Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans 2382AB 2024-11-20
; ; 2' MI 6/0x /0 XO 4/Ox4/ XO EGRESS SG 4'X3' 48 _ SOAKING o TUB , CLG. I I _ A - N 1 ul aD 1 0) aD iQ ) I�w 5 G MSTR. BATH STER -BED-Room O 8 cLG. OPTIONAL S.D. 0 50111 0 A VAULTED CLG.NU O O cq (A IVA /PAIR 2'-5j' 8'-4j' / 24' NICHE O d) 6 11 II II B.P. L FT/OFT. BEn 5 It -"" r CLG. 110V i7 x a L- LL- W 0 ® I . ° B.P. I I r SD. It 0 4'-2' 1 �9' I rF _3'-' -2j' itl m ` � BE�7R \ OM-2 I `q e - X x w S C o I II \ G. 1Co 2X6 WALL 0 110VPANASONIC WHISPER QUIET CONTINUOUS CA EXHAUST EXHAUST FAN OR EQUAL ` 0' 150 CFM m �' W.HF. C U m O ,11 cr LL O 0 0� N 61F W C*4 ;4 Z O - r O 4 m A OFEN TO BELOW SHELF 4/0x2YO FX u • Q - • `ioo�.00000��ao� �o��oo�o�.�oo��oo�000000� - I _ --- - - - - - - - - - N N LIN ® © ®B.P. B.P. 5'-10' 2'-2' 31- '-9 ' V-2j' 110V 10 110V 5EDROOM-5 S.D. O 8' CLG. EGRESS Dx4TFXO BEDROOM 4 8' CLG. EGRESS 6/Ox4/e XO 3'-0' 2'-6j' 13'-2' 2X STUD WALL / CONC WALL 2-1/4' 40 X 5' LAG SCREWS ® STUD WALL 2-3/8' fp X W BOLTS W/ SIMPSON VGC ADHESIVE ® CONC WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER E LOWER ONE-THIRD OF THE APPL. t A MIN. OF 4' FROM CONTROLS HOLD WATER HEATER TIGHT To GWB ® 5AcK FLEXIBLE WATER CONNECTIONS 2X4 LEDGER PRESSURE TREATED ® CONC WALL I6 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER 4 LOWER ONE-THIRD OF THE APPL. t A MIN. OF 4' FROM CONTROLS ANCHOR WH TO BASE - BASE TO FLOOR NO SCALE WATER HEATER SUPPORT UPPER FLOOR PLAN 1/4 UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 I. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G2439.1B. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET 18 DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR. MEANS PER G2439B. E - = 100 SQ INCH TRANSFER GRILL C4 VENTILATION CRAWL SPACE VENTILATION TOTAL NET FREE AREA REQ'D 106-1/300 = 3.56 SQ. FT. PROVIDE SCREENED VENTS FOR VENTILATION �o VENTS fiREQ'U GENERAL NOTES: 1. ALL WORK t0 BE IN CONFOIRS IANCE WITH 2O21 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES t0 OUTSIDE. 4. PROVIDE FIRE BLOCKING At ALL PLUMBING AND MECHANICAL PENEtR4TIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE DRAIN. 6. SHOWERHEADS 4 KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.15 G.P.M. FLOW. ALL OCHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.P.M FLOW. 1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET TO BE SAFETY GLASS. 8. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' Or - FLOOR TO BE SAFETY GLASS S. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS t0 BE INSTALLED NOT LESS THAN 3 Ft. HORIZONTALLY FROM A BATHROOM THAT GONtA INS A BATHTUB OR SHOWER ALARMS t0 BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. ° =SMOKE ALARM -CARBON MONOXIDE COMBO. C 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR d OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2021 IRC E WA. STATE AMENDMENTS SEC R315. 11. INSULATE ALL WATER PIPES t0 MINIMUM R-3 PER WSEC R403B3. 12. ALL DUCTS t EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED t0 A MINIMUM OF R-8 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED t0 BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303.52. 14. GAS PIPING IS TO BE PROTECTED PER G2415.1. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC E CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE E WITH LABEL AFFIXED t0 CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 11. DRYER DUCT SPECIFIED LENGTH PER SEC M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. I& CAVITIES WITHIN COMERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2021 WSEC TABLE R402.4.1.1. IS. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) INTERIOR STAIRWAY ILLUMINATION PER SEC R3031 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING 18 PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303B IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. WHOLE HOUSE VENTILATION: REFER TO SHEET N-2 TABLE 1505.430) E 1505.43(2) FOR FAN SIZING AND RUN TIMES 8'-2r �'_3' T T - - - - - - - - - - - - - - - - COVERED FO CH I I C014C. II I I 6/0x8/0 SGD Sis. i N M N LANDING At 'EXIT' DOOR NOT TO BE LOWER THAN IB INCHES FROM TOP OF THRESHOLD. (R3113.1) VENT THROUGH ROOF OR CONNECT 1 1/2' TO OTHER VENTS - g DRAIN BOARD �T -- - - - I I NEAREST - 1 1/2' PARTITION VERTICAL FIXTUVENT 1/4' PER FOOT VERTICAL 2' GRADE FIXTURE DRAIN NO FIXTURES UPSTREAM c FOOT VE' C.O. a b A,B, AND C ARE Y-BRANCH FITTINGS PLUMBING LOOP N.T.9 11Ox610 XO DINING ROOM 9' CLG. IL N x 0 BLUE 18 AWG TRACER WIRE REQUIRED AT NON- METAL WATER SERVICE PIPING PER UPC 604.9. 1/4"=1'-oil MAIN r-LOOR: 106""t 50. r-T. UPPER r-LOOR: 1515 50. fT. TOTAL: 2582 50. IT. 6ARA&r= : 384 50. r-T . r-RONT PORCH: ml(� 50. fT. REAR PORCH: m78 50. fT . COPYRIGHT 2010 Landmark Design Inc. CLEAN OUT ALL RIGHTS RESERVED HORIZONTAL DRAIN tA � T� M a) 00 S A 204 PQ °U z ♦♦♦ E yN E � -ON A gym oo ynin Co z00 16. N� 0 �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: L2M-2382-2R Date: 11-18-24 2 • 2' MI A N �t m LLZ s O N 0� W N;5 K1 r �1 ' O T- O 4 El .1O\8\\OO - coni OPEN TO BELOW SHELF nx4VO FX �11 - • `�oo�a00000��ao� �o��.00�.o..�oo��.00�.000000� - I _ 00 � 0 • • 110V 110V 5EDROOM-3 S.O 8' CLG. EGRESS 0 6/Ox XO ��. ❑ BEDROOM 4 8' CLG. E EGRESS 10x4/I6 XOX 3'-0' 2'-6 ' g�_1' 5'-9 ' 6'--I' J. 11'-4' 13'-2' 30'-0' 2X STUD WALL / CONC WALL 2-1/4' 40 X 5' LAG SCREWS ® STUD WALL 2-3/8' 0 X 5' BOLTS W/ SIMPSON VGC ADHESIVE ® CONC WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER E LOWER ONE-THIRD OF THE APPL. t A MIN. OF 4' FROM CONTROLS HOLD WATER HEATER TIGHT TO GWB ® BACK FLEXIBLE WATER CONNECTIONS 2X4 LEDGER PRESSURE TREATED ® CONC WALL I6 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER 4 LOWER ONE-THIRD OF THE APPL. t A MIN. OF 4' FROM CONTROLS ANCHOR WH TO BASE - BASE TO FLOOR NO SCALE WATER HEATER SUPPORT UPPER FLOOR PLAN 1/4 UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 I. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G2439.1B. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET 18 DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR. MEANS PER G2439B. E - = 100 SQ INCH TRANSFER GRILL VENTILATION CRAWL SPACE VENTILATION TOTAL NET FREE AREA REQ'D 106-1/300 = 3.56 SQ. FT. PROVIDE SCREENED VENTS FOR VENTILATION �o VENTS fiREQ'U GENERAL NOTES: I. ALL WORK TO BE IN CONFORMANCE WITH 2O21 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE DRAIN. 6. SHOWERHEADS E KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.-I5 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.P- I FLOW. -1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET TO BE SAFETY GLASS. 8. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS S. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. =SMOKE ALARM -CARBON MONOXIDE COMBO. C.M. 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR E OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2021 IRC t WA. STATE AMENDMENTS SEC R315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC R403B3. 12. ALL DUCTS E EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303.52. 14. GAS PIPING IS TO BE PROTECTED PER G24151. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER. WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC 4 CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHER-STRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 WR TIMER, READILY ACCESSIBLE 4 WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 1-1. DRYER DUCT SPECIFIED LENGTH PER SEC M502AB.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502AS.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 18. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2021 WSEC TABLE R402A.1.1. IS. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) INTERIOR STAIRWAY ILLUMINATION PER SEC R3031 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH 18 NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING 18 PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. WHOLE HOUSE VENTILATION - *REFER TO SHEET N-2 TABLE 1505.430) E 1505A3(2) FOR FAN SIZING AND RUN TIMES 8'-2r �'_3' T - - - - - - - - - - - - - COVER n e I I PORCH II CONC II 8/0x8/0 SGD Sis. N M 0 �4 N LANDING AT 'EXIT' DOOR NOT TO BE LOWER THAN IB INCHES FROM TOP OF THRESHOLD. (R3113.1) I BUILT-IN I I I/Oxgi/O XO DINING ROOM 9' CLG. RV gHf4 HEAT DETECTOR - NAT GAS WATER HTR. W/ M OF 0.62 - ELECTRIC WATER WTR W/ MIN. EF /0 3'- 4 1'-9' INTERCONNECTED OF 0.93 PER 31423 GARAGE U0 E 1/2' GWB ON ALL WARM AND ® ® STRUC URAL WALLS. (1) LAYER 5/8' TYPE 'X' ON CEILINGS. WRAP ALL EXPOSED POSTS AND BEAMS IN 1/2' GWB 0 NO DUCT OPENINGS IN GARAGE. DUCTS THROUGH CLG OR WALL COMMON TO HOUSE, MIN. 26 GAGE STEEL. 16/0 x 8/0 O.H. DOOR 16'-3' R.O. -10 19' -0' MAIN FLOOR FLAN VENT THROUGH ROOF OR CONNECT 1 1/2' TO OTHER VENTS - g DRAIN BOARD I I NEAREST - 1 1/2' PARTITION VERTICAL TURE VNT 1/4' PER FOOT VERTICAL 2' GRADE FIXTURE DRAIN NO FIXTURES UPSTREAM c FOOT VE C.O. a b A,B, AND C ARE Y-BRANCH FITTINGS PLUMBING LOOP N.T.9 0 0 N 14 A 0 N 4" r BLUE 18 AWG TRACER WIRE REQUIRED AT NON- METAL WATER SERVICE PIPING PER UPC 604.9. 1/411= I'-O" MAIN r-LOOR: 106"1 50. r-T. UPPER 1L.00R: 1515 50. PT. TOTAL.: 2582 50. r-T. GRG B84 SQ . �T . r-RONT PORCH: "Tcl 50. �T. REAR PORCH: l8 SQ. FT. COPYRIGHT 2010 Landmark Design Inc. CLEAN OUT ALL RIGHTS RESERVED HORIZONTAL DRAIN z v T� M °U z CD ♦♦♦ E yN E 10* 2-n A gym CD CD yn z! h Nti O �a r- 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. 1 Plan No: L2M-2382-2R Date: 11-18-24 2*1