2025.0064.PV0005 Dorsey, Billy - PV Plans (4499)REV #2
BILLY DORSEY
15442 107TH LOOP SE
All corresponding changes are notated on the plans by revision clouds.
Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or
concerns.
Construction Engineering
Freedom Forever
Planset Revision Letter
Attn. City of Yelm (WA):
2/3/2025
Freedom Forever
engineering@freedomforever.com
The changes outlined in Revision Details have been applied to the plans corresponding to
the following customer:
Revision Details:
REV 1:
Updated code years to 2021 and 2023 NEC on cover page of planset. Sent to Engineering for stamps.
REV 2:
Swapped to deck mount attachments and updated attachment spacing to 24" on Roof 2, per Engineering.
THIS PROPOSED INSTALLATION COMPLIES WITH THE FOLLOWING:
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2023 NATIONAL ELECTRIC CODE
AS ADOPTED BY CITY OF YELM
CODES:
VICINITY MAP:
TABLE OF CONTENTS:
CONSTRUCTION NOTES:
ROOF MOUNT PHOTOVOLTAIC SYSTEM
PV-1 PROJECT DETAILS
PV-2 SITE PLAN
PV-2A ROOF PLAN WITH MODULES LAYOUT
PV-2B ARRAY DETAILS
PV-3 MOUNTING DETAILS
PV-3A MOUNTING DETAILS
PV-4 THREE LINE DIAGRAM
PV-5 CONDUCTOR CALCULATIONS
PV-5A ELECTRICAL CALCULATIONS
PV-6 EQUIPMENT & SERVICE LIST
PV-7 LABELS
PV-7A SITE PLACARD
PV-8 OPTIMIZER CHART
PV-9 SAFETY PLAN
PV-10 SAFETY PLAN
APPENDIX MANUFACTURER SPECIFICATION SHEETS
CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND
ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.
ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT
POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE
MOUNTED.
MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN
ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER
SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.
DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY
EXCAVATION TAKING PLACE
PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM
DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).
SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH
REQUIREMENTS OF ART. 690 OF THE 2020 NEC
THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER
UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM
SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS
INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT
ATTACHED TO THE ROOF USING CONDUIT MOUNT.
PV-1
FREE
D
O
M
F
O
R
E
V
E
R
I
N
D
Y
8.00
TE
M
P
L
A
T
E
CONTRACTOR LICENSE:
ELECTRICAL ADMINISTRATOR ALBRIG*807C1
FREEDOM FOREVER LLC
43445 BUSINESS PARK DR #110, TEMECULA,
CA 92590
Tel: (888) 557-6431
REVISED BY DATENO.
SHEET:
REVISIONS
JOB NO:
523558
DESIGNED BY:
K.N.
CLIENT:
BILLY DORSEY
15442 107TH LOOP SE, YELM, WA 98597
AHJ: CITY OF YELM
UTILITY: PUGET SOUND ENERGY
METER: X165248321
APN: 6231-00-01800
PHONE: (253) 820-1461
EMAIL: LEILANINICHOL@GMAIL.COM
SYSTEM:
SYSTEM SIZE (DC): 37 X 400 = 14.800 kW
SYSTEM SIZE (AC): 10.000 kW @ 240V
MODULES: 37 X FREEDOM FOREVER:
FF-MP-BBB-400
OPTIMIZERS: 37 X SOLAREDGE S440
INVERTER: SOLAREDGE SE10000H-USRGM
(PART/SKU: SE10000H-USRGM)
DATE:
2/3/2025
K.N.12/23/2024
2/3/20252
--
1
K.N.
-
GREG ALBRIGHT
SITE LOCATION
PROJECT DETAILS
THIS SYSTEM DESIGNED WITH:
WIND SPEED: 97
WIND EXPOSURE: B
SNOW LOAD: 15
1
EXP 08/30/2025
Jeff
Onorati
Digitally signed
by Jeff Onorati
Date: 2025.02.04
07:35:46 -08'00'