Crystal Springs - Lot 6 - Site Plans
s
S88°53'46"W 91.00'
S1
°
0
6
'
1
4
"
E
4
0
.
0
0
'
N88°53'46"E 91.00'
N1
°
0
6
'
1
4
"
W
4
0
.
0
0
'
STEP TANK
TSS
PORCH
TC
E
SILT FENCE
SS C/O
WATER
GAS
POWER
10' UTILITY EASEMENT
CLEARING LIMITS SEWER
SFSFSFSFSFSFSFSFSFSFSFSF
SF
SF
SF
SF
SF
SF SF SF SF SF SF SF SF SF SF SF SF
ooooooooooo
o
o
o
o
o
o o o o o o o o o o o
6'
CONTROL PANEL
STORM C/O
STORM
SD
20' L X 3' W X 3' D
INFILTRATION TRENCH
(60 S.F. BOTTOM)
RESIDENTIAL
SEDIMENT CONTROL
STRUCTURE
SL
E
E
V
E
STEP TANK
W/ H20 LID
2190A-2
7'
5'5'
5'
25'
25'
5'
5'
15'
6'
16
'
-
4
"
25'41'25'
5'
30
'
5'
25'40'11'15'
30
'
51'
10
'
10'
10
'
12'
CITY OF YELM
THURSTON COUNTY
PARCEL# XXX - LOT 6
9425 Chief Leschi St SE
YELM, WA. 98597
WG 01/17/2025
0 5 10 20
SCALE: 1"=10'
CRYSTAL SPRINGS
LOT-6
CH
I
E
F
L
E
S
C
H
I
S
T
S
E
LEGEND
EXISTING
SILT FENCE
CONCRETE
WATER METER
FM
W
SEWER
POWER
WATER
STORM
GAS
PROPOSED
SF
510 CONTOURS
BOUNDARY
ROOF
FOUNDATION
SEWER CONNECTION
POINT
EXISTING
RD
PROPOSED
ROOF DRAIN
STREET LIGHT
S
NOTES:
1. FRONT PORCH FOUNDATION AND STEP
TANK LOCATION SHALL BE STAKED
OUT FOR SET BACK INSPECTION.
2. STEP TANK MODEL
ORENCO PRELOS 1000
CONTACT INFO
MEGAN: (253) 256-8748
P.O. BOX 73790
PUYALLUP, WA 98373
PH: (253) 848-0820
IMPERVIOUS LOT AREA TABLE:
PROPOSED AREA:
ROOF AREA = 1,691 S.F.
SIDEWALK/DRIVEWAY = 482 S.F.
TOTAL = 2,173 S.F.
LOT AREA
3,640 S.F.