Loading...
yelm plaza material submittal packetSprinkler Model Max. Working Pressure psi (bar) Maximum Coverage Area Width x Length ft x ft (m x m) Flow Rate gpm (L/min) Pressure psi (bar) Sprinkler Identification Number (SIN) DH56 Dry EC 250 (17.2) 28 x 8 (8.5 x 2.4)23 (87.1)16.9 (1.2) RA1664 28 x 10 (8.5 x 3)28 (106)25 (1.7) Table A DH56 Dry EC HSW with standard escutcheon Features • Coverage for long and narrow light hazard spaces such as hallways, decks, and rooms • Coverage area up to 28 ft (8.5m) long and 10 ft (3m) deep • Available in four trim styles and a variety of finish combina- tions. Product Description The Reliable Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler is a quick-response sprinkler utilizing a sensitive 3mm glass bulb thermal element listed for use in light hazard applications. Dry sprinklers are intended for use on wet, dry, and preaction systems to protect indoor and outdoor areas that are subject to freezing. When used on wet systems, it is important that a minimum exposed length of barrel inside the face of the wall or insulation is provided to offset conduction of potentially freezing temperatures from the unconditioned (sprinkler) end along the barrel. See Figure 6 for guidelines on using dry sprinklers on wet systems. Environments where dry sprinklers are employed are often corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax prevents contaminants from entering the internal portion of the drop nipple and must not be removed. www.reliablesprinkler.com Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in accordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8.5m) wide and 10 feet (3m) deep. Model DH56 sprinklers are rated for 250 psi (17.2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. cULus Listed Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Bulletin 016 March 2022 Model DH56 EC HSW Coverage Area Figure 1 Model DH56 EC Horizontal Sidewall Sprinkler SIN RA1664 Technical Specifications Style: Extended Coverage Horizontal Sidewall Threads: 1” NPT or ISO7-1R1 Nominal K-Factor: 5.6 (80) Max. Working Pressure: 250 psi (17.2 bar) Max. Spacing: 28 ft (8.5m) Min. Spacing: 16 ft (4.9m) Material Specifications Inlet Fitting: Brass Alloy Flip Disk: Brass Alloy Seal: PTFE Coated Belleville Spring Outer Tube: Galvanized Steel Pipe Sprinkler Frame: Brass Alloy Bulb Insert: Copper Alloy Thermal Element: Glass Bulb Deflector: Bronze Alloy Load Screw: Brass Alloy Sprinkler Finishes See finish combination tables on following pages Sensitivity Quick Response Temperature Ratings 155°F (68°C) 175°F (79°C) 200°F (93°C) Recessed Escutcheons/Cover Plates Standard Escutcheon HB Escutcheon FP Escutcheon SWC Cover Plate Listings and Approvals cULus Listed for Light Hazard 28' [8.5m] Maximum Spacing 16' [4.9m] Minimum Spacing MODEL DH56 DRY SPRINKLER 4" [100mm] Min. from Ceiling 12" [300mm] Max. from Ceiling Wall Floor Coverage Area DH56DRYCOVAREA 28' [8.5m] 8' [2.4m] or 10' [3m] Based on Selected Discharge Flow and Pressure Shown here with standard escutcheon. See pages 3-6 for additional trim styles Bulletin 016 March 2022 Page 2 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with Standard Escutcheon Figure 2 System Tee 3" Dia. [76mm] Nominal Position of Escutcheon Wa l l Inlet Fitting 1" [25mm] Escutcheon Adjustment 1-15/16"" [53mm] Ceiling "A" Dimension 1/2" [12mm] Escutcheon Adjustment Sprinkler Can 2-1/8" Dia. [54mm] Hole in Wall016STD-A 4" [100mm] Min. 12" [300mm] Max. DH56 DRY HSW SPRINKLER, STANDARD ESCUTCHEON 1/2" [12mm] Nominal Protrusion 5/8" [16mm] 1/2" [12mm] "A" Dimension = 2" to 48" (50mm to 1200mm) Finish Combinations: Standard Escutcheon Sprinkler Escutcheon(2)(3) Bronze Polished Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)Polished Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel. “A” Dimension: 2” to 48” (50mm to 1200mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 3 of 10 www.reliablesprinkler.com “A” Dimension: 3-1/2” to 36” (90mm to 900mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 4 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with HB Escutcheon Figure 3 System Tee 3-1/2" [89 mm] Dia. Nominal Escutcheon Position 1/2" [13 mm] Escutcheon Adjustment "A" Dimension 2 1/2" Dia. [64 mm] Hole in Wall 1/2" [13 mm] Escutcheon Adjustment 1-15/16"" [49mm] 5/8" [16 mm] Sprinkler Can Inlet Fitting Escutcheon 1-1/4" [32mm] Nominal Projection 1-1/4" [32mm] Wa l l Ceiling 016HB Finish Combinations: HB Escutcheon Sprinkler Escutcheon(2)(3) Bronze Chrome Chrome Chrome White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. “A” Dimension: 3-1/2” to 48” (90mm to1200mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 5 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with FP Escutcheon Figure 4 Hole in Wall 3-1/4" [82mm] 2 5/8" Dia. [67mm] "A" Dimension System Tee Wa l l 4" [102mm] Min. 12" [305mm] Max. Ceiling Sprinkler Cup Escutcheon Inlet Fitting 1/4" [6mm] 1/4" [6mm] Escutcheon Adjustment Escutcheon Adjustment 1 1/4" [32mm] Nom Nominal Position of Escutcheon 5/8" [16mm] 016FP Finish Combinations: FP Recessed Escutcheon Sprinkler(1)Escutcheon(3)(4) Bronze Brass Chrome Chrome White Polyester(2)White Polyester Black Polyester(2)Black Polyester Custom Color Polyester(2)Custom Color Polyester Electroless Nickel PTFE(2)Stainless Steel Notes: 1. Cup for FP Recessed is unfinished galvanized steel except electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Note: Do not install the Model DH56 Dry Sprinkler with FP recessed escutcheon in locations where there is positive pressure in the cavity behind the sprinkler relative to the pressure at the sprinkler. “A” Dimension: 3-1/2” to 48” (90mm to1200mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 6 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with SWC Cover Plate Figure 5 4" [102mm] Min 12" [305mm] Max "A" Dimension 1/4" [6mm] Cover Plate Adjustment 1/4" [6mm] Cover Plate Adjustment Nominal Position of Cover Plate System Tee Inlet Fitting 5/8" [16mm] 1-9/16" [40mm] 2-5/8" [67mm] Dia. Hole in Wall 3-7/32" Dia. [82mm] Sprinkler Cup 016SWC Wa l l Ceiling Finish Combinations: SWC Concealed Cover Plate Sprinkler(1)Cover Plate(2) Bronze White Polyester Chrome Bright Chrome Dull Bright Brass Unfinished Bronze Custom Color Notes: 1. Cup for SWC Concealed is unfinished galvanized steel. 2. Cover plates do not carry corrosion resistant listings. Note: Do not install the Model DH56 Dry Sprinkler with SWC cover plate in locations where there is positive pressure in the cavity be- hind the sprinkler relative to the pressure at the sprinkler. Bulletin 016 March 2022 Page 7 of 10 www.reliablesprinkler.com Figure 6 Bulletin 016 March 2022 Page 8 of 10 www.reliablesprinkler.com Figure 7 Installation (General) Dry sprinklers connected to wet pipe systems must be installed as indicated in Figure 6 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. Reliable Model DH56 dry sidewall sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 7). DO NOT install Reliable Model DH56 dry sidewall sprinklers into elbows or couplings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. DH56 HSW with Standard Escutcheon Cut a 2-1/8” (54mm) diameter hole in the wall as shown in Fig. 2. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the escutcheon over the finished sleeve until tight to the finished surface. DH56 HSW with HB Escutcheon Cut a 2-1/2” (64mm) diameter hole in the wall as shown in Fig. 3. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the skirt over the finished sleeve until tight to the finished suface. DH56 HSW with FP Recessed Escutcheon Cut a 2-5/8” (67mm) diameter hole in the wall as shown in Fig. 4. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the FP escutcheon into the threaded cup. Final adjustment is made by turning the FP escutcheon clockwise until the flange makes full contact with the wall surface. DH56 HSW SWC Concealed Cover Plate Cut a 2-5/8” (67mm) diameter hole in the wall as shown in Fig. 5. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the SWC cover plate into the threaded cup. Final adjustment is made by turning the cover plate clockwise until the cover plate flange makes full contact with the finished surface. Note: 1. The Model XLO2 installation wrench for FP Recessed and SWC Concealed installations has a open side to accommodate the sprinkler deflector and can only be inserted in one way (see Figure 8). Care must be taken not to damage the deflector during installation. 2. Do not over-tighten sprinklers into fittings. It is recommended that Reliable dry sprinklers be installed using the wrench referenced in this bulletin. A pipe wrench may also be used to install dry sprinklers provided that it only engages the outer tube (steel pipe) of the assembly. Note that a pipe wrench will impart a large amount of torque into the final assembly. This torque will need to be matched or exceeded to remove the sprinkler at a later date. A leak free joint can normally be obtained by installing the sprinkler to a minimum torque of 22 ft-lb (30 N-m) after applying an appropriate thread sealant. 3. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. Reliable installation wrenches are designed to install sprinklers while bulb protectors are in place. REMOVE THE PROTECTORS AT THE TIME THE SPRINKLER SYSTEM IS PLACED INTO SERVICE. Removal of the protectors before this time may leave the glass bulb vulnerable to damage. Remove protectors by undoing the clasp by hand. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 4. Do not remove the wax fillet in the gap between the cup that supports the bulb and the wrenching boss. Step 3 Step 2 Step 1 Figure 8XLO2 Installation Procedure Bulletin 016 March 2022 Page 9 of 10 www.reliablesprinkler.com Maintenance Reliable Model DH56 series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents US Patent No. 7,841,418 Wrench Options F3R Wrench (Standard & HB trims)XLO2 Wrench (FP recessed and SWC trims) Ordering Information Specify: Sprinkler Type • Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Trim Style • Standard Escutcheon • HB Escutcheon • FP Recessed Esctucheon • SWC Cover Plate Temperature Rating • 155°F (68°C) • 175°F (79°C) • 200°F (93°C) Finish • See available combinations (depending on trim style) on pages 3-6 Length • “A” Dimension (face of fitting to finished wall surface, in 1/4” [6mm] increments) Installation Wrench • Model F3R (Standard & HB trims) • Model XLO2 (FP Recessed & SWC trims) Bulletin 016 March 2022 Page 10 of 10 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 3 0 8 MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) TECHNICAL DATA Page 1 of 4 Form No. F_033014 Rev 03 December 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK350 is a small, thermosensitive, glass-bulb spray sprinkler that is available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special polyes- ter and electroless nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for instal- lation in corrosive environments and are Listed/Approved, as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414017, G414018, G4980020, and G4060054 LPCB Approved: Certificate 096e/03 CE: Standard EN 12259-1,DOP Sprinklers_VdS_23-5-13, DOP Sprinklers_LPCB_5-2-19 & DOP_VK350ENT_6-11-19 China Approval: Approved according to China GB standard MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832- MED-1003 UKCA Approved: Standard EN 12259-1; Certificate Number 0832-UKCA-CPR-S5029; UKCA DOC_S5029; 2021. NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATASpecifications: Minimum Operating Pressure: 7 PSI (0.5 bar)* Maximum Working Pressure: 175 PSI (12 bar) wwp. Factory tested hydrostatically to 500 PSI (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2” NPT, 15 mm BSPT, 3/4” NPT, or 20 mm BSPT Nominal K-Factor: 8.0 U.S. (115.2 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-5/16” (59 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 PSI (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 PSI (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or phosphor bronze UNS-C51000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel alloy, coated on both sides with PTFE tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and stainless steel UNS-S30400 For Polyester Coated Sprinklers: Belleville spring-exposed For ENT Coated Sprinklers: Belleville spring-exposed, screw and pipcap - ENT-plated. Replaces Form F_033014 Rev 01 Dated August 2023 (Added UKCA approval throughout and erased obs. part #’s 14817 and 06764.) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) TECHNICAL DATA Page 2 of 4 Form No. F_033014 Rev 03 December 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK350 by first adding the appropriate suffix for the sprinkler finish, then by adding the appropriate temperature rating suffix to the sprinkler base part number. Finish Suffix: Brass = A, chrome = F, white polyester = M-/W, black polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK350 with a 1/2” thread, brass finish and a 155 °F/68 °C temperature rating = Part No. 18259AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets:A. Six-head capacity: Part No. 01724A (available since 1971)B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK350 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Sprinkler Wrench Figure 2: Sprinkler Dimensions 2-5/16ʺ (59 mm)Nominal Pipe Engagement 7/16ʺ (11 mm) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) TECHNICAL DATA Page 3 of 4 Form No. F_033014 Rev 03 December 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, chrome, white polyester, black polyester, and ENT Corrosion-Resistant Coatings3: White polyester, black polyester and ENT. ENT are available in all temperature ratings, except 135 °F (57 °C). Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) TECHNICAL DATA Page 4 of 4 Form No. F_033014 Rev 03 December 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: The Microfast® Quick Response Upright Sprinkler VK350 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 1 (UL) Microfast® Quick Response Upright Sprinkler VK350 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria.) NPT BSPT U.S.metric2 Inches mm cULus4 VdS LPCB CE MED10 UKCA CCCF 18257 VK350 3/4”--8.0 115.2 2-5/16 59 A1, B2 A1 A1 B2, B47 B1 A1 -- 18278 VK350 --20 mm 8.0 115.2 2-5/16 59 A1, B2 A1 A1 B2, B47 B1 A1 -- 182599 VK350 1/2”15 mm 8.0 115.2 2-5/16 59 A1, B2 A1 --B2, B47 ------ 2023711 VK350 --20 mm 8.0 115.2 2-5/16 59 C3 ----------C3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06665B VK350 3/4”--8.0 115.2 2-5/16 59 A1, B2 A1 A1 B17 B1 ---- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) C - 155 °F (68 °C), 200 °F (93 °C), and 286 °F (141 °C) Approved Finishes 1 - Brass, chrome, white polyester5,6, and black polyester5,6 2 - ENT5 3 - Chrome 4 - Brass, chrome, white polyester5,6, and black polyester5,6, and ENT Footnotes 1. Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2. Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5. cULus Listed as corrosion-resistant. 6. Other colors are available on request with the same Listings and Approvals as the standard colors. 7. CE: Standard EN 12259-1, Declaration of Performance DOP Sprinklers_LPCB_5-2-19 & DOP_VK350ENT_6-11-19. 8. CE: Standard EN 12259-1, Declaration of Performance DOP Sprinklers_VdS_23-5-13. 9. The 1/2” NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. 10. MED Certified, Standard EN 12259-1, EC-certificate 0832-MED-1003. 11. Approved according to China GB Standard. MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) TECHNICAL DATA Page 5 of 4 Form No. F_033014 Rev 03 December 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK350 is FM Approved as a quick response Non-Storage upright sprinkler, as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Microfast® Quick Response Upright Sprinkler VK350 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria below.) NPT BSPT U.S.metric2 Inches mm 18257 VK350 3/4”--8.0 115.2 2-5/16 59 A1, B2 18278 VK350 --20 mm 8.0 115.2 2-5/16 59 A1, B2 182595 VK350 1/2”--8.0 115.2 2-5/16 59 A1, B2 202377 VK350 --20 mm 8.0 115.2 2-5/16 59 C3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06665B VK350 3/4”--8.0 115.2 2-5/16 59 A1, B2 Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) C - 155 °F (68 °C), 200 °F (93 °C), and 286 °F (141 °C) Approved Finishes 1 - Brass, chrome, white polyester4, and black polyester4 2 - ENT6 3 - Chrome Footnotes 1. Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2. Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4. Other colors are available on request with the same Approvals as the standard colors. 5. The 1/2” NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. 6. FM approved as corrosion-resistant. 7. Approved according to China GB Standard. Replaces Form F_033014 Rev 01 Dated August 2023 (Added UKCA approval throughout and erased obs. part #’s 14817 and 06764.) BULLETIN The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com CARE AND HANDLING OF SPRINKLERS Page 1 of 4 Form No. F_091699 18.10.11 Rev 16.1.P65 SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: • Store sprinklers in a cool, dry place. • Protect sprinklers during storage, transport, handling, and after installation. • Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, or buckets. • Keep sprinklers separated at all times. DO NOT allow metal parts to contact sprinkler operating elements. For Pre-Assembled Drops: • Protect sprinklers during handling and after installation. • For recessed assemblies, use the protective sprinkler cap (Viking Part Number 10364). Sprinklers with Protective Shields or Caps: • DO NOT remove shields or caps until after sprinkler installation and there no longer is potential for mechanical damage to the sprinkler operating elements. • Sprinkler shields or caps MUST be removed BEFORE placing the system in service! • Remove the sprinkler shield by carefully pulling it apart where it is snapped together. • Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: • DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler into a fitting. • Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. • DO NOT install sprinklers onto piping at the floor level. • Install sprinklers after the piping is in place to prevent mechanical damage. • DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or indirect impacts. • DO NOT attempt to remove drywall, paint, etc., from sprinklers. • Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2” NPT: 14 ft-lbs. (19.0 N-m) 3/4” NPT: 20 ft-lbs. (27.1 N-m) 1” NPT: 30 ft-lbs. (40.7 N-m) WARNING Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com. CORRECT (Original container used) INCORRECT (Placed loose in box) CORRECT (Protected with caps) INCORRECT (Protective caps not used) CORRECT (Piping is in place at the ceiling) INCORRECT (Sprinkler at floor level) CORRECT (Special installation wrenches) INCORRECT (Designated wrench not used) Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) BULLETIN The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com CARE AND HANDLING OF SPRINKLERS Page 2 of 4 Form No. F_091699 18.10.11 Rev 16.1.P65 PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handling and Storage: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap- on shields and caps are factory installed and are intended to help protect the operating elements from mechanical damage during shipping, storage, and installation. NOTE: It is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets* when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: • The sprinkler has been installed*. • The wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Figure 1: Sprinkler shield being removed from a pendent sprinkler.Figure 2: Sprinkler cap being removed from a pendent sprinkler.Figure 3: Sprinkler cap being re-moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. • To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. • To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. Refer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. BULLETIN The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com CARE AND HANDLING OF SPRINKLERS Page 3 of 4 Form No. F_091699 18.10.11 Rev 16.1.P65 GENERAL HANDLING AND STORAGE INSTRUCTIONS: • Do not store in temperatures exceeding 100 °F (38 °C). Avoid direct sunlight and confined areas subject to heat. • Protect sprinklers and cover assemblies during storage, transport, handling, and after installation. -- Use original shipping containers. -- Do not place sprinklers or cover assemblies loose in boxes, bins, or buckets. • Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work is being completed. • Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers. NOTE: The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. • Do not over-tighten the sprinklers into fittings during installation. • Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. • Do not attempt to remove drywall, paint, etc., from the sprinklers. • Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Concealed Sprinkler and Adapter Assembly with Protective Cap CAUTION: CONCEALED COVER ASSEMBLIES ARE FRAGILE! TO ASSURE SATISFACTORY PERFORMANCE OF THE PRODUCT, HANDLE WITH CARE. Cover Plate Assembly (Pendent Cover 12381 shown) Concealed Sprinkler and Adapter Assembly (Protective Cap Removed) BULLETIN The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com CARE AND HANDLING OF SPRINKLERS Page 4 of 4 Form No. F_091699 18.10.11 Rev 16.1.P65 USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX-COATED SPRINKLERS Many of Viking’s sprinklers are available with factory-applied wax coating for corrosion resistance. These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax-Coated Sprinklers: • Store the sprinklers in a cool, dry place (in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table 1 below.) • Store containers of wax-coated sprinklers separate from other sprinklers. • Protect the sprinklers during storage, transport, handling, and after installation. • Use original shipping containers. • Do not place sprinklers in loose boxes, bins, or buckets. Installation of Wax-Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax-coated Viking sprinklers (any other wrench may damage the unit). • Take care not to crack the wax coating on the units. • For touching up the wax coating after installation, wax is available from Viking in bar form. Refer to Table 1 below. The coating MUST be repaired after sprinkler installation to protect the corrosion-resistant properties of the sprinkler. • Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. • Inspect the coated sprinklers frequently soon after installation to verify the integrity of the corrosion resistant coating. Thereafter, inspect representative samples of the coated sprinklers in accordance with NFPA 25. Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. TABLE 1 Sprinkler Temperature Rating (Fusing Point) Wax Part Number Wax Melting Point Maximum Ambient Ceiling Temperature1 Wax Color 155 °F (68 °C) / 165 °F (74 °C)02568A 148 °F (64 °C)100 °F (38 °C)Light Brown 175 °F (79 °C)04146A 161 °F (71 °C)150 °F (65 °C)Brown 200 °F (93 °C)04146A 161 °F (71 °C)150 °F (65 °C)Brown 220 °F (104 °C)02569A 170 °F (76 °C)150 °F (65 °C)Dark Brown 286 °F (141 °C)02569A 170 °F (76 °C)150 °F (65 °C)Dark Brown 1 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) REGULATORY AND HEALTH WARNINGSBULLETIN The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 1 Form No. F_111218 18.11.15 Rev 18.1 New Bulletin 1. DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions. WARNING STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to, lead, nickel, butadiene, titaninum dioxide, chromium, carbon black, and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov 2. WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking’s current list price schedule at www.vikinggroupinc.com or contact Viking directly. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Glass Bulb Sprinklers Bu l l e t i n 0 1 4 D e c e m b e r 2 0 2 1 Bulletin 014 December 2021 Model F1FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1FR56LL & F1FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Con- tent Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprinkler. 1. Underwriters Laboratories Inc. and Certified for Cana- da (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhütung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Lab- oratories of Canada Certified for Health Effects to NSF/ ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) 7. WaterMark certified. Certificate Number 23347. (WM) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall Recessed Pendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprinklers with a glass bulb thermal element. Model F1FR series sprinklers are Standard Spray sprinklers, with the exception of the Model F1FR56 Conventional sprinkler which is an Old-style/Conventional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same tem- perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s 2. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. Model F1FR Series sprinklers provide a wide range of options where quick-response, glass bulb sprinklers are used:• Pendent, recessed pendent, upright, horizontal side - wall, and vertical sidewall deflectors• K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric)• Flush, recessed, and concealed installations See the Design and Installation Information table in this Bul- letin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizontal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Recessed Es - cutcheon Data table in this Bulletin for listing and approval infor- mation with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cover plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and Installation Infor- mation and Listed and Approved Temperature Ratings tables in this Bulletin for further information on approved cover plate options. Application Model F1FR Series sprinklers are intended for use in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Having Juris- diction. Care must be exercised that the k-factor, tempera- ture rating, deflector style, and sprinkler type are in accor- dance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprin- klers must be used in accordance with their listings and ap- provals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or protec- tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Re - move the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protec- tor before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1FR Series sprinklers must be installed with the Reli- able sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the specific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutcheon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a facto- ry-installed Model CCP cup. A protective cap is installed at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread- off cover plate assembly. The cover plate and sprinkler cup as - semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model W4 wrench is used to engage the sprinkler wrenching sur- faces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent dam- age to the sprinkler. Do not wrench any other part of the sprinkler/ cup assembly. Installation is completed by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/ cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not spe - cifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s 3. Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 W4 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC, WM 1,2,3,4 Recessed Pendent 2.25 57 W4 RA1414 cULus, FM, LPCB, VdS, EC, WM 1,2,3,4 Concealed Pendent 2.25 57 W4 RA1414 cULus,VdS,EC, WM 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC, WM 1,2,3,4 "Conventional (Pendent or Upright)"2.25 57 W2 RA1475 LPCB, VdS, EC, WM 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 W4 RA1415 cULus, ULH Concealed Pendent 2.25 57 W4 RA1415 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 W4 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pen- dent or Upright)2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (5) VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s 4. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb F1FR28 Pendent cULus Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS F1FR42 Pendent cULus Recessed Pendent cULus Upright cULus F1FR42LL Pendent cULus, ULH Recessed Pendent cULus, ULH F1FRXLH Pendent cULus Recessed Pendent cULus Upright cULus F1FR56 Pendent cULus, FM, LPCB, VdS, EC, WM Recessed Pendent cULus, FM, LPCB, VdS, EC, WM Concealed Pendent*cULus, WM cULus,VdS,EC, WM cULus, WM Upright cULus, FM, LPCB, VdS, EC, WM “Conventional (Pendent or Upright)”LPCB, VdS, EC, WM F1FR56LL Pendent cULus, ULH Recessed Pendent cULus, ULH Concealed Pendent*cULus, ULH F1FR56 Horizontal Sidewall cULus, FM Recessed Horizontal Sidewall cULus, FM F1FR56 Vertical Sidewall (Pen- dent or Upright)cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model F1 (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC, WM cULus, FM, LPCB, VdS, EC, WM cULus, VdS, EC, WM RA1414 F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s 5. Fig. 1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s 6. Fig. 3 Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon Fig. 4 Model F1FR56/F1FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s 7. Fig. 5 - Model F1FR56/F1FR56LL Concealed Pendent sprinkler with low profile 5/16- inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model F1FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Finishes (1) (2) Standard Finishes Sprinkler Escutcheon Cover plate Bronze Brass Chrome Chrome Chrome White White Polyester (3)(6)(7)White Special Application Finishes Sprinkler Escutcheon Cover plate Electroless Nickel PTFE(3)(4) Electroless Nickel PTFE Bright Brass Black Polyester (3)(6)(7)Bright Brass Black Bright Brass (5)Black Off White Off White(6)(7) Off White Satin Chrome Satin Chrome Satin Chrome (1) Other finishes and colors may be available on special order. Consult the factory for details. (2) Paint or any other coating applied over the factory finish will void all approvals and warranties. (3) cULus Listed as Corrosion Resistant. (4) FM Approved as Corrosion Resistant for SIN RA1414, RA1425, RA1435, and RA1485. (5) 200*F (93*C) maximum temperature rated sprinkler only. (6) VdS Approved for RA1425, RA1414, RA1418, and RA1475. (7) LPCB Approved for RA1425, RA1414, and RA1475. Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector:CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup:CDA Alloy 651 or 693 Washer:Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb:Glass Ordering Information Specify: 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42] [F1FR42LL][F1FRXLH][F1FR56][F1FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 12/21 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many pre - cision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Ja n 20 2 2 NO T E : Pl e a s e se e we b s i t e fo r up d a t e d ve r s i o n s of K2 . 8 , K4 . 0 , K4 . 2 , an d XL H Sp r i n k l e r s c (RULus LISTED KENNEDY VALVE UL/FM BUTTERFLY VALVES FM APPROVED Designed for the Fire Protection Industry Sizes: 2-112", 3",4",6", S" 300 PSI Rated Double Seal Design for Bubble Tight Shut Off Outdoor Rated CA, State Fire Marshall Accepted Lightweight Fusion Bonded Coated Body Low Torque Operation Easy to Read Flag Type Indicator Kennedy Valve-UUFM Butterfly Valves 11-1 I KENNEDY VALVE Division of NicWane, Inc. 1021 East Water St., Elmira,NY 14901 (607) 734-2211 j t Grooved End Butterfly Valves 21/2" to 8" Figure G300/G30OC & 01 G 300 psi with Supervisory Tamper Switch 4.6 �{ 04 9 2.5 Note: "E will be MINIMUM allowed pipe I.D. Exercise care handling and installing Kennedy Valve-UUFM Butterfly Valves 11-2 Sizes 2 1/2"- 6" t G300/G300C Outdoor Rated UL/FM Available Normally Open and Normally Closed i { s t Size 8" Only OIG Outdoor Rated UL Available Normally Open ' and Normally Closed j V KENNEDY VALVE FM c �, � S Division of McWane, Inc. O Uffm 1021 East Water St., Elmira,NY 14901 (607) 734-2211 Grooved End Butterfly Valves 2 1/2" to 8" Figure G300E/G300EC & 02G 300 psi with Supervisory Tamper Switch • Extended Length Valves Equipped with Four 3/4" NPT Ports • 4"-8" Sizes Approved for Cross Connection • NSF61 Certified Connection Control and Hydraulic Research at the University of 4.6 Southern California Sizes 2 1/2 " - 6" 4//r G300E / G300EC Outdoor Rated UL/FM Available Normally Open 02 S3/4-14NPT and Normally Closed f21 EA SIDE 'Port' .A. 0 .,A" 4NPT 8" Only 02G Outdoor Rated UL Available Normally Open and Normally Closed Note:Disc does not protrude past the "B" dimension of the body on any size in the open position. Exercise care handling and during installation Kennedy Valve-UL/FM Butterfly Valves 11-3 t c KENNEDY VALVE FM ; us Division of McWane, Inc. 1021 East Water St., Elmira,NY 14901 (6O7) 734-2211 Wafer Butterfly Valves 2112" to 8" 4.6 Figure W30OM3O0C,W3001, & 01W 300 psi with Supervisory Tamper Switch t l 9.3 1. fl act 0& M - M ifaWIPAMW�E r.�E:� INRTiil• - &Mtir�ClClE:�E:�E:� f+i 1Tt:I+Y�I f.T�il ��.-i'E:��•yL:��•yE=lEtyLlK1L! IMt{T'III MIN I 111111111111EM 61111111111111OVUM C1�� M F• Sizes 2 1/2"- 6" W3001W300C/W3001 ! Outdoor Rated UL /FM Available Normally Open and Normally Closed i 8" Size Only j 02G Outdoor Rated UL Available Normally Open and Normally Closed ! f ,2[0�k,MMSM 0 �s►� :I•l.Ydr4K* _r l i il, leg :l :z•Y:C -.,. ®MMM ! Ica C![! lMl WA72 WX"I tip i►A*.a WIX'! WX*,M jE' 1(11 E:*.M �•�■t*c11«:2M-Wa9:11aacPC] 0 OVA IE WM 90CE &M-2 WAC11 OWN: AI,r1XQaMEIaIW-1IK*:IirIK.i ■►.T��,���rf�.yi����K0:1WIMW,!! • i �Dimenions B D, and E are referenced in Installation Instructions E Is MINIMUM allowed Pipe I.D. Exercise care handling and during Installation Kennedy Valve-UUFM Butterfly Valves 11-4 KENNEDY VALVE Division of Mc Wane, Inc. 1021 East Water St. Elmira, NY 14901 UL/FM BUTTERFLY VALVES FM g COUS APPROVED LISTED INSTALLATIONS INSTRUCTIONS FOR INDOOR & OUTDOOR USE CAUTION PRIOR TO INSTALLATON OF SUPERVISORY SWITCHS IN FIRE PROTECTION SYSTEMS, REFER TO THE FOLLOWING STANDARDS: 1) NFPA 13: STANDARDS FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2) NFPA 25: INSPECTION, TESTING, MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS 3) NFPA 70: NATIONAL ELECTRICAL CODE 4) NFPA 72 NATIONAL FIRE ALARM CODE WARNING 1) REMOVE CORD GRIP FROM GEARBOX BEFORE INSTALLING CONDUIT 2) METALLIC CONDUIT REQUIRED BY NEC FOR PROPER GROUNDING 3) CONDUIT JOINTED MUST BE SEALED WITH CONDUIT SEALANT 4) INSTALL SWITCH IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND/OR LOCAL ORDINANCES 5) ASSURE ALL DEVISES ARE PROPERY GROUNDED G3 0C, G300EC, 02G 02GC FOR INDOOR & OUTDOOR USE FM Q W300,W300C, 01 W, 01 WC CL US i �— 4.6 —+-� 2.5 5.5 11O.A.M." ;'A" xr G300 b SHOWN PHIS STYLE AVAILABLE ON 2.5', 3", 4", 6' & 8" SIZES NOTE: INTEGRAL GEARBOX STYLE APPROVED 2015 FIRE PROTECTION PRODUCT IS NOT NSF CERTIFIED. FOR ACQUIRING NSF61 CERTIFICATION OR USC LISTINGS, CONTACT THE KENNEDY VALVE SALES 01 G DEPART. 8" SHOWN GROOVED END CONNECTIONS: FOR USE WITH STEEL GROOVED END PIPE (IPS) MATING PIPE AND COUPLINGS TO CONFORM TO IPS STEEL PIPE DIMENSIONS FOR OUTSIDE GROOVE AND GASKET SEATING DIMENSIONS. SEE DIAGRAM DIM "E" FOR MINIMUM INSIDE DIAMETER OF PIPE. PIPE CONNECTION SPECIFICATIONS -ALL VALVES RATED 300 PSI SUPERCEDES IISSUED DRAWING DATE PAGE KENN F M VALVE BY DATE 32271-04 DIVISION OF MCWANE. INC. V TECHNICAL SERVICE MANUAL N/A N/A PJD 2/16/21 (PAGE 1/2) BUTTERFLY VALVES Models: G300/G300E/G30OC/G300EC/W300/W3OOE/W30OC/W 300EC/W30001/O1G/02G/OI W SUPPLEMENTARY INSTALLATION INSTRUCTIONS Information shown here is intended to supplement, not to replace, instructions that are shipped with each valve. Dimensional information regarding minimum pipe I.D. and disc protrusion are shown on dimensional page for particular valve. Exercise care handling and during assembly. Grooved Body For use with IPS grooved end. see valve dimensional information for min. pipe I.D. (dimension E) Valves shall be installed by person(s) certified to install grooved end fittings in a fire protection system by authority having jurisdiction: "Follow grooved coupling manufacturers latest published directions. Wafer Body For installation between two ANSI B16.1, 1251b. flanges see valve dimensional information for min. pipe I.D. (dimension E) 1. Two flanged mating pieces should be placed at a distance apart that is slightly more than the thickness of the body (dimension B on wafer table) 2. A minimum of 2 studs shall be placed through adjacent flange holes so that the lower trunnion of the valve can fit between them. Normally this is the bottom 2 holes if the valves will be vertical with open/ closed indicator on top 3. Place the valve between the flanges taking care to not disturb the body gaskets. 4. Place remaining studs around the valve and tighten using an alternating pattern until desired torque is reached. 5. O-ring gaskets are shipped with valve to help facilitate installation against ANSI class flanges. When mating to grooved flange adapters the o-ring gaskets can be discarded. Switch Wiring 1. Valve has internal switches that operate from the OPEN position. Normally Closed valves are an option(W30OC/G30OC/G300EC), and operate from CLOSED position 2. One switch has dual leads that is for connection to the SUPERVISORY circuit of an alarm panel. The other switch has single leads and is intended to be connected to AUXILIARY equipment 3. Tuck unused leads into junction box (not provided) 4. Always comply with national codes, local codes and NFPA 13/71 and 72 G300,G300E,W300E WIRING 21/2"- S" VALVE NORMALLY OPEN (G300,G300E,W300,01G,02G,01W) OR VALVE NORMALLY CLOSED(G300C,W300C,G300EC,O1GG02GC,OIWC Supervisory Switch Auxiliary Switch Blue Brown Case Blue/ Brown/ End of Line Ground Orange4-Yellow/ Orange From Listed Device or Alarm Panel' Next ValveYellow en Rated: 120 VAC, 28 VDC, .25 A Orange Wiring Notes: Connection to power limited circuitry is required. Auxiliary switch connections are not intended for electrical supervision. Switches are checked at factory, check continuity with valve fully open (or closed for normally closed volves),switches activates within 2 turns of handwheel from open. Kennedy Valve-UL/FM Butterfly Valves 11-5 Y.1 A% KENNEDY YAK �� 4a y,( A Cornerstone of the Cotni T Since 1907 ISO 9001 Certified ISO 14001 Certified fly gas 1819 Clarkson Road, Chesterfield, MO 63017 US: 800.325.4467 | Canada: 800.882.4666 | sales@BullMooseIndustries.com EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET Nominal Pipe Size (inches)1-1/4”1-1/2”2”2-1/2”3”4” O.D. (in)1.660 1.900 2.375 2.875 3.500 4.500 I.D. (in)1.530 1.728 2.203 2.705 3.334 4.310 Empty Weight (lb/ft)1.222 1.844 2.330 2.809 3.361 4.968 Water Filled Weight (lb/ft)2.019 2.860 3.982 5.299 7.144 11.290 C.R.R.*1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY APPROVALS AND SPECIFICATIONS • ASTM A135, Grade A • ASTM A795, Type E, Grade A • Pressure rated to 300 psi • Underwriters Laboratories— United States of America • Underwriters Laboratories—Canada • Factory Mutual • NFPA-13 • NFPA-13R • NFPA-14 • CIVIL DEFENSE APPROVAL— United Arab Emirates • Made in the United States of America • UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, preaction and deluge sprinkler systems. • LEED v4 Certified FINISHES AND COATINGS • Eddy Flow Sprinkler Pipe receives an OD mill coating of water-based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. • Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy Guard II MIC preventative coating. EG2 has been tested at independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION • Every length of Bull Moose fire sprinkler pipe features large, easy-to- read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Locations Comments System TypeDate Eddy Flow - Black Eddy Flow - Hot Dip Galvanized PRINTED IN USA PAGE 1 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 UL, CUL and CSFM Listed, FM Approved, LPCB Approved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Ordering Information Nominal Pipe Size Model Part Number 2"DN50 VSR-2 1144402 2 1/2"DN65 VSR-2 1/2 1144425 3"DN80 VSR-3 1144403 3 1/2"-VSR-3 1/2 1144435 4"DN100 VSR-4 1144404 5"-VSR-5 1144405 6"DN150 VSR-6 1144406 8"DN200 VSR-8 1144408 Specifications subject to change without notice. Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 2 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. ADAPTER USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DN50 ONLY ADAPTER 50mm 20mm ±2mm MAX. DWG# 1146-1F Fig. 1 NOTE: For copper or plastic pipe use Model VSR-CF. Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms (Flowing water activates device in one direction only.) DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOWDIRECTION OF WATERFLOW Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts TorqueLightwallSchedule 10 (UL)Schedule 40 (UL)BS-1387 (LPC)DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .125/- .062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 -2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 ---- VSR-2 1/2 -DN65 3.000 76.1 ------0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ± .125 50.8 ± 2.0 VSR-3 1/2 3.5 -4.000 101.6 --0.120 3.05 0.226 5.74 ---- VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 -5.563 141.3 --0.134 3.40 0.258 6.55 ---- VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 --0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. PRINTED IN USA PAGE 3 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. DWG 1146-4 Fig. 2 Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Terminal Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector’s test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions DWG. 1146-14 3.50 in (89.0 mm) 2.34 in (59.4 mm) PIPE DIA. + 5.25 in (+ 133.4 mm) 5.56 in (141.2 mm)2.00 in (50.8 mm) U-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 – DN 65 2–2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 – DN 200 3–8 in DWG 1146-15 GREEN GROUND SCREWS Fig. 7 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see “Switch Terminal Connections” drawing and warning note (Fig. 4). Fig. 5 Typical Electrical Connections LO AD TO B E L L NEUTRAL FROM BELL CONNECTOR EOL (End Of Line Resistor) BELLNEUTRAL FROM BREAKER BREAKER LINE FROM BREAKER NOTE: When connecting to a UL Listed control panel, use the panel’s resistor value for circuit supervision. PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 4 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Removal of Waterflow Switch • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. Fig. 8 Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. DWG# 1146-10 BREAK OUT THIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. DO NOT REMOVE (2) RETARD HOUSING SCREWS REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE RETARD/SWITCH ASSEMBLY (2) ORIGINAL MOUNTING SCREWS (2) LOCATING PINS (2) LOCATING PIN BOSSES IN BASE BASE OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 55 www.tolco.com Revision 10/24/2007 Size Range — 3/8" rod, pipe sizes 1/2" thru 4" Material — Carbon Steel Function — Practical and economical bracket used to support piping from wood, concrete or steel beams. Features — Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13: 1/2" thru 2" pipe requires 3/8" fastener, 21⁄2" thru 4" pipe requires 1/2" fastener.* Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe. *Note — Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number and finish Fig. 58 - Threaded Side Beam Bracket UL Listed Fastener Table Pipe Size Qty. Fastener Type Material 2 2 #16 x 2 Drive Screws Wood 2 1 3/8 Lag Bolt Wood 21⁄2 - 4 1 1/2 Lag Bolt Wood 31⁄2 2 1/4 x 11⁄2 Lag Bolt Wood 4 2 1/4 x 2 Lag Bolts* Wood 4 2 1/4 x 1 tek screws 14 gauge 4 2 1/4 x 1 tek screws 16 gauge * No pre-drilling required Dimensions • Weights Pipe Rod Max. Rec. Approx. Size Size A B C Load Lbs.* Wt./100 1/2 thru 4 3/8 23⁄4 11⁄2 11⁄8 300 14 * With safety factor of 5. APPROVALS 14 For the most up to date information, visit www.itwbuildex.com Part Number Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs)UL Min Thickness FM Max Pipe Size FM Test Load (lbs)FM Min Thickness SAMMYS FOR WOOD – PIPE HANGER Min Wood Thickness Min Wood Thickness 8007957 GST 10 3/8"Vertical CPVC 1-1/2"300 1-1/2" 8020957 SWG 10 3/8"Horizontal CPVC 1-1/2"300 1-1/2" 8008957 GST 20 3/8"Vertical 2-1/2"850 1-1/2"4"1475 1-1/2" 8068925 GST 20-SS 3/8"Vertical 2-1/2"850 1-1/2" 8010957 GST 30 3/8"Vertical 4"1500 1-1/2"4"1475 1-1/2" 8009925 GST 25-380 3/8"Vertical 4"1500 1-1/2" 8022925 SWG 25-380 3/8"Horizontal 3-1/2" - 4"*1500 1-1/2" 8021957 SWG 20 3/8"Horizontal 2-1/2" - 3"** 1050 1-1/2" 8073925 SWG 20-SS 3/8"Horizontal 2-1/2"850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45° Angle off Vertical 2-1/2"850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45° Angle off Vertical 4"1500 1-1/2" 8139957 SH-GST 20 3/8" 17° Angle Off Vertical 3"1050 1-1/2"4"1475 1-1/2" SAMMYS FOR STEEL – PIPE HANGER Min Steel Thickness Min Steel Thickness 8038957 DSTR 1 3/8"Vertical 4"1500 .035"4"1475 .105" 8037957 DSTR 1-1/2 3/8"Vertical 4"1500 .035"4"1475 .105" 8039957 DSTR 516 3/8"Vertical 4"1500 .037"4"1475 .105" 8045957 DST 516 3/8"Vertical 4"1500 .188"4"1475 .188" 8046957 TEK 50 3/8"Vertical 4"1500 .250"4"1475 .188" 8055957 SWDR 1 3/8"Horizontal 4"1500 .037"4"1475 .060" 8056957 SWDR 516 3/8"Horizontal 4"1500 .037"4"1475 .060" 8054957 SWDR 1-1/2 3/8"Horizontal 4"1500 .037"4"1475 .060" 8137957 SH-DSTR 1 3/8" 17° Angle off Vertical 4"1500 .035"4"1475 .105" 8268957 SH-TEK 50 3/8"Vertical 70° Angle off Vertical 2-1/2" 4" 850 1500 8150922 XP 20 3/8"Vertical 2-1/2"850 .027"2" 4"940 1475 .029" .105" 8153922 XP 35 3/8"Vertical 4"1500 .060"2” 4” 940 1475 .029" .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2"750 .027"2”635 .029" 8295922 SXP 35 3/8" Vertical or up to 89° 3-1/2"1250 .060"2”635 .029" 8293957 SWXP 35 3/8"Horizontal 3-1/2"1250 .060" SAMMYS FOR CONCRETE – PIPE HANGER 8059957 CST 20 3/8”Vertical 4"1475 3000psi 8061957 SWC 20 3/8”Horizontal 4"1475 3000psi 8150922 XP 20 3/8”Vertical 2-1/2”850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8”Vertical 2-1/2”850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min Steel Thickness SAMMYS FOR STEEL – LUMINAIRE FITTING 8150922 XP 20 3/8”Vertical 185 250 .027” .035” 8153922 XP 35 3/8”Vertical 185 250 .027” .035” 8181922 XP 200 1/4”Vertical 185 250 .027” .035” 8294922 SXP 20 3/8”Vertical 45° 170 80 .027” .027” 8295922 SXP 35 3/8”Vertical 90° 250 80 .060” .060” 8293957 SWXP 35 3/8”Horizontal 80 .060” Part Number Model Rod Size Mount Direction UL Load Rating (lbs) UL Min Steel Thickness Listed Application SAMMYS FOR STEEL – CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8”Horizontal 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4” or 3/8”Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w/ NEC Standards SHEET STEEL GAUGES Gauge No.22 ga 20 ga 18 ga 16 ga 14 ga 12 ga 1/8"3/16"1/4" Nominal Decimal Equivalent .030".036".048".060".075".105".125".188".25" * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” * SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds INSTALLATION INSTRUCTIONS 3 Note: SAMMYS nut drivers have a unique spin off feature which provides a fast and safe installation each time. When the face of the driver comes in contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty is void if other tools (or modified nut drivers) are used for installation. Eye protection should be worn at all times when installing this product WOOD & STEEL INSTALLATION CONCRETE INSTALLATION VERTICAL INSTALLATION VERTICAL INSTALLATION HORIZONTAL INSTALLATION HORIZONTAL INSTALLATION To find a distributor near you, call 800-848-5611 1. Install appropriate Sammy nut driver (as shown on box label) in a 3/8" or ½" portable drill and insert the anchor into the nut driver. 2. Position drill perpendicular to the structural member and begin drilling (DO NOT USE IMPACT OR HAMMER MODE).* 3. When the nut driver spins freely on the cap of the screw, stop drilling and remove. Installation is now complete. • DSTR and SWDR models add retainer nut and hand tighten (torque to 20 in-lbs max) *For Sammys for Steel, use drill speeds as shown below: SAMMY X-PRESS INSTALLATION A. METAL DECK & PURLIN 1. Insert the bit receiver with 25/64" drill bit (p/n 8152910) into the chuck of a minimum 18-volt battery operated drill. 2. Drill the 25/64" hole through the metal deck or purlin at the desired location. 3. Slide the yellow sleeve of the X-Press It 2.0 Tool over the drill bit until it connects to the receiver. 4. With the internally-threaded portion of the anchor (XP 200, XP 20, XP 35, SWXP 35, SXP 20, SXP 35, SXP 2.0, SXP 3.5) positioned inside the socket of the installation tool, secure the square base of the Sammy X-Press within the square recessed guidelines of the installation tool. 5. Fully insert the Sammy X-Press anchor through the pre-drilled hole. 6. While keeping the top of the tool flush with the metal deck or purlin, firmly hold the yellow sleeve of the X-Press-It 2.0 Tool, before pulling the trigger to install the Sammy X-Press anchor. The expandable portion of the anchor will compress and secure the anchor to the metal deck or purlin. Be sure to properly position hand to avoid injury (see installation photos). B. STRUCTURAL CONCRETE OVER METAL DECK (Follow steps 1-6 before pouring concrete) C. NON-STRUCTURAL LIGHTWEIGHT CONCRETE APPLIED OVER METAL DECK, NOT FOR USE WITH AIR DRY DENSITY GREATER THAN 35 PCF (Follow steps 1-6 after the LWC has been applied) 1. Using included 1/4" diameter carbide tip drill bit, predrill the concrete member to a depth of 2", with a hammer drill or rotary hammer set on hammer mode. • For faster concrete installation see available concrete installation kit (8122910) 2. Install appropriate Sammy nut driver (as shown on box label) in a 3/8" or 1/2" portable drill and insert the anchor into the nut driver. 3. Position drill perpendicular to the structural member and begin drilling (DO NOT USE IMPACT OR HAMMER MODE). 4. When the nut driver spins freely on the cap of the screw, stop drilling and remove. Installation is now complete. SAMMYS FOR STEEL SUGGESTED DRILL SPEED (RPM) DSTR1-1/2, TEK 50, TEK 5.0, SDWR 1-1/2, SH-TEK 50 0 - 1800 All Other SAMMYS for Steel 0 - 2500 SAMMY X-PRESS DRILL/DRIVE INSTALLATION A. METAL DECK & PURLIN 1. Insert the X-Press It 2.0 tool into the chuck of a minimum 18-volt battery operated drill. Please note, you will not be required to use the tool’s internal drill bit when installing XPDD anchors. 2. With the internally-threaded portion of the anchor (XPDD 40) positioned inside the socket of the installation tool, secure the square base of the XPDD anchor within the square recessed guidelines of the installation tool. 3. Apply pressure to the drill-point of the XPDD anchor against the metal deck or purlin. Without holding onto the yellow handle, begin drilling into the metal deck or purlin until a hole is formed, allowing the anchor to completely pass through. 4. While keeping the top of the tool flush with the metal deck or purlin, firmly hold the yellow sleeve of the X-Press-It 2.0 Tool, before pulling the trigger to install the Sammy X-Press Drill/Drive anchor. The expandable portion of the anchor will compress and secure the anchor to the metal deck or purlin. Be sure to properly position hand to avoid injury (see installation photos). B. STRUCTURAL CONCRETE OVER METAL DECK (Follow steps 1-4 before pouring concrete) Pre-drill hole Attach X-press It 2.0 Sleeve Insert and lock in X-press Anchor Sammy X-press Drill/Drive Anchor Install by expanding anchor Drill the hole using the self-drilling tip Install by expanding anchor Note: In the process of enhancing our systems, we are transitioning data to a new PiQ data view. This data is being verified with the "Historical" view foraccuracy. Once the data is confirmed, the "Historical" view will be discontinued. During this transition, you may encounter duplicate entries ormissing/outdated data. For queries during this interim period, please visit our Historical View FAQs or contact our Customer Service. COMPANY ITW Commercial Construction Nor th America 155 Harlem Avenue Glenview, IL 60025 United States EX5098   Pipe hangers For Installation into Steel: Model Min Steel Thkns in. Rod Size, in.NPS*Comments SWDR 0.037 3/8 4 Self-drilling anchors for horizontal installation into steel SWDR 516 0.037 3/8 4 Self-drilling anchors for horizontal installation into steel DSTR 1"0.035 3/8 4 Self-drilling anchors for vertical installation into steel DSTR 1- 1/2" 0.035 3/8 4 Self-drilling anchors for vertical installation into steel DST516 0.188 3/8 4 Self-drilling anchors for vertical installation into steel DSTR516 0.037 3/8 4 Self-drilling anchors for vertical installation into steel SH- DSTR-1 0.035 3/8 4 Self-drilling anchors for vertical installation or up to 17 degrees from vertical into steel SH- DSTR-1- SS 0.035 3/8 4 Self-drilling anchors for vertical installationor up to 17 degrees from vertical into steel TEK-50 0.250 3/8 4 Self-drilling anchors for vertical installation into steel Hangers, Pipe 5/29/24, 1:21 PM VFXT.EX5098 - Hangers, Pipe | UL Product iQ https://iq.ulprospector.com/en/profile?e=159482 1/4 X-Press 20 22 gauge 3/8 2- 1/2 Threaded anchors for vertical installation into steel decking, steel decking prior to pouring of structural concrete, and steel decking following pouring of lightweight concrete (not greater than 35 PCF) X-Press 20 M10 22 gauge M10 2 Threaded anchors for vertical installation into steel decking, steel decking prior to pouring of structural concrete, and steel decking following pouring of lightweight concrete (not greater than 35 PCF) X-Press 35 16 gauge 3/8 4 Threaded anchors for vertical installation into steel decking, steel decking prior to pouring of structural concrete, and steel decking following pouring of lightweight concrete (not greater than 35 PCF) SWXP 16 gauge 3/8 3- 1/2 Threaded anchor for horizontal installation into steel decking SXP 20 22 gauge 3/8 2 Threaded anchor for installation into steel deck that is horizontal or up to 45 degrees from horizontal SXP 35 16 gauge 3/8 3- 1/2 Threaded anchor for installation into steel deck that is horizontal or up to 90 degrees from horizontal SH TEK 50 0.125 3/8 2- 1/2 Threaded anchor for installation into steel bar joist that is up to 70 degrees from horizontal SH TEK 50 0.125 3/8 4 Threaded anchor for installation into steel bar joist that is horizontal SAMMY XP DD 40 16 gauge 3/8 Up to 4 Self-drilling anchor for vertical installation into steel decking or steel decking prior to pouring of structural concrete SAMMY XP DD 40 22 gauge 3/8 Up to 2- 1/2 Self-drilling anchor for vertical installation into steel decking or steel decking prior to pouring of structural concrete For Installation into Wood: Model Min Wood Thkns in. Rod Size, in.NPS*Comments SWG25 380 1-1/2 3/8 4 Self-threading anchor for horizontal installation into the side of a wood timber or joist SWG20 1-1/2 3/8 3 Self-threading anchor for horizontal installation into the side of a wood timber or joist SWG20-SS 1-1/2 3/8 3- 1/2 Self-threading anchor for horizontal installation into the side of a wood timber or joist SWG20 1-1/2 3/8 2- 1/2 Self-threading anchor for horizontal installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size SWG20-SS 1-1/2 3/8 2- 1/2 Self-threading anchor for horizontal installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size SWG25- 380 1-1/2 3/8 4 Self-threading anchor for horizontal installation into the side of a wood timber joist, minimum 1-1/2 in. thick. Additionally, for installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 in. thick 5/29/24, 1:21 PM VFXT.EX5098 - Hangers, Pipe | UL Product iQ https://iq.ulprospector.com/en/profile?e=159482 2/4 GST 25- 380 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom of a wood timber or joist GST 30 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom of a wood timber or joist GST 30-SS 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom of a wood timber or joist SH-GST30 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom of a wood timber or joist SH- GST30-SS 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom of a wood timber or joist GST 20 1-1/2 3/8 2- 1/2 Self-threading anchor for vertical installation into the bottom of a wood timber or joist GST 20-SS 1-1/2 3/8 2- 1/2 Self-threading anchor for vertical installation into the bottom of a wood timber or joist SH-GST20 1-1/2 3/8 3 Self-threading anchor for vertical installation into the bottom of a wood timber or joist SH- GST20-SS 1-1/2 3/8 3 Self-threading anchor for vertical installation into the bottom of a wood timber or joist GST 25- 380 1-1/2 3/8 4 Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size GST 20 1-1/2 3/8 2- 1/2 Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size GST 20-SS 1-1/2 3/8 2- 1/2 Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size SH-GST/ CST 20 1-1/2 3/8 4 Threaded anchor for installation into wood, 1.5 in. nominal thickness that is horizontal SH-GST/ CST 20 1-1/2 3/8 2- 1/2 Threaded anchor for installation into wood, 1.5 in. nominal thickness that is up to 45 degrees from horizontal   Concrete Anchors Model Hanger Type Rod Size, in.NPS*Comments TruBolt+Expansion Anchor 3/8 Up to 4   TruBolt+Expansion Anchor 1/2 Up to 8   TruBolt+Expansion Anchor 5/8 Up to 12   TruBolt+Expansion Anchor 3/4 Up to 12   * NPS = Nominal pipe size   5/29/24, 1:21 PM VFXT.EX5098 - Hangers, Pipe | UL Product iQ https://iq.ulprospector.com/en/profile?e=159482 3/4 Last Updated on 2023-07-27 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service. Always look for the Mark on the product. UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2024 UL LLC." 5/29/24, 1:21 PM VFXT.EX5098 - Hangers, Pipe | UL Product iQ https://iq.ulprospector.com/en/profile?e=159482 4/4 PH-1.18 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: RING HANGERS FIG. 69: DIMENSIONS (IN) • LOADS (LBS) • WEIGHT (LBS) Pipe Size Max Load Weight Rod Size A B C F G Width 1⁄2 300 0.10 3⁄8 27⁄8 2 19⁄16 5/8 3⁄4 0.10 23⁄4 17⁄8 15⁄16 1 0.10 29⁄16 111⁄16 1 11⁄4 0.10 25⁄8 13⁄4 7⁄811⁄2 0.10 23⁄4 17⁄8 2 0.11 31⁄4 23⁄8 11⁄8 21⁄2 525 0.20 4 23⁄4 15⁄16 3/4 3 0.20 313⁄16 215⁄16 13⁄16 4 650 0.30 411⁄16 313⁄16 19⁄165 1,000 0.54 1⁄2 55⁄16 43⁄8 6 0.65 611⁄16 59⁄16 21⁄4 8 1.00 89⁄16 79⁄16 31⁄4 Fig. 69 (Formerly Afcon Fig. 300) Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range: 1⁄2" through 8" Material: Carbon steel Finish: Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 450° F Approvals: Complies with Federal Specification A-A-1192A (Type 10), WW-H-171-E (Type 10), and ANSI/MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes 3⁄4" - 8"). Features: • 1/2" - 2" sizes designed for use with steel and CPVC piping and manufactured with FBC System Compatible oil. • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1⁄2" through 6" sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering: Specify size, figure number and name. Non-captured nut also available upon request. 21/2" through 8" Size 1/2" through 2" Size Rounded Edge Design 21/2" through 8" pipe1/2" through 1" pipe 1 1/4" through 2" pipe B C F CL G A B C CL G A F A BCF CL G Model 041 U Bolt Threaded Mechanical Tee FNPT Bulletin 940 April 2022 www.reliablesprinkler.com Nominal Size Hole Saw Size in (mm) Bolt Size in Bolt Torque lbs-ft / N-M Dimensions Weight lb (kg)Run Pipe in (mm) Threaded Outlet in (mm) A in/mm B in/mm C in/mm Take Out T in/mm 1-1/4 (32) 1/2 (15)1-3/16 (30)3/8 22-29 (30-40)2-1/8 (53)3-1/2 (89)2-3/16 (56)1-3/4 (44)0.90 (0.41) 3/4 (20)1-3/16 (30)3/8 22-29 (30-40)2-1/8 (53)3-1/2 (89)2-3/16 (56)1-3/4 (44)0.95 (0.43) 1 (25)1-3/16 (30)3/8 22-29 (30-40)2-3/16 (56)3-1/2 (89)2-3/16 (56)1-7/8 (47)0.95 (0.43) 1-1/2 (40) 1/2 (15)1-3/16 (30)3/8 22-29 (30-40)2-3/16 (55)3-1/2 (89)2-3/16 (56)1-13/16 (46)0.90 (0.41) 3/4 (20)1-3/16 (30)3/8 22-29 (30-40)2-3/16 (55)3-1/2 (89)2-3/16 (56)1-13/16 (46)0.93 (0.42) 1 (25)1-3/16 (30)3/8 22-29 (30-40)2-1/4 (58)3-1/2 (89)2-3/16 (56)1-15/19 (49)0.99 (0.45) 2 (50) 1/2 (15)1-3/16 (30)3/8 22-29 (30-40)2-1/2 (64)3-7/8 (98)2-3/16 (56)2-1/16 (53)0.93 (0.42) 3/4 (20)1-3/16 (30)3/8 22-29 (30-40)2-1/2 (64)3-7/8 (98)2-3/16 (56)2-1/16 (53)0.97 (0.44) 1 (25)1-3/16 (30)3/8 22-29 (30-40)2-5/8 (67)3-7/8 (98)2-3/16 (56)2-3/16 (56)0.97 (0.44) 2-1/2 (65) 1/2 (15)1-3/16 (30)3/8 22-29 (30-40)2-3/4 (69)4-3/8 (111)2-3/16 (56)2-1/4 (58)1.28 (0.58) 3/4 (20 )1-3/16 (30)3/8 22-29 (30-40)2-3/4 (69)4-3/8 (111)2-3/16 (56)2-1/4 (58)1.28 (0.58) 1 (25)1-3/16 (30)3/8 22-29 (30-40)2-13/16 (72)4-3/8 (111)2-3/16 (56)2-3/8 (61)1.32 (0.60) 3 (80)1 (25)1-3/16 (30)3/8 22-29 (30-40)3-3/16 (81)5-1/16 (128)2-3/16 (56)2-5/8 (67)1.32 (0.60) Table A cULus Listed, FM Approved 300 psi (20.7 bar) 041 U Bolt Threaded Mechanical Tee FNPT Technical Data Operating Specifications Maximum Working Pressure: 300 psi (20.7 bar) Operating Temperature -30 °F to 230 °F (-34 °C to 110 °C) Material Specifications Housings: ASTM A536 Grade 65-45-12 Ductile Iron Gasket: Grade E EDPM Bolt Specification: SAE J429 Grade 5 Thread Specification: ASME B1.20.1 Available Finishes Housing: Standard orange paint Hot dipped galvanized (ASTM A-153) Listings and Approvals cULus Listed FM Approved 041 U Bolt Threaded Mechanical Tee FNPT Dimensions Figure 1 Nominal Size in (mm)Pipe Approvals 1-1/4 (32)10 cULus, FM40 1-1/2 (40)10 cULus, FM40 2 (50)10 cULus, FM40 2-1/2 (65)10 cULus, FM40 3 (80)10 cULus, FM40 Table B041 Pipe Compatibility Bulletin 940 April 2022 Page 2 of 2 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 6 5 3 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: For Fire Protection & Other Low Pressure Piping Systems Welded Outlet Fittings SPF-8.14 SPF Welded Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings specifically designed and manufactured to be installed on proprietary thin wall flow pipe, Schedule 5, 10, and 40 standard wall pipes. SPF Welded Outlets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53. SPF Welded Outlet Fittings employ a low weld volume design to provide either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Threads comply with ANSI B1.20.1. The SPF Welded Outlets are UL Listed and FM Approved for use conforming to the requirements of NFPA 13. SPF Welded Outlet Fittings are rated for 300 psi when used in fire sprinkler system applications. SPF WELDED OUTLET FITTINGS Outlet Model Outlet Pipe Size Header Pipe Size Rated Pressure In.In.psig MTM-40 1⁄2, 3⁄4, 1 1⁄2 - 8 (Sch.10, 40) 30011⁄4, 11⁄2, 2, 21⁄2, 3, 4 1⁄2 - 4 (Sch. 5, DynaFlow) 2 4, 6 (EZ-Flow) GR-40 1 - 8 11⁄4 - 8 (Sch.10, 40)30021⁄2 - 8 21⁄2 - 8 (Sch. 5, DynaFlow) For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. 1) Size-on size (i.e. 2 x 2) SPF Welded Outlet Fittings are not FM Approved. 2) FM rated working pressure when welded on Sch. 5 or lightwall pipe is 175 psi. 3) Refer to the UL and FM websites for the most current pressure ratings. Welded Outlet Fittings SPF-2.17 SPF Welded Outlets are designed and Manufac- tured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the installation. SPF Welded Outlets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: • The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: • The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll-off, burn- through or excessive distortion. • On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. • Each outlet size 11⁄2" and larger, whether female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. GENERAL SPECIFICATIONS • Welded outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install SPF Welded Outlets. • Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads. • SPF Welded Outlets threaded and grooved welding outlet fittings are UL/ULC Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. • SPF Welded Outlets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. • SPF Welded Outlets are identified by a lot number that provides full traceability. FOR YOUR PIPING SYSTEMS SPECIFY SPF WELDED OUTLETS Branch Outlet Fittings shall be SPF Welded Outlets, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1 and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA 13, and pressure rated for 300 PSI maximum. Welded Outlet Fittings SPF-2.17 D C M A B MTM-40 Female Thread Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Make Up M Weight Each In./mm In./mm In./mm In./mm In./mm Lbs./kg 1⁄2 x 13 x 11⁄4 - 11⁄2 1.063 0.700 0.500 0.171 32 - 40 27.0 17.8 12.7 0.08 11⁄2 - 2 1.063 0.700 0.500 0.171 40 - 50 27.0 17.8 12.7 0.08 2 - 21⁄2 1.063 0.700 0.500 0.171 50 - 65 27.0 17.8 12.7 0.08 21⁄2 - 8 1.063 0.700 0.500 0.169 65 - 200 27.0 17.8 12.7 0.08 3⁄4 x 19 x 11⁄4 - 11⁄2 1.125 0.900 0.500 0.260 32 - 40 28.6 22.9 12.7 0.12 11⁄2 - 2 1.125 0.900 0.500 0.260 40 - 50 28.6 22.9 12.7 0.12 2 - 21⁄2 1.125 0.900 0.500 0.260 50 - 65 28.6 22.9 12.7 0.12 21⁄2 - 8 1.125 0.900 0.500 0.256 65 - 200 28.6 22.9 12.7 0.12 1 x 25 x 11⁄4 - 11⁄2 1.250 1.145 0.500 0.331 32 - 40 31.8 29.1 12.7 0.15 11⁄2 - 2 1.250 1.145 0.500 0.331 40 - 50 31.8 29.1 12.7 0.15 2 - 21⁄2 1.250 1.145 0.500 0.320 50 - 65 31.8 29.1 12.7 0.15 21⁄2 - 3 1.250 1.145 0.500 0.314 65 - 80 31.8 29.1 12.7 0.14 3 - 4 1.250 1.145 0.500 0.309 80 - 100 31.8 29.1 12.7 0.14 5 - 8 1.250 1.145 0.500 0.291 125 - 200 31.8 29.1 12.7 0.13 11⁄4 x 32 x 11⁄4 - 11⁄2 1.375 1.490 0.500 0.432 32 - 40 34.9 37.8 12.7 .019 11⁄2 - 2 1.375 1.490 0.500 0.421 40 - 50 34.9 37.8 12.7 .019 2 - 21⁄2 1.375 1.490 0.500 0.421 50 - 65 34.9 37.8 12.7 .019 21⁄2 - 3 1.375 1.490 0.500 0.411 65 - 80 34.9 37.8 12.7 .019 3 - 4 1.375 1.490 0.500 0.389 80 - 100 34.9 37.8 12.7 .018 5 - 8 1.375 1.490 0.500 0.389 125 - 200 34.9 37.8 12.7 .018 11⁄2 x 40 x 11⁄2 1.625 1.610 0.875 0.477 40 41.3 40.9 22.2 .022 2 1.625 1.610 0.875 0.477 50 41.3 40.9 22.2 .022 21⁄2 1.625 1.610 0.875 0.477 65 41.3 40.9 22.2 .022 3 - 4 1.625 1.610 0.875 0.477 80 - 100 41.3 40.9 22.2 .022 4 1.625 1.610 0.875 0.477 100 41.3 40.9 22.2 .022 5 - 8 1.625 1.610 0.875 0.477 125 - 200 41.3 40.9 22.2 .022 Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Make Up M Weight Each In./mm In./mm In./mm In./mm In./mm Lbs./kg 2 x 50 x 2 1.750 2.067 0.875 0.857 50 44.5 52.5 22.2 0.38 21⁄2 1.750 2.067 0.875 0.829 65 44.5 52.5 22.2 0.38 3 1.750 2.067 0.875 0.829 80 44.5 52.5 22.2 0.39 4 1.750 2.067 0.875 0.800 100 44.5 52.5 22.2 0.36 6 1.750 2.067 0.875 0.743 150 44.5 52.5 22.2 0.34 8 1.750 2.067 0.875 0.743 200 44.5 52.5 22.2 0.34 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. SPF WELDED OUTLETS - MTM-40 Welded Outlet Fittings SPF-2.17 GR-40 Cut Groove Standard Weight E C B A F D Note: Welded Outlets are manufactured to fit size-on-size, that is the contoured shape on a given Welded Outlet is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting, a slight gap of approximately 1⁄32" will appear along the longitudinal centerline of the header. For example, a 1" x 2 - 21⁄2" Welded Outlet, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1⁄32" gap along the longitudinal centerline of the 21⁄2" size. If a perfect fit is required for a 21⁄2" header pipe, then a 1" x 21⁄2 - 3" Welded Outlet would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. (Additional larger sizes on next page.) Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Outside Diameter E Wall Thickness F In./mm In./mm In./mm In./mm In./mm In./mm 11⁄4 x 32 x 11⁄4 3 1.368 1.660 0.140 32 80 34.7 42.2 3.6 11⁄2 3 1.368 1.660 0.140 40 80 34.7 42.2 3.6 2 - 21⁄2 3 1.368 1.660 0.140 50 - 65 80 34.7 42.2 3.6 3 - 4 3 1.368 1.660 0.140 80 - 100 80 34.7 42.2 3.6 5 - 8 3 1.368 1.660 0.140 125 - 200 80 34.7 42.2 3.6 11⁄2 x 40 x 11⁄2 3 1.610 1.900 0.145 40 80 40.9 48.3 3.7 2 3 1.610 1.900 0.145 50 80 40.9 48.3 3.7 21⁄2 3 1.610 1.900 0.145 65 80 40.9 48.3 3.7 3 - 4 3 1.610 1.900 0.145 80 - 100 80 40.9 48.3 3.7 5 - 8 3 1.610 1.900 0.145 125 - 200 80 40.9 48.3 3.7 2 x 50 x 2 3 2.067 2.375 0.154 50 80 52.5 60.3 3.9 21⁄2 3 2.067 2.375 0.154 65 80 52.5 60.3 3.9 3 3 2.067 2.375 0.154 80 80 52.5 60.3 3.9 4 3 2.067 2.375 0.154 100 80 52.5 60.3 3.9 6 3 2.067 2.375 0.154 150 80 52.5 60.3 3.9 8 3 2.067 2.375 0.154 200 80 52.5 60.3 3.9 SPF WELDED OUTLETS - GR-40 (Nominal Sizes 11/4" thru 8") Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter - D Outside Diameter E Wall Thickness - F Standard Weight Schedule 10 Standard Weight Schedule 10 In./mm In./mm In./mm In./mm In./mm In./mm In./mm In./mm 21⁄2 x 65 x 21⁄2 3 2.469 2.635 2.875 0.203 0.120 65 80 62.7 67.0 76.2 5.0 3.0 4 3 2.469 2.635 2.875 0.203 0.120 100 80 62.7 67.0 76.2 5.0 3.0 6 3 2.469 2.635 2.875 0.203 0.120 175 80 62.7 67.0 76.2 5.0 3.0 8 3 2.469 2.635 2.875 0.203 0.120 200 80 62.7 67.0 76.2 5.0 3.0 3 x 80 x 3 3 3.068 3.260 3.500 0.216 0.120 80 80 78.0 83.0 88.0 5.0 3.0 4 3 3.068 3.260 3.500 0.216 0.120 100 80 78.0 83.0 88.0 5.0 3.0 6 3 3.068 3.260 3.500 0.216 0.120 150 80 78.0 83.0 88.0 5.0 3.0 8 3 3.068 3.260 3.500 0.216 0.120 200 80 78.0 83.0 88.0 5.0 3.0 4 x 100 x 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 108.0 114.0 6.0 3.0 6 4 4.026 4.260 4.500 0.237 0.120 150 100 102.0 108.0 114.0 6.0 3.0 8 4 4.026 4.260 4.500 0.237 0.120 200 100 102.0 108.0 114.0 6.0 3.0 6 x 150 x 6 4 6.065 6.357 6.625 0.280 0.134 150 100 155.0 161.5 168.3 7.1 3.0 8 4 6.065 6.357 6.625 0.280 0.134 200 100 155.0 161.5 168.3 7.1 3.0 8 x 200 x 8 4 7.981 8.329 8.625 0.322 0.148 200 100 203.0 212.0 213.0 8.0 3.0 Welded Outlet Fittings SPF-8.14 Tapered hole matches pitch line of thread leaving a fully formed female thread. Pitch Line Welded Outlet Wrench Tight L3 Effective Thread L2 Hand Tight L1 Vanish Threads V Male Pipe Pitch Female Wrench Tight L3 Effective Thread L2 Vanish Threads V Male Pipe Standard tap drill leaves excess truncation on L3 threads. SPF NPT THREAD FORM STANDARD NPT THREAD FORM Welding Practice When measured with respect to linear inches of weld required for installation, SPF Welded Outlets require up to 15% less weld than competitive fittings. This reduces time and savings over time are substantial. The diameter of the contoured end of Welded Outlet has been reduced so that the wall thickness more nearly matches the header or branch line pipe wall thickness. There- fore, current and voltage settings required for welding are set to provide for adequate penetration without burn through and cold shutting. Also, weld volume required for installation is lower for SPF Welded Outlets than most other fittings. Typically, SPF Welded Outlets require one-weld pass for attachment. WELDING PRACTICE Outlet Size SPF WELDED OUTLETS COMPETITIVE FITTING WELD VOLUME*LINEAR WELDING WELD VOLUME* LINEAR WELDING In. (mm) Cross Sec. Area %less In.(mm)%less Cross Sec. Area %more In.(mm)%less 1" 0.051 sq. in. 12% 2.48 0% 0.058 sq. in. 12% 2.48 0% 25 32.9 sq mm 62.9 37.4 sq mm 62.9 11⁄4" 0.032" 48% 2.88 4% 0.063 48% 3.01 4% 32 20.6 73.1 40.6 76.4 11⁄2" 0.036" 40% 3.12 10% 0.060 40% 3.46 10% 40 23.2 79.2 38.7 87.8 2" 0.040" 62% 3.77 15% 0.106 62% 4.41 15% 50 25.8 95.7 68.3 112.0 .205" 2.650" 2" SPF Welded Outlet .065" .325" 2.820" 2" Competitive Fitting .180" Threading Practice SPF Welded Outlets thread form is consistent with Aeronautical National Form (ANPT) AS71051. The thread is fully formed over both the L-1 hand tight and L-3 wrench tight threads. NPT tapered threads are typically gauged only over the L-1 threads. This makes SPF Welded Outlets more forgiving of field cut threaded pipe that may only marginally conform to the specifi- cation. Fewer leaks translate into lower costs. Ease of Installation SPF Welded Outlets are designed to sit higher on the pipe, thereby requiring less weld and eliminating burn through. SPF Welded Outlets sit higher on the header or branch line pipe than competitive fittings. This allows the welding torch to remain in an optimum position for welding. In addition, 11/2" and larger female threaded and grooved welded outlets require the same hole size for installation. This results in fewer change overs when installed using automatic welders. NPT TAPERED PIPE THREADS Drop Nipple or Tee-Let Outlet Size L1 Hand Tight L3 Wrench Tight Total L1 - L3 Length L2 Effective Threads In./mm In./mm Threads In./mm Threads In./mm Threads In./mm Threads 1⁄2 0.320 4.48 0.214 3.00 0.534 7.48 0.534 7.4715 8.1 5.4 13.6 13.6 3⁄4 0.339 4.75 0.214 3.00 0.553 7.75 0.546 7.6420 8.6 5.4 14.0 13.9 1 0.400 4.60 0.261 3.00 0.661 7.60 0.683 7.8525 10.2 6.6 16.8 17.3 11⁄4 0.420 4.83 0.261 3.00 0.681 7.83 0.707 8.1332 10.7 6.6 17.3 18.0 11⁄2 0.420 4.83 0.261 3.00 0.697 7.83 0.724 8.3240 10.7 6.6 17.7 18.4 2 0.436 5.01 0.261 3.00 0.706 8.01 0.757 8.7050 11.1 6.6 17.9 19.2 21⁄2 0.682 5.46 0.250 2.00 0.932 7.46 1.138 9.1065 17.3 6.4 23.7 28.9 3 0.766 6.13 0.250 2.00 1.016 8.13 1.200 9.6080 19.5 6.4 25.8 30.5 4 0.844 6.75 0.250 2.00 1.094 8.75 1.300 10.40100 21.4 6.4 27.8 33.0 Welded Outlet Fittings SPF-8.14 RECOMMENDED OUTLET HOLE SIZES Welded OutletSize Type Recommended Hole Size In./mm In./mm 1⁄2 MTM-40 5⁄8 13 16 3⁄4 MTM-40 7⁄8 19 22 1 MTM-40 11⁄8 25 28 11⁄4 MTM-40 11⁄2 31 38 11⁄4 GR-40 13⁄8 31 35 11⁄2 MTM-40 or GR-40 15⁄8 38 41 2 MTM-40 or GR-40 2 50 50 21⁄2 GR-40 27⁄16 63 61 3 GR-40 3 75 75 4 GR-40 4 100 100 1⁄2, 3⁄4 & 1 Outlet 11⁄4 - 2 Outlet B ARecommended Installation Procedures SPF Welded Outlet Fittings are designed and manufactured to reduce the cost of installation from both the standpoint of labor required and energy consumed. In addition, by following the recommended installation procedures, many of the problems associated with installing welding outlet fittings on standard weight or light weight pipe are eliminated, including burn through and excessive shrinkage resulting in pipe distortion. Recommended Hole Sizes The hole cut in the branch or header pipe can be cut prior or subsequent to attachment of the Welded Outlets. One advantage of cutting the hole after welding is that the pipe is left intact during welding, thereby, reducing shrinkage and possible distortion. If holes are cut prior to welding, as some codes require, then the following hole sizes are recommended. Recommended Welding Procedures SPF Welded Outlet Fittings are designed to be installed on standard weight or light weight pipe with one weld pass on sizes through 4”. Moreover, the wall thickness at the weld end of the fitting approximately matches standard weight pipe. Accordingly, heat settings can be made to optimize penetration on both the fitting and the pipe which it is being welded. Aside from reducing the likelihood of burn through and distortion resulting from excessive heat, the amount of weld required for adequate penetration is significantly reduced. As a general rule, the weld should be only as hot as required to allow the weld to penetrate the materials being welded while concomitantly allowing gases developed in the welding process to escape. Every effort must be made to avoid welding too hot or overheating both the pipe and the Welded Outlets. Excessive heat may cause the wrench tight threads (those in the bottom of the Welded Outlets near the weld zone) to distort while also causing the branch pipe to bend. It should be noted that SPF Welded Outlet Fittings have been subjected to exhaustive testing and evaluation, and only negligibly distort when subjected to excessive heat. The threads, on the other hand, may not return to their gauged form after cooling if excessive heat causes them to expand. The following is intended only as a guide, and assumes that the welding equipment is properly calibrated and functioning normally and the operator is qualified. RECOMMENDED AMOUNT OF WELD Outlet Size A B In./mm In./mm In./mm 1 1⁄4 3⁄16 25 7 5 11⁄4 1⁄4 3⁄16 31 7 5 11⁄2 5⁄16 1⁄4 38 8 7 2 5⁄16 1⁄4 50 8 7 21⁄2 5⁄16 1⁄4 63 8 7 3 3⁄8 5⁄16 75 10 8 4 3⁄8 5⁄16 100 10 8 Note: Please refer to www.anvilintl.com or latest catalog for recommended hole size and welding practice. Holes may be cut employing mechanical means – including hole sawing, mechanical flame cutting (oxy-acetylene or propane), and air plasma cutting (constricted tungsten arc) machines. Anvil offers a simple approach to cutting the hole. Hand–held templates are sized to match your plasma cutter. Welded Outlet Fittings SPF-8.14 RECOMMENDED SETTINGS FOR MICROWIRE WELDING PROCESS Header Size Pipe Wall Thickness Welded OutletMTM-40 & GR-40 Electrode Size Welding Current Arc. Volts Wire Feed Travel Speed In./mm In./mm In./mm AMPS-DC POS.IPM IPM 11⁄4 - 2 31-50 0.065 2 1⁄2 - 2 0.035 100-130 16-20 210 25-30 13-50 21⁄2 - 4 0.035 115-150 17-21 270 20-25 63-100 0.109 3 1⁄2 - 2 0.035 110-140 18-22 220 25-30 13-50 21⁄2 - 4 0.035 120-160 19-22 290 20-25 63-100 21⁄2 - 4 63-100 0.083 2.5 1⁄2 - 2 0.035 110-140 17-20 210 20-25 13-50 21⁄2 - 4 0.035 120-150 17-20 270 20-25 63-100 0.120 3 1⁄2 - 2 0.035 120-160 19-22 290 20-25 13-50 21⁄2 - 4 0.035 130-160 19-22 240 20-25 63-100 5-6 125-150 0.109 3 1⁄2 - 2 0.035 120-150 17-20 210 20-25 13-50 21⁄2 - 4 0.035 130-150 18-20 270 15-20 63-100 0.134 3.5 1⁄2 - 2 0.035 130-160 19-22 290 20-25 13-50 21⁄2 - 4 0.035 140-160 20-22 270 15-20 63-100 21⁄2 - 4 0.045 180-205 20-24 245 27-32 63-100 8 200 0.109 3 1⁄2 - 2 0.035 120-150 17-20 240 20-25 13-50 21⁄2 - 4 0.035 130-150 18-20 260 15-20 63-100 21⁄2 - 4 0.045 170-220 18-22 290 12-18 63-100 0.148 3.5 1⁄2 - 2 0.035 130-160 19-22 240 20-25 13-50 21⁄2 - 4 0.035 140-160 20-22 260 15-20 63-100 21⁄2 - 4 0.045 180-225 20-24 290 12-18 63-100 Anvil assumes no liability for any consequential damages resulting from the improper use of its Welded Outlet Fittings, nor for any recommendations made with respect to installation procedures. Shielding Gas Flow (for all sizes) 20-25 CfH 1) Co2 - Deeper penetration, faster welding, low cost. 2) 25% - Argon, 75% - Co2, Recommended for .134 wall and lighter, high welding speeds without melt through, minimum distortion and spatter, good penetration. www.titusindustrial.com CAST IRON FIRE PROTECTION TECHNICAL BULLETINS 2 TABLE OF CONTENTS 90° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 90° REDUCED ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 45° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 REDUCED COUPLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 CROSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 REDUCED CROSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 REDUCED TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 PLUG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 CAST IRON 90° ELBOW ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 3 CAST IRON 90° ELBOW ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪For current listing/approval details contact a Titus representative Pressure Unit WT PSI/MPa A B LB/KGS 300 1.50 1.50 0.90 2065 38.1 38.1 0.41 300 1.75 1.75 1.39 2065 44.45 44.45 0.63 300 1.94 1.94 1.83 2065 49.27 49.27 0.83 300 2.25 2.25 3.10 2065 57.15 57.15 1.41 300 2.70 2.70 4.80 2065 68.58 68.58 2.18 2-1/2 CB90044 CB90055 CB90033 CB90066 CB9007765 1-1/2 40 2 50 1 25 1-1/4 32 CODE DimensionNominal Size in/mm CAST IRON 28 90° ELBOW ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪For current listing/approval details contact a Titus representative Pressure Unit WT PSI/MPa A B LB/KGS 300 1.50 1.50 0.90 2065 38.1 38.1 0.41 300 1.75 1.75 1.39 2065 44.45 44.45 0.63 300 1.94 1.94 1.83 2065 49.27 49.27 0.83 300 2.25 2.25 3.10 2065 57.15 57.15 1.41 300 2.70 2.70 4.80 2065 68.58 68.58 2.18 2-1/2 CB90044 CB90055 CB90033 CB90066 CB9007765 1-1/2 40 2 50 1 25 1-1/4 32 CODE DimensionNominal Size in/mm CAST IRON 28 90° REDUCED ELBOW ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 4 CAST IRON A B 300 1.26 1.36 0.68 2065 32.0 34.5 0.31 300 1.37 1.45 0.77 2065 34.80 36.83 0.35 300 1.34 1.53 0.97 2065 34.04 38.86 0.44 300 1.45 1.62 1.08 2065 36.83 41.15 0.49 300 1.58 1.67 1.19 2065 40.13 42.42 0.54 300 1.41 1.66 1.17 2065 35.8 42.2 0.53 300 1.52 1.75 1.30 2065 38.61 44.45 0.59 300 1.65 1.80 1.43 2065 41.91 45.72 0.65 300 1.82 1.88 1.65 2065 46.23 47.75 0.75 300 1.49 1.88 1.72 2065 37.85 47.75 0.78 300 1.60 1.97 1.85 2065 40.6 50.0 0.84 300 1.73 2.02 2.00 2065 43.94 51.31 0.91 300 1.90 2.10 2.31 2065 48.26 53.34 1.05 300 2.02 2.16 2.53 2065 51.31 54.86 1.15 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS 1×1/2 CB9003125×15 1×3/4 CB9003225×20 1-1/4×1/2 CB9004132×15 1-1/4×3/4 CB9004232×20 1-1/4×1 CB9004332×25 1-1/2×1/2 CB9005140×15 1-1/2×3/4 CB9005240×20 1-1/2×1 CB9005340×25 1-1/2×1/-1/4 CB9005440×32 2×1/2 CB9006150×15 2×3/4 CB9006250×20 2×1 CB9006350×25 2×1-1/4 CB9006450×32 2×1-1/2 CB9006550×40 A B 300 1.26 1.36 0.68 2065 32.0 34.5 0.31 300 1.37 1.45 0.77 2065 34.80 36.83 0.35 300 1.34 1.53 0.97 2065 34.04 38.86 0.44 300 1.45 1.62 1.08 2065 36.83 41.15 0.49 300 1.58 1.67 1.19 2065 40.13 42.42 0.54 300 1.41 1.66 1.17 2065 35.8 42.2 0.53 300 1.52 1.75 1.30 2065 38.61 44.45 0.59 300 1.65 1.80 1.43 2065 41.91 45.72 0.65 300 1.82 1.88 1.65 2065 46.23 47.75 0.75 300 1.49 1.88 1.72 2065 37.85 47.75 0.78 300 1.60 1.97 1.85 2065 40.6 50.0 0.84 300 1.73 2.02 2.00 2065 43.94 51.31 0.91 300 1.90 2.10 2.31 2065 48.26 53.34 1.05 300 2.02 2.16 2.53 2065 51.31 54.86 1.15 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS 1×1/2 CB9003125×15 1×3/4 CB9003225×20 1-1/4×1/2 CB9004132×15 1-1/4×3/4 CB9004232×20 1-1/4×1 CB9004332×25 1-1/2×1/2 CB9005140×15 1-1/2×3/4 CB9005240×20 1-1/2×1 CB9005340×25 1-1/2×1/-1/4 CB9005440×32 2×1/2 CB9006150×15 2×3/4 CB9006250×20 2×1 CB9006350×25 2×1-1/4 CB9006450×32 2×1-1/2 CB9006550×40 45° ELBOW ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 5 CAST IRON A B 300 1.120 1.120 0.81 2065 28.448 28.448 0.37 300 1.290 1.290 1.23 2065 32.766 32.766 0.56 300 1.430 1.430 1.65 2065 36.322 36.322 0.75 300 1.680 1.680 2.68 2065 42.672 42.672 1.22 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS 1 CB4503325 1-1/4 CB4504432 1-1/2 CB4505540 2 CB4506650 A B 300 1.120 1.120 0.81 2065 28.448 28.448 0.37 300 1.290 1.290 1.23 2065 32.766 32.766 0.56 300 1.430 1.430 1.65 2065 36.322 36.322 0.75 300 1.680 1.680 2.68 2065 42.672 42.672 1.22 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS 1 CB4503325 1-1/4 CB4504432 1-1/2 CB4505540 2 CB4506650 REDUCED COUPLING ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 6 CAST IRON Dimension A 300 1.70 0.616 2065 43.18 0.28 300 1.70 0.684 2065 43.18 0.311 Nominal Size in/mm CODE Pressure PSI/MPa Unit WT LB/KGS 1×1/2 CRC03125×15 1×3/4 CRC03225×20 Dimension A 300 1.70 0.616 2065 43.18 0.28 300 1.70 0.684 2065 43.18 0.311 Nominal Size in/mm CODE Pressure PSI/MPa Unit WT LB/KGS 1×1/2 CRC03125×15 1×3/4 CRC03225×20 CROSS ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 7 CAST IRON A B 300 1.50 1.50 1.60 2065 38.1 38.1 0.73 300 1.75 1.75 2.64 2065 44.45 44.45 1.20 300 1.94 1.94 2.99 2065 49.27 49.27 1.36 300 2.25 2.25 4.80 2065 57.15 57.15 2.18 1-1/2 CX05540 2 CX06650 1 CX03325 1-1/4 CX04432 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGSAB 300 1.50 1.50 1.60 2065 38.1 38.1 0.73 300 1.75 1.75 2.64 2065 44.45 44.45 1.20 300 1.94 1.94 2.99 2065 49.27 49.27 1.36 300 2.25 2.25 4.80 2065 57.15 57.15 2.18 1-1/2 CX05540 2 CX06650 1 CX03325 1-1/4 CX04432 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS REDUCED CROSS ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 8 CAST IRON A B 300 1.58 1.67 1.89 2065 40.13 42.42 0.86 300 1.65 1.80 2.27 2065 41.91 45.72 1.03 300 1.73 2.02 2.99 2065 43.94 51.31 1.36 2×1 CX06350×25 1-1/4×1 CX04332×25 1-1/2×1 CX05340×25 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGSAB 300 1.58 1.67 1.89 2065 40.13 42.42 0.86 300 1.65 1.80 2.27 2065 41.91 45.72 1.03 300 1.73 2.02 2.99 2065 43.94 51.31 1.36 2×1 CX06350×25 1-1/4×1 CX04332×25 1-1/2×1 CX05340×25 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS TEE ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 9 CAST IRON A B 300 1.50 1.50 1.25 2065 38.10 38.10 0.57 300 1.75 1.75 1.91 2065 44.45 44.45 0.87 300 1.94 1.94 2.55 2065 49.27 49.27 1.16 300 2.25 2.25 3.96 2065 57.15 57.15 1.80 300 2.70 2.70 6.38 2065 68.58 68.58 2.90 Pressure PSI/MPa Dimension Unit WT LB/KGS 1 CT33325 2-1/2 CT77765 Nominal Size in/mm CODE 1-1/4 CT44432 1-1/2 CT55540 2 CT66650 A B 300 1.50 1.50 1.25 2065 38.10 38.10 0.57 300 1.75 1.75 1.91 2065 44.45 44.45 0.87 300 1.94 1.94 2.55 2065 49.27 49.27 1.16 300 2.25 2.25 3.96 2065 57.15 57.15 1.80 300 2.70 2.70 6.38 2065 68.58 68.58 2.90 Pressure PSI/MPa Dimension Unit WT LB/KGS 1 CT33325 2-1/2 CT77765 Nominal Size in/mm CODE 1-1/4 CT44432 1-1/2 CT55540 2 CT66650 REDUCED TEE ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative A B C 300 1.50 1.36 1.50 1.06 2065 38.10 34.54 38.10 0.48 300 1.50 1.45 1.50 1.10 2065 38.10 36.83 38.10 0.50 300 1.26 1.26 1.36 0.97 2065 32.00 32.00 34.54 0.44 300 1.37 1.37 1.45 1.08 2065 34.80 34.80 36.83 0.49 300 1.67 1.67 1.58 1.45 2065 42.42 42.42 40.13 0.66 300 1.80 1.80 1.65 1.72 2065 45.72 45.72 41.91 0.78 300 1.34 1.26 1.53 1.19 2065 34.04 32.00 38.86 0.54 300 1.45 1.37 1.62 1.34 2065 36.83 34.80 41.15 0.61 300 1.58 1.50 1.67 1.45 2065 40.13 38.10 42.42 0.66 300 1.75 1.67 1.75 1.78 2065 44.45 42.42 44.45 0.81 300 1.88 1.80 1.82 1.94 2065 47.75 45.72 46.23 0.88 300 1.34 1.34 1.53 1.36 2065 34.04 34.04 38.86 0.62 300 1.45 1.45 1.62 1.41 2065 36.83 36.83 41.15 0.64 300 1.58 1.58 1.67 1.63 2065 40.13 40.13 42.42 0.74 300 1.88 1.88 1.82 1.91 2065 47.75 47.75 46.23 0.87 300 2.10 2.10 1.90 2.64 2065 53.34 53.34 48.26 1.20 300 1.41 1.34 1.66 1.43 2065 35.81 34.04 42.16 0.65 300 1.52 1.37 1.75 1.52 2065 38.61 34.80 44.45 0.69 300 1.65 1.50 1.80 1.78 2065 41.91 38.10 45.72 0.81 300 1.82 1.67 1.88 1.98 2065 46.23 42.42 47.75 0.90 1-1/2×1×1 CT53340×25×25 1-1/2×1×1-1/4 CT53440×25×32 1-1/2×1×1/2 CT53140×25×15 1-1/2×1×3/4 CT53240×25×20 1-1/4×1-1/4×1-1/2 CT44532×32×40 1-1/4×1-1/4×2 CT44632×32×50 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS 1×1/2×1 CT31325×15×25 1×3/4×1 CT32325×20×25 1×1×1/2 CT33125×25×15 1×1×3/4 CT33225×25×20 1×1×1-1/4 CT33425×25×32 1×1×1-1/2 CT33525×25×40 1-1/4×1×1/2 CT43132×25×15 1-1/4×1×3/4 CT43232×25×20 1-1/4×1×1 CT43332×25×25 1-1/4×1×1-1/4 CT43432×25×32 1-1/4×1×1-1/2 CT43532×25×40 1-1/4×1-1/4×1/2 CT44132×32×15 1-1/4×1-1/4×3/4 CT44232×32×20 1-1/4×1-1/4×1 CT44332×32×25 300 1.94 1.80 1.94 2.20 2065 49.28 45.72 49.28 1.00 300 1.41 1.34 1.66 1.58 2065 35.81 34.04 42.16 0.72 300 1.52 1.45 1.75 1.72 2065 38.61 36.83 44.45 0.78 300 1.65 1.58 1.80 1.91 2065 41.91 40.13 45.72 0.87 300 1.82 1.75 1.88 2.27 2065 46.23 44.45 47.75 1.03 A B C 300 1.94 1.88 1.94 2.42 2065 49.28 47.75 49.28 1.10 300 2.16 2.10 2.02 2.95 2065 54.86 53.34 51.31 1.34 300 1.41 1.41 1.66 1.80 2065 35.81 35.81 42.16 0.82 300 1.52 1.52 1.75 1.91 2065 38.61 38.61 44.45 0.87 300 1.65 1.65 1.80 2.09 2065 41.91 41.91 45.72 0.95 300 1.82 1.82 1.88 2.42 2065 46.23 46.23 47.75 1.10 300 2.16 2.16 2.02 2.99 2065 54.86 54.86 51.31 1.36 300 2.25 2.02 2.25 3.21 2065 57.15 51.31 57.15 1.46 300 2.25 2.10 2.25 3.50 2065 57.15 53.34 57.15 1.59 300 1.49 1.41 1.88 2.27 2065 37.85 35.81 47.75 1.03 300 1.60 1.52 1.97 2.38 2065 40.64 38.61 50.04 1.08 300 1.73 1.65 2.02 2.53 2065 43.94 41.91 51.31 1.15 300 1.90 1.82 2.10 2.86 2065 48.26 46.23 53.34 1.30 300 2.02 1.94 2.16 3.08 2065 51.31 49.28 54.86 1.40 300 2.25 2.16 2.25 3.59 2065 57.15 54.86 57.15 1.63 300 1.49 1.49 1.88 2.57 Pressure PSI/MPa Dimension Unit WT LB/KGS CT545 CT546 50×40×40 2×1-1/2×2 50×40×50 2×2×1/2 CT655 CT656 CT661 50×40×25 2×1-1/2×1-1/4 50×40×32 2×1-1/2×1-1/2 CT653 CT654 50×40×15 2×1-1/2×3/4 50×40×20 2×1-1/2×1 CT651 CT652 50×25×50 2×1-1/4×2 50×32×50 2×1-1/2×1/2 CT636 CT646 40×40×32 1-1/2×1-1/2×2 40×40×50 2×1×2 CT554 CT556 40×40×20 1-1/2×1-1/2×1 40×40×25 1-1/2×1-1/2×1-1/4 CT552 CT553 40×32×50 1-1/2×1-1/2×1/2 40×40×15 1-1/2×1-1/2×3/4 CT551 1-1/2×1-1/4×1-1/2 40×32×40 1-1/2×1-1/4×2 Nominal Size in/mm CODE 1-1/2×1-1/4×1-1/4 CT54440×32×32 1-1/2×1-1/4×3/4 CT54240×32×20 1-1/2×1-1/4×1 CT54340×32×25 1-1/2×1×1-1/2 CT53540×25×40 1-1/2×1-1/4×1/2 CT54140×32×15 10 CAST IRON A B C 300 1.50 1.36 1.50 1.06 2065 38.10 34.54 38.10 0.48 300 1.50 1.45 1.50 1.10 2065 38.10 36.83 38.10 0.50 300 1.26 1.26 1.36 0.97 2065 32.00 32.00 34.54 0.44 300 1.37 1.37 1.45 1.08 2065 34.80 34.80 36.83 0.49 300 1.67 1.67 1.58 1.45 2065 42.42 42.42 40.13 0.66 300 1.80 1.80 1.65 1.72 2065 45.72 45.72 41.91 0.78 300 1.34 1.26 1.53 1.19 2065 34.04 32.00 38.86 0.54 300 1.45 1.37 1.62 1.34 2065 36.83 34.80 41.15 0.61 300 1.58 1.50 1.67 1.45 2065 40.13 38.10 42.42 0.66 300 1.75 1.67 1.75 1.78 2065 44.45 42.42 44.45 0.81 300 1.88 1.80 1.82 1.94 2065 47.75 45.72 46.23 0.88 300 1.34 1.34 1.53 1.36 2065 34.04 34.04 38.86 0.62 300 1.45 1.45 1.62 1.41 2065 36.83 36.83 41.15 0.64 300 1.58 1.58 1.67 1.63 2065 40.13 40.13 42.42 0.74 300 1.88 1.88 1.82 1.91 2065 47.75 47.75 46.23 0.87 300 2.10 2.10 1.90 2.64 2065 53.34 53.34 48.26 1.20 300 1.41 1.34 1.66 1.43 2065 35.81 34.04 42.16 0.65 300 1.52 1.37 1.75 1.52 2065 38.61 34.80 44.45 0.69 300 1.65 1.50 1.80 1.78 2065 41.91 38.10 45.72 0.81 300 1.82 1.67 1.88 1.98 2065 46.23 42.42 47.75 0.90 1-1/2×1×1 CT53340×25×25 1-1/2×1×1-1/4 CT53440×25×32 1-1/2×1×1/2 CT53140×25×15 1-1/2×1×3/4 CT53240×25×20 1-1/4×1-1/4×1-1/2 CT44532×32×40 1-1/4×1-1/4×2 CT44632×32×50 Nominal Size in/mm CODE Pressure PSI/MPa Dimension Unit WT LB/KGS 1×1/2×1 CT31325×15×25 1×3/4×1 CT32325×20×25 1×1×1/2 CT33125×25×15 1×1×3/4 CT33225×25×20 1×1×1-1/4 CT33425×25×32 1×1×1-1/2 CT33525×25×40 1-1/4×1×1/2 CT43132×25×15 1-1/4×1×3/4 CT43232×25×20 1-1/4×1×1 CT43332×25×25 1-1/4×1×1-1/4 CT43432×25×32 1-1/4×1×1-1/2 CT43532×25×40 1-1/4×1-1/4×1/2 CT44132×32×15 1-1/4×1-1/4×3/4 CT44232×32×20 1-1/4×1-1/4×1 CT44332×32×25 300 1.94 1.80 1.94 2.20 2065 49.28 45.72 49.28 1.00 300 1.41 1.34 1.66 1.58 2065 35.81 34.04 42.16 0.72 300 1.52 1.45 1.75 1.72 2065 38.61 36.83 44.45 0.78 300 1.65 1.58 1.80 1.91 2065 41.91 40.13 45.72 0.87 300 1.82 1.75 1.88 2.27 2065 46.23 44.45 47.75 1.03 A B C 300 1.94 1.88 1.94 2.42 2065 49.28 47.75 49.28 1.10 300 2.16 2.10 2.02 2.95 2065 54.86 53.34 51.31 1.34 300 1.41 1.41 1.66 1.80 2065 35.81 35.81 42.16 0.82 300 1.52 1.52 1.75 1.91 2065 38.61 38.61 44.45 0.87 300 1.65 1.65 1.80 2.09 2065 41.91 41.91 45.72 0.95 300 1.82 1.82 1.88 2.42 2065 46.23 46.23 47.75 1.10 300 2.16 2.16 2.02 2.99 2065 54.86 54.86 51.31 1.36 300 2.25 2.02 2.25 3.21 2065 57.15 51.31 57.15 1.46 300 2.25 2.10 2.25 3.50 2065 57.15 53.34 57.15 1.59 300 1.49 1.41 1.88 2.27 2065 37.85 35.81 47.75 1.03 300 1.60 1.52 1.97 2.38 2065 40.64 38.61 50.04 1.08 300 1.73 1.65 2.02 2.53 2065 43.94 41.91 51.31 1.15 300 1.90 1.82 2.10 2.86 2065 48.26 46.23 53.34 1.30 300 2.02 1.94 2.16 3.08 2065 51.31 49.28 54.86 1.40 300 2.25 2.16 2.25 3.59 2065 57.15 54.86 57.15 1.63 300 1.49 1.49 1.88 2.57 Pressure PSI/MPa Dimension Unit WT LB/KGS CT545 CT546 50×40×40 2×1-1/2×2 50×40×50 2×2×1/2 CT655 CT656 CT661 50×40×25 2×1-1/2×1-1/4 50×40×32 2×1-1/2×1-1/2 CT653 CT654 50×40×15 2×1-1/2×3/4 50×40×20 2×1-1/2×1 CT651 CT652 50×25×50 2×1-1/4×2 50×32×50 2×1-1/2×1/2 CT636 CT646 40×40×32 1-1/2×1-1/2×2 40×40×50 2×1×2 CT554 CT556 40×40×20 1-1/2×1-1/2×1 40×40×25 1-1/2×1-1/2×1-1/4 CT552 CT553 40×32×50 1-1/2×1-1/2×1/2 40×40×15 1-1/2×1-1/2×3/4 CT551 1-1/2×1-1/4×1-1/2 40×32×40 1-1/2×1-1/4×2 Nominal Size in/mm CODE 1-1/2×1-1/4×1-1/4 CT54440×32×32 1-1/2×1-1/4×3/4 CT54240×32×20 1-1/2×1-1/4×1 CT54340×32×25 1-1/2×1×1-1/2 CT53540×25×40 1-1/2×1-1/4×1/2 CT54140×32×15 300 1.94 1.80 1.94 2.20 2065 49.28 45.72 49.28 1.00 300 1.41 1.34 1.66 1.58 2065 35.81 34.04 42.16 0.72 300 1.52 1.45 1.75 1.72 2065 38.61 36.83 44.45 0.78 300 1.65 1.58 1.80 1.91 2065 41.91 40.13 45.72 0.87 300 1.82 1.75 1.88 2.27 2065 46.23 44.45 47.75 1.03 A B C 300 1.94 1.88 1.94 2.42 2065 49.28 47.75 49.28 1.10 300 2.16 2.10 2.02 2.95 2065 54.86 53.34 51.31 1.34 300 1.41 1.41 1.66 1.80 2065 35.81 35.81 42.16 0.82 300 1.52 1.52 1.75 1.91 2065 38.61 38.61 44.45 0.87 300 1.65 1.65 1.80 2.09 2065 41.91 41.91 45.72 0.95 300 1.82 1.82 1.88 2.42 2065 46.23 46.23 47.75 1.10 300 2.16 2.16 2.02 2.99 2065 54.86 54.86 51.31 1.36 300 2.25 2.02 2.25 3.21 2065 57.15 51.31 57.15 1.46 300 2.25 2.10 2.25 3.50 2065 57.15 53.34 57.15 1.59 300 1.49 1.41 1.88 2.27 2065 37.85 35.81 47.75 1.03 300 1.60 1.52 1.97 2.38 2065 40.64 38.61 50.04 1.08 300 1.73 1.65 2.02 2.53 2065 43.94 41.91 51.31 1.15 300 1.90 1.82 2.10 2.86 2065 48.26 46.23 53.34 1.30 300 2.02 1.94 2.16 3.08 2065 51.31 49.28 54.86 1.40 300 2.25 2.16 2.25 3.59 2065 57.15 54.86 57.15 1.63 300 1.49 1.49 1.88 2.57 Pressure PSI/MPa Dimension Unit WT LB/KGS CT545 CT546 50×40×40 2×1-1/2×2 50×40×50 2×2×1/2 CT655 CT656 CT661 50×40×25 2×1-1/2×1-1/4 50×40×32 2×1-1/2×1-1/2 CT653 CT654 50×40×15 2×1-1/2×3/4 50×40×20 2×1-1/2×1 CT651 CT652 50×25×50 2×1-1/4×2 50×32×50 2×1-1/2×1/2 CT636 CT646 40×40×32 1-1/2×1-1/2×2 40×40×50 2×1×2 CT554 CT556 40×40×20 1-1/2×1-1/2×1 40×40×25 1-1/2×1-1/2×1-1/4 CT552 CT553 40×32×50 1-1/2×1-1/2×1/2 40×40×15 1-1/2×1-1/2×3/4 CT551 1-1/2×1-1/4×1-1/2 40×32×40 1-1/2×1-1/4×2 Nominal Size in/mm CODE 1-1/2×1-1/4×1-1/4 CT54440×32×32 1-1/2×1-1/4×3/4 CT54240×32×20 1-1/2×1-1/4×1 CT54340×32×25 1-1/2×1×1-1/2 CT53540×25×40 1-1/2×1-1/4×1/2 CT54140×32×15 2065 37.85 37.85 47.75 1.17 300 1.60 1.60 1.97 2.77 2065 40.64 40.64 50.04 1.26 300 1.73 1.73 2.02 2.93 2065 43.94 43.94 51.31 1.33 300 1.90 1.90 2.10 3.21 2065 48.26 48.26 53.34 1.46 300 2.02 2.02 2.16 3.52 2065 51.31 51.31 54.86 1.60 300 2.60 2.60 2.39 5.06 2065 66.04 66.04 60.71 2.30 2×2×2-1/2 CT66750×50×65 2×2×1-1/4 CT66450×50×32 2×2×1-1/2 CT66550×50×40 2×2×3/4 CT66250×50×20 2×2×1 CT66350×50×25 CT66150×50×15 300 1.94 1.80 1.94 2.20 2065 49.28 45.72 49.28 1.00 300 1.41 1.34 1.66 1.58 2065 35.81 34.04 42.16 0.72 300 1.52 1.45 1.75 1.72 2065 38.61 36.83 44.45 0.78 300 1.65 1.58 1.80 1.91 2065 41.91 40.13 45.72 0.87 300 1.82 1.75 1.88 2.27 2065 46.23 44.45 47.75 1.03 A B C 300 1.94 1.88 1.94 2.42 2065 49.28 47.75 49.28 1.10 300 2.16 2.10 2.02 2.95 2065 54.86 53.34 51.31 1.34 300 1.41 1.41 1.66 1.80 2065 35.81 35.81 42.16 0.82 300 1.52 1.52 1.75 1.91 2065 38.61 38.61 44.45 0.87 300 1.65 1.65 1.80 2.09 2065 41.91 41.91 45.72 0.95 300 1.82 1.82 1.88 2.42 2065 46.23 46.23 47.75 1.10 300 2.16 2.16 2.02 2.99 2065 54.86 54.86 51.31 1.36 300 2.25 2.02 2.25 3.21 2065 57.15 51.31 57.15 1.46 300 2.25 2.10 2.25 3.50 2065 57.15 53.34 57.15 1.59 300 1.49 1.41 1.88 2.27 2065 37.85 35.81 47.75 1.03 300 1.60 1.52 1.97 2.38 2065 40.64 38.61 50.04 1.08 300 1.73 1.65 2.02 2.53 2065 43.94 41.91 51.31 1.15 300 1.90 1.82 2.10 2.86 2065 48.26 46.23 53.34 1.30 300 2.02 1.94 2.16 3.08 2065 51.31 49.28 54.86 1.40 300 2.25 2.16 2.25 3.59 2065 57.15 54.86 57.15 1.63 300 1.49 1.49 1.88 2.57 Pressure PSI/MPa Dimension Unit WT LB/KGS CT545 CT546 50×40×40 2×1-1/2×2 50×40×50 2×2×1/2 CT655 CT656 CT661 50×40×25 2×1-1/2×1-1/4 50×40×32 2×1-1/2×1-1/2 CT653 CT654 50×40×15 2×1-1/2×3/4 50×40×20 2×1-1/2×1 CT651 CT652 50×25×50 2×1-1/4×2 50×32×50 2×1-1/2×1/2 CT636 CT646 40×40×32 1-1/2×1-1/2×2 40×40×50 2×1×2 CT554 CT556 40×40×20 1-1/2×1-1/2×1 40×40×25 1-1/2×1-1/2×1-1/4 CT552 CT553 40×32×50 1-1/2×1-1/2×1/2 40×40×15 1-1/2×1-1/2×3/4 CT551 1-1/2×1-1/4×1-1/2 40×32×40 1-1/2×1-1/4×2 Nominal Size in/mm CODE 1-1/2×1-1/4×1-1/4 CT54440×32×32 1-1/2×1-1/4×3/4 CT54240×32×20 1-1/2×1-1/4×1 CT54340×32×25 1-1/2×1×1-1/2 CT53540×25×40 1-1/2×1-1/4×1/2 CT54140×32×15 2065 37.85 37.85 47.75 1.17 300 1.60 1.60 1.97 2.77 2065 40.64 40.64 50.04 1.26 300 1.73 1.73 2.02 2.93 2065 43.94 43.94 51.31 1.33 300 1.90 1.90 2.10 3.21 2065 48.26 48.26 53.34 1.46 300 2.02 2.02 2.16 3.52 2065 51.31 51.31 54.86 1.60 300 2.60 2.60 2.39 5.06 2065 66.04 66.04 60.71 2.30 2×2×2-1/2 CT66750×50×65 2×2×1-1/4 CT66450×50×32 2×2×1-1/2 CT66550×50×40 2×2×3/4 CT66250×50×20 2×2×1 CT66350×50×25 CT66150×50×15 PLUG ▪Approved By UL, ULC and FM at 300 psi ▪Cast Iron ASTM A 126 Class B. ▪NPT Thread per ANSI/ASME B1.20.1. ▪Dimension per ASME B16.4 ▪Marked with SPD ▪For current listing/approval details contact a Titus representative 11 CAST IRON Dimension A 300 0.94 0.10 2065 23.88 0.05 300 1.07 0.18 2065 27.18 0.08 300 1.25 0.29 2065 31.75 0.13 300 1.36 0.46 2065 34.54 0.21 300 1.45 0.64 2065 36.83 0.29 300 1.56 1.08 2065 39.62 0.49 2 CPL00650 1-1/4 CPL00432 1-1/2 CPL00540 Pressure PSI/MPa Unit WT LB/KGS 1 CPL00325 1/2 CPL00115 3/4 CPL00220 Nominal Size in/mm CODE Dimension A 300 0.94 0.10 2065 23.88 0.05 300 1.07 0.18 2065 27.18 0.08 300 1.25 0.29 2065 31.75 0.13 300 1.36 0.46 2065 34.54 0.21 300 1.45 0.64 2065 36.83 0.29 300 1.56 1.08 2065 39.62 0.49 2 CPL00650 1-1/4 CPL00432 1-1/2 CPL00540 Pressure PSI/MPa Unit WT LB/KGS 1 CPL00325 1/2 CPL00115 3/4 CPL00220 Nominal Size in/mm CODE www.titusindustrial.com www.titusindustrial.com GROOVED TECHNICAL BULLETINS TABLE OF CONTENTS 2 TABLE OF CONTENTS GROOVED COUPLINGS 21LA LIGHT WEIGHT RIGID COUPLING . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 21LF LIGHT WEIGHT FLEXIBLE COUPLING . . . . . . . . . . . . . . . . . . . . . . . . . . 4 21RC REDUCING COUPLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 FLANGES & FLANGE ADAPTERS 31FH GROOVED HINGED FLANGE ADAPTER . . . . . . . . . . . . . . . . . . . . . . . 6 31FA GROOVED X FLANGE ADAPTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 GROOVED FITTINGS 31E 90° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 31F 45° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 31TT 22-1/2° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 31EL 11-1/4° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 31E+ SHORT PATTERN 90° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 31F+ SHORT PATTERN 45° ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 31T+ SHORT PATTERN TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 31T STRAIGHT TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 31X GROOVED CROSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 31RT GROOVED REDUCING TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 21RTS THREADED REDUCING TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 31X GROOVED REDUCING CROSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2601 DRAIN ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 31AE REDUCING END OF LINE ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 21CR GROOVED CONCENTRIC REDUCER . . . . . . . . . . . . . . . . . . . . . . . . 22 21MG THREADED CONCENTRIC REDUCER . . . . . . . . . . . . . . . . . . . . . . . 23 21C GROOVED END CAP; 31DC ECCENTRIC DRAIN CAP . . . . . . . . . . . . 24 MECHANICAL TEES 41 SADDLE-LET OUTLET TEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 31MT MECHANICAL TEE - THREADED . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 31MT MECHANICAL TEE - THREADED . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 31MG MECHANICAL TEE - GROOVED . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 31MG MECHANICAL TEE - GROOVED . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 LIGHT WEIGHT RIGID COUPLING ANGLE-PAD DESIGN ▪Maximum working pressure up to 300psi (34.5 bar). MWP varies based on coupling size and pipe schedule ▪Branded with TITUS or T ▪Gasket: Pre-Lubricated Grade E – EPDM with operating temperature of -30F to 230F (-34C to 110C) and is marked by a green stripe ▪Bolts are SAE J429 Grade 5 ▪All Groove dimensions conform to AWWA-C606 ▪All coupling housings conform to ASTM A-536 Grade 65-45-12 ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪Designed to meet metal to metal when properly installed ▪For current listing/approval details contact a Titus representative 21LA GROOVED COUPLINGS standard gaskets are designed to seal well ons up to 10 inHg (254 mmHg) which nuous greater than 10 inHg (254 mmHg), the use of on ) gaskets in rigid style couplings is recommended . Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applica ons. Reducing couplings are not recommended for these applica ons. di erent the sealing principles remain the same. The following are some of the most common gasket styles. Mechanical Tee Saddle-Let End Protection AWWA Ductile Iron Pipe IPS toAWWA HDPE Pipe Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applica ons. Reducing couplings are not recommended for these applica ons. di erent the sealing principles remain the same. The following are some of the most common gasket styles. Mechanical Tee Saddle-Let End Protection AWWA Ductile Iron Pipe IPS toAWWA HDPE Pipe GroovedCouplings • Maximum working pressure up to 300psi (34.5 bar). MWP varies based on coupling size and pipe schedule• randed with§P§­žȲ§ȲňūD­macua• Oval neck track bolts, tensile strength exceeds 110,000 psi and undergoesmagnetic particle inspection• Gasket: Pre-Lubricated Grade E – EPDM with operating temperature of -30Fto 230F (-34C to 110C) and is marked by a green stripe• All Groove dimensions conform to AWWA-C606• All coupling housings conform to ASTM A-536 Grade 65-45-12• Finish available in standard orange paint or hot dipped galvanized (ASTM A-153)• Designed to meet metal to metal when properly installed• For current listing/approval details contact a Titus representative LPFM§ W0PFM§ RPFP'Cu­”cPmF Angle-Pad Design GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products o ered and the variety of service applica ons , a wide variety of gaskets are available . Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn nuous services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda ons. FunkLok recommends the use of GapSeal Grade E gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo thegap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Wildcat C - Style GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products o ered and the variety of service applica ons , a wide variety of gaskets are available . Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn nuous services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda ons. FunkLok recommends the use of GapSeal Grade E gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo thegap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Wildcat Gap Seal WWW.TITUSINDUSTRIAL.COM ȝ * Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. * For a one time eld test, working pressure may be increased to 1.5 times the gures listed above. * For bolt torque recommendation see installation instructions or technical data sheets For dry pipe systems and freezer applications, petroleum free silicone lubricant is required and GapSeal gasket is recommended 21LA standard gaskets are designed to seal well ons up to 10 inHg (254 mmHg) which nuous greater than 10 inHg (254 mmHg), the use of on ) gaskets in rigid style couplings is recommended . Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applicaons. Reducing couplings are not recommended for these applica ons. dierent the sealing principles remain the same. The following are some of the most common gasket styles. Mechanical Tee Saddle-Let End Protection AWWA Ductile Iron Pipe IPS toAWWA HDPE Pipe Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applicaons. Reducing couplings are not recommended for these applica ons. dierent the sealing principles remain the same. The following are some of the most common gasket styles. Mechanical Tee Saddle-Let End Protection AWWA Ductile Iron Pipe IPS toAWWA HDPE Pipe GroovedCouplings • Maximum working pressure up to 300psi (34.5 bar). MWP varies based on coupling size and pipe schedule• randed with§P§­žȲ§ȲňūD­macua• Oval neck track bolts, tensile strength exceeds 110,000 psi and undergoesmagnetic particle inspection• Gasket: Pre-Lubricated Grade E – EPDM with operating temperature of -30Fto 230F (-34C to 110C) and is marked by a green stripe• All Groove dimensions conform to AWWA-C606• All coupling housings conform to ASTM A-536 Grade 65-45-12• Finish available in standard orange paint or hot dipped galvanized (ASTM A-153)• Designed to meet metal to metal when properly installed• For current listing/approval details contact a Titus representative LPFM§ W0PFM§ RPFP'Cu­”cPmF Angle-Pad Design GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products o ered and the variety of service applica ons , a wide variety of gaskets are available . Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn nuous services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda ons. FunkLok recommends the use of GapSeal Grade E gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo thegap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Wildcat C - Style GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products o ered and the variety of service applica ons , a wide variety of gaskets are available . Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn nuous services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda ons. FunkLok recommends the use of GapSeal Grade E gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo thegap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Wildcat Gap Seal WWW.TITUSINDUSTRIAL.COM ȝ * Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. * For a one time eld test, working pressure may be increased to 1.5 times the gures listed above. * For bolt torque recommendation see installation instructions or technical data sheets For dry pipe systems and freezer applications, petroleum free silicone lubricant is required and GapSeal gasket is recommended 21LA • Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. • For a one time field test, working pressure may be increased 1.5 times the figures listed above. • For bolt torque recommendtion, see installation instructions or technical data sheets. 25 32 40 50 65 65 80 100 125 125 150 150 150 200 250 300 350 400 33.7 42.4 48.3 60.3 73 76.1 88.9 114.3 139.7 141.3 159 165.1 168.3 219.1 273 323.9 355.6 406.4 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 1.80 2.92 3.79 5.91 8.66 9.41 12.84 21.22 31.70 32.43 41.06 44.27 46.00 77.97 121.05 170.39 198.53 259.30 0-1.6 0-1.6 0-1.6 0-1.6 0-1.6 0-1.6 0-1.6 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 0-4.1 56 64 69 88 100 100 116 142 170 170 196 197 199 262 325 376 410 459 96 106 113 122 137 137 154 188 219 219 244 244 246 322 400 468 500 550 47 47 47 47 47 47 47 52 52 52 52 52 52 66 66 67 75 75 M10×55 M10×60 M10×60 M10×60 M10×70 M10×70 M10×70 M12×75 M12×80 M12×80 M12×80 M12×80 M12×80 M16×120 M20×170 M22×190 M22×190 M22×190 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 5 5 6 6 6 8 10 12 14 16 1.327 1.669 1.9 2.375 2.875 3 3.5 4.5 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 14 16 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 405 656 852 1327 1945 2114 2885 4769 7124 7288 9229 9950 10340 17524 27206 38297 46150 60280 0-0.06 0-0.06 0-0.06 0-0.06 0-0.06 0-0.06 0-1.7 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 0-0.16 2.20 2.52 2.72 3.46 3.94 3.94 4.57 5.59 6.69 6.69 7.72 7.76 7.83 10.31 12.80 14.80 16.14 18.07 3.78 4.17 4.45 4.80 5.39 5.39 6.06 7.40 8.62 8.62 9.61 9.61 9.69 12.68 15.75 18.43 19.69 21.65 1.85 1.85 1.85 1.85 1.85 1.85 1.85 2.05 2.05 2.05 2.05 2.05 2.05 2.60 2.60 2.64 2.95 2.95 3/8×2-1/8 3/8×2-3/8 3/8×2-3/8 3/8×2-3/8 3/8×2-3/4 3/8×2-3/4 3/8×2-3/4 1/2×3 1/2×3-1/8 1/2×3-1/8 1/2×3-1/8 1/2×3-1/8 1/2×3-1/8 5/8×4-3/4 3/4×6-7/10 7/8×7-1/4 7/8×7-1/2 7/8×7-1/2 NominalSizein/mm Max.WorkingPressurePSI/Bar Max.EndLoadLbs/KN AxialDisplacementin/mm Ain/mm Bin/mm Cin/mm Dimensions Bolts Sizein/mmPipe O.D.in/mm C-Style gasket is approved for wet and dry fire protection applications to -40˚C. Petroleum free silicone lubricant is required in freezing applications. 3 ▪Maximum working pressure up to 300psi (34.5 bar). MWP varies based on coupling size and pipe schedule ▪Branded with TITUS or T ▪Gasket: Pre-Lubricated Grade E – EPDM with operating temperature of -30F to 230F (-34C to 110C) and is marked by a green stripe ▪Bolts are SAE J429 Grade 5 ▪All Groove dimensions conform to AWWA-C606 ▪All coupling housings conform to ASTM A-536 Grade 65-45-12 ▪Finish available in standard orange paint or hot dipped galvanized (ASTA-153) ▪For current listing/approval details contact a Titus representative 21LF GROOVED COUPLINGS LIGHT WEIGHT FLEXIBLE COUPLING • Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. • For a one time field test, working pressure may be increased 1.5 times the figures listed above. • For bolt torque recommendtion, see installation instructions or technical data sheets. 139.7 318.5 125 300 20 20 31.70 164.76 3.2 3.2 0.27 0.12 170 368 222 464 50 64 33.725 20 1.80 1.6 0.58 55 97 45 M10×40 1.3271 300 405 0.0625 48 2.17 3.82 1.77 3/8×1-1/2 42.432 20 2.92 1.6 0.46 63.5 107.5 45 M10×45 1.6691-1/4 300 656 0.0625 38 2.50 4.23 1.77 3/8×1-3/4 48.340 20 3.79 1.6 0.4 69 114 45 M10×45 1.91-1/2 300 852 0.0625 33 2.72 4.49 1.77 3/8×1-3/4 60.350 20 5.91 1.6 0.32 83.6 124 46 M10×55 2.3752 300 1327 0.0625 27 3.29 4.88 1.81 3/8×2-1/8 7365 20 8.66 1.6 0.26 98 137 46 M10×55 2.8752-1/2 300 1945 0.0625 22 3.86 5.39 1.81 3/8×2-1/8 76.165 20 9.41 1.6 0.25 98 139 46 M10×55 32-1/2 300 2114 0.0625 21 3.86 5.47 1.81 3/8×2-1/8 88.980 20 12.84 1.6 0.22 114 156 46 M10×55 3.53 300 2885 0.0625 18 4.49 6.14 1.81 3/8×2-1/8 108100 20 18.94 3.2 0.36 138 186 50 M12×65 4.254 300 4258 0.125 30 5.43 7.32 1.97 1/2×2-5/8 114.3100 20 21.22 3.2 0.34 142 189 50 M12×65 4.54 300 4769 0.125 28 5.59 7.44 1.97 1/2×2-5/8 133125 20 28.73 3.2 0.29 164 213 50 M12×65 5.255 300 6457 0.125 24 6.46 8.39 1.97 1/2×2-5/8 M12×65 5.55 300 7124 0.125 23 6.69 8.74 1.97 1/2×2-5/8 141.3125 20 32.43 3.2 0.27 170 218 50 M12×65 5.5635 300 7288 0.125 23 6.69 8.58 1.97 1/2×2-5/8 159150 20 41.06 3.2 0.24 192 244 50 M12×65 6.256 300 9229 0.125 20 7.56 9.61 1.97 1/2×2-5/8 165.1150 20 44.27 3.2 0.24 196 244 50 M12×65 6.56 300 9950 0.125 20 7.72 9.61 1.97 1/2×2-5/8 168.3150 20 46.00 3.2 0.23 198 251 50 M12×65 6.6256 300 10340 0.125 19 7.80 9.88 1.97 1/2×2-5/8 216.3200 20 75.99 3.2 0.18 254 340 62 M20×90 8.5158 300 17079 0.125 15 10.00 13.39 2.44 3/4×3-1/2 219.1200 20 77.97 3.2 0.18 256 316 60 M16×80 8.6258 300 17524 0.125 15 10.08 12.44 2.36 5/8×3-1/8 267.4250 20 116.13 3.2 0.14 313 400 64 M20×90 10.52710 300 26101 0.125 12 12.32 15.75 2.52 3/4×3-1/2 273.0 250 20 121.05 3.2 0.14 319 393 64 M20×90 10.7510 300 27206 0.125 12 12.56 15.47 2.52 3/4×3-1/2 M22×110 12.53912 300 37031 0.125 10 14.49 18.27 2.52 7/8×4-1/3 323.9300 20 170.39 3.2 0.12 374 453 65 M20×110 12.7512 300 38297 0.125 10 14.72 17.83 2.56 3/4×4-1/3 355.6350 20 198.53 3.2 0.06 410 510 75 M22×110 1414 300 46150 0.125 4.5 16.14 20.08 2.95 7/8×4-1/3 377350 20 230.84 3.2 0.06 428 520 75 M22×140 14.84314 300 51883 0.125 4.5 16.85 20.47 2.95 7/8×5-1/2 406.4400 20 259.30 3.2 0.05 459 555 75 M22×140 1616 300 60280 0.125 4 18.07 21.85 2.95 7/8×5-1/2 426400 20 294.74 3.2 0.05 480 572 75 M22×140 16.77116 300 66246 0.125 4 18.90 22.52 2.95 7/8×5-1/2 457.2 480.0 508.0 558.8 609.6 450 450 500 550 600 20 20 20 20 20 327.89 374.20 490.60 584.20 684.72 3.2 3.2 3.2 3.2 3.2 0.04 0.04 0.04 0.03 0.03 516 540 567 622 674 606 631 674 728 778 78 78 78 78 78 M22×140 M22×160 M22×140 M22×140 M24×150 18 18.9 20 22 24 18 18 20 22 24 300 300 300 300 300 76300 84106 113980 135640 159190 0.125 0.125 0.125 0.125 0.125 3.5 3 3 2.5 2.5 20.31 21.26 22.32 24.49 26.54 23.86 24.84 26.54 28.66 30.63 3.07 3.07 3.07 3.07 3.07 7/8×5-1/2 7/8×6-1/3 7/8×5-1/2 7/8×5-1/2 1×5-9/10 NominalSizein/mm Max.WorkingPressurePSI/Bar PerCouplingDegree(°) Per Pipe/in Max.EndLoadLbs/KN AxialDisplacementin/mm Ain/mm Bin/mm Cin/mm Sizein/mm Dimensions tloBtnemevoM ralugnAActualO.D.in/mm 2°-45´ 2°-10´ 1°-54´ 1°-31´ 1°-15´ 1°-12´ 1°-02´ 1°-42´ 1°-36´ 1°-23´ 1°-18´ 1°-18´ 1°-09´ 1°-07´ 1°-05´ 0°-50´ 0°-50´ 0°-50´ 0°-50´ 0°-50´ 0°-50´ 0°-31´ 0°-29' 0°-27´ 0°-25´ 0°-24´ 0°-22´ 0°-19´ 0°-18´ 0°-17´ Deflecon or angular movement is the maximum v alue that a coupling allows under no internal pressure. 4 * Deflection or angular movement is the maximim value that a coupling allows under no internal pressure. WWW.TITUSINDUSTRIAL.COM ȟ GroovedCouplings • Maximum working pressure up to 300psi (34.5 bar). MWP varies based oncoupling size and pipe schedule•randed withTITUSȲ§Ȳ or FUNKLOK• Oval neck track bolts, tensile strength exceeds 110,000 psi and undergoesmagnetic particle inspection• Gasket: Pre-Lubricated Grade E – EPDM with operating temperature of -30Fto 230F (-34C to 110C) and is marked by a green stripe• All Groove dimensions conform to AWWA-C606• All coupling housings conform to ASTM A-536 Grade 65-45-12• Finish available in standard orange paint or hot dipped galvanized (ASTA-153)• For current listing/approval details contact a Titus representative LPFM§ W0PFM§ Fc0ÈPc0 Cu­”cPmF GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products o the variety of service applica ons , a wide variety of gaskets are available . Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda FunkLok recommends the use of GapSeal gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Wildcat C - Style 33.7 1.327 42.4 1.669 48.3 1.9 60.3 2.375 73 2.875 76.1 3 88.9 3.5 108 4.25 114.3 4.5 133 5.25 139.7 5.5 141.3 5.563 159 6.25 165.1 6.5 168.3 6.625 216.3 8.515 219.1 8.625 267.4 10.527 273.0 10.75 318.5 12.539 323.9 12.75 355.6 14 377 14.843 406.4 16 426 16.771 457.2 18 480.0 18.9 508.0 20 558.8 22 609.6 24 25 1 32 11/4 40 11/2 50 2 65 21/2 65 21/2 80 3 100 4 100 4 125 5 125 5 125 5 150 6 150 6 150 6 200 8 200 8 250 10 250 10 300 12 300 12 350 14 350 14 400 16 400 16 450 18 450 18 500 20 550 22 600 24 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 1.80 405 2.92 656 3.79 852 5.91 1327 8.66 1945 9.41 2114 12.84 2885 18.94 4258 21.22 4769 28.73 6457 31.70 7124 32.43 7288 41.06 9229 44.27 9950 46.00 10340 75.99 17079 77.97 17524 116.13 26101 121.05 27206 164.76 37031 170.39 38297 198.53 46150 230.84 51883 259.30 60280 294.74 66246 327.89 76300 374.20 84106 490.60 113980 584.20 135640 684.72 159190 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 0.58 48 0.46 38 0.4 33 0.32 27 0.26 22 0.25 21 0.22 18 0.36 30 0.34 28 0.29 24 0.27 23 0.27 23 0.24 20 0.24 20 0.23 19 0.18 15 0.18 15 0.14 12 0.14 12 0.12 10 0.12 10 0.06 4.5 0.06 4.5 0.05 4 0.05 4 0.04 3.5 0.04 3 0.04 3 0.03 2.5 0.03 2.5 55 2.17 63.5 2.50 69 2.72 83.6 3.29 98 3.86 98 3.86 114 4.49 138 5.43 142 5.59 164 6.46 170 6.69 170 6.69 192 7.56 196 7.72 198 7.80 254 10.00 256 10.08 313 12.32 319 12.56 368 14.49 374 14.72 410 16.14 428 16.85 459 18.07 480 18.90 516 20.31 540 21.26 567 22.32 622 24.49 674 26.54 97 3.82 107.5 4.23 114 4.49 124 4.88 137 5.39 139 5.47 156 6.14 186 7.32 189 7.44 213 8.39 222 8.74 218 8.58 244 9.61 244 9.61 251 9.88 340 13.39 316 12.44 400 15.75 393 15.47 464 18.27 453 17.83 510 20.08 520 20.47 555 21.85 572 22.52 606 23.86 631 24.84 674 26.54 728 28.66 778 30.63 45 1.77 45 1.77 45 1.77 46 1.81 46 1.81 46 1.81 46 1.81 50 1.97 50 1.97 50 1.97 50 1.97 50 1.97 50 1.97 50 1.97 50 1.97 62 2.44 60 2.36 64 2.52 64 2.52 64 2.52 65 2.56 75 2.95 75 2.95 75 2.95 75 2.95 78 3.07 78 3.07 78 3.07 78 3.07 78 3.07 M10×40 3/8×1-1/2 M10×45 3/8×1-3/4 M10×45 3/8×1-3/4 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M20×90 3/4×3-1/2 M16×80 5/8×3-1/8 M20×90 3/4×3-1/2 M20×90 3/4×3-1/2 M22×110 7/8×4-1/3 M20×110 3/4×4-1/3 M22×110 7/8×4-1/3 M22×140 7/8×5-1/2 M22×140 7/8×5-1/2 M22×140 7/8×5-1/2 M22×140 7/8×5-1/2 M22×160 7/8×6-1/3 M22×140 7/8×5-1/2 M22×140 7/8×5-1/2 M24×150 1×5-9/10 NominalSizemm/in Max.WorkingPressureBar/PSI PerCouplingDegree(°) Per Pipein/ Max.EndLoadKN/Lbs AxialDisplacementmm/in Amm/in Bmm/in Cmm/in Sizemm/in DimensionsAngular Movement Bolt ActualO.D.mm/in 2°-45´ 2°-10´ 1°-54´ 1°-31´ 1°-15´ 1°-12´ 1°-02´ 1°-42´ 1°-36´ 1°-23´ 1°-18´ 1°-18´ 1°-09´ 1°-07´ 1°-05´ 0°-50´ 0°-50´ 0°-50´ 0°-50´ 0°-50´ 0°-50´ 0°-31´ 0°-29' 0°-27´ 0°-25´ 0°-24´ 0°-22´ 0°-19´ 0°-18´ 0°-17´ * Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. * For a one time eld test, working pressure may be increased to 1.5 times the gures listed above. * For bolt torque recommendation see installation instructions or technical data sheets For dry pipe systems and freezer applications, petroleum free silicone lubricant is required and GapSeal gasket is recommended. 21LF C-Style gasket is approved for wet and dry fire protection applications to -40˚C. Petroleum free silicone lubricant is required in freezing applications. C REDUCING COUPLING ▪Maximum working pressure up to 300psi (34.5 bar). MWP varies based on coupling size and pipe schedule ▪Branded with TITUS or T ▪All Groove dimensions conform to AWWA-C606 ▪All coupling housings conform to ASTM A-536 Grade 65-45-12 ▪Finish available in standard orange paint or hot dipped galvanized (ASTA-153) ▪The steel washer (optional) prevents telescoping of the smaller pipe inside larger pipe. Only recommended during vertical system assembly. ▪For current listing/approval details contact a Titus representative 21RC GROOVED COUPLINGS • Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. • For a one time field test, working pressure may be increased 1.5 times the figures listed above. • For bolt torque recommendation, see installation instructions or technical data sheets. 5 * Deflection or angular movement is the maximim value that a coupling allows under no internal pressure. ** Dimension C is axial thickness of coupling. WWW.TITUSINDUSTRIAL.COM GroovedCouplings • Maximum working pressure up to 300psi (34.5 bar). MWP varies based oncoupling size and pipe schedule•randed with§P§­žRU§• Oval neck track bolts, tensile strength exceeds 110,000 psi and undergoes magnetic particle inspection• All Groove dimensions conform to AWWA-C606• All coupling housings conform to ASTM A-536 Grade 65-45-12• Finish available in standard orange paint or hot dipped galvanized (ASTA-153)• For current listing/approval details contact a Titus representative REDUCING COUPLING For dry pipe systems and freezer applications, petroleum free silicone lubricant is required and GapSeal gasket is recommended * Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. * For a one time eld test, working pressure may be increased to 1.5 times the gures listed above. * For bolt torque recommendation see installation instructions or technical data sheets 48.3×42.4 1.9×1.669 60.3×48.3 2.375×1.9 73×33.7 2.875×1.327 73×42.4 2.875×1.669 73×48.3 2.875×1.9 73×60.3 2.875×2.375 76.1×60.3 3×2.375 76.1×73 3×2.875 88.9×48.3 3.5×1.9 88.9×60.3 3.5×2.375 88.9×73.0 3.5×2.875 88.9×76.1 3.5×3 114.3×60.3 4.5×2.375 114.3×73.0 4.5×2.875 114.3×76.1 4.5×3.0 114.3×88.9 4.5×3.5 139.7×114.3 5.5×4.5 141.3×114.3 5.563×4.5 165.1×88.9 6.5×3.5 165.1×114.3 6.5×4.5 168.3×73 6.525×2.875 168.3×88.9 6.525×3.5 168.3×114.3 6.525×4.5 168.3×141.3 6.625×5.563 168.3×165.1 6.625×6.5 219.1×114.3 8.625×4.5 219.1×168.3 8.625×6.525 40×32 11/2×11/4 50×40 2x11/2 65×25 21/2x1 65×32 21/2x11/4 65×40 21/2x11/2 65×50 21/2x2 65×50 21/2x2 65×65 21/2x21/2 80×40 3x11/2 80×50 3×2 80×65 3x21/2 80×65 3x21/2 100×50 4×2 100×65 4x21/2 100×65 4x21/2 100×80 4×3 125×100 5×4 125×100 5×4 150×80 6×3 150×100 6×4 150×65 6×21/2 150×80 6×3 150×100 6×4 150×100 6×5 150×150 6×6 200×100 8×4 200×150 8×6 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 3.79 852 5.91 1327 8.66 1945 8.66 1945 8.66 1945 8.66 1945 9.41 2114 9.41 2114 12.84 2885 12.84 2885 12.84 2885 12.84 2885 21.22 4769 21.22 4769 21.22 4769 21.22 4769 31.70 7124 32.43 7288 44.27 9950 44.27 9950 46.00 10340 46.00 10340 46.00 10340 46.00 10340 46.00 10340 77.97 17524 77.97 17524 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 0.4 33 0.32 27 0.26 22 0.26 22 0.26 22 0.26 22 0.25 21 0.25 21 0.22 18 0.22 18 0.22 18 0.22 18 0.34 28 0.34 28 0.34 28 0.34 28 0.27 23 0.27 23 0.24 20 0.24 20 0.23 19 0.23 19 0.23 19 0.23 19 0.23 19 0.18 15 0.18 15 70 2.76 82 3.23 97 3.82 97 3.82 97 3.82 97 3.82 97 3.82 97 3.82 112 4.41 112 4.41 112 4.41 114 4.49 141 5.55 141 5.55 151.2 5.95 141.8 5.58 169 6.65 167 6.57 197 7.76 197 7.76 199.4 7.85 199.4 7.85 199.4 7.85 199.4 7.85 199.4 7.85 256 10.08 256 10.08 113 4.45 130 5.12 151 5.94 151 5.94 151 5.94 151 5.94 151 5.94 151 5.94 166.6 6.56 166.6 6.56 166.6 6.56 166.6 6.56 200 7.87 200 7.87 200 7.87 200 7.87 235 9.25 230 9.06 275 10.83 275 10.83 275 10.83 275 10.83 275 10.83 275 10.83 275 10.83 336 13.23 336 13.23 45 1.77 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 50 1.97 50 1.97 50 1.97 50 1.97 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 58 2.28 58 2.28 M10×50 3/8×2 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M20×110 3/4×4-1/3 M20×110 3/4×4-1/3 NominalSizemm/in Max. WorkingPressureBar/PSI Degree PerCoupling(°)Pipemm/m in/ Max.EndLoadKN/Lbs AxialDisplacementmm/in Amm/in Bmm/in Cmm/in Bolt Sizemm/in DimensionsDeeconActualO.D.mm/in 1°-54´ 1°-31´ 1°-15´ 1°-15´ 1°-15´ 1°-15´ 1°-12´ 1°-12´ 1°-02´ 1°-02´ 1°-02´ 1°-02´ 1°-36´ 1°-36´ 1°-36´ 1°-36´ 1°-18´ 1°-18´ 1°-07´ 1°-07´ 1°-06´ 1°-06´ 1°-06´ 1°-06´ 1°-06´ 0°-50´ 0°-50´ VACUUM SERVICE DRY PIPE AND FREEZER SERVICES FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn nuous services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda ons. Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applica ons. Reducing couplings are not recommended for these applica FunkLok recommends the use of GapSeal Grade E gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo thegap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Reducing Outlet Coupling Flange GapSeal Gasket Saddle-Let End ProtectionWildcat GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products oīered and the variety of service applicaƟons , a wide variety of gaskets are available .Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condiƟons up to 10 inHg (254 mmHg) which may occur when a system is drained .For connƟnuous services greater than 10 inHg (254 mmHg), the use of 'ĂƉ^ĞĂů gaskets or EP (end protecƟon ) gaskets in combinaƟon with rigid style couplings is recommended . Contact FunkLok f or speciĮc recommendaƟons. Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applicaƟons. Reducing couplings are not recommended for these applicaƟons. FunkLok recommends the use of 'ĂƉ^ĞĂů Grade E gaskets for dry pipe Įre protecƟon systems and freezer applicaƟons. The 'ĂƉ^ĞĂů gasket close oī the gap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the caviƟes and freezing when the temperature drops. diīerent the sealing principles remain the same. The following are some of the most common gasket styles.GASKET SELECTION GUIDE Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Mechanical Tee Saddle-Let End ProtectionWildcat AWWA Ductile Iron Pipe IPS to AWWA HDPE Pipe b-'91+:9+2+):/54-;/*+ Reducing 21RC WWW.TITUSINDUSTRIAL.COM GroovedCouplings • Maximum working pressure up to 300psi (34.5 bar). MWP varies based oncoupling size and pipe schedule•randed with§P§­žRU§• Oval neck track bolts, tensile strength exceeds 110,000 psi and undergoes magnetic particle inspection• All Groove dimensions conform to AWWA-C606• All coupling housings conform to ASTM A-536 Grade 65-45-12• Finish available in standard orange paint or hot dipped galvanized (ASTA-153)• For current listing/approval details contact a Titus representative REDUCING COUPLING For dry pipe systems and freezer applications, petroleum free silicone lubricant is required and GapSeal gasket is recommended * Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. * For a one time eld test, working pressure may be increased to 1.5 times the gures listed above. * For bolt torque recommendation see installation instructions or technical data sheets 48.3×42.4 1.9×1.669 60.3×48.3 2.375×1.9 73×33.7 2.875×1.327 73×42.4 2.875×1.669 73×48.3 2.875×1.9 73×60.3 2.875×2.375 76.1×60.3 3×2.375 76.1×73 3×2.875 88.9×48.3 3.5×1.9 88.9×60.3 3.5×2.375 88.9×73.0 3.5×2.875 88.9×76.1 3.5×3 114.3×60.3 4.5×2.375 114.3×73.0 4.5×2.875 114.3×76.1 4.5×3.0 114.3×88.9 4.5×3.5 139.7×114.3 5.5×4.5 141.3×114.3 5.563×4.5 165.1×88.9 6.5×3.5 165.1×114.3 6.5×4.5 168.3×73 6.525×2.875 168.3×88.9 6.525×3.5 168.3×114.3 6.525×4.5 168.3×141.3 6.625×5.563 168.3×165.1 6.625×6.5 219.1×114.3 8.625×4.5 219.1×168.3 8.625×6.525 40×32 11/2×11/4 50×40 2x11/2 65×25 21/2x1 65×32 21/2x11/4 65×40 21/2x11/2 65×50 21/2x2 65×50 21/2x2 65×65 21/2x21/2 80×40 3x11/2 80×50 3×2 80×65 3x21/2 80×65 3x21/2 100×50 4×2 100×65 4x21/2 100×65 4x21/2 100×80 4×3 125×100 5×4 125×100 5×4 150×80 6×3 150×100 6×4 150×65 6×21/2 150×80 6×3 150×100 6×4 150×100 6×5 150×150 6×6 200×100 8×4 200×150 8×6 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 20 300 3.79 852 5.91 1327 8.66 1945 8.66 1945 8.66 1945 8.66 1945 9.41 2114 9.41 2114 12.84 2885 12.84 2885 12.84 2885 12.84 2885 21.22 4769 21.22 4769 21.22 4769 21.22 4769 31.70 7124 32.43 7288 44.27 9950 44.27 9950 46.00 10340 46.00 10340 46.00 10340 46.00 10340 46.00 10340 77.97 17524 77.97 17524 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 1.6 0.0625 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 3.2 0.125 0.4 33 0.32 27 0.26 22 0.26 22 0.26 22 0.26 22 0.25 21 0.25 21 0.22 18 0.22 18 0.22 18 0.22 18 0.34 28 0.34 28 0.34 28 0.34 28 0.27 23 0.27 23 0.24 20 0.24 20 0.23 19 0.23 19 0.23 19 0.23 19 0.23 19 0.18 15 0.18 15 70 2.76 82 3.23 97 3.82 97 3.82 97 3.82 97 3.82 97 3.82 97 3.82 112 4.41 112 4.41 112 4.41 114 4.49 141 5.55 141 5.55 151.2 5.95 141.8 5.58 169 6.65 167 6.57 197 7.76 197 7.76 199.4 7.85 199.4 7.85 199.4 7.85 199.4 7.85 199.4 7.85 256 10.08 256 10.08 113 4.45 130 5.12 151 5.94 151 5.94 151 5.94 151 5.94 151 5.94 151 5.94 166.6 6.56 166.6 6.56 166.6 6.56 166.6 6.56 200 7.87 200 7.87 200 7.87 200 7.87 235 9.25 230 9.06 275 10.83 275 10.83 275 10.83 275 10.83 275 10.83 275 10.83 275 10.83 336 13.23 336 13.23 45 1.77 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 46 1.81 50 1.97 50 1.97 50 1.97 50 1.97 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 52 2.05 58 2.28 58 2.28 M10×50 3/8×2 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M10×55 3/8×2-1/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M12×65 1/2×2-5/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M16×80 5/8×3-1/8 M20×110 3/4×4-1/3 M20×110 3/4×4-1/3 NominalSizemm/in Max. WorkingPressureBar/PSI Degree PerCoupling(°)Pipemm/m in/ Max.EndLoadKN/Lbs AxialDisplacementmm/in Amm/in Bmm/in Cmm/in Bolt Sizemm/in DimensionsDeeconActualO.D.mm/in 1°-54´ 1°-31´ 1°-15´ 1°-15´ 1°-15´ 1°-15´ 1°-12´ 1°-12´ 1°-02´ 1°-02´ 1°-02´ 1°-02´ 1°-36´ 1°-36´ 1°-36´ 1°-36´ 1°-18´ 1°-18´ 1°-07´ 1°-07´ 1°-06´ 1°-06´ 1°-06´ 1°-06´ 1°-06´ 0°-50´ 0°-50´ VACUUM SERVICE DRY PIPE AND FREEZER SERVICES FunkLok standard gaskets are designed to seal well under vacuum condi ons up to 10 inHg (254 mmHg) which may occur when a system is drained . For conn nuous services greater than 10 inHg (254 mmHg), the use of GapSeal gaskets or EP (end protec on ) gaskets in combina on with rigid style couplings is recommended . Contact FunkLok for speci c recommenda ons. Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applica ons. Reducing couplings are not recommended for these applica FunkLok recommends the use of GapSeal Grade E gaskets for dry pipe re protec on systems and freezer applica ons.The GapSeal gasketcloseo thegap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the cavi es and freezing when the temperature drops. Reducing Outlet Coupling Flange GapSeal Gasket Saddle-Let End ProtectionWildcat GASKET STYLES VACUUM SERVICE DRY PIPE AND FREEZER SERVICES Due to the number of FunkLok products oīered and the variety of service applicaƟons , a wide variety of gaskets are available .Even though the products and gaskets may look FunkLok standard gaskets are designed to seal well under vacuum condiƟons up to 10 inHg (254 mmHg) which may occur when a system is drained .For connƟnuous services greater than 10 inHg (254 mmHg), the use of 'ĂƉ^ĞĂů gaskets or EP (end protecƟon ) gaskets in combinaƟon with rigid style couplings is recommended . Contact FunkLok f or speciĮc recommendaƟons. Do not use the normal lubricant for dry pipe and freezer systems. Always use a petroleum free silicone based lubricant. Rigid couplings are preferred for dry pipe, freezer and vacuum applicaƟons. Reducing couplings are not recommended for these applicaƟons. FunkLok recommends the use of 'ĂƉ^ĞĂů Grade E gaskets for dry pipe Įre protecƟon systems and freezer applicaƟons. The 'ĂƉ^ĞĂů gasket close oī the gap between the pipes or gasket cavity. This will prevent any remaining liquid from entering the caviƟes and freezing when the temperature drops. diīerent the sealing principles remain the same. The following are some of the most common gasket styles.GASKET SELECTION GUIDE Standard Reducing GapSeal Outlet Coupling Flange GapSeal Gasket Mechanical Tee Saddle-Let End ProtectionWildcat AWWA Ductile Iron Pipe IPS to AWWA HDPE Pipe b-'91+:9+2+):/54-;/*+ Reducing 21RC 48.3×42.4 60.3×48.3 73×33.7 73×42.4 73×48.3 73×60.3 76.1×60.3 76.1×73 88.9×48.3 88.9×60.3 88.9×73.0 88.9×76.1 114.3×60.3 114.3×73.0 114.3×76.1 114.3×88.9 139.7×114.3 141.3×114.3 165.1×88.9 165.1×114.3 168.3×73 168.3×88.9 168.3×114.3 168.3×141.3 168.3×165.1 219.1×114.3 219.1×168.3 40×32 50×40 65×25 65×32 65×40 65×50 65×50 65×65 80×40 80×50 80×65 80×65 100×50 100×65 100×65 100×80 125×100 125×100 150×80 150×100 150×65 150×80 150×100 150×100 150×150 200×100 200×150 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 3.79 5.91 8.66 8.66 8.66 8.66 9.41 9.41 12.84 12.84 12.84 12.84 21.22 21.22 21.22 21.22 31.70 32.43 44.27 44.27 46.00 46.00 46.00 46.00 46.00 77.97 77.97 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 0.4 0.32 0.26 0.26 0.26 0.26 0.25 0.25 0.22 0.22 0.22 0.22 0.34 0.34 0.34 0.34 0.27 0.27 0.24 0.24 0.23 0.23 0.23 0.23 0.23 0.18 0.18 70 82 97 97 97 97 97 97 112 112 112 114 141 141 151.2 141.8 169 167 197 197 199.4 199.4 199.4 199.4 199.4 256 256 113 130 151 151 151 151 151 151 166.6 166.6 166.6 166.6 200 200 200 200 235 230 275 275 275 275 275 275 275 336 336 45 46 46 46 46 46 46 46 46 46 46 46 50 50 50 50 52 52 52 52 52 52 52 52 52 58 58 M10×50 M10×55 M10×55 M10×55 M10×55 M10×55 M10×55 M10×55 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M16×80 M16×80 M16×80 M16×80 M16×80 M16×80 M16×80 M16×80 M16×80 M20×110 M20×110 1.9×1.669 2.375×1.9 2.875×1.327 2.875×1.669 2.875×1.9 2.875×2.375 3×2.375 3×2.875 3.5×1.9 3.5×2.375 3.5×2.875 3.5×3 4.5×2.375 4.5×2.875 4.5×3.0 4.5×3.5 5.5×4.5 5.563×4.5 6.5×3.5 6.5×4.5 6.525×2.875 6.525×3.5 6.525×4.5 6.625×5.563 6.625×6.5 8.625×4.5 8.625×6.525 1-1/2×1-1/4 2x1-1/2 2-1/2x1 2-1/2x1-1/4 2-1/2x1-1/2 2-1/2x2 2-1/2x2 2-1/2x2-1/2 3x1-1/2 3×2 3x2-1/2 3x2-1/2 4×2 4x2-1/2 4x2-1/2 4×3 5×4 5×4 6×3 6×4 6×2-1/2 6×3 6×4 6×5 6×6 8×4 8×6 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 852 1327 1945 1945 1945 1945 2114 2114 2885 2885 2885 2885 4769 4769 4769 4769 7124 7288 9950 9950 10340 10340 10340 10340 10340 17524 17524 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.0625 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 33 27 22 22 22 22 21 21 18 18 18 18 28 28 28 28 23 23 20 20 19 19 19 19 19 15 15 2.76 3.23 3.82 3.82 3.82 3.82 3.82 3.82 4.41 4.41 4.41 4.49 5.55 5.55 5.95 5.58 6.65 6.57 7.76 7.76 7.85 7.85 7.85 7.85 7.85 10.08 10.08 4.45 5.12 5.94 5.94 5.94 5.94 5.94 5.94 6.56 6.56 6.56 6.56 7.87 7.87 7.87 7.87 9.25 9.06 10.83 10.83 10.83 10.83 10.83 10.83 10.83 13.23 13.23 1.77 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.97 1.97 1.97 1.97 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.28 3/8×2 3/8×2-1/8 3/8×2-1/8 3/8×2-1/8 3/8×2-1/8 3/8×2-1/8 3/8×2-1/8 3/8×2-1/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 5/8×3-1/8 3/4×4-1/3 3/4×4-1/3 NominalSizein/mm Max. WorkingPressurePSI/Bar Degree PerCoupling(°)Pipein/ mm/m Max.EndLoadLbs/KN AxialDisplacementin/mm Ain/mm Bin/mm Cin/mm Bolt Sizein/mm DimensionsDefleconActualO.D.in/mm 1°-54´ 1°-31´ 1°-15´ 1°-15´ 1°-15´ 1°-15´ 1°-12´ 1°-12´ 1°-02´ 1°-02´ 1°-02´ 1°-02´ 1°-36´ 1°-36´ 1°-36´ 1°-36´ 1°-18´ 1°-18´ 1°-07´ 1°-07´ 1°-06´ 1°-06´ 1°-06´ 1°-06´ 1°-06´ 0°-50´ 0°-50´ Deflec on or angular movement is the maximum value that a coupling allows under no internal pressure. * ** GROOVED HINGED FLANGE ADAPTER ▪Maximum working pressure 250 psi (17 bar) depending on flange size and schedule of pipe ▪Matches flange dimensions of Class 125/150, latch bolts included ▪Branded with TITUS or T ▪Gasket: Grade E – EPDM with operating temperature of -30F to 230F (-34C to 110C) and is marked by a green stripe ▪Bolts are SAE J429 Grade 5 ▪All Groove dimensions conform to AWWA-C606 ▪All Ductile Iron housing materials conform to ASTM A-536 Grade 65-45-12 ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪Steel adapter insert required when used against wafer/lug valves, with rubber or irregular surfaces ▪For current listing/approval details contact a Titus representative 31FH FLANGE ADAPTERS 50 65 80 100 125 150 200 250 300 60.3 73.0 88.9 114.3 141.3 168.3 219.1 273.0 323.9 20 20 20 20 20 20 20 20 20 5.71 8.37 12.41 20.51 31.35 44.47 75.37 164.71 164.71 155 180 190 230 255 280 345 405 485 120.5 140 153 191 216 241 299 362 432 25 25 25 25 25 25 27 30 32 60 73 89 114 141 168 219 273 324 78 93 107 131 157 185 234 294 341 M16 M16 M16 M16 M20 M20 M20 M24 M24 2 2.5 3 4 5 6 8 10 12 2.375 2.875 3.500 4.500 5.563 6.625 8.625 10.750 12.75 300 300 300 300 300 300 300 300 300 1330 1950 2880 4770 7290 10340 17520 27210 38280 6.10 7.09 7.48 9.06 10.04 11.02 13.58 15.94 19.09 4.74 5.51 6.02 7.52 8.50 9.49 11.77 14.25 17.01 0.98 0.98 0.98 0.98 0.98 0.98 1.06 1.18 1.26 2.36 2.87 3.50 4.49 5.55 6.61 8.62 10.75 12.76 3.07 3.66 4.21 5.16 6.18 7.28 9.21 11.57 13.43 5/8 5/8 5/8 5/8 3/4 3/4 3/4 1 1 4 4 4 8 8 8 8 12 12 NominalSizein/mm Max.WorkingPressurePSI/Bar Max. EndLoadLbs/KN Ain/mm Bin/mm Cin/mm Din/mm Ein/mm Sizein/mmNo. BoltDimensionsPipe O.D.in/mm • Working pressure and/or end load are based on schedule 7/10/40 steel pipe, cut or roll grooved. • For a one time field test, working pressure may be increased 1.5 times the figures listed above. • For bolt torque recommendtion, see installation instructions or technical data sheets. 6 GROOVED X FLANGE ADAPTER ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31FA FLANGE ADAPTERS 50 65 80 100 125 150 200 250 300 60.3 73.00 88.90 114.30 141.3 168.30 219.1 273 323.9 4 4 4 8 8 8 8 12 12 NominalSizein/mm Xin/mm Yin/mm Zin/mm Lin/mm Bolts No.Pipe O.D.in /mm 20 20 20 20 20 20 20 20 20 155 180 190 230 255 280 345 405 485 120.5 140 153 191 216 241 299 362 432 16 16 18 22 22 22 25 26 28 65 65 65 70 70 70 80 85 90 M16 M16 M16 M16 M20 M20 M20 M22 M22 2 2-1/2 3 4 5 6 8 10 12 2.375 2.875 3.50 4.50 5.563 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 6.10 7.09 7.48 9.06 10.04 11.02 13.58 15.94 19.09 4.74 5.51 6.02 7.52 8.50 9.49 11.77 14.25 17.01 0.63 0.63 0.71 0.87 0.87 0.87 0.98 1.02 1.10 2.56 2.56 2.56 2.76 2.76 2.76 3.15 3.35 3.54 5/8 5/8 5/8 5/8 3/4 3/4 3/4 7/8 7/8 Max.WorkingPressurePSI/Bar Bolts Sizein/mm 7 A A Z XY L SECTION A-ASCALE 1 : 1 A A B B 4 4 3 3 2 2 1 1 A A Z XY L SECTION A-ASCALE 1 : 1 A A B B 4 4 3 3 2 2 1 1 90° ELBOW ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31E GROOVED FITTINGS 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 133 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 111 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 54 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 5.25 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.37 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.13 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 in/mm 8 ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 45° ELBOW31F GROOVED FITTINGS 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 in/mmin/mm in/mm in/mm 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 in/mmin/mm in/mm in/mm 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 9 ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 22-1/2° ELBOW31TT GROOVED FITTINGS 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 in/mmin/mm in/mm in/mm 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 in/mmin/mm in/mm in/mm 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 10 ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 11-1/4° ELBOW31EL GROOVED FITTINGS 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 in/mmin/mm in/mm in/mm 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 57 70 70 83 95 95 108 127 127 140 140 140 165 165 165 197 229 254 45 45 45 51 62 62 70 76 76 83 83 83 89 89 89 108 121 45 45 45 48 51 51 57 73 73 73 73 73 79 79 79 98 124 35 35 35 38 38 38 38 45 45 51 51 51 51 51 51 51 57 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm 90° Elbow Standard C- E 45° Elbow Standard C- E 22-1/2° Elbow C- E 11-1/4° Elbow C- E Max.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 in/mmin/mm in/mm in/mm 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.24 2.76 2.76 3.27 3.74 3.74 4.25 5 5 5.51 5.51 5.51 6.5 6.5 6.5 7.76 9.02 10 1.77 1.77 1.77 2.01 2.44 2.44 2.76 2.99 2.99 3.27 3.27 3.27 3.50 3.50 3.50 4.25 4.76 1.77 1.77 1.77 1.89 2.01 2.01 2.24 2.87 2.87 2.87 2.87 2.87 3.11 3.11 3.11 3.86 4.88 1.38 1.38 1.38 1.50 1.50 1.50 1.50 1.77 1.77 2.01 2.01 2.01 2.01 2.01 2.01 2.01 2.24 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 11 SHORT PATTERN 90° ELBOW ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31E+ GROOVED FITTINGS 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 48 48 53 60 60 68 68 68 75.5 75.5 75.5 95 112 135 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm SR 90° Elbow C- E (in/mm)C- E (in/mm)C- E (in/mm) 45° Elbow SR Straight Te eMax.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 1.89 1.89 2.09 2.36 2.36 2.68 2.68 2.68 2.97 2.97 2.97 3.74 4.41 5.31 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 12 Pr e s s u r e D r o p (f t o f s c h e d u l e 4 0 p i p e ) Flow Rate (ft./sec.) SHORT PATTERN 90° ELBOW PRESSURE DROP ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative SHORT PATTERN 45° ELBOW31F+ 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 48 48 53 60 60 68 68 68 75.5 75.5 75.5 95 112 135 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm SR 90° Elbow C- E (in/mm)C- E (in/mm)C- E (in/mm) 45° Elbow SR Straight Te eMax.Wo rkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 1.89 1.89 2.09 2.36 2.36 2.68 2.68 2.68 2.97 2.97 2.97 3.74 4.41 5.31 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 48 48 53 60 60 68 68 68 75.5 75.5 75.5 95 112 135 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm SR 90° Elbow C- E (in/mm)C- E (in/mm)C- E (in/mm) 45° Elbow SR Straight Te eMax.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 1.89 1.89 2.09 2.36 2.36 2.68 2.68 2.68 2.97 2.97 2.97 3.74 4.41 5.31 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 GROOVED FITTINGS 13 Pr e s s u r e D r o p (f t o f s c h e d u l e 4 0 p i p e ) Flow Rate (ft./sec.) SHORT PATTERN 45° ELBOW PRESSURE DROP SHORT PATTERN TEE31T+ ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 48 48 53 60 60 68 68 68 75.5 75.5 75.5 95 112 135 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm SR 90° Elbow C- E (in/mm)C- E (in/mm)C- E (in/mm) 45° Elbow SR Straight Te eMax.Wo rkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 1.89 1.89 2.09 2.36 2.36 2.68 2.68 2.68 2.97 2.97 2.97 3.74 4.41 5.31 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 70 76 76 85 102 102 121 121 121 130 130 140 175 215 220 48 48 53 60 60 68 68 68 75.5 75.5 75.5 95 112 135 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 NominalSizein/mm PipeO.D.in/mm SR 90° Elbow C- E (in/mm)C- E (in/mm)C- E (in/mm) 45° Elbow SR Straight Te eMax.WorkingPressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 2.76 2.99 2.99 3.35 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.89 8.46 8.66 1.89 1.89 2.09 2.36 2.36 2.68 2.68 2.68 2.97 2.97 2.97 3.74 4.41 5.31 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 GROOVED FITTINGS 14 F low R a te (ft./s ec.) Pr e s s u r e D r o p (f t o f s c h e d u l e 4 0 p i p e ) Flow Rate (ft./sec.) SHORT PATTERN TEE PRESSURE DROP STRAIGHT TEE ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31T GROOVED FITTINGS NominalSizein/mm PipeO.D.in/mm Te e C- E Cross Cross C- E C- E 45° Lateral C- LE C- SE Max.Wo rkingPressurePSI/Bar 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 178 197 197 216 267 318 318 356 457 521 584 70 76 76 83 95 102 102 114 152 165 178 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 57 70 70 84 95 95 108 127 127 140 140 140 165 165 165 197 229 254 70 76 76 86 102 102 121 121 121 130 130 140 174 215 245 57 70 70 84 95 95 108 127 127 140 140 140 165 165 165 197 229 254 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 7.00 7.75 7.75 8.50 10.50 12.50 12.50 14.00 18.00 20.50 23.00 2.75 3.00 3.00 3.25 3.75 4.00 4.00 4.50 6.00 6.50 7.00 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 2.24 2.76 2.76 3.31 3.74 3.74 4.25 5.00 5.00 5.51 5.51 5.51 6.50 6.50 6.50 7.76 9.02 10.00 2.76 2.99 2.99 3.39 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.85 8.46 9.65 2.24 2.76 2.76 3.31 3.74 3.74 4.25 5.00 5.00 5.51 5.51 5.51 6.50 6.50 6.50 7.76 9.02 10.00 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 15 ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative GROOVED CROSS31X GROOVED FITTINGS NominalSizein/mm PipeO.D.in/mm Te e C- E Cross Cross C- E C- E 45° Lateral C- LE C- SE Max.Wo rkingPressurePSI/Bar 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 178 197 197 216 267 318 318 356 457 521 584 70 76 76 83 95 102 102 114 152 165 178 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 57 70 70 84 95 95 108 127 127 140 140 140 165 165 165 197 229 254 70 76 76 86 102 102 121 121 121 130 130 140 174 215 245 57 70 70 84 95 95 108 127 127 140 140 140 165 165 165 197 229 254 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 7.00 7.75 7.75 8.50 10.50 12.50 12.50 14.00 18.00 20.50 23.00 2.75 3.00 3.00 3.25 3.75 4.00 4.00 4.50 6.00 6.50 7.00 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 2.24 2.76 2.76 3.31 3.74 3.74 4.25 5.00 5.00 5.51 5.51 5.51 6.50 6.50 6.50 7.76 9.02 10.00 2.76 2.99 2.99 3.39 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.85 8.46 9.65 2.24 2.76 2.76 3.31 3.74 3.74 4.25 5.00 5.00 5.51 5.51 5.51 6.50 6.50 6.50 7.76 9.02 10.00 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 NominalSizein/mm PipeO.D.in/mm Te e C- E Cross Cross C- E C- E 45° Lateral C- LE C- SE Max.Wo rkingPressurePSI/Bar 25 32 40 50 65 65 80 100 100 125 125 125 150 150 150 200 250 300 178 197 197 216 267 318 318 356 457 521 584 70 76 76 83 95 102 102 114 152 165 178 33.7 42.4 48.3 60.3 73 76.1 88.9 108 114.3 133 139.7 141.3 159 165.1 168.3 219.1 273 323.9 57 70 70 84 95 95 108 127 127 140 140 140 165 165 165 197 229 254 70 76 76 86 102 102 121 121 121 130 130 140 174 215 245 57 70 70 84 95 95 108 127 127 140 140 140 165 165 165 197 229 254 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 4 4 5 5 5 6 6 6 8 10 12 7.00 7.75 7.75 8.50 10.50 12.50 12.50 14.00 18.00 20.50 23.00 2.75 3.00 3.00 3.25 3.75 4.00 4.00 4.50 6.00 6.50 7.00 1.327 1.669 1.9 2.375 2.875 3 3.5 4.25 4.5 5.25 5.5 5.563 6.25 6.5 6.625 8.625 10.75 12.75 2.24 2.76 2.76 3.31 3.74 3.74 4.25 5.00 5.00 5.51 5.51 5.51 6.50 6.50 6.50 7.76 9.02 10.00 2.76 2.99 2.99 3.39 4.02 4.02 4.76 4.76 4.76 5.12 5.12 5.51 6.85 8.46 9.65 2.24 2.76 2.76 3.31 3.74 3.74 4.25 5.00 5.00 5.51 5.51 5.51 6.50 6.50 6.50 7.76 9.02 10.00 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 16 GROOVED REDUCING TEE ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31RT GROOVED FITTINGS 50×32 50×40 65×32 65×40 65×50 65×32 65×40 65×50 80×32 80×40 80×50 80×65 80×65 100×32 100×40 100×50 100×65 100×65 100×80 125×50 125×65 125×80 125×100 125×100 125×125 125×50 125×65 125×80 125×100 150×65 150×80 60.3×42.4 60.3×48.3 73×42.4 73×48.3 73×60.3 76.1×42.4 76.1×48.3 76.1×60.3 88.9×42.4 88.9×48.3 88.9×60.3 88.9×73 88.9×76.1 114.3×42.4 114.3×48.3 114.3×60.3 114.3×73 114.3×76.1 114.3×88.9 139.7×60.3 139.7×76.1 139.7×88.9 139.7×108 139.7×114.3 139.7×133 141.3×60.3 141.3×73 141.3×88.9 141.3×114.3 159×76.1 159×88.9 NominalSizein/mm Pipe O.D.in/mm Max.WorkingPressurePSI/Bar Dimensions C-Ein/mm C1-E1in/mm 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 70 70 76 76 76 76 76 76 86 86 86 86 86 90 90 102 102 102 102 105 105 105 105 105 105 105 105 105 105 110 110 70 70 76 76 76 76 76 76 86 86 86 86 86 98* 98* 102 102 102 102 105 105 105 105 105 105 105 105 105 105 120* 120* 150×50 150×65 150×80 150×100 150×125 150×50 150×65 150×80 150×100 150×125 200×65 200×80 200×100 00×125 200×150 200×150 250×80 250×100 250×125 250×125 250×125 250×150 250×150 250×150 250×200 300×150 300×150 300×150 300×200 300×250 165.1×60.3 165.1×76.1 165.1×88.9 165.1×114.3 165.1×139.7 168.3×60.3 168.3×76.1 168.3×88.9 168.3×114.3 168.3×139.7 219.1×76.1 219.1×88.9 219.1×114.3 219.1×139.7 219.1×159 219.1×165.1 273×88.9 273×114.3 273×133 273×139.7 273×141.3 273×159 273×165.1 273×168.3 273×219.1 323.9×159 323.9×165.1 323.9×168.3 323.9×219.1 323.9×273 NominalSizein/mm Pipe O.D.in/mm Max.WorkingPressurePSI/Bar Dimensions C-Ein/mm C1-E1in/mm 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 130 130 130 130 130 140 140 140 140 140 174 174 174 174 174 174 190 190 190 190 190 190 190 190 190 220 220 220 220 220 130 130 130 130 130 140 140 140 140 140 174 174 174 174 174 174 190 190 190 190 190 190 190 190 190 220 220 220 220 220 2×1-1/4 2×1-1/2 2-1/2x1-1/4 2-1/2x1-1/2 2-1/2x2 2-1/2x1-1/4 2-1/2x1-1/2 2-1/2x2 3x1-1/4 3x1-1/2 3×2 3x2-1/2 3x2-1/2 4x1-1/4 4x1-1/2 4×2 4x2-1/2 4x2-1/2 4×3 5×2 5x2-1/2 5×3 5×4 5×4 5×5 5×2 5x2-1/2 5×3 5×4 6x2-1/2 6×3 2.375×1.669 2.375×1.9 2.875×1.669 2.875×1.9 2.875×2.375 3×1.669 3×1.9 3×2.375 3.5×1.669 3.5×1.9 3.5×2.375 3.5×2.875 3.5×3 4.5×1.669 4.5×1.9 4.5×2.375 4.5×2.875 4.5×3 4.5×3.5 5.5×2.375 5.5×3 5.5×3.5 5.5×4.25 5.5×4.5 5.5×5.25 5.563×2.375 5.563×2.875 5.563×3.5 5.563×4.5 6.25×3 6.25×3.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 2.76 2.76 2.99 2.99 2.99 2.99 2.99 2.99 3.39 3.39 3.39 3.39 3.39 3.54 3.54 4.02 4.02 4.02 4.02 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.33 4.33 2.76 2.76 2.99 2.99 2.99 2.99 2.99 2.99 3.39 3.39 3.39 3.39 3.39 3.86 3.86 4.02 4.02 4.02 4.02 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.72 4.72 6×2 6x2-1/2 6×3 6×4 6×5 6×2 6x2-1/2 6×3 6×4 6×5 8x2-1/2 8×3 8×4 8×5 8×6 8×6 10×3 10×4 10×5 10×5 10×5 10×6 10×6 10×6 10×8 12×6 12×6 12×6 12×8 12×10 6.5×2.375 6.5×3 6.5×3.5 6.5×4.5 6.5×5.5 6.625×2.375 6.625×3 6.625×3.5 6.625×4.5 6.625×5.5 8.625×3 8.625×3.5 8.625×4.5 8.625×5.5 8.625×6.25 8.625×6.5 10.75×3.5 10.75×4.5 10.75×5.25 10.75×5.5 10.75×5.563 10.75×6.25 10.75×6.5 10.75×6.625 10.75×8.625 12.75×6.25 12.75×6.5 12.75×6.625 12.75×8.625 12.75×10.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 5.12 5.12 5.12 5.12 5.12 5.51 5.51 5.51 5.51 5.51 6.85 6.85 6.85 6.85 6.85 6.85 7.48 7.48 7.48 7.48 7.48 7.48 7.48 7.48 7.48 8.66 8.66 8.66 8.66 8.66 5.12 5.12 5.12 5.12 5.12 5.51 5.51 5.51 5.51 5.51 6.85 6.85 6.85 6.85 6.85 6.85 7.48 7.48 7.48 7.48 7.48 7.48 7.48 7.48 7.48 8.66 8.66 8.66 8.66 8.66 17 THREADED REDUCING TEE ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 21RTS GROOVED FITTINGS 50×25 50×32 50×40 65×25 65×32 65×40 65×50 65×25 65×32 65×40 65×50 80×25 80×32 80×40 80×50 80×65 100×40 100×50 100×65 100×80 100×25 100×32 100×40 100×50 100×65 100×80 125×50 125×65 125×80 125×100 70 70 70 76 76 76 76 76 76 76 76 86 86 86 86 86 90 90 90 90 90 90 90 90 90 90 105 105 105 105 70 70 70 76 76 76 76 76 76 76 76 86 86 86 86 86 98* 98* 98* 98* 98* 98* 98* 98* 98* 98* 105 105 105 105 60.3×33.7 60.3×42.4 60.3×48.3 73.0×33.7 73.0×42.4 73.0×48.3 73.0×60.3 76.1×33.7 76.1×42.4 76.1×48.3 76.1×60.3 88.9×33.7 88.9×42.4 88.9×48.3 88.9×60.3 88.9×76.1 108.0×48.3 108.0×60.3 108.0×76.1 108×88.9 114.3×33.7 114.3×42.4 114.3×48.3 114.3×60.3 114.3×76.1 114.3×88.9 133.0×60.3 133.0×76.1 133.0×88.9 133.0×114.3 NominalSizein/mm Pipe O.D.in/mm Max.WorkingPressurePSI/Bar Dimensions C-Ein/mm C1-E1in/mm 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 125×40 125×50 125×65 125×80 125×100 125×40 125×50 125×65 125×80 125×100 150×40 150×50 150×65 150×80 150×100 150×40 150×50 150×65 150×80 150×100 150×40 150×50 150×65 150×80 150×100 200×50 200×50 200×80 200×100 105 105 105 105 105 105 105 105 105 105 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 146 146 146 146 105 105 105 105 105 105 105 105 105 105 120* 120* 120* 120* 120* 120* 120* 120* 120* 120* 120* 120* 120* 120* 120* 146 146 146 146 139.7×48.3 139.7×60.3 139.7×76.1 139.7×88.9 139.7×114.3 141.3×48.3 141.3×60.3 141.3×76.1 141.3×88.9 141.3×114.3 159.0×48.3 159.0×60.3 159.0×76.1 159.0×88.9 159.0×114.3 165.1×48.3 165.1×60.3 165.1×76.1 165.1×88.9 165.1×114.3 168.3×48.3 168.3×60.3 168.3×76.1 168.3×88.9 168.3×114.3 219.1×60.3 219.1×76.1 219.1×88.9 219.1×114.3 NominalSizein/mm Pipe O.D.in/mm Max.Wo rkingPressurePSI/Bar Dimensions C-Ein/mm C1-E1in/mm 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2×1 2×1-1/4 2×1-1/2 2-1/2×1 2-1/2x1-1/4 2-1/2x1-1/2 2-1/2x2 2-1/2x1 2-1/2x1-1/4 2-1/2x1-1/2 2-1/2x2 3×1 3x1-1/4 3x1-1/2 3×2 3×2-1/2 4×1-1/2 4×2 4×2-1/2 4×3 4×1 4×1-1/4 4×1-1/2 4×2 4×2-1/2 4×3 5×2 5×2-1/2 5×3 5×4 2.76 2.76 2.76 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 3.39 3.39 3.39 3.39 3.39 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 4.13 4.13 4.13 4.13 2.76 2.76 2.76 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 3.39 3.39 3.39 3.39 3.39 3.86 3.86 3.86 3.86 3.86 3.86 3.86 3.86 3.86 3.86 4.13 4.13 4.13 4.13 2.375×1.327 2.375×1.669 2.375×1.9 2.875×1.327 2.875×1.669 2.875×1.9 2.875×2.375 3×1.327 3×1.669 3×1.9 3×2.375 3.5×1.327 3.5×1.669 3.5×1.9 3.5×2.375 3.5×3 4.25×1.9 4.25×2.375 4.25×3 4.25×3.5 4.5×1.327 4.5×1.669 4.5×1.9 4.5×2.375 4.5×3 4.5×3.5 5.25×2.375 5.25×3 5.25×3.5 5.25×4.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 5×1-1/2 5×2 5×2-1/2 5×3 5×4 5×1-1/2 5×2 5×2-1/2 5×3 5×4 6×1-1/2 6×2 6×2-1/2 6×3 6×4 6×1-1/2 6×2 6×2-1/2 6×3 6×4 6×1-1/2 6×2 6×2-1/2 6×3 6×4 8×2 8×2-1/2 8×3 8×4 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 5.75 5.75 5.75 5.75 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 5.75 5.75 5.75 5.75 5.5×1.9 5.5×2.375 5.5×3 5.5×3.5 5.5×4.5 5.563×1.9 5.563×2.375 5.563×3 5.563×3.5 5.563×4.5 6.25×1.9 6.25×2.375 6.25×3 6.25×3.5 6.25×4.5 6.5×1.9 6.5×2.375 6.5×3 6.5×3.5 6.5×4.5 6.625×1.9 6.625×2.375 6.625×3 6.625×3.5 6.625×4.5 8.625×2.375 8.625×3 8.625×3.5 8.625×4.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 18 GROOVED REDUCING CROSS ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31X GROOVED FITTINGS NominalSizein/mm Pipe O.D.in/mm Max.WorkingPressurePSI/Bar Dimensions C-Ein/mm C1-E1in/mm NominalSizein/mm Pipe O.D.in/mm Max.WorkingPressurePSI/Bar Dimensions C-Ein/mm C1-E1in/mm 65×32 65×40 65×50 65×32 65×40 65×50 80×32 80×40 80×50 80×65 100×50 100×65 100×80 100×32 100×40 100×50 100×65 100×80 125×65 125×80 125×100 125×100 125×50 125×65 125×80 125×100 125×100 125×50 125×65 125×80 76 76 76 76 76 76 86 86 86 86 90 90 90 90 90 90 90 90 105 105 105 105 105 105 105 105 105 105 105 105 76 76 76 76 76 76 86 86 86 86 98 98 98 98 98 98 98 98 105 105 105 105 105 105 105 105 105 105 105 105 73×42.4 73×48.3 73×60.3 76.1×42.4 76.1×48.3 76.1×60.3 88.9×42.4 88.9×48.3 88.9×60.3 88.9×76.1 108×60.3 108×76.1 108×88.9 114.3×42.4 114.3×48.3 114.3×60.3 114.3×76.1 114.3×88.9 133×76.1 133×88.9 133×108 133×114.3 139.7×60.3 139.7×76.1 139.7×88.9 139.7×108 139.7×114.3 141.3×60.3 141.3×73 141.3×88.9 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 125×100 125×100 150×65 150×80 150×100 150×100 150×125 150×50 150×65 150×80 150×100 150×100 150×125 150×125 150×50 150×65 150×80 150×100 150×100 150×125 150×125 200×65 200×80 200×100 200×100 200×125 200×125 200×150 200×150 105 105 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 146 146 146 146 146 146 146 146 105 105 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 146 146 146 146 146 146 146 146 141.3×108 141.3×114.3 159×76.1 159×88.9 159×108 159×114.3 159×133 165.1×60.3 165.1×76.1 165.1×88.9 165.1×108 165.1×114.3 165.1×133 165.1×139.7 168.3×60.3 168.3×76.1 168.3×88.9 168.3×108 168.3×114.3 168.3×133 168.3×139.7 219.1×76.1 219.1×88.9 219.1×108 219.1×114.3 219.1×133 219.1×139.7 219.1×159 219.1×165.1 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2-1/2x1-1/4 2-1/2x1-1/2 2-1/2x2 2-1/2x1/4 2-1/2x1-1/2 2-1/2x2 3x1-1/4 3x1-1/2 3×2 3x2-1/2 4×2 4x2-1/2 4×3 4x1-1/4 4x1-1/2 4×2 4x2-1/2 4×3 5x2-1/2 5×3 5×4 5×4 5×2 5x2-1/2 5×3 5×4 5×4 5×2 5x2-1/2 5×3 2.99 2.99 2.99 2.99 2.99 2.99 3.39 3.39 3.39 3.39 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 2.99 2.99 2.99 2.99 2.99 2.99 3.39 3.39 3.39 3.39 3.86 3.86 3.86 3.86 3.86 3.86 3.86 3.86 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 4.13 2.875×1.669 2.875×1.9 2.875×2.375 3×1.669 3×1.9 3×2.375 3.5×1.669 3.5×1.9 3.5×2.375 3.5×3 4.25×2.375 4.25×3 4.25×3.5 4.5×1.669 4.5×1.9 4.5×2.375 4.5×3 4.5×3.5 5.25×3 5.25×3.5 5.25×4.25 5.25×4.5 5.5×2.375 5.5×3 5.5×3.5 5.5×4.25 5.5×4.5 5.563×2.375 5.563×2.875 5.563×3.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 5×4 5×4 6x2-1/2 6×3 6×4 6×4 6×5 6×2 6x2-1/2 6×3 6×4 6×4 6×5 6×5 6×2 6x2-1/2 6×3 6×4 6×4 6×5 6×5 8x2-1/2 8×3 8×4 8×4 8×5 8×5 8×6 8×6 4.13 4.13 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 4.33 5.75 5.75 5.75 5.75 5.75 5.75 5.75 5.75 4.13 4.13 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 4.72 5.75 5.75 5.75 5.75 5.75 5.75 5.75 5.75 5.563×4.25 5.563×4.5 6.25×3 6.25×3.5 6.25×4.25 6.25×4.5 6.25×5.25 6.5×2.375 6.5×3 6.5×3.5 6.5×4.25 6.5×4.5 6.5×5.25 6.5×5.5 6.625×2.375 6.625×3 6.625×3.5 6.625×4.25 6.625×4.5 6.625×5.25 6.625×5.5 8.625×3 8.625×3.5 8.625×4.25 8.625×4.5 8.625×5.25 8.625×5.5 8.625×6.25 8.625×6.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 19 DRAIN ELBOW ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 2601 GROOVED FITTINGS 50 65 80 100 125 150 60.3 73 88.9 114.3 141.3 168.3 20 20 20 20 20 20 83 95 108 127 140 165 70 70 70 70 70 70 37.5 45 55 68.5 82 95.5 2 2-1/2 3 4 5 6 2.375 2.875 3.5 4.5 5.563 6.625 300 300 300 300 300 300 3.27 3.74 4.25 5.00 5.51 6.50 2.76 2.76 2.76 2.76 2.76 2.76 1.48 1.77 2.17 2.70 3.23 3.76 NominalSizein/mm PipeO.D.in/mm Dimensions C - Ein/mm Din/mm Ein/mm Max.Wo rkingPressurePSI/Bar 20 1” NPT REDUCING END OF LINE ELBOW ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Female NPT Threads conform to ASME B1.20.1 ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 31AE GROOVED FITTINGS 15 20 25 15 20 25 15 20 25 15 20 25 20 20 20 20 20 20 20 20 20 20 20 20 61 61 61 64 64 64 70 70 70 76 76 76 32×15 32×20 32×25 40×15 40×20 40×25 50×15 50×20 50×25 65×15 65×20 65×25 1/2 3/4 1 1/2 3/4 1 1/2 3/4 1 1/2 3/4 1 300 300 300 300 300 300 300 300 300 300 300 300 2.40 2.40 2.40 2.52 2.52 2.52 2.76 2.76 2.76 2.99 2.99 2.99 1-1/4×1/2 1-1/4×3/4 1-1/4×1 1-1/2×1/2 1-1/2×3/4 1-1/2×1 2×1/2 2×3/4 2×1 2-1/2×1/2 2-1/2×3/4 2-1/2×1 NominalSizein/mm BSP/NPT C - Ein/mm Max.WorkingPressurePSI/Bar 21 ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative GROOVED CONCENTRIC REDUCER21CR GROOVED FITTINGS 40×32 50×32 50×40 65×32 65×40 65×50 65×40 65×50 80×32 80×40 80×50 80×65 80×65 100×32 100×40 100×50 100×65 100×65 100×80 125×50 125×50 125×65 125×65 125×80 48.3×42.4 60.3×42.4 60.3×48.3 73×42.4 73×48.3 73×60.3 76.1×48.3 76.1×60.3 88.9×42.4 88.9×48.3 88.9×60.3 88.9×73 88.9×76.1 114.3×42.4 114.3×48.3 114.3×60.3 114.3×73 114.3×76.1 114.3×88.9 133×60.3 139.7×60.3 139.7×73 139.7×76.1 139.7×88.9 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 64 64 64 64 64 64 64 64 64 64 64 64 64 76 76 76 76 76 76 85 85 85 85 85 Nominal Sizein/mm Pipe O.D.in/mm E - Ein/mm Max.WorkingPressurePSI/Bar 125×100 125×100 125×50 125×65 125×65 125×80 125×100 150×50 150×100 150×100 150×125 150×50 150×65 150×65 150×100 150×100 150×125 150×125 150×50 150×65 150×65 150×80 150×100 150×125 139.7×108 139.7×114.3 141.3×60.3 141.3×73 141.3×76.1 141.3×88.9 141.3×114.3 159×60.3 159×108 159×114.3 159×139.7 165.1×60.3 165.1×73 165.1×76.1 165.1×108 165.1×114.3 165.1×133 165.1×139.7 168.3×60.3 168.3×73 168.3×76.1 168.3×88.9 168.3×114.3 168.3×139.7 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 1-1/2×1-1/4 2×1-1/4 2×1-1/2 2-1/2×1-1/4 2-1/2×1-1/2 2-1/2×2 2-1/2×1-1/2 2-1/2×2 3×1-1/4 3×1-1/2 3×2 3×2-1/2 3×2-1/2 4×1-1/4 4×1-1/2 4×2 4×2-1/2 4×2-1/2 4×3 5×2 5×2 5×2-1/2 5×2-1/2 5×3 1.9×1.669 2.375×1.669 2.375×1.9 2.875×1.669 2.875×1.9 2.875×2.375 3×1.9 3×2.375 3.5×1.669 3.5×1.9 3.5×2.375 3.5×2.875 3.5×3 4.5×1.669 4.5×1.9 4.5×2.375 4.5×2.875 4.5×3 4.5×3.5 5.25×2.375 5.5×2.375 5.5×2.875 5.5×3 5.5×3.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.99 2.99 2.99 2.99 2.99 2.99 3.35 3.35 3.35 3.35 3.35 5×4 5×4 5×2 5×2-1/2 5×2-1/2 5×3 5×4 6×2 6×4 6×4 6×5 6×2 6×2-1/2 6×2-1/2 6×4 6×4 6×5 6×5 6×2 6×2-1/2 6×2-1/2 6×3 6×4 6×5 5.5×4.25 5.5×4.5 5.563×2.375 5.563×2.875 5.563×3 5.563×3.5 5.563×4.5 6.25×2.375 6.25×4.25 6.25×4.5 6.25×5.5 6.5×2.375 6.5×2.875 6.5×3 6.5×4.25 6.5×4.5 6.5×5.25 6.5×5.5 6.63×2.375 6.625×2.875 6.625×2.375 6.625×3.5 6.625×4.5 6.625×5.5 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 Nominal Sizein/mm Pipe O.D.in/mm E - Ein/mm Max.Wo rkingPressurePSI/Bar 200×65 200×80 200×100 200×125 200×150 200×150 200×150 250×100 250×125 250×150 250×150 250×200 300×100 300×125 300×150 300×150 300×200 300×250 219.1×76.1 219.1×88.9 219.1×114.3 219.1×139.7 219.1×159 219.1×165.1 219.1×168.3 273×114.3 273×139.7 273×159 273×165.1 273×219.1 323.9×114.3 323.9×139.7 323.9×159 323.9×165.1 323.9×219.1 323.9×273 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 85 85 85 85 85 85 85 90 90 90 90 90 90 90 90 90 90 90 8×2-1/2 8×3 8×4 8×5 8×6 8×6 8×6 10×4 10×5 10×6 10×6 10×8 12×4 12×5 12×6 12×6 12×8 12×10 8.63×3 8.625×3.5 8.625×4.5 8.625×5.5 8.625×6.25 8.63×6.5 8.625×6.63 10.75×4.5 10.75×5.5 10.75×6.25 10.75×6.5 10.75×8.625 12.75×4.5 12.75×5.5 12.75×6.25 12.75×6.625 12.75×8.63 12.75×10.75 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 22 THREADED CONCENTRIC REDUCER ▪Ductile Iron ASTM A-536 Grade 65-45-12 ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 21MG GROOVED FITTINGS 50×25 50×32 50×40 65×25 65×32 65×40 65×50 65×25 65×32 65×40 65×50 80×25 80×32 80×40 80×50 80×65 100×25 100×32 100×40 100×50 100×65 100×80 100×25 100×32 100×40 100×50 100×65 100×65 100×80 125×25 125×32 125×40 125×50 60.3×33.7 60.3x42.4 60.3x48.3 73x33.7 73x42.4 73x48.3 73x60.3 76.1x33.7 76.1x42.4 76.1x48.3 76.1x60.3 88.9x33.7 88.9x42.4 88.9x48.3 88.9x60.3 88.9x76.1 108.0×33.7 108.0×42.4 108.0×48.3 108.0×60.3 108.0×76.1 108×88.9 114.3×33.7 114.3×42.4 114.3×48.3 114.3×60.3 114.3×73 114.3×76.1 114.3×88.9 139.7×33.7 139.7×42.4 139.7×48.3 139.7×60.3 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 76 76 76 76 76 76 76 76 76 76 76 76 76 85 85 85 85 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Nominal Sizein/mm Pipe O.D.in /mm E - Ein/mm Max.Working PressurePSI/Bar 125×65 125×80 125×100 125×25 125×32 125×40 125×50 125×65 125×80 125×80 150×25 150×32 150×40 150×50 150×65 150×80 150×100 150×25 150×32 150×40 150×50 150×65 150×65 150×80 150×100 200×25 200×32 200×40 200×50 200×65 200×65 200×80 200×100 139.7×76.1 139.7×88.9 139.7×114.3 141.3×33.7 141.3×42.4 141.3×48.3 141.3×60.3 141.3×73 141.3×88.9 141.3×114.3 165.1×33.7 165.1×42.4 165.1×48.3 165.1×60.3 165.1×76.1 165.1×88.9 165.1×114.3 168.3×33.7 168.3×42.4 168.3×48.3 168.3×60.3 168.3×73 168.3×76.1 168.3×88.9 168.3×114.3 219.1×33.7 219.1×42.4 219.1×48.3 219.1×60.3 219.1×73 219.1×76.1 219.1×88.9 219.1×114.3 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 2×1 2x1-1/4 2x1-1 /2 2-1/2x1 2-1 /2 x1 -1/4 2-1 /2 x1 -1/2 2-1/2x2 2-1/2x1 2-1 /2 x1 -1/4 2-1/2x1-1/2 2-1/2x2 3×1 3x1-1/4 3x1-1/2 3×2 3x2-1/2 4×1 4x1-1/4 4x1-1 /2 4×2 4x2-1/2 4×3 4×1 4x1-1 /4 4x1-1/2 4×2 4x2-1/2 4x2-1/2 4×3 5×1 5x1-1 /4 5x1-1/2 5×2 2.375×1.327 2.375×1.669 2.375×1.9 2.875×1.327 2.875×1.669 2.875×1.9 2.875×2.375 3×1.327 3×1.669 3×1.9 3×2.375 3.5×1.327 3.5×1.669 3.5×1.9 3.5×2.375 3.5×3 4.25×1.327 4.25×1.669 4.25×1.9 4.25×2.375 4.25×3 4.25×3.5 4.5×1.327 4.5×1.669 4.5×1.9 4.5×2.375 4.5×2.875 4.5×3 4.5×3.5 5.5×1.327 5.5×1.669 5.5×1.9 5.5×2.375 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 2.99 3.35 3.35 3.35 3.35 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 5x2-1/2 5×3 5×4 5×1 5x1-1/4 5x1-1/2 5×2 5x2-1 /2 5×3 5×3 6×1 6x1-1/4 6x1-1/2 6×2 6x2-1 /2 6×3 6×4 6×1 6x1-1 /4 6x1-1/2 6×2 6x2-1 /2 6x2-1/2 6×3 6×4 8×1 8x1-1/4 8x1-1/2 8×2 8x2-1/2 8x2-1 /2 8×3 8×4 5.5×3 5.5×3.5 5.5×4.5 5.563×1.327 5.563×1.669 5.563×1.9 5.563×2.375 5.563×2.875 5.563×3.5 5.563×4.5 6.5×1.327 6.5×1.669 6.5×1.9 6.5×2.375 6.5×3 6.5×3.5 6.5×4.5 6.625×1.327 6.625×1.669 6.625×1.9 6.625×2.375 6.625×2.875 6.625×3 6.625×3.5 6.625×4.5 8.625×1.327 8.625×1.669 8.625×1.9 8.625×2.375 8.625×2.875 8.625×3 8.625×3.5 8.625×4.5 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 Nominal Sizein/mm Pipe O.D.in /mm E - Ein/mm Max.Working PressurePSI/Bar 23 GROOVED END CAP ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪For current listing/approval details contact a Titus representative 21C ECCENTRIC DRAIN CAP31DC GROOVED FITTINGS Nominal Sizein/mm Pipe O.D.in /mm E - Ein/mm Max.Working PressurePSI/Bar 25 32 40 50 65 80 100 100 125 125 33.7 42.4 48.3 60.3 76.1 88.9 108 114.3 133 139.7 20 20 20 20 20 20 20 20 20 20 23.8 23.8 23.8 23.8 23.8 23.8 25.4 25.4 25.4 25.4 125 150 150 150 200 250 300 141.3 159 165.1 168.3 219.1 273 323.9 20 20 20 20 20 20 20 25.4 25.4 25.4 25.4 30.2 32 32 1 1-1/4 1-1/2 2 2-1/2 3 4 4 5 5 1.327 1.669 1.9 2.375 3 3.5 4.25 4.5 5.25 5.5 300 300 300 300 300 300 300 300 300 300 0.94 0.94 0.94 0.94 0.94 0.94 1.00 1.00 1.00 1.00 5 5 6 6 8 10 12 5.563 6.25 6.5 6.625 8.625 10.750 12.75 300 300 300 300 300 300 300 1.00 1.00 1.00 1.00 1.19 1.26 1.26 80×50 100×25 100×32 100×40 100×50 125×50 125×50 150×25 150×50 150×32 150×40 150×50 200×50 88.9×60.3 114.3×33.7 114.3×42.4 114.3×48.3 114.3×60.3 139.7×60.3 141.3×60.3 165.1×33.7 165.1×60.3 168.3×42.4 168.3×48.3 168.3×60.3 219.1×60.3 23.8 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 30.2 20 20 20 20 20 20 20 20 20 20 20 20 20 50×25 50×32 50×40 65×25 65×32 65×40 65×50 65×25 65×32 65×40 65×50 80×25 80×32 80×40 60.3×33.7 60.3×42.4 60.3×48.3 73x33.7 73x42.4 73x48.3 73.0×60.3 76.1×33.7 76.1×42.4 76.1×48.3 76.1×60.3 88.9×33.7 88.9×42.4 88.9×48.3 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 Nominal SizeGrooved X Threadedin/mm E - Ein/mm PipeO.D.in/mm Max.Wo rking PressurePSI/Bar 20 20 20 20 20 20 20 20 20 20 20 20 20 20 3×2 4x1 4x1-1/2 4x1-1/2 4×2 5×2 5×2 6×1 6×2 6x1-1/4 6x1-1/2 6×2 8×2 3.5×2.375 4.5×1.327 4.5×1.669 4.5×1.9 4.5×2.375 5.5×2.375 5.563×2.375 6.5×1.327 6.5×2.375 6.625×1.669 6.63×1.9 6.63×2.375 8.625×2.375 0.94 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.19 300 300 300 300 300 300 300 300 300 300 300 300 300 2×1 2x1-1 /4 2x1-1/2 2-1/2x1 2-1/2x1-1/4 2-1/2 x1-1 /2 2-1/2 x2 2-1/2x1 2-1/2x1-1/4 2-1/2 x1-1 /2 2-1/2x2 3×1 3x1-1/4 3x1-1/2 2.375×1.327 2.375×1.669 2.375×1.9 2.875×1.327 2.875×1.669 2.875×1.9 2.875×2.375 3×1.327 3×1.669 3×1.9 3×2.375 3.5×1.327 3.5×1.669 3.5×1.9 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 0.94 300 300 300 300 300 300 300 300 300 300 300 300 300 300 24 SADDLE-LET OUTLET TEE U BOLT MECHANICAL TEE ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Female NPT Threads conform to ASME B1.20.1 ▪Finish available in electro zinc plated or orange epoxy paint ▪Gasket: Grade E – EPDM with operating temperature of -30F to 230F (-34C to 110C) and is marked by a green stripe ▪Bolts are SAE J429 Grade 5 ▪Pressure rated up to 300p ▪For current listing/approval details contact a Titus representative 41 MECHANICAL TEES 25×15 25×20 32×15 32×20 32×25 40×15 40×20 40×25 50×15 50×20 50×25 65×15 65×20 65×25 80×25 24 24 30 30 30 30 30 30 30 30 30 30 30 30 30 46 46 53 53 56 55 55 58 64 64 67 69 69 72 80.5 74 74 89 89 89 89 89 89 98 98 98 111 111 111 128 NominalSizein/mm Hole Dia.+0.04, -0 /+1,-0 AB Dimensions - in /mm 44 44 56 56 56 56 56 56 56 56 56 56 56 56 56 C 25-30 25-30 30-40 30-40 30-40 30-40 30-40 30-40 30-40 30-40 30-40 30-40 30-40 30-40 30-40 Bolt To rqueLbs-Ft/N-M 5/16 5/16 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 40 40 44 44 47 46 46 49 53 53 56 58 58 61 67 1×1/2 1×3/4 1-1/4x1/2 1-1/4x3/4 1-1/4 x1 1-1/2 x1 /2 1-1/2x3/4 1-1/2 x1 2x1/2 2x3/4 2×1 2-1/2 x1/2 2-1/2 x3/4 2-1/2 x1 3×1 0.95 0.95 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.81 1.81 2.09 2.09 2.20 2.17 2.17 2.28 2.52 2.52 2.64 2.72 2.72 2.83 3.17 2.91 2.91 3.50 3.50 3.50 3.50 3.50 3.50 3.86 3.86 3.86 4.37 4.37 4.37 5.04 1.73 1.73 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 18-22 18-22 22-29 22-29 22-29 22-29 22-29 22-29 22-29 22-29 22-29 22-29 22-29 22-29 22-29 U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt U-Bolt 1.57 1.57 1.73 1.73 1.85 1.81 1.81 1.93 2.09 2.09 2.20 2.28 2.28 2.40 2.64 Bolt Sizein Ta ke-OutT/Din/mm 25 T ▪Ductile Iron ASTM A-536 Grade 65-45-12. ▪Female NPT Threads conform to ASME B1.20.1 ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪Gasket: Grade E – EPDM with operating temperature of -30F to 230F (-34C to 110C) and is marked by a green stripe ▪Bolts are SAE J429 Grade 5 ▪Pressure rated up to 300psi ▪For current listing/approval details contact a Titus representative MECHANICAL TEES MECHANICAL TEE - THREADED 31MT 38 38 38 44.5 44.5 38 38 38 44.5 50.8 38 38 38 44.5 50.8 38 38 38 44.5 50.8 63.5 38 46 53 64 80 38 38 38 44.5 50.8 63.5 70 89 38 46 53 60.3×21.3 60.3×26.7 60.3×33.7 60.3×42.4 60.3×48.3 73×21.3 73×26.7 73.0×33.7 73.0×42.4 73.0×48.3 76.1×21.3 76.1×26.7 76.1×33.7 76.1×42.4 76.1×48.3 88.9×21.3 88.9×26.7 88.9×33.7 88.9×42.4 88.9×48.3 88.9×60.3 108.1×33.7 108.0×42.4 108.0×48.3 108.0×60.3 108.0×76.1 114.3×21.3 114.3×26.7 114.3×33.7 114.3×42.4 114.3×48.3 114.3×60.3 114.3×76.1 114.3×88.9 133.0×33.7 133.0×42.4 133.0×48.3 42 42 42 42 42 47 47 47 47 47 48 48 48 48 48 55 55 55 55 55 55 62 62 62 62 62 65 65 65 65 65 65 65 65 74 74 74 120 120 120 120 120 143 143 143 143 143 143 143 143 143 143 158 158 158 158 158 158 167 167 167 167 167 181 181 181 181 181 181 181 181 205 205 205 NominalSizein/mm PipeO.D. Hole Dia.+0.13,-0/+3.2,-0 AB Dimensions - in /mm 76 76 76 84 84 76 76 76 84 90 76 76 76 84 90 76 76 76 84 90 101 76 83 90 100 117 76 76 76 84 90 101 117 136 76 83 90 CD 56 56 56 68 71 61.5 61.5 61.5 73.5 73.5 61.5 61.5 61.5 73.5 75 69.5 69.5 69.5 81 81 81 76 76 76 78 105 79 79 82 94 94 94 99 100 89 89 89 T‡ 50 50 47 52 52 56 56 53 58 58 56 56 53 58 58 64 63 61 65 71 70 73 78 83 83 73 77 76 73 78 83 83 73 84 85 90 95 M10×60 M10×60 M10×60 M10×60 M10×60 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×70 M12×70 M12×70 M12×70 M12×70 M12×70 M12×70 M12×70 M12×75 M12×75 M12×75 Bolt Sizein/mm 50×15 50×20 50×25 50×32 50×40 65×15 65×20 65×25 65×32 65×40 65×15 65×20 65×25 65×32 65×40 80×15 80×20 80×25 80×32 80×40 80×50 100×25 100×32 100×40 100×50 100×65 100×15 100×20 100×25 100×32 100×40 100×50 100×65 100×80 125×25 125×32 125×40 1.50 1.50 1.50 1.75 1.75 1.50 1.50 1.50 1.75 2.00 1.50 1.50 1.50 1.75 2.00 1.50 1.50 1.50 1.75 2.00 2.50 1.50 1.81 2.09 2.52 3.15 1.50 1.50 1.50 1.75 2.00 2.50 2.76 3.50 1.50 1.81 2.09 2.375×0.825 2.375×1.05 2.375×1.327 2.375×1.669 2.375×1.9 2.375×0.825 2.875×1.05 2.875×1.327 2.875×1.669 2.875×1.9 3×0.825 3×1.05 3×1.327 3×1.669 3×1.9 3.5×0.825 3.5×1.05 3.5×1.327 3.5×1.669 3.5×1.9 3.5×2.375 4.250×1.327 4.25×1.669 4.25×1.9 4.25×2.375 4.25×3 4.5×0.825 4.5×1.05 4.5×1.327 4.5×1.669 4.5×1.9 4.5×2.375 4.5×3 4.5×3.5 5.250×1.327 5.25×1.669 5.25×1.9 1.65 1.65 1.65 1.65 1.65 1.85 1.85 1.85 1.85 1.85 1.89 1.89 1.89 1.89 1.89 2.17 2.17 2.17 2.17 2.17 2.17 2.44 2.44 2.44 2.44 2.44 2.56 2.56 2.56 2.56 2.56 2.56 2.56 2.56 2.91 2.91 2.91 4.72 4.72 4.72 4.72 4.72 5.63 5.63 5.63 5.63 5.63 5.63 5.63 5.63 5.63 5.63 6.22 6.22 6.22 6.22 6.22 6.22 6.57 6.57 6.57 6.57 6.57 7.13 7.13 7.13 7.13 7.13 7.13 7.13 7.13 8.07 8.07 8.07 2.99 2.99 2.99 3.31 3.31 2.99 2.99 2.99 3.31 3.54 2.99 2.99 2.99 3.31 3.54 2.99 2.99 2.99 3.31 3.54 3.98 2.99 3.27 3.54 3.94 4.61 2.99 2.99 2.99 3.31 3.54 3.98 4.61 5.35 2.99 3.27 3.54 2.20 2.20 2.20 2.68 2.80 2.42 2.42 2.42 2.89 2.89 2.42 2.42 2.42 2.89 2.95 2.74 2.74 2.74 3.19 3.19 3.19 2.99 2.99 2.99 3.07 4.13 3.11 3.11 3.23 3.70 3.70 3.70 3.90 3.94 3.50 3.50 3.50 1.97 1.97 1.85 2.05 2.05 2.20 2.20 2.09 2.28 2.28 2.20 2.20 2.09 2.28 2.28 2.52 2.48 2.40 2.56 2.80 2.76 2.87 3.07 3.27 3.27 2.87 3.03 2.99 2.87 3.07 3.27 3.27 2.87 3.31 3.35 3.54 3.74 3/8×2-3/8 3/8×2-3/8 3/8×2-3/8 3/8×2-3/8 3/8×2-3/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2 ×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×3 1/2×3 1/2×3 2x1/2 2x3/4 2×1 2x1-1/4 2x1-1/2 2-1/2x1/2 2-1/2 x3/4 2-1/2 x1 2-1/2 x1-1 /4 2-1/2x1-1/2 2-1/2x1/2 2-1/2 x3/4 2-1/2x1 2-1/2 x1-1/4 2-1/2x1-1/2 3x1/2 3x3/4 3×1 3x1-1/4 3x1-1/2 3×2 4×1 4x1-1/4 4x1-1/2 4×2 4x2-1/2 4x1/2 4x3/4 4×1 4x1-1/4 4x1-1/2 4×2 4x2-1/2 4×3 5×1 5x1-1/4 5x1-1/2 26 MECHANICAL TEES MECHANICAL TEE - THREADED (CONTINUED) 31MT 64 80 92 38 44.5 50.8 63.5 70 89 38 44.5 50.8 63.5 70 89 38 46 53 64 80 92 118 38 44.5 50.8 63.5 70 89 114 38 44.5 50.8 63.5 70 89 114 38 44.5 50.8 63.5 70 89 114 133.0×60.3 133.0×76.1 133.0×88.9 139.7×33.7 139.7×42.4 139.7×48.3 139.7×60.3 139.7×76.1 139.7×88.9 141.3×33.7 141.3×42.4 141.3×48.3 141.3×60.3 141.3×76.1 141.3×88.9 159×33.7 159.0×42.4 159.0×48.3 159.0×60.3 159.0×76.1 159.0×88.9 159.0×114.3 165.1×33.7 165.1×42.4 165.1×48.3 165.1×60.3 165.1×76.1 165.1×88.9 165.1×114.3 168.3×33.7 168.3×42.4 168.3×48.3 168.3×60.3 168.3×76.1 168.3×88.9 168.3×114.3 219.1×33.7 219.1×42.4 219.1×48.3 219.1×60.3 219.1×76.1 219.1×88.9 219.1×114.3 74 74 74 77 77 77 77 77 77 77 77 77 77 77 77 91 91 91 91 91 91 91 94 94 94 94 94 94 94 97 97 97 97 97 97 97 125 125 125 125 125 125 125 205 205 205 219 219 219 219 219 219 219 219 219 219 219 219 233 233 233 233 233 233 233 248 248 248 248 248 248 248 248 248 248 248 248 248 248 322 322 322 322 322 322 322 NominalSizein/mm PipeO.D. Hole Dia.+0.13,-0 /+3.2,-0 AB Dimensions - in /mm 100 117 129 76 84 90 101 117 136 76 84 90 101 117 136 76 83 90 100 117 129 157 76 84 90 101 117 136 162 76 84 90 101 117 136 162 76 84 90 101 117 136 162 CD 89 92 94 96.5 107 107 108 115 118 96.5 107 107 108 115 118 101.5 101.5 101.5 101.5 105.5 105.5 110 108.5 120 120 121 126.5 129.5 136 108.5 120 120 121 128 131 139.5 136 147 147 147 156 158.5 167 T‡ 95 97 106 97 97 102 102 92 97 77 77 83 83 93 97 113 113 112 111 111 110 96.8 99 112 112 111 110 110 97 112 112 112 111 110 110 97 152 152 152 138 129 135 122 M12×75 M12×75 M12×75 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M14×75 M14×75 M14×75 M14×75 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M20×90 M20×90 M20×90 M20×90 M20×90 M20×90 M20×90 Bolt Sizein/mm 125×50 125×65 125×80 125×25 125×32 125×40 125×50 125×65 125×80 125×25 125×32 125×40 125×50 125×65 125×80 150×25 150×32 150×40 150×50 150×65 150×80 150×100 150×25 150×32 150×40 150×50 150×65 150×80 150×100 150×25 150×32 150×40 150×50 150×65 150×80 150×100 200×25 200×32 200×40 200×50 200×65 200×80 200×100 2.52 3.15 3.62 1.50 1.75 2.00 2.50 2.76 3.50 1.50 1.75 2.00 2.50 2.76 3.50 1.50 1.81 2.09 2.52 3.15 3.62 4.65 1.50 1.75 2.00 2.50 2.76 3.50 4.49 1.50 1.75 2.00 2.50 2.76 3.50 4.49 1.50 1.75 2.00 2.50 2.76 3.50 4.49 5.25×2.375 5.25×3 5.25×3.5 5.5×1.327 5.5×1.669 5.5×1.9 5.5×2.375 5.5×3 5.5×3.5 5.563×1.327 5.563×1.669 5.563×1.9 5.563×2.375 5.563×3 5.563×3.5 6.250×1.327 6.250×1.669 6.250×1.9 6.250×2.375 6.250×3 6.250×3.5 6.250×4.5 6.5×1.327 6.5×1.669 6.5×1.9 6.5×2.375 6.5×3 6.5×3.5 6.5×4.5 6.625×1.327 6.625×1.669 6.625×1.9 6.625×2.375 6.625×3 6.625×3.5 6.625×4.5 8.625×1.327 8.625×1.669 8.625×1.9 8.625×2.375 8.625×3 8.625×3.5 8.625×4.5 2.91 2.91 2.91 3.03 3.03 3.03 3.03 3.03 3.03 3.03 3.03 3.03 3.03 3.03 3.03 3.58 3.58 3.58 3.58 3.58 3.58 3.58 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.82 3.82 3.82 3.82 3.82 3.82 3.82 1.92 1.92 1.92 1.92 1.92 1.92 1.92 8.07 8.07 8.07 8.62 8.62 8.62 8.62 8.62 8.62 8.62 8.62 8.62 8.62 8.62 8.62 9.17 9.17 9.17 9.17 9.17 9.17 9.17 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 12.68 12.68 12.68 12.68 12.68 12.68 12.68 3.94 4.61 5.08 2.99 3.31 3.54 3.98 4.61 5.35 2.99 3.31 3.54 3.98 4.61 5.35 2.99 3.27 3.54 3.94 4.61 5.08 6.18 2.99 3.31 3.54 3.98 4.61 5.35 6.38 2.99 3.31 3.54 3.98 4.61 5.35 6.38 2.99 3.31 3.54 3.98 4.61 5.35 6.38 3.50 3.62 3.70 3.80 4.21 4.21 4.25 4.53 4.65 3.80 4.21 4.21 4.25 4.53 4.65 4.00 4.00 4.00 4.00 4.15 4.15 4.33 4.27 4.72 4.72 4.76 4.98 5.10 5.35 4.27 4.72 4.72 4.76 5.04 5.16 5.49 5.35 5.79 5.79 5.79 6.14 6.24 6.57 3.74 3.82 4.17 3.82 3.82 4.02 4.02 3.62 3.82 3.03 3.03 3.27 3.27 3.66 3.82 4.45 4.45 4.41 4.37 4.37 4.33 3.81 3.90 4.41 4.41 4.37 4.33 4.33 3.82 4.41 4.41 4.41 4.37 4.33 4.33 3.82 5.98 5.98 5.98 5.43 5.08 5.31 4.80 1/2×3 1/2×3 1/2×3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 9/16×3 9/16×3 9/16×3 9/16×3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5×2 5x2-1/2 5×3 5×1 5x1-1/4 5x1-1/2 5×2 5x2-1/2 5×3 5×1 5x1-1/4 5x1-1/2 5×2 5x2-1/2 5×3 6×1 6x1-1/4 6x1-1/2 6×2 6x2-1/2 6×3 6×4 6×1 6x1-1/4 6x1-1/2 6×2 6x2-1/2 6×3 6×4 6×1 6x1-1/4 6x1-1/2 6×2 6x2-1/2 6×3 6×4 8×1 8x1-1/4 8x1-1/2 8×2 8x2-1/2 8×3 8×4 27 ▪Ductile Iron ASTM A-536 Grade 65-45-12 ▪All grooved dimensions conform to ASME B1.20.1 ▪Finish available in standard orange paint or hot dipped galvanized (ASTM A-153) ▪Gasket: Grade E – EPDM with operating temperature of -30F to 230F (-34C to 110C) and is marked by a green stripe ▪Bolts are SAE J429 Grade 5 ▪Pressure rated up to 300psi ▪For current listing/approval details contact a Titus representative MECHANICAL TEES MECHANICAL TEE - GROOVED 31MG 38 44.5 44.5 38 44.5 50.8 38 44.5 50.8 38 44.5 50.8 63.5 64 80 38 44.5 50.8 63.5 70 70 89 53 64 80 92 44.5 50.8 63.5 70 70 89 60.3×33.7 60.3×42.4 60.3×48.3 73×33.7 73×42.4 73×48.3 76.1×33.7 76.1×42.4 76.1×48.3 88.9×33.7 88.9×42.4 88.9×48.3 88.9×60.3 108×60.3 108×76.1 114.3×33.7 114.3×42.4 114.3×48.3 114.3×60.3 114.3×73 114.3×76.1 114.3×88.9 133×48.3 133×60.3 133×76.1 133×88.9 139.7×42.4 139.7×48.3 139.7×60.3 139.7×73 139.7×76.1 139.7×88.9 42 42 42 47 47 47 48 48 48 55 55 55 55 62 62 65 65 65 65 65 65 65 74 74 74 74 77 77 77 77 77 77 120 120 120 143 143 143 143 143 143 158 158 158 158 172 172 181 181 181 181 181 181 181 205 205 205 205 219 219 219 219 219 219 NominalSizein/mm PipeO.D. Hole Dia.+0.13,-0 /+3.2,-0 AB Dimensions - in /mm 76 84 84 76 84 90 76 84 90 76 84 90 101 90 107 76 84 90 101 117 117 136 90 100 117 129 84 90 101 117 117 136 CD 72 72.5 72.5 78 78.5 78.5 79.5 80 80 85.5 86 86 87 92.5 92.5 98 99 99 99 99 99 99 105.5 105.5 105.5 105.5 112 112 113 113 113 113 M10×60 M10×60 M10×60 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×65 M12×70 M12×70 M12×70 M12×70 M12×70 M12×70 M12×70 M12×75 M12×75 M12×75 M12×75 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 Bolt Sizein/mm 50×25 50×32 50×40 65×25 65×32 65×40 65×25 65×32 65×40 80×25 80×32 80×40 80×50 100×50 100×65 100×25 100×32 100×40 100×50 100×65 100×65 100×80 125×40 125×50 125×65 125×80 125×32 125×40 125×50 125×65 125×65 125×80 1.50 1.75 1.75 1.50 1.75 2.00 1.50 1.75 2.00 1.50 1.75 2.00 2.50 2.52 3.15 1.50 1.75 2.00 2.50 2.76 2.76 3.50 2.09 2.52 3.15 3.62 1.75 2.00 2.50 2.76 2.76 3.50 2.375×1.327 2.375×1.669 2.375×1.9 2.875×1.327 2.875×1.669 2.875×1.9 3×1.327 3×1.669 3×1.9 3.5×1.327 3.5×1.669 3.5×1.9 3.5×2.375 4.25×2.375 4.25×3 4.5×1.327 4.5×1.669 4.5×1.9 4.5×2.375 4.5×2.875 4.5×3 4.5×3.5 5.25×1.9 5.25×2.375 5.25×3 5.25×3.5 5.5×1.669 5.5×1.9 5.5×2.375 5.5×2.875 5.5×3 5.5×3.5 1.65 1.65 1.65 1.85 1.85 1.85 1.89 1.89 1.89 2.17 2.17 2.17 2.17 2.44 2.44 2.56 2.56 2.56 2.56 2.56 2.56 2.56 2.91 2.91 2.91 2.91 3.03 3.03 3.03 3.03 3.03 3.03 4.72 4.72 4.72 5.63 5.63 5.63 5.63 5.63 5.63 6.22 6.22 6.22 6.22 6.77 6.77 7.13 7.13 7.13 7.13 7.13 7.13 7.13 8.07 8.07 8.07 8.07 8.62 8.62 8.62 8.62 8.62 8.62 2.99 3.31 3.31 2.99 3.31 3.54 2.99 3.31 3.54 2.99 3.31 3.54 3.98 3.54 4.21 2.99 3.31 3.54 3.98 4.61 4.61 5.35 3.54 3.94 4.61 5.08 3.31 3.54 3.98 4.61 4.61 5.35 2.83 2.85 2.85 3.07 3.09 3.09 3.13 3.15 3.15 3.37 3.39 3.39 3.43 3.64 3.64 3.86 3.90 3.90 3.90 3.90 3.90 3.90 4.15 4.15 4.15 4.15 4.41 4.41 4.45 4.45 4.45 4.45 3/8×2-3/8 3/8×2-3/8 3/8×2-3/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-5/8 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×2-3/4 1/2×3 1/2×3 1/2×3 1/2×3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 2×1 2x1-1/4 2x1-1/2 2-1/2x1 2-1/2x1-1 /4 2-1/2x1-1/2 2-1/2 x1 2-1/2x1-1/4 2-1/2x1-1/2 3×1 3x1-1/4 3x1-1/2 3×2 4×2 4x2-1/2 4×1 4x1-1/4 4x1-1/2 4×2 4x2-1/2 4x2-1/2 4×3 5x1-1/2 5×2 5x2-1/2 5×3 5x1-1/4 5x1-1/2 5×2 5x2-1/2 5x2-1/2 5×3 28 MECHANICAL TEES MECHANICAL TEE - GROOVED (CONTINUED) 31MG 44.5 50.8 63.5 70 70 89 64 80 92 104 111 44.5 50.8 63.5 70 70 89 114 114 44.5 50.8 63.5 70 70 89 114 63.5 70 70 89 114 114 141.3×42.4 141.3×48.3 141.3×60.3 141.3×73 141.3×76.1 141.3×88.9 159×60.3 159×76.1 159×88.9 159.0×108.0 159.0×114.3 165.1×42.4 165.1×48.3 165.1×60.3 165.1×73 165.1×76.1 165.1×88.9 165.1×108 165.1×114.3 168.3×42.4 168.3×48.3 168.3×60.3 168.3×73 168.3×76.1 168.3×88.9 168.3×114.3 219.1×60.3 219.1×73 219.1×76.1 219.1×88.9 219.1×108 219.1×114.3 77 77 77 77 77 77 91 91 91 91 91 94 94 94 94 94 94 94 94 97 97 97 97 97 97 97 125 125 125 125 125 125 219 219 219 219 219 219 233 233 233 233 233 248 248 248 248 248 248 248 248 248 248 248 248 248 248 248 322 322 322 322 322 322 NominalSizein/mm PipeO.D. Hole Dia.+0.13,-0/+3.2,-0 AB Dimensions - in /mm 84 90 101 117 117 136 100 117 129 143 153 84 90 101 117 117 136 162 162 84 90 101 117 117 136 162 101 117 117 136 162 162 CD 112 112 113 113 113 113 118 118 118 119.5 119.5 125 125 125 125 125 125 129 129 125 125 125 127 127 127 129 152 154 154 154 156 156 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M14×75 M14×75 M14×75 M14×75 M14×75 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M16×85 M20×90 M20×90 M20×90 M20×90 M20×90 M20×90 Bolt Sizein/mm 125×40 125×40 125×50 125×65 125×65 125×80 150×50 150×65 150×80 150×100 150×100 150×32 150×40 150×50 150×65 150×65 150×80 150×100 150×100 150×32 150×40 150×50 150×65 150×65 150×80 150×100 200×50 200×65 200×65 200×80 200×100 200×100 1.75 2.00 2.50 2.76 2.76 3.50 2.52 3.15 3.62 4.09 4.37 1.75 2.00 2.50 2.76 2.76 3.50 4.49 4.49 1.75 2.00 2.50 2.76 2.76 3.50 4.49 2.50 2.76 2.76 3.50 4.49 4.49 5.563×1.669 5.563×1.9 5.563×2.375 5.563×2.875 5.563×3 5.563×3.5 6.25×2.375 6.25×3 6.25×3.5 6.25×4.25 6.25×4.5 6.5×1.669 6.5×1.9 6.5×2.375 6.5×2.875 6.5×3 6.5×3.5 6.5×4.25 6.5×4.5 6.625×1.669 6.625×1.9 6.625×2.375 6.625×2.875 6.625×3 6.625×3.5 6.625×4.5 8.625×2.375 8.625×2.875 8.625×3 8.625×3.5 8.625×4.25 8.625×4.5 3.03 3.03 3.03 3.03 3.03 3.03 3.58 3.58 3.58 3.58 3.58 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.82 3.82 3.82 3.82 3.82 3.82 3.82 1.92 1.92 1.92 1.92 1.92 1.92 8.62 8.62 8.62 8.62 8.62 8.62 9.17 9.17 9.17 9.17 9.17 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 9.76 12.68 12.68 12.68 12.68 12.68 12.68 3.31 3.54 3.98 4.61 4.61 5.35 3.94 4.61 5.08 5.63 6.02 3.31 3.54 3.98 4.61 4.61 5.35 6.38 6.38 3.31 3.54 3.98 4.61 4.61 5.35 6.38 3.98 4.61 4.61 5.35 6.38 6.38 4.41 4.41 4.45 4.45 4.45 4.45 4.65 4.65 4.65 4.70 4.70 4.92 4.92 4.92 4.92 4.92 4.92 5.08 5.08 4.92 4.92 4.92 5.00 5.00 5.00 5.08 5.98 6.06 6.06 6.06 6.14 6.14 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 9/16×3 9/16×3 9/16×3 9/16×3 9/16×3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/3 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5/8×3-1/2 5x1-1/2 5x1-1/2 5×2 5×2-1/2 5×2-1/2 5×3 6×2 6x2-1/2 6×3 6×4 6×4 6×1-1/4 6x1-1/2 6×2 6×2-1/2 6×2-1/2 6×3 6×4 6×4 6x1-1/4 6x1-1/2 6×2 6x2-1/2 6x2-1/2 6×3 6×4 8×2 8x2-1/2 8x2-1/2 8×3 8×4 8×4 29 Fig. 4L TOLCO sway brace attachment Function: For bracing pipe against sway and seismic disturbances. Fig. 4L is the “braced pipe” attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a 1"–2" NPS “bracing pipe” and a TOLCO structural attachment component to form a complete bracing assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer’s installation instructions. To install: Place the Fig. 4L over the pipe to be braced and tighten down the break-off nuts (note: apply between 50-60 lb. ft. of torque). Tighten the jaw component side nut first until the hex head portion breaks off to verify correct installation torque and then repeat for other side. Next, place the Fig. 4L onto the “bracing pipe” so that there is no more than an 1/8" gap between the end of the bracing pipe and the back of the jaw. Tighten break-off head bolt until the hex head breaks off to verify correct installation torque (note: apply between 36-40 lb. ft. of torque on PLN or EG or 45-50 lb. ft. of torque on HDG or SS Fig. 4L). Pivot jaw for correct angle and attach to structure using TOLCO brand transitional attachment and structural attachment. Note: Break off nut is only for plain and electrogalvanized finish while standard hex nut is for hot dip galvanized and stainless steel finish. Torque requirements for standard hex nut is a minimum of 50 lbs/ft. and a maximum of 52 lbs/ft. Follow us on social media to get the latest product and support information. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 13201 Dahlia Street, Suite 200 Fontana, CA 92337 United States Phone: 800-851-7415 © 2021 Eaton All Rights Reserved Printed in USA Publication No. IL309015EN March 24, 2021 B-Line Division Eaton.com/tolco Eaton is a registered trademark. All other trademarks are property of their respective owners. Seismic Instruction sheet 4-Way Riser Brace With Plain & Electrogalvanized Finish With Hot Dip Galvanized & Stainless Steel Finish Lateral Brace Max UL Rated Load when used as a lateral brace Max UL Rated Load when used as a longitudinal brace Longitudinal Brace Pipe size Rated load SS Rated load 1" – 4" 1000 lbs.**1000 lbs. 5"– 6"*1600 lbs.**1600 lbs. 8"*2100 lbs.— Pipe size Rated load SS Rated load 1" – 11/2"1000 lbs.— 2"1600 lbs.— 21/2"– 8"***2000 lbs.**2100 lbs. *Only UL listed for use with a 1" brace pipe ** Stainless steel (Fig. 4LS) is only offered for 4" and 6" size pipe 21/2" - 8" 2000 lbs. ** Stainless steel (Fig. 4LS) is only offered for 4" and 6" size pipe *** Note that the Fig. 4L-4" and 5" are only UL listed for use with 1" thru 11/2" brace pipes. Fig. 980 - TOLCO Universal swivel sway brace attachment -3/8"-16 to 3/4"-10 rods Fig. 980H - TOLCO Universal swivel sway brace attachment -7/8"-9 to 11/4 "-7 B-LINE SERIES Size Range: One size fits bracing pipe 1" (25mm) thru 2" (50mm), Eaton B-Line series 12 gauge (2.6mm) channel. Material: Carbon steel Function: The Fig. 980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the a 1" through 2" “bracing pipe” and TOLCO “brace pipe” attachment to form a complete bracing assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer’s installation instructions. Features: A concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break-off bolt head helps assure verification of proper installation. To install: Place the Fig. 980 onto the “bracing pipe” so that there is no more than an 1/8" gap between the end of the bracing pipe and the back of the jaw. Tighten the set screw until the head breaks off (hint: apply between 36-40 lb. ft. of torque). When using in combination with a Fig. 825A, Fig. 825, Fig. 828, or Fig. 906, refer to those instruction sheets, otherwise select an anchor that is sized appropriately for the intended use and follow anchor manufacturer's instructions regarding structural thickness and embedment requirements. The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13. Once the anchor is installed per manufacturer’s direction, secure the Fig. 980 to the anchor. Attachment can pivot to allow for proper brace angle adjustment. Finish: Plain, electro-galvanized or stainless steel. Follow us on social media to get the latest product and support information. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 13201 Dahlia Street, Suite 200 Fontana, CA 92337 United States Phone: 800-851-7415 © 2020 Eaton All Rights Reserved Printed in USA Publication No. IL309006EN September 2020 B-Line Division Eaton.com/tolco Eaton is a registered trademark. All other trademarks are property of their respective owners. A B D**Max. Design Load (cULus) lbs./(kN) Max. Design Load*** (FM)Approx.Wt./100 Catalog #in.(mm)in.(mm)in.(mm)30°-44° lbs./(kN) 45°-59° lbs./(kN) 60°-74° lbs./(kN) 75°-90° lbs./(kN)lbs.(kg) *980-3/8 49/16 (114.9) 21/16 (52.4) 7/16 (11.1)1600 (7.12) 2370 (10.54) 2790 (12.41) 3360 (14.94) 3750 (16.68) 149 (67.6) *980-1/2 9/16 (14.3)2100 (9.34)148 (67.1) *980-5/8 11/16 (17.5)2100 (9.34)147 (66.7) *980-3/4 13/16 (20.6)2100 (9.34)146 (66.2) 980H-7/8 63/4 (171.4) 31/2 (88.9) 15/16 (23.8)402 (182.3) 980H-1 11/16 (27.0)400 (181.4) 980H-11/8 13/16 (30.2)397 (180.1) 980H-11/4 15/16 (33.3)390 (176.9) Seismic Instruction sheet * Sizes available in stainless steel (980S-3/8, 980S-1/2, 980S-5/8, and 980S-3/4) and have the same UL rating as what is listed. ** Mounting attachment hole size. *** Installed with 1" or 11/4 "schedule 40 brace pipe. A D BB D A 980 OPM Component of State of California OSHPD Approved Seismec Restraints System A B D B D A 980H Longitudinal Brace Lateral Brace Brace Fig. 980 Fig. 980 with Fig. 4B shown Fig. 1001 Fig. 980 Fig. *980H is not UL Listed or FM Approved OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 156 www.tolco.com Revision 12/3/2008 Size Range — Pipe size to be braced: 21⁄2" thru 8" IPS.* Pipe size used for bracing: 1" and 11⁄4" Schedule 40 IPS. Material — Carbon Steel Function — For bracing pipe against sway and seismic distur- bance. The pipe attachment component of a sway brace system: The Fig. 1001 is used in conjunction with a TOLCO 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a com- plete sway brace assembly. Features — Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of brac- ing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note — Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note — The Fig. 1001 is precision manufactured to perform its function as a critical component of a complete brac- ing assembly. To ensure performance, the UL Listing requires that the Fig. 1001 must be used only with other TOLCO bracing products. The Fig 1001 is not intended for use with the Fig. 907 4-Way Longitudinal Brace Attachment. Fig. 1001 - Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Maximum Design Load Sch. 7 - 1600 lbs. Sch. 10 & 40 w/1" Brace Pipe - 2015 lbs. Sch. 10 & 40 w/11⁄4" Brace Pipe - 2765 lbs. FM Approved Design Loads* 2½ " - 2400 lbs. 3" - 4" - 2500 lbs. 5" - 8" - 1500 lbs.