101158552 YEL-23 REPL 1 POLE-signed (2)CØEIG691
CN
C
25T
8947
#
2
A
C
S
R
CN
C
9037
N
Vicinity Map
N.T.S.
Owner / Developer Contact Info
officeATTN:
PSE
-
-
KELLY ULICNY 425-429-0949
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
PHONE
CABLE TV
11813402 101158552
N/A 593250182
N/A 594153860
N/A N/A
N/A N/A
N/A 108144697
PROJECT PHASE
PWR
NOTIF# ORDER#
Superior
OH Misc Expense
UG Misc Expense
OH Xfmr Expense
UG Xfmr Expense
Removal
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
K. ULICNY 425-429-0949 4/4/23
S. REEVES 253-331-3897 4/4/23
...
J. WATT 509-714-3143 4/4/23
N/A YELM
YEL-23 REPL 1 POLE
DISTRIBUTION POLE REPLACEMENT
8947 CANAL RD SE, YELM, WA 98597
ASPLUNDH CONSTRUCTION
N/A N/A
N/A 101158552
AS NOTED 1 OF 1
THURSTON N/A N/A QSTHLE
SE18-T17N-R02E N/A N/A
1702E072 1702E068 1702E072 YEL-23
COMCAST
.
.
.
.
.
.
.
.
.
.
.
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:KELLY ULICNY
425-429-0949
KELLY.ULICNY@PSE.COM
...
...
...
10
1
1
5
8
5
5
2
YEL-23 REPL 1 POLE
DISTRIBUTION POLE REPLACEMENT
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
P01: 559881-147726 (Avg. Span = 321', Angle = 0°)
TREE TRIMMING REQ'D
-EX 40' CL 1, 1961 POLE TO BE REPLACED
-INST 45' CL 1 (PD451) 6010.1000
-DEEP SET +1' DUE TO CROSSWIND
-INST 1Ø PTP #2ACSR (TAN112) 6031.1010
-ROLL NEUT TO COMMON POSITION
-SLEEVE THROUGH WIRES
-TRANSFER 1Ø #2ACSR PRI & NEUT (NW/SE)
-RM EX 1Ø TERM & C/O
-RM EX RISER
-INST 2" RISER (RIS2CSS) 6042.1000
-INST 1Ø TERM & L/B C/O (TSU1C1) 6043.1000 (SW#Y645)
-FUSE @ 25T (3412400)
-TRANSFER 1Ø 1/0AL UG PRI (SW); EXTEND AS REQ'D
-ACTUAL 1Ø 1/0AL UG PRI ADDED L=_________ BATCH YEAR_________
-ACTUAL TRENCH L=_________
-RM EX DG & ANC
-CUT ANC 6" BELOW GRADE
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED
SITE PLAN
1" = 50'
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID # HEIGHT CLASS YEAR TOPPED RMVD
P01 559881-147726 40 1 1961
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P01 559881-147726 45 1
LEGEND
CONDUIT RISER
OVERHEAD TRANSFORMER
JUNCTION VAULT/JUNCTION BOX
NEW CONDUCTOR AND OR TRENCH LINE
DISCONNECT - FUSED
PULL VAULT OR SPLICE VAULT
EXISTING POLE
DOWN GUY
DISCONNECT - UNFUSED
NEW POLE
PADMOUNT TRANSFORMER
SECONDARY HANDHOLE
EXISTING CONDUCTOR TO BE REMOVED
OR ABANDONED
STREET LIGHT
TOTAL UNDERGROUND TRANSFORMER
ENERGY CUSTOMER DEMAND POINT
OR
OR
OR
OVERHEAD JUMPER CONNECTION
C
A
N
A
L
R
D
S
E
CANAL CT SE
T
H
E
A
R
O
S
E
D
R
S
E
SITE
Standoff Bracket
15" Min Length
Conduit Clamp
Conduit Field Face
Quadrant
Climbing
SpaceRoad Face
Quadrant
Climbing
Space
5" Min
CL
LC
Direction of Vehicular Traffic
CONDUIT RISER PLACEMENT DETAIL
TOP VIEW
NOT TO SCALE
General
- Return removed materials to the local storeroom or PSE storeroom.
OVERHEAD CONSTRUCTION
Poles & Structures
- Poles are to be installed or relocated as staked. Unless otherwise noted, all pole location measurements
are from the roadside face of the pole.
- All new poles set shall be the class indicated on the sketch, or better. Do not set a lower class pole than
specified.
- Install ground plate assembly on all new poles. Install Switch Ground Assembly per standard specification
6014.1000 at new gang operated switch locations.
- Install grid numbers on all new and existing poles as shown on sketch.
- Straighten existing poles as indicated or as necessary.
- Treat all field-drilled poles with copper napthenate wood preservative.
- Remove old poles after communication companies have transferred off and return to PSE storeroom. Fill
and crown pole holes and restore area similar to adjacent landscaping.
Conductors & Equipment
- Transfer all overhead and underground primary, secondary and service conductors and guys to new poles
set, unless otherwise indicated on this sketch.
- Transfer existing transformers to new poles unless otherwise indicated on this sketch.
- Use stirrups to connect all overhead and underground primary taps, and all transformers. Install at all sites
being worked within the scope of the project where they are currently missing.
- For 12kV construction, always install avian protection with 4/0 Cu covered jumpers and #4 SD
aluminum-covered tie-wire (MID 8454500), For 34 kV construction, use bare wire primary jumpers with
preformed helical grip ties.
- Apply avian protection devices when required per Standard 6015.2000.
- Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
- Connect primary taps and transformers to same phase as existing unless otherwise shown on the drawing.
- All neutral connections to be made with solid compression connectors. Connect all pole grounds to
common neutral.
- Use Load-interrupter cutouts (with arc shields) on all primary overhead and underground taps with fused
protection above 40T.
- Install Wildlife Protectors on all transformers.
UNDERGROUND CONSTRUCTION
Excavation
-Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of 36” of cover for
primary conductors and 24” of cover for secondary conductors.
-Road crossings and all trenches within the Right-of-way shall be of sufficient depth to provide a minimum
of 36” of cover for all conductors or as required by the permitting Agency.
-All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand cover.
-No rocks larger than 6” shall be included in backfill.
-Backfill in road crossings and within the Right-of-way shall be compacted to 95% density or as required
by the permitting Agency.
-Restore all excavated areas to original condition.
UTILITY POLE EROSION CONTROL DETAIL
TOP VIEW
FLOWING DITCH or BODY OF WATER
SLOPE
Secure bottom of fence
with gravel bags
Place straw mulch
on disturbed areaExcavated or
Augered Hole
Pole
SLOPE
Not to scale Adjacent to flowing ditches or bodies of water
Install silt fence around
pole excavation
J. WATT
4/10/23
2-81
2-572-45XX
2-54 x ______'
2-129