PLAID I/41I= I'-OII WHOLE HOUSE VENTILATION: •REFER TO SHEET N-2 TABLE 1505.430) 4 1505.43(2) FOR FAN SIZING AND RUN TIMES FURNACE TO HAVE A DUCT FOR OUTSIDE AIR, MOTORIZED DAMPER WITH TIMER AND CONTROLS ARE TO BE ADDED FOR THE REQUIRED FRESH AIR EXCHANGE. in g g 2X STUD WALL / CONIC WALL 2-1/4' 0 X 5' LAG SCREWS ® STUD WALL 2-3/8' 0 X 5' BOLTS W/ SIM SON VGC ADHESIVE a CONIC WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER t LOWER ONE-THIRD OF THE APPL. < A MIN. OF 4' FROM CONTROLS HOLD WATER HEATER TIGHT TO GWB s BACK FLEXIBLE WATER CONNECTIONS 2X4 LEDGER PRESSURE TREATED ® GONG WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER t LOWER ONE-THIRD OF THE APPL. < A MIN. OF 4' FROM CONTROLS ANCHOR WH TO BASE - BASE TO FLOOR NO SCALE WATER HEATER SUPPORT GENERAL NOTES: I. ALL WORK TO BE IN CONFORMANCE WITH 2O21 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE DRAIN. 6. SHOWERHEADS 4 KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.F`.M FLOW. -1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET TO BE SAFETY GLASS. 8. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS S. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING A BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY 'n FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. ° =SMOKE ALARM -CARBON MONOXIDE COMBO. C 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR d OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2021 IRC E WA. STATE AMENDMENTS SEC R315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC R403B3. 12. ALL DUCTS t EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303B2. 14. GAS PIPING IS TO BE PROTECTED PER G2415.1. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC E CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE E WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 11. DRYER DUCT SPECIFIED LENGTH PER SEC M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 16. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2021 WSEC TABLE R402.4.1.1. IS. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) MAIN FLOOR: 54a 50. PT. UPPrER r-LOOR: 1548 50. PT. TOTAL: 2 I C16 50. PT. GARAGE: 5rt 1 SQ . PT. FRONT PORCH: 128 50. PT. Z 00 0 0-4 T� M AV •U z a ♦♦♦ E yN E00 VR -Okn •�• F A gym oo yn z00 Co 16. xh N� O �a r- 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: 1 L2M-2190-2L Date: 10-24-24 2*1