Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Firestop Material Submittal - WM 3705 Yelm, WA
743 Lawnsdale Road, Medford, OR 97504 3203 NE 65th St, Vancouver, WA 98663 WA-firescl922oh | OR-183279 | CA-c16 1049158 Material Submittal Walmart Yelm, WA #3705-1003 17100 State Route 507 Se, Yelm, WA 98597 Data Index 1. Pipe and Fittings a. Sch 10 & Sch 40, overhead, threaded, grooved. b. Anvil Malleable Iron Fittings c. Victaulic Mechanical Tee Style 920 2. Sprinklers a. Tyco DS-C Dry Pendent 5.6K 200° 1” (TY3555) 3. Hanger and Bracing a. TOLCO band hangers, C-type beam clamps, threaded rod (3/8”-1/2”) TAB 1 PIPE AND FITTINGS Above Ground Piping Fire sprinkler piping is a commodity and the manufacturer will be determined at time of need by availability and pricing. A single supplier will be utilized. Piping may be domestic or import supplied. Piping will be UL and/or FM approved. Piping will be Sch 40 or Sch 10 up to 2" Dia. Piping above 2" will be Sch 10. All pipe will be black steel and in accordance with ASTM A53. 743 Lawnsdale Rd Medford, OR 97504 P 541-245-0466 * F 541-245-0498 OR / 208465 * CA / C16-1017294 MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) FIGURE 1101 90˚ Elbow Size A Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1/8 6 11/16 17 0.06 0.03 0.06 0.03 1/4 8 13/16 22 0.11 0.05 0.11 0.05 3/8 10 15/16 24 0.17 0.08 0.17 0.08 1/2 15 11/8 29 0.30 0.14 0.30 0.14 3/4 20 15/16 33 0.45 0.20 0.45 0.20 1 25 11/2 38 0.73 0.33 0.73 0.33 11/4 32 13/4 44 0.97 0.44 0.97 0.44 11/2 40 115/16 49 1.30 0.59 1.30 0.59 2 50 21/4 57 2.06 0.93 2.06 0.93 21/2 65 211/16 68 3.55 1.61 3.55 1.61 3 80 31/16 78 5.46 2.48 5.46 2.48 31/2 90 37/16 87 7.10 3.22 7.10 3.22 4 100 313/16 98 8.95 4.06 8.95 4.06 5 125 41/2 114 13.90 6.30 13.90 6.30 6 150 51/8 130 23.00 10.43 23.00 10.43 A A q MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) FIGURE 1101R Reducing Elbow Size X Z Unit Weight Black Galv. NPS DN NPS DN in mm in mm lbs kg lbs kg 1/4 8 1/8 6 3/4 19 3/4 19 0.10 0.05 0.10 0.05 3/8 10 1/8 6 13/16 22 7/8 22 0.12 0.05 0.12 0.05 1/4 8 7/8 22 15/16 24 0.14 0.06 0.14 0.06 1/2 15 1/4 8 1 25 1 25 0.19 0.09 0.19 0.09 3/8 10 11/16 27 11/16 27 0.22 0.10 0.22 0.10 3/4 20 1/4 8 11/8 29 11/8 29 0.26 0.12 0.26 0.12 3/8 10 11/8 29 11/8 29 0.29 0.13 0.29 0.13 1/2 15 13/16 30 11/4 32 0.38 0.17 0.38 0.17 1 25 3/8 10 13/16 30 11/4 32 0.41 0.19 0.41 0.19 1/2 15 11/4 32 13/8 35 0.46 0.21 0.46 0.21 3/4 20 13/8 35 17/16 37 0.56 0.25 0.56 0.25 11/4 32 1/2 15 13/8 35 19/16 40 0.61 0.28 0.61 0.28 3/4 20 17/16 37 15/8 41 0.71 0.32 0.71 0.32 1 25 19/16 40 111/16 43 0.87 0.39 0.87 0.39 11/2 40 3/4 20 11/2 38 13/4 44 0.83 0.38 0.83 0.38 1 25 15/8 41 113/16 47 1.02 0.46 1.02 0.46 11/4 32 113/16 47 17/8 48 1.17 0.53 1.17 0.53 2 50 3/4 20 15/8 41 2 51 1.30 0.59 1.30 0.59 1 25 13/4 44 2 51 1.35 0.61 1.35 0.61 11/4 32 17/8 48 21/8 54 1.53 0.69 1.53 0.69 11/2 40 2 51 21/8 54 1.75 0.79 1.75 0.79 21/2 65 11/2 40 23/16 56 21/2 64 2.50 1.13 2.50 1.13 2 50 27/16 62 25/8 67 2.98 1.35 2.98 1.35 3 80 2 50 29/16 65 215/16 75 3.75 1.70 3.75 1.70 21/2 65 213/16 73 3 76 4.30 1.95 4.30 1.95 4 100 3 80 35/16 84 35/8 92 7.87 3.57 7.87 3.57 X Z q MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) FIGURE 1102 45˚ Elbow Size C Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1/8 6 11/16 17 0.07 0.03 0.07 0.03 1/4 8 3/4 19 0.11 0.05 0.11 0.05 3/8 10 13/16 22 0.16 0.07 0.16 0.07 1/2 15 7/8 22 0.22 0.10 0.22 0.10 3/4 20 1 25 0.37 0.17 0.37 0.17 1 25 11/8 29 0.54 0.24 0.54 0.24 11/4 32 15/16 33 0.86 0.39 0.86 0.39 11/2 40 17/16 37 1.13 0.51 1.13 0.51 2 50 111/16 43 1.79 0.81 1.79 0.81 21/2 65 115/16 49 3.60 1.63 3.60 1.63 3 80 23/16 56 4.48 2.03 4.48 2.03 4 100 25/8 67 7.40 3.36 7.40 3.36 5 125 31/16 78 11.46 5.20 11.46 5.20 6 150 37/16 87 19.93 9.04 19.93 9.04 q FIGURE 1103 (Straight) q FIGURE 1103R (Reducing) 90˚ Street Elbow Size A J Unit Weight Black Galv. NPS DN in mm in mm lbs kg lbs kg First size denotes female end. 1/8 6 11/16 17 1 25 0.06 0.03 0.06 0.03 1/4 8 13/16 22 13/16 30 0.10 0.05 0.10 0.05 3/8 10 15/16 24 17/16 37 0.17 0.08 0.17 0.08 1/2 15 11/8 29 15/8 41 0.28 0.13 0.28 0.13 3/4 20 15/16 33 17/8 48 0.41 0.19 0.41 0.19 1 25 11/2 38 21/8 54 0.62 0.28 0.62 0.28 11/4 32 13/4 44 27/16 62 1.09 0.49 1.09 0.49 11/2 40 115/16 49 211/16 68 1.44 0.65 1.44 0.65 2 50 21/4 57 31/4 83 2.85 1.29 2.85 1.29 21/2 65 211/16 68 37/8 98 4.00 1.81 4.00 1.81 3 80 31/16 78 41/2 114 6.06 2.75 6.06 2.75 4 100 313/16 98 511/16 144 10.53 4.78 10.53 4.78 1/2 x 3/8 15 x 10 11/16 27 19/16 40 0.23 0.10 0.23 0.10 3/4 x 1/2 20 x 15 13/16 30 13/4 44 0.32 0.15 0.32 0.15 1 x 3/4 25 x 20 13/8 35 21/16 52 0.54 0.24 0.54 0.24 11/4 x 1 32 x 25 19/16 40 25/16 59 0.86 0.39 0.86 0.39 11/4 x 3/4 32 x 20 17/16 37 21/4 57 0.75 0.34 0.75 0.34 11/2 x 11/4 40 x 32 113/16 47 29/16 65 1.18 0.54 1.18 0.54 11/2 x 1 40 x 25 15/8 41 21/2 64 1.08 0.49 1.08 0.49 2 x 11/2 50 x 40 2 51 215/16 75 1.85 0.84 1.85 0.84 C C J A q MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) q FIGURE 1106 (Straight) q FIGURE 1106R (Reducing) Street or Service Tee Size A J Unit Weight Black Galv. NPS DN in mm in mm lbs kg lbs kg 1⁄4 8 13⁄16 30 13⁄16 30 0.15 0.07 0.15 0.07 3⁄8 10 15⁄16 33 17⁄16 37 0.24 0.11 0.24 0.11 1⁄2 15 11⁄8 29 15⁄8 41 0.34 0.15 0.34 0.15 3⁄4 20 15⁄16 33 17⁄8 48 0.61 0.28 0.61 0.28 1 25 11⁄2 38 21⁄8 54 0.96 0.44 0.96 0.44 11⁄4 32 13⁄4 44 27⁄16 62 1.39 0.63 1.39 0.63 11⁄2 40 115⁄16 49 211⁄16 68 1.93 0.88 1.93 0.88 2 50 21⁄4 57 31⁄4 83 3.16 1.43 3.16 1.43 Size female run x male run x outlet Run Outlet Unit Weight A J A Black Galv. NPS DN in mm in mm in mm lbs kg lbs kg 11⁄4 x 1 x 11⁄4 32 x 25 x 32 13⁄4 44 25⁄16 59 13⁄4 44 1.34 0.61 1.34 0.61 FIGURE 1107 Cross Size A Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1⁄8 6 11⁄16 17 0.12 0.05 0.12 0.05 1⁄4 8 13⁄16 22 0.18 0.08 0.18 0.08 3⁄8 10 15⁄16 24 0.28 0.13 0.28 0.13 1⁄2 15 11⁄8 29 0.42 0.19 0.42 0.19 3⁄4 20 15⁄16 33 0.69 0.31 0.69 0.31 1 25 11⁄2 38 1.12 0.51 1.12 0.51 11⁄4 32 13⁄4 44 1.44 0.65 1.44 0.65 11⁄2 40 115⁄16 49 1.98 0.90 1.98 0.90 2 50 21⁄4 57 3.30 1.50 3.30 1.50 21⁄2 65 211⁄16 68 5.90 2.68 5.90 2.68 3 80 31⁄16 78 7.94 3.60 7.94 3.60 4 100 313⁄16 98 13.50 6.12 13.50 6.12 J A A A AA A q MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) q q FIGURE 1121 Coupling Size W Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1⁄8*6 15⁄16 24 0.06 0.03 0.06 0.03 1⁄4 8 11⁄16 27 0.09 0.04 0.09 0.04 3⁄8 10 13⁄16 30 0.13 0.06 0.13 0.06 1⁄2 15 15⁄16 33 0.20 0.09 0.20 0.09 3⁄4 20 11⁄2 38 0.30 0.14 0.30 0.14 1 25 111⁄16 43 0.48 0.22 0.48 0.22 11⁄4 32 115⁄16 49 0.75 0.34 0.75 0.34 11⁄2 40 21⁄8 54 1.00 0.45 1.00 0.45 2 50 21⁄2 64 1.45 0.66 1.45 0.66 21⁄2 65 27⁄8 73 2.40 1.09 2.40 1.09 3 80 33⁄16 81 3.30 1.50 3.30 1.50 4 100 311⁄16 94 5.72 2.59 5.72 2.59 * Offered in steel only. FIGURE 1124 Cap Size Unit Weight Black Galv. NPS DN lbs kg lbs kg 1⁄2 15 0.12 0.05 0.12 0.05 3⁄4 20 0.22 0.10 0.22 0.10 1 25 0.38 0.17 0.38 0.17 11⁄4 32 0.58 0.26 0.58 0.26 11⁄2 40 0.73 0.33 0.73 0.33 2 50 1.13 0.51 1.13 0.51 21⁄2 65 1.75 0.79 1.75 0.79 3 80 2.62 1.19 2.62 1.19 31⁄2 90 3.19 1.45 3.19 1.45 4 100 4.54 2.06 4.54 2.06 5 125 6.45 2.93 6.45 2.93 6 150 10.00 4.54 10.00 4.54 W MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) q q FIGURE 1104 45˚ Street Elbow Size C K Unit Weight Black Galv. NPS DN in mm in mm lbs kg lbs kg 1/8 6 11/16 17 7/8 22 0.06 0.03 0.06 0.03 1/4 8 3/4 19 15/16 24 0.10 0.05 0.10 0.05 3/8 10 13/16 22 1 25 0.14 0.06 0.14 0.06 1/2 15 7/8 22 11/8 29 0.20 0.09 0.20 0.09 3/4 20 1 25 15/16 33 0.33 0.15 0.33 0.15 1 25 11/8 29 17/16 37 0.52 0.24 0.52 0.24 11/4 32 15/16 33 111/16 43 0.85 0.39 0.85 0.39 11/2 40 17/16 37 17/8 48 1.22 0.55 1.22 0.55 2 50 111/16 43 21/4 57 1.92 0.87 1.92 0.87 FIGURE 1105 Straight Tee Size A Unit Weight Black Galv. NPS DN in mm lbs kg lbs kg 1/8 6 11/16 17 0.09 0.04 0.09 0.04 1/4 8 13/16 22 0.15 0.07 0.15 0.07 3/8 10 15/16 24 0.23 0.10 0.23 0.10 1/2 15 11/8 29 0.41 0.19 0.41 0.19 3/4 20 15/16 33 0.60 0.27 0.60 0.27 1 25 11/2 38 0.90 0.41 0.90 0.41 11/4 32 13/4 44 1.31 0.59 1.31 0.59 11/2 40 115/16 49 1.73 0.78 1.73 0.78 2 50 21/4 57 2.52 1.14 2.52 1.14 21/2 65 211/16 68 4.90 2.22 4.90 2.22 3 80 31/16 78 7.13 3.23 7.13 3.23 31/2 90 37/16 87 9.00 4.08 9.00 4.08 4 100 313/16 98 11.32 5.13 11.32 5.13 5 125 41/2 114 19.42 8.81 19.42 8.81 6 150 51/8 130 25.50 11.56 25.50 11.56 K C A A A MALLEABLE IRON FITTINGS Class 150 (Standard) FIGURE 1105R Reducing Tee Size X Y Z Unit Weight Black Galv. NPS DN NPS DN NPS DN in mm in mm in mm lbs kg lbs kg 1⁄8 6 1⁄8 6 1⁄4 8 3⁄4 19 3⁄4 19 3⁄4 19 0.12 0.05 0.12 0.05 1⁄4 8 1⁄4 8 1⁄8 6 3⁄4 19 3⁄4 19 3⁄4 19 0.13 0.06 0.13 0.06 3⁄8 10 15⁄16 24 15⁄16 24 7⁄8 22 0.19 0.09 0.19 0.09 3⁄8 10 1⁄4 8 1⁄4 8 7⁄8 22 13⁄16 22 15⁄16 24 0.19 0.09 0.19 0.09 3⁄8 10 15⁄16 24 15⁄16 24 15⁄16 24 0.21 0.10 0.21 0.10 3⁄8 10 1⁄4 8 7⁄8 22 7⁄8 22 15⁄16 24 0.21 0.10 0.21 0.10 1⁄2 15 11⁄16 27 11⁄16 27 11⁄16 27 0.27 0.12 0.27 0.12 1⁄2 15 1⁄4 8 1⁄2 15 11⁄8 29 15⁄16 24 11⁄8 29 0.29 0.13 0.29 0.13 3⁄8 10 3⁄8 10 11⁄16 27 1 25 11⁄16 27 0.28 0.13 0.28 0.13 1⁄2 15 11⁄8 29 11⁄16 27 11⁄8 29 0.33 0.15 0.33 0.15 1⁄2 15 1⁄4 8 1 25 1 25 1 25 0.27 0.12 0.27 0.12 3⁄8 10 11⁄16 27 11⁄16 27 11⁄16 27 0.30 0.14 0.30 0.14 3⁄4 20 11⁄4 32 11⁄4 32 13⁄16 30 0.45 0.20 0.45 0.20 1 25 13⁄8 35 13⁄8 35 11⁄4 32 0.55 0.25 0.55 0.25 3⁄4 20 1⁄4 8 3⁄4 20 15⁄16 33 11⁄8 29 15⁄16 33 0.45 0.20 0.45 0.20 3⁄8 10 3⁄8 10 11⁄8 29 15⁄16 24 11⁄8 29 0.36 0.16 –– 3⁄4 20 15⁄16 33 11⁄8 29 15⁄16 33 0.46 0.21 0.46 0.21 1⁄2 15 1⁄2 15 13⁄16 30 11⁄8 29 11⁄4 32 0.43 0.20 0.43 0.20 3⁄4 20 15⁄16 33 11⁄4 32 15⁄16 33 0.51 0.23 0.51 0.23 3⁄4 20 1⁄4 8 11⁄16 27 11⁄16 27 11⁄8 29 0.38 0.17 0.38 0.17 3⁄8 10 11⁄8 29 11⁄8 29 11⁄8 29 0.42 0.19 0.42 0.19 1⁄2 15 13⁄16 22 13⁄16 30 11⁄4 32 0.47 0.21 0.47 0.21 1 25 17⁄16 37 17⁄16 37 13⁄8 35 0.62 0.28 0.62 0.28 11⁄4 32 15⁄8 41 15⁄8 41 17⁄16 37 0.90 0.41 0.90 0.41 1 25 1⁄4 8 1 25 11⁄2 38 15⁄16 33 11⁄2 38 0.69 0.31 0.69 0.31 1⁄2 15 1⁄2 15 11⁄4 32 11⁄8 29 13⁄8 35 0.70 0.32 0.70 0.32 3⁄4 20 13⁄8 35 11⁄4 32 17⁄16 37 0.56 0.25 0.56 0.25 1 25 11⁄2 38 13⁄8 35 11⁄2 38 0.76 0.34 0.76 0.34 3⁄4 20 1⁄2 15 11⁄4 32 13⁄16 30 13⁄8 35 0.59 0.27 0.59 0.27 3⁄4 20 13⁄8 35 15⁄16 33 17⁄16 37 0.74 0.34 0.74 0.34 1 25 11⁄2 38 17⁄16 37 11⁄2 38 0.78 0.35 0.78 0.35 1 25 1⁄4 8 11⁄8 29 11⁄8 29 11⁄4 44 0.53 0.24 0.53 0.24 3⁄8 10 13⁄16 30 13⁄16 30 11⁄4 32 0.60 0.27 0.60 0.27 1⁄2 15 11⁄4 32 11⁄4 32 13⁄8 35 0.70 0.32 0.70 0.32 3⁄4 20 13⁄8 35 13⁄8 35 17⁄16 37 0.82 0.37 0.82 0.37 11⁄4 32 111⁄16 43 111⁄16 43 19⁄16 40 0.92 0.42 0.92 0.42 11⁄2 40 113⁄16 47 113⁄16 46 15⁄8 41 1.19 0.54 1.19 0.54 2 50 2 51 2 51 13⁄4 44 1.63 0.74 1.63 0.74 See additional sizes on following page. X Y Z q MALLEABLE IRON FITTINGS FIGURE 1105R Reducing Tee (Cont'd.) Size X Y Z Unit Weight Black Galv. NPS DN NPS DN NPS DN in mm in mm in mm lbs kg lbs kg 11⁄4 32 1⁄2 15 1 25 19⁄16 40 13⁄8 35 111⁄16 43 0.87 0.39 0.87 0.39 11⁄4 32 13⁄4 44 19⁄16 40 13⁄4 44 1.04 0.47 1.04 0.47 3⁄4 20 3⁄4 20 17⁄16 37 15⁄16 33 15⁄8 41 0.86 0.39 0.86 0.39 1 25 19⁄16 40 17⁄16 37 111⁄16 43 0.91 0.41 0.91 0.41 11⁄4 32 13⁄4 44 15⁄8 41 13⁄4 44 1.04 0.47 1.04 0.47 1 25 1⁄2 15 13⁄8 35 11⁄4 32 19⁄16 40 0.76 0.34 0.76 0.34 3⁄4 20 17⁄16 37 13⁄8 35 15⁄8 41 0.87 0.39 0.87 0.39 1 25 19⁄16 40 11⁄2 38 111⁄16 43 1.11 0.50 1.11 0.50 11⁄4 32 13⁄4 44 111⁄16 43 13⁄4 44 1.13 0.51 1.13 0.51 11⁄4 32 3⁄8 10 11⁄4 32 11⁄4 32 17⁄16 37 0.86 0.39 0.86 0.39 1⁄2 15 13⁄8 35 13⁄8 35 19⁄16 40 0.98 0.44 0.98 0.44 3⁄4 20 17⁄16 37 17⁄16 37 15⁄8 41 1.07 0.49 1.07 0.49 1 25 19⁄16 40 19⁄16 40 111⁄16 43 1.18 0.54 1.18 0.54 11⁄2 40 17⁄8 48 17⁄8 48 113⁄16 47 1.45 0.66 1.45 0.66 2 50 21⁄8 54 21⁄8 54 17⁄8 48 1.70 0.77 1.70 0.77 11⁄2 40 1⁄2 15 11⁄2 40 115⁄16 49 111⁄16 43 115⁄16 49 1.33 0.60 1.33 0.60 3⁄4 20 3⁄4 20 11⁄2 38 15⁄16 33 13⁄4 44 1.00 0.45 1.00 0.45 11⁄2 40 115⁄16 49 13⁄4 44 115⁄16 49 1.41 0.64 1.41 0.64 1 25 1 25 15⁄8 41 11⁄2 38 113⁄16 47 1.14 0.52 1.14 0.52 11⁄4 32 113⁄16 47 111⁄16 43 17⁄8 48 1.30 0.59 1.30 0.59 11⁄2 40 115⁄16 49 113⁄16 47 115⁄16 49 1.50 0.68 1.50 0.68 11⁄4 32 1⁄2 15 17⁄16 37 13⁄8 35 111⁄16 43 1.05 0.48 1.05 0.48 3⁄4 20 11⁄2 38 17⁄16 37 13⁄4 44 1.08 0.49 1.08 0.49 1 25 15⁄8 41 19⁄16 40 113⁄16 47 1.26 0.57 1.26 0.57 11⁄4 32 113⁄16 47 13⁄4 44 17⁄8 48 1.52 0.69 1.52 0.69 11⁄2 40 115⁄16 49 17⁄8 48 115⁄16 49 1.50 0.68 1.50 0.68 11⁄2 40 1⁄2 15 17⁄16 37 17⁄16 37 111⁄16 43 1.19 0.54 1.19 0.54 3⁄4 20 11⁄2 38 11⁄2 38 13⁄4 44 1.60 0.73 1.60 0.73 1 25 15⁄8 41 15⁄8 41 113⁄16 47 1.45 0.66 1.45 0.66 11⁄4 32 113⁄16 47 113⁄16 47 17⁄8 48 1.45 0.66 1.45 0.66 2 50 23⁄16 56 23⁄16 56 2 51 1.86 0.84 1.86 0.84 See additional sizes on previous and following page. X Y Z Class 150 (Standard) PF-6.13 MALLEABLE IRON FITTINGS Class 150 (Standard) FIGURE 1105R Reducing Tee (Cont'd.) Size X Y Z Unit Weight Black Galv. NPS DN NPS DN NPS DN in mm in mm in mm lbs kg lbs kg 2 50 1⁄2 15 2 50 21⁄4 57 17⁄8 48 21⁄4 57 2.15 0.98 2.15 0.98 3⁄4 20 2 50 21⁄4 57 115⁄16 49 21⁄4 57 2.00 0.91 2.00 0.91 1 25 2 50 21⁄4 57 2 51 21⁄4 57 2.14 0.97 2.14 0.97 11⁄4 32 11⁄4 32 17⁄8 48 13⁄4 44 21⁄8 54 1.72 0.78 1.72 0.78 11⁄2 40 2 51 17⁄8 48 23⁄16 56 1.85 0.84 1.85 0.84 2 50 21⁄4 57 21⁄8 54 21⁄4 57 2.20 1.00 2.20 1.00 11⁄2 40 1 25 13⁄4 44 15⁄8 41 2 51 1.57 0.71 1.57 0.71 11⁄4 32 17⁄8 48 113⁄16 47 21⁄8 54 1.76 0.80 1.76 0.80 11⁄2 40 2 51 115⁄16 49 23⁄16 56 1.95 0.88 1.95 0.88 2 50 21⁄4 57 23⁄16 56 21⁄4 57 2.24 1.02 2.24 1.02 2 50 1⁄2 15 11⁄2 38 11⁄2 38 17⁄8 48 1.65 0.75 1.65 0.75 3⁄4 20 15⁄8 41 15⁄8 41 2 51 1.87 0.85 1.87 0.85 1 25 13⁄4 44 13⁄4 44 2 51 1.76 0.80 1.76 0.80 11⁄4 32 17⁄8 48 17⁄8 48 21⁄8 54 2.35 1.07 2.35 1.07 11⁄2 40 2 51 2 51 23⁄16 56 2.55 1.16 2.55 1.16 21⁄2 65 25⁄8 67 25⁄8 67 23⁄8 60 3.50 1.59 3.50 1.59 21⁄2 65 11⁄2 40 2 50 23⁄8 60 23⁄16 56 25⁄8 67 3.43 1.56 3.43 1.56 21⁄2 65 211⁄16 68 21⁄2 64 211⁄16 68 3.80 1.72 3.80 1.72 2 50 2 50 23⁄8 60 21⁄4 57 25⁄8 67 3.28 1.49 3.28 1.49 21⁄2 65 211⁄16 68 25⁄8 67 211⁄16 68 4.10 1.86 4.10 1.86 21⁄2 65 3⁄4 20 13⁄4 44 13⁄4 44 25⁄16 59 2.72 1.23 2.72 1.23 1 25 17⁄8 48 17⁄8 48 23⁄8 60 2.85 1.29 2.85 1.29 11⁄4 32 21⁄16 52 21⁄16 52 27⁄16 62 3.36 1.52 3.36 1.52 11⁄2 40 23⁄16 56 23⁄16 56 21⁄2 64 3.46 1.57 3.46 1.57 2 50 23⁄8 60 23⁄8 60 25⁄8 67 3.65 1.66 3.65 1.66 3 80 3 76 3 76 213⁄16 73 5.82 2.64 5.82 2.64 3 80 2 50 2 50 21⁄2 64 21⁄4 57 27⁄8 73 4.50 2.04 4.50 2.04 3 80 31⁄8 79 27⁄8 73 31⁄8 79 5.80 2.63 5.80 2.63 21⁄2 65 2 50 21⁄2 64 23⁄8 60 27⁄8 73 4.80 2.18 4.80 2.18 21⁄2 65 213⁄16 73 211⁄16 68 3 76 5.80 2.63 5.80 2.63 3 80 3⁄4 20 17⁄8 48 17⁄8 48 25⁄8 67 4.03 1.83 4.03 1.83 1 25 2 51 2 51 25⁄8 67 4.13 1.87 4.13 1.87 11⁄4 32 23⁄16 56 23⁄16 56 23⁄4 70 4.50 2.04 4.50 2.04 11⁄2 40 25⁄16 59 25⁄16 59 213⁄16 73 5.18 2.35 5.18 2.35 2 50 21⁄2 64 21⁄2 64 27⁄8 73 5.70 2.59 5.70 2.59 21⁄2 65 213⁄16 73 213⁄16 73 3 76 6.09 2.76 6.09 2.76 4 100 3 80 4 100 313⁄16 98 35⁄8 92 313⁄16 98 10.40 4.72 10.40 4.72 4 100 11⁄2 40 21⁄2 65 21⁄2 65 33⁄8 86 7.47 3.39 7.47 3.39 2 50 23⁄4 70 23⁄4 70 37⁄16 87 8.39 3.80 8.39 3.80 21⁄2 65 31⁄16 78 31⁄16 78 31⁄2 89 9.60 4.35 9.60 4.35 3 80 35⁄16 84 35⁄16 84 35⁄8 92 11.02 5.00 11.02 5.00 See additional sizes on previous page. X Y Z Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) PF-6.13 MALLEABLE IRON FITTINGS Class 150 (Standard) Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/8" (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) FIGURE 1125 Reducer Size M Unit Weight Black Galv. NPS DN NPS DN in mm lbs kg lbs kg 1⁄4 8 1⁄8 6 1 25 0.07 0.03 0.07 0.03 3⁄8 10 1⁄8 6 11⁄8 29 0.11 0.05 0.11 0.05 1⁄4 8 0.11 0.05 0.11 0.05 1⁄2 15 1⁄8 6 11⁄4 32 0.14 0.06 0.14 0.06 1⁄4*8 0.15 0.07 0.15 0.07 3⁄8 10 0.17 0.08 0.17 0.08 3⁄4 20 1⁄8 6 17⁄16 37 0.24 0.11 0.24 0.11 1⁄4 8 0.22 0.10 0.22 0.10 3⁄8 10 0.25 0.11 0.25 0.11 1⁄2*15 0.27 0.12 0.27 0.12 1 25 1⁄4 8 111⁄16 43 0.35 0.16 0.35 0.16 3⁄8 10 0.35 0.16 0.35 0.16 1⁄2 15 0.39 0.18 0.39 0.18 3⁄4*20 0.43 0.20 0.43 0.20 11⁄4 32 1⁄2 15 21⁄16 52 0.61 0.28 0.61 0.28 3⁄4 20 0.64 0.29 0.64 0.29 1 25 0.68 0.31 0.68 0.31 11⁄2 40 1⁄2 15 25⁄16 59 0.78 0.35 0.78 0.35 3⁄4 20 0.88 0.40 0.88 0.40 1 25 0.88 0.40 0.88 0.40 11⁄4 32 0.90 0.41 0.90 0.41 2 50 1⁄2 15 213⁄16 73 1.30 0.59 1.30 0.59 3⁄4 20 1.34 0.61 1.34 0.61 1 25 1.40 0.63 1.40 0.63 11⁄4 32 1.53 0.69 1.53 0.69 11⁄2 40 1.55 0.70 1.55 0.70 21⁄2 65 1 25 31⁄4 83 2.12 0.96 2.12 0.96 11⁄4 32 2.09 0.95 2.09 0.95 11⁄2 40 2.09 0.95 2.09 0.95 2 50 2.51 1.14 2.51 1.14 3 80 1 25 311⁄16 94 3.16 1.43 3.16 1.43 11⁄4 32 2.99 1.36 2.99 1.36 11⁄2 40 3.30 1.50 3.30 1.50 2 50 3.25 1.47 3.25 1.47 21⁄2 65 3.31 1.50 3.31 1.50 31⁄2 90 2 50 4 102 4.32 1.96 4.32 1.96 21⁄2 65 4.72 2.14 4.72 2.14 3 80 4.99 2.26 4.99 2.26 4 100 11⁄2 40 43⁄8 111 4.90 2.22 4.90 2.22 2 50 5.10 2.31 5.10 2.31 21⁄2 65 5.93 2.69 5.93 2.69 3 80 6.55 2.97 6.55 2.97 31⁄2 90 6.30 2.86 6.30 2.86 5 125 4 100 49⁄16 116 9.57 4.34 9.57 4.34 6 150 4 100 413⁄16 124 10.30 4.67 10.30 4.67 M * Sizes 1/2 x 1/4 , 3/4 x 1/2 and 1 x 3/4 do not have bands at the reducing end. q MALLEABLE IRON FITTINGS PF-11.16 Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES 3⁄8" (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 Sizes 1⁄4"–1" (6–25 mm) Sizes 11⁄4"–2" (32–51 mm) Sizes 21⁄2"–3" (64–76 mm) (°F)(°C)psi bar psi bar psi bar psi bar -20° to 150° -28.9° to 65.6° 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 200°93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 250°121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 300°148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350°176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 400°204.4 ––935 64.5 750 51.7 560 38.6 450°232.2 ––725 50.0 600 41.4 475 32.8 500°260.0 ––510 35.2 450 31.0 385 26.5 550°287.8 ––300 20.7 300 20.7 300 20.7 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil Sales Representative. Standards and Specifications Dimensions Material Galvanizing *Thread Pressure Rating MALLEABLE IRON FITTINGS Class 150/PN 20 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 Class 300/PN 50 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 MALLEABLE IRON UNIONS Class 150/PN 20 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 250 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 300/PN 50 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 * ASTM B 633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard. Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (°F) (°C)psi bar psi bar psi bar -20° to 150° -28.9° to 65.6° 300 20.7 500 34.5 600 41.4 200°93.3°265 18.3 455 31.4 550 37.9 250°121.1°225 15.5 405 27.9 505 34.8 300°148.9°185 12.8 360 24.8 460 31.7 350°176.7°150 10.3 315 21.7 415 28.6 400°204.4°110 7.6 270 18.6 370 25.5 450°232.2°75 5.2 225 15.5 325 22.4 500°260.0°––180 12.4 280 19.3 550°287.8°––130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a “holefinder” locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are s ervices for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a l isting of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. 11.02_1 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_L STYLES 920 AND 920N STYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO DIMENSIONS GROOVED OUTLET W ZY V Size Style No. Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg 2 × 1/2 (a) ¤ 920N 500 1.50 2.00 2.53 —1.61 5.35 2.75 3.1 —50 15 3450 38.1 51 64 41 136 70 1.5 3/4 (a) ¤ 920N 500 1.50 1.97 2.53 —1.61 5.35 2.75 3.1 —20 3450 38.1 50 64 41 136 70 1.5 1 (a) ¤920N 500 1.50 1.85 2.53 —1.61 5.35 2.75 3.0 —25 3450 38.1 47 64 41 136 70 1.4 1 1/4 (a) †¤920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) †¤920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 1/2 × 1/2 (a) §¤920N 500 1.50 2.21 2.74 —1.82 5.64 2.75 3.0 —65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) §¤920N 500 1.50 2.18 2.74 —1.82 5.64 2.75 3.0 —20 3450 38.1 55 70 46 143 70 1.4 1 (a) §¤920N 500 1.50 2.06 2.74 —1.82 5.64 2.75 2.9 —25 3450 38.1 52 70 46 143 70 1.4 1 1/4 † (a) ¤920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 † (a) ¤920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 76.1 × 1/2 (a)920N 300 1.50 2.22 2.75 —2.25 6.46 3.18 3.9 —15 2065 38.1 56 70 57 164 81 1.8 3/4 (a)920N 300 1.50 2.19 2.75 —2.25 6.46 3.18 3.9 —20 2065 38.1 56 70 57 164 81 1.8 1 (a) 920N 300 1.50 2.07 2.75 —2.25 6.46 3.18 3.8 —25 2065 38.1 53 70 57 164 81 1.7 1 1/4 (a) ¤920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a) ¤920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 × 1/2 (a) ¤920N 500 1.50 2.52 3.05 —2.28 6.15 2.75 3.4 —80 15 3450 38.1 64 78 58 156 70 1.6 3/4 (a) ¤920N 500 1.50 2.49 3.05 —2.28 6.15 2.75 3.4 —20 3450 38.1 63 78 58 156 70 1.6 1 (a)920N 500 1.50 2.38 3.06 —2.28 6.15 2.75 3.3 —25 3450 38.1 61 78 58 156 70 1.6 1 1/4 (a) †¤920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32 (b)3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) †¤920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40 (b)3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) ¤920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 1/2 × 2 920N 500 2.50 3.00 —3.75 2.44 6.72 3.88 —3.8 90 50 3450 63.5 76 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_2 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_L DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No. Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 2 4 × 1/2 (a) ¤920N 500 1.50 3.03 3.56 —2.69 7.01 2.75 3.7 —100 15 3450 38.1 77 90 68 178 70 1.8 3/4 (a) ¤920N 500 1.50 3.00 3.56 —2.69 7.01 2.75 3.7 —20 3450 38.1 76 90 68 178 70 1.8 1 (a) ¤920N 500 1.50 2.88 3.56 —2.69 7.01 2.75 3.6 —25 3450 38.1 73 90 68 178 70 1.8 1 1/4 (a) †¤920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32 (b)3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) †¤920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40 (b)3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) †¤920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2 1/2 (a) †920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 —4.00 2.69 7.34 4.63 —6.4 3450 69.9 73 102 68 186 118 2.9 3 (a) †920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 108.0 × 1 1/4 (a)¤920N 500 1.75 3.08 3.78 —2.63 7.64 3.05 5.0 —32 3450 44.5 78 96 67 194 78 2.3 1 1/2 (a)¤920N 500 2.00 3.28 4.00 —2.63 7.64 3.25 5.0 —40 3450 50.8 83 102 67 194 83 2.3 2 (a)920N 500 2.50 3.25 4.00 —2.63 7.64 4.00 4.0 —50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a)920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 × 1 1/2 (a) †920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) †920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 2 1/2 (a) †920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm ¤920 500 2.75 3.75 —4.75 3.16 9.70 4.63 —8.0 3450 69.9 95 121 80 246 118 3.6 3 (a) †920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 133.0 × 2 920N 500 2.50 3.75 4.50 —3.17 8.00 3.88 8.0 —50 3450 63.5 95 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 —3.00 9.46 5.31 8.0 —80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_3 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_L FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. CV and Kv Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for CV /Kv Values: 1 2 Exaggerated for clarity OUTLET SIZE Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213, Sec. 16) (C = 120)ŧ FT CV/KV Values NOMINAL DIAMETER In/mm ACTUAL O.D. In/mm GROOVED THREADED GROOVED THREADED 1/2 0.840 -2 -11 15 21.3 9.4 3/4 1.050 -4 -16 20 26.7 13.7 1 1.315 -8 -21 25 33.7 1.8 1 1/4 1.660 5 1/2 6 50 48 32 42.7 42.9 41.1 1 1/2 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 9 10 1/2 112 104 50 60.3 96 89.1 2 1/2 2.875 20 12 1/2 119 150 65 73.0 102 128.5 3.000 16*-161 -76.1 mm 76.1 138.1 3 3.500 14 15 1/2 249 237 80 88.9 213.4 203.1 4 4.500 20 22 421 401 100 114.3 360.8 343.6 ŧ Hazen-Williams coefficient of friction is 120.* Pipe with a wall thickness of 0.165in./4.2mm. 11.02_6 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_L TAB 2 SPRINKLERS Series DS-C Dry Type Sprinklers 5.6K Concealed Pendent Standard and Quick Response, Standard Coverage Page 1 of 8 NOVEMBER 2019 TFP515 IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description TYCO Series DS-C Dry Type Sprin- klers, 5.6K Concealed Pendent, Stan- dard (5 mm Bulb) and Quick Response (3 mm Bulb) and Standard Coverage, are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. This type of sprinkler is typi- cally used to provide a sprinkler drop from an unheated attic into an area where aesthetics is a concern, such as nursing homes, restaurants, and schools. Each unit includes a Cover Plate Assembly that conceals the sprinkler operating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assemblies allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the Sprinkler provides for 1/2 in. (12,7 mm) of vertical adjustment. Series DS-C Sprinklers are shipped with a Disposable Protective Cap. The Pro- tective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board and ceiling tiles by gently pushing the ceiling product against the Protective Cap. When the ceiling instal- lation is complete the Protective Cap is removed and the Cover Plate Assembly installed. NOTICE Series DS-C Dry Type Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-C Dry Type Concealed Pendent Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Sprinkler Identification Numbers (SINs) TY3535 - 3 mm Bulb TY3555 - 5 mm Bulb Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 352-01-E-2 Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1 in. NPT (Standard Order) ISO 7-R1 Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Ratings 155°F (68°C) Sprinkler with 139°F (59°C) Cover Plate 200°F (93°C) Sprinkler with 165°F (74°C) Cover Plate Adjustment 1/2 in. (12,7 mm) Finishes See Ordering Procedure section Physical Characteristics Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Yoke .......................Stainless Steel Casing .............Galvanized Carbon Steel Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Bulb Seat . . . . . . . . . . . . . . . . . . . Stainless Steel Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Guide Tube . . . . . . . . . . . . . . . . . Stainless Steel Water Tube . . . . . . . . . . . . . . . . . Stainless Steel Spring .......Stainless Steel Gasketed Spring Plate Seal ........Beryllium Nickel w/TEFLON Support Cup ............Chrome Plated Steel Guide Pins . . . . . . . . . . . . . . . . . . Stainless Steel Compression Screw . . . . . . . . . . . . . . . . . Brass Cover Plate . . . . . . . . . . . . . . . . . . . . . . . . .Brass Retainer . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Ejection Spring . . . . . . . . . . . . . . Stainless Steel TFP515 Page 2 of 8 Operation When TYCO Series DS-C Dry Type Concealed Pendent Sprinklers is in service, water is prevented from enter- ing the assembly by the Plug with Gas- keted Spring Plate Seal (see Figure 1) in the Inlet of the Sprinkler. When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler Assembly. At this point the Deflector supported by the Guide Pins drops down to its opera- tional position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Gasketed Spring Plate Seal, from the Inlet, allowing the sprinkler to activate and flow water. INSERT FRAME BULB DEFLECTOR GUIDE PIN VENT HOLE CASING GUIDE TUBE SPRING INLET YOKE INLET BAND WATER TUBE BULB SEAT COMPRESSION SCREW EJECTION SPRING COVER PLATE SOLDER TAB RETAINER WITH THREAD DIMPLES DEFLECTOR (DROPPED POSITION) PLUG WITH GASKETED SPRING PLATE SEAL SUPPORT CUP WITH ROLL FORMED THREADS THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING COVER PLATE RETAINER ASSEMBLY SPRINKLER SUPPORT CUP ASSEMBLY FIGURE 1 SERIES DS-C STANDARD COVERAGE DRY-TYPE CONCEALED PENDENT SPRINKLER ASSEMBLY TFP515 Page 3 of 8 COVER PLATE RETAINER ASSEMBLY SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING 2-1/2" DIA. (63,5 mm) SPRINKLER SUPPORT CUP ASSEMBLY 1/2" (12,7 mm) THREADED ADJUSTMENT ORDER LENGTHS: 5" (127,0 mm) to 48" (1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF CEILING, RETAINING RING MOUNTING SURFACE 3/16" to 11/16" (4,8 to 17,5 mm) REFERENCE 3/16" (4,8 mm)FACTORY PRESET GAP 3/32" (2,4 mm) DEFLECTOR IN DROPPED POSITION 3-1/4" DIA. (82,6 mm) 2-1/2" DIA. (63,5 mm) CLEARANCE HOLE ACCEPTS 1/2" SOCKET DRIVE ALIGN ARROWS WITH FRAME ARMS 7/8" (23 mm) SQUARE SUPPORT CUP FRAME ARM FIGURE 2 SERIES DS-C STANDARD COVERAGE DRY-TYPE CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS FIGURE 3 DISPOSABLE PROTECTIVE CAP FIGURE 4 RFII SPRINKLER WRENCH TFP515 Page 4 of 8 Design Criteria TYCO Series DS-C 3 mm bulb-type Dry Type Concealed Pendent Sprin- klers (TY3535) are UL and C-UL Listed as quick response, standard spray sprinklers for use in accordance with the current NFPA standard. Series DS-C 5 mm bulb-type Dry Type Concealed Pendent Sprinklers (TY3555) are UL and C-UL Listed as standard response, standard spray sprinklers for use in accordance with the current NFPA standard. Series DS-C Dry Type Sprinklers are only listed when installed with Series RFII Concealed Cover Plates having a factory-applied painted or metallic finish. Series DS-C Dry Type Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Sprinkler Fittings Install 1 inch NPT Series DS-C Dry Type Concealed Pendent Sprinklers in the 1 in. NPT outlet or run of the following fittings: • malleable or ductile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-C Dry Type Concealed Pendent Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged, as shown in Figures 5 and 6. Install Series DS-C Dry-Type Sprinklers in the tee run or branch outlet. The configuration shown in Figure 5 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry Type Sprinkler has the minimum exposure length depicted in Figure 7. See the Exposure Length section. For wet pipe system installations of 1 in. NPT Series DS-C Dry Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1 in. x 1 in. NPT Female Adapter (P/N 80145) • 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2 1/2 in. reducing tee when locating Series DS-C Dry Type Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 6 to assure complete water drainage from above Series DS-C Dry Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install Series DS-C Dry Type Sprinklers into any other type fitting. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Type Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table A to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 7 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Do not attempt to add additional insula- tion around the barrel in the heated area as a method to minimize condensation. This will reduce the calculated “Expo- sure Length”. Clearance Space In accordance with NFPA 13, where dry sprinklers are connected to wet pipe sprinkler systems protecting insulated freezer structures, the clearance space around the sprinkler barrel of Dry Type Sprinklers must be sealed. Due to tem- perature differences between two areas, the potential for the formation of con- densation in the sprinkler and subse- quent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figure 8, will provide the recommended seal. NOTICE For applications where a bore greater than 1 3/4 in. in diameter has been cut through the entire height of an insulated freezer ceiling creating a cavity above the sprinkler support cup (see Figure 8), the cavity must not be filled. TFP515 Page 5 of 8 Installation TYCO Series DS-C Dry Concealed Pendent Sprinklers must be installed in accordance with this section. Series DS-C Dry Type Concealed Pendent Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. See the Design Criteria section for other important requirements regarding piping design and sealing of the clearance space around the Sprin- kler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 lb-ft (26,8 to 40,2 N·m). Higher levels of torque may distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler Assembly by under or over-tightening the Sprinkler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler in the pendent position with the centerline of the sprinkler perpendicular to the mounting surface. Step 2. With a non-hardening pipe- thread sealant such as TEFLON pipe- thread sealant applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing, see Figure 1. • the RFII Sprinkler Wrench on the wrench flat, see Figure 4. Apply the wrench recess of the RFII Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes neces-sary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. When using the RFII Sprinkler Wrench, temporarily remove the Protective Cap. Replace the Protec- tive Cap (see Figure 4) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Pro- tective Cap. As long as the Protective Cap remains in place, the system is considered to be “Out of Service”. Step 4. After installing the ceiling and applying a ceiling finish, with the 2 1/2 in. (63,5 mm) diameter hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 5. Screw on the Cover Plate/ Retainer Assembly until the Retainer (see Figure 2) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/ Retainer Assembly cannot be engaged sufficiently to contact the ceiling, repo- sition the Sprinkler Fitting. Ambient TemperatureExposed to Discharge End of Sprinkler Temperatures for Heated Areaa 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length, Inches (mm)b 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C)4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C)14 (355)4 (100)1 (25) -20°F (-29°C)14 (355)6 (150)3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C)20 (510)10 (255)6 (150) -60°F (-51°C)20 (510)10 (255)6 (150) NOTES: a. For protected area temperatures that occur between values listed above, use the next cooler temperature b. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph) TABLE A EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS TFP515 Page 6 of 8 Care and Maintenance TYCO Series DS-C Dry Type Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (see Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole indicate potential leakage past the Inlet seal and the need to remove the sprin- kler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protection system control valve and the system drain before removing the sprinkler. When properly installed, there is a nominal 3/16 in. (4,8 mm) air gap between the lip of the Cover Plate and the ceiling, see in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb, see Installation Section. If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. SIDE OUTLET PLUGGED TO WET SYSTEM FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLERDSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 INTENDED FOR FREEZER STRUCTURES FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER AREA SUBJECT TO FREEZING (SEE DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE 2-1/2" DIA. (63,5 mm) CLEARANCE HOLE DSB-2 BOOT DS-C DRY PENDENT CONCEALED SPRINKLER FIGURE 5 SPRINKLER FITTING HEATED AREA FIGURE 6 SPRINKLER FITTING UNHEATED AREA FIGURE 7 EXPOSURE LENGTH FIGURE 8 MODEL DSB-2 DRY SPRINKLER BOOT WITH DRY-TYPE SPRINKLER TFP515 Page 7 of 8 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and Part Number (P/N). Dry Type Sprinkler Assemblies When ordering 5.6 K-Factor Series DS-C Standard Coverage Dry Type Concealed Pendent Sprinklers, specify the following information: • SIN Quick Response TY3535 or Standard Response TY3555 • Temperature Rating • Order Length Dry Type Sprinklers are furnished based upon Order Length as measured from the face of the ceiling to the face of the sprinkler fitting, see Figure 2. After the measurement is taken, round it to the nearest 1/4 in. increment. • Inlet Thread Connection 1 in. NPT or ISO 7-R1 • Part Number from Table B P/N * 60 – XXX – 1 – XXX Note * Use Prefix “I” for ISO 7-R1 Connection (for example, I-60-461-1-180). ** Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figure 2, for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the near- est 1/4 in. increment. Separately Ordered Cover Plate Specify: Series RFII Concealed Cover Plate with (specify) temperature rating, (specify) finish, P/N (specify): 139°F (59°C) Cover Plate for use with 155°F (68°C) Sprinkler Grey White (RAL9002). . . . . . . . . . 56-792-0-135 Brass . . . . . . . . . . . . . . . . . . . . . . . .56-792-1-135 Pure White (RAL9010)*. . . . . . . . . .56-792-3-135 Signal White (RAL9003). . . . . . . . .56-792-4-135 Jet Black (RAL9005). . . . . . . . . . . 56-792-6-135 Chrome . . . . . . . . . . . . . . . . . . . . . 56-792-9-135 Custom . . . . . . . . . . . . . . . . . . . . . 56-792-X-135 165°F (74°C) Cover Plate for use with 200°F (93°C) Sprinkler Grey White (RAL9002). . . . . . . . . . 56-792-0-165 Brass . . . . . . . . . . . . . . . . . . . . . . . .56-792-1-165 Pure White (RAL9010)*. . . . . . . . . .56-792-3-165 Signal White (RAL9003). . . . . . . . .56-792-4-165 Jet Black (RAL9005). . . . . . . . . . . 56-792-6-165 Chrome . . . . . . . . . . . . . . . . . . . . . 56-792-9-165 Custom . . . . . . . . . . . . . . . . . . . . . 56-792-X-165 * Eastern Hemisphere Sales Only Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one Boot, two Strap Ties, and 1/3 oz. of Adhe- sive (a sufficient quantity for installing one boot), refer to Technical Data Sheet TFP591 for complete information. SIN 46 Quick Response (3 mm Bulb)TY3535 86 Standard Response (5 mm Bulb)TY3555 TEMPERATURE RATING 1 155°F (68°C) 3 200°F (93°C) ORDER LENGTH** 055 5.50 in. 082 8.25 in. 180 18.00 in. 187 18.75 in. 372 37.25 in. 480 48.00 in. TABLE B SERIES DS-C STANDARD COVERAGE DRY-TYPE CONCEALED PENDENT SPRINKLER PART NUMBER SELECTION TAB 3 HANGER Pipe Hangers Pi p e H a n g e r s 23 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions TOLCO Fig. 200 - “Trimline” Adjustable Band Hanger TOLCO Fig. 200F - “Trimline” Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCO Fig. 200C - “Trimline” Adjustable Band Hanger with Plastic Coated TOLCO Fig. 200S - “Trimline” Adjustable Band Hanger with Removable Nut (For sizes 1" thru 2") Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • 1/2" (15mm) thru 2" (50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes keep nut from separating with hanger. Hanger is easily installed around pipe. • 1/2" (15mm), 3/4" (20mm), and 21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. • For 1/2" (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts order Fig. 200S Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Part number and pipe size ** Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-11/2 or 200M10-11/2 † M8 rod size is not UL Listed or FM Approved A B D Fig. 200-1 to 200-2 Fig. 200-1/2 & 200-3/4 Fig. 200-21/2 to 200-8 Pipe Size Rod Size A B D Max. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 M8† or M10 31/8" (79.4) 25/8" (66.7) 111/32" (34.1) 400 (1.78) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 M8† or M10 31/8" (79.4) 21/2" (63.5) 11/16" (27.0) 400 (1.78) 11 (5.0) 200-1 1" (25) 3/8"-16 M8† or M10 33/8" (85.7) 25/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 M8† or M10 33/4" (94.0) 27/8" (73.0) 15/32" (29.3) 400 (1.78) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 M†8 or M10 37/8" (98.4) 27/8" (73.0) 13/16" (30.2) 400 (1.78) 14 (6.4) 200-2 2" (50) 3/8"-16 M8† or M10 41/2" (114.3) 39/50" (80.8) 13/16" (30.2) 400 (1.78) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 M10 55/8" (142.9) 41/8" (104.7) 17/16" (36.5) 600 (2.67) 27 (12.3) 200-3 3" (75) 3/8"-16 M10 57/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) 200-31/2 31/2" (90) 3/8"-16 M10 73/8" (187.3) 51/4" (133.3) 23/16" (55.6) 600 (2.67) 34 (15.6) 200-4 4" (100) 3/8"-16 M10 73/8" (187.3) 5" (127.0) 13/8" (34.9) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"-13 M12 91/8" (231.8) 61/4" (158.7) 311/32" (84.9) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"-13 M12 101/8" (257.2) 63/4" (171.4) 27/32" (56.3) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"-13 M12 131/8" (333.4) 83/4" (222.2) 37/32" (81.7) 1250 (5.56) 136 (62.3) Fig. 200C 200C-11/2 shown Fig. 200F 200F-11/2 shown Fig. 200 & Fig. 200S shown with non-captured nut Fig. 200 shown with captured nut 1" thru 2" sizes only A Overall Height B Center of pipe to top of knurled hanger rod nut. D Top of pipe to bottom of hanger rod nut. †† Be a m C l a m p s Beam Clamps 14 B-Line series Fire Protection SolutionsEaton Size Range: Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - 3/8"-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8"-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2"-13 rod will support thru 8" (200mm) pipe Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65-1/2 1/2"-13 11/2" (38.1) 3/4" (19.0) 1" (25.4) 9/16" (14.3) 65-5/8 5/8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) 9/16" (14.3) Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 65-1/2 11/4" (31.7) 55 (24.9) 65-5/8 11/4" (31.7) 55 (24.9) Part For Approx. Wt/100 No. Rod Size Lbs. (kg) 65XT 3/8"-16 28.0 (12.7) TOLCO Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening TOLCO Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening B F E A C D Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (100mm) pipe. Designed to meet or exceed requirements of FM DS 2-0 and NFPA 13. 3/4" (19.0) 19/16" (39.7) 1" (25.4) 7/8" (22.2)13/8" (34.9) Set Screw and Locknut Included Set Screw and Locknut Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. www.tolco.com Fig. 69 - Beam Clamp Retaining Strap Size Range — 3/8” thru 7/8” rod by 4” thru 16” length.* Material — Pre-Galvanized Steel Function — To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note — Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Pre-Galvanized Order By — Figure number, type, length “B” and rod size being used with beam clamp Note — Minimum return on Strap: 1”. Dimensions • Weights Type Rod Size A Hole Size B 1 3/8 7/16 Specify 1/2 9/16 Specify 2 5/8 11/16 Specify 3/4 13/16 Specify 3 3/8 - 7/8 Specify Specify *Longer lengths are available, consult factory. COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Th r e a d e d Ac c e s s o r i e s Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) B3205L - Threaded Rod (right & left hand threads) ATR - All Threaded Rod 120” (3.05m)Lengths Fig. 99 - All Threaded Rod Cut To Length Size Range:3/8"-16 thru 3"-4 rod Material:Steel Function:Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature:750°F (399°C) Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F (343°C)750°F (399°C) Part No.A in. (mm)Lbs. (kN)Lbs. (kN) B3205-3/8 x 'L'3/8"-16 2 1/2"(63.5)730 (3.25)572 (2.54) B3205-1/2 x 'L'1/2"-13 2 1/2"(63.5)1350 (6.00)1057 (4.70) B3205-5/8 x 'L'5/8"-11 2 1/2"(63.5)2160 (9.61)1692 (7.52) B3205-3/4 x 'L'3/4"-10 3"(76.2)3230 (14.37)2530 (11.25) B3205-7/8 x 'L'7/8"-9 3 1/2"(88.9)4480 (19.93)3508 (15.60) B3205-1 x 'L'1"-8 4"(101.6)5900 (26.24)4620 (20.55) B3205-11/8 x 'L'11/8"-7 4 1/2"(114.3)7450 (33.14)5830 (25.93) B3205-11/4 x 'L'11/4"-7 5"(127.0)9500 (42.25)7440 (33.09) B3205-11/2 x 'L'11/2"-6 6"(152.4)13800 (61.38)10807 (48.07) B3205-13/4 x 'L'13/4"-5 7"(177.8)18600 (82.73)14566 (64.79) B3205-2 x 'L'2"-41/2 8"(203.2)24600 (109.42)19625 (87.29) B3205-21/4 x 'L'21/4"-41/2 9"(228.6)32300 (143.67)25295 (112.51) B3205-21/2 x 'L'21/2"-4 10"(254.0)39800 (177.03)31169 (138.64) B3205-23/4 x 'L'23/4"-4 11"(279.4)49400 (219.73)38687 (172.08) B3205-3 x 'L'3"-4 12"(304.8)60100 (267.32)47066 (209.35) Part No. - Size x Length Threads Recommended Load Approx. Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN)Lbs. (kg) ATR 1/4” x 120 99- 1/4” x length 20 240 (1.07)12 (5.44) ATR 3/8” x 120 99-3/8” x length 16 730 (3.24)29 (13.15) ATR 1/2” x 120 99-1/2” x length 13 1350 (6.00)53 (24.04) ATR 5/8” x 120 99-5/8” x length 11 2160 (9.60)89 (40.37) ATR 3/4” x 120 99-3/4” x length 10 3230 (14.37)123 (55.79) ATR 7/8” x 120 99-7/8” x length 9 4480 (19.93)170 (77.11) ATR 1” x 120 99-1” x length 8 5900 (26.24)225 (102.06) ATR 11/8” x 120 99-11/8” x length 7 7450 (33.14)280 (127.01) ATR 11/4” x 120 99-11/4” x length 7 9500 (42.25)351 (159.21) ATR 11/2” x 120 99-11/2” x length 6 13800 (61.38)510 (231.33) 238 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports TL TL Specify Length ‘L’ A Thread Size Size Range:3/8"-16 thru 11/2"-6 rod in 120” (3.05m)lengths or cut to length Material:Steel Maximum Temperature:750°F (399°C) Finish:Plain. Contact customer service for alternative finishes and materials. Order By:Part number, rod diameter and finish