Loading...
2025.0064.PV0005 Dorsey, Billy - PV Plans (5688)REV #2 BILLY DORSEY 15442 107TH LOOP SE All corresponding changes are notated on the plans by revision clouds. Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or concerns. Construction Engineering Freedom Forever Planset Revision Letter Attn. City of Yelm (WA): 2/3/2025 Freedom Forever engineering@freedomforever.com The changes outlined in Revision Details have been applied to the plans corresponding to the following customer: Revision Details: REV 1: Updated code years to 2021 and 2023 NEC on cover page of planset. Sent to Engineering for stamps. REV 2: Swapped to deck mount attachments and updated attachment spacing to 24" on Roof 2, per Engineering. THIS PROPOSED INSTALLATION COMPLIES WITH THE FOLLOWING: 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2021 INTERNATIONAL EXISTING BUILDING CODE 2021 INTERNATIONAL FUEL GAS CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL PLUMBING CODE 2023 NATIONAL ELECTRIC CODE AS ADOPTED BY CITY OF YELM CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: ROOF MOUNT PHOTOVOLTAIC SYSTEM PV-1 PROJECT DETAILS PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B ARRAY DETAILS PV-3 MOUNTING DETAILS PV-3A MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-5A ELECTRICAL CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. PV-1 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (888) 557-6431 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 523558 DESIGNED BY: K.N. CLIENT: BILLY DORSEY 15442 107TH LOOP SE, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: X165248321 APN: 6231-00-01800 PHONE: (253) 820-1461 EMAIL: LEILANINICHOL@GMAIL.COM SYSTEM: SYSTEM SIZE (DC): 37 X 400 = 14.800 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 37 X FREEDOM FOREVER: FF-MP-BBB-400 OPTIMIZERS: 37 X SOLAREDGE S440 INVERTER: SOLAREDGE SE10000H-USRGM (PART/SKU: SE10000H-USRGM) DATE: 2/3/2025 K.N.12/23/2024 2/3/20252 -- 1 K.N. - GREG ALBRIGHT SITE LOCATION PROJECT DETAILS THIS SYSTEM DESIGNED WITH: WIND SPEED: 97 WIND EXPOSURE: B SNOW LOAD: 15 1 EXP 08/30/2025 Jeff Onorati Digitally signed by Jeff Onorati Date: 2025.02.04 07:35:46 -08'00'