Loading...
Energy Code WorksheetWSU Code Compliance Calculator, WSEC 2018 Project Information Messages / Comments * Plan - 2190 A Elevation Review required for custom entries: - Doors City of Yelm UA Reduction = 8.93, Proposed UA is better than baseline by 3% Contact Information Soundbuilt Homes Window area is 11% of floor area PO Box 73790 - Puyallup, WA 98373 Whole House Mechanical Ventilation Airflow Rate: 40 CFM with Run Time Percent of 100%, Balanced, Distributed 253-848-0820 Maximum allowable total measured duct leakage: 175 CFM25 ANALYSIS SET UP What code compliance pathway are you using? Project Building Type? Occupancy Type? Code Version? WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/O Classification:Medium Dwelling Unit -- 2190 sq. ft. Baseline Description: Code Baseline - Baseline and proposed window areas are equal. About Your Selection:Up to 15 sf exempt window and 24 sf exempt door allowable RESULTS - Comparison of Baseline and Proposed Design ** Component Performance, R occupancies U *Area UA Area UA Doors U =0.300 102 30.5 102 24.6 Overhead Glazing U =0.500 0 0.0 0 0.0 Vertical Glazing U =0.300 234 70.2 234 70.2 Flat/Vaulted Ceilings U =0.024 1,386 33.3 1,386 34.7 Wall (above grade) U =0.056 2,184 122.3 2,184 117.9 Floors over Crawlspace U =0.029 1,386 40.2 1,386 40.2 Slab on Grade F =0.540 0 0.0 0 0.0 Below Grade Wall U =N/A 000.0 Below Grade Slab F =N/A 000.0 * Values from Table R402.1.2 (Oct 2023) Baseline UA Total 296.5 Proposed UA Total 287.6 Required Credits 8.0 Proposed Credits 8.0 from Tables 406.2 and 406. UA Percent Reduction 3% UA Reduction 8.9 If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406 are ≥ those required in Section R406, then the home meets the WSEC. ** Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Total Credits (406.2 & 406.3) 8.0 * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Air source ducted Heat Pump w/ Min HSPF2 of 10 (HSPF of 11). If htg design temp is 23F or below,a cold climate variable capacity heat pump is required. 1.0 Table R406.2 Energy Equalization Credits 3.0Variable Refrigerant Heat Pump or Air-to- Water Heat Pump Select Options Per Section R402.4.1.2 /1.5 ACH50 / For R-2, 0.20 cfm per ft2 at 50 Pa. / HRV with min SHR eff of 0.75 per IRC Section M1505.3 or IMC Section 403.8 Table R406.3 Energy Credits Option No. 2 Air Leakage Control and Efficient Ventilation Efficient Building Envelope 3.1 -3.10 Energy Credits (406.3)System No. 4 Option 2.2 Fuel Normalization Credits (406.2) 1 Option 3.6 5.0 Full Description For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI 550/590 High Efficiency HVAC Energy Credits 3.11 High Efficiency HVAC: Smart Thermostat 0.0 0.300 0.025 0.054 0.029 Proposed Design U-Factor Compliance Path / Total UA Alternative U Baseline New Construction R3 Single family dwellings and townhouses WSEC 2021 0.242 Brief Description of Selected Options* 1.5 Category Select System Type 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Renewable Electric Energy kWh Energy Credits *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements Ducts/distribution system in conditioned space per R403.3.2 Electric resistance, hydronic, ductless and gas fired systems < 80% AFUE systems not permitted 0.0 Electric heat pump water heater meeting NEEA Tier 3. 0.5 0.0 5.0 7 Appliance Package Efficient Water Heating: Drain Heat Recovery Efficient Water Heating Efficient Water Heating: Compact Hot Water Distribution 5.1 5.3-5.8 5.2 6 2.0 High Efficiency HVAC Distribution System Option 5.6 0.0 0.0 4 Option 4.1 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area, Proposed Design 2,190 sq. ft Classification Medium Dwelling Unit Exterior Doors Plan Component Door ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt 00.0 Fiberglass Door Custom 0.15 1 3 6 8 20 3.0 Refer to WSEC R402.1 Solid Core Door Custom 0.17 1 2 8 6 8 18 3.0 Refer to WSEC R402.1 Sliding Door Custom 0.29 1 8 8 64 18.6 Refer to WSEC R402.1 00.0 00.0 00.0 00.0 00.0 00.0 00.0 Sum of Area and UA 102 24.6 0 3 Exterior Doors Area Weighted U 0.242 Overhead Glazing Plan Component Glazing ID Description U Feet Inch Feet Inch - - - - - 0.0 0 0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 12 Plan Component Glazing ID Description U Feet Inch Feet Inch Exempt - - - 1 U=0.30 (Code Baseline)Table 406.2 0.30 1 1 6 69.0 2.70 2 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 6 36.0 10.80 3 U=0.30 (Code Baseline)Table 406.2 0.30 3 4 4 6 54.0 16.20 4 U=0.30 (Code Baseline)Table 406.2 0.30 3 6 4 6 81.0 24.30 5 U=0.30 (Code Baseline)Table 406.2 0.30 1 2 3 6.0 1.80 6 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 2 12.0 3.60 7 U=0.30 (Code Baseline)Table 406.2 0.30 1 5 4 20.0 6.00 8 U=0.30 (Code Baseline)Table 406.2 0.30 2 2 4 16.0 4.80 9 - - 10 - - 11 - - 12 - - Sum of Area and UA 234.0 70.2 0 Vertical Glazing Area Weighted U 0.300 Vertical Glazing and Doors Area Weighted U 0.282 Flat/Vaulted Ceilings Plan Component Attic ID Description U R60 blown Attic STD baffled 10-7 0.025 1,386 34.7 1,386 34.7 0 Walls (Above Grade) Width Ref. Ref. Height Notes Height Area Width Qt. Sum of Area and UA Qt. UAArea HeightWidth Sum of Area and UA Ref. UA Area UA 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Plan Component Wall ID Description Ref. U UA R21 cavity+R0 foam INT 2X6W Lap (Code Baseline)10-5 0.054 2,184 118 2,184 118 0 Net Area Sum of Area and UA 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref. U R30 vented Joist (Code Baseline)10-3 0.029 1,386 40 1,386 40 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab ID Description Ref. F FP 00 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab ID Description Depth Ref. U Area UA UA Sum of Area, Length and UA 0 0.0 0 0 0 Links to Download Forms, Checklists and Other Resources Compliance Certificate Instructions Insulation Certificate for Residential New Construction Duct Testing Affadavits Existing Construction New Construction Prescriptive Checklist for 2018 WSEC Alterations (Remodel) Worksheet EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter Show Ventilation Requirements Conditioned Floor Area 2,190 sq. ft. Number of Bedrooms 1 Run-Time Percent in Each 4-Hour Segment 100% Is the system Balanced?Verify system meets definition of 'Balanced Whole-House Ventilation' Is the system Distributed?Verify system meets definition of 'Distributed Whole-House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 40 CFM Show HVAC Thermal Distribution System Download RS-33 (2018) Is this a hydronic heating system? Location of Ducts Location of Air Handler Is Duct Testing Required? Yes Maximum Duct Leakage: Maximum total measured duct leakage per square foot 0.08 CFM25 per sq. ft. Maximum allowable total measured duct leakage 175 CFM25 A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7. Show Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: Nearest Weather Station Indoor Design Temperature 70 F Outdoor Design Temperature 17 F http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%2 Conditioned Space https://betterbuiltnw.com/resources/hvac-sizing-tool Link Prescriptive Checklist Affidavit, Existing Affidavit, New Worksheet No Sum of Perimeter and FP Slab Perim Compliance Certificate Insulation Certificate Sum of Area and UA Distributed Balanced Show Distribution System Calculator? Show Ventilation Calculator? Slab Slab Perim Lacey Conditioned Space Show Heating System Sizing? Area F 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Design Temperature Difference (∆T)53 F Conditioned Floor Area, Proposed Design 2,190 ft2 Conditioned Volume 17,520 ft3 0.00 Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Location of HVAC Distribution System Conditioned Space Sum of UA, including exempt door and window 288 Envelope Heat Load 15,241 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 10,028 Btu / Hour ((Volume X 0.6) X ∆T) X .018)) Building Design Heat Load 25,269 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 25,269 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 31,587 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 9.3 kW Building and Duct Heat Loss X 1.40 for all other systems Heat Pump 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Project Information Messages / Comments * Plan - 2190 B Elevation Review required for custom entries: - Doors City of Yelm UA Reduction = 8.96, Proposed UA is better than baseline by 3% Contact Information Soundbuilt Homes Window area is 10% of floor area PO Box 73790 - Puyallup, WA 98373 Whole House Mechanical Ventilation Airflow Rate: 40 CFM with Run Time Percent of 100%, Balanced, Distributed 253-848-0820 Maximum allowable total measured duct leakage: 176 CFM25 ANALYSIS SET UP What code compliance pathway are you using? Project Building Type? Occupancy Type? Code Version? WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/O Classification:Medium Dwelling Unit -- 2196 sq. ft. Baseline Description: Code Baseline - Baseline and proposed window areas are equal. About Your Selection:Up to 15 sf exempt window and 24 sf exempt door allowable RESULTS - Comparison of Baseline and Proposed Design ** Component Performance, R occupancies U *Area UA Area UA Doors U =0.300 102 30.5 102 24.6 Overhead Glazing U =0.500 0 0.0 0 0.0 Vertical Glazing U =0.300 225 67.5 225 67.5 Flat/Vaulted Ceilings U =0.024 1,392 33.4 1,392 34.8 Wall (above grade) U =0.056 2,200 123.2 2,200 118.8 Floors over Crawlspace U =0.029 1,392 40.4 1,392 40.4 Slab on Grade F =0.540 0 0.0 0 0.0 Below Grade Wall U =N/A 000.0 Below Grade Slab F =N/A 000.0 * Values from Table R402.1.2 (Oct 2023) Baseline UA Total 295.0 Proposed UA Total 286.1 Required Credits 8.0 Proposed Credits 8.0 from Tables 406.2 and 406. UA Percent Reduction 3% UA Reduction 9.0 If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406 are ≥ those required in Section R406, then the home meets the WSEC. ** Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Total Credits (406.2 & 406.3) 8.0 * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Air source ducted Heat Pump w/ Min HSPF2 of 10 (HSPF of 11). If htg design temp is 23F or below,a cold climate variable capacity heat pump is required. 1.0 Table R406.2 Energy Equalization Credits 3.0Variable Refrigerant Heat Pump or Air-to- Water Heat Pump Select Options Per Section R402.4.1.2 /1.5 ACH50 / For R-2, 0.20 cfm per ft2 at 50 Pa. / HRV with min SHR eff of 0.75 per IRC Section M1505.3 or IMC Section 403.8 Table R406.3 Energy Credits Option No. 2 Air Leakage Control and Efficient Ventilation Efficient Building Envelope 3.1 -3.10 Energy Credits (406.3)System No. 4 Option 2.2 Fuel Normalization Credits (406.2) 1 Option 3.6 5.0 Full Description For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI 550/590 High Efficiency HVAC Energy Credits 3.11 High Efficiency HVAC: Smart Thermostat 0.0 0.300 0.025 0.054 0.029 Proposed Design U-Factor Compliance Path / Total UA Alternative U Baseline New Construction R3 Single family dwellings and townhouses WSEC 2021 0.242 Brief Description of Selected Options* 1.5 Category Select System Type 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Renewable Electric Energy kWh Energy Credits *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements Ducts/distribution system in conditioned space per R403.3.2 Electric resistance, hydronic, ductless and gas fired systems < 80% AFUE systems not permitted 0.0 Electric heat pump water heater meeting NEEA Tier 3. 0.5 0.0 5.0 7 Appliance Package Efficient Water Heating: Drain Heat Recovery Efficient Water Heating Efficient Water Heating: Compact Hot Water Distribution 5.1 5.3-5.8 5.2 6 2.0 High Efficiency HVAC Distribution System Option 5.6 0.0 0.0 4 Option 4.1 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area, Proposed Design 2,196 sq. ft Classification Medium Dwelling Unit Exterior Doors Plan Component Door ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt 00.0 Fiberglass Door Custom 0.15 1 3 6 8 20 3.0 Refer to WSEC R402.1 Solid Core Door Custom 0.17 1 2 8 6 8 18 3.0 Refer to WSEC R402.1 Sliding Door Custom 0.29 1 8 8 64 18.6 Refer to WSEC R402.1 00.0 00.0 00.0 00.0 00.0 00.0 00.0 Sum of Area and UA 102 24.6 0 3 Exterior Doors Area Weighted U 0.242 Overhead Glazing Plan Component Glazing ID Description U Feet Inch Feet Inch - - - - - 0.0 0 0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 12 Plan Component Glazing ID Description U Feet Inch Feet Inch Exempt - - - 1 U=0.30 (Code Baseline)Table 406.2 0.30 1 1 6 69.0 2.70 2 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 6 36.0 10.80 3 U=0.30 (Code Baseline)Table 406.2 0.30 4 4 4 6 72.0 21.60 4 U=0.30 (Code Baseline)Table 406.2 0.30 2 6 4 6 54.0 16.20 5 U=0.30 (Code Baseline)Table 406.2 0.30 1 2 3 6.0 1.80 6 U=0.30 (Code Baseline)Table 406.2 0.30 1 6 2 12.0 3.60 7 U=0.30 (Code Baseline)Table 406.2 0.30 1 5 4 20.0 6.00 8 U=0.30 (Code Baseline)Table 406.2 0.30 2 2 4 16.0 4.80 9 - - 10 - - 11 - - 12 - - Sum of Area and UA 225.0 67.5 0 Vertical Glazing Area Weighted U 0.300 Vertical Glazing and Doors Area Weighted U 0.282 Flat/Vaulted Ceilings Plan Component Attic ID Description U R60 blown Attic STD baffled 10-7 0.025 1,392 34.8 1,392 34.8 0 Walls (Above Grade) Width Ref. Ref. Height Notes Height Area Width Qt. Sum of Area and UA Qt. UAArea HeightWidth Sum of Area and UA Ref. UA Area UA 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Plan Component Wall ID Description Ref. U UA R21 cavity+R0 foam INT 2X6W Lap (Code Baseline)10-5 0.054 2,200 119 2,200 119 0 Net Area Sum of Area and UA 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref. U R30 vented Joist (Code Baseline)10-3 0.029 1,392 40 1,392 40 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab ID Description Ref. F FP 00 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab ID Description Depth Ref. U Area UA UA Sum of Area, Length and UA 0 0.0 0 0 0 Links to Download Forms, Checklists and Other Resources Compliance Certificate Instructions Insulation Certificate for Residential New Construction Duct Testing Affadavits Existing Construction New Construction Prescriptive Checklist for 2018 WSEC Alterations (Remodel) Worksheet EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter Show Ventilation Requirements Conditioned Floor Area 2,196 sq. ft. Number of Bedrooms 1 Run-Time Percent in Each 4-Hour Segment 100% Is the system Balanced?Verify system meets definition of 'Balanced Whole-House Ventilation' Is the system Distributed?Verify system meets definition of 'Distributed Whole-House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 40 CFM Show HVAC Thermal Distribution System Download RS-33 (2018) Is this a hydronic heating system? Location of Ducts Location of Air Handler Is Duct Testing Required? Yes Maximum Duct Leakage: Maximum total measured duct leakage per square foot 0.08 CFM25 per sq. ft. Maximum allowable total measured duct leakage 176 CFM25 A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7. Show Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: Nearest Weather Station Indoor Design Temperature 70 F Outdoor Design Temperature 17 F http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%2 Conditioned Space https://betterbuiltnw.com/resources/hvac-sizing-tool Link Prescriptive Checklist Affidavit, Existing Affidavit, New Worksheet No Sum of Perimeter and FP Slab Perim Compliance Certificate Insulation Certificate Sum of Area and UA Distributed Balanced Show Distribution System Calculator? Show Ventilation Calculator? Slab Slab Perim Lacey Conditioned Space Show Heating System Sizing? Area F 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024 WSU Code Compliance Calculator, WSEC 2018 Design Temperature Difference (∆T)53 F Conditioned Floor Area, Proposed Design 2,196 ft2 Conditioned Volume 17,568 ft3 0.00 Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Location of HVAC Distribution System Conditioned Space Sum of UA, including exempt door and window 286 Envelope Heat Load 15,161 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 10,056 Btu / Hour ((Volume X 0.6) X ∆T) X .018)) Building Design Heat Load 25,217 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 25,217 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 31,521 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 9.2 kW Building and Duct Heat Loss X 1.40 for all other systems Heat Pump 1/25/2024I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325~Master.xlsm 3/26/2024