Loading...
Tommy Moore Stamped Permit Pack1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV1 Cover Sheet Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e APPLICABLE CODESAHJ UTILITY COMPANY SHEET INDEX City of Yelm WA Puget Sound Energy *2023 NATIONAL ELECTRIC CODE (NEC) *2021 INTERNATIONAL BUILDING CODE (IBC) *2021 INTERNATIONAL RESIDENTIAL CODE (IRC), 2021 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES Enphase RESIDENTIAL ROOFTOP SOLAR PERMIT PACKAGE Tommy Moore 9224 Conine St SE Yelm, Washington 98597 2532673566 PV1 PV2 PV3 PV4 PV5 PV6 PV7 PV8 SS COVER SHEET SITE PLAN ROOF PLAN STRUCTURAL ELECTRICAL 3-LINE ELECTRICAL CALCULATIONS LABELS PLACARD SPEC SHEETS SCOPE OF WORK INSTALLATION OF ROOFTOP MOUNTED PHOTOVOLTAIC SOLAR SYSTEM 4.300 kW DC 3.250 kW AC NEW PV SYSTEM INFORMATION DC SYSTEM SIZE: AC SYSTEM SIZE: MODULE TYPE: INVERTER TYPE: 4.3 kW DC 3.25 kW AC (10) Silfab Solar SIL-430 QD (10) Enphase IQ8M-72-M-US DESIGN CRITERIA WIND SPEED: WIND EXPOSURE FACTOR: RISK CATEGORY: GROUND SNOW LOAD: ROOF SNOW LOAD: SEISMIC DESIGN CATEGORY: TYPICAL STRUCTURAL INFORMATION 110 C II   D ROOF MATERIAL: SHEATHING: FRAMING: RACKING: ROOF ATTACHMENT: TOTAL ATTACHMENTS: Comp Shingle OSB Manufactured Truss UNIRAC SFM INFINITY UNIRAC SFM BUTYL 19 WEATHER STATION DATA TACOMA NARROWS 28°C -4°C WEATHER STATION: HIGH TEMP 2% AVG: EXTREME MINIMUM TEMP: GENERAL NOTES TOTAL PV DC SYSTEM SIZE TOTAL PV AC SYSTEM SIZE 13.974 kW ACCEC-AC SYSTEM SIZE: PV Installation Professional Cecil Lopeman #042013-75 Sealed For Existing Roof & Attachment Only 1/15/25 Digitally signed by John Calvert Date: 2025.01.15 06:45:02 -07'00' DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC MSPACCB M SUB N W S E 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV2 Site Plan Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e SITE PLAN SCALE: 1/8" = 1'-0" UTILITY METER ROOF TOP JUNCTION BOX MAIN SERVICE PANEL SUBPANEL LEGEND AC DISCONNECT PV PRODUCTION METER COMBINER BOX BREAKER ENCLOSURE ESS - BATTERY ESS - CONTROLLER GENERATOR ATS PANEL UTILITY METER CT CABINET TRENCH OR OVERHEAD PROPERTY LINE REMOTE POWER OFF SWITCH FIRE SETBACK HATCH COMPASSPV SYSTEM SPECIFICATIONS PV MODULE: (10) Silfab Solar SIL-430 QD, POWER RATING: 430 W INVERTER: (10) Enphase IQ8M-72-M-US, POWER RATING: 325 W NEW PV SYSTEM NEW PV SYSTEM INFORMATIONM MSP SUB BE AC PV CB ATSCT BAT ESC RPO MICROINVERTERDC AC ICONS WITH DOTTED OUTLINE INDICATE INTERIOR LOCATIONINVERTERINV VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. FR O N T O F H O M E 92 2 4 C o n i n e S t S E Sealed For Existing Roof & Attachment Only 1/15/25 DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC MSPACCB M SUB N W S E 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV3 Roof Plan Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e UTILITY METER ROOF TOP JUNCTION BOX MAIN SERVICE PANEL SUBPANEL LEGEND AC DISCONNECT PV PRODUCTION METER COMBINER BOX BREAKER ENCLOSURE ESS - BATTERY ESS - CONTROLLER GENERATOR ATS PANEL UTILITY METER CT CABINET TRENCH OR OVERHEAD PROPERTY LINE REMOTE POWER OFF SWITCH FIRE SETBACK HATCH COMPASSPV SYSTEM SPECIFICATIONS PV MODULE: (10) Silfab Solar SIL-430 QD, POWER RATING: 430 W INVERTER: (10) Enphase IQ8M-72-M-US, POWER RATING: 325 W NEW PV SYSTEM NEW PV SYSTEM INFORMATIONM MSP SUB BE AC PV CB ATSCT BAT ESC RPO MICROINVERTERDC AC ICONS WITH DOTTED OUTLINE INDICATE INTERIOR LOCATIONINVERTERINV ROOF PLAN SCALE: 1/8" = 1'-0" VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. FR O N T O F H O M E MP1 MODULE QTY: 10 AZIMUTH: 180 PITCH: 23 TSRF: 97 AREA: 680 ft² 1'-6" 1'-6" 3' UNDERGROUND SERVICE LINE POINT OF INTERCONNECTION 3' Sealed For Existing Roof & Attachment Only 1/15/25 FRAMING DETAIL SCALE: 1/2" = 1'-0"1 EXISTING FRAMINGROOF MATERIAL NOT SHOWN FOR CLARITY *THIS DETAIL IS NOT MEANT TO BE AN EXACT REPRESENTATION OF FRAMING OR PV MODULE LAYOUT EXTERIOR WALL PV MODULES SHALL NOT EXTEND ABOVE ROOF RIDGE LINE PV MODULE PV MODULES SHALL NOT EXTEND MORE THAN 6 INCHES FROM THE PLANE OF THE ROOF ATTACHMENT DETAIL SCALE: 1-1/2" = 1'-0"2 PV MODULE UNIRAC SFM INFINITY 2" MICRORAIL UNIRAC SFM INFINITY 6.5" SPLICE MAX CANTILEVER PER TABLE ABOVE (C) FRAMING SPACING PER TABLE ABOVE (2) #14-14 x 3" SCREW W/ EPDM WASHER ATTACHMENT TYPE: Unirac SFM Butyl 1 3 4" MIN. EMBEDMENT ATTACHMENT SPACING PER TABLE ABOVE PORTRAITLANDSCAPE ATTACHMENT PATTERN SCALE: 1/4" = 1'-0"3 *ATTACHMENT PATTERN SHOULD BE STAGGERED UNLESS OTHERWISE NOTED IN ENGINEERING LETTER FOLLOW ATTACHMENT SPACING IN TABLE ABOVE RIDGE EAVE MP1 MP2 MP3 MP4 MP5 MP6 MP7 MP8 PANEL COUNT ROOF MATERIAL SHEATHING TYPE FRAMING TYPE FRAMING SIZE AND SPACING RACKING TYPE ATTACHMENT TYPE MAXIMUM ATTACHMENT SPACING (S) MAXIMUM CANTILEVER (C) CEILING JOIST/ PURLINS SIZE AND SPACING AZIMUTH (DEG) PITCH (DEG) TSRF (%) AREA (ft²) TOTAL PV ATTACHMENTS TOTAL PV ARRAY WEIGHT (lbs) POINT LOAD (lbs/att.) PRIMARY ROOF AREA (ft²) PRIMARY PV ARRAY AREA (ft²) PRIMARY ROOF COVERAGE (%) DISTRIBUTED LOAD (psf) MP9 MP10 SECONDARY ROOF AREA (ft²) SECONDARY PV ARRAY AREA (ft²) SECONDARY ROOF COVERAGE (%) * IF APPLICABLE 10 180 23 97 680 Comp Shingle OSB Manufactured Truss 2x4 @ 24 in OC 2x4 @ 12 in OC UNIRAC SFM INFINITY UNIRAC SFM BUTYL 72''L / 48''P 24''L / 16''P 0 0 0 0 0 0 0 0 0 463 19 24.4 209.99 2009.8 2.2 10.45 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV4 Structural Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e NOTES Sealed For Existing Roof & Attachment Only 1/15/25 PV CIRCUIT 1 PRIMARY PV COMBINER BOX N G G (10) PV MODULES & MICROINVERTERS PRIMARY STRUCTURE A B CD E 1 2GATEWAY (N) 20A 10 MODULES 1 PV ARRAY 1 315A EQUIPMENT DESCRIPTIONS PV MODULE: Silfab Solar SIL-430 QD, 430 W DC, UL 1703 / UL 61730 COMPLIANTA MICROINVERTER: ENPHASE IQ8M-72-M-US, 325 W AC (0.325 kW), 1 PHASE, UL 1741 COMPLIANTB ROOFTOP JUNCTION BOX: EZ SOLAR JB-1.2 JUNCTION BOXC JUNCTION BOX: PVC 4 X 4 JUNCTION BOXD E F G H I J K L PV COMBINER BOX: ENPHASE COMBINER 5 (X-IQ-AM1-240-5) M N O P Q R EQUIPMENT NOTES 1 2 3 4 5 6 7 8 9 10 11 12 S T LEGEND (E) SPD EXISTING (N)NEW (EL)EXISTING LOADS (RL)RELOCATED LOADS (PV)PV BREAKER (FIB)FACTORY INSTALLED BREAKER SURGE PROTECTIVE DEVICE INTERCONNECTION NOTES Utility Meter Number: 173435145 Load Side Breaker in MSP, Exterior POI SQUARE-D SAFTEY SWITCH 30A, 2P, 240VAC, NON-FUSIBLE (DU221RB) VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. UNDERGROUND SERVICE 120/240 VAC, 60 Hz 1 PHASE, 3 WIRE N G (E) 225A Main Service Panel 9 (EL) (EL) (EL) (EL) (PV) 20A (E) 200A N G E (E) 225A SUBPANEL (E) 200A (EL) (EL) G F 5 AC DISCONNECT SAFETY SWITCH 30A NON-FUSIBLE 4 4 L1 L2 G N 1 L1 (1) 12 AWG THHN/THWN-2 CU RED Exterior L2 (1) G (1) 12 AWG THHN/THWN-2 CU BLACK 6 AWG BARE, CU ENPHASE Q-CABLE, 2-WIRE, FREE AIR 4 L1 (1) 10 AWG THHN/THWN-2 CU RED Exterior3/4 INCH L2 (1) N (1) G (1) 10 AWG THHN/THWN-2 CU BLACK 10 AWG THHN/THWN-2 CU WHITE 10 AWG THHN/THWN-2 CU GREEN EMT 2 L1 (1) 10 AWG THHN/THWN-2 CU REDL2(1) G (1) 10 AWG THHN/THWN-2 CU BLACK 10 AWG THHN/THWN-2 CU GREEN 3/4 INCH *3 L1 (1) 10 AWG THHN/THWN-2 CU REDL2(1) G (1) 10 AWG THHN/THWN-2 CU BLACK 10 AWG THHN/THWN-2 CU GREEN 3/4 INCH EMT* *TYPE NM (ROMEX) OR UF CABLE IS PERMITTED FOR INTERIOR OR ATTIC RUNS AND SHALL BE USED WHEN ELECTRICAL CODE PERMITS *TYPE UF CABLE MAY BE SUBSTITUTED FOR USE IN CONDUIT WHERE ELECTRICAL CODE PERMITS FINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER. MUST COMPLY WITH MAX MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. OTHER NOTES MI MECHANICAL INTERLOCK 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV5 Electrical 3-Line Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e NUMBER OF MODULES PER CIRCUIT PV CIRCUIT SPECIFICATIONS RATED AC OUTPUT CURRENT (IOUT) MINIMUM AMPACITY (IOUT x 125%) OVERCURRENT PROTECTION RATING CIRCUIT 1 PRIMARY STRUCTURE DETACHED STRUCTURE WIRE SIZE SPECIFICATIONS CONDUCTOR MATERIAL CONDUCTOR TYPE 1 2 3 4 5 6 7 8 9 10 MINIMUM CONDUCTOR AMPACITY 16.88A AC CONDUCTOR SIZE CONDUCTOR AMPACITY AMBIENT TEMPERATURE ADJUSTMENT FACTOR CONDUIT FILL ADJUSTMENT FACTOR ADJUSTED CONDUCTOR AMPACITY COMBINED AC OUTPUT CURRENT (COUT) MINIMUM AMPACITY (COUT x 125%) COMBINED PV BREAKER RATING WIRE RUN DISTANCE (FT) CALCULATED VOLTAGE DROP TOTAL PV VOLTAGE DROP WIRE TAG #1 WIRE TAG #2 WIRE TAG #3 WIRE TAG #4 WIRE TAG #5 WIRE TAG #6 TOTAL VOLTAGE DROP 0.8% 0.77% 0.28% 0.14% 0% 0% 1.990000% DATA SOURCE STATE CITY WEATHER STATION HIGH TEMP 2% AVG EXTREME MINIMUM TEMP ASHRAE Weather Station Data Washington Yelm ELECTRICAL INFORMATION UTILITY ELECTRICAL SYSTEM NEW PV SYSTEM QUANTITY TYPE OUTPUT CURRENT PV MODULES INVERTERS WATTAGE TYPE NOMINAL VOLTAGE OUTPUT POWER 10 Silfab Solar SIL-430 QD 430W DC Enphase IQ8M-72-M-US 1.35A AC 240V AC 325W AC AC SYSTEM SIZE DC SYSTEM SIZE 3.25kW AC 4.3kW DC DESIGN LOCATION AND TEMPERATURES 1-Phase, 3-Wire, 60Hz, 120/240V 1-Phase, 3-Wire, 60Hz, 120/240V TACOMA NARROWS 28°C -4°C CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 CIRCUIT 6 CIRCUIT 7 CIRCUIT 8 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 100000000 00000 13.5A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 16.9A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 13.5A 16.9A 20AA 0.0A 0AA 0.0A CU THHN/THWN-2 12 AWG 30A 1 1 30A 16.88A AC 16.88A AC 16.88A AC ----A AC ----A AC ----A AC ----A AC ----A AC ----A AC CU CU CU ---- ---- ---- ---- ---- ---- THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 ---- ---- ---- ---- ---- ---- 10 AWG 10 AWG 10 AWG ---- 40A 40A 40A ----A ----A ----A ----A ----A ----A 1 1 1 ---- ---- ---- ---- ---- ---- 1 1 1 ---- ---- ---- ---- ---- ---- 40A 40A 40A ----A ----A ----A ----A ----A ----A 66 55 20 10 ---- ---- ---- ---- ---- ---- 0.8% 0.77% 0.28% 0.14% 0% 0% 0% 0% 0% 0% MAIN SERVICE PANEL BUSBAR RATING PANEL OCPD RATING AVAILABLE BACKFEED (120% RULE) PV BREAKER RATING SUBPANEL 1 SUBPANEL 2 225A 200A 70A 20A 225A 200A 70A ----A ----A ##A PV BREAKER BACKFEED CALCULATIONS "120% RULE" (BUSBAR RATING * 120%) - OCPD RATING = AVAILABLE BACKFEED 20A 20A *THESE CALCULATIONS ARE ONLY APPLICABLE IF PV INTERCONNECTION IS A LOAD SIDE BREAKER. *PV BREAKER MUST BE RATED LESS THAN OR EQUAL TO AVAILABLE BACKFEED FOR CODE COMPLIANCE* 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV6 Electrical Calculations Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e UTILITY METER MAIN SERVICE PANEL POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS *LABEL INSTALLED NEXT TO PV BREAKER PV AC DISCONNECT RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PV COMBINER BOX PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS AUTHORIZED PERSONNEL ONLY NO DC WIRES PRESENT RAPID SHUTDOWN TEST NOT REQUIRED WARNING! WARNING LABELS NET METER MULTIPLE SOURCES OF POWER CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE OF SIGHT OF UTILITY METER. PHOTOVOLTAIC SYSTEM AC DISCONNECT!! 240 VNOMINAL OPERATING AC VOLTAGE RATED AC OUTPUT CURRENT 13.5 A ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! IN CASE OF EMERGENCY, PLEASE CONTACT: BLUE RAVEN SOLAR (800) 377-4480 NOTICE 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: January 14, 2025 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: PV DC SYSTEM SIZE: PV AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 3.250 kW AC 4.300 kW DC BLUE RAVENSOLAR PV7 Warning Labels Jordan Davis 1279365 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m W A Ye l m , W a s h i n g t o n 9 8 5 9 7 92 2 4 C o n i n e S t S E To m m y M o o r e DRAWING NUMBER:SS BLUE RAVEN SOLAR SIL-420/430 QD SILFABSOLAR.COM •Improved Shade Tolerance •Improved Low-Light Performance •Increased Performance in High Temperatures •Enhanced Durability •Reduced Degradation Rate •Industry-Leading Warranty INTRODUCING NEXT-GENERATION N-TYPE CELL TECHNOLOGY NTC MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 21 kg ± 0.2 kg 46.3 lbs ± 0.4 lbs Dimensions (H x L x D) 1721 mm x 1133 mm x 35 mm 67.8 in x 44.6 in x 1.37 in Maximum surface load (wind/snow)* 4000 Pa rear load / 5400 Pa front load 83.5 lb/ft 2 rear load / 112.8 lb/ft2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 108 Half cells - N-Type Silicon solar cell 182 mm x 91 mm 108 Half cells - N-Type Silicon solar cell 7.16 in x 3.58 in Glass 3.2 mm high transmittance, tempered, antireflective coating 0.126 in high transmittance, tempered, antireflective coating Cables and connectors (refer to installation manual) 1350 mm, ø 5.7 mm, MC4 from Staubli 53.1 in, ø 0.22 in (12 AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized aluminum (Black) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated, 3 diodes TEMPERATURE RATINGS Temperature Coefficient Isc 0.04 %/°C Temperature Coefficient Voc -0.24 %/°C Temperature Coefficient Pmax -0.29 %/°C NOCT (± 2 °C) 45 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 98% end 1st yr ≥ 94.7% end 12th yr ≥ 90.8% end 25th yr ≥ 89.3% end 30th yr SHIPPING SPECS Modules Per Pallet: 26 or 26 (California) Pallets Per Truck 32 or 30 (California) Modules Per Truck 832 or 780 (California) CERTIFICATIONS Product UL 61215, UL 61730, CSA C22.2#61730, IEC 61215, IEC 61730, IEC 61701 (Salt Mist Corrosion), IEC 62716 (Ammonia Corrosion), CEC Listed, UL Fire Rating: Type 2 Factory ISO9001:2015 * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. 44 . 6 " [ 1 1 3 3 m m ] 11.8" [300.5mm]44.1" [1120mm]11.8" [300.5mm] Ø0 . 1 7 " [ Ø 4 . 2 m m ] ( x 2 ) Gr o u n d i n g H o l e Mounting Hole (x4) Drainage Hole (x8) 43 " [ 1 0 9 3 m m ] 2.4" [60mm]8" [200mm] 53.15" [1350mm] Cable Length 1.4" [35mm] 1. 4 " [ 3 5 m m ] 0.06" [1.5mm] 67.8" [1721mm] 1. 4 " [ 3 5 m m ] 0.5" [12mm] 0. 3 " [ 7 m m ] 0. 6 " [ 1 5 m m ] Si d e Ba c k V i e w Pr o f i l e ELECTRICAL SPECIFICATIONS 420 430 Test Conditions STC NOCT STC NOCT Module Power (Pmax) Wp 420 313 430 321 Maximum power voltage (Vpmax) V 33.08 30.86 33.25 31.02 Maximum power current (Ipmax) A 12.70 10.15 12.93 10.33 Open circuit voltage (Voc) V 38.84 36.52 38.91 36.58 Short circuit current (Isc) A 13.50 10.85 13.87 11.15 Module efficiency % 21.5% 20.1% 22.1% 20.6% Maximum system voltage (VDC) V 1000 Series fuse rating A 25 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m2 • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10 W. 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 info@silfabsolar.com SILFABSOLAR.COM 7149 Logistics Lane Fort Mill SC 29715 USA T +1 839.400.4338 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-420/430-QD-20240227 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2022. Silfab Solar® is a registered trademark of Silfab Solar Inc. SILFAB SOLAR INC. 430 STC NOCT 430 321 33.25 31.02 12.93 10.33 38.91 36.58 13.87 11.15 22 1%20 6%22.1%20.6% DRAWING NUMBER:SS BLUE RAVEN SOLAR$SULO th, 202 To Whom It May Concern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nirac, Inc. • www.unirac.com 1411 Broadway Blvd. NE• Albuquerque, NM • 87102-1545 • Ph: (505) 242-6411 • Fax: (505) 242-6412 DRAWING NUMBER:SS BLUE RAVEN SOLAR IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built using advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to the IQ8 Series Microinverters that have integrated MC4 connectors. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer’s instructions. Easy to install • Lightweight and compact with plug- and-play connectors • Power line communication (PLC) between components • Faster installation with simple two- wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) NOTE: • IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Gateway is required to change the default grid profile at the time of installation to meet the local Authority Having Jurisdiction (AHJ) requirements. IQ8MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 * Meets UL 1741 only when installed with IQ System Controller 2. ** IQ8M and IQ8A support split-phase, 240 V installations only. #Šʏ‚?''ŠUS (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters B[{Š#Šɷ#ɸ [BŠ‚ B}ȱZɽȰȫɽZɽ‚ B}ȱɽȰȫɽZɽ‚ Commonly used module pairings1 W 260–460 295–500 Module compatibility To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module Isc. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator MPPT voltage range V 30–45 32–45 Operating range V 16–58 Minimum/Maximum start voltage V 22/58 Maximum input DC voltage V 60 Maximum continuous input DC current A 12 Maximum input DC short-circuit current A 25 Maximum module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 ungrounded array; no additional DC side protection required; AC side protection requires max 20 A per branch circuit aŠ{Š#Šɷɸ [BŠ‚ B}ȱZɽȰȫɽZɽ‚ B}ȱɽȰȫɽZɽ‚ Peak output power VA 330 366 Maximum continuous output power VA 325 349 Nominal grid voltage (L-L) V 240, split-phase (L-L), 180° Minimum and Maximum grid voltage2 V 211-264 Maximum continuous output current A 1.35 1.45 Nominal frequency ?ų 60 Extended frequency range ?ų 47–68 AC short-circuit fault current over three cycles Arms 2 Maximum units per 20 A (L-L) branch circuit3 11 Total harmonic distortion % <5 Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable) 0.85 leading ... 0.85 lagging Peak efficiency %97.8 97.7 CEC weighted efficiency %97.5 97 Nighttime power consumption mW 21 22 Z'?[BT#Š Ambient temperature range -40°C to 60°C (-40°F to 140°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D) 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2") Weight 1.1 kg (2.43 lbs) Cooling Natural convection–no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor IQ8MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 B}ȱZɽȰȫ ɽZɽ‚ 260–460 30–45 B}ȱZɽȰȫ ɽZɽ‚ 330 325 1.35 97.8 97.5 21 •Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) •Meets CA Rule 21 (UL 1741-SA) and IEEE DRAWING NUMBER:SS BLUE RAVEN SOLAR The Enphase Q Cable™ and accessories are part of the latest generation Enphase IQ System™. These accessories provide simplicity, reliability, and faster installation times. Enphase Q Cable Accessories To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Q Cable Accessories REGION: Americas Enphase Q Cable • Two-wire, double-insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable • New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits • Available in male and female connector types To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-06-26 CONDUCTOR SPECIFICATIONS 'IVXMƤGEXMSR UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Field-wireable connector (male)Q-CONN-10M Make connections from any open connector Field-wireable connector (female)Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female)Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor¹ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S SOLARLOK). 150mm/5.9” to MC4. Enphase EN4 non-terminated adaptor¹ECA-EN4-FW *SVƤIPH[MVMRKSJ90GIVXMƤIH('GSRRIGXSVW)2 8)4:7730 %603/ XS non-terminated cable. 150mm/5.9” Enphase EN4 to MC4 adaptor (long)¹ECA-EN4-S22-L Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split cell modules or PV modules with short DC cable. 600mm/23.6” Replacement DC Adaptor (MC4)Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX)Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) 1. 5YEPMƤIHTIV90WYFNIGX Enphase Q Cable Accessories TERMINATOR Terminator cap for unused cable ends, sold in packs of ten (Q-TERM-10) SEALING CAPS Sealing caps for unused aggregator and cable connections (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL Plan to use at least one per installation, sold in packs of ten (Q-DISC-10) CABLE CLIP Used to fasten cabling to the racking or to secure looped cabling, sold in packs of one hundred (Q-CLIP-100) DRAWING NUMBER:SS BLUE RAVEN SOLAR © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change.IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre-wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. The IQ Combiner 5/5C, IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. 5-year limited warranty Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect (CELLMODEM-M1-06-SP-05), only with IQ Combiner 5C • Supports flexible networking: Wi-Fi, Ethernet, or cellular • Provides production metering (revenue grade) and consumption monitoring Easy to install • Mounts to one stud with centered brackets • Supports bottom, back, and side conduit entries • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV branch circuits • Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Reliable • Durable NRTL-certified NEMA type 3R enclosure • 5-year limited warranty • 2-year labor reimbursement program coverage included for both the IQ Combiner SKUs* • UL1741 Listed X-IQ-AM1-240-5 X-IQ-AM1-240-5C IQ Battery 5P Fully integrated AC battery system. Includes six field-replaceable IQ8D-BAT Microinverters. IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) simplify the installation process. IQ System Controller 3/3G Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power.system from grid power to backup IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. p DATA SHEET *For country-specific warranty information, see the https://enphase.com/installers/resources/warranty page. IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 (X-IQ-AM1-240-5) IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSIC12.20 ±0.5%), consumption monitoring (± 2.5%), and IQ Battery monitoring (±2.5%). Includes a silver solar shield to deflect heat. IQ Combiner 5C (X-IQ-AM1-240-5C) IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%), consumption monitoring (±2.5%) and IQ Battery monitoring (±2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)¹. Includes a silver solar shield to deflect heat. WHAT’S IN THE BOX IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System Busbar 80 A busbar with support for 1 × IQ Gateway breaker and  4 × 20 A breaker for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Pre-wired revenue-grade solid-core CT, accurate up to ±0.5% Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to ±2.5% IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to ±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Enphase Mobile Connect (only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for the COMMS-KIT-02 board ACCESSORIES AND REPLACEMENT PARTS (NOT INCLUDED, ORDER SEPARATELY) CELLMODEM-M1-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan CELLMODEM-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan Circuit breakers (off-the-shelf) Supports Eaton BR2XX, Siemens Q2XX and GE/ABB THQL21XX Series circuit breakers (XX represents 10, 15, 20, 30, 40, 50, or 60). Also supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with the hold-down kit. Circuit breakers (provided by Enphase)BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P- 240V-B (more details in the “Accessories” section) XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 5/5C X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws) XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board (PCB) for IQ Combiner 5/5C ELECTRICAL SPECIFICATIONS Rating 80 A System voltage and frequency 120/240 VAC, 60 Hz Busbar rating 125 A Fault current rating 10 kAIC Maximum continuous current rating (input from PV/storage) 64 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers only (not included) Maximum total branch circuit breaker rating (input) 80 A of distributed generation/95 A with IQ Gateway breaker included IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering, included with the box 1. A plug-and-play industrial-grade cell modem for systems of up to 60 microinverters. Available in the United States, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area. DRAWING NUMBER:SS BLUE RAVEN SOLAR IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 MECHANICAL DATA Dimensions (W × H × D)37.5 cm × 49.5 cm × 16.8 cm (14.75" × 19.5" × 6.63"). Height is 21.06" (53.5 cm) with mounting brackets Weight 7.5 kg (16.5 lbs) Ambient temperature range -40°C to 46°C (-40°F to 115°F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing Communication (in-premise connectivity)Built-in CTRL board for wired communication with IQ Battery 5P and IQ System Controller 3/3G. Integrated power line communication for IQ Series Microinverters Altitude Up to 2,600 meters (8,530 feet) COMMUNICATION INTERFACES Integrated Wi-Fi 802.11b/g/n (dual band 2.4 GHz/5 GHz), for connecting the Enphase Cloud through the internet Wi-Fi range (recommended) 10 m (32.8 feet) Bluetooth BLE4.2, 10 m range to configure Wi-Fi SSID Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Cloud through the internet Cellular/Mobile Connect CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-AT-05 (included with IQ Combiner 5C) Digital I/O Digital input/output for grid operator control USB 2.0 Mobile Connect, COMMS-KIT-01 for IQ Battery 3/3T/10/10T, COMMS-KIT-02 for IQ Battery 5P Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication 90–110 kHz Web API See https://developer-v4.enphase.com Local API See guide for local API COMPLIANCE IQ Combiner with IQ Gateway UL 1741, CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016, UL 60601-1/CANCSA 22.2 No. 61010-1, IEEE 1547: 2018 (UL 1741-SB, 3rd Ed.), IEEE 2030.5/CSIP Compliant, Production metering: ANSI C12.20 accuracy class 0.5 (PV production) COMPATIBILITY PV Microinverters IQ6, IQ7, and IQ8 Series Microinverters COMMS-KIT-01 2 IQ System Controller EP200G101-M240US00 IQ System Controller 2 EP200G101-M240US01 IQ Battery ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA COMMS-KIT-02 3 IQ System Controller 3 SC200D111C240US01, SC200G111C240US01 IQ Battery IQBATTERY-5P-1P-NA 2. For information about IQ Combiner 5/5C compatibility with the 2nd-generation batteries, refer to the compatibility matrix. 3. IQ Combiner 5/5C comes pre-equipped with COMMS-KIT-02.IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 Mobile Connect 4G-based LTE-M1 cellular modem with a 5-year data plan (CELLMODEM-M1-06-SP-05 for Sprint and CELLMODEM-M1-06-AT-05 for AT&T) Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole, 15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-SOLID 200 A revenue-grade solid core Production CT with <0.5% error rate (replacement SKU) CT-200-CLAMP 200 A clamp-style consumption and battery metering CT with <2.5% error rate (replacement SKU) Accessories DRAWING NUMBER:SS BLUE RAVEN SOLAR © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ Gateway The IQ Gateway delivers solar production and energy consumption data to Enphase Installer Portal monitoring and analysis software for comprehensive, remote maintenance, and management of Enphase systems. Smart • Enables web-based monitoring and control • Provides bidirectional communications for remote upgrades • Supports power export limiting and zero-export applications Simple • Easy system configuration using Enphase Installer App • Flexible networking with Wi-Fi, Ethernet, or cellular Reliable • Designed for installation indoors or outdoors in a NEMA 3R rated enclosure • 5-year limited warranty • ENV2-IQ-AM1-240 complies with IEEE® 1547:2018 (UL 1741-SB, 3rd Ed.) DATA SHEET With integrated production metering and optional consumption monitoring, the IQ Gateway is the platform for total energy management. It integrates with the IQ System Controller and IQ Battery. IQ Battery All-in-one AC coupled storage system that is reliable, smart, simple, and safe. It provides backup capability and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process. IQ System Controller Provides microgrid interconnect device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. IQ-G-DSH-00111-3.0-EN-US-2023-12-20 IQ Gateway MODEL NUMBER ENV-IQ-AM1-240, ENV2-IQ-AM1-240 IQ Gateway ENV-IQ-AM1-240 ENV2-IQ-AM1-240 (IEEE® 1547:2018) IQ Gateway integrates revenue grade PV production metering (ANSI C12.20 ±0.5%), consumption metering (±2.5%), and battery metering (±2.5%) with IQ Battery 5P. Includes one 200 A continuous rated Production Current Transformer (CT). ACCESSORIES - ORDER SEPARATELY Mobile Connect COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Consumption monitoring CT and IQ Battery 5P metering CT CT-200-SPLIT CT-200-CLAMP Split-core and clamp style CTs with 2.5% accuracy enable whole home and IQ Battery 5P metering Communications Kit COMMS-KIT-01 COMMS-KIT-02 Installed at the IQ Gateway. For communications with IQ Battery and IQ System Controller. Includes USB cable for connection to IQ Gateway or IQ Combiner and allows wireless communication with IQ Battery and IQ System Controller. POWER REQUIREMENTS AC power requirements 120/240 V, 120/208Y V, or 127/220Y V. Three-wire. 60 Hz. IQ Gateway breaker 2-pole and maximum 20 A overcurrent protection required Typical power consumption 5 W CAPACITY Number of microinverters polled Up to 300 MECHANICAL AND ELECTRICAL DATA Dimensions (W × H × D) 21.3 cm × 12.6 cm × 4.5 cm (8.4 in × 5 in × 1.8 in) Weight 1.09 lb Ambient temperature range -40°C to 65°C (-40°F to 149°F) [ENV-IQ-AM1-240] -40°C to 50°C (-40°F to 122°F) [ENV2-IQ-AM1-240] -40°C to 46°C (-40°F to 115°F) if installed in an enclosure Environmental rating IP30. For installation indoors or in an NRTL-certified, NEMA type 3R or better-rated enclosure, if installing outdoors. Altitude Up to 2,600 meters (8,530 feet) COMMUNICATION INTERFACES Integrated Wi-Fi 802.11b/g/n (2.4 GHz, 5 GHz), for connecting the Enphase Cloud via the internet. Wi-Fi range (recommended) 10 m Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Cloud via the internet. Mobile Connect CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (to be purchased separately, mandatory for sites with IQ Battery) Digital I/O Digital input/output for grid operator control USB 2.0 For Mobile Connect and Communications Kit Access point (AP) mode For a connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one Production CT, and one battery CT (for IQ Battery 5P) Power line communication (PLC) 90 kHz–110 kHz (Class B), to microinverters. Web API Refer to https://developer-v4.enphase.com Local API Refer to guide for local API LED indicators From top to bottom: Cloud connectivity, Wi-Fi access point mode, PV production state, PLC communications state Configured via Enphase Installer App and Enphase Installer Platform IQ-G-DSH-00111-3.0-EN-US-2023-12-20 DRAWING NUMBER:SS BLUE RAVEN SOLAR POWER PRODUCTION/EXPORT LIMITING VIA THE IQ GATEWAY’S DIGITAL IO Maximum relays read 4 Capabilities supported Power production limiting (Production CT/s required), power export limiting (Production CT/s required and Consumption CT/s – Load with Solar configuration) Minimum IQ Gateway version v7.3.120 Cable configurations 18 AWG, UL-Std. 62, 600 V, 105°C, and minimum 0.03 inches average thickness Signal voltage range 2.5 V–5 V (digital high), 0 V–1.9 V (digital low) Terminal blocks Five terminals, up to 0.002 in2 Configuration via Enphase Installer App, Enphase Installer Platform (site settings) SCOPE OF DELIVERY Package dimensions (H × W × D) 6.3 in × 10.8 in × 3.9 in Package weight 2.2 lb Aluminium DIN rail 4.9 in Current transformers (CTs) One CT-200-SOLID included COMPLIANCE Compliance CA Rule 21 (UL 1741-SA), IEEE® 1547:2018 - UL 1741-SB, 3rd Ed.(ENV2-IQ-AM1-240), UL 61010-1 CAN/CSA C22.2 No. 61010-1 Title 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 (PV production only) COMPATABILITY IQ System Controller SC200D111C240US01, SC200G111C240US01, EP200G101-M240US01, EP200G101-M240US00 IQ Battery IQBATTERY-5P-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA Microinverter IQ6, IQ7, and IQ8 Series Microinverters All dimensions in inches All dimensions in inches 5 8.41.8 5 8.4 1. 8 Enphase Mobile Connect 4G-based LTE-M1 cellular modem with a 5-year data plan (CELLMODEM-M1-06-SP-05 for Sprint and CELLMODEM-M1-06-AT-05 for AT&T) Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole, 15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-SOLID 200 A revenue grade solid core Production CT with <0.5% error rate (replacement SKU) CT-200-CLAMP 200 A clamp-style consumption and battery metering CT with <2.5% error rate (replacement SKU) Accessories IQ-G-DSH-00111-3.0-EN-US-2023-12-20 © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. Revision history REVISION DATE DESCRIPTION DSH-00111-3.0 December 2023 Updated power requirement and added IG Gateway breaker values. DSH-00111-2.0 August 2023 Updated temperature specification for ENV2-IQ-AM1-240. DSH-00111-1.0 June 2023 Updated altitude and recommended maximum microinverters on a site. IQ-G-DSH-00111-3.0-EN-US-2023-12-20 DRAWING NUMBER:SS BLUE RAVEN SOLAR DRAWING NUMBER:SS BLUE RAVEN SOLAR JB-1.2, JB-1.XL Specification Sheet PV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: JB-1.2: 80 Amps; JB-1.XL: 120 Amps • Allowable Wire: 14 AWG – 6 AWG • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 – 12:12 • Max Side Wall Fitting Size: 1” • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741, CSA C22.2 No. 290; JB-1.XL: UL1741, CSA C22.2 No. 290 - Approved wire connectors: must conform to UL1741, CSA C22.2 No. 290 • System Marking: Interek Symbol and File #5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. A. System Specifications and Ratings Phone: 385-202-4150 | www.ezsolarproducts.com Table 1: Typical Wire Size, Torque Loads and Ratings 1 Conductor ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 600V 30 amp6.2-8.85 ABB ZS10 terminal block ABB ZS16 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 600V 40 amp8.85-14.16 ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 600V 50 amp8.85 Ideal 452 Red 8-18 awg Sol/Str Self-Torque Self-Torque 600V 4-24 awg 10-20 awg Sol/Str 1.6-2.4 600V 60 amp14.6-21.24 10-20 awg 16-24 awg Sol/Str 600V 30 amp 2 Conductor Type NM Inch Lbs Voltage Current Torque WING-NUT Wire Connector Ideal 451 Yellow 10-18 awg Sol/Str Self-Torque Self-Torque 600V Ideal, In-Sure WAGO, 2204-1201 10-20 awg 10-24 awg Sol/Str 600V 30 ampWAGO, 221-612 10-14 awg Sol/Str Self-Torque Self-Torque Self-Torque Self-Torque Self-Torque Self-Torque 6-12 awg Sol/StrDottie DRC75 ESP NG-53 Snap-In Snap-In 4-6 awg Sol/Str 45 10-14 awg Sol/Str 35 2000V ESP NG-717 4-6 awg Sol/Str 45 10-14 awg Sol/Str 35 2000V Brumall 4-5,3 4-6 awg Sol/Str 45 10-14 awg Sol/Str 35 2000V 600V WING-NUT Wire Connector Push-In Connector Part #39 Table 2: Minimum wire-bending space for conductors through a wall opposite terminals in mm (inches) Wire size, AWG or mm (inch) 14-10 (2.1-5.3) 8 (8.4) 6 (13.3) Not Specified 38.1 (1-1/2) 50.8 (2) - - - - - - - - - kcmil (mm2) mm (inch) mm (inch) mm (inch) 1 2 3 4 or More Wires per terminal (pole) PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. Phone: 385-202-4150 www.ezsolarproducts.com ITEM No. 1 1 1 6 6 JB-1.2 Body POLYCARBONATE WITH UV INHIBITORS POLYCARBONATE WITH UV INHIBITORS #10 x 1-1/4” Phillips pan head screw #8 x 3/4” Phillips pan head screw JB-1.2 Lid2 3 4 PART NUMBER DESCRIPTION QTY Size SCALE: 1:2 WEIGHT: 1.45 LBS SHEET 1 of 3 DWG. NO. Rev B JB-1.2 Torque Specification: certification: WEIGHT: 15-20 LBS 1.45 LBS UL 1741, nema 3r CSA C22.2 No. 290 Patents: ezsolarproducts.com/patents DRAWING NUMBER:SS BLUE RAVEN SOLAR ISSUE DATE: DATE D'EMISSION:2009 04 30RIGID PVC CONDUIT FITTINGS SUPERCEDES: REMPLACE:JB444 JUNCTION BOXES 2004 07 15 5 Page: CONDUIT – 41.1 B A C ® E ® C B D PRODUCT CODE PART NUMBER NOMINAL SIZE ABC (in)(mm) (in) (mm) (in) (mm) (in) (mm) 076668 J444 STAHLIN 4 103 3.675 93 4.000 102 3.450 88 076259 AMJB444 ALLIED 4 103 3.675 93 4.000 102 3.450 88 077643* 2037-424T CANLET 4 103 3.675 93 4.000 102 3.450 88 077696 JB 444 4 103 4.000 101 4.395 112 3.950 101 PRODUCT CODE PART NUMBER NOMINAL SIZE DEVOLUME (in)(mm) (in) (mm) (in) (mm) (cu. In) (cu. Cm) 076668 J444 STAHLIN 4 103 4.180 106. 3.850 98 51.5 844.6 076259 AMJB444 ALLIED 4 103 4.180 106 3.850 98 51.5 844.6 077643* 2037-424T CANLET 4 103 4.180 106 3.850 98 51.5 844.6 077696 JB 444 4 103 4.170 106 3.930 100 51.5 844.6 PRODUCT CODE PART NUMBER NOMINAL SIZE GASKET CODE INSERT CODE SCREW CODE M.FEET CODE(in)(mm) 076668 J444 STAHLIN 4 103 072538 (4) 076259 AMJB444 ALLIED 4 103 072538 (4) 077643* 2037-424T CANLET 4 103 072538 (4) 077696 JB 444 4 103 097731 072538 (4) 072522 (4) 097747 072539 (2) 072513 (2) * BOX WITH MOLDED MOUNTING FEET, INSERT ONLY; NO COVER, OR GASKET, UL LISTED 576J ISSUE DATE: DATE D'EMISSION:2009 04 30RIGID PVC CONDUIT FITTINGS SUPERCEDES: REMPLACE:JB444 JUNCTION BOXES 2004 07 15 5 Page: CONDUIT – 41.2 0.700” COVER DIMENSIONS 4.010” (102mm) 4.010” (102mm) 0.245” (6 mm) 0.190” DIA 0.250” 1.970” Small Mounting Feet Product Code 097747 0.175” DRAWING NUMBER:SS BLUE RAVEN SOLAR “Stay Connected” with Solar Power Components ® 1-4b1-800-526-4182 • 732-286-1800 (NJ) • FAX: 732-244-8843 • www.heyco.com Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring The Ultimate in Liquid Tight Strain Relief Protection •Two new cordgrips now accommodate the Enphase Q Cable – M3231GCZ (1/2˝ NPT) and M3234GDA-SM (3/4˝ NPT). •The 1/2˝ version provides liquid tight entry for one Enphase Q Cable – .24 x .38˝ (6,1 x 9,7 mm). •The 3/4˝ version provides liquid tight entry for up to two Enphase Q Cables – .24 x .38” (6,1 x 9,7 mm) and an additional .130” (3,3 mm) dia. hole for a #8 solid grounding cable. •The 3/4˝ version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. •Rated for use with DG Cable. Material Nylon 6/6 with TPE Sealing Gland Certifications Listed under Underwriters’ Laboratories File E504900 CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40°F (-40°C) to 239°F (115°C) Dynamic -4°F (-20°C) to 212°F (100°C) IP Rating IP 68 GLAND PART NO. DESCRIPTION PART DIMENSIONS CONFIGURATION A B C D E Conductors or Clearance Max. O.A. Thread Wrenching Nut Type Size No. Black Hole Dia. Length Length Thickness Flat Size * mm. in. mm. in. mm. in. mm. in. mm. in. mm. Oval Gland Q Cable 6,1x 9,7 1 M3231GCZ LTCG 1/2 6.1x9.7MM .875 22,2 1.70 43,2 .61 15,5 .21 5,3 .98 24,9 Break-Thru Skinned Over Gland Q Cables 6,1x 9,7 2 SMCG 3/4 2-6.1x9.7MMplusM3234GDA-SM 1.040 26,4 2.00 50,8 .62 15,7 .25 6,4 1.30 33,0 Ground 3,3 1 1-3.3MM Metal Locknuts INCLUDED. Heyco®Helios®UVX Clip – Blind Mount •The jersey pine tree mounting style installs easily with superior holding power. •UVX nylon protects from corrosion due to outdoor exposure. •Installs into .260˝ (6,6 mm) mounting hole. •Holds up to 2 cables between .230 - .315˝ (5,8 - 8,0 mm) each. •Cables install with fingertip pressure. •Molded from our robust UVX nylon 6/6 with extended UV capabilities for our Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F (-20°C) to 185°F (85°C) PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL RANGE HOLE DIA. HEIGHT Minimum Maximum 1-2 Wires A C in. mm. in. mm. in. mm. in. mm. 1-2 Wires .028 0,7 .250 6,4 .23 (5,8 mm) - .32 (8,0 mm)S6520 Helios UVX Clip 100 Pack .260 6,6 .96 24,4each cable S6560 Helios UVX Clip Bulk SUGGESTED CLEARANCE HOLE FOR NONTHREADED MOUNTING AD C B E SEALING NUT INTEGRAL SEALING RING ALL NEW PRODUCT! ALL NEW PRODUCT! The 3/4˝ version provides liquid tightpqg entry for up to two Enphase Q Cables –yp p .24 x .38” (6,1 x 9,7 mm) and an (, , ) additional .130” (3,3 mm) dia. hole for(, ) a #8 solid grounding cable. Q Cables 6,1x9,7 2 SMCG 3/4 2-6.1x9.7MMplusM3234GDA-SM 1.040 26,4 2.00 50,8 .62 15,7 .25 6,4 1.30 33,01-3.3MM3,3 1Ground Break-Thru Skinned Over Gland The 3/4˝ version utilizes our skinned- over technology so any unused holes gy y will retain a liquid tight seal. DRAWING NUMBER:SS BLUE RAVEN SOLAR SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. SFM INFINITY 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre-assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. SYSTEM OVERVIEW BONDING AND ACCESSORIES 2MW 3MW PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules 2 3 4 5 6 1 1 4 3 5 6 7 SFM INFINITY 15 Attachments RAIL 20 Attachments 87%OF HOMEOWNERS PREFER MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. 7 2 PART NAME DESCRIPTION TRIMRAIL Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post-install array leveling. SPLICE Connects and supports modules. Provides east-west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 19SYSTEM BONDING & GROUNDING E-W BONDING PATH: (:PRGXOHWRPRGXOHERQGLQJLVDFFRPSOLVKHG ZLWKSUHLQVWDOOHGERQGLQJSLQVZKLFKHQJDJH RQWKHVHFXUHVLGHRIWKH0LFURUDLO70DQGVSOLFH TRIMRAIL BONDING PATH: 7ULPUDLOWRPRGXOHERQGLQJLVDFFRPSOLVKHGZLWK ERQGLQJFODPSZLWKLQWHJUDOERQGLQJSLQDQG ERQGLQJ7EROW(refer also to alternate method) N-S BONDING PATH: 16PRGXOHWRPRGXOHERQGLQJLV DFFRPSOLVKHGZLWKERQGLQJFODPSZLWKLQWHJUDO ERQGLQJSLQV(refer also to alternate method) System bonding is accomplished through modules. System grounding accomplished by attaching DJURXQGOXJWRDQ\PRGXOHDWDORFDWLRQRQWKHPRGXOHVSHFLʳHGE\WKHPRGXOHPDQXIDFWXUHU LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) • PRXQWLQJKDUGZDUH • 7RUTXH IWOE • $:*6ROLGRU6WUDQGHG LUG DETAIL & TORQUE INFO Ilsco Flange Lug (SGB-4) • ȧPRXQWLQJKDUGZDUH • 7RUTXH LQOE • $:*6ROLGRU6WUDQGHG LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • ȧPRXQWLQJKDUGZDUH • 7RUTXH IWOE • $:*6ROLGRU6WUDQGHG NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs WEEBLUG Single Use Only Star Washer is Single Use Only Ñ $OWHUQDWHPHWKRG $OWHUQDWHPHWKRG DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 20UL CODE COMPLIANCE NOTES SYSTEM LEVEL FIRE CLASSIFICATION 7KHV\VWHPʳUHFODVVUDWLQJUHTXLUHVLQVWDOODWLRQLQWKHPDQQHUVSHFLʳHGLQWKH 681)5$0(0,&525$,/ 6)0 ,QVWDOODWLRQ*XLGH6)0KDVEHHQFODVVLʳHGWR WKHV\VWHPOHYHOʳUHSRUWLRQRI8/7KLV8/FODVVLʳFDWLRQKDVEHHQ LQFRUSRUDWHGLQWRWKH8/SURGXFWFHUWLʳFDWLRQ6)0KDVDFKLHYHG&ODVV$ % &V\VWHPOHYHOSHUIRUPDQFHIRUORZVORSH VWHHSVORSHGURRIVZKHQXVHG LQFRQMXQFWLRQZLWKW\SHDQGW\SHPRGXOHV&ODVV$% &V\VWHPOHYHOʳUH UL2703 TEST MODULES 6HHSDJHVDQGIRUDOLVWRIPRGXOHVWKDWZHUHHOHFWULFDOO\DQGPHFKDQLFDOO\WHVWHGRU TXDOLʳHGZLWKWKH681)5$0(0,&525$,/ 6)0 FRPSRQHQWVRXWOLQHGZLWKLQWKLV,QVWDOODWLRQ*XLGH •0D[LPXP$UHDRI0RGXOH VTIW •8/'HVLJQ/RDG5DWLQJV D 'RZQZDUG3UHVVXUHȡ36)3D E 8SZDUG3UHVVXUHȡ36)3D F 'RZQ6ORSH/RDGȡ36)3D •7HVWHG/RDGV D 'RZQZDUG3UHVVXUHȡ36)3D E 8SZDUG3UHVVXUHȡ36)3D F 'RZQ6ORSH/RDGȡ36)3D •0D[LPXP6SDQ IW •8VHZLWKDPD[LPXPRYHUFXUUHQWSURWHFWLRQGHYLFH2&3'RI$ •6\VWHPFRQIRUPVWR8/6WGFHUWLʳHGWR/75$( •5DWHGIRUDGHVLJQORDGRI3D3DZLWKLQFKVSDQ •39PRGXOHVPD\KDYHDUHGXFHGORDGUDWLQJLQGHSHQGHQWRIWKH6)0ORDGUDWLQJ3OHDVHFRQVXOW WKH39PRGXOHPDQXIDFWXUHU VLQVWDOODWLRQJXLGHIRUPRUHLQIRUPDWLRQ •'RZQ6ORSHGHVLJQORDGUDWLQJRI36)3DIRUPRGXOHDUHDVRIVTIWRUOHVV Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 6WHHS6ORSH /RZ6ORSH &ODVV$% & (DVW:HVW /DQGVFDSH253RUWUDLW None Required SHUIRUPDQFHLVLQKHUHQWLQWKH6)0GHVLJQDQGQRDGGLWLRQDOPLWLJDWLRQPHDVXUHV DUHUHTXLUHG7KHʳUHFODVVLʳFDWLRQUDWLQJLVYDOLGIRUDQ\URRISLWFK7KHUHLVQR UHTXLUHGPLQLPXPRUPD[LPXPKHLJKWOLPLWDWLRQDERYHWKHURRIGHFNWRPDLQWDLQ WKH&ODVV$% &ʳUHUDWLQJIRU6)0681)5$0(0,&525$,/TM FRPSRQHQWVVKDOO EHPRXQWHGRYHUDʳUHUHVLVWDQWURRIFRYHULQJUDWHGIRUWKHDSSOLFDWLRQ DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™SYSTEM CERTIFICATION PAGE 28COMPATIBLE MODULES Manufacture Module Model / Series Aleo P-Series $SWRV '1$ %)0) '1$ %)0)  '1$ %)0) : '1$ %)0) : $VWURQHUJ\ &+603&+603+9&+600 &+600+9&+600 %/ %)  +)  CHSM72M-HC Auxin $;107$;137 $;107 $;137 $[LWHF $;,EODFNSUHPLXP PP  $;,SRZHU PP  $;,SRZHU PP  $;,SUHPLXP PP  $;,SUHPLXP PP  %RYLHW %90 %90 %<'P6K & MHK-36 Series Canadian Solar &6 +.8< 06 &6 ./8 &6.0%$*&6. 063 &6106&680%$*&68 063 &6: &6$0&6 .8 &6. 03 &6.06 &63 03 &68 03 &690&6;3 &HQWURVRODU$PHULFD C-Series & E-Series &HUWDLQ7HHG &7[[0[[&7[[3[[ &7[[[0[[&7[[[0 &7[[[0[[&7[[[+& 'HKXL '+0 Eco Solargy Orion 1000 & Apollo 1000 Manufacture Module Model / Series ET Solar ET-M672BHxxxTW )UHHGRP)RUHYHU FF-MP-BBB-370 ))03%%%[[[))03%%%[[[ )UHH9ROW Mono PERC GCL GCL-P6 & GCL-M6 Series Hansol 7'$17'$1 8%$18'$1 Heliene 0030 36HULHV +&00RQRIDFLDO%LIDFLDO6HULHV +&06/%LIDFLDO HT Solar +7 0  1'9  )  +7 03 Hyundai .*0*7*5,5*7,0,+, .,6HULHV HiA-SxxxHG ,7(. L7L7+( L76(6HULHV Japan Solar JPS-60 & JPS-72 Series JA Solar -$3[[[-$0[[[6,-$0 .  [[[-$3 N [[[%%-$36<<[[[== -$3 N [[[%%-$36<<[[[== -$0 N [[[==-$06<<[[[== -$0 N [[[==-$06<<[[[== L<< LL==6&35%3+L7,%0:05 -LQNR JKM & JKMS Series Eagle JKMxxxM -.0[[[0+/9 Kyocera KU Series ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ ȫ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,' ȫ6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,' ȫ3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDWXQLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0 ȫ6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJHIRUIXUWKHULQIRUPDWLRQ Manufacture Module Model / Series /*(OHFWURQLFV LGxxxN2T-A4 /*[[[ $&(&(.1&1.171: 4&4.6&6: $ LGxxxN2T-B5 LGxxxN1K-B6 /*[[[ $&0&0.1&1.4&4. 4$&4$. $ /*[[[ 1&1.171: ( /*[[[ 1&1.1:6&6: * LGxxxN2T-J5 /*[[[ 1.1:171: / /*[[[ 1&4&4. 1 /*[[[ 1&1.1:4&4. 9 LONGi /5 +,%+,++3%+3+ [[[0 /5 +,++3+ [[[0 /5 %3+%'+,%' [[[0 PP /5 %. 3( +3% +3+ [[[0 PP /5 %. 3( 3% 3+ [[[0 PP /5 %3 +%' +,%' [[[0 PP /5 +9 %. 3( 3+ 3% +3+ [[[0 PP /5 %. +9 3( 3% 3+ [[[0 PP Meyer Burger 0H\HU%XUJHU%ODFN 0H\HU%XUJHU:KLWH Mission Solar Energy MSE Series 0LWVXELVKL MJE & MLE Series 1HR6RODU3RZHU&R '0 '36HULHV Electrical Bonding and Grounding Test Modules 7KHOLVWEHORZLVQRWH[KDXVWLYHRIFRPSOLDQWPRGXOHVEXWVKRZVWKRVHWKDWKDYHEHHQHYDOXDWHGDQGIRXQGWREHHOHFWULFDOO\FRPSDWLEOHZLWKWKH6)0V\VWHP DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™SYSTEM CERTIFICATION PAGE 29 Manufacture Module Model / Series 5(& FRQW 7ZLQ3HDN6HULHV 7ZLQ3HDN6HULHV 7ZLQ3HDN%/.6HULHV 7ZLQ3HDN6 0  ;9  7ZLQ3HDN6HULHV PP 73 %ODFN Renesola 9LWUXV6HULHV 6HULHV Risen 560 0'*  0 560 SEG Solar 6(*[[[%0'+9 6(*[[[%0'7% S-Energy 61 616HULHV PP Seraphim SEG-6 & SRP-6 Series Sharp NU-SA & NU-SC Series 6LOIDE 6/$6/*%&6HULHV 6,/[[[ %/1/17+/ 0/%.1;18+&40  6RODUHYHU86$SE-166*83-xxxM-120N Solaria 3RZHU;7[[[5 $&3'%' 3RZHU;7[[[&3' 3RZHU;7[[[530 $& SolarWorld 6XQPRGXOH3URWHFW Sunmodule Plus Sonali 660WR6HULHV 660WR6HULHV 660WR6HULHV 660WR%L)DFLDO6HULHV SS 230 - 265 SunEdison )6HULHV56HULHV )/(;);66HULHV 6XQLYD 096HULHV 2SWLPXV6HULHV Manufacture Module Model / Series SunPower $6HULHV$%/.6350$;;;;5 ;6HULHV(6HULHV 36HULHV $[[[%/.*$&6350[[[+$& SPR-Mxxx-BLK-H-AC 6XQWHFK 673673;;;6%:QKE Talesun 73737373 73+LSRU06PDUW Tesla 6&6&%6&%6&% 7[[[+7[[[6 Trina 3$3''''(''3( 3'3('''('('( PE15H 8QLYHUVDO6RODU 81,[[[0%%81,[[[0+ 81,[[[0%% Upsolar 830[[[3 %  830[[[0 % 8QLWHG5HQHZDEOH(QHUJ\ 85( '0[[[+$' 0. [[[+$ )$.[[[ &*(* )$0[[[(*%% )$0[[[(* %% )%0[[[0)*%% URECO F6MxxxE7G-BB 9LNUDP (OGRUD 6ROLYR Somera 9681 9681[[[  0%% 9681[[[%0+ Waaree AC & Adiya Series Winaico WST & WSP Series Yingli YGE & YLM Series =16KLQH =;0=;01+B ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ ȫ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,' ȫ6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,' ȫ3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDWXQLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0 ȫ6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJHIRUIXUWKHULQIRUPDWLRQ Manufacture Module Model / Series Panasonic (939[[[ +.3.  9%+1[[[6$ 6$ 9%+1[[[6$ 6$ 9%+1[[[6$ (*  6$( 9%+1[[[.$ .$ .$ 9%+1[[[=$9%+1[[[=$ 9%+1[[[=$9%+1[[[=$ Peimar 6*[[[0 )%%) Phono Solar 3636 Prism Solar P72 Series 4&HOOV 3OXV3UR3HDN****  **  3UR3HDN/*/*/*/*/* 43($.'82%/.* 43($.'82%/.*76 43($.'82 %/. *  43($.'82/*%)) 43($.'82 %/. 0/*  43($.'82;/*** 43($.'82 %/. 0/*  43($.'82;/* FG 43($.'82%/.0/*W 47521%/.0*6(5,(6 REC $OSKD   %ODFN  3XUH 5(&[[[$$ 385(5  3XUH5; 5(&[[[13%ODFN 13HDN %ODFN 13HDN %ODFN PEAK Energy Series PEAK Energy BLK2 Series PEAK Energy 72 Series COMPATIBLE MODULES Electrical Bonding and Grounding Test Modules 7KHOLVWEHORZLVQRWH[KDXVWLYHRIFRPSOLDQWPRGXOHVEXWVKRZVWKRVHWKDWKDYHEHHQHYDOXDWHGDQGIRXQGWREHHOHFWULFDOO\FRPSDWLEOHZLWKWKH6)0V\VWHP DRAWING NUMBER:SS BLUE RAVEN SOLAR DRAWING NUMBER:SS BLUE RAVEN SOLAR DRAWING NUMBER:SS BLUE RAVEN SOLAR Listing Constructional Data Report (CDR) Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 Standard(s) Applicant Manufacturer 2 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 5 Address Country Contact Phone FAX 505-462-2190 505-843-1418 NA klaus.nicolaedis@unirac.com toddg@unirac.com 1411 Broadway Blvd NE Albuquerque, NM 87102 USA Klaus Nicolaedis Todd Ganshaw 1.0 Reference and Address Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020] Unirac, Inc Page 1 of 138 Listing Constructional Data Report (CDR) Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 1.0 Reference and Address Email Page 2 of 138 DRAWING NUMBER:SS BLUE RAVEN SOLAR Report No. 102393982LAX-002 Unirac, Inc Page 3 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 Product Brand name 2.0 Product Description Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Unirac Description The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground. The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame (at bottom flange) to contact the metal, creating a bonded connection from module to module. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the revision in effect in the jurisdiction in which the project resides. Any local electrical codes must be adhered in addition to the national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable. ED 16.3.15 (1-Jul-2022) Mandatory Report No. 102393982LAX-002 Unirac, Inc Page 4 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 2.0 Product Description Models Model Similarity Other Ratings Ratings Fuse Rating: 30A Module Orientation: Portrait or Landscape Maximum Module Size: 17.98 ft² UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading Increased size ML test: Maximum Module Size: 22.3 ft² UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope LG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 Certifications, & Increase SFM System UL2703 Module Size: Maximum Module Size: 27.76 ft² UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: - Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5” gap between the bottom of the module and the roof’s surface See section 7.0 illustractions # 1, 1a and 1b for a complete list of PV modules evaluated with these racking systems Unirac SFM NA NA ED 16.3.15 (1-Jul-2022) Mandatory DRAWING NUMBER:SS BLUE RAVEN SOLAR LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SFM INFINITY PARTS ASSEMBLY 3/1/2023 SFM DTD BUTYL ATTACHMENT REVISION DATE: DRAWING TYPE: DESCRIPTION:SFM-A23PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 3 3/4" PART # TABLE P/N DESCRIPTION SFMBTLM1 SFM DTD BUTYL ATT, MILL 7/8" 3 3/4" 1/8" BUTYL BUTYL DTD ATTACHMENT 2 1/2" 2X #14-14 SCREW, HWH, SS, SELF-DR W/ #14 EPDM WASHER LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SFM ASSEMBLY DETAIL 2/2/2021 FLASHLOC SFM TRIM KIT REVISION DATE: DRAWING TYPE: DESCRIPTION:FL-A03 PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART TABLE P/N DESCRIPTION 004095D FLASHLOC SFM TRIM KIT w/ CAP, 20 PACK TRIM CAP 3/8 TRI DRIVE NUT 3/8" x 7/8" HHCS BOLT 25 8 " (35 8 ") (21 4 ")